RecordWell Data

Seminole Pool & Tennis Club

5948 SCHUMANN DR, Fitchburg, WI 53711 · Dane County

17cited violations
0serious tier
12inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2010-00234
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026160
2025170
2024140
2021100
2019100
2018100
2017100
2016100
2015100
2014100
2013100
2012100

Inspections

  1. Aug 17, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Complete checklist and mai

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot demostrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: Head guard completed form

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency is not in compliance with ATCP 76.18(3). Both basins share disinfection system and some days only the main pool is tested.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED (Pf)

      The maximum patron load is not posted in the wading pool area.

      Correction: Post the maximum patron load conspicuously near each pool.

      Code ATCP 76.29(1)(e)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Gauze roller bandage and adhesive tape are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      In pump room effluent pressure gauge is non functional.

      Correction: Properly locate, intall, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

  2. Jun 17, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency is not in compliance with ATCP 76.18(3). Both basins share a disinfectant system, only the main pool basin is tested.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC rewrote patron load on Corrected on site

      26c - PATRON LOAD - WADING POOLS (Pf)

      The posted maximum patron load is not posted, the number written has faded.

      Correction: Calculate and post the maximum patron load in compliance with ATCP 76.25(2).

      Code ATCP 76.25(2)(c)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      Biohazard kit is missing several items.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Equipment is not maintained and repaired as necessary. 1. Flow meter bobber is stuck on the bottom of reader. 2. Effluent gauge for sand filters is non operational.

      Correction: Properly locate, install, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 10, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken: PIC added patron load to s Corrected on site

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: PIC moved signage to post

      27e - SIGNAGE - POOL RULES

      The pool rules signage is resting on deck in the main pool enclosure area.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b) posted in a conspicuous place.

      Code ATCP 76.29(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      1. A screw is missing on the main drain. 2. No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Jul 14, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  5. Jul 22, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jun 11, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 9, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 27, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 8, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 10, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jun 10, 2013 Routine Inspection · Reinspection Required

    No violations cited.

  12. Jun 18, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.