RecordWell Data

Staybridge Suites - Madison East

3301 City View DR, Madison, WI 53718 · Dane County

23cited violations
0serious tier
7inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2022-00843
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025120
20242160
2023320
2022130

Inspections

  1. Nov 26, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagent #9 for the total alkalinity test is empty.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Gauze roller bandage and adhesive tape are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

  2. Oct 29, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      05b - WATER LEVEL - Not Corrected

      The pool water level is not adequate for continuous effective surface skimming. The water level is too high; the water level is above the skimmer opening.

      Correction: Adjust the water level until the skimming of the water surface is adequate.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Pool exterior enclosure do Repeat Corrected on site

      34c - DOOR/GATE - Not Corrected

      A pair of doors to the pool enclosure are not self-closing and self-latching. The left door does not fully close even though this door has a self-closing mechanism and the door does not self-latch. The right door does not self-close or self-latch.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable. Close the pool.

      Code ATCP 76.34(4)

  3. Aug 2, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace the skimmer weir or install a floating weir.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      05b - WATER LEVEL

      The pool water level is not adequate for continuous effective surface skimming. The water level is too high; the water level is above the skimmer opening.

      Correction: Adjust the water level until the skimming of the water surface is adequate.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagent R-0003 has a manufacturer best by date of 01/2024. The color comparator is dirty.

      Correction: Replace reagents as recommended by the manufacturer. Clean or replace the color comparator.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for pH, free chlorine, combined chlorine and total alkalinity are not in compliance with ATCP 76.18(1) & (3). These water tests are not being completed.

      Correction: Perform water testing in accordance with ATCP 76.18(1) & (3). Test pH and free chlorine level at least once a day. Test combined chlorine level at least twice a week. Test total alkalinity at least once a week.

      Code ATCP 76.18(1) & (3)

    • Not serious Action taken: The pool was closed and th

      23d - NO RESPONSIBLE SUPERVISOR

      No responsible supervisor is available.

      Correction: The pool must be closed until a responsible supervisor is available to fulfill the responsibilities.

      Code ATCP 76.21

    • Not serious Action taken: Pool closed and doors to t

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately. Close the pool.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Gauze pads, adhesive bandages, gauze roller bandage, adhesive tape, elastic bandages, and instant cold packs are missing from the first aid kit. The eye wash solution in the first aid kit is expired.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      There is only one durable blankets in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA

      The pool was not closed under the following conditions: -A pair of doors to the pool enclosure are not self-closing and self-latching. -There is no responsible supervisor available. -There is a missing screw on one of the main drain covers. -The emergency phone is nonfunctional.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN

      The drinking fountain is not functional.

      Correction: Repair the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken: The pool was closed and th

      31b - EQUIPMENT NOT MAINTAINED

      There is a missing screw on a main drain cover.

      Correction: Repair and maintain all equipment. Close the pool.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken: Pools closed and pool encl

      34c - DOOR/GATE

      A pair of doors to the pool enclosure are not self-closing and self-latching. The left door does not fully close even though this door has a self-closing mechanism and the door does not self-latch. The right door does not self-close or self-latch.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable. Close the pool.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Apr 25, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken: The operator acknowledge h

      14f - NO DISINFECTANT FEEDER - Not Corrected

      The pool is not being automatically and continually disinfected via a disinfectant feeder.

      Correction: The pool must be closed and a disinfectant feeder, approved by the department of commerce, must be installed before the facility can re-open.

      Code ATCP 76.14(1)

  5. Apr 3, 2023 Re-Inspection · No Reinspection Required

    No violations cited.

  6. Mar 24, 2023 Re-Inspection · Reinspection Required
    • Not serious Action taken: Operator state testing poo Repeat

      20c - WATER TESTING - POOLS - Not Corrected

      Water tests are not accurate and not in compliance with ATCP 76.18(1). Operator stated the records are being filled in without completing the tests for free chlorine, combined chlorine, pH, and total alkalinity. No water test records available for March 2023.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

  7. Nov 11, 2022 Pre-Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Phone line corrected. Now Corrected on site

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work. Phone has busy signal and is not able to dial out or connect to the front desk.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN

      The drinking fountain is not functional or not turned on.

      Correction: Repair or turn on drinking fountain.

      Code ATCP 76.33(1)(g)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.