  1. May 13, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Pool closed by operator. P Repeat

      26n - TELEPHONE - NOT WORKING (P) - Not Corrected

      Emergency phone rings front desk and does not work.

      Correction: Provide a functional emergency telephone immediately. Post the emergency numbers near or attached to the designated emergency phone. Ensure calls are picked up within 2 rings, staff are trained on emergency procedures, do not have distractive duties, and do not use cordless phone to leave desk. Post emergency numbers and address at front desk.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Monthly operating record does not include monthly pump and safety checks.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: Remodel expected Summer 20

      29b - BASIN MAINTENANCE AND REPAIR - Not Corrected

      The pool basin is discolored.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  2. May 11, 2026 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf) - Not Corrected

      Water testing was not completed daily for each day the whirlpool was open.

      Correction: Perform water testing in accordance with ATCP 76.18(2).

      Code ATCP 76.18(2)

    • Not serious Action taken: Poster provided with email

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Pool closed by operator. P Corrected on site

      26n - TELEPHONE - NOT WORKING (P) - Not Corrected

      Emergency phone rings front desk and does not work.

      Correction: Provide a functional emergency telephone immediately. Post the emergency numbers near or attached to the designated emergency phone. Ensure calls are picked up within 2 rings, staff are trained on emergency procedures, do not have distractive duties, and do not use cordless phone to leave desk. Post emergency numbers and address at front desk.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Monthly operating record does not include monthly pump and safety checks.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: Remodel expected Summer 20

      29b - BASIN MAINTENANCE AND REPAIR - Not Corrected

      The pool basin is discolored.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Corrected on site

      32d - CARBON MONOXIDE ALARMS (P) - Not Corrected

      There is no carbon monoxide alarm in the indoor pool area with a fuel burning appliance in the adjacent equipment room.

      Correction: Install functioning carbon monoxide alarm in the pool area.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No pump curve available for recirculation pump.

      Correction: Maintain recirculation pump curve onsite.

      Code ATCP 76.38

  3. Mar 26, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)

      Water testing was not completed daily for each day the whirlpool was open.

      Correction: Perform water testing in accordance with ATCP 76.18(2).

      Code ATCP 76.18(2)

    • Not serious Action taken: Poster provided with email

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Pool closed by operator. P Corrected on site

      26n - TELEPHONE - NOT WORKING (P)

      Emergency phone rings front desk and does not work.

      Correction: Provide a functional emergency telephone immediately. Post the emergency numbers near or attached to the designated emergency phone. Ensure calls are picked up within 2 rings, staff are trained on emergency procedures, do not have distractive duties, and do not use cordless phone to leave desk. Post emergency numbers and address at front desk.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf)

      Monthly operating record does not include monthly pump and safety checks.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: Remodel expected Summer 20

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin is discolored.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in the indoor pool area with a fuel burning appliance in the adjacent equipment room.

      Correction: Install functioning carbon monoxide alarm in the pool area.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No pump curve available for recirculation pump.

      Correction: Maintain recirculation pump curve onsite.

      Code ATCP 76.38

  4. Jan 17, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Muriatic acid safety data

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility including muriatic acid, sodium hydrogen sulfite, calcium chloride taylor test kit reagents and defoaming agent.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Video training provided wi

      13c - DISINFECTANT FEEDER - NOT ELECTRICALLY CONNECTED

      Operator unable to demonstrate that the disinfectant feeder pump is electrically connected to the recirculation pump control circuit.

      Correction: Ensure disinfectant feeder is electrically connected to the recirculation pump so it cannot keep running when the recirculation pump is turned off. Obtain training to demonstrate system is electrically connected.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 879 mV at the time of the inspection. System alarm flashing.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.6ppm

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a non-chlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken: Factsheet provided with em

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE

      Combined chlorine and alkalinity is not tested at a frequency specified with ATCP 76.18(2). Electronic ORP monitor is improperly functioning. Increase testing frequency for pH and disinfectant in accordance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test pH and disinfectant 4/day, combined chlorine 1/day and alkalinity 1/week.

      Code ATCP 76.18(2)

    • Not serious Action taken:

      28d - MONTHLY REPORTS AVAILABLE

      Pump curve and CDC fecal response procedure are not available for review.

      Correction: Keep records available for review.

      Code ATCP 76.32(3)

    • Not serious Action taken:

      34a - GATES NOT MAINTAINED

      The gate or door to the pool enclosure from the courtyard is not being maintained. Mechanism requires repair. Parts ordered per operator. Door temporarily locked. Email sanitarian when repair is complete.

      Correction: Repair and maintain the gate or door.

      Code ATCP 76.34(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Covers appear secure and intact.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jun 15, 2023 Pre-Inspection · No Reinspection Required
    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area. There was only 1 rescue blanket available in the first aid kit.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken: self-latching bar is on or

      34c - DOOR/GATE

      The courtyard door to the pool enclosure is self-closing and lockable, however, the self-latching mechanism is missing.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.