  1. Apr 15, 2026 Routine · 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is not being recorded or monitored electronically. After discussion with pool staff, the pool is being tested manually for the ORP but there is no record keeping to show that the orp is between 650-900 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log or information sheet that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. I was able to confirm the installation date with employee and reviewing last year's inspection report.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  2. Apr 30, 2025 Re-inspection · No items found

    No violations cited.

  3. Apr 16, 2025 Routine · 2 critical, 7 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. The silver bead is stuck on the flow meter gauge and the flow meter does not change on the electric monitoring control device.

      Correction: Adjust or repair the flow meter gauge and the electric monitoring control device.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 961 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY INSTALLLED

      The pool equipment is not properly installed. The pool ladder and right railing connecting to the ladder is loose and not tightly secured. The ladder moves around with ease being wobbly and is not tightly secured.

      Correction: Ensure that the pool equipment is properly installed and secured.

      Code ATCP 76.33(1)(e)2. - INSTALLATION OF POOL EQPT.

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-INSTALLATION DATE

      The VGBA log or other proof does not indicate drain cover installation date for the main drain covers in the pool.

      Correction: Indicate in the log of drain cover installation date.

      Code ATCP 76.38(2)(b)5. - INSTALL DATE

    • Serious Critical Repeat

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed and is not performing or recording the monthly interlock testing.

      Correction: Ensure that operator can describe how monthly testing is performed and is performing and recording the monthly interlock testing results

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided within 300 feet walking distance of the pool.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  4. Apr 22, 2024 Re-inspection · 1 critical, 4 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The Oxygen Reduction Potential (ORP) is not being maintained in operating condition, the readout is not functioning on the electronic monitoring system and cannot be read.

      Correction: Adjust or repair the ORP so a proper reading can be seen.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 31.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is not readable and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Serious Critical Repeat

      PH

      The pH is 6.6. Pool was closed down immediately during inspection so pH levels can be brought back up to 7.2 at the minimum.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  5. Apr 22, 2024 Re-inspection 2 · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The Oxygen Reduction Potential (ORP) is not being maintained in operating condition, the readout is not functioning on the electronic monitoring system and cannot be read.

      Correction: Adjust or repair the ORP so a proper reading can be seen.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is not readable and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

  6. Apr 16, 2024 Routine · 3 critical, 12 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is roughly 50/50. It was observed the skimmer level was set halfway so only 50% of the water was recirculating through the skimmers.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer. Skimmer level was adjusted so roughly 80% of the recirculation flow is through the skimmers and 20% through the main drain.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The Oxygen Reduction Potential (ORP) is not being maintained in operating condition, the readout is not functioning on the electronic monitoring system and cannot be read.

      Correction: Adjust or repair the ORP so a proper reading can be seen.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 31.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is not readable and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Multiple reagents have expired in 2/2024, 2/2023, and 3/2023 and are being used to test the pool.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing the following items: guaze pads, eye wash, adhesive bandages, and resuscitation pocket face mask.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Corrected on site

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises. Copy was provided during inspection.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical

      AIR MOVEMENT

      Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. Excess condensation is observed creating a large pool of water in the chemical/filtration pump room.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. Add a longer plumbing pipe to drain inside pump/chemical room so water is properly drained and does not create large puddles of water.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Serious Critical

      CHEMICAL STORAGE LOCATION

      Multiple containers of chemicals were observesd stored in a large puddle of water caused by condensation from the heater and are not stored in a clean, dry, well-ventilated room.

      Correction: Store all chemicals in clean, dry, well-ventilated, locked area away from flammables, incompatible chemicals and heat sources. Make sure to store chemicals in a dry location.

      Code ATCP 76.12 (2)(b) - CHEMICAL STORAGE LOCATION

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed and monthly testing is not currently being performed for the interlock testing.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical

      PH

      The pH is 6.6. Pool was closed down immediately during inspection so pH levels can be brought back up to 7.2 at the minimum.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  7. May 1, 2023 Routine · 3 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical

      PERMIT NOT POSTED

      The permit is not posted in a place visible to the public.

      Correction: Post the permit in public view.

      Code ATCP 76.05(7)

    • Not serious Non-critical

      EMERGENCY CONTACT PHONE NUMBERS NOT POSTED

      The facility's location/address is not posted near the emergency telephone. Facility does list dial 0 for an emergency.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code [C] ATCP 76.26(2)

    • Not serious Non-critical

      FIRST AID SUPPLIES MISSING

      Eyewash is expired and gauze roller bandage, adhesive bandage, traingular bandage, tweezers, instant cold packs, and resuscitation mask are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code [C] ATCP 76.27(1)

    • Serious Critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 55 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Serious Critical

      COMBINED CHLORINE

      The combined chlorine is 1.7.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer. Pool will be closed and a chlorine product will be used to reduce the combined chlorine level back to at or below 0.8.

      Code ATCP 76.14(4)(e)

    • Serious Critical Repeat

      SKIMMER/MAIN DRAIN RATIO INCORRECT

      The skimmer to main drain flow ratio is not set correctly.

      Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.

      Code [A] ATCP 76.11(2)(a)

Source: City of Appleton Health Department. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.