Super 8 Motel (ashland)
1610 W LAKESHORE DR, Ashland, WI 54806 · Ashland County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- Ashland County Health & Human Services
- License / ID
- KTUL-CM6SUD
- Status
- Permitted
- Official record
- Ashland County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 1 |
| 2025 | 2 | 9 | 5 |
| 2024 | 1 | 5 | 1 |
| 2023 | 2 | 5 | 1 |
Inspections
-
Feb 9, 2026 Routine · 1 critical
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-FAILURE TO MEET 76.16
The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. Combined Chlorine at 1.6 today and in records 0.4 with no breakpoint chlorination or drain and refill for the past 7 days.
Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16. Managment closed the hot tub and pool operator refilled with fresh water instead of breakpoint chlorination.
Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16
-
Serious
Critical
Corrected on site
-
Sep 30, 2025 Re-inspection · 2 critical, 1 repeat
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 3ppm for chorine in a whirpool. Today the free chlorine level is measured to be 1.2ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
GATES AND DOORS-LATCHING
The gate or door does not latch or self lock.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Serious
Critical
-
Aug 26, 2025 Routine · 3 critical, 4 non-critical, 2 repeat
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
PH
The pH is 6.8
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
GATES AND DOORS-LATCHING
The gate or door does not latch or self lock.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
-
Sep 11, 2024 Routine · 1 critical, 4 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
INTERLOCK LOG-MADE AVAILABLE
Log of interlock testing not made available to the department or its agent upon request.
Correction: Make interlock test log available to the department or its agent upon request.
Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. [Describe].
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. [Describe].
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Not serious
Non-critical
Repeat
-
Oct 4, 2023 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
INTERLOCK LOG-MADE AVAILABLE
Log of interlock testing not made available to the department or its agent upon request.
Correction: Make interlock test log available to the department or its agent upon request.
Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Not serious
Non-critical
-
Jul 11, 2023 Routine · No items found
No violations cited.
Source: Ashland County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.