  1. Feb 9, 2026 Routine · 1 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Turnover rate was calulated to be 7.1 hours. The Flowmeter was at approximately 28 gallons/min and the pool is 12,000 gallons.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours or less. CPO called in to fix the flow rate to be at least 33 gpm for a turnover rate of 6 hours or less for this pool.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

  2. Aug 26, 2025 Routine · 3 non-critical, 2 repeat
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. [Describe].

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  3. Sep 11, 2024 Routine · 1 critical, 4 non-critical
    • Not serious Non-critical

      INTERLOCK LOG-MADE AVAILABLE

      Log of interlock testing not made available to the department or its agent upon request.

      Correction: Make interlock test log available to the department or its agent upon request. Template Provided.

      Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. Template provided- This is a new requirment with the new pool code.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available and staff could not determine correctly what to do if a biohazard event occurs.

      Correction: Provide a biohazard kit for the pool and train all employees on what to do if a biohazard event happens.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. Template log provided.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. Door is not self locking or latching.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

  4. Oct 4, 2023 Routine · No items found

    No violations cited.

  5. Jul 11, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      DIRECTION OF FLOW NOT LABELED

      The water treatment system piping is not marked with a permanent label indicating direction of flow on every pipe. Most are marked already.

      Correction: Mark the water treatment system piping to indicate direction of flow on all pipes.

      Code ATCP 76.11(5m)