RecordWell Data

Pub & Inn (the) - Swimming Pool

641 MAIN ST, La Pointe, WI 54850 · Ashland County

13cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
Ashland County Health & Human Services
License / ID
HSAT-7QXEYB
Status
Permitted
Phone
(715) 747-6315
Official record
Ashland County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026132
2025120
2023280

Inspections

  1. Jun 16, 2026 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 100.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower. Pool operator states the levels are being decreased daily by draining and putting in fresh water.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. There is a non-functioning light.

      Correction: Correct the hazardous condition by fixing the light. Do not allow swimming once it is dark enough to cause a dark spot in the pool due to the damaged/defective light. Corrective action: pool not open once it is dark out.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical Corrected on site

      GATES AND DOORS-SELF-CLOSING

      The back gate does not self-close.

      Correction: Provide a self-closing gate or door. You can add a spring or similar to the door to get it to self close and latch. This is to prevent it from being left open. During inspection a bungie cord added to the door to create a self closing door with latch.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

  2. Jun 17, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. Will email to sanitarian.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. Information not on a log. CPO is going to find the information and fill out the log. Drain covers were replaced May 2025.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  3. Jun 19, 2023 Follow Up · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      DIRECTION OF FLOW NOT LABELED

      The water treatment system piping is not marked with a permanent label indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Non-critical Repeat

      FIRST AID KIT UNAVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area. If inside provide a sign with where to find it.

      Code [A] ATCP 76.27(1)

    • Not serious Non-critical Repeat

      GATES NOT MAINTAINED

      The gate or door to the pool enclosure is not being maintained. Damaged from yard maintinence-to be repaired ASAP

      Correction: Maintain the gate or door in accordance with ATCP 76.34(2).

      Code [A] ATCP 76.34(2)

    • Not serious Non-critical Repeat

      SKIMMER COVERS NOT SECURE

      Skimmer covers are not securely seated on the deck.

      Correction: Secure covers so they are not easily removed.

      Code [C] ATCP 76.11(2)(b)

  4. Jun 8, 2023 Routine · 4 non-critical
    • Not serious Non-critical

      DIRECTION OF FLOW NOT LABELED

      The water treatment system piping is not marked with a permanent label indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Non-critical

      FIRST AID KIT UNAVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area. If inside provide a sign with where to find it.

      Code [A] ATCP 76.27(1)

    • Not serious Non-critical

      GATES NOT MAINTAINED

      The gate or door to the pool enclosure is not being maintained. Damaged from yard maintinence-to be repaired ASAP

      Correction: Maintain the gate or door in accordance with ATCP 76.34(2).

      Code [A] ATCP 76.34(2)

    • Not serious Non-critical

      SKIMMER COVERS NOT SECURE

      Skimmer covers are not securely seated on the deck.

      Correction: Secure covers so they are not easily removed.

      Code [C] ATCP 76.11(2)(b)

Source: Ashland County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.