RecordWell Data

Americinn Motel

2906 PIONEER AVE S, Rice Lake, WI 54868 · Barron County

54cited violations
11serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Barron County Department of Health & Human Services
License / ID
PGAN-DJTRWG
Status
Permitted
Phone
(715) 234-8060
Official record
Barron County Department of Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
202535411

Inspections

  1. Nov 14, 2025 Pre-inspection Follow Up · 3 critical, 13 non-critical, 16 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      CYANURIC ACID USE LIMITATION

      Cyanuric acid has been used in an indoor pool.

      Correction: Discontinue use of Cyanuric acid in an indoor pool, therapy pool, or whirlpool.

      Code ATCP 76.14 (2)(c) - CYANURIC USE RESTRICTION

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The facility is using the Color Q Test kit for checking the pool water

      Correction: Puchase an approved testing kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents for Taylor Test kit are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BREAKPOINT CHLORINATION

      The operator did not record the following on the operating report: The dates breakpoint chlorination was completed.

      Correction: Record the following on the operating report, dates when breakpoint chlorination was completed.

      Code ATCP 76.32(1)(c) - BREAKPOINT CHLOR

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical Repeat

      OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT

      The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT

    • Not serious Non-critical Repeat

      SOAP-PROVIDED

      Soap not provided in permanently-installed dispensing device in the shower.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. There are cracks in the pool deck near the stair entrance to the pool.

      Correction: Maintain pool deck area in good repair . Repair the pool deck around the steps into the pool.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical Repeat

      RECIRCULATION SYSTEM CONTINUOUS OPERATION

      The pool recirculation system has a pump that is 2.0 hp. The DSPS approved plans for this pool has a 1.5 hp pump.

      Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.

      Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O

    • Serious Critical Repeat

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical Repeat

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck.

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

  2. Sep 16, 2025 Pre-inspection Follow Up · 3 critical, 13 non-critical, 16 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      CYANURIC ACID USE LIMITATION

      Cyanuric acid has been used in an indoor pool.

      Correction: Discontinue use of Cyanuric acid in an indoor pool, therapy pool, or whirlpool.

      Code ATCP 76.14 (2)(c) - CYANURIC USE RESTRICTION

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The facility is using the Color Q Test kit for checking the pool water

      Correction: Puchase an approved testing kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents for Taylor Test kit are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BREAKPOINT CHLORINATION

      The operator did not record the following on the operating report: The dates breakpoint chlorination was completed.

      Correction: Record the following on the operating report, dates when breakpoint chlorination was completed.

      Code ATCP 76.32(1)(c) - BREAKPOINT CHLOR

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical Repeat

      OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT

      The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT

    • Not serious Non-critical Repeat

      SOAP-PROVIDED

      Soap not provided in permanently-installed dispensing device in the shower.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. There are cracks in the pool deck near the stair entrance to the pool.

      Correction: Maintain pool deck area in good repair . Repair the pool deck around the steps into the pool.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical Repeat

      RECIRCULATION SYSTEM CONTINUOUS OPERATION

      The pool recirculation system has a pump that is 2.0 hp. The DSPS approved plans for this pool has a 1.5 hp pump.

      Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.

      Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O

    • Serious Critical Repeat

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical Repeat

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck.

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

  3. Aug 29, 2025 Pre-inspection · 5 critical, 17 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is 100% open on both.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer. Corrective action: skimmer was changed to 80% open and main drain was changed to 20% open

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter and gauge has been removed from the piping.

      Correction: Install a flowmeter and gauge

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      CYANURIC ACID USE LIMITATION

      Cyanuric acid has been used in an indoor pool.

      Correction: Discontinue use of Cyanuric acid in an indoor pool, therapy pool, or whirlpool.

      Code ATCP 76.14 (2)(c) - CYANURIC USE RESTRICTION

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      TEST KIT APPROVED

      The facility is using the Color Q Test kit for checking the pool water

      Correction: Puchase an approved testing kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents for Taylor Test kit are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Corrected on site

      MAX PATRON LOAD POOL

      The pool with a shallow end and a deep end exceeds maximum patron load or maximum patron load posted is incorrect.

      Correction: Calculate the maximum patron load to provide at least 15 square feet per patron in the shallow portion and 25 square feet per patron in the deep portion and do not allow maximum patron load to be exceeded. Corrective action: The posted sign stating 40 as the maximum was updated to 36

      Code ATCP 76.25(2)(a) - POOL

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      OPERATING REPORTS-BREAKPOINT CHLORINATION

      The operator did not record the following on the operating report: The dates breakpoint chlorination was completed.

      Correction: Record the following on the operating report, dates when breakpoint chlorination was completed.

      Code ATCP 76.32(1)(c) - BREAKPOINT CHLOR

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT

      The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT

    • Not serious Non-critical

      SOAP-PROVIDED

      Soap not provided in permanently-installed dispensing device in the shower.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

    • Not serious Non-critical Corrected on site

      HAND DRYING

      Hand drying device not provided.

      Correction: Provide individual towels in dispensers or hot air dryers at hand washing sinks. Corrective action: paper towel dispenser was restocked with paper towels

      Code ATCP 76.33 (2)(f) - HAND DRY DEVICE

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. There are cracks in the pool deck near the stair entrance to the pool.

      Correction: Maintain pool deck area in good repair . Repair the pool deck around the steps into the pool.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      RECIRCULATION SYSTEM CONTINUOUS OPERATION

      The pool recirculation system has a pump that is 2.0 hp. The DSPS approved plans for this pool has a 1.5 hp pump.

      Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.

      Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O

    • Serious Critical

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm. Pool tested at 15.58 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck.

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

    • Serious Critical Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions. Corrective action: new batteries were installed in the CO alarm during the inspeciton.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

Source: Barron County Department of Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.