Barron Area Commcntr Inc-whirlpool
800 MEMORIAL AVE, Barron, WI 54812 · Barron County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Barron County Department of Health & Human Services
- License / ID
- SYOG-7QRMQK
- Status
- Permitted
- Phone
- (715) 537-6666
- Official record
- Barron County Department of Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 1 |
| 2024 | 1 | 10 | 1 |
Inspections
-
Apr 10, 2026 Routine · 1 critical, 6 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition. Flow meter does not indicate the flow rate.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
SAFETY DATA SHEET
Safety data sheets were not available for a the chemicals used.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 34 after correcting the chlorine.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Some of the reagents in the kit are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Serious
Critical
Corrected on site
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A. Corrective action: adjusted whirlpool and then the chlroine was at 6.33 ppm.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
Repeat
-
Mar 5, 2024 Routine · 1 critical, 9 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
FILTER MEDIA INSPECTED ANNUALLY
Filter media is not being inspected annually or cleaned or replaced as necessary.
Correction: Inspect the filters annually and clean and replace media as needed.
Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 34.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
BIOHAZARD KIT-SCOOP AND SPATULA
The biohazard kit is missing a spatula.
Correction: For the biohazard kit, provide scoop and spatula.
Code ATCP 76.27(2)(b)1 -SCOOP AND SPATULA
-
Not serious
Non-critical
BIOHAZARD KIT-BIOHAZARD SORBENT
The biohazard kit is missing biohazard sorbent.
Correction: For the biohazard kit, provide biohazard sorbent.
Code ATCP 76.27(2)(b)8 - SORBENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Not serious
Non-critical