  1. Jul 1, 2026 Follow Up · 1 non-critical
    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Jun 5, 2026 Routine · 3 non-critical
    • Not serious Priority Foundation

      Private well testing - frequency; nitrate

      Nitrate testing of the private well was not completed once every 12 months from the date that the previous sample was completed.

      Correction: Complete nitrate testing of the private well.

      Code ATCP 72.16(2)(g)1

    • Not serious Priority Foundation

      Private well testing - frequency; bacteria

      Bacteriological testing of the private well was not completed once every 12 months from the date that the previous sample was completed.

      Correction: Complete bacteriological testing of the private well.

      Code ATCP 72.16(2)(g)1.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  3. May 8, 2025 Routine · 3 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Permit is not displayed conspicuously to the public.

      Correction: Post the permit in a conspicuous location to the public.

      Code ATCP 72.04 (7)

    • Not serious Non-critical

      SHEET SIZE AND FOLD-BACK

      Sheet foldback over the blanket was insufficient.

      Correction: Provide sheet foldback of at least 12 inches.

      Code [E] ATCP 72.11 (5)

    • Not serious Non-critical

      MATTRESS PAD PROVIDED/SUFFICIENT SIZE

      Mattress pad is not provided for the futon

      Correction: Provide a mattress pad that completely covers the mattress.

      Code [H] ATCP 72.11 (5)

  4. Jun 19, 2024 Pre-inspection Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Multi-use food contact surfaces, such as dishes are not being washed, rinsed and sanitized for different guests, or one of two alternative methods are not being used.

      Correction: All multi-use utensils must be provided sanitization through one of three methods: 1. wash, rinse, and sanitize all dishes between each guest. 2. post sanitization signage with directions for mixing an appropriate sanitizer solution and provide sanitizer. 3. provide a residential NSF dishwasher, submit a variance for the dishwasher, provide directions to guests on how to use the sanitize cycle on

      Code [A] ATCP 72.11 (3)(a)

    • Not serious Non-critical Repeat

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided in units outside of each separate sleeping area in the immediate vicinity of the sleeping rooms-basement sleeping area.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical Repeat

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided outside of each separate sleeping area in the immediate vicinity of the sleeping rooms- main floor bedroom.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical Repeat

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided outside of each separate sleeping area in the immediate vicinity of the sleeping rooms- loft bedroom.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical Repeat

      PRIVATE WELL-WATER SAMPLED, TESTED, RESULTS AVAILABLE

      A water sample for the private well serving the public has not been submitted to a certified laboratory for bacteriological analysis.

      Correction: Submit a water sample for every well that serves the public to a certified laboratory for bacteriological analysis and provide the results before the permit can be released.

      Code [F] ATCP 72.10 (3)

  5. May 28, 2024 Pre-inspection · 3 non-critical
    • Not serious Non-critical

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Multi-use food contact surfaces, such as dishes are not being washed, rinsed and sanitized for different guests, or one of two alternative methods are not being used.

      Correction: All multi-use utensils must be provided sanitization through one of three methods: 1. wash, rinse, and sanitize all dishes between each guest. 2. post sanitization signage with directions for mixing an appropriate sanitizer solution and provide sanitizer. 3. provide a residential NSF dishwasher, submit a variance for the dishwasher, provide directions to guests on how to use the sanitize cycle on

      Code [A] ATCP 72.11 (3)(a)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided in units outside of each separate sleeping area in the immediate vicinity of the sleeping rooms-basement sleeping area.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided outside of each separate sleeping area in the immediate vicinity of the sleeping rooms- main floor bedroom.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided outside of each separate sleeping area in the immediate vicinity of the sleeping rooms- loft bedroom.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical

      PRIVATE WELL-WATER SAMPLED, TESTED, RESULTS AVAILABLE

      A water sample for the private well serving the public has not been submitted to a certified laboratory for bacteriological analysis.

      Correction: Submit a water sample for every well that serves the public to a certified laboratory for bacteriological analysis and provide the results before the permit can be released.

      Code [F] ATCP 72.10 (3)