RecordWell Data

St Croix Casino & Hotel-whirlpool

631 HWY 8 & 63, Turtle Lake, WI 54889 · Barron County

23cited violations
5serious tier
3inspections

Establishment

Type
Pool / recreational water (Whirlpool)
Inspected by
Barron County Department of Health & Human Services
License / ID
SYOG-7QRMPU
Status
Permitted
Phone
(715) 986-4777
Official record
Barron County Department of Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026152
20241123
2023160

Inspections

  1. Apr 28, 2026 Routine · 2 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 37.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises: facility does not have CDC fecal accident guidelines available onsite.

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical

      AIR MOVEMENT

      Ventilation equipment not maintained and operated to provide air movement to prevent any excessive condensation. Ventilation equipment not in working condition in pool enclosure.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Telephone in pool enclosure is not working.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Phone provided maintenance during inspection and returned to working condition.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical Corrected on site

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone. Phone fixed during inspection to provide a functional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  2. Nov 18, 2024 Routine · 3 critical, 9 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. The flowmeter is maxxed out and cannot read appropriate level.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      EMERGENCY CONTACT PHONE NUMBERS

      Emergency contact phone numbers are not in the chemical storage area or readily accessible.

      Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.

      Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 44.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      OPERATING REPORTS-ANTI-ENTRAPMENT

      The operator did not record the following on the operating report: dates of anti-entrapment system testing verification.

      Correction: Record the following on the operating report, dates of anti-entrapment system testing verification.

      Code ATCP 76.32(1)(e) - ANTIENTRAP TEST

    • Not serious Non-critical

      OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT

      The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.

      Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT

    • Serious Critical

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.95 for Chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection (air gap) does not exist between potable water supply inlet and the overflow point of whirlpool.

      Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.

      Code ATCP 76.19(1) - PROTECTION

  3. Sep 7, 2023 Routine · 6 non-critical
    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is 7.9.

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 44 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 2.12 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Non-critical

      REAGENTS STORED IN ORIGINAL CONTAINERS

      -The test kit reagents are not replaced as recommended by the manufacturer- multiple bottles expired in August 2023.

      Correction: Keep reagents in original containers and replace expired product.

      Code ATCP 76.17(2)

    • Not serious Non-critical

      OUT OF SOAP

      The soap dispenser in the showers is empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Non-critical

      FIRST AID SUPPLIES MISSING

      An elastic bandage is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code [C] ATCP 76.27(1)

Source: Barron County Department of Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.