Americinn Motel
2906 PIONEER AVE S, Rice Lake, WI 54868 · Barron County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- Barron County Department of Health & Human Services
- License / ID
- PGAN-DJTRY5
- Status
- Permitted
- Phone
- (715) 234-8060
- Official record
- Barron County Department of Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 30 | 4 |
Inspections
-
Sep 16, 2025 Pre-inspection Follow Up · 2 critical, 13 non-critical, 15 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 0 % from skimmer and 100 % from main drain.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer basket for pump not available
Correction: Provide a spare strainer basket for pump.
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
TEST KIT APPROVED
Facility is utilizing Color Q Test kit for whirlpool testing.
Correction: This test kit is no longer approved for use by the department. Use a department approved test kit for daily whirlpool testing. Taylor Test kit available, but not being used for whirlpool testing.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Reagents for Taylor Test kit are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
FIRST AID KIT-EYE WASH SOLUTION
The first aid kit is missing eye wash solution.
Correction: Provide eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Not serious
Non-critical
Repeat
POOL RULES LETTER OR SYMBOL SIZE
Pool rules letters are not at least 1 inch in height.
Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.
Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BREAKPOINT CHLORINATION
The operator did not record the following on the operating report: The dates breakpoint chlorination was completed.
Correction: Record the following on the operating report, dates when breakpoint chlorination was completed.
Code ATCP 76.32(1)(c) - BREAKPOINT CHLOR
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT
The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.
Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.
Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Pool deck around entrance to whirlpool steps is damaged and not in good repair..
Correction: Maintain pool deck area in good repair. Repair pool deck around steps into the whirlpool.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
Repeat
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
Repeat
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Repeat
-
Aug 29, 2025 Pre-inspection · 2 critical, 13 non-critical
-
Not serious
Non-critical
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 0 % from skimmer and 100 % from main drain.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer basket for pump not available
Correction: Provide a spare strainer basket for pump.
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
TEST KIT APPROVED
Facility is utilizing Color Q Test kit for whirlpool testing.
Correction: This test kit is no longer approved for use by the department. Use a department approved test kit for daily whirlpool testing. Taylor Test kit available, but not being used for whirlpool testing.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Reagents for Taylor Test kit are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
FIRST AID KIT-EYE WASH SOLUTION
The first aid kit is missing eye wash solution.
Correction: Provide eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Not serious
Non-critical
POOL RULES LETTER OR SYMBOL SIZE
Pool rules letters are not at least 1 inch in height.
Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.
Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
OPERATING REPORTS-BREAKPOINT CHLORINATION
The operator did not record the following on the operating report: The dates breakpoint chlorination was completed.
Correction: Record the following on the operating report, dates when breakpoint chlorination was completed.
Code ATCP 76.32(1)(c) - BREAKPOINT CHLOR
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT
The operator did not record the following on the operating report: Date for verification of safety and rescue equipment maintained.
Correction: Record the following on the operating report: Date for verification of safety and rescue equipment maintained.
Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Pool deck around entrance to whirlpool steps is damaged and not in good repair..
Correction: Maintain pool deck area in good repair. Repair pool deck around steps into the whirlpool.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Source: Barron County Department of Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.