  1. May 29, 2026 Admin Follow Up · 2 non-critical, 2 repeat
    • Not serious Priority Foundation Repeat

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The area outside the bedroom with bunk beds in the basement does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Non-critical Repeat

      Well construction meets DNR standards

      The well cap is not in conformance with well construction standards, as enforced by the Wisconsin department of natural resources.

      Correction: Restore or repair the well to its original compliant state.

      Code ATCP 72.16(1)(b)

  2. Apr 1, 2026 Routine · 6 non-critical
    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The area outside the bedroom with bunk beds in the basement does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Handrail on stairs > 3 risers

      The bottom of the stairs in the basement is not provided with a handrail.

      Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk beds in the basement.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed [describe location].

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

    • Not serious Non-critical

      Well construction meets DNR standards

      The well cap is not in conformance with well construction standards, as enforced by the Wisconsin department of natural resources.

      Correction: Restore or repair the well to its original compliant state.

      Code ATCP 72.16(1)(b)

  3. May 10, 2024 Routine · No items found

    No violations cited.

  4. Feb 29, 2024 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SPACE HEATERS – VENTILATION REQUIREMENT

      Space heater installation does not provide a constant source of fresh air.

      Correction: Provide a constant source of fresh air through a permanent opening, prior to license being released..

      Code ATCP 72.14 (2) (a)

    • Not serious Non-critical Repeat

      FIRE EXITS – REQUIRED NUMBERS

      There are insufficient numbers of fire exits for this cabin. There is only one means of entering and exiting and the home is greater than 500 ft2. The windows in the bedroom do met exiting requirements but they are painted shut and I could not open them.

      Correction: Windows will need to be able to opened and there needs to be screens in the units during warmer months. This needs to be rectified before I can add the cabin to the license.

      Code [I] ATCP 72.14 (1)

  5. Dec 4, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      SPACE HEATERS – VENTILATION REQUIREMENT

      Space heater installation does not provide a constant source of fresh air.

      Correction: Provide a constant source of fresh air through a permanent opening, prior to license being released..

      Code ATCP 72.14 (2) (a)

    • Not serious Non-critical

      FIRE EXITS – REQUIRED NUMBERS

      There are insufficient numbers of fire exits for this cabin. There is only one means of entering and exiting and the home is greater than 500 ft2. The windows in the bedroom do met exiting requirements but they are painted shut and I could not open them.

      Correction: Windows will need to be able to opened and there needs to be screens in the units during warmer months. This needs to be rectified before I can add the cabin to the license.

      Code [I] ATCP 72.14 (1)