| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 3 | 2 |
| 2024 | 3 | 11 | 2 |
Inspections
-
Jul 30, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers, gutters, drains not maintained clean. Observed a frog in one of the skimmer buckets
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
MAX PATRON LOAD POOL
The swimming pool with a shallow end and a deep end has maximum patron load posted incorrectly. One sign states 53 and the other in the change rooms states 115
Correction: Calculate the maximum patron load to provide at least 15 square feet per patron in the shallow portion and 25 square feet per patron in the deep portion and do not allow maximum patron load to be exceeded.
Code ATCP 76.25(2)(a) - POOL
-
Not serious
Non-critical
-
Aug 13, 2025 Routine · 2 critical, 1 non-critical, 1 repeat
-
Not serious
Non-critical
HAND DRYING
Hand drying device not provided in either bathroom.
Correction: Provide individual towels in dispensers or hot air dryers at hand washing sinks.
Code ATCP 76.33 (2)(f) - HAND DRY DEVICE
-
Serious
Critical
Repeat
PH
The pH is 7.0
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
GATES AND DOORS MECHANISM 54 INCHES
A latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Not serious
Non-critical
-
Aug 15, 2024 Re-inspection · 1 critical, 1 repeat
-
Serious
Critical
Repeat
PH
The pH is above 8. Took photo.
Correction: Close the pool until the pH is back down to 7.8. Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. Send photos confirming the pH is back in range. Please call when the chemistry is back in range
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
-
Aug 10, 2024 Follow Up · No items found
No violations cited.
-
Jun 13, 2024 Routine · 1 critical, 9 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
There are no flow meters to determine turnover rate for the pool and whirlpool.].
Correction: Provide flow meters in place that is easily readable.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
CHEMICALS STORED IN ORIGINAL CONTAINER
Chemical in container just marked 50/50 and is not stored in original or properly labeled container.
Correction: Store chemicals in original or properly labeled containers.
Code ATCP 76.12 (2)(a) - CHEMICALS STORED ORIGINALCONTAINER
-
Not serious
Non-critical
CHEMICAL FEEDERS INSTALLED ACCORDING TO DIRECTIONS
Automatic system does not appear to be working.
Correction: Install the chemical feeder according to manufacturer's directions (plan review may be required).
Code ATCP 76.13 (1)(a) - INSTALLED ACCORDING TO DIRECTIONS
-
Not serious
Non-critical
FIRST AID KIT -RESUSCITATION POCKET MASK
The first aid kit is missing a resuscitation pocket mask.
Correction: Provide a resuscitation pocket mask for the first aid kit.
Code ATCP 76.27(1)(b)8.- RESUSCITATION MASK
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load has 2 different numbers posted 53 and the other sign states 110..
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. Staff could not located.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
TOILET ROOMS-GOOD REPAIR
Toilet room not maintained in good repair. Women's rest-room stall does not lock..
Correction: Maintain toilet rooms in good repair.
Code ATCP 76.33 (2)(c)2. - TOILET ROOM GOOD REPAIR
-
Not serious
Non-critical
SOAP-PROVIDED
Soap not provided in one of the showers on the mens side.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Serious
Critical
PH
The pH is [8 ].
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical