YMCA Broadview Whirlpool
380 BROADVIEW, Green Bay, WI 54301 · Brown County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Brown County Health & Human Services
- License / ID
- CKRA-9BGQ5P
- Status
- Permitted
- Phone
- (920) 436-9608
- Official record
- Brown County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 3 | 1 |
| 2023 | 1 | 5 | 1 |
Inspections
-
Jun 10, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
Corrected on site
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met.
Correction: Operator is scheduled to backwash on 6/11 which should help it meet its turnover time as it barely missed.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Corrected on site
-
Jun 2, 2025 Routine · 1 critical, 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
REPEAT: The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not locked. The door to the pool chemical room was closed and marked but not locked.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
PRIORITY: Minimum disinfectant or sanitizer level is 2.0 PPM chlorine. The minimum chlorine disinfectant level in whirlpools is 3.0 PPM. An employee arrived and turned on the jets in the whirlpool. The whirlpool was retested at 4.6 PPM. The employee explained that freshwater was added earlier and the water likely had not mixed in with the treated water fully.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
Repeat
-
Dec 21, 2023 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
No combined chlorine plan at this facility.
Correction: Create a combined chlorine plan for review at next inspection.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
Source: Brown County Health & Human Services. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.