Delta Hotels By Marriott Green Bay-whirlpool
None, WI · Brown County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Brown County Health & Human Services
- Status
- Permitted
- Official record
- Brown County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 2 | 2 | 1 |
| 2024 | 2 | 1 | 0 |
Inspections
-
Feb 5, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The turnover rate is every 35 minutes.
Correction: The whirlpool requirement for turnover time is 30 minutes.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
The railing for the spa is loose and therefore not in good repair.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
-
Mar 6, 2025 Follow Up · 1 critical, 1 repeat
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is above 10 ppm of chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
-
Jan 7, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation turnover rate has not been met. Turnover rate was 0.63hrs. A 30 minute turn over is required for a whirlpool/spa.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
-
Jul 18, 2024 Follow Up · No items found
No violations cited.
-
Jan 30, 2024 Routine · 1 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Source: Brown County Health & Human Services. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.