RecordWell Data

Polo Point Club House

None, WI · Brown County

48cited violations
14serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Brown County Health & Human Services
Status
Permitted
Official record
Brown County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
2025160
20242299
2023262

Inspections

  1. Apr 14, 2026 Routine · 3 critical, 4 non-critical, 1 repeat
    • Not serious Non-critical

      INTERLOCK LOG-MADE AVAILABLE

      Log of interlock testing not made available to the department or its agent upon request.

      Correction: Make interlock test log available to the department or its agent upon request.

      Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Almost all of the reagents in used have expired. R-0008 expired 4/23, R-0004 expired 7/25 and 12/25, R.0871 expired 9/25, R- 0872 expired 7/25 and R-0003 expired 04/24 and 03/23.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      RESCUE EQUIPMENT ACCESSIBLE

      TThe rescue equipment is not in a conspicuous place and readily accessible. The ring buoy and shepherd's hook are placed on the floor and behind a couple of beach chairs and table and was not easily found during the inspection. Operator will find an area to hang the buoy where it can be easily accessible and visible.

      Correction: Maintain rescue equipment in a conspicuous and accessible location.

      Code ATCP 76.26(1)(a)2. - RESCUE EQPT ACCESSIBLE

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      CRITICAL HAZARD - The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical

      INTERLOCK LOG-INFORMATION

      CRITICAL HAZARD - The monthly testing log is missing or incomplete. PIC did not know what inspector was talking about.

      Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.

      Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      CRITICAL HAZARD - There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. May 20, 2025 Routine · 6 non-critical, 1 repeat
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is 100% and 50%. During the inspection the drain valves were adjusted to 20% main drain and 80% skimmer.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. R009 expires 3/2023,

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY

      The cordless phone with a charging base does not have connection to permanent power supply.The cordless phone is a temporary solution until the coreded phone can be replaced.

      Correction: Provide a connection to permanent power supply.

      Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      POOL DECK-INDOOR-DISINFECTED

      Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions.

      Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.

      Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED

  3. Oct 8, 2024 Routine · 8 critical, 20 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The [ ] is not being maintained in operating condition. [Describe].

      Correction: Adjust or repair the [ ].

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      EMERGENCY CONTACT PHONE NUMBERS

      Emergency contact phone numbers are not in the chemical storage area or readily accessible.

      Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.

      Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Swimming pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. [Describe].

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      POOL WATER TESTED PEAK PATRON LOAD, PH AND SANITIZER

      Pool water not tested for pH and disinfectant at least one other time during the day’s peak patron load.

      Correction: Test pool water for pH and disinfectant at least one time during the day’s peak patron load.

      Code ATCP 76.18(1)(a)2 - WATER TESTED, SANITIZER, PH, PEAK LOAD P

    • Not serious Non-critical

      ELECTRONIC MONITORING FREQUENCY OF TESTING

      The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.

      Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.

      Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ

    • Not serious Non-critical

      ELECTRONIC MONITORING MAINTENANCE

      The electronic monitoring device has not been periodically monitored for proper functioning [Describe].

      Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate.

      Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED

    • Not serious Non-critical

      OPERATOR REQUIRED

      The pool is not under the supervision of an operator.

      Correction: Provide an operator for the pool.

      Code ATCP 76.20(1)(a) - OPERATOR REQUIRED

    • Not serious Non-critical

      RESPONSIBLE SUPERVISOR INTERLOCK TESTING

      Responsible supervisor is not ensuring that monthly interlock testing is done. [Describe].

      Correction: Have the responsible supervisor ensure that monthly interlock tests are done.

      Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone. [Describe].

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL EQUIPMENT- PROPERLY LOCATED

      The pool equipment is not properly located. [Describe].

      Correction: Locate the pool equipment [Describe].

      Code ATCP 76.33(1)(e)1. - LOCATION OF POOL EQPT

    • Not serious Non-critical

      POOL EQUIPMENT-REPAIRED AS NECESSARY

      The pool equipment is not repaired as necessary. [Describe].

      Correction: The pool equipment is not repaired as necessary [Describe].

      Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED

    • Not serious Non-critical

      DRINKING FOUNTAIN MAINTAINED

      The drinking fountain is not in clean and sanitary condition. [Describe].

      Correction: Maintain the drinking fountain in clean and sanitary condition.

      Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN

    • Serious Critical

      CHEMICAL STORAGE ACCESS RESTRICTED

      Chemical storage area access not restricted to authorized personnel.

      Correction: Restrict access to chemical storage area to only authorized personnel.

      Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED

    • Serious Critical

      SMOKING-HANDLING

      A person handling chemicals or in immediate vicinity was smoking.

      Correction: Do not allow smoking near chemical handling activities.

      Code ATCP 76.12 (4)(a) - NO SMOKING WHERE CHEMICALS HANDLED

    • Serious Critical

      RESPONSIBLE SUPERVISOR POOL RULES

      Responsible supervisor is not ensuring that pool rules are enforced. [Describe].

      Correction: Have the responsible supervisor ensure that pool rules are enforced as needed.

      Code ATCP 76.21 (1)(c)3. - POOL RULES ENFORCED

    • Serious Critical

      RESPONSIBLE SUPERVISOR SANITATION AND TESTING

      Responsible supervisor is not ensuring that sanitation and testing is performed. [Describe].

      Correction: Have the responsible supervisor ensure that sanitation and testing duties are performed.

      Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING

    • Serious Critical

      SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH

      The shepherd's crook is not long enough to effect a rescue in the deepest part of pool. [Describe].

      Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool.

      Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO

    • Serious Critical

      SHEPHERD'S CROOK PIECES SECURELY CONNECTED

      The shepherd's crook is not a continuous pole and the pieces are not securely held together.

      Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.

      Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN

    • Serious Critical

      GATES AND DOORS LOCKED WHEN POOL NOT OPEN

      Gate or door not locked when the pool was not open to the public.

      Correction: Lock the gate or door when the pool is not open to the public.

      Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED

    • Serious Critical

      GATES AND DOORS-LATCHING

      The gate or door does not latch. [Describe].

      Correction: Provide a latching door.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

  4. Jan 16, 2024 Follow Up · 1 critical, 1 repeat
    • Serious Critical Repeat

      CLOSING CRITERIA-HAZARDOUS SUBSTANCE OR OBJECT

      The Responsible Supervisor or operator has not closed the pool a hazard or condition creating an immediate danger to health or safety. Pool sample tested positive for E.coli..

      Correction: Close the pool in the event of presence of a hazardous substance or object in the pool or the existence of any condition creating an immediate danger to health or safety, including fecal accident events.

      Code ATCP 76.30 (1)(a)-HAZARDOUS SUBSTANCE OR OBJECT

  5. Oct 12, 2023 Follow Up · 1 critical, 4 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Monthly pool logs do not indicate that pool is tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  6. Oct 11, 2023 Routine · 1 critical
    • Serious Critical

      CLOSING CRITERIA-NON-OPERATIONAL RECIRD PUMP

      The Responsible Supervisor or operator has not closed the pool when there is a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder. Clorine disinfectant is measured at 0.6 PPM..

      Correction: Close the pool in the event of a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder.

      Code ATCP 76.30 (1)(d) - NON-OPERATIONAL RECIRC PUMP

Source: Brown County Health & Human Services. History last read Oct 4, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.