Americinn Lodge & Suites, Gb East
2628 MANITOWOC RD, Green Bay, WI 54311 · Brown County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Brown County Health & Human Services
- License / ID
- RQUO-B6PRX4
- Status
- Permitted
- Phone
- (920) 964-0177
- Official record
- Brown County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 12 | 3 |
| 2024 | 2 | 8 | 1 |
Inspections
-
Feb 4, 2026 Follow Up · No items found
No violations cited.
-
Jan 8, 2026 Follow Up · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
REPEAT: The flowmeter is not being maintained in operating condition. The digital flowmeter does not display the flowrate. 1/8/26: A new flowmeter for the spa is on order and will be installed by KS Pool Tech.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Not serious
Non-critical
Repeat
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The shower, toilet and dressing facilities are not maintained in good repair. Water in the sinks in boths the mens and womens rooms does not heat up above ambient temperatures. Lights are burned out or flickering in the womens room.
Correction: Maintain the shower, toilet and dressing facilities in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
Jan 6, 2026 Routine · 3 critical, 5 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
REPEAT: The flowmeter is not being maintained in operating condition. The digital flowmeter does not display the flowrate.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirlpool and pool water is tested daily but not recorded.
Correction: Test pool water at least daily for the combined chlorine level and record results in the chemical testing log.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Not serious
Non-critical
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The shower, toilet and dressing facilities are not maintained in good repair. Water in the sinks in boths the mens and womens rooms does not heat up above ambient temperatures. Lights are burned out or flickering in the womens room.
Correction: Maintain the shower, toilet and dressing facilities in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Serious
Critical
PH
CRITICAL: The pH is less than 7.0. Exact pH was not able to be determined due to the color comparator only measuring down to 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
CLOSING CRITERIA-HAZARDOUS SUBSTANCE OR OBJECT
CRITICAL: The combined chlorine in the whirlpool was measured at 5.0 PPM.
Correction: Close the pool in the event of presence of a hazardous substance or object in the pool or the existence of any condition creating an immediate danger to health or safety, including fecal accident events. Drain and refill the pool.
Code ATCP 76.30 (1)(a)-HAZARDOUS SUBSTANCE OR OBJECT
-
Serious
Critical
HAZARDOUS CONDITION
CRITICAL: There is a hazardous condition at the whirlpool. The main drain covers in the whirlpool are missing two screws.
Correction: Correct the hazardous condition. Replace screws with like-for-like screws per manufacturer's instructions.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Dec 19, 2024 Routine · 1 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. A skimmer basket is broken and is in use.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 330.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. The pool is not tested when the pool operator is not working. Testing must be done on all days when the pool is open.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Serious
Critical
HAZARDOUS CONDITION
CRITICAL: There is a hazardous condition at the pool. A railing to the whirlpool is loose.
Correction: Correct the hazardous condition. Tighten and seucre all railings.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
-
Jan 16, 2024 Routine · 3 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The spa effluent pressure gauge and flow meter are not being maintained in operating condition and are not functioning.
Correction: Adjust or repair the gauge and flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
No combined chlorine plan is present at the facility. Combined chlorine was measured at 3.2 ppm which is above the maximum allowable level of 0.8 ppm. Water source was tested at 0.0 ppm combined chlorine.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Reduce combined chlorine to 0.8 ppm or less.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Source: Brown County Health & Human Services. History last read Oct 4, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.