RecordWell Data

Green Bay YMCA Ferguson Family Y-whirl Pool

235 N JEFFERSON ST, Green Bay, WI 54301 · Brown County

11cited violations
1serious tier
4inspections

Establishment

Type
Pool / recreational water (Whirlpool)
Inspected by
Brown County Health & Human Services
License / ID
HSAT-7QWEH5
Status
Permitted
Phone
(920) 436-9622
Official record
Brown County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
2025151
2024130
2023110

Inspections

  1. Sep 10, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      CURRENT LICENSE

      A pool, opened to the public, is located on the premises does not have a current license. The licenses on premise expired on 06/30/2026.

      Correction: The pool must be closed to the public immediately and may not operate until a valid license is issued from the department.

      Code ATCP 76.05(1)(a) - LICENSE CURRENT

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition.

      Correction: Adjust or repair the [ ].

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  2. Jul 15, 2025 Routine · 1 critical, 4 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40 PPM.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. pH reagent, R-0003 and R-0011 expired on 11/24, 1/25 and 3/25, respectively.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      Facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment (exhaust ventilation cover) above the whirlpool is not properly maintained. Equipment was noted severely corroded on the sides / edges.

      Correction: Maintain the pool equipment. Replace cover.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical Corrected on site

      RESPONSIBLE SUPERVISOR POOL RULES

      CRITICAL HAZARD- Responsible supervisor is not ensuring that pool rules are enforced. A 10 year old young man was noticed in the whirlpool without any adult supervision. Education was provided and child got out of the pool after a few minutes.

      Correction: Have the responsible supervisor ensure that pool rules are enforced as needed.

      Code ATCP 76.21 (1)(c)3. - POOL RULES ENFORCED

  3. Sep 4, 2024 Routine · 3 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

  4. Aug 24, 2023 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      REPEAT: The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

Source: Brown County Health & Human Services. History last read Oct 4, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.