RecordWell Data

Quality Inn & Suites (whirlpool)

321 S WASHINGTON ST, Green Bay, WI 54301 · Brown County

11cited violations
2serious tier
5inspections

Establishment

Type
Pool / recreational water (Whirlpool)
Inspected by
Brown County Health & Human Services
License / ID
RQUO-CG9N23
Status
Permitted
Phone
(920) 328-1074
Official record
Brown County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025110
2024371
2023131

Inspections

  1. Dec 11, 2025 Routine · 1 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. At 45 gallons per minute in a 1,900 gallon pool the turnover rate is 0.7 hours, longer than the required 0.5 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 0.5 hours.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

  2. Oct 31, 2024 Routine · 2 non-critical, 1 repeat
    • Not serious Non-critical

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is roughly equal.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical Repeat

      ALKALINITY

      REPEAT: The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

  3. Jan 25, 2024 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS MAINTAINED CLEAN

      Skimmers not maintained clean. Spa skimmer observed with hair and debris build-up.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

  4. Jan 23, 2024 Follow Up · 1 critical, 2 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SKIMMERS MAINTAINED CLEAN

      Skimmers not maintained clean. Spa skimmer observed with hair and debris build-up.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical Repeat

      HAZARDOUS CONDITION

      CRITICAL: There is a hazardous condition at the pool. Multiple tiles are missing in the spa and jet covers are missing.

      Correction: Correct the hazardous condition and replace all broken or missing equipment.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  5. Dec 8, 2023 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmers not maintained clean. Spa skimmer observed with hair and debris build-up.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      HAZARDOUS CONDITION

      CRITICAL: There is a hazardous condition at the pool. Multiple tiles are missing in the spa and jet covers are missing.

      Correction: Correct the hazardous condition and replace all broken or missing equipment.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

Source: Brown County Health & Human Services. History last read Oct 4, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.