Comfort Inn & Suites
2850 S ONEIDA ST, Green Bay, WI 54304 · Brown County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Brown County Health & Human Services
- License / ID
- MCUY-D8LLR7
- Status
- Permitted
- Phone
- (920) 497-1010
- Official record
- Brown County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 15 | 4 |
| 2024 | 2 | 2 | 0 |
Inspections
-
Jan 20, 2026 Follow Up · 5 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. R-0007 expired 7/25.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirlpool and pool water is not tested at least twice a week for the combined chlorine level. The combined chlorine level was 1.0 ppm.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down when required and daily maintenance of water quality pursuant.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
Repeat
FIRST AID KIT-EYE WASH SOLUTION
The eye wash solution and antiseptic spray in first aid kit expired 5/2025 and 9/24, respectively .
Correction: Provide eye wash solution and antiseptic for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. Operator has no idea where those documents are.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
-
Jan 16, 2026 Routine · 4 critical, 6 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 575mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. R-0007 expired 7/25.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirlpool and pool water is not tested at least twice a week for the combined chlorine level. The combined chlorine level was 1.0 ppm.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down when required and daily maintenance of water quality pursuant.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
FIRST AID KIT-EYE WASH SOLUTION
The eye wash solution and antiseptic spray in first aid kit expired 5/2025 and 9/24, respectively .
Correction: Provide eye wash solution and antiseptic for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. Operator has no idea where those documents are.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
CRITICAL HAZARD - Minimum disinfectant or sanitizer level is 1.2 PPM for chlorine. Inspector closed down pool during inspection.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
CRITICAL HAZARD - The pH is 8.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-FAILURE TO MEET 76.16
CRITICAL HAZARD - The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. The pool disinfectant levels were below the required limits for weeks as well as on the day of the inspection but operator failed to close the pool for maintenance. Pool was closed during inspection.
Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16.
Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
CRITICAL HAZARD - The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. The pool disinfectant levels was below the required limits for weeks as well as on the day of the inspection but operator failed to close the pool for maintenance. The pH level of the whirlpool was high. Pool was closed during inspection.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Not serious
Non-critical
-
Sep 16, 2024 Follow Up · No items found
No violations cited.
-
Sep 5, 2024 Pre-inspection · 2 non-critical
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY INSTALLLED
The light on the side of the pool basin is loose.
Correction: Reattached the light so it is properly secured.
Code ATCP 76.33(1)(e)2. - INSTALLATION OF POOL EQPT.
-
Not serious
Non-critical
Source: Brown County Health & Human Services. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.