Pheasant Run Apartments-swimming Pool
2970 MOSSY OAK CIR, Green Bay, WI 54311 · Brown County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- Brown County Health & Human Services
- License / ID
- RQUO-APMMC7
- Status
- Permitted
- Phone
- (920) 469-7922
- Official record
- Brown County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 7 | 1 |
| 2025 | 1 | 8 | 2 |
| 2024 | 1 | 9 | 0 |
| 2023 | 1 | 10 | 2 |
Inspections
-
Sep 14, 2026 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. There is significant pitting in the bottom of the pool basin.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
WALLS, CEILINGS, FLOORS
The walls, ceilings and floors in a pool area have not been maintained in clean and sanitary condition. There is heavy dust build up, water damage and missing tiled on the ceiling.
Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The handles of the ladder in the pool are not secured properly to the pool deck and move when handled.
Correction: Maintain the pool equipment [Describe].
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
-
Sep 10, 2026 Routine · 1 critical, 3 non-critical
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. There is significant pitting in the bottom of the pool basin.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
WALLS, CEILINGS, FLOORS
The walls, ceilings and floors in a pool area have not been maintained in clean and sanitary condition. There is heavy dust build up, water damage and missing tiled on the ceiling.
Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The handles of the ladder in the pool are not secured properly to the pool deck and move when handled.
Correction: Maintain the pool equipment [Describe].
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
PH
CRITICAL: The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Jul 15, 2025 Routine · 2 critical, 6 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmer is not maintained clean. The skimmer is noted with hair, toys, plastic and debris.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. There was no flowmeter installed.
Correction: Install a flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is unknown as it is not programmed into the monitor and water has not been tested manually as pool operator does not have knowledge of how to manually test the pool for ORP.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
WATER LEVEL-SKIMMERS MAINTAINED
Water level in a skimmer pool is not allowing for effective skimming. The water level is so low below the skimmers due to a problem with the pump and equipment that is currently leaking. Operator keeps filling the pool frequently to maintain the water level of the pool.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained for review during inspection.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
AIR MOVEMENT
The dehumidifier in the equipment room is not maintained and operated to provide air movement to prevent any excessive condensation. The equipment was broken down during inspection. The facility has ordered equipment and awaiting the arrival and installation of the equipment.
Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.
Code ATCP 76.33(4)(b) - AIR MOVEMENT
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
CRITICAL HAZARD: - There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room. Operator installed a new carbon monoxide detector during inspection and tested it.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
HAZARDOUS CONDITION
CRITICAL HAZARD - There is a hazardous condition at the pool. The pool ladder on the West facing side of the pool is not safely secured. The right handrail pulled right out of the pool deck.
Correction: Correct the hazardous condition. Repair pool handle by safely securing it back onto the pool deck.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
-
Aug 28, 2024 Routine · 9 non-critical
-
Not serious
Non-critical
DIATOMACEOUS EARTH FILTERS BACKWASHED AS RECOMMENDED BY MANUFACTURER
The filter is not being backwashed as recommended by manufacturer.
Correction: Backwash the diatomaceous earth filter as recommended by manufacturer.
Code ATCP 76.11(6)(c) 1. - DIATOMACEOUS EARTH FILTER BACKWASH
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Corrected on site
DRINKING FOUNTAIN MAINTAINED
The drinking fountain is not in clean and sanitary condition. There was vomit residue in the drinking fountain at the time of the inspection. Operator cleaned the water fountain at the time of the inspection.
Correction: Maintain the drinking fountain in clean and sanitary condition.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Not serious
Non-critical
-
Jul 31, 2023 Routine · 2 critical, 7 non-critical, 2 repeat
-
Not serious
Non-critical
PERMIT NOT POSTED
The current permit is not posted in a place visible to the public.
Correction: Post the permit in public view.
Code ATCP 76.05(7)
-
Not serious
Non-critical
EQUIPMENT NOT MAINTAINED
Some of the pool ceiling tiles are not being maintained and repaired as necessary. Ceiling tiles are noted out of place. The one above the pool is entirely removed from place and a couple more with water damage and gaps on the sides.
Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).
Code ATCP 76.33(1)(e)
-
Not serious
Non-critical
IN NEED OF REPAIR
One of the drains on the west end of the pool deck is in need of repair. The drain cover is noted cover is noted broken leaking pieces of plastic debris and a hole in the floor.
Correction: Repair and maintain in accordance with recognized safe practices.
Code ATCP 76.37(1)(a)
-
Not serious
Non-critical
IN NEED OF REPAIR
There are multiple areas on the pool deck noted with uneven surfaces and chipped cemented floors that is a trip hazard to patrons. These areas are in need of repair.
Correction: Repair and maintain in accordance with recognized safe practices.
Code ATCP 76.37(1)(a)
-
Not serious
Non-critical
SPINE BOARD NOT AVAILABLE
The spine board in the facility has no straps.
Correction: Provide a spine board in compliance with ATCP 76.26(1)(d) immediately.
Code [A] ATCP 76.26(1)(d)
-
Not serious
Non-critical
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1).
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Repeat
RECORD RETENTION
The monthly operating reports and current daily inspections and operational tests for 2023 to date as specified in s. ATCP 76.37.required under sub. (1). is not available for review.
Correction: Keep records in accordance with ATCP 76.32(3).
Code [A] ATCP 76.32(3)
-
Not serious
Non-critical
Repeat
CRACKS OR PITTING IN THE POOL BASIN
The pool basin is extensively pitted or damaged.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Serious
Critical
TELEPHONE NOT WORKING
CRITICAL HAZARD - The emergency telephone does not work. There is no dial tone. The phone is dead.
Correction: Provide a functional emergency telephone immediately.
Code [A] ATCP 76.26(2)
-
Serious
Critical
HEAD IMMOBILIZER NOT IN PLACE
CRITICAL HAZARD - The head immobilizer is not in place on the spine board.
Correction: Strap the head immobilizer to the spine board so it is ready for use in an emergency response.
Code [B] ATCP 76.26(1)(d)
-
Not serious
Non-critical
Source: Brown County Health & Human Services. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.