RecordWell Data

Buckhorn Station Apartments Pool

4560 S NICHOLSON AVE, Cudahy, WI 53110 · Milwaukee County

12cited violations
3serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis)
License / ID
CMAL-D7AK4U
Status
Permitted
Phone
(414) 483-3750
Official record
Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis) inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026232
2024391

Inspections

  1. Jun 9, 2026 Follow Up · No items found

    No violations cited.

  2. Jun 8, 2026 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not in operating condition.

      Correction: Repair flowmeter. Flowmeter should read 60 gpm or above so that pool is recirculating at least every 6 hours.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.6ppm for chlorine. This is too low for operating pool.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Chlorine level should be a minimum 1ppm and a maximum 10ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH appears to be 7.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. Try to aim for 7.4-7.6 for pH.

      Code ATCP 76.14(5)(c) - PH

  3. Jul 17, 2024 Follow Up · No items found

    No violations cited.

  4. Jul 11, 2024 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public once application and fees have been submitted to the department.

      Code ATCP 76.05(7) - LICENSE POSTED

  5. Jun 27, 2024 Pre-inspection · 1 critical, 7 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public once application and fees have been submitted to the department.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      PUMP, CONTINUOUS OPERATION

      Unable to calculate turnover rate. Flowmeter is not in working order

      Correction: Operate the pump continuously to achieve the designed recirculation rate. Repair flow meter so that the turnover rate can be calculated and monitored.

      Code ATCP 76.11(4)(b) - PUMP CONTINUOUS OPERATION

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL BASIN MAINTAINED CLEAN AND SANITARY

      Pool basin not maintained in a clean and sanitary condition

      Correction: Maintained the pool basin in a clean and sanitary condition.

      Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      The drinking fountain is not in good repair.

      Correction: Repair the drinking fountain.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

Source: Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis). History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.