Southtowne Reserve Apts I Pool
333 SOUTHTOWNE DR, South Milwaukee, WI 53172 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis)
- License / ID
- CMAL-CU3JTC
- Status
- Permitted
- Phone
- (920) 413-1471
- Official record
- Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis) inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 2 | 1 |
| 2025 | 4 | 15 | 2 |
| 2024 | 4 | 10 | 1 |
| 2023 | 5 | 16 | 0 |
Inspections
-
Jun 9, 2026 Follow Up · No items found
No violations cited.
-
May 13, 2026 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
An emergency phone number not attached or posted near telephone.
Correction: Provide an emergency number near telephone.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
The drinking fountain is not working.
Correction: Provide a working drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
-
Jul 1, 2025 Follow Up · No items found
No violations cited.
-
Jun 26, 2025 Follow Up · 1 critical, 6 non-critical, 7 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
Unable to determine pool turnover rate.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter so that it reads 140gpm or above.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Repeat
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
Repeat
TOILET ROOMS-CLEAN
Bathrooms are in need of cleaning.
Correction: Keep the toilet rooms clean.
Code ATCP 76.33 (2)(c)1. TOILET ROOM CLEAN
-
Serious
Critical
Repeat
PH
The pH appears to be 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Repeat
-
Jun 4, 2025 Follow Up · No items found
No violations cited.
-
Jun 3, 2025 Routine · 1 critical, 7 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
Unable to determine pool turnover rate.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter so that it reads 140gpm or above.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
There is no combined chlorine plan for facility.
Correction: Create combined chlorine plan and forward to health department. Keep plan on file.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
TOILET ROOMS-CLEAN
Bathrooms are in need of cleaning.
Correction: Keep the toilet rooms clean.
Code ATCP 76.33 (2)(c)1. TOILET ROOM CLEAN
-
Serious
Critical
PH
The pH appears to be 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Repeat
-
Aug 27, 2024 Re-inspection 2 · 1 non-critical
-
Not serious
Non-critical
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
-
Jun 20, 2024 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The flow meter is reading about 65 gpm. The recirculation (turnover) rate is 13 hours which means that the water is not circulating fast enough.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours. Flow meter be reading around 140 gpm.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
-
May 31, 2024 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The flow meter is reading about 70 gpm. The recirculation (turnover) rate is 12 hours which means that the water is not circulating fast enough.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours. Flow meter be reading around 140 gpm.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
One filter pressure gauge is reading 0psi and is not being maintained in operating condition.
Correction: Adjust or repair the filter pressure gauge that is reading 0 psi
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. Main drain and eqaulizer covers expired April 2024.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
May 23, 2024 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmer baskets are full of leaves and debris.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The flow meter is reading about 70 gpm. The recirculation (turnover) rate is 12 hours which means that the water is not circulating fast enough.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours. Flow meter should be reading around 140 gpm.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
One filter pressure gauge is reading 0psi and is not being maintained in operating condition.
Correction: Adjust or repair the filter pressure gauge that is reading 0 psi
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. Main drain and eqaulizer covers expired April 2024.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. Someone must be in the office in case an emergency occurrs if pool wants to be open without properly funcitoning emergency phone. Put a note up so swimmers know where to go to utilize emergency phone.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Aug 28, 2023 Follow Up · 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION RATE NOT MET - POOLS
The flowmeter is reading 60 gpm meaning the pool has a turnover rate of 14 hrs. The max for a swimming pool is supposed to be 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
The pool is missing two weir doors.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
-
Aug 24, 2023 Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION RATE NOT MET - POOLS
The flowmeter is reading 60 gpm meaning the pool has a turnover rate of 14 hrs. The max for a swimming pool is supposed to be 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
Repeat
SKIMMER BASKET OR WEIR MISSING
The pool is missing two weir doors.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
-
Aug 3, 2023 Follow Up · 2 non-critical, 1 repeat
-
Not serious
Non-critical
RECIRCULATION RATE NOT MET - POOLS
The flowmeter is reading 60 gpm meaning the pool has a turnover rate of 14 hrs. The max for a swimming pool is supposed to be 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
Repeat
SKIMMER BASKET OR WEIR MISSING
The pool is missing two weir doors.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
-
Jul 19, 2023 Follow Up · 5 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
PERMIT DOES NOT REFLECT CURRENT OWNERSHIP
The permit does not reflect the current ownership.
Correction: The operator must acquire a valid permit. Submit application and fees for pool license.
Code ATCP 76.05(1)(b)(2)
-
Not serious
Non-critical
Repeat
RECIRCULATION RATE NOT MET - POOLS
Unable to calculate turnover rate for pool.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flowmeter is not in working condition
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
SKIMMER BASKET OR WEIR MISSING
The pool is missing two weir doors.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
EMERGENCY CONTACT PHONE NUMBERS NOT POSTED
The emergency numbers or facility address are not posted near the designated emergency phone.
Correction: Post the emergency numbers and facility address near the designated emergency phone.
Code [C] ATCP 76.26(2)
-
Not serious
Non-critical
Repeat
-
Jun 21, 2023 Pre-inspection · 5 non-critical
-
Not serious
Non-critical
PERMIT DOES NOT REFLECT CURRENT OWNERSHIP
The permit does not reflect the current ownership.
Correction: The operator must acquire a valid permit. Submit application and fees for pool license.
Code ATCP 76.05(1)(b)(2)
-
Not serious
Non-critical
RECIRCULATION RATE NOT MET - POOLS
Unable to calculate turnover rate for pool.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flowmeter is not in working condition
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
The pool is missing two weir doors.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS NOT POSTED
The emergency numbers or facility address are not posted near the designated emergency phone.
Correction: Post the emergency numbers and facility address near the designated emergency phone.
Code [C] ATCP 76.26(2)
-
Not serious
Non-critical
Source: Environmental Health Consortium (Cudahy, South Milwaukee, St. Francis). History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.