Village Club INC - Outdoor Wading Pool
6263 SHERWOOD RD, Greendale, WI 53129 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Greendale Health Department
- License / ID
- HSAT-7QXRW2
- Status
- Permitted
- Phone
- (414) 761-9871
- Official record
- Greendale Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 16 | 3 |
| 2025 | 2 | 19 | 3 |
| 2024 | 1 | 3 | 2 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Aug 19, 2026 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
Repeat
POOL RULES SIGNAGE-NO ANIMALS
Pool rules missing rule: Do not bring animals into the pool area.
Correction: Include pool rule on sign: Do not bring animals into the pool area.
Code ATCP 76.29(1)(b)1.e. - NO ANIMALS
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
-
Aug 12, 2026 Routine · 3 critical, 10 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer door not attached.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
Corrected on site
SKIMMER COVERS SECURELY SEATED ON DECK
Skimmer covers not securely seated on deck. Screwed securely to the deck.
Correction: Ensure that skimmer covers are securely seated on deck.
Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK
-
Not serious
Non-critical
Repeat
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY
Telephone does not have connection to permanent power supply.
Correction: Provide a connection to permanent power supply.
Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
The facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
POOL RULES SIGNAGE-NO ANIMALS
Pool rules missing rule: Do not bring animals into the pool area.
Correction: Include pool rule on sign: Do not bring animals into the pool area.
Code ATCP 76.29(1)(b)1.e. - NO ANIMALS
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Corrected on site
GATES AND DOORS-LIFEGUARD STAFFING PLAN
In the lifeguarded pool area: Gates and doors are not self-closing and latching, and the gates and doors to the pool are not staffed with an attendent and at least one lifeguard present. Observed the gate to the tennis court are not self closing and latching. Public can enter the pool from tennis area. PIC then had a lifeguard staff enterance. Discussed with PIC. PIC will have a lifeguard present when tennis classes are occuring when guest can enter the tennis court from the outside of the tennis courts will be locked. All guest will then enter the area from main enterance where it is staffed at all times.
Correction: Provide at least one attendant or lifeguard at the gate or door and at least one lifeguard, or close the pool and lock gate or door until an attendant and lifeguard can be provided.
Code ATCP 76.34(4)(b)2. - GATE/DOOR STAFFING IN PLAN
-
Serious
Critical
Corrected on site
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
HOSING - BACKFLOW PREVENTION DEVICE
There is no backflow prevention device attached to hose spigot in the pump room.
Correction: Attach a backflow prevention device onto hose spigot.
Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
Observed the operator does have the pump curve but does not have which curve is for the pump and drain cover specifications are missing such as lifespan, gpm, and model number. Informed PIC and the VGBA cover log will be emailed.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Jul 18, 2025 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
-
Jul 9, 2025 Routine · 3 critical, 14 non-critical
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
SKIMMER COVERS SECURELY SEATED ON DECK
Skimmer covers not securely seated on deck. The covers were placed into the skimmer opening but were not screwed down and were loosely seated on the deck.
Correction: Ensure that skimmer covers are securely seated on deck.
Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is no conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
RESPONSIBLE SUPERVISOR INTERLOCK TESTING
Responsible supervisor is not ensuring that monthly interlock testing is done. Monthly interlock tests are not being done or recorded.
Correction: Have the responsible supervisor ensure that monthly interlock tests are done.
Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
No lifeguard and attendant staffing plan is available.
Correction: Prepare and maintain a lifeguard staffing plan.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING, SUPERVISION ENCLOSURE MORE THAN ONE POOL
Where there are lifeguarded and non-lifeguarded pools in an enclosure, the lifeguard and attendant staffing plan does not state the method for periodic supervision.
Correction: State the method for periodic supervision where there are lifeguarded and non-lifeguarded pools in an enclosure, in the lifeguard and attendant staffing plan.
Code ATCP 76.22(1)(b)9. UNSTAFFED POOLS IN ENCLOSURE
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not able to describe how monthly testing is performed.
Correction: Ensure that operator can describe how monthly testing is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained. Free/Total Chlorine test results are being recorded in the wrong location on daily test logs.
Correction: Have the responsible supervisor ensure that records are maintained.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Not serious
Non-critical
-
Aug 13, 2024 Re-inspection · 2 critical, 1 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
CHEMICAL FEEDERS USED-CAPABLE OF PROVIDING REQUIRED RESIDUAL
Chlorine feeder is not capable of providing required chemical residual: chlorine concentration exceeded 10 ppm.
Correction: Install a chemical feeder that is capable of providing the required chemical residual (plan review may be required). Repair ir replace chemical feeder to ensure appropriate levels of chlorine disinfectant are provided.
Code ATCP 76.13(1)(b)3. - CAPABLE OF PROVIDING REQUIRED RESIDUAL
-
Serious
Critical
Repeat
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
Repeat
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. Pool was open despite the fluctuating and unstable chlorine levels above 10 ppm.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Not serious
Non-critical
Repeat
-
Jun 15, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is 7.0..
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
The skimmer weir is missing.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Source: Greendale Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.