RecordWell Data

Village Club INC - Intermediate Pool

6263 SHERWOOD RD, Greendale, WI 53129 · Milwaukee County

42cited violations
7serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Greendale Health Department
License / ID
HSAT-7QXCJQ
Status
Permitted
Phone
(414) 761-9871
Official record
Greendale Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262203
20252183
2024121
2023120

Inspections

  1. Aug 19, 2026 Re-inspection · 4 non-critical, 3 repeat
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the wading pool recirculation (turnover) rate has not been met. The calcuated turnover rate is 2 hours. Provided education and PIC will backwash to see if the can get the backwash to get the turnoverate to

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate to 1 hour.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-SHOWER

      Observed pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities. Informed PIC

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-NO ANIMALS

      Observed pool rules missing rule: Do not bring animals into the pool area. Informed PIC.

      Correction: Include pool rule on sign: Do not bring animals into the pool area.

      Code ATCP 76.29(1)(b)1.e. - NO ANIMALS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Observed Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided. Informed PIC

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  2. Aug 12, 2026 Routine · 3 critical, 13 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      LICENSE NOT POSTED

      Observed the license is not posted for public view. Informed PIC and PIC is looking for the license.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Observed all the skimmers are missing the weir doors. Provided edcuation to Person In Charge about weir doors or floating weirs.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat Corrected on site

      SKIMMER COVERS SECURELY SEATED ON DECK

      Observed the skimmer covers not securely seated on deck. Observed the screws are missing. Informed PIC and PIC place screws into the lids.

      Correction: Ensure that skimmer covers are securely seated on deck.

      Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the wading pool recirculation (turnover) rate has not been met. The calcuated turnover rate is 2 hours. Provided education and PIC will backwash to see if the can get the backwash to get the turnoverate to

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate to 1 hour.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      Observed the backwash procedure is no conspicuously posted on an easily read chart in the filter area. Provided education and PIC stated they will get the backwash procedures posted.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 615 mV and water has not been tested manually. PIC did not know how to manually, PIC started increased the monitor.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY

      Observed the phone does not have connection to permanent power supply. Observed the phone can be removed from the receiver. Instructed PIC they need a phone that cannot be removed from the power supply. Will email fact sheet about approved emergency phones to PIC

      Correction: Provide a connection to permanent power supply.

      Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER

    • Not serious Non-critical Corrected on site

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      Observed list of emergency numbers is post but facility address not attached or posted near telephone. Provided education to PIC and PIC will post the address.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      POOL RULES SIGNAGE-SHOWER

      Observed pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities. Informed PIC

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

    • Not serious Non-critical

      POOL RULES SIGNAGE-NO ANIMALS

      Observed pool rules missing rule: Do not bring animals into the pool area. Informed PIC.

      Correction: Include pool rule on sign: Do not bring animals into the pool area.

      Code ATCP 76.29(1)(b)1.e. - NO ANIMALS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Observed Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided. Informed PIC

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      Observed the operator did not record the following on the operating report: Results for ORP. Instructed PIC document ORP daily.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      Observed the pool equipment is not properly maintained. Observed the UV system is has a small leak. Informed PIC and PIC will get a work order in to fix the leak. Observed eyeball direction flow from the inlets are missing informed PIC and PIC will get replacement parts.

      Correction: Maintain the pool equipment.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical

      HOSING - BACKFLOW PREVENTION DEVICE

      Observed hose bib in wading pools pump room and hose bibs on shower house do not have a backflow preventor devices and hoses are connected. Informed PIC and PIC was able to get 2 of 3 backflow preventors on the hose bibs and will get another.

      Correction: All hose bibs with a hose connected must have a backflow preventor.

      Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION

    • Serious Critical Corrected on site

      GATES AND DOORS WHEN STAFFED

      In a lifeguarded pool area: Gates and doors are not self-closing and latching, and the gates and doors to the pool are not staffed with an attendant and at least one lifeguard present. Observed the gate to the tennis court are not self closing and latching. Public can enter the pool from tennis area.PIC then had a lifeguard staff the enterance. Dicussed with PIC. PIC will have a lifeguard present when tennis classes are occuring when guestcan enter the tennis court from the outside. When classes are not occuring all gates to the outside of the tennis courts will be locked. All guest will then enter the area from main enterance where it is staffed at all times.

      Correction: Provide at least one attendant or lifeguard at the gate or door and at least one lifeguard, or close the pool and lock the gate or door until an attendant and lifeguard can be provided.

      Code ATCP 76.34(4)(b)1. - ENTRY STAFFING IN LIEU OF GATES/DOORS

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      Observed the operator does have the pump curve but does not have which curve is for the pump and drain cover specifications are missing such as lifespan, gpm, and model number. Informed PIC and VGBA cover log will be emailed.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Jul 18, 2025 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  4. Jul 9, 2025 Routine · 3 critical, 14 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is not 80/20 - the valve on the recirculation line for the skimmer was closed.

      Correction: The skimmer line valve was opened to 80% and the main drain line valve was adjusted to 20% flow and corrected during the inspection. Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      SKIMMER COVERS SECURELY SEATED ON DECK

      Skimmer covers not securely seated on deck. The covers were placed into the skimmer opening but were not screwed down and were loosely seated on the deck.

      Correction: Ensure that skimmer covers are securely seated on deck.

      Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK

    • Not serious Non-critical

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      RESPONSIBLE SUPERVISOR INTERLOCK TESTING

      Responsible supervisor is not ensuring that monthly interlock testing is done. Interlock testing is not being done monthly and there is no record of the testing.

      Correction: Have the responsible supervisor ensure that monthly interlock tests are done.

      Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED

      No lifeguard and attendant staffing plan is available.

      Correction: Prepare and maintain a lifeguard staffing plan.

      Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING, SUPERVISION ENCLOSURE MORE THAN ONE POOL

      Where there are lifeguarded and non-lifeguarded pools in an enclosure, the lifeguard and attendant staffing plan does not state the method for periodic supervision.

      Correction: State the method for periodic supervision where there are lifeguarded and non-lifeguarded pools in an enclosure, in the lifeguard and attendant staffing plan.

      Code ATCP 76.22(1)(b)9. UNSTAFFED POOLS IN ENCLOSURE

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical

      RESPONSIBLE SUPERVISOR RECORDS MAINTAIN

      Responsible supervisor is not ensuring that records are maintained. Free/Total Chlorine test results are being recorded in the combined chlorine test results section of the daily operations logs.

      Correction: Have the responsible supervisor ensure that records are maintained.

      Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE

  5. Aug 13, 2024 Re-inspection · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CHEMICAL FEEDERS USED-CAPABLE OF PROVIDING REQUIRED RESIDUAL

      Chlorine feeder is not capable of providing required chemical residual: chlorine is at 13.2 ppm.

      Correction: Install a chemical feeder that is capable of providing the required chemical residual (plan review may be required). Repair or replace chlorine feeder to ensure it is capable of providing and maintaining the appropriate chlorine residual concentration.

      Code ATCP 76.13(1)(b)3. - CAPABLE OF PROVIDING REQUIRED RESIDUAL

    • Serious Critical Repeat

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

  6. Jun 15, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is 7.0.

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical

      SKIMMER BASKET OR WEIR MISSING

      The skimmer weir is missing. Water level is too hig for effective skimming of pool service

      Correction: Replace the missing equipment. Drain water to proper level.

      Code [B] ATCP 76.11(2)(b)

Source: Greendale Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.