Chimney Tour's Guest House
5814 DALE LN, Greendale, WI 53129 · Milwaukee County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Greendale Health Department
- License / ID
- GSAC-C9PKAH
- Status
- Permitted
- Phone
- (414) 397-4076
- Official record
- Greendale Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 0 |
| 2024 | 1 | 6 | 0 |
Inspections
-
Jan 29, 2026 Routine · 6 non-critical
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Priority Foundation
Vomit and diarrheal clean-up - written procedures available
The operator does not have procedures in place for responding to vomiting and diarrheal events.
Correction: Provide procedures that include clean-up methods and actions employees must take to minimize the spread of contamination and the exposure of employees, consumers, food, and surfaces to vomitus or fecal matter. Print out instructions from online and post in employee cleaning areas.
Code ATCP 72.22(4)
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Not serious
Non-critical
Bathroom waste receptacle available
Downstairs toilet room was not provided with a waste receptacle with a lid.
Correction: Each toilet room shall be provided with a waste receptacle with a lid.
Code ATCP 72.17(5)(e)
-
Not serious
Non-critical
Nonabsorbent mattress cover or mattress surface
The mattress in the downstairs bedroom and upstairs daybed is not provided with a nonabsorbent mattress protector that covers the entire sleeping surface.
Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.
Code ATCP 72.20(8)(d)
-
Not serious
Non-critical
Register -provided
A written or electronic register is not available to view during inspection. It is required to have this information available during the inspection.
Correction: Provide a written or electronic register.
Code ATCP 72.24(1)
-
Not serious
Priority Foundation
-
Nov 12, 2024 Routine · 6 non-critical
-
Not serious
Non-critical
PERMIT NOT DISPLAYED IN PUBLIC VIEW
Permit is not displayed conspicuously to the public.
Correction: Post the permit in a conspicuous location to the public.
Code ATCP 72.04 (7)
-
Not serious
Non-critical
REGISTRATION
No register provided or existing register is incomplete.
Correction: Provide a register and require all guests to register their true names and addresses before being assigned sleeping quarters. The register shall be kept intact and available for inspection by the regulatory authority for at least one year.
Code ATCP 72.16
-
Not serious
Non-critical
PLUMBING CROSS-CONNECTIONS
The following cross-connections have been identified: outside water sipgot.
Correction: Provide an air gap or other approved backflow/backsiphonage protection device.
Code [A] ATCP 72.10 (4)
-
Not serious
Non-critical
UTENSIL SANITIZATION - CLEANING PROCEDURES
Dishwasher doen't have a sanitize cycle. Cleaning procedures need to be provided for the guests.
Correction: Operator shall provide written communication that states: " Food and beverage utensils have been provided in this unit as a guest convenience. They have not been sanitized. It is recommened that you wash with a detergent, rinse with clean water and sanitize utensils before their use. To sanitize, after rinsing, add 1 teaspoon of unscented bleach per gallon of clean water and immerse utensils for m
Code [A] ATCP 72.11 (3)(a)
-
Not serious
Non-critical
Corrected on site
ICE-APPROVED SOURCE
Ice trays have ice in them. Unknown water source.
Correction: Dispose of ice in the ice trays. Clean and sanitize the ice trays then store in a clean area protected against contamination.
Code [A] ATCP 72.12 (2)
-
Not serious
Non-critical
Corrected on site
CARBON MONOXIDE DETECTORS - IMPROPERLY LOCATED
Carbon monoxide detector is improperly located near the furnace and water heater
Correction: Provide carbon monoxide detectors in required locations.
Code [B] ATCP 72.145 (3)
-
Not serious
Non-critical
Source: Greendale Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.