Southridge Athletic Club-swimming Pool
6815 W EDGERTON AVE, Greenfield, WI 53220 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Greenfield Health Department
- License / ID
- JPAA-AVSTB5
- Status
- Permitted
- Official record
- Greenfield Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 1 | 12 | 0 |
| 2024 | 1 | 3 | 0 |
Inspections
-
Jun 29, 2026 Routine · 3 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is registering the maximum rate of the flow meter.
Correction: Adjust the flow rate or replace with a bigger registering flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
-
Sep 23, 2025 Routine · 12 non-critical, 2 repeat
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
Skimmers not adjusted to ensure vigorous skimming. The skimmer baskets are mounted to the sides and there are no weir doors.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The current rate for 35,000 gal pool is measured at 80gpm resulting in the turnover rate of 6.82 hr..
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate below 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 60 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. The alkalinity reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
MAX PATRON LOAD POOL
The pool with a shallow end and a deep end maximum patron load posted is incorrect.
Correction: Calculate the maximum patron load to provide at least 15 square feet per patron in the shallow portion and 25 square feet per patron in the deep portion and do not allow maximum patron load to be exceeded.
Code ATCP 76.25(2)(a) - POOL
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area. Only one is available.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is posted twice with different numbers (50 and 65).
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL BASIN ROUTINELY BRUSHED, VACUUMED
Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration. The pool has obvious sediments in the pool bottom.
Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There was cracks and stains.
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
WALLS, CEILINGS, FLOORS
The walls, ceilings and floors in a pool area have not been maintained in clean and sanitary condition. Throughout the facility, ceiling tiles are wet and bulging. The ceiling vents are rusted and moldy.
Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Not serious
Non-critical
-
Aug 21, 2024 Routine · 3 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The whirlpool has 1750 gal of water with the flowrate of 45 gpm which gives the turnover rate at 0.65 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate with the maximum of 0.5 hr (30min).
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Not serious
Non-critical
Source: Greenfield Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.