Inspections

  1. Aug 28, 2026 Admin Follow Up · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the recirculation (turnover) rate has not been met. It is taken 8.7 hours based of the calucation of turnoverate. Instructed PIC to backwash to see if the flowrate increase and or have pool company inspect the sand in the filter if it needs to be cleaned or added. Returned on 8/21/26 for reinspection. Observed the turnoverate is 8.3 hours. PIC stated they recently backwashed.Instructed PIC to talk to pool company on trouble shooting the issue with the turnoverate not meeting 6 hours. ( Second Repeat Violation).

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      FILTER MEDIA INSPECTED ANNUALLY

      Observed filter media is not being inspected annually or cleaned or replaced as necessary. Discussed with PIC if pool company inspected the sand filter and PIC stated they did not. Instructed PIC to have pool company inspect the sand filter.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Observed some areas of the pool deck area not maintained in good repair. Observed some chipping and cracking. Intructed PIC to repair affected areas.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical Repeat

      ELECTRICAL GOOD REPAIR

      Observed the electrical equipment and lighting not maintained in good repair and in operating condition. Observed the pool lights are not operational. Instructed PIC to repair or replace the lights. PIC has concerns of cost of replacing the old lighting.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

  2. Aug 21, 2026 Re-inspection · 1 critical, 7 non-critical, 8 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the recirculation (turnover) rate has not been met. It is taken 8.7 hours based of the calucation of turnoverate. Instructed PIC to backwash to see if the flowrate increase and or have pool company inspect the sand in the filter if it needs to be cleaned or added. Returned on 8/21/26 for reinspection. Observed the turnoverate is 8.3 hours. PIC stated they recently backwashed.Instructed PIC to talk to pool company on trouble shooting the issue with the turnoverate not meeting 6 hours. ( Second Repeat Violation).

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Observed the test kit reagents not replaced as recommended by the manufacturer. Observed the reagents in the taylor test kit haveexpired between 10/25 and 6/26. Instructed PIC to replace the taylor test kit with a new 2006 Taylor test kit. Returned on 8/21/26 for reinspection observed some of the reagents have been replace but not all. PIC stated they are ordering the others. (Second Repeat Violation).

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Observed chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Provided education to PIC and PIC will test twice a week for combined chlorine. Returned on 8/21/26 for reinspection. Observed combined chlorine is not being tested twice a week and recorded. Instructed PIC to test and record combined chlorine.( This is a second repeat violation).

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      CYANURIC TEST

      Observed cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week. Provided education to the PIC and PIC will test cyanuric acid once a week. Returned on 8/21/26 for reinspection. Observed cyanuric acid is not being tested twice a week and recorded. Instructed PIC to test and record cyanuric acid.( This is a second repeat violation).

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical Repeat

      FILTER MEDIA INSPECTED ANNUALLY

      Observed filter media is not being inspected annually or cleaned or replaced as necessary. Discussed with PIC if pool company inspected the sand filter and PIC stated they did not. Instructed PIC to have pool company inspect the sand filter.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Observed some areas of the pool deck area not maintained in good repair. Observed some chipping and cracking. Intructed PIC to repair affected areas.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical Repeat

      ELECTRICAL GOOD REPAIR

      Observed the electrical equipment and lighting not maintained in good repair and in operating condition. Observed the pool lights are not operational. Instructed PIC to repair or replace the lights. PIC has concerns of cost of replacing the old lighting.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      Observed the operator of an existing pool does not have the pump curve or drain cover specifications. Observed there is no pump curve, manfacture name's for VGBA grate, model number, and gpm rating for the VGBA. Instructed PIC to talk to pool company to gather all the missing doucments. Returned on 8/21/26 for reinspection. PIC stated they have called Horizon Pools three times to get the pump curve and VGBA grate information. PIC still has not recieved the information. PIC stated as soon as they get the information they will email it over. ( This is a second repeat violation).

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Aug 7, 2026 Routine · 3 critical, 16 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      Observed the license is not posted for public view. Person In Charge stated they have it posted in the shed to it does get destroyed. Informed PIC the licesne needs to posted in public view. Discussed options on getting post in public view. PIC will post it in public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Observed 1 of 3 weir doors are missing from the skimmers. Informed PIC and PIC stated they will install the missing skimmer.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Observed there is no spare strainer basket for the skimemers. Informed PIC and PIC stated they get a spare.

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      Observed the recirculation (turnover) rate has not been met. It is taken 8.7 hours based of the calucation of turnoverate. Instructed PIC to backwash to see if the flowrate increase and or have pool company inspect the sand in the filter if it needs to be cleaned or added.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      PIPING LABELED, TAGGED OR CODED

      Observed the piping is not labeled with the direction of flow. Instructed PIC to label the direction of water flow on the piping PIC stated they will label the piping.

      Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.

      Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED

    • Not serious Non-critical

      FILTER MEDIA INSPECTED ANNUALLY

      Observed filter media is not being inspected annually or cleaned or replaced as necessary. Discussed with PIC if pool company inspected the sand filter and PIC stated they did not. Instructed PIC to have pool company inspect the sand filter.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical

      DOORS

      Observed the doors to chemical storage area are locked but are not marked to indicate entry is for authorized personnel only. Instructed PIC to post a sign to indicate authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      Observed the operator has not developed and implemented a plan to minimize combined chlorine in the pool. Provided education. PIC will talk to pool company to determine their combined chlorine plan.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      REAGENTS REPLACED

      Observed the test kit reagents not replaced as recommended by the manufacturer. Observed the reagents in the taylor test kit haveexpired between 10/25 and 6/26. Instructed PIC to replace the taylor test kit with a new 2006 Taylor test kit.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      POOL WATER TESTED PEAK PATRON LOAD, PH AND SANITIZER

      Observed pool water not tested for pH and disinfectant at least one other time during the day’s peak patron load. Observed the establishment does not have a controller and is only testing once a day before openning Instructed PIC to test twice a day.

      Correction: Test pool water for pH and disinfectant at least one time during the day’s peak patron load.

      Code ATCP 76.18(1)(a)2 - WATER TESTED, SANITIZER, PH, PEAK LOAD P

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Observed chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Provided education to PIC and PIC will test twice a week for combined chlorine.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      CYANURIC TEST

      Observed cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week. Provided education to the PIC and PIC will test cyanuric acid once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Observed signage or other communication warning against prolonged breath-holding is not posted or otherwise provided. Provided education to PIC and PIC will get the sign posted.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Observed some areas of the pool deck area not maintained in good repair. Observed some chipping and cracking. Intructed PIC to repair affected areas.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      Observed the pool equipment is not properly maintained. Observed pool pump is leaking. PIC is aware and will order a maintance order to repair the pump leak.

      Correction: Maintain the pool equipment [Describe].

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      ELECTRICAL GOOD REPAIR

      Observed the electrical equipment and lighting not maintained in good repair and in operating condition. Observed the pool lights are not operational. Instructed PIC to repair or replace the lights. PIC has concerns of cost of replacing the old lighting.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

    • Serious Critical

      RESPONSIBLE SUPERVISOR ENSURE SAFETY ROPE MAINTAINED

      Observed the responsible supervisor is not ensuring that the safety rope is maintained. Observed safety rope is not attached to the other side of pool to separate shallow end and deep end. PIC stated they will put the rope up.

      Correction: Have the responsible supervisor ensure that the safety rope is in place during required times.

      Code ATCP 76.21 (1)(c)9. - SAFETY ROPE MANAGEMENT

    • Serious Critical Corrected on site

      GATES AND DOORS-SELF-CLOSING

      Observed the gate or door does not self-close. Observed screws missing from one of hinges and hinge is falling off. Informed PIC and PIC had a worker fix the gate. Gate is now self closing.

      Correction: Provide a self-closing gate or door.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      Observed the operator of an existing pool does not have the pump curve or drain cover specifications. Observed there is no pump curve, manfacture name's for VGBA grate, model number, and gpm rating for the VGBA. Instructed PIC to talk to pool company to gather all the missing doucments

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Jul 24, 2025 Routine · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      VGBA DRAIN COVER INFO-INSTALLATION DATE

      The VGBA log or other proof does not indicate drain cover installation date.

      Correction: Indicate in the log of drain cover installation date.

      Code ATCP 76.38(2)(b)5. - INSTALL DATE

    • Serious Critical Repeat

      SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH

      The shepherd's crook is not long enough to effect a rescue in the deepest part of pool.

      Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool.

      Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO

  5. Jun 12, 2024 Routine · 1 critical
    • Serious Critical

      SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH

      The shepherd's crook is not long enough to effect a rescue in the deepest part of pool.

      Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool.

      Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO

  6. Jun 27, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code [B] ATCP 76.27(1)