august-10-2023-fire-agenda-packet
City of Walhalla · Oconee County · meeting of Aug 9, 2023 · Agenda packets
Open the original document More from City of Walhalla
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
“MAIN STREET to the MOUNTAINS”
Mr. Danny Edwards, Mayor
Mr. Danny Woodward, Mayor Pro Tem Mr. Grant Keehn, Councilman
Ms. Sarai Melendez, Councilwoman Mr. David Underwood, Councilman
Mr. Keith Pace, Councilman Mr. Michael Kozlarek, City Attorney
Mr. Tyler Jordan, Councilman Mr. Timothy B. Burton, City Administrator
206 N. Church Street (PO Box 1099), Walhalla SC 29691
864-638-4343 Phone
www.cityofwalhalla.com
AGENDA
WALHALLA FIRE COMMITTEE MEETING
August 10, 2023
5:00 PM
City Hall | 206 N Church St, Walhalla, SC
I. Call to Order and Welcome Chairperson Sarai Melendez
II. Discussion Item: Request for new Pumper Truck (KME Custom)
III. Adjournment
Fire Committee
Sarai Melendez, Chair
David Underwood
Danny Edwards, Mayor, Ex-Officio
Safe Industries
Safe Industries
5031 Highway 153
Easley SC 29642
United States
(864) 845-7175
Quote
Date
8/3/2023
Quote #
EST21580
Bill To
Brandon Burton
Walhalla Fire Department
PO Box 1099
Walhalla SC 29691
United States
Ship To
Walhalla Fire Department
207 E North Broad St
Walhalla SC 29691
United States
Shipping MethodTerms
Net 30
Sales Rep
Cameron Marler
Expires
9/2/2023
Quantity
4
8
4
1
2
4
4
16
Units
Ea
Ea
Ea
Item
A-G1FS442
MD2C4LAR
10175707
10161810
10178557
2P601-10-A5
2
DJ17X50B1
5N
DJ17X50Y1
5N
DJ25X50W2
5N
Description
MSA - G1 SCBA
SYSTEM_PRESSURE 4 4500 PSIG
CYLINDER_CONNECTION 4 CGA
Quick Connect Remote Con
HARNESS 2 Standard wth Chest Strap
CRADLE_TYPE M Metal Band
LUMBAR_TYPE D Adj. Swivel Solid Buckle
REGULATOR_TYPE 2 Solid Cover Left S...
REGULATOR_HOSE_TYPE C Continuous
EMERGENCY_BREATHING_SUPPORT 4
Hose & Pouch
SPEAKER_MODULE L Left Chest
PASS A PASS Right Shoulder
BATTERY_TYPE R Rechargeable
MSA - CYL VLV QC G1 RC 4500 PSIG, 30
MINUTE CYLINDER
MSA - Fcpc, G1, FS, MD, MD NC, 4PT
C-HARN,C-N
MSA - MULTIGAS DETECTOR, ALTAIR
4XR,CONFIGURED (LEL, O2, H2S & CO)
Kochek - 6 X 10 FLEXLITE NH LH,HOSE (PVC)
FireQuip - DJ800 Double Jacket Attack Hose, 1.75“
x 50‘, Blue
FireQuip - DJ800 Double Jacket Attack Hose, 1.75“
x 50‘, Yellow
FireQuip - DJ800 Double Jacket Attack Hose, 2.5“
x 50‘, White-Uncoated
Comments Price
7,885.00
1,080.00
465.00
1,330.00
735.00
164.00
164.00
225.00
Extended
31,540.00
8,640.00
1,860.00
1,330.00
1,470.00
656.00
656.00
3,600.00
Page 1 of 3
Safe Industries
Safe Industries
5031 Highway 153
Easley SC 29642
United States
(864) 845-7175
Page 2 of 3
Quote
Date
8/3/2023
Quote #
EST21580
Quantity
1
2
1
1
1
1
1
1
1
2
1
1
1
2
2
1
1
1
1
4
1
1
Units
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Ea
Item
48264007
48634008
14464005
FA-6
FAP-6
PLY-6AH-B
PLY-10AH-
B
11340
50000
K48-3-P18-P
09
35R2525-H5
2
36R2525-H5
2
CM-2
HTV-12X12
SAC-44-E
1287BRK-L-
2XL
UM12-NF
V18-BL-08-
AC-SP
TFLK55
ULLH-ES
34330004
24204001
Description
Akron - 2.5“ Assault Pistol Grip Nozzle 250G@75P
FM
Akron - Mid-Range Assault Nozzle, 1.5”,
150G@75P
Akron - 2.5“ Shutoff with 1-1/8”“ straight tip w/
pistol grip
Fire Hooks - Flathead Axe, Fiberglass Handle
Fire Hooks - Pickhead Axe, Fiberglass Handle
Leatherhead - Pro-Lite Round: American Hook,
OAL 6‘, HiViz Yellow Pro-Lite Pole, Hollow
Fiberglass Handle, w/ Rubber Bumper
Leatherhead - Pro-Lite Round: American Hook,
OAL 10’ HiViz Yellow Pro-Lite Pole, w/ Rubber
Bumper
Buckeye Extinguishers/Equip. - Extinguisher:
ABC, 10 lb.
Buckeye Extinguishers/Equip. - Extinguisher:
H2O, 2.5 Gal.
Kochek - TRIPLE HOLDER SET -FG-, WRENCH
Kochek - 2.5 NH X 2.5 NH DBL SW RL F
-FG-,ADAPTERS
Kochek - 2.5 NH X 2.5 NH DBL RL M
-FG-,ADAPTERS
Fire Hooks - Connection Mallet
Husky - Salvage Cover: 12 x 12, 10 oz., Vinyl, Red
Zico - 44” Folding Wheel Choc, Easy Grip Handle
ProPak - Traffic Vest: Class II, Lime Mesh, 5-PT
Full Breakaway, Plain, 2XL
TFT - New Force - PRO/Pak - 1 1/2“ angle coupling
100 PSI
Super Vac - 18” Milwaukee Battery PPVs: 18“ PPV ,
2x 8 Ah Bat., 2x AC Chargers, Shore Power
Team Equipment - FLIR K55 320X240 Thermal
Camera Kit
Zico - Assembled bracket with strap & ejector spri...
Akron - Apollo Hi-Riser Dual Inlet Portable and
Deck Monitor with Liftoff, Direct Mount, Ground
Base
Akron - Triple Stacked Tips
Comments Price
725.00
585.00
515.00
74.00
74.00
94.00
140.00
85.00
140.00
120.00
78.00
40.00
22.00
110.00
325.00
20.00
1,275.00
5,650.00
6,595.00
195.00
4,425.00
425.00
Extended
725.00
1,170.00
515.00
74.00
74.00
94.00
140.00
85.00
140.00
240.00
78.00
40.00
22.00
220.00
650.00
20.00
1,275.00
5,650.00
6,595.00
780.00
4,425.00
425.00
Safe Industries
Safe Industries
5031 Highway 153
Easley SC 29642
United States
(864) 845-7175
Page 3 of 3
Quote
Date
8/3/2023
Quote #
EST21580
Quantity
1
5
1
1
1
1
1
3
1
1
Units
Ea
Ea
Ea
Ea
Ea
Item
90400
90500
STC-28-CC-
5BLK
8000-004000
-01
ART.109.261
.1
ART.107.834
.2
ART.105.410
.9
50-11-2855
ART.109.685
.9
Freight
Description
Streamlight - Bank Charger (SC) 120V AC -
Knucklehead/Survivor
Streamlight - Survivor: Right Angle LED Light, w/
Out Charger, Orange
Viewbrite Safety - Collapsible Cone Kit w/ Storage
Bag, Includes five 28“ cones
ZOLL - AED: Semi-Automatic Plus
Genesis - 17C-SL3 eForce
Genesis - eForce 2.0 Ram: 22-54 Telescopic Ram
Genesis - 3 Bay Charger, 120V
Howell Rescue - Milwaukee Battery, 28V 5AH
Genesis - A’ LA CARTE TIPS - RIT Tip (EACH)
Due to continued disruptions in the global supply
chain, fuel surcharges, and fluctuating
freight/shipping charges, we will no longer be able
to estimate nor include any shipping charges on a
quote. Shipping charges will be finalized on the
Invoice. As always, we will continue to provide the
best product pricing as possible but this volatile
market has necessitated a change in our day to day
operations. We hope you understand and continue
to put your trust in Safe Industries.
Comments Price
345.00
95.00
155.00
1,685.00
11,800.00
9,000.00
450.00
250.00
465.00
900.00
Extended
345.00
475.00
155.00
1,685.00
11,800.00
9,000.00
450.00
750.00
465.00
900.00
Total $99,214.00
EST21580
Please note quoted prices are subject to change after expiration date. Quoted prices expire 30 days
from issue date.
Panel Layout
5020-001 Panel Layout
Option Description
LEGEND LOCATION
SW PNL CENTER 12 SW UPR 2010 94"
SIREN CONTROL HEAD WHELEN 295HFS2 LWR LH
PWR POINT DASH MNT (4) BATT DIR
PWR POINT DASH MNT BATT DIR DUAL USB 1.13" HOLE SW PNL
SEAT BELT WARN ADDITIONAL WELDON SEAT BELT INDICATOR MODULE 2010 LH
LOCKED FC94
SWITCH PANEL LH (8) [6+2] SWITCHES 2010 94"
LIGHTBAR SWITCH PANEL -MUX (-010 SW)
FRONT SCENE LIGHT ACTIVATION 'FRONT SCENE' LEGEND
FRONT SCENE LIGHT ACTIVATION ROCKER SWITCH PANEL FRONT SPOTLIGHT
FRONT SCENE LIGHT ACTIVATION ROCKER SWITCH PANEL FRONT FLOOD
HDLT & MRKR LT ACTV DIMMER SW
HDLT & MRKR LT RKR SW 94/96
AUX ENG BRK CTRL ON/OFF SW PNL SWPN (-010)
AUX ENGINE BRAKE CONTROL ON/OFF & HIGH/MED/LOW SWITCH PANEL
WARNING SIDE SWITCH
FRONT WARN SW
MSTR WARN SW PNL 'MASTER'
WINDSHIELD WIPER SYSTEM SINGLE MOTOR
ENGINE HIGH IDLE CONTROL RKR SWITCH
Phone: 877.525.1776
Fax: 888.777.7875
Cell: 724.331.4982
www.clpusa.net
Customer Name:
Sales Representative:
•
•
•
•
•
•Dave Fike
Director-Business Development
davefike@clpusa.net
Thank you for allowing Community Leasing Partners the oppo rtunity to provide this proposal. If you have any
questions regarding the options presented, need additional options, or would like to proceed with a financing, please
contact me at 1-877-525-1776.
Respectively,
SAFE Industries, Cameron Marler
-$ First Payment:
$136,171.02
5.35% 5.19% 5.09%
$102,312.08
750,000.00$
750,000.00$ Payment Frequency:
THERE ARE NO DOCUMENTATION OR CLOSING FEES ASSOCIATED WITH THIS PROPOSAL.
Interest rates are fixed for terms up to 10 years. For terms greater than 10 years, upon receipt of the 7th payment, at sole discretion of the Lessor, the r emaining
payments can be adjusted based on an index determined at contract issuance and then will remain fixed for the remaining term.
$182,577.88
Down Payment:
8 (7-payments)
This proposal has been prepared assuming the lessee is bank qualified and that the proposed lease qualifies for Federal Income Tax Exempt Status for the Lessor
under Section 103 of the IRS Code.
215 S. Seth Child Road
Manhattan, KS 66502
Payment: $291,042.98
August 1, 2024
Annual
5
$172,822.99
Term in Years:
Payment:
7
Total Cost:
Down Payment:
AnnualTotal Cost:
4.99% 4.99%
750,000.00$
Community Leasing Partners, a Division of Community First National Bank , is pleased to present the following
financing options for your review and consideration.
3
$275,721.92
10
One (1) KME Custom Pumper Truck
First Payment:
$96,781.44
Payment Frequency:
-$
750,000.00$ Amount Financed:
Interest Rate: 5.11%
Option 2
August 1, 2025
August 1, 2023
Interest Rate:
Option 1
City of Walhalla, SC (Fire Department)
11 (10-payments)Term in Years: 4 (3-payments) 6 (5-payments)
5.06% 5.04%
$129,160.67
Equipment:
Total:
$750,000.00
$750,000.00
Est. Final Delivery
Amount Financed:
A Division of Community First National Bank - Member FDIC
The quoted interest rate is valid for 10-days from the date of the proposal. T o lock in the interest rate, a credit submission would be required, and a cre dit
approval attained within the same 10-day period. This financing is to be ex ecuted & funded within 30 days of the date of the proposal or Lessor reserves t he
right to adjust the interest rate. The proposal is subject to credit review and approval and mutually acceptable documentation.
ESCROW STRUCTURE
Date Available
Escrow Funding Date:
Interest Earnings in the escrow account have been estimated and used to reduce borrowing cost incurred by the Lessee.
Premature disbursements or delay in funding to the escrow may result in shortage of funds needed to fulfill vendor payments.
August 26, 2023
Total Available Disbursement
March 1, 2024
kmefire.com One Industrial Complex | Nesquehoning, PA 18240
T (800) 235-3928 | P (570) 669-9461
Member of the REV Group
4/27/2023
SAFE Industries
Attn: Cameron Marler/William Gray
REF: GSO# 11694-95 Precon Letter Addendum
Dear Apparatus Committee,
The following is a list of changes, additions, and clarifications discussed to date, post pre-construction
meeting and prior to Final Production Release. Please carefully review this list and return a signed copy
of this letter by 5/4/2023. Delays beyond this timeframe may alter KME’s ability to deliver your
apparatus to contract requirements, may necessitate price increases to the options, or limit our ability
to provide some or all of the changes.
Upon receipt of a signed copy of these documents, the below changes and clarifications will be
amended to the build specification for your apparatus. The list is as follows:
ITEM DESCRIPTION
CUSTOMER
ACCEPTANCE
ACCEPT DECLINE
1
The wheelbase shall be updated from 207” to 211” in accordance
with the engineering driveline pre-check. The overall length of the
apparatus shall be 405” ± 2”.
Respectfully, Customer Authorization
Signature:
Jared Eickhoff Print Name:
Contract Administrator
Title:
Date:
William Gray
Apparatus Regional Manager
4-27-2023
X
KME FIRE APPARATUS
July 13, 2022
GSO# 11694-95
Presented By:
Safe Industries
5031 Hwy. 153
Easley, SC 29642
Phone: 877-997-7233
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 2
PO00025823 - DESIGN CLAUSE
QTY: 1.00
These specifications outline the components, installation methods, and operational characteristics KME is
agreeing to provide in order to meet the purchaser’s requirements. Subject to the terms of the purchase
agreement, other construction details not explicitly listed in these specifications will be determined at the
discretion of the builder. In the event the purchaser desires a different construction or installation not
already described in these specifications, additional charges may apply, and quoted lead time
commitments will be adjusted.
PO00024988 - VEHICLE TRANSPORTATION - DEALER PROVIDED
QTY: 1.00
Transportation for the completed vehicle from KME Fire Apparatus in Nesquehoning, PA to the end user
shall be provided by the sales representative.
PO00011063 - PROPOSED BY - SAFE INDUSTRIES, MARLER
QTY: 1.00
Safe Industries is pleased to offer the proposed vehicle to meet the intent of the fire department
specifications.
KME Fire Apparatus is a leading manufacturer in custom and commercial fire fighting vehicles.
Questions or concerns pertaining to this proposal can be answered by contacting the following KME
representative:
Safe Industries
5031 Hwy. 153
Easley, SC 29642
Fax (864) 845-7176
Cell (864) 245-7937
Cameron Marler
cmarler@safeindustries.com
PO00011108 - PROPOSED SERVICE BY - SAFE INDUSTRIES
QTY: 1.00
KME FIRE APPARATUS SERVICE STATEMENT
Safe Industries is proud to offer over 100 years of combined experience in the fire service and apparatus
industry.
We offer a twenty-four hour service commitment with three(3) service technicians on call and five(5)
service vehicles available.
Our certifications include EVT, Hale, Waterous, Darley, Akron, and Bendix brakes.
We can perform all pump tests at your location with the Draft Commander 3000 mobile pump test trailer,
to eliminate removing your apparatus from your department. In case of an emergency we can UN hook
from the test and have the apparatus in operation in less than 5 minutes.
Safe Industries is fully insured with Workman's Compensation.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 3
Contact:
Safe Industries
5031 Hwy. 153
Easley, SC 29642
Phone:864-845-7175
Fax: 864-845-7176
PO00010968 - PROPRIETARY PARTS
QTY: 1.00
It is the intention of the Purchaser for all bidder's to furnish the apparatus with major parts commonly used
by the heavy-duty truck manufacturers and open market vendors where as replacement parts are more
readily available and at reduced cost. The use of proprietary parts such as but not limited to axles,
suspensions, engines, transmissions, frontal air bags, electronic controls, multiplexing systems, seats,
pumps, gauges, foam systems, etc., may not be acceptable by the purchaser.
PO00010973 - FAIR ETHICAL & LEGAL COMPETITION
QTY: 1.00
In order to ensure fair, ethical, and legal competition, neither original equipment manufacturer (OEM) nor
parent company of the OEM shall have ever been fined or convicted of price fixing, bid rigging, or
collusion in any domestic or international fire apparatus market.
There will be no exceptions.
PO00010974 - NON-COLUSION AGREEMENT
QTY: 1.00
By submission of this bid, each bidder and each person signing on behalf of any bidder, certifies, and in
the case of a joint bid, each party thereof certifies as to its own organization, under penalty of perjury, that
to the best of their knowledge and belief:
The prices in this bid have been arrived at independently without collusion, consultation, communication,
or agreement, for purpose of restricting competition, as to any matter relating to sale price with any other
bidder or any competitor.
Unless otherwise required by law, the prices that have been quoted in this bid have not been knowingly
disclosed by the bidder and shall not knowingly be disclosed by the bidder prior to opening, directly or
indirectly, to any other bidder or to any competitor.
No attempt has been made by the bidder to induce any other person, partnership, or corporation to
submit or not to submit a bid for the purpose of restricting competition.
That all requirements of the law including amendatory provisions as to non-collusive bidding have been
complied with.
PO00010976 - MATERIAL & WORKMANSHIP
QTY: 1.00
All equipment furnished shall be guaranteed to be new and of current manufacture, to meet all
requirements of these specifications.
All workmanship shall be of high quality and accomplished in a professional manner so as to insure a
functional apparatus with a pleasing, aesthetic appearance.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 4
PO00010978 - CONTRACT ADMINISTRATOR
QTY: 1.00
The successful bidder shall designate a contract administrator to provide a single point interface between
the purchaser and the contractor on all matters concerning the contract.
PO00010979 - APPROVAL DRAWING
QTY: 1.00
A detailed drawing of the apparatus shall be provided to the purchaser for approval before construction
begins. A copy of this drawing shall also be provided to the manufacturer's representative. Upon
purchaser's approval, the finalized drawing shall become a part of the total contract.
The drawing shall show, but is not limited to, such items as the chassis make and model, major
components, location of lights, sirens, all compartment locations and dimensions, special suctions,
discharges, etc. The drawing shall be a visual interpretation of the apparatus as it is to be supplied.
PO00010980 - DIGITAL PICTURES
QTY: 1.00
KME will provide, on a weekly or as requested basis, from the time the chassis arrives/begins and
construction of the body compartments begins, "digital" color photos of each phase of construction.
The digital photos shall be e-mailed or otherwise provided to the fire department..
The above specified digital photos shall include, but not be limited to: bare chassis (as it arrives from
chassis factory), modifications to the chassis, installation of the fire pump and its related valves and
piping (prior to being enclosed inside the fire pump cavity), water tank and foam tank (prior to their
installation inside the apparatus body), fabricated apparatus body components (prior to their being
assembled), assembly of the pump compartment fabrications, assembly of the compartmented body
fabrications, installation of the water and foam tanks, interior compartment shelving arrangement, hose
bed arrangement, and assembly of the fire pump control panel.
In addition to the specified photo shots, the purchaser shall have the right to request certain views of
other features and accessories, during their manufacture and installation.
PO00010981 - DELIVERY
QTY: 1.00
Delivery of the apparatus to the customer shall remain the bidder's responsibility.
On initial delivery of the fire apparatus, a qualified and responsible representative of the contractor shall
demonstrate the apparatus and provide initial instruction to representatives of the customer regarding the
operation, care, and maintenance of the apparatus and equipment supplied.
PO00010982 - VEHICLE FLUID PLATE
QTY: 1.00
As required by NFPA-1901, the contractor shall affix a permanent plate in the driver's compartment
specifying the quantity and type of the following fluids used in the vehicle:
A permanent plate in the driving compartment shall specify the quantity and type of the following fluids
used in the vehicle:
• Engine oil
• Engine coolant
• Chassis transmission fluid
• Pump transmission lubrication fluid
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 5
• Pump primer fluid
• Drive axle(s) lubrication fluid
• Air-conditioning refrigerant
• Air-conditioning lubrication oil
• Power steering fluid
• Cab tilt mechanism
• Transfer case fluid
• Equipment rack fluid
• Air compressor system lubricant
• Generator system lubricant
• Aerial systems
PO00010988 - EXACT BLUEPRINT WITH BID
QTY: 1.00
A scale drawing of the specific apparatus being proposed shall be submitted WITH THE BID.
Drawings of similar units or demo units shall not be permitted.
Bidders should be clear that this provision is requiring a SCALE drawing of the truck which is actually
being bid.
The drawing shall be done at the manufacturer's facility by the manufacturer's engineering department in
order to guarantee the accuracy of the drawing.
Failure to comply with this requirement shall be grounds for rejection of the bid!
PO00010990 - FAMA MEMBERSHIP
QTY: 1.00
The apparatus manufacturer must be a current member of the Fire Apparatus Manufacturer's Association
(FAMA).
PO00010992 - MANUFACTURED IN UNITED STATES
QTY: 1.00
The entire apparatus shall be assembled within the borders of the Continental United States to insure
more readily available parts (without added costs and delays caused by tariffs and customs) and service.
PO00010997 - AMP DRAW REPORT
QTY: 1.00
The bidder shall provide with their bid proposal and at the time of delivery, an itemized print out of the
expected amp draw of the entire vehicle's electrical system.
A written load analysis, which shall include the following:
• The rating of the alternator.
• The minimum continuous load of each component that is specified per: Applicable NFPA -1901.
• Additional loads that, when added to the minimum continuous load, determine the total connected
load.
• Each individual intermittent load.
All of the above listed items shall be provided by the bidder per the applicable NFPA-1901.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 6
PO00011001 - COOPERATIVE PURCHASING
QTY: 1.00
The Manufacturer shall be pleased to allow other public agencies to use the purchase agreement
resulting from this invitation to bid unless the bidder expressly notes on the proposal form that prices are
not available for tag-on.
The condition of such use by other agencies shall be that any such agency must make and pursue
contact, purchase order/contract, and all contractual remedies with the successful bidder.
Such tag-ons shall be done so that the original purchasing agency has no responsibility for performance
by either the manufacturer or the agency using the contract.
PO00011002 - PRODUCTION LEVEL ELECTRICAL DRAWINGS
QTY: 1.00
KME shall provide production level harness drawings for the specific unit to be built.
PO00011022 - VEHICLE DATA PLATE DESCRIPTION
QTY: 1.00
The following safety signs shall be provided in the cab:
• A label displaying the maximum number of personnel the vehicle is designed to carry shall be visible
to the driver.
• “Occupants will be seated and belted when apparatus is in motion” signs shall be visible from each
seat.
• “Do Not Move Apparatus When Light Is On” sign adjacent to the warning light indicating a hazard if
the apparatus is moved (as described in subsequent section).
• A label displaying the height, length, and GVWR of the vehicle shall be visible to driver.
• This label shall indicate that the fire department will revise the dimension if vehicle height changes
while vehicle is in service.
The following information shall be on labels affixed to the vehicle:
Fluid Data
• Engine Oil
• Engine Coolant
• Chassis Transmission Fluid
• Pump Transmission Lubrication Fluid
• Pump Primer Fluid (if applicable)
• Drive Axle(s) Lubrication Fluid
• Air Conditioning Refrigerant
• Air Conditioning Lubrication Oil
• Power Steering Fluid
• Cab Tilt Mechanism Fluid
• Transfer Case Fluid (if applicable)
• Equipment Rack Fluid (if applicable)
• Air Compressor System Lubricant
• Generator System Lubricant (if applicable)
• Front Tire Cold Pressure
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 7
• Rear Tire Cold Pressure
• Aerial Hydraulic Fluid (if applicable)
• Maximum Tire Speed Rating
Chassis Data
• Chassis Manufacturer
• Production Number
• Year Built
• Month Manufactured
• Vehicle Identification Number
Manufacturers weight certification:
• Gross Vehicle (or Combination) Weight Rating (GVWR or GCWR)
• Gross Axle Weight Rating, Front
• Gross Axle Weight Rating, Rear
PO00011120 - INSPECTION TRIP (1)
QTY: 1.00
The successful bidder shall provide one (1) factory inspection trip to the apparatus manufacturer's facility.
Transportation, meals, lodging, and other requisite expenses shall be the bidder's responsibility.
PO00011128 - ACCOMMODATIONS FOR THREE (3) FIRE DEPARTMENT PERSONNEL
QTY: 1.00
Accommodations shall be for three (3) Fire Department representatives per trip.
The factory visits shall occur at the following stages of production of the apparatus:
PO00011140 - TRIP ONE (1) AT FINAL COMPLETION
QTY: 1.00
Final inspection upon completion.
PO00011160 - AIR TRANSPORTATION (GREATER THAN 500 MILES)
QTY: 1.00
Travel arrangements greater than 500 miles from the manufacturing facility shall be via commercial airline
transportation.
The {Company} maintains the right to inspect the apparatus, within normal business hours, at any other
point during construction.
Expenses incurred during non-specified inspection visits shall be the responsibility of the {Company}.
During inspection visits, the {Company} reserves the right to conduct actual performance tests to evaluate
completed portions of the unit.
Testing shall be accomplished with the assistance and resources of the contractor.
PO00011181 - COMPLETION INFORMATION
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 8
The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents.
• Owners name and address Apparatus manufacturer, model and serial number
• Chassis make, model and serial number
• Front tire size and total rated capacity in pounds
• Rear tire size and total rated capacity in pounds
• Chassis weight distribution in pounds with water and manufacturer mounted equipment, front and
rear
• Engine make, model, serial number, rated horsepower, rated speed and governed speed
• Type of fuels and fuel tank capacity
• Electrical system voltage and alternator output in amps.
• Battery make, model and total capacity in cold crank amps (CCA)
• Transmission make, model, and serial number. If so equipped chassis transmission PTO(s) make,
model and gear ratio
• Pump make, model, rated capacity in gallons per minute (liters per minute where applicable) and
serial number
• Pump transmission make, model, serial number and gear ratio
• Auxiliary pump make, model, rated capacity in gallons per minute (liters per minute where applicable)
and serial number
• Water tank certified capacity in gallons or liters
• Paint manufacturer and paint number(s)
• Company name and signature of responsible company representative
• Certification of slip resistance of all stepping, standing and walking surfaces.
If the apparatus has a fire pump or an industrial supply pump, the pump manufact urer's certification of
suction capability.
If the apparatus has a fire pump or an industrial supply pump, a copy of the apparatus manufacturer's
approval for stationary pumping applications.
If the apparatus has a fire pump or an industrial supply pump, the engine manufacturers certified brake
horsepower curve for the engine furnished, showing the maximum governed speed.
If the apparatus has a fire pump or an industrial supply pump, the pump manufacturers certification of
hydrostatic test.
If the apparatus has a fire pump or an industrial supply pump, the third party certification of inspection and
test for the fire pump (if applicable).
If the apparatus has an aerial device the third party certification of inspection and test for the aerial
device.
If the apparatus has an aerial device, all the technical information required for inspections to comply with
NFPA 1911, Standards for Testing Fire Department Aerial Devices.
If the apparatus has a fixed line voltage power source, the certification of the test for the fixed power
source (if applicable).
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 9
If the apparatus is equipped with an air system, test results of the air quality, the SCBA fill station, and the
air system installation.
Weight documents from certified scale - showing actual loading on the front axle, rear axle(s) and overall
vehicle (with the water tank full but without personnel, equipment and hose) shall be supplied with the
complete vehicle to determine compliance with NFPA-1901.
Written load analysis and results of electrical performance tests.
If the apparatus is equipped with a water tank, the certification of water tank capacity by the tank
manufacturer.
PO00011182 - FMVSS REQUIREMENT
QTY: 1.00
The chassis shall be certified by the apparatus manufacturer as conforming to all applicable Federal
Motor Vehicle Safety Standards in effect at the date of contract.
This shall be attested to by the attachment of a FMVSS certification label on the vehicle by the contractor
who shall be recognized as the responsible final manufacturer.
PO00011183 - RECORDS
QTY: 1.00
The successful bidder shall be responsible for preparing and maintaining a record file of parts and
assemblies used to manufacture the apparatus.
These records shall be maintained in the factory of the bidder for a minimum of twenty (20) years.
File shall contain copies of any and all reported deficiencies, all replacement parts required to maintain
the apparatus, and original purchase documents including specifications, contract, invoices, incomplete
chassis certificates, quality control reports and final delivery acceptance documents.
The {Company} shall have access to any and all documents contained in this file upon official written
request.
PO00011186 - GENERAL CONSTRUCTION
QTY: 1.00
The complete apparatus, assemblies, subassemblies, component parts, etc., shall be designed and
constructed with the due consideration to the nature and distribution of the load to be sustained and to the
general character of the service to which the apparatus is to be subject.
All parts of the apparatus shall be designed with a factor of safety, which is equal to or greater than that
which is considered standard and acceptable for this class of equipment in fire fighting service.
All parts of the apparatus shall be strong enough to withstand general service under full load.
The apparatus shall be so designed that the various parts and readily accessible for lubrication,
inspection, adjustment and repair.
Bidder's specifications must meet minimum requirements of N.F.P.A. Pamphlet # 1901 and all State and
Federal Department of Transportation vehicle regulations at time of sale of unit.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 10
The apparatus shall be designed and constructed, and the equipment so mounted, with due consideration
to distribution of the load between front and rear axles that all specified equipment, including a full
complement of specified ground ladders, full water tank, loose equipment, and firefighters shall be carried
without overloading or injuring the apparatus.
PO00011188 - PRODUCT LIABILITY
QTY: 1.00
Each bidder shall supply proof of product liability and facility insurance equal to or exceeding
$30,000,000.00.
This shall be provided as part of the proposal. There will be no exceptions.
PO00011192 - PAINT CERTIFICATION
QTY: 1.00
The finish paint shall be certified by the apparatus manufacturer as conforming to all applicable
Commercial Vehicle Paint Standards in effect at the date of contract.
This shall be attested to by the attachment of a Sikkens certification.
PO00023879 - PRICES & PAYMENTS
QTY: 1.00
The bid price will be F.O.B. Destination, on a delivered and accepted basis at the Fire Department.
Total price on KME's proposal sheet will include all items listed in these specifications.
KME has computed pricing less federal and state taxes. It is understood that any applicable taxes will be
added to the proposed prices, unless the purchaser furnishes appropriate tax -exempt forms.
PO00025825 - INSTRUCTION MANUALS - TWO (2) SETS - USB
QTY: 1.00
In accordance with standard commercial practices, applicable to each vehicle (including body and special
equipment) furnished under the contract, the following listed manuals and schematics, in the quantity
specified, shall be provided at time of delivery of each vehicle.
The contractor shall supply at time of delivery, two (2) USB copies of a complete operation and service
manual covering the complete apparatus as delivered and accepted.
The manual shall contain the following:
• Descriptions, specifications, and ratings of chassis, pump (if applicable), and aerial device
• Wiring diagrams
• Lubrication charts
• Operating instructions for the chassis, any major components such as a pump and any auxiliary
systems
• Instructions regarding the frequency and procedures recommended for maintenance
• Parts replacement information
PO00026312 - FC-94 HANDLING
QTY: 1.00
PO00009792 - !!! CRITICAL OVERALL HEIGHT REQUIREMENT !!! - "NO"
QTY: 1.00
PO00009794 - !!! CRITICAL OVERALL LENGTH REQUIREMENT !!! - "NO"
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 11
QTY: 1.00
PO00010995 - NFPA CERTIFICATION
QTY: 1.00
The proposed apparatus will be constructed to withstand the severe and continuous use encountered
during emergency fire fighting services.
The apparatus will be of the latest type, carefully designed and constructed with due consideration to the
nature and distribution of the load to be sustained.
This proposal details the general design criteria of cab and chassis components, aerial device (if
applicable), fire pump and related components (if applicable), water tank (if applicable), fire body,
electrical components, painting, and equipment.
All items of these proposal specifications will conform to the fullest extent possible with the National Fire
Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement-of-Exceptions.
KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical
assistance for the apparatus specified.
PO00011070 - GENERAL INFORMATION - NFPA 1901
QTY: 1.00
The proposed apparatus will be constructed to withstand the severe and continuous use encountered
during emergency fire fighting services. The apparatus will be of the latest type, carefully designed and
constructed with due consideration to the nature and distribution of the load to be sustained.
This proposal details the general design criteria of cab and chassis components, aerial device (if
applicable), fire pump and related components (if applicable), water tank (if applicable), fire body,
electrical components, painting, and equipment.
All items of these proposal specifications will conform to the fullest extent possible with the National Fire
Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement -of-Exceptions.
KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical
assistance for the apparatus specified.
PO00026614 - NFPA TREAD PLATE STEPPING/STANDING/WALKING SURFACE CERTIFICATION
QTY: 1.00
All stepping, standing, and walking surfaces on the body shall meet NFPA #1901 anti-slip standards.
Aluminum tread plate utilized for stepping, standing, and walking surfaces shall be NFPA embossed
compliant.
Upon request by the purchaser, the manufacturer shall supply proof of compliance with this requirement.
PO00026616 - VERTICAL TREAD PLATE - NON-EMBOSSED
QTY: 1.00
The following vertical surfaces on the vehicle (if applicable) shall have non-embossed tread plate:
To include but not limited to:
• Rear of cab overlay
• Rear body overlay
• Front of body overlay
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 12
• Front pump house panel
• Custom cab step well
• Fender overlay
• Fender compartment doors
• Interior cab trim
• Upper body walkway walls
• Rescue body interior (walk-In/walk through)
PO00009789 - "PUMPER FIRE APPARATUS" NFPA 2016 CHAPTERS OF COMPLIANCE
QTY: 1.00
The unit shall be designed to conform fully to the "Pumper Fire Apparatus" requirements as stated in the
NFPA 1901 Standard (2016 Revision), which shall include the following required chapters as stated in
this revision:
• Chapter 1 Administration
• Chapter 2 Referenced Publications
• Chapter 3 Definitions
• Chapter 4 General Requirements
• Chapter 5 Pumper Fire Apparatus
• Chapter 12 Chassis and Vehicle Components
• Chapter 13 Low Voltage Electrical Systems and Warning Devices
• Chapter 14 Driving and Crew Areas
• Chapter 15 Body, Compartments and Equipment Mounting
• Chapter 16 Fire Pumps and Associated Equipment
• Chapter 18 Water Tanks
PO00011169 - NFPA "CHAPTER 16" FIRE PUMP REQUIREMENTS
QTY: 1.00
Chapter 16 Fire Pump and Associated Equipment
PO00010889 - SAFETY SIGNS (NFPA REQUIRED)
QTY: 1.00
Safety sign(s) shall be located on the vehicle at the rear step, and at any cross walkway(s), to warn
personnel that riding in or on these areas while the vehicle is in motion is prohibited.
PO00025814 - THIRD PARTY TESTING
QTY: 1.00
If required by the specific chapters of NFPA-1901, the proposed unit shall be tested and certified by
independent third party inspectors.
All test work for fire pumps outlined in NFPA 1901, Edition shall be conducted.
The third party inspectors shall provide the manufacturer a complete written examination and test report
for each inspection performed at the manufacturer's facility.
This report specifies the points of inspection and results of such examinations and tests.
The inspectors performing the test work on the units are certified to Level II in the required NDT methods,
under the requirements outlined in ASNT document CP-189.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 13
The actual person(s) performing the inspection shall present for review proof of Level II Certification in the
required NDT methods.
The apparatus manufacturer shall designate, in writing, who is qualified to witness and certify these test
results.
Prior to submittal to the automotive fire apparatus manufacturer, the final Report shall be reviewed by the
Supervisor of Fire Equipment Services and a Registered Professional Engineer, both of whom are directly
involved with the aerial device certification program.
When the unit successfully meets all the requirements outlined in NFPA 1901, current edition, the third
party inspector shall issue a Certificate of Automotive Fire Apparatus Examination and Test stating the
unit's compliance with NFPA- 1901.
***SPECIAL: SP00040990 - FC-94 SINGLE AXLE CHASSIS
QTY: 1.00
MODEL
The chassis shall be an FC-94 model. The cab and chassis shall include design considerations for
multiple emergency vehicle applications, rapid transit and maneuverability. The chassis shall be
manufactured for heavy duty service with the strength and capacity to support a fully laden
apparatus, one hundred (100) percent of the time.
MODEL YEAR
The chassis shall have a vehicle identification number that reflects a 2023 model year.
COUNTRY OF SERVICE
The chassis shall be put in service in the country of United States of America (USA).
The chassis will meet applicable U.S.A. federal motor vehicle safety standards per CFR Title 49
Chapter V Part 571 as clarified in the incomplete vehicle book per CFR Title 49 Chapter V Par t 568
Section 4 which accompanies each chassis. The chassis manufacturer is not responsible for
compliance to state, regional, or local regulations. Dealers should identify those regulations and
order any necessary optional equipment from the chassis manufacturer or their OEM needed to
be in compliance with those regulations.
CAB AND CHASSIS LABELING LANGUAGE
The cab and chassis shall include the applicable caution, warning, and safety notice labels with
text to be written in English.
APPARATUS TYPE
The apparatus shall be a pumper vehicle designed for emergency service use which shall be
equipped with a permanently mounted fire pump which has a minimum rated capacity of 750
gallons per minute (3000 L/min). The apparatus shall include a water tank and hose body whose
primary purpose is to combat structural and associated fires.
VEHICLE TYPE
The chassis shall be manufactured for use as a straight truck type vehicle and designed for the
installation of a permanently mounted apparatus behind the cab. The apparatus of the vehicle
shall be supplied and installed by the apparatus manufacturer.
VEHICLE ANGLE OF APPROACH PACKAGE
The angle of approach of the apparatus shall be a minimum of 8.00 degrees.
NFPA1901 Angle of Approach definition:
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 14
“To determine the angle of approach, place a thin steel strip against the front of the tires where
they touch the ground or stretch a tight string from one front tire to the other at the front where
they touch the ground. Determine the lowest point (component or equipment) on the vehicle
forward of the front tire that would make the smallest angle of approach. Hang a plumb bob from
the lowest point and mark the point on the ground where the point of the plumb bob touches.
Measure the vertical distance from the ground to the point where the plumb bob was hung
(distance V). Measure the horizontal distance from the plumb bob point to the steel strip or string
running from front tire to front tire (distance H). Divide the vertical distance by the horizontal
distance. The ratio of V/H is the tangent of the angle of approach. If the ratio is known, the angle
of approach can be determined from a table of trigonometric functions of angles or from a math
calculator. The standard requires a minimum angle of approach of 8.00 degrees: since the
tangent of 8.00 degrees is 0.1405, if V divided by H is 0.1405 or larger, the angle of approach is
8.00 degrees or greater.”
AXLE CONFIGURATION
The chassis shall feature a 4 x 2 axle configuration consisting of a single rear drive axle wit h a
single front steer axle.
GROSS AXLE WEIGHT RATINGS FRONT
The front gross axle weight rating (GAWR) of the chassis shall be 20,000 pounds.
This front gross axle weight rating shall be adequate to carry the weight of the completed
apparatus including all equipment and personnel.
GROSS AXLE WEIGHT RATINGS REAR
The rear gross axle weight rating (GAWR) of the chassis shall be 27,000 pounds.
This rear gross axle weight rating shall be adequate to carry the weight of the completed
apparatus including all equipment and personnel.
PUMP PROVISION
The chassis shall include provisions to mount a drive line pump in the middle of the chassis,
behind the cab, more commonly known as the midship location. Chassis driveline pump
provisions shall include an interlock feature for automatic setting of the park brake when the
vehicle is shifted into pump mode while the transmission is in neutral and the transmission output
speed translates to less than 1 mph. When the conditions are met the driver side par king brake
valve shall activate. Once shifted to road mode the condition for electric automatic brake
engagement is no longer present and the driver’s parking brake control valve shall function
normally.
WATER FOAM TANK CAPACITY
The chassis shall include a carrying capacity of 750 gallons (2839 liters) to 1250 gallons (4732
liters). The water and/or foam tank(s) shall be supplied and installed by the apparatus
manufacturer.
CAB STYLE
The cab shall be a custom, fully enclosed, MFD model with a 10.00 inch raised roof over the driver,
officer, and crew area, designed and built specifically for use as an emergency response vehicle
by a company specializing in cab and chassis design for all emergency response applications.
The cab shall be designed for heavy-duty service utilizing superior strength and capacity for the
application of protecting the occupants of the vehicle. This style of cab shall offer up to eight (8)
seating positions.
The cab shall incorporate a fully enclosed design with side wall roof supports, allowing for a
spacious cab area with no partition between the front and rear sections of the cab. To provide a
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 15
superior finish by reducing welds that fatigue cab metal; the roof, the rear wall and side wall
panels shall be assembled using a combination of welds and proven industrial adhesives
designed specifically for aluminum fabrication for construction.
The cab shall be constructed using multiple aluminum extrusions in conjunction with aluminum
plate, which shall provide proven strength and the truest, flattest body surfaces ensuring less
expensive paint repairs if needed. All aluminum welding shall be completed to the American
Welding Society and ANSI D1.2-96 requirements for structural welding of aluminum.
All interior and exterior seams shall be sealed for optimum noise reduction and to provide the
most favorable efficiency for heating and cooling retention.
The cab shall be constructed of 5052-H32 corrosion resistant aluminum plate. The cab shall
incorporate tongue and groove fitted 6061-T6 0.13 & 0.19 inch thick aluminum extrusions for
extreme duty situations. A single formed, one (1) piece extrusion shall be used for the “A” pillar,
adding strength and rigidity to the cab as well as additional roll-over protection. The cab side
walls and lower roof skin shall be 0.13 inch thick; the rear wall and raised roof skins shall be 0.09
inch thick; the front cab structure shall be 0.19 inch thick.
The exterior width of the cab shall be 94.00 inches wide with a minimum interior width of 88 .00
inches. The overall cab length shall be 131.10 inches with 54.00 inches from the centerline of the
front of the axle to the back of the cab.
The cab interior shall be designed to afford the maximum usable interior space and attention to
ergonomics with hip and legroom while seated which exceeds industry standards. The crew cab
floor shall be flat across the entire walking area for ease of movement inside the cab.
The cab shall offer an interior height of 57.50 inches from the front floor to the headliner in the
non-raised roof area and a rear floor to headliner height of 65.00 inches in the raised roof area, at
a minimum. The cab shall offer an interior measurement at the floor level from the rear of the
engine tunnel to the rear wall of the cab of 51.88 inches. All interior measurements shall include
the area within the interior trimmed surfaces and not to any unfinished surface.
The cab shall include a driver and officer area with two (2) cab doors large enough for personnel
in full firefighting gear. The front doors shall offer a clear opening of 40.25 inches wide X 53.50
inches high, from the cab floor to the top of the door opening. The cab shall also include a crew
area with up to two (2) cab doors, also large enough for personnel in full firefighting gear. The rear
doors shall offer a clear opening of 32.25 inches wide X 61.00 inches high, from the cab floor to
the top of the door opening.
The cab shall incorporate a progressive two (2) step configuration from the ground to th e cab
floor at each door opening. The progressive steps are vertically staggered and extend the full
width of each step well allowing personnel in full firefighting gear to enter and exit the cab easily
and safely.
The first step for the driver and officer area shall measure approximately 11.50 inches deep X
31.13 inches wide. The intermediate step shall measure approximately 8.50 inches deep X 32.50
inches wide. The height from the first step to the intermediate step and the intermediate step to
the cab floor shall not exceed 11.00 inches.
The first step for the crew area shall measure approximately 11.50 inches deep X 20.44 inches
wide. The intermediate step shall measure approximately 10.25 inches deep X 22.75 inches
wide. The height from the first step to the intermediate step and the intermediate step to the cab
floor shall not exceed 12.80 inches.
CAB FRONT FASCIA
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 16
The front cab fascia shall be constructed of 5052-H32 Marine Grade, 0.13 of an inch thick plate
which shall be an integral part of the cab.
The cab fascia will encompass the entire front of the aluminum cab structure from the bottom of
the windshield to the bottom of the cab and shall be the “Classic” design.
The front cab fascia shall include two (2) modules on each side accommodating a total of up to
four (4) Hi/Low beam headlights and two (2) turn signal lights or up to four (4) warning lights. Two
(2) chrome plated bezels shall be provided on each side around each set of two lamps.
FRONT GRILLE
The front fascia shall include a 304 stainless steel front grille.
CAB UNDERCOAT
There shall be a rubberized undercoating applied to the underside of the cab that provides
abrasion protection, sound deadening and corrosion protection.
CAB SIDE DRIP RAIL
There shall be a drip rail along the top radius of each cab side. The drip rails shall help prevent
water from the cab roof running down the cab side.
CAB PAINT EXTERIOR
The cab shall be painted prior to the installation of glass accessories and all other cab trim to
ensure complete paint coverage and the maximum in corrosion protection of all metal surfaces.
All metal surfaces on the entire cab shall be ground by disc to remove any surface oxidation or
surface debris which may hinder the paint adhesion. Once the surface is machine ground a high
quality acid etching of base primer shall be applied. Upon the application of body fillers and their
preparation, the cab shall be primed with a coating designed for corrosion resistance and surface
paint adhesion. The maximum thickness of the primer coat shall be 2.00 mils.
The entire cab shall then be coated with an intermediate solid or epoxy surfacing agent that is
designed to fill any minor surface defects, provide an adhesive bond between the primer and the
paint and improve the color and gloss retention of the color. The finish to this procedure shall be
a sanding of the cab with 360 grit paper followed by sealing the seams with SEM brand seam
sealer.
The cab shall then be painted the specific color designated by the customer with an acrylic
urethane type system designed to retain color and resist acid rain and most atmospheric
chemicals found on the fire ground or emergency scene. The paint shall have a minimum
thickness of 2.00 mils, followed by a clear top coat not to exceed 2.00 mils. The entire cab shall
then be baked at 180 degrees for one (1) hour to speed the curing process of the coatings.
CAB PAINT MANUFACTURER
The cab shall be painted with Sikkens paint.
CAB PAINT PRIMARY/LOWER COLOR
The primary/lower paint color shall be Sikkens FLNA 31979 Red.
CAB PAINT WARRANTY
Purchaser shall receive a Paint and Finish (Exterior Clear coated) One (1) Year limited warranty in
accordance with, and subject to, warranty certificate RFW0701. The warranty certificate is
incorporated by reference into this proposal, and included with this proposal or available upon
request.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 17
CAB PAINT INTERIOR
The visible interior cab structure surfaces shall be painted with a multi-tone silver gray texture
finish.
CAB ENTRY DOORS
The cab shall include four (4) entry doors, two (2) front doors and two (2) crew doors designed for
ease of entering and egress when outfitted with an SCBA. The doors shall be constructed of
extruded aluminum with a nominal thickness of 0.13 inch. The exterior skins shall be constructed
of 0.13 inch aluminum plate.
The doors shall include a double rolled style automotive rubber seal around the perimeter of each
door frame and door edge which ensures a weather tight fit.
All door hinges shall be hidden within flush mounted cab doors for a pleasing smooth appearance
and perfect fit along each side of the cab. Each door hinge shall be piano style with a 0.38 inch
pin and shall be constructed of stainless steel.
CAB ENTRY DOOR TYPE
All cab entry doors shall be barrier clear design resulting in exposed lower cab steps. The doors
shall provide approximately 32.00 inches of clearance from the ground to the bottom of the door
so cab doors may be opened un-hindered by most obstacles encountered, such as guard rails
along interstate highways.
Entry doors shall include Pollak mechanical plunger style switches for electrical component
activation.
CAB INSULATION
The cab ceiling and walls shall include a nonwoven polyester fiber insulation. The insulation shall
act as a barrier absorbing noise as well as assisting in sustaining the desired climate within the
cab interior.
CAB STRUCTURAL WARRANTY
Purchaser shall receive a Cab Structure (Aluminum) Five (5) Years limited warranty in accordance
with, and subject to, warranty certificate RFW0601. The warranty certificate is incorporated by
reference into this proposal, and included with this proposal or available upon request.
CAB TEST INFORMATION
The cab shall have successfully completed the preload side impact, static roof load application
and frontal impact without encroachment to the occupant survival space when tested in
accordance with Section 4 of SAE J2420 COE Frontal Strength Evaluation Dynamic Loading
Heavy Trucks, Section 5 of SAE J2422 Cab Roof Strength Evaluation Quasi –Static Loading Heavy
Trucks and ECE R29 Uniform Provisions Concerning the Approval of Vehicles with regard to the
Protection of the Occupants of the Cab of a Commercial Vehicles Annex 3 Paragraph 5.
The above tests have been witnessed by and attested to by an independent third party. The test
results were recorded using cameras, high speed imagers, accelerometers and strain gauges.
Documentation of the testing shall be provided upon request.
ELECTRICAL SYSTEM
The chassis shall include a single starting electrical system which shall include a 12 volt direct
current multiplexing system, suppressed per SAE J551. The wiring shall be appropriate gauge
cross link with 311 degree Fahrenheit insulation. All SAE wires in the chassis shall be color
coded and shall include the circuit number and function where possible. The wiring shall be
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 18
protected by 275 degree Fahrenheit minimum high temperature flame retardant loom. All nodes
and sealed Deutsch connectors shall be waterproof.
DATA RECORDING SYSTEM
The chassis shall have a Weldon Vehicle Data Recorder (VDR) system installed. The system shall
be designed to meet NFPA 1901 and shall be integrated with the Weldon Multiplex electrical
system. The following information shall be recorded:
• Vehicle Speed
• Acceleration
• Deceleration
• Engine Speed
• Engine Throttle Position
• ABS Event
• Seat Occupied Status
• Seat Belt Status
• Master Optical Warning Device Switch Position
• Time
• Date
Each portion of the data shall be recorded at the specified intervals and stored for the specified
length of time to meet NFPA 1901 guidelines and shall be retrievable by connecting a laptop
computer to the VDR system. The laptop connection shall be a panel mounted female type B USB
connection point, remotely mounted in the left side foot well.
LOAD MANAGEMENT SYSTEM
The apparatus load management shall be performed by the included multiplex system. The
multiplex system shall also feature the priority of sequences and shall shed electrical loads based
on the priority list specifically programmed.
ACCESSORY POWER
The electrical distribution panel shall include two (2) power studs. The studs shall be size #10 and
each of the power studs shall be circuit protected with a fuse of the specified amperage. One (1)
power stud shall be capable of carrying up to a 40 amp battery direct load. One (1) power stud
shall be capable of carrying up to a 15 amp ignition switched load. The two (2) power studs shall
share one (1) #10 ground stud. A 225 amp battery direct power and ground stud shall be provided
and installed on the chassis near the left hand battery box for OEM body connections.
EXTERIOR ELECTRICAL TERMINAL COATING
All terminals exposed to the elements will be sprayed with a high visibility protective ru bberized
coating to prevent corrosion.
ELECTRICAL SYSTEM WARRANTY
Purchaser shall receive an Electrical System One (1) Year or 18,000 Miles limited warranty in
accordance with, and subject to, warranty certificate RFW0201. The warranty certificate is
incorporated by reference into this proposal, and included with this proposal or available upon
request.
ENGINE
The chassis engine shall be a Cummins L9 engine. The L9 engine shall be an in -line six (6)
cylinder, four cycle diesel powered engine. The engine shall offer a rating of 450 horse power at
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 19
2100 RPM and shall be governed at 2200 RPM. The torque rating shall feature 1250 foot pounds of
torque at 1200 RPM with 543 cubic inches (8.9 liters) of displacement.
The L9 engine shall feature a VGT™ Turbocharger, a high pressure common rail fuel system, fully
integrated electronic controls with an electronic governor, and shall be EPA certified to meet the
2021 emissions standards using cooled exhaust gas recirculation and selective catalytic
reduction technology.
The engine shall include an engine mounted combination full flow/by-pass oil filter with
replaceable spin on cartridge for use with the engine lubrication system. The engine shall include
Citgo brand Citgard 500, or equivalent SAE 15W40 CK-4 low ash engine oil which shall be utilized
for proper engine lubrication.
A wiring harness shall be supplied ending at the back of the cab. The harness shall include a
connector which shall allow an optional harness for the pump panel. The included circuits shall
be provided for a tachometer, oil pressure, engine temperature, hand throttle, high idle and a PSG
system. A circuit for J1939 data link shall also be provided at the back of the cab.
CAB ENGINE TUNNEL
The cab interior shall include an integrated engine tunnel constructed of 5052-H32 Marine Grade,
0.19 of an inch thick aluminum. The tunnel shall be a maximum of 41.50 inches wide X 25.50
inches high.
DIESEL PARTICULATE FILTER CONTROLS
There shall be two (2) controls for the diesel particulate filter. One (1) control shall be for
regeneration and one (1) control shall be for regeneration inhibit.
ENGINE PROGRAMMING HIGH IDLE SPEED
The engine high idle control shall maintain the engine idle at approximately 1250 RPM when
engaged.
ENGINE HIGH IDLE CONTROL
The vehicle shall be equipped with a high-idle speed rocker switch and an automatic high-idle
speed control. It shall be pre-set so when activated, it will operate the engine at the appropriate
RPM to increase alternator output. This device shall operate only when the engine is running and
the transmission is in neutral with the parking brake set. When automatically engaged the high
idle shall disengage when the operator depresses the brake pedal, or the transmission is placed
in gear, and shall be available to manually or automatically re-engage when the brake is released,
or when the transmission is placed in neutral.
ENGINE PROGRAMMING ROAD SPEED GOVERNOR
The engine shall include programming which will govern the top speed of the vehicle.
AUXILIARY ENGINE BRAKE
A compression brake, for the six (6) cylinder engine shall be provided. A cutout relay shall be
installed to disable the compression brake when in pump mode or when an ABS event
occurs. The engine compression brake shall activate upon 0% accelerator when in operation
mode and actuate the vehicle’s brake lights.
The engine shall utilize a variable geometry turbo (VGT) as an integrated auxiliary engine brake to
offer a variable rate of exhaust flow, which when activated in conjunction with the compression
brake shall enhance the engine's compression braking capabilities.
AUXILIARY ENGINE BRAKE CONTROL
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 20
An engine compression brake control device shall be included. The electronic control device shall
monitor various conditions and shall activate the engine brake only if all of the following
conditions are simultaneously detected:
• A valid gear ratio is detected.
• The driver has requested or enabled engine compression brake operation.
• The throttle is at a minimum engine speed position.
• The electronic controller is not presently attempting to execute an electronically controlled
final drive gear shift.
The compression brake shall be controlled through an on/off switch and a low/medium/high
selector switch.
ELECTRONIC ENGINE OIL LEVEL INDICATOR
The engine oil shall be monitored electronically and shall send a signal to activate a warning in
the instrument panel when levels fall below normal. The warning shall activate in a low oil
situation upon turning on the master battery and ignition switches without the engine running.
FLUID FILLS
The engine oil, coolant, transmission, and power steering fluid fills shall be located under the
cab. The windshield washer fill shall be accessible through the front left side mid step.
ENGINE DRAIN PLUG
The engine shall include an original equipment manufacturer installed oil drain plug.
ENGINE WARRANTY
The Cummins engine shall be warranted for a period of five (5) years or 100,000 miles, whichever
occurs first.
REMOTE THROTTLE HARNESS
An apparatus interface wiring harness for the engine and transmission pump interlocks shall be
supplied with the chassis. The harness shall include a connector for connection to a chassis
pump panel harness supplied by the body builder and shall terminate in the left frame rail behind
the cab for connection by the body builder. The harness shall include circuits deemed for a pump
panel and shall contain circuits for a hand throttle, and a multiplexed gauge. Separate circuits
shall also be included for a pump control switch, “Pump Engaged” and “OK to Pump” indicator
lights, open compartment ground, start signal, park brake ground, ignition signal, master power,
clean power, customer ignition, air horn solenoid switch, high idle switch and high idle indicator
light. The harness shall contain interlocks that will prevent shifting to road or pump mode unless
the transmission output speed translates to less than 1 mph and the transmission is in neutral.
The shift to pump mode shall also require the park brake be set.
ENGINE PROGRAMMING REMOTE THROTTLE
The engine ECM (Electronic Control Module) discreet wire remote throttle circuit shall be turned
off for use with a J1939 based pump controller or when the discreet wire remote throttle contro ls
are not required.
ENGINE PROGRAMMING IDLE SPEED
The engine low idle speed will be programmed at 700 rpm.
ENGINE AIR INTAKE
The engine air intake system shall include an ember separator. This ember separator shall be
designed to protect the downstream air filter from embers using a combination of unique flat and
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 21
crimped metal screens packaged in a heavy duty galvanized steel frame. This multilayered screen
shall trap embers and allow them to burn out before passing through the pack.
The engine air intake system shall also include an air cleaner mounted above the radiator. This air
cleaner shall utilize a replaceable dry type filter element designed to prevent dust and debris from
being ingested into the engine. A service cover shall be provided on the housing, reducing the
chance of contaminating the air intake system during air filter service.
The air intake system shall include a restriction indicator light in the warning light cluster on the
instrument panel, which shall activate when the air cleaner element requires replacement.
ENGINE FAN DRIVE
The engine cooling system fan shall incorporate a thermostatically control led, Horton fully
variable type fan drive with SmartClutch J-1939 CAN controller.
The variable speed fan clutch only engages at the amount needed for proper cooling to facilitate
improved vehicle performance, cab heating in cold climates, and fuel econom y. The fan clutch
design shall be fail-safe so that if the clutch drive fails the fan shall engage to prevent engine
overheating due to the fan clutch failure. The fan speed shall include a J-1939 CAN clutch
controller to receive signal from the engine control module to activate at variable rates of speed.
Variable speeds shall be set through thermostatic and engine speed signals to run as efficiently
and quietly as required to maintain temperature.
ENGINE COOLING SYSTEM
There shall be a heavy-duty aluminum cooling system designed to meet the demands of the
emergency response industry. The cooling system shall have the capacity to keep the engine
properly cooled under all conditions of road and pumping operations. The cooling system shall
be designed and tested to meet or exceed the requirements specified by the engine and
transmission manufacturer and all EPA requirements. The complete cooling system shall be
mounted to isolate the entire system from vibration or stress. The individual cores of the coo ling
system shall be mounted in a manner to allow expansion and contraction at various rates without
inducing stress into the adjoining cores.
The cooling system shall be comprised of a charge air cooler to radiator serial flow package that
provides the maximum cooling capacity for the specified engine as well as serviceability. The
main components shall include a surge tank, a charge air cooler bolted to the front of the radiator,
recirculation shields, a shroud, a fan, and required tubing.
The radiator shall be a down-flow design constructed with aluminum cores, plastic end tanks, and
a steel frame. The radiator shall be equipped with a drain cock to drain the coolant for
serviceability.
The cooling system shall include a one piece injected molded polymer fan with a three (3) piece
fiberglass fan shroud.
The cooling system shall be equipped with a surge tank that is capable of removing entrained air
from the system. The surge tank shall be equipped with a low coolant probe and rearward
oriented sight glass to observe coolant in the system. A cold fill and observation line shall be
included within the frame mounted translucent recovery bottle to monitor the level of the coolant.
The surge tank shall have a dual seal cap that meets the engine manufacturer's pressure
requirements and allows for expansion and recovery of coolant into a separate integral expansion
chamber.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 22
All radiator tubes shall be formed from aluminized steel tubing. Recirculation shields shall be
installed where required to prevent heated air from reentering the cooling package and affecting
performance.
The charge air cooler shall be a cross-flow design constructed completely of aluminum with cast
tanks. All charge air cooler tubes shall be formed from aluminized steel tub ing and installed with
silicone hump hoses and stainless steel “constant torque” style clamps meeting the engine
manufacturer's requirements.
The radiator and charge air cooler shall be removable through the bottom of the chassis.
ENGINE COOLING SYSTEM PROTECTION
The engine cooling system shall include a recirculation shield designed to act as a light duty skid
plate below the radiator to provide additional protection for the engine cooling system from light
impacts, stones, and road debris.
ENGINE COOLANT
The cooling package shall include Extended Life Coolant (ELC). The use of ELC provides longer
intervals between coolant changes over standard coolants providing improved performance. The
coolant shall contain a 50/50 mix of ethylene glycol and de-ionized water to keep the coolant from
freezing to a temperature of -34 degrees Fahrenheit.
Proposals offering supplemental coolant additives (SCA) shall not be considered, as this is part of
the extended life coolant makeup.
ELECTRONIC COOLANT LEVEL INDICATOR
The instrument panel shall feature a low engine coolant indicator light which shall be located in
the center of the instrument panel. An audible tone alarm shall also be provided to warn of a low
coolant incident.
ENGINE PUMP HEAT EXCHANGER
A single bundle type coolant to water heat exchanger shall be installed between the engine and
the radiator. The heat exchanger shall be designed to prohibit water from the pump from coming
in contact with the engine coolant. This shall allow the use of water from the discharge side of the
pump to assist in cooling the engine.
COOLANT HOSES
The cooling systems hose shall be formed silicone hose and formed aluminized steel tubing and
include stainless steel constant torque band clamps.
ENGINE COOLANT OVERFLOW BOTTLE
A remote engine coolant overflow expansion bottle shall be provided in the case of over filling the
coolant system. The overflow bottle shall capture the expansion fluid or overfill rather than allow
the fluid to drain on the ground.
ENGINE EXHAUST SYSTEM
The exhaust system shall include an end-in end-out horizontally mounted single module after
treatment device, and downpipe from the charge air cooled turbo. The single module shall
include four temperature sensors, diesel particulate filter (DPF), urea dosing module (UL2), and a
selective catalytic reduction (SCR) catalyst to meet current EPA standards. The selective catalytic
reduction catalyst utilizes a diesel exhaust fluid solution consisting of urea and purified water to
convert NOx into nitrogen, water, and trace amounts of carbon dioxide. The solution shall be
mixed and injected into the system through the DPF and SCR.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 23
The system shall utilize 0.07 inch thick stainless steel exhaust tubing between the engine turbo
and the DPF. Zero leak clamps seal all system joints between the turbo and DPF.
The single module after treatment through the end of the tailpipe shall be connected with zero
leak clamps. The discharge shall terminate horizontally on the right side of the vehic le ahead of
the rear tires.
The exhaust system after treatment module shall be mounted below the frame in the outboard
position.
DIESEL EXHAUST FLUID TANK
The exhaust system shall include a molded cross linked polyethylene tank for Diesel Exhaust
Fluid (DEF). The tank shall have a capacity of six (6) usable gallons and shall be mounted on the
left hand side of the chassis frame behind the batteries below the frame. The tank shall have a fill
with splash guard on the battery box under the cab for access when the cab is tilted.
The DEF tank shall be designed with capacity for expansion in case of fluid freezing. Engine
coolant, which shall be thermostatically controlled, shall be run through lines in the tank to help
prevent the DEF from freezing and to provide a means of thawing the fluid if it should become
frozen.
ENGINE EXHAUST ACCESSORIES
An exhaust temperature mitigation device shall be shipped loose for installation by the body
manufacturer on the vehicle. The temperature mitigation device shall lower the temperature of the
exhaust by combining ambient air with the exhaust gasses at the exhaust outlet.
ENGINE EXHAUST WRAP
The exhaust tubing between the engine turbo and the diesel particulate filter (DPF) shall be
wrapped with a thermal cover in order to retain the necessary heat for DPF regeneration. The
exhaust wrap shall also help protect surrounding components from radiant heat which can be
transferred from the exhaust.
The exhaust flex joint shall not include the thermal exhaust wrap.
EMISSIONS SYSTEMS WARRANTY
Purchaser shall receive a Regulated Emissions Systems Five (5) Years or 100,000 Miles limited
warranty in accordance with, and subject to, warranty certificate RFW0140. The warranty
certificate is incorporated by reference into this proposal, and included with this proposal or
available upon request.
TRANSMISSION
The drive train shall include an Allison model EVS 3000 torque converting, automatic
transmission which shall include electronic controls. The transmission shall feature two (2) 10-
bolt PTO pads located on the converter housing.
The transmission shall include two (2) internal oil filters and Castrol TranSynd ™ synthetic TES
295 transmission fluid which shall be utilized in the lubrication of the EVS transmission. An
electronic oil level sensor shall be included with the readout located in the shift selector.
The transmission gear ratios shall be:
1st 3.49:1
2nd 1.86:1
3rd 1.41:1
4th 1.00:1
5th 0.75:1
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 24
6th 0.65:1 (if applicable)
Rev 5.03:1
TRANSMISSION MODE PROGRAMMING
The transmission, upon start-up, will select a six (6) speed operation without the need to press the
mode button.
TRANSMISSION FEATURE PROGRAMMING
The Allison Gen V/VI-E transmission EVS group package number 127 shall contain the 198
vocational package in consideration of the duty of this apparatus as a pumper. This package
shall incorporate an automatic neutral with selector override. This feature commands the
transmission to neutral when the park brake is applied, regardless of drive range requested on the
shift selector. This requires re-selecting drive range to shift out of neutral for the override.
This package shall be coupled with the use of a split shaft PTO and incorporate pumping
circuits. These circuits shall be used allowing the vehicle to operate in the fourth range lockup
while operating the pump mode due to the 1 to 1 ratio through the transmission, therefore the
output speed of the engine is the input speed to the pump. The pump output can be easily
calculated by using this input speed and the drive ratio of the pump itself to rate the gallons of
water the pump can provide.
A transmission interface connector shall be provided in the cab. This package shall contain the
following input/output circuits to the transmission control module. The Gen V/VI-E transmission
shall include prognostic diagnostic capabilities. These capabilities shall include the monitoring of
the fluid life, filter change indication, and transmission clutch maintenance.
Function ID Description Wire assignment
Inputs
C PTO Request 142
J Fire Truck Pump Mode (4th Lockup) 122 / 123
Outputs
C Range Indicator 145 (4th)
G PTO Enable Output 130
Signal Return 103
ELECTRONIC TRANSMISSION OIL LEVEL INDICATOR
The transmission fluid shall be monitored electronically and shall send a signal to activate a
warning in the instrument panel when levels fall below normal.
TRANSMISSION SHIFT SELECTOR
An Allison pressure sensitive range selector touch pad shall be provided and located to the right
of the driver within clear view and easy reach. The shift selector shall have a graphical Vacuum
Florescent Display (VFD) capable of displaying two lines of text. The shift selector shall provide
mode indication and a prognostic indicator (wrench symbol) on the digital display. The
prognostics monitor various operating parameters and shall alert you when a specific
maintenance function is required.
TRANSMISSION PRE-SELECT WITH AUXILIARY BRAKE
When the auxiliary brake is engaged, the transmission shall automatically shift to second gear to
decrease the rate of speed assisting the secondary braking system and slowing the vehicle.
TRANSMISSION COOLING SYSTEM
The transmission shall include a water to oil cooler system located in the cooling loop between
the radiator and the engine. The transmission cooling system shall meet all transmission
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 25
manufacturer requirements. The transmission cooling system shall feature continuous flow of
engine bypass water to maintain uninterrupted transmission cooling.
TRANSMISSION DRAIN PLUG
The transmission shall include an original equipment manufacturer installed magnetic
transmission fluid drain plug.
TRANSMISSION WARRANTY
The Allison EVS series transmission shall be warranted for a period of five (5) years with unlimited
mileage. Parts and labor shall be included in the warranty.
PTO LOCATION
The transmission shall have two (2) power take off (PTO) mounting locations, one (1) in the 8:00
o’clock position and one (1) in the 4:00 o’clock position.
DRIVELINE
All drivelines shall be heavy duty metal tube and equipped with MSI 1710 series universal
joints. The shafts shall be dynamically balanced prior to installation to alleviate future
vibration. In areas of the driveline where a slip shaft is required, the splined slip joint shall be
coated with Glide Coat®. The drivelines shall include Meritor brand u-joints with thrust washers.
MIDSHIP PUMP / GEARBOX
A temporary jackshaft driveline shall be installed by the chassis manufacturer to accommodate
the mid-ship split shaft pump as specified by the apparatus manufacturer.
MIDSHIP PUMP / GEARBOX MODEL
The midship pump/gearbox provisions shall be for a Hale DSD forward pump.
MIDSHIP PUMP GEARBOX DROP
The Hale pump gearbox shall have an “L” (long) drop length.
MIDSHIP PUMP RATIO
The ratio for the midship pump shall be 2.28:1 (23).
MIDSHIP PUMP LOCATION C/L SUCTION TO C/L REAR AXLE
The midship pump shall be located so the dimension from the centerline of the suction to the
centerline of the rear axle is 100.00 inches.
PUMP SHIFT CONTROLS
One (1) air pump shift control panel shall be located on the left hand side of the engine tunnel,
integrated with the shifter pod. The following shall be provided on the panel: a three (3) position
control lever; an engraved PUMP ENGAGED identification light; and an engraved OK TO PUMP
identification light. The pump shift control panel shall be black with a yellow border outline and
shall include pump instructions. An instruction plate describing the transmission shift selector
position used for pumping shall be provided and located so it can be read from the driver’s
position per NFPA 16.10.1.3. The road mode shall be selected when the control lever is in the
forward position and pump mode shall be selected when the control lever is in the rearwa rd
position.
The control lever center position shall exhaust air from both pump and road sides of the pump
gear box shift cylinder.
PUMP SHIFT CONTROL PLUMBING
Air connections shall be provided from the air supply tank to the pump shift control valve a nd
from the pump shift control valve to the frame mounted bracket. The frame mounted bracket shall
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 26
include labeling identifying the pump and road connection points with threaded 0.25 inch NPT
fittings on the solenoid for attaching the customer installed pump. The air supply shall be
pressure protected from service brake system.
FUEL FILTER/WATER SEPARATOR
The fuel system shall have a Fleetguard FS20121 fuel filter/water separator as a primary filter. The
fuel filter shall have a drain valve.
A water in fuel sensor shall be provided and wired to an instrument panel lamp and audible alarm
to indicate when water is present in the fuel/water separator.
A secondary fuel filter shall be included as approved by the engine manufacturer.
FUEL LINES
The fuel system supply and return lines installed from the fuel tank to the engine shall be
reinforced nylon tubing rated for diesel fuel. The fuel lines shall be brown in color and connected
with brass fittings.
ELECTRIC FUEL PRIMER
Integral to the engine assembly is an electric lift pump that serves the purpose of pre-filter fuel
priming.
FUEL TANK
The fuel tank shall have a capacity of fifty (50) gallons and shall measure 35.00 inches in width X
15.00 inches in height X 24.00 inches in length.
The baffled tank shall have a vent port to facilitate venting to the top of the fill neck for rapid filling
without "blow-back" and a roll over ball check vent for temperature related fuel expansion and
draw.
The tank is designed with dual draw tubes and sender flanges. The tank shall have 2.00 inch NPT
fill ports for right or left hand fill. A 0.50 inch NPT drain plug shall be centered in the bottom of the
tank.
The fuel tank shall be mounted below the frame, behind the rear axle. Two (2) three-piece strap
hanger assemblies with “U” straps bolted midway on the fuel tank front and rear shall be utilized
to allow the tank to be easily lowered and removed for service purposes. Rubber isolating pads
shall be provided between the tank and the upper tank mounting brackets. Strap mounting studs
through the rail, hidden behind the body shall not be acceptable.
FUEL TANK MATERIAL AND FINISH
The fuel tank shall be constructed of 12 gauge aluminized steel. The exterior of the tank shall be
powder coated black and then painted to match the frame components.
All powder coatings, primers and paint shall be compatible with all metals, pretreatments and
primers used. The cross hatch adhesion test per ASTM D3359 Method B, results to be 5B
minimum. The pencil hardness test per ASTM D3363 shall have a final post-curved pencil
hardness of H-2H. The direct impact resistance test per ASTM D2794, results to be 5B minimum.
Any proposals offering painted fuel tanks with variations from the above process shall not be
accepted. The film thickness of vendor supplied parts shall also be sufficient to meet the
performance standards as stated above.
FUEL TANK STRAP MATERIAL
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 27
The fuel tank straps shall be constructed of ASTM A-36 steel. The fuel tank straps shall be powder
coated black and then painted to match the frame components if possible.
FUEL TANK FILL PORT
The fuel tank fill ports shall be offset with the left fill port located in the rearward position and the
right fill port located in the middle position on the fuel tank.
FUEL TANK DRAIN PLUG
A 0.5 inch NPT magnetic drain plug shall be centered in the bottom of the fuel tank.
FRONT AXLE
The front axle shall be a Meritor Easy Steer Non drive front axle, model number MFS -20. The axle
shall include a 3.74 inch drop and a 71.00 inch king pin intersection (KPI). The axle shall include a
conventional style hub with a standard knuckle.
FRONT AXLE WARRANTY
The front axle shall be warranted by Meritor for five (5) years with unlimited miles under the
general service application. Details of the Meritor warranty are provided on the PDF document
attached to this option.
FRONT WHEEL BEARING LUBRICATION
The front axle wheel bearings shall be lubricated with oil. The oil level can be visually checked via
clear inspection windows in the front axle hubs.
FRONT SHOCK ABSORBERS
Two (2) Bilstein inert, nitrogen gas filled shock absorbers shall be provided and installed as part
of the front suspension system. The shocks shall be a monotubular design and fabricated using a
special extrusion method, utilizing a single blank of steel without a welded seam, achieving an
extremely tight peak-to-valley tolerance and maintains consistent wall thickness. The
monotubular design shall provide superior strength while maximizing heat dissipation and shock
life.
The ride afforded through the use of a gas shock is more consistent and shall not deteriorate with
heat, the same way a conventional oil filled hydraulic shock would.
The Bilstein front shocks shall include a digressive working piston assembly allowing
independent tuning of the compression and rebound damping forces to provide optimum ride and
comfort without compromise. The working piston design shall feature fewer parts than most
conventional twin tube and “road sensing” shock designs and shall contribute to the durability
and long life of the Bilstein shock absorbers.
Proposals offering the use of conventional twin tube or “road sensing” designed shocks shall not
be considered.
FRONT SUSPENSION
The front suspension shall include a ten (10) leaf spring pack in which the longest leaf measures
54.00 inch long and 4.00 inches wide and shall include a military double wrapped front eye. Both
spring eyes shall have a case hardened threaded bushing installed with lubrication counter bore
and lubrication land off cross bore with grease fitting. The spring capacity shall be rated at 21,500
pounds.
STEERING COLUMN/ WHEEL
The cab shall include a Douglas Autotech steering column which shall include a seven (7)
position tilt, a 2.25 inch telescopic adjustment, and an 18.00 inch, two (2) spoke steering wheel
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 28
located at the driver’s position. The steering wheel shall be covered with black polyurethane foam
padding.
The steering column shall contain a horn button, self-canceling turn signal switch, four-way
hazard switch and headlamp dimmer switch.
ELECTRONIC POWER STEERING FLUID LEVEL INDICATOR
The power steering fluid shall be monitored electronically and shall send a signal to activate an
audible alarm and visual warning in the instrument panel when fluid level falls below normal.
POWER STEERING PUMP
The hydraulic power steering pump shall be a TRW PS and shall be gear driven from the
engine. The pump shall be a balanced, positive displacement, sliding vane type. The power
steering system shall include an oil to air passive cooler.
FRONT AXLE CRAMP ANGLE
The chassis shall have a front axle cramp angle of 48-degrees to the left and 44-degrees to the
right.
POWER STEERING GEAR
The power steering gear shall be a TRW model TAS 65 with an assist cylinder.
CHASSIS ALIGNMENT
The chassis frame rails shall be measured to insure the length is correct and cross checked to
make sure they run parallel and are square to each other. The front and rear axles shall be laser
aligned. The front tires and wheels shall be aligned and toe-in set on the front tires by the chassis
manufacturer.
REAR AXLE
The rear axle shall be a Meritor model RS-25-160 single drive axle. The axle shall include precision
forged, single reduction differential gearing, and shall have a fire service rated capacity of 27,000
pounds.
The axle shall be built of superior construction and quality components to provide the rugged
dependability needed to stand up to the fire industry’s demands. The axle shall include
rectangular shaped, hot-formed housing with a standard wall thickness of 0.63 of an inch for extra
strength and rigidity and a rigid differential case for high axle strength and reduced maintenance.
The axle shall have heavy-duty Hypoid gearing for longer life, greater strength and quieter
operation. Industry-standard wheel ends for compatibility with both disc and drum brakes, and
unitized oil seal technology to keep lubricant in and help prevent contaminant damage will be
used.
REAR AXLE DIFFERENTIAL LUBRICATION
The rear axle differential shall be lubricated with oil.
REAR AXLE WARRANTY
The rear axle shall be warranted by Meritor for five (5) years with unlimited miles under the
general service application. Details of the Meritor warranty are provided on the PDF document
attached to this option.
REAR WHEEL BEARING LUBRICATION
The rear axle wheel bearings shall be lubricated with oil.
VEHICLE TOP SPEED
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 29
The top speed of the vehicle shall be approximately 68 MPH +/-2 MPH at governed engine RPM.
REAR SUSPENSION
The single rear axle shall feature a Reyco 79KB vari-rate, self-leveling captive slipper type
conventional multi-leaf spring suspension, with 57.50 inch X 3.00 inch springs. One (1) adjustable
and one (1) fixed torque rod shall be provided.
The rear suspension capacity shall be rated from 21,000 to 31,500 pounds.
TIRE INTERMITTENT SERVICE RATING
The chassis shall be rated using Intermittent Service ratings provided to the emergency vehicle
market by the tire manufacturers as the basis for determining the maximum vehicle load and
speed.
FRONT TIRE
The front tires shall be Michelin 315/80R-22.5 20PR "L" tubeless radial XZUS 2 regional tread.
The front tire stamped load capacity shall be 20,000 pounds per axle with a nominal speed rating
of 65 miles per hour when properly inflated to 130 pounds per square inch.
The Michelin Intermittent Service Rating maximum load capacity shall be 21,400 pounds per axle
with a maximum speed of 65 miles per hour when properly inflated to 130 pounds per square inch.
The Michelin Intermittent Service Rating maximum speed capacity shall be 20,000 pounds per axle
with a speed rating of 75 miles per hour when properly inflated to 130 pounds per square inch.
The Michelin Intermittent Service Rating limits the operation of the emergency vehicle to no more
than fifty (50) miles of continuous operation under maximum recommended payload, or without
stopping for at least twenty (20) minutes. The emergency vehicle must reduce its spee d to no
more than 50 MPH after the first fifty (50) miles of travel.
REAR TIRE
The rear tires shall be Michelin 12R-22.5 16PR "H" tubeless radial XZE regional tread.
The rear tire stamped load capacity shall be 27,120 pounds per axle with a speed ratin g of 75
miles per hour when properly inflated to 120 pounds per square inch.
The Michelin Tire Intermittent Service Rating load capacity shall be 28,880 pounds per axle with a
speed rating of 75 miles per hour when properly inflated to 120 pounds per squ are inch. The
Michelin Intermittent Service Rating limits the operation of the emergency vehicle to one (1) hour
of loaded travel with a one (1) hour cool down prior to another loaded run.
REAR AXLE RATIO
The rear axle ratio shall be 5.38:1.
TIRE PRESSURE INDICATOR
There shall be electronic chrome LED valve caps shipped loose for installation by the OEM which
shall illuminate with a red LED when tire pressure drops 8psi provided. The valve caps are self -
calibrating and set to the pressure of the tire upon installation.
FRONT WHEEL
The front wheels shall be Alcoa hub piloted, 22.50 inch X 9.00 inch aluminum wheels featuring a
mirror polish on the outer face. The hub piloted mounting system shall provide easy installation
and shall include two-piece flange nuts.
REAR WHEEL
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 30
The outer rear wheels shall be Alcoa hub piloted, 22.50 inch X 8.25 inch aluminum wheels with a
mirror polished outer surface. The inner rear wheels shall be Alcoa hub piloted, 22.50 inch X 8.25
inch aluminum wheels with bright machine finish. The hub piloted mounting system shall provide
easy installation and shall include two-piece flange nuts.
BRAKE SYSTEM
A rapid build-up air brake system shall be provided. The air brakes shall include, at a minimum, a
two (2) air tank, three (3) reservoir system with a total of 4152 cubic inch of air capacity. A floor
mounted treadle valve shall be mounted inside the cab for graduated control of applying and
releasing the brakes. An inversion valve shall be installed to provide a controlled service brake
application during an unlikely event including primary air supply loss. All air reservoirs provided
on the chassis shall be labeled for identification.
The rear axle spring brakes shall automatically apply in any situation when the air pressure falls
below 25 PSI and shall include a mechanical means for releasing the spring brakes when
necessary. An audible alarm shall designate when the system air pressure is below 60 PSI.
A four (4) sensor, four (4) modulator Anti-lock Braking System (ABS) shall be installed on the front
and rear axles in order to prevent the brakes from locking or skidding while braking during hard
stops or on icy or wet surfaces. This in turn shall allow the driver to maintain steering control
under heavy braking and in most instances, shorten the braking distance. The electronic
monitoring system shall incorporate diagonal circuitry which shall monitor wheel speed during
braking through a sensor and tone ring on each wheel. A dash mounted ABS lamp shall be
provided to notify the driver of a system malfunction. The ABS system shall automatically
disengage the auxiliary braking system device when required. The speedometer screen shall be
capable of reporting all active defaults using PID/SID and FMI standards.
FRONT BRAKES
The front brakes shall be Meritor 16.50 inch x 6.00 inch S-cam drum type.
REAR BRAKES
The rear brakes shall be Meritor 16.50 inch X 8.63 inch S-cam drum type. The brakes shall feature
a cast iron shoe.
PARK BRAKE
Upon application of the push-pull valve in the cab, the rear brakes will engage via mechanical
spring force. This is accomplished by dual chamber rear brakes, satisfying the FMVSS parking
brake requirements.
PARK BRAKE CONTROL
A Meritor-Wabco manual hand control push-pull style valve shall operate the parking brake.
The parking brake actuation valve shall be mounted to the left side of the engine tunnel integrated
into the transmission shift pod console within easy access of the driver.
FRONT BRAKE SLACK ADJUSTERS
The front brakes shall include Meritor automatic slack adjusters installed on the chassis which
features a simple, durable design offering reduced weight. The automatic slack adjusters shall
feature a manual adjusting nut which cannot inadvertently be backed off and threaded grease
fittings for easy serviceability.
REAR BRAKE SLACK ADJUSTERS
The rear brakes shall include Meritor automatic slack adjusters installed on the axle which
features a simple, durable design offering reduced weight. The automatic slack adjusters shall
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 31
feature a manual adjusting nut which cannot inadvertently be backed off and threaded grease
fittings for easy serviceability.
AIR DRYER
The brake system shall include a Wabco System Saver 1200 air dryer with an integral 100 watt
heater with a Metri-Pack sealed connector. The air dryer incorporates an internal turbo cutoff
valve that closes the path between the air compressor and air dryer purge valve during the
compressor "unload" cycle. The turbo cutoff valve allows purging of moistur e and contaminants
without the loss of turbo boost pressure. The air dryer shall be located on the right hand frame
rail forward of the front wheel behind the right hand cab step.
FRONT BRAKE CHAMBERS
The front brakes shall be provided with MGM type 30 brake chambers.
REAR BRAKE CHAMBERS
The rear axle shall include TSE 30/36 brake chambers which shall convert the energy of
compressed air into mechanical force and motion. This shall actuate the brake camshaft, which in
turn shall operate the foundational brake mechanism forcing the brake shoes against the brake
drum. The TSE Type 36 brake chamber has a 36.00 square inch effective area.
AIR COMPRESSOR
The air compressor provided for the engine shall be a Wabco® SS318 single cylinder pass-through
drive type compressor which shall be capable of producing 18.7 CFM at 1200 engine RPMs. The
air compressor shall feature a higher delivery efficiency translating to more air delivery per
horsepower absorbed. The compressor shall include an aluminum cylinder head which shall
improve cooling, reduce weight and decrease carbon formation. Superior piston and bore
finishing technology shall reduce oil consumption and significantly increasing the system
component life.
AIR GOVERNOR
An air governor shall be provided to control the cut-in and cut-out pressures of the engine
mounted air compressor. The governor shall be calibrated to meet FMVSS requirements. The air
governor shall be located on the air dryer bracket.
MOISTURE EJECTORS
Manual pet-cock type drain valves shall be installed on all reservoirs of the air supply system.
AIR SUPPLY LINES
The air system on the chassis shall be plumbed with color coded reinforced nylon tubing air
lines. The primary (rear) brake line shall be green, the secondary (front) brake line red, the
parking brake line orange and the auxiliary (outlet) will be blue.
Push to connect type fittings shall be used on the nylon tubing. All drop hoses shall include fiber
reinforced neoprene covered hoses.
WHEELBASE
The chassis wheelbase shall be 187.00 inches.
REAR OVERHANG
The chassis rear overhang shall be 52.00 inches.
FRAME
The frame shall consist of double rails running parallel to each other with cross members forming
a ladder style frame. The frame rails shall be formed in the shape of a "C" channel, with the outer
rail measuring 10.25 inches high X 3.50 inches deep upper and lower flanges X 0.38 inches thick
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 32
with an inner channel of 9.44 inches high X 3.13 inches deep and 0.38 inches thick. Each rail shall
be constructed of 110,000 psi minimum yield high strength low alloy steel. Each double rail
section shall be rated by a Resistance Bending Moment (RBM) minimum of 3,213,100 inch pounds
and have a minimum section modulus of 29.21 cubic inches. The frame shall measure 35.00
inches in width.
Proposals calculating the frame strength using the “box method” shall not be considered.
Proposals including heat treated rails shall not be considered. Heat treating frame rails produces
rails that are not uniform in their mechanical properties throughout the length of the rail. Rails
made of high strength, low alloy steel are already at the required yield strength prior to forming
the rail.
A minimum of seven (7) fully gusseted 0.25 inch thick cross members shall be installed. The
inclusion of the body mounting, or bumper mounting shall not be considered as a cross member.
The cross members shall be attached using zinc coated grade 8 fasteners. The bolt heads shall be
flanged type, held in place by distorted thread flanged lock nuts. Each cross member shall be
mounted to the frame rails utilizing a minimum of 0.25 inch thick gusset reinforcement plates at all
corners balancing the area of force throughout the entire frame.
.
Any proposals not including additional reinforcement for each cross member shall not be
considered.
All relief areas shall be cut in with a minimum 2.00 inch radius at intersection points with the
edges ground to a smooth finish to prevent a stress concentration point.
FRAME PAINT
The frame shall be powder coated black prior to any attachment of components.
All powder coatings, primers and paint shall be compatible with all metals, pretreatments and
primers used. The cross hatch adhesion test per ASTM D3359 shall not have a fail of more than
ten (10) squares. The pencil hardness test per ASTM D3363 shall have a final post-curved pencil
hardness of H-2H. The direct impact resistance test per ASTM D2794 shall have an impact
resistance of 120.00 inches per pound at 2 mils.
Any proposals offering painted frame with variations from the above process shall not be
accepted. The film thickness of vendor supplied parts shall also be sufficient to meet the
performance standards as stated above.
FRAME ASSEMBLY STRUCTURAL
Purchaser shall receive a Frame Assembly Structural Five (5) Years limited warranty in
accordance with, and subject to, warranty certificate RFW0301. The warranty certificate is
incorporated by reference into this proposal, and included with this proposal or available upon
request.
FRAME RAIL CORROSION
Purchaser shall receive a Frame Rail Corrosion (Powder Coat) Three (3) Years or 48,000 Miles
limited warranty in accordance with, and subject to, warranty certificate RFW0311. The warranty
certificate is incorporated by reference into this proposal, and included with this proposal or
available upon request.
FRAME COMPONENTS CORROSION
Purchaser shall receive a Frame Components Corrosion (Powder Coat) One (1) Year or 18,000
Miles limited warranty in accordance with, and subject to, warranty certificate RFW0313. The
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 33
warranty certificate is incorporated by reference into this proposal, and included with this
proposal or available upon request.
FRONT BUMPER
A one piece, two (2) rib wrap-around style, polished stainless steel front bumper shall be
provided. The material shall be 10 gauge 304 stainless steel, 12.00 inches high and 99.00 inches
wide.
FRONT BUMPER EXTENSION LENGTH
The front bumper shall be extended approximately 6.00 inches ahead of the cab.
AIR HORN
The front bumper shall include two (2) Hadley brand E-Tone air horns which shall measure 21.00
inches long with a 6.00 inch round flare. The air horns shall be trumpet style with a chrome finish
on the exterior and a painted finish deep inside the trumpet.
AIR HORN LOCATION
The air horns shall be recess mounted in the front bumper face, one (1) on the right side of the
bumper in the inboard position relative to the right hand frame rail and one (1) on the left side of
the bumper in the inboard position relative to the left hand frame rail.
AIR HORN RESERVOIR
One (1) air reservoir, with a 1200 cubic inch capacity, shall be installed on the chassis to act as a
supply tank for operating air horns. The reservoir shall be isolated with a 90 PSI pressure
protection valve on the reservoir supply side to prevent depletion of the air to the air brake
system.
ELECTRONIC SIREN SPEAKER
There shall be one (1) Cast Products Inc. model SA4301, 100 watt speaker provided. The speaker
shall measure 6.20 inches tall X 7.36 inches wide X 3.06 inches deep. The speaker shall include a
flat mounting flange which shall be polished aluminum.
ELECTRONIC SIREN SPEAKER LOCATION
The electronic siren speaker shall be located on the front bumper face on the right side outboard
of the frame rail in the far outboard position.
FRONT BUMPER TOW HOOKS
Two (2) heavy duty tow hooks, painted to match the frame components, shall be installed behind
the front bumper in the forward position, bolted directly to the side of each chassis frame rail with
grade 8 bolts.
CAB TILT SYSTEM
The entire cab shall be capable of tilting approximately 45-degrees to allow for easy maintenance
of the engine and transmission. The cab tilt pump assembly shall be located on the right side of
the chassis above the battery box.
The electric-over-hydraulic lift system shall include an ignition interlock and red cab lock down
indicator lamp on the tilt control which shall illuminate when holding the “Down” button to
indicate safe road operation.
It shall be necessary to activate the master battery switch and set the parking brake in order to tilt
the cab. As a third precaution the ignition switch must be turned off to complete the cab tilt
interlock safety circuit.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 34
Two (2) spring-loaded hydraulic hold down hooks located outboard of the frame shall be installed
to hold the cab securely to the frame. Once the hold-down hooks are set in place, it shall take the
application of pressure from the hydraulic cab tilt lift pump to release the hooks.
Two (2) cab tilt cylinders shall be provided with velocity fuses in each cylinder port. The cab tilt
pivots shall be 1.90 inch ball and be anchored to frame brackets with 1.25 inch diameter studs.
A steel safety channel assembly, painted safety yellow shall be installed on the right side cab lift
cylinder to prevent accidental cab lowering. The safety channel assembly shall fall over the lift
cylinder when the cab is in the fully tilted position. A cable release system shall also be provided
to retract the safety channel assembly from the lift cylinder to allow the lowering of the cab.
CAB TILT CONTROL RECEPTACLE
The cab tilt control cable shall include a receptacle which shall be temporarily located on the rig ht
hand chassis rail rear of the cab to provide a place to plug in the cab tilt remote control
pendant. The tilt pump shall include 8.00 feet of cable with a six (6) pin Deutsch receptacle with a
cap.
The remote control pendant shall include 20.00 feet of cable with a mating Deutsch connector. The
remote control pendant shall be shipped loose with the chassis.
CAB TILT LOCK DOWN INDICATOR
The cab dash shall include a message located within the dual air pressure gauge which shall alert
the driver when the cab is unlocked and ajar. The alert message shall cease to be displayed when
the cab is in the fully lowered position and the hold down hooks are secured and locked to the
cab mounts.
In addition to the alert message an audible alarm shall sound when the cab is unlocked and ajar
with the parking brake released.
CAB WINDSHIELD
The cab windshield shall have a surface area of 2825.00 square inches and be of a two (2) piece
wraparound design for maximum visibility.
The glass utilized for the windshield shall include standard automotive tint. The left and right
windshield shall be fully interchangeable thereby minimizing stocking and replacement costs.
Each windshield shall be installed using black self locking window rubber.
GLASS FRONT DOOR
The front cab doors shall include a window which is 27.00 inches in width X 26.00 inches in
height. These windows shall have the capability to roll down completely into the door
housing. This shall be accomplished manually utilizing a crank style handle on the inside of the
door. A reinforced window regulator assembly shall be provided for severe duty use.
There shall be an irregular shaped fixed window which shall measure 2.50 inches wide at the top,
8.00 inches wide at the bottom X 26.00 inches in height, more commonly known as “cozy glass”
ahead of the front door roll down windows.
The windows shall be mounted within the frame of the front doors trimmed with a black anodized
ring on the exterior.
GLASS TINT FRONT DOOR
The windows located in the left and right front doors shall have a standard green automotive tint
which shall allow seventy-five percent (75%) light transmittance.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 35
GLASS REAR DOOR RH
The rear right hand side door shall include a window which is 27.00 inches in width X 26.00 inches
in height. This window shall roll up and down manually utilizing a crank style handle on the inside
of the door. A reinforced window regulator assembly shall be provided for severe duty use.
GLASS TINT REAR DOOR RIGHT HAND
The window located in the right hand side rear door shall include a standard green automotive tint
which shall allow seventy-five percent (75%) light transmittance.
GLASS REAR DOOR LH
The rear left hand side door shall include a window which is 27.00 inches in width X 26.00 inches
in height. This window shall roll up and down manually utilizing a crank style handle on the inside
of the door. A reinforced window regulator assembly shall be provided for severe duty use.
GLASS TINT REAR DOOR LEFT HAND
The window located in the left hand side rear door shall include a standard green automotive tint
which shall allow seventy-five percent (75%) light transmittance.
GLASS SIDE MID RH
The cab shall include a window on the right side behind the front and ahead of the crew door
which shall measure 16.00 inches wide X 26.00 inches high. This window shall be fixed within this
space and shall be rectangular in shape. The window shall be mounted using self locking window
rubber. The glass utilized for this window shall include a green automotive tint unless otherwise
noted.
GLASS TINT SIDE MID RIGHT HAND
The window located on the right hand side of the cab between the front and rear doors shall
include a standard green automotive tint which shall allow seventy-five percent (75%) light
transmittance.
GLASS SIDE MID LH
The cab shall include a window on the left side behind the front door and ahead of the crew door
and above the wheel well which shall measure 16.00 inches wide X 26.00 inches high. This
window shall be fixed within this space and shall be rectangular in shape. The window shall be
mounted using self locking window rubber. The glass utilized for this window shall include a
green automotive tint unless otherwise noted.
GLASS TINT SIDE MID LEFT HAND
The window located on the left hand side of the cab between the front and rear doors shall include
a standard green automotive tint which shall allow seventy-five percent (75%) light transmittance.
CLIMATE CONTROL
The cab shall include a 57,500 BTU @ 425 CFM front overhead heater/defroster which shall be
provided and installed above the windshield between the sun visors.
The cab shall also include a combination heater air-conditioning unit mounted on the engine
tunnel. This unit shall offer eight (8) adjustable louvers, four (4) forward facing and four (4)
rearward facing, a temperature control valve and two (2) blowers offering three (3) speeds which
shall be capable of circulating 550 cubic feet of air per minute. The unit shall be rated for 42,500
BTU/Hr of cooling and 36,000 BTU/Hr of heating.
All defrost/heating systems shall be plumbed with one (1) seasonal shut-off valve at the front
corner on the right side of the cab.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 36
The air conditioner lines shall be a mixture of custom bend zinc coated steel fittings and Aeroqui p
flexible hose with Aeroquip EZ clip fittings.
CLIMATE CONTROL DRAIN
The climate control system shall include a gravity drain for water management. The gravity drain
shall remove condensation from the air conditioning system without additional mechanic al
assistance.
CLIMATE CONTROL ACTIVATION
The heating and defrosting controls shall be located on the front overhead climate control
unit. There shall be additional heating and air conditioning controls located on the engine tunnel
mounted climate control unit.
A/C CONDENSER LOCATION
A roof mounted A/C condenser shall be installed centered on the cab forward of the raised roof
against the slope rise.
A/C COMPRESSOR
The air-conditioning compressor shall be a belt driven, engine mounted, open type compressor
that shall be capable of producing a minimum of 32,000 BTU at 1500 engine RPMs. The
compressor shall utilize R-134A refrigerant and PAG oil.
UNDER CAB INSULATION
The underside of the cab tunnel surrounding the engine shall be lined with multi-layer insulation,
engineered for application inside diesel engine compartments.
The insulation shall act as a noise barrier, absorbing noise thus keeping the decibel level in the
cab well within NFPA recommendations. As an additional benefit, the insulation shall assist in
sustaining the desired temperature within the cab interior.
The engine tunnel insulation shall measure approximately 0.30 inch thick including a multi -layer
foil faced glass cloth and polyester fiber layer. The foil surface acts as protection against heat,
moisture and other contaminants. The insulation shall meet or exceed FMVSS 302 flammability
test.
The insulation shall be cut precisely to fit each section and sealed for additional heat and sound
deflection. The insulation shall be held in place by acrylic pressure sensitive adhesive.
INTERIOR TRIM FLOOR
The floor of the cab shall be covered with a multi-layer mat consisting of 0.25 inch thick sound
absorbing closed cell foam with a 0.06 inch thick non-slip vinyl surface with a pebble grain
finish. The covering shall be held in place by a pressure sensitive adhesive and aluminum trim
molding. All exposed seams shall be sealed with silicone caulk matching the color of the floor
mat to reduce the chance of moisture and debris retention.
INTERIOR TRIM
The cab interior shall include trim on the front ceiling, rear crew ceiling, and the cab walls. It shall
be easily removable to assist in maintenance. The trim shall be constructed of insulated vinyl
over a hard board backing.
REAR WALL INTERIOR TRIM
The rear wall of the cab shall be trimmed with vinyl.
HEADER TRIM
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 37
The cab interior shall feature header trim over the driver and officer dash constructed of 5052 -H32
Marine Grade, 0.13 inch thick aluminum.
TRIM CENTER DASH
The main center dash area shall be constructed of 5052-H32 Marine Grade, 0.13 inch thick
aluminum plate. There shall be four (4) holes located on the top of the dash near each outer edge
of the electrical access cover for ventilation.
TRIM LH DASH
The left hand dash shall be constructed of 5052-H32 Marine Grade, 0.13 inch thick aluminum plate
for a perfect fit around the instrument panel. For increased occupant protection the extreme duty
left hand dash utilizes patent pending break away technology to reduce rigidity in the event of a
frontal crash. The left hand dash shall offer lower vertical surface area to the left and right of the
steering column to accommodate control panels.
TRIM RH DASH
The right hand dash shall be constructed of 5052-H32 Marine Grade, 0.13 of an inch thick
aluminum plate and shall include a glove compartment with a hinged door and a Mobile Data
Terminal (MDT) provision. The glove compartment size will measure 14.00 inches wide X 6.38
inches high X 5.88 inches deep. The MDT provision shall be provided above the glove
compartment.
ENGINE TUNNEL TRIM
The cab engine tunnel shall be covered with a multi-layer mat consisting of 0.25 inch closed cell
foam with a 0.06 inch thick non-slip vinyl surface with a pebble grain finish. The mat shall be held
in place by pressure sensitive adhesive. The engine tunnel mat shall be trimmed with anodized
aluminum stair nosing trim for an aesthetically pleasing appearance.
STEP TRIM
Each cab entry door shall include a three step entry. The first step closest to the ground shall be
constructed of polished 5032 H32 aluminum Grip Strut® grating with angled outer corners. The
step shall feature a splash guard to reduce water and debris from splashing in to the step. The
splash guard shall have an opening on the outer edge to allow debris and water to flow through
rather than becoming trapped within the stepping surface. The lower step shall be mounted to a
frame which is integral with the construction of the cab for rigidity and strength. The middle step
shall be integral with the cab construction and shall be trimmed with a Flex -Tred® adhesive grit
surface material.
INTERIOR DOOR TRIM
The interior trim on the doors of the cab shall consist of an aluminum panel constructed of Marine
Grade 5052-H32 0.13 of an inch thick aluminum plate. The door panels shall include a painted
finish.
CAB DOOR TRIM REFLECTIVE
In accordance with the current standards of NFPA, the body builder shall provide 96.00 square
inches of reflective material on the interior of each cab door.
INTERIOR GRAB HANDLE "A" PILLAR
There shall be two (2) rubber covered 11.00 inch grab handles installed inside the cab, one on
each “A” post at the left and right door openings. The left handle shall be located 7.88 inches
above the bottom of the door window opening and the right handle shall be located 2.88 inches
above the bottom of the door window opening. The handles shall assist personnel in entering and
exiting the cab.
INTERIOR GRAB HANDLE FRONT DOOR
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 38
Each front door shall include one (1) ergonomically contoured 9.00 inch cast aluminum handle
mounted horizontally on the interior door panels. The handles shall feature a textured black
powder coat finish to assist personnel entering and exiting the cab.
INTERIOR GRAB HANDLE REAR DOOR
A black powder coated cast aluminum assist handle shall be provided on the inside of each rear
crew door. A 30.00 inch long handle shall extend horizontally the width of the window just above
the window sill. The handle shall assist personnel in exiting and entering the cab.
INTERIOR SOFT TRIM COLOR
The cab interior soft trim surfaces shall be gray in color.
INTERIOR TRIM SUNVISOR
The header shall include two (2) sun visors, one each side forward of the driver and officer s eating
positions above the windshield. Each sun visor shall be constructed of Masonite and covered
with padded vinyl trim.
INTERIOR FLOOR MAT COLOR
The cab interior floor mat shall be gray in color.
CAB PAINT INTERIOR DOOR TRIM
The inner door panel surfaces shall be painted with multi-tone silver gray texture finish.
HEADER TRIM INTERIOR PAINT
The metal surfaces in the header area shall be coated with multi-tone silver gray texture finish.
TRIM CENTER DASH INTERIOR PAINT
The entire center dash shall be coated with multi-tone silver gray texture finish. Any accessory
pods attached to the dash shall also be painted this color.
TRIM LH DASH INTERIOR PAINT
The left hand dash shall be painted with a multi-tone silver gray texture finish.
TRIM RIGHT HAND DASH INTERIOR PAINT
The right hand dash shall be painted with multi-tone silver gray texture finish.
DASH PANEL GROUP
The main center dash area shall include three (3) removable panels located one (1) to the right of
the driver position, one (1) in the center of the dash and one (1) to the left of the officer position.
The center panel shall be within comfortable reach of both the driver and officer.
SWITCHES CENTER PANEL
The center dash panel shall include twelve (12) rocker switch positons in a single row across the
top of the panel.
A rocker switch with a blank legend installed directly above shall be provided for any position
without a switch and legend designated by a specific option. The non-specified switches shall be
two-position, black switches with a green indicator light. Each blank switch legend can be custom
engraved by the body manufacturer. All switch legends shall have backlighting provided.
SWITCHES LEFT PANEL
The left dash panel shall include eight (8) switches. There shall be six (6) switches across the top
of the panel and two (2) staggered on the left hand portion of the panel. Five (5) of the top row of
switches shall be rocker type and the left one (1) shall be the headlight switch. The remaining
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 39
switches shall consist of one (1) windshield wiper/washer control switch and one (1) instrument
lamp dimmer switch.
A rocker switch with a blank legend installed directly above shall be provided for any position not
designated by a specific option. The non-designated switches shall be two-position, black
switches with a green indicator light. Each blank switch legend can be custom engraved by the
body manufacturer. All switch legends shall have backlighting provided.
SWITCHES RIGHT PANEL
The right dash panel shall include no rocker switches or legends.
SEAT BELT WARNING
A Weldon seat belt warning system, integrated with the Vehicle Data Recorder system, shall be
installed for each seat within the cab. The system shall activate a digital seat position indicator
with a seat position legend and integrated audible alarm in the switch panel.
The warning system shall activate when any seat is occupied with a minimum of 60 pounds and
the corresponding seat belt remains unfastened. The warning system shall also ac tivate when any
seat is occupied and the corresponding seat belt was fastened in an incorrect sequence. Once
activated, the visual indicators and applicable audible alarm shall remain active until all occupied
seats have the seat belts fastened.
SEAT MATERIAL
The Bostrom Firefighter seats shall include a covering of extra high strength, wear resistant fabric
made of durable low seam Durawear Plus™ ballistic polyester. A PVC coating shall be bonded to
the back side of the material to help protect the seats from UV rays and from being saturated or
contaminated by fluids. Durawear Plus™ meets or exceeds specification of the common trade
name Imperial 1800. The material meets FMVSS 302 flammability requirements.
If applicable, Theatre style seats located in the cab shall be high strength, wear resistant fabric
made of durable ballistic polyester. A PVC coating shall be bonded to the back side of the
material to help protect the seats from UV rays and from being saturated or contaminated by
fluids. Common trade names for this material are Imperial 1200 and Durawear.
SEAT COLOR
All seats supplied with the chassis shall be gray in color. All seats shall include red seat belts.
SEAT BACK LOGO
The seat back shall include the “KME” logo. The logo shall be centered on the standard headrest
of the seat back and on the left side of a split headrest.
SEAT DRIVER
The driver's seat shall be an H.O. Bostrom 400 Series Firefighter model seat. The seat shall
feature two-way manual fore and aft adjustment with 5.00 inches of travel. The seat shall also
feature integral springs to isolate shock.
The seat shall feature an all belts to seat (ABTS) safety restraint system. The ABTS feature shall
include a three-point shoulder harness with the lap belt, automatic retractor and buckle as an
integral part of the seat assembly. The buckle portion of the seat belt shall be mounted on a semi-
rigid stalk extending from the seat base within easy reach of the occupant.
The minimum vertical dimension from the seat H-point to the ceiling for this belted seating
position shall be 35.00 inches.
This model of seat shall have successfully completed the static load tests set forth by FMVSS 207,
209, and 210 in effect at the time of manufacture. This testing shall include a simultaneous
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 40
forward load of 3000 pounds each on the lap and shoulder belts and twenty (20) times the weight
through the center of gravity.
The materials used in construction of the seat shall also have successfully completed testing with
regard to the flammability of materials used in the occupant compartments of motor vehicles as
outlined in FMVSS 302, of which dictates the allowable burning rate of materials in the occupant
compartments of motor vehicles.
SEAT BACK DRIVER
The driver’s seat shall include a standard seat back incorporating the all belts to seat feature
(ABTS). The seat back shall feature a contoured head rest.
SEAT MOUNTING DRIVER
The driver’s seat shall be installed in an ergonomic position in relation to the cab dash.
SEAT OFFICER
The officer's seat shall be a H.O. Bostrom 300 Series Firefighter series. The seat shall feature a
tapered and padded seat, and cushion. The seat shall be a non-adjustable type seat.
The seat shall feature an all belts to seat (ABTS) style of safety restraint. The ABTS feature shall
include a three-point shoulder harness with the lap belt and automatic retractor as an integral part
of the seat assembly. The buckle portion of the seat belt shall extend from the seat base towards
the driver position within easy reach of the occupant.
The minimum vertical dimension from the seat H-point to the ceiling for this belted seating
position shall be 35.00 inches.
This model of seat shall have successfully completed the static load tests by FMVSS
207/210. This testing shall include a simultaneous forward load of 3000 pounds each on the lap
and shoulder belts and twenty (20) times the weight through the center of gravity. This model of
seat installed in the cab model, as specified, shall have successfully completed the dynamic sled
testing using FMVSS 208 as a guide with the following accommodations. In order to reflect the
larger size outfitted firefighters, the test dummy used shall be a 95th percentile hybrid III male
weighing 225 pounds rather than the 50th percentile male dummy weighing 165 pounds as
referenced in FMVSS 208. The model of seats shall also have successfully completed the
flammability of materials used in the occupant compartments of motor vehicles as outlined in
FMVSS 302, of which decides the burning rate of materials in the occupant compartments of
motor vehicles.
SEAT BACK OFFICER
The officer’s seat shall feature a SecureAll™ SCBA locking system which shall be one bracket
model and store most U.S. and International SCBA brands and sizes while in transit or for storage
within the seat back. The bracket shall be easily adjustable for all SCBA brands and cylinder
diameters. All adjustment points shall utilize similar hardware and adjustments shall be made with
one tool.
The bracket shall be adjustable to compensate for different cylinder lengths without the use of
tools. The adjustment shall be made by raising a lever and moving the top clamp vertically.
The bracket system shall be free of straps and clamps that may interfere with auxiliary equipment
on SCBA units. The center guide fork shall keep the SCBA tank in place for a safe and
comfortable fit in the seat back cavity. The SCBA unit simply needs to be pushed against the
pivot arm to engage the patented auto- locking system. Once the lock is engaged, the top clamp
shall surround the top of the SCBA tank for a secure fit in all directions.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 41
The SecureAll™ shall include a release handle which shall be integrated into the seat cushion for
quick and easy release. This shall eliminate the need for straps or pull cords to interfere with
other SCBA equipment.
The seat back shall include a removable padded cover which shall be provided over the SCBA
cavity.
SEAT MOUNTING OFFICER
The officer’s seat shall be installed in an ergonomic position in relation to the cab dash.
SEAT BELT ORIENTATION CREW
The crew position seat belts shall follow the standard orientation which extends from the
outboard shoulder extending to the inboard hip.
SEAT FORWARD FACING CENTER LOCATION
The crew area shall include two (2) forward facing center crew seats with both located at the
center of the rear wall.
SEAT CREW FORWARD FACING CENTER
The crew area shall include a seat in the forward facing center position which shall be a H.O.
Bostrom 300 Series Firefighter model seat. The seat shall feature a tapered and padded seat, and
cushion. The seat and cushion shall be hinged and compact in design for additional room and
shall remain in the stored position until occupied.
The seat shall feature an all belts to seat (ABTS) style of safety restraint. The ABTS feature shall
include a three-point shoulder harness with the lap belt and automatic retractor as an integral part
of the seat assembly. The buckle portion of the seat belt shall extend from the seat base towards
the driver position within easy reach of the occupant.
The minimum vertical dimension from the seat H-point to the ceiling for each belted seating
position shall be 35.00 inches.
This model of seat shall have successfully completed the static load tests by FMVSS
207/210. This testing shall include a simultaneous forward load of 3000 pounds each on the lap
and shoulder belts and twenty (20) times the weight through the center of gravity. This model of
seat installed in the cab model, as specified, shall have successfully completed the dynamic sled
testing using FMVSS 208 as a guide with the following accommodations. In order to reflect the
larger size outfitted firefighters, the test dummy used shall be a 95th percentile hybrid I II male
weighing 225 pounds rather than the 50th percentile male dummy weighing 165 pounds as
referenced in FMVSS 208. The model of seats shall also have successfully completed the
flammability of materials used in the occupant compartments of motor vehic les as outlined in
FMVSS 302, of which decides the burning rate of materials in the occupant compartments of
motor vehicles.
SEAT BACK FORWARD FACING CENTER
The forward facing center seat shall feature a SecureAll™ self contained breathing apparatus
(SCBA) locking system which shall be one bracket model and store most U.S. and International
SCBA brands and sizes while in transit or for storage within the seat back. The bracket shall be
easily adjustable for all SCBA brands and cylinder diameters. All adjustment points shall utilize
similar hardware and adjustments shall be made with one tool.
The bracket shall be adjustable to compensate for different cylinder lengths without the use of
tools. The adjustment shall be made by raising a lever and moving the top clamp vertically.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 42
The bracket system shall be free of straps and clamps that may interfere with auxiliary equipment
on SCBA units. The center guide fork shall keep the SCBA tank in place for a safe and
comfortable fit in the seat back cavity. The SCBA unit simply needs to be pushed against the
pivot arm to engage the patented auto- locking system. Once the lock is engaged, the top clamp
shall surround the top of the SCBA tank for a secure fit in all directions.
The SecureAll™ shall include a release handle which shall be integrated into the seat cushion for
quick and easy release. This shall eliminate the need for straps or pull cords to interfere with
other SCBA equipment.
The seat back shall include a removable padded cover which shall be provided over the SCBA
cavity.
SEAT FRAME FORWARD FACING
The forward facing seating position shall include two (2) channel type risers for each seat. The
risers shall be constructed of 0.19 inch thick steel with 1.50 inch flanges. The risers shall be
painted black.
SEAT MOUNTING FORWARD FACING CENTER
The forward facing center seats shall be installed facing the front of the cab.
WINDSHIELD WIPER SYSTEM
The cab shall include a triple arm linkage wiper system which shall clear the wind shield of water,
ice and debris. There shall be two (2) windshield wipers; each shall be affixed to a radial arm. The
wiper motor shall be activated by an intermittent wiper control located within easy reach of the
driver’s position.
ELECTRONIC WINDSHIELD FLUID LEVEL INDICATOR
The windshield washer fluid level shall be monitored electronically. When the washer fluid level
becomes low the yellow “Check Message Center” indicator light on the instrument panel shall
illuminate and the message center in the dual air pressure gauge shall display a “Check Washer
Fluid Level” message.
CAB DOOR HARDWARE
The cab entry doors shall be equipped with exterior pull handles, suitable for use while wearing
firefighter gloves. The handles shall be made of a fiber reinforced plastic composite with a black
matt finish.
The interior exit door handles shall be flush paddle type with a black finish, which are
incorporated into the upper door panel.
All cab entry doors shall include locks which are keyed alike. The door locks shall be designed to
prevent accidental lockout.
DOOR LOCKS
Each cab entry door shall include a manually operated door lock. Each door lock may be actuated
from the inside of the cab by means of a red knob located on the paddle handle of the respective
door or by using a TriMark key from the exterior. The door locks are designed to prevent
accidental lock out.
GRAB HANDLES
The cab shall include one (1) 18.00 inch knurled, anti-slip, one-piece exterior assist handle behind
each cab door. The grab handle shall be made of SAE 304 stainless steel and be 1.25 inch
diameter to enable non-slip assistance with a gloved hand.
REARVIEW MIRRORS
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 43
Retrac West Coast style single vision mirror heads model 1171 shall be provided and installed on
each of the front cab doors. The mirrors shall be mounted to the cab doors with tubular stainless
steel swing away arms and the mirror heads shall be center mounted on the arms to provide rigid
mounting to reduce vibration.
The flat mirrors shall measure 7.00 inches wide x 16.00 inches high. A separate lower 8.00 inch
round manually adjustable convex mirror model 980-4 shall be provided below the flat mirror for a
wider field of vision. The mirror glass shall be held in a plastic housing with a stainless steel
back. The mirrors shall be manufactured with the finest quality non-glare glass.
The flat mirrors shall be remotely adjustable vertically and horizontally via four way actuation
switches. The control switches shall be mounted in the cab with in easy reach of the driver.
CAB FENDER
Full width wheel well liners shall be installed on the extruded cab to limit road splash and enable
easier cleaning. Each two-piece liner shall consist of an inner liner 16.00 inches wide made of
vacuum formed ABS composite and an outer fenderette 3.50 inches wide made of rubber.
CAB EXTERIOR FRONT SIDE EMBLEMS
The cab shall include one (1) Spartan emblem installed on the front air intake grille.
IGNITION
A master battery system with a keyless start ignition system shall be provided. Each system shall
be controlled by a one-quarter turn Cole Hersee switch, both of which shall be mounted to the left
of the steering wheel on the dash. A chrome push type starter button shall be provided adjacent
to the master battery and ignition switches.
Each switch shall illuminate a green LED indicator light on the dash when the respective switch is
placed in the “ON” position.
The starter button shall only operate when both the master battery and ignition switches are in the
“ON” position.
BATTERY
The single start electrical system shall include three (3) Harris BCI 31 925 CCA batteries with a 210
minute reserve capacity and 4/0 welding type dual path starter cables per SAE J541.
BATTERY TRAY
The batteries shall be installed on a steel battery tray located on the left side of the chassis,
securely bolted to the frame rails. The battery tray shall be coated with the same material as the
frame.
The battery tray shall include drain holes in the bottom for sufficient drainage of water. A durable,
non-conducting, interlocking mat made by Dri-Dek shall be installed in the bottom of the tray to
allow for air flow and help prevent moisture build up. The batteries shall be held in place by non -
conducting phenolic resin hold down boards.
BATTERY BOX COVER
The battery box shall include a steel cover which protects the top of the batteries on the left hand
side of the vehicle. The cover shall include flush latches which shall keep the cover secure as
well as a black powder coated handle for convenience when opening.
BATTERY CABLE
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 44
The starting system shall include cables which shall be protected by 275 degree F. minimum high
temperature flame retardant loom, sealed at the ends with heat shrink and sealant.
The battery terminals shall not be utilized for auxiliary connections. The only acceptable auxiliary
connections shall be for the cross over link from the left bank to the right bank, power for jumper
studs and starter cables. All other auxiliary connections will use remote studs mounted in the
battery box area. There shall be four (4) remote studs labeled as Common Power, Common
Ground, Clean Power, and Clean Ground.
BATTERY JUMPER STUD
The starting system shall include battery jumper studs. These studs shall be located on the rear
face of the left hand battery tray. The studs shall allow the vehicle to be jump started, charged, or
the cab to be raised in an emergency in the event of battery failure.
ALTERNATOR
The charging system shall include a 270 amp Leece Neville 12 volt alternator. The alternator shall
include a self-excited integral regulator.
STARTER MOTOR
The single start electrical system shall include a Delco brand starter motor.
BATTERY CONDITIONER
A Kussmaul Auto Charge 40 LPC battery conditioner shall be supplied. The battery conditioner
shall provide a 40 amp output for the chassis batteries and a 15 amp output circuit for accessory
loads. The battery conditioner shall be mounted in the cab in the LH rear facing outer seating
position.
BATTERY CONDITIONER DISPLAY
A Kussmaul battery conditioner display shall be supplied. The battery conditioner display shall be
mounted in the cab, viewable through the cab mid side window behind the left front door.
ELECTRICAL INLET LOCATION
An electrical inlet shall be installed on the left hand side of cab over the wheel well.
ELECTRICAL INLET
A Kussmaul 20 amp super auto-eject electrical receptacle shall be supplied. It shall automatically
eject the plug when the starter button is depressed.
A single item or an addition of multiple items must not exceed the rating of the electric inlet that
it’s connected to.
Amp Draw Reference List:
Kussmaul 40 LPC Charger - 5 Amps
Kussmaul 40/20 Charger - 8.5 Amps
Kussmaul 80 LPC Charger - 13 Amps
Kussmaul EV-40 - 6.2 Amps
Blue Sea P12 7532 - 7.5 Amps
Iota DLS-45/IQ4 - 11 Amps
1000W Engine Heater - 8.33 Amps
1500W Engine Heater - 12.5 Amps
120V Air Compressor - 4.2 Amps
120V Dometic HVAC - 15 Amps
ELECTRICAL INLET CONNECTION
The electrical inlet shall be connected to the battery conditioner.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 45
ELECTRICAL INLET COLOR
The electrical inlet connection shall include a yellow cover.
HEADLIGHTS
The cab front shall include four (4) rectangular halogen headlamps with separate high and low
beams mounted in bright chrome bezels.
FRONT TURN SIGNALS
The front fascia shall include two (2) Techniq model K60 4.00 inch X 6.00 inch amber LED
sequential arrow turn signals which shall be installed in an outboard position within the front
fascia chrome bezel.
HEADLIGHT LOCATION
The headlights shall be located on the front fascia of the cab directly below the front warning
lights.
SIDE TURN/MARKER LIGHTS
The sides of the cab shall include two (2) Tecniq S170 LED side marker lights which shall be
provided just behind the front cab radius corners. The lights shall be amber with chrome bezels.
MARKER AND ICC LIGHTS
In accordance with FMVSS, there shall be five (5) Tecniq S170 LED cab marker lamps designating
identification, center and clearance provided. These lights shall be installed on the face of the cab
within full view of other vehicles from ground level. The lights shall be amber with chrome bezels.
HEADLIGHT AND MARKER LIGHT ACTIVATION
The headlights and marker lights shall be controlled through a rocker switch within easy reach of
the driver. There shall be a dimmer switch within easy reach of the driver to adjust the brightness
of the dash lights. The headlamps shall be equipped with the "Daytime Running" light feature,
which shall illuminate the headlights when the ignition switch is in the "On" position and the
parking brake is released.
LIGHTBAR SWITCH
The light bar shall be controlled by a rocker switch located on the switch panel. This switch shall
be clearly labeled for identification.
INTERIOR OVERHEAD LIGHTS
The cab shall include a LED dome lamp located over each door. The lights shall include push
switches on each lamp to activate both the clear and red portions of the light individually.
INTERIOR OVERHEAD LIGHTS ACTIVATION
The clear portion of each lamp shall be activated by opening the respective door.
LIGHTBAR PROVISION
There shall be one (1) light bar installed on the cab roof. The light bar shall be provided and
installed by the chassis manufacturer. The light bar installation shall include a lowered mounting
that shall place the light bar just above the junction box and wiring to a control switch on the cab
dash.
CAB FRONT LIGHTBAR
The lightbar provisions shall be for one (1) Whelen brand Freedom IV LED lightbar mounted
centered on the front of the cab roof. The lightbar shall be 72.00 inches in length. The lightbar
shall feature six (6) red LED light modules and two (2) clear LED light modules. The entire lightbar
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 46
shall feature a clear lens. The clear lights shall be disabled with park brake engaged. The cable
shall exit the lightbar on the right side of the cab.
GROUND LIGHTS
Each door shall include a Tecniq T44 LED ground light mounted to the underside of the cab step
below each door. The lights shall include a polycarbonate lens, a housing which is vibration
welded and LEDs which shall be shock mounted for extended life.
GROUND LIGHTS
The ground lighting shall be activated when the parking brake is set.
LOWER CAB STEP LIGHTS
The middle step located at each door shall include a Tecniq T44 LED light which shall activate
with the opening of the respective door. The lights shall include a polycarbonate lens, a housing
which is vibration welded and LEDs which shall be shock mounted for extended life.
INTERMEDIATE STEP LIGHTS
The intermediate step well area at the front doors shall include a TecNiq D06 LED light within a
chrome housing. The front egress step lights shall provide visibility to the step well area for the
first step exiting the vehicle. The Egress step lights shall activate with entry step lighting.
ENGINE COMPARTMENT LIGHT
There shall be a LED NFPA compliant light mounted under the engine tunnel for area work lighting
on the engine. The light shall include a polycarbonate lens, a housing which is vibration welded
and a bulb which shall be shock mounted for extended life. The light shall activate automatically
when the cab is tilted.
DO NOT MOVE APPARATUS LIGHT
The front headliner of the cab shall include a flashing red TecNiq K50 LED ligh t clearly labeled
"Do Not Move Apparatus". In addition to the flashing red light, an audible alarm shall be included
which shall sound while the light is activated.
The flashing red light shall be located centered left to right for greatest visibility.
The light and alarm shall be interlocked for activation when either a cab door is not firmly closed,
or an apparatus compartment door is not closed, and the parking brake is released.
MASTER WARNING SWITCH
A master switch shall be included in the main rocker switch panel. The switch shall be a rocker
type, red in color and labeled “Master” for identification. The switch shall feature control over all
devices wired through it. Any warning device switch left in the “ON” position shall automatically
power up when the master switch is activated.
INBOARD FRONT WARNING LIGHTS
The cab front fascia shall include two (2) Whelen C6 SurfaceMax™ series Super LED front warning
lights in the left and right inboard positions. The lights shall feature multiple f lash patterns
including steady burn for solid colors and multiple flash patterns for split colors. The lights shall
be mounted to the front fascia of the cab within a chrome bezel.
INBOARD FRONT WARNING LIGHTS COLOR
The warning lights mounted on the cab front fascia in the inboard positions shall be red with a
clear lens.
FRONT WARNING SWITCH
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 47
The front warning lights shall be controlled via rocker switch on the panel. This switch shall be
clearly labeled for identification.
INTERSECTION WARNING LIGHTS
The chassis shall include two (2) Whelen C6 SurfaceMax series Super LED intersection warning
lights, one (1) each side. The lights shall feature multiple flash patterns including steady burn for
solid colors and multiple flash patterns for split colors. The lights shall be mounted within a
chrome bezel.
INTERSECTION WARNING LIGHTS COLOR
The intersection lights shall be red with a clear lens.
INTERSECTION WARNING LIGHTS LOCATION
The intersection lights shall be mounted on the side of the cab on the front radius.
SIDE AND INTERSECTOR WARNING SWITCH
The side and intersector warning lights shall be controlled by a rocker switch on the switch
panel. This switch shall be clearly labeled for identification.
SIREN CONTROL HEAD
A Whelen 295HFS2 electronic siren control head with remote amplifier shall be provided and flush
mounted in the switch panel with a location specific to the customer’s needs. The siren shall
feature 200-watt output, hands free mode and shall be in “standby” mode awaiting
instruction. The siren shall offer radio broadcast, public address, wail, yelp, or piercer tones and
hands free operation which shall allow the operator to turn the siren on and off from the horn ring
if a horn/siren selector switch option is also selected.
AUDIBLE WARNING LH FOOT SWITCH
A foot switch wired to actuate the air horn(s) shall be supplied for installation in the front section
of the cab for driver actuation.
AIR HORN FOOT SWITCH LH
The air horn foot switch shall be a Linemaster model 491-S.
AIR HORN FOOT SWITCH LH LOCATION
The air horn foot switch shall be located on the left hand side accessible to the driver between the
steering column and the door.
AIR HORN FOOT SWITCH LH POSITION
The air horn foot switch shall be positioned inboard of any other foot switch, if applicable.
AUDIBLE WARNING LH FOOT SWITCH BRACKET
A 30.00 degree angled foot switch bracket, wide enough to accommodate (2) foot switches, shall
be installed outboard of the steering column for specified driver accessible foot switch
activations.
AUDIBLE WARNING RH FOOT SWITCH
A foot switch wired to actuate the air horn(s) shall be supplied for installation in the front section
of the cab for officer actuation.
AIR HORN FOOT SWITCH RH
The air horn foot switch shall be a Linemaster model 491-S.
AIR HORN FOOT SWITCH RH LOCATION
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 48
The air horn foot switch shall be temporarily tied up with a coiled wire drop at the firewall inboard
for installation by the customer on the right hand side accessible to the officer.
BACK-UP ALARM
An ECCO model 575 backup alarm shall be installed at the rear of the chassis with an output level
of 107 dB. The alarm shall automatically activate when the transmission is placed in reverse.
INSTRUMENTATION
An ergonomically designed instrument panel shall be provided. Each gauge shall be backlit with
LED lamps. Stepper motor movements shall drive all gauges. The instrumentation system shall
be multiplexed and shall receive ABS, engine, and transmission information over the J1939 dat a
bus to reduce redundant sensors and wiring.
A twenty eight (28) icon lightbar message center with integral LCD odometer/trip odometer shall
be included. The odometer shall display up to 999,999.9 miles. The trip odometer shall display
9,999.9 miles. The LCD message center screen shall be capable of custom configuration by the
users for displaying certain vehicle status and diagnostic functions.
The instrument panel shall contain the following gauges:
One (1) three-movement gauge displaying vehicle speed, fuel level, and Diesel Exhaust Fluid
(DEF) level. The primary scale on the speedometer shall read from 0 to 100 MPH, and the
secondary scale on the speedometer shall read from 0 to 160 KM/H. The scale on the fuel and DEF
level gauges shall read from empty to full as a fraction of full tank capacity. Red indicator lights in
the gauge and an audible alarm shall indicate low fuel or low DEF at 1/8th tank level.
One (1) three-movement gauge displaying engine RPM, and primary and secondary air system
pressures shall be included. The scale on the tachometer shall read from 0 to 3000 RPM. The
scale on the air pressure gauges shall read from 0 to 150 pounds per square inch (PSI) with a red
line zone indicating critical levels of air pressure. Red indicator lights in the gauge and an audible
alarm shall indicate low air pressure.
One (1) four-movement gauge displaying engine oil pressure, coolant temperature, voltmeter, and
transmission temperature shall be included. The scale on the engine oil pressure gauge shall
read from 0 to 100 pounds PSI with a red line zone indicating critical levels of oil pressure. A red
indicator light in the gauge and audible alarm shall indicate low engine oil pressure. The scale on
the coolant temperature gauge shall read from 100 to 250 degrees Fahrenheit (°F) with a red line
zone indicating critical coolant temperatures. A red indicator light in the gauge and audible alarm
shall indicate high coolant temperature. The scale on the voltmeter shall read from 9 to 18 volts
with a red line zone indicating critical levels of battery voltage. A red indicator light in the gauge
and an audible alarm shall indicate high or low system voltage. The low voltage alarm shall
indicate when the system voltage has dropped below 11.8 volts for more than 120 seconds in
accordance with the requirements of NFPA 1901. The scale on the transmission temperature
gauge shall read from 100 to 300 degrees °F with a red line zone indicating critical
temperatures. A red indicator light in the gauge and an audible alarm shall indicate a high
transmission temperature.
The light bar portion of the message center shall include twenty-eight (28) LED backlit
indicators. The lightbar shall be split with fourteen (14) indicators on each side of the L CD
message screen. The lightbar shall contain the following indicators and produce the following
audible alarms when supplied in conjunction with applicable configurations:
RED INDICATORS
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 49
Stop Engine - indicates critical engine fault
Air Filter Restricted - indicates excessive engine air intake restriction
Park Brake - indicates parking brake is set
Seat Belt - indicates a seat is occupied and corresponding seat belt remains unfastened
Low Coolant - indicates critically low engine coolant
Cab Tilt Lock - indicates the cab tilt system locks are not engaged.
AMBER INDICATORS
Malfunction Indicator Lamp (MIL) - indicates an engine emission control system fault
Check Engine - indicates engine fault
Check Transmission - indicates transmission fault
Anti-Lock Brake System (ABS) - indicates anti-lock brake system fault
High exhaust system temperature – indicates elevated exhaust temperatures
Water in Fuel - indicates presence of water in fuel filter
Wait to Start - indicates active engine air preheat cycle
Windshield Washer Fluid – indicates washer fluid is low
DPF restriction - indicates a restriction of the diesel particulate filter
Regen Inhibit-indicates regeneration of the DPF has been inhibited by the operator
Range Inhibit - indicates a transmission operation is prevented and requested shift request may
not occur.
SRS - indicates a problem in the supplemental restraint system
Check Message - indicates a vehicle status or diagnostic message on the LCD display requiring
attention.
GREEN INDICATORS
Left and Right turn signal indicators
ATC - indicates low wheel traction for automatic traction control equipped vehicles, also indicates
mud/snow mode is active for ATC system
High Idle - indicates engine high idle is active.
Cruise Control - indicates cruise control is enabled
OK to Pump - indicates the pump is engaged and conditions have been met for pump operations
Pump Engaged - indicates the pump transmission is currently in pump gear
Auxiliary Brake - indicates secondary braking device is active
BLUE INDICATORS
High Beam indicator
AUDIBLE ALARMS
Air Filter Restriction
Cab Tilt Lock
Check Engine
Check Transmission
Open Door/Compartment
High Coolant Temperature
High or Low System Voltage
High Transmission Temperature
Low Air Pressure
Low Coolant Level
Low DEF Level
Low Engine Oil Pressure
Low Fuel
Seatbelt Indicator
Stop Engine
Water in Fuel
Extended Left/Right Turn Signal On
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 50
ABS System Fault
BACKLIGHTING COLOR
The instrumentation gauges and the switch panel legends shall be backlit using red LED
backlighting.
CAB EXTERIOR PROTECTION
The cab face shall have a removable plastic film installed over the painted surfaces to protect the
paint finish during transport to the body manufacturer.
FIRE EXTINGUISHER
A 2.50 pound D.O.T approved fire extinguisher with BC rating shall be shipped loose with the cab.
DOOR KEYS
The cab and chassis shall include a total of four (4) door keys for the manual door locks.
WARRANTY
Purchaser shall receive a Custom Chassis One (1) Year or 18,000 Miles limited warranty in
accordance with, and subject to, warranty certificate RFW0101. The warranty certificate is
incorporated by reference into this proposal, and included with this proposal or available upon
request.
CHASSIS OPERATION MANUAL
There shall be two (2) digital copies of the chassis operation manual provided with the chassis.
The digital data shall include a parts list specific to the chassis model.
ENGINE AND TRANSMISSION OPERATION MANUALS
The following manuals specific to the engine and transmission models ordered will be included
with the chassis in the ship loose items:
(1) Hard copy of the Engine Operation and Maintenance manual with USB flash drive
(1) Digital copy of the Transmission Operator’s manual on USB flash drive
(1) Digital copy of the Engine Owner’s manual on USB flash drive
CAB/CHASSIS AS BUILT WIRING DIAGRAMS
The cab and chassis shall include two (2) digital copies of wiring schematics and option wiring
diagrams.
SALES TERMS
The sale of the chassis shall be governed by the terms contained on the Sales Terms –
Acceptance of Purchase Order document, a copy of which is attached to this option.
PO00010573 - FUEL POCKET, DRIVER SIDE REAR WHEEL WELL PANEL
QTY: 1.00
A fuel fill shall be provided in the driver side rear wheel well area.
A Cast Products heavy duty cast aluminum spring loaded hinged fill door shall be provided.
A label indicating "Ultra Low Sulfur Diesel Fuel Only" shall be provided adjacent to the fuel fill.
PO00022590 - 12 VOLT ELECTRICAL SYSTEM TESTING - ALL UNITS
QTY: 1.00
The apparatus low voltage electrical system shall be tested and certified by the manufacturer. The
certification shall be provided with the apparatus. All tests shall be performed with the air temperature
between 0°F and 100°F.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 51
The following three (3) tests shall be performed in order. Before each test, the batteries shall be fully
charged.
The engine shall be started and kept running until the engine and engine compartment temperatures are
stabilized at normal operating temperatures and the battery system is fully charged. The engine shall be
shut off and the minimum continuous electrical load shall be activated for 10 minutes. All electrical loads
shall be turned off prior to attempting to restart the engine. The battery system shall then be capable of
restarting the engine. Failure to restart the engine shall be considered a test failure.
The minimum continuous electrical load shall be activated with the engine running at idle speed. The
engine temperature shall be stabilized at normal operating temperature. The battery system shall be
tested to detect the presence of battery discharge current. The detection of battery discharge current shall
be considered a test failure.
The total continuous electrical load shall be activated with the engine running up to the engine
manufacturers governed speed. The test duration shall be a minimum of 2 hours. Activation of the load
management system shall be permitted during this test. However, an alarm sounded due to excessive
battery discharge, as detected by the system, or a system voltage of fewer than 11.7 volts DC for a 12 -
volt system, for more than 120 seconds, shall be considered a test failure.
Following completion of the preceding tests, the engine shall be shut off. The total continuous electrical
load shall be activated and shall continue to be applied until the excessive battery discharge alarm is
activated.
The battery voltage shall be measured at the battery terminals. With the load still applied, a reading of
fewer than 11.7 volts shall be considered a test failure. The battery system shall then be able to restart
the engine.
At the time of delivery, documentation shall be provided with the following information:
• Documentation of the electrical system performance test
• A written load analysis of the following;
• Nameplate rating of the alternator
• Alternator rating at idle while meeting the minimum continuous electrical load
• Each component load comprising the minimum continuous electrical load.
• Additional loads that, when added to the minimum continuous load, determine the total connected
load.
• Each individual intermittent load.
PO00011799 - DIRECT BATTERY GROUNDING STRAP
QTY: 1.00
Direct grounding straps shall be mounted to the following areas; frame to cab, frame to body and frame to
pump enclosure.
All exposed electrical connections shall be coated with "Z-Guard 8000" to prevent corrosion.
PO00010737 - DELETE BODY STEP LIGHTS - LIGHTED STEPS SELECTED
QTY: 1.00
PO00010735 - HOSE BED WORK LIGHT - SWITCH
QTY: 1.00
The hose bed work light shall have a protected 12-volt switch at the rear body panel.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 52
The switch will be labeled "HOSE BED WORK LIGHTS."
***SPECIAL: SP00040468 - REAR SCENE LIGHT SWITCH - RECESSED
QTY: 1.00
A switch shall be provided at the rear of the body for the rear scene lights. The switch shall be
installed in a recessed pocket that shall be painted to match the body color.
PO00003389 - CONTROL SWITCHES ON PUMP PANEL FOR REAR OF CAB LIGHTS
QTY: 1.00
Two (2) switches shall be provided on the pump panel to turn the rear of cab lights on and off.
One (1) switch shall control the driver side light and one (1) switch shall control the offic er side light.
PO00003234 - CONTROL SWITCH IN CAB FOR 12 V REAR OF BODY SCENE LIGHTS
QTY: 1.00
Controls shall be provided in the cab control system (or optional mechanical switch) to turn the rear of
body lights on and off.
PO00003240 - CONTROL SWITCH IN CAB FOR 12 V DRIVER SIDE OF BODY SCENE LIGHTS
QTY: 1.00
Controls shall be provided in the cab control system (or optional mechanical switch) to turn the driver side
of body lights on and off.
PO00003242 - CONTROL SWITCH IN CAB FOR 12 V OFFICER SIDE OF BODY SCENE LIGHTS
QTY: 1.00
Controls shall be provided in the cab control system (or optional mechanical switch) to turn the officer
side of body lights on and off.
***SPECIAL: SP00041049 - AKRON SCENESTAR 150W TELESCOPING W/POLES, 12V - REAR OF
FC-94
QTY: 1.00
Two (2) Akron SceneStar, ELSS-SLDC, 150 watt, 12 volt, LED flood lights shall be installed, one (1)
on each side, on the rear of the cab, each using a Extenda-Lite, side mount, telescoping pole.
Each lamp head shall draw 12 amps and generate 14,000 lumens.
Each light shall be switched at the light head.
PO00003399 - WIRE UPGRADE FOR 12V HIGH AMP LIGHTS - REAR OF CAB
QTY: 1.00
PO00010755 - NFPA COMPLIANT WARNING LIGHT PACKAGE
QTY: 1.00
The following warning light package shall include all of the minimum warning light and actuation
requirements for the current revision of the NFPA 1901 Fire Apparatus Standard.
The lighting as specified shall meet the requirements for both "Clearing Right of Way" and "Blocking Right
of Way" which includes disabling all white warning lights when the apparatus is in "Blocking Right of Way"
mode.
PO00010757 - WARNING LIGHT FLASH PATTERN - NFPA FLASH PATTERN
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 53
All of the perimeter warning lights shall be set to a default NFPA compliant flash pattern as provided by
the light manufacturer.
PO00010756 - LIGHT PACKAGE ACTUATION/CONTROLS
QTY: 1.00
The entire warning light package shall be actuated with a single warning light switch located on the cab
switch panel. The wiring for the warning light package shall engage all of the lights required for "Clearing
Right of Way" mode when the vehicle parking brake is not engaged. An automatic control system shall
be provided to switch the warning lights to the "Blocking Right of Way" mode when the vehicle parking
brake is engaged.
PO00010759 - LIGHT PACKAGE NFPA CERTIFICATION
QTY: 1.00
The warning light system(s) specified above shall not exceed a combined total amperage draw of 45
AMPS with all lights activated in either the "Clearing Right of Way" or the "Blocking Right of Way"
The warning light system(s) shall be certified by the light system manufacturer(s), to meet all of the
requirements in the current revision of the NFPA 1901 Fire Apparatus Standard as noted in the General
Requirements section of these specifications.
The NFPA required "Certificate of Compliance" shall be provided with the completed apparatus.
Any large truck as defined by NFPA shall have the lower zone warning lights mounted no higher than 62"
to the optical center of the warning light from ground level. {No Exceptions}
PO00003639 - C-UPPER, WHELEN C9 SUPER LEDS
QTY: 1.00
Two (2) Whelen, C9, super LED light heads shall be furnished and mounted one (1) on each side on the
upper rear face of the body, facing rear.
PO00024573 - UPPER ZONE C WARNING LIGHT LENS - RED
QTY: 1.00
The upper zone C warning lights shall include red LEDs and a red lens if available from the manufacturer.
If a red lens is unavailable, a clear lens shall be included.
PO00024593 - UPPER ZONE C WARNING LIGHT BEZEL - CHROME
QTY: 1.00
The upper zone C warning lights shall include a chrome bezel if available from the manufacturer. If a
chrome bezel is unavailable, a black bezel shall be included.
PO00003662 - B/D-UPPER FRONT, COVERED BY LIGHTS IN ZONE A-UPPER
QTY: 1.00
The lighting requirement for this area is covered by the lights noted in Zone "A" - Upper.
PO00003651 - B/D-UPPER REAR, WHELEN C6 SUPER LEDS
QTY: 1.00
Two (2) Whelen, C6 super LED light heads shall be furnished and mounted one (1) on each side on the
upper side face, towards the rear of the body, facing to each side of the unit.
The lights shall be installed with a chrome plated mounting flange.
PO00024577 - UPPER ZONE B/D REAR WARNING LIGHT LENS - RED
QTY: 1.00
The upper zone B/D rear warning lights shall include red LEDs and a red lens if available from the
manufacturer. If a red lens is unavailable, a clear lens shall be included.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 54
PO00024597 - UPPER ZONE B/D REAR WARNING LIGHT BEZEL - CHROME
QTY: 1.00
The upper zone B/D rear warning lights shall include a chrome bezel if available from the manufacturer. If
a chrome bezel is unavailable, a black bezel shall be included.
PO00003878 - C-LOWER REAR, WHELEN C6 SUPER LEDS
QTY: 1.00
Two (2) Whelen, C6, super LED light heads shall be provided and installed one (1) each side directly
below the DOT stop, tail, turn and backup lights.
PO00024581 - LOWER ZONE C WARNING LIGHT LENS - RED
QTY: 1.00
The lower zone C warning lights shall include red LEDs and a red lens if available from the manufacturer.
If a red lens is unavailable, a clear lens shall be included.
PO00003903 - B/D-LOWER MID, WHELEN C6 SUPER LEDS
QTY: 1.00
Two (2) Whelen, C6 super LED light heads shall be provided and installed with one (1) on each side.
PO00024585 - LOWER ZONE B/D MID WARNING LIGHT LENS - RED
QTY: 1.00
The lower zone B/D mid warning lights shall include red LEDs and a red lens if available from the
manufacturer. If a red lens is unavailable, a clear lens shall be included.
PO00024605 - LOWER ZONE B/D MID WARNING LIGHT BEZEL - CHROME
QTY: 1.00
The lower zone B/D mid warning lights shall include a chrome bezel if available from the manufacturer. If
a chrome bezel is unavailable, a black bezel shall be included.
PO00003925 - B/D-LOWER REAR, WHELEN C6 SUPER LEDS
QTY: 1.00
Two (2) Whelen C6 super LED light heads shall be provided and installed with one (1) on each side.
PO00024587 - LOWER ZONE B/D REAR WARNING LIGHT LENS - RED
QTY: 1.00
The lower zone B/D rear warning lights shall include red LEDs and a red lens if available from the
manufacturer. If a red lens is unavailable, a clear lens shall be included.
PO00024607 - LOWER ZONE B/D REAR WARNING LIGHT BEZEL - CHROME
QTY: 1.00
The lower zone B/D rear warning lights shall include a chrome bezel if available from the manufacturer. If
a chrome bezel is unavailable, a black bezel shall be included.
PO00003298 - GROUND LIGHTS, 2 LED BELOW PUMP PANEL RUNNING BOARD - TECNIQ E10
QTY: 1.00
One (1) TecNiq LED, 6" long ground light with stainless steel mounting bracket, shall be provided under
each side pump panel running board, two (2) total.
PO00003301 - GROUND LIGHTS, 2 LED AT REAR BODY CORNERS - TECNIQ E10
QTY: 1.00
One (1) TecNiq LED, 6" long ground light with stainless steel mounting bracket, shall be provided under
each rear body corner, two (2) total.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 55
PO00026832 - CAB AND BODY GROUND LIGHTS ACTIVATE AS PROVIDED BY CHASSIS
MANUFACTURER
QTY: 1.00
Ground light activation shall be as provided by the chassis manufacturer and shall be wired through the
load management system.
PO00011821 - BODY ELECTRICAL SYSTEM
QTY: 1.00
All electrical lines in the body shall be protected by automatic circuit breakers, conveniently located to
permit ease of service.
Flashers, heavy solenoids and other major electrical controls shall be located in a central area near the
circuit breakers.
All lines shall be color and function coded every 3", easy to identify, oversized for the intended loads and
installed in accordance with a detailed diagram.
A complete wiring diagram shall be supplied with the apparatus.
Wiring shall be carefully protected from weather elements and snagging. Heavy duty loom shall be used
for the entire length.
Grommets shall be utilized where wiring passes through panels.
In order to minimize the risk of heat damage, wires run in the engine compartment area s hall be carefully
installed and suitably protected by the installation of heat resistant shielded loom.
All electrical equipment shall be installed to conform to the latest federal standards as outlined in NFPA
1901.
PO00010752 - BODY ELECTRICAL HARNESS - V-MUX
QTY: 1.00
PO00026555 - BLUE SEA FUSE BLOCK IN BODY COMPARTMENT - BATTERY POWER
QTY: 1.00
The Blue Sea fuse block(s) installed in the body shall have the power source connected directly to
battery.
PO00025517 - BLUE SEA FUSE BLOCK - 6 CIRCUIT FORWARD WALL L1
QTY: 1.00
A Blue Sea 5025B, 6 circuit fuse block, shall be installed on the upper forward wall of the body L1
compartment interior.
This block has a maximum amperage of 60 Amps per block and 30 Amps per circuit.
PO00025540 - BLUE SEA FUSE BLOCK - 6 CIRCUIT FORWARD WALL R3
QTY: 1.00
A Blue Sea 5025B, 6 circuit fuse block, shall be installed on the upper forward wall of the body R3
compartment interior.
This block has a maximum amperage of 60 Amps per block and 30 Amps per circuit.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 56
PO00009693 - DUNNAGE AREA LIGHTING, TECNIQ EON 3 LED
QTY: 1.00
Two (2) stainless steel, TecNiq Eon 3-LED horizontal surface mounted lights shall be provided in the
dunnage area to provide adequate illumination of this area.
These lights shall be switched in the same manner as the step lights.
PO00011816 - COMPARTMENT LIGHT ACTIVATION
QTY: 1.00
Compartment lighting shall be switched either from an integral switch as provided by the roll up door
manufacturer or a magnetic proximity switch if it is a KME manufactured door.
PO00003419 - COMPARTMENT LIGHTS, AMDOR LUMA BAR LED LIGHTING - SINGLE
QTY: 7.00
Each individual, equipment storage compartment shall be equipped with the AMDOR Luma Bar, LED light
fixture, mounted on the forward (or rearward) vertical door frame.
PO00002999 - MARKER/TURN LIGHTS @ EA SIDE OF BODY
QTY: 1.00
Red, LED marker lights with integral reflectors shall be provided at the lower side rear, having one (1) on
each side.
Yellow, LED side marker and turn lights shall be provided on the apparatus lower side, forward of rear
axle that puts one (1) on each side, if the apparatus is 30' long or longer.
PO00003003 - DOT MARKER LIGHTS @ REAR OF BODY
QTY: 1.00
Red, LED clearance lights shall be provided on the apparatus rear upper having one (1) on each side at
the outermost practical location.
Red, LED, 3-lamp identification bar will be provided on the apparatus rear center.
PO00003007 - DOT AMBER REFLECTORS @ SIDE OF BODY
QTY: 1.00
Yellow reflectors shall be provided on the apparatus body lower side, as far forward and low as practical
with one (1) on each side if the apparatus is 30' long or longer.
PO00003008 - DOT RED REFLECTORS @ REAR OF BODY
QTY: 1.00
Red reflectors shall be provided on the apparatus rear with one (1) on each side at the outermost
practical location.
PO00026701 - TECNIQ #L10 LED LICENSE PLATE LIGHT
QTY: 1.00
One (1) Tecniq model #L10 LED license plate light shall be provided above the mounting position of the
license plate. The license plate shall be located on the driver's side rear of body.
The light shall be clear in color and shall have a chrome finish.
PO00003037 - WHELEN C6 LED BRAKE, REVERSE, TURN W/ QUAD HOUSING
QTY: 1.00
Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED red combination tail and stop lights, shall be mounted one
each side at the rear of the body.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 57
Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED amber arrow turn signal lights, shall be mounted one
each side, on a vertical plane with the tail/stop lights.
Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED white back-up lights, shall be mounted one each side on
a vertical plane with the turn/tail/stop signals.
These lights shall activate when the transmission is placed in reverse gear.
Two (2) Whelen PLASC4V mounting flanges, installed one (1) on each side, shall be provided to mount
the lights described above in one common mounting flange.
The fourth opening shall be for the lower rear warning lights.
The lights shall be mounted in order, from top to bottom, as described above.
PO00003402 - PUMP ENCLOSURE WORK LIGHTS - TECNIQ LED
QTY: 1.00
Two (2) Tecniq, model #E18 lights shall be provided inside the pump enclosure, providing 800 lumens
each.
Each light shall have their own independent switch incorporated into the light head.
PO00003106 - AMDOR LED STRIP HOSE BED LIGHT-FRONT HOSEBED WALL
QTY: 1.00
One (1) Amdor, LED, strip surface mounted lights shall be mounted in the hose bed on the front wall to
illuminate the hose bed area.
PO00003179 - WHELEN C6 SERIES LED SCENE LIGHTS ON REAR OF BODY
QTY: 1.00
Two (2) Whelen, # C6, super LED scene lights shall be provided, (1) one on each side of the rear body
panel in a chrome plated flange.
The scene lights shall be controlled by a rocker switch in the master warning light switch console.
All scene lights shall be wired through the load management system.
PO00003182 - WHELEN C6 SERIES LED SCENE LIGHTS ON DRIVER SIDE OF BODY
QTY: 1.00
Two (2) Whelen, # C6, super LED scene lights shall be provided.
The scene lights shall be installed one rearward and one forward on the driver side of the body in a
chrome plated flange.
The scene lights shall be wired through the load management system.
PO00003183 - WHELEN C6 SERIES LED SCENE LIGHTS ON OFFICER SIDE OF BODY
QTY: 1.00
Two (2) Whelen, # C6, super LED scene lights shall be provided.
The scene lights shall be installed, one rearward and one forward, on the officer side of the body in a
chrome plated flange.
The scene lights shall be wired through the load management system.
PO00003552 - WIRE UPGRADE FOR 12V HIGH AMP LIGHTS - REAR OF DUNNAGE
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 58
QTY: 1.00
PO00012247 - FEDERAL Q2B SIREN @ CAB FRONT
QTY: 1.00
One (1) Federal Model #Q2B mechanical siren shall be provided to provide audible warning.
PO00012253 - Q2B MOUNT - SEMI-RECESSED INTO DRIVER'S SIDE OF BUMPER
QTY: 1.00
The Q2B siren shall be semi-recessed into the bumper on the driver's side.
The siren shall be recessed so the front grille portion of the siren is exposed and protruding beyond the
bumper.
PO00026753 - ELECTRO/MECHANICAL SIREN BRAKE CONTROL - DASH SWITCH, DRIVER SIDE
QTY: 1.00
A dash mounted push button switch shall be provided for the driver to control the brake on the
electro/mechanical siren.
PO00026761 - ELECTRO/MECHANICAL SIREN CONTROL - FLOOR SWITCH, DRIVER SIDE
QTY: 1.00
A floor mounted foot switch shall be provided for the driver to activate the electro/mechanical siren.
PO00026764 - ELECTRO/MECHANICAL SIREN CONTROL - FLOOR SWITCH, OFFICER SIDE
QTY: 1.00
A floor mounted foot switch shall be provided for the officer to activate the electro/mechanical siren.
PO00004695 - HALE QMAX-150 1500 GPM SINGLE STAGE PUMP
QTY: 1.00
• HALE QMAX-150
• 1500 G.P.M.
Single Stage The pump must deliver the percentage of rated capacity at the pressure listed below:
• 100% of rated capacity at 150 P.S.I. net pump pressure
• 100% of rated capacity at 165 P.S.I. net pump pressure
• 70% of rated capacity at 200 P.S.I. net pump pressure
• 50% of rated capacity at 250 P.S.I. net pump pressure.
The pump shall be of a size and design to mount on the chassis rails of commercial and custom truck
chassis and have the capacity of 1500 gallons per minute (U.S. GPM), NFPA-1901 rated performance.
The entire pump shall be manufactured and tested at the pump manufacturer's factory. The pump shall
be driven by a drive line from the truck transmission. The engine shall provide sufficient horsepower and
RPM to enable the pump to meet and exceed its rated performance. The entire pump both suction and
discharge passages, shall be hydrostatically tested to a pressure of 600 PSI. The pump shall be fully
tested at the pump manufacturer's factory to performance specs as outlined by the latest NFPA -1901.
Pump shall be free from objectionable pulsation and vibration. The pump body and related parts shall be
of fine grain alloy cast iron with a minimum tensile strength of 30,000 PSI. All moving parts in contact with
water shall be of high quality bronze or stainless steel. Pumps utilizing castings made of lower tensile
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 59
strength cast iron are not acceptable. Pump body shall be horizontally split, on a single plane in two
sections for easy removal of entire impeller assembly including wear rings and bearings from beneath the
pump without disturbing piping or the mounting of the pump in chassis.
Pump shaft to be rigidly supported by three bearings for minimum deflection. One high lead bronze
sleeve bearing shall be located immediately adjacent to the impeller (on side opposite the gearbox). The
sleeve bearing is to be lubricated by a force fed, automatic oil lubricated design, pressure balanced to
exclude foreign material. The pump shaft shall be heat-treated, electric furnace, corrosion resistant
stainless steel to be super-finished under packing with galvanic corrosion (zinc foil separators in packing)
protection for longer shaft life. Pump shaft must be sealed with double-lip oil seal to keep road dirt and
water out of gearbox.
The pump shall have one double suction impeller. The pump body shall have two opposed discharge
volute cutwaters to eliminate radial unbalance. Pump impeller shall be hard, fine grain bronze of the
mixed flow design, accurately machined, and individually balanced. The vanes of the impeller intake eyes
shall be of sufficient size and design to provide ample reserve capacity utilizing minimum horsepower.
Impeller clearance rings shall be bronze, easily renewable without replacing impeller or pump volute
body, and of wrap-around double labyrinth design for maximum efficiency.
PO00010792 - PUMP RATIO
QTY: 1.00
The pump ratio shall be selected by the apparatus manufacturer to give maximum performance with the
engine and transmission selected.
The manufacturer shall supply at time of delivery copies of the pump manufacturer's certification of
hydrostatic testing, the engine manufacturer's current certified brake horsepower curve.
PO00009802 - PUMP MOUNTS - MID-SHIP PUMPS
QTY: 1.00
Extra heavy duty pump mounting brackets shall be furnished.
These shall be bolted to the frame rails in such a position to perfectly align the pump so that the angular
velocity of the drive line joints shall be the same on each end of the drive shaft.
This shall assure full capacity performance with a minimum of vibration. Mounting hardware shall utilize
Grade 8 bolts.
PO00009138 - HALE MECHANICAL PUMP SEAL
QTY: 1.00
The mid ship pump shall be equipped with a high quality, spring loaded, self-adjusting mechanical seal
capable of providing a positive seal to atmosphere under all pumping conditions.
This positive seal to atmosphere must be achievable under vacuum conditions up to 26 Hg (draft) or
positive suction pressures up to 250 PSI.
The mechanical seal assembly shall be 2 inches in diameter and consists of a carbon sealing ring,
stainless steel coil spring,
Viton rubber boot, and a tungsten carbide seat with a Teflon backup seal provided.
Only one (1) mechanical seal shall be required, located on the first stage suction (inboard) side of the
pump and be designed to be compatible with a one piece pump shaft.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 60
A continuous cooling flow of water from the pump shall be directed through the seal chamber when the
pump is in operation.
PO00009105 - HALE PUMP "G" DRIVE UNIT, ALL HALE FULL CAST PUMPS
QTY: 1.00
The drive unit shall be completely assembled and tested at the pump manufacturer's factory.
Pump drive unit shall be of sufficient size to withstand up to 16,000 lbs. ft. of torque of the engine in both
road and pump operating conditions.
The drive unit shall be designed of ample capacity for lubrication reserve and to maintain the proper
operating temperature.
The gearbox drive shafts shall be of heat treated chrome nickel steel and at least 2-3/4 inches in diameter
on both the input and output drive shafts.
They shall withstand the full torque of the engine in both road and pump operating conditions.
All gears, both drive and pump, shall be of the highest quality electric furnace chrome nickel steel.
Bores shall be ground to size and teeth integrated, chrome-shaven and hardened, to give an extremely
accurate gear for long life, smooth, quiet running and higher load carrying capability.
An accurately cut spur design shall be provided to eliminate all possible end thrust.
PO00026827 - PUMP SHIFT MANUAL OVERRIDE
QTY: 1.00
An emergency manual pump shift control shall be furnished on the left side pump panel which may be
utilized if the air shift control does not operate.
PO00012078 - HALE PUMP SHIFT INDICATOR LIGHTS
QTY: 1.00
For automatic transmissions, three (3) green warning lights shall be provided to indicate to the operator(s)
when the pump has completed the shift for Road to Pump position.
Two (2) green lights to be located in the truck driving compartment and one (1) green light on pump
operator's panel adjacent to the throttle control.
For manual transmissions, one (1) green warning light shall be provided for the driving compartment.
All lights to have appropriate identification/instruction plates.
PO00010750 - AUXILIARY ENGINE COOLER
QTY: 1.00
An auxiliary cooler or heat exchanger shall be installed in the engine compartment between the engine
and the chassis radiator.
The cooler shall permit the use of water from the pump for cooling the engine.
The cooling shall be done without mixing engine and pump water.
PO00004811 - FIRE RESEARCH "IN CONTROL" TGA-300 PRESSURE GOVERNOR
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 61
The apparatus shall be equipped with a Fire Research InControl series TGA300 pressure governor and
monitoring display kit shall be installed. The kit shall include a control module, intake pressure sensor,
discharge pressure sensor, and cables. The control module case shall be waterproo f and have
dimensions not to exceed 5 1/2" high by 10 1/2" wide by 2" deep. Inputs for monitored information shall
be from a J1939 databus or independent sensors. Outputs for engine control shall be on the J1939
databus or engine specific wiring.
The following continuous displays shall be provided:
• Pump discharge; shown with four daylight bright LED digits more than 1/2" high
• Pump Intake; shown with four daylight bright LED digits more than 1/2" high
• Pressure / RPM setting; shown on a dot matrix message display
• Pressure and RPM operating mode LEDs
• Throttle ready LED
• Engine RPM; shown with four daylight bright LED digits more than 1/2" high
• Check engine and stop engine warning LEDs
• Oil pressure; shown on a dual color (green/red) LED bar graph display
• Engine coolant temperature; shown on a dual color (green/red) LED bar graph display
• Transmission Temperature: shown on a dual color (green/red) LED bar graph display
• Battery voltage; shown on a dual color (green/red) LED bar graph display.
• The dot-matrix message display shall show diagnostic and warning messages as they occur. It shall
show monitored apparatus information, stored data, and program options when selected by the
operator. All LED intensity shall be automatically adjusted for day and night time operation.
The program shall store the accumulated operating hours for the pump and engine to be displayed with
the push of a button. It shall monitor inputs and support audible and visual warning alarms for the
following conditions:
• High Battery Voltage
• Low Battery Voltage (Engine Off)
• Low Battery Voltage (Engine Running)
• High Transmission Temperature
• Low Engine Oil Pressure
• High Engine Coolant Temperature
• Out of Water (visual alarm only)
• No Engine Response. (visual alarm only)
The program features shall be accessed via push buttons located on the front of the control panel. There
shall be an USB port located at the rear of the control module to upload future firmware enhancements.
Inputs to the control panel from the pump discharge and intake pressure sensors shall be electrical. The
discharge pressure display shall show pressures from 0 to 600 psi. The intake pressure display shall
show pressures from -30 in. Hg to 600 psi.
The governor shall operate in two control modes, pressure and RPM. No discharge pressure or engine
RPM variation shall occur when switching between modes. A throttle ready LED shall light when the
interlock signal is recognized. The governor shall start in pressure mode and set the engine RPM to
idle. In pressure mode the governor shall automatically regulate the discharge pressure at the level set
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 62
by the operator. In RPM mode the governor shall maintain the engine RPM at the level set by the
operator except in the event of a discharge pressure increase. The governor shall limit a discharge
pressure increase in RPM mode to a maximum of 30 psi. Other safety features shall include recognition
of no water conditions with an automatic programmed response and a push button to return the engine to
idle.
The pressure governor, monitoring, and master pressure display shall be programmed to interface with a
specific engine.
PO00011415 - TASK FORCE TIPS #A18 SERIES INTAKE RELIEF VALVE
QTY: 1.00
A Task Force Tips relief valve shall be provided.
The valve shall be adjustable from 50 to 300 psi (3 to 14 bar) with easy to see 25 psi (2 bar) increments.
The aluminum casting shall be hardcoat anodized, and powder coat finished inside and out for maximum
corrosion protection.
PO00009890 - TRIDENT "MANUAL" AIR PRIMING SYSTEM
QTY: 1.00
The priming pump will be a Trident air primer system.
A push in primer handle will open the priming valve and prime the pump.
PO00004825 - ROTARY MASTER DRAIN VALVE
QTY: 1.00
A rotary type, 12 port, master drain valve shall be provided and controlled at the lower portion of the side
pump panel.
The valve shall be located in pump compartment lower than the main body and connected in such a
manner as to allow complete water drainage of the pump body and all required accessories.
Water shall be drained below the apparatus body and away from the pump operator.
PO00004830 - DRAINS/BLEEDER "INNOVATIVE CONTROLS" LIFT UP @ ALL 1-1/2" OR LARGER
QTY: 1.00
All lines shall drain through the master drain valve or shall be equipped with individual drain valves, easily
accessible, and labeled.
One (1) individual "Innovative Control" lift up drain valve shall be furnished for each 1- 1/2" or larger
discharge port and each 2-1/2" gated auxiliary suction.
Drain/bleeder valves shall be located at the bottom of the side pump module panels. All drains and
bleeders shall discharge below the running boards.
PO00004840 - SYNFLEX SUCTION, DISCHARGE, PRESSURE AND CONTROL LINES
QTY: 1.00
Small lines within the pump enclosure shall be constructed from Synflex hose.
Uses include but are not limited to such lines as priming control, gauge lines, drain lines, air control
valves, pump shift, supplemental cooling, foam flush, and air bleeder valves.
PO00010965 - SUCTION INLETS - 6” INLETS
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 63
Two (2) 6" N.S.T. suction inlets shall be provided, one on the driver side and one on the officer side pump
panel.
A removable strainer shall be installed on each inlet.
PO00024018 - SHORT NECK MAIN PUMP SUCTION INLETS
QTY: 1.00
The main pump suction inlets shall be furnished with a short suction end, terminating with only the suction
threads protruding through the side panel to minimize the distance an exterior appliance protrudes
beyond the pump panel.
PO00012076 - BEHIND PANEL MOUNT
QTY: 1.00
All side gated inlet valves shall be recess mounted behind the side pump panels or body panels. There
will be no exceptions.
PO00023976 - 6" NST INTAKE CAP - DRIVER SIDE
QTY: 1.00
A 6" NST chrome plated long handle pressure vented cap shall be installed on driver side intake.
PO00023980 - 6" NST INTAKE CAP - OFFICER SIDE
QTY: 1.00
A 6" NST chrome plated long handle pressure vented cap shall be installed on officer side intake.
PO00011333 - 2-1/2" DRIVER SIDE AUX PRIMARY SUCTION INLET FORWARD OF MAIN
QTY: 1.00
One (1) 2-1/2" auxiliary suction shall be provided at the driver side pump panel, to the front of the main
inlet.
The 2-1/2" auxiliary suction shall terminate with a removable strainer, chrome plated 2- 1/2" NST female
swivel with a chrome plated plug and retaining chain.
PO00004969 - 2-1/2" AKRON #8800 S.S. BALL VALVE, DRIVER SIDE FRONT AUX SUCTION
QTY: 1.00
An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side front auxiliary
suction.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00004984 - SWING CONTROL @ VALVE, DRIVER SIDE FRONT AUX SUCTION
QTY: 1.00
A 1/4 turn swing control handle shall be provided on the driver side, front auxiliary suction valve.
PO00011335 - 2-1/2" OFFICER SIDE AUX SUCTION INLET FORWARD OF MAIN
QTY: 1.00
One (1) 2-1/2" auxiliary suction shall be provided at the officer side pump panel, to the front of the main
inlet (if space and other components allow).
The 2-1/2" auxiliary suction shall terminate with a removable strainer, chrome plated 2- 1/2" NST female
swivel with a chrome plated plug and retaining chain.
PO00023917 - 2-1/2" AKRON #8800 S.S. BALL VALVE, OFFICER SIDE FRONT AUX SUCTION
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 64
An Akron Brass 2 1/2" Generation II Swing-Out™ Valve (will/shall) be provided for the officer's side front
auxiliary suction. The valve (will/shall) have an all-brass body with flow optimizing stainless steel ball and
dual polymer seats.
PO00009373 - SWING CONTROL @ VALVE, OFFICER SIDE AUX SUCTION
QTY: 1.00
A 1/4 turn swing control handle shall be provided on the officer side auxiliary suction valve.
PO00011323 - TANK TO PUMP
QTY: 1.00
One (1) 4" tank to pump line shall be piped through the front bulkhead of the tank with a 90 degree elbow
down into the tank sump.
This line shall be plumbed directly into the rear of the pump suction manifold for maximum efficiency.
A check valve shall be provided to prevent accidental pressurization of the water tank through the pump
connection.
Connection from the valve to the tank shall be made by using a non-collapsible flexible rubber hose.
PO00004999 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE , TANK TO PUMP
QTY: 1.00
An Akron Brass 3" Generation II Swing-Out Valve shall be provided between the pump suction manifold
and the water tank.
The valve shall have an all brass body with flow optimizing, stainless steel ball and dual polymer seats.
PO00010956 - 3" PUSH/PULL CONTROL FOR TANK TO PUMP
QTY: 1.00
A push/pull control handle shall be located on the operator's panel with function plate.
PO00010962 - TANK FILL LINE 2" FROM PUMP - SIDE MOUNT
QTY: 1.00
One (1) 2" gated full flow pump to tank refill line controlled at the pump panel shall be provided. A
deflector shield inside the tank shall be furnished. Tank fill plumbing shall utilize 2" high pressure hose for
tank connection to accommodate flexing between components. There will be no exceptions.
PO00005031 - 2" AKRON #8800 SERIES - S.S. BALL TANK FILL, SIDE MOUN
QTY: 1.00
An Akron Brass 2" Generation II Swing-Out Valve shall be provided between the pump discharge
manifold and the water tank.
The valve shall have an all brass body with flow optimizing, stainless steel ball, and dual polymer seats.
PO00011330 - TOP MOUNT SWING CONTROL FOR TANK FILL - TOP MOUNT
QTY: 1.00
A locking push/pull swing control handle shall be located on the operator's panel with function plate.
PO00012083 - DRIVER SIDE MAIN DISCHARGE #1
QTY: 1.00
A discharge shall be provided and located at the driver's side pump panel.
The driver's side discharges # 1 shall terminate with NST threads, through the left panel above the main
pump intake.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 65
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct
connect discharge valve flanges.
PO00009226 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #1
QTY: 1.00
An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #1 discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00005039 - DS #1 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW
QTY: 1.00
The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2
1/2" NST, 30-degree, chrome plated elbow.
PO00005050 - 2-1/2" NST PRESSURE VENTED CAP - DRIVER SIDE DISCHARGE #1
QTY: 1.00
A 2 1/2 " NST, chrome plated pressure vented cap shall be installed on driver's side #1 discharge.
PO00005093 - 2-1/2" AKRON #9335 ELECTRIC VALVE CONTROL FOR DRIVER SIDE DISCHARGE
#1
QTY: 1.00
The driver's side # 1 discharge Akron ball valve shall be equipped with an Akron Br ass Style 9335
Navigator Pro Valve Controller.
The electric controls shall be of current limiting design, requiring no clutches in the motor.
Unit shall have booted switches with momentary open and close as well as an optional one touch full
open feature to operate the actuator.
Three additional buttons shall be available to be used for preset selection, preset activation, CAFS
activation, and menu navigation.
The unit shall be equipped with a flow/pressure Meter.
The meter shall have a flow range up to 2500 GPM (9500 LPM) and a maximum hydrostatic pressure of
600 PSI (41.4 bar).
The unit shall have programmed pipe sizes and be capable of custom calibration to high and low flow
ranges.
The unit shall be capable of turning on and off a solenoid used in a CAFS system.
The only calibration required is to set the unit to the valve during initial set up. No other calibration shalll
be required.
The display shall be a full color, backlit, LCD display.
It shall have manual adjustment of the brightness as well as an auto-dimming option.
A stainless steel flow sensor paddle wheel shall be installed in the discharge pipe with a machined
housing or clamp.
PO00012084 - DRIVER SIDE MAIN DISCHARGE #2
QTY: 1.00
A discharge shall be provided and located at the driver's side pump panel.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 66
The driver's side discharges # 2 shall terminate with NST threads, through the left panel above the main
pump intake.
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct
connect discharge valve flanges.
PO00009304 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #2
QTY: 1.00
An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #2 discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00005145 - DS #2 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW
QTY: 1.00
The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2
1/2" NST, 30-degree, chrome plated elbow.
PO00005156 - 2-1/2" NST PRESSURE VENTED CAP - DRIVER SIDE DISCHARGE #2
QTY: 1.00
A 2 1/2" NST, chrome plated, pressure vented cap shall be installed on driver's side # 2 discharge.
PO00005194 - TOP MOUNT SWING CONTROL HANDLE - DRIVER SIDE DISCHARGE #2
QTY: 1.00
The driver's side # 2 discharge valve shall be controlled by a locking push/pull swing handle located on
the top mount operator's panel.
PO00005223 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS- DRIVER SIDE
DISCHARGE #2
QTY: 1.00
The driver's side # 2 discharge shall be equipped with a 2.5", Innovative Controls pressure gauge.
The gauge shall have a rugged, corrosion free, stainless steel case and clear, scratch resistant, molded
crystals with captive, O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation, and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/- 1.5% full scale and
include a size appropriate phosphorous, bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished, chrome-plated, stainless steel bezel shall be provided to prevent corrosion and protect the
lens and gauge case.
The gauge shall have black graphics on a white background.
PO00012086 - OFFICER SIDE MAIN DISCHARGE #1
QTY: 1.00
A discharge shall be provided and located at the officer's side pump panel.
The officer's side discharges #1 shall terminate with NST threads, through the officer's side panel above
the main pump intake.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 67
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct
connect discharge valve flanges.
PO00005280 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE #1, SIDE MOUNT
QTY: 1.00
An Akron Brass, 3" Generation II, Swing-Out Valve shall be provided for the officer's side #1 discharge.
The valve shall have an all brass body with flow optimizing, stainless steel ball, and dual polymer seats.
PO00005292 - OS #1 DISCHARGE - 3" STRAIGHT NST & 30-DEGREE NST ELBOW
QTY: 1.00
The discharge valve shall be equipped with a straight, 3" NST adapter that shall be equipped with a 3"
NST, 30-degree, chrome plated elbow.
PO00005340 - TOP MOUNT SWING CONTROL HANDLE - OFFICER SIDE DISCHARGE #1
QTY: 1.00
The officer's side, # 1 discharge valve shall be controlled by a locking push/pull swing handle located on
the top mount, operator's panel.
PO00005370 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS- OFFICER SIDE
DISCHARGE #1
QTY: 1.00
The officer's side, # 1 discharge shall be equipped with a 2.5", Innovative Controls pressure gauge.
The gauge shall have a rugged, corrosion free, stainless steel case and clear, scratch resistant, molded
crystals with captive, O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/- 1.5% full scale and
include a size appropriate phosphorous, bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished, chrome-plated, stainless steel bezel shall be provided to prevent corrosion and protect the
lens and gauge case.
The gauge shall have black graphics on a white background.
PO00012103 - DRIVER SIDE HOSE BED DISCHARGE 2-1/2"
QTY: 1.00
A 2 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front
of the hose bed.
PO00005863 - DS HOSE BED DISCHARGE TERMINATE @ FLOOR LEVEL FRONT
QTY: 1.00
The rear hose bed discharge shall terminate just above the hosebed floor, in the driver side front of the
hose bed.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 68
PO00015487 - TOP MOUNT DRIVER SIDE HOSEBED DISCHARGE 1 - SWING HANDLE CONTROLS
QTY: 1.00
All top mount valves shall be controlled by a locking push/pull swing handle unless otherwise noted in the
individual discharge below.
PO00005867 - 2-1/2" NST MALE THREADS ON DRIVER SIDE HOSE BED DISCHARGE
QTY: 1.00
The driver side hose bed discharge pipe shall be equipped with a chrome 2 1/2" NSTM thread adapter.
PO00005871 - DS HOSE BED DISCHARGE, PLUMBING, 2-1/2" STAINLESS STEEL PIPING
QTY: 1.00
The driver side hose bed discharge shall be plumbed utilizing 2 1/2" schedule 10 stainless steel piping, 45
degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the
rear of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and
serviceability.
PO00005876 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE DRIVER SIDE HOSE BED
DISCHARGE
QTY: 1.00
An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side hose bed rear
discharge. The valve shall have an all brass body with flow optimizing stainless steel ball and dual
polymer seats.
PO00005886 - PUSH/PULL CONTROL FOR DRIVER SIDE HOSE BED DISCHARGE
QTY: 1.00
The driver side hose bed discharge valve shall be controlled by a push/pull handle located on the
operator's panel.
PO00005919 - 2-1/2" NST DRIVER SIDE HOSE BED DISCHARGE PRESSURE VENTED CAP
QTY: 1.00
A 2 1/2" NST chrome plated pressure vented cap shall be installed the driver's side hose bed discharge.
PO00005925 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS- DRIVER SIDE
HOSE BED DISCHARGE
QTY: 1.00
The driver's side hose bed discharge shall be equipped with a 2.5" Innovative Controls pressure gauge.
The gauge shall have a rugged corrosion free stainless steel case and clear scratch resistant molded
crystals with captive O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/ - 1.5% full scale and
include a size appropriate phosphorous bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished chrome-plated stainless steel bezel shall be provided to prevent corrosion and protect the lens
and gauge case.
The gauge shall have black graphics on a white background.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 69
PO00012108 - DECK GUN DISCHARGE
QTY: 1.00
A deck gun discharge shall be plumbed from the pump to an area on top of the vehicle.
The deck gun piping shall be firmly supported and braced.
PO00006023 - DECK GUN DISCHARGE TERMINATE @ CENTER OF DUNNAGE
QTY: 1.00
The deck gun discharge shall be located in the center of the dunnage area above the pump module.
A pedestal type, 1/4" steel plate support assembly shall be provided to stabilize deck gun plumbing below
deck gun mount flange.
PO00006030 - 3" NPT MALE THREADS ON DECK GUN DISCHARGE
QTY: 1.00
The deck gun discharge pipe shall terminate with 3" NPT threads.
PO00015531 - 3" TFT MANUAL EXTEND-A-GUN (12") PIPE - MODEL # XG12VL-**
QTY: 1.00
To improve the operation range of the deck gun, the discharge pipe shall be outfitted with a TFT (12")
Extend-A-Gun, part # XG12VL-**. The Extend-A-Gun shall be wired to the hazard light on the cab dash.
PO00006036 - DECK GUN DISCHARGE - OVA HEIGHT NOT EXCEED CRITICAL OVERALL HEIGHT
RESTRICTION
QTY: 1.00
Deck gun height will be limited to the critical overall apparatus height listed in the spec. To avoid
excessive travel heights the monitor will be positioned as low a practical while still allowing functionality of
water stream.
PO00006039 - DECK GUN DISCHARGE, PLUMBING, 3" STAINLESS STEEL PIPING
QTY: 1.00
The deck gun discharge shall be plumbed utilizing 3" schedule 10 stainless steel piping, 45 degree
elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the deck gun
location.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and
serviceability.
PO00006045 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE DECK GUN DISCHARGE
QTY: 1.00
An Akron Brass 3" Generation II Swing-Out Valve shall be provided for the deck gun discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00006058 - PUSH/PULL CONTROL FOR DECK GUN DISCHARGE
QTY: 1.00
The deck gun discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006091 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS- DECK GUN
DISCHARGE
QTY: 1.00
The deck gun discharge shall be equipped with a 2.5" diameter Innovative Controls pressure gauge.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 70
The gauge shall have a rugged corrosion free stainless steel case and clear scratch resistant molded
crystals with captive O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/ - 1.5% full scale and
include a size appropriate phosphorous bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished chrome-plated stainless steel bezel shall be provided to prevent corrosion and protect the lens
and gauge case.
The gauge shall have black graphics on a white background.
PO00012120 - LOWER SPEEDLAY
QTY: 1.00
lower speedlay shall be a transverse hose bed, which shall be designed as an integral part of the pump
module design, located forward of the pump above main inlet and side discharge connections.
Hose deployment shall be accomplished from either side of the apparatus.
The speedlay hose bed flooring shall be designed to be removable, constructed from brushed finish,
perforated aluminum material.
PO00012194 - STAINLESS STEEL SCUFF PLATES - LOWER SPEEDLAY
QTY: 1.00
The outer edge of the lower speedlay hosebed shall be trimmed stainless steel scuff plates. The scuff
plate will reduce the clear opening of the speedlay on each side.
PO00006879 - 1-1/2" NST CHICKSAN SWIVEL - LOWER SPEEDLAY
QTY: 1.00
The lower speedlay discharge shall terminate through the rear wall of the hosebed with a 1 1/2" NSTM
chicksan swivel adapter.
The hosebed rear wall shall be slotted to allow the swivel to through the wall, allowing the pre -connected
hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.
PO00012430 - TOP MOUNT LOWER SPEEDLAY DISCHARGE - SWING HANDLE CONTROLS
QTY: 1.00
The Speedlay # 1 discharge will be controlled at the top mount control panel with a lock ing swing handle.
PO00006890 - LOWER SPEEDLAY CAPACITY - 200 FEET OF 1-3/4" HOSE
QTY: 1.00
lower speedlay shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA
-1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.
The hose shall be loaded in a double stack configuration.
PO00006897 - LOWER SPEEDLAY, PLUMBING, 2" STAINLESS STEEL PIPING
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 71
The lower speedlay discharge shall be plumbed utilizing 2" schedule 10 stainless steel piping and/or
flexible hose, 45 degree elbows and a limited number of 90 degree sweep elbows in an assembly from
the pump to speedlay hosebed.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and
serviceability.
PO00006907 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE LOWER SPEEDLAY
QTY: 1.00
An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the lower speedlay discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00006925 - PUSH/PULL CONTROL LOWER SPEEDLAY
QTY: 1.00
The lower speedlay discharge valve shall be controlled by a push/pull handle located on the operator's
panel.
PO00006957 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS - LOWER
SPEEDLAY
QTY: 1.00
The lower speedlay discharge shall be equipped with a 2.5" Innovative Controls pressure gauge.
The gauge shall have a rugged corrosion free stainless steel case and clear scratch resistant molded
crystals with captive O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/ - 1.5% full scale and
include a size appropriate phosphorous bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished chrome-plated stainless steel bezel shall be provided to prevent corrosion and protect the lens
and gauge case.
The gauge shall have black graphics on a white background.
PO00012198 - STAINLESS STEEL SCUFF PLATES - UPPER SPEEDLAY
QTY: 1.00
The outer edge of the upper speedlay hosebed shall be trimmed stainless steel scuff plates. The scuff
plate will reduce the clear opening of the speedlay on each side.
PO00012432 - TOP MOUNT UPPER SPEEDLAY DISCHARGE - SWING HANDLE CONTROLS
QTY: 1.00
The Speedlay # 3 discharge will be controlled at the top mount control panel with a locking swing handle.
PO00007081 - 1-1/2" NST CHICKSAN SWIVEL - UPPER SPEEDLAY
QTY: 1.00
The upper speedlay discharge shall terminate through the rear wall of the hosebed with a 1 1/2" NSTM
chicksan swivel adapter.
The hosebed rear wall shall be slotted to allow the swivel to through the wall, allowing the pre-connected
hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 72
PO00007086 - UPPER SPEEDLAY CAPACITY - 200 FEET OF 1-3/4" HOSE
QTY: 1.00
upper speedlay shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA
-1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.
The hose shall be loaded in a double stack configuration.
PO00007091 - UPPER SPEEDLAY, PLUMBING, 2" STAINLESS STEEL PIPING
QTY: 1.00
The upper speedlay discharge shall be plumbed utilizing 2" schedule 10 stainless steel piping and/or
flexible hose, 45 degree elbows and a limited number of 90 degree sweep elbows in an assembly from
the pump to speedlay hosebed.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and
serviceability.
PO00007101 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE UPPER SPEEDLAY
QTY: 1.00
An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the upper speedlay discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00007114 - PUSH/PULL CONTROL UPPER SPEEDLAY
QTY: 1.00
The upper speedlay discharge valve shall be controlled by a push/pull handle located on the operator's
panel.
PO00007147 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS - UPPER
SPEEDLAY
QTY: 1.00
The upper speedlay discharge shall be equipped with a 2.5" Innovative Controls pressure gauge.
The gauge shall have a rugged corrosion free stainless steel case and clear scratch resistant molded
crystals with captive O-ring seals to ensure distortion free viewing and seal the gauge.
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy o f +/- 1.5% full scale and
include a size appropriate phosphorous bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished chrome-plated stainless steel bezel shall be provided to prevent corrosion and protect the lens
and gauge case.
The gauge shall have black graphics on a white background.
PO00000054 - WALKWAY ACCESS FOR SPEEDLAY #1
QTY: 1.00
The hose shall be capable of being reloaded from either side of the vehicle and from acce ss slots
provided on the front of the pump module while standing in the pump module walkway.
PO00000060 - WALKWAY ACCESS FOR SPEEDLAY #3
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 73
The hose shall be capable of being reloaded from either side of the vehicle and access slots provided on
the front of the pump module while standing in the pump module walkway.
PO00012200 - VINYL END FLAPS FOR SPEEDLAYS
QTY: 1.00
Vinyl coated polyester covers shall be provided on each side of the speed lays to retain hose in the speed
lays.
The covers shall be secured with expandable loops sewn into the covers and hooks on the apparatus.
PO00012202 - SPEEDLAY FLAP BLACK IN COLOR
QTY: 1.00
The speed lay end flap shall be black in color.
PO00012123 - WELL DISCHARGE - OFFICER SIDE 1-1/2"
QTY: 1.00
A 1-1/2" discharge shall be plumbed to the officer side lower pump panel.
PO00007224 - 1-1/2" NST STRAIGHT ADAPTER IN OFFICER SIDE WELL STORAGE
QTY: 1.00
The officer side storage well discharge shall terminate in the driver side storage well as directed by
engineering.
The discharge pipe shall be equipped with a chrome 1 1/2" NSTM straight adapter.
PO00007227 - OS WELL STORAGE, PLUMBING, 2" STAINLESS STEEL PIPING
QTY: 1.00
A discharge shall be plumbed utilizing 2" schedule 10 stainless steel piping and/or flexible hose in an
assembly from the pump to the officer side well storage of the vehicle.
PO00007229 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE WELL STORAGE
QTY: 1.00
An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the officer's side well storage
discharge.
The valve shall have an all brass body with flow optimizing stainless steel ball and dual polymer seats.
PO00007233 - PUSH/PULL CONTROL FOR OFFICER SIDE WELL STORAGE
QTY: 1.00
An officer side well storage discharge valve shall be controlled by a push/pull handle located on the
operator's panel.
PO00007247 - 1-1/2" NST OFFICER SIDE WELL STORAGE PRESSURE VENTED CAP
QTY: 1.00
A 1 1/2" NST chrome plated pressure vented cap shall be installed the officer side storage well discharge.
PO00007251 - INNOVATIVE CONTROLS LIQUID FILLED 2-1/2" PRESS GAUGE SS - OFFICER SIDE
WELL STORAGE
QTY: 1.00
The officer side storage well discharge shall be equipped with a 2.5" Innovative Controls pressure gauge.
The gauge shall have a rugged corrosion free stainless steel case and clear scratch resistant molded
crystals with captive O-ring seals to ensure distortion free viewing and seal the gauge.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 74
The gauge shall be filled with glycerin to dampen shock and vibration, lubricate the internal mechanisms,
prevent lens condensation and ensure proper operation from -40F to +160F.
The gauge shall exceed ANSI B40.1 Grade A requirements with an accuracy of +/ - 1.5% full scale and
include a size appropriate phosphorous bronze bourdon tube with a reinforced lap joint and large tube
base to increase the tube life and gauge accuracy.
A polished chrome-plated stainless steel bezel shall be provided to prevent corrosion and protect the
lens and gauge case.
The gauge shall have black graphics on a white background.
PO00012125 - BOOSTER REEL #1
QTY: 1.00
PO00015491 - BOOSTER REEL #1 DISCHARGE
QTY: 1.00
A 1 1/2" booster reel discharge shall be plumbed from the pump to the booster reel.
PO00015492 - BOOSTER REEL #1 DISCHARGE, PLUMBING, 1" HOSE
QTY: 1.00
The booster reel discharge shall be plumbed from the valve to the hose reel utilizing 1" hose. The end of
the hose connected to the hose reel shall be equipped with a swivel end for ease in hose replacement.
PO00007275 - 1-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE BOOSTER REEL
QTY: 1.00
A 1 1/2" Akron, #8800 series, full flow, stainless steel ball valve shall be provided for the booster reel #1
discharge.
PO00007282 - PUSH/PULL CONTROL FOR BOOSTER REEL #1
QTY: 1.00
The booster reel discharge valve shall be controlled by a push/pull handle located on the operator's
panel.
PO00007312 - BOOSTER REEL #1- PAINTED STEEL
QTY: 1.00
One (1) painted steel electric rewind booster reel shall be furnished.
The reel shall be equipped with a one(1) inch 90 full flow swivel joint and an adjustable brake for
freewheeling, drag or full lock operation.
Color shall be graphite.
PO00007314 - BOOSTER REEL #1 LOCATED ABOVE PUMP ENCLOSURE - DRIVER SIDE
QTY: 1.00
The booster reel #1 shall be mounted above the pump enclosure towards the driver's side of the unit.
PO00007320 - HOSE REEL #1 REWIND DRIVER'S SIDE PUMP PANEL
QTY: 1.00
Booster reel rewind shall be controlled by a pump panel mounted push button on the driver's side panel.
The booster reel circuit shall be equipped with a shielded toggle switch to act as a booster reel disconnect
to avoid accidental actuation of the booster reel rewind button.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 75
PO00007332 - BOOSTER REEL #1 HOSE, 200 FEET OF 1" HOSE
QTY: 1.00
Each booster reel shall be equipped with 200' of 1" booster hose in 100' sections.
Each length shall be fitted with NST couplings.
PO00007345 - TWO (2) BOOSTER REEL HOSE ROLLERS - DRIVER SIDE & OFFICER SIDE BLANK
OFF
QTY: 1.00
Two (2) horizontal hose rollers of polished stainless steel and guide spools shall be placed one (1) on
each side panel.
PO00010791 - PUMP INSTALLATION - CUSTOM
QTY: 1.00
PO00026334 - TOP MOUNT PUMP MODULE, PUMPER
QTY: 1.00
The pump module shall be a self-supported structure mounted independently from the body and chassis
cab.
The design must allow normal frame deflection without imposing stress on the pump module structu re or
side running boards.
The pump module shall be securely mounted to the chassis frame rails.
The pump module shall incorporate a formed structure on the top front to support the top mount control
panel and required mechanical control handles.
The valves shall be controlled by vertically operated swing handles.
Each handle shall be equipped with a twist-lock, easy-grip knob.
The valve control handles shall be mounted in-line.
Each valve control handle shall be connected to its respective valve via a control rod and a bell crank
mechanism, if needed.
Each control rod shall consist of a linkage with pressed in threaded adapters.
Each pressure gauge shall be located directly above its respective discharge control handle, and shall be
clearly marked by color coded name plates.
PO00000007 - PUMP MODULE - ALUMINUM CONSTRUCTION
QTY: 1.00
The pump module shall be a welded frame work utilizing structural aluminum components properly
braced to withstand the rigors of chassis frame flex.
PO00010828 - TOP MOUNT DUNNAGE AREA
QTY: 1.00
A dunnage area shall be provided above the pump enclosure, behind the top mount control panel, for
equipment mounting and storage. This area shall be furnished with a removable 3/16" tread plate floor
and shall be enclosed on the sides.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 76
NOTE: The size of this storage area may vary when top mounted crosslays, booster reel(s), etc., are
specified and located in this area.
PO00011445 - PUMP MODULE WALKWAY
QTY: 1.00
There shall be a transverse walkway located at the rear of the chassis cab, ahead of the pump module.
The walkway shall be constructed of 3/16" tread plate and shall be clear and unobstructed for through
traffic.
Folding step(s) shall be provided if necessary to maintain NFPA step heights. The folding steps shall
match all other steps on the body. If the step is not illuminated, step lighting shall be provided.
If steps adjacent to walkway (such as commercial chassis cab access steps) provide NFPA compliant
step height, folding steps shall not be provided.
A miscellaneous equipment storage compartment shall be provided at both sides of the walkway,
outboard of the chassis frame rails. A ROM compartment light shall be provided and acti vate with the
compartment door.
A vertically hinged, tread plate door with positive closure latch shall be provided on the outboard face of
each compartment.
Compartments shall be ventilated.
PO00011447 - WALKWAY WIDTH = 20"
QTY: 1.00
The pump house walkway shall be approximately 20" wide.
PO00011571 - RUNNING BOARD STEPS (NON-AERIALS)
QTY: 1.00
The driver and officer running board steps shall be fabricated of 3/16" tread plate plate.
The outside edge on each step shall be fabricated with a double break, return flange.
The steps shall be rigidly reinforced with a heavy duty support structure.
The running boards shall not form any part of the compartment design, and shall be bolted into place
with a minimum 1/2" clearance gap between any panel to facilitate water runoff.
PO00011573 - STORAGE WELL IN OFFICERS SIDE RUNNING BOARD
QTY: 1.00
A storage well, constructed of 1/8" aluminum, shall be recessed into the officer’s side runnin g board.
The storage well shall measure 9" deep x 9" wide x as long as possible between the running board
support members.
Drain holes shall be located in the bottom corners to allow water to drain from the storage well.
PO00011578 - TWO (2) VELCRO STRAPS ON OFFICER'S SIDE STORAGE WELL
QTY: 1.00
The officer's side running board hose well shall be furnished with Velcro straps to secure the hose stored
in the well.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 77
The straps shall be attached to each side of the hose well with stainless stee l footman loops.
PO00011591 - OFFICER'S SIDE WELL - GENERAL STORAGE
QTY: 1.00
The officer's side storage well shall be utilized for general storage of tools or equipment, the well shall be
a large as space allows.
PO00011608 - STORAGE WELL IN DRIVERS SIDE RUNNING BOARD
QTY: 1.00
A storage well, constructed of 1/8" aluminum, shall be recessed into the driver’s side running board.
The storage well shall measure 9" deep x 9" wide x as long as possible between the running board
support members.
Drain holes shall be located in the bottom corners to allow water to drain from the storage well.
PO00011613 - TWO (2) VELCRO STRAPS ON DRIVER'S SIDE STORAGE WELL
QTY: 1.00
The driver's side running board hose well shall be furnished with Velcro straps to secure the hose stored
in the well.
The straps shall be attached to each side of the hose well with stainless steel footman loops.
PO00011626 - DRIVER'S SIDE WELL - GENERAL STORAGE
QTY: 1.00
The driver's side storage well shall be utilized for general storage of tools or equipment, the well shall be
a large as space allows.
PO00000085 - TOP MOUNT PUMP PANEL - PUMPER
QTY: 1.00
The pump operator's control panel shall be located above the pump towards the rear of the transverse
walkway area with the operator facing the rear of the apparatus to operate the pump controls. The top
and side panels shall be completely removable and designed for easy access and servicing.
PO00000098 - TOP MOUNT GAUGE PANEL - 14 GAUGE BRUSHED STAINLESS STEEL
QTY: 1.00
The top operator's panel shall be fabricated from 14-gauge 304L stainless steel with a #4 (150/180 grit)
standard polished finish.
PO00000104 - TOP MOUNT SIDE PANELS - 14 GA. BRUSHED STAINLESS STEEL
QTY: 1.00
The left and right side pump panel shall be fabricated from 14-gauge 304L stainless steel with a #4
(150/180 grit) standard polished finish.
PO00000131 - HORIZONTALLY HINGED GAUGE PANEL - TOP MOUNT
QTY: 1.00
An angled, full width, horizontally hinged gauge access panel shall be provided at the top mount
operator's position. Chrome plated positive locks shall be provided along with chain holders to secure the
panel in the opened position.
PO00000138 - DRIVER'S SIDE VERTICALLY HINGED PUMP ACCESS DOOR - TOP MOUNT
QTY: 1.00
The driver side pump panel shall be split and vertically hinged to provide complete access to the pump
and plumbing on the driver side of the pump enclosure.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 78
The panels shall be equipped with stainless steel hinges and secured with push type locks to hold the
panels closed.
The drains located on the driver side panel shall be fastened to the lower panel, which shall be stationary.
PO00000139 - OFFICER'S SIDE VERTICALLY HINGED PUMP ACCESS DOOR - TOP MOUNT
QTY: 1.00
The officer's side pump panel shall be split and vertically hinged to provide complete access to the pump
and plumbing on the officer's side of the pump enclosure.
The panels shall be equipped with stainless steel hinges and secured with push type locks to hold the
panels closed.
The drains located on the officer's side panel shall be fastened to the lower panel, which shall be
stationary.
PO00010829 - PANEL FASTENERS
QTY: 1.00
Stainless steel machine screws and lock washers shall be used to hold these panels in position.
The panels shall be easily removable to provide complete access to the pump for major service.
PO00010830 - CAPS AND ADAPTERS SAFETY TETHER - BALL CHAIN
QTY: 1.00
All applicable discharge and suction caps, plugs and adapters shall be equipped with chrome plated ball
chain and secured to the vehicle.
PO00010832 - PUMP PANEL DISCHARGE/SUCTION TRIM PLATES, HIGH POLISHED
QTY: 1.00
A high polished trim plate shall be provided around each discharge port and suction inlet opening to allow
accessibility to the respective valve for service and repairs.
PO00010833 - DISCHARGE GAUGE TRIM BEZELS
QTY: 1.00
Each individual discharge gauge shall be installed into a decorative chrome-plated mounting bezel that
incorporates valve-identifying verbiage and color labels, unless manufacturer supplied otherwise.
PO00010834 - IDENTIFICATION PLATES
QTY: 1.00
Color coded identification tags shall be provided for all gauges, controls, connections, switches, inlets and
outlets.
PO00011788 - PUMP OPERATOR'S PANEL LIGHT SHIELD - TOP-MOUNT
QTY: 1.00
The pump operator’s panel shall be equipped with a light shield that shall be full width of the control
panel, and shall be positioned to cover the lights and prevent glare.
The light shield shall be equipped with the following lights:
PO00011738 - TECNIQ E18 LED LIGHTS - PANEL TOP-MOUNT
QTY: 1.00
• Six (6) Tecniq #E18 LED lights.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 79
One (1) light under the operator's panel light shield shall be actuated when fire pump is engaged in
addition to the pump engaged light.
PO00011741 - TECNIQ EON 3 LED LIGHTS - DRIVER SIDE TOP-MOUNT
QTY: 1.00
• Four (4) TecNiq Eon, 3-LED illumination lights mounted in horizontal stainless steel bezels and
mounting gaskets.
The lights shall be switched with the top mount panel lights.
PO00011786 - STEP LIGHTS FOR WALKWAY AREA - TOP MOUNT
QTY: 1.00
The top mount walkway shall be illuminated by the following lights:
PO00011785 - TECNIQ EON 3 LED LIGHTS - WALKWAY TOP-MOUNT
QTY: 1.00
• Four (4) TecNiq Eon, 3-LED illumination lights mounted in horizontal stainless steel bezels and
mounting gaskets.
The lights shall be controlled with the marker lights.
PO00011765 - TECNIQ EON 3 LED LIGHTS - OFFICER SIDE TOP-MOUNT
QTY: 1.00
• Four (4) TecNiq Eon, 3-LED illumination lights mounted in horizontal stainless steel bezels and
mounting gaskets.
The lights shall be switched with the top mount panel lights.
PO00011409 - PUMP PRESSURE & VACUUM TEST PORTS @ PANEL
QTY: 1.00
The pump panel shall be equipped with Vacuum Pressure test plugs to allow for test equipment to
monitor pump pressure and vacuum levels.
Chrome plugs and labels shall be provided for the test ports.
PO00025813 - PUMP THIRD PARTY CERTIFICATION - 750 GPM & UP
QTY: 1.00
The pump shall be third party performance tested to meet the requirements of NFPA -1901. There will be
no exceptions.
PO00023805 - TANK 1000 GAL POLY
QTY: 1.00
The water tank shall have a capacity of 1000 gallons, constructed from Poly material.
PO00027025 - WATER TANK CAPACITY
QTY: 1.00
Water tank capacity may be reduced due to weight restrictions.
PO00010843 - WATER TANK FILL TOWER POLY (TANK CAPACITY 1000-1250)
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 80
The tank shall have a combination vent and manual fill tower.
The fill tower shall be constructed of 1/2" PT3 polypropylene and shall be a minimum dimension of 12" x
12" outer perimeter.
The fill tower shall be blue in color indicating that it is a water-only fill tower.
The tower shall have a 1/4" thick removable polypropylene screen and a PT3 polypropylene hinged
cover.
The capacity of the tank shall be engraved on the top of the fill tower lid. Inside the fill tower there shall be
a combination vent/overflow pipe.
The vent overflow shall be a minimum of schedule 40 polypropylene pipe with a minimum I.D. of that is
designed to run through the tank, and shall be piped to discharge water behind the rear wheels as
required in NFPA 1901 so as to not interfere with rear tire traction.
PO00007665 - WATER TANK 4" OVERFLOW & VENT PIPE
QTY: 1.00
The fill tower shall be fitted with an integral 4" I.D. schedule 40 P.V.C. combination overflow/vent pipe
running from the fill tower through the tank to a 4" coupling flush mounted into the bottom of the tank to
allow water to overflow behind the chassis rear axle.
PO00007667 - WATER TANK 3" SUMP DRAIN
QTY: 1.00
A 3" drain plug shall be provided.
PO00007586 - IC, SL ULTRA-BRIGHT 10 LIGHT LED WATER TANK GAUGE - PUMP
QTY: 1.00
An Innovative Controls model #3030358, Ultra-Bright LED water level monitor shall be provided on the
pump operator's panel.
The level gauge shall contain ten (10) high intensity LEDs on the display in a vertical pattern allowing the
full, 3/4, 1/2, 1/4 and refill levels to be easily distinguished at a glance.
The display shall use a two-dimensional, two-element lens to refract the light from the LEDs to provide full
180 visibility for the level indications.
***SPECIAL: SP00036743 - IC, SL ULTRA-BRIGHT 10 LIGHT LED WATER TANK GAUGE - PUMP
PANEL OFFICER SIDE
QTY: 1.00
A secondary Innovative Controls model #3030358, Ultra-Bright LED water level monitor shall be
provided on the officer side pump panel.
The level gauge shall contain ten (10) high intensity LEDs on the display in a vertical pattern
allowing the full, 3/4, 1/2, 1/4 and refill levels to be easily distinguished at a glance.
The display shall use a two-dimensional, two-element lens to refract the light from the LEDs to
provide full 180 visibility for the level indications.
PO00023606 - IC SL ULTRA BRIGHT 10 LED REAR OF BODY
QTY: 1.00
An additional Innovative Controls model #3030358, Ultra-Bright LED water level monitor shall be provided
on the rear of the vehicle. The level gauge shall contain ten (10) high-intensity LEDs on the display in a
vertical pattern allowing the full, 3/4, 1/2, 1/4 and refill levels to be easily distinguished at a glance. The
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 81
display shall use a two-dimensional, two-element lens to refract the light from the LEDs to provide full
180° visibility for the level indications.
PO00007592 - IC WATER LEVEL - 1/4" NPT PRESS TRANSDUCER @ BOTTOM OF TANK
QTY: 1.00
The gauge shall use a pressure transducer #3030376-01 installed near the bottom of the water tank to
determine the correct volume in the tank.
PO00012226 - DIRECT TANK FILL, DS REAR, 2-1/2" FIREMENS FRIEND, 2-1/2" NST FITTING
QTY: 1.00
One (1) 2-1/2" NST direct tank fill shall be provided at the rear of the body, on the driver side, as low as
possible.
The direct tank fill shall be gated with a 2-1/2" Fireman's Friend (TTMA 6-bolt attachment pattern) check-
type fill valve.
The fill valve shall be capable of flowing at a rate in excess of 1,000 gallons per minute and will be of a
self deflecting design, requiring no additional diffusion device.
The fill valve shall be constructed of stainless steel, with a spring actuated piston-type sealing mechanism
to minimize seal wear and provide positive sealing of the valve.
The fill shall be equipped with a 30 degree elbow terminating with a 2-1/2" NST female swivel connection.
PO00023912 - APPARATUS BODY DESCRIPTION (CHALLENGER)
QTY: 1.00
The body side and compartment assemblies (will/shall) be designed and assembled to provide maximum
strength and durability under all operating conditions.
Special attention (will/shall) be taken to minimize corrosion on all fabricated parts and structural members
of the body. All bolt-on components (will/shall) be provided with a dissimilar metals isolation barrier to
prevent electric corrosion. The body design (will/shall) also incorporate removable panels to access rear
body mounts and fuel tank sending units.
The body (will/shall) be completely isolated from the cab and pump module structure.
PO00017089 - SUPER STRUCTURE FOR ALUMINUM BODIES
QTY: 1.00
The body super structure shall be an all welded configuration utilizing a combination of 6061- T6 thick
walled extrusion and 6061 structural channel.
This structure shall be designed to totally support the full length and width of the body and shall be
welded to the body side compartments by use of reinforcement plates to incorporate the compartments
into an integral part of the body weldment.
The super structure shall be bolted to the sides of the chassis frame at four (4) points.
STEPPING, STANDING, WALKING SURFACES
All stepping, standing, and walking surfaces on the body shall meet NFPA #1901 anti -slip standards.
tread plate utilized for stepping, standing, and walking surfaces shall be ALCOA No Slip type. Upon
request by the Purchaser, the manufacturer shall supply proof of compliance with this requirement.
PO00010863 - BODY SUB FRAME - ALUMINUM
QTY: 1.00
The body sub structure shall be an all welded configuration utilizing a combination of 3" x 1 -1/2" 6061-T6
thick walled structural tubing and 6061 structural channel.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 82
This structure shall be designed to totally support the full length and width of the b ody and shall be
welded to the body side compartments by use of reinforcement plates to incorporate the compartments
into an integral part of the body weldment.
The sub structure shall be bolted to the sides of the chassis frame at four (4) points.
The two (2) forward mounting points shall utilize a spring mount to help isolate the body from chassis
deflection.
This design shall provide storage capacity in each side compartment for a minimum of 500 lbs of
equipment, and a minimum of 1000 lbs of equipment in the rear step compartment.
PO00000628 - 100" WIDE BODY, 29"/14" DEEP SIDE COMPARTMENTS
QTY: 1.00
The fire body shall be 100" wide to provide the maximum amount of usable hose bed and compartment
space. The side body compartments shall be 29" deep in any full depth areas and 14" deep in any split
depth areas.
PO00018427 - CHALLENGER; WB FAMILY
QTY: 1.00
PO00009804 - SWEEP-OUT COMPARTMENTS (NON-AERIALS)
QTY: 1.00
Compartment floors shall be welded to the compartment walls and have a sweep out design for easy
cleaning.
Compartments with hinged doors shall have the door opening flanges bend down to produce the sweep -
out design.
Compartments with roll-up style doors shall have the external floor flange stepped down to produce a
sealing surface for the roll-up doors below the compartment floor.
The sweep out design shall also permit easy cleaning.
PO00016952 - BODY 3/16" ALUMINUM; CHALLENGER-FB/WB/LH/PRO
QTY: 1.00
All compartment panels and body side sheets shall be entirely 3/16" aluminum (5052 -H32). Each side
compartment assembly shall be both plug welded and stitch welded to ensure proper weld penetration on
all panels while avoiding the possible warping caused by a full seam weld. The side compartments shall
be welded on a fixture to ensure true body dimensions of all door openings. The side compartments and
body side panels are then set into a body squaring fixture where the super structure is installed and the
entire body is aligned to be completely symmetrical. The super structure is then welded to the
compartment side panels and reinforcement plates are inserted which allows the compartment panels to
become an integral component of the body support structure. A full seam weld shall not be used due to
the applied heat which could distort sheet metal and remove the protective coating from the perimeter of
the welded area. All seams shall be caulked prior to finish paint to ensure proper compartment seal.
PO00008936 - 64" WIDE FENDER - CUSTOM
QTY: 1.00
The body fender shall be 64" long, this shall allow for the suspension and related components to be
contained within the fender, preventing any intrusion into the body compartment storage area. Bodies
with notches in the front and/or rear compartment for suspension components are not acceptable. There
will be no exceptions.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 83
PO00009647 - STANDARD FENDER - NO STORAGE (COMMERCIAL)
QTY: 1.00
The standard body fender shall be provided, no special storage options have been specified for the
fender area.
PO00018443 - CHALLENGER WB STYLE BODIES
QTY: 1.00
PO00026493 - CHALLENGER, WB-FF-FS-R (1000 MAX COMBINED TANK CAPACITY)
QTY: 1.00
DRIVER'S SIDE COMPARTMENTATION
One (1) full height/full depth compartment, with a roll up door, shall be provided forward of the rear
wheels. Compartment dimensions 68" high x 49" wide x 29" deep, with a door opening of 64" high x 46"
wide.
One (1) high side compartment, with a roll up door, shall be provided above the rear
wheels. Compartment dimensions 34-5/8" high x 64" wide by 29" deep, with a door opening of 31-1/8"
high by 58" wide.
One (1) full height/full depth compartment, with a roll up door, shall be provided behind the rear
wheels. Compartment dimensions 68" high x 46" wide x 29" deep, with a door opening of 64" high x 46"
wide.
OFFICER'S SIDE COMPARTMENTATION
One (1) full height/split depth compartment, with a roll up door, shall be provided forward of the rear
wheels. Compartment dimensions 68" high x 49" wide x 29" deep in the lower 30" high area, 14" deep in
the upper 38" high area, with a door opening of 64" high x 46" wide.
One (1) high side compartment, with a roll up door, shall be provided above the rear
wheels. Compartment dimensions 34-5/8" high x 64" wide by 14" deep, with a door opening of 31-1/8"
high by 58" wide.
One (1) full height/split depth compartment, with a roll up door, shall be provided behind the rear
wheels. Compartment dimensions 68" high x 46" wide x 29" deep in the lower 30" high area, 14" deep in
the upper 38" high area, with a door opening of 64" high x 46" wide.
The water tank capacity will be reduced by the size of the foam tank added.
PO00019775 - ISOLATED REAR STEP COMPARTMENT - CHALLENGER WB
QTY: 1.00
One (1) rear step compartment 51" high x 42" wide x 29" deep in the lower portion and 12" deep in the
upper portion shall be provided with a door opening of 47 5/8" high x 42" wide.
PO00010936 - ROLL-UP DOORS
QTY: 1.00
Roll-up doors shall be provided on all compartments.
The roll-up doors shall be constructed from aluminum extruded slats which shall have a flexible seal
between each slat for proper sealing of the door.
A synthetic rubber seal shall be provided at each side, top and bottom edge of the door to prevent entry
of dirt into the compartment.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 84
The door shall be equipped with a lift bar style latch mechanism which shall latch at the bottom of the
door mounting extrusion.
The roll-up door assembly shall be furnished with a spring-loaded, counter balance assembly to assist in
door actuation.
All running board and high side compartments shall be equipped with roll-up doors.
PO00000264 - AMDOR BRAND ROLL-UP DOORS, SATIN
QTY: 1.00
The roll-up doors shall be Amdor brand roll-up doors. They should be equipped with a satin finish and a
dual durometer slat seal. The slats shall be made from a 1” double-wall aluminum and have a continuous
ball and socket hinge joint. The interior of the door shall be made of a smooth interior door curtain,
preventing equipment hang-ups. The bottom panel flange shall have a stainless steel lift bar latching
system. The lifting bar will have a cut out for easy access if using gloves.
PO00010862 - REAR BODY PANEL
QTY: 1.00
The rear body panel shall extend the full width between the body side compartments.
This panel shall be full height from the rear step to the hose bed floor.
No part of the rear panel shall be attached to the booster tank.
The rear body panel material shall be tread plate as standard.
If Chevron striping is specified for the rear of the body then smooth aluminum shall be utilized.
PO00027030 - BODY RUB RAILS, C-CHANNEL - ALUMINUM EXTRUSION
QTY: 1.00
Sacrificial extruded aluminum C-Channel style, rub rails shall be mounted at the base of the body,
extending outward from the body. The rub rails shall extend the full length of the main body.
PO00022571 - WHEEL WELL LINERS W/ FENDERETTE (ONE PIECE UNIT) - ALUMINUM
QTY: 1.00
Fully removable, one piece, bolt-in, aluminum rear wheel well liner and fenderette will be provided. The
wheel well liners will be natural metal finish and will protect the front and rear compartments and the main
body supports from damage. Wheel well liners and fenderettes which are welded in place or are only
partially removable shall not be considered. {No Exceptions}
PO00010934 - REAR MUD FLAPS
QTY: 1.00
Heavy duty mud flaps shall be provided behind the rear wheels.
PO00023896 - REAR STEP 8"D X 100"W - TAPERED CORNER
QTY: 1.00
The rear step (will/shall) be fabricated from 3/16" tread plate plate and (will/shall) be rigidly reinforced.
The rear step (will/shall) extend 8" past the rear edge of the body and (will/shall) be 100" wide with
tapered corners.
The rear edge of the step (will/shall) be designed to accommodate the rear clearance lights and recessed
for protection in the step reinforcement channel. The step tread plate overlay (will/shall) be bolted to the
step frame for ease of replacement.
PO00011558 - GRAB RAILS, HANSEN KNURLED STAINLESS STEEL TYPE
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 85
All hand rails shall be Hansen 1-1/4" outer diameter, knurled stainless steel, designed to meet NFPA
1901 requirements.
Molded gaskets shall be installed between the handrail stanchion castings and body surfaces to prevent
electrolytic reaction between dissimilar metals and to protect paint.
Grab rails shall be provided at the following specified locations.
Additional grab rails shall be provided adjacent to any additional steps specified to comply with NFPA
1901.
PO00011563 - TWO (2) VERTICAL RAILS ON REAR
QTY: 1.00
Two (2) vertical rails shall be mounted on the rear edge of the beavertails, one (1) each side.
PO00011564 - ONE (1) HANDRAIL, BELOW HOSE BED LEVEL
QTY: 1.00
One (1) horizontal, full width handrail shall be installed on the rear, below the level of the hose bed.
***SPECIAL: SP00040982 - HANDRAIL ABOVE DRIVER'S PUMP PANEL
QTY: 1.00
One (1) horizontal handrail shall be mounted above the driver's pump panel.
PO00011570 - HANDRAIL FORWARD OF PUMP HOUSE, EACH SIDE - TOP MOUNT
QTY: 1.00
Two (2) vertical handrails shall be mounted on each side of the forward pump house.
PO00011511 - INNOVATIVE CONTROLS LIGHTED STEP(S), BODY FRONT, DRIVER SIDE
QTY: 1.00
Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provid ed on
driver side body front to provide NFPA compliant access (maximum 18” height between steps) to an
upper horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body
compartments).
PO00011496 - INNOVATIVE CONTROLS LIGHTED FOLDING STEP(S), BODY REAR DRIVER SIDE
QTY: 1.00
Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provided on
driver side body rear to provide NFPA compliant access (maximum 18” height between steps) to an upper
horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body
compartments).
PO00011502 - NO FOLDING STEP(S), BODY REAR, OFFICER SIDE
QTY: 1.00
No folding steps shall be provided in this location.
PO00000317 - PAINTED REAR TOW EYES, BELOW BODY
QTY: 1.00
Two (2) painted tow eyes shall be furnished on the rear of the vehicle. The tow eyes shall be made from
plate steel and shall be bolted directly to the chassis frame rails with grade 8 bolts. The tow eyes will
extend below the body. The tow eyes shall be smooth and free from sharp edges. They will have a
minimum eyelet hole of 2-1/2". The tow eyes shall be painted.
PO00000218 - STANDARD BED - WIDE STYLE BED (94" WIDE)
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 86
The hose bed shall be located directly above the booster tank and be free from all sharp objects such as
bolts, nuts, and so on, in avoidance of damage to the fire hose. For added strength, the hose bed side
walls shall be approximately 3" thick, providing a mounting surface for devices such as warning and
scene lights. The inner hose bed side walls shall be brushed aluminum panels, which will help prevent
damage to painted surfaces when the hose is deployed. The front wall shall be flanged inward 2" with a 1"
downward return, providing additional rigidity to the front wall.
PO00000227 - CUSTOMER SPECIFIED HOSEBED CAPACITY - 1,500' X 5"; 400' X 3"; 200' X 2.5"
QTY: 1.00
The hose bed shall be designed with enough storage capacity to carry the following customer specified
hose load: Feet of 5" supply hose, Feet of 3" supply hose, and Feet of 2-1/2" attack hose.
PO00000228 - HOSEBED FLOORING - ALUMINUM SLATS
QTY: 1.00
Flooring is to be constructed from extruded aluminum and have proper spaces for ventilation purposes.
The flooring shall be smooth and free from sharp edges to avoid any hose damage. The hose bed floor
shall be removable, providng access to the inner body framework.
PO00000233 - TWO (2) - 1/4" ADJUSTABLE HOSEBED PARTITIONS
QTY: 1.00
Two (2) fully adjustable 1/4" aluminum hose bed partitions shall be provided. The partition shall be easily
adjustable by channels, located at the front and rear of the hose bed. The partition shall be removable for
access to the booster tank.
PO00000243 - HOSEBED COVER - VINYL WITH VELCRO
QTY: 1.00
A hose bed cover shall be provided and installed. The cover shall be made from heavy -duty vinyl coated
polyester fabric. The cover shall be sewn with ultraviolet resistant thread and have 2" wide nylon webbing
sewn around the perimeter to provide additional strength. The cover shall be secured to the top front body
flange with Velcro and quarter turn fasteners. The top side body flange should also be secured with
Velcro. A weighted flap shall be furnished on the rear of the cover with two (2) bungee cords.
PO00000254 - VINYL MATERIAL COLOR - BLACK
QTY: 1.00
The vinyl material shall be black in color.
PO00019805 - HOSE BED, CHALLENGER WB-FF-FS-10
QTY: 1.00
The hose bed shall be located directly above the booster tank and shall be free from all sharp objects
such as bolts, nuts, etc., to avoid damage to fire hose.
The hose bed will provide approximately 141 cubic feet of hose storage area for 2 ½” or larger fire hose,
exceeding NFPA 1901 minimum pumper hose storage requirements. The hose bed depth shall be 16".
The apparatus weight analysis will be based on 800' of 2 ½” hose unless otherwise specified. If the hose
load to be carried exceeds this minimum, the purchaser must advise the manufacturer prior to contract so
adequate chassis carrying capacity can be provided.
For added strength and rigidity, the hose bed side walls shall be (3) inches thick. The top edge of the front
wall shall be flanged inward two (2) inches and downward one (1) inch.
PO00023910 - SIDE OF WATER TANK LADDER STORAGE (OFFICER SIDE)
QTY: 1.00
The ground ladders (will/shall) be stored vertically next to the water tank, behind the side body
compartments and on the officer side of the apparatus.
To secure the ground ladders, a hinged rear access door (will/shall) be provided and tied into the "Do Not
Move Apparatus" warning system.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 87
PO00009012 - ALCO-LITE PEL-24 24' 2-SECTION EXTENSION LADDER (ALUMINUM)
QTY: 1.00
Alco-Lite model PEL-24; 24', aluminum, two (2) section extension ladder shall be prov ided.
PO00000375 - ALCO-LITE PRL-14 14' ROOF LADDER W/FOLDING HOOKS (ALUMINUM)
QTY: 1.00
Alco-Lite model PRL-14; 14', aluminum, straight roof ladder with folding hooks shall be provided.
PO00000381 - ALCO-LITE FL-10 10' FOLDING ATTIC LADDER (ALUMINUM)
QTY: 1.00
Alco-Lite model FL-10; 10', folding, aluminum, attic ladder shall be provided.
PO00012508 - PIKE POLE TUBE(S) - PUMPERS
QTY: 2.00
A pike pole tube(s) shall be provided.
Each holder shall be accessible from the rear of the apparatus.
Each pike pole holder shall be labeled to indicate the pike pole length.
PO00012516 - LOCATION PIKE POLE TUBE(S) - IN SUCTION HOSE COMPARTMENT
QTY: 2.00
The pike pole tube(s) shall be mounted in the suction hose storage compartment.
PO00000415 - SUCTION HOSE STORAGE BUILT INTO BODY BEHIND ROLLUP DOOR
QTY: 1.00
The suction hoses shall be located beneath the hose bed. There will be one (1) on the driver side and
one (1) on the officer side. The hose storage area shall be accessed from the rear of the apparatus.
Note: On bodies with roll up style doors, the storage area shall be behind the roll of the door and will not
affect usable compartment space. On bodies with hinged style doors, the storage area shall be in the top
corner of the compartment.
A vertically hinged smooth aluminum, finish painted to match the body, access d oor with thumb type
latches, shall be provided on the compartments. The door shall be provided with a door switch that ties
into the "Do Not Move Apparatus" warning system.
PO00000466 - TWO (2) 10' SECTIONS OF 6" MAXI-FLEX LIGHTWEIGHT SUCTION HOSE
QTY: 1.00
Two (2) 10' sections of six (6) inch Maxi-Flex (PVC) suction hose with lightweight hard coat couplings
shall be furnished. Couplings shall include a long handle with a female swivel on one end and a rocker
lug male on the other. All threads shall be six (6) inch N.S.T.
PO00019830 - 1/2 DEPTH ADJUSTABLE SHELF DESCRIPTION - RESCUE
QTY: 1.00
Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front
and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut
channel.
Half depth adjustable shelves shall be located as indicated at each compartment description.
PO00019871 - 1/2 DEPTH ADJUSTABLE SHELF(S) LOCATED R-1
QTY: 1.00
Located in the right side compartment #1
PO00019872 - 1/2 DEPTH ADJUSTABLE SHELF(S) LOCATED R-2
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 88
QTY: 1.00
Located in the right side compartment #2
PO00019873 - 1/2 DEPTH ADJUSTABLE SHELF(S) LOCATED R-3
QTY: 1.00
Located in the right side compartment #3
PO00019887 - ADJUSTABLE SHELF DESCRIPTION - RESCUE
QTY: 1.00
Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front
and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut
channel.
Adjustable shelves shall be located as indicated at each compartment description.
PO00019921 - ADJUSTABLE SHELF(S) LOCATED L-1
QTY: 2.00
Located in the left side compartment #1
PO00019923 - ADJUSTABLE SHELF(S) LOCATED L-3
QTY: 1.00
Located in the left side compartment #3
PO00019997 - 250#, FLOOR MOUNTED, ROLLOUT TRAY
QTY: 1.00
Slide out floor mount compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2"
upward bend at front and rear, and side supports attached to #250 rated slides. Slide out floor mount
shelving shall have gas shocks to hold the tray in and out.
Slide out floor mount shelving shall be as indicated at each compartment description.
PO00020029 - ROLLOUT TRAY, LOCATED L-3
QTY: 1.00
Located in the left side compartment #3
PO00020036 - ROLLOUT TRAY, LOCATED R-3
QTY: 1.00
Located in the right side compartment #3
PO00020176 - 600#, FLOOR MOUNTED, ROLLOUT TRAY 100%
QTY: 1.00
Floor mounted roll-out trays shall consist of heavy duty, roller bearing slide tracks with a load rating of 600
pounds, securely fastened to the compartment floor. The slide shall have a pull type latch to secure the
slide in the desired position. The slide tracks shall have a 100% extension.
The tray shall be fabricated from 3/16" brushed aluminum with a minimum 2" high flange on each of the
four sides to assist in retaining the equipment stored on each tray.
The 600 pound floor mounted roll out trays shall be as indicated at each compartment description.
PO00020209 - 600# SLIDEMASTER ROLLOUT TRAY, LOCATED REAR COMPARTMENT - 100%
QTY: 1.00
Located in the rear compartment
PO00020419 - SWING OUT TOOL BOARD, 3/16" ALUMINUM - RESCUE
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 89
QTY: 1.00
The tool boards shall be constructed of 3/16" smooth aluminum allowing mounting of equipment on the
interior and exterior of the tool board. The tool boards shall be installed with a Performance Advantage
Company PM-1000 Swing-Out Module Kit. Aluminum angles shall attach the hinges to Unistrut tracking to
allow depth adjustments. A heavy duty thumb latch shall be provided to secure the tool boards in the
closed position.
Swing out tool boards shall be as indicated at each compartment description.
PO00020454 - SWING OUT TOOL BOARD(S) LOCATED L-2
QTY: 2.00
in the left side compartment #2
PO00020533 - VERTICAL PULL OUT TOOL BOARD, 3/16" ALUMINUM, #250 CAPACITY - RESCUE
QTY: 1.00
VERTICAL PULL OUT TOOL BOARDS
Vertical pull out tool boards shall be provided. Each tool board shall be constructed of 3/16" smooth
aluminum allowing mounting of equipment on both sides of the tool boards. Each tool board shall be
attached to #250 rated slides, one at the top and one at the bottom of the tool board. 3/16" aluminum
angles shall attach the slides to tracking to allow horizontal adjustments. A gas shock shall be used to
secure the tool board in the stored and deployed position.
Vertical pull out tool boards shall be as indicated at each compartment description.
PO00020569 - VERTICAL PULL OUT TOOL BOARD(S) LOCATED L-3
QTY: 1.00
Located in the left side compartment #3
PO00020319 - FIXED VERTICAL DIVIDERS DESCRIPTION - RESCUE
QTY: 1.00
Full height, fixed mounted, vertical compartment dividers shall be fabricated from 3/16" brushed aluminum
material. The dividers shall extend the full depth of the specified compartment from the floor to the
compartment ceiling.
Full height, vertical dividers shall be as indicated at each compartment description.
PO00020324 - FIXED VERTICAL DIVIDER, LOCATED L-3
QTY: 1.00
Located in the left side compartment #3
PO00024164 - INSIDE/UNDERSIDE BODY -UNPAINTED
QTY: 1.00
The inside and underside areas of the complete body assembly shall be cleaned and un -painted prior to
the installation of the body on the chassis or torque box.
PO00010847 - GENERAL PAINT DESCRIPTION
QTY: 1.00
The apparatus body shall be painted with Sikkens paint product. The paint process shall meet or exceed
current state regulations concerning paint operations. Pollution control shall include measures to protect
the atmosphere, water, and soil. Contractor shall, upon demand, provide evidence that the manufacturing
facility is in compliance with State EPA rules and regulations.
The exterior shall have no mounted components prior to painting to assure full coverage of metal
treatments and paint to the exterior surfaces of the body. Any vertically or horizontally hinged smooth-
plate compartment doors shall be painted separately to assure proper paint coverage on body, door
jambs and door edges.
Paint process shall feature Sikkens high solid LV products and be performed in the following steps:
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 90
• Corrosion Prevention - all aluminum surfaces shall be pre-treated with the Alodine 5700 conversion
coating to provide superior corrosion resistance and excellent adhesion of the base coat.
• Sikkens Sealer/Primer LV - acrylic urethane sealer/primer shall be applied to guarantee excellent
gloss hold-out, chip resistance and a uniform base color.
• Sikkens High Solid LVBT650 (Base coat) - a lead-free, chromate-free high solid acrylic urethane
base coat shall be applied, providing excellent coverage and durability. A minimum of two (2) coats
shall be applied.
• Sikkens High Solid LVBT650 (Clear coat) - high solid LV clear coat shall be applied as the final step
in order to ensure full gloss and color retention and durability. A minimum of two (2) coats shall be
applied.
Any location where the material is penetrated after painting, for the purpose of mounting steps, hand rails,
doors, lights, or other specified components shall be treated at the point of penetration with a corrosion
inhibiting pre-treatment (ECK Corrosion Control). The pre-treatment shall be applied to the aluminum
sheet metal or aluminum extrusions in all locations where the aluminum has been penetrated. All
hardware used in mounting steps, hand rails, doors, lights, or other specified components shall be
individually treated with the corrosion inhibiting pre-treatment.
After the paint process is complete, the gloss rating of the unit shall be tested with a 20 degree gloss
meter. Coating thickness shall be measured with a digital MIL gauge and the orange peel with a digital
wave scan device.
PO00010848 - GENERAL PRIMER & PREP DESCRIPTION - PUMPER
QTY: 1.00
All exposed welds shall be ground smooth for final finishing of areas to be painted.
The compartments and doors are totally degreased and phosphatized.
After final body work is completed, grinding (36 and 80 grit), and finish sanding shall be used in
preparation for priming.
PO00010849 - GENERAL FINISH PAINT DESCRIPTION
QTY: 1.00
The body shall be finish sanded and prepared for final paint.
Upon completion of final preparation, the body shall be painted utilizing the highest quality, state of the
art, low V.O.C., polyurethane base paint.
Finish paint shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish.
PO00023017 - COMMERCIAL CAB PAINT FINISH - OTHER
QTY: 1.00
The chassis shall be painted and detailed as provided from the chassis OEM and shall meet their quality
guidelines.
PO00010850 - BODY BUFFING & FINISH - PUMPER
QTY: 1.00
The visable and exposed areas of the body shall be buffed and detailed.
PO00004548 - JOB COLOR COMPARTMENT INT W/SPATTER PAINT - PUMPER/TANKER
QTY: 1.00
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 91
The interior of the compartments shall be finish painted job color with a scuff resistant webbing type paint
of a contrasting color applied over the painted surfaces.
PO00022250 - PUMP PAINTED / UNPAINTED PLUMBING
QTY: 1.00
The pump shall be painted per the pump manufacturer’s standard. The stainless steel plumbing will
remain unpainted. The pump area interior will match the body underside finish as described elsewhere in
these specifications.
PO00004555 - SINGLE COLOR BODY PAINT SCHEME - PUMPER - TBD
QTY: 1.00
The body paint finish shall be Sikkens paint system in a single color to match customer furnished paint
codes and requirements.
PO00010855 - PINT OF TOUCH-UP PAINT
QTY: 1.00
One (1) pint of each exterior color paint for touch-up purposes shall be supplied when the apparatus is
delivered to the end user.
PO00010854 - FINALIZATION & DETAILING - PUMPER
QTY: 1.00
Prior to delivery the vehicle, the interior and exterior be cleaned and detailed.
The finalization process detailing shall include installation of NFPA required labels, checking fluid levels,
sealing and caulking required areas of the cab and body, rust proofing, paint touch-up, etc
PO00011790 - 4" SCOTCH-LITE STRIPE ON CAB AND BODY
QTY: 1.00
A four (4) inch high "Scotch-Lite" stripe shall be provided.
The stripe shall be applied on a minimum of 60 percent of each side of the unit, 60 percent on the rear of
the unit and 40 percent on the front of the unit.
The Scotch-Lite stripe layout shall be determined by the Fire Department.
PO00009525 - WHITE SCOTCH-LITE
QTY: 1.00
The Scotch-Lite shall be white in color.
PO00009536 - REAR CHEVRON STRIPING
QTY: 1.00
REAR CHEVRON STRIPING
PO00012449 - 50% VERTICAL SURFACE
QTY: 1.00
At least 50% of the rear facing vertical surface shall be covered with alternating strips of reflective
striping.
PO00009541 - 6" 50% REAR ORALITE CHEVRON STRIPING
QTY: 1.00
The striping shall be 6" Oralite reflective striping.
PO00026372 - RED & FLOURESCENT YELLOW GREEN ORALITE V98
QTY: 1.00
The Oralite V98 reflective tape shall be #12 red and #112 fluorescent yellow green in color.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 92
PO00026066 - MISCELLANEOUS EQUIPMENT
QTY: 1.00
The following equipment shall be mounted as specified or as loose equipment provided with the
completed apparatus at the time of delivery:
PO00011822 - ROAD SAFETY KITS
QTY: 1.00
A road safety kit shall be furnished with the following equipment:
• 2 1/2 lb. B-C fire extinguisher
• Triangle safety reflectors.
PO00000521 - TWO (2) ZICO #SAC-44 FOLDING WHEEL CHOCKS, (2) MTD DRIVER SIDE
QTY: 1.00
Two (2) ZICO #SAC-44 folding wheel chocks shall be mounted forward of the rear wheels on the driver
side below the side running board compartments.
PO00023664 - KME WARRANTY, STARTING ON IN-SERVICE DATE
QTY: 1.00
Warranty coverage by KME will begin when the customer places the unit in service. This date may not
exceed 60 days from the date of delivery to the customer.
The Customer must email kmeservice@kmefire.com within 60 days of delivery, or the warranty start date
will default to the original delivery date.
PO00026895 - GENERAL ONE (1) YEAR OR 24,000 MILES LIMITED WARRANTY
QTY: 1.00
Purchaser shall receive a General One (1) Year or 24,000 Miles limited warranty in accordance with, and
subject to, warranty certificate RFW0001. The warranty certificate is incorporated by reference into this
proposal, and included with this proposal or available upon request.
PO00026922 - REGULATED EMISSIONS SYSTEMS FIVE (5) YEARS OR CARB MILEAGE LIMITED
WARRANTY
QTY: 1.00
Purchaser shall receive a Regulated Emissions Systems Five (5) Years or CARB Mileage limited
warranty in accordance with, and subject to, warranty certificate RFW0140. The warranty certificate is
incorporated by reference into this proposal, and included with this proposal or available upon request.
PO00026923 - ELECTRICAL ONE (1) YEAR OR 18,000 MILES LIMITED WARRANTY
QTY: 1.00
Purchaser shall receive a Electrical One (1) Year or 18,000 Miles limited warranty in accordance with, and
subject to, warranty certificate RFW0201. The warranty certificate is incorporated by reference into this
proposal, and included with this proposal or available upon request.
PO00026956 - BODY STRUCTURE (ALUMINUM) TEN (10) YEARS OR 100,000 MILES LIMITED
WARRANTY
QTY: 1.00
Purchaser shall receive a Body Structure (Aluminum) Ten (10) Years or 100,000 Miles limited warranty in
accordance with, and subject to, warranty certificate RFW0502. The warranty certificate is incorporated
by reference into this proposal, and included with this proposal or available upon request.
PO00026977 - PAINT AND FINISH (EXTERIOR CLEAR COATED) TEN (10) YEARS LIMITED
WARRANTY
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 93
QTY: 1.00
Purchaser shall receive a Paint and Finish (Exterior Clear coated) Ten (10) Years limited warranty in
accordance with, and subject to, warranty certificate RFW0710. The warranty certificate is incorporated
by reference into this proposal, and included with this proposal or available upon request.
PO00026981 - PLUMBING AND PIPING (STAINLESS STEEL) TEN (10) YEARS OR 100,000 MILES
LIMITED WARRANTY
QTY: 1.00
Purchaser shall receive a Plumbing and Piping (Stainless Steel) Ten (10) Years or 100,000 Miles limited
warranty in accordance with, and subject to, warranty certificate RFW0800. The warranty certificate i s
incorporated by reference into this proposal, and included with this proposal or available upon request.
PO00022701 - PAINT FINISH WARRANTY, TEN (10) YEAR
QTY: 1.00
The proposed paint finish will be warranted for a period of ten (10) years from the dat e of acceptance of
the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty
document.
PO00022702 - 5 YEAR LETTERING WARRANTY
QTY: 1.00
The apparatus manufacturer will provide a five (5) year warranty against defects in material and
workmanship for all graphics processes. Any valid claims must be made in writing within 15 days of the
determination of any defects to the manufacturer's fire apparatus. The manufacturer will at its option
make any necessary repairs either at a local authorized service center or at the factory if required. The
manufacturer will make the final decision as to where the repairs are to be made and any transportation
cost is the owner's responsibility. The manufacturer will at its option, repair or replace any verified defects
in workmanship or materials at no cost to the owner provided all the requirements of this warranty have
been met.
The manufacturer will not be liable to the original purchaser or anyone else for consequential, incidental,
special or direct damages, including, but not limited to, any claims for loss of profits, downtime, loss of
use or inconvenience. THE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OF IMPLIED,
AND SPECIFICALLY, DISCLAIMS ANY IMPLIED WARRANTY INCLUDING THE WARRANTY OF
MERCHANTABILITY.
The manufacturer continually strives to improve its products and therefore, reserves the right to make
improvements or changes without incurring any obligations to make such changes or additions to
equipment previously sold.
PO00022703 - 1 YEAR BRIGHTWORK WARRANTY
QTY: 1.00
KME Fire Apparatus (KME) warrants all bright finish components used in the construction of KME Fire
Apparatus against defects and workmanship provided the apparatus is used in a normal and reasonable
manner. This warranty is extended only to the original user-purchaser for a period of one (1) year from
the date of delivery/acceptance to the original user-purchaser, whichever occurs first.
The expressed warranty excludes corrosion or degradation of bright finished components caused by
damage to the component.
PO00022981 - 10 YEAR STAINLESS STEEL PIPING WARRANTY
QTY: 1.00
The proposed stainless steel plumbing will be warranted for a period of ten (10) years from the date of
acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the
specific warranty document.
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 94
PO00022973 - LIFETIME POLY TANK WARRANTY - ALL TANKS
QTY: 1.00
The proposed water tank will be warranted by the water tank manufacturer for the "Lifetime" of the unit. A
copy of the manufacturer's warranty will be supplied to define additional details of the warranty provisions.
PO00022734 - HALE FIRE PUMP LIMITED STANDARD WARRANTY
QTY: 1.00
Hale Products, Incorporated ("Hale") hereby warrants to the original buyer that products manufactured by
Hale shall be free of defects in material and workmanship for a period of five (5) years from the date
product is first placed into service or five and one-half (5 1/2) years from date of shipment by Hale,
whichever period shall be first to expire. Within this warranty period, Hale will cover parts and labor for the
first two (2) years and parts only for years three (3) through five (5).
PO00022989 - CLASS 1 - PRODUCT WARRANTY
QTY: 1.00
Class 1 warrants that any equipment of our own manufacture (or manufactured for us pursuant to our
specifications) found to have defects in material or workmanship during normal use and service, will be
repaired or replaced (at our opinion) free of charge, provided that written notice of such defect is received
by us within two (2) years, (three 3 years on liquid filled gauges) after initial shipment.
PO00022988 - AKRON - 5 YEAR LIMITED WARRANTY
QTY: 1.00
The limited warranty set forth here against defective materials or workmanship for a period of five (5)
years will be given by Akron Brass Co. with respect to Akron Brass Co. products purchased and used in
the United States and Canada respectively. All Akron valves are warranted for 10 years.
PO00022761 - AKRON HEAVY DUTY VALVE - 10 YEAR WARRANTY
QTY: 1.00
Akron Brass warrants Heavy Duty Swing-Out Valves for a period of ten (10) years after purchase against
defects in material or workmanship. Akron Brass shall repair or replace any Heavy Duty S wing Out Valve
which fails to satisfy this warranty.
PO00022983 - CLASS 1 - ELECTRICAL PRODUCT WARRANTY - 2 YEAR
QTY: 1.00
Class 1 warrants that any equipment of our own manufacture (or manufactured for us
pursuant to our specifications) found to have defects in material or workmanship during normal use and
service, will be repaired or replaced (at our option) free of charge, provided that written notice of such
defect is received by us within two years (three for liquid-filled gauges) after initial shipment.
All equipment requiring repair or replacement under this warranty will be returned prepaid to Class 1.
Such returned equipment will be examined by us and, if found to be defective as a result of materials
failure or workmanship, will be repaired or replaced at no charge.
PO00010937 - CORROSION TREATMENT
QTY: 1.00
Upon apparatus completion, underside of the apparatus, from the pump enclosure-back, shall have anti
corrosion film applied to help inhibit rust and the corrosion process. The semi-firm wax film shall be
applied by air spray method. The film shall be applied as a minimum to the following areas: body
substructure, underside of all body compartments, running board supports and rear step supports. No film
shall be applied directly to the exhaust system or wheel wells.
NOTE: The film shall remain semi-firm to promote self-sealing. The film may leave a light tinted color to
those areas treated.
PO00024906 - ADDITIONAL ITEMS SHIPPED WITH VEHICLE
GSO# 11694-95
Specification: QP Build Verification
Contract Administrator: Jared Eickhoff
GSO# 11694-95 July 13, 2022 Page 95
QTY: 1.00
• 1 - Bag of assorted stainless steel nuts and bolts
PO00024715 - VEHICLE CLASS TIER 0
QTY: 1.00
Change
Item #
Add/Delete/
Clarification Part # Description
Contract Change
To Pay or (To
Receive)
Change
Accepted?
$31,108
1 Clarification PO00011120 The inspection trips shall be removed from the spec. $0.00 Yes
2 Clarification The paint code for the primary color shall be RED FLNA 32046. A paint sample shall be sent to the customer for approval. $0.00 Yes
3 Clarification The front tire size shall be changed to 385/65R22.5 X Multi HL Z tires. $360.00 Yes
4 Clarification The tire pressure monitor LEDs shall be shipped loose. $0.00 Yes
5 Clarification The front brakes shall be upgraded to EX-225 17" disc brakes. $770.00 Yes
6 Clarification The wheelbase shall be updated to 207". *This is dependend on pumphouse size and may have to increase due to options
below in this letter. $0.00 Yes
7 Clarification The rear frame overhang measurement shall be updated to match the new configuration with options as agreed to in this
letter. $0.00 Yes
8 Clarification The front bumper extension shall be increased to 24". $415.00 Yes
9 Clarification The front bumper center well shall have a treadplate cover. $615.00 Yes
10
Clarification The front bumper center well shall have a notch on the officer's side to accommodate the 1.5" front discharge. $530.00 No
11 Clarification Provide a Q2B pedestal mounted on the driver side of the front bumper. $2,470.00 Yes
12 Clarification The auxiliary manual cab jack shall be located within the pumphouse on the officer side. $0.00 Yes
13 Clarification The FC-94 cab shall have power windows. $0.00 Yes
14 Clarification The driver seat shall have an electric seat base. The seat shall be an H.O. Bostrom 400 Series Firefighter Sierra model
seat. The seat shall feature eight-way electric positioning. $730.00 Yes
15 Clarification Add two (2) Bostrom rear facing SCBA seats with Secure All SCBA brackets. The seats shall be ABTS. $2,375.00 Yes
16 Clarification The exterior cab door handles shall be CHROME finished. (CAB DOOR HARDWARE - 1103-004) $695.00 Yes
17 Clarification The alternator shall be upgraded to a 320Amp. The charging system shall include a 320 amp Leece-Neville 12 volt
alternator. The alternator shall include a self-exciting integral regulator. $455.00 Yes
October 10, 2022
Precon Letter RevA
Dealership: SAFE Industries
GSO# 11694-95
Subtotal
The following is a list of changes, additions, and clarifications discussed during the pre-construction meeting on October 10, 2022 held at KME headquarters in Nesquehoning, PA regarding GSO #
11694-95
In some cases the items contained within alter your original purchase specification and/or price. Please carefully review this list and return a signed copy of this letter by the date listed below.
Delays beyond this timeframe may alter KME’s ability to deliver your apparatus to contract requirements, may necessitate price increases to the options, or limit our ability to provide some or all of
the changes.
Page 1 of 5
Change
Item #
Add/Delete/
Clarification Part # Description
Contract Change
To Pay or (To
Receive)
Change
Accepted?
18 Clarification
A Kussmaul Pump 12V air compressor shall be supplied. The air compressor shall be installed under the dashboard on the
right-hand side, forward of the officer’s seating position. The air compressor shall be plumbed to the air brake system to
maintain air pressure. The air compressor shall include an auto drain as an extra precaution to prevent moisture from
entering the air system. The automatic moisture drain shall be plumbed into the system between the auxiliary air
compressor pump and the air tanks.
$570.00 Yes
19 Clarification All C6 warning lights shall be changed to 600 series warning lights. $0.00 Yes
20 Clarification The intersection warning lights shall be relocated to the sides of the chassis front bumper. $0.00 Yes
21 Clarification A DEF fill door shall be provided through the driver side of the cab. $95.00 Yes
22 Clarification
The cab shall include a 12 volt cigarette lighter type receptacle in the cab dash to provide a power source for 12 volt
electrical equipment. The cab shall also include one (1) Blue Sea dual universal serial bus (USB) charging receptacle in the
cab dash switch panel to provide a power source for USB chargeable electrical equipment. The USB port shall be capable
of a 5 Volt-4.8 amp total output. The receptacles shall be wired battery direct.
$175.00 Yes
23 Clarification The front of the cab shall include one (1) HiViz model FireTech FT-B-72 LED scene light installed on the brow of the cab.
The housing shall be powder coated black.. There shall be controls for this front scene light provided on the dash. $5,445.00 Yes
24 Clarification Provide lug and hub trim package for the front and rear wheels. $415.00 Yes
25 Clarification A rear scene light switch will not be provided on the rear of the body. $0.00 Yes
26 Clarification A hosebed worklight switch shall be provided in a recessed pocket on the driver side rear of the body. $0.00 Yes
27
Clarification The rear cab scene lights and switching shall be deleted. ($990.00) No
28 Clarification Provide switches on the pump panel for driver side, officer side, and rear scene lighting. These shall be located adjacent to
the already specified telescoping light control switches. $150.00 Yes
29 Clarification All C6 warning lights shall be changed to 600 series lights. All C9 warning lights shall be changed to 900 series lights. All
warning light lenses shall be clear. $0.00 Yes
30
Clarification The blue sea fuse block specified for the R3 compartment shall be removed. ($345.00) No
31 Clarification PO00003419 Upgrade from single compartment lighting to dual compartment lighting. $2,130.00 Yes
32 Clarification The Whelen C6 scene lights on the rear, driver, and officer sides of the body shall be changed to HiViz guardian scene
lights. $1,045.00 Yes
33 Clarification Provide two alloy pump anodes for the Hale QMAX pump. $575.00
Yes
34 Clarification Both auxiliary inlets shall be provided rearward of the main pump inlet. Top mount controls shall be provided. $0.00 Yes
35 Clarification PO00005093 The driver side #1 discharge shall be a top mount locking swing control. This valve control will NOT be electric. ($2,790.00) Yes
36 Clarification Provide a 3"x 5" Storz 30 degree elbow adapter on the officer side #1 discharge. $650.00 Yes
37 Clarification Delete the cap from the driver side hosebed discharge. ($30.00) Yes
38 Clarification The deck gun discharge shall terminate at the top of the pump panel gauge panel header, approximately centered as the
plumbing configuration allows . This is to free up the dunnage area. $0.00 Yes
Page 2 of 5
Change
Item #
Add/Delete/
Clarification Part # Description
Contract Change
To Pay or (To
Receive)
Change
Accepted?
39 Clarification References to push/pull control shall be changed to locking swing handle controls. $0.00 Yes
40 Clarification The lower speedlay and upper speedlays shall be provided with poly trays for loading and unloading hose. Accepting this
option will increase the pumhouse width, wheelbase, and overall length of the apparatus. $2,010.00 No
41 Clarification The specified 2.5" driver side discharge shall be changed to a 2.5" officer side discharge. $0.00 Yes
42 Clarification PO00012123 The specified well discharge on the officer side shall be deleted. ($2,290.00) Yes
43 Clarification The booster reel shall be relocated to the officer side. A booster reel rewind switch shall be provided on both sides of the
pump house. $0.00 Yes
44 Clarification Delete the specified booster hose. The reel will be provided and the customer will furnish their own hose. ($1,065.00) Yes
45 Clarification The running board storage hose wells shall be changed to floating style hose wells. $0.00 Yes
46 Clarification The running board storage velcro straps shall be upgraded to airline buckle straps. $130.00 Yes
47 Clarification PO00000104 The driver and officer side pump panel sheets shall be painted BLACK Line-X. If this item is denied then the currently
specified stainless shall be provided. $3,185.00 No
48 Clarification PO00000098 The pump operators gauge panel shall be painted BLACK Line-X. If this item is denied then the currently specified
stainless shall be provided.
$2,075.00 Yes
49 Clarification A 25 gallon foam tank shall be provided. $1,260.00 Yes
50 Clarification An IC-SL ultra bright foam tank level gauge shall be provided on the pump operator gauge panel. $750.00 Yes
51 Clarification SP00036743 The officer side pump panel water level gauge shall be deleted. ($505.00) Yes
52 Clarification PO00023606 The rear of body IC-SL water level gauge shall be deleted. ($402.00) Yes
53 Clarification
Future dump provisions shall be provided in the water tank and switch wiring shall be provided within the rear step
compartment. Wiring shall be provided in the cab dash and within the rear step compartment so that switches can be
added in those locations.
$655.00 Yes
54 Clarification PO00012226 The direct tank fill shall be changed to a Akron 3" valve with 2.5" fitting. The direct tank fill will be located on the officer side
rear of the body. $755.00 Yes
55 Clarification PO00012226 Clean up the (will/shall) verbiage. Replace will/shall with shall. $0.00 Yes
56 Clarification
Provide fender storage compartments with painted doors. Driver side forward fender storage for triple cylinder, driver side
rearward fender storage for double cylinder (separate from cast products fuel fill), officer side forward fender storage with
slide-out dry hopper, and officer side rearward fender storage for triple cylinder.
$6,020.00 Yes
57 Clarification PO00022571 The rear body wheel well liners shall be RUBBER. $285.00 Yes
58 Clarification PO00023896 The rear step shall be 12" long with an aggressive taper. This will increase the OAL of the apparatus. $0.00 Yes
Page 3 of 5
Change
Item #
Add/Delete/
Clarification Part # Description
Contract Change
To Pay or (To
Receive)
Change
Accepted?
59 Clarification PO00011563 The two (2) specified vertical handrails for the rear of the body shall be located as far outboard as possible. $0.00 Yes
60 Clarification The pumphouse walkway entrance hand rails shall be provided on the outboard face of the pumphouse side sheets. This is
so that the walkway width is not affected. $0.00 Yes
61 Clarification Add folding steps to the officer side front of the body. $345.00 Yes
62 Clarification The Alco-Lite ladder shall be changed to Duo-Safety ladders. $40.00 Yes
63 Clarification A backboard slot shall be provided within the ladder storage compartment. $885.00 Yes
64 Clarification The 14' roof ladder shall be provided with dual sided roof hooks. $0.00 Yes
65 Clarification Compartment vents shall be provided for the hard suction storage compartments. $0.00 Yes
66 Clarification PO00019872 Delete the one (1) specified half depth shelf from the R2 compartment. ($435.00) Yes
67 Clarification The vertical divider in the L3 compartment shall be provided 16" rearward of the forward clear door opening. $0.00 Yes
68 Clarification PO00020029 Delete the 250lb roll-out tray from the floor of the L3 compartment. ($855.00) Yes
69 Clarification Provide two (2) adjustable shelves (adding one) located to the rear of the vertical dividier. $565.00 Yes
70 Clarification The adjustable vertical pull out toolboard shall be located in the L3 compartment forward of the vertical divider. $0.00 Yes
71 Clarification Delete the two (2) swing out tool boards from the L2 compartment. ($2,580.00) Yes
72 Clarification Provide one (1) roll-out drop down tray in the L2 compartment. $1,595.00 Yes
73 Clarification Upgrade the 250# floor mounted roll-out tray in R3 to a 600# roll-out tray. $765.00 Yes
74 Clarification PO00004548 The body compartment interior paint shall be changed to GRAY mulit-tone. $390.00 Yes
75 Clarification PO00011790 The 4" Scotchlite stripe shall be increased to a 6" black Scotchlite stripe. $90.00 Yes
76 Clarification 1/2" silver leaf accent stripes shall be provided on the top and bottom of the black Scotchlite main stripe. No space will be
provided between the main stripe and the silver leaf accent. $1,720.00 Yes
77 Clarification The Scotchlite stripe shall have a Z affect on the L1 and R1 compartment doors. $315.00 Yes
78 The specified Hale QMAX-150 shall be upgraded to a Hale QMAX-175 (1750GPM) single stage pump. $4,800.00 No
79 Future provisions for a foam system shall be provided to the following discharges: Front bumper discharge, upper
speedlay, and lower speedlay. $3,285.00 Yes
Customer Contract
Change To Pay or (To
Receive)
$31,108
Delivery days Commitment from Contract Signing
Letter Totals
Page 4 of 5
Change
Item #
Add/Delete/
Clarification Part # Description
Contract Change
To Pay or (To
Receive)
Change
Accepted?
-
Total new contractual delivery days commitment -
10/10/2022
10/20/2022
Customer Signature _________________________Customer Name____________________________________ Date _____________
Dealer Signature Dealer Name William Gray Date 10-14-2022
KME Signature _____________________________ Name Jared Eickhoff___________________________ Date ______3/6/2020_______
Upon receipt of a signed copy of these documents, the below changes and clarifications will be amended to the build specification
for your apparatus and a copy will be provided for your review and use for future inspections of the apparatus.
# days added to delivery commitment for this pre-construction letter due to scope and/or quantity of modifications made on this
letter.
Date sent to Customer/Dealer for Signature
Date Letter needs to be returned (10 days)
Page 5 of 5
Source: City of Walhalla website. First collected Oct 24, 2026.