BOA-26-15, 6265 Fish Rd. (County) - Memo
City of Sumter · Sumter County · Other
Open the original document More from City of Sumter
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Sumter City-County
Planning Department
DERON L. MCCORMICK HELEN M. ROODMAN GARY M. MIXON
CITY MANAGER PLANNING DIRECTOR COUNTY ADMINISTRATOR
12 WEST LIBERTY STREET • PO BOX 1449 • SUMTER, SC 29151
OFFICE: (803) 774-1660 • FAX (803) 774-1687
Memorandum
To: Sumter City-County Zoning Board of Appeals
From: Jeff Derwort, AICP (Zoning Administrator)
Date: June 26, 2026
Subject: BOA-26-15, 6265 Fish Rd. (County)
At the June 10, 2026 Zoning Board of Appeals (BOA) meeting, a decision on Case# BOA -25-15
was deferred to the July 8, 2026 BOA meeting in order for the applicant to address the following
BOA requests:
1. Attempt to get the manufactured home installer or the company responsible for the
installation of the manufactured home on the property to be present at the next BOA
meeting (July 8, 2026) to address questions about the placement of the dwelling on the
property.
2. Obtain a survey of the property showing the following items:
• Property lines
• Current mobile home footprint
• Footprints of other structures on the property
• Zoning setback lines
• Septic tank location and drainfield area
Staff has received updated information from the applicant with respect to the requests above . Staff
has also discovered new information related to t he case upon further research of Planning
Department record archives. The purpose of this memo is to summarize this information in order
to aid the Board in making a decision concerning this case.
Summary of New Information
1. Based on detailed research, the property is part of a larger area that was rezoned from
Agricultural Conservation (AC) to General Residential (GR) by Sumter County Council on
April 25, 2000 under Case# RZ -00-06. No other rezoning case records have been
located concerning the property showing a rezoning of this area back to the AC
district. As such, it appears that zoning map records were never updated to reflect the
zoning change under Case# RZ-00-06 and that GR zoning, not AC zoning, is applicable to
the property. See attached Exhibit 1 - Case# RZ-00-06 documentation.
Note: The discovered zoning discrepancy does not resolve the side setback issue created by
the current placement of the manufactured home on the property. However, it does reduce
the amount of side setback required and removes the requirement for the long dimension
of a manufactured home to be parallel to the road.
2. The lot addressed as 6265 Fish Rd., and further identified as TMS# 093 -00-02-022, was
originally established via plat prepared by Nesbitt Surveying Co., Inc. and recorded in Plat
Book 2000, Page 510 at the Sumter County Register of Deeds. The lot is shown as being
0.5-acres in size . The plat itself lists GR zoning setback requirements at Front (35’), Side
(8’), and Rear (20’). See attached Exhibit 2 – PB2000, PG150.
3. A manufactured home was originally approved for placement on the property under
Building Permit# 03 -05612. Permit records indicate that a new septic tank was being
installed with the placement under DHEC Septic Permit# 2003-100003. A hard copy of the
actual septic permit was not located.
4. The property at 6265 Fish Rd. was pu rchased by Glenn Collier (applicant’s husband) on
September 3, 2013. The purchase also included the manufactured home placed on the
property on or around December 2003.
5. The applicant lived in the manufactured home initially placed on or around December 2003
until it was destroyed by fire on March 3, 2025. See Exhibit 3 – Fire Report.
6. The applicant received a permit to install a new mobile home on the property under
Building Permit# 2025-01738 on April 28, 2025. Records indicate the manufactured home
placement passed Building Department final inspections.
7. Shakeema Anderson, owner of the adjacent property , commissioned a survey of the shared
property line boundary between her and the applicant. This survey indicates that the new
manufactured home placed on the property at 6265 Fish Rd. under Building Permit# 2025 -
01738 is 3.3 ft. from the side property line, in violation of applicable side setback
requirements. See Exhibit 4 – Anderson Survey.
8. Pursuant to the BOAs request for additional information, the applicant commissioned a
survey of the entire property at 6265 Fish Rd. The results of this survey support the
findings of the survey commissioned by Shakeema An derson. This survey also indicates
that the manufactured home on the property is 3.3 ft. from the side property line, in
violation of applicable side setback requirements. See Exhibit 5 – Collier Survey.
9. Pursuant to the BOAs request for additional information, the applicant obtained the services
of a septic tank consult to assist in locating the position of the septic tank and the drainfield
areas on the property. Due to timing of site visits, the location of the septic tank and
drainfield area could not be shown on the formal survey. Staff has created a location graphic
showing the approximate location of the septic tank and drainfield area based on site visit
documentation. See Exhibit 6 – Septic Tank & Drainfield Locations.
10. Topography on the property slopes downward from south to north by +/- 5 ft. from si de
property line to side property according to available GIS topographic data. A noticeable +/ -
2-3 grade difference was observed along the boundary between the subject property (6265
Fish Rd.) and the adjacent property to the south (6255 Fish Rd.). See Exhibit 7 – Site
Topography.
11. Additional site photos have been obtained for BOA consideration of this case. See attached
Exhibit 8 – Site Photos.
Key New Findings
1. The property is within the GR zoning district, not the AC district . The following
requirements are applicable:
• Front Setback – 35’
• Side Setback – 8’
• Rear Setback – 20’
• Manufactured home long dimension does not have to be parallel to the road.
2. The distance of the existing manufactured home from the northern side property line has
been confirmed by separate survey commissioned by the applicant.
3. The exact distance of the accessory structure from the northern side property is shown to
be 4 ft. based on the survey commissioned by the applicant.
4. Septic tank and drainfield areas are located to the rear of the existing manufactured home.
5. The property has a modest slope from south to north with a change in grade of +/ 5 ft.
across the property. Along the southern property line there is a noticeable drop (+/- 2-3 ft.)
from the adjacent property, particularly in areas in front of the manufactured home.
In staff’s opinion, the findings above demonstrate that the manufactured home could be placed on
the property in compliance with GR zoning requirements. However, doing so would lead to the
manufactured home being set on the property in a manner that is out of character with other
dwelling placements (i.e., set at undesirable angle or perpendicular to the road) and in a manner that
could potentially impact septic tank location and drainfield areas.
If it is determined that the existing manufactured home needs to be moved from its current
location via a decision by the BOA to not grant the degree of variance request by the applicant,
then it is staff’s opinion that a shift toward the southern property line in the exact same alignment
that the manufactured home currently sit s is the best alternative. This would allow the
manufactured home to remain aligned with other dwellings on this side of Fish Rd., decreases risk
of impacting existing septic tank and drainfield locations, and does not drastically alter the outside
parking and yard areas from how they are currently used. It is important to note that this alternative
would still need variance approval (lesser degree) by the BOA, as required side setbacks could not
be achieved. See below graphic example.
Due to the topographic conditions of the site and the shape o f the subject property it is
recommended that BOA members drive-by the si te to gain a better contextual understanding of
site conditions.
BOA Options
BOA-26-15 contains 2 separate requests. The first is for a relief from side setback requirements to
allow an existing permitted manufactured home not placed in accordance required setback
requirements to be located +/- 3.3 ft. from the northern side property, where the required setback
is 8 ft. The second is for relief from accessory structure side setback requirements to allow for an
existing shed structure to be located +/ - 4ft. from the northern side property line, where the
required setback is 5 ft. Staff has identified the following options avail able to the BOA concerning
action on this request at the July 8, 2026 BOA meeting.
1. Approve both requests as proposed, with the option to add conditions as the BOA deems
necessary to promote public health, safety, or general welfare.
2. Approved one of the requests as proposed, with the option to add conditions as stated
above. Deny the other request.
3. Approve a variance to a lesser degree than requested, with the option to add conditions as
stated above. Example: Require the manufactured home to be moved in manner that
achieves a greater degree of compliance but does not fully comply with applicable
development requirements.
4. Deny both requests.
5. Additional deferral of the request is not an option.
Exhibit 1
Exhibit 2
Exhibit 3
Exhibit 4
Exhibit 5
Approximate Septic
Drainfield Area
Location
Approximate Septic
Tank Location
Exhibit 6
204 ft.
202 ft.
200 ft.
Exhibit 7
Photo 1
Description: Front of manufactured home along Fish Rd.
Exhibit 8
Photo 2
Description: Rear of manufactured home, facing Fish Rd. along the northern side property
line.
Photo 3
Description: Front of manufactured home facing the rear lot line along the southern side
property line.
Photo 4
Description: Rear of manufactured home, facing northern side property line. Stakes in yard
mark septic drainfield areas.
Source: City of Sumter website. First collected Oct 24, 2026.