BOA-25-27, 2434 Wedgefield Rd. (City) - Staff Report

City of Sumter · Sumter County · Other

Open the original document More from City of Sumter

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Sumter City-County Zoning Board of Appeals October 8, 2025 BOA-25-27 2434 Wedgefield Rd (City) The applicant (Duke Energy Progress, Inc.) is requesting that the Sumter City-County Board of Zoning Appeals grant special exception approval for the establishment of a +/- 120 ft. tall monopole telecommunications tower in a residential zoning district pursuant to Article 3, Exhibit 3-5: Permitted Uses in All Zoning Districts; Article 5.b.2. Enumeration of Certain Hazardous and/or Potentially Disruptive Land Development Activities; and Article 5.b.4: Communication Towers and Antennae of the City of Sumter Zoning & Development Standards Ordinance. The telecommunications tower is proposed to be located within the area of an existing electrical utility substation on the property. The property is located at 2434 Wedgefield Rd., is zoned Residential-15 (R-15), and is represented by TMS# 206-00-02-010. 2 Sumter City-County Zoning Board of Appeals October 8, 2025 BOA-25-27 2434 Wedgefield Rd I. THE REQUEST Applicant: Duke Energy Progress Inc. Status of the Applicant: Authorized Agent Request: Special Exception approval to establish a monopole telecommunications tower on the property. City Council Ward Ward 6 Location: 2434 Wedgefield Rd. Present Use/Zoning: Duke Energy Electrical Substation / Residential-15 (R-15) Tax Map Reference: 206-00-02-010 II. BACKGROUND The applicant requests approval to construct a 120 ft. tall monopole telecommunications tower on property addressed as 2434 Wedgefield Rd.. The location of the property indicated in red on the map to the right. As shown in Figure 1 , one page 2 of this report. the proposed location is near the front of the property and over 190 ft. from all property lines. Duke Energy is requesting the placement of this tower to enhance its internal communications. The improved infrastructure will allow for faster notification of power outages in the area and more efficient coordination of response efforts. Telecommunications towers (NAICS 517) located within any residential zoning district are required to be reviewed and approved as a Special Exception Use. Special Exceptions are to be 3 evaluated in accordance with Article 1.h.4.c and Article 3.b.4.a. and in accordance with Article 5.b.4. of the City of Sumter Zoning & Development Standards Ordinance: Figure 1: Proposed tower placement location Figure 2: Photo of existing conditions at Wedgefield Rd 4 The applicant has submitted the following information in support of the application, as required under Article 5.b.4. These items are attached to this report as Exhibits 1 -9. Items Needed Date of Submission (Description as Needed) 1. Specifications 7-18-25 2. Site Plan 7-18-25 3. Tower Location Map 7-18-25 • The property is owned by Duke Energy and is zoned R-15. 4. Antenna Capacity/Wind Load 7-18-25 5. Antenna Ownership 7-18-25 6. Owner Authorization 7-18-25 • Duke owns the Property, and has previously developed it with a substation 7. FCC License 7-18-25 8. Visual Impact Analysis 7-18-25 • The proposed tower, antenna or accessory structure will be placed on site in such a manner that it will minimize the visual impact on the surrounding properties 9. Removal Agreement 8-14-25 10. Conditions Met Staff evaluation: all Article 5 conditions appear to have been met, subject to Board of Zoning Appeals Decision regarding Special Exception. Figure 3: Zoning Map 5 III. SPECIAL EXCEPTION REVIEW CRITERIA In Residential-15 (R-15) zoning districts, telecommunication towers are special exception uses requiring the review and approval of the Board of Zoning Appeals. Special exception requests for telecommunications towers are evaluated in accordance with Article 1.h.4.c. and Article 5.b.4. Article 1.h.4.c: Special Exceptions 2. Permits for Special Exceptions shall be evaluated by the Board of Zoning Appeals on the basis of the following criteria: a. That the Special Exception complies with all applicable development standards contained elsewhere in this Ordinance, including landscaping and bufferyards, off-street parking, and dimensional requirements; Staff Review: The proposed tower will be located in an existing Duke Energy Electrical Substation. Based on staff ’s evaluation, the site meets minimum development standards applicable to the proposed commercial use, not including the special design criteria in Article 5.b.4. b. That the special exception will be in substantial harmony with the area in which it is located; Staff Review: The property is zoned Residential-15 (R-15) and is in the Suburban Development Planning Area according to the 2040 Comprehensive Land Use Plan. Staff is of the opinion that the construction of the proposed tower will be in substantial harmony with the surrounding area , based on the existing utility development on the property. c. That the special exception will not discourage or negate the use of surrounding property for use(s) permitted by right. Staff Review: The proposed tower will be set back over 190 ft. from all property lines and is not expected to cause any negative impacts that would discourage or negate use of surrounding properties. Article 5.b.4. Communication Towers and Antennas: 1. Location and Visual Impact: The proposed tower, antenna or accessory structure will be placed on site in such a manner that it will minimize the visual impact on the surrounding properties; Staff Review: According to the visual impact analysis, the view of the tower from surrounding property and right -of-way will be minimal. T he property is naturally 6 buffered by surrounding vegetation, which will serve as a visual screen, further reducing its visibility. 2. Inability to locate on existing structures: The applicant must show that a proposed antenna and equipment cannot be accommodated and function as required by applicable regulations and the applicants’ technical design requirements without unreasonable modifications on any existing structure or tower under control of applicant, or to locate on an available and suitable nearby tower at reasonable costs (i.e., at or below local area rent average); Staff Review: The property is owned by Duke Energy, which has developed a n electric substation on the site. The proposed tower would be an operational addition to the existing facility, as it is specifically designed to interface with the substation and enhance response times in the event of an emergency/power outage. 3. Necessity for location in residential district: The applicant must show that the portion of the city and/or county intended to receive coverage cannot be adequately served by a communications tower or antenna placed in a non- residential district for valid technical reasons; Staff Review: The property, acquired by Duke Energy in 1993, is zoned Residential-15 (R-15). As previously mentioned, a Duke Energy electric utility substation already exists on the site, which is a permitted by- right use in a residential zone. 4. Public property or other private property not suitable: Prior to consideration of a permit for location on private property which must be acquired, the applicant must show that available publicly owned sites, and available privately owned sites occupied by a compatible use, are unsuitable for operation of the facility under applicable communications regulations and the applicant’s technical design requirements; Staff Review: The subject property is owned by Duke Energy, and this tower is specifically to serve the substation as part of Duke’s communications and monitoring systems. 5. Design for multiple use: Applicants must show that a new tower is designed to accommodate additional antennae equal to applicant’s present and future requirements; Staff Review: According to the applicant, no additional antennas from other telecommunications providers will be permitted due to operational security and safety concerns, as the tower will be located within the electric substation and the tower’s purpose is to facilitate the company’s communications with elements of the electrical grid. 6. Safety Codes Met: Applicant must show that all applicable health, nuisance, fire, building, and life safety code requirements are met; 7 Staff Review: The applicant must obtain all required building permits. The Sumter City-County building inspections department will inspect the construction project to ensure that code requirements are met. 7. Paint and illumination: A communications tower must not be painted or illuminated unless otherwise required by state or federal regulations. Staff Review: The tower will meet FCC and FAA requirements for visibility; no other painting or illumination is proposed. 8. Distance from existing tower: A permit for a proposed tower site within 1,000 ft of an existing tower shall not be issued unless the applicant certifies that the existing tower does not meet the applicants structural specifications and design requirements, or that a co-location agreement could not be obtained; Staff Review: The unique nature of this tower, serving as a communications link between Duke Energy’s facilities and the substation on the property, also means that no existing tower in the vicinity is able to meet the applicant’s technical specifications. 9. Indemnity and claims resolution: The applicant must show by certification from a registered professional engineer that the proposed facility will contain only equipment meeting FCC rules, and must file with the Zoning Administrator a written indemnification of the city or county of Sumter and proof of liability insurance or financial ability to respond to claims up to $1,000,000.00 in the aggregate which may arise from the operation of the facilities during its life, at not cost to the city and county and in a form approved by the City of County Attorneys. Staff Review The applicant has submitted proof of adequate insurance. 10. Minimum Setback: A tower must be set back from all lot lines by a distance equal to the district setback requirement or 100% of the tower height, whichever is greater; Staff Review: The proposed tower is to be set back from all lot lines by a height equal to or greater than 120 ft. (height of the tower). 11. Technical Assistance: Prior to issuing a permit, the Zoning Administrator may make use of professional technical services to determine if the standards in Article 5.b.4.d. are met; Not Applicable 12. Maintenance: The communications tower shall be maintained by common corrosion control procedures so it continuously maintains a minimum visual impact on surrounding properties. 8 Staff Review: the proposed tower will be maintained will be done by Duke Energy. IV. STAFF RECOMMENDATION Staff recommends no additional conditions of approval if the Board makes the necessary findings to approve this request. V. DRAFT MOTIONS for BOA-25-27 A. I move the Zoning Board of Appeals approve BOA-25-27, subject to the findings of fact and conclusions developed by the BZA and so stated: B. I move the Zoning Board of Appeals deny BOA-25-27, subject to the following findings of fact and conclusions: C. I move the Zoning Board of Appeals enter an alternative motion for BOA-25-27. VI. BOARD OF APPEALS – October 8, 2025 Date: 07/11/2025 Robert Jackson Engineered Tower Solutions, PLLC Sr Telecom Analyst 3227 Wellington Court Duke Energy Raleigh, NC 27615 910-523-8708 (919) 782-2710 Robert.Jackson3@duke-energy.com Subject: Structural Analysis Report Duke Energy Designation: Duke Energy Site Name: Sumter Wedgefield Road 230 Sub Engineering Firm Designation: ETS, PLLC Job Number: 24131425.STR.3889 Site Data: 2434 Wedgefield Rd, Sumter, Sumter County, SC 29154 Latitude 33.912755°, Longitude -80.393316° 140-ft Valmont H10 (Direct Bury 120-ft AGL) – Monopole Dear Robert Jackson, Engineered Tower Solutions, PLLC is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: Final Equipment Configuration: Tower: 89.8% Sufficient Capacity Foundation: 101.9% Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 133 mph as required by the 2021 International Building Code. Applicable Standard references and design criteria are listed in Section 2 – Analysis Criteria. Structural Analysis Report prepared by: J. Scott Hilgoe, PE Structural Engineering Manager Respectfully submitted by: Christopher G. Ply, PE, SE President / CEO 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 2 tnxTower Report - version 8.3.1.2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 - Tower Component Stresses vs. Capacity 4.1) Recommendations 4.2) Dish Deflection Table 5) APPENDIX A tnxTower Output 6) APPENDIX B Pole Design Specifications 7) APPENDIX C Additional Calculations 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 3 tnxTower Report - version 8.3.1.2 1) INTRODUCTION This tower is a proposed 140-ft Valmont Class H10 direct-embedded monopole tower designed by Valmont. This pole is to be embedded 20-ft for a final height above grade of 120-ft. The embedded pole has been designed considering a surrounding gravel annulus of 12” larger than the bottom pole diameter. 2) ANALYSIS CRITERIA Building Code: 2018 IBC TIA-222 Revision: TIA-222-H Risk Category: III Wind Speed: 133 mph Exposure Category: C Topographic Factor: 1 Ice Thickness: 1.0 in Wind Speed With Ice: 30 mph Service Wind Speed: Ss: S1: 60 mph 0.384 0.128 Table 1 - Proposed Equipment Configuration Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 118.0 (Duke Energy) 118.0 1 Radiowaves HPD4-5.2 1 CAT5E 1 Cambium PMP450I Non-Integrated 2 Tower Mounts Stiff Arm/Stabilizer Bar 1 SitePro 1 DCH8 Chain Mount 1 Tower Mount 2.375"ø x 2-ft Pipe Mount 1 Tower Mount 4.5"ø x 5-ft Pipe Mount Table 2 - Other Considered Equipment Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 60.0 * (Future) 60.0 9 JMA X7CQAP-86-880-VR0 15 1-5/8 Hybrid 9 Ericsson RRUS 32 3 Raycap DC6-48-60-18-8C 1 Perfect-Vision PV-LPPGS-12M-HR2-AP19-AT (12.5 ft Platform Mount) *Future LTE loading considered in this analysis. 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 4 tnxTower Report - version 8.3.1.2 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Document Remarks Reference Source Tower Design Drawings/Pole Specifications Valmont H10 SW10 CS78231 (Drawing No. 307137Z) 01/19/2021 On File Path Study Cambium Networks Link Planner (Proj. DEP 04-04-23_png) 10/28/2024 On File Geotechnical Report ETS, PLLC (Job Number: 24131425) 06/19/2025 On File 3.1) Analysis Method tnxTower (version 8.3.1.2), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built and have been maintained in accordance with the manufacturer’s specifications. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Table(s) 1 and 2 and the referenced drawings. 3) The proposed cables were assumed to be banded to the exterior of the pole. This analysis may be affected if any assumptions are not valid or have been made in error. Engineered Tower Solutions, PLLC should be notified to determine the effect on the structural integrity of the tower. 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 5 tnxTower Report - version 8.3.1.2 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Section No. Elevation (ft) Component Type Size Critical Element P (K) SF*P_allow (K) % Capacity Pass / Fail L1 120 - 67.0833 Pole TP26.08x16.51x0.22 1 -2.715 1035.760 29.9 Pass L2 67.0833 - 31.6667 Pole TP32.05x24.89x0.25 2 -10.305 1456.360 64.6 Pass L3 31.6667 - 0 Pole TP37.28x30.68x0.28 3 -16.608 1958.240 89.8 Pass Summary Pole (L3) 89.8 Pass RATING = 89.8 Pass Table 5 - Tower Component Stresses vs. Capacity Notes Component Elevation (ft) % Capacity Pass / Fail 1 Embedded Pole Foundation 0 91.4 Pass 1,2 Base Foundation Soil Interaction 0 101.9 Pass Structure Rating (max from all components) = 101.9% 2 Notes: 1) See additional documentation in “Appendix C - Additional Calculations” for calculations supporting the % capacity consumed. 2) Capacity usage up to 105% is considered acceptable. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the final load configuration. No modifications are required at this time. 4.2) Proposed Dish Antenna Deflection Results As requested, the results of the tilt and twist values for a 60 mph 3-second gust service wind speed per the TIA-222-H standard are given below: Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 118.00 HPD4-5.2 48 13.00 0.81 0.01 104440 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 6 tnxTower Report - version 8.3.1.2 APPENDIX A TNXTOWER OUTPUT ETS, PLLC 3227 Wellington Court Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Job: Sumter Wedgefield Road 230 Sub Project: ETS, PLLC Job No.24131425.STR.3889 Client: Duke Energy Drawn by: J. Scott Hilgoe, PE App'd: Code: TIA-222-H Date: 07/11/25 Scale: NTS Path: C:\Users\scott.hilgoe.ETS\OneDrive - Engineered Tower Solutions\Desktop\Working Folder\Duke\Sumter Wedgefield\Analysis\Tower\Sumter Wedgefield.eri Dwg No. E-1 120.0 ft 67.1 ft 31.7 ft 0.0 ft REACTIONS - 133 mph WIND TORQUE 3 kip-ft 22 K SHEAR 1359 kip-ft MOMENT 17 K AXIAL 30 mph WIND - 1.00 in ICE TORQUE 0 kip-ft 1 K SHEAR 94 kip-ft MOMENT 30 K AXIAL ARE FACTORED ALL REACTIONS Section 123 Length (ft) 52.9239.5836.50 Number of Sides 121212 Thickness (in) 0.220.250.28 Socket Length (ft) 4.174.83 Top Dia (in) 16.5124.8930.68 Bot Dia (in) 26.0832.0537.28 Grade A572-65 Weight (K) 2.73.13.89.5 1/2-in x 4-ft Lightning Rod 120 4.5" x 5-ft Pipe Mount w/ DCH8 Chain Mount 118 2.4" x 2-ft Pipe Mount 118 (2) Pipe Mount/Stabilizer 118 PMP 450I 118 HPD4-5.2 118 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) RRUS 32 60 (3) RRUS 32 60 (3) RRUS 32 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 PV-LPPGS-12M-HR2-AP19 60DESIGNED APPURTENANCE LOADING TYPE TYPEELEVATION ELEVATION 1/2-in x 4-ft Lightning Rod 120 4.5" x 5-ft Pipe Mount w/ DCH8 Chain Mount 118 2.4" x 2-ft Pipe Mount 118 (2) Pipe Mount/Stabilizer 118 PMP 450I 118 HPD4-5.2 118 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) RRUS 32 60 (3) RRUS 32 60 (3) RRUS 32 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 PV-LPPGS-12M-HR2-AP19 60 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. 2. Tower designed for a 133 mph basic wind in accordance with the TIA-222-H Standard. 3. Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to increase in thickness with height. 4. Deflections are based upon a 60 mph wind. 5. Tower Risk Category III. 6. Topographic Category 1 with Crest Height of 0.00 ft 7. TOWER RATING: 89.8% ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 1 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE  Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower base elevation above sea level: 183.87 ft. Basic wind speed of 133 mph. Risk Category III. Exposure Category C. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category: 1. Crest Height: 0.00 ft. Nominal ice thickness of 1.00 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. Non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Horizontals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Consider Moments - Diagonals √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression Use Moment Magnification Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Stress Ratios Retension Guys To Initial Tension Offset Girt At Foundation √ Use Code Safety Factors - Guys √ Bypass Mast Stability Checks √ Consider Feed Line Torque Escalate Ice √ Use Azimuth Dish Coefficients Include Angle Block Shear Check Always Use Max Kz √ Project Wind Area of Appurtenances Use TIA-222-H Bracing Resist. Exemption Kz In Exposure D Hurricane Region Alternative Appurt. EPA Calculation Use TIA-222-H Tension Splice Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section Add IBC .6D+W Combination √ Include Shear-Torsion Interaction Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Pole Without Linear Attachments SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole With Shroud Or No Appurtenances Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Outside and Inside Corner Radii Are Known Use Special Wind Profile Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 120.00-67.08 52.92 4.17 12 16.51 26.08 0.22 0.88 A572-65 (65 ksi) L2 67.08-31.67 39.58 4.83 12 24.89 32.05 0.25 1.00 A572-65 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 2 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade (65 ksi) L3 31.67-0.00 36.50 12 30.68 37.28 0.28 1.12 A572-65 (65 ksi) Tapered Pole Properties Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 17.02 11.49 389.16 5.83 8.55 45.50 788.55 5.65 3.84 17.524 26.92 18.24 1556.76 9.26 13.51 115.24 3154.42 8.98 6.40 29.235 L2 26.46 19.83 1536.82 8.82 12.89 119.21 3114.01 9.76 6.00 24 33.09 25.60 3304.18 11.38 16.60 199.02 6695.16 12.60 7.92 31.678 L3 32.56 27.50 3242.91 10.88 15.89 204.09 6571.01 13.54 7.47 26.576 38.49 33.47 5847.83 13.24 19.31 302.85 11849.29 16.48 9.24 32.872 Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L1 120.00-67.08 1 1 1 L2 67.08-31.67 1 1 1 L3 31.67-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Exclude From Torque Calculation Component Type Placement ft Total Number Number Per Row Start/End Position Width or Diameter in Perimeter in Weight plf *** Safety Line 3/8 C No Surface Ar (CaAa) 120.00 - 5.00 1 1 0.000 0.000 0.38 0.22 Step Pegs (5/8'' SR) 7-in. w/ 30'' Step C No Surface Ar (CaAa) 120.00 - 5.00 2 2 0.000 0.000 0.35 0.49 *** CAT5E(1/4) A No Surface Ar (CaAa) 118.00 - 5.00 1 1 -0.100 0.100 0.25 0.10 *** 1 5/8 C No Surface Ar (CaAa) 60.00 - 5.00 15 8 -0.100 0.100 1.98 1.04 *** Feed Line/Linear Appurtenances - Entered As Area ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 3 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number C AAA ft2/ft Weight plf *** Feed Line/Linear Appurtenances Section Areas Tower Section Tower Elevation ft Face A R ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 120.00-67.08 A B C 0.000 0.000 0.000 0.000 0.000 0.000 1.273 0.000 5.689 0.000 0.000 0.000 0.005 0.000 0.063 L2 67.08-31.67 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.885 0.000 48.687 0.000 0.000 0.000 0.004 0.000 0.484 L3 31.67-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.667 0.000 45.107 0.000 0.000 0.000 0.003 0.000 0.448 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section Tower Elevation ft Face or Leg Ice Thickness in AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 120.00-67.08 A B C 1.274 0.000 0.000 0.000 0.000 0.000 0.000 14.247 0.000 36.954 0.000 0.000 0.000 0.126 0.000 0.352 L2 67.08-31.67 A B C 1.197 0.000 0.000 0.000 0.000 0.000 0.000 9.910 0.000 89.858 0.000 0.000 0.000 0.088 0.000 2.260 L3 31.67-0.00 A B C 1.068 0.000 0.000 0.000 0.000 0.000 0.000 7.048 0.000 78.468 0.000 0.000 0.000 0.059 0.000 2.028 Feed Line Center of Pressure Section Elevation ft CPX in CPZ in CPX Ice in CPZ Ice in L1 120.00-67.08 -0.12 0.55 -0.67 1.61 L2 67.08-31.67 -0.08 6.34 -0.51 5.95 L3 31.67-0.00 -0.07 6.57 -0.46 6.37 Note: For pole sections, center of pressure calculations do not consider feed line shielding. ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 4 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Shielding Factor Ka Tower Section Feed Line Record No. Description Feed Line Segment Elev. Ka No Ice Ka Ice L1 2 Safety Line 3/8 67.08 - 120.00 1.0000 1.0000 L1 3 Step Pegs (5/8'' SR) 7-in. w/ 30'' Step 67.08 - 120.00 1.0000 1.0000 L1 6 CAT5E(1/4) 67.08 - 118.00 1.0000 1.0000 L2 2 Safety Line 3/8 31.67 - 67.08 1.0000 1.0000 L2 3 Step Pegs (5/8'' SR) 7-in. w/ 30'' Step 31.67 - 67.08 1.0000 1.0000 L2 6 CAT5E(1/4) 31.67 - 67.08 1.0000 1.0000 L2 8 1 5/8 31.67 - 60.00 1.0000 1.0000 L3 2 Safety Line 3/8 5.00 - 31.67 1.0000 1.0000 L3 3 Step Pegs (5/8'' SR) 7-in. w/ 30'' Step 5.00 - 31.67 1.0000 1.0000 L3 6 CAT5E(1/4) 5.00 - 31.67 1.0000 1.0000 L3 8 1 5/8 5.00 - 31.67 1.0000 1.0000 Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft C AAA Front ft2 CAAA Side ft2 Weight K *** 1/2-in x 4-ft Lightning Rod A From Leg 0.00 0.00 2.00 0.00 120.00 No Ice 1/2'' Ice 1'' Ice 0.20 0.61 0.95 0.20 0.61 0.95 0.003 0.005 0.010 *** 4.5'' x 5-ft Pipe Mount w/ DCH8 Chain Mount C From Leg 1.00 0.00 0.00 0.00 118.00 No Ice 1/2'' Ice 1'' Ice 1.48 2.08 2.40 1.48 2.08 2.40 0.000 0.000 0.000 2.4'' x 2-ft Pipe Mount C From Leg 1.00 0.00 0.00 0.00 118.00 No Ice 1/2'' Ice 1'' Ice 0.34 0.47 0.61 0.34 0.47 0.61 0.000 0.000 0.000 (2) Pipe Mount/Stabilizer C From Leg 0.50 0.00 0.00 0.00 118.00 No Ice 1/2'' Ice 1'' Ice 0.42 0.57 0.73 0.42 0.57 0.73 0.000 0.000 0.000 PMP 450I C From Leg 1.00 0.00 0.00 0.00 118.00 No Ice 1/2'' Ice 1'' Ice 1.62 1.90 2.18 0.96 1.20 1.47 0.015 0.031 0.049 *** PV-LPPGS-12M-HR2-AP19 C None 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 19.00 25.60 32.20 19.00 25.60 32.20 2.000 2.400 2.800 (3) X7CQAP-86-880-VR0_TIA A From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 13.44 14.04 14.65 9.06 9.66 10.26 0.072 0.153 0.242 (3) X7CQAP-86-880-VR0_TIA B From Leg 4.00 0.00 0.00 60.00 No Ice 1/2'' Ice 13.44 14.04 9.06 9.66 0.072 0.153 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 5 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft C AAA Front ft2 CAAA Side ft2 Weight K 0.00 1'' Ice 14.65 10.26 0.242 (3) X7CQAP-86-880-VR0_TIA C From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 13.44 14.04 14.65 9.06 9.66 10.26 0.072 0.153 0.242 (3) RRUS 32 A From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 2.86 3.08 3.32 1.78 1.97 2.17 0.055 0.077 0.103 (3) RRUS 32 B From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 2.86 3.08 3.32 1.78 1.97 2.17 0.055 0.077 0.103 (3) RRUS 32 C From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 2.86 3.08 3.32 1.78 1.97 2.17 0.055 0.077 0.103 DC6-48-60-18-8C A From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 1.14 1.79 2.00 1.14 1.79 2.00 0.026 0.047 0.070 DC6-48-60-18-8C B From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 1.14 1.79 2.00 1.14 1.79 2.00 0.026 0.047 0.070 DC6-48-60-18-8C C From Leg 4.00 0.00 0.00 0.00 60.00 No Ice 1/2'' Ice 1'' Ice 1.14 1.79 2.00 1.14 1.79 2.00 0.026 0.047 0.070 *** Dishes Description Face or Leg Dish Type Offset Type Offsets: Horz Lateral Vert ft Azimuth Adjustment ° 3 dB Beam Width ° Elevation ft Outside Diameter ft Aperture Area ft2 Weight K *** HPD4-5.2 B Paraboloid w/Shroud (HP) From Leg 1.00 0.00 0.00 -16.46 118.00 4.00 No Ice 1/2'' Ice 1'' Ice 12.57 13.10 13.62 0.090 0.150 0.220 *** Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 6 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Comb. No. Description 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind 90 deg - No Ice 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service 42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service Maximum Member Forces Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L1 120 - 67.0833 Pole Max Tension 2 0.000 0.00 -0.00 Max. Compression 26 -5.453 -0.19 -0.55 Max. Mx 20 -2.715 174.50 6.15 Max. My 14 -2.780 -9.91 -151.94 Max. Vy 20 -6.293 174.50 6.15 Max. Vx 14 5.797 -9.91 -151.94 Max. Torque 5 -1.02 L2 67.0833 - 31.6667 Pole Max Tension 1 0.000 0.00 0.00 Max. Compression 26 -20.297 -0.10 -3.59 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 7 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft Max. Mx 20 -10.305 626.47 10.30 Max. My 14 -10.411 -17.41 -573.06 Max. Vy 20 -17.618 626.47 10.30 Max. Vx 14 16.185 -17.41 -573.06 Max. Torque 9 -3.49 L3 31.6667 - 0 Pole Max Tension 1 0.000 0.00 0.00 Max. Compression 26 -29.800 -0.02 -7.53 Max. Mx 20 -16.608 1359.15 14.27 Max. My 14 -16.612 -25.13 -1239.41 Max. Vy 20 -22.367 1359.15 14.27 Max. Vx 14 20.164 -25.13 -1239.41 Max. Torque 9 -3.48 Maximum Reactions Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Pole Max. Vert 26 29.800 0.000 0.001 Max. Hx 21 12.472 22.351 0.134 Max. Hz 3 12.472 0.213 20.125 Max. Mx 2 1232.57 0.213 20.125 Max. Mz 8 1334.68 -22.147 -0.092 Max. Torsion 21 3.39 22.351 0.134 Min. Vert 15 12.472 -0.206 -20.149 Min. Hx 8 16.630 -22.147 -0.092 Min. Hz 14 16.630 -0.206 -20.150 Min. Mx 14 -1239.41 -0.206 -20.150 Min. Mz 20 -1359.15 22.351 0.134 Min. Torsion 9 -3.48 -22.146 -0.092 Tower Mast Reaction Summary Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead Only 13.858 -0.000 -0.000 1.58 -0.10 0.00 1.2 Dead+1.0 Wind 0 deg - No Ice 16.630 -0.213 -20.125 -1232.57 25.73 0.37 0.9 Dead+1.0 Wind 0 deg - No Ice 12.472 -0.213 -20.125 -1226.60 25.58 0.37 1.2 Dead+1.0 Wind 30 deg - No Ice 16.630 10.285 -17.361 -1058.92 -644.39 -1.66 0.9 Dead+1.0 Wind 30 deg - No Ice 12.472 10.285 -17.361 -1053.83 -640.90 -1.66 1.2 Dead+1.0 Wind 60 deg - No Ice 16.630 18.256 -10.150 -602.72 -1129.43 0.92 0.9 Dead+1.0 Wind 60 deg - No Ice 12.472 18.256 -10.150 -600.08 -1123.39 0.92 1.2 Dead+1.0 Wind 90 deg - No Ice 16.630 22.147 0.092 13.08 -1334.68 3.48 0.9 Dead+1.0 Wind 90 deg - No Ice 12.472 22.146 0.092 12.51 -1327.62 3.48 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 8 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft 1.2 Dead+1.0 Wind 120 deg - No Ice 16.630 18.215 10.380 634.44 -1124.36 0.40 0.9 Dead+1.0 Wind 120 deg - No Ice 12.472 18.215 10.380 630.62 -1118.35 0.40 1.2 Dead+1.0 Wind 150 deg - No Ice 16.630 10.431 17.375 1064.48 -662.00 -2.64 0.9 Dead+1.0 Wind 150 deg - No Ice 12.472 10.431 17.375 1058.40 -658.40 -2.64 1.2 Dead+1.0 Wind 180 deg - No Ice 16.630 0.206 20.150 1239.41 -25.13 -0.60 0.9 Dead+1.0 Wind 180 deg - No Ice 12.472 0.206 20.149 1232.34 -24.92 -0.60 1.2 Dead+1.0 Wind 210 deg - No Ice 16.630 -10.324 17.318 1057.60 648.76 1.93 0.9 Dead+1.0 Wind 210 deg - No Ice 12.472 -10.324 17.318 1051.56 645.31 1.93 1.2 Dead+1.0 Wind 240 deg - No Ice 16.630 -18.431 10.132 604.38 1150.25 -0.63 0.9 Dead+1.0 Wind 240 deg - No Ice 12.472 -18.430 10.132 600.77 1144.12 -0.63 1.2 Dead+1.0 Wind 270 deg - No Ice 16.630 -22.351 -0.134 -14.27 1359.15 -3.39 0.9 Dead+1.0 Wind 270 deg - No Ice 12.472 -22.351 -0.134 -14.65 1352.03 -3.39 1.2 Dead+1.0 Wind 300 deg - No Ice 16.630 -18.417 -10.442 -638.17 1148.60 -0.72 0.9 Dead+1.0 Wind 300 deg - No Ice 12.472 -18.417 -10.442 -635.27 1142.48 -0.72 1.2 Dead+1.0 Wind 330 deg - No Ice 16.630 -10.598 -17.426 -1066.71 682.01 2.16 0.9 Dead+1.0 Wind 330 deg - No Ice 12.472 -10.598 -17.426 -1061.56 678.32 2.16 1.2 Dead+1.0 Ice+1.0 Temp 29.800 -0.000 -0.001 7.53 -0.02 0.00 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 29.800 -0.012 -1.368 -78.59 1.46 0.01 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29.800 0.696 -1.181 -66.56 -44.66 -0.09 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 29.800 1.204 -0.673 -34.12 -77.01 0.05 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 29.800 1.385 0.005 8.26 -88.30 0.19 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 29.800 1.201 0.686 50.96 -76.72 0.03 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 29.800 0.705 1.182 81.90 -45.67 -0.12 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 29.800 0.011 1.369 94.00 -1.45 -0.02 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 29.800 -0.699 1.179 81.51 44.89 0.10 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 29.800 -1.213 0.672 49.24 78.17 -0.03 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 29.800 -1.396 -0.007 6.70 89.68 -0.18 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 29.800 -1.213 -0.689 -36.15 78.08 -0.05 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 29.800 -0.714 -1.185 -67.01 46.79 0.10 Dead+Wind 0 deg - Service 13.858 -0.039 -3.669 -222.83 4.59 0.07 Dead+Wind 30 deg - Service 13.858 1.875 -3.165 -191.24 -117.21 -0.30 Dead+Wind 60 deg - Service 13.858 3.328 -1.850 -108.32 -205.38 0.17 Dead+Wind 90 deg - Service 13.858 4.037 0.017 3.63 -242.71 0.64 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 9 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead+Wind 120 deg - Service 13.858 3.321 1.892 116.59 -204.46 0.07 Dead+Wind 150 deg - Service 13.858 1.902 3.168 194.76 -120.41 -0.48 Dead+Wind 180 deg - Service 13.858 0.038 3.674 226.56 -4.64 -0.11 Dead+Wind 210 deg - Service 13.858 -1.882 3.157 193.51 117.84 0.35 Dead+Wind 240 deg - Service 13.858 -3.360 1.847 111.14 209.00 -0.12 Dead+Wind 270 deg - Service 13.858 -4.074 -0.024 -1.33 247.00 -0.62 Dead+Wind 300 deg - Service 13.858 -3.357 -1.904 -114.76 208.71 -0.13 Dead+Wind 330 deg - Service 13.858 -1.932 -3.177 -192.66 123.88 0.40 Solution Summary Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 1 0.000 -13.858 0.000 0.000 13.858 0.000 0.000% 2 -0.213 -16.630 -20.127 0.213 16.630 20.125 0.007% 3 -0.213 -12.472 -20.127 0.213 12.472 20.125 0.006% 4 10.286 -16.630 -17.361 -10.285 16.630 17.361 0.001% 5 10.286 -12.472 -17.361 -10.285 12.472 17.361 0.001% 6 18.257 -16.630 -10.150 -18.256 16.630 10.150 0.001% 7 18.257 -12.472 -10.150 -18.256 12.472 10.150 0.001% 8 22.147 -16.630 0.092 -22.147 16.630 -0.092 0.001% 9 22.147 -12.472 0.092 -22.146 12.472 -0.092 0.002% 10 18.215 -16.630 10.380 -18.215 16.630 -10.380 0.001% 11 18.215 -12.472 10.380 -18.215 12.472 -10.380 0.001% 12 10.431 -16.630 17.375 -10.431 16.630 -17.375 0.001% 13 10.431 -12.472 17.375 -10.431 12.472 -17.375 0.000% 14 0.206 -16.630 20.151 -0.206 16.630 -20.150 0.003% 15 0.206 -12.472 20.151 -0.206 12.472 -20.149 0.006% 16 -10.324 -16.630 17.318 10.324 16.630 -17.318 0.001% 17 -10.324 -12.472 17.318 10.324 12.472 -17.318 0.001% 18 -18.431 -16.630 10.132 18.431 16.630 -10.132 0.001% 19 -18.431 -12.472 10.132 18.430 12.472 -10.132 0.001% 20 -22.352 -16.630 -0.134 22.351 16.630 0.134 0.003% 21 -22.352 -12.472 -0.134 22.351 12.472 0.134 0.002% 22 -18.417 -16.630 -10.443 18.417 16.630 10.442 0.001% 23 -18.417 -12.472 -10.443 18.417 12.472 10.442 0.001% 24 -10.598 -16.630 -17.426 10.598 16.630 17.426 0.001% 25 -10.598 -12.472 -17.426 10.598 12.472 17.426 0.001% 26 0.000 -29.800 0.000 0.000 29.800 0.001 0.003% 27 -0.012 -29.800 -1.369 0.012 29.800 1.368 0.002% 28 0.697 -29.800 -1.181 -0.696 29.800 1.181 0.002% 29 1.204 -29.800 -0.673 -1.204 29.800 0.673 0.002% 30 1.385 -29.800 0.005 -1.385 29.800 -0.005 0.002% 31 1.202 -29.800 0.686 -1.201 29.800 -0.686 0.002% 32 0.705 -29.800 1.182 -0.705 29.800 -1.182 0.002% 33 0.011 -29.800 1.370 -0.011 29.800 -1.369 0.002% 34 -0.699 -29.800 1.179 0.699 29.800 -1.179 0.002% 35 -1.214 -29.800 0.672 1.213 29.800 -0.672 0.002% 36 -1.397 -29.800 -0.007 1.396 29.800 0.007 0.002% 37 -1.213 -29.800 -0.690 1.213 29.800 0.689 0.002% 38 -0.714 -29.800 -1.185 0.714 29.800 1.185 0.002% 39 -0.039 -13.858 -3.670 0.039 13.858 3.669 0.005% 40 1.875 -13.858 -3.166 -1.875 13.858 3.165 0.005% 41 3.329 -13.858 -1.851 -3.328 13.858 1.850 0.005% 42 4.038 -13.858 0.017 -4.037 13.858 -0.017 0.005% 43 3.321 -13.858 1.893 -3.321 13.858 -1.892 0.005% 44 1.902 -13.858 3.168 -1.902 13.858 -3.168 0.005% ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 10 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 45 0.038 -13.858 3.674 -0.038 13.858 -3.674 0.005% 46 -1.882 -13.858 3.158 1.882 13.858 -3.157 0.005% 47 -3.360 -13.858 1.847 3.360 13.858 -1.847 0.005% 48 -4.075 -13.858 -0.024 4.074 13.858 0.024 0.005% 49 -3.358 -13.858 -1.904 3.357 13.858 1.904 0.005% 50 -1.932 -13.858 -3.177 1.932 13.858 3.177 0.005% Non-Linear Convergence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 13 0.00010213 0.00011678 3 Yes 13 0.00007325 0.00009346 4 Yes 16 0.00000001 0.00007378 5 Yes 15 0.00000001 0.00012719 6 Yes 16 0.00000001 0.00007333 7 Yes 15 0.00000001 0.00012612 8 Yes 15 0.00000001 0.00006878 9 Yes 14 0.00000001 0.00011683 10 Yes 16 0.00000001 0.00008547 11 Yes 15 0.00000001 0.00014695 12 Yes 16 0.00000001 0.00009205 13 Yes 16 0.00000001 0.00006989 14 Yes 14 0.00004418 0.00007166 15 Yes 13 0.00007321 0.00012251 16 Yes 16 0.00000001 0.00008479 17 Yes 15 0.00000001 0.00014661 18 Yes 16 0.00000001 0.00008590 19 Yes 15 0.00000001 0.00014788 20 Yes 14 0.00004377 0.00012268 21 Yes 14 0.00000001 0.00009555 22 Yes 16 0.00000001 0.00008496 23 Yes 15 0.00000001 0.00014584 24 Yes 16 0.00000001 0.00008210 25 Yes 15 0.00000001 0.00014130 26 Yes 8 0.00000001 0.00002744 27 Yes 12 0.00000001 0.00003954 28 Yes 12 0.00000001 0.00004116 29 Yes 12 0.00000001 0.00004330 30 Yes 12 0.00000001 0.00004537 31 Yes 12 0.00000001 0.00004779 32 Yes 12 0.00000001 0.00004836 33 Yes 12 0.00000001 0.00004727 34 Yes 12 0.00000001 0.00004762 35 Yes 12 0.00000001 0.00004774 36 Yes 12 0.00000001 0.00004597 37 Yes 12 0.00000001 0.00004444 38 Yes 12 0.00000001 0.00004223 39 Yes 12 0.00000001 0.00007432 40 Yes 12 0.00000001 0.00006555 41 Yes 12 0.00000001 0.00006875 42 Yes 12 0.00000001 0.00008495 43 Yes 12 0.00000001 0.00006972 44 Yes 12 0.00000001 0.00007115 45 Yes 12 0.00000001 0.00007589 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 11 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE 46 Yes 12 0.00000001 0.00006861 47 Yes 12 0.00000001 0.00007180 48 Yes 12 0.00000001 0.00008636 49 Yes 12 0.00000001 0.00006994 50 Yes 12 0.00000001 0.00006681 Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120 - 67.0833 13.34 48 0.82 0.01 L2 71.25 - 31.6667 5.54 48 0.65 0.00 L3 36.5 - 0 1.60 48 0.39 0.00 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 120.00 1/2-in x 4-ft Lightning Rod 48 13.34 0.82 0.01 104440 118.00 HPD4-5.2 48 13.00 0.81 0.01 104440 60.00 PV-LPPGS-12M-HR2-AP19 48 4.03 0.58 0.00 7426 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120 - 67.0833 73.47 20 4.52 0.04 L2 71.25 - 31.6667 30.52 20 3.61 0.02 L3 36.5 - 0 8.82 20 2.13 0.01 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 120.00 1/2-in x 4-ft Lightning Rod 20 73.47 4.52 0.04 19075 118.00 HPD4-5.2 20 71.61 4.49 0.04 19075 60.00 PV-LPPGS-12M-HR2-AP19 20 22.19 3.21 0.02 1353 Compression Checks ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 12 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K Pn K Ratio Pu Pn L1 120 - 67.0833 (1) TP26.08x16.51x0.22 52.92 0.00 0.0 17.71 -2.715 1035.760 0.003 L2 67.0833 - 31.6667 (2) TP32.05x24.89x0.25 39.58 0.00 0.0 24.90 -10.305 1456.360 0.007 L3 31.6667 - 0 (3) TP37.28x30.68x0.28 36.50 0.00 0.0 33.47 -16.608 1958.240 0.008 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft Mnx kip-ft Ratio Mux Mnx Muy kip-ft Mny kip-ft Ratio Muy Mny L1 120 - 67.0833 (1) TP26.08x16.51x0.22 174.61 589.43 0.296 0.00 589.43 0.000 L2 67.0833 - 31.6667 (2) TP32.05x24.89x0.25 626.55 984.12 0.637 0.00 984.12 0.000 L3 31.6667 - 0 (3) TP37.28x30.68x0.28 1359.22 1530.95 0.888 0.00 1530.95 0.000 Pole Shear Design Data Section No. Elevation ft Size Actual Vu K Vn K Ratio Vu Vn Actual Tu kip-ft Tn kip-ft Ratio Tu Tn L1 120 - 67.0833 (1) TP26.08x16.51x0.22 6.295 310.728 0.020 0.71 686.25 0.001 L2 67.0833 - 31.6667 (2) TP32.05x24.89x0.25 17.619 436.908 0.040 3.39 1188.53 0.003 L3 31.6667 - 0 (3) TP37.28x30.68x0.28 22.367 587.473 0.038 3.39 1911.78 0.002 Pole Interaction Design Data Section No. Elevation ft Ratio Pu Pn Ratio Mux Mnx Ratio Muy Mny Ratio Vu Vn Ratio Tu Tn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 120 - 67.0833 (1) 0.003 0.296 0.000 0.020 0.001 0.299 1.000 L2 67.0833 - 31.6667 (2) 0.007 0.637 0.000 0.040 0.003 0.646 1.000 L3 31.6667 - 0 (3) 0.008 0.888 0.000 0.038 0.002 0.898 1.000 ttnnxxTToowweerr Job Sumter Wedgefield Road 230 Sub Page 13 of 13 ETS, PLLC 3227 Wellington Court Project ETS, PLLC Job No.24131425.STR.3889 Date 20:59:39 07/11/25 Raleigh, NC 27615 Phone: (919) 782-2710 FAX: Client Duke Energy Designed by J. Scott Hilgoe, PE Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 120 - 67.0833 Pole TP26.08x16.51x0.22 1 -2.715 1035.760 29.9 Pass L2 67.0833 - 31.6667 Pole TP32.05x24.89x0.25 2 -10.305 1456.360 64.6 Pass L3 31.6667 - 0 Pole TP37.28x30.68x0.28 3 -16.608 1958.240 89.8 Pass Summary Pole (L3) 89.8 Pass RATING = 89.8 Pass  Program Version 8.3.1.2 - 12/11/2024 File:C:/Users/scott.hilgoe.ETS/OneDrive - Engineered Tower Solutions/Desktop/Working Folder/Duke/Sumter Wedgefield/Analysis/Tower/Sumter Wedgefield.eri 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 7 tnxTower Report - version 8.3.1.2 APPENDIX B POLE DESIGN SPECIFICATIONS 0'-0" REFERENCE LINE 307137B____,/ _,,,,-307137C LSPLICE DIMENSION MINIMUM= 38.47" DESIGN = 50.00" MAXIMUM= 56.00" 52' -11" 39' -7" 307137A_/ GROUND LINE LSPLICE DIMENSION MINIMUM= 47.32" DESIGN = 58.00" MAXIMUM= 64.00" ELEVATION VIEW SEE FABRICATION DRAWINGS FOR ADDITIONAL DETAILS 56' -6" 120' -0" 140' -0" 20' -0" 307137B~ ♦ 1.00" NUT I 30.00" (8 PLACES) ! t 12. 00" ♦ 7 t MIN SPLICE MAX s:LICE t [V VALMONT ID TAG~ 307137A [ 1/c__, 8. 00" J t • 30.00" ]--~• 307137C~ ♦ 1.00" NUT I 30.00" (8 PLACES) ! t 12. 00" ~~• -~~7 t MIN SPLICE MAX s:LICE t [ VALMONT ID TAG_/ 307137B [ l)rc--' 8. 00" NOTES: 1. COMPONENT IDENTIFICATION: VALMONT ID TAG LOCATIONS ARE INDICATED BY CALLOUTS ON DRAWING. THE VALMONT ID TAG CONTAINS INFORMATION FOR INTERNAL TRACKING AND FIELD ASSEMBLY. ONLY THE VALMONT PART NUMBER NEEDS TO MATCH FDR FIELD ASSEMBLY, ALL OTHER IDENTIFICATION IS FOR INTERNAL USE. A= MANUFACTURING SITE (ONE CHARACTER) B = VALMONT PART NUMBER (SEVEN CHARACTERS) C = FABRICATION SEQUENCE NUMBER (ONE OR MORE CHARACTERS) D = VALMONT ORDER NUMBER (SIX CHARACTERS) E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE CHARACTERS) I (A) (BBBBBBB) (C) (DDDDDD) (E) I 2. ASSEMBLY AND ERECTION GUIDELINES: SEE VALMONT TRANSMISSION INSTALLATION GUIDELINE 1002 (WWW.VALMONTUTILITY.COM/I002). REFER TO ELEVATION VIEW FOR MINIMUM AND MAXIMUM SPLICE VALUES. REFER TO ELEVATION VIEW FOR MINIMUM AND MAXIMUM SPLICE VALUES. 3. SLIP JOINT JACKING FORCE MINIMUM= 25,000# MAXIMUM= 90,000# SPLICE DETAIL PROPRIETARY INFORMATION THESE DOCUMENTS, DRAWINGS, AND/OR CALCULATIONS AND ALL INFORMATION RELATED TD THEM ARE THE EXCLUSIVE PROPERTY ANO THE PROPRIETARY INFOR­MATION OF VALMONT INDUSTRIES, INC. ANO ARE FURNISHED SOLELY UPON THE CONDITIONS THAT THEY WILL BE RETAINED IN STRICTEST CONFIDENCE AND SHALL NOT BE DUPLICATED, USED, OR DISCLOSED IN WHOLE DR IN PART FOR ANY PURPOSE, IN ANY WAY, WITHOUT THE PRIOR WRITTEN PERMISSION OF VALMONT INDUSTRIES, INC. SPLICE DETAIL VALMONT PART NUMBER BILL OF MATERIAL (SHIPPING SEQ. =1 FOR ALL) DESCRIPTION UNIT QTY WEIGHT PER (LBS) STR 307137A SECTION ASSEMBLY 6,694 1 ~ CLASS H10 307137B SECTION ASSEMBLY 3,130 1 iffi DEP. POLE ID·. 140-A 307137C SECTION ASSEMBLY 2,764 1 rD_U_P_L_IC_A_T_E_D_R_A_W_I_NG_D_I_S_TR_I_B_U_T_IO_N_,I PED487071140' H10 SIDED SW10 CS78231 I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 450 DRAWN I ENGR I DATE I SCALE t---+----t---+--t--------------t AM70 BKB 1 01711?21 NONE P.A. CHK I SHOP CHK r---i-------t--r----t------------p.16"'-M7'--'o~oc=-1~; !.c11,,,,1~2~· i<~M""'s:c,4 ='0~1"';c=-1 '""'9;'-'2'4 valmont -OTHER SPECIFICATIONS V' A O 1/19/21 AM7 KMS REVISED PER DRAFTING ORDER ND· 1 487071 REV CHK BY BY REVISION DESCRIPTION CUSTOMER DUKE MATERIAL ITHICKNESSI WEIGHT 12,588# I DESCRIPTION I DWG NO. 140' H10 SIDED SW10 CS78231 307137Z 1 . 2. 3. LOCATION DIMENSION FROM FROM LARGE END SMALL 0'- 5'- 6'- ~ 30'- 26'- 0. 00" 24' - 0 . 00" . - 22' - 0 . 00" . - 20'- 0. 00" ~ 0'- 7. 00" 0'- 0. 00" ~ - 0'- 0. 00" FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD. ALL CROSS SECTION VIEWS AND ORIENTATION REFERENCES ARE FROM SMALL END OF THE TUBE. ALIGN WITH FLATS AT SMALL END UNLESS OTHERWISE NOTED. END 7. 00" 4. 00" 0. 00" 2.38" DETAIL 3-B 10 9-A 8 7 6 5-A 4 3-A 2 1 4 CUT OFF TAB AFTER PLATE IS WELDED TO SHAFT 2376375 046.00" 0. 188" THK o " V •,J[[]J _______,~ 4 [I]JJ MARK ON BOTTOM OF BEARING PLATE AN APPROXIMATELY 03.00" DOT WITH BLUE PAINT OR MARKER *AFTER GALVANIZING* ~D==E=T::::'.:A :::I L::::::::::1::::'.:::::'.:====:::::B::::E::::'.:A::::'.:R:::;I;::'.:N G;:::::'.:P::::".L".:'.::A=:'.;T::'.'.'.E====~ ~D::'.'.'.E::::'.:T::::'.:A :::I L:::::::::2".:'.::::::'.:=====::::'.:V A::::'.:L::'.:M:::::'.O::::'.:N::::'.:T=::::'.:M::::'.:A::::'.:R I<::'.::====~ DETAIL 5 1. 75" TYP - PART # THICKNESS A 2612752 0 .250" MIN~ T~TYP i BUB DETAIL A 1. 75" ' J 1.50" L VIEW B-B GROUND BRACKET TYPE i FLAT (5) DIMENSION A JACKING 4,10 30.00" ~------4------r i NUT I DIMENSION ' SEE TABLE rn-+--~ i NUT 345170 i FLAT TYP O. 31 DETAIL 9 JACKING HANGING NUTS MARK ON EXTERIOR OF THE SHAFT AN APPROXIMATELY 03.00" DOT WITH BLUE PAINT OR MARKER. FLATS #6 & #12. *AFTER GALVANIZING* VIEW A-A DETAIL 6 VALMONT MARK NOTES: SEAL WELD i OF TAG (Al (BBBBBBB) - (Cl (ODDDDD) - (E) OF FLAT (S) 1 MAXIMUM SLIP STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE REQUIRED INFORMATION SHOWN IN THIS DETAIL PER WORK INSTRUCTION WI-11.02. A MANUFACTURING SITE (ONE CHARACTER) B VALMONT PART NUMBER (SEVEN CHARACTERS) C FABRICATION SEQUENCE NUMBER (ONE OR MORE CHARACTERS) D VALMONT ORDER NUMBER (SIX CHARACTERS) E VALMONT ORDER RELEASE NUMBER (ONE OR MORE CHARACTERS) DETAIL 10 VALMONT ID TAG NOTES: Rt. 06" TYP i FLAT 1n ........... --+--t-- 3. 00" ' I ' I [, 13 1. NOTE FLAT ORIENTATION - i FLAT (S) A 4 B 4. 10 DETAIL 3 HANGING SLOT I CHAR. HEIGHT I i OF FLAT (SI I 0 . 50" I 4 i OF TAG ,,,.... I '--1 SEE ID TAG SHEET PEC FOR REQUIRED STAMPING 2131175_/ i NOTE: SEAL WELD AND VENT ID TAG PER M-91. DETAIL 7 I CUSTOMER ID TAG DUPLICATE DRAWING DISTRIBUTION SEAM WELD 4 SEAL TOP & >--~---hl BOTTOM GROUND LINE NOTE: VENT PER M-41 DETAIL 4 I ' 0 SEAM WELD 1'-0.00". 3'-0.00" =r t 2756409 0 .250" THK GROUND SLEEVE OF FLAT (S) 1 2.00" LONG WELD 0.25" HIGH BEAD i OF WELD BEAD AND FLAT NOTE: CENTER OF GRAVITY IS AN APPROXIMATE LOCATION . THE CALCULATION DOES NOT ACCOUNT FOR WELD MATERIAL OR MATERIAL SUBSTITUTIONS. DETAIL 8 CENTER OF GRAVITY BILL OF MATERIAL (SHIP SEQ=O) VALMONT PART ND DESCRIPTION QTY PER ASSY 2756206 SHAFT 2376375 BEARING PLATE 2756409 GROUND SLEEVE 2 2612752 BRACKET 2 2131175 IDENTIFICATION TAG 345170 1.00" NUT 4 2070063 IDENTIFICATION TAG TMF_SEC_ASSY_41"B0_31"TD __ 56'-6"LG _____ _ DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400 DRAWN ENGR DATE SCALE t---+----+--+--+-------------1 AM70 BKB1 017TT""°;21 NONE P.A. CHK SHOP CHK M7ooT71112 MS401/19/2 valmont -OTHER SPECIFICATIONS V' 1--A-+0-1-/~1-9~/2-1-+A-M-7-+K-M-S+R-E_V_I_S_ED_P_E_R_D_RA_F_T_I_N_G----1 F-1 , M-1 , W-22 LOCATION SYMBOL KEY SHAFT INFO (MEASURED ACROSS FLATS) REV CHK REVISION DESCRIPTION MATERIAL THICKNESS WEIGHT 6,694# ,,,.-. LOCATION '7 REFERENCE SHAPE LENGTH BASE OD TOP OD TAPER THK ASTM 12-SIDED 56'-6.00" 40.89" 30.67" 0.181 0.281" A572 ORDER ND. 487071 BY BY CUSTOMER DUKE DESCRIPTION SECTION ASSEMBLY DWG NO. 307137A 1 . 2. 3. LOCATION DIMENSION FROM FROM LARGE END SMALL END DETAIL ------- 0'-7.00" 1-B 4' - 8.00" 6 5'- 4.00" 3-A I I 20'- 7.38" 5 I -1----1--1------------ 3 ' - 1 1 . 3 2 " ,- 3'- 6.00" 2'-0.00" 0-- --1--1'---------- 0 ' - 7 . 0 0 " FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD. ALL CROSS SECTION VIEWS AND ORIENTATION REFERENCES ARE FROM SMALL END OF THE TUBE. ALIGN WITH FLATS AT SMALL END UNLESS OTHERWISE NOTED. 4 3-A 2 1-A NOTES: R1. 06" TYP i FLAT 1. NOTE FLAT ORIENTATION 1-1 i FLAT (S) IAI 2 I BI 2. 8 MARK ON EXTERIOR OF THE~~ 2 1 12 SHAFT AN APPROXIMATELY I'--. 03. 00" DOT WITH BLUE "- ~ PAINT OR MARKER. ~~.--'-+---........,U FLATS #6 S. #12. *AFTER GALVANIZING* VIEW A-A ~D==E=T::::'.:A :::I L::::::::::1::::'.:::::'.:=====::::::H A::::'.:N:::'.::G".::"I'.:=N:::::'.G=::::::S:;::L::::O T:'.:::====~ ~D::'.'.'.E:'.:::T::::'.:A :::I L:::::::::'.2'.:=::::'.:l=====:'.:::V A::::'.:L::::M::::::O::=N::::'.:T=::::'.:M:;::'.:A::::'.:R I<::'.::====~ I II OF FLAT (S) II OF FLAT (S) I 1 1 NOTE: I ' ' I 2.00" LONG WELD 0.25" HIGH i OF WELD BEAD AND FLAT BEAD CENTER OF GRAVITY IS AN APPROXIMATE LOCATION. THE CALCULATION DOES NOT ACCOUNT FOR WELD MATERIAL OR MATERIAL SUBSTITUTIONS. DETAIL 5 CENTER OF GRAVITY ,,... '-/ NOTES: i OF TAG I (A) (BBBBBBB) - (C) (OODDDD) - (E) MAXIMUM SLIP STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE REQUIRED INFORMATION SHOWN IN THIS DETAIL PER WORK INSTRUCTION WI-11.02. A= MANUFACTURING SITE (ONE CHARACTER) B = VALMONT PART NUMBER (SEVEN CHARACTERS) C = FABRICATION SEQUENCE NUMBER (ONE OR MORE CHARACTERS) □ =VALMONT ORDER NUMBER (SIX CHARACTERS) E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE CHARACTERS) DETAIL 6 I VALMONT ID TAG - I TYPE I i FLAT (S) I DIMENSION AIJACKINGI 4,10 I 30.00" 0----- ----4-----. i NUT I DIMENSION DRILL 0.50" DIA HOLE AT i FLAT #1. ' SEE TABLE ) f i NUT 345170 i FLAT TYP; 0. 31 V ~ DETAIL 3 I JACKING/HANGING NUTS DETAIL 4 I MINIMUM SPLICE HOLE BILL OF MATERIAL (SHIP SEQ=O) VALMONT PART NO DESCRIPTION 2756207 SHAFT 345170 1.00" NUT QTY PER ASSY 8 2070063 IDENTIFICATION TAG l DUPLICATE DRAWING DISTRIBUTION I TMF SEC ASSY 32"B0 25"TD 39' -7"LG I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400 DRAWN I ENGR I DATE I SCALE t--+----+--+---+------------1 AM70 BKB l O l 711"";21 NONE P.A. CHK I SHOP CHK r---i-------t--r----t-------------p.16"'-M7'--'o~oc=-1~;!.c11,,,,1~2~- i<~M""'s:c,4='0~1"';c=-1'""'9;'-'2'4valmont -OTHER SPECIFICATIONS V' A O 1/19/21 AM7 KMS REVISED PER DRAFTING F-1,M-1,W-22 !LOCATION SYMBOL KEYi SHAFT INFO (MEASURED ACROSS FLATS) I REV CHK BY BY REVISION DESCRIPTION MATERIAL THICKNESS! WEIGHT 3, 130# I ,,,.-. LO CAT I ON I SHAPE I LENGTH I BASE OD I TOP OD IT APER I THK I ASTM I '7 REFERENCE I 12-SIDED I 39' -7 .00"I 32.05" I 24.89" I 0.181 I 0.250" I A572 I ORDER ND -1 487071 CUSTOMER DUKE I DESCRIPTION SECTION ASSEMBLY I DWG NO. 307137B 1 . 2. 3. LOCATION DIMENSION FROM FROM LARGE END SMALL END DETAIL 1::tt1i-~o---------~------~:===========O=' =-=0=·=0=0="===7=== - ~ _ O' - 6.00" 6 1'- 0.00" 5 ---........____ 2'-0.00" 3-B 28'- 2.75" 4 3'-6.00" I ,,,-f-----+------+-------< ,______,,,.-, - 3'- 2.47" 3-A O'- 7.00" FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD. ALL CROSS SECTION VIEWS AND ORIENTATION REFERENCES ARE FROM SMALL END OF THE TUBE. ALIGN WITH FLATS AT LARGE END UNLESS OTHERWISE NOTED. 2 1-A NOTES: R1. 06" TYP t FLAT 1. NOTE FLAT ORIENTATION I- t FLAT (5) IA 2 DRILL 0.50" DIA HOLE AT t FLAT #1. ~D==E=T::::::A:::IL::::::::::1::::'.:::::'.:=====::::::HA::::'.:N:::'.::G".::"I'.:=N:::::'.G=::::::S:=:L::::OT:'.:::====~ ~D::'.'.'.E:'.:::T::::'.:A'.".:'.IL:::::::::'.2'.:=::::'.:l==M::::'.:I::::N:::::'.I'.:=M:::::'.U::::'.:M=:::::S::::'.:PL'.'.'.:'.I'.'.::'.C'.;:'.'E'.:==H::::::O::=L:=:E=~ I G: OF FLAT (S) MARK ON EXTERIOR OF THE------ SHAFT AN APPROX I MA TEL Y I"--~ 1 12 03. 00" DOT WITH BLUE ~ PAINT OR MARKER. ~-.-+--~~..,.., FLATS #6 & #12. *AFTER GALVANIZING* VIEW A-A DETAIL 5 VALMONT MARK '-/ NOTES: t OF TAG I (A) (BBBBBBB) - (C) (DODDDD) - (E) I 1 STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE REQUIRED INFORMATION SHOWN IN THIS DETAIL PER WORK INSTRUCTION WI-11.02. A= MANUFACTURING SITE (ONE CHARACTER) B = VALMONT PART NUMBER (SEVEN CHARACTERS) C = FABRICATION SEQUENCE NUMBER (ONE OR MORE CHARACTERS) D = VALMONT ORDER NUMBER (SIX CHARACTERS) E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE CHARACTERS) DETAIL 6 I VALMONT ID TAG - I TYPE I t FLAT (S) I DIMENSION AIJACKINGI 4,10 I 30.00" BIHANGINGI 2 I 8.00" 0----- ----4-----. t NUT I DIMENSION ' SEE TABLE ) f t NUT 345170 t FLAT TYP; 0. 31 V ~ DETAIL 3 I JACKING/HANGING NUTS ___.l._ A /"f"lll7' A t FLATS 4 & 10 ---4--- t ti 11 NOTES: 1. TRIM STRAP AS NEEDED. I t FLATS l & 7 2. WELD STRAP 0.25" BELOW TOP. 3. INSTALL CAP PRIOR TO SHIPPING. □ ET AIL 7 I POLE CAP STRAP NOTE: I ' ' I I G: OF FLAT (5) I 1 2.00" LONG WELD 0.25" HIGH BEAD t OF WELD BEAD AND FLAT CENTER OF GRAVITY IS AN APPROXIMATE LOCATION. THE CALCULATION DOES NOT ACCOUNT FOR WELD MATERIAL OR MATERIAL SUBSTITUTIONS. DETAIL 4 I CENTER OF GRAVITY BILL OF MATERIAL (SHIP SEQ=O) VALMONT QTY DESCRIPTION PER PART NO ASSY 2756208 SHAFT l 345170 1.00" NUT 6 2070063 IDENTIFICATION TAG l 1613173 POLE CAP MTG STRAP l POST-FINISHING ATTACHMENTS SEE DETAIL (SI 7 (SHIP SEQ=2) 163475H POLE CAP 1000422 0. 75"xl. OO"LG BOLT l 142056 0. 75" DIA FLATWSHR l DUPLICATE DRAWING DISTRIBUTION I TMF SEC ASSY 26" BO 1 7 "TD 52' -11 "LG I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400 DRAWN I ENGR I DATE I SCALE t--+----+--+--+-------------1 AM70 BKB1 01711?21 NONE P.A. CHK I SHOP CHK r---i-------t--r----t------------p.16!.:!.M7'--'o~oc=-1~; !.c11,,,,1~2~· i<~M""'s:c,4 ='0~1"';c=-1 '""'9;'-'2'4 valmont -OTHER SPECIFICATIONS V' A O 1/19/21 AM7 KMS REVISED PER DRAFTING F-1,M-1,W-22 !LOCATION SYMBOL KEYi SHAFT INFO (MEASURED ACROSS FLATS) I REV CHK BY BY REVISION DESCRIPTION MATERIAL THICKNESS! WEIGHT 2,764# I ,,,.-. LO CAT I ON I SHAPE I LENGTH I BASE OD I TOP OD IT APER I THK I ASTM I '7 REFERENCE I 12-SIDED 152' -11.00"I 26.08" I 16.51" I 0.181 I 0.219" I A572 I ORDER ND· 1 487071 CUSTOMER DUKE I DESCRIPTION SECTION ASSEMBLY I DWG NO. 307137C Valmont taper per section: 0.181 in/ft Overall taper: 0.174142857 in/ft Section Length (ft) Elev (ft) Diameter (in) Thickness (in) Valmont Min. Lap Splice per C 52.916667 120 16.51 0.219 Lap Splice TIA-222-H Sect. 4.9.7.1. C 67.08333 26.08 0.219 50 in 38.463 in B 39.583333 71.25 24.89 0.25 B 31.66667 32.05 0.25 58 in 47.325 in A 56.5 36.5 30.67 0.281 A 0 37.2765 0.281 Pole AVG Embed. Diam. 39.08325 in A -20 40.89 0.281 Pole AVG Embed. Diam. 3.256938 ft Per TIA-222-H-1 Section 9.4.3.1: For gravel backfill, it shall be permissible to consider a constant effective foundation diameter over the embedment depth equal to the average of the mid-depth diameter of the pole and the outer *Drill Bit Diam. for Embed. 4.5 ft diameter of the gravel annulus, not to exceed the pole base Thus, the effective Fdn Diam. 3.878469 ft diameter plus 9 in. [229 mm]. *Note: East Construction uses the pole bottom diameter + 6in of gravel on each side to select their drill bit diameter. Example: 40.89+6+6=52.89 inch However, drill bits only come in half foot sizes so a 54" bit would be used in this example. 07/11/2025 140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub Job Number: 24131425.STR.3889 Page 8 tnxTower Report - version 8.3.1.2 APPENDIX C ADDITIONAL CALCULATIONS AV Report File: TIA-222 Revison: Tower Type: Check Pier Capacity only at location of Max Moment? No Location: Soil Lateral Check Compression Uplift Comp. Uplift 4.31 - 1359 1.31 - 17 1422.41 - 22 101.9% - Soil Vertical Check Compression Uplift 84.07 - 3 ksi 145.33 - 60 ksi . 9.21 - 40 ksi 229.40 - 26.21 - 11.4% - 20 ft Embedded Pole Interaction Compression Uplift 0 ft 3.28 - 1417.38 - 1565.91 - 3.878469 ft 91.4% - 27 Reinforced Concrete Shear Compression Uplift - - 3 in - - 4 - - in - - in 6 # of Layers 6 121 FALSE 1 0 4 4 100 150 0 27 0.000 0.000 0.00 0.00 FALSE 2 4 6 2 105 150 0 27 0.000 0.000 0.20 0.00 FALSE 3 6 8 2 42.6 87.6 0 29 0.000 0.000 0.30 0.30 FALSE 4 8 12 4 57.6 87.6 0 30 0.000 0.000 0.50 0.50 FALSE 5 12 17 5 57.6 87.6 0 30 0.000 0.000 0.70 0.70 FALSE 6 17 20 3 62.6 87.6 0 30 0.000 0.000 0.90 0.90 15 Pier Diameter Rebar Quantity Rebar Cage Diameter Rebar Quantity Tie Spacing Embedded Pole Foundation Site Name: Monopole Applied Loads Material Properties Pier Design Data H Sumter Wedgefield Moment (kip-ft) Axial Force (kips) Shear Force (kips) Concrete Strength, f'c: Rebar Strength, Fy: Tie Yield Strength, Fyt: Cohesionless Cohesionless Cohesionless Cohesionless Cohesionless Ultimate Skin Friction Uplift Override (ksf) Critical Shear Capacity Rating Skin Friction (kips) Weight of Concrete (kips) Rating Critical Shear (kip) End Bearing (kips) Axial (kips) Critical Depth (ft from TOC) Calculated Ultimate Skin Friction Uplift (ksf) Calculated Ultimate Skin Friction Comp (ksf) Ultimate Skin Friction Comp Override (ksf) Soil Profile Soil TypeSPT Blow Count Ult. Net Bearing Capacity (ksf) γsoil (pcf) γconcrete (pcf) Critical Depth (ft from TOC) 101.9%Soil Interaction Rating Rebar 2, Fy Override (ksi) Rebar 3, Fy Override (ksi) Depth Cohesionless Layer Top (ft) Bottom (ft) Thickness (ft) Groundwater Depth Cohesion (ksf) Angle of Friction (degrees) Rebar Size Pier Section 1 Dv=0 (ft from TOC) Soil Safety Factor Max Moment (kip-ft) Rating Ext. Above Grade Critical Moment (kip-ft) Critical Moment Capacity Rating From 0' below grade to 20' below grade Rebar Size Clear Cover to Ties Tie Size D:\ETS\SE PROJECTS\2024\07 JUL\Frankfort 230 (INFRA2)_24125456.STR.7253 r Analysis\Analysis\Tower\Frankfort 230 (INFRA2).eri.rtf 91.4%Structural Foundation Rating Total Capacity (kips) Analysis Results Rebar & Pier Options Embedded Pole Inputs Belled Pier Inputs Version 5.0.3 Site Name: Sumter Wedgefield Encased in Concrete: No Number of Sides: 12 Yield Strength (ksi): 65 Thickness (in): 0.281 Bend Radius (in): 0.4215 Taper Factor (in/ft): 0.1809 Depth from Grade (ft): 6.01 Diameter (in): 38.36 Axial Demand (kip): 19.87 Axial Capacity (kip): 2055.10 Rating: 1.0% Depth from Grade (ft): 3.23 Diameter (in): 37.86 Flexural Demand (kip-ft): 1416.91 Flexural Capacity (kip-ft): 1565.38 Rating: 90.5% Depth from Grade (ft): 3.28 Diameter (in): 37.8656 Axial Demand (kip): 18.84 Axial Capacity (kip): 2044.17 Flexural Demand (kip-ft): 1417.38 Flexural Capacity (kip-ft): 1565.91 Version Rating: 91.4% Structural Rating: 91.4% Version 5.0.3 Maximum Interaction Rating Maximum Flexural Rating Maximum Axial Rating SUPPLEMENTAL EMBEDDED POLE REPORT Embedded Pole Properties ASCE Hazards Report Address: No Address at This Location Standard: ASCE/SEI 7-16 Latitude: 33.912755 Risk Category: III Longitude: -80.393316 Soil Class: D - Default (see Section 11.4.3) Elevation: 183.87499719305484 ft (NAVD 88) Wind Results: Wind Speed 133 Vmph 10-year MRI 75 Vmph 25-year MRI 84 Vmph 50-year MRI 92 Vmph 100-year MRI 99 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1C and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Fri Jul 11 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 3% probability of exceedance in 50 years (annual exceedance probability = 0.000588, MRI = 1,700 years). Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings need not be protected against wind-borne debris. Page 1 of 3https://ascehazardtool.org/ Fri Jul 11 2025 SS : 0.384 S1 : 0.128 F a : 1.493 F v : 2.343 SMS : 0.573 SM1 : 0.301 SDS : 0.382 SD1 : 0.201 T L : 8 PGA : 0.219 PGA M : 0.302 F PGA : 1.381 Ie : 1.25 Cv : 0.956 Seismic Design Category: D Design Response Spectrum S (g) vs T(s)a MCE Response SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum S (g) vs T(s)a MCE Vertical Response SpectrumR S (g) vs T(s)a Seismic D - Default (see Section 11.4.3)Site Soil Class: Results: Data Accessed: Fri Jul 11 2025 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. Page 2 of 3https://ascehazardtool.org/ Fri Jul 11 2025 Ice Results: Data Source: Date Accessed: Ice Thickness: 1.00 in. Concurrent Temperature: 15 F Gust Speed 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Fri Jul 11 2025 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/ Fri Jul 11 2025 PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION TITLE PAGE T-1 SITE N NW W SW S SE E NE NNW WNW WSW SSWSSE ESE ENE NNE GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, THEREFORE HANDICAP ACCESS IS NOT REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. SCOPE OF WORK INSTALLATION OF A PROPOSED 120'± MONOPOLE, WITH NEW MOUNTED CAMBIUM 5GHz EQUIPMENT, WITHIN AN EXISTING DUKE ENERGY OWNED ELECTRICAL SUBSTATION. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE FOLLOWING CODES: SITE MAPSITE PHOTO ·2021 S.C. BUILDING CODE (2021 IBC W/ AMENDMENTS) ·2021 S.C. EXISTING BUILDING CODE (2021 IEBC W/ AMENDMENTS) ·2021 S.C. FIRE CODE (2021 IFC W/ AMENDMENTS) ·2021 S.C. FUEL GAS CODE (2021 IFGC W/ AMENDMENTS) ·2021 S.C. MECHANICAL CODE (2021 IMC W/ AMENDMENTS) ·2021 S.C. PLUMBING CODE (2021 IPC W/ AMENDMENTS) ·2020 S.C. ELECTRICAL CODE (2020 NEC W/ AMENDMENTS) ·2021 S.C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC) SUBSTATION NAME: SUMTER WEDGEFIELD ROAD 230 SUB SUBSTATION TELECOM NUMBER: SCSMT017 SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 LATITUDE & LONGITUDE: N 33° 54' 45.90" , W 80° 23' 35.90" SUBSTATION TRANSMISSION NUMBER: T3985 PROJECT TEAM SURVEYOR NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: JMT. 2154 N. CENTER STREET SUITE A-101 NORTH CHARLESTON, SC 29406 RANDALL L. STEPP (843) 974-5650 CIVIL ENGINEER NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: ENGINEERED TOWER SOLUTIONS 3227 WELLINGTON COURT RALEIGH, NC 27615 CHRISTOPHER G. PLY, P.E., S.E. (919) 782-2710 STRUCTURAL ENGINEER NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: ENGINEERED TOWER SOLUTIONS 3227 WELLINGTON COURT RALEIGH, NC 27615 CHRISTOPHER G. PLY, P.E., S.E. (919) 782-2710 ELECTRICAL ENGINEER NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: ENGINEERED TOWER SOLUTIONS 3227 WELLINGTON COURT RALEIGH, NC 27615 CHRISTOPHER G. PLY, P.E., S.E. (919) 782-2710 GEOTECHNICAL ENGINEER NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: ENGINEERED TOWER SOLUTIONS 3227 WELLINGTON COURT RALEIGH, NC 27615 FREDERIC G. BOST, P.E. (919) 782-2710 POLE MANUFACTURER NAME: ADDRESS: CITY, STATE, ZIP: CONTACT: PHONE: VALMONT INDUSTRIES 15000 VALMONT PLAZA OHAHA, NEBRASKA, 98154 CUSTOMER SERVICE 1(402) 963-1000 SITE SUMMARY SITE TYPE:NEW CONSTRUCTION STRUCTURE TYPE:MONOPOLE STRUCTURE OWNER:DUKE ENERGY SITE APPLICANT:DUKE ENERGY STRUCTURE HEIGHT (AGL):120'± OCCUPANCY TYPE:UTILITY & MISCELLANEOUS (U) STRUCTURE LATITUDE (NAD 83):N 33° 54' 45.90" (33.912755°) STRUCTURE LONGITUDE (NAD 83):W 80° 23' 35.90" (-80.393316°) PROPERTY OWNER:DUKE ENERGY JURISDICTION:CITY OF SUMTER COUNTY:SUMTER PARCEL ID:2060002010 GROUND ELEV. (NAVD):183.7' INDEX OF SHEETS T-1TITLE PAGE 1 OF 1SURVEY GN-1GENERAL NOTES I GN-2GENERAL NOTES II GN-3GENERAL NOTES III C-1.0OVERALL PROPERTY PLAN C-1.1SUBSTATION COMPOUND PLAN C-1.2TRANSMISSION GROUNDING PLAN C-1.3TRANSMISSION CONDUIT PLAN C-2COMMUNICATION POLE ELEVATION & ANTENNA PLAN C-3.1 DETAILS I C-3.2 DETAILS II C-3.3 DETAILS III C-3.4 DETAILS IV SITE SITE 2154 N. CENTER STREET SUITE A-101 NORTH CHARLESTON, SC 29406 843-974-5650 P: (843) 556-2624 | www.jmt.com PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION GENERAL NOTES I GN-1 1. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND CARRIER PROJECT SPECIFICATIONS. 2. GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND SHALL CONFIRM THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED IN THESE DRAWINGS. 6. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISHED SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN IN THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 9. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 10.GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 11.ERECTION SHALL BE DONE IN WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED IN THE DRAWINGS. 12.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 13.THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 14.CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK. 15.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 16.THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 17. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 18.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 19.THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 20.THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NO LESS THAN 2-A OR 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 21. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 22. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 23. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE COMMUNICATION POLE, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 24. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 25. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 26. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION. 27. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 28. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 29. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 30. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 31. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED). 32. STRUCTURE IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY CARRIER TECHNICIANS. 33. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 34. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST CARRIER GROUNDING STANDARD. IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. 35. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 36. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 37. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 38. ALL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA STANDARDS AND REQUIREMENTS. 1. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT-DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS NOTED OTHERWISE. 2. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC-COATING (HOT-DIP) ON IRON AND STEEL HARDWARE", UNLESS NOTED OTHERWISE. 3. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 4. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND SHALL BE TORQUED TO MANUFACTURER'S RECOMMENDATIONS. 5. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR INSTALLATION AND GROUNDING. 6. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR SHALL CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE PLUMB. ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH AND BE ORIENTED WITHIN +/- 5% AS DEFINED BY THE RFDS. ANTENNA DOWNTILTS SHALL BE WITHIN +/- 0.5% AS DEFINED BY THE RFDS. REFER TO ND-00246. 7. CONTRACTOR SHALL VERIFY THE DOWN-TILT OF EACH ANTENNA WITH A DIGITAL LEVEL. 1. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH. 2. ALL RF CONNECTIONS, GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE A TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF THE CONNECTION. 3. RF CONNECTION BOTH SIDES OF THE CONNECTOR. 4. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE THREADS TO THE SOLID SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR, ANTENNA BRACKET METAL. 5. ALL 2', 3' & 4' ANTENNA HARDWARE SHALL BE TIGHTENED TO 9 LB-FT (12 NM). 6. ALL 6' ANTENNA HARDWARE SHALL BE TIGHTENED TO 43 LB-FT (58 NM). 7. ALL GROUNDING HARDWARE SHALL BE TIGHTENED UNTIL THE LOCK WASHER COLLAPSES AND THE GROUNDING HARDWARE IS NO LONGER LOOSE. 8. ALL DIN TYPE CONNECTIONS SHALL BE TIGHTENED TO 18-22 LB-FT (24.4-29.8 NM). 9. ALL N TYPE CONNECTIONS SHALL BE TIGHTENED TO 15-20 LB-IN (1.7-2.3 NM). GENERAL NOTESGENERAL NOTES (CONTINUED)ANTENNA MOUNTING NOTES TORQUE REQUIREMENTS 1. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. 2. CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. REFER TO "ANTENNA SYSTEM LABELING STANDARD" ND-00027 LATEST VERSION. 3. ALL JUMPERS TO THE ANTENNAS SHALL BE 1/2" DIA. LMR 400 AND SHALL NOT EXCEED 3'-0". 4. ALL COAXIAL CABLE SHALL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE, IN AN APPROVED MANNER, AT DISTANCES NOT TO EXCEED 4'-0" OC. 5. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND ALL OTHER EQUIPMENT. 6. CONTRACTOR SHALL WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATING TAPE. WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS. COAXIAL CABLE NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION. 2. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 3. CONTRACTOR SHALL REFERENCE THE STRUCTURAL ANALYSIS/DESIGN DRAWINGS FOR DIRECTIONS ON CABLE DISTRIBUTION/ROUTING. GENERAL CABLE AND EQUIPMENT NOTES PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION GENERAL NOTES II GN-2 1. ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED, EXCEPT THE RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE MADE. BUTYL TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH TURN AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE SMOOTH WITHOUT BUCKLING. BUTYL BLEEDING IS NOT ALLOWED. 2. IF REQUIRED TO PAINT ANTENNAS AND/OR COAX: 2.1. TEMPERATURE SHALL BE ABOVE 50° F. 2.2. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD. 2.3. FOR REGULATED TOWERS, FAA/FCC APPROVED PAINT IS REQUIRED. 2.4. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS. 3. ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR. TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION. 4. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATION & RECOMMENDATIONS.NO BOLT THREADS TO PROTRUDE MORE THAN 1-1/2" [.038M]. 5. 90 SHORT SWEEPS UNDER ANTENNA ARM. ALL CABLES MUST ONLY TRANSITION ON THE INSIDE OR BOTTOM OF ARMS (NO CABLE ON TOP OF ARMS). 6. USE 90 CONNECTOR AT CABLE CONNECTION TO ANTENNAS. 7. PLACE GPS ON ARM WITH SOUTHERN SKY EXPOSURE AT MINIMUM 6' [1.83] FROM TRANSMIT ANTENNA, WHICH IS 24" [.61M] AWAY FROM CENTER OF POLE. 8. USE 1/2" [.013M] CABLE ON ANTENNAS UNLESS OTHERWISE SPECIFIED. 9. FILL VOID AROUND CABLES AT CONDUIT OPENING WITH FOAM SEALANT TO PREVENT WATER INTRUSION. GENERAL CABLE AND EQUIPMENT NOTES FIBER & POWER CABLE MOUNTING FOUNDATION GENERAL NOTES 1. ALL WELDING SHALL BE IN ACCORDANCE WITH THE AWS D1.1/D1.1M: 2015 "STRUCTURAL WELDING CODE-STEEL". 2. ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS. 3. CONTRACTOR SHALL RETAIN AN AWS CERTIFIED WELD INSPECTOR TO PERFORM VISUAL INSPECTIONS ON FIELD WELDS. A LETTER AND REPORT SHALL BE ISSUED TO THE CONTRACTOR. CONTRACTOR SHALL SUBMIT LETTER AND REPORT TO TOWER OWNER. 4. GRIND THE SURFACE ADJACENT TO THE WELD FOR A DISTANCE OF 2" MINIMUM ALL AROUND. GRIND THE SURFACE OF THE ROD TO BE INSTALLED FOR A DISTANCE OF 2" MINIMUM ALL AROUND THE AREA TO BE WELDED. ENSURE BOTH AREAS ARE 100% FREE OF ALL GALVANIZING. SURFACES TO BE WELDED SHALL BE FREE FROM SCALE, SLAG, RUST, MOISTURE, GREASE OR ANY OTHER FOREIGN MATERIAL THAT WOULD PREVENT PROPER WELDING. 5. DO NOT WELD IF THE TEMPERATURE OF THE STEEL IN THE VICINITY OF THE WELD AREA IS BELOW 0°F. WHEN THE TEMPERATURE IS BETWEEN 0°F AND 32°F, PREHEAT AND MAINTAIN THE STEEL IN THE VICINITY OF THE WELD AREA AT 70°F DURING THE WELDING PROCESS. 6. DO NOT WELD ON WET OR FROST-COVERED SURFACES & PROVIDE ADEQUATE PROTECTION FROM HIGH WINDS. 7. FOR ALL WELDING, USE E70XX ELECTRODES. 8. AFTER FINAL INSPECTION, THE AREA OF THE WELDS, THE INSTALLATION AND ALL SURFACES DAMAGED BY WELDING OR GRINDING SHALL RECEIVE A COLD-GALVANIZED COATING. THIS COATING SHALL BE APPLIED BY BRUSH. THE GALVANIZING COMPOUND SHALL CONTAIN A MINIMUM OF 95% ± PURE ZINC. THE FINISHED COATING SHALL BE A MINIMUM THICKNESS OF 3 MILS. FOUNDATION NOTES BOLT TIGHTENING PROCEDURE WELDING NOTES STRUCTURAL STEEL NOTES FOUNDATION NOTES (CONTINUED) 1. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE AISC SPECIFICATION FOR MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN, 15TH EDITION. 2. UNLESS OTHERWISE NOTED, ALL STRUCTURAL ELEMENTS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: STRUCTURAL STEEL: ·ANGLE: ASTM A36 ·PIPE/TUBE: ASTM A500-50 ·PLATE: ASTM A36 A. ALL BOLTS, ASTM A325 TYPE I GALVANIZED HIGH STRENGTH BOLTS. B. ALL U-BOLTS, ASTM A193 GRADE B7 C. ALL NUTS, ASTM A563 CARBON AND ALLOY STEEL NUTS. D. ALL WASHERS, ASTM F436 HARDENED STEEL WASHERS. 3. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL FABRICATOR IN ACCORDANCE WITH AISC SPECIFICATION FOR MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN, 15TH EDITION. 4. HOLES SHALL NOT BE FLAME CUT THRU STEEL UNLESS APPROVED BY THE ENGINEER. 5. HOT-DIP GALVANIZE ALL ITEMS UNLESS OTHERWISE NOTED, AFTER FABRICATION WHERE PRACTICABLE. GALVANIZING: ASTM A123, ASTM, A153/A153M OR ASTM A653/A653M, G90, AS APPLICABLE. 6. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A780 OR BY APPLICATION OF STICK OR THICK PASTED MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED, WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS IN STICK OR PASTED; SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL. 7. A NUT LOCKING DEVICE SHALL BE INSTALLED ON ALL PROPOSED AND/OR REPLACED BOLTS. 8. ALL PROPOSED AND/OR REPLACED BOLTS SHALL BE OF SUFFICIENT LENGTH TO EXCLUDE THE THREADS FROM THE SHEAR PLANE. 9. ALL PROPOSED AND/OR REPLACED BOLTS SHALL BE OF SUFFICIENT LENGTH SUCH THAT THE END OF THE BOLT BE AT LEAST FLUSH WITH THE FACE OF THE NUT. IT IS NOT PERMITTED FOR THE BOLT END TO BE BELOW THE FACE OF THE NUT AFTER TIGHTENING IS COMPLETED. 10. GALVANIZED ASTM A325 BOLTS SHALL NOT BE REUSED. 1. CONNECTION BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED AND TIGHTENED AS PER SECTION 8.2 OF THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS, LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. THE INSTALLATION PROCEDURE IS PARAPHRASED AS FOLLOWS: 2. FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONE OF THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4. 8.2.1 TURN-OF-THE-NUT TIGHTENING. BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT TO A SNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL ALL THE BOLTS ARE SIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED. FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BE TIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE. DURING THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOT TURNED BY THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT IN A MANNER THAT WILL MINIMIZE RELAXATION OF PREVIOUSLY PRETENSIONED BOLTS. 3. TIGHTEN CONNECTION BOLTS BY AISC - "TURN OF THE NUT" METHOD, USING THE CHART BELOW. BOLT LENGTHS UP TO AND INCLUDING FOUR DIA. 12" BOLTS UP TO AND INCLUDING 2.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT 58" BOLTS UP TO AND INCLUDING 2.5 INCH LENGTH +13 TURN BEYOND SNUG TIGHT 34" BOLTS UP TO AND INCLUDING 3.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT 78" BOLTS UP TO AND INCLUDING 3.5 INCH LENGTH +13 TURN BEYOND SNUG TIGHT 1" BOLTS UP TO AND INCLUDING 4.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT BOLT LENGTHS OVER FOUR DIA. BUT NOT EXCEEDING EIGHT DIA. 12" BOLTS 2.25 TO 4.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT 58" BOLTS 2.75 TO 5.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT 34" BOLTS 3.25 TO 6.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT 78" BOLTS 3.75 TO 7.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT 1" BOLTS 4.25 TO 8.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT 4. ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1 OF THE SPECIFICATION. 1. FOUNDATION INSTALLATION SHALL BE SUPERVISED BY PERSONNEL KNOWLEDGEABLE AND EXPERIENCED WITH THE PROPOSED FOUNDATION TYPE. CONSTRUCTION SHALL BE IN ACCORDANCE WITH GENERALLY ACCEPTED PRACTICES AND IN A GOOD WORKMANLIKE MANNER. 2. CONTRACTOR TO VERIFY DIMENSIONS WITH ORIGINAL TOWER DRAWINGS. ETS SHALL BE NOTIFIED OF ANY DISCREPANCIES BETWEEN FIELD MEASURED DIMENSIONS AND ORIGINAL TOWER DRAWINGS. 3. FOUNDATION DESIGN MODIFICATIONS MAY BE REQUIRED IN THE EVENT THE DESIGN PARAMETERS ARE NOT APPLICABLE FOR THE SUBSURFACE CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 4. FOR FOUNDATION TOLERANCES, SEE ORIGINAL TOWER DRAWINGS. 5. THE FOUNDATION MODIFICATION DESIGN IS IN ACCORDANCE WITH GENERALLY ACCEPTED PROFESSIONAL ENGINEERING PRINCIPLES AND PRACTICES WITHIN THE LIMITS OF SUBSURFACE DATA PROVIDED. 6. THE FOUNDATION DEPTH INDICATED IS BASED ON THE GRADE LINE DESCRIBED IN THE REFERENCE GEOTECHNICAL REPORT. FOUNDATION MODIFICATION MAY BE REQUIRED IN THE EVENT CUT OR FILL OPERATIONS HAVE TAKEN PLACE SUBSEQUENT TO THE GEOTECHNICAL INVESTIGATION. 7. THE FOUNDATION DESIGN ASSUMES THAT INSTALLATION METHODS WILL INCORPORATE THE PROCEDURES RECOMMENDED IN THIS REPORT. 8. THE FOUNDATION DESIGN ASSUMES FIELD INSPECTIONS WILL BE PERFORMED TO VERIFY THAT CONSTRUCTION MATERIALS, INSTALLATION METHODS, AND ASSUMED DESIGN PARAMETERS ARE ACCEPTABLE BASED ON THE CONDITIONS AT THE SITE. 9. THE FOUNDATION DESIGN ASSUMES NO CONSTRUCTION JOINTS, HOWEVER, CONSTRUCTION JOINTS SHALL BE PERMITTED UPON APPROVAL BY THE OWNER/ENGINEER. EXCAVATION 1. WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND SAFETY REGULATIONS. PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION, AND UTILITIES SHALL BE ESTABLISHED PRIOR TO BEGINNING WORK. 2. THE SIDES OF THE EXCAVATION SHALL BE ROUGH AND FREE OF CUTTINGS. 3. LOOSE MATERIAL TO BE REMOVED FROM THE BOTTOM OF EXCAVATION PRIOR TO CONCRETE PLACEMENT. REINFORCING STEEL 1. THE REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615, GRADE 60. IT SHALL BE DEFORMED AND SPLICES SHALL NOT BE ALLOWED UNLESS OTHERWISE NOTED. 2. WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENTS. 3. REINFORCING CAGES SHALL BE BRACED TO RETAIN PROPER DIMENSIONS DURING HANDLING AND THROUGHOUT PLACEMENT OF CONCRETE. WHEN TEMPORARY CASING IS UTILIZED, BRACING SHALL BE ADEQUATE TO RESIST FORCES OCCURRING FROM FLOWING CONCRETE DURING CASING EXCAVATION. 4. SPACERS SHALL BE ATTACHED INTERMITTENTLY THROUGHOUT THE ENTIRE LENGTH OF TIEBACK REINFORCING TO INSURE CONCENTRIC PLACEMENT OF CASING IN EXCAVATIONS. 5. MINIMUM CONCRETE COVER FOR REINFORCEMENT SHALL BE 3" UNLESS OTHERWISE NOTED. APPROVED SPACERS SHALL BE USED TO INSURE A 3" MINIMUM COVER FOR REINFORCEMENT. 6. THE CONCRETE COVER FROM THE TOP OF THE FOUNDATION TO THE ENDS OF THE VERTICAL REINFORCEMENT SHALL NOT BE LESS THAN 3". CONCRETE 1. WORK SHALL BE IN ACCORDANCE WITH THE ACI 318-14, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY". 2. THE CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 3000-PSI IN 28 DAYS. 3. ANY CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED AS REQUIRED BY ACI 318-14. 4. PROPORTIONS OF CONCRETE MATERIALS SHALL BE SUITABLE FOR THE INSTALLATION METHOD UTILIZED AND SHALL RESULT IN DURABLE CONCRETE FOR RESISTANCE TO LOCAL ANTICIPATED AGGRESSIVE ACTIONS. THE DURABILITY REQUIREMENTS OF ACI 318-14 SHALL BE SATISFIED BASED ON THE CONDITIONS EXPECTED AT THE SITE. 5. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE MATERIALS, INFILTRATION OF WATER OR SOIL, AND OTHER OCCURRENCES THAT MAY DECREASE THE STRENGTH OR DURABILITY OF THE FOUNDATION. 6. FREE FALL CONCRETE MAY BE USED PROVIDED FALL IS VERTICAL DOWN WITHOUT HITTING THE SIDES OF THE EXCAVATION, FORMWORK, REINFORCING BARS, FORM TIES, CAGE BRACING, OR OTHER OBSTRUCTIONS. UNDER NO CIRCUMSTANCES SHALL CONCRETE FALL THROUGH WATER. 7. THE MAXIMUM SIZE OF THE AGGREGATE SHALL NOT EXCEED A SIZE SUITABLE FOR THE INSTALLATION METHODS UTILIZED OR 2/3-CLEAR DISTANCE BEHIND OR BETWEEN REINFORCING. THE MAXIMUM SIZE MAY BE INCREASED TO 2/3-CLEAR DISTANCE PROVIDED WORKABILITY AND METHODS OF CONSOLIDATION SUCH AS VIBRATING WILL PREVENT HONEYCOMBS AND VOIDS. FINISHING 1. THE TOP OF THE FOUNDATION SHALL BE SLOPED TO DRAIN WITH A FLOATED FINISH. 2. THE EXPOSED EDGES OF THE CONCRETE SHALL BE CHAMFERED 1" X 1". EPOXY NOTES 1. EPOXY AGENTS SHOULD BE ALLOWED TO CURE ACCORDING TO MANUFACTURERS RECOMMENDATIONS. 2. ALL HARDWARE ASSEMBLY AND MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED; ANY CONTRADICTION BETWEEN THE MANUFACTURER'S RECOMMENDATIONS AND THESE DRAWINGS ARE TO BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER AND OWNER. 3. ANY CONTRACTOR INSTALLING ADHESIVE ANCHORING SYSTEMS SHALL BE TRAINED, IN PERSON BY A MANUFACTURER'S REPRESENTATIVE, ON THE PROPER INSTALLATION TECHNIQUES. THIS TRAINING SHALL INCLUDE PROPER DRILLING, HOLE CLEANING, AND INSTALLATION METHODS FOR THE ADHESIVE ANCHORING SYSTEM AND CONSTRUCTION CONDITIONS ON THIS PROJECT. ALL TRAINING TO BE CONDUCTED PRIOR TO CREWS STEPPING ON SITE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT MANUFACTURER REPRESENTATIVE TO SET UP TRAINING, ETS IS NOT RESPONSIBLE FOR ANY COST OCCURRED FOR OR DURING ADHESIVE ANCHORING SYSTEM TRAINING. SOIL COMPACTION 1. SUBGRADE PREPARATION 1.1. SHAPE TOP OF SUBGRADE TO THE LINES AND GRADES SHOWN ON THE DRAWINGS. 1.2. MAINTAIN TOP OF SUBGRADE IN A FREE-DRAINING CONDITION. 1.3. DO NOT STOCKPILE MATERIALS ON TOP OF SUBGRADE UNLESS AUTHORIZED BY CONSTRUCTION MANAGER. 1.4. FOR SUBGRADES CONSISTING OF IN-PLACE NATIVE SOILS, SOILS SHALL BE FREE OF CUTTING AND OTHER LOOSE MATERIAL AND SHALL MEET THE MINIMUM BEARING CAPACITY REQUIREMENTS NOTES UNDER SOIL STRENGTH 1.5. FOR SUBGRADES CONSISTING OF PLACED STRUCTURAL FILL, STRUCTURAL FILL SHOULD BE PLACED IN 6 INCH LIFTS AND COMPACTED TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS OBTAINED BY THE STANDARD PROCTOR METHOD 1.6. CONSTRUCT TOP OF SUBGRADE WITHIN ONE INCH OF ESTABLISHED GRADE AND CROSS-SECTION. SOIL STRENGTH 1. FOUNDATION DESIGN IS BASED ON A 2000 PSF SOIL BEARING CAPACITY. IF OTHER CONDITIONS EXIST, FOUNDATION SHALL BE REDESIGNED. CONTRACTOR SHALL HAVE SOIL BEARING CAPACITY VERIFIED BY A LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER PRIOR TO INITIATION OF CONSTRUCTION ACTIVITIES. 1. FOR VERTICAL RUNS: ON TOWERS OR POLES, ALWAYS UNREEL THE SPOOL FROM THE TOP DOWN. ENSURE NO STRAIN IS PLACED ON THE FIRST 3 FEET OF THE CABLE, AND THAT THE CABLE IS SUPPORTED EVERY THREE FEET VERTICALLY. NEVER ALLOW THE CABLE TO EXPERIENCE THE STRAIN OF THE CABLE SPOOL WEIGHT. ANY BENDS SHALL BE SUPPORTED DIRECTLY ABOVE AND BELOW THE BEND. THE BOTTOM BEND SHALL HAVE A DRIP LOOP WITH A MINIMUM ONE FOOT BEND RADIUS AT 120°. IT IS RECOMMENDED THE FIBER BE TESTED BEFORE AND AFTER INSTALLATION FOR NO GREATER THAN .02 dB LOSS. PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION GENERAL NOTES III GN-3 ABBREVIATIONSLINETYPES ABC AGGREGATE BASE COURSE ABS AIR BREAK SWITCH A.C. ASBESTOS CEMENT A/C AIR CONDITIONING A.D. AREA DRAIN A.F.F. ABOVE FINISHED FLOOR ALT. ALTERNATE ALUM. ALUMINUM AMP. AMPERES A.O. ACCESS OPENING APPROX. APPROXIMATELY ARCH. ARCHITECTURAL ASPH. ASPHALT A.T..P. ANTI-TERRORISM FORCE PROTECTION A.W.W.A. AMERICAN WATER WORKS ASSOCIATION BLDG. BUILDING BM. BENCH MARK BOC BACK OF CURB BOL BOLLARD BRG. BEARING BVC BEGIN VERTICAL CURVE BVCE BEGIN VERTICAL CURVE ELEVATION BVCS BEGIN VERTICAL CURVE STATION C&G CURB AND GUTTER CATV CABLE TELEVISION CAP. CAPACITY C.B. CATCH BASIN CBL CABLE CEM. CEMENT CER. CERAMIC C.F.M. CUBIC FEET/MINUTE C.F.S. CUBIC FEET/SECOND C.I. CURB INLET C.I.P. CAST IRON PIPE CIRC. CIRCULATING C.A. CONSTRUCTION JOINT/CONTRACTION JOINT C.L. CENTER LINE C.A. CONCRETE MONUMENT C.M.P. CONCRETE METAL PIPE C.M.U. CONCRETE MASONRY UNIT C.O. CLEAN OUT COL. COLUMN CONC. CONCRETE COND. CONDENSATE CONN. CONNECTION CONST. CONSTRUCTION CONT. CONTINUOUS COR CONTRACTING OFFICERS REPRESENTATIVE C.TO C. CENTER TO CENTER C.Y. CUBIC YARD DET. DETAIL DI DROP INLET DIA. DIAMETER DIFF. DIFFUSER DIM. DIMENSION D.I.P. DUCTILE IRON PIPE DISC. DISCONNECT D.J. DUMMY JOINT DN. DOWN DR. DRAIN D.S. DOWN SPOUT DW DOMESTIC WATER DWG.(S) DRAWING(S) EA. EACH E.F. EXHAUST FAN EG. EXISTING GRADE E.I.P. EXISTING IRON PIPE E.J. EXPANSION JOINT ELEC. ELECTRIC EL. ELEVATION E.M. ELECTRIC METER EOP EDGE OF PAVEMENT EQUIP. EQUIPMENT EVC END VERTICAL CURVE EVCE END VERTICAL CURVE ELEVATION EVCS END VERTICAL CURVE STATION EXH. EXHAUST EXP.JT. EXPANSION JOINT EXT. EXTERIOR EX./EXIST. EXISTING FC FACE OF CURB F.D. FLOOR DRAIN F.D.C. FIRE DEPARTMENT CONNECTION F.E.S. FLARED END SECTION F.F.E. FINISHED FLOOR ELEVATION FG FINISHED GRADE FH FIRE HYDRANT FIN. FINISH FLOOR FM FORCE MAIN FOC FACE OF CURB FT. FOOT, FEET FTG. FOOTING GA GAGE GAL. GALLON GALV. GALVANIZED GC GENERAL CONTRACTOR G.F.E. GOVERNMENT FURNISHED EQUIPMENT GIS GEOGRAPHIC INFORMATION SYSTEM GL GAS LINE GM GAS METER G.P.H. GALLONS/HOUR G.P.M. GALLONS/MINUTE GND. GROUND GOV'T GOVERNMENT GV GATE VALVE GW GUY WIRE HC HANDICAP HCP HANDICAP PARKING HCR HANDICAP RAMP HDW HEADWALL HP HIGH POINT HSS HIGH STRENGTH STEEL HT HEIGHT HYD HYDRANT ID. INSIDE DIAMETER INTX. INTERSECTION INV. INVERT ISL ISLAND ITL. INDEPENDENT TESTING LABORATORY J.B. JUNCTION BOX JCT. JUNCTION JSOC JOINT SPECIAL OPERATIONS COMMAND JT. JOINT K K VALVE KVA KILOVOLT AMPERE KW KILOWATT L LENGTH LF LINEAR FEET LGT LIGHT LP LIGHT POLE LT LEFT MAX MAXIMUM MED MEDIAN MH MANHOLE MIN MINIMUM MJ MECHANICAL JOINT MON MONUMENT MTL METAL MW MONITOR WELL / MICROWAVE M.U.T.C.D MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES N/A NOT APPLICABLE NAD 27 NORTH AMERICAN DATUM 1927 NAD 83 NORTH AMERICAN DATUM 1983 NBL NORTH BOUND LINE NC NORMAL CROWN NEMA NATIONAL ELECTRICAL MANUFACTURES ASSOCIATION NIC NOT IN CONTRACT NIP NEW IRON PIPE N.T.S. NOT TO SCALE O.U. ON CENTER O.V. OUTSIDE DIAMETER OH OVERHEAD OHE OVERHEAD ELECTRIC ONUS. OLD NORTH UTILITY SERVICE OVH OVERHANG P/A PARKING AREA PC POINT OF CURVATURE PCC POINT OF COMPOUND CURVATURE PED PEDESTAL PER. PERIMETER PGL PROPOSED GRADE LINE PI POINT OF INTERSECTION PINC POINT OF INTERSECTION ON CURVE PIV POST INDICATOR VALVE PIV ELEV POINT OF VERTICAL INTERSECTION ELEVATION PLT PLATE PSF POUNDS PER SQUARE FOOT PSF POUNDS/SQUARE FOOT PSI POUNDS/SQUARE INCH PIV STA POINT OF VERTICAL INTERSECTION STATION PT POINT PVMT PAVEMENT RAD. RADIUS RCP REINFORCED CONCRETE PIPE REINF. REINFORCING REQ. REQUIRED REV REVISED R.P.Z. REDUCED PRESSURE ZONE RT RIGHT R/W RIGHT OF WAY RWM RIGHT OF WAY MONUMENT SAN SANITARY SEWER SB SOIL BORING SCH SCHEDULE SET SETBACK SF SQUARE FEET SHT SHEET SIA SIAMESE CONNECTION SIG SIGNAL SOTF SECURITY OPERATIONS TRAINING FACILITY SP SIGNAL POLE SPECS SPECIFICATIONS SQFT SQUARE FEET SR STATE ROAD SS SANITARY SEWER STA. STATION STD. STANDARD STM STORM STL STEEL SW SIDEWALK SWM. STORMWATER MANAGEMENT T TANGENT TBM TEMPORARY BENCHMARK TERR TERRA COTTA PIPE TEL TELEPHONE TOC TOP OF CURB TOB TOP OF BANK TOS TOP OF SLOPE TOW TOP OF WALL TP TELEPHONE POLE TRANS TRANSFORMER TYP. TYPICAL U/C UNDER CONSTRUCTION U/G UNDERGROUND UNO UNLESS NOTED OTHERWISE UP UTILITY POLE VC VERTICAL CURVE VCP VITRIFIED CLAY PIPE VIF VERIFY IN FIELD WL WATER LINE WM WATER METER WSEL WATER SURFACE ELEVATION WV WATER VALVE WTR WATER WWF WIRE WELD FABRIC AL4RPV AL4RPV FSJ4-50 FSJ4-50 HL4RPV HL4RPV FSJ1-50 FSJ1-50 LMR-240 LMR-240 PTS1-50 PTS1-50 LDF1-50 LDF1-50 OHF OHF OHF UGF UGF UGF UGF TFT-402 TFT-402 SMF SMF SMF MMF MMF MMF SM288 SM288 SM144 SM144 SM96 SM96 SM96 SM48 SM48 SM48 SM24 SM24 SM24 SM12 SM12 SM12 SM6 SM6 SM6 LDF4-50 LDF4-50 CAT6 CAT6 CAT6 COAX COAX COAX C C C ETH ETH ETH GAS GAS GAS GND GND GND CAT5 CAT5 CAT5 DCP DCP DCP ACP ACP ACP OHP OHP OHP UGW UGW UGW R/W R/W R/W SF SF SF PARENT PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY EASEMENT LEASE AREA RIGHT OF WAY SILT FENCE X X X XCHAIN-LINK FENCE UNDERGROUND WATER UGP UGP UGP UGPUNDERGROUND POWER OVERHEAD POWER ALTERNATING CURRENT POWER DIRECT CURRENT POWER FO/DC FO/DC FO/DC HYBRID HYBRID FIBER/DC POWER COMPOSITE CABLE HYBRID CABLE UNDERGROUND FIBER OVERHEAD FIBER MULTI-MODE FIBER SINGLE-MODE FIBER FIBER TRUNK - 6 STRAND FIBER TRUNK - 12 STRAND FIBER TRUNK - 24 STRAND FIBER TRUNK - 48 STRAND FIBER TRUNK - 96 STRAND FIBER TRUNK - 144 STRAND FIBER TRUNK - 288 STRAND GROUND WIRE GAS LINE ETHERNET CABLE ALM ALM ALM CAT6 CABLE CAT5 CABLE ALARM CABLE CONDUIT COAX FEEDLINE COAX FEEDLINE / JUMPER - TFT-402 COAX FEEDLINE / JUMPER - PTS1-50 COAX FEEDLINE / JUMPER - LMR-240 COAX FEEDLINE / JUMPER - LDF4-50 COAX FEEDLINE / JUMPER - LDF1-50 COAX FEEDLINE / JUMPER - HL4RPV COAX FEEDLINE / JUMPER - FSJ4-50 COAX FEEDLINE / JUMPER - FSJ1-50 COAX FEEDLINE / JUMPER - AL4RPV R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W X 1. SITE PLAN BASED ON SURVEY COMPLETED BY JMT DATED 03/11/2025. 2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD. ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT ASSUME RESPONSIBILITY FOR THIS CONTENT. NOTES PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION OVERALL PROPERTY PLAN C-1.0 PROPOSED 120'± MONOPOLE SETBACKS PROPERTY BOUNDARY LINEDISTANCE NORTH291'-1"± EAST195'-6"± SOUTH515'-5"± WEST216'-3"± N NW W SW S SE E NE NNW WNW WSW SSW SSE ESE ENE NNE 1" = 200'-0" OVERALL PROPERTY PLAN PARENT PROPERTY OWNER: CAROLINA POWER & LIGHT PARCEL: 2060002010 ACRES: 3.3 EXISTING ACCESS ROAD SITE PLAN DATA TABLE OWNER OF RECORDCAROLINA POWER & LIGHT CO DUKE ENERGY CENTER 550 S TRYON STREET CHARLOTTE, NC 28202 APPLICANTDUKE ENERGY PROGRESS INC 150 FAYETTEVILLE STREET, BOX 1011 HICKORY, NC 28601 PRIMARY CONTACT SSEE T-1 PROJECT ADDRESS2434 WEDGEFIELD RD. SUMTER, SC 29154 TAX MAP IDENTIFICATION NUMBER206-00-02-010 WITHIN SUMTER CITY LIMITSYES PROPOSED USE120' UTILITY POLE FOR DUKE ENERGY INTERNAL USE FOR SUBSTATION REMOTE ACCESS ZONING DISTRICTR-15 MINIMUM DEVELOPMENT REQUIREMENTS MINIMUM LOT AREA PER INDIVIDUAL UNIT N/A MINIMUM LOT WIDTH100 FT. MINIMUM LOT DEPTH120 FT. MINIMUM YARDS, PER STRUCTURE FRONT35 FT. SIDE50 FT. REAR50 FT. MAXIMUM IMPERVIOUS SURFACE PERCENTAGE0.4 MAXIMUM DENSITY (UNITS PER GROSS ACRE)N/A MAXIMUM HEIGHT OF BUILDINGS45 FT. FEMA FLOODPLAIN INSURANCE MAP INFORMATIONMAP NUMBER 45085C0292E EFFECTIVE ON 10/27/2022 SIZE OF PARCEL10.0 ACRES SIZE OF SITE PLAN0.8043 PERCENTAGE OF PARCEL UNDEVELOPED0.08 EXISTING BUILDINGSN/A WEDGEFIELD ROAD FREEDOM BOULEVARD GRIFFIN LN W OAKLAND AVENUE STILLPOINTE DRIVE CONIFER STREET CONIFER STREET ACON STREET ADJACENT PROPERTY OWNER: HUTCHISON RYAN MILLER PARCEL: 2060701010 ACRES: 0.70 ADJACENT PROPERTY OWNER: COLLINS DONNIE & MIRIAM PARCEL: 2060701011 ACRES: 0.59 ADJACENT PROPERTY OWNER: CLARK LETHALIE KATHY PARCEL: 2060701012 ACRES: 0.59 ADJACENT PROPERTY OWNER: BRUNSON STEVE S & THELMA T PARCEL: 2060701013 ACRES: 0.59 ADJACENT PROPERTY OWNER: NASH DAVID R PARCEL: 2060701014 ACRES: 0.59 ADJACENT PROPERTY OWNER: GAINEY CONSTRUCTION CO LLC PARCEL: 2060701074 ACRES: 0.60 ADJACENT PROPERTY OWNER: PALMETTO PROPERTIES OF SUMTER PARCEL: 2060701016 ACRES: 0.23 ADJACENT PROPERTY OWNER: JSAL ENTERPRISES LLC PARCEL: 2060701017 ACRES: 0.22 ADJACENT PROPERTY OWNER: JSAL ENTERPRISES LLC PARCEL: 2060701018 ACRES: 0.24 ADJACENT PROPERTY OWNER: PALMETTO PROPERTIES OF SUMTER PARCEL: 2060202006 ACRES: 0.41 ADJACENT PROPERTY OWNER: MAY SALLY ROBINSON ESTATE PARCEL: 2060202004 ACRES: 0.63 ADJACENT PROPERTY OWNER: ALI JORDAN BASSET & JUSTIN ROB PARCEL: 2060701019 ACRES: 0.39 ADJACENT PROPERTY OWNER: BURKIN DAVID S & RANDI L PARCEL: 2060701021 ACRES: 0.21 ADJACENT PROPERTY OWNER: HERBERT PAUL G & MARY A PARCEL: 2060701022 ACRES: 0.53 ADJACENT PROPERTY OWNER: DAVIS-FREEMAN JUANA L PARCEL: 2060701023 ACRES: 0.57 ADJACENT PROPERTY OWNER: ASANTE DELANO YAW PARCEL: 2060701024 ACRES: 0.60 ADJACENT PROPERTY OWNER: DOBATO DE COOK CONCEPCION PARCEL: 2060701025 ACRES: 0.68 ADJACENT PROPERTY OWNER: YOMTOB JESSE A PARCEL: 2060701026 ACRES: 0.62 ADJACENT PROPERTY OWNER: ROGERS KENNETH & MARLENE PARCEL: 2060701027 ACRES: 0.50 PROPOSED 120'± MONOPOLE FALLZONE GNDGNDGNDGND GND GND GNDGNDGND GND GND GND GND UGF X X X X X X X X X X X X X X XXXXXXXXX XXXXXXXXX X X XX X X X X X X X GND GND GND GNDGND GND GNDGND PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION SUBSTATION COMPOUND PLAN C-1.1 N NW W SW S SE E NE NNW WNW WSW SSWSSE ESE ENE NNE 1" = 20'-0" SUBSTATION COMPOUND PLAN EXISTING SUBSTATION EQUIPMENT (TYP.) PROPOSED DUKE ENERGY 120'± MONOPOLE W/ CAMBIUM EQUIPMENT (SEE SHEET C-2) PROPOSED COMMUNICATION POLE BASE GROUNDING BONDED TO EXISTING SUBSTATION GROUND MAT (SEE SHEETS C-1.2 & C-3.2) PROPOSED BURIED 2" CONDUITS (1) W/ CAT5E CABLE (CAMBIUM P/N: WB3176A) (~45') (1) EMPTY FOR FUTURE USE (SEE SHEET C-1.3) EXISTING TELECOM EQUIPMENT CABINET 35'-0" 10'-0" 36'-8" 4'-0" 4'-0" PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION TRANSMISSION GROUNDING PLAN C-1.2 N.T.S. TRANSMISSION GROUNDING PLAN FOR REFERENCE ONLYFOR REFERENCE ONLY PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION TRANSMISSION CONDUIT PLAN C-1.3 N.T.S. TRANSMISSION CONDUIT PLAN #DESCRIPTION & FUNCTIONSIZELENGTHSIZELENGTHREMARKS 82120' CAMBIUM POLE TO TELECOM EQUIPMENT CAB2" PVC50'CAT5E170'CABLE LENGTH INCLUDES TOWER HEIGHT 83120' CAMBIUM POLE TO TELECOM EQUIPMENT CAB2" PVC50'----SPARE FOR REFERENCE ONLYFOR REFERENCE ONLY PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION COMMUNICATION POLE ELEVATION & ANTENNA PLAN C-2 1/16" = 1'-0" COMMUNICATION POLE ELEVATION 1" = 32'-0" ANTENNA PLAN 0'-0" FINISHED GRADE N NW W SW S SE E NE NNW WNW WSW SSW SSE ESE ENE NNE 1. CONTRACTOR TO REFER TO MOST RECENT TOWER ANALYSIS, COMPLETED BY ENGINEERED TOWER SOLUTIONS, PRIOR TO INSTALLATION. 2. COMMUNICATION POLE TO BE A GALVANIZED STEEL COLOR TO BLEND IN WITH EXISTING TRANSMISSION LINE EQUIPMENT. 3. COMMUNICATION POLE INTENDED FOR DUKE ENERGY EQUIPMENT ONLY. NO TENANTS ARE PERMITTED TO CO-LOCATE ONTO COMMUNICATION POLE. NOTES 120'-0" TOP OF COMMUNICATION POLE SIZE (FT)TYPE MANUFACTURER PART #ELEVATION (FT)AZIMUTHMOUNT 4'ANTENNARADIOWAVESHPD4-5.2118'-0"103.54° SITE PRO 1 DCH8 CHAIN MOUNT 5.3"x10.3"x3.3"ODUCAMBIUM NETWORKSPMP450i NON-INTEGRATED |118'-0"-- 96.0"x14.6"x8.7"LTE ANTENNA (FUTURE)JMA(9) X7CQAP-86-880-VR060'-- PV-LPPGS-12M-HR2- AP19-AT (12.5 FT PLATFORM MOUNT) 27.20"x12.05"x7.0 "RRUS (FUTURE)ERICSSON(9) RRUS 3260'-- 31.41"x18.28"x9.6 6" SURGE SUPPRESSOR (FUTURE) RAYCAP(3) DC6-48-60-18-8C60'-- 118'-0" ANTENNA C.L. 124'-0" TOP OF LIGHTNING ROD 60'-0" FUTURE ANTENNA C.L. AZIMUTH 103.54 ° PROPOSED DUKE ENERGY 120'± MONOPOLE PROPOSED DUKE ENERGY MW DISH ANTENNA PROPOSED DUKE ENERGY CHAIN MOUNT PROPOSED DUKE ENERGY CAMBIUM ODU PROPOSED DUKE ENERGY STABILIZER BAR PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION DETAILS I C-3.1 CHAIN MOUNT DETAIL N.T.S. VALMONT - TCHM1 ·TAPER ADJUSTABLE CHAIN MOUNT ·FITS POLYGON OR ROUND POLES ·ALLOWS FOR UP TO 6° OF TAPER IN 3/4° INCREMENTS ·INCLUDES U-BOLTS FOR MOUNTING 2-3/8" OR 4-1/2" OD PIPES ·MOUNTING PIPE ORDERED SEPARATELY N.T.S. U-BOLTS INCLUDED FOR 2-3/8" OR 4-1/2" OD MOUNTING PIPES 5'-0"x4-1/2" OD SCH.40 ANTENNA MOUNTING PIPE (ORDERED SEPARATELY ) 5'-0" 4-1/2" OD ODU DETAIL N.T.S. CAMBIUM NETWORKS - PMP 450i N.T.S. HEIGHTWIDTH DEPTHWEIGHT ANTENNA CONNECTORFREQUENCY 10.3" 5.3" 3.3" 4.5 LBS(2) N-TYPE FEMALE3 GHz: 3300 - 3900 MHz 5 GHz: 4900 - 5925 MHz WIDTH DEPTH HEIGHT 2'-0"x2-3/8" OD SCH.40 ODU MOUNTING PIPE (ORDERED SEPARATELY) ODU MOUNTING DETAIL N.T.S. 5'-0"x4-1/2" OD SCH.40 ANTENNA MOUNTING PIPE ODU MOUNTED TO 2'-0"x2-3/8" OD SCH.40 MOUNTING PIPE PER MANUFACTURER SPECIFICATIONS MOUNTED ON BACKSIDE OF PIPE ADAPTER CLAMP SET ANTENNA (BEYOND) ADAPTER CLAMP SET (ANDREW AD-P60-SCP) ADAPTER CLAMP SET: ANDREW - AD-P60-SCP ·FITS PIPES 4-1/2" TO 12" ·INCLUDES (4) 1/2"x4" THREADED RODS / HARDWARE ·INCLUDES (4) 5/8"x8" THREADED RODS / HARDWARE ·ODU MOUNTING PIPE ORDERED SEPARATELY LPU MOUNTED TO 2'-0"x2-3/8" OD SCH.40 MOUNTING PIPE PER MANUFACTURER SPECIFICATIONS ANTENNA DETAIL N.T.S. RADIOWAVES - HPD4-5.2 N.T.S. DIAMETERWEIGHT ANTENNA CONNECTORFREQUENCY 4'-0"85 LBS N-TYPE FEMALE5.25 - 5.85 GHz radiowaves DIAMETER PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION DETAILS II C-3.2 COMMUNICATION POLE BASE DETAIL (SIDE VIEW) N.T.S. N.T.S. CAT5E CABLE UP TO EQUIPMENT 2" WEATHERHEAD (TYP.) MAIN GROUND BAR MOUNTED TO COMMUNICATION POLE BASE GND GND GND GND GND GND GND GND GND GND GNDGNDGNDGNDGND GND EXISTING GROUND GRID 2/0 AWG, CU, SOFT DRAWN, 19 STR, INSULATED THWN CONDUCTOR (TYP.) COMMUNICATION POLE BASE DETAIL (FRONT VIEW) N.T.S. N.T.S. MAIN GROUND BAR MOUNTED TO COMMUNICATION POLE BASE 2/0 AWG, CU, SOFT DRAWN, 19 STR, INSULATED THWN CONDUCTOR (TYP.) EXISTING GROUND GRID (2) 2" PVC CONDUITS TO BASE EQUIPMENT (1) W/ CAT5E CABLE (1) EMPTY FOR FUTURE USE (SEE SHEET C-1.1 FOR ROUTE) CAT5, 4 PAIR 24 AWG, CU SHIELDED INSULATION ROUTED ON EXTERIOR OF POLE 2" WEATHERHEAD (TYP.) GNDGNDGNDGNDGNDGNDGNDGNDGND 2'-0" MIN. 5'-0" GNDGNDGNDGNDGNDGNDGNDGND GND GND GND GNDGND GND GND 2" SCH. 40 GRAY PVC CAP GNDGNDGNDGNDGNDGNDGNDGND GND CAT5, 4 PAIR 24 AWG, CU SHIELDED INSULATION ROUTED ON EXTERIOR OF POLE (SEE CABLE ROUTING DETAIL) UPPER TOWER GROUND BAR, 2" WD X 12" LG X 1/4" THK, W/ INSULATORS & BRACKETS, (18) PRE-DRILLED 7/16" HOLES MECHANICAL BOND GROUND WITH COMPRESSION LUGS (TYP.) 2/0 AWG, CU, SOFT DRAWN, 19 STR, INSULATED THWN CONDUCTOR (TYP.) 2/0 AWG, CU, SOFT DRAWN, 19 STR, BARE COPPER, CLASS B CONNECTOR,ELECTRICAL, TERMINAL, LUG, 2 AWG CONDUCTOR, (2) 3/8" HOLE TERMINATION, BLACK, STD COMPRESSION CONNECTOR, ELECTRICAL, TERMINAL, LUG, 2 AWG CONDUCTOR, (2) 3/8" HOLE TERMINATION CABLE HOISTING GRIP, 3/8" CABLE, SS, PRE-LACED STANDOFF BRACKET WITH STACKABLE SNAP-IN HANGER (TYP.) ENLARGED COMMUNICATION POLE TOP DETAIL N.T.S. GNDGND GND GND GNDGNDGNDGNDGND GND GND GND GNDGNDGNDGND GND GND GND GND GND GNDGNDGND GND GND GND GND GND GNDGNDGND GND GNDGNDGND PARABOLIC ANTENNA MOUNTED TO 5'-0"x4-1/2" OD SCH.40 PIPE PER MANUFACTURER SPECIFICATIONS CHAIN MOUNT 4'-0"x1/2"Ø COPPER CLAD AIR TERMINAL INTERNALLY THREADED CAT5, 4 PAIR 24 AWG, CU SHIELDED INSULATION ROUTED ON EXTERIOR OF POLE (SEE CABLE ROUTING DETAIL) ODU MOUNTED TO 2'-0"x2-3/8" OD SCH.40 PIPE PER MANUFACTURER SPECIFICATIONS CABLE GROUNDING KIT LPU MOUNTED TO 2'-0"x2-3/8" OD SCH.40 PIPE PER MANUFACTURER SPECIFICATIONS UPPER TOWER GROUND BAR MECHANICAL BOND GROUND WITH COMPRESSION LUGS (TYP.) 2/0 AWG, CU, SOFT DRAWN, 19 STR, INSULATED THWN CONDUCTOR (TYP.) SEE ENLARGED COMMUNICATIONS POLE TOP DETAIL COMMUNICATION POLE TOP DETAIL N.T.S. GND GND GNDGND GND GNDGND GND GND GNDGND GND GND GND GND GND GND GND GND PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION DETAILS III C-3.3 WIRE/CABLE, 2/0 AWG, CU, SOFT DRAWN, 19 STR, BARE COPPER, CLASS B TIED TO GROUND BAR (SEE NOTES) NOTES: ·DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR ·GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO-HOLE LUG ·WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT; COLD SHRINK SHALL NOT BE USED FEEDLINE CABLE GROUNDING DETAIL N.T.S. 1'-0" TO 2'-0" 2 1/2" Ø MAX. WEATHERPROOFING KIT (SEE NOTES) FEEDLINE CABLE CABLE GROUND KIT N.T.S. 3/4" STAINLESS STEEL BANDING (ATTACHED TO EXTERIOR OF MONOPOLE) CABLE ROUTING DETAIL CAT5E CABLE SNAP-IN HANGER W/ SINGLE-HOLE BARREL CUSHION (VALMONT P/N: CIN3812) 3'-0" 3'-0" SNAP-IN ASSEMBLY (SEE DIAGRAM) STANDOFF BRACKET (VALMONT P/N: MST-U) CAT5E CABLE COMMUNICATION POLE SNAP-IN ASSEMBLY CADWELD GROUNDING DETAIL N.T.S. GROUND WIRE (TYP.) GROUND ROD CADWELD (TYP.) NOTES: ·MINIMUM SPACING OF 1'-0" BETWEEN ALL CADWELDS. ·TOP VIEW DETAIL ONLY TO BE USED AT SPLICE LOCATIONS. TOP VIEW SIDE VIEW GROUND WIRE (TYP.) GROUND ROD CADWELD (TYP.) TRENCH DETAILS N.T.S. PROPOSED WARNING TAPE (6"-8" BFG) 4"2" PROPOSED 2" CONDUIT RESTORE SURFACE COURSE AND BASE MATERIAL TO ORIGINAL CONDITION GRAVEL BASE COMPACTER TO 95% STANDARD PROCTOR MAXIMUM DRY DENSITY NATIVE SOIL 4" (TYP.) FINISHED GRADE (GRAVEL) 4" (TYP.) 4" (TYP.) PROPOSED 2" SPARE CONDUIT POLE SLIP JOINT DETAIL N.T.S. NOTE: IF POLE SECTIONS ARE JACKED TOGETHER PRIOR TO LIFTING AND SETTING THE POLE IN THE HOLE, THE POLE SECTIONS SHALL BE BOLTED AT THE SLIP JOINTS 1'-0"6" 7/8"x48" BOLT W/ 7/8" WASHER, BOLT & LOCK WASHER (TYP.) PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION DETAILS V C-3.4 1 2 3 25 2'-0" MIN. 10 19 20 15 12 16 10 24 27 2 5'-0" 11 9 13 14 19 19 10 17 18 22 10 T1 T1 T2 20 11 T3 T6 T4 2 GNDGNDGNDGNDGNDGNDGNDGND GND GNDGNDGNDGNDGNDGNDGNDGNDGND GNDGNDGNDGNDGNDGNDGNDGND GND GND GND GNDGND GND GND 5 3 5 GND 5 2 3 T5T5 8 26 6 6 GND GNDGND GND GND GND 3 GNDGND GND GND GNDGND GND GND GND GND GND GND GND GND 3 3 29 28 TRANSMISSIONS ITEMQTYUIMAXIMO P/NDESCRIPTIONNOTES T1 TBD EA 61354CONDUIT, RIGID, HEAVY WALL, 2", 10' LG, SCH 40, PVC, LG BELLED ONE END, RATED F/ 90 DEG C2" x 10'-0" SCH. 40 GRAY PVC W/ COUPLING ON ONE END T2 2 EA 79433ELBOW,CONDUIT, RIGID, 2", GRAY PVC, 90 DEG, 9-1/2" RADIUS, PLAIN END, F/ 2" CONDUIT; PACKAGING: 15 PER PACK2" x 9-1/2" RADIUS SCH. 40, 90 DEGREE PVC ELBOW T316 FT 4177461WIRE/CABLE, ELECTRICAL, BARE, GROUND, 19 STR SOL SD, 9 AWG, DEAD SOFT ANNEALED COPPERCLAD 2 CONNECTIONS / POLE ASSUME MINIMUM 2' ABOVE 4' BELOW T4 1 BX50130218POWDER, WELDING, EXO., #300PLUS20, LIGHT GREENCAD WELD 4 PER POLE 10 CARTRIGES /BOX T52 EA67295TERMINAL, TIN PLTD CU CONDUCTOR, WELDED CONDUCTOR CONNECTION, (2) 1/2" HOLE 1-3/4" CTRPOLE HOLE PATTERN TO CAD WELD 9X19 TO GRID MAT T61N/AEXISTING SUBSTATION GROUND MAT2 CONNECTIONS TO GRID MAT ASSUME 4' DEPTH ITEMQTYUIMAXIMO P/NDESCRIPTIONNOTES/ENGINEERING RULE 1 1 EA 1505632AIR TERMINAL, COPPER CLAD AIR BASE, 1/2" DIA. X 48"MOUNT THE LIGHTNING ROD 180° AWAY FROM DISH POSITION 2 1 RO 4177461WIRE/CABLE, 2/0 AWG, CU, SOFT DRAWN, 19 STR, BARE CU, CLASS B, PACKAGED IN 25' HAND COILSAPPROXIMATELY 16' REQUIRED 3 6 EA 1503888TERMINAL, LUG, 2/0 AWG CONDUCTOR, (2) 1/2" HOLE BLACK, 1-3/4" CTRFITS EVERY BONDING CONNECTOR WELDED TO VALMONT H-10 POLE 4 1 EA 1612775TERMINAL, LUG, 2/0 AWG CONDUCTOR, (2) 1/2" HOLE, 1" CTR , BLACK, LONGNEED 2 PER POLE - 2 ON LOWER GROUND BAR, (MAIN GNDS AT BOT) 1 ON UPPER 53 EA 1504572TERMINAL, LUG, 2/0 AWG, COMP , CU , (2) 3/8" HOLE, 1" CTRNEED 1 PER POLE - 1 ON UPPER GND BAR ( MAIN GND AT TOP) 2 ON LOWER 6 2 EA 1505554TERMINAL, LUG, 2/0 AWG CONDUCTOR, SGL HOLE 3/8" POST F/2/0 AWG SINGLE HOLE 2 PER POLE, BOND FOR THE 4.5”& 2.5” PIPE 73EA LOOSETERMINAL, LUG, # 6 AWG , (2) 1/2" HOLE, 1 3/4" SPACE BLUE, LONGUSED FOR MID CAT-5 BOND TO POLE GROUND NEW PART 81EA 1525371BAR, GROUND, 2" WD X 12" LG X 1/4" THK, W/ INSULATORS & BRACKETS, (18) PRE-DRILLED 7/16" HOLEBAR, GROUND - ENGINEERING RULE = TOP GROUND BAR - VERT 91 EA1505048BAR, GROUND, BUSS, 4" WD X 14" LG X 1/4" THK, TINNED, W/ HARDWAREBAR, GROUND - ENGINEERING RULE = BOTTOM GROUND BAR - HORIZ 3/4", 1" AND 1-3/4" ON CENTER 101 KT1539777LPU KIT, GROUNDING, LIGHTNING PROTECTION UNIT, ETHERNET CABLE, PRE-FITTED CABLE GLAND,ENGINEERING RULE = 1 LPU KIT PER OSP CAT-5 CABLE (2 PER KIT) 11 1SP 1539773WIRE/CABLE,ELECTRICAL, CAT5, 4 PAIR, 24 AWG, CU, SHIELDED INSULATIONENGINEERING RULE = SPOOL 328' - POLE 120' RADIO TO LPU MAXIMUM DISTANCE TO ISP PSU = 320' 12 4 PK1473338BRACKET, STANDOFF, MOUNTING, UNIVERSAL, NO ADAPTERBRACKET - 10/BAG ENGINEERING RULE = 1 EVERY 3 FEET 13 4 PK 1505037HANGER, CABLE, SNAP-IN STACKABLE, F/ 1-5/8" CABLESNAP-IN, 10/BAG - ENGINEERING RULE = 1 EVERY 3 FEET 14 4 PK 1564840CUSHION, BARREL, 1-5/8", UNIVERSAL, 14-36MM, SNAP-IN, 10 PER BOXBARREL CUSHION, 10/BAG - ENGINEERING RULE = 1 EVERY 3 FEET 151 EA1554484GRIP,CABLE, HOISTING, 3/8" CABLE, SS, PRE-LACEDENGINEERING RULE = 1 PER CAT-5 RISER TOP & MID IF > 200' 161 EA1503531PIPE, 5' LG, ALUM, 4-1/2" OD, F/ ANTENNA MOUNTPIPE, 5' LG, ALUM, 4-1/2" OD, 1 per DISH 17 1 EA 1479381PIPE, 2-3/8", 2' LG, PLAIN ENDS, STL, F/ ANTENNA MOUNTPIPE, 2-3/8", 2' LG, 1 per Radio/LPU ASSY 181EA 1501289BRACKET, MOUNTING, HOT DIP GALV STL, BOOM GATE CLAMP SET, 4-1/2" TO 12", 60 DEG ANGLE LEGS TOWER LEG CLAMP SET ENGINEERING RULE = 1 PER 2' RADIO/LPU ASSY 19 3EA1539778KIT, SHIELD GROUNDING, GROUND STRIPS, MASTIC TAPE, ELECTRICAL TAPE, GROUND BOLT & NUT, RETAINING ZIP TIES, F/ (1) AT BOTTOM (1) AT MIDDLE (ABOVE SLIP JOINT) (1) AT TOP OF MONOPOLE" 20 4 RO 1490605BAND,STRAPPING, 3/4" WD, 100' LG, 0.03" THK, 316 SS, 1800 LBBAND,STRAPPING, 3/4" ASSUME 6' DIAMETER & ALL OTHER MISC 2150 EA 1490606BUCKLE, BANDING, 3/4" WIDE, SSBUCKLE, BANDING, 3/4" WD, SS 22 2 EA904105HEAD,SERVICE ENTRANCE,RIGID,2",SLIP-ON,PVC,WEATHER HD,STD PKG/5WEATHER HEAD, 2" ALL TO BE SCHEDULE 40 231 EA1545989BRACKET, MOUNTING, CAMBIUM TILT BRACKET ASSYBRACKET, MOUNTING, CAMBIUM TILT BRACKET ASSY Engineering Rule = 1 per PMP-450 REMOVE for 670 24 1 EA1546830MODULE, RADIO FREQUENCY, CAMBIUM 5X GHZ 450i INTEGRATED SUBSCRIBER MODULE5 GHz PMP 450i Int SM 251 EA1588737CHAIN MOUNT, FLUSH ANTENNA, CHAIN MOUNT, TIE BACK ARMS, U-BOLTS, F/ DISH ANTENNA W/ SIDE SUPPORT BRACKETS, F/ 4-1/2" DIA - 4' AND 6' DISH ONLY - DHC8 SA-B10 INCLUDES U-BOLTS FOR MOUNTING 4-1/2'' OD PIPES AND SIDE-STRUT SUPPORT BRACKET FOR TIE-BACK ARMS 262 EA1570020JUMPER, COAX, 3' LG, N MALE TO N MALE, LMR-400JUMPER, COAX, 3' LG, N MALE TO N MALE, LMR-400 27 1 EA1564958ANTENNA, PARABOLIC DISH, 5.25-5.85GHZ, N-FEMALE CONNECTOR, 4' HPDP, 34.9 DBI GAIN4' HPDP CAMBIUM NON-INTEGRATED PMP OR PTP APPLICATIONS 28 2 EA 1501100BRACKET, MOUNTING, STABILIZER BARS-STIFF ARM-- 292EA 1624192BRACKET, MOUNTING, 8" WD X 8" LG X 6" HT, HOT DIP GALV STL-- R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W X 1. SITE PLAN BASED ON SURVEY COMPLETED BY JMT DATED 03/11/2025. 2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD. ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT ASSUME RESPONSIBILITY FOR THIS CONTENT. NOTES PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SUBSTATION ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SUBSTATION NAME: SUBSTATION TRANSMISSION NUMBER: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: 0 CHECKED BY: PB DRAWN BY: DF 07/24/2025 T3985 COA: REV DATEDETAILS 0 1 2 3 07/24/2025 CONSTRUCTION OVERALL PROPERTY PLAN C-1.0 PROPOSED 120'± MONOPOLE SETBACKS PROPERTY BOUNDARY LINEDISTANCE NORTH291'-1"± EAST195'-6"± SOUTH515'-5"± WEST216'-3"± N NW W SW S SE E NE NNW WNW WSW SSW SSE ESE ENE NNE 1" = 200'-0" OVERALL PROPERTY PLAN PARENT PROPERTY OWNER: CAROLINA POWER & LIGHT PARCEL: 2060002010 ACRES: 3.3 EXISTING ACCESS ROAD SITE PLAN DATA TABLE OWNER OF RECORDCAROLINA POWER & LIGHT CO DUKE ENERGY CENTER 550 S TRYON STREET CHARLOTTE, NC 28202 APPLICANTDUKE ENERGY PROGRESS INC 150 FAYETTEVILLE STREET, BOX 1011 HICKORY, NC 28601 PRIMARY CONTACT SSEE T-1 PROJECT ADDRESS2434 WEDGEFIELD RD. SUMTER, SC 29154 TAX MAP IDENTIFICATION NUMBER206-00-02-010 WITHIN SUMTER CITY LIMITSYES PROPOSED USE120' UTILITY POLE FOR DUKE ENERGY INTERNAL USE FOR SUBSTATION REMOTE ACCESS ZONING DISTRICTR-15 MINIMUM DEVELOPMENT REQUIREMENTS MINIMUM LOT AREA PER INDIVIDUAL UNIT N/A MINIMUM LOT WIDTH100 FT. MINIMUM LOT DEPTH120 FT. MINIMUM YARDS, PER STRUCTURE FRONT35 FT. SIDE50 FT. REAR50 FT. MAXIMUM IMPERVIOUS SURFACE PERCENTAGE0.4 MAXIMUM DENSITY (UNITS PER GROSS ACRE)N/A MAXIMUM HEIGHT OF BUILDINGS45 FT. FEMA FLOODPLAIN INSURANCE MAP INFORMATIONMAP NUMBER 45085C0292E EFFECTIVE ON 10/27/2022 SIZE OF PARCEL10.0 ACRES SIZE OF SITE PLAN0.8043 PERCENTAGE OF PARCEL UNDEVELOPED0.08 EXISTING BUILDINGSN/A WEDGEFIELD ROAD FREEDOM BOULEVARD GRIFFIN LN W OAKLAND AVENUE STILLPOINTE DRIVE CONIFER STREET CONIFER STREET ACON STREET ADJACENT PROPERTY OWNER: HUTCHISON RYAN MILLER PARCEL: 2060701010 ACRES: 0.70 ADJACENT PROPERTY OWNER: COLLINS DONNIE & MIRIAM PARCEL: 2060701011 ACRES: 0.59 ADJACENT PROPERTY OWNER: CLARK LETHALIE KATHY PARCEL: 2060701012 ACRES: 0.59 ADJACENT PROPERTY OWNER: BRUNSON STEVE S & THELMA T PARCEL: 2060701013 ACRES: 0.59 ADJACENT PROPERTY OWNER: NASH DAVID R PARCEL: 2060701014 ACRES: 0.59 ADJACENT PROPERTY OWNER: GAINEY CONSTRUCTION CO LLC PARCEL: 2060701074 ACRES: 0.60 ADJACENT PROPERTY OWNER: PALMETTO PROPERTIES OF SUMTER PARCEL: 2060701016 ACRES: 0.23 ADJACENT PROPERTY OWNER: JSAL ENTERPRISES LLC PARCEL: 2060701017 ACRES: 0.22 ADJACENT PROPERTY OWNER: JSAL ENTERPRISES LLC PARCEL: 2060701018 ACRES: 0.24 ADJACENT PROPERTY OWNER: PALMETTO PROPERTIES OF SUMTER PARCEL: 2060202006 ACRES: 0.41 ADJACENT PROPERTY OWNER: MAY SALLY ROBINSON ESTATE PARCEL: 2060202004 ACRES: 0.63 ADJACENT PROPERTY OWNER: ALI JORDAN BASSET & JUSTIN ROB PARCEL: 2060701019 ACRES: 0.39 ADJACENT PROPERTY OWNER: BURKIN DAVID S & RANDI L PARCEL: 2060701021 ACRES: 0.21 ADJACENT PROPERTY OWNER: HERBERT PAUL G & MARY A PARCEL: 2060701022 ACRES: 0.53 ADJACENT PROPERTY OWNER: DAVIS-FREEMAN JUANA L PARCEL: 2060701023 ACRES: 0.57 ADJACENT PROPERTY OWNER: ASANTE DELANO YAW PARCEL: 2060701024 ACRES: 0.60 ADJACENT PROPERTY OWNER: DOBATO DE COOK CONCEPCION PARCEL: 2060701025 ACRES: 0.68 ADJACENT PROPERTY OWNER: YOMTOB JESSE A PARCEL: 2060701026 ACRES: 0.62 ADJACENT PROPERTY OWNER: ROGERS KENNETH & MARLENE PARCEL: 2060701027 ACRES: 0.50 PROPOSED 120'± MONOPOLE FALLZONE View Map CAROLINA POWER & LIGHT ATTN. DUKE ENERGY CORPORATION PO BOX 37996 CHARLOTTE NC 28237 Year 2024 2023 2022 2021 Market Land Value $130,000 $130,000 $130,000 $130,000 + Market Improvement Value $0 $700 $700 $700 + Market Misc Value $700 $0 $0 $0 = T otal Market/Exemption Value $130,700 $130,700 $130,700 $130,700 Assessed Land Value $0 $13,660 $13,660 $13,660 + Assessed Improvement Value $0 $70 $70 $70 + Assessed Misc Value $0 $0 $0 $0 = T otal Assessed Value $20 $13,730 $13,730 $13,730 Legal Residence Form Mailing Address Change Military Non-Resident Land Use Units Unit Type Land Type Notes AgUse Value Market Land Value UTIL (21) 5 Land Rate Code 9006 OPEN/CULTIVATED B38-C88 C-1 $0 $65,000 UTIL (21) 5 Land Rate Code 9006 OPEN/CULTIVATED INSUFNT R C-6 $0 $65,000 Apply for Ag Special Assessment Description Size Units Market Value LAND IMPROVEMENTS ONL Y (F 0 x 0 1 700 Click here to view the T ax Collector website. Sale Date SalePrice Grantee Land Only Sale Deed Type 1/1/1993 $0   C   Summary Parcel Number 206-00-02-010 Legal Description 10.0 AC - TR 1&2 - District 17 - City of Sumter Neighborhood S&W SUMTER, SUBURBAN Location Address 2434 WEDGEFIELD RD SUMTER 29154 Plat Book/Page PB|0000 Owners Valuation Land Miscellaneous Improvement Information T ax information Sales Sumter County, SC Sale date range: Search Sales by Neighborhood Sales by Area No data available for the following modules: Buildings, T ax History, Sketches. Recent Sales in Area From: 09/02/20 T o: 09/02/20 Distance: 1500 Units: Feet   Search Sales by Distance Map Sumter County makes every effort to produce the most accurate information possible. No warranties, expressed or implied, are provided for the data herein, its use or interpretation. |   User Privacy Policy |  GDPR Privacy Notice Last Data Upload: 9/1/2025, 9:27:59 PM Contact Us Developed by Reference Copy Duke Energy Business Services, LLC 0020991360 1330810 06/10/2025 Sumter, SC 29154 2434 Wedgefield Road SUMTER 33- 54- 45.9 N 080- 23- 36.0 W MTOWER FAA Chapters NONE Monopole Page 1 of 2 ATTN: Telecommunications Div, CS03A Duke Energy Business Services, LLC 401 South College Street Charlotte, NC 28202 56.0 37.8 93.8 N/A June 2021 FCC 854R UNITED STATES OF AMERICA FEDERAL COMMUNICATIONS COMMISSION ANTENNA STRUCTURE REGISTRATION OWNER: FCC Registration Number (FRN): Antenna Structure Registration Number Issue Date Location of Antenna Structure County: Ground Elevation (AMSL) meters Overall Height Above Ground (AGL) meters Latitude Longitude NAD83 Overall Height Above Mean Sea Level (AMSL) meters Center of Array Coordinates Type of Structure Painting and Lighting Requirements: Conditions: This registration is effective upon completion of the described antenna structur e and notification to the Commission. YOU MUST NOTIFY THE COMMISSION WITHIN 5 DAYS OF COMPLETION OF CONSTRUCTION OR CANCELLATION OF YOUR PROJECT, please file FCC Form 854. To file electronically, connect to the antenna structure registration system by pointing your web browser to https://www.fcc.gov/antenna-structure-registration. Electronic filing is required. Use purpose code “NT” for notification of completion of construction; use purpose code “CA” to cancel yo ur registration. The Antenna Structure Registration is not an authorization to construct radio facilities or transmit radio signals. It is necessary that all radio equipment on this structure be covered by a valid FCC license or construction permit. You must immediately provide a copy of this Registration to all tenant licensees and permittees sited on the structure described on this Registration (although not required, you may want to use Certified Mail to obtain proof of receipt), and display your Registration Number at the site. See reverse for important information about the Commission’s Antenna Structure Registration rules. Reference Copy Page 2 of 2 FCC 854R You must comply with all applicable FCC obstruction marking and lighting requirements, as set forth in Part 17 of the Commission’s Rules (47 C.F.R. Part 17). These rules include, but are not limited to: • Posting the Registration Number: The Antenna Structure Registration Number must be displayed in a conspicuous place so that it is readily visible near the base of the antenna structure. Materials used to display the Registration Number must be weather-resistant and of sufficient size to be easily seen at the base of the antenna structure. Exceptions exist for certain historic structures. See 47 C.F. R. 17.4(g)-(h). • Inspecting lights and equipment: The obstruction lighting must be observed at least every 24 hours in order to detect any outages or malfunctions. Lighting equipment, indicators, and associated devices must be inspected at least once every three months. • Reporting outages and malfunctions: When any top steady-burning light or a flashing light (in any position) burns out or malfunctions, the outage must be reported to the nearest FAA Flight Service Station, unless corrected within 30 minutes. The FAA must again be notified when the light is restored. The owner must also maintain a log of these outages and malfunctions. • Maintaining assigned painting: The antenna structure must be repainted as often as necessary to maintain good visibility. • Complying with environmental rules: If you certified that grant of this registration would not have a significant environmental impact, you must nevertheless maintain all pertinent records and be ready to provide documentation supporting this certification and compliance with the rules, in the event that such information is requested by the Commission pursuant to 47 C.F.R. 1.1307(d). • Updating information: The owner must notify the FCC of proposed modifications to this structure; of any change in ownership; or, within 30 days of dismantlement of the structure. Copies of the Code of Federal Regulations (which contain the FCC’s antenna structure registration rules, 47 C.F.R Part 17) are available from the Government Printing Office (GPO). To purchase CFR volumes, call (202) 512-1800. For GPO Customer Service, call (202) 512-1803. For additional FCC information, consult the Antenna Homepage on the internet at https://www.fcc.gov/antenna-structure-registration or call (877) 480-3201 (TTY 717-338-2824). June 2021 PRELIMINARY NOT FOR CONSTRUCTION PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SITE ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SITE NAME: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: A CHECKED BY: PB DRAWN BY: YA COA: REV DATEDETAILS A 08/18/2025 PRELIMINARY 0 1 2 SCSMT017 SITE NUMBER: N NW W SW S SE E NE NNW WNW WSW SSW SSE ESE ENE NNE SITE PLAN C-1 1. SITE PLAN BASED ON GOOGLE EARTH AERIAL IMAGERY 2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD. ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT ASSUME RESPONSIBILITY FOR THIS CONTENT. NOTES N.T.S. SITE PLAN 1 & 2 C-2.2 3 & 4 C-2.2 1 & 2 C-2.1 3 & 4 C-2.1 FREEDOM BLVD WEDGEFIELD ROAD NORTH LOCATION SOUTH EAST LOCATION NORTH WEST LOCATION SOUTH WEST LOCATION PROPOSED SITE LOCATION GRIFFIN LN PRELIMINARY NOT FOR CONSTRUCTION PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SITE ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SITE NAME: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: A CHECKED BY: PB DRAWN BY: YA COA: REV DATEDETAILS A 08/18/2025 PRELIMINARY 0 1 2 SCSMT017 SITE NUMBER: ELEVATIONS C-2.1 N.T.S. 1 - EXISTING NORTHWESTELEVATION N.T.S. 2 - PROPOSED NORTHWEST ELEVATION N.T.S. 4 - PROPOSED SOUTHWEST ELEVATION N.T.S. 3 - EXISTING SOUTHWEST ELEVATION PROPOSED DUKE ENERGY 120'-0" MONOPOLE TOWER PRELIMINARY NOT FOR CONSTRUCTION PREPARED BY: 3227 WELLINGTON COURT RALEIGH, NC 27615 919-782-2710 www.ets-pllc.com PREPARED FOR: SEAL: SITE ADDRESS: 2434 WEDGEFIELD ROAD SUMTER, SC 29154 SITE NAME: SUMTER WEDGEFIELD ROAD 230 SUB LATITUDE/LONGITUDE: 33.912755°, -80.393316° SHEET #CURRENT REV #: ETS #: 24131425 SHEET TITLE: A CHECKED BY: PB DRAWN BY: YA COA: REV DATEDETAILS A 08/18/2025 PRELIMINARY 0 1 2 SCSMT017 SITE NUMBER: ELEVATIONS C-2.2 N.T.S. 1 - EXISTING NORTH ELEVATION N.T.S. 2 - PROPOSED NORTH ELEVATION N.T.S. 4 - PROPOSED SOUTHEAST ELEVATION N.T.S. 3 - EXISTING SOUTHEAST ELEVATION PROPOSED DUKE ENERGY 120'-0" MONOPOLE TOWER PROPOSED DUKE ENERGY 120'-0" MONOPOLE TOWER

Source: City of Sumter website. First collected Oct 24, 2026.