BOA-25-27, 2434 Wedgefield Rd. (City) - Staff Report
City of Sumter · Sumter County · Other
Open the original document More from City of Sumter
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Sumter City-County
Zoning Board of Appeals
October 8, 2025
BOA-25-27 2434 Wedgefield Rd (City)
The applicant (Duke Energy Progress, Inc.) is requesting that the
Sumter City-County Board of Zoning Appeals grant special
exception approval for the establishment of a +/- 120 ft. tall
monopole telecommunications tower in a residential zoning district
pursuant to Article 3, Exhibit 3-5: Permitted Uses in All Zoning
Districts; Article 5.b.2. Enumeration of Certain Hazardous and/or
Potentially Disruptive Land Development Activities; and Article
5.b.4: Communication Towers and Antennae of the City of Sumter
Zoning & Development Standards Ordinance. The
telecommunications tower is proposed to be located within the
area of an existing electrical utility substation on the property. The
property is located at 2434 Wedgefield Rd., is zoned Residential-15
(R-15), and is represented by TMS# 206-00-02-010.
2
Sumter City-County
Zoning Board of Appeals
October 8, 2025
BOA-25-27 2434 Wedgefield Rd
I. THE REQUEST
Applicant: Duke Energy Progress Inc.
Status of the Applicant: Authorized Agent
Request: Special Exception approval to establish a monopole
telecommunications tower on the property.
City Council Ward Ward 6
Location: 2434 Wedgefield Rd.
Present Use/Zoning: Duke Energy Electrical Substation / Residential-15 (R-15)
Tax Map Reference: 206-00-02-010
II. BACKGROUND
The applicant requests approval to construct a
120 ft. tall monopole telecommunications tower
on property addressed as 2434 Wedgefield Rd..
The location of the property indicated in red on
the map to the right. As shown in Figure 1 ,
one page 2 of this report. the proposed location
is near the front of the property and over 190
ft. from all property lines.
Duke Energy is requesting the placement of this
tower to enhance its internal communications.
The improved infrastructure will allow for
faster notification of power outages in the area
and more efficient coordination of response
efforts.
Telecommunications towers (NAICS 517) located within any residential zoning district are
required to be reviewed and approved as a Special Exception Use. Special Exceptions are to be
3
evaluated in accordance with Article 1.h.4.c and Article 3.b.4.a. and in accordance with Article
5.b.4. of the City of Sumter Zoning & Development Standards Ordinance:
Figure 1: Proposed tower placement location
Figure 2: Photo of existing conditions at Wedgefield Rd
4
The applicant has submitted the following information in support of the application, as required
under Article 5.b.4. These items are attached to this report as Exhibits 1 -9.
Items Needed Date of Submission (Description as Needed)
1. Specifications 7-18-25
2. Site Plan 7-18-25
3. Tower Location Map 7-18-25
• The property is owned by Duke Energy and is zoned R-15.
4. Antenna
Capacity/Wind Load 7-18-25
5. Antenna Ownership 7-18-25
6. Owner Authorization
7-18-25
• Duke owns the Property, and has previously developed it
with a substation
7. FCC License 7-18-25
8. Visual Impact
Analysis
7-18-25
• The proposed tower, antenna or accessory structure will be
placed on site in such a manner that it will minimize the
visual impact on the surrounding properties
9. Removal Agreement 8-14-25
10. Conditions Met
Staff evaluation: all Article 5 conditions appear to have been met,
subject to Board of Zoning Appeals Decision regarding Special
Exception.
Figure 3: Zoning Map
5
III. SPECIAL EXCEPTION REVIEW CRITERIA
In Residential-15 (R-15) zoning districts, telecommunication towers are special exception uses
requiring the review and approval of the Board of Zoning Appeals. Special exception requests
for telecommunications towers are evaluated in accordance with Article 1.h.4.c. and Article
5.b.4.
Article 1.h.4.c: Special Exceptions
2. Permits for Special Exceptions shall be evaluated by the Board of Zoning
Appeals on the basis of the following criteria:
a. That the Special Exception complies with all applicable development
standards contained elsewhere in this Ordinance, including landscaping and
bufferyards, off-street parking, and dimensional requirements;
Staff Review: The proposed tower will be located in an existing Duke Energy
Electrical Substation. Based on staff ’s evaluation, the site meets minimum
development standards applicable to the proposed commercial use, not including
the special design criteria in Article 5.b.4.
b. That the special exception will be in substantial harmony with the area in
which it is located;
Staff Review: The property is zoned Residential-15 (R-15) and is in the Suburban
Development Planning Area according to the 2040 Comprehensive Land Use
Plan. Staff is of the opinion that the construction of the proposed tower will be in
substantial harmony with the surrounding area , based on the existing utility
development on the property.
c. That the special exception will not discourage or negate the use of
surrounding property for use(s) permitted by right.
Staff Review: The proposed tower will be set back over 190 ft. from all property
lines and is not expected to cause any negative impacts that would discourage or
negate use of surrounding properties.
Article 5.b.4. Communication Towers and Antennas:
1. Location and Visual Impact: The proposed tower, antenna or accessory structure will
be placed on site in such a manner that it will minimize the visual impact on the
surrounding properties;
Staff Review: According to the visual impact analysis, the view of the tower from
surrounding property and right -of-way will be minimal. T he property is naturally
6
buffered by surrounding vegetation, which will serve as a visual screen, further
reducing its visibility.
2. Inability to locate on existing structures: The applicant must show that a proposed
antenna and equipment cannot be accommodated and function as required by applicable
regulations and the applicants’ technical design requirements without unreasonable
modifications on any existing structure or tower under control of applicant, or to locate
on an available and suitable nearby tower at reasonable costs (i.e., at or below local area
rent average);
Staff Review: The property is owned by Duke Energy, which has developed a n
electric substation on the site. The proposed tower would be an operational addition
to the existing facility, as it is specifically designed to interface with the substation
and enhance response times in the event of an emergency/power outage.
3. Necessity for location in residential district: The applicant must show that the portion
of the city and/or county intended to receive coverage cannot be adequately served by a
communications tower or antenna placed in a non- residential district for valid technical
reasons;
Staff Review: The property, acquired by Duke Energy in 1993, is zoned
Residential-15 (R-15). As previously mentioned, a Duke Energy electric utility
substation already exists on the site, which is a permitted by- right use in a
residential zone.
4. Public property or other private property not suitable: Prior to consideration of a
permit for location on private property which must be acquired, the applicant must show
that available publicly owned sites, and available privately owned sites occupied by a
compatible use, are unsuitable for operation of the facility under applicable
communications regulations and the applicant’s technical design requirements;
Staff Review: The subject property is owned by Duke Energy, and this tower is
specifically to serve the substation as part of Duke’s communications and
monitoring systems.
5. Design for multiple use: Applicants must show that a new tower is designed to
accommodate additional antennae equal to applicant’s present and future requirements;
Staff Review: According to the applicant, no additional antennas from other
telecommunications providers will be permitted due to operational security and
safety concerns, as the tower will be located within the electric substation and the
tower’s purpose is to facilitate the company’s communications with elements of
the electrical grid.
6. Safety Codes Met: Applicant must show that all applicable health, nuisance, fire,
building, and life safety code requirements are met;
7
Staff Review: The applicant must obtain all required building permits. The
Sumter City-County building inspections department will inspect the construction
project to ensure that code requirements are met.
7. Paint and illumination: A communications tower must not be painted or illuminated
unless otherwise required by state or federal regulations.
Staff Review: The tower will meet FCC and FAA requirements for visibility; no
other painting or illumination is proposed.
8. Distance from existing tower: A permit for a proposed tower site within 1,000 ft of an
existing tower shall not be issued unless the applicant certifies that the existing tower
does not meet the applicants structural specifications and design requirements, or that a
co-location agreement could not be obtained;
Staff Review: The unique nature of this tower, serving as a communications link
between Duke Energy’s facilities and the substation on the property, also means
that no existing tower in the vicinity is able to meet the applicant’s technical
specifications.
9. Indemnity and claims resolution: The applicant must show by certification from a
registered professional engineer that the proposed facility will contain only equipment
meeting FCC rules, and must file with the Zoning Administrator a written
indemnification of the city or county of Sumter and proof of liability insurance or
financial ability to respond to claims up to $1,000,000.00 in the aggregate which may
arise from the operation of the facilities during its life, at not cost to the city and county
and in a form approved by the City of County Attorneys.
Staff Review The applicant has submitted proof of adequate insurance.
10. Minimum Setback: A tower must be set back from all lot lines by a distance equal to the
district setback requirement or 100% of the tower height, whichever is greater;
Staff Review: The proposed tower is to be set back from all lot lines by a height
equal to or greater than 120 ft. (height of the tower).
11. Technical Assistance: Prior to issuing a permit, the Zoning Administrator may make use
of professional technical services to determine if the standards in Article 5.b.4.d. are met;
Not Applicable
12. Maintenance: The communications tower shall be maintained by common corrosion
control procedures so it continuously maintains a minimum visual impact on surrounding
properties.
8
Staff Review: the proposed tower will be maintained will be done by Duke
Energy.
IV. STAFF RECOMMENDATION
Staff recommends no additional conditions of approval if the Board makes the necessary findings
to approve this request.
V. DRAFT MOTIONS for BOA-25-27
A. I move the Zoning Board of Appeals approve BOA-25-27, subject to the findings of fact
and conclusions developed by the BZA and so stated:
B. I move the Zoning Board of Appeals deny BOA-25-27, subject to the following findings
of fact and conclusions:
C. I move the Zoning Board of Appeals enter an alternative motion for BOA-25-27.
VI. BOARD OF APPEALS – October 8, 2025
Date: 07/11/2025
Robert Jackson Engineered Tower Solutions, PLLC
Sr Telecom Analyst 3227 Wellington Court
Duke Energy Raleigh, NC 27615
910-523-8708 (919) 782-2710
Robert.Jackson3@duke-energy.com
Subject: Structural Analysis Report
Duke Energy Designation: Duke Energy Site Name: Sumter Wedgefield Road 230 Sub
Engineering Firm Designation: ETS, PLLC Job Number: 24131425.STR.3889
Site Data: 2434 Wedgefield Rd, Sumter, Sumter County, SC 29154
Latitude 33.912755°, Longitude -80.393316°
140-ft Valmont H10 (Direct Bury 120-ft AGL) – Monopole
Dear Robert Jackson,
Engineered Tower Solutions, PLLC is pleased to submit this “Structural Analysis Report” to determine the
structural integrity of the above-mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have
determined the tower stress level for the structure and foundation, under the following load case, to be:
Final Equipment Configuration: Tower: 89.8% Sufficient Capacity
Foundation: 101.9% Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 133 mph as required by the 2021 International
Building Code. Applicable Standard references and design criteria are listed in Section 2 – Analysis Criteria.
Structural Analysis Report prepared by:
J. Scott Hilgoe, PE
Structural Engineering Manager
Respectfully submitted by:
Christopher G. Ply, PE, SE
President / CEO
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 2
tnxTower Report - version 8.3.1.2
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 - Tower Component Stresses vs. Capacity
4.1) Recommendations
4.2) Dish Deflection Table
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Pole Design Specifications
7) APPENDIX C
Additional Calculations
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 3
tnxTower Report - version 8.3.1.2
1) INTRODUCTION
This tower is a proposed 140-ft Valmont Class H10 direct-embedded monopole tower designed by Valmont.
This pole is to be embedded 20-ft for a final height above grade of 120-ft. The embedded pole has been designed
considering a surrounding gravel annulus of 12” larger than the bottom pole diameter.
2) ANALYSIS CRITERIA
Building Code: 2018 IBC
TIA-222 Revision: TIA-222-H
Risk Category: III
Wind Speed: 133 mph
Exposure Category: C
Topographic Factor: 1
Ice Thickness: 1.0 in
Wind Speed With Ice: 30 mph
Service Wind Speed:
Ss:
S1:
60 mph
0.384
0.128
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed Line
Size (in)
118.0
(Duke
Energy)
118.0
1 Radiowaves HPD4-5.2
1
CAT5E
1 Cambium PMP450I Non-Integrated
2 Tower Mounts Stiff Arm/Stabilizer Bar
1 SitePro 1 DCH8 Chain Mount
1 Tower Mount 2.375"ø x 2-ft Pipe Mount
1 Tower Mount 4.5"ø x 5-ft Pipe Mount
Table 2 - Other Considered Equipment
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed Line
Size (in)
60.0 *
(Future) 60.0
9 JMA X7CQAP-86-880-VR0
15 1-5/8
Hybrid
9 Ericsson RRUS 32
3 Raycap DC6-48-60-18-8C
1 Perfect-Vision PV-LPPGS-12M-HR2-AP19-AT
(12.5 ft Platform Mount)
*Future LTE loading considered in this analysis.
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 4
tnxTower Report - version 8.3.1.2
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
Document Remarks Reference Source
Tower Design Drawings/Pole
Specifications
Valmont H10 SW10 CS78231
(Drawing No. 307137Z) 01/19/2021 On File
Path Study Cambium Networks Link Planner
(Proj. DEP 04-04-23_png) 10/28/2024 On File
Geotechnical Report ETS, PLLC
(Job Number: 24131425) 06/19/2025 On File
3.1) Analysis Method
tnxTower (version 8.3.1.2), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built and have been maintained in accordance with the
manufacturer’s specifications.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Table(s) 1 and 2 and the referenced drawings.
3) The proposed cables were assumed to be banded to the exterior of the pole.
This analysis may be affected if any assumptions are not valid or have been made in error.
Engineered Tower Solutions, PLLC should be notified to determine the effect on the structural
integrity of the tower.
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 5
tnxTower Report - version 8.3.1.2
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K)
%
Capacity Pass / Fail
L1 120 - 67.0833 Pole TP26.08x16.51x0.22 1 -2.715 1035.760 29.9 Pass
L2 67.0833 -
31.6667
Pole TP32.05x24.89x0.25 2 -10.305 1456.360 64.6 Pass
L3 31.6667 - 0 Pole TP37.28x30.68x0.28 3 -16.608 1958.240 89.8 Pass
Summary
Pole (L3) 89.8 Pass
RATING = 89.8 Pass
Table 5 - Tower Component Stresses vs. Capacity
Notes Component Elevation (ft) % Capacity Pass / Fail
1 Embedded Pole
Foundation 0 91.4 Pass
1,2 Base Foundation Soil
Interaction 0 101.9 Pass
Structure Rating (max from all components) = 101.9% 2
Notes:
1) See additional documentation in “Appendix C - Additional Calculations” for calculations supporting the % capacity
consumed.
2) Capacity usage up to 105% is considered acceptable.
4.1) Recommendations
The tower and its foundation have sufficient capacity to carry the final load configuration. No
modifications are required at this time.
4.2) Proposed Dish Antenna Deflection Results
As requested, the results of the tilt and twist values for a 60 mph 3-second gust service wind speed per
the TIA-222-H standard are given below:
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
118.00 HPD4-5.2 48 13.00 0.81 0.01 104440
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 6
tnxTower Report - version 8.3.1.2
APPENDIX A
TNXTOWER OUTPUT
ETS, PLLC
3227 Wellington Court
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Job:
Sumter Wedgefield Road 230 Sub
Project: ETS, PLLC Job No.24131425.STR.3889
Client: Duke Energy Drawn by: J. Scott Hilgoe, PE App'd:
Code: TIA-222-H Date: 07/11/25 Scale: NTS
Path:
C:\Users\scott.hilgoe.ETS\OneDrive - Engineered Tower Solutions\Desktop\Working Folder\Duke\Sumter Wedgefield\Analysis\Tower\Sumter Wedgefield.eri
Dwg No. E-1
120.0 ft
67.1 ft
31.7 ft
0.0 ft
REACTIONS - 133 mph WIND
TORQUE 3 kip-ft
22 K
SHEAR
1359 kip-ft
MOMENT
17 K
AXIAL
30 mph WIND - 1.00 in ICE
TORQUE 0 kip-ft
1 K
SHEAR
94 kip-ft
MOMENT
30 K
AXIAL
ARE FACTORED
ALL REACTIONS
Section 123
Length (ft) 52.9239.5836.50
Number of Sides 121212
Thickness (in) 0.220.250.28
Socket Length (ft) 4.174.83
Top Dia (in) 16.5124.8930.68
Bot Dia (in) 26.0832.0537.28
Grade A572-65
Weight (K) 2.73.13.89.5
1/2-in x 4-ft Lightning Rod 120 4.5" x 5-ft Pipe Mount w/ DCH8 Chain
Mount
118 2.4" x 2-ft Pipe Mount 118 (2) Pipe Mount/Stabilizer 118 PMP 450I 118 HPD4-5.2 118 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) X7CQAP-86-880-VR0_TIA 60 (3) RRUS 32 60 (3) RRUS 32 60 (3) RRUS 32 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 DC6-48-60-18-8C 60 PV-LPPGS-12M-HR2-AP19 60DESIGNED APPURTENANCE LOADING
TYPE TYPEELEVATION ELEVATION
1/2-in x 4-ft Lightning Rod 120
4.5" x 5-ft Pipe Mount w/ DCH8 Chain
Mount
118
2.4" x 2-ft Pipe Mount 118
(2) Pipe Mount/Stabilizer 118
PMP 450I 118
HPD4-5.2 118
(3) X7CQAP-86-880-VR0_TIA 60
(3) X7CQAP-86-880-VR0_TIA 60
(3) X7CQAP-86-880-VR0_TIA 60
(3) RRUS 32 60
(3) RRUS 32 60
(3) RRUS 32 60
DC6-48-60-18-8C 60
DC6-48-60-18-8C 60
DC6-48-60-18-8C 60
PV-LPPGS-12M-HR2-AP19 60
MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A572-65 65 ksi 80 ksi
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 133 mph basic wind in accordance with the TIA-222-H Standard.
3. Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to
increase in thickness with height.
4. Deflections are based upon a 60 mph wind.
5. Tower Risk Category III.
6. Topographic Category 1 with Crest Height of 0.00 ft
7. TOWER RATING: 89.8%
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
1 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Tower Input Data
The tower is a monopole.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower base elevation above sea level: 183.87 ft.
Basic wind speed of 133 mph.
Risk Category III.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0.00 ft.
Nominal ice thickness of 1.00 in.
Ice thickness is considered to increase with height.
Ice density of 56 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50 °F.
Deflections calculated using a wind speed of 60 mph.
Non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Assume Legs Pinned Calculate Redundant Bracing Forces
Consider Moments - Horizontals √ Assume Rigid Index Plate Ignore Redundant Members in FEA
Consider Moments - Diagonals √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
Use Moment Magnification Use Clear Spans For KL/r All Leg Panels Have Same Allowable
√ Use Code Stress Ratios Retension Guys To Initial Tension Offset Girt At Foundation
√ Use Code Safety Factors - Guys √ Bypass Mast Stability Checks √ Consider Feed Line Torque
Escalate Ice √ Use Azimuth Dish Coefficients Include Angle Block Shear Check
Always Use Max Kz √ Project Wind Area of Appurtenances Use TIA-222-H Bracing Resist. Exemption
Kz In Exposure D Hurricane Region Alternative Appurt. EPA Calculation Use TIA-222-H Tension Splice Exemption
Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
Leg Bolts Are At Top Of Section Add IBC .6D+W Combination √ Include Shear-Torsion Interaction
Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Pole Without Linear Attachments
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole With Shroud Or No Appurtenances
Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Outside and Inside Corner Radii Are Known
Use Special Wind Profile
Tapered Pole Section Geometry
Section Elevation
ft
Section
Length
ft
Splice
Length
ft
Number
of
Sides
Top
Diameter
in
Bottom
Diameter
in
Wall
Thickness
in
Bend
Radius
in
Pole Grade
L1 120.00-67.08 52.92 4.17 12 16.51 26.08 0.22 0.88 A572-65
(65 ksi)
L2 67.08-31.67 39.58 4.83 12 24.89 32.05 0.25 1.00 A572-65
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
2 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Section Elevation
ft
Section
Length
ft
Splice
Length
ft
Number
of
Sides
Top
Diameter
in
Bottom
Diameter
in
Wall
Thickness
in
Bend
Radius
in
Pole Grade
(65 ksi)
L3 31.67-0.00 36.50 12 30.68 37.28 0.28 1.12 A572-65
(65 ksi)
Tapered Pole Properties
Section Tip Dia.
in
Area
in2
I
in4
r
in
C
in
I/C
in3
J
in4
It/Q
in2
w
in
w/t
L1 17.02 11.49 389.16 5.83 8.55 45.50 788.55 5.65 3.84 17.524
26.92 18.24 1556.76 9.26 13.51 115.24 3154.42 8.98 6.40 29.235
L2 26.46 19.83 1536.82 8.82 12.89 119.21 3114.01 9.76 6.00 24
33.09 25.60 3304.18 11.38 16.60 199.02 6695.16 12.60 7.92 31.678
L3 32.56 27.50 3242.91 10.88 15.89 204.09 6571.01 13.54 7.47 26.576
38.49 33.47 5847.83 13.24 19.31 302.85 11849.29 16.48 9.24 32.872
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
L1
120.00-67.08
1 1 1
L2 67.08-31.67 1 1 1
L3 31.67-0.00 1 1 1
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude
From
Torque
Calculation
Component
Type
Placement
ft
Total
Number
Number
Per Row
Start/End
Position
Width or
Diameter
in
Perimeter
in
Weight
plf
***
Safety Line 3/8 C No Surface Ar
(CaAa)
120.00 -
5.00
1 1 0.000
0.000
0.38 0.22
Step Pegs (5/8'' SR) 7-in.
w/ 30'' Step
C No Surface Ar
(CaAa)
120.00 -
5.00
2 2 0.000
0.000
0.35 0.49
***
CAT5E(1/4) A No Surface Ar
(CaAa)
118.00 -
5.00
1 1 -0.100
0.100
0.25 0.10
***
1 5/8 C No Surface Ar
(CaAa)
60.00 - 5.00 15 8 -0.100
0.100
1.98 1.04
***
Feed Line/Linear Appurtenances - Entered As Area
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
3 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Component
Type
Placement
ft
Total
Number
C AAA
ft2/ft
Weight
plf
***
Feed Line/Linear Appurtenances Section Areas
Tower
Section
Tower
Elevation
ft
Face A R
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
L1 120.00-67.08 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
1.273
0.000
5.689
0.000
0.000
0.000
0.005
0.000
0.063
L2 67.08-31.67 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.885
0.000
48.687
0.000
0.000
0.000
0.004
0.000
0.484
L3 31.67-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.667
0.000
45.107
0.000
0.000
0.000
0.003
0.000
0.448
Feed Line/Linear Appurtenances Section Areas - With Ice
Tower
Section
Tower
Elevation
ft
Face
or
Leg
Ice
Thickness
in
AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
L1 120.00-67.08 A
B
C
1.274 0.000
0.000
0.000
0.000
0.000
0.000
14.247
0.000
36.954
0.000
0.000
0.000
0.126
0.000
0.352
L2 67.08-31.67 A
B
C
1.197 0.000
0.000
0.000
0.000
0.000
0.000
9.910
0.000
89.858
0.000
0.000
0.000
0.088
0.000
2.260
L3 31.67-0.00 A
B
C
1.068 0.000
0.000
0.000
0.000
0.000
0.000
7.048
0.000
78.468
0.000
0.000
0.000
0.059
0.000
2.028
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
L1 120.00-67.08 -0.12 0.55 -0.67 1.61
L2 67.08-31.67 -0.08 6.34 -0.51 5.95
L3 31.67-0.00 -0.07 6.57 -0.46 6.37
Note: For pole sections, center of pressure calculations do not consider feed line shielding.
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
4 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
L1 2 Safety Line 3/8 67.08 - 120.00 1.0000 1.0000
L1 3 Step Pegs (5/8'' SR) 7-in. w/
30'' Step
67.08 - 120.00 1.0000 1.0000
L1 6 CAT5E(1/4) 67.08 - 118.00 1.0000 1.0000
L2 2 Safety Line 3/8 31.67 - 67.08 1.0000 1.0000
L2 3 Step Pegs (5/8'' SR) 7-in. w/
30'' Step
31.67 - 67.08 1.0000 1.0000
L2 6 CAT5E(1/4) 31.67 - 67.08 1.0000 1.0000
L2 8 1 5/8 31.67 - 60.00 1.0000 1.0000
L3 2 Safety Line 3/8 5.00 - 31.67 1.0000 1.0000
L3 3 Step Pegs (5/8'' SR) 7-in. w/
30'' Step
5.00 - 31.67 1.0000 1.0000
L3 6 CAT5E(1/4) 5.00 - 31.67 1.0000 1.0000
L3 8 1 5/8 5.00 - 31.67 1.0000 1.0000
Discrete Tower Loads
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustment
°
Placement
ft
C AAA
Front
ft2
CAAA
Side
ft2
Weight
K
***
1/2-in x 4-ft Lightning Rod A From Leg 0.00
0.00
2.00
0.00 120.00 No Ice
1/2'' Ice
1'' Ice
0.20
0.61
0.95
0.20
0.61
0.95
0.003
0.005
0.010
***
4.5'' x 5-ft Pipe Mount w/
DCH8 Chain Mount
C From Leg 1.00
0.00
0.00
0.00 118.00 No Ice
1/2'' Ice
1'' Ice
1.48
2.08
2.40
1.48
2.08
2.40
0.000
0.000
0.000
2.4'' x 2-ft Pipe Mount C From Leg 1.00
0.00
0.00
0.00 118.00 No Ice
1/2'' Ice
1'' Ice
0.34
0.47
0.61
0.34
0.47
0.61
0.000
0.000
0.000
(2) Pipe Mount/Stabilizer C From Leg 0.50
0.00
0.00
0.00 118.00 No Ice
1/2'' Ice
1'' Ice
0.42
0.57
0.73
0.42
0.57
0.73
0.000
0.000
0.000
PMP 450I C From Leg 1.00
0.00
0.00
0.00 118.00 No Ice
1/2'' Ice
1'' Ice
1.62
1.90
2.18
0.96
1.20
1.47
0.015
0.031
0.049
***
PV-LPPGS-12M-HR2-AP19 C None 0.00 60.00 No Ice
1/2'' Ice
1'' Ice
19.00
25.60
32.20
19.00
25.60
32.20
2.000
2.400
2.800
(3)
X7CQAP-86-880-VR0_TIA
A From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
13.44
14.04
14.65
9.06
9.66
10.26
0.072
0.153
0.242
(3)
X7CQAP-86-880-VR0_TIA
B From Leg 4.00
0.00
0.00 60.00 No Ice
1/2'' Ice
13.44
14.04
9.06
9.66
0.072
0.153
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
5 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustment
°
Placement
ft
C AAA
Front
ft2
CAAA
Side
ft2
Weight
K
0.00 1'' Ice 14.65 10.26 0.242
(3)
X7CQAP-86-880-VR0_TIA
C From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
13.44
14.04
14.65
9.06
9.66
10.26
0.072
0.153
0.242
(3) RRUS 32 A From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
2.86
3.08
3.32
1.78
1.97
2.17
0.055
0.077
0.103
(3) RRUS 32 B From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
2.86
3.08
3.32
1.78
1.97
2.17
0.055
0.077
0.103
(3) RRUS 32 C From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
2.86
3.08
3.32
1.78
1.97
2.17
0.055
0.077
0.103
DC6-48-60-18-8C A From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
1.14
1.79
2.00
1.14
1.79
2.00
0.026
0.047
0.070
DC6-48-60-18-8C B From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
1.14
1.79
2.00
1.14
1.79
2.00
0.026
0.047
0.070
DC6-48-60-18-8C C From Leg 4.00
0.00
0.00
0.00 60.00 No Ice
1/2'' Ice
1'' Ice
1.14
1.79
2.00
1.14
1.79
2.00
0.026
0.047
0.070
***
Dishes
Description Face
or
Leg
Dish
Type
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
Azimuth
Adjustment
°
3 dB
Beam
Width
°
Elevation
ft
Outside
Diameter
ft
Aperture
Area
ft2
Weight
K
***
HPD4-5.2 B Paraboloid
w/Shroud (HP)
From
Leg
1.00
0.00
0.00
-16.46 118.00 4.00 No Ice
1/2'' Ice
1'' Ice
12.57
13.10
13.62
0.090
0.150
0.220
***
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice
3 0.9 Dead+1.0 Wind 0 deg - No Ice
4 1.2 Dead+1.0 Wind 30 deg - No Ice
5 0.9 Dead+1.0 Wind 30 deg - No Ice
6 1.2 Dead+1.0 Wind 60 deg - No Ice
7 0.9 Dead+1.0 Wind 60 deg - No Ice
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
6 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Comb.
No.
Description
8 1.2 Dead+1.0 Wind 90 deg - No Ice
9 0.9 Dead+1.0 Wind 90 deg - No Ice
10 1.2 Dead+1.0 Wind 120 deg - No Ice
11 0.9 Dead+1.0 Wind 120 deg - No Ice
12 1.2 Dead+1.0 Wind 150 deg - No Ice
13 0.9 Dead+1.0 Wind 150 deg - No Ice
14 1.2 Dead+1.0 Wind 180 deg - No Ice
15 0.9 Dead+1.0 Wind 180 deg - No Ice
16 1.2 Dead+1.0 Wind 210 deg - No Ice
17 0.9 Dead+1.0 Wind 210 deg - No Ice
18 1.2 Dead+1.0 Wind 240 deg - No Ice
19 0.9 Dead+1.0 Wind 240 deg - No Ice
20 1.2 Dead+1.0 Wind 270 deg - No Ice
21 0.9 Dead+1.0 Wind 270 deg - No Ice
22 1.2 Dead+1.0 Wind 300 deg - No Ice
23 0.9 Dead+1.0 Wind 300 deg - No Ice
24 1.2 Dead+1.0 Wind 330 deg - No Ice
25 0.9 Dead+1.0 Wind 330 deg - No Ice
26 1.2 Dead+1.0 Ice+1.0 Temp
27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp
28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp
29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp
30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp
31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp
32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp
33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp
34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp
35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp
36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp
37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp
38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp
39 Dead+Wind 0 deg - Service
40 Dead+Wind 30 deg - Service
41 Dead+Wind 60 deg - Service
42 Dead+Wind 90 deg - Service
43 Dead+Wind 120 deg - Service
44 Dead+Wind 150 deg - Service
45 Dead+Wind 180 deg - Service
46 Dead+Wind 210 deg - Service
47 Dead+Wind 240 deg - Service
48 Dead+Wind 270 deg - Service
49 Dead+Wind 300 deg - Service
50 Dead+Wind 330 deg - Service
Maximum Member Forces
Section
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-ft
Minor Axis
Moment
kip-ft
L1 120 - 67.0833 Pole Max Tension 2 0.000 0.00 -0.00
Max. Compression 26 -5.453 -0.19 -0.55
Max. Mx 20 -2.715 174.50 6.15
Max. My 14 -2.780 -9.91 -151.94
Max. Vy 20 -6.293 174.50 6.15
Max. Vx 14 5.797 -9.91 -151.94
Max. Torque 5 -1.02
L2 67.0833 -
31.6667
Pole Max Tension 1 0.000 0.00 0.00
Max. Compression 26 -20.297 -0.10 -3.59
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
7 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Section
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-ft
Minor Axis
Moment
kip-ft
Max. Mx 20 -10.305 626.47 10.30
Max. My 14 -10.411 -17.41 -573.06
Max. Vy 20 -17.618 626.47 10.30
Max. Vx 14 16.185 -17.41 -573.06
Max. Torque 9 -3.49
L3 31.6667 - 0 Pole Max Tension 1 0.000 0.00 0.00
Max. Compression 26 -29.800 -0.02 -7.53
Max. Mx 20 -16.608 1359.15 14.27
Max. My 14 -16.612 -25.13 -1239.41
Max. Vy 20 -22.367 1359.15 14.27
Max. Vx 14 20.164 -25.13 -1239.41
Max. Torque 9 -3.48
Maximum Reactions
Location Condition Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Pole Max. Vert 26 29.800 0.000 0.001
Max. Hx 21 12.472 22.351 0.134
Max. Hz 3 12.472 0.213 20.125
Max. Mx 2 1232.57 0.213 20.125
Max. Mz 8 1334.68 -22.147 -0.092
Max. Torsion 21 3.39 22.351 0.134
Min. Vert 15 12.472 -0.206 -20.149
Min. Hx 8 16.630 -22.147 -0.092
Min. Hz 14 16.630 -0.206 -20.150
Min. Mx 14 -1239.41 -0.206 -20.150
Min. Mz 20 -1359.15 22.351 0.134
Min. Torsion 9 -3.48 -22.146 -0.092
Tower Mast Reaction Summary
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Dead Only 13.858 -0.000 -0.000 1.58 -0.10 0.00
1.2 Dead+1.0 Wind 0 deg - No
Ice
16.630 -0.213 -20.125 -1232.57 25.73 0.37
0.9 Dead+1.0 Wind 0 deg - No
Ice
12.472 -0.213 -20.125 -1226.60 25.58 0.37
1.2 Dead+1.0 Wind 30 deg - No
Ice
16.630 10.285 -17.361 -1058.92 -644.39 -1.66
0.9 Dead+1.0 Wind 30 deg - No
Ice
12.472 10.285 -17.361 -1053.83 -640.90 -1.66
1.2 Dead+1.0 Wind 60 deg - No
Ice
16.630 18.256 -10.150 -602.72 -1129.43 0.92
0.9 Dead+1.0 Wind 60 deg - No
Ice
12.472 18.256 -10.150 -600.08 -1123.39 0.92
1.2 Dead+1.0 Wind 90 deg - No
Ice
16.630 22.147 0.092 13.08 -1334.68 3.48
0.9 Dead+1.0 Wind 90 deg - No
Ice
12.472 22.146 0.092 12.51 -1327.62 3.48
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
8 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
1.2 Dead+1.0 Wind 120 deg -
No Ice
16.630 18.215 10.380 634.44 -1124.36 0.40
0.9 Dead+1.0 Wind 120 deg -
No Ice
12.472 18.215 10.380 630.62 -1118.35 0.40
1.2 Dead+1.0 Wind 150 deg -
No Ice
16.630 10.431 17.375 1064.48 -662.00 -2.64
0.9 Dead+1.0 Wind 150 deg -
No Ice
12.472 10.431 17.375 1058.40 -658.40 -2.64
1.2 Dead+1.0 Wind 180 deg -
No Ice
16.630 0.206 20.150 1239.41 -25.13 -0.60
0.9 Dead+1.0 Wind 180 deg -
No Ice
12.472 0.206 20.149 1232.34 -24.92 -0.60
1.2 Dead+1.0 Wind 210 deg -
No Ice
16.630 -10.324 17.318 1057.60 648.76 1.93
0.9 Dead+1.0 Wind 210 deg -
No Ice
12.472 -10.324 17.318 1051.56 645.31 1.93
1.2 Dead+1.0 Wind 240 deg -
No Ice
16.630 -18.431 10.132 604.38 1150.25 -0.63
0.9 Dead+1.0 Wind 240 deg -
No Ice
12.472 -18.430 10.132 600.77 1144.12 -0.63
1.2 Dead+1.0 Wind 270 deg -
No Ice
16.630 -22.351 -0.134 -14.27 1359.15 -3.39
0.9 Dead+1.0 Wind 270 deg -
No Ice
12.472 -22.351 -0.134 -14.65 1352.03 -3.39
1.2 Dead+1.0 Wind 300 deg -
No Ice
16.630 -18.417 -10.442 -638.17 1148.60 -0.72
0.9 Dead+1.0 Wind 300 deg -
No Ice
12.472 -18.417 -10.442 -635.27 1142.48 -0.72
1.2 Dead+1.0 Wind 330 deg -
No Ice
16.630 -10.598 -17.426 -1066.71 682.01 2.16
0.9 Dead+1.0 Wind 330 deg -
No Ice
12.472 -10.598 -17.426 -1061.56 678.32 2.16
1.2 Dead+1.0 Ice+1.0 Temp 29.800 -0.000 -0.001 7.53 -0.02 0.00
1.2 Dead+1.0 Wind 0 deg+1.0
Ice+1.0 Temp
29.800 -0.012 -1.368 -78.59 1.46 0.01
1.2 Dead+1.0 Wind 30 deg+1.0
Ice+1.0 Temp
29.800 0.696 -1.181 -66.56 -44.66 -0.09
1.2 Dead+1.0 Wind 60 deg+1.0
Ice+1.0 Temp
29.800 1.204 -0.673 -34.12 -77.01 0.05
1.2 Dead+1.0 Wind 90 deg+1.0
Ice+1.0 Temp
29.800 1.385 0.005 8.26 -88.30 0.19
1.2 Dead+1.0 Wind 120
deg+1.0 Ice+1.0 Temp
29.800 1.201 0.686 50.96 -76.72 0.03
1.2 Dead+1.0 Wind 150
deg+1.0 Ice+1.0 Temp
29.800 0.705 1.182 81.90 -45.67 -0.12
1.2 Dead+1.0 Wind 180
deg+1.0 Ice+1.0 Temp
29.800 0.011 1.369 94.00 -1.45 -0.02
1.2 Dead+1.0 Wind 210
deg+1.0 Ice+1.0 Temp
29.800 -0.699 1.179 81.51 44.89 0.10
1.2 Dead+1.0 Wind 240
deg+1.0 Ice+1.0 Temp
29.800 -1.213 0.672 49.24 78.17 -0.03
1.2 Dead+1.0 Wind 270
deg+1.0 Ice+1.0 Temp
29.800 -1.396 -0.007 6.70 89.68 -0.18
1.2 Dead+1.0 Wind 300
deg+1.0 Ice+1.0 Temp
29.800 -1.213 -0.689 -36.15 78.08 -0.05
1.2 Dead+1.0 Wind 330
deg+1.0 Ice+1.0 Temp
29.800 -0.714 -1.185 -67.01 46.79 0.10
Dead+Wind 0 deg - Service 13.858 -0.039 -3.669 -222.83 4.59 0.07
Dead+Wind 30 deg - Service 13.858 1.875 -3.165 -191.24 -117.21 -0.30
Dead+Wind 60 deg - Service 13.858 3.328 -1.850 -108.32 -205.38 0.17
Dead+Wind 90 deg - Service 13.858 4.037 0.017 3.63 -242.71 0.64
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
9 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Dead+Wind 120 deg - Service 13.858 3.321 1.892 116.59 -204.46 0.07
Dead+Wind 150 deg - Service 13.858 1.902 3.168 194.76 -120.41 -0.48
Dead+Wind 180 deg - Service 13.858 0.038 3.674 226.56 -4.64 -0.11
Dead+Wind 210 deg - Service 13.858 -1.882 3.157 193.51 117.84 0.35
Dead+Wind 240 deg - Service 13.858 -3.360 1.847 111.14 209.00 -0.12
Dead+Wind 270 deg - Service 13.858 -4.074 -0.024 -1.33 247.00 -0.62
Dead+Wind 300 deg - Service 13.858 -3.357 -1.904 -114.76 208.71 -0.13
Dead+Wind 330 deg - Service 13.858 -1.932 -3.177 -192.66 123.88 0.40
Solution Summary
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
1 0.000 -13.858 0.000 0.000 13.858 0.000 0.000%
2 -0.213 -16.630 -20.127 0.213 16.630 20.125 0.007%
3 -0.213 -12.472 -20.127 0.213 12.472 20.125 0.006%
4 10.286 -16.630 -17.361 -10.285 16.630 17.361 0.001%
5 10.286 -12.472 -17.361 -10.285 12.472 17.361 0.001%
6 18.257 -16.630 -10.150 -18.256 16.630 10.150 0.001%
7 18.257 -12.472 -10.150 -18.256 12.472 10.150 0.001%
8 22.147 -16.630 0.092 -22.147 16.630 -0.092 0.001%
9 22.147 -12.472 0.092 -22.146 12.472 -0.092 0.002%
10 18.215 -16.630 10.380 -18.215 16.630 -10.380 0.001%
11 18.215 -12.472 10.380 -18.215 12.472 -10.380 0.001%
12 10.431 -16.630 17.375 -10.431 16.630 -17.375 0.001%
13 10.431 -12.472 17.375 -10.431 12.472 -17.375 0.000%
14 0.206 -16.630 20.151 -0.206 16.630 -20.150 0.003%
15 0.206 -12.472 20.151 -0.206 12.472 -20.149 0.006%
16 -10.324 -16.630 17.318 10.324 16.630 -17.318 0.001%
17 -10.324 -12.472 17.318 10.324 12.472 -17.318 0.001%
18 -18.431 -16.630 10.132 18.431 16.630 -10.132 0.001%
19 -18.431 -12.472 10.132 18.430 12.472 -10.132 0.001%
20 -22.352 -16.630 -0.134 22.351 16.630 0.134 0.003%
21 -22.352 -12.472 -0.134 22.351 12.472 0.134 0.002%
22 -18.417 -16.630 -10.443 18.417 16.630 10.442 0.001%
23 -18.417 -12.472 -10.443 18.417 12.472 10.442 0.001%
24 -10.598 -16.630 -17.426 10.598 16.630 17.426 0.001%
25 -10.598 -12.472 -17.426 10.598 12.472 17.426 0.001%
26 0.000 -29.800 0.000 0.000 29.800 0.001 0.003%
27 -0.012 -29.800 -1.369 0.012 29.800 1.368 0.002%
28 0.697 -29.800 -1.181 -0.696 29.800 1.181 0.002%
29 1.204 -29.800 -0.673 -1.204 29.800 0.673 0.002%
30 1.385 -29.800 0.005 -1.385 29.800 -0.005 0.002%
31 1.202 -29.800 0.686 -1.201 29.800 -0.686 0.002%
32 0.705 -29.800 1.182 -0.705 29.800 -1.182 0.002%
33 0.011 -29.800 1.370 -0.011 29.800 -1.369 0.002%
34 -0.699 -29.800 1.179 0.699 29.800 -1.179 0.002%
35 -1.214 -29.800 0.672 1.213 29.800 -0.672 0.002%
36 -1.397 -29.800 -0.007 1.396 29.800 0.007 0.002%
37 -1.213 -29.800 -0.690 1.213 29.800 0.689 0.002%
38 -0.714 -29.800 -1.185 0.714 29.800 1.185 0.002%
39 -0.039 -13.858 -3.670 0.039 13.858 3.669 0.005%
40 1.875 -13.858 -3.166 -1.875 13.858 3.165 0.005%
41 3.329 -13.858 -1.851 -3.328 13.858 1.850 0.005%
42 4.038 -13.858 0.017 -4.037 13.858 -0.017 0.005%
43 3.321 -13.858 1.893 -3.321 13.858 -1.892 0.005%
44 1.902 -13.858 3.168 -1.902 13.858 -3.168 0.005%
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
10 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
45 0.038 -13.858 3.674 -0.038 13.858 -3.674 0.005%
46 -1.882 -13.858 3.158 1.882 13.858 -3.157 0.005%
47 -3.360 -13.858 1.847 3.360 13.858 -1.847 0.005%
48 -4.075 -13.858 -0.024 4.074 13.858 0.024 0.005%
49 -3.358 -13.858 -1.904 3.357 13.858 1.904 0.005%
50 -1.932 -13.858 -3.177 1.932 13.858 3.177 0.005%
Non-Linear Convergence Results
Load
Combination
Converged? Number
of Cycles
Displacement
Tolerance
Force
Tolerance
1 Yes 6 0.00000001 0.00000001
2 Yes 13 0.00010213 0.00011678
3 Yes 13 0.00007325 0.00009346
4 Yes 16 0.00000001 0.00007378
5 Yes 15 0.00000001 0.00012719
6 Yes 16 0.00000001 0.00007333
7 Yes 15 0.00000001 0.00012612
8 Yes 15 0.00000001 0.00006878
9 Yes 14 0.00000001 0.00011683
10 Yes 16 0.00000001 0.00008547
11 Yes 15 0.00000001 0.00014695
12 Yes 16 0.00000001 0.00009205
13 Yes 16 0.00000001 0.00006989
14 Yes 14 0.00004418 0.00007166
15 Yes 13 0.00007321 0.00012251
16 Yes 16 0.00000001 0.00008479
17 Yes 15 0.00000001 0.00014661
18 Yes 16 0.00000001 0.00008590
19 Yes 15 0.00000001 0.00014788
20 Yes 14 0.00004377 0.00012268
21 Yes 14 0.00000001 0.00009555
22 Yes 16 0.00000001 0.00008496
23 Yes 15 0.00000001 0.00014584
24 Yes 16 0.00000001 0.00008210
25 Yes 15 0.00000001 0.00014130
26 Yes 8 0.00000001 0.00002744
27 Yes 12 0.00000001 0.00003954
28 Yes 12 0.00000001 0.00004116
29 Yes 12 0.00000001 0.00004330
30 Yes 12 0.00000001 0.00004537
31 Yes 12 0.00000001 0.00004779
32 Yes 12 0.00000001 0.00004836
33 Yes 12 0.00000001 0.00004727
34 Yes 12 0.00000001 0.00004762
35 Yes 12 0.00000001 0.00004774
36 Yes 12 0.00000001 0.00004597
37 Yes 12 0.00000001 0.00004444
38 Yes 12 0.00000001 0.00004223
39 Yes 12 0.00000001 0.00007432
40 Yes 12 0.00000001 0.00006555
41 Yes 12 0.00000001 0.00006875
42 Yes 12 0.00000001 0.00008495
43 Yes 12 0.00000001 0.00006972
44 Yes 12 0.00000001 0.00007115
45 Yes 12 0.00000001 0.00007589
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
11 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
46 Yes 12 0.00000001 0.00006861
47 Yes 12 0.00000001 0.00007180
48 Yes 12 0.00000001 0.00008636
49 Yes 12 0.00000001 0.00006994
50 Yes 12 0.00000001 0.00006681
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 120 - 67.0833 13.34 48 0.82 0.01
L2 71.25 - 31.6667 5.54 48 0.65 0.00
L3 36.5 - 0 1.60 48 0.39 0.00
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
120.00 1/2-in x 4-ft Lightning Rod 48 13.34 0.82 0.01 104440
118.00 HPD4-5.2 48 13.00 0.81 0.01 104440
60.00 PV-LPPGS-12M-HR2-AP19 48 4.03 0.58 0.00 7426
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 120 - 67.0833 73.47 20 4.52 0.04
L2 71.25 - 31.6667 30.52 20 3.61 0.02
L3 36.5 - 0 8.82 20 2.13 0.01
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
120.00 1/2-in x 4-ft Lightning Rod 20 73.47 4.52 0.04 19075
118.00 HPD4-5.2 20 71.61 4.49 0.04 19075
60.00 PV-LPPGS-12M-HR2-AP19 20 22.19 3.21 0.02 1353
Compression Checks
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
12 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Pole Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
L1 120 - 67.0833
(1)
TP26.08x16.51x0.22 52.92 0.00 0.0 17.71 -2.715 1035.760 0.003
L2 67.0833 -
31.6667 (2)
TP32.05x24.89x0.25 39.58 0.00 0.0 24.90 -10.305 1456.360 0.007
L3 31.6667 - 0 (3) TP37.28x30.68x0.28 36.50 0.00 0.0 33.47 -16.608 1958.240 0.008
Pole Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
L1 120 - 67.0833
(1)
TP26.08x16.51x0.22 174.61 589.43 0.296 0.00 589.43 0.000
L2 67.0833 -
31.6667 (2)
TP32.05x24.89x0.25 626.55 984.12 0.637 0.00 984.12 0.000
L3 31.6667 - 0 (3) TP37.28x30.68x0.28 1359.22 1530.95 0.888 0.00 1530.95 0.000
Pole Shear Design Data
Section
No.
Elevation
ft
Size
Actual
Vu
K
Vn
K
Ratio
Vu
Vn
Actual
Tu
kip-ft
Tn
kip-ft
Ratio
Tu
Tn
L1 120 - 67.0833
(1)
TP26.08x16.51x0.22 6.295 310.728 0.020 0.71 686.25 0.001
L2 67.0833 -
31.6667 (2)
TP32.05x24.89x0.25 17.619 436.908 0.040 3.39 1188.53 0.003
L3 31.6667 - 0 (3) TP37.28x30.68x0.28 22.367 587.473 0.038 3.39 1911.78 0.002
Pole Interaction Design Data
Section
No.
Elevation
ft
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Ratio
Vu
Vn
Ratio
Tu
Tn
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
L1 120 - 67.0833
(1)
0.003 0.296 0.000 0.020 0.001 0.299 1.000
L2 67.0833 -
31.6667 (2)
0.007 0.637 0.000 0.040 0.003 0.646 1.000
L3 31.6667 - 0 (3) 0.008 0.888 0.000 0.038 0.002 0.898 1.000
ttnnxxTToowweerr
Job
Sumter Wedgefield Road 230 Sub
Page
13 of 13
ETS, PLLC
3227 Wellington Court
Project
ETS, PLLC Job No.24131425.STR.3889
Date
20:59:39 07/11/25
Raleigh, NC 27615
Phone: (919) 782-2710
FAX:
Client
Duke Energy
Designed by
J. Scott Hilgoe, PE
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
L1 120 - 67.0833 Pole TP26.08x16.51x0.22 1 -2.715 1035.760 29.9 Pass
L2 67.0833 -
31.6667
Pole TP32.05x24.89x0.25 2 -10.305 1456.360 64.6 Pass
L3 31.6667 - 0 Pole TP37.28x30.68x0.28 3 -16.608 1958.240 89.8 Pass
Summary
Pole (L3) 89.8 Pass
RATING = 89.8 Pass
Program Version 8.3.1.2 - 12/11/2024 File:C:/Users/scott.hilgoe.ETS/OneDrive - Engineered Tower Solutions/Desktop/Working Folder/Duke/Sumter
Wedgefield/Analysis/Tower/Sumter Wedgefield.eri
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 7
tnxTower Report - version 8.3.1.2
APPENDIX B
POLE DESIGN SPECIFICATIONS
0'-0" REFERENCE LINE
307137B____,/
_,,,,-307137C
LSPLICE DIMENSION
MINIMUM= 38.47"
DESIGN = 50.00"
MAXIMUM= 56.00"
52' -11"
39' -7"
307137A_/
GROUND LINE
LSPLICE DIMENSION
MINIMUM= 47.32"
DESIGN = 58.00"
MAXIMUM= 64.00"
ELEVATION VIEW
SEE FABRICATION DRAWINGS FOR ADDITIONAL DETAILS
56' -6"
120' -0"
140' -0"
20' -0"
307137B~ ♦
1.00" NUT I 30.00"
(8 PLACES) ! t
12. 00"
♦ 7 t MIN SPLICE
MAX s:LICE t
[V
VALMONT ID TAG~
307137A
[
1/c__, 8. 00"
J t • 30.00"
]--~•
307137C~ ♦
1.00" NUT I 30.00"
(8 PLACES) ! t
12. 00"
~~• -~~7 t MIN SPLICE
MAX s:LICE t
[
VALMONT ID TAG_/
307137B
[
l)rc--' 8. 00"
NOTES:
1. COMPONENT IDENTIFICATION: VALMONT ID TAG
LOCATIONS ARE INDICATED BY CALLOUTS ON DRAWING. THE VALMONT ID TAG CONTAINS
INFORMATION FOR INTERNAL TRACKING AND FIELD
ASSEMBLY. ONLY THE VALMONT PART NUMBER NEEDS TO MATCH FDR FIELD ASSEMBLY, ALL OTHER
IDENTIFICATION IS FOR INTERNAL USE.
A= MANUFACTURING SITE (ONE CHARACTER) B = VALMONT PART NUMBER (SEVEN CHARACTERS)
C = FABRICATION SEQUENCE NUMBER (ONE OR MORE CHARACTERS)
D = VALMONT ORDER NUMBER (SIX CHARACTERS)
E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE CHARACTERS)
I
(A) (BBBBBBB) (C)
(DDDDDD) (E) I
2. ASSEMBLY AND ERECTION GUIDELINES: SEE VALMONT TRANSMISSION INSTALLATION GUIDELINE 1002
(WWW.VALMONTUTILITY.COM/I002).
REFER TO ELEVATION VIEW FOR MINIMUM AND
MAXIMUM SPLICE VALUES.
REFER TO ELEVATION VIEW FOR MINIMUM AND
MAXIMUM SPLICE VALUES. 3. SLIP JOINT JACKING FORCE MINIMUM= 25,000#
MAXIMUM= 90,000# SPLICE DETAIL
PROPRIETARY INFORMATION
THESE DOCUMENTS, DRAWINGS, AND/OR CALCULATIONS
AND ALL INFORMATION RELATED TD THEM ARE THE EXCLUSIVE PROPERTY ANO THE PROPRIETARY INFORMATION OF VALMONT INDUSTRIES, INC. ANO ARE
FURNISHED SOLELY UPON THE CONDITIONS THAT THEY
WILL BE RETAINED IN STRICTEST CONFIDENCE AND SHALL NOT BE DUPLICATED, USED, OR DISCLOSED IN WHOLE DR IN PART FOR ANY PURPOSE, IN ANY
WAY, WITHOUT THE PRIOR WRITTEN PERMISSION OF VALMONT INDUSTRIES, INC.
SPLICE DETAIL
VALMONT
PART NUMBER
BILL OF MATERIAL (SHIPPING SEQ. =1 FOR ALL)
DESCRIPTION
UNIT QTY
WEIGHT PER (LBS) STR
307137A SECTION ASSEMBLY 6,694 1
~ CLASS H10 307137B SECTION ASSEMBLY 3,130 1
iffi DEP. POLE ID·. 140-A 307137C SECTION ASSEMBLY 2,764 1
rD_U_P_L_IC_A_T_E_D_R_A_W_I_NG_D_I_S_TR_I_B_U_T_IO_N_,I PED487071140' H10 SIDED SW10 CS78231
I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 450
DRAWN I ENGR I DATE I SCALE
t---+----t---+--t--------------t AM70 BKB 1 01711?21 NONE
P.A. CHK I SHOP CHK
r---i-------t--r----t------------p.16"'-M7'--'o~oc=-1~; !.c11,,,,1~2~· i<~M""'s:c,4 ='0~1"';c=-1 '""'9;'-'2'4 valmont -OTHER SPECIFICATIONS V'
A O 1/19/21 AM7 KMS REVISED PER DRAFTING
ORDER ND· 1
487071
REV CHK
BY BY REVISION DESCRIPTION
CUSTOMER
DUKE
MATERIAL ITHICKNESSI WEIGHT
12,588#
I DESCRIPTION I DWG NO.
140' H10 SIDED SW10 CS78231 307137Z
1 .
2.
3.
LOCATION DIMENSION
FROM FROM
LARGE END SMALL
0'-
5'-
6'-
~ 30'-
26'- 0. 00"
24' - 0 . 00"
. - 22' - 0 . 00" .
- 20'- 0. 00"
~
0'- 7. 00"
0'- 0. 00"
~ - 0'- 0. 00"
FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD.
ALL CROSS SECTION VIEWS AND ORIENTATION
REFERENCES ARE FROM SMALL END OF THE TUBE.
ALIGN WITH FLATS AT SMALL END UNLESS
OTHERWISE NOTED.
END
7. 00"
4. 00"
0. 00"
2.38"
DETAIL
3-B
10
9-A
8
7
6
5-A
4
3-A
2
1
4
CUT OFF TAB AFTER
PLATE IS WELDED
TO SHAFT
2376375
046.00"
0. 188" THK
o " V •,J[[]J _______,~
4
[I]JJ
MARK ON BOTTOM OF
BEARING PLATE AN
APPROXIMATELY 03.00"
DOT WITH BLUE PAINT
OR MARKER
*AFTER GALVANIZING*
~D==E=T::::'.:A :::I L::::::::::1::::'.:::::'.:====:::::B::::E::::'.:A::::'.:R:::;I;::'.:N G;:::::'.:P::::".L".:'.::A=:'.;T::'.'.'.E====~ ~D::'.'.'.E::::'.:T::::'.:A :::I L:::::::::2".:'.::::::'.:=====::::'.:V A::::'.:L::'.:M:::::'.O::::'.:N::::'.:T=::::'.:M::::'.:A::::'.:R I<::'.::====~
DETAIL 5
1. 75"
TYP
- PART # THICKNESS
A 2612752 0 .250"
MIN~
T~TYP
i
BUB
DETAIL A
1. 75"
'
J 1.50" L
VIEW B-B
GROUND BRACKET
TYPE i FLAT (5) DIMENSION
A JACKING 4,10 30.00"
~------4------r i NUT
I DIMENSION
' SEE TABLE
rn-+--~ i NUT
345170
i FLAT
TYP O. 31
DETAIL 9 JACKING HANGING NUTS
MARK ON EXTERIOR OF THE
SHAFT AN APPROXIMATELY
03.00" DOT WITH BLUE
PAINT OR MARKER.
FLATS #6 & #12.
*AFTER GALVANIZING*
VIEW A-A
DETAIL 6 VALMONT MARK
NOTES:
SEAL
WELD
i OF TAG
(Al (BBBBBBB) - (Cl
(ODDDDD) - (E)
OF FLAT (S)
1
MAXIMUM
SLIP
STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE
REQUIRED INFORMATION SHOWN IN THIS DETAIL PER
WORK INSTRUCTION WI-11.02.
A MANUFACTURING SITE (ONE CHARACTER)
B VALMONT PART NUMBER (SEVEN CHARACTERS)
C FABRICATION SEQUENCE NUMBER (ONE OR MORE
CHARACTERS)
D VALMONT ORDER NUMBER (SIX CHARACTERS)
E VALMONT ORDER RELEASE NUMBER (ONE OR MORE
CHARACTERS)
DETAIL 10 VALMONT ID TAG
NOTES:
Rt. 06"
TYP
i FLAT
1n
........... --+--t-- 3. 00"
'
I
'
I
[, 13
1. NOTE FLAT ORIENTATION
- i FLAT (S)
A 4
B 4. 10
DETAIL 3 HANGING SLOT
I CHAR. HEIGHT I i OF FLAT (SI
I 0 . 50" I 4
i OF TAG
,,,.... I
'--1 SEE ID
TAG SHEET
PEC
FOR
REQUIRED
STAMPING
2131175_/ i
NOTE:
SEAL WELD AND VENT ID TAG PER M-91.
DETAIL 7 I CUSTOMER ID TAG
DUPLICATE DRAWING DISTRIBUTION
SEAM WELD
4
SEAL
TOP & >--~---hl
BOTTOM
GROUND
LINE
NOTE: VENT PER M-41
DETAIL 4
I
'
0
SEAM WELD
1'-0.00".
3'-0.00"
=r t
2756409
0 .250" THK
GROUND SLEEVE
OF FLAT (S)
1
2.00" LONG WELD
0.25" HIGH BEAD
i OF WELD BEAD AND FLAT
NOTE:
CENTER OF GRAVITY IS AN APPROXIMATE LOCATION .
THE CALCULATION DOES NOT ACCOUNT FOR WELD
MATERIAL OR MATERIAL SUBSTITUTIONS.
DETAIL 8 CENTER OF GRAVITY
BILL OF MATERIAL (SHIP SEQ=O)
VALMONT
PART ND DESCRIPTION
QTY
PER
ASSY
2756206 SHAFT
2376375 BEARING PLATE
2756409 GROUND SLEEVE 2
2612752 BRACKET 2
2131175 IDENTIFICATION TAG
345170 1.00" NUT 4
2070063 IDENTIFICATION TAG
TMF_SEC_ASSY_41"B0_31"TD __ 56'-6"LG _____ _
DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400
DRAWN ENGR DATE SCALE
t---+----+--+--+-------------1 AM70 BKB1 017TT""°;21 NONE
P.A. CHK SHOP CHK
M7ooT71112 MS401/19/2 valmont -OTHER SPECIFICATIONS V'
1--A-+0-1-/~1-9~/2-1-+A-M-7-+K-M-S+R-E_V_I_S_ED_P_E_R_D_RA_F_T_I_N_G----1 F-1 , M-1 , W-22
LOCATION SYMBOL KEY SHAFT INFO (MEASURED ACROSS FLATS) REV CHK REVISION DESCRIPTION
MATERIAL THICKNESS WEIGHT
6,694# ,,,.-. LOCATION
'7 REFERENCE
SHAPE LENGTH BASE OD TOP OD TAPER THK ASTM
12-SIDED 56'-6.00" 40.89" 30.67" 0.181 0.281" A572
ORDER ND.
487071
BY BY
CUSTOMER
DUKE
DESCRIPTION
SECTION ASSEMBLY
DWG NO.
307137A
1 .
2.
3.
LOCATION DIMENSION
FROM FROM LARGE END SMALL END DETAIL
------- 0'-7.00" 1-B
4' - 8.00" 6
5'- 4.00" 3-A
I I
20'- 7.38" 5
I
-1----1--1------------ 3 ' - 1 1 . 3 2 "
,- 3'- 6.00"
2'-0.00"
0-- --1--1'---------- 0 ' - 7 . 0 0 "
FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD.
ALL CROSS SECTION VIEWS AND ORIENTATION
REFERENCES ARE FROM SMALL END OF THE TUBE.
ALIGN WITH FLATS AT SMALL END UNLESS
OTHERWISE NOTED.
4
3-A
2
1-A
NOTES:
R1. 06"
TYP
i FLAT
1. NOTE FLAT ORIENTATION
1-1 i FLAT (S)
IAI 2
I BI 2. 8
MARK ON EXTERIOR OF THE~~ 2 1 12 SHAFT AN APPROXIMATELY I'--.
03. 00" DOT WITH BLUE "- ~
PAINT OR MARKER. ~~.--'-+---........,U
FLATS #6 S. #12.
*AFTER GALVANIZING*
VIEW A-A
~D==E=T::::'.:A :::I L::::::::::1::::'.:::::'.:=====::::::H A::::'.:N:::'.::G".::"I'.:=N:::::'.G=::::::S:;::L::::O T:'.:::====~ ~D::'.'.'.E:'.:::T::::'.:A :::I L:::::::::'.2'.:=::::'.:l=====:'.:::V A::::'.:L::::M::::::O::=N::::'.:T=::::'.:M:;::'.:A::::'.:R I<::'.::====~
I II OF FLAT (S) II OF FLAT (S)
I 1 1
NOTE:
I '
'
I
2.00" LONG WELD
0.25" HIGH
i OF WELD BEAD AND FLAT
BEAD
CENTER OF GRAVITY IS AN APPROXIMATE LOCATION.
THE CALCULATION DOES NOT ACCOUNT FOR WELD
MATERIAL OR MATERIAL SUBSTITUTIONS.
DETAIL 5 CENTER OF GRAVITY
,,...
'-/
NOTES:
i OF TAG
I
(A) (BBBBBBB) - (C)
(OODDDD) - (E)
MAXIMUM
SLIP
STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE
REQUIRED INFORMATION SHOWN IN THIS DETAIL PER
WORK INSTRUCTION WI-11.02.
A= MANUFACTURING SITE (ONE CHARACTER)
B = VALMONT PART NUMBER (SEVEN CHARACTERS)
C = FABRICATION SEQUENCE NUMBER (ONE OR MORE
CHARACTERS)
□ =VALMONT ORDER NUMBER (SIX CHARACTERS)
E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE
CHARACTERS)
DETAIL 6 I VALMONT ID TAG
- I TYPE I i FLAT (S) I DIMENSION
AIJACKINGI 4,10 I 30.00"
0----- ----4-----. i NUT
I DIMENSION
DRILL 0.50" DIA HOLE AT i FLAT #1.
' SEE TABLE
) f i NUT
345170
i FLAT
TYP; 0. 31 V ~
DETAIL 3 I JACKING/HANGING NUTS DETAIL 4 I MINIMUM SPLICE HOLE
BILL OF MATERIAL (SHIP SEQ=O)
VALMONT
PART NO DESCRIPTION
2756207 SHAFT
345170 1.00" NUT
QTY
PER
ASSY
8
2070063 IDENTIFICATION TAG l
DUPLICATE DRAWING DISTRIBUTION I TMF SEC ASSY 32"B0 25"TD 39' -7"LG
I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400
DRAWN I ENGR I DATE I SCALE
t--+----+--+---+------------1 AM70 BKB l O l 711"";21 NONE
P.A. CHK I SHOP CHK
r---i-------t--r----t-------------p.16"'-M7'--'o~oc=-1~;!.c11,,,,1~2~- i<~M""'s:c,4='0~1"';c=-1'""'9;'-'2'4valmont -OTHER SPECIFICATIONS V'
A O 1/19/21 AM7 KMS REVISED PER DRAFTING F-1,M-1,W-22
!LOCATION SYMBOL KEYi SHAFT INFO (MEASURED ACROSS FLATS) I REV CHK
BY BY REVISION DESCRIPTION MATERIAL THICKNESS! WEIGHT
3, 130#
I ,,,.-. LO CAT I ON I SHAPE I LENGTH I BASE OD I TOP OD IT APER I THK I ASTM I
'7 REFERENCE I 12-SIDED I 39' -7 .00"I 32.05" I 24.89" I 0.181 I 0.250" I A572 I ORDER ND -1
487071
CUSTOMER
DUKE I
DESCRIPTION
SECTION ASSEMBLY I DWG NO.
307137B
1 .
2.
3.
LOCATION DIMENSION
FROM FROM LARGE END SMALL END DETAIL
1::tt1i-~o---------~------~:===========O=' =-=0=·=0=0="===7=== - ~ _ O' - 6.00" 6
1'- 0.00" 5
---........____ 2'-0.00" 3-B
28'- 2.75" 4
3'-6.00" I ,,,-f-----+------+-------<
,______,,,.-, - 3'- 2.47"
3-A
O'- 7.00"
FLATS 1 AND 12 ARE ADJACENT TO SEAM WELD.
ALL CROSS SECTION VIEWS AND ORIENTATION
REFERENCES ARE FROM SMALL END OF THE TUBE.
ALIGN WITH FLATS AT LARGE END UNLESS
OTHERWISE NOTED.
2
1-A
NOTES:
R1. 06"
TYP
t FLAT
1. NOTE FLAT ORIENTATION
I- t FLAT (5)
IA 2
DRILL 0.50" DIA HOLE AT t FLAT #1.
~D==E=T::::::A:::IL::::::::::1::::'.:::::'.:=====::::::HA::::'.:N:::'.::G".::"I'.:=N:::::'.G=::::::S:=:L::::OT:'.:::====~ ~D::'.'.'.E:'.:::T::::'.:A'.".:'.IL:::::::::'.2'.:=::::'.:l==M::::'.:I::::N:::::'.I'.:=M:::::'.U::::'.:M=:::::S::::'.:PL'.'.'.:'.I'.'.::'.C'.;:'.'E'.:==H::::::O::=L:=:E=~
I G: OF FLAT (S)
MARK ON EXTERIOR OF THE------
SHAFT AN APPROX I MA TEL Y I"--~ 1 12
03. 00" DOT WITH BLUE ~
PAINT OR MARKER. ~-.-+--~~..,..,
FLATS #6 & #12.
*AFTER GALVANIZING*
VIEW A-A
DETAIL 5 VALMONT MARK
'-/
NOTES:
t OF TAG
I
(A) (BBBBBBB) - (C)
(DODDDD) - (E)
I 1
STAMP OR ENGRAVE IN 0.50" HIGH CHARACTERS THE
REQUIRED INFORMATION SHOWN IN THIS DETAIL PER
WORK INSTRUCTION WI-11.02.
A= MANUFACTURING SITE (ONE CHARACTER)
B = VALMONT PART NUMBER (SEVEN CHARACTERS)
C = FABRICATION SEQUENCE NUMBER (ONE OR MORE
CHARACTERS)
D = VALMONT ORDER NUMBER (SIX CHARACTERS)
E = VALMONT ORDER RELEASE NUMBER (ONE OR MORE
CHARACTERS)
DETAIL 6 I VALMONT ID TAG
- I TYPE I t FLAT (S) I DIMENSION
AIJACKINGI 4,10 I 30.00"
BIHANGINGI 2 I 8.00"
0----- ----4-----. t NUT
I DIMENSION
' SEE TABLE
) f t NUT
345170
t FLAT
TYP; 0. 31 V ~
DETAIL 3 I JACKING/HANGING NUTS
___.l._
A /"f"lll7' A
t FLATS 4 & 10 ---4---
t ti 11
NOTES:
1. TRIM STRAP AS NEEDED.
I t FLATS
l & 7
2. WELD STRAP 0.25" BELOW TOP.
3. INSTALL CAP PRIOR TO SHIPPING.
□ ET AIL 7 I POLE CAP STRAP
NOTE:
I '
'
I
I G: OF FLAT (5)
I 1
2.00" LONG WELD
0.25" HIGH BEAD
t OF WELD BEAD AND FLAT
CENTER OF GRAVITY IS AN APPROXIMATE LOCATION.
THE CALCULATION DOES NOT ACCOUNT FOR WELD
MATERIAL OR MATERIAL SUBSTITUTIONS.
DETAIL 4 I CENTER OF GRAVITY
BILL OF MATERIAL (SHIP SEQ=O)
VALMONT QTY
DESCRIPTION PER PART NO ASSY
2756208 SHAFT l
345170 1.00" NUT 6
2070063 IDENTIFICATION TAG l
1613173 POLE CAP MTG STRAP l
POST-FINISHING ATTACHMENTS
SEE DETAIL (SI 7 (SHIP SEQ=2)
163475H POLE CAP
1000422 0. 75"xl. OO"LG BOLT l
142056 0. 75" DIA FLATWSHR l
DUPLICATE DRAWING DISTRIBUTION I TMF SEC ASSY 26" BO 1 7 "TD 52' -11 "LG
I DWG SIZE Q CLASS CODE ( 1) 1. CLASS NO. (3) 400
DRAWN I ENGR I DATE I SCALE
t--+----+--+--+-------------1 AM70 BKB1 01711?21 NONE
P.A. CHK I SHOP CHK
r---i-------t--r----t------------p.16!.:!.M7'--'o~oc=-1~; !.c11,,,,1~2~· i<~M""'s:c,4 ='0~1"';c=-1 '""'9;'-'2'4 valmont -OTHER SPECIFICATIONS V'
A O 1/19/21 AM7 KMS REVISED PER DRAFTING F-1,M-1,W-22
!LOCATION SYMBOL KEYi SHAFT INFO (MEASURED ACROSS FLATS) I REV CHK
BY BY REVISION DESCRIPTION MATERIAL THICKNESS! WEIGHT
2,764#
I ,,,.-. LO CAT I ON I SHAPE I LENGTH I BASE OD I TOP OD IT APER I THK I ASTM I
'7 REFERENCE I 12-SIDED 152' -11.00"I 26.08" I 16.51" I 0.181 I 0.219" I A572 I ORDER ND· 1
487071
CUSTOMER
DUKE I
DESCRIPTION
SECTION ASSEMBLY I DWG NO.
307137C
Valmont taper per section: 0.181 in/ft
Overall taper: 0.174142857 in/ft
Section Length (ft) Elev (ft) Diameter (in) Thickness (in) Valmont Min. Lap Splice per
C 52.916667 120 16.51 0.219 Lap Splice TIA-222-H Sect. 4.9.7.1.
C 67.08333 26.08 0.219 50 in 38.463 in
B 39.583333 71.25 24.89 0.25
B 31.66667 32.05 0.25 58 in 47.325 in
A 56.5 36.5 30.67 0.281
A 0 37.2765 0.281 Pole AVG Embed. Diam. 39.08325 in
A -20 40.89 0.281 Pole AVG Embed. Diam. 3.256938 ft
Per TIA-222-H-1 Section 9.4.3.1:
For gravel backfill, it shall be permissible to consider a constant
effective foundation diameter over the embedment depth equal
to the average of the mid-depth diameter of the pole and the outer *Drill Bit Diam. for Embed. 4.5 ft
diameter of the gravel annulus, not to exceed the pole base Thus, the effective Fdn Diam. 3.878469 ft
diameter plus 9 in. [229 mm].
*Note: East Construction uses the pole bottom diameter + 6in of gravel on each side to select their drill bit diameter.
Example: 40.89+6+6=52.89 inch However, drill bits only come in half foot sizes so a 54" bit would be used in this example.
07/11/2025
140-ft Valmont H10 (Direct Bury 120-ft AGL) Ft Monopole Structural Analysis Report Site Name: Sumter Wedgefield Road 230 Sub
Job Number: 24131425.STR.3889 Page 8
tnxTower Report - version 8.3.1.2
APPENDIX C
ADDITIONAL CALCULATIONS
AV
Report File:
TIA-222 Revison:
Tower Type: Check Pier Capacity only at location of Max Moment? No
Location:
Soil Lateral Check Compression Uplift
Comp. Uplift 4.31 -
1359 1.31 -
17 1422.41 -
22 101.9% -
Soil Vertical Check Compression Uplift
84.07 -
3 ksi 145.33 -
60 ksi . 9.21 -
40 ksi 229.40 -
26.21 -
11.4% -
20 ft Embedded Pole Interaction Compression Uplift
0 ft 3.28 -
1417.38 -
1565.91 -
3.878469 ft 91.4% -
27 Reinforced Concrete Shear Compression Uplift
- -
3 in - -
4 - -
in - -
in
6 # of Layers 6
121
FALSE 1 0 4 4 100 150 0 27 0.000 0.000 0.00 0.00
FALSE 2 4 6 2 105 150 0 27 0.000 0.000 0.20 0.00
FALSE 3 6 8 2 42.6 87.6 0 29 0.000 0.000 0.30 0.30
FALSE 4 8 12 4 57.6 87.6 0 30 0.000 0.000 0.50 0.50
FALSE 5 12 17 5 57.6 87.6 0 30 0.000 0.000 0.70 0.70
FALSE 6 17 20 3 62.6 87.6 0 30 0.000 0.000 0.90 0.90 15
Pier Diameter
Rebar Quantity
Rebar Cage Diameter
Rebar Quantity
Tie Spacing
Embedded Pole Foundation
Site Name:
Monopole
Applied Loads
Material Properties
Pier Design Data
H
Sumter Wedgefield
Moment (kip-ft)
Axial Force (kips)
Shear Force (kips)
Concrete Strength, f'c:
Rebar Strength, Fy:
Tie Yield Strength, Fyt:
Cohesionless
Cohesionless
Cohesionless
Cohesionless
Cohesionless
Ultimate Skin
Friction Uplift
Override (ksf)
Critical Shear Capacity
Rating
Skin Friction (kips)
Weight of Concrete (kips)
Rating
Critical Shear (kip)
End Bearing (kips)
Axial (kips)
Critical Depth (ft from TOC)
Calculated
Ultimate Skin
Friction Uplift
(ksf)
Calculated
Ultimate Skin
Friction Comp
(ksf)
Ultimate Skin
Friction Comp
Override
(ksf)
Soil Profile
Soil TypeSPT Blow
Count
Ult. Net
Bearing
Capacity
(ksf)
γsoil
(pcf)
γconcrete
(pcf)
Critical Depth (ft from TOC)
101.9%Soil Interaction Rating
Rebar 2, Fy
Override
(ksi)
Rebar 3, Fy
Override
(ksi)
Depth
Cohesionless
Layer Top
(ft) Bottom (ft) Thickness
(ft)
Groundwater Depth
Cohesion
(ksf)
Angle of
Friction
(degrees)
Rebar Size
Pier Section 1
Dv=0 (ft from TOC)
Soil Safety Factor
Max Moment (kip-ft)
Rating
Ext. Above Grade
Critical Moment (kip-ft)
Critical Moment Capacity
Rating
From 0' below grade to 20' below grade
Rebar Size
Clear Cover to Ties
Tie Size
D:\ETS\SE PROJECTS\2024\07 JUL\Frankfort 230 (INFRA2)_24125456.STR.7253 r Analysis\Analysis\Tower\Frankfort 230 (INFRA2).eri.rtf
91.4%Structural Foundation Rating
Total Capacity (kips)
Analysis Results
Rebar & Pier Options
Embedded Pole Inputs
Belled Pier Inputs
Version 5.0.3
Site Name: Sumter Wedgefield
Encased in Concrete: No
Number of Sides: 12
Yield Strength (ksi): 65
Thickness (in): 0.281
Bend Radius (in): 0.4215
Taper Factor (in/ft): 0.1809
Depth from Grade (ft): 6.01
Diameter (in): 38.36
Axial Demand (kip): 19.87
Axial Capacity (kip): 2055.10
Rating: 1.0%
Depth from Grade (ft): 3.23
Diameter (in): 37.86
Flexural Demand (kip-ft): 1416.91
Flexural Capacity (kip-ft): 1565.38
Rating: 90.5%
Depth from Grade (ft): 3.28
Diameter (in): 37.8656
Axial Demand (kip): 18.84
Axial Capacity (kip): 2044.17
Flexural Demand (kip-ft): 1417.38
Flexural Capacity (kip-ft): 1565.91
Version Rating: 91.4% Structural Rating: 91.4%
Version 5.0.3
Maximum Interaction Rating
Maximum Flexural Rating
Maximum Axial Rating
SUPPLEMENTAL EMBEDDED POLE REPORT
Embedded Pole Properties
ASCE Hazards Report
Address:
No Address at This Location
Standard: ASCE/SEI 7-16 Latitude: 33.912755
Risk Category: III Longitude: -80.393316
Soil Class: D - Default (see
Section 11.4.3)
Elevation: 183.87499719305484 ft
(NAVD 88)
Wind
Results:
Wind Speed 133 Vmph
10-year MRI 75 Vmph
25-year MRI 84 Vmph
50-year MRI 92 Vmph
100-year MRI 99 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1C and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Fri Jul 11 2025
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 3% probability of exceedance in 50 years (annual exceedance probability =
0.000588, MRI = 1,700 years).
Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings need not be
protected against wind-borne debris.
Page 1 of 3https://ascehazardtool.org/ Fri Jul 11 2025
SS : 0.384
S1 : 0.128
F a : 1.493
F v : 2.343
SMS : 0.573
SM1 : 0.301
SDS : 0.382
SD1 : 0.201
T L : 8
PGA : 0.219
PGA M : 0.302
F PGA : 1.381
Ie : 1.25
Cv : 0.956
Seismic Design Category: D Design Response Spectrum
S (g) vs T(s)a
MCE Response SpectrumR
S (g) vs T(s)a
Design Vertical Response Spectrum
S (g) vs T(s)a
MCE Vertical Response SpectrumR
S (g) vs T(s)a
Seismic
D - Default (see Section 11.4.3)Site Soil Class:
Results:
Data Accessed: Fri Jul 11 2025
Date Source:
USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for
site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS.
Page 2 of 3https://ascehazardtool.org/ Fri Jul 11 2025
Ice
Results:
Data Source:
Date Accessed:
Ice Thickness: 1.00 in.
Concurrent Temperature: 15 F
Gust Speed 30 mph
Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8
Fri Jul 11 2025
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any
kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or
has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable
sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or
quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,
relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE Hazard Tool.
Page 3 of 3https://ascehazardtool.org/ Fri Jul 11 2025
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
TITLE PAGE
T-1
SITE
N
NW
W
SW
S
SE
E
NE
NNW
WNW
WSW
SSWSSE
ESE
ENE
NNE
GENERAL NOTES
THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, THEREFORE HANDICAP ACCESS IS
NOT REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT
DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR
TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED.
SCOPE OF WORK
INSTALLATION OF A PROPOSED 120'± MONOPOLE, WITH NEW MOUNTED CAMBIUM 5GHz EQUIPMENT,
WITHIN AN EXISTING DUKE ENERGY OWNED ELECTRICAL SUBSTATION.
CODE COMPLIANCE
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE
CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING
AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT
CONFORMING TO THE FOLLOWING CODES:
SITE MAPSITE PHOTO
·2021 S.C. BUILDING CODE (2021 IBC W/ AMENDMENTS)
·2021 S.C. EXISTING BUILDING CODE (2021 IEBC W/ AMENDMENTS)
·2021 S.C. FIRE CODE (2021 IFC W/ AMENDMENTS)
·2021 S.C. FUEL GAS CODE (2021 IFGC W/ AMENDMENTS)
·2021 S.C. MECHANICAL CODE (2021 IMC W/ AMENDMENTS)
·2021 S.C. PLUMBING CODE (2021 IPC W/ AMENDMENTS)
·2020 S.C. ELECTRICAL CODE (2020 NEC W/ AMENDMENTS)
·2021 S.C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
SUBSTATION NAME:
SUMTER WEDGEFIELD ROAD 230 SUB
SUBSTATION TELECOM NUMBER:
SCSMT017
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
LATITUDE & LONGITUDE:
N 33° 54' 45.90" , W 80° 23' 35.90"
SUBSTATION TRANSMISSION NUMBER:
T3985
PROJECT TEAM
SURVEYOR
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
JMT.
2154 N. CENTER STREET SUITE A-101
NORTH CHARLESTON, SC 29406
RANDALL L. STEPP
(843) 974-5650
CIVIL ENGINEER
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
ENGINEERED TOWER SOLUTIONS
3227 WELLINGTON COURT
RALEIGH, NC 27615
CHRISTOPHER G. PLY, P.E., S.E.
(919) 782-2710
STRUCTURAL ENGINEER
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
ENGINEERED TOWER SOLUTIONS
3227 WELLINGTON COURT
RALEIGH, NC 27615
CHRISTOPHER G. PLY, P.E., S.E.
(919) 782-2710
ELECTRICAL ENGINEER
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
ENGINEERED TOWER SOLUTIONS
3227 WELLINGTON COURT
RALEIGH, NC 27615
CHRISTOPHER G. PLY, P.E., S.E.
(919) 782-2710
GEOTECHNICAL ENGINEER
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
ENGINEERED TOWER SOLUTIONS
3227 WELLINGTON COURT
RALEIGH, NC 27615
FREDERIC G. BOST, P.E.
(919) 782-2710
POLE MANUFACTURER
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
VALMONT INDUSTRIES
15000 VALMONT PLAZA
OHAHA, NEBRASKA, 98154
CUSTOMER SERVICE
1(402) 963-1000
SITE SUMMARY
SITE TYPE:NEW CONSTRUCTION
STRUCTURE TYPE:MONOPOLE
STRUCTURE OWNER:DUKE ENERGY
SITE APPLICANT:DUKE ENERGY
STRUCTURE HEIGHT (AGL):120'±
OCCUPANCY TYPE:UTILITY & MISCELLANEOUS (U)
STRUCTURE LATITUDE (NAD 83):N 33° 54' 45.90" (33.912755°)
STRUCTURE LONGITUDE (NAD 83):W 80° 23' 35.90" (-80.393316°)
PROPERTY OWNER:DUKE ENERGY
JURISDICTION:CITY OF SUMTER
COUNTY:SUMTER
PARCEL ID:2060002010
GROUND ELEV. (NAVD):183.7'
INDEX OF SHEETS
T-1TITLE PAGE
1 OF 1SURVEY
GN-1GENERAL NOTES I
GN-2GENERAL NOTES II
GN-3GENERAL NOTES III
C-1.0OVERALL PROPERTY PLAN
C-1.1SUBSTATION COMPOUND PLAN
C-1.2TRANSMISSION GROUNDING PLAN
C-1.3TRANSMISSION CONDUIT PLAN
C-2COMMUNICATION POLE ELEVATION & ANTENNA PLAN
C-3.1 DETAILS I
C-3.2 DETAILS II
C-3.3 DETAILS III
C-3.4 DETAILS IV
SITE
SITE
2154 N. CENTER STREET
SUITE A-101
NORTH CHARLESTON, SC 29406
843-974-5650
P: (843) 556-2624 | www.jmt.com
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
GENERAL NOTES I
GN-1
1. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND CARRIER
PROJECT SPECIFICATIONS.
2. GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL
CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT
DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND SHALL CONFIRM THAT THE WORK MAY BE
ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF
WORK.
3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL
APPLICABLE CODES, REGULATIONS AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE
ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS,
AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK.
4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY
COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE
REGULATIONS.
5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT,
APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED IN
THESE DRAWINGS.
6. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE
ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISHED SURFACES UNLESS
OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE.
THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS
REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT
JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF
WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK.
7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.
8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN IN THESE DRAWINGS, THE
CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE
ENGINEER PRIOR TO PROCEEDING.
9. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT
AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER
THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL
JURISDICTION.
10.GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH
OTHER DISCIPLINES.
11.ERECTION SHALL BE DONE IN WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMEN
IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS
SHALL BE LAID PLUMB AND TRUE AS INDICATED IN THE DRAWINGS.
12.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY
LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF
ALL DEBRIS.
13.THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND
NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING
CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION.
14.CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS
PRIOR TO THE COMMENCEMENT OF WORK.
15.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS,
LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S
EXPENSE TO THE SATISFACTION OF THE OWNER.
16.THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF
CONSTRUCTION.
17. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND
CONTRACTORS TO THE SITE AND/OR BUILDING.
18.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE
DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.
19.THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF
PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES.
20.THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING
OF NO LESS THAN 2-A OR 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL
PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION.
21. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE
PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF
THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME
CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING
PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING
FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL
PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING &
EXCAVATION.
22. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH
INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED,
PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE
WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER,
AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES.
23. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT
COVERED BY THE COMMUNICATION POLE, EQUIPMENT OR DRIVEWAY, SHALL BE
GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION.
24. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING
CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING
CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL
JURISDICTION FOR EROSION AND SEDIMENT CONTROL.
25. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING.
FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR
EMBANKMENT.
26. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED
TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES
AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN
PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER
MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION.
27. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE
SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER.
28. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP
DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL
CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT.
29. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE
GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL
PAYMENT.
30. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION.
31. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE
WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS
REQUIRED).
32. STRUCTURE IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION,
APPROXIMATELY 2 TIMES PER MONTH, BY CARRIER TECHNICIANS.
33. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED.
34. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST CARRIER GROUNDING STANDARD. IN CASE OF A
CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE
DRAWINGS SHALL GOVERN.
35. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A
PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY.
36. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY
BASIS.
37. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS
AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY
THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR
PROCEEDING WITH CONSTRUCTION.
38. ALL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS.
39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA
STANDARDS AND REQUIREMENTS.
1. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE
WITH ASTM A123 "ZINC (HOT-DIP GALVANIZED) COATINGS ON IRON AND STEEL
PRODUCTS", UNLESS NOTED OTHERWISE.
2. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN
ACCORDANCE WITH ASTM A153 "ZINC-COATING (HOT-DIP) ON IRON AND STEEL
HARDWARE", UNLESS NOTED OTHERWISE.
3. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN
ACCORDANCE WITH ASTM A780.
4. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND
SHALL BE TORQUED TO MANUFACTURER'S RECOMMENDATIONS.
5. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR
INSTALLATION AND GROUNDING.
6. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR
SHALL CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE
PLUMB. ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH AND BE ORIENTED
WITHIN +/- 5% AS DEFINED BY THE RFDS. ANTENNA DOWNTILTS SHALL BE WITHIN +/-
0.5% AS DEFINED BY THE RFDS. REFER TO ND-00246.
7. CONTRACTOR SHALL VERIFY THE DOWN-TILT OF EACH ANTENNA WITH A DIGITAL LEVEL.
1. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH.
2. ALL RF CONNECTIONS, GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE
A TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF
THE CONNECTION.
3. RF CONNECTION BOTH SIDES OF THE CONNECTOR.
4. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE
THREADS TO THE SOLID SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR,
ANTENNA BRACKET METAL.
5. ALL 2', 3' & 4' ANTENNA HARDWARE SHALL BE TIGHTENED TO 9 LB-FT (12 NM).
6. ALL 6' ANTENNA HARDWARE SHALL BE TIGHTENED TO 43 LB-FT (58 NM).
7. ALL GROUNDING HARDWARE SHALL BE TIGHTENED UNTIL THE LOCK WASHER
COLLAPSES AND THE GROUNDING HARDWARE IS NO LONGER LOOSE.
8. ALL DIN TYPE CONNECTIONS SHALL BE TIGHTENED TO 18-22 LB-FT (24.4-29.8 NM).
9. ALL N TYPE CONNECTIONS SHALL BE TIGHTENED TO 15-20 LB-IN (1.7-2.3 NM).
GENERAL NOTESGENERAL NOTES (CONTINUED)ANTENNA MOUNTING NOTES
TORQUE REQUIREMENTS
1. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO
ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION
LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED
LENGTHS.
2. CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. REFER TO
"ANTENNA SYSTEM LABELING STANDARD" ND-00027 LATEST VERSION.
3. ALL JUMPERS TO THE ANTENNAS SHALL BE 1/2" DIA. LMR 400 AND SHALL NOT EXCEED 3'-0".
4. ALL COAXIAL CABLE SHALL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE, IN AN
APPROVED MANNER, AT DISTANCES NOT TO EXCEED 4'-0" OC.
5. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH
THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND
ALL OTHER EQUIPMENT.
6. CONTRACTOR SHALL WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF
AMALGAMATING TAPE. WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE
WITH INDUSTRY STANDARDS.
COAXIAL CABLE NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX
CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION.
2. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
3. CONTRACTOR SHALL REFERENCE THE STRUCTURAL ANALYSIS/DESIGN DRAWINGS FOR
DIRECTIONS ON CABLE DISTRIBUTION/ROUTING.
GENERAL CABLE AND EQUIPMENT NOTES
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
GENERAL NOTES II
GN-2
1. ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED, EXCEPT THE
RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE
MADE. BUTYL TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH
TURN AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE
SMOOTH WITHOUT BUCKLING. BUTYL BLEEDING IS NOT ALLOWED.
2. IF REQUIRED TO PAINT ANTENNAS AND/OR COAX:
2.1. TEMPERATURE SHALL BE ABOVE 50° F.
2.2. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD.
2.3. FOR REGULATED TOWERS, FAA/FCC APPROVED PAINT IS REQUIRED.
2.4. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS.
3. ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING
ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR.
TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION.
4. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER
MANUFACTURER'S SPECIFICATION & RECOMMENDATIONS.NO BOLT THREADS TO PROTRUDE
MORE THAN 1-1/2" [.038M].
5. 90 SHORT SWEEPS UNDER ANTENNA ARM. ALL CABLES MUST ONLY TRANSITION ON THE INSIDE
OR BOTTOM OF ARMS (NO CABLE ON TOP OF ARMS).
6. USE 90 CONNECTOR AT CABLE CONNECTION TO ANTENNAS.
7. PLACE GPS ON ARM WITH SOUTHERN SKY EXPOSURE AT MINIMUM 6' [1.83] FROM TRANSMIT
ANTENNA, WHICH IS 24" [.61M] AWAY FROM CENTER OF POLE.
8. USE 1/2" [.013M] CABLE ON ANTENNAS UNLESS OTHERWISE SPECIFIED.
9. FILL VOID AROUND CABLES AT CONDUIT OPENING WITH FOAM SEALANT TO PREVENT WATER
INTRUSION.
GENERAL CABLE AND EQUIPMENT NOTES
FIBER & POWER CABLE MOUNTING
FOUNDATION GENERAL NOTES
1. ALL WELDING SHALL BE IN ACCORDANCE WITH THE AWS D1.1/D1.1M: 2015 "STRUCTURAL
WELDING CODE-STEEL".
2. ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS.
3. CONTRACTOR SHALL RETAIN AN AWS CERTIFIED WELD INSPECTOR TO PERFORM VISUAL
INSPECTIONS ON FIELD WELDS. A LETTER AND REPORT SHALL BE ISSUED TO THE
CONTRACTOR. CONTRACTOR SHALL SUBMIT LETTER AND REPORT TO TOWER OWNER.
4. GRIND THE SURFACE ADJACENT TO THE WELD FOR A DISTANCE OF 2" MINIMUM ALL AROUND.
GRIND THE SURFACE OF THE ROD TO BE INSTALLED FOR A DISTANCE OF 2" MINIMUM ALL
AROUND THE AREA TO BE WELDED. ENSURE BOTH AREAS ARE 100% FREE OF ALL
GALVANIZING. SURFACES TO BE WELDED SHALL BE FREE FROM SCALE, SLAG, RUST,
MOISTURE, GREASE OR ANY OTHER FOREIGN MATERIAL THAT WOULD PREVENT PROPER
WELDING.
5. DO NOT WELD IF THE TEMPERATURE OF THE STEEL IN THE VICINITY OF THE WELD AREA IS
BELOW 0°F. WHEN THE TEMPERATURE IS BETWEEN 0°F AND 32°F, PREHEAT AND MAINTAIN THE
STEEL IN THE VICINITY OF THE WELD AREA AT 70°F DURING THE WELDING PROCESS.
6. DO NOT WELD ON WET OR FROST-COVERED SURFACES & PROVIDE ADEQUATE PROTECTION
FROM HIGH WINDS.
7. FOR ALL WELDING, USE E70XX ELECTRODES.
8. AFTER FINAL INSPECTION, THE AREA OF THE WELDS, THE INSTALLATION AND ALL SURFACES
DAMAGED BY WELDING OR GRINDING SHALL RECEIVE A COLD-GALVANIZED COATING. THIS
COATING SHALL BE APPLIED BY BRUSH. THE GALVANIZING COMPOUND SHALL CONTAIN A
MINIMUM OF 95% ± PURE ZINC. THE FINISHED COATING SHALL BE A MINIMUM THICKNESS OF 3
MILS.
FOUNDATION NOTES
BOLT TIGHTENING PROCEDURE
WELDING NOTES
STRUCTURAL STEEL NOTES
FOUNDATION NOTES (CONTINUED)
1. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE AISC
SPECIFICATION FOR MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR
DESIGN, 15TH EDITION.
2. UNLESS OTHERWISE NOTED, ALL STRUCTURAL ELEMENTS SHALL CONFORM TO THE
FOLLOWING REQUIREMENTS:
STRUCTURAL STEEL:
·ANGLE: ASTM A36
·PIPE/TUBE: ASTM A500-50
·PLATE: ASTM A36
A. ALL BOLTS, ASTM A325 TYPE I GALVANIZED HIGH STRENGTH BOLTS.
B. ALL U-BOLTS, ASTM A193 GRADE B7
C. ALL NUTS, ASTM A563 CARBON AND ALLOY STEEL NUTS.
D. ALL WASHERS, ASTM F436 HARDENED STEEL WASHERS.
3. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL
FABRICATOR IN ACCORDANCE WITH AISC SPECIFICATION FOR MANUAL OF STEEL
CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN, 15TH EDITION.
4. HOLES SHALL NOT BE FLAME CUT THRU STEEL UNLESS APPROVED BY THE ENGINEER.
5. HOT-DIP GALVANIZE ALL ITEMS UNLESS OTHERWISE NOTED, AFTER FABRICATION WHERE
PRACTICABLE. GALVANIZING: ASTM A123, ASTM, A153/A153M OR ASTM A653/A653M, G90, AS
APPLICABLE.
6. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING
TO ASTM A780 OR BY APPLICATION OF STICK OR THICK PASTED MATERIAL SPECIFICALLY
DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED AND REMOVE SLAG
FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED, WITH A
TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS IN STICK OR PASTED;
SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF
EXCESS MATERIAL.
7. A NUT LOCKING DEVICE SHALL BE INSTALLED ON ALL PROPOSED AND/OR REPLACED BOLTS.
8. ALL PROPOSED AND/OR REPLACED BOLTS SHALL BE OF SUFFICIENT LENGTH TO EXCLUDE THE
THREADS FROM THE SHEAR PLANE.
9. ALL PROPOSED AND/OR REPLACED BOLTS SHALL BE OF SUFFICIENT LENGTH SUCH THAT THE
END OF THE BOLT BE AT LEAST FLUSH WITH THE FACE OF THE NUT. IT IS NOT PERMITTED FOR
THE BOLT END TO BE BELOW THE FACE OF THE NUT AFTER TIGHTENING IS COMPLETED.
10. GALVANIZED ASTM A325 BOLTS SHALL NOT BE REUSED.
1. CONNECTION BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED AND TIGHTENED AS
PER SECTION 8.2 OF THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490
BOLTS, LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. THE INSTALLATION
PROCEDURE IS PARAPHRASED AS FOLLOWS:
2. FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONE OF
THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4.
8.2.1 TURN-OF-THE-NUT TIGHTENING. BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE
CONNECTION AND BROUGHT TO A SNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL
ALL THE BOLTS ARE SIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY
COMPACTED. FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BE
TIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE. DURING
THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOT TURNED BY
THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART
OF THE JOINT IN A MANNER THAT WILL MINIMIZE RELAXATION OF PREVIOUSLY PRETENSIONED
BOLTS.
3. TIGHTEN CONNECTION BOLTS BY AISC - "TURN OF THE NUT" METHOD, USING THE CHART
BELOW.
BOLT LENGTHS UP TO AND INCLUDING FOUR DIA.
12" BOLTS UP TO AND INCLUDING 2.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT
58" BOLTS UP TO AND INCLUDING 2.5 INCH LENGTH +13 TURN BEYOND SNUG TIGHT
34" BOLTS UP TO AND INCLUDING 3.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT
78" BOLTS UP TO AND INCLUDING 3.5 INCH LENGTH +13 TURN BEYOND SNUG TIGHT
1" BOLTS UP TO AND INCLUDING 4.0 INCH LENGTH +13 TURN BEYOND SNUG TIGHT
BOLT LENGTHS OVER FOUR DIA. BUT NOT EXCEEDING EIGHT DIA.
12" BOLTS 2.25 TO 4.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT
58" BOLTS 2.75 TO 5.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT
34" BOLTS 3.25 TO 6.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT
78" BOLTS 3.75 TO 7.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT
1" BOLTS 4.25 TO 8.0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT
4. ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS
DEFINED IN SECTION 8.1 OF THE SPECIFICATION.
1. FOUNDATION INSTALLATION SHALL BE SUPERVISED BY PERSONNEL KNOWLEDGEABLE AND
EXPERIENCED WITH THE PROPOSED FOUNDATION TYPE. CONSTRUCTION SHALL BE IN
ACCORDANCE WITH GENERALLY ACCEPTED PRACTICES AND IN A GOOD WORKMANLIKE
MANNER.
2. CONTRACTOR TO VERIFY DIMENSIONS WITH ORIGINAL TOWER DRAWINGS. ETS SHALL BE
NOTIFIED OF ANY DISCREPANCIES BETWEEN FIELD MEASURED DIMENSIONS AND ORIGINAL
TOWER DRAWINGS.
3. FOUNDATION DESIGN MODIFICATIONS MAY BE REQUIRED IN THE EVENT THE DESIGN
PARAMETERS ARE NOT APPLICABLE FOR THE SUBSURFACE CONDITIONS ENCOUNTERED
DURING CONSTRUCTION.
4. FOR FOUNDATION TOLERANCES, SEE ORIGINAL TOWER DRAWINGS.
5. THE FOUNDATION MODIFICATION DESIGN IS IN ACCORDANCE WITH GENERALLY ACCEPTED
PROFESSIONAL ENGINEERING PRINCIPLES AND PRACTICES WITHIN THE LIMITS OF
SUBSURFACE DATA PROVIDED.
6. THE FOUNDATION DEPTH INDICATED IS BASED ON THE GRADE LINE DESCRIBED IN THE
REFERENCE GEOTECHNICAL REPORT. FOUNDATION MODIFICATION MAY BE REQUIRED IN THE
EVENT CUT OR FILL OPERATIONS HAVE TAKEN PLACE SUBSEQUENT TO THE GEOTECHNICAL
INVESTIGATION.
7. THE FOUNDATION DESIGN ASSUMES THAT INSTALLATION METHODS WILL INCORPORATE THE
PROCEDURES RECOMMENDED IN THIS REPORT.
8. THE FOUNDATION DESIGN ASSUMES FIELD INSPECTIONS WILL BE PERFORMED TO VERIFY
THAT CONSTRUCTION MATERIALS, INSTALLATION METHODS, AND ASSUMED DESIGN
PARAMETERS ARE ACCEPTABLE BASED ON THE CONDITIONS AT THE SITE.
9. THE FOUNDATION DESIGN ASSUMES NO CONSTRUCTION JOINTS, HOWEVER, CONSTRUCTION
JOINTS SHALL BE PERMITTED UPON APPROVAL BY THE OWNER/ENGINEER.
EXCAVATION
1. WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND SAFETY REGULATIONS.
PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION, AND
UTILITIES SHALL BE ESTABLISHED PRIOR TO BEGINNING WORK.
2. THE SIDES OF THE EXCAVATION SHALL BE ROUGH AND FREE OF CUTTINGS.
3. LOOSE MATERIAL TO BE REMOVED FROM THE BOTTOM OF EXCAVATION PRIOR TO CONCRETE
PLACEMENT.
REINFORCING STEEL
1. THE REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615, GRADE 60.
IT SHALL BE DEFORMED AND SPLICES SHALL NOT BE ALLOWED UNLESS OTHERWISE NOTED.
2. WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENTS.
3. REINFORCING CAGES SHALL BE BRACED TO RETAIN PROPER DIMENSIONS DURING HANDLING
AND THROUGHOUT PLACEMENT OF CONCRETE. WHEN TEMPORARY CASING IS UTILIZED,
BRACING SHALL BE ADEQUATE TO RESIST FORCES OCCURRING FROM FLOWING CONCRETE
DURING CASING EXCAVATION.
4. SPACERS SHALL BE ATTACHED INTERMITTENTLY THROUGHOUT THE ENTIRE LENGTH OF
TIEBACK REINFORCING TO INSURE CONCENTRIC PLACEMENT OF CASING IN EXCAVATIONS.
5. MINIMUM CONCRETE COVER FOR REINFORCEMENT SHALL BE 3" UNLESS OTHERWISE NOTED.
APPROVED SPACERS SHALL BE USED TO INSURE A 3" MINIMUM COVER FOR REINFORCEMENT.
6. THE CONCRETE COVER FROM THE TOP OF THE FOUNDATION TO THE ENDS OF THE VERTICAL
REINFORCEMENT SHALL NOT BE LESS THAN 3".
CONCRETE
1. WORK SHALL BE IN ACCORDANCE WITH THE ACI 318-14, "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE AND COMMENTARY".
2. THE CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 3000-PSI IN 28 DAYS.
3. ANY CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED AS REQUIRED BY ACI 318-14.
4. PROPORTIONS OF CONCRETE MATERIALS SHALL BE SUITABLE FOR THE INSTALLATION
METHOD UTILIZED AND SHALL RESULT IN DURABLE CONCRETE FOR RESISTANCE TO LOCAL
ANTICIPATED AGGRESSIVE ACTIONS. THE DURABILITY REQUIREMENTS OF ACI 318-14 SHALL BE
SATISFIED BASED ON THE CONDITIONS EXPECTED AT THE SITE.
5. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE
MATERIALS, INFILTRATION OF WATER OR SOIL, AND OTHER OCCURRENCES THAT MAY
DECREASE THE STRENGTH OR DURABILITY OF THE FOUNDATION.
6. FREE FALL CONCRETE MAY BE USED PROVIDED FALL IS VERTICAL DOWN WITHOUT HITTING
THE SIDES OF THE EXCAVATION, FORMWORK, REINFORCING BARS, FORM TIES, CAGE BRACING,
OR OTHER OBSTRUCTIONS. UNDER NO CIRCUMSTANCES SHALL CONCRETE FALL THROUGH
WATER.
7. THE MAXIMUM SIZE OF THE AGGREGATE SHALL NOT EXCEED A SIZE SUITABLE FOR THE
INSTALLATION METHODS UTILIZED OR 2/3-CLEAR DISTANCE BEHIND OR BETWEEN
REINFORCING. THE MAXIMUM SIZE MAY BE INCREASED TO 2/3-CLEAR DISTANCE PROVIDED
WORKABILITY AND METHODS OF CONSOLIDATION SUCH AS VIBRATING WILL PREVENT
HONEYCOMBS AND VOIDS.
FINISHING
1. THE TOP OF THE FOUNDATION SHALL BE SLOPED TO DRAIN WITH A FLOATED FINISH.
2. THE EXPOSED EDGES OF THE CONCRETE SHALL BE CHAMFERED 1" X 1".
EPOXY NOTES
1. EPOXY AGENTS SHOULD BE ALLOWED TO CURE ACCORDING TO MANUFACTURERS
RECOMMENDATIONS.
2. ALL HARDWARE ASSEMBLY AND MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED; ANY
CONTRADICTION BETWEEN THE MANUFACTURER'S RECOMMENDATIONS AND THESE
DRAWINGS ARE TO BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER AND
OWNER.
3. ANY CONTRACTOR INSTALLING ADHESIVE ANCHORING SYSTEMS SHALL BE TRAINED, IN
PERSON BY A MANUFACTURER'S REPRESENTATIVE, ON THE PROPER INSTALLATION
TECHNIQUES. THIS TRAINING SHALL INCLUDE PROPER DRILLING, HOLE CLEANING, AND
INSTALLATION METHODS FOR THE ADHESIVE ANCHORING SYSTEM AND CONSTRUCTION
CONDITIONS ON THIS PROJECT. ALL TRAINING TO BE CONDUCTED PRIOR TO CREWS STEPPING
ON SITE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT MANUFACTURER
REPRESENTATIVE TO SET UP TRAINING, ETS IS NOT RESPONSIBLE FOR ANY COST OCCURRED
FOR OR DURING ADHESIVE ANCHORING SYSTEM TRAINING.
SOIL COMPACTION
1. SUBGRADE PREPARATION
1.1. SHAPE TOP OF SUBGRADE TO THE LINES AND GRADES SHOWN ON THE DRAWINGS.
1.2. MAINTAIN TOP OF SUBGRADE IN A FREE-DRAINING CONDITION.
1.3. DO NOT STOCKPILE MATERIALS ON TOP OF SUBGRADE UNLESS AUTHORIZED BY
CONSTRUCTION MANAGER.
1.4. FOR SUBGRADES CONSISTING OF IN-PLACE NATIVE SOILS, SOILS SHALL BE FREE OF
CUTTING AND OTHER LOOSE MATERIAL AND SHALL MEET THE MINIMUM BEARING CAPACITY
REQUIREMENTS NOTES UNDER SOIL STRENGTH
1.5. FOR SUBGRADES CONSISTING OF PLACED STRUCTURAL FILL, STRUCTURAL FILL SHOULD
BE PLACED IN 6 INCH LIFTS AND COMPACTED TO A MINIMUM OF 95 PERCENT OF THE
MAXIMUM DRY DENSITY AS OBTAINED BY THE STANDARD PROCTOR METHOD
1.6. CONSTRUCT TOP OF SUBGRADE WITHIN ONE INCH OF ESTABLISHED GRADE AND
CROSS-SECTION.
SOIL STRENGTH
1. FOUNDATION DESIGN IS BASED ON A 2000 PSF SOIL BEARING CAPACITY. IF OTHER CONDITIONS
EXIST, FOUNDATION SHALL BE REDESIGNED. CONTRACTOR SHALL HAVE SOIL BEARING
CAPACITY VERIFIED BY A LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER PRIOR TO
INITIATION OF CONSTRUCTION ACTIVITIES.
1. FOR VERTICAL RUNS: ON TOWERS OR POLES, ALWAYS UNREEL THE SPOOL FROM THE TOP
DOWN. ENSURE NO STRAIN IS PLACED ON THE FIRST 3 FEET OF THE CABLE, AND THAT THE
CABLE IS SUPPORTED EVERY THREE FEET VERTICALLY. NEVER ALLOW THE CABLE TO
EXPERIENCE THE STRAIN OF THE CABLE SPOOL WEIGHT. ANY BENDS SHALL BE SUPPORTED
DIRECTLY ABOVE AND BELOW THE BEND. THE BOTTOM BEND SHALL HAVE A DRIP LOOP WITH A
MINIMUM ONE FOOT BEND RADIUS AT 120°. IT IS RECOMMENDED THE FIBER BE TESTED
BEFORE AND AFTER INSTALLATION FOR NO GREATER THAN .02 dB LOSS.
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
GENERAL NOTES III
GN-3
ABBREVIATIONSLINETYPES
ABC AGGREGATE BASE COURSE
ABS AIR BREAK SWITCH
A.C. ASBESTOS CEMENT
A/C AIR CONDITIONING
A.D. AREA DRAIN
A.F.F. ABOVE FINISHED FLOOR
ALT. ALTERNATE
ALUM. ALUMINUM
AMP. AMPERES
A.O. ACCESS OPENING
APPROX. APPROXIMATELY
ARCH. ARCHITECTURAL
ASPH. ASPHALT
A.T..P. ANTI-TERRORISM FORCE PROTECTION
A.W.W.A. AMERICAN WATER WORKS ASSOCIATION
BLDG. BUILDING
BM. BENCH MARK
BOC BACK OF CURB
BOL BOLLARD
BRG. BEARING
BVC BEGIN VERTICAL CURVE
BVCE BEGIN VERTICAL CURVE ELEVATION
BVCS BEGIN VERTICAL CURVE STATION
C&G CURB AND GUTTER
CATV CABLE TELEVISION
CAP. CAPACITY
C.B. CATCH BASIN
CBL CABLE
CEM. CEMENT
CER. CERAMIC
C.F.M. CUBIC FEET/MINUTE
C.F.S. CUBIC FEET/SECOND
C.I. CURB INLET
C.I.P. CAST IRON PIPE
CIRC. CIRCULATING
C.A. CONSTRUCTION JOINT/CONTRACTION JOINT
C.L. CENTER LINE
C.A. CONCRETE MONUMENT
C.M.P. CONCRETE METAL PIPE
C.M.U. CONCRETE MASONRY UNIT
C.O. CLEAN OUT
COL. COLUMN
CONC. CONCRETE
COND. CONDENSATE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
COR CONTRACTING OFFICERS REPRESENTATIVE
C.TO C. CENTER TO CENTER
C.Y. CUBIC YARD
DET. DETAIL
DI DROP INLET
DIA. DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
D.I.P. DUCTILE IRON PIPE
DISC. DISCONNECT
D.J. DUMMY JOINT
DN. DOWN
DR. DRAIN
D.S. DOWN SPOUT
DW DOMESTIC WATER
DWG.(S) DRAWING(S)
EA. EACH
E.F. EXHAUST FAN
EG. EXISTING GRADE
E.I.P. EXISTING IRON PIPE
E.J. EXPANSION JOINT
ELEC. ELECTRIC
EL. ELEVATION
E.M. ELECTRIC METER
EOP EDGE OF PAVEMENT
EQUIP. EQUIPMENT
EVC END VERTICAL CURVE
EVCE END VERTICAL CURVE ELEVATION
EVCS END VERTICAL CURVE STATION
EXH. EXHAUST
EXP.JT. EXPANSION JOINT
EXT. EXTERIOR
EX./EXIST. EXISTING
FC FACE OF CURB
F.D. FLOOR DRAIN
F.D.C. FIRE DEPARTMENT CONNECTION
F.E.S. FLARED END SECTION
F.F.E. FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FH FIRE HYDRANT
FIN. FINISH FLOOR
FM FORCE MAIN
FOC FACE OF CURB
FT. FOOT, FEET
FTG. FOOTING
GA GAGE
GAL. GALLON
GALV. GALVANIZED
GC GENERAL CONTRACTOR
G.F.E. GOVERNMENT FURNISHED EQUIPMENT
GIS GEOGRAPHIC INFORMATION SYSTEM
GL GAS LINE
GM GAS METER
G.P.H. GALLONS/HOUR
G.P.M. GALLONS/MINUTE
GND. GROUND
GOV'T GOVERNMENT
GV GATE VALVE
GW GUY WIRE
HC HANDICAP
HCP HANDICAP PARKING
HCR HANDICAP RAMP
HDW HEADWALL
HP HIGH POINT
HSS HIGH STRENGTH STEEL
HT HEIGHT
HYD HYDRANT
ID. INSIDE DIAMETER
INTX. INTERSECTION
INV. INVERT
ISL ISLAND
ITL. INDEPENDENT TESTING LABORATORY
J.B. JUNCTION BOX
JCT. JUNCTION
JSOC JOINT SPECIAL OPERATIONS COMMAND
JT. JOINT
K K VALVE
KVA KILOVOLT AMPERE
KW KILOWATT
L LENGTH
LF LINEAR FEET
LGT LIGHT
LP LIGHT POLE
LT LEFT
MAX MAXIMUM
MED MEDIAN
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
MON MONUMENT
MTL METAL
MW MONITOR WELL / MICROWAVE
M.U.T.C.D MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
N/A NOT APPLICABLE
NAD 27 NORTH AMERICAN DATUM 1927
NAD 83 NORTH AMERICAN DATUM 1983
NBL NORTH BOUND LINE
NC NORMAL CROWN
NEMA NATIONAL ELECTRICAL MANUFACTURES
ASSOCIATION
NIC NOT IN CONTRACT
NIP NEW IRON PIPE
N.T.S. NOT TO SCALE
O.U. ON CENTER
O.V. OUTSIDE DIAMETER
OH OVERHEAD
OHE OVERHEAD ELECTRIC
ONUS. OLD NORTH UTILITY SERVICE
OVH OVERHANG
P/A PARKING AREA
PC POINT OF CURVATURE
PCC POINT OF COMPOUND CURVATURE
PED PEDESTAL
PER. PERIMETER
PGL PROPOSED GRADE LINE
PI POINT OF INTERSECTION
PINC POINT OF INTERSECTION ON CURVE
PIV POST INDICATOR VALVE
PIV ELEV POINT OF VERTICAL INTERSECTION ELEVATION
PLT PLATE
PSF POUNDS PER SQUARE FOOT
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
PIV STA POINT OF VERTICAL INTERSECTION STATION
PT POINT
PVMT PAVEMENT
RAD. RADIUS
RCP REINFORCED CONCRETE PIPE
REINF. REINFORCING
REQ. REQUIRED
REV REVISED
R.P.Z. REDUCED PRESSURE ZONE
RT RIGHT
R/W RIGHT OF WAY
RWM RIGHT OF WAY MONUMENT
SAN SANITARY SEWER
SB SOIL BORING
SCH SCHEDULE
SET SETBACK
SF SQUARE FEET
SHT SHEET
SIA SIAMESE CONNECTION
SIG SIGNAL
SOTF SECURITY OPERATIONS TRAINING FACILITY
SP SIGNAL POLE
SPECS SPECIFICATIONS
SQFT SQUARE FEET
SR STATE ROAD
SS SANITARY SEWER
STA. STATION
STD. STANDARD
STM STORM
STL STEEL
SW SIDEWALK
SWM. STORMWATER MANAGEMENT
T TANGENT
TBM TEMPORARY BENCHMARK
TERR TERRA COTTA PIPE
TEL TELEPHONE
TOC TOP OF CURB
TOB TOP OF BANK
TOS TOP OF SLOPE
TOW TOP OF WALL
TP TELEPHONE POLE
TRANS TRANSFORMER
TYP. TYPICAL
U/C UNDER CONSTRUCTION
U/G UNDERGROUND
UNO UNLESS NOTED OTHERWISE
UP UTILITY POLE
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VIF VERIFY IN FIELD
WL WATER LINE
WM WATER METER
WSEL WATER SURFACE ELEVATION
WV WATER VALVE
WTR WATER
WWF WIRE WELD FABRIC
AL4RPV AL4RPV
FSJ4-50 FSJ4-50
HL4RPV HL4RPV
FSJ1-50 FSJ1-50
LMR-240 LMR-240
PTS1-50 PTS1-50
LDF1-50 LDF1-50
OHF OHF OHF
UGF UGF UGF UGF
TFT-402 TFT-402
SMF SMF SMF
MMF MMF MMF
SM288 SM288
SM144 SM144
SM96 SM96 SM96
SM48 SM48 SM48
SM24 SM24 SM24
SM12 SM12 SM12
SM6 SM6 SM6
LDF4-50 LDF4-50
CAT6 CAT6 CAT6
COAX COAX COAX
C C C
ETH ETH ETH
GAS GAS GAS
GND GND GND
CAT5 CAT5 CAT5
DCP DCP DCP
ACP ACP ACP
OHP OHP OHP
UGW UGW UGW
R/W R/W R/W
SF SF SF
PARENT PROPERTY BOUNDARY
ADJACENT PROPERTY BOUNDARY
EASEMENT
LEASE AREA
RIGHT OF WAY
SILT FENCE
X X X XCHAIN-LINK FENCE
UNDERGROUND WATER
UGP UGP UGP UGPUNDERGROUND POWER
OVERHEAD POWER
ALTERNATING CURRENT POWER
DIRECT CURRENT POWER
FO/DC FO/DC FO/DC
HYBRID HYBRID
FIBER/DC POWER COMPOSITE CABLE
HYBRID CABLE
UNDERGROUND FIBER
OVERHEAD FIBER
MULTI-MODE FIBER
SINGLE-MODE FIBER
FIBER TRUNK - 6 STRAND
FIBER TRUNK - 12 STRAND
FIBER TRUNK - 24 STRAND
FIBER TRUNK - 48 STRAND
FIBER TRUNK - 96 STRAND
FIBER TRUNK - 144 STRAND
FIBER TRUNK - 288 STRAND
GROUND WIRE
GAS LINE
ETHERNET CABLE
ALM ALM ALM
CAT6 CABLE
CAT5 CABLE
ALARM CABLE
CONDUIT
COAX FEEDLINE
COAX FEEDLINE / JUMPER - TFT-402
COAX FEEDLINE / JUMPER - PTS1-50
COAX FEEDLINE / JUMPER - LMR-240
COAX FEEDLINE / JUMPER - LDF4-50
COAX FEEDLINE / JUMPER - LDF1-50
COAX FEEDLINE / JUMPER - HL4RPV
COAX FEEDLINE / JUMPER - FSJ4-50
COAX FEEDLINE / JUMPER - FSJ1-50
COAX FEEDLINE / JUMPER - AL4RPV
R/W
R/W
R/W R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/WR/WR/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/WR/WR/WR/WR/WR/W
R/W
R/W
R/W
R/W
R/WR/WR/WR/WR/W
R/W
R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
X
1. SITE PLAN BASED ON SURVEY COMPLETED BY JMT DATED 03/11/2025.
2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS
INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION
MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND
DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD.
ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT
ASSUME RESPONSIBILITY FOR THIS CONTENT.
NOTES
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
OVERALL PROPERTY
PLAN
C-1.0
PROPOSED 120'±
MONOPOLE SETBACKS
PROPERTY BOUNDARY LINEDISTANCE
NORTH291'-1"±
EAST195'-6"±
SOUTH515'-5"±
WEST216'-3"±
N
NW
W
SW
S
SE
E
NE
NNW
WNW
WSW
SSW SSE
ESE
ENE
NNE
1" = 200'-0"
OVERALL PROPERTY PLAN
PARENT PROPERTY
OWNER: CAROLINA
POWER & LIGHT
PARCEL: 2060002010
ACRES: 3.3
EXISTING ACCESS ROAD
SITE PLAN DATA TABLE
OWNER OF RECORDCAROLINA POWER & LIGHT CO DUKE ENERGY CENTER
550 S TRYON STREET CHARLOTTE, NC 28202
APPLICANTDUKE ENERGY PROGRESS INC
150 FAYETTEVILLE STREET, BOX 1011 HICKORY, NC 28601
PRIMARY CONTACT SSEE T-1
PROJECT ADDRESS2434 WEDGEFIELD RD. SUMTER, SC 29154
TAX MAP IDENTIFICATION NUMBER206-00-02-010
WITHIN SUMTER CITY LIMITSYES
PROPOSED USE120' UTILITY POLE FOR DUKE ENERGY INTERNAL USE FOR
SUBSTATION REMOTE ACCESS
ZONING DISTRICTR-15
MINIMUM DEVELOPMENT
REQUIREMENTS
MINIMUM LOT AREA PER INDIVIDUAL UNIT N/A
MINIMUM LOT WIDTH100 FT.
MINIMUM LOT DEPTH120 FT.
MINIMUM YARDS, PER STRUCTURE
FRONT35 FT.
SIDE50 FT.
REAR50 FT.
MAXIMUM IMPERVIOUS SURFACE PERCENTAGE0.4
MAXIMUM DENSITY (UNITS PER GROSS ACRE)N/A
MAXIMUM HEIGHT OF BUILDINGS45 FT.
FEMA FLOODPLAIN INSURANCE MAP
INFORMATIONMAP NUMBER 45085C0292E EFFECTIVE ON 10/27/2022
SIZE OF PARCEL10.0 ACRES
SIZE OF SITE PLAN0.8043
PERCENTAGE OF PARCEL UNDEVELOPED0.08
EXISTING BUILDINGSN/A
WEDGEFIELD ROAD
FREEDOM
BOULEVARD
GRIFFIN LN
W OAKLAND AVENUE
STILLPOINTE DRIVE
CONIFER STREET
CONIFER STREET
ACON STREET
ADJACENT PROPERTY
OWNER: HUTCHISON RYAN MILLER
PARCEL: 2060701010
ACRES: 0.70
ADJACENT PROPERTY
OWNER: COLLINS DONNIE & MIRIAM
PARCEL: 2060701011
ACRES: 0.59
ADJACENT PROPERTY
OWNER: CLARK LETHALIE KATHY
PARCEL: 2060701012
ACRES: 0.59
ADJACENT PROPERTY
OWNER: BRUNSON STEVE S & THELMA T
PARCEL: 2060701013
ACRES: 0.59
ADJACENT PROPERTY
OWNER: NASH DAVID R
PARCEL: 2060701014
ACRES: 0.59
ADJACENT PROPERTY
OWNER: GAINEY CONSTRUCTION CO LLC
PARCEL: 2060701074
ACRES: 0.60
ADJACENT PROPERTY
OWNER: PALMETTO PROPERTIES OF SUMTER
PARCEL: 2060701016
ACRES: 0.23
ADJACENT PROPERTY
OWNER: JSAL ENTERPRISES LLC
PARCEL: 2060701017
ACRES: 0.22
ADJACENT PROPERTY
OWNER: JSAL ENTERPRISES LLC
PARCEL: 2060701018
ACRES: 0.24
ADJACENT PROPERTY
OWNER: PALMETTO PROPERTIES OF SUMTER
PARCEL: 2060202006
ACRES: 0.41
ADJACENT PROPERTY
OWNER: MAY SALLY ROBINSON ESTATE
PARCEL: 2060202004
ACRES: 0.63
ADJACENT PROPERTY
OWNER: ALI JORDAN BASSET & JUSTIN ROB
PARCEL: 2060701019
ACRES: 0.39
ADJACENT PROPERTY
OWNER: BURKIN DAVID S & RANDI L
PARCEL: 2060701021
ACRES: 0.21
ADJACENT PROPERTY
OWNER: HERBERT PAUL G & MARY A
PARCEL: 2060701022
ACRES: 0.53
ADJACENT PROPERTY
OWNER: DAVIS-FREEMAN JUANA L
PARCEL: 2060701023
ACRES: 0.57
ADJACENT PROPERTY
OWNER: ASANTE DELANO YAW
PARCEL: 2060701024
ACRES: 0.60
ADJACENT PROPERTY
OWNER: DOBATO DE COOK CONCEPCION
PARCEL: 2060701025
ACRES: 0.68
ADJACENT PROPERTY
OWNER: YOMTOB JESSE A
PARCEL: 2060701026
ACRES: 0.62
ADJACENT PROPERTY
OWNER: ROGERS KENNETH & MARLENE
PARCEL: 2060701027
ACRES: 0.50
PROPOSED 120'± MONOPOLE
FALLZONE
GNDGNDGNDGND GND
GND GNDGNDGND
GND
GND
GND
GND
UGF
X X X X X X X X X X X X X X
XXXXXXXXX
XXXXXXXXX
X
X
XX
X X X X X X X
GND
GND
GND
GNDGND
GND GNDGND
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
SUBSTATION
COMPOUND PLAN
C-1.1
N
NW
W
SW
S
SE
E
NE NNW
WNW
WSW
SSWSSE
ESE
ENE
NNE
1" = 20'-0"
SUBSTATION COMPOUND PLAN
EXISTING SUBSTATION EQUIPMENT
(TYP.)
PROPOSED DUKE ENERGY 120'± MONOPOLE W/ CAMBIUM EQUIPMENT
(SEE SHEET C-2)
PROPOSED COMMUNICATION POLE BASE
GROUNDING BONDED TO EXISTING
SUBSTATION GROUND MAT
(SEE SHEETS C-1.2 & C-3.2)
PROPOSED BURIED 2" CONDUITS
(1) W/ CAT5E CABLE (CAMBIUM P/N: WB3176A) (~45')
(1) EMPTY FOR FUTURE USE
(SEE SHEET C-1.3)
EXISTING TELECOM
EQUIPMENT CABINET
35'-0"
10'-0"
36'-8"
4'-0"
4'-0"
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
TRANSMISSION
GROUNDING PLAN
C-1.2 N.T.S.
TRANSMISSION GROUNDING PLAN
FOR REFERENCE ONLYFOR REFERENCE ONLY
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
TRANSMISSION
CONDUIT PLAN
C-1.3 N.T.S.
TRANSMISSION CONDUIT PLAN
#DESCRIPTION & FUNCTIONSIZELENGTHSIZELENGTHREMARKS
82120' CAMBIUM POLE TO TELECOM EQUIPMENT CAB2" PVC50'CAT5E170'CABLE LENGTH INCLUDES TOWER HEIGHT
83120' CAMBIUM POLE TO TELECOM EQUIPMENT CAB2" PVC50'----SPARE
FOR REFERENCE ONLYFOR REFERENCE ONLY
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
COMMUNICATION
POLE ELEVATION &
ANTENNA PLAN
C-2 1/16" = 1'-0"
COMMUNICATION POLE ELEVATION
1" = 32'-0"
ANTENNA PLAN
0'-0"
FINISHED GRADE
N
NW
W
SW
S
SE
E
NE
NNW
WNW
WSW
SSW SSE
ESE
ENE
NNE
1. CONTRACTOR TO REFER TO MOST
RECENT TOWER ANALYSIS, COMPLETED
BY ENGINEERED TOWER SOLUTIONS,
PRIOR TO INSTALLATION.
2. COMMUNICATION POLE TO BE A
GALVANIZED STEEL COLOR TO BLEND
IN WITH EXISTING TRANSMISSION LINE
EQUIPMENT.
3. COMMUNICATION POLE INTENDED FOR
DUKE ENERGY EQUIPMENT ONLY. NO
TENANTS ARE PERMITTED TO
CO-LOCATE ONTO COMMUNICATION
POLE.
NOTES
120'-0"
TOP OF COMMUNICATION POLE
SIZE
(FT)TYPE MANUFACTURER PART #ELEVATION
(FT)AZIMUTHMOUNT
4'ANTENNARADIOWAVESHPD4-5.2118'-0"103.54°
SITE PRO 1 DCH8
CHAIN MOUNT 5.3"x10.3"x3.3"ODUCAMBIUM NETWORKSPMP450i
NON-INTEGRATED |118'-0"--
96.0"x14.6"x8.7"LTE ANTENNA
(FUTURE)JMA(9) X7CQAP-86-880-VR060'--
PV-LPPGS-12M-HR2-
AP19-AT
(12.5 FT PLATFORM
MOUNT)
27.20"x12.05"x7.0
"RRUS (FUTURE)ERICSSON(9) RRUS 3260'--
31.41"x18.28"x9.6
6"
SURGE
SUPPRESSOR
(FUTURE)
RAYCAP(3) DC6-48-60-18-8C60'--
118'-0"
ANTENNA C.L.
124'-0"
TOP OF LIGHTNING ROD
60'-0"
FUTURE ANTENNA C.L.
AZIMUTH
103.54
°
PROPOSED DUKE ENERGY 120'±
MONOPOLE
PROPOSED DUKE ENERGY MW
DISH ANTENNA
PROPOSED DUKE ENERGY
CHAIN MOUNT
PROPOSED DUKE ENERGY
CAMBIUM ODU
PROPOSED DUKE ENERGY
STABILIZER BAR
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
DETAILS I
C-3.1 CHAIN MOUNT DETAIL
N.T.S.
VALMONT - TCHM1
·TAPER ADJUSTABLE CHAIN MOUNT
·FITS POLYGON OR ROUND POLES
·ALLOWS FOR UP TO 6° OF TAPER IN 3/4° INCREMENTS
·INCLUDES U-BOLTS FOR MOUNTING 2-3/8" OR 4-1/2" OD PIPES
·MOUNTING PIPE ORDERED SEPARATELY
N.T.S.
U-BOLTS INCLUDED
FOR 2-3/8" OR 4-1/2" OD
MOUNTING PIPES
5'-0"x4-1/2" OD SCH.40
ANTENNA MOUNTING PIPE
(ORDERED SEPARATELY )
5'-0"
4-1/2" OD
ODU DETAIL
N.T.S.
CAMBIUM NETWORKS - PMP 450i
N.T.S.
HEIGHTWIDTH DEPTHWEIGHT ANTENNA CONNECTORFREQUENCY
10.3" 5.3" 3.3" 4.5 LBS(2) N-TYPE FEMALE3 GHz: 3300 - 3900 MHz
5 GHz: 4900 - 5925 MHz
WIDTH
DEPTH
HEIGHT
2'-0"x2-3/8" OD SCH.40
ODU MOUNTING PIPE
(ORDERED SEPARATELY)
ODU MOUNTING DETAIL
N.T.S.
5'-0"x4-1/2" OD SCH.40
ANTENNA MOUNTING PIPE
ODU MOUNTED TO 2'-0"x2-3/8"
OD SCH.40 MOUNTING PIPE
PER MANUFACTURER
SPECIFICATIONS MOUNTED
ON BACKSIDE OF PIPE
ADAPTER CLAMP SET
ANTENNA
(BEYOND)
ADAPTER CLAMP SET
(ANDREW AD-P60-SCP)
ADAPTER CLAMP SET: ANDREW - AD-P60-SCP
·FITS PIPES 4-1/2" TO 12"
·INCLUDES (4) 1/2"x4" THREADED RODS / HARDWARE
·INCLUDES (4) 5/8"x8" THREADED RODS / HARDWARE
·ODU MOUNTING PIPE ORDERED SEPARATELY
LPU MOUNTED TO 2'-0"x2-3/8"
OD SCH.40 MOUNTING PIPE
PER MANUFACTURER
SPECIFICATIONS
ANTENNA DETAIL
N.T.S.
RADIOWAVES - HPD4-5.2
N.T.S.
DIAMETERWEIGHT ANTENNA CONNECTORFREQUENCY
4'-0"85 LBS N-TYPE FEMALE5.25 - 5.85 GHz
radiowaves
DIAMETER
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
DETAILS II
C-3.2
COMMUNICATION POLE BASE DETAIL (SIDE VIEW)
N.T.S. N.T.S.
CAT5E CABLE UP TO EQUIPMENT
2" WEATHERHEAD
(TYP.)
MAIN GROUND BAR MOUNTED
TO COMMUNICATION POLE
BASE
GND GND GND GND GND GND GND GND
GND
GND
GNDGNDGNDGNDGND
GND
EXISTING GROUND GRID
2/0 AWG, CU, SOFT DRAWN, 19 STR,
INSULATED THWN CONDUCTOR
(TYP.)
COMMUNICATION POLE BASE DETAIL (FRONT VIEW)
N.T.S. N.T.S.
MAIN GROUND BAR MOUNTED
TO COMMUNICATION POLE
BASE
2/0 AWG, CU, SOFT DRAWN, 19 STR,
INSULATED THWN CONDUCTOR
(TYP.)
EXISTING GROUND GRID
(2) 2" PVC CONDUITS TO BASE
EQUIPMENT
(1) W/ CAT5E CABLE
(1) EMPTY FOR FUTURE USE
(SEE SHEET C-1.1 FOR ROUTE)
CAT5, 4 PAIR 24 AWG, CU
SHIELDED INSULATION ROUTED
ON EXTERIOR OF POLE
2" WEATHERHEAD
(TYP.)
GNDGNDGNDGNDGNDGNDGNDGNDGND
2'-0"
MIN.
5'-0"
GNDGNDGNDGNDGNDGNDGNDGND
GND
GND GND
GNDGND
GND
GND
2" SCH. 40 GRAY
PVC CAP
GNDGNDGNDGNDGNDGNDGNDGND
GND
CAT5, 4 PAIR 24 AWG, CU
SHIELDED INSULATION ROUTED
ON EXTERIOR OF POLE
(SEE CABLE ROUTING DETAIL)
UPPER TOWER GROUND BAR,
2" WD X 12" LG X 1/4" THK, W/
INSULATORS & BRACKETS,
(18) PRE-DRILLED 7/16" HOLES
MECHANICAL BOND GROUND
WITH COMPRESSION LUGS
(TYP.)
2/0 AWG, CU, SOFT DRAWN, 19 STR,
INSULATED THWN CONDUCTOR
(TYP.)
2/0 AWG, CU, SOFT DRAWN, 19 STR,
BARE COPPER, CLASS B
CONNECTOR,ELECTRICAL, TERMINAL,
LUG, 2 AWG CONDUCTOR, (2) 3/8" HOLE
TERMINATION, BLACK, STD COMPRESSION
CONNECTOR, ELECTRICAL,
TERMINAL, LUG, 2 AWG
CONDUCTOR, (2) 3/8" HOLE
TERMINATION
CABLE HOISTING GRIP, 3/8"
CABLE, SS, PRE-LACED
STANDOFF BRACKET WITH
STACKABLE SNAP-IN HANGER
(TYP.)
ENLARGED COMMUNICATION POLE TOP DETAIL
N.T.S.
GNDGND
GND
GND
GNDGNDGNDGNDGND
GND
GND
GND
GNDGNDGNDGND
GND GND GND GND GND
GNDGNDGND
GND GND GND GND GND GNDGNDGND
GND GNDGNDGND
PARABOLIC ANTENNA MOUNTED TO
5'-0"x4-1/2" OD SCH.40 PIPE PER
MANUFACTURER SPECIFICATIONS CHAIN MOUNT
4'-0"x1/2"Ø COPPER CLAD AIR
TERMINAL INTERNALLY THREADED
CAT5, 4 PAIR 24 AWG, CU
SHIELDED INSULATION ROUTED
ON EXTERIOR OF POLE
(SEE CABLE ROUTING DETAIL)
ODU MOUNTED TO 2'-0"x2-3/8" OD
SCH.40 PIPE PER MANUFACTURER
SPECIFICATIONS
CABLE GROUNDING KIT
LPU MOUNTED TO 2'-0"x2-3/8" OD
SCH.40 PIPE PER MANUFACTURER
SPECIFICATIONS
UPPER TOWER GROUND BAR
MECHANICAL BOND GROUND
WITH COMPRESSION LUGS
(TYP.)
2/0 AWG, CU, SOFT DRAWN, 19 STR,
INSULATED THWN CONDUCTOR
(TYP.)
SEE ENLARGED COMMUNICATIONS
POLE TOP DETAIL
COMMUNICATION POLE TOP DETAIL
N.T.S.
GND
GND
GNDGND
GND
GNDGND
GND GND
GNDGND
GND GND GND
GND
GND GND GND
GND
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
DETAILS III
C-3.3
WIRE/CABLE, 2/0 AWG, CU, SOFT
DRAWN, 19 STR, BARE COPPER,
CLASS B TIED TO GROUND BAR
(SEE NOTES)
NOTES:
·DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND
WIRE DOWN TO GROUND BAR
·GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO-HOLE LUG
·WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT;
COLD SHRINK SHALL NOT BE USED
FEEDLINE CABLE GROUNDING DETAIL
N.T.S.
1'-0" TO 2'-0"
2 1/2" Ø MAX.
WEATHERPROOFING KIT
(SEE NOTES)
FEEDLINE CABLE
CABLE GROUND KIT
N.T.S.
3/4" STAINLESS STEEL BANDING
(ATTACHED TO EXTERIOR OF MONOPOLE)
CABLE ROUTING DETAIL
CAT5E CABLE
SNAP-IN HANGER W/
SINGLE-HOLE BARREL CUSHION
(VALMONT P/N: CIN3812)
3'-0"
3'-0"
SNAP-IN ASSEMBLY
(SEE DIAGRAM)
STANDOFF BRACKET
(VALMONT P/N: MST-U)
CAT5E CABLE
COMMUNICATION POLE
SNAP-IN ASSEMBLY
CADWELD GROUNDING DETAIL
N.T.S.
GROUND WIRE
(TYP.)
GROUND ROD
CADWELD
(TYP.)
NOTES:
·MINIMUM SPACING OF 1'-0" BETWEEN ALL CADWELDS.
·TOP VIEW DETAIL ONLY TO BE USED AT SPLICE LOCATIONS.
TOP VIEW
SIDE VIEW
GROUND WIRE
(TYP.)
GROUND ROD
CADWELD
(TYP.)
TRENCH DETAILS
N.T.S.
PROPOSED WARNING TAPE
(6"-8" BFG)
4"2"
PROPOSED 2" CONDUIT
RESTORE SURFACE COURSE
AND BASE MATERIAL TO
ORIGINAL CONDITION
GRAVEL BASE COMPACTER
TO 95% STANDARD PROCTOR
MAXIMUM DRY DENSITY
NATIVE SOIL
4"
(TYP.)
FINISHED GRADE (GRAVEL)
4"
(TYP.)
4"
(TYP.)
PROPOSED 2"
SPARE CONDUIT
POLE SLIP JOINT DETAIL
N.T.S.
NOTE:
IF POLE SECTIONS ARE JACKED TOGETHER PRIOR TO LIFTING AND SETTING THE POLE IN THE
HOLE, THE POLE SECTIONS SHALL BE BOLTED AT THE SLIP JOINTS
1'-0"6"
7/8"x48" BOLT W/ 7/8" WASHER,
BOLT & LOCK WASHER
(TYP.)
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
DETAILS V
C-3.4
1
2 3
25
2'-0"
MIN.
10
19
20
15
12
16
10
24
27
2
5'-0"
11
9
13
14
19
19
10
17
18
22
10
T1
T1
T2
20
11
T3
T6
T4
2
GNDGNDGNDGNDGNDGNDGNDGND
GND GNDGNDGNDGNDGNDGNDGNDGNDGND
GNDGNDGNDGNDGNDGNDGNDGND
GND
GND GND
GNDGND
GND
GND
5
3
5
GND
5
2
3
T5T5
8
26
6
6
GND
GNDGND
GND
GND GND
3
GNDGND
GND GND
GNDGND
GND GND GND
GND
GND GND GND
GND
3
3
29
28
TRANSMISSIONS
ITEMQTYUIMAXIMO P/NDESCRIPTIONNOTES
T1 TBD EA 61354CONDUIT, RIGID, HEAVY WALL, 2", 10' LG, SCH 40, PVC, LG BELLED ONE END, RATED F/ 90 DEG C2" x 10'-0" SCH. 40 GRAY PVC W/ COUPLING ON ONE END
T2 2 EA 79433ELBOW,CONDUIT, RIGID, 2", GRAY PVC, 90 DEG, 9-1/2" RADIUS, PLAIN END, F/ 2" CONDUIT;
PACKAGING: 15 PER PACK2" x 9-1/2" RADIUS SCH. 40, 90 DEGREE PVC ELBOW
T316 FT 4177461WIRE/CABLE, ELECTRICAL, BARE, GROUND, 19 STR SOL SD, 9 AWG, DEAD SOFT ANNEALED
COPPERCLAD
2 CONNECTIONS / POLE ASSUME MINIMUM 2' ABOVE 4'
BELOW
T4 1 BX50130218POWDER, WELDING, EXO., #300PLUS20, LIGHT GREENCAD WELD 4 PER POLE 10 CARTRIGES /BOX
T52 EA67295TERMINAL, TIN PLTD CU CONDUCTOR, WELDED CONDUCTOR CONNECTION, (2) 1/2" HOLE 1-3/4"
CTRPOLE HOLE PATTERN TO CAD WELD 9X19 TO GRID MAT
T61N/AEXISTING SUBSTATION GROUND MAT2 CONNECTIONS TO GRID MAT ASSUME 4' DEPTH
ITEMQTYUIMAXIMO P/NDESCRIPTIONNOTES/ENGINEERING RULE
1 1 EA 1505632AIR TERMINAL, COPPER CLAD AIR BASE, 1/2" DIA. X 48"MOUNT THE LIGHTNING ROD 180° AWAY FROM DISH POSITION
2 1 RO 4177461WIRE/CABLE, 2/0 AWG, CU, SOFT DRAWN, 19 STR, BARE CU, CLASS B, PACKAGED IN
25' HAND COILSAPPROXIMATELY 16' REQUIRED
3 6 EA 1503888TERMINAL, LUG, 2/0 AWG CONDUCTOR, (2) 1/2" HOLE BLACK, 1-3/4" CTRFITS EVERY BONDING CONNECTOR WELDED TO VALMONT H-10 POLE
4 1 EA 1612775TERMINAL, LUG, 2/0 AWG CONDUCTOR, (2) 1/2" HOLE, 1" CTR , BLACK, LONGNEED 2 PER POLE - 2 ON LOWER GROUND BAR, (MAIN GNDS AT BOT)
1 ON UPPER
53 EA 1504572TERMINAL, LUG, 2/0 AWG, COMP , CU , (2) 3/8" HOLE, 1" CTRNEED 1 PER POLE - 1 ON UPPER GND BAR ( MAIN GND AT TOP) 2 ON
LOWER
6 2 EA 1505554TERMINAL, LUG, 2/0 AWG CONDUCTOR, SGL HOLE 3/8" POST F/2/0 AWG SINGLE HOLE 2 PER POLE, BOND FOR THE 4.5”& 2.5” PIPE
73EA LOOSETERMINAL, LUG, # 6 AWG , (2) 1/2" HOLE, 1 3/4" SPACE BLUE, LONGUSED FOR MID CAT-5 BOND TO POLE GROUND NEW PART
81EA 1525371BAR, GROUND, 2" WD X 12" LG X 1/4" THK, W/ INSULATORS & BRACKETS, (18)
PRE-DRILLED 7/16" HOLEBAR, GROUND - ENGINEERING RULE = TOP GROUND BAR - VERT
91 EA1505048BAR, GROUND, BUSS, 4" WD X 14" LG X 1/4" THK, TINNED, W/ HARDWAREBAR, GROUND - ENGINEERING RULE = BOTTOM GROUND BAR -
HORIZ 3/4", 1" AND 1-3/4" ON CENTER
101 KT1539777LPU KIT, GROUNDING, LIGHTNING PROTECTION UNIT, ETHERNET CABLE,
PRE-FITTED CABLE GLAND,ENGINEERING RULE = 1 LPU KIT PER OSP CAT-5 CABLE (2 PER KIT)
11 1SP 1539773WIRE/CABLE,ELECTRICAL, CAT5, 4 PAIR, 24 AWG, CU, SHIELDED INSULATIONENGINEERING RULE = SPOOL 328' - POLE 120' RADIO TO LPU
MAXIMUM DISTANCE TO ISP PSU = 320'
12 4 PK1473338BRACKET, STANDOFF, MOUNTING, UNIVERSAL, NO ADAPTERBRACKET - 10/BAG ENGINEERING RULE = 1 EVERY 3 FEET
13 4 PK 1505037HANGER, CABLE, SNAP-IN STACKABLE, F/ 1-5/8" CABLESNAP-IN, 10/BAG - ENGINEERING RULE = 1 EVERY 3 FEET
14 4 PK 1564840CUSHION, BARREL, 1-5/8", UNIVERSAL, 14-36MM, SNAP-IN, 10 PER BOXBARREL CUSHION, 10/BAG - ENGINEERING RULE = 1 EVERY 3 FEET
151 EA1554484GRIP,CABLE, HOISTING, 3/8" CABLE, SS, PRE-LACEDENGINEERING RULE = 1 PER CAT-5 RISER TOP & MID IF > 200'
161 EA1503531PIPE, 5' LG, ALUM, 4-1/2" OD, F/ ANTENNA MOUNTPIPE, 5' LG, ALUM, 4-1/2" OD, 1 per DISH
17 1 EA 1479381PIPE, 2-3/8", 2' LG, PLAIN ENDS, STL, F/ ANTENNA MOUNTPIPE, 2-3/8", 2' LG, 1 per Radio/LPU ASSY
181EA 1501289BRACKET, MOUNTING, HOT DIP GALV STL, BOOM GATE CLAMP SET, 4-1/2" TO 12", 60
DEG ANGLE LEGS
TOWER LEG CLAMP SET ENGINEERING RULE = 1 PER 2' RADIO/LPU
ASSY
19 3EA1539778KIT, SHIELD GROUNDING, GROUND STRIPS, MASTIC TAPE, ELECTRICAL TAPE,
GROUND BOLT & NUT, RETAINING ZIP TIES, F/
(1) AT BOTTOM
(1) AT MIDDLE (ABOVE SLIP JOINT)
(1) AT TOP OF MONOPOLE"
20 4 RO 1490605BAND,STRAPPING, 3/4" WD, 100' LG, 0.03" THK, 316 SS, 1800 LBBAND,STRAPPING, 3/4" ASSUME 6' DIAMETER & ALL OTHER MISC
2150 EA 1490606BUCKLE, BANDING, 3/4" WIDE, SSBUCKLE, BANDING, 3/4" WD, SS
22 2 EA904105HEAD,SERVICE ENTRANCE,RIGID,2",SLIP-ON,PVC,WEATHER HD,STD PKG/5WEATHER HEAD, 2" ALL TO BE SCHEDULE 40
231 EA1545989BRACKET, MOUNTING, CAMBIUM TILT BRACKET ASSYBRACKET, MOUNTING, CAMBIUM TILT BRACKET ASSY Engineering
Rule = 1 per PMP-450 REMOVE for 670
24 1 EA1546830MODULE, RADIO FREQUENCY, CAMBIUM 5X GHZ 450i INTEGRATED SUBSCRIBER
MODULE5 GHz PMP 450i Int SM
251 EA1588737CHAIN MOUNT, FLUSH ANTENNA, CHAIN MOUNT, TIE BACK ARMS, U-BOLTS, F/ DISH
ANTENNA W/ SIDE SUPPORT BRACKETS, F/ 4-1/2" DIA -
4' AND 6' DISH ONLY - DHC8 SA-B10 INCLUDES U-BOLTS FOR
MOUNTING 4-1/2'' OD PIPES AND SIDE-STRUT SUPPORT BRACKET
FOR TIE-BACK ARMS
262 EA1570020JUMPER, COAX, 3' LG, N MALE TO N MALE, LMR-400JUMPER, COAX, 3' LG, N MALE TO N MALE, LMR-400
27 1 EA1564958ANTENNA, PARABOLIC DISH, 5.25-5.85GHZ, N-FEMALE CONNECTOR, 4' HPDP, 34.9
DBI GAIN4' HPDP CAMBIUM NON-INTEGRATED PMP OR PTP APPLICATIONS
28 2 EA 1501100BRACKET, MOUNTING, STABILIZER BARS-STIFF ARM--
292EA 1624192BRACKET, MOUNTING, 8" WD X 8" LG X 6" HT, HOT DIP GALV STL--
R/W
R/W
R/W R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/WR/WR/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/WR/WR/WR/WR/WR/W
R/W
R/W
R/W
R/W
R/WR/WR/WR/WR/W
R/W
R/W R/W R/W R/W R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
X
1. SITE PLAN BASED ON SURVEY COMPLETED BY JMT DATED 03/11/2025.
2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS
INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION
MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND
DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD.
ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT
ASSUME RESPONSIBILITY FOR THIS CONTENT.
NOTES
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SUBSTATION ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SUBSTATION NAME:
SUBSTATION TRANSMISSION NUMBER:
SUMTER WEDGEFIELD ROAD
230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
0
CHECKED BY: PB DRAWN BY: DF
07/24/2025
T3985
COA:
REV DATEDETAILS
0
1
2
3
07/24/2025 CONSTRUCTION
OVERALL PROPERTY
PLAN
C-1.0
PROPOSED 120'±
MONOPOLE SETBACKS
PROPERTY BOUNDARY LINEDISTANCE
NORTH291'-1"±
EAST195'-6"±
SOUTH515'-5"±
WEST216'-3"±
N
NW
W
SW
S
SE
E
NE
NNW
WNW
WSW
SSW SSE
ESE
ENE
NNE
1" = 200'-0"
OVERALL PROPERTY PLAN
PARENT PROPERTY
OWNER: CAROLINA
POWER & LIGHT
PARCEL: 2060002010
ACRES: 3.3
EXISTING ACCESS ROAD
SITE PLAN DATA TABLE
OWNER OF RECORDCAROLINA POWER & LIGHT CO DUKE ENERGY CENTER
550 S TRYON STREET CHARLOTTE, NC 28202
APPLICANTDUKE ENERGY PROGRESS INC
150 FAYETTEVILLE STREET, BOX 1011 HICKORY, NC 28601
PRIMARY CONTACT SSEE T-1
PROJECT ADDRESS2434 WEDGEFIELD RD. SUMTER, SC 29154
TAX MAP IDENTIFICATION NUMBER206-00-02-010
WITHIN SUMTER CITY LIMITSYES
PROPOSED USE120' UTILITY POLE FOR DUKE ENERGY INTERNAL USE FOR
SUBSTATION REMOTE ACCESS
ZONING DISTRICTR-15
MINIMUM DEVELOPMENT
REQUIREMENTS
MINIMUM LOT AREA PER INDIVIDUAL UNIT N/A
MINIMUM LOT WIDTH100 FT.
MINIMUM LOT DEPTH120 FT.
MINIMUM YARDS, PER STRUCTURE
FRONT35 FT.
SIDE50 FT.
REAR50 FT.
MAXIMUM IMPERVIOUS SURFACE PERCENTAGE0.4
MAXIMUM DENSITY (UNITS PER GROSS ACRE)N/A
MAXIMUM HEIGHT OF BUILDINGS45 FT.
FEMA FLOODPLAIN INSURANCE MAP
INFORMATIONMAP NUMBER 45085C0292E EFFECTIVE ON 10/27/2022
SIZE OF PARCEL10.0 ACRES
SIZE OF SITE PLAN0.8043
PERCENTAGE OF PARCEL UNDEVELOPED0.08
EXISTING BUILDINGSN/A
WEDGEFIELD ROAD
FREEDOM
BOULEVARD
GRIFFIN LN
W OAKLAND AVENUE
STILLPOINTE DRIVE
CONIFER STREET
CONIFER STREET
ACON STREET
ADJACENT PROPERTY
OWNER: HUTCHISON RYAN MILLER
PARCEL: 2060701010
ACRES: 0.70
ADJACENT PROPERTY
OWNER: COLLINS DONNIE & MIRIAM
PARCEL: 2060701011
ACRES: 0.59
ADJACENT PROPERTY
OWNER: CLARK LETHALIE KATHY
PARCEL: 2060701012
ACRES: 0.59
ADJACENT PROPERTY
OWNER: BRUNSON STEVE S & THELMA T
PARCEL: 2060701013
ACRES: 0.59
ADJACENT PROPERTY
OWNER: NASH DAVID R
PARCEL: 2060701014
ACRES: 0.59
ADJACENT PROPERTY
OWNER: GAINEY CONSTRUCTION CO LLC
PARCEL: 2060701074
ACRES: 0.60
ADJACENT PROPERTY
OWNER: PALMETTO PROPERTIES OF SUMTER
PARCEL: 2060701016
ACRES: 0.23
ADJACENT PROPERTY
OWNER: JSAL ENTERPRISES LLC
PARCEL: 2060701017
ACRES: 0.22
ADJACENT PROPERTY
OWNER: JSAL ENTERPRISES LLC
PARCEL: 2060701018
ACRES: 0.24
ADJACENT PROPERTY
OWNER: PALMETTO PROPERTIES OF SUMTER
PARCEL: 2060202006
ACRES: 0.41
ADJACENT PROPERTY
OWNER: MAY SALLY ROBINSON ESTATE
PARCEL: 2060202004
ACRES: 0.63
ADJACENT PROPERTY
OWNER: ALI JORDAN BASSET & JUSTIN ROB
PARCEL: 2060701019
ACRES: 0.39
ADJACENT PROPERTY
OWNER: BURKIN DAVID S & RANDI L
PARCEL: 2060701021
ACRES: 0.21
ADJACENT PROPERTY
OWNER: HERBERT PAUL G & MARY A
PARCEL: 2060701022
ACRES: 0.53
ADJACENT PROPERTY
OWNER: DAVIS-FREEMAN JUANA L
PARCEL: 2060701023
ACRES: 0.57
ADJACENT PROPERTY
OWNER: ASANTE DELANO YAW
PARCEL: 2060701024
ACRES: 0.60
ADJACENT PROPERTY
OWNER: DOBATO DE COOK CONCEPCION
PARCEL: 2060701025
ACRES: 0.68
ADJACENT PROPERTY
OWNER: YOMTOB JESSE A
PARCEL: 2060701026
ACRES: 0.62
ADJACENT PROPERTY
OWNER: ROGERS KENNETH & MARLENE
PARCEL: 2060701027
ACRES: 0.50
PROPOSED 120'± MONOPOLE
FALLZONE
View Map
CAROLINA POWER & LIGHT ATTN.
DUKE ENERGY CORPORATION
PO BOX 37996
CHARLOTTE NC 28237
Year 2024 2023 2022 2021
Market Land Value $130,000 $130,000 $130,000 $130,000
+ Market Improvement Value $0 $700 $700 $700
+ Market Misc Value $700 $0 $0 $0
= T otal Market/Exemption Value $130,700 $130,700 $130,700 $130,700
Assessed Land Value $0 $13,660 $13,660 $13,660
+ Assessed Improvement Value $0 $70 $70 $70
+ Assessed Misc Value $0 $0 $0 $0
= T otal Assessed Value $20 $13,730 $13,730 $13,730
Legal Residence Form
Mailing Address Change
Military Non-Resident
Land Use Units Unit Type Land Type Notes AgUse Value Market Land Value
UTIL (21) 5 Land Rate Code 9006 OPEN/CULTIVATED B38-C88 C-1 $0 $65,000
UTIL (21) 5 Land Rate Code 9006 OPEN/CULTIVATED INSUFNT R C-6 $0 $65,000
Apply for Ag Special Assessment
Description Size Units Market Value
LAND IMPROVEMENTS ONL Y (F 0 x 0 1 700
Click here to view the T ax Collector website.
Sale Date SalePrice Grantee Land Only Sale Deed Type
1/1/1993 $0 C
Summary
Parcel Number 206-00-02-010
Legal Description 10.0 AC - TR 1&2 -
District 17 - City of Sumter
Neighborhood S&W SUMTER, SUBURBAN
Location Address 2434 WEDGEFIELD RD
SUMTER 29154
Plat Book/Page PB|0000
Owners
Valuation
Land
Miscellaneous Improvement Information
T ax information
Sales
Sumter County, SC
Sale date range:
Search Sales by Neighborhood
Sales by Area
No data available for the following modules: Buildings, T ax History, Sketches.
Recent Sales in Area
From:
09/02/20
T o:
09/02/20
Distance:
1500
Units:
Feet
Search Sales by Distance
Map
Sumter County makes every effort to produce the most accurate information possible. No
warranties, expressed or implied, are provided for the data herein, its use or interpretation.
|
User Privacy Policy | GDPR Privacy Notice
Last Data Upload: 9/1/2025, 9:27:59 PM
Contact Us Developed by
Reference Copy
Duke Energy Business Services, LLC
0020991360
1330810
06/10/2025
Sumter, SC 29154
2434 Wedgefield Road
SUMTER
33- 54- 45.9 N 080- 23- 36.0 W
MTOWER
FAA Chapters NONE
Monopole
Page 1 of 2
ATTN: Telecommunications Div, CS03A
Duke Energy Business Services, LLC
401 South College Street
Charlotte, NC 28202
56.0
37.8
93.8
N/A
June 2021
FCC 854R
UNITED STATES OF AMERICA
FEDERAL COMMUNICATIONS COMMISSION
ANTENNA STRUCTURE REGISTRATION
OWNER:
FCC Registration Number (FRN):
Antenna Structure Registration Number
Issue Date
Location of Antenna Structure
County:
Ground Elevation (AMSL)
meters
Overall Height Above Ground (AGL)
meters
Latitude Longitude
NAD83
Overall Height Above Mean Sea Level (AMSL)
meters
Center of Array Coordinates Type of Structure
Painting and Lighting Requirements:
Conditions:
This registration is effective upon completion of the described antenna structur e and notification to the
Commission. YOU MUST NOTIFY THE COMMISSION WITHIN 5 DAYS OF COMPLETION OF
CONSTRUCTION OR CANCELLATION OF YOUR PROJECT, please file FCC Form 854. To file
electronically, connect to the antenna structure registration system by pointing your web browser to
https://www.fcc.gov/antenna-structure-registration. Electronic filing is required. Use purpose code “NT”
for notification of completion of construction; use purpose code “CA” to cancel yo ur registration.
The Antenna Structure Registration is not an authorization to construct radio facilities or transmit radio
signals. It is necessary that all radio equipment on this structure be covered by a valid FCC license or
construction permit.
You must immediately provide a copy of this Registration to all tenant licensees and permittees
sited on the structure described on this Registration (although not required, you may want to use
Certified Mail to obtain proof of receipt), and display your Registration Number at the site. See
reverse for important information about the Commission’s Antenna Structure Registration rules.
Reference Copy
Page 2 of 2
FCC 854R
You must comply with all applicable FCC obstruction marking and lighting requirements, as set forth in Part 17 of the
Commission’s Rules (47 C.F.R. Part 17). These rules include, but are not limited to:
• Posting the Registration Number: The Antenna Structure Registration Number must be displayed in a
conspicuous place so that it is readily visible near the base of the antenna structure. Materials used to
display the Registration Number must be weather-resistant and of sufficient size to be easily seen at the
base of the antenna structure. Exceptions exist for certain historic structures. See 47 C.F. R. 17.4(g)-(h).
• Inspecting lights and equipment: The obstruction lighting must be observed at least every 24 hours in
order to detect any outages or malfunctions. Lighting equipment, indicators, and associated devices must
be inspected at least once every three months.
• Reporting outages and malfunctions: When any top steady-burning light or a flashing light (in any
position) burns out or malfunctions, the outage must be reported to the nearest FAA Flight Service Station,
unless corrected within 30 minutes. The FAA must again be notified when the light is restored. The owner
must also maintain a log of these outages and malfunctions.
• Maintaining assigned painting: The antenna structure must be repainted as often as necessary to
maintain good visibility.
• Complying with environmental rules: If you certified that grant of this registration would not have a
significant environmental impact, you must nevertheless maintain all pertinent records and be ready to
provide documentation supporting this certification and compliance with the rules, in the event that such
information is requested by the Commission pursuant to 47 C.F.R. 1.1307(d).
• Updating information: The owner must notify the FCC of proposed modifications to this structure; of any
change in ownership; or, within 30 days of dismantlement of the structure.
Copies of the Code of Federal Regulations (which contain the FCC’s antenna structure registration rules, 47 C.F.R Part
17) are available from the Government Printing Office (GPO). To purchase CFR volumes, call (202) 512-1800. For
GPO Customer Service, call (202) 512-1803. For additional FCC information, consult the Antenna Homepage on the
internet at https://www.fcc.gov/antenna-structure-registration or call (877) 480-3201 (TTY 717-338-2824). June 2021
PRELIMINARY
NOT FOR CONSTRUCTION
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SITE ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SITE NAME:
SUMTER WEDGEFIELD
ROAD 230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
A
CHECKED BY: PB DRAWN BY: YA
COA:
REV DATEDETAILS
A 08/18/2025 PRELIMINARY
0
1
2
SCSMT017
SITE NUMBER:
N
NW
W
SW
S
SE
E
NE
NNW
WNW
WSW
SSW SSE
ESE
ENE
NNE
SITE PLAN
C-1
1. SITE PLAN BASED ON GOOGLE EARTH AERIAL IMAGERY
2. ALL INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY THAT ALL EXISTING INFORMATION IS AS
INDICATED ON THE SITE PLAN, AND NOTIFY THE CONSTRUCTION
MANAGER OF ANY DISCREPANCIES. ALL PERTINENT ITEMS AND
DIMENSIONS ARE RECOMMENDED TO BE VERIFIED IN THE FIELD.
ENGINEERED TOWER SOLUTIONS, PLLC IS NOT LIABLE AND DOES NOT
ASSUME RESPONSIBILITY FOR THIS CONTENT.
NOTES
N.T.S.
SITE PLAN
1 & 2
C-2.2
3 & 4
C-2.2
1 & 2
C-2.1
3 & 4
C-2.1
FREEDOM BLVD
WEDGEFIELD ROAD
NORTH LOCATION
SOUTH EAST LOCATION
NORTH WEST LOCATION
SOUTH WEST LOCATION
PROPOSED SITE
LOCATION
GRIFFIN LN
PRELIMINARY
NOT FOR CONSTRUCTION
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SITE ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SITE NAME:
SUMTER WEDGEFIELD
ROAD 230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
A
CHECKED BY: PB DRAWN BY: YA
COA:
REV DATEDETAILS
A 08/18/2025 PRELIMINARY
0
1
2
SCSMT017
SITE NUMBER:
ELEVATIONS
C-2.1
N.T.S.
1 - EXISTING NORTHWESTELEVATION
N.T.S.
2 - PROPOSED NORTHWEST ELEVATION
N.T.S.
4 - PROPOSED SOUTHWEST ELEVATION
N.T.S.
3 - EXISTING SOUTHWEST ELEVATION
PROPOSED DUKE ENERGY 120'-0"
MONOPOLE TOWER
PRELIMINARY
NOT FOR CONSTRUCTION
PREPARED BY:
3227 WELLINGTON COURT
RALEIGH, NC 27615
919-782-2710
www.ets-pllc.com
PREPARED FOR:
SEAL:
SITE ADDRESS:
2434 WEDGEFIELD ROAD
SUMTER, SC 29154
SITE NAME:
SUMTER WEDGEFIELD
ROAD 230 SUB
LATITUDE/LONGITUDE:
33.912755°, -80.393316°
SHEET #CURRENT REV #:
ETS #: 24131425
SHEET TITLE:
A
CHECKED BY: PB DRAWN BY: YA
COA:
REV DATEDETAILS
A 08/18/2025 PRELIMINARY
0
1
2
SCSMT017
SITE NUMBER:
ELEVATIONS
C-2.2
N.T.S.
1 - EXISTING NORTH ELEVATION
N.T.S.
2 - PROPOSED NORTH ELEVATION
N.T.S.
4 - PROPOSED SOUTHEAST ELEVATION
N.T.S.
3 - EXISTING SOUTHEAST ELEVATION
PROPOSED DUKE ENERGY 120'-0"
MONOPOLE TOWER
PROPOSED DUKE ENERGY 120'-0"
MONOPOLE TOWER