RecordWell Data

Supporting Materials

City of Goose Creek · Berkeley County · meeting of Oct 6, 2020 · Other

Open the original document More from City of Goose Creek

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

MARGUERITE BROWN MUNICIPAL CENTER CITY HALL COUNCIL CHAMBERS 519 N. GOOSE CREEK BLVD. GOOSE CREEK, SOUTH CAROLINA MEMORANDUM TO: MEMBERS OF THE PLANNING COMMISSION FROM: LILI ORTIZ-LUDLUM ADMINISTRATIVE ASSISTANT DATE: September 30, 2020 SUBJECT: NOTIFICATION OF PLANNING COMMISSION MEETING This is to remind everyone that the next meeting of the Planning Commission is scheduled for Tuesday , October 6, 2020, at 6:30 p.m. at City Hall. Should you have any questions or comments prior to Tuesday’s meeting, please do not hesitate to contact Brenda Moneer at (x.1116) or Mark Brodeur, Planning Director (x.1118) at 843‐797‐6220. MINUTES Page 1 of 4 MINUTES CITY OF GOOSE CREEK PLANNING COMMISSION TUESDAY, SEPTEMBER 1, 2020, 5:30 P.M. VIDEO CONFERENCE (ZOOM) I. CALL TO ORDER – CHAIRMAN JOSH JOHNSON Action: Chairman Johnson called the meeting to order at 5:30 p.m. Present: Heather Byrd; Paul Connerty; Judie Edwards; Josh Johnson; Jeffrey Smith; Gary Berenyi Absent: None Staff Present: Planning Director Mark Brodeur; Planning Technician Brenda Moneer Council Present: None II. APPROVAL OF AGENDA Motion: A motion was made to approve the agenda. Moved by Commissioner Smith; Seconded by Commissioner Edwards. Discussion: There was none. Vote: All voted in favor. The motion carried (7-0). III. REVIEW OF MINUTES: JULY 16, 2020 Motion: A motion was made to approve the minutes as submitted . Moved by Commissioner Edwards; Seconded by Commissioner Byrd. Discussion: There was none. Vote: All voted in favor. The motion carried (7-0). IV. PUBLIC HEARING: PROPOSAL TO AMEND THE CITY OF GOOSE CREEK ZONING ORDINANCE TO INCLUDE LANGUAGE AFFECTING ALL SECTIONS AND TABLES ESTABLISHING THE ZONING CLASSIFICATION HEAVY INDUSTRIAL DISTRICT (HI). Chairman Johnson stated there was a miscommunication with this agenda item as this was supposed to be a discussion item. He opened, presented the process for a Public Hearing, and asked City staff to present a Staff Report. Mr. Brodeur stated he would like to read his Staff Report for the record. Proposal: The proposal is to add a new Zoning classification in the City’s Zoning Code to accommodate heavier industrial uses in the City and more specifically to accommodate the present uses on the Century Aluminum’s Mt Holly campus. Background: Century Aluminum owns approximately 5,000 acres of property in the vicinity of the City, much of which is contiguous to the City and eligible for annexation into the City under the terms of an Annexation Agreement between the City and Century Aluminum. Under the terms Page 2 of 4 of the annexation agreement, the property has been divided into five parcels : Parcel A, Parcel B, Parcel C, Parcel D and Parcel E. The Mt. Holly industrial campus is located in this acreage on Parcel D, which consists of approximately 2,440 acres and is identified as TMS #223-000-0021. Other than the plant site, the Century Aluminum property is largely undeveloped and is surrounded by forest lands. The Mt. Holly smelter has a production capacity of 229,000 metric tons of aluminum per year. According to Century Aluminum, it is the most advanced plant of its kind in the United States, a pacesetter in production efficiency, energy utilization and environmental protection. This is a heavy industrial user. With over 310 employees, the facility would qualify as one of Goose Creek’s largest employers upon annexation. The plant has been active since 1980 and has been under the jurisdiction of Berkeley County. The annexation of the Century Aluminum property and the formation of a municipal electric utility to serve the Mt Holly aluminum smelter and other new developments within the Century Aluminum property, have been a top priority of the City Administrator, Mayor and City Council over the past 18 months. Once it was determined by Planning & Zoning Staff that a new zoning district would be the most efficient way of zoning the property for its current use upon annexation, Century Aluminum and the City worked diligently over several months to draft the proposed Heavy Industrial Zoning District description. The annexation of this property will be financially beneficial to the City and service f rom the city’s electric utility (at rates lower than those of its current supplier) will allow Century Aluminum to continue current operations at the Mt . Holly aluminum smelter and expand its production. The City anticipates the receipt of new property taxes, business license fee revenues , electric service revenues , and the development of new employment opportunities for City residents upon the occurrence of an anticipated plant expansion (within the existing Mt. Holly footprint). By the terms of the a nnexation agreement, Century Aluminum has already annexed Parcel A, Parcel B and Parcel C (properties along US HWY 176 and Old Mt. Holly Rd) into the City and such parcels have been designated with a zoning classification of General Commercial (GC). The City currently has two other Industrial Zoning Districts. One is the Light Industrial District (LI) and the other is the General Industrial District (GI). Both zones combined (approximately 177 acres) constitute less than 1% of the total land in the City. Planning & Zoning staff looked at simply amending the GI zone to accommodate heavy industrial uses. The GI zone was created in response to the annexation of JW Aluminum, and particularly its backlot – which is a 17.45- acre parc el. The nature of Century Aluminum’s smelting operation would not be permitted in the G I zoning designation. Revisions to the GI zone necessary to allow Mt. Holly’s operations would permit activities and buildings that would be inappropriate on the 17+acre site in such proximity to residential uses directly behind it. Discussion: The proposed Heavy Industrial zone would permit all current uses on the Century Aluminum’s primary campus. Absent the creation of the new zone, any of the City’s other zoning classifications would create non- compliance use throughout the site; that is not a desirable Page 3 of 4 outcome and should be avoided. The proposed zoning district seeks to avoid instances of non- compliance while permitting Mt. Holly’s existing uses to continue in their current form. Recommendation: Endorse the creation of a new Heavy Industrial Zoning District classification and forward your recommendation to City Council. Chairman Johnson inquired if anyone from the Public submitted comments regarding this topic. Mrs. Moneer stated she has not received anything. A representative from Century Aluminum was present to answer any questions. Chairman Johnson stated there are other industrial districts in the City. He stated it seems like we are trying to create a new zone for a specific user. He stated if a new zone is needed, then he feels this would be appropriate. Chairman Johnson stated the main portion of the S taff Report was related to the specific user itself. It also mentioned that certain General Industrial uses would not be allowed with the adjacent residential uses. Chairman Johnson stated currently concrete production, mining, landfills, and waste disposal s are zoned GI . H e would argue that adjacent residential properties would not want to have these in their immediate vicinity. He stated their may be an issue with the current GI zoning. The Commission reviewed the proposed Heavy Industrial District zoning classification line by line and made their comments and suggestions. Motion: A motion was made to continue this item until the next Planning Commission meeting. Moved by Commissioner Edwards; Seconded by Commissioner Byrd. Discussion: There was none. Vote: All voted in favor. The motion carried (7-0). V. PRESENTATION: LATEST INFORMATIONAND PRESENTATION OF THE 2020 COMPREHENSIVE PLAN A representative from TSW, Allison Bustin, stated her firm is currently involved in the Comprehensive Plan. She presented the agenda for her presentation: • Meet the Consultants • Process and Schedule • Public Engagement Strategy • Questions She stated TSW are planners, architects and landscape architects and they bring expertise on land use, urban design, and zoning. Ms. Bustin stated also on the team is Arnett Muldrow and they are experts on demographics, housing, and economic development. She stated they w ill be crafting the Economic Development portion of the plan. Lastly , Keck and Wood is also apart of the team. Ms. Bustin stated they are experts in traffic, connectivity, and transportation strategies. Ms. Bustin presented the following schedule: • Research and Analysis – 75% complete Page 4 of 4 • Visioning – Mid September to December 2020 • Draft Recommendations – January to February 2021 • Final Report – March 2021 Ms. Bustin presented all the dates that are currently confirmed: • Stakeholder Interviews – September 10th – 11th • Planning Commission Meeting #2 – October 6th • Public Workshop #1 – Mid October • City Council Meeting (Update) – November 10th • Planning Commission Meeting Public Workshop #2 – January 5th • Draft Plan Open House – Early February • Planning Commission Meeting #4 – TBD • City Council Meeting (Adoption) – March 9th Ms. Bustin presented the Public Engagement Strategy: • Our philosophy is hands on engagement at every step • Flexibility will be key  Our strategies can be done in-person or virtually  If virtual, we will utilize a platform called Social Pinpoint, which can replicate most of the activities conducted at a public workshop  Virtual options would be open for 1-2 weeks VI. DISCUSSION: PARKING REGULATIONS Chairman Johnson stated he proposed minor changes to the parking ordinance with the intent to have more green space. He asked the Commission to review the changes and share their input which will be discussed at the next meeting. VII. COMMENTS FROM THE COMMISSION No comments from the Commission. VIII. COMMENTS FROM STAFF Mr. Brodeur stated he is looking to revise the City ordinance concerning PODs. He stated he a lso met with the consultant last week who is rewriting the sign ordinance. He reminded the Commission that certain members terms are expiring. Chairman Johnson stated a new application procedure is in place to which the Commission will be notified. IX. ADJOURNMENT Commissioner Smith made a motion to adjourn, Commissioner Connerty seconded. All voted in favor (7-0). The meeting adjourned at approximately 7:55pm. ________________________________________ Date: ___________________ Mr. Josh Johnson, Chairman PRESENTATION TSW's Latest Information of the 2020 Comprehensive Plan PRESENTATION Old Back River Road Project/Workshop CITY OF GOOSE CREEK LAND USE APPLICATION TODAY'S DATE: June 22, 2020 PART I. PURPOSE OF SUBMITTAL D Site Plan (See Check/isl) Q Rezoning D Subdivision Plan (See Checklist) D Plat Review D Variance D Conditional Use Permit PART ll. GENERAL INFORMATION I. 2. Development Name: __ P_o_pl_a_r _B_lu_ff ______________________________ _ Street Address: 309 Old Back River Road -------------------------------------- 3. TMS #: 244 00 ---- _ 00 033 / 244-14-05-047, 048 GOOSE CREEK ZoNING DISTRICTS 4. Zoning Classification: � Requested Classification: � (For rezonings only) 5. Total Site Acres: 13.37 CO: Conservation Open Space LI: Light Industrial R-1: Residential Low Density R-2: Residential Medium Density R-3: Residential High Density GC: General Commercial NC: Neighborhood Commercial RC: Restricted Commercial PD: Planned Development PD-MH: PD for Mobile Home PART HJ. CONTACT INFORMATION Owner/Developer Name: Hebe Land, LLC ------------------- ----------------- Street Address: S t City: Telephone: _____ ____ _ Cell Phone: 3 E-mail Address: PART IV. SUBMITTAL INFOR1'1ATION (IF APPLICABLE) St: SC Zip: Fax: _________ _ Proposed Building Use: _S_in....:g::...le_F_a_m_i ly'--R _e_si_d_en_t_ia_l __________________________ _ Proposed Total Building Area (gross sq. ft.): _____ _ Max. Building Height: _3_5'_12_.5 _____ _ Total Number of Buildings/Units/Lots: _+_l_-_63 _____ _ Is The Property Restricted by Any Recorded Covenant Wbich Conflicts With or Prohibits The Proposed Use: no AGENT W AIYER In filing this plan as the property owner, I do hereby agree and firmly bind myself. my heirs, execurors, administrators, successors and assignees jointly and severally to construct all improvements and make all dedications as shown on this proposed site plan as approved by the City of Goose Creek, South Carolina. I hereby designate David Stevens to serve as my agent regarding this application, to receive and respond to administrative comments, to resubmit plans on my behalf. and to represent me in any public meetings regarding this application. Print Name:����·· . . !:4�. , -V�c?!c(J....____ Signature: _ _..,/J=r-=:....£ ........ -'---t}bd_-1--+---�-------------- Date: --'l""-.· �l��z�IW�-1 OLD BUSINESS & PUBLIC HEARING Heavy Industrial District     151.135 HEAVY INDUSTRIAL DISTRICT. (A) Purpose. (1) To develop and reserve areas for heavy industrial uses that involve industrial and intensive manufacturing uses of a larger and more intensive scale, and that may generate substantially more impact on the surrounding properties, such as unenclosed storage, emissions, and noise; and (2) To reserve undeveloped areas suitable for future uses. (B) Permitted uses. The following are approved uses by right. (1) Residential uses. Residential uses which are incidental or accessory to a principal use or to another accessory use or which are for caretakers, security personnel, managers, or other persons whose physical proximity to a principal use or to a principal use or to another accessory use is reasonably required. (Examples of such accessory uses include, but are not limited to, caretaker cottages, temporary guest facilities, on-site residence for supervisory personnel, conference centers, and meeting rooms with overnight accommodations.) (2) Office, governmental, institutional uses, agricultural uses. (a) Any publicly owned and/or operated building, facility or land. (b) Public transportation terminal/passenger facility. (c) Public utility substations, associated gas pipes/lines, transmission lines, distribution lines and any other associated infrastructure. (d) Railroad rights-of-way, excluding all facilities other than those required for track operations. (e) Air monitoring devices. (f) Recreational uses, indoor and outdoor. (g) Agricultural uses, bot h animal and plant and including Timbering operations. (h) Institutional uses such as, colleges, schools, worship, Governmental uses, utilities, and including any utility electric substation infrastructure. (i) Private/public institutional uses such as child and elder care. (i) Office uses as standalone or part of another allowed use. (j) Communication towers. (3) Commercial uses. (a) Animal shelter/kennels (b) Automotive/equipment repair garage offering major repairs, body and fender repairs, and painting.     (c) Commercial, general services. (d) Commercial, transportation (Fleet hub) (truckstop). (e) Emergency medical care facility. (f) Gasoline/fuel sales out let, with or without accompanying convenience store, with pumps/fuel storage tanks set back at least 20 feet from boundaries, and no major repairs or body repairs. (g) Gun range (h) Research or laboratory fa cility, whereby there are no potentially hazardous materials onsite at any time. (i) Storage uses, interior and exterior. Storage uses associated with aluminum production or timbering (j) Vehicle storage (k) Wholesale sales. (4) Commercial industrial uses. (a) Automotive, truck, boat, RV, and/or equipment repair garage offering major repairs, body and fender repairs, and painting, where repairs are made outside the business structure, and/or where damaged vehicles or equipment are stored outside. (b) Automotive towing/storage. (c) Commercial laundry/dry cleaning plant facility. (d) Heavy equipment, machinery, heavy truck sales, service, and repair. (e) Mini warehouses. (f) Storage of recreational vehicles. (5) Light industrial uses. (a) Assembly of products or materials. (b) Distribution center. (c) Parcel services. (d) Production or manufacturing facility, whereby there is no exterior indication of manufacturing. (e) Research facility. (f) Materials handling. (g) Warehousing/distribution. (6) Heavy General industrial uses.     (a) Cold storage plant. (b) Concrete production plant. (c) Freight container storage yard. (d) Fuel storage facility. (e) Light and heavy manufacturing including but not limited to aluminum production/reduction. (f) Manufacturing services (construction and others). (g) Mining/resource extracti on in compliance with DHEC reclamation regulations. (h) Natural resource production (excavation of mineral deposits). (i) Research or stor age facilities, with potentially hazardous or flammable materials. (j) Sanitary landfills. (k) Scrap ya rds, scrap service. (l) Stockpiling of sand , gravel or other materials. (m) Transportation term inal for heavy trucks, commercial freight transfer and distribution center. (n) Waste disposal/r ecycling centers. All commercial waste disposal facilities shall comply with the “Berkeley County and Dorche ster County Solid Waste Management Plan 1993- 2013 and the “Berkeley County Water and Sa nitation Authority 2000 Update to the Solid Waste Management Plan” applicable County solid waste mana gement plan(s). All industrial waste dispos al facilities shall be lined with materials permitt ed by SCDHEC as appropriate for the speci fic waste disposal site. (o) Other necessary and customary uses determined by the Zoning Administrator to be appropriate, incidental and subordinate to the principal use of the property (7) Heavy Industrial Uses (a) Aluminum production, reducti on, smelting and refining facilities (b) Manufacturing services (c) Other necessary and custom ary uses determined by the Zoning Administrator to be appropriate, incidental and subordinate to the principal use of the property. (C) Lot, yard, height and coverage. These requirements are illustrated in Appendix D but are provided here for ease of review. (NOTE: The following standards shall be incorporated into the appropriate Zoning Code Appendices.)     (1.) Minimum lot area: Five acres. (2.) Minimum lot frontage: Two hundred Forty feet (3.) Minimum front yard setback: Fifty Forty feet* (* not applicable to utility poles, public utility substations, fencing and infrastructure elements) (4.) Minimum side yard setbacks : Twenty feet* (* not applicable to utility poles, public utility substations fencing and infrastructure elements) (5.) Minimum rear yard setback : Forty feet* (* not applicable to utility poles, public utility substations, fencing and infrastructure elements) (6.) Minimum second street frontage: Thirty feet (7.) Minimum pervious coverage: Fifty Twenty percent (8.) Maximum building height: Three hundred feet, except that no office space above seventy feet shall be permitted (9.) Chimney/antennas/v ents: Three hundred feet (10.) Church spires/bell to wers/flagpoles: One hundred five feet (11.) Parking Standards: One spac e per TWO employees for the largest shift; plus 25% to allow for shift change overlap (12.) Land Use Buffers: Existing City buffering requirements shall apply, provided that no buffering shall be required for timbering or existing industrial uses unless there is new development or expansion of the existing uses. (D) Accessory uses. Other necessary and customary accessory uses determined by the Zoning Administrator to be appropriate, incidental and subordinate to the principal use of the property. (E) Temporary uses. Other necessary and customary temporary uses determined by the Zoning Administrator to be appropriate, incidental and subordinate to the principal use of the property (F) Conditional uses. As defined in § 151.028, the following uses may be approved uses by a conditional use permit. (1) Cell towers Radio/television station or studio, with transmission tower on premises.   DISCUSSION: Parking Regulations § 151.086 PARKING AND LOADING SPACE. Paved off-street automobile parking shall hereafter be required in all zoning districts at the time of initial construction of any principal building, or when changes in a principal building require more parking. Off-street parking shall have direct access to a street and shall in all respects conform to this chapter. (A) Required space. The minimum number of off-street parking spaces, or loading space, shall be calculated on the basis of land use, or use of the principal building, as specified in Columns 2 and 3 of Appendix A. The number of off-street parking spaces shall not exceed 150 percent of the required minimum number of spaces. For those uses not specifically identified in the annexation, required space shall be determined by the Zoning Administrator. (B) Application of parking requirements. (1) All required parking spaces shall be located on the same lot with the principal building or use, except as provided in division (D) below. (2) In the case of mixed or joint use of a building or lot, the required spaces shall be equal to the sum of the spaces required for each use individually. However, where the peak operating hours of adjoining uses do not overlap, the uses may share up to 50 percent of required parking spaces. (3) Uses not specifically listed in Appendix A shall require parking spaces equal to a listed use of similar parking demand generation, as determined by the Administrator. (4) The total number of spaces required may be reduced up to 10% when the reduction is warranted by unusual circumstances, as determined by the Administrator. (5) The number of employees used for determining parking requirements shall be the average number on the shift of greatest employment. (6) If fractional numbers result from parking space computations, the next highest whole number (as to number of spaces required) shall be used. (C) Area and paving required for parking spaces. Each automobile parking space shall measure nine feet by 18 feet minimum (162 square feet), excluding any aisle or maneuvering space. However, the paved length of a 90-degree parking stall may be reduced to 17 feet, provided that curbing or anchored concrete wheel stops are furnished at the edge of paving to allow the vehicle to overhang the landscape area. Areas in public rights-of-way shall not be used in providing parking or maneuvering space. Curb cuts shall be as specified in § 151.082(F)(2). Parking plans shall be submitted in the form of a scale drawing of the proposed parking and loading spaces, with landscaped areas and demonstrated conformance with these regulations. Approved parking spaces shall be paved. (D) Exceptions to off-street parking areas. Required off-street parking for one and two-family residences shall be located on the same lot as the principal building served. In unusual circumstances or hardships, however, the Commission may approve off-site parking for all other permitted areas, provided the parking area is not more than 300 feet from the principal building or use served, and that the owner of the parking site relinquishes development rights of the property until parking is provided elsewhere. Where the off-site parking is proposed, recorded covenants as to parking use and development rights shall be provided. (E) Joint use off-street parking areas. Two or more principal uses may utilize a common off-street area in compliance with divisions (B)(2) and (D) above. Total spaces required may be reduced by the Commission if a reduction is warranted by the particular grouping of uses. (F) Off-street loading area required. Areas suitable for loading and unloading motor vehicles in off-street locations, and specifically designated for this purpose, shall be required upon initial construction, alteration or conversion of any building intended for commercial, industrial or governmental purposes. The off-street loading area shall have access to a public street and be provided as specified in Appendix A in addition to the preceding off-street parking requirements. (G) Area required per loading space. Each off-street loading space shall be at least 12 feet wide, 40 feet long and 14 feet high, maintained clear of obstructions at all times. (H) Location of off-street loading areas. Off-street loading areas shall be located on the same lot as the structure served, and in no case counted as part of the off-street parking requirements. (I) Adequacy of off-street loading area. Whether specified in this chapter or not, all uses shall provide off-street loading areas sufficient for their requirements that no vehicle being loaded or unloaded shall stand in, nor project into, any public way. (J) Fire lanes required. Commercial or light industrial facilities which have a floor area greater than 7,000 square feet or whose setback is 100 feet or greater from the road right-of-way, are required to establish and maintain fire lanes in compliance with § 3-2 of the State Fire Code. Fire lanes must be a minimum of 20 feet in width and be posted with signs which specifically state “No Parking - Tow Away Zone”. (K) Parking requirements for the disabled person(s). All governmental buildings, public buildings, commercial facilities and places for public uses, including churches and private clubs, with the exception of single-family and two-family residences, shall have parking spaces designated and signs posted in accordance with the following requirements. (1) The international symbol of access to the physically disabled person(s) shall be permanently displayed (marked) on the ground for parking spaces that are reserved for such use. In addition, a sign bearing the international symbol of access to the physically disabled person(s) shall be posted facing each reserved parking space for the disabled person(s). Examples of the signs included one foot by one and one half foot in dimension, with the international symbol and “reserved parking” clearly marked on the sign. (2) Parking spaces shall measure 13 feet by 18 feet minimum (234 square feet), including a five feet minimum access aisle. Parking spaces for the disabled person(s) shall be near main building entrances. Parking spaces and passenger loading zones for the disabled person(s) shall be as follows. (3) Parking spaces and passenger loading zones for the disabled person(s): Total Spaces Or Zones Required Number To Be Reserved For The Disabled Persons(s) 1-25 1 26-50 2 51-75 3 76-100 4 101-150 5 151-200 6 201-300 7 301-400 8 401-500 9 501-1,000 2% of total Over 1,000 20 plus 1 for each 100 over 1,000 One in every eight accessible spaces, but not less than one, shall be served by an access aisle 96 inches (eight feet) wide minimum and shall be designated “van accessible”. APPENDIX A: TABLE OF PARKING AND LOADING SPACE REQUIREMENTS Table of Parking Space Requirements Required Spaces Additional Requirements Residential Single-family dwelling 2 spaces Duplex/two-family dwelling 4 spaces Multi-family dwelling 2 spaces per unit +12% of total for overflow parking Mobile home in mobile home park 2 spaces + 1 space per employee Mobile home park 2 spaces per lot/space + 1 space per employee Rooming/boarding house 1 space per sleeping room + 1 space per 2 employees Group dwelling 1 space per 2 bedrooms Nursing home/sanitarium 1 space per 5 patient beds + 1 space per each 2 employees on largest shift Religious Churches and places of worship 1 space per 5 fixed seats in the main assembly hall Or, 1 space per classroom, whichever is greater Educational Public/private school, trade or business school, or college greater of: 1 space per 4 seats in assembly hall, or 5 spaces per classroom + 1 space per employee Library, museum, art gallery, arts, crafts, or dance studio 10 spaces + 1 space per employee Nursery or pre-school/day-care 1 space per classroom (5 space minimum) + 1 space per employee Places of public assembly 1 space per 100 sq. ft. in main assembly hall Recreational Country club, tennis club, swim club, golf course 1 space per 5 members + 1 space per each 2 employee Private recreation facility 1 space per 5 members + 1 space per employee Club, fraternity, sorority, lodge or union hall 1 space per active member Places of public assembly 1 space per 100 square feet in main assembly hall **Recreation and community center minimum of 1 space per 200 square feet of floor area Office Public or private office building 1 space per 300 square feet of floor area (4 spaces minimum)* Advertising agency, realty office, insurance office 1 space per 300 square feet of floor area (4 spaces minimum)* Radio/television station or studio 1 space per 500 square feet of floor area (4 spaces minimum)* +1 space per employee Commercial Bank, savings and loan assoc. or similar lending institutions 1 space per 200 square feet of floor area * Service or repair establishment, not otherwise mentioned 1 space per 250 square feet of floor area excluding storage * Retail business not otherwise mentioned 1 space per 200 square feet of floor area excluding storage (3 space min.)* + 1 space per employee Theatre, night club, and similar places of assembly 1 space per each 4 seating accommodations + 1 space per each 3 employees on largest shift Automotive repair 1 space per employee + 1 space per each service bay; 10 space minimum*** Motel, hotel, tourist home 1 space per sleeping room or suite + 1 space per each 3 employees Furniture, appliance, equipment, automotive, boat sales and the like 1 space per 300 square feet retail floor area (3 min.) Except that auto sales and service have 10 space min. Bowling alley or center 5 spaces per lane Funeral home or mortuary 1 space per 50 sq. ft. of floor area minus work & storage areas * Planned shopping center 5 spaces per 1,000 sq. ft. of leaseable area * Sit down restaurant 1 space per each 4 seats + 1 space per employee on the largest shift Drive-in restaurant 1 space per 35 sq. ft. of bldg. area * + 1 space per employee on largest shift Take-out restaurant 1 space per 100 sq. ft. of bldg. area * + 1 space per employee on the largest shift Hospital or extended care medical facility 1 space per every 5 patient beds + 1 space per each 2 regular employees on the largest shift Common carrier transportation and/or passenger terminal 1 space per 100 sq. ft. of waiting room (10 space min.) + 1 space per employee on the largest shift Other uses not otherwise specifically mentioned Established by the Zoning Administrator Established by the Zoning Administrator Manufacturing, processing, bulk warehousing, brick/block/coal yard, lumber mill 1 space for each 2 employees on the largest shift (5 spaces minimum) + 1 space for each vehicle operating from the premises Transportation terminal for heavy vehicles, commercial freight distribution and transfer 1 space for each employee (5 spaces minimum) + 1 space for each vehicle operating from the premises *** NOTE: Amended as of March 14, 2017. Ordinance Number 17-005 ** NOTE: Amended as of February 14, 1995. Ordinance Number 95-01 * NOTE: Amended as of March 14, 1995, Ordinance No. 95-02

Source: City of Goose Creek website. First collected Oct 24, 2026.