Agenda
City of Goose Creek · Berkeley County · meeting of Mar 19, 2018 · Agenda packets
Open the original document More from City of Goose Creek
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Architectural Review Board
Monday, March19, 2018
6:30 p.m.
City of Goose Creek
Marguerite H. Brown Municipal Center
519 N. Goose Creek Blvd.
Goose Creek, South Carolina
MEMORANDUM
TO: Members of the Architectural Review Board
FROM: Brenda Moneer
Planning and Zoning Specialist
DATE: March 13, 2018
SUBJECT: Notification of ARB Meeting
This is to inform you that the Architectural Review Board (ARB) will meet Monday,
March 19, 2018,
6:30 p.m. at City Hall. Enclosed please find agenda material for the
meeting.
If you have any questions or comments, please don’t hesitate to contact me at 797 -
6220 ext. 1116, or Kara at ext. 1118. We look forward to seeing you Monday evening.
Please note this Agenda was posted at City Hall and on the City Website prior to meeting.
AGENDA
CITY OF GOOSE CREEK
ARCHITECTURAL REVIEW BOARD MEETING
MONDAY, MARCH 19, 2018 6:30 P.M.
MARGUERITE BROWN MUNICIPAL CENTER
CITY HALL COUNCIL CHAMBERS
519 N. GOOSE CREEK BLVD.
VISION STATEMENT:
Goose Creek is a city that has achieved a balance between growth, the environment, and the preservation of its small town
character. The city’s primary concern is for the lifelong needs of all its citizens. Goose Creek is a partnership between its
government and its people in the determination of the city’s future.
MISSION STATEMENT:
Objectively guide the evolution of commercial and industrial projects creating a synergy between the business and
residential community consistent with the city of Goose Creek’s vision statement.
THE PROCEDURE FOR PARTICIPATION WILL BE AS FOLLOWS:
Minor applications will be allotted three (3) minutes to present to the Board, major applications will be allotted five (5)
minutes to present. Board members will be allowed to ask questions and to discuss merits of the application following the
presentations. The question/discussion period by the Board will be limited to five (5) minutes for minor applications and ten
(10) minutes for major applications.
AGENDA:
I. Call to Order – Chairperson Sharon Clopton
II. Review of Minutes from February 19, 2018
III. Old Business – Major Applications
A. Popeyes – Elevations, Colors, Materials
B. E-Z Auto Now – Site, Landscaping, Elevations, Colors, Materials
IV. Comments from Board
V. Comments from Staff
VI. Adjournment
MINUTES
CITY OF GOOSE CREEK
ARCHITECTURAL REVIEW BOARD MEETING
MONDAY, FEBRUARY 19, 2018, 6:30 P.M.
MARGUERITE H. BROWN MUNICIPAL CENTER
519 N. GOOSE CREEK BOULEVARD
I. Call to Order – Chairperson, Sharon Clopton
Motion: at 6:28 pm, Action: Called Meeting to Order, Moved by Sharon Clopton
Roll Call.
Present: Joel Arenson, Gary Beck er, David Cantrill, Sharon Clopton, Tom Risso.
Absent: Lisa Burdick
Staff Present: Kara Browder, Brenda Moneer
II. Review of Minutes from December 18, 2017, and January 16, 2018
Motion: Approve the minutes as presented., Moved by Joel Arenson,
Seconded by Gary Becker.
Discussion: There was none.
Vote: All voted in favor. ( summary: Yes = 5).
III. Old Business – Minor Applications
A. CiCis – Wall Mount Sign
The applicant was not present.
B. Splash‐N‐Dash Vacuum Systems
The applicant presented the revised application to the Board. He mentioned the color of the
hoses would be changed to black, and the stantions would also b e b l a c k . T h e a p p l i c a n t
mentioned the coin vacuums would remain per the owner. Chairperson Clopton inquired to the
applicant if the new system would consist of ten vacuuming arch es. The applicant confirmed it
would, and stated the design would still be installed at an angle as shown in the submittal.
Chairperson Clopton inquired if the vacuums would have a cover over them. The applicant stated
no. There was discussion about the recoating of the equipment with a satin black.
Motion: Approve the application as submitted contingent upon the arch es and
hoses to be a black and satin color., Moved by Joel Arenson,
Seconded by Gary Becker.
Discussion: Chairperson Clopton inquired about the location and color of the collection
container. The applicant stated that it would be located at th e front left
corner of the property, and is a chrome color. Mr. Arenson inquired if each
arch had individual pumps. The applicant stated it would all be contained
in the one vacuum pump. The applicant also noted they could provide
landscaping around the pump area along Red Bank Road if needed, and
presented a landscaping plan. There was discussion about the types of
shrubs to be used for screening. Mr. Cantrill inquired about t he height of
the pump. The applicant stated it is approximately 3’ x 3’ x 5’ tall.
Vote: All voted in favor. ( summary: Yes = 5).
A. CiCis – Wall Mount Sign and Tenant Panel
The applicant presented the application to the Board with the modifications to the tenant panel.
Chairperson Clopton inquired to the applicant if the building s ignage had been installed, and if
the tenant panel would match the façade signage. The applicant stated that was correct. Mr.
Becker inquired if the background would be red as submitted. The applicant answered yes. There
was a brief discussion about the condition of the building. Th ere was also discussion about the
modified tenant panel not matching the façade signage. Staff mentioned that the applicant and
the owner was informed that the Board would like to see both signs match. The applicant
presented alternate options. The Board discussed and chose Alternative “A”.
Motion: Approve the application as submitted with the application mod ification of
the alternative “A” tenant panel., Moved by David Cantrill, Seconded by
Gary Becker.
Discussion: There was none .
Vote: All voted in favor. ( summary: Yes = 5).
C. American Heritage Ambulance ‐ Signage
The representative presented the application to the Board. The re was a brief discussion about
the location of the proposed and previous signage. Staff noted the applicant had amended the
application for the freestanding sign to meet the ordinance cri teria. Chairperson Clopton
inquired about the frame on the building sign. The applicant stated black. It was confirmed this
would remain black. There was discussion about the road signag e colors, and the panel on the
building to be replaced. Mr. Cantrill inquired if it was lit. The applicant stated no. Chairperson
Clopton asked if the road signage was dual sided. There was a detailed discussion about the road
sign base, landscaping and color, lettering font to be a navy color and matching on both the
building and road signage.
Motion: Approve the application as submitted with the stipulation tha t the font and
color of the lettering match on the building and road signage w hich is a
dark blue., Moved by Joel Arenson, Seconded by Gary Becker.
Discussion: There was none.
V o t e : All voted in favor. ( summary: Yes = 5).
D. All State Insurance – Signage
The representative presented the application to the Board. The re was discussion regarding the
criteria for maximum allowable tenant panels. Staff stated that the tenant panels are within the
size of the shopping center signage
Motion: Approve the application as submitted for the wall mounted sig n., Moved
by Joel Arenson, Seconded by Tom Risso.
Discussion: Mr. Cantrill suggested the tenant panel be white with blue in keeping with
the practice of matching the tenant panel and wall mount sign.
Motion: Mr. Arenson amended his motion to add the stipulation that the tenant
panel consist of a white panel with blue lettering, Seconded by Tom Risso
V o t e : All voted in favor. ( summary: Yes = 5).
E. State Farm – Signage
The representative presented the a p p l i c a t i o n t o t h e B o a r d . C h airperson Clopton verified the
tenant panel would be white with red lettering. The applicant agreed it would.
Motion: Approve the application as submitted for the wall mounted sig n., Moved
by Tom Risso, Seconded by David Cantrill.
Discussion: There was none.
V o t e : All voted in favor. ( summary: Yes = 5).
F. MoMo ‐ Signage
The representative presented the application to the Board. Cha irperson Clopton inquired if the
a w n i n g s w e r e e x i s t i n g . T h e a p p l i c a n t s t a t e d y e s . T h e r e w a s d iscussion about the type of
business.
Motion: Approve the application as submitted for the wall mounted sig n., Moved
by Tom Risso, Seconded by Joel Arenson.
Discussion: Chairperson Clopton inquired if the previous signage was still there, and
inquired about the condition of the façade of the building. Th e applicant
stated he thought it was gone. The applicant stated he would relay that to
the business.
Motion: Mr. Risso amended his motion contingent upon refurbishing the raceway
as necessary. The applicant stat ed he would relay to the busin ess. Mr.
Arneson seconded the amended motion.
Discussion: Mr. Cantrill inquired about the height of the signage. The ap plicant stated
it would be installed as shown in the proposal.
V o t e : All voted in favor. ( summary: Yes = 5).
G. Pet Rest – Front Elevation Modifications
The representative presented the application, material and colo r samples to the Board. There
was discussion about the scope of work, included the materials specifications and colors to match
the existing. The applicant added the colors would match the existing.
Motion: Approve the application as submitted for the wall mounted sig n., Moved
by Tom Risso, Seconded by David Cantrill.
Discussion: There was none.
V o t e : All voted in favor. ( summary: Yes = 5).
IV. New Business – Major Applications
H. Popeyes – Site, Landscaping, Elevations, Colors and Materials
Mr. David Banks presented the application to include the site, landscaping, elevations, colors and
materials to the Board. There was discussion about the current building demo. Mr. Banks stated
t h a t t h e l a n d s c a p i n g w a s a l t e r e d a b i t d u e t o t h e p o w e r l i n e s that run diagonally across the
property. He added the signage would come later. Chairperson Clopton inquired about buffers.
Staff added with like uses a buffer would not be required becau se of the like zoning at the side
and rear. There was discussion about the fencing on the adjacent property. Mr. Arenson inquired
about the HVAC system location, and the dumpster enclosure. Mr. Banks stated the HVAC would
be a roof top system and the dumpster enclosure would match the building. There was a lengthy
discussion about the colors as proposed, and the drive‐thru location. Chairperson Clopton stated
concern for the yellow beige color.
Motion: Approve the application as submitted., Moved by Joel Arenson, Seconded
by Tom Risso.
Discussion: Mr. Cantrill asked for clarification on the green accents. The representative
stated they were a fixed shutter. Staff pointed out the render ing did not
show the roof top equipment completely screened. The applicant stated
the plans did address that, however, they had not incorporated that into
the color rendering. The Board requested the spacing be a more e q u a l
space between each shutter. Mr. Becker asked if they could propose a
different color in lieu of the gold.
Vote: Chairperson Clopton requested a roll call vote. Joel Arenson , No; Gary
Becker, No; David Cantrill, No; Sharon Clopton, No; Tom Risso, Yes. Motion
Failed. (summary: Yes = 1; No 4).
Discussion: Chairperson Clopton requested that the applicant bring back th e
application with an alternate color scheme. Mr. Banks asked th e Board if
they would consider approval of site and landscaping, and review colors at
a future date.
Motion: Approve the application as submitted minus the color scheme, a nd revisit
the colors at a later date. Moved by Tom Risso, Seconded by D a v i d
Cantrill.
Vote: All voted in favor. ( summary: Yes = 5).
I. E‐Z Auto Now – Site, Landscaping, Elevations, Colors and Materials
Ms. Ashley Blauser‐Silva presented the application to include t he site, landscaping, floorplans,
elevations, colors, and materials to the Board. She detailed the location on Red Bank Road. There
was a lengthy discussion about the landscaping, lighting, and lack of architectural interest in the
elevations. There was additional discussion about the signage, fencing, landscaping buffer,
easements and setbacks. Chairperson Clopton stated concern for t h e e l e v a t i o n s , a n d l a c k o f
architectural interest with materials or color. The applicant stated she was looking for a clean
look, and proposed an awning over the entry doors.
Motion: Approve the application as submitted., Moved by Tom Risso, Seconded by
Joel Arenson.
Discussion: T h e r e w e r e s u g g e s t i o n s t o a d d s o m e a r c h i t e c t u r a l f e a t u r e s t o the
elevations.
Vote: Chairperson Clopton requested a roll call vote. Joel Arenson , No; Gary
Becker, No; David Cantrill, No; Sharon Clopton, No; Tom Risso, Yes. Motion
Failed. (summary: Yes = 1; No 4).
J. Walmart ‐ Elevations, Colors and Signage
Mr. Chris Carlson presented the application to include the elev ations, colors and signage to the
Board, along with color samples. There was discussion about th e modifications to the signage
proposal to meet the sign ordinance regulations. The Board sta ted concern for the use of the
orange on the entire corner. Mr. Carlson stated he could box an area of orange behind the “pick‐
up” signage. The Board stated favor for that modification. There was discussion about the
quantity of signage on the front elevation, and the sides to meet the zoning ordinance. Staff also
mentioned the square footage exceeded the maximum allowance, ho wever if the calculations
were per channel letter, they would meet the requirements. Mr. Cantrill inquired about the tree
l o c a t e d i n f r o n t o f t h e P l a n t a t i o n N o r t h C o r n e r . M r . C a r l s o n stated they would propose to
relocate the tree and freshen up the landscaping in that corner. The applicant detailed the colors
with the color samples.
Motion: Approve the application as submitted with the stipulation tha t the orange
be limited to a box around the pick‐up sign rather than the ent ire corner
portion of the facade., Moved by Tom Risso, Seconded by Joel Arenson.
Discussion: There was none.
V o t e : All voted in favor. ( summary: Yes = 5).
V. Comments from the Board
Chairperson Clopton mentioned the shopping center signage on Red Bank Road still did not have
the landscaping installed as per the approval. She also mentioned the Mattress Firm was using a
waving balloon on weekends, and that there was a banner with permanent wording information
located at the First Baptist Church that needed Staff to check into. She mentioned it was hanging
over their LED sign. Chairperson Clopton inquired to staff about the number of shopping center
signage for the Crowfield Village. Staff stated they would add ress this with the owners.
C h a i r p e r s o n C l o p t o n i n f o r m e d s t a f f t h a t t h e M e x i c a n T e q u i l e r i a had been painted a different
color with no ARB review. Mr. Cantrill inquired about the Star bucks. Staff noted the applicant
was approved to remove the asbestos from DHEC, however they are waiting on Corporate. There
was a brief discussion about the pumps at the Time to Shine, an d how Staff is currently working
with the owner to resolve the screening issue around the pumps.
VI. Comments from Staff
Ms. Browder had no additional comments.
VII. Adjournment
Motion: Motion to adjourn at 8:16 pm., Action: A d j o u r n , Moved by Tom Risso,
Seconded by Joel Arenson.
Discussion: There was none.
Vote: All voted in favor. ( summary: Yes = 5).
________________________________________ Date_____________________________
Sharon Clopton, Chairperson
Page 1 of 1
ARCHITECTURAL REVIEW BOARD: SCOPE OF WORK
P
ROJECT: Popeyes
L
OCATION: 135 St James Ave
This commercial development is located on the corner lot at St. James Ave. and Etling Ave.
where the Berchador was located years ago.
The applicant will be presenting plans to build a Popeyes sitdown restaurant with drive thru.
The applicant has been working in conjunction with SCDOT to configure the access/egress for
this property as shown on the civil plans submitted to Planning.
Site – Street View – Existing Berchador Building
provided by Google™ “ street view January 2017 ”
1.0 SUBMITTALS
SPECIFICATIONS:
DIVISION 7: THERMAL AND MOISTURE
PROTECTION
SECTION 7C: SHEET METAL WORKGENERAL
PROVISION
1. SCOPE: FURNISH AND INSTALL GRAVEL STOPS, FLASHING, PARAPET CAP,
DOWNSPOUTS, AND GUTTERS.
A. ROOFING MEMBRANE FLASHING IS INCLUDED IN SECTION
7B: MEMBRANE ROOFING.
MATERIALS
1. MATERIALS SHEET METAL: .032 ALUMINUM.
2. NAIL FASTENERS: 1 3/4" X 11 GAUGE GALVANIZED, STAINLESS STEEL, OR
ALUMINUM ROOFING NAILS MAY BE USED FOR FASTENERS INTO WOOD WHEN
CONCEALED ONLY.
3. WASHERS: NEOPRENE
4. SCREW FASTENERS: CORROSION-RESISTANT, SELF-TAPPING, HEX HEAD
SCREW, 1/4" MINIMUM DIAMETER WITH SUFFICIENT LENGTH TO PENETRATE 1"
MINIMUM INTO WOOD OR 1/2" MINIMUM INTO STEEL. PROVIDE NEOPRENE
SEALING WASHER FOR EXPOSED FASTENING.
PERFORMANCE
1. INSTALLATION: EXPOSED FLASHINGS SHALL BE PAINTED TO MATCH
ADJACENT MATERIALS. VERIFY WITH POPEYES' REPRESENTATIVE.
SECTION 7D: STANDING SEAM
CANOPYPART 1 - GENERAL
A. SUBMIT FOR APPROVAL SAMPLES, SHOP DRAWINGS,
PRODUCT DATA.
QUALITY ASSURANCE
A. COMPLY WITH GOVERNING CODES AND REGULATIONS.
PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS
WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE
FOR THREE YEARS. USE EXPERIENCED INSTALLERS.
DELIVER, HANDLE, STORE MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.WARRANTY
METAL ROOF SYSTEM MANUFACTURER, UPON FINAL
ACCEPTANCE FOR PROJECT, FURNISH A WARRANTY
COVERING BARE METAL AGAINST RUPTURE, STRUCTURAL
FAILURE AND PERFORATION DUE TO NORMAL ATMOSPHERIC
CORROSION EXPOSURE FOR A PERIOD OF 20 YEARS.
PART 2 - PRODUCTS (UC-4 SERIES, AS MANUFACTURED AND SPECIFIED BY
UNA-CLAD., METAL ROOF SYSTEMS.)
2.0 MATERIALS
A. METAL ROOF SYSTEM PROFILE:
1. UC-4 "NO CLIP", 1 1/2" HIGH BATTENS x 12" RIB TO RIB.
(SMALL BATTEN-SB)
2. CONCEALED FASTENER
B. GAUGE:
1. .026 GAUGE - STEEL
C. TEXTURE:
1. SMOOTH.
D. FINISH:
1. PREMIUM FLUOROCARBON COATING PRODUCED WITH
KYNAR 500 OR HYLAR 5000 RESIN (20 YEAR WARRANTY.)
E. MANUFACTURER:
1. UNA-CLAD OR EQUAL.
PART 3 - EXECUTION
3.0 INSTALLATION
A. COMPLY WITH SMACNA SHEET METAL MANUAL
RECOMMENDATIONS. COMPLY WITH ACCESSORY
MANUFACTURERS' INSTRUCTIONS AND RECOMMENDATIONS.
COORDINATE INSTALLATION WITH ROOFING SYSTEM TO
ENSURE WEATHERTIGHT PERFORMANCE.
B. ANCHOR SECURELY TO STRUCTURE TO WITHSTAND
INWARD AND OUTWARD LOADS.
C. ISOLATE DISSIMILAR METALS TO PREVENT GALVANIC
CORROSION.
DIVISION 9: FINISHES
SECTION 9G: EIFS
PART 1 GENERAL
1.01 DESCRIPTION
A. DESIGN REQUIREMENTS: THE STRUCTURAL WALL SYSTEM
TO WHICH THE EIFS IS ATTACHED SHALL MEET L/240 MAXIMUM
ALLOWABLE DEFLECTION CRITERIA AND APPLICABLE BUILDING
CODE REQUIREMENTS.
1.02 SUBMITTALS
A. SUBMIT SAMPLES FOR APPROVAL AS DIRECTED BY
OWNER.
1.03 DELIVERY, STORAGE AND
HANDLING
A. ALL EIFS MATERIALS SHALL BE DELIVERED IN THEIR
ORIGINAL SEALED CONTAINERS BEARING MANUFACTURER'S
NAME AND IDENTIFICATION OF PRODUCT WITH WRITTEN
APPLICATION INSTRUCTIONS AND APPROPRIATE HEALTH,
HAZARD, AND SAFETY DATA.
B. ALL EIFS READY-MIXED MATERIALS SHALL BE PROTECTED
FROM EXTREME HEAT, SUN AND FROST. FACTORY
PROPORTIONED BAGGED MATERIALS SHALL BE STORED OFF
THE GROUND AND PROTECTED FROM MOISTURE.
1.04 JOB CONDITIONS
A. ALL EIFS MATERIALS SHALL NEVER BE APPLIED IF AMBIENT
AND SURFACE TEMPERATURES CANNOT BE KEPT ABOVE 40° F
DURING APPLICATION AND DRYING PERIOD. FOR
INSTALLATION IN TEMPERATURES LESS THAN 40° F
SUPPLEMENTARY HEAT SHALL BE PROVIDED. THE INSTALLED
EIFS MATERIALS SHALL BE PROTECTED FROM EXPOSURE TO
RAIN AND FREEZING UNTIL DRY.
C. AFTER SATISFACTORY INSPECTION OF SURFACES AND
CORRECTION OF ANY DEVIATIONS FROM SPECIFICATION
REQUIREMENTS, THE EIFS INSTALLATION MAY BEGIN PER
MANUFACTURER'S INSTRUCTIONS.
D. THE STARTER STRIP OF MESH SHALL BE WIDE ENOUGH TO
ADHERE 4" OF MESH ONTO THE WALL, BE ABLE TO WRAP AROUND THE
BOARD EDGE AND COVER APPROXIMATELY 4" ON THE OUTSIDE
SURFACE OF THE BOARD. THIS "BACKWRAP" PROCEDURE SHALL BE
FOLLOWED AT ALL EXPOSED BOARD EDGES IN ACCORDANCE WITH
DETAILS (EXAMPLE-WINDOW AND DOOR HEADS AND JAMBS).
ALL AREAS WHERE THE EIFS MEETS DISSIMILAR MATERIAL OR
TERMINATES (FOR EXAMPLE, WINDOW AND DOOR FRAMES) SHALL
HAVE THE INSULATION BOARD CUT BACK FROM THE ADJOINING
MATERIAL A MINIMUM OF 1/4" TO FORM AN ISOLATION JOINT.
E. APPLY THE ADHESIVE TO THE BACK OF THE INSULATION BOARD.
STAGGER VERTICAL JOINTS AND INTERLOCK BOARDS AT ALL INSIDE
AND OUTSIDE CORNERS. APPLY FIRM PRESSURE OVER ENTIRE
SURFACE OF THE BOARDS TO INSURE UNIFORM CONTACT. BOARDS
SHALL BRIDGE SHEATHING JOINTS BY A MINIMUM OF 8". ALL BOARD
JOINTS SHALL BE BUTTED TIGHTLY TOGETHER TO ELIMINATE ANY
THERMAL BREAKS IN THE EIFS. CARE MUST BE TAKEN TO PREVENT
ANY ADHESIVE FROM GETTING BETWEEN THE JOINTS OF THE
BOARDS. ALL OPEN JOINTS IN THE INSULATION BOARD LAYER SHALL
BE FILLED WITH SLIVERS OF INSULATION OR AN APPROVED SPRAY
FOAM.
F. NAILS, SCREWS, OR ANY OTHER TYPE OF NONTHERMAL
MECHANICAL FASTENER SHALL NOT BE USED.
G. EXPANSION JOINTS ARE REQUIRED IN THE EIFS WHERE THEY
EXIST IN THE SUBSTRATE, WHERE THE EIFS ADJOINS DISSIMILAR
CONSTRUCTION, AND AT FLOOR LINES IN MULTILEVEL WOOD FRAME
CONSTRUCTION. THE EIFS SHALL TERMINATE AT THE EXPANSION
JOINT TO PROVIDE APPROPRIATE JOINT SIZE (SEE DETAILS) AND ALL
BOARD EDGES SHALL BE COATED WITH APPROPRIATE GROUND COAT
AND MESH IN ACCORDANCE WITH STANDARD "BACKWRAPPING"
PROCEDURE. APPROPRIATE SEALANT/PRIMER AND BACKER SHALL BE
INSTALLED AFTER GROUND COAT IS FULLY DRY TO PREVENT ANY
WATER FORM GETTING INTO OR BEHIND THE SYSTEM.
H. USE OF PLASTIC OR METAL CORNER BEADS, STOPBEADS, ETC., IS
FORBIDDEN.
I. APPLY APPROPRIATE GROUND COAT OVER THE INSULATION BOARD
WITH PROPER SPRAY EQUIPMENT OR A STAINLESS STEEL TROWEL TO
A UNIFORM THICKNESS OF APPROXIMATELY 1/16". WORK
HORIZONTALLY OR VERTICALLY IN STRIPS OF 40", AND IMMEDIATELY
EMBED STANDARD REINFORCING MESH INTO THE WET GROUND COAT.
THE MESH SHALL BE DOUBLE WRAPPED AT ALL CORNERS AND
OVERLAPPED NOT LESS THAN 2-1/2" AT MESH JOINTS.AVOID
WRINKLES IN THE MESH. THE FINISH THICKNESS OF THE GROUND
COAT SHALL BE SUCH THAT THE MESH IS FULLY EMBEDDED. ALLOW
GROUND COAT TO THOROUGHLY DRY BEFORE APPLYING PRIMER OR
FINISH.
J. DUPLICATE INSTALLATION PROCESS NOTED IN 3.01 M USING
STANDARD MESH CREATING SECOND MESH LAYER AND ADDITIONAL
IMPACT RESISTANCE. ALLOW TO DRY BEFORE APPLICATION OF
EITHER STO PRIMER (OPTIONAL) OR STO FINISH.
K. IF A PRIMER IS USED, APPLY WITH BRUSH, ROLLER OR PROPER
SPRAY EQUIPMENT OVER CLEAN, DRY GROUND COAT AND ALLOW TO
DRY THOROUGHLY BEFORE APPLYING FINISH. P. APPLY FINISH
DIRECTLY OVER THE GROUND COAT (OR PRIMED GROUND COAT)
ONLY AFTER THE GROUND COAT/PRIMER HAS THOROUGHLY DRIED.
THE FINISH SHALL BE APPLIED BY SPRAYING, ROLLING OR TROWELING
WITH A STAINLESS STEEL TROWEL, DEPENDING ON FINISH SPECIFIED.
GENERAL RULES FOR APPLICATION OF FINISHES ARE AS FOLLOWS:
1. USE A CLEAN, RUST-FREE, HIGH-SPEED MIXER TO
THOROUGHLY STIR THE FINISH TO A UNIFORM CONSISTENCY
(SMALL AMOUNTS OF CLEAN WATER MAY BE ADDED TO AID
WORKABILITY).
2. AVOID APPLICATION IN DIRECT SUNLIGHT.
3. APPLY FINISH IN A CONTINUOUS APPLICATION, ALWAYS
WORKING TO A WET EDGE.
4. WEATHER CONDITIONS AFFECT APPLICATION AND DRYING
TIME. HOT OR DRY CONDITIONS LIMIT WORKING TIME AND
ACCELERATE DRYING AND MAY REQUIRE ADJUSTMENTS IN
THE SCHEDULING OF WORK TO ACHIEVE DESIRED RESULTS;
COOL OR DAMP CONDITIONS EXTEND WORKING TIME AND
RETARD DRYING AND MAY REQUIRE ADDED MEASURES OF
PROTECTION AGAINST WIND, DUST, DIRT, RAIN AND FREEZING.
5. AESTHETIC "U"-GROOVES MAY BE DESIGNED INTO THE
SYSTEM. (A MINIMUM OF 3/4" INSULATION BOARD MUST BE
LEFT AFTER ANY GROOVES ARE CUT).
6. "R" (RILLED TEXTURE) FINISHES MUST BE FLOATED WITH A
PLASTIC TROWEL TO ACHIEVE THEIR RILLED TEXTURE.
7. AVOID INSTALLING SEPARATE BATCHES OF FINISH
SIDE-BY-SIDE.
8 . APPLY FINISH COLOR TO EIFS MIX AND APPLY TO WALL.
COLOR TO MATCH EXTERIOR FINISH SCHEDULE COLORS.
ELEC. C.T. CABINET,
(VERIFY W/ LOCAL CODE
THE REQ'D. LOCATION
& MOUNTING HEIGHT)
WALL PACK
LIGHT FIXTURE
L. STO EXTERIOR INSULATION AND FINISH TEXTURE SYSTEM: APPLY
HIGH IMPACT SYSTEM ADJACENT TO DOORS FOR ADDITIONAL IMPACT
RESISTANCE, USING STO INTERMEDIATE MESH. USE THE STANDARD
SYSTEM SPECIFICATIONS AT ALL OTHER LOCATIONS.
A. PROVIDE MANUFACTURERE'S STANDARD LABOR AND
MATERIAL WARRANTY.
1.11 WARRANTY
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. STO CORP.
B. DRYVIT SYSTEMS, INC.
2.02 ADHESIVES
A. DISPERSION ADHESIVE - NONCEMENTITIOUS, ACRYLIC
BASED ADHESIVE.
A. NOMINAL 1.0 lb/cubic feet (16 kg/cubic meter) EXPANDED
POLYSTYRENE (EPS) INSULATION BOARD IN COMPLIANCE WITH
ASTM C 578 TYPE I REQUIREMENTS, AND EIMA GUIDELINE
SPECIFICATION FOR EXPANDED POLYSTYRENE (EPS)
INSULATION BOARD.
2.03 INSULATION BOARD
2.04 BASECOAT
A. ONE-COMPONENT POLYMER MODIFIED CEMENTITIOUS
BASE COAT WITH FIBER REINFORCEMENT AND LESS THAN 33%
PORTLAND CEMENT CONTENT BY WEIGHT.
2.05 REINFORCING MESHES
A. STANDARD MESH
1. STO MESH - NOMINAL 4.5 oz/sq.yd. (163 g/sq.meter),
SYMMETRICAL, INTERLACED OPEN-WEAVE GLASS FIBER
FABRIC MADE WITH MINIMUM 25 PERCENT BY WEIGHT
ALKALINE RESISTANT COATING FOR COMPATIBILITY WITH STO
MATERIALS.
B. HIGH IMPACT MESH
1. STO INTERMEDIATE MESH (MESH C) - NOMINAL 11.0
oz/sq.yd. HIGH IMPACT, INTERWOVEN, OPEN WEAVE GLASS
FIBER FABRIC WITH ALKALINE RESISTANT COATING FOR
COMPATIBILITY WITH STO MATERIALS.
2.06 PRIMER
A. STO PRIMER
ACRYLIC BASED PRIMER (FOR STO ACRYLIC BASED
FINISHES)
B. WATER: CLEAN AND POTABLE.
2.08 JOB MIXED INGREDIENTS
A. PORTLAND CEMENT: ASTM C 150, TYPE I.
A. STO ACRYLIC BASED TEXTURED WALL COATING. SEE
E.I.F.S. FORMULAS FOR FINISH COLOR.
2.07 FINISH COAT
2. CONCRETE, MASONRY OR PLASTER SURFACES SHALL BE
PROPERLY CURED AND FREE OF DIRT, DUST, OIL, GREASE,
MILDEW, FUNGUS, LATENCY, PAINT, EFFLORESCENCE AND
ANY OTHER CONTAMINANT. ANY SURFACES NOT IN
COMPLIANCE SHALL BE CORRECTED PER MANUFACT.
RECOMMENDATIONS PRIOR TO INSTALLATION OF THE EIFS.
1. PLYWOOD SHEATHING SHALL MEET A.P.A. (AMERICAN
PLYWOOD ASSOCIATION) REQUIREMENTS FOR EXTERIOR OR
EXPOSURE 1 CLASSIFICATION. APA DESIGN AND
CONSTRUCTION GUIDELINES SHALL BE FOLLOWED FOR
STORAGE, HANDLING AND INSTALLATION. MANUFACTURER'S
PUBLISHED RECOMMENDATIONS SHALL BE FOLLOWED FOR
SHALL BE FOLLOWED FOR STORAGE, HANDLING, STORAGE,
HANDLING, INSTALLATION AND PROTECTION. ANY SHEATHING
NOT IN COMPLIANCE SHALL BE REPLACED TO CONFORM WITH
SPECIFICATION REQUIREMENTS PRIOR TO INSTALLATION OF
THE EIFS.
B. THE SURFACE TO RECEIVE THE EIFS SHALL BE STRUCTURALLY
SOUND, CLEAN, DRY AND FREE OF WARPAGE, RESIDUAL MOISTURE
OR DAMAGE FROM MOISTURE. SURFACES SHALL BE UNIFORM, WITH
NO IRREGULARITIES GREATER THAN 1/8" in 4'-0". SURFACES SHALL BE
INSPECTED FOR COMPLIANCE WITH THE FOLLOWING REQUIREMENTS
PRIOR TO INSTALLATION OF THE EIFS:
A. UNDER NO CIRCUMSTANCES SHALL ANY OF THE PRODUCTS BE
ALTERED BY ADDING ANY ADDITIVES, EXCEPT FOR SMALL AMOUNTS
OF CLEAN WATER AS DIRECTED ON LABEL. ANTIFREEZE,
ACCELERATORS, RAPID BINDERS, ETC., ARE FORBIDDEN.
PART 3 EXECUTION
EP-7
EP-2
EP-1
ACCENT BAND
SW-1
EP-2
EP-1
ACCENT BAND
SW-1
EP-2
EP-2
EP-2
EP-2
EP-3 EP-3
EP-3
FINISHED FLOOR
0'-0" AFF.
T.O. PARAPET
16'-8" AFF
T.O. PARAPET
19'-4" AFF
7'-8"
6'-4"
8'-4"
J-BOX FOR
OPTIONAL SIGN
LADDER, PAINT
BRONZETONE
TO MATCH STORE FRONT
EP-1
GREASE & C02
ENCLOSURE BY
VENDOR
INSULATED GREASE
REMOVAL PIPE
3'-6" 6'-0"
T.O. WINDOW
6'-2" AFF
B.O. BALCONY
9'-4" AFF
T.O. PARAPET
18'-0" AFF.
PROVIDE QUICK
COUPLE HOSE
CONNECTOR &
DRAIN VALVE AT
FRYERS. RUN
SELF-DRAINING PIPE
FROM FRYERS TO
OUTSIDE
COLLECTION UNIT.
AWNING SUPPORTS AT
4'-0" O.C. AND AT EACH
END
EP-2
EP-2
EP-2
EP-2
SW-1
EP-1
EP-1
EP-2
EP-1
EP-1
SW-1
SW-1
FINISHED FLOOR
0'-0" AFF.
B.O. AWNING
9'-4" AFF
T.O. PARAPET
16'-8" AFF
T.O. PARAPET
19'-4" AFF
C-1
2'-10"
EP-7
ACCENT BAND
T.O. PARAPET
18'-0" AFF.
EP-1
C-1
TOTAL OF 3 EQ.
WINDOWS W/
MULLIONS
EP-8
EP-1 EP-1
11"
5'-0" 5'-0"
C-1
EP-10
EP-6
(2) DOUBLE LOUVER
VINYL SHUTTER
1" SPACE GAP
E.I.F.S. WALL TEXTURE FINISH STO COLORS
Manuf. Texture NA10-0036 - DELIGHTFUL GOLDEN
STO STO ESSENCE SWIRL
for GOLDEN, BROWN COLOR
NA10-0038 - EXOTIC RED
DRYVIT QUARTZ PUTZ
NA10-0037 - MOCHA BROWN
FINISH NOTES DRYVIT COLORS
POPE051020 - DELIGHTFUL GOLDEN
POPE021028S - EXOTIC RED
POPE031020S - MOCHA BROWN* STANDING SEAM ROOF
* D/T WINDOW CANOPY RAILING
* CLEARANCE BAR
* MENU CANOPY
* GUARD RAIL
* AWNINGS
* SHUTTERS
THE FOLLOWING COMPONENTS CAN BE
PURCHASED FROM THE APPROVED SIGN
VENDORS:
EXTERIOR FINISH NOTES
STO STOLIT 130D, FINE SAND
for RED COLOR
EIFS FRAME,
PAINTED EP-1
WALL MOUNTED SIGN AND FRAMING
AS SHOWN: IL-27 ILLUMINATED
LETTERS BUILDING SIGN
COORD. W/ CIVIL
DRAWINGS FOR
CONTINUATION
COORD. W/ CIVIL
DRAWINGS FOR
CONTINUATION
A5
1
A5
2
A5
3
A5
SECTION 8A: ALUMINUM ENTRANCE, STOREFRONT
MATERIALS
SECTION 8D: GLAZING
MATERIALS
PERFORMANCE
GENERAL PROVISIONS
SPECIFICATIONS
GENERAL PROVISIONS
SCOPE: FURNISH AND INSTALL THE ALUMINUM ENTRANCE AND
STOREFRONT SYSTEMS PER NATIONAL ACCOUNTS AND APPLICABLE
DRAWINGS.
1. ALUMINUM STOREFRONT AND ENTRANCE FRAMES: REFER TO
CONSTRUCTION DRAWINGS AND SPECIFICATIONS.
2. ALUMINUM ENTRANCE DOORS: REFER TO CONSTRUCTION DRAWINGS AND
SPECIFICATIONS.
3. PANIC HARDWARE:WHEN PANIC HARDWARE IS REQUIRED ON EXTERIOR
DOORS.
THE PANIC DEVICE IS ON EXTERIOR ENTRY DOORS WHEN SPECIFIED IN
HARDWARE SCHEDULE.
4. DRIVE-THRU SERVICE WINDOW: THE DRIVE-THRU SERVICE WINDOW WILL BE
SUPPLIED & INSTALLED BY G.C. VERIFY EXACT TYPE OF WINDOW WITH PLANS.
BRONZE FINISH.
WINDOW TO BE:
A. BASE BID - 'QUICK SERV' M.C.E. WINDOW FLUSH MOUNT.
B. OPTION (VERIFY WITH OWNER) - READY ACCESS
5. MISCELLANEOUS FLASHING/TRIM: ALUMINUM HEAD, SILL, COLUMN AND
WALL TRIM. SEE EXTERIOR ELEVATIONS FOR FINISH.
PERFORMANCE
1. INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTION. PLACE IN CORRECT LOCATION AS SHOWN IN THE DETAILS.
LEVEL, SQUARE, AND PLUMB AT PROPER ELEVATIONS AND IN ALIGNMENT
WITH OTHER WORK. MAINTAIN SPACE IN HEAD POCKET FOR 1/4" HEAD
DEFLECTION. INSURE FRAMING PROFILES MEET INSTALLATION
REQUIREMENTS OF GLAZING UNITS TO MAINTAIN WARRANTY. SEE SECTION
8-D: GLAZING.
1. SCOPE: FURNISH AND INSTALL GLASS IN STOREFRONT AND DRIVE-THRU
SERVICE WINDOW.
2. QUALITY CONTROL: ALL GLASS BROKEN DURING INSTALLATION OR
DURING CONSTRUCTION PRIOR TO FINAL DELIVERY OF THE BUILDING TO THE
OWNER SHALL BE REPLACED AT NO ADDITIONAL EXPENSE TO THE OWNER.
GLASS SHOULD BE DELIVERED WITH LABELS PROMINENTLY DISPLAYED AND
THEY SHALL BE LEFT IN PLACE UNTIL THE OWNER'S REPRESENTATIVE
INSPECTS IT.
1. STOREFRONT GLAZING - REFER TO CONSTRUCTION DRAWINGS AND
NOTES.
1. INSTALLATION: INSTALL GLAZING WITH MANUFACTURER'S INSTRUCTIONS
TO PROVIDE COMPLIANCE WITH LOCAL CODE REQUIREMENTS INCLUDING
WIND RESISTANCE, 25 PSF MIN., SNOW LOAD, 20 PSF MIN. GLAZING PANELS
SHALL BE INSTALLED.
ULTRA VIOLET DEGRADATION LEVELS ARE TO MEET MANUFACTURER'S
REQUIREMENTS TO VALIDATE MATERIALS REPLACEMENT WARRANTY.
2. ALLOW FOR 1/4" MINIMUM HEAD DEFLECTION DUE TO LIVE LOAD.
3. GUARANTEES AND WARRANTIES: AT THE COMPLETION OF THE GLAZING,
PROVE THE INSTALLATION WATERTIGHT BY SPRAYING ALL JOINTS WITH A
GARDEN HOSE WITH NOZZLE SET FOR MAXIMUM PRESSURE. PROVIDE
ADDITIONAL CAULKING OR SEALANT, OR RESET GLASS AS NECESSARY TO
EFFECT A WATERTIGHT JOB.
EXTERIOR FINISH NOTES
E.I.F.S. WALL TEXTURE FINISH STO COLORS
Manuf. Texture NA10-0016 - DELIGHTFUL GOLDEN
STO STO ESSENCE SWIRL NA01-0061 - EXOTIC RED
DRYVIT QUARTZ PUTZ NA10-0017 - MOCHA BROWN
FINISH NOTES DRYVIT COLORS
THE FOLLOWING COMPONENTS CAN BE PURCHASED
FROM THE APPROVED SIGN VENDORS:
POPE051020 - DELIGHTFUL GOLDEN
POPE021028S - EXOTIC RED
POPE031020S - MOCHA BROWN* STANDING SEAM ROOF
* D/T WINDOW CANOPY RAILING
* CLEARANCE BAR
* MENU CANOPY
* GUARD RAIL
* AWNINGS
THE FOLOWING COMPONENTS TO BE MANUFACTURED
AND INSTALLED BY THE GENERAL CONTRACTOR
* LADDER
* DUMPSTER GATES
* SHUTTERS
GREASE & CO2
ENCLOSURE BY VENDOR
BLACK MASTIC SEALANT
CONT. TYP. AT ENTIRE
PERIMETER OF BUILDING
BASE
SCORED LINE (TYP)
6"Ø STEEL BOLLARD
TOP @ 4'-6" A.F.F.
SEE DET. A/SD3, PAINT
SAFETY YELLOW (EP-9)
ACCENT
BAND
GREASE REMOVAL PIPE
INSULATE EXPOSED PIPE
EP-2 EP-2
6'-412"
C-1
EP-3
2'-10" 6'-6" 6'-7"
SPEAKER
10'-612" 12'-1"
4'-6" 12'-1" 12'-1" 4'-6"
15'-8"
EP-5
EP-2
EP-1
ACCENT BAND
SW-1
EP-2
EP-2
EP-4 EP-4
FINISHED FLOOR
0'-0" AFF.
B.O. AWNING
9'-4" AFF
T.O. PARAPET
16'-8" AFF
T.O. PARAPET
19'-4" AFF
T.O. PARAPET
18'-0" AFF.
SW-1SW-1SW-1
EP-1
EP-1
EP-6
LADDER, PAINT MOCHA BROWN
TO MATCH STORE FRONT
C-1
BUILDING SIGN
EP-5
3'-11" 10'-8"
5'-0"
EP-1
EP-1
EP-1
EFIS
TRIM
PTD.
EP-1
12'-0"13'-0"13'-0"
5'-6"13'-0"13'-0"13'-0"11'-712"
6'-412"
C-1
EP-6
FINISHED FLOOR
0'-0" AFF.
B.O. AWNING
9'-4" AFF
T.O. PARAPET
16'-8" AFF
T.O. PARAPET
19'-4" AFF
EP-2
EP-1
ACCENT BAND
SW-1
C-1
BUILDING SIGN
IL-27
SCORED LINE (TYP)
EP-2
EP-2
EP-2
SPEAKER
SW-1SW-1
BLACK MASTIC SEALANT
CONT. TYP. AT ENTIRE
PERIMETER OF BUILDING
BASE
15'-8"
2'-10" 6'-6" 6'-7"
EP-1
EP-1
4'-9"
10'-9"3'-10"
EP-1 EP-1 EP-1
EFIS TRIM
PTD.
C-1
EP-6
3'-1012"
EP-5
INCLUDE IN METAL PACKAGE
AND INSTALLED BY G.C.NOTE:
USE QUIKSERV BP-7241E DRIVE THRU WINDOW
AT 120 M.P.H. OR HIGHER WIND ZONES. CHECK
DIMENSIONS WITH MANUFACTURER'S
DRAWINGS. COLOR TO BE DARK BRONZE -
REVISE FRAMING PLAN FOR BP-7241E WINDOW.
GUTTER & DOWNSPOUT
PAINT MOCHA BROWN
-SEE ROOF PLAN
GREASE & CO2
ENCLOSURE BY VENDOR
LADDER, PAINT
MOCHA BROWN
TO MATCH STORE FRONT
3" x 5" DOWNSPOUT
TIED INTO STORM
DRAIN, PAINT EP-3
EP-3
S-36 SEAL BUILDING
SIGN
CL
OF
SHUTTER
CL
OF
SHUTTER
CL
OF
SHUTTER
CL
OF SUPPORT
RODCL
OF SUPPORT
ROD
GUTTER & DOWNSPOUT
PAINT MOCHA BROWN
-SEE ROOF PLAN
3" x 5" DOWNSPOUT
TIED INTO STORM
DRAIN, PAINT EP-3
S-36 SEAL BUILDING
SIGN
NOTE:
CONTRACTOR TO FIELD
VERIFY DIMENSIONS.
CORE DRILLED POST
W/ SOCKETS AND
CAPS
2"x2" STEEL
TUBE POST
1/2"x1/2"
PICKETS
1"x1" STEEL
TUBE POST
1"x1" STEEL
TUBE POST
MOLDED
COVER RAIL
NOTE: SEE 6/A12 FOR
ADDITIONAL
INFORMATION
DOOR
ELEVATION
A6
1 LEFT SIDE ELEVATION
1/4"=1'-0"
A6
2 RIGHT SIDE ELEVATION
1/4"=1'-0"
A6
3 GUARD RAIL DETAIL
1/2"=1'-0"
A6
4 STOREFRONT DETAIL
1/2"=1'-0"
A6
D
Y
H
ETLING AVE. 50' R/W (S-435)
ST. JAMES AVE. 100' R/W (SC 176)
GV
GV
GM
GM
20' REAR SETBACK
20' FRONT
SETBACK
10' FRONT
SETBACK
20' FRONT
SETBACK
POPEYES
46-SEAT BLDG
2268 S.F. GROSS
~ EX ASPHALT ~
- EVANS GRACE -
TN 2430804020
DB 11135, Pg 181
PB L, Pg 270C
- CHAMPANERIA ASHESH -
TN 2430804018
DB 5895, Pg 0336
PB L, Pg 62
-SLATON DARLENE -
TN 2430804002
DB 0696, Pg 0093
PB L, Pg 57
ZONED: GC
ZONED: GC
ZONED: GC
9
7
8
10
7
0
Date:2/14/2018 Footcandles calculated at grade
1200 92nd Street - Sturtevant, WI 53177
www.cree.com - (800) 236-6800
Illumination results shown on this lighting design are based on project parameters provided to Cree, Inc. used in conjunction with luminaire
test procedures conducted under laboratory conditions. Actual project conditions differing from these design parameters may affect field results.
The customer is responsible for verifying dimensional accuracy along with compliance with any applicable electrical, lighting, or energy code.
60 120
Scale: 1"=30'
Layout by: JACOB EDLER
30
Filename: POP-180214GCSCJEE.AGI
Project Name: POPEYES - GOOSE CREEK, SC SR No. 28638
FIXTURE MOUNTING HEIGHT: 27' AFG (25' POLE + 2' BASE)
ADDITIONAL EQUIPMENT REQUIRED:
(5) CL-SSP-4011-25-OT-BZ (25' x 4" STEEL SQUARE POLE, TENON MOUNT)
(5) PB-2A4BZ TWIN TENON
(10) OSQ-AABZ ADJUSTABLE ARM MOUNT
PROPOSED POLES MEET 120MPH SUSTAINED WIND LOADS
***CUSTOMER TO VERIFY MOUNTING, VOLTAGE, AND COLOR
PRIOR TO PLACING ORDER
MH: 27
Tilt: 0
OSQ-4ME-2a
MH: 27
OSQ-4ME-2a
Tilt: 0
Tilt: 0
MH: 27
OSQ-4ME-2a
OSQ-4ME-2a
MH: 27
Tilt: 0
OSQ-4ME-2a
MH: 27
Tilt: 0
1.9 1.8 1.7
3.2 2.5 2.2 2.0 2.0 2.2 3.0 4.7 5.6 6.7 8.3 6.7 6.1 4.9
5.1 3.7 2.6 2.2 1.9 1.9 2.3 3.9 5.4 5.8 7.7 6.6 5.4 4.5
7.3 6.3 5.7 5.0 3.5 2.7 2.3 2.2 2.4 3.4 4.9 5.5 7.2 6.0 5.1 3.8 2.3 1.8
8.8 8.5 7.3 7.5 5.8 4.6 3.4 2.7 2.6 2.8 3.4 4.4 6.8 5.3 3.6 2.8 2.2 1.9 1.6
8.5 8.5 7.1 7.1 5.2 4.2 3.3 2.7 2.3 2.2 2.2 2.9 5.1 3.6 2.6 2.4 2.3 2.1 1.9 2.0 2.9
8.0 7.2 7.1 5.9 4.4 4.0 3.4 2.2 1.1 1.2 1.4 2.0 3.6 2.5 2.1 2.1 2.3 2.4 2.7 3.1 4.5
7.7 7.8 7.5 5.8 5.2 5.5 3.4 1.5 2.4 3.3 4.5 4.8 5.3
8.5 7.8 7.4 7.2 7.6 4.9 3.0 1.4 2.8 4.3 5.3 5.5 6.6
8.1 7.2 7.2 8.8 7.1 4.3 2.8 2.2 3.3 4.3 6.1 6.1 7.4 7.5
8.3 7.9 8.9 7.3 6.2 4.6 3.3 2.9 2.9 4.1 3.1 2.2 2.0 2.2 3.0 4.1 5.2 6.9 6.6 7.9 8.1
9.1 8.0 6.7 6.2 4.9 3.7 3.4 3.6 5.4 3.9 2.6 2.3 2.2 2.3 2.6 3.2 4.6 5.3 5.9 6.9
7.2 7.2 6.5 5.6 4.4 3.8 4.1 4.8 7.0 5.5 3.7 2.8 2.2 2.0 2.1 2.5 3.5 4.9 5.1 5.6
4.5 5.1 5.1 5.8 5.4 3.7 4.2 5.5 5.8 7.3 6.1 5.2 4.0 2.4 2.0 1.9 2.1 2.3 3.0 3.5 4.8
5.2 5.1 4.8 5.2 3.9 4.7 5.8 6.0 7.8 6.8 5.5 4.7 2.8 1.9 1.8 1.8 1.8
3.8 4.9 5.7 6.1 6.9 8.4 6.8 6.2 5.1 3.8 2.4 2.0 1.7 1.5
Luminaire Schedule / "Did you know that utility rebates can cover 25% or more of a products cost? Email rebates@cree.com to get help on your project!"
Symbol Qty Label Arrangement Lumens/Lamp LLF Lum. Watts Description
5 OSQ-4ME-2a 2 @ 90 DEGREES 22330 1.000 166 OSQ-A-NM-4ME-T-57K-UL-BZ
Calculation Summary; LMF = 1.00
Label Units Avg Max Min Avg/Min Max/Min
Popeyes Lot Fc 4.50 9.1 1.1 4.09 8.27
STAFF REPORT ARCHITECTURAL REVIEW BOARD
APPLICATION FOR
PROPERTY LOCATED AT 207 RED BANK ROAD
TMS # 244-13-03-008, 244-13-03-009, 244-13-03-010, 244-13-03-011
Date of Meeting: 02/19/2018
Subject: New Construction, Bldg. Elev., Site,
Landscaping, Lighting
Proposal:
The applicant Ashley Blauser- Silva, E -Z Auto Now will be
presenting an application for a new commercial building
consisting of plans for building to include elevations, colors,
materials, landscaping, site, and photometrics.
Background:The .084 acre site will be the result of combining
the four parcels currently addressed as 207, 209, 211 and 213
Red Bank Rd.
E-Z Auto
Designer
Date
2/2/2018
Scale
Not to Scale
Drawing No.
Summary
1.7
1.4
2.3
2.0
1.4
2.7
2.3
1.9
1.6
5.8
4.8
3.1
2.8
2.7
2.5
5.2
4.6
3.4
3.1
3.6
3.6
4.0
4.1
3.7
3.4
4.1
5.2
4.0
4.1
3.7
3.5
4.0
4.7
5.1
4.7
3.6
3.3
3.3
3.0
5.2
3.5
3.1
2.6
2.2
3.4
2.9
2.2
1.7
1.5
3.6
3.8
3.4
2.9
2.0
1.4
1.4
3.2
3.4
3.3
2.9
2.1
1.5
3.4
3.0
2.3
1.7
4.4
4.2
3.5
3.1
2.7
2.4
6.0
5.0
3.4
3.3
5.6
4.8
3.5
3.3
4.0
5.0
4.1
4.2
3.7
3.4
4.0
5.1
4.0
4.0
3.6
3.4
3.6
3.3
4.6
4.4
3.5
3.0
2.7
2.3
5.9
4.8
3.1
2.5
2.0
1.5
5.0
4.1
2.6
2.0
1.4
2.2
1.6
1.0 1.0
6.1
A-1
A-3A-4
A-5 A-6 A-7
Plan View
Scale - 1" = 20ft
Schedule
Symbol Label Quantity Manufactur
er
Catalog
Number Description Lamp Number
Lamps Filename Lumens Per
Lamp
Light Loss
Factor Wattage
A
6A m e r i c a n
Electric
Lighting
ATB2
40BLEDE70
XXXXX R3
4K/5K
ATB2 SERIES LED
700MA TYPE 3
4000K/5000K CCT
LED Array 1 ATB2_40BLE
DE70_XXXXX
_R3_4K_5K.i
es
11551 0.9 88
Statistics
Description Symbol Avg Max Min Max/Min Avg/Min
E-Z Auto 3.3 fc 6.1 fc 1.0 fc 6.1:1 3.3:1
RED BANK ROAD
PARISH ROAD
.#0&5%#2'2.#0 5%*'&7.'
.Ä 4'8+5+105
Ä
PERMIT
SET
REVIEW
886 Johnnie Dodds Boulevard Suite 200
Mt.Pleasant, SC 29464
Office: 843.881.0525
www.earthsourceeng.com branchgn@earthsourceeng.com
berryk@earthsourceeng.com
PLANT LEGEND
UNDERSTORY TREES
SHRUBS, GROUNDCOVERS AND GRASSES
CANOPY TREES
SOD (ZOYSIA)
Source: City of Goose Creek website. First collected Oct 24, 2026.