RecordWell Data

Planning Commission Regular Meeting — Agenda Packet

City of Beaufort · Beaufort County · General · meeting of Oct 20, 2025 · Agenda packets

Open the original document More from City of Beaufort

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

MEETING AGENDA The City of Beaufort PLANNING COMMISSION 1911 Boundary Street, Beaufort, SC 29902 Phone: 843-525-7011 ~ Fax: 843-986-5606 Monday, October 20, 2025, 5:00 P.M. City Hall, Council Cha mbers, 2nd Floor – 1911 Boundary Street, Beaufort, SC Please click the link below to join the webinar: https://us02web.zoom.us/j/85228455890?pwd=oThcl3biktSaJmbBve3EARaZ6azGo1.1 Password: 763302 Meeting ID: 852 2845 5890 Call in Phone #: 1+929 205 6099 STATEME NT OF MEDIA NOTIFICATION: "In accordance with South Carolina Code of Laws, 1976, Section 30-4-80(d), as amended, all local media were duly notified of the time, date, place and agenda of this meeting." I. Call to Order II. Pledge of Allegiance III. Review of Commission Meeting Minutes: A. September 8, 2025 Worksession Minutes B. Septe mber 15, 2025 Regular Meeting Minutes IV. Question s Relating to Military Operations V. New Business: A. Whitehall Café – 119 Whit ehall Drive. The Applicant, Court Atkins Architects are requesting to build a two-story 4,500 square foot mixed-use building in the Whitehall Development. VI Discussion of Chapter 2, 3, 4 of the Development Code. VII. Adjournment Note: If you have special needs due to a physical challenge, please call Julie Bachety at (843) 525-7011. 1 Planning Commission Work Session Minutes – September 8, 2025 CALL TO ORDER 2:20 A work session of the Planning Commission was called to order by Chairman Mike Tomy and was held in- person in the Planning Conference Room on September 8, 2025 at 1:20 PM. The meeting was recorded and streamed on Facebook in accordance with City Policy. ATTENDEES Members were in attendance: Mike Tomy, Chairman, Bill Bardenwerper, Vice-Chairman, Libby Anderson, Clinton Hallman and Benjie Morillo. Members absent: Bill Suter and Kim McFann. Staff in attendance: Curt Freese, Community Development Department Director, Christopher Klement, Planner III and Nicolas Navia, Planner I. Chairman Tomy went over a few things before the agenda items. Mr. Tomy stated that the Planning Commission Worksessions are still not being listed online. Mr. Tomy w ill call the City Manager to see what can be done. It was agreed that the Worksessions are scheduled on a regular basis for the 1 st Monday of each month. Mr. Tomy also reminded the members if there is anything other than public comments that needs to receive a response by members of city council or city governme nt from the PC, that should go through him or Mr. Bardenwerper. Mr. Tomy referred to Robert Rules of Order. DISCUSSION 6:30 A. Short-Term Rental Ordinance Changes, Section 3.6.2. Mr. Tomy asked Mr. Freese for clarification based on the letter of companies of the Short-Term Rentals (STRs). Mr. Tomy verified with Mr. Freese on Planning Commission’s (PC) role on voting on changes to City ordinances; Mr. Freese stated the PC only give s recommendations. However, since this issue is a little more complicated and since some of the changes the PC has scheduled to be discussed and decided upon at their next regular meetin g on September 15, 2025, , have repe rcussion on regulations within the Development Code, it would require PC to vote on these. Mr. Tomy stated all of it was taking out but one sentence. Mr. Freese stated it is a proposal and started at city council, similar to our code amendment process. Mr. Hallman referred to Section 3.6.2 and the listing of districts in which Short Term Rentals (STRs) are permitted. Why do these districts have STRs and what was the thinking behind the ones that don’t have STRs? Mr. Freese said if you read further it doesn’t specify a specific district, but it does refer to specific standards. Mr. Hallman referred to the T2 zoning dist rict designation. Mr. Freese stated the city does 2 not have any properties in T2. PC agreed to address this in the future when it may become more prevalent. Mr. Freese stated the PC needs to adopt the revisions within the Development Code; furthermore, if PC thinks that City Council should go further with any proposed ordinance changes, that they would first discuss and present Council with their recommendations, if they don’t think it should stay in the Development Code. Mr. Freese spoke about the differences of owner-occupied STRs vs Investor-owned Short-Term Rentals (ISTRs). Owne rs, who live on their properties, wo uld be the only ones allowed to utilize Accessory Dwelling Units (ADUs) as STRs as the Investor-owned ADUs would no longer qualify for the owner exemption.. Mr. Bardenwerper felt the ordinance was more for the investor STRs. Mr. Tomy referred to Section titled Short-Term Permits #6 where it says a designated agenda may apply for rental registration permits, that’s where its not all owner-occupied. It’s allowing multiple rentals under a single person who does not live here and, as he stated, that this does not feel right. Public Comment Lise Sundrla stated the scare, and the concern has been in the last 5 to 10 years of violence not only in the downtown area but in all of Northern Beaufort County. Vacation Rental by Owners (VRBOs) started in 2008, and the first online platforms were created in 1995. In 2017-2018, City Council pulled together and strengthened the ordinance we have now, and the city was using a company to track the STRs. People are also fearing they are losing their sense of neighborhoods. “Do we really want more owner- occupied or investors STRs?” She referred to the vacant and dilapidated buildings and said the Code encourages them to become STRs. Paul Trask stated that the person Mr. Tomy was referring to was Evey Flemming. She gave a passionate talk in front of City Council regarding the fact that she needed that income. It was very compelling and she’s probably not the only one. Public comment closed. The PC agreed to remove the IC zoning designation to the pe rmitted districts and thus to change the sentence, STRs where the owner does not live on the premises are prohibited and to remove the IC reference under numeral #2. Mr. Tomy said it is very important that the PC gets the same kind of ordinances about apartments, Bed & Breakfast, and STRs. We already have a huge problem with apartments (i.e.: Garden Oaks). PC went over the draft of the new standalone STRs ordinance. Mr. Tomy made the following comments: o Under Good Standing, item #2, it says licensed has not expired. A license shall be deemed expired ten (10) business days after the final da y of the previous business license year. Mr. Tomy feels 10 days is too short of time and maybe it should be a minimum of two weeks. o Under Investment STR Business License (ISTR), item #3, proof of inheritance shall be shown through a Deed of Distribution, court order, Will and similar documents like a Trust. Mr. Tomy feels this should be included under Good Standing for dwelling units because PC is removing “of Investment”, it should move that up. If it is owner-occupied, you want to be able to pass it along. Mr. Freese asked if PC wanted to think about the distance requirement issue. 3 Mr. Hallman referred to Section C, item #1, that there is a reference to Section 3.6.2.C.2 of the Beaufort Development Code which said “C.2” and that this should be included in the section reference. Mr. Freese will double check the section. Mr. Hallman referred to Requirements and Eligibility, item #5, the acronym of owner occupied STRs should be (all first letters) capitalized, just like ISTRs is. Mr. Tomy referred to page #2, item #8 and stated that there is one parking space provided for each bedroom being rented, should be changed to two or maybe three. Mr. Freese said we can change it here to one per unit, but the PC might have to revisit Section 5.6 of the code. Mr. Tomy referred to section D (g), which talks about no later than ten (10) days to renew an existing license and it should be a minimum of two weeks. Mr. Tomy referred to page 4, Short Term Rental Permit, item 8 (d). PC agreed to live it as it is. Mr. Tomy referred to page 6, item (p), it should be certification by the owner and a safety approval verified because a safety inspection is required. Mr . Freese said this was for the renewal to verify that a safety inspection was done. Mr. Tomy said it is required by State Law that to have an inspection of your fire extinguishers and smoke detectors every year. Mr. Tomy suggested adding verification by owner and validated annual inspection fire extinguishers, etc. Mr. Freese will look into this. Ms. Anderson referred to page 6, item (r), Wait List and wondered what happens if the 6% cap was eliminated. She also referred to F, Violations, #9, a nd said it seems a party of up to 25 people is still allowed. B. Accessory Dwelling Unit Changes, Section 3.11.2 and Section 4.5.3 Mr. Freese went over the changes that were proposed. o Section 3.11.2.F under Pool House, adding 2.A. that states, A Pool House may be utilized as an Accessory Dwelling Unit, provided the total number of Accessory Dwelling Units on a lot do not exceed 1. o 4.5.2 under Carraige House, b.2., i o The numbering is off in the document and that will be fixed. Public Comment Paul Trask said the apartments are not really affordable housing and the accessory dwelling is the best possible way to have a quality, lower cost dwelling. It also provides some extra density in the community that supports things like a neighborhood baker. Maybe under a special exception rule you can allow an investor type with certain rules. He recommend the PC promote AUDs and limit STRs. Public comment closed. Ms. Anderson suggested if two ADUs by right would be too much, maybe another option could be implemented, where either one deta ched and one attached ADU, e.g. a carriage house over a garage could still be permissible. This would reduce additional impact. The Worksession ended at 4:19 pm. 1 Planning Commission Meeting Minutes – September 15, 2025 CALL TO ORDER 3:08 A meeting of the Planning Commission was called to order by Chairman, Mike Tomy, and was held in-person on September 15, 2025, at 5:03 PM. ATTENDEES Members in attendance: Mike Tomy, Chairman, Bill Bardenwerper, Vice-Chairman, Libby Anderson, Clinton Hallman and Kim McFann. Member absent: Benjie Morillo and Bill Suter. Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community Development Planner III and Nick Navia, Community Development Planner I. MINUTES 3:51 A. August 11, 2025 Worksession Minutes Motion: Mr. Hallman made amotion to approve the August 11, 2025 Worksession Minutes. Ms. Anderson seconded the motion. The motion passed unanimously. B. August 18, 2025 Regular Meeting Minutes Mr. Bardenwerper said he was not physically present but did log in and listened to the entire meeting. Ms. Anderson abstained from voting since she was not present. Motion: Mr. Hallman made a motion to approve the August 18, 2025 regular meeting minutes. Ms. McFann seconded the motion. The motion passed unanimously. All Planning Commission meeting minutes are recorded and can be found on the City’s website at http://www.cityofbeaufort.org/AgendaCenter. QUESTIONS RELATING TO MILITARY OPERATIONS 5:45 None. 2 PUBLIC HEARING 13:06 A. Short-Term Rental Ordinance Changes, Section 3.6.2 The Planning Commission discussed draft changes to Section 3.6.2 Short Term Rentals, Accessory Uses Section 3.11.2, and Carriage Houses/Accessory Dwelling Units (ADUs) Section 4.5.3 at their September 8, 2025, work-session. The draft changes were prop osed after the August regular Planning Commission meeting, in which public discussion on Accessory Dwelling Units and Short Term Rentals was held. In addition, on August 19, 2025, The City Council held a work-session to discuss a standalone Short Term Rental (STR) ordinance to be approved as part of the Municipal Code, not the Development Code. This City Council work-session was part of a series of meetings on Short Term Rentals this year. The draft changes attached reflect the PC discussion and direction at their September 8, 2025 worksession meeting, and will be forwarded to City Council as a recommendation. Staff will coordinate the proposed changes to ADUs and STRs with the proposed standalone municipal code to regulate Short Term Rentals. Staff is recommending the attached red line changes to Section 3.6.2. This includes the recommended revisions to prohibit all non-owner Short Term Rentals. As evidenced in the redline draft, the majority of the Development Code requirements related to Short Term Rentals will be removed and such powers will be placed in the Municipal Code with expanded requirements for licensure and operation. The remaining section of the Development Code on Short Term Rentals will include permitted zoning districts, prohibited zoning districts, prohibited neighborhoods, the non-owner prohibition, and the exemption for the renovation of vacant and dilapidated homes. Mr. Freese reminded the PC that City Council is considering a separate ordinance to regulate Short Term Rentals in the Municipal Code. Should the recommended changes to Section 3.6.2 be approved by the Planning Commission, they will be forwarded with the draft Municipal Code Short Term Rental Requirements and heard together by the City Council. Mr. Freese said the PC recommendation will go to City Council. Mr. Freese said the PC will make separate motions even though he will present them together since they are somewhat combined issues that have similar connection with each other. Public Comment: Frances Ackerman, 2407 Pigeon Point Road, said Short-Term Rentals (STRs) play a valuable role in our Community. We need to make sure we foster those that follow the rules and give a good face to our community and protect the citizens that live in the neighborhoods where the STRs are. She mentioned back when she worked with Libby Anderson when we drafted those first requirements and the first once said, “there could be no transfer of a license, but there was a waiting list”. Also, what was stated in the first requirements was the police were called, it was two strikes. She referred to the STRs incident in Mossy Oaks that had 20+ serious dangerous concerns. When we had the first requirements, the license was for the particular structure, not the lot. She asked the Planning Commission to consider these three things. 3 Mr. Tomy encouraged the residents go to City Council with their comments as well. Mr. Bardenwerper asked staff if the City’s draft Ordinance was published where the community can look at it. Mr. Freese stated, “No it hasn’t yet”. The city attorney has it for review. It probably will be heard again at the next City Council worksession. Gregg Braswell, 2200 Wilson Drive is here on behalf of the Pigeon Point and Higginsville Neighborhood. What needs to be addressed is the grandfathering of the ownership transfer. He referred to clustering and Ms. Goode, who lives on Duke Street, who addressed the Planning Commission and City Council on this topic. She sits on her porch and has to look at five STRs and doesn’t recognize her neighbors anymore. Public Comment Closed. Motion: Ms. McFann made a motion to make a recommendation to City Council that the language in Section 3.6.2.A.ii to read as follows: Exceptions: Structures on the city’s list of vacant and abandoned structures, which structures are not to be demolished, are not required to be owner-occupied lots. After further discussion, Ms. McFann withdrew her motion. Motion: Ms. McFann made a motion to make a recommendation to City Council that they adopt 3.6.2 as set forth in our packet that were put together for this meeting including all of the blue line changes with the following additional changes: 1. Section 3.6.2.2.a.ii we recommended should read, Exceptions: Structures on the City’s List of Vacant and Abandoned Structures, which structures are not to be demolished but will be rehabilitated, are not required to be an owner-occupied lots. 2. Section 3.6.2.2.a in the third line down suggest the PC omit the word premises and replace it with the word “lots”. 3. Section 3.6.2.2.b we recommend it reads as follows: Short Term Rentals shall follow the specific ordinance provisions of the City of Beaufort Municipal Code pertaining to Short Term Rentals. Mr. Bardenwerper seconded the motion. The motion passed unanimously. B. Accessory Dwelling Unit Changes, Section 3.11.2 and Section 4.5.3 35:04 Staff is recommending changes to Section 3.11.2, and Section 4.5.3 (see red line changes). These changes also reflect the direction of the PC at the September 8, 2025, work session and are consistent with public discussion at the August Planning Commission meeting. The core change is to restrict ADU’s to no more than one per lot and also define pool houses and constituting an ADU. To preserve and promote affordability, while protecting the rights of the citizens nearby, the Planning Commission is recommending allowing 2 ADU’s in all zones, with a Special Exception. A Special Exception would require a public hearing before the ZOBA with the burden of proof on the Applicant, and all residents within 300’ would be notified of the meeting, with signs and legal ad posted. 4 Public Comment: Frances Ackerman, 2407 Pigeon Point Road, said the group she represents will be extremely gratified to have been heard on the one ADU per lot. It’s very important for the reasons of safety, quality of life, property values and equity and to have all the neighborhoods represented. She talked about owner- occupied for the ADUs so the investment properties cannot build three units at one time and sell them as a house and ADUs. She referred to the ADU situation on Lafayette Street. Motion: Ms. McFann made a motion to make a recommendation to City Council that they adopt changes to 3.11.2 and 4.5.3 as reflected in the blues lined with the following additional changes: 1. Section 3.11.2 we recommend that a footnote #5 be added to read as follows: a. Square footage (SF) and footprint are to be calculated as under roof. 2. Section 4.5.3 subsection B, subsection 2, add additional language after the words Special Exception to read following procedures set forth in Section 9.1.3 of this code. Mr. Hallman seconded the motion. The motion passed unanimously. Ms. Anderson asked about the calendar for 2026 next year. She said the Regular Meetings for January and February are on federal holidays. Mr. Hallman said in the past we moved the meetings that fall on holidays prior to advertisin g the schedule. Mr. Tomy asked staff to come up with the dates and we will discuss this at our next regular meeting. Mr. Tomy asked for confirmation of the future worksession dates. Mr. Freese said Monday, October 6, and November 3, which is also the first Monday. PC agreed to the two remaining dates as they are. ADJOURNMENT 1:14:29 Motion: Mr. Hallman made a motion to adjourn the meeting seconded by Ms. McFann. The motion passed unanimously. The meeting adjourned at 6:14 pm. 119 Whitehall Drive “Whitehall Cafe” Site Plan Approval STAFF REPORT: Planning Commission (PC) 119 Whitehall Drive DATE: October 20, 2025 Background: The applicant is requesting review and approval of their site plan and mixed-use project at 119 Whitehall Drive. The project name is Whitehall Café, and it is a proposed two-story, 4,500 square foot mixed-use building within Whitehall Development. The plans call for commercial space on the first floor, with a 2-unit apartment proposed for the second floor. The building is being proposed at Lot 17 of the Whitehall Development. The applicant has been to one (1) TRC Meeting on September 24th, 2024. GENERAL INFORMATION Applicant: Court Atkins Architects (Architect) Site Address / Tax PIN: 119 Whitehall Drive; R123 014 000 0168 0000 Applicant's Request: Applicant is requesting approval for the construction of Whitehall Café; a two-story, 4,500 square-foot mixed-use building in the new Whitehall Park Neighborhood. Current Zoning: T4-Neighborhood District (T4-N) Flood Zone Information: Flood Zone: SX, Elevations: 11’-12’ Lot Size: 6,620.02 square feet (0.15 acres) ZONING DISTRICT INFORMATION Lot Width at Front Setback: N/A Minimum Lot Size: N/A Max Lot Coverage: 70% of lot area (This percentage indicates maximum lot coverage by roofs; total impervious coverage may be an additional 10%. Parcels may also be subject to Section 8.3 - Stormwater) Frontage Build Out: 60% min; 85% max Front Setback: 0 ft -15 ft Side Setback: Corner/Alley: 0 ft – 10 ft; Interior: 5 ft min., 0 ft if attached Rear Setback: 10 ft min; from alley: 0 ft. Building Height: Primary Structures: 4 stories max; 3.5 stories max in & fronting Historic District & interior lots along Allison Rd Accessory Structures: 2 stories / 30 ft max SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning /Buffer required if rezoned North: T4-N 101/102 Whitehall Dr (Whitehall Development) N/A South: T4-N 122 Whitehall Dr (Whitehall Development) N/A East: T4-N 101 Whitehall Dr (Whitehall Development) N/A West: T4-N 120 Whitehall Dr (Whitehall Park) N/A 2 TRC Meeting on September 24th, 2024 – Summary of discussion points: 1. Planning and Zoning: o Must go to the Planning Commission o Can submit building plans at the same time 2. Building Codes: o Shaded X flood zone – requires minimum 13’ FFE (Finished Floor Elevation) o Windborne Debris Zone 3. Staff Architects (Meadors Architecture): o T4-N o Arcade frontage type (section 4.4.H) o Overall, staff is supportive of the proposed design o Staff recommends removing shutters from the project since they are only in select areas. If applicant wishes to keep them, they must be operable o Staff recommends enlarging the window on the second �loor behind the sinks so that they match the sill heights of the adjacent triple-ganged windows (can put paneling behind the cabinetry) 4. Stormwater: o If under 5,000 sqft disturbance, no stormwater requirements o Proper erosion control will be necessary 5. BJWSA: o Submit plans to BJWSA for review o Additional capacity fees will be required Overall Development Plan: This is lot 17 of the overall Whitehall Development Plan. All streets, parking facilities, stormwater improvements and sewer stubs have already been constructed and installed. Access: 119 Whitehall Drive utilizes the existing access built as part of the Whitehall Park development, which includes access points from Sea Island Pkwy (Hwy 21), Meridian Rd, and Harborview Drive. As the original submittal and density was part of the overall Whitehall Development submittal, a TIA is not required for this request. Compatibility with Adjacent Zoning: The site is located near the main entrance road to Whitehall Park and the new surrounding neighborhood identified in the overall Whitehall Development Plan. The entire neighborhood is zoned T4-N, with the surrounding properties within being a mix of single-family homes, townhouses, mixed-use buildings and the main public open space, Whitehall Park. The T4-N zoning district, in alignment with the conceptual Whitehall Development Plan calls for traditional neighborhood design with public open space, townhouses, and mixed-use buildings. 3 4 Compliance with City Plans – 2021 Beaufort Comprehensive Plan: The Future Land Use Map (Map 5 – Future Land Use) of the Comprehensive Plan identifies the Whitehall Development Area as “General Urban” and intends this geographic locale “as a mixed-use zone of urban residential units and commercial development”. The proposed mixed-use building, and the overall Whitehall Development, accomplishes this goal. 2014 Civic Master Plan Compliance: The Whitehall development area is mentioned extensively in the Civic Master Plan. Per Section 6.6, pg. 131 of the Civic Master Plan, “The conceptual plan for Whitehall envisions a traditional neighborhood, with the northwestern tip of the property preserved as public open space for the regional parks and greenway system. The plan illustrates one major entrance to the property, marked by a civic or religious structure, and a public green defined by townhouses and mixed-use buildings.” While the plans and specific details have ultimately changed over time from what was envisioned in 2014, mixed-use buildings were and always have been a feature envisioned for Whitehall. ZONING DISTRICT USES/DEVELOPMENT STANDARDS: Lot Configuration & Building Standards T4-Neighborhood District (T4-N) Lot Width at Front Setback N/A Lot Size N/A Max. Lot Coverage 70% of lot area (This percentage indicates maximum lot coverage by roofs; total impervious coverage may be an additional 10%.) Primary Building Height 4 stories max. Front Setback 0 ft. min.; 15 ft. max. Land Uses: The T4-Neighborhood district is a mixed-use zone of urban residential units and limited commercial development. A wide range of building types exist in the T4- Neighborhood district, including, but not limited to, apartment buildings, mixed-use buildings, rowhomes, duplexes, corner stores, and both attached and detached single-family housing. 5 DEVELOPMENT DESIGN REVIEW (MAJOR) CRITERIA Required Findings: The Planning Commission shall hold a public hearing on the proposal. At the conclusion of the public hearing, the Planning Commission may approve, deny, or approve with conditions the application for a Major Development. No Major Development shall be approved unless the following findings of fact are made. Staff analysis on the project based on these findings is accompanied below. 7.5.7.D.3 - Finding of Fact Rationale Present (yes/no) Staff Analysis of Rationale a. The plan is consistent with the City of Beaufort Comprehensive Plan and Civic Master Plan. Yes  See page 3 of the Staff Report. b. The plan complies with all applicable requirements of this Code. Yes  The proposal is consistent with the T4-N development standards as well as the Whitehall Development Plan. c. There exists adequate infrastructure (transportation and utilities) to support the plan as proposed. Yes  The proposal is part of the overall Whitehall Development Plan which ties into a multitude of automotive, pedestrian and bicycle infrastructure, connecting Whitehall to downtown Beaufort. Also, the development is located adjacent to Whitehall Park and close to Beaufort High School, Beaufort Pool, Crystal Lake as well as other commercial, educational and recreational amenities. d. The plan conforms to the character of the neighborhood, considering the location, type and height of buildings or structures and the type and extent of landscaping on the site Yes  The location of the proposal is ideal as it sits right next to the main entrance road and close to the entrance of Whitehall Park. 6 FINDINGS AND RECOMMENDATIONS Staff Recommendation: Staff recommends approval of the site plan and mixed-use building for 119 Whitehall Drive, “Whitehall Cafe”, with the following recommendations: 1. Staff recommends that applicant notes that all cementitious siding/trim/screening is to be a smooth finish. 2. Cutsheets: Applicant has only provided a lighting cutsheet at this time. Staff recommends to provide cutsheets for the rest of the materials. 3. Windows: Original recommendation was to make the small windows on the east and west elevations (above the kitchen sink) taller so that their sill heights and head heights match the adjacent windows. Applicant, upon revision, added paneling below to make up for not lowering the sill height. Staff recommends to omit the paneling and keep the windows as is. Location of subject property on City of Beaufort, SC – Zoning Map August 18, 2025 City of Beaufort Community Development Department 1911 Boundary Street Beaufort, South Carolina 29910 843-525-7011 development@cityofbeaufort.org Re: Planning Commission Submittal for Whitehall Café Community Development, We are requesting to be placed on the September 15, 2025 Planning Commission meeting agenda for Final Review for the new Whitehall Café building located at 119 Whitehall Drive. The following submittal documents are enclosed: 1. Application Form 2. Landscape Drawings 3. Architectural Drawings 4. Color Board 5. Exterior Light Fixture Cut Sheet 6. Site Survey Additionally, below are the following response to the building architecture comments during the 9/24/2024 TRC meeting: 7. The window shutters have been removed from all the exterior windows. 8. Cementitious panel was added to the bottom of the exterior window at the kitchen sink to enlarge the perceived opening and align the sill material with the adjacent windows. If you have any questions or need any additional information, please let me know. Court Atkins Architects, Inc. Jason Broene, Studio Manager CO E PLANTING PLANL500 PRELIMINARYSUBMITTAL PLAN,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2023 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB. 04, 2025XXXXX.XXEDJM REVISIONS:SITE DEVELOPMENT PLANSFORWHITEHALL CAFEBEAUFORT, SOUTH CAROLINA119 WHITEHALL DRIVE PLANT KEY LEGENDcNEW0102030405152535Scale 1 " = 10' PLANTING DETAILSDETAILDESCRIPTIONTREE PLANTING14.1CALL-OUT14.214.3PALM TREE PLANTINGSHRUB PLANTING14.4GROUND COVER PLANTING14.5ROOT BARRIER1/L5012/L5013/L5014/L5015/L501 PLANTING REFERENCE NOTES:1EXISTING TREES TO REMAIN.CONTRACTOR SHALL REPAIR OR REPLACE ANY AND ALL GRASSDAMAGED DURING CONSTRUCTION.COORDINATE SHRUB LAYOUT WITH EXISTING UTILITIES. REPORTANY CONFLICTS TO LANDSCAPE ARCHITECT.MULCH ACCESS PATH.PATIO EXTENSION. SEE ARCHITECT'S PLANS.243 6 TRAA4 PODP25 MUHC 1 SABP28 PLUA17 PODP6 TRAA8 PODP36 PLUA1 SABP16 PLUA12 PODP5 AZAG 4 PODP275 THEK PROPERTY LINEPROPERTY LINE PROPERTY LINE PROPERTY LINE SOD SOD SOD SODSODSOD BUILDING WHITEHALL DRIVE WHITEHALL DRIVE 14.2TYP. 14.3TYP. 14.4TYP. 1TYP. 2TYP. 3TYP.4 TABBY WALK TABBY WALK TABBY WALK 5 5 PLANT SCHEDULE ANDDETAILSL501 PRELIMINARYSUBMITTAL PLAN,NOT FORCONSTRUCTION DRAWING NUMBERDRAWING TITLE DESIGN CONCEPTS, DRAWING, SHEETS,LOGOS, SPECIFICATIONS, DETAILS,WRITTEN MATERIAL SHALL NOT BE USEDOR REPRODUCED IN WHOLE OR IN PARTIN ANY FORM WITHOUT PRIOR WRITTENCONSENT OF WJK LTD.© 2023 WJK LTD.THIS SHEET TO SCALE AT: 24"X36" DATE:PROJECT NO.:DRAWN BY:CHECKED BY:FEB. 04, 2025XXXXX.XXEDJM REVISIONS:SITE DEVELOPMENT PLANSFORWHITEHALL CAFEBEAUFORT, SOUTH CAROLINA119 WHITEHALL DRIVE1L501TREE PLANTINGSCALE: N.T.S.2L501PALM TREE PLANTINGSCALE: N.T.S. 3L501SHRUB PLANTINGSCALE: N.T.S.4L501GROUND COVER PLANTINGSCALE: N.T.S.5L501TREE STAKINGSCALE: N.T.S. PLANT SCHEDULE:BLACK RUBBER HOSE120°120°120°PLANDOUBLE STRAND 12 GAUGEWIREPROTECT TREE TRUNK WITH BLACK RUBBERHOSE OR APPROVED EQUALDOUBLE STRAND 12 GAUGE WIRE WITHGALVANIZED TURNBUCKLE OR APPROVEDEQUAL. MARK AS HAZARD IN LOCATIONWITH HIGH PEDESTRIAN TRAFFIC3" MINIMUM MULCH DEPTH, REFER TO PLANTSCHEDULE FOR TYPESOIL BERM TO HOLD WATERTREE 2"X4" STAKES (36" LONG) BURIED BELOWFINISH GRADE - ENSURE STAKES ARE MARKEDTO SIGNIFY HAZARD IN LOCATIONS WITHHIGH PEDESTRIAN TRAFFICFINISH GRADEB&B OR CONTAINERIZED (REFER TO PLANTSCHEDULE)SCARIFY SIDES OF HOLE TO 4" DEPTH MINIMUMAMENDED PLANTING SOIL AS NEEDED PERSOIL ANALYSISCOMPACT PLANTING SOIL BENEATHROOTBALLNOTES:1.TREE STAKING OPTIONAL, HOWEVER, LANDSCAPE CONTRACTOR RESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT (90 DEGREE/PERPENDICULAR) POSITION FOR 1 YEAR AFTER PLANTING IS COMPLETE OR UNTIL TREE ROOT SYSTEM IS FULLY ESTABLISHED AND STURDY.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER'S REPRESENTATIVE.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE 2" ABOVE FINISH GRADE. COORDINATE WITH OWNER'SREPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 12" TYP. 12"MIN. DOUBLE SIZE OFROOTBALL, TYP. CLEAR TRUNK,REFER TO PLANTSCHEDULE COMPACTED SUBGRADE AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSIS3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPEFINISH GRADESOIL BERM TO HOLD WATERMAINTAIN TREE IN A PLUMBUPRIGHT POSITION TRUNK OF PALMETTOS SHALL BENEARLY UNIFORM IN SIZE OVERENTIRE HEIGHT AND SHALL BEFREE OF OLD FROND STUBS, FIREBLACK AND OTHER DAMAGE REFOLIATED PALMETTO NOTES:1.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE,2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.SABAL PALMETTOS SHALL BE REFOLIATED, PROTECT CABBAGE HEAD FROM DAMAGE. NOTES:1.WHEN GROUNDCOVERS AND SHRUBS ARE USED IS MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL ANDPLANT MATERIAL.2.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.3.IN SEMI-IMPERVIOUS SOIL CONDITIONS, ROOTBALL ELEVATION SHALL BE ±2" ABOVE FINISH GRADE. COORDINATE WITHOWNER'S REPRESENTATIVE PRIOR TO SETTING ROOTBALL ELEVATIONS. 4" TYP.DOUBLE SIZE OFROOTBALL, TYP.AMENDED PLANTING SOIL ASNEEDED PER SOIL ANALYSISB&B OR CONTAINERIZED (SEEPLANTING SCHEDULE, THIS SHEET)FINISH GRADESOIL BERM TO HOLD WATER3" MINIMUM MULCH DEPTH,REFER TO PLANT SCHEDULE FORTYPE --- SPECIFIED O.C. SPACINGNOTE:1.EXCAVATE ENTIRE BED SPECIFIED FORGROUNDCOVER PLANTING TO A DEPTHOF 12"TYPICAL EDGE OFPLANT BED1/2 OF SPECIFIED O.C.SPACINGSPECIFIED O.C.SPACINGATYPICAL SPACING INCURVILINEAR PLANT BEDS.OUTSIDE ROW TO FOLLOWCURVE AS SHOWN ON PLAN ±5' DIA.3" MINIMUM MULCH DEPTH, REFERTO PLANT SCHEDULE FOR TYPESMOOTH CONTINUOUSLY CUT EDGETYPICAL TREETREE STAKE NOTES:1.APPLY MULCH IN A ±5' DIAMETER WHEREPROPOSED TREE PLANTINGS OCCUR IN SODOR SEEDED AREAS. GENERAL NOTES: A. NOTE TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BEEN PRODUCEDUNDER A LIMITED SERVICES AGREEMENT BETWEEN THE OWNER/OWNER'S REPRESENTATION AND COURT ATKINS ARCHI TECTS, INC. THEY ARE TO BE USEDFOR DESIGN INTENT AND IN CO ORDINATION WITH SUPPLEMENT ENGINEERING DOCUMENTS. B. THE ARCHITECT'S DRAWINGS CANNOT STAND ALONE AS C ONSTRUCTION DOCUMENTS. C. SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTU RAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE, CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION, AND TIE DOWN REQUIREMENTS. D. SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING EN GINEERING DOCUMENTS MAY BE PROVIDED, WHICH INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCULATIONS AND INSTALLATION SPECI FICATIONS BEYOND THE ARCHITECT'S BASIC LAYOUT AND SELECTIONS SUGGESTIONS. E. SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROV IDED, WHICH INDICATE ADDITIONAL SITE PLANNING, DRAINAGE, AND OT HER RELATED SITE WORK REQUIREMENTS. F. SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER / OWNER'S REPRESENTATIVES. G. BY APPLYING FOR A BUILDING PERMIT AND/OR CONSTRU CTING THE PROJECT REPRESENTED HEREIN, THE OWNER AGREES TO LIM IT THE LIABILITY OF THE ARCHITECT TO THE OWNER OF THE PROJECT FOR AL L AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER, OR CLAIMS OF EXPENSES FOR ANY SUCH ITEMS TO THE ARCHITECT'S TOTA L COMPENSATION FOR SERVICES RENDERED HEREIN. H. THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE ARCHITECT AND HAVE BEEN PREPARED SPECIFICALLY AND SOLELY FOR THE PROJECT NAMED HEREIN. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJ ECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE AR CHITECT. REPRODUCTION IS STRICTLY PROHIBITED. THE ARCHITECT SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, IN CLUDING THE COPYRIGHT. I. THE ARCHITECT HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION/ ON-SITE OBSERVATION FOR THIS PROJECT. J. FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CON TRACTOR WILL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PRO CEEDING. K. CONTRACTOR WILL VERIFY ALL EXISTING CONDITIONS I N THE FIELD-ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF T HE ARCHITECT. L. THE CONTRACTOR SHALL MAINTAIN AT THE SITE OF THE WORK, A SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL RECORD ALL CH ANGES AND DEVIATIONS FROM THE DRAWINGS ON THIS "AS-BUILT" SET, WHICH SHALL BE UPDATED AT LEAST EVERY OTHER WEEK. AT THE CLOSE OF THE JOB, THE CONTRACTOR SHALL PROVIDE ONE COMPLETE SET OF ALL AS-BUILT INFORMATION TO THE ARCHITECT IN CLEAR AND LEGIBLE F ORMAT. M. SIGNS SHALL BE LIMITED TO THE PROJECT IDENTIFICA TION SIGN. THE IDENTIFICATION SIGN SHALL IDENTIFY THE PROJECT, THE ARCHITECT AND THE CONTRACTOR. N. INFORMATION CONTAINED ON THESE DRAWINGS IS PROVI DED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK. EVERY ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDITIONS. O. WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARI FICATION FROM THE ARCHITECT BEFORE PROCEEDING. THIS WRITTEN NOTICE REQUIRED BY SOUTH CAROLINA REGU LATIONS TO THE PERMITTING AUTHORITY AND BUILDING OWNER THAT THE AR CHITECTS WILLIAM COURT AND JAMES ATKINS HAVE NOT BEEN HIRED TO PROVI DE MINIMUM CONSTRUCTION ADMINISTRATION SERVICES ON THE FOLLOWING PROJECT. OCC. TYPE (X), OCC. TYPE (X), & OCC. TYPE (X) OCCUPANCIES REGULATION 11-12.B.4 AND 5 STATE: (4) ON A PROJECT WHERE A BUILDING PERMIT HAS BEEN I SSUED AND THE SEALING ARCHITECT AND THE FIRM OF RECORD HAVE NOT BEEN ENGA GED TO PERFORM AT LEAST MINIMUM CONSTRUCTION ADMINISTRATION SERVICES, AS DE FINED IN SUBSECTION (5) BELOW, THE SEALING ARCHITECT AND FIRM MUST REPORT T O THE PERMITTING AUTHORITY AND THE BUILDING OWNER THAT HE AND THE FI RM HAVE NOT BEEN SO ENGAGED. (5) THE MINIMUM CONSTRUCTION ADMINISTRATION SERVICE S EXPECTED OF THE SEALING ARCHITECT AND FIRM DEEMED NECESSARY TO PROT ECT THE HEALTH, SAFETY, AND WELFARE OF THE PUBLIC SHALL BE PERIODIC SITE OBSERVATIONS OF THE CONSTRUCTION PROGRESS AND QUALITY, REVIEW OF CONTRACTOR SUBMITTAL DATA AND DRAWINGS, AND REPORTING TO THE B UILDING OFFICIAL AND OWNER ANY VIOLATIONS OF CODES OR SUBSTANTIAL DEVIATIONS FROM THE CONTRACT DOCUMENTS WHICH THE ARCHITECT OBSERVED. CONSTRUCTION ADMIN.: ARCHITECT COURT ATKINS ARCHITECTS, INC. 32 BRUIN ROAD P.O. BOX 3978 BLUFFTON, SC 29910 (843) 815-2557 PH (843) 815-2547 FAX GENERAL CONTRACTOR TBD ADDRESS LINE ADDRESS LINE 2 (###) ###-#### PH LANDSCAPE ARCHITECT WITMER JONES KEEPER 23 PROMENADE ST. STE. 201 BLUFFTON, SC., 29910 (843) 757-7411 PH CIVIL ENGINEER GASQUE & ASSOCIATES INC. 28 PROFFESIONAL VILLAGE CIRCLE BEAUFORT, SC., P.O. BOX 1363 (843) 522-1798 PH PROJECT TEAM: OWNER CONTACT P&M WHITEHALL 1 LLC 140 TROTTERS LOOP BEAUFORT, SC., 29907 (843) 812-6023 PH STRUCTURAL ENGINEER SHEARLOCK ENGINEERING 110 TRADERS CROSS OKATIE, SC. 29909 (843) 473-8767 PH MECHANICAL, PLUMBING & FIRE PROTECTION SUSTAINABLE DESIGN CONSULTANTS 1 DIAMOND CAUSEWAY, SUITE 7 SAVANNAH, GA., 31406 (912) 677-7716 PH ELECTRICAL ENGINEER SUSTAINABLE DESIGN CONSULTANTS 1 DIAMOND CAUSEWAY, SUITE 7 SAVANNAH, GA., 31406 (912) 677-7716 PH INTERIOR DESIGNER N/A ADDRESS LINE ADDRESS LINE 2 (###) ###-#### PH PROJECT INFORMATION: NAME OF PROJECT: 23-103 PATTERSON WHITEHALL CAFE ADDRESS: 119 WHITEHALL DRIVE BEAUFORT, SC. 29907 PROPOSED USE: MIX-USE (BUSINESS/MULITFAMILY) OWNER CONTACT: P & M WHITEHALL 1, LLC CODE ENFORCEMENT JURISDICTION: BEAUFORT COUNTY INTERNATIONAL BUILDING CODE (IBC): 2021 INTERNATIONAL MECHANICAL CODE: 2021 INTERNATIONAL PLUMBING CODE: 2021 THE NATIONAL ELECTRICAL CODE: 2020 INTERNATIONAL FUEL GAS CODE: 2021 INTERNATIONAL FIRE CODE: 2021 INTERNATIONAL ENERGY CONSERVATION CODE: 2009 ICC/ANSI A117.1: 2017 DESIGNER OF RECORD: DESIGNER NAME LICENSE NO. TELEPHONE NO. ARCHITECTURAL JAMES C. ATKINS SC #6743 (843) 815-255 7 ELECTRICAL SDC XX #XXXX (912) 677-7716 PLUMBING/FIRE PROTECTION SDC XX #XXXX (912) 677-7716 MECHANICAL SDC XX #XXXX (912) 677-7716 STRUCTURAL SHEARLOCK ENGINEERS XX #XXXX (843) 473-876 7 CIVIL GASQUE & ASS. SC #C00192 (843) 522-1798 LAND PLANNING/ W.J.K. XX #XXXX (843) 757-7411 LANDSCAPE VICINITY MAP - N.T.S. SITE POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:50 AM PLANNING COMMISSION FINAL SUBMITTAL PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 08.18.2025 23 -103 COVER A0.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 SHT. # SHEET NAME SCHEMATIC SET DESIGN DEVELOPMENT SET PRICING SET PLANNING COMMISSION FINAL SUBMITTAL A0.0 COVER X X X A0.1 GENERAL NOTES AND CODE SUMMARY X X A0.2 ABBREVIATIONS, SYMBOLS & ACCESS. DIAGS. (ANSI) X X S1.0 STRUCTURAL NOTES X S1.1 STRUCTURAL NOTES X S2.0 FOUNDATION PLAN X S2.1 FIRST LEVEL FRAMING PLAN X S2.2 SECOND LEVEL CEILING FRAMING PLAN X S2.3 ROOFING FRAMING PLAN X S2.10 FIRST FLOOR SHEARWALL PLAN X S2.11 SECOND FLOOR SHEARWAL PLAN X S3.0 FOUNDATION DETAILS X S4.0 STRUCTURAL DETAILS X S4.1 STRUCTURAL DETAILS X S4.2 STRUCTURAL DETAILS X S5.0 STRUCTURAL STEEL DETAILS X A0.3 LIFE SAFETY PLAN X X A0.4 LIFE SAFETY PLAN X X A0.5 WALL TYPES X X A1.1 ENLARGED SITE PLAN X X A1.0 ARCHITECTURAL SITE PLAN X X X A2.1 FIRST FLOOR PLAN X X X A2.2 SECOND FLOOR PLAN X X X A2.3 ROOF PLAN X X X A3.0 EXTERIOR ELEVATIONS X X X A3.1 EXTERIOR ELEVATIONS X X X A4.0 BUILDING SECTIONS X X X A4.1 BUILDING SECTIONS X X X A5.0 WALL SECTIONS X X X A5.1 WALL SECTIONS X X X A5.2 DETAILS X X A6.0 DOOR TYPES / SCHEDULE X X A6.1 WINDOW / DOOR DETAILS X X A7.0 VERTICAL CIRCULATION X X A7.2 INTERIOR ELEVATIONS X A8.0 FIRST FLOOR RCP X X A8.1 SECOND FLOOR RCP X X A9.4 PERSPECTIVES X X X P0.1 PLUMBING NOTES & SCHEDULES X P0.2 PLUMBING DETAILS X P1.1 SANITARY 1ST FLOOR PLAN X P1.2 SANITARY 2ND FLOOR PLAN X P1.3 DOMESTIC WATER 1ST FLOOR PLAN X P1.4 DOMESTIC WATER 2ND FLOOR PLAN X M0.1 MECHANICAL SCHEDULES AND NOTES X M1.1 MECHANICAL 1ST FLOOR PLAN X M1.2 MECHANICAL 2ND FLOOR PLAN X E0.1 ELECTRICAL LEGEND X E1.0 FIRST FLOOR LIGHTING PLAN X E1.1 SECOND FLOOR LIGHTING PLAN X E2.0 FIRST FLOOR POWER PLAN X E2.1 SECOND FLOOR POWER PLAN X E3.0 ELECTRICAL DETAILS X E3.41 ELECTRICAL PANEL SCHEDULES X SHEET INDEX: NO. REV. DATE DESCRIPTION R123 014 000 0002 0000 BEAUFORT COUNTY 1/2"ROD FOUND PROTECTED TREE AREA PATIO DINING CAFE 13' - 0" 12' - 11 1/2" 12' - 11 1/2" POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:51 AM 08.18.2025 23 -103 ARCHITECTURAL SITE PLAN A1.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 PLAN NORTH W S E 1" = 20'-0" A1.0 1 SITE PLAN TRUE NORTH W S E NO. REV. DATE DESCRIPTION A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE SCOPE OF WORK. B. SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCH ITECTURAL SCOPE OF SERVICES. C. SEE A0.2 FOR ANSI/ADA REQUIREMENTS. D. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AN D PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. E. ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATE S AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. F. STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHI TECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRUCTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. G. DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRA MING, U.N.O. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. H. U.N.O. WALL TYPE SHALL BE TYPE 'ZZZZZ' I. WALL TAG DESIGNATIONS ARE INTENDED FOR THE LENGT H OF THE WALL ON THE SIDE OF THE ROOM ON WHICH THE LETTER DESIGNATIO N IS LOCATED. J. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLE SS OTHERWISE DIMENSIONED. GENERAL FLOOR PLAN NOTES: FLOOR PLAN - SYMBOL KEY 6" MTL. STUD WALL WITH 5/8" GYPSUM WALLBOARD 3 5/8" MTL. STUD WALL WITH 5/8" GYPSUM WALLBOARD A WINDOW TAG 01 WALL TAG 100 DOOR TAG SOUND BATT INSULATION 1 HOUR FIRE RATED WALL A3.1 2 A3.0 2 A3.1 1 A3.0 1 1 A4.0 1 A4.1 COMMERCIAL SPACE 101 RISER 107 DELIVERY ENTRANCE 108 SERVICE YARD 110 PORCH 100 2 A4.0 4' - 1 1/2" 3' - 10" 3' - 10" 7' - 2 1/2" 7' - 2 1/2" 3' - 10" 3' - 10" 4' - 1 1/2" 2 A4.1 69' - 5" 1' - 8 1/2" 18' - 8" 28' - 8" 18' - 8" 1' - 8 1/2" 58' - 0" 10' - 0" 38' - 0" 10' - 0" EQ EQ EQ EQ EQ EQ 5' - 2" 13' - 4" 6' - 6" 6' - 6" 10' - 7" 7' - 11" 50' - 0" EQ EQ EQ 1' - 8 1/2" 1' - 8 1/2" 3' - 5 3/8" 3' - 3 1/2" 11' - 5" 13' - 8" 18' - 2 1/8" 20' - 11 1/4" 17' - 0 3/4" 14' - 3" 8' - 9" 15' - 0" E105 E106 E104 E101 E102 E103 D C C C D C AA HH A7.0 1 H A 9' - 8 1/2" 44' - 2" 5' - 10" 9' - 8 1/2" 1' - 8 5/8" 18' - 8" 28' - 8" 18' - 8" 1' - 8 3/8" 8' - 0" 2' - 0" 10' - 0" 38' - 0" 10' - 0" 9" 4" 4" 9" 4" A5.2 5 25' - 0" 25' - 0" DS DS DS DS DS DS DS DS 1' - 8 1/2" 8' - 4" 7' - 10 1/2" 16' - 11" 13' - 2 1/2" 13' - 6" 11' - 0" 13' - 6" 15' - 0" 20' - 0" 15' - 0" 25' - 0" D D COOLER ALUMN. SECURITY FENCE ADA ACCESS HARDWARE BROOM FINISH CONCRETE POLISH/SMOOTH TABBY SHELL FINISH CONCRETE POLISH/SMOOTH TABBY SHELL FINISH CONCRETE POLISH/SMOOTH TABBY SHELL FINISH CONCRETE BRICK BORDER BRICK BORDER BRICK BORDER BRICK BORDER ZZ 1 POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:51 AM 08.18.2025 23 -103 FIRST FLOOR PLAN A2.1 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A2.1 1 FIRST FLOOR PLAN PLAN NORTH W S E TRUE NORTH W S E NO. REV. DATE DESCRIPTION REF. DW REF. A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE SCOPE OF WORK. B. SEE COVER PAGE FOR NOTES AND LIMITATIONS TO ARCH ITECTURAL SCOPE OF SERVICES. C. SEE A0.2 FOR ANSI/ADA REQUIREMENTS. D. GC/OWNER TO COORDINATE ALL IN-SLAB ELECTRICAL AN D PLUMBING REQUIREMENTS WITH APPROPRIATE SUBCONTRACTOR TRADES PRIOR TO PLACING SLAB. E. ADJUST TOP OF SLAB, WALL, AND ROOF BEARING PLATE S AS REQUIRED FOR CHANGES IN STRUCTURAL MEMBER SIZES OR EXISTING SITE CONDITIONS. F. STRUCTURAL ENGINEERING DOCUMENTS SUPERSEDE ARCHI TECTURAL DOCUMENTS AND SCHEDULES WITH REGARD TO SIZE OF STRU CTURAL MEMBERS, PLACEMENT, AND CONNECTION DETAILS. G. DIMENSIONS ARE TO THE EDGE OF FOUNDATION AND FRA MING, U.N.O. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT WITH ANY DISCREPANCIES. H. U.N.O. WALL TYPE SHALL BE TYPE 'ZZZZZ' I. WALL TAG DESIGNATIONS ARE INTENDED FOR THE LENGT H OF THE WALL ON THE SIDE OF THE ROOM ON WHICH THE LETTER DESIGNATIO N IS LOCATED. J. DOOR OPENINGS SET 6" OFF INTERSECTING WALL, UNLE SS OTHERWISE DIMENSIONED. GENERAL FLOOR PLAN NOTES: FLOOR PLAN - SYMBOL KEY 6" MTL. STUD WALL WITH 5/8" GYPSUM WALLBOARD 3 5/8" MTL. STUD WALL WITH 5/8" GYPSUM WALLBOARD A WINDOW TAG 01 WALL TAG 100 DOOR TAG SOUND BATT INSULATION 1 HOUR FIRE RATED WALL A3.1 2 A3.0 2 A3.1 1 A3.0 1 KITCHEN 201 KITCHEN 301 1 A4.0 1 A4.1 10' - 0" 38' - 0" 10' - 0" 34' - 7 1/2" 34' - 7 1/2" 69' - 3" 2 A4.0 EXHAUST MAKE-UP 3'X4' SHOWER 3'X4' SHOWER 3'X5' SHOWER /TUB 3'X5' SHOWER /TUB 48" VANITY 48" VANITY 100" VANITY 100" VANITY 4'X6' ISLAND 4'X6' ISLAND 2 A4.1 A7.0 2 DINING 202 LIVING AREA 203 BEDROOM #1 207 BATH #1 208 BATH #2 205 BEDROOM #2 204 LAUNDRY 206 W.I.C. 209 DINING 302 LIVING AREA 303 BEDROOM #1 307 BATH #1 308 W.I.C. 309 LAUNDRY 306 BATH#2 305 BEDROOM #2 304 58' - 0" 10' - 0" 38' - 0" 10' - 0" 8' - 0" 11' - 0" 11' - 0" 8' - 0" 8' - 0" 11' - 0" 11' - 0" 8' - 0" 11' - 0" 16' - 10" 13' - 7" 16' - 10" 11' - 0" 17' - 3 1/2" 17' - 4" 14' - 9" 2' - 7" 17' - 3 1/2" 12' - 1 1/2" 5' - 2" 17' - 4" 17' - 4" 5' - 2" 12' - 1 1/2" 3' - 1" 2' - 1" 10' - 6" 6' - 10" 6' - 10" 10' - 6" 2' - 1" 3' - 1" 6' - 3" 3' - 6" 7' - 7" 7' - 7" 3' - 6" 6' - 3" 2' - 5 1/2" 14' - 10 1/2" 14' - 10 1/2" 2' - 5 1/2" 10' - 10" 7' - 4" 8' - 9" 4' - 7" 3' - 6" 3' - 0" 4' - 8 1/2" 4' - 5 1/2" 7' - 1" E201 E E 207 205B 208 209 205A 204A 204B E200 B F F E E 304B E300 304A 305A 309 308 307 306 305B F F E301 PORCH 210 10' - 10" 7' - 4" 8' - 9" 4' - 7" 3' - 6" 3' - 0" 7' - 2" 4' - 4 1/2" 4' - 8 1/2" PORCH 310 206 4' - 1 7/8" FRONT PORCH A B A A BA A B A B B A C A E B B B A AB B A A AB B B A 18' - 8" 18' - 8" 18' - 8" C A7.2 1 A7.2 3 A7.2 2 69' - 3" AZEK T&G DECKING AZEK T&G DECKING AZEK T&G DECKING ZZ 1 POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:52 AM 08.18.2025 23 -103 SECOND FLOOR PLAN A2.2 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A2.2 1 SECOND FLOOR PLAN PLAN NORTH W S E TRUE NORTH W S E NO. REV. DATE DESCRIPTION A3.1 2 A3.0 2 A3.1 1 A3.0 1 1 A4.0 1 A4.1 2 A4.0 10" / 12" 4" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" 10" / 12" GABLE EAVE RIDGE VALLEY EAVE VALLEY GABLE EAVE RIDGE VALLEY EAVE VALLEY GABLE EAVE RIDGE VALLEY EAVE VALLEY VALLEY GABLE EAVE RIDGE VALLEY EAVE VALLEY VALLEY EAVE ABOVE RIDGE GABLE GABLE EAVE SLOPE CHANGE 2 A4.1 8" / 12" 8" / 12" GUTTER GUTTER GUTTER GUTTER GUTTER GUTTER 1' - 4" 2' - 0" 1' - 0" 1' - 7" 1' - 0" 1' - 7" 1' - 4" 1' - 0" 1' - 7" 2' - 0" 1' - 0" 1' - 7" DS DS DS DS DS DS DS DS ZZ 1 A. AT ALL ROOF RIDGES AND HIPS USE CONTINUOUS SELF ADHERED UNDERLAYMENT CONTINUE OVER RIDGE/HIP 2" BOTH WAYS. B. AT ALL ROOF VALLEYS USE 36" SELF-ADHERED MEMBRAN E FLASHING CENTERED IN VALLEY C. VERIFY ROOF TOP EQUIPMENT CLEARANCES W/ MANUFACT URERS TO VERIFY EQUIPMENT LAYOUTS. D. COORDINATE DOWNSPOUTS TO STORMWATER GENERAL ROOF PLAN NOTES : GAF - ROYAL SOVEREIGN SHINGLES ENGLISH 12” X 36” SHINGLES - ASPHALT CONSTRUCTION - DIMENSIONS (APPROX.): 12” X 36” - EXPOSURE: 5” - BUNDLES/SQUARE:3 - PIECES/SQUARE: 79 - NAILS/SQUARE: 316 (474 WHERE 6 NAILS PER SHINGLE IS REQUIRED) - STAINGUARD®PROTECTION: YES - RIDGE CAP: ROYAL SOVEREIGN®SHINGLE - STARTER: PRO-START®; WEATHERBLOCKER™ APPLICABLE STANDARDS UL 790, CLASS A MIAMI-DADE COUNTY PRODUCT CONTROL APPROVED12-1127.03 FLORIDA BUILDING CODE APPROVEDFL10124-R12 UL 997 MODIFIED TO 110 MPH ASTM D7158, CLASS H ASTM D3161,CLASS F ASTM D3018,TYPE 1 ASTM D3462 ICC ESR-1475, ESR-3267* TEXAS DEPARTMENT OF INSURANCE ENERGYSTAR® QUALIFIED (WHITE ONLY)(U.S. ONLY)** COLORS: ASH BROWN, AUTUMN BROWN, CHARCOAL, CYPRESS TAN, GOLDEN CEDAR, NICKEL GRAY, RUSSET RED, SANDRIFT, SILVER LINING, SLATE, SUMMER SAGE, WEATHERED GRAY,AND WHITE INSTALLATION NOTE: INSTALLATION METHOD TO BE IN ACCORDANCE WITH ASTM D7158, CLASS H, 150 MPH SPECIFICATIONS DETAILED INSTALLATION INSTRUCTIONS ARE PROVIDED ON THE INSIDE OF EACH BUNDLE WRAPPER OF ROYAL SOVEREIGN®SHINGLES. RISE / RUN SLOPE DIRECTION ASPHALT SHINGLE ROOF ASPHALT SHINGLE ROOFING (COORDINATE SELECTION WITH OWNER) ROOF PLAN LEGEND 3/12 DOWNSPOUT DS POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:52 AM 08.18.2025 23 -103 ROOF PLAN A2.3 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A2.3 1 ROOF PLAN PLAN NORTH W S E TRUE NORTH W S E NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.0 13' - 0" 12' - 0" 13' - 4" 38' - 4" 10" 12" 10" 12" 2 A4.1 ARCHITECTURAL SHINGLES CEMEN. FASCIA TRIM 5/4X6 CEMEN. CORNER BOARDS 7" CEMN. HORIZONTAL LAP SIDING 1 X 10 CEMENTITIOUS WRAPPED COLUMNS ALUM. CLAD DOORS SEE SCHEDULE BOARD AND BATTEN 16" O.C. CEMEN. TRIM BOARDS WOOD RAILING 5/4 X 6 BORAL WINDOW TRIM 5/4 X 6 BORAL WINDOW HEAD TRIM ALUM. CLAD WINDOWS SEE SCHEDULE PRE-FIN. MTL GUTTER & DOWNSPOUT E E HH JJ EXTERIOR LIGHTING FIXTURES HARDI-PANEL BOARDS H WINDOW HEAD HT. 10' - 3" ABV (SLAB) WINDOW HEAD HT. 8' - 0" ASF (SECOND) E104 E201 DOOR HEAD HT. 8' - 0" ASF (SECOND) WINDOW HEAD HT. 16' - 0" ASF (SECOND) DOOR HEAD HT. 8' - 0" ABV (SLAB) E105 BOTOM OF BEAM 10' - 6" BOTTOM OF BEAM 9' - 6" ASF (SECOND) E301 3' - 6" FINISH LEVEL 13' - 1" AMSL 8" / 12" 1' - 6" DOWNSPOUTS (DS) 5/4 X 6 HARDIE PLANK SCREENING TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.1 13' - 4" 12' - 0" 13' - 0" 38' - 4" 2 A4.0 10" / 12" 10" / 12" ARCHITECTURAL SHINGLES CEMEN. FASCIA TRIM 5/4X6 CEMEN. CORNER BOARDS 7" CEMN. HORIZONTAL LAP SIDING 1 X 10 CEMENTITIOUS WRAPPED COLUMNS BOARD AND BATTEN 16" O.C. CEMEN. TRIM BOARDS WOOD RAILING 5/4 X 6 CEMEN. WINDOW HEAD TRIM ALUM. CLAD WINDOWS, SEE SCHEDULE PRE-FIN. MTL GUTTER & DOWNSPOUT G B F F 3' - 6" 3' - 6" WINDOW HEAD HT. 8' - 0" ASF (SECOND) WINDOW HEAD HT. 19' - 0" ASF (SECOND) 8" 12" A5.2 4 Sim DOWNSPOUTS (DS) 5/4 X 6 HARDIE PLANK SCREENING COORD. FIRE DEPT. ACCESS AND PRIVACY WALL A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE SCOPE OF WORK B. SEE WALL SECTIONS FOR ADDITIONAL TRIM DIMENSIONS C. WINDOW HEAD HEIGHTS AND WALL OPENING HEAD HEIGHT S ARE NOTED RELATIVE TO THE CLOSEST LEVEL BELOW. GENERAL EXTERIOR ELEVATION NOTES: POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:12:57 AM 08.18.2025 23 -103 EXTERIOR ELEVATIONS A3.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A3.0 1 NORTH ELEVATION 1/4" = 1'-0" A3.0 2 EAST ELEVATION NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.0 13' - 4" 12' - 0" 13' - 0" 38' - 4" 10" 12" 4" / 12" 2 A4.1 ARCHITECTURAL SHINGLES CEMEN. FASCIA TRIM 5/4X6 CEMEN. CORNER BOARDS 7" CEMN. HORIZONTAL LAP SIDING 1 X 10 CEMENTITIOUS WRAPPED COLUMNS ALUM. CLAD DOORS SEE SCHEDULE BOARD AND BATTEN 16" O.C. CEMEN. TRIM BOARDS WOOD RAILING ALUM. CLAD WINDOWS SEE SCHEDULE PRE-FIN. MTL GUTTER & DOWNSPOUT HARDI-PANEL BOARDS 1 X 10 CEMENTITIOUS WRAPPED COLUMNS CEMEN. TRIM BOARDS STANDING SEAM METAL ROOF E E JJ E200 E300 E103 E102 AA 16' - 0" FINISH LEVEL 13' - 1" AMSL DOWNSPOUTS (DS) 5/4 X 6 HARDIE PLANK SCREENING ALUMINUM SECURITY FENCE AND DOOR PROVIDE ADA ACCEES DOOR HARDWARE TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.1 13' - 4" 12' - 0" 13' - 0" 38' - 4" 2 A4.0 1ST T.O.P. 24' - 5 1/4" AMSL 10" / 12" 10" / 12" ARCHITECTURAL SHINGLES CEMEN. FASCIA TRIM 5/4X6 CEMEN. CORNER BOARDS 7" CEMN. HORIZONTAL LAP SIDING 1 X 10 CEMENTITIOUS WRAPPED COLUMNS ALUM. CLAD DOORS SEE SCHEDULE BOARD AND BATTEN 16" O.C. CEMEN. TRIM BOARDS WOOD RAILING ALUM. CLAD WINDOWS SEE SCHEDULE PRE-FIN. MTL GUTTER & DOWNSPOUT HARDI-PANEL BOARDS FF B G DC C E101 C D C WINDOW HEAD HT. 8' - 0" ASF (SECOND) WINDOW HEAD HT. 19' - 0" ASF (SECOND) WINDOW HEAD HT. 10' - 3" ABV (SLAB) 8" 12" A5.2 4 DOWNSPOUTS (DS) DOWNSPOUTS (DS) A. G.C. / SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE SCOPE OF WORK B. SEE WALL SECTIONS FOR ADDITIONAL TRIM DIMENSIONS C. WINDOW HEAD HEIGHTS AND WALL OPENING HEAD HEIGHT S ARE NOTED RELATIVE TO THE CLOSEST LEVEL BELOW. GENERAL EXTERIOR ELEVATION NOTES: POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:02 AM 08.18.2025 23 -103 EXTERIOR ELEVATIONS A3.1 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A3.1 1 SOUTH ELEVATION 1/4" = 1'-0" A3.1 2 WEST ELEVATION NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.1 2 A4.0 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL 1' - 10 7/8" 10' - 1 1/8" 1' - 6 3/4" 11' - 5 1/4" 38' - 4" COMMERCIAL SPACE RISER DELIVERY ENTRANCE KITCHEN 10' - 0" 10' - 0" 10' - 0" 8" 12" TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL 1 A4.0 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL 2 A4.1 A5.1 1 10" 12" 10" 12" 11' - 5 1/4" 1' - 6 3/4" 10' - 1 1/8" 1' - 10 7/8" 25' - 0" POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:03 AM 08.18.2025 23 -103 BUILDING SECTIONS A4.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A4.0 1 BUILDING SECTION 1 1/4" = 1'-0" A4.0 2 BUILDING SECTION 2 NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.1 2 A4.0 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL A5.0 1 A5.0 2 COMMERCIAL SPACE 10" / 12" 10" / 12" 1' - 10 7/8" 10' - 1 1/8" 1' - 6 3/4" 11' - 5 1/4" BEDROOM #1 BATH #1 W.I.C. BEDROOM #2 10' - 7" 9' - 10 3/4" 8" 12" 38' - 4" TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL RIDGE HT. 38' - 4" AFF 1 A4.0 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL 2 A4.1 COMMERCIAL SPACE RISER 38' - 4" 11' - 5 1/4" 1' - 6 3/4" 10' - 1 1/8" 15' - 2 7/8" C POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:03 AM 08.18.2025 23 -103 BUILDING SECTIONS A4.1 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 1/4" = 1'-0" A4.1 2 BUILDING SECTION 4 1/4" = 1'-0" A4.1 1 BUILDING SECTION 3 NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL 11' - 5 1/4" 1' - 6 3/4" 11' - 4 1/8" BEDROOM #1 COMMERCIAL SPACE R-38 OPEN CEL SPRAY FOAM INSULATION W/ IGNITION BARRIER PRE-FIN. METAL GUTTERS 5/4X6 HARDIE TRIM 2X3 KDAT. WIN. HEAD TRIM W/ PRE-FIN. MTL. FLASHING ALUM. CLAD WINDOW 2X3 CHAMFERED KDAT WD. TRIM 5/4X6 HARDIE TRIM 5/4X4 HARDIE TRIM ALUM. CLAD WINDOW 1 LAYER COMM. BLDNG. WRAP APA RATED PLYWD. SHEATHING, SEE STRUCT. R-19 CLOSED CELL SPRAY FOAM INSUL. 5/8" TYPE 'X' GYP. BD. 5/8" TYPE 'X' GYP. BD. WD. WIN. CASING (BEYOND) FOUNDATION (SEE STRUCT.) PRE-FIN. MTL. FLASHING 2X3 CHAMFERED WD. TRIM 5/4X6 HARDIE TRIM WD. STOOL & SILL, TYP. WD. WIN. CASING (BEYOND) 5/8" TYPE 'X' GYP. BD. 16" WD. FLOOR JOIST, SEE STRUCT. 5/8" TYPE 'X' GYP. BD. WD. STOOL & SILL, TYP. WD. WIN. CASING (BEYOND) 1X4 OVER 1X8 HARDIE FASCIA APA RATED PLYWD. SHEATHING, SEE STRUCT. ASPHALT SHINGLE ROOF HARDIE LAP SIDING W/ 7" EXPOSURE 2X6 PT. WD. SILL PLATE ANCHOR BOLT, SEE STRUCT. 5/8" TYPE "X" GYP. BD. 2X3 CHAMFERED WD. TRIM PRE-FIN. MTL FLASHING FOUNDATION SEE STRUCTURAL HURRICAINE CLIP, SEE STRUCT. ROOF RAFTER/TRUSS, SEE STRUCT. HARDIE SOFFIT 10' - 1 1/8" FINISH LEVEL 13' - 1" AMSL 1' - 10 7/8" 8" 12" 2' - 0" A5.2 6 STEEL BEAM SEE STRUCTURAL PLYWD. SUBFLOOR. SEE RATED ASSEMBLY DETAIL 1/A0.5 1/4" SOUND BOARD UNDERLAYMENT. SEE RATED ASSEMBLY DETAIL 1/A0.5 1" POURED UNDERLAYMENT. SEE RATED ASSEMBLY DETAIL 1 /A0.5 TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL ROOF BEARING HT. 38' - 0" AMSL 2ND TOP 36' - 1 1/8" AMSL 1ST T.O.P. 24' - 5 1/4" AMSL COMMERCIAL SPACE BEDROOM #2 1/8" PER FT SLOPE 2' - 0" 4" 12" 8" 12" WD CEILING 2X CEILING JOIST FRAMING SEE STRUCTURAL BUILT-UP BEAM SEE STRUCTURAL R-38 OPEN CEL SPRAY FOAM INSULATION W/ IGNITION BARRIER PRE-FIN. METAL GUTTERS 5/4X6 HARDIE TRIM 2X3 KDAT. WIN. HEAD TRIM W/ PRE- FIN. MTL. FLASHING ALUM. CLAD WINDOW 2X3 CHAMFERED KDAT WD. TRIM 5/4X6 HARDIE TRIM 5/4X4 HARDIE TRIM ALUM. CLAD DOOR SEE SCHEDULE 1 LAYER COMM. BLDNG. WRAP APA RATED PLYWD. SHEATHING, SEE STRUCT. R-19 CLOSED CELL SPRAY FOAM INSUL. PLYWD. SUBFLOOR. SEE RATED ASSEMBLY DETAIL 1/A0.5 5/8" TYPE 'X' GYP. BD. 5/8" TYPE 'X' GYP. BD. WD. WIN. CASING (BEYOND) FOUNDATION (SEE STRUCT.) EXPANSION JOINT 5/8" TYPE 'X' GYP. BD. 16" WD. FLOOR JOIST, SEE STRUCT. 5/8" TYPE 'X' GYP. BD. WD. STOOL & SILL, TYP. WD. WIN. CASING (BEYOND) 1X4 OVER 1X8 HARDIE FASCIA APA RATED PLYWD. SHEATHING, SEE STRUCT. ASPHALT SHINGLE ROOF HARDIE LAP SIDING W/ 7" EXPOSURE FOUNDATION SEE STRUCTURAL HURRICAINE CLIP, SEE STRUCT. ROOF RAFTER/TRUSS, SEE STRUCT. 7" CEMN. HORIZONTAL LAP SIDING 8X8 STRUCTURAL HOLLOW COLUMN WRAPPED IN CEMENTITIOUS TRIM (10X10) WOOD RAILING 7" CEMN. HORIZONTAL LAP SIDING ALIGN ALIGN ALIGN ALIGN 2X10 FLOOR JOIST SEE STRUCTURAL 5/4X6 AZEK TONGUE AND GROOVE DECKING OVER 2X10 FLOOR JOIST W/BITUMEN TAPE AT EACH JOIST TOP 1X12 HARDI BOARD 1/8" PER FT SLOPE SIGN, BY OTHERS FINISH LEVEL 13' - 1" AMSL 1' - 10 7/8" 1/4" SOUND BOARD UNDERLAYMENT. SEE RATED ASSEMBLY DETAIL 1/A0.5 1" POURED UNDERLAYMENT. SEE RATED ASSEMBLY DETAIL 1 /A0.5 1X6 HARDI BOARD BOARDS 8X8 STRUCTURAL HOLLOW COLUMN WRAPPED IN CEMENTITIOUS TRIM (10X10) A5.2 1 Sim A5.2 2 Sim 11' - 10 1/2" HARDI BOARD PANEL EXPOSED 2X FLOOR JOIST SEE STRUCTURAL BRICK BOARDER POLISHED/SMOOTH TABBY SHELL FINISH POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:04 AM 08.18.2025 23 -103 WALL SECTIONS A5.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 3/4" = 1'-0" A5.0 1 Section 4 - Callout 1 3/4" = 1'-0" A5.0 2 Section 4 - Callout 2 NO. REV. DATE DESCRIPTION TOP OF SLAB 13' - 0" AMSL SECOND FLOOR 26' - 0" AMSL A5.2 1 A5.2 2 FOUNDATION (SEE STRUCT.) ALIGN ALIGN ALIGN ALIGN 1/8" PER FT SLOPE PRE-FIN. METAL GUTTERS 1X4 OVER 1X8 HARDIE FASCIA APA RATED PLYWD. SHEATHING, SEE STRUCT. ASPHALT SHINGLE ROOF HURRICAINE CLIP, SEE STRUCT. ROOF RAFTER/TRUSS, SEE STRUCT. HARDIE SOFFIT 8X8 STRUCTURAL HOLLOW COLUMN WRAPPED IN CEMENTITIOUS TRIM (10X10) WOOD RAILING 2X10 FLOOR JOIST SEE STRUCTURAL 1X12 HARDI BOARD 1X6 HARDI BOARD BOARDS 8X8 STRUCTURAL HOLLOW COLUMN WRAPPED IN CEMENTITIOUS TRIM (10X10) HARDI BOARD PANEL 10" 12" BRICK BOARDER POLISHED/SMOOTH TABBY SHELL FINISH 5/4X6 AZEK TONGUE AND GROOVE DECKING OVER 2X10 FLOOR JOIST W/BITUMEN TAPE AT EACH JOIST TOP POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:04 AM 08.18.2025 23 -103 WALL SECTIONS A5.1 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 NO. REV. DATE DESCRIPTION 3/4" = 1'-0" A5.1 1 WALL SECTION 3 3/4" 1 1/2" 3' - 4 1/2" 3' - 6" 4" MAX. KDAT 2x4 BOTTOM RAIL (CUT TO SIZE) W/ CHAMFERED EDGE KDAT 2x4 BOTTOM RAIL (CUT TO SIZE) W/ CHAMFERED EDGE KDAT 1x2 INTERIOR NAILER KDAT 3/4" BALUSTER. 4" MAX. SPACING KDAT 1x4 ON EA. SIDE OF BALUSTER KDAT 1x2 INTERIOR NAILER KDAT 1x4 ON EA. SIDE OF BALUSTER COLUMN BEYOND 3' - 6" 1 1/2" 3' - 4 1/2" 10" 3 1/2" 7 1/4" 10" BORAL WRAPPPED COLUMNS SEE STRCUTURAL BORAL 2X8 BASE TRIM QUARTER ROUND TRIM BORAL 2X4 BASE TRIM QUARTER ROUND TRIM ALIGN ALIGN BEAM, SEE STRUCTURAL FINISH LEVEL 13' - 1" AMSL 2X10 FLOOR JOIST SEE STRUCTURAL AZEK TONGUE AND GROOVE DECKING 3/4" P.T. PLYWOOD 1X10 HARDI BOARD BOARDS 1X6 HARDI BOARD BOARDS HARDI BOARD PANEL 1" CL 10" 10" BORAL WRAPPPED COLUMNS SEE STRCUTURAL BORAL 2X8 BASE TRIM QUARTER ROUND TRIM BORAL 2X4 BASE TRIM QUARTER ROUND TRIM BEAM, SEE STRUCTURAL 1X BORAL TRIM PANEL KDAT 2X4 VERTICAL STUD AT 24" O.C. 1/2" KDAT 2X4 5/4X6 HARDIE PLANKS @ 6" O.C. KDAT 2X4 10' - 6 1/2" KDAT 2X4 VERTICAL STUD AT 24" O.C. 5/4X6 HARDIE PLANKS @ 6" O.C. ALIGN ALIGN 2' - 0" EQ EQ 1X HARDIE BOARD TIRM MATCH WINDOW CASING HARDIE BOARD PANEL SILL 1 1/2" 3 1/2" B ALUM. CLAD WINDOW, SEE DETAILS 8x8 HOLLOW CORE COLUMN SEE STRUCTURAL 10" 10" BORAL BASE TRIM 5/8" THREADED ROD SEE STRUCTURAL 1X HARDIE TRIM BOARDS SECOND FLOOR 26' - 0" AMSL 1X10 HARDI BOARD BOARDS 1X4 HARDI BOARD BOARDS 1X10 HARDI BOARD BOARDS CONT. METAL FLASHING EXTERIOR SIDING, SEE ELEVATIONS EXTERIOR SIDING, SEE ELEVATIONS MOISTURE BARRIER TABBY SHELL FINISH CONCRETE BRICK HEADER COURSE ( OR AS INDICATED ON PLAN) 45 DEGREE, TYP. FACE BRICK AS SELECTED, TYP. NOTE: SEE STRUCTURAL ENG. DOCUMENTS FOR HORIZ. TIE & JOINT REINF. DETAILS & SPACING FOR ALL BRICK WORK SOLID BRICK CORNER, FINISH & COLOR AS SELECTED NOTE: DETAILS SHOWN IN STANDARD MODULAR BRICK SOLID BRICK, FINISH & COLOR AS SELECTED POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:05 AM 08.18.2025 23 -103 DETAILS A5.2 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 NO. REV. DATE DESCRIPTION 1 1/2" = 1'-0" A5.2 1 RAILING DETAIL 1 1/2" = 1'-0" A5.2 2 COLUMN DETAIL 1 1/2" = 1'-0" A5.2 3 PRIVACY FENCE DETAIL 1 1/2" = 1'-0" A5.2 4 WINDOW PANEL DETAIL 1 1/2" = 1'-0" A5.2 5 COLUMN SECTION DETAIL 1 1/2" = 1'-0" A5.2 6 WATERTABLE DETAIL 1 1/2" = 1'-0" A5.2 7 BRICK CORNER DETAIL A. EGRESS DOORS AND HARDWARE SHALL COMPLY WITH 2021 IBC, SECTION 1010.1.9 WHEN BUILDING IS OCCUPIED. B. DOOR HARDWARE TO BE ADA COMPLIANT PER 2021 IBC & ANSI 117.1 2017. C. DOOR BOTTOM RAILS SHALL COMPLY WITH ANSI 117.1 2 017 SECTION 404.2.9 (10" MIN. SMOOTH BOTTOM RAIL) D. DOOR SWING PER FLOOR PLANS E. PROVIDE IMPACT RESISTANT GLAZING FOR OPENING PRO TECTION AT ALL WINDOWS AND DOORS IN ACCORDANCE WITH 2021 IBC, SECTION 1609.2. F. G.C. TO SUBMIT SHOP DRAWINGS FOR REVIEW. G. DESIGN PRESSURE RATING (DP) SHALL MEET THE REQUI REMENTS AS NOTED ON THE STRUCTURAL DRAWINGS AND MEE T ALL APPLICABLE BUILDING CODE REQUIREMENTS. H. G.C. TO COORDINATE ROUGH OPENINGS PER MANUFACTUR ERS SPECIFICATIONS. I. G.C. TO PREPARE EXTERIOR OPENINGS PER ASTM E2112 -23. J. GLAZING TYPES: 1. IG - IMPACT GLAZING 2. S - SAFETY GLAZING PER IBC 2406.4.1 THROUGH 2406.4.3 & TABLE 2406.2 (1) OR TABLE 2406.2 (2) K. GLAZING TO MEET THE FOLLOWING CRITERIA: 1. SHGC - 0.29 2. U-FACTOR - 0.55 GENERAL DOOR / DOOR SCHEDULE, STOREFRONT & WINDOW N OTES: CLAD DIRECT SET UNITS W/ MATCHING 2'-0" TRANSOM 3'-0" x 6'-0" (R.O. ± 3'-0" x 8'-3") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT A 10' - 3" 2' - 0" 3" 6' - 0" 3' - 0" 8' - 3" CLAD DUBLE HUNG UNITS 3'-0" x 4'-0" (R.O. ± 3'-0" x 4'-3") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT B 8' - 0" 4' - 0" 3' - 0" CLAD DIRECT SET UNITS W/ MATCHING 2'-0" TRANSOM 1'-10" x 6'-0" (R.O. ± 1'-10" x 8'-3") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT C 10' - 3" 2' - 0" 3" 6' - 0" 1' - 10" 8' - 3" CLAD DIRECT SET UNITS W/ MATCHING 2'-0" TRANSOM 5'-4" x 6'-0" (R.O. ± 5'-4" x 8'-3") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT D 10' - 3" 2' - 0" 3" 6' - 0" 5' - 4" 8' - 3" CLAD DUBLE HUNG UNITS (2)3'-0" x 6'-0" (R.O. ± 6'-0" x 6'-0") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT E 8' - 0" 6' - 0" 6' - 0" 3' - 0" 0" 3' - 0" CLAD DUBLE HUNG UNITS (3)3'-0" x 6'-0" (R.O. ± 9'-0" x 6'-0") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT F 8' - 0" 6' - 0" 9' - 0" 3' - 0" 3' - 0" 3' - 0" CLAD DIRECT SET UNITS 3'-0" x 4'-0" (R.O. ± 3'-0" x 4'-0") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT G 8' - 0" 4' - 0" 3' - 0" CLAD DIRECT SET UNITS W/ MATCHING 2'-0" TRANSOM 3'-0" x 6'-0" (R.O. ± 3'-0" x 8'-3") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT H 2' - 0" 3" 6' - 0" 8' - 3" 6' - 0" 3' - 0" 3' - 0" 10' - 3" CLAD DIRECT SET UNITS 3'-0" x 4'-0" (R.O. ± 3'-0" x 4'-0") SDL MUNTINS W/ SPACER BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT J SEE ELEVATIONS 2' - 8" 2' - 0" EXTERIOR DOOR SYSTEM (MATERIAL T.B.D.) W/MATCHING 2'-0" TRANSOM OUTSWING DOOR (3)3'-0" x 8'-0" (R.O. ±9'-6" x 10'-3") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E101 EXTERIOR DOOR SYSTEM (MATERIAL T.B.D.) W/ MATCHING 2'-0" SIDELITES OUTSWING DOOR 3'-0" x 8'-0" (R.O. ±7'-6" x 8'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E102 E103 EXTERIOR DOOR SYSTEM (MATERIAL T.B.D.) OUTSWING DOOR 3'-0" x 8'-0" (R.O. ±3'-0" x 10'-3") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E104 EXTERIOR HM DOOR SYSTEM (MATERIAL T.B.D.) OUTSWING DOOR 3'-0" x 8'-0" (R.O. ±3'-0" x 8'-0") MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E105 E106 EXTERIOR DOOR SYSTEM (MATERIAL T.B.D.) OUTSWING DOOR 3'-0" x 8'-0" (R.O. ±3'-0" x 8'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT PRIVACY GLASS AND "SMART LOCK" HARDWARE ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E200 EXTERIOR SLIDER DOOR SYSTEM (MATERIAL T.B.D.) OUTSWING DOOR (4)3'-0" x 8'-0" (R.O. ±12'-0" x 8'-0") SDL MUNTINS W/ SPACE BAR (PATTERN AS SHOWN) MANUFACTURER T.B.D. BY G.C. / OWNER DP RATING 50 OR APPROVED EQUIVALENT ADJUST DOOR HEIGHT TO ENSURE TRUE 8' -0" & 10' -3" ROUGH OPENINGS - TOP OF DOOR & TRANSOMS TO ALIGN W/ TOP OF ADJACENT WINDOWS E201 E301 E300 10' - 3" 8' - 0" 3" 2' - 0" 9' - 6" 3' - 0" 3' - 0" 3' - 0" 8' - 0" 7' - 6" 2' - 0" 3' - 0" 2' - 0" 10' - 3" 2' - 0" 3" 8' - 0" 6' - 0" 3' - 0" 3' - 0" 8' - 0" 3' - 0" 8' - 0" 3' - 0" 8' - 0" 12' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:05 AM 08.18.2025 23 -103 DOOR TYPES / SCHEDULE A6.0 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 WINDOW SCHEDULE TYPE MARK WINDOW TYPE DESCRIPTION R.O. HEAD HEIGHT DESIGN PRESSURE COMMENTS WIDTH HEIGHT A CLAD DIRECT SET UNIT W/ 2'-0" TRANSOM 3'0" x 6'-0" 3 ' - 0" 8' - 3" 10' - 3" B CLAD DOUBLE HUNG UNIT 3'-0" x 4'-0" 3' - 0" 4' - 0" 8' - 0" C CLAD DIRECT SET UNIT W/ 2'-0" TRANSOM 1'10" x 6'-0" 1' - 10" 8' - 3" 10' - 3" D CLAD DIRECT SET UNIT W/ 2'-0" TRANSOM 5'-4" x 6'-0" 5' - 4" 8' - 3" 10' - 3" E CLAD DOUBLE HUNG UNITS (2) 3'-0" x 6'-0" 3' - 0" 6' - 0" 8' - 0" F CLAD DOUBLE HUNG UNITS (3) 3'-0" x 6'-0" 3' - 0" 6' - 0" 8' - 0" G CLAD DIRECT SET UNIT 3'-0" 4'-0" 3' - 0" 4' - 0" 19' - 0" H CLAD DOUBLE HUNG UNITS W/ TRANSOM (2)3'-0" x 6'-0" 3 ' - 0" 8' - 3" 10' - 3" J CLAD DIRECT SET UNIT 2'x3' 2' - 0" 2' - 8" 16' - 0" DOOR SCHEDULE DOOR NO. ROOM SIZE DOOR FRAME DETAILS RATING HARDWARE REMARKS W H T PANEL MATERIAL ELEV. FRAME WIDTH MATERIAL JAMB HEAD SILL /THRESH. TYPE CLO. STOP PANIC 204A BEDROOM #2 3' - 0" 8' - 0" 1 1/2" X 204B BEDROOM #2 4' - 0" 8' - 0" 1 3/4" X 205A BATH #2 2' - 10" 8' - 0" 1 1/2" 205B BATH #2 2' - 10" 8' - 0" 1 1/2" 206 LAUNDRY 6' - 0" 8' - 0" 1 1/2" X 207 BEDROOM #1 3' - 0" 8' - 0" 1 1/2" X 208 BATH #1 2' - 8" 8' - 0" 1 1/2" X 209 W.I.C. 2' - 4" 8' - 0" 1 1/2" 304A BEDROOM #2 3' - 0" 8' - 0" 1 1/2" X 304B BEDROOM #2 4' - 0" 8' - 0" 1 3/4" X 305A BATH#2 2' - 10" 8' - 0" 1 1/2" 305B BATH#2 2' - 10" 8' - 0" 1 1/2" 306 LAUNDRY 6' - 0" 8' - 0" 1 1/2" X 307 BEDROOM #1 3' - 0" 8' - 0" 1 1/2" X 308 BATH #1 2' - 8" 8' - 0" 1 1/2" X 309 W.I.C. 2' - 4" 8' - 0" 1 1/2" E101 COMMERCIAL SPACE 3' - 0" 10' - 3" E102 COMMERCIAL SPACE 3' - 0" 8' - 0" E103 COMMERCIAL SPACE 3' - 0" 8' - 0" E104 COMMERCIAL SPACE 6' - 0" 10' - 3" E105 COMMERCIAL SPACE 3' - 0" 8' - 0" 1 1/2" X E106 RISER 3' - 0" 8' - 0" 1 1/2" X E200 FRONT PORCH 3' - 0" 8' - 0" E201 LIVING AREA 6' - 0" 8' - 0" E300 FRONT PORCH 3' - 0" 8' - 0" E301 LIVING AREA 6' - 0" 8' - 0" E305 COMMERCIAL SPACE 3' - 6" 7' - 0" 1" F NO. REV. DATE DESCRIPTION NOTE: CAP, HEAD, & JAMB TRIM TO BE SHIMMED TO ENSURE THEY LAY FLAT & JOIN TIGHTLY ALUM. CLAD WOOD WINDOW AS SCHEDULED - INSTALL, FLASH, AND CAULK ALL WINDOWS AND DOORS PER ASTM E 2112-01 CONT. MANUF. DRIP FLASHING BACKER ROD & SEALANT AT PERIMETER PER MANUF. INSTRUCTIONS TYPICAL EXTERIOR WALL PER WALL SECTIONS HEADER AS SCHEDULED, REFER TO STRUCT. DWGS FOR HEADER ASSEMBLY DETAILS CONT. PRE-FINISHED METAL DRIP CAP FLASHING W/ HEMMED EDGE - SEAL TOP VERTICAL LEG OF FLASHING W/ S.A.F. 2x6 BORAL HEAD TRIM 2X BORAL DRIP CAP (CUT CHAMFER TO DRAIN AND DRIP CHANNEL INTERIOR WALL FINISH & HEAD AND CASINGS AS SELECTED BY OWNER BACKER ROD & SEALANT APPLIED FROM INSIDE LAP WEATHER RESISTANT BARRIER OVER NAILING FLANGE AND CONT. MANUF. DRIP FLASHING, TYP. CONT. FLEXIBLE, SELF-ADHERING FLASHING (S.A.F.) OVER TOP OF DRIP CAP FLASHING AND EXTEND VERTICAL, UP FACE OF W.R.B., TYP. SHIM, PER MANUF. REQS. CONT. FLEXIBLE, SELF-ADHERING FLASHING (S.A.F.) OVER WINDOW NAILING FLANGE AND VERTICAL, UP FACE OF SHEATHING, TYP., SEE TYPICAL WINDOW FLASHING DETAIL 1/A5.3 CONT. BEAD OF SEALANT AT HEAD AND E.A. JAMB (BEHIND NAILING FLANGE), TYP. JAMB EXTENSION OVER BLOCKING AS NEEDED 4" MIN. WEATHER RESISTANT BARRIER/ DRAINAGE PLANE OVER EXT. PLY-WD SHEATHING (SEE STRUCT. DWGS) SIDING, PER EXTERIOR ELEVATIONS 1" ALUM. CLAD WOOD WINDOW AS SCHEDULED - INSTALL, FLASH, AND CAULK ALL WINDOWS AND DOORS PER ASTM E 2112-01 INTERIOR WALL FINISH & CASINGS AS SELECTED BY OWNER TYPICAL EXTERIOR WALL PER WALL SECTIONS BACKER ROD & SEALANT AT PERIMETER PER MANUF. INSTRUCTIONS 2x4 BORAL JAMB SILL BEYOND - SEE DETAIL NOTE: CAP, HEAD, & JAMB TRIM TO BE SHIMMED TO ENSURE THEY LAY FLAT & JOIN TIGHTLY TYP. 1" CHAMFERED SILL TO EXTEND 1" AT EA. SIDE (OVERLAP) AT JAMB AND SLOPE TO DRAIN AND DRIP CHANNEL) BACKER ROD & SEALANT APPLIED FROM INSIDE SHIM, PER MANUF. REQS. SELF ADHESIVE FLASHING (SAF) AT WINDOW JAMB AND OVER WINDOW FLANGE AND W.R.B., TYP. WEATHER RESISTANT BARRIER (W.R.B.), TYP., SEE TYPICAL WINDOW FLASHING DETAIL 1/A5.3, EXTEND W.R.B THROUGH OPENING FRAMING BEYOND, TYP. CONT. BEAD OF SEALANT AT HEAD AND E.A. JAMB (BEHIND NAILING FLANGE), TYP. JAMB EXTENSION OVER BLOCKING AS NEEDED 4" MIN. WEATHER RESISTANT BARRIER/ DRAINAGE PLANE OVER EXT. PLY-WD SHEATHING (SEE STRUCT. DWGS) SIDING, PER EXT. ELEVATIONS BORAL 2" CHAMFERED SILL W/ 1" OVERLAP OF JAMBS (SILL SLOPED TO DRAIN AND DRIP CHANNEL) CONT. SILL 'PAN' FLASHING PER ASTM E2112-07 - CONT. ACROSS SILL TIGHT AGAINST JAMBS W/ END DAMS SET IN BED OF SEALANT, TYP., AND BOTTOM "LIP" OF SILL FLASHING FOLDED DOWN BACKER ROD & SEALANT AT PERIMETER, PER MANUF. INSTRUCTIONS NOTE: CAP, HEAD, & JAMB TRIM TO BE SHIMMED TO ENSURE THEY LAY FLAT & JOIN TIGHTLY TYPICAL EXTERIOR WALL PER WALL SECTIONS INTERIOR WALL FINISH & WINDOW STOOL / APRON TRIM AS SELECTED BY OWNER ALUM. CLAD WOOD WINDOW AS SCHEDULED - INSTALL, FLASH, AND CAULK ALL WINDOWS AND DOORS PER ASTM E 2112-01 AT OPENING FRAMING BEYOND, EXTEND S.A.F. UP 6" AT JAMBS , TYP., SEE TYPICAL WINDOW FLASHING DETAIL 1/A5.3 CONT. PRE-FINISHED METAL DRIP FLASHING W/ HEMMED EDGE, TUCKED UNDER CONT. "LIP" OF SILL PAN FLASHING, TYP. SAF AT WINDOW SILL & OVER W.R.B. TYP. 1" 4" MIN. 6" MIN. WEATHER RESISTANT BARRIER (W.R.B.), TYP., SEE TYPIC AL WINDOW FLASHING DETAIL 1/A5.3, EXTEND W.R.B THROUGH OPENING FRAMING BEYOND, TYP. 1/2" BEYOND - 5/4x4 BORAL JAMB TRIM 2" WEATHER RESISTANT BARRIER/ DRAINAGE PLANE OVER EXT. PLY- WD SHEATHING (SEE STRUCT. DWGS) PRE-SLOPED SILL IN ROUGH FRAMING, FOLD IN W.R.B. AT SILL SIDING, PER EXTERIOR ELEVATIONS APPROVED WEATHER RESISTANT BARRIER (W.R.B. - HYDROGAP) ON EXTERIOR SHEATHING OVER 2X6 EXT. WALL FRAMING CUT WEATHER RESISTANT BARRIER (W.R.B.) LINE OF DOOR ROUGH OPENING STEP 1 FOLD WEATHER BARRIER IN AND AROUND ROUGH OPENING, TIGHTLY AND SECURE TO BACK OF ROUGH OPENING (HEAD AND JAMBS) STEP 2 INSTALL DOOR PLUMB, LEVEL AND SQUARE PER MANUFACTURER'S INSTRUCTIONS SET THRESHOLD IN BED OF SEALANT - APPLY SEALANT AT CORNERS AND FRONT EDGE OF THRESHOLD STEP 3 6" 6" 6" INSTALL SELF-ADHERING FLASHING (6" W) AT EACH JAMB - OVERLAP DOOR FRAME 1/4" STEP 4 6" 1" 1" INSTALL SELF ADHERING FLASHING (6"W) AT HEAD - OVERLAP DOOR FRAME 1/4" - EXTEND 1" BEYOND MEMBRANE AT EACH JAMB STEP 5 DOOR FLASHING NOTES: • IF DOOR IS UNPROTECTED, ROUGH JAMBS TO BE PRESSURE TREATED OR COMPOSITE. • SEE DOOR/ WINDOW DETAILS FOR FLASHING AT TRIM. • SEE LARGE SCALE SECTION FOR THRESHOLD SET IN SILL PAN FLASHING. CUT W.R.B. AT 45 DEGREE ANGLE MODIFIED "T" CUT IN W.R.B. LINE OF WINDOW ROUGH OPENING STEP 1 APPROVED WEATHER RESISTANT BARRIER (W.R.B. - HYDROGAP) ON EXTERIOR SHEATHING ON WOOD STUD WALL 7" 135° STEP 2 FOLD AND SECURE W.R.B. "FLAP" AT HEAD EXPOSED SHEATHING STEP 3 6" 10" NO FASTENERS THRU FLASHING AT SILL ONE PIECE OR MULTIPLE PIECE FORMABLE SELF-ADHERING FLASHING - LAPPED WATER TIGHT STEP 4 6" 10" APPLY CONTINUOUS BEAD OF SEALANT AT HEAD AND JAMBS STEP 5 STEP 6 STEP 8 INSTALL WINDOW WITH NAILING FLANGE - PLUMB, LEVEL AND SQUARE PER MANUFACTURER'S INSTRUCTIONS 1" CONT. SILL 'PAN' FLASHING PER ASTM E2112-07 - CONT. ACROSS SILL TIGHT AGAINST JAMBS W/ END DAMS SET IN BED OF SEALANT, TYP., AND BOTTOM "LIP" OF SILL FLASHING FOLDED DOWN SELF-ADHERING FLASHING (6"W) AT JAMBS OVER NAILING FLANGES - 6" ABOVE HEAD AND 1" BEYOND SILL FLASHING PRE-SLOPED SILL IN ROUGH FRAMING, FOLD IN W.R.B. AT JAMBS AND SILL, SECURE FOLD DOWN W.R.B. - TAPE CORNER CUTS AND SEAL ACROSS HEAD 6" STEP 7 6" SELF-ADHERING FLASHING (6"W) AT HEAD OVER NAILING FLANGE AND 1" BEYOND JAMB FLASHING STEP 9 6" 6" 1" 1" CAULK AND SEAL WINDOW JAMB TO ROUGH JAMB, CREATING A COMPLETE AIR SEAL ON SIDES, TOP AND BOTTOM INSTALL CAULK BACKER ROD AT INSIDE EDGE OF WINDOW JAMB (ALLOWING FOR A DRAINAGE PLANE BETWEEN NAILING FLANGE AND BACKER ROD) NOTE: BOTTOM DOES NOT GET TAPED TO ALLOW FOR ANY MOISTURE TO DRAIN OUT ONTO W.R.B. POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:06 AM 08.18.2025 23 -103 WINDOW / DOOR DETAILS A6.1 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 NO. REV. DATE DESCRIPTION 3" = 1'-0" A6.1 1 WINDOW HEAD DETAIL (SIDING) 3" = 1'-0" A6.1 2 WINDOW JAMB DETAIL (SIDING) 3" = 1'-0" A6.1 3 WINDOW SILL DETAIL (SIDING) 1/4" = 1'-0" A6.1 4 TYP. EXT. DOOR FLASHING DETAIL 1/4" = 1'-0" A6.1 5 TYP. WINDOW FLASHING DETAIL POST OFFICE BOX 3978 BLUFFTON, SC 29910 PH: 843.815.2557 FX: 843.815.2547 WWW.COURTATKINS.COM ISSUE PROJECT INFO SHEET TITLE Date Project No. COPYRIGHT 2023 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF THESE DOCUMENTS WILL RESULT IN LEGAL ACTION. NOT FOR C ONSTRU CTION NOT FOR C ONSTRU CTION © 8/18/2025 8:13:14 AM 08.18.2025 23 -103 PERSPECTIVES A9.4 PATTERSON WHITEHALL CAFE 119 WHITEHALL DRIVE BEAUFORT, SC., 29907 A9.4 1 MAIN ENTRY (NORTHWEST) VIEW A9.4 2 SOUTHEAST CORNER VIEW A9.4 3 SUNROOM (NORTH) VIEW NO. REV. DATE DESCRIPTION ARCHITECTURAL SHINGLES GAF TIMBERLINE UHDZ - WEATHERED WOOD 7" SIDING & BOARD & BATTEN SHERWIN WILLIAMS - AGREEABLE GRAY SW7029 PLANK SCREENING RAILING & STAIRS COURT ATKINS GROUP 32 BRUIN ROAD, BLUFFTON, SC 29910 +1 843 815 2557 RESIDENTIAL | COMMERCIAL | INTERIORS © COPYRIGHT 2024 COURT ATKINS GROUP - THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND IS NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. ANY UNAUTHORIZED REPRODUCTION OR REUSE OF TH ESE DOCUMENTS WILL RESULT IN LEGAL ACTION. PATTERSON WHITEHALL CAFE 08.18.2025 TRIM & COLUMNS SHERWIN WILLIAMS - PURE WHITE SW7005 WINDOWS & DOORS BRONZE SHERWIN WILLIAMS - URBANE BRONZE SW7048 SHERWIN WILLIAMS - URBANE BRONZE SW7048 Discussion of Chapter 2, 3, 4 of the Development Code SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director Date: October 1, 2025 From: Curt Freese, Community Development Director To: PC ISSUE: Chapter 2 (Lot Standards) Summary of Revisions Chapter 2 Standards 2.4.1 Transect-Based District Standards • Maximum Lot Coverage: In T3-S, the maximum lot coverage by roofs is revised to 45% of the lot area (previously 30%). In T5-UC, it is revised to 90% (previously 100%). • Frontage Build-Out: In T4-N, the minimum frontage build-out is revised to 60% (previously not specified). In T5-UC, it is revised to 60% minimum (previously 75% minimum). Accessory Building Placement (2.4.1.C): • Detached Garage Door/Carport Setback: In T3-N, T4-HN, and T4-N, the setback for detached garage doors/carports from the front facade is revised to 5 ft minimum (previously 20 ft minimum). In T5-DC and T5-UC, detached garages must be located behind the primary building and accessed via an alley or side street. Encroachments 2.5.6: • Add encroachment for HVAC units up to 3’. remove fencing standards as new Standards were adopted, and current encroachments are not clear. Lot Diversity: 2.5.9 (New) • Housing Diversity Types: Revised to include specific housing types to satisfy lot diversity. These rules, apply to development plans and reflect a planning strategy to enhance community diversity, improve aesthetics, and support sustainable urban growth. Below is a detailed explanation of the rules and their impacts: • Objective: Requires a mix of permitted housing types in residential development plans, tailored to the parcel size, to the extent reasonably feasible. SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director • Minimum Standards: • 5 acres or more: At least two housing diversity types. • More than 10 acres: At least three housing diversity types. • More than 20 acres: At least four housing diversity types. • Phased Developments: These standards apply to plans that are part of a phased overall development, ensuring diversity is maintained across stages. • Rationale: This tiered approach encourages variety based on scale, preventing uniform housing patterns and supporting diverse community needs. b. Variation and Distribution • Objective: Mandates significant and substantial variation in housing types, block dimensions, garage placement, lot sizes, and lot dimensions to avoid repetitive rows and monotonous streetscapes. • Examples: • Distinct single-family or two-family dwellings on larger or corner lots. • Small lot single-family dwellings on smaller lots abutting common open spaces. • Distribution Requirement: • Diversity and density must be spread harmoniously throughout the development, not concentrated in one area. • Disconnected areas of density or different lot uses are prohibited, ensuring a cohesive layout. • Rationale: This promotes visual interest, functional diversity, and equitable access to amenities, aligning with Beaufort’s Transect-based planning goals for walkable, mixed-use environments. • Enhanced Variety: Residents benefit from diverse housing options, catering to different demographics (e.g., young families, seniors, renters), and reducing the monotony of uniform subdivisions. • Improved Streetscapes: Varied block dimensions and lot sizes create more interesting, pedestrian-friendly environments, supporting the Transect approach’s emphasis on walkability. • Equitable Development: Spreading density harmoniously prevents isolated high-density pockets, promoting balanced growth and access to amenities. SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director 2.6.2 Building Height Above Grade: • General to All Zones: The freeboard requirement in flood-hazard zones is revised to mandate that new construction, substantial improvement, or additions (where the footprint exceeds 33% of the existing structure) have the lowest floor elevated to the most restrictive of 13 ft or the base flood elevation plus 1 ft of freeboard (previously 1 ft above base flood elevation). No basements are permitted, and solid foundation perimeter walls must include openings for floodwater movement per National Flood Insurance Program standards. 2.6.6 Height Transition: • The Revised Ordinance applies to buildings in the T-4 (Historic Neighborhood and Neighborhood), T-4N (Neighborhood Artisan), T5-UC (Urban Corridor), and RMX (Regional Mixed-Use) districts. These are mixed-use or higher-density transect-based and conventional districts, indicating a focus on urban or transitional areas where height variations are common. Height Limitation: • The maximum height of any building portion within these districts, within a 75-foot distance from the boundary line of an adjacent zoning district, must not exceed the maximum height permitted in that adjacent district. This creates a buffer zone to ensure a gradual transition in building heights, preventing abrupt changes that could disrupt the visual or functional character of neighboring areas. Measurement Starting Point: • The 75-foot distance is measured beginning at the zone district boundary line where districts share a direct border. • If a street separates the zoning districts, the measurement starts from the street right- of-way line opposite the T-4, T-4N, T5-UC, or RMX District. This adjustment accounts for SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director the street as a physical divider, ensuring the height restriction applies consistently across different site configurations. Rationale and Impact • The revision aims to promote compatibility between zoning districts with differing height allowances, particularly in mixed-use or urbanizing areas. For example, a T5-UC district (with a 5-story maximum) adjacent to a T3-N district (2.5-story maximum) would need to limit heights near the boundary to 2.5 stories within 75 feet. This prevents overshadowing, preserves neighborhood character (e.g., historic areas in T-4), and reduces potential conflicts like privacy or traffic impacts. • The street adjustment reflects practical site planning, recognizing that streets often serve as natural transitions and may require a different measurement baseline to maintain proportionality. • Development Constraints: Developers in T-4, T-4N, T5-UC, or RMX districts must design buildings to taper heights near boundaries, potentially increasing costs for stepped or varied designs. For instance, a 4-story building in T4-N might need to step down to 2.5 stories near a T3-N boundary. • Visual Harmony: This fosters a more cohesive urban fabric, especially in Beaufort’s historic or pedestrian-oriented zones, aligning with the Transect approach’s emphasis on scale and intensity. Sections 2.7-2.8 Overlay Standards (remove and replace in Chapter 3). • Remove Overlay Standards and Place in the More appropriate Zoning Chapter 3. Beaufort, South Carolina, The Beaufort Development Code 2: MAP AND DISTRICTS Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 1 of 73 2: MAP AND DISTRICTS 2.1: PURPOSE AND INTENT For the purposes of this Code, the various districts have been categorized as Transect -based districts (as explained in Section 2.3.1) and conventional districts. In general, standards and provisions for Transect -based districts are designed to create walkable, mixed-use environments, whereas the conventional districts are more reflective of the existing, primarily automobile-dependent, configuration. 2.2: OFFICIAL ZONING MAP 2.2.1 ESTABLISHMENT AND MAINTENANCE A. Zoning Map: The City Council hereby adopts the City of Beaufort Zoning District Map (hereafter referred to as the "Zoning Map"), which is on file with the Administrator. The Zoning Map is hereby incorporated into this Code by reference as though it were fully include d here. The Zoning Map shall be the final authority as to the status of the current zone classification of land in the City, except in the case of proven errors. B. Districts Established: The City of Beaufort shall be divided into Transect -based, conventional, and overlay districts that implement the Comprehensive Plan. The location and boundaries of the districts in this Article are hereby established, and shall be shown on the Zoning Map . C. Interpretation of District Boundaries: The Administrator shall be initially responsible for interpretations of the official Zoning Map. Where uncertainty exists as to the boundaries of any of the districts shown on the Zoning Map or maps, the Zoning Board of Appeals, upon written application o r upon its own motion, shall determine the location of such boundaries on said Zoning Map or maps. The following rules shall govern the interpretation of District Boundaries: 1. Boundaries indicated as approximately following the centerlines or right -of-way lines of streets, highways, alleys, railways, or public utility easements shall be construed to follow such lines. 2. Boundaries indicated as approximately following plotted lot or tract lines shall be construed as following such lines, whether public or private. 3. Boundaries indicated as approximately following the City limit line shall be construed to follow such City limit line. 4. Boundaries indicated as approximately following the center, mean high water mark, or shoreline of streams, rivers, canals, lakes, marsh areas, or other bodies of water, lowland, or tidal areas, shall be construed to follow such boundaries. 5. For those distances not specifically indicated on the Zoning Map, or in other circumstances not covered by Sections 1. through 4. above, the Zoning Board of Appeals shall interpret the district boundaries. Created: 2023-12-08 08:25:02 [EST] (Supp. No. 1) Page 2 of 73 D. Record Keeping: The original and all revised versions of the Zoning Map shall be certified as such by the signature of the Administrator, and shall be kept on file, in either hardcopy or digital form, in the office of the Department of Planning and Development Services. E. Public Access: Copies of the Zoning Map shall be made available for public inspection in the office of the Department of Planning and Development Services during normal business hours. 2.2.2 CHANGES A. Changes made to zone boundaries or other matters portrayed on the Zoning Map shall be made in accordance with Section 9.16 (Amendments and Rezonings). B. The Administrator shall enter changes onto the Zoning Map within a reasonable period of time after a map amendment is approved by the City Council. Where the ordinance enacting a zone boundary change contains wording explaining or clarifying the location of the new boundary, the Administrator may enter notations on the Zoning Map reflecting the ordinance wording. C. No changes of any nature shall be made to the Zoning Map or matter shown thereon except in conformity with the procedures set forth in this Code. Any unauthorized change of whatever kind by any person or persons shall be considered a violation of this Cod e and punishable as provided by law. D. Regardless of the existence of purported copies of the Zoning Map that may from time to time be made or published, the Zoning Map which shall be located in the Department of Planning and Development Services, shall be the final authority as to the current zoning status of land and water areas, buildings, and other structures in the City, except in the case of proven errors. E. The Administrator shall maintain copies of superseded versions of the Zoning Map for historical reference. F. Where City limit boundaries change by virtue of annexation or some other means, the following provisions shall apply: 1. Areas to be annexed into the incorporated limits of Beaufort shall be assigned zoning classifications by the City Council. 2. In all cases where additions to the City's total area require adjustments in the zoning district boundaries, the adjustment shall be made to the Zoning Map. 3. When reductions are made in the City's total incorporated area the provisions of this Code shall no longer apply to that area. 2.3: TRANSECT-BASED AND CONVENTIONAL DISTRICTS 2.3.1 PURPOSE AND INTENT OF THE TRANSECT APPROACH Most of the zoning districts for the City of Beaufort are ordered and classified according to the "rural -to-urban" Transect (see diagram below). The Transect is a method of classifying the natural and built environments as a continuum of conditions, ranging from natural and rural lands to urban centers. The value of the Transect is that it groups compatible buildings, public spaces, and infrastructure by scale and intensity of use, while still allowing the development of neighborhoods where residents and wo rkers can walk to work, school, and daily errands. For example, a public space at the edge of the city may be a large regional park with hiking trails, while a public space in the City center may be a more intimate square where markets and events take place. Similarly, a Created: 2023-12-08 08:25:02 [EST] (Supp. No. 1) Page 3 of 73 residence near the edge of the City may be on a large lot set back from the street, while a residence in the downtown area may be a condominium in a three - or four-story building. The Transect approach is implemented in Beaufort through different levels of development intensity that range from the T1-Natural Preserve at the low end to the T5-Downtown Core and Urban Center districts at the high end. These Transect zones are also referred to as "form-based districts" because each has detailed provisions for the mix of uses, building design, density, height, street design, the design of parks and open space, parking, and other aspects that make up the City. The Transect zones that guide Beaufort's form-based districts are as follows: 2.3.2 SUMMARY OF TRANSECT-BASED DISTRICTS T1-NATURAL PRESERVE DISTRICT (T1) The T1-Natural Preserve district is intended to preserve areas that contain sensitive habitats, active or passive open spaces and urban parks, cemeteries, and limited agricultural uses. This district typically does not contain buildings, with the exception of small civic buildings, interpretive centers, or supportive recreation facilities. There are no specific development standards listed for this district. T2-RURAL DISTRICT (T2) The T2-Rural district is made up of lands in an open, cultivated, or sparsely settled state. Planning for future development within the City of Beaufort does not include rural areas, and inclusion of the T2 -Rural district here is for illustrative purposes only. There are no development standards listed for this district. Created: 2023-12-08 08:25:03 [EST] (Supp. No. 1) Page 4 of 73 T3-SUBURBAN DISTRICT (T3-S) T3-Suburban district is single-family residential in character, with less development than other Transect -based districts within the city. While almost exclusively residential, civic and park functions are also complementary to the character within this district. T3-NEIGHBORHOOD DISTRICT (T3-N) The T3-Neighborhood district is residential in character, and includes a mixture of residential and civic uses. Residential units are an assortment of sizes and types including cottages, small houses, two - and three-family dwellings, village houses, and cottage courts. Carriage houses, located behind single family homes, and on the interior of lots, may contain studios or other small businesses. Created: 2023-12-08 08:25:03 [EST] (Supp. No. 1) Page 5 of 73 T4-HISTORIC NEIGHBORHOOD DISTRICT (T4-HN) The T4-Historic Neighborhood district is a primarily residential district that encompasses the entire historic district with the exception of a few north-south commercial corridors. It contains houses and residential buildings that are characterized by generous front porches, southern orientation, and historic architectural detailing. A limited number of corner retail buildings historically existed, and continue to exist, in this district. Created: 2023-12-08 08:25:03 [EST] (Supp. No. 1) Page 6 of 73 T4-NEIGHBORHOOD (T4-N) The T4-Neighborhood district is a mixed-use zone of urban residential units and limited commercial development. A wide range of building types exist in the T4 -Neighborhood district, including, but not limited to, apartment buildings, mixed-use buildings, rowhomes, duplexes, corner stores, and both attached and detached single -family housing. A sub-district of this is the T4-Neighborhood Artisan (T4-NA) district. It incorporates more industrial uses, as well, and is applicable in the Depot Road area where industrial uses abut residential areas. Created: 2023-12-08 08:25:03 [EST] (Supp. No. 1) Page 7 of 73 T5-DOWNTOWN CORE DISTRICT (T5-DC) The T5-Downtown Core district consists of higher density, mixed -use buildings that accommodate retail, rowhomes, offices, and apartments. A tight network of streets, including those in Beaufort's historic commercial downtown, allows this district to be a h ighly walkable area. Buildings are set very close to the street in order to define the public realm and allow for visible activity along the streetscape. T5-URBAN CORRIDOR DISTRICT (T5-UC) The T5-Urban Corridor district consists of higher density, mixed -use buildings that accommodate retail, rowhomes, offices, and apartments located along primary thoroughfares. A tight network of streets allows this district to be a highly walkable area. Buildings are set very close to the street in order to define the public realm and allow for visible activity along the streetscape. Created: 2023-12-08 08:25:03 [EST] (Supp. No. 1) Page 8 of 73 2.3.3 SUMMARY OF CONVENTIONAL DISTRICTS REGIONAL MIXED-USE (RMX) The RMX district's intensity accommodates region - and community-serving commercial and business uses, as well as highway-oriented businesses. Development form supports a high-quality commercial character coordinated with a uniform streetscape that enables pedestrian and transit access. Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 9 of 73 LIGHT INDUSTRIAL DISTRICT (LI) The LI district permits office, manufacturing, industrial, and warehousing uses, as well as their supporting uses. Moderate to high intensities are permitted to achieve maximum land utilization that will also accommodate small businesses and start-up or incubator businesses. It also allows for larger industrial parks where appropriate. INSTITUTIONAL & CAMPUS DISTRICT (IC) The IC district supports generally non-residential institutions and employment areas that are designed in a campus-like setting, such as hospitals, universities, research facilities, and offices. It is intended to ensure that these unique institutions are designed to be compatible with their surroundings and the rest of the city. MANUFACTURED HOME PARK DISTRICT (MHP) The MHP district provides a sound and healthy residential environment that is sufficient to meet the needs of inhabitants living in manufactured homes, to protect manufactured home parks from encroachment by incompatible uses, and to encourage the consolidation of manufactured homes into manufactured home parks. MILITARY RESERVATION DISTRICT (MR) The MR district is applied to existing military bases and Department of Defense lands, and provides for military facilities and all supporting activities, such as housing, offices, and services that are on base land, even though they would otherwise be considered separate uses. Military property is under jurisdiction of the federal government. Recommendations and standards for this district are not included since these lands are federally owned, and are typically not subject to city regulations. - 2: MAP AND DISTRICTS 2.4: DISTRICT DEVELOPMENT STANDARDS Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 10 of 73 2.4: DISTRICT DEVELOPMENT STANDARDS 2.4.1 TRANSECT-BASED DISTRICT STANDARDS DISTRICT T3-S T3-N T4-HN T4-N T5-DC T5-UC A. LOT CONFIGURATION 1. Lot Width at Front Setback 75 60ft min; for waterfront lots see Section 2.5.4 40 ft min, 60 ft min in the Hundred Pines neighborhood 40 ft min, 60 ft min in The Point n/a n/a n/a 2. Lot Size 69,000 sf min; for waterfront lots see Section 2.5.4 4,000 sf min; 3,000 sf min for alley- served lots 4,000 sf min; 6,000 sf min in The Point n/a n/a n/a 3. Maximum Lot Coverage1 3045% of lot area 45% of lot area 55% of lot area 70% of lot area 100% 1090% 4. Frontage Build-Out2 n/a n/a 75% max 60% min; 85% max 75% min 7560% min 1 This percentage indicates maximum lot coverage by roofs; total impervious coverage may be an additional 10%. Parcels may also be subject to Section 8.3 (Stormwater). 2 See Section 2.5.1 B. for additional frontage build-out standards. 3. Lots located in the historic district, will be subject to the Historic Review Board approval process of 9.9.2 D. B. PRIMARY BUILDING PLACEMENT 1. Front Setback; for infill lots also see Section 2.5.2 20 ft min 15 ft min Average Prevailing Setback on Block 0 ft min 0 ft min 0 ft min No max 30 ft max3 15 ft max Max. Prevailing Setback on Block 15 ft max 2. Side Setback— Corner/Alley 15 ft min 6 ft min 5 ft min 0 ft min 0 ft min 0 ft min No max No max No max 10 ft max 15 ft max 15 ft max Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 11 of 73 3. Side Setback— Interior 10 ft min 6 ft min 6 ft min, 10 ft min in The Point 5 ft min, or 0 ft if attached 0 ft min 0 ft min 4. Rear Setback4 15 ft min 15 ft min 15 ft min 10 ft min 0 ft min 5 ft min 5. Rear Setback from Alley4 n/a 0 ft 0 ft 0 ft 0 ft 0 ft 6. Attached Garage/Carport Setback (from front facade)5, 6 5 ft min 5 ft min Attached garages shall only be accessed via an alley; garage doors shall not face the street C. ACCESSORY BUILDING PLACEMENT—See Section 3.11 for additional requirements 1. Front Setback Accessory structures shall be located behind the front facade of the primary structure, except as provided for in Section 2.5.4 (Waterfront Lots) and Section 4.5.3 (Carriage House); see item 6 below for setback for detached garage doors 2. Side Setback— Corner/Alley5 5 ft min 5 ft min 5 ft min 3 ft min 0 ft min 0 ft min 3. Side Setback— Interior 5 ft min 5 ft min 5 ft min 5 ft min 0 ft min 0 ft min 4. Rear Setback4 5 ft min 5 ft min 5 ft min 5 ft min 0 ft min 0 ft min 5. Rear Setback from Alley4 3 ft min 3 ft min 3 ft min 3 ft min 3 ft min 3 ft min 6. Detached Garage Door/Carport Setback (from front facade)5 5 ft min 205 ft min 205 ft min 20 ft min Shall be located behind primary building and accessed via alley or side street7 3 When lot width is 75 ft or greater, there is no maximum front setback. 4 Garage doors shall be 15 ft min from alley centerline. 5 In addition to the setback requirements listed above, garage doors/carports which face a public right-of-way, except for rear alleys, shall be set back a minimum of 20 ft from that right-of-way. 6 The Battery Shores and Islands of Beaufort neighborhoods are exempt from this standard when garage doors do not face a public right-of-way. In the Jericho Woods neighborhood, carports are exempt from this standard. 7 Also see Section 2.5.7(Street Access Standards). D. BUILDING FORM 1. Primary Building Height—See Section 2.6 No min No min No min 2 stories min8 2 stories min 2 stories min8 2.5 stories max 2.5 stories max 3 stories max 4 stories max; 3.5 3 stories max at 5 stories max; 3.5 Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 12 of 73 stories max in & fronting Historic District & interior lots along Allison Rd. property line, see 2.6.1.G stories max in & fronting Historic District 2. Accessory Building Height 2 stories or 30 ft max 2 stories or 30 ft max 2 stories or 30 ft max 2 stories or 30 ft max 2 stories max or 30 ft max 2 stories max or 30 ft max 3. Building Width at Frontage n/a n/a n/a 100 ft max 100 ft max9 160 ft max9 8 Two stories are only required at significant intersections, in accordance with Section 2.6.3 and the Street Hierarchy Diagram in Appendix C.3. 9 Buildings exceeding this maximum shall comply with the Large Footprint Building standards in Section 4.5.10. E. PARKING PAD LOCATION—There are no interior side setbacks for parking unless buffers are required per Section 5.5. See Section 2.5.8 for additional provisions 1. Front Setback There are no parking setbacks, however, driveways shall be located to the side of the lot/primary structure except on waterfront lots meeting the conditions stated in 2.5.4. 40 ft min 40 ft min 40 ft min 40 ft min 2. Side Setback— Corner 5 ft min 15 ft min 5 ft min 5 ft min 3. Rear Setback 5 ft min 5 ft min 0 ft min 0 ft min LOT CONFIGURATION (2.4.1.A) Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 13 of 73 BUILDING PLACEMENT (2.4.1.B—C) BUILDING FORM (2.4.1.D) PARKING LOCATION (2.4.1.E) 2.4.2 CONVENTIONAL DISTRICT STANDARDS General standards for development in the Regional Mixed -Use (RMX), Light Industrial (LI), Institutional & Campus (IC), and Manufactured Home Park (MH) districts are outlined in the table below. Land designated as Military Reservation (MR) district is under the jurisdiction of the federal government; the City has no development standards for these lands. DISTRICT RMX IC LI MH MR A. RESIDENTIAL DENSITY1 1. Residential Units/Acre 30 units/acre max 30 units/acre max n/a 7 units/acre max Exempt B. LOT SIZE & BUILDING FORM Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 14 of 73 1. Minimum Lot Width2 60 ft min 50 ft min 50 ft min 150 ft min Exempt 2. Lot Size2 6,000 sf min 5,000 sf min 10,000 sf min 5 acres 3. Impervious Surface Coverage 65% max 65% max N/A N/A 4. Building Height 4 stories 4 stories 4 stories3 2 stories 1 Measured as gross density—calculation of acreage includes land occupied by rights-of-way, parks, open space, and other non-residential uses. 2 Where properties are accessed via a rear alley or lane, this standard may be decreased by 25%. 3 In industrial parks larger than 50 acres, the height limit is permitted to increase to 10 stories unless otherwise restricted by the AICUZ. C. PRINCIPAL BUILDING PLACEMENT4 1. Front Set- back - Primary 10 ft min 10 ft min 15 ft min 25 ft min Exempt 60 ft max5 Max setback shall not exceed average max setback on same side of block; build-to line of adjacent T- zone shall also be considered n/a n/a 2. Side Setback - Corner 10 ft min 5 ft min; max setback shall not exceed average setback on same side of block; build-to line of adjacent T- zone shall also be considered 15 ft min 15 ft min 3. Side Setback - Interior 10 ft min; 15 ft min when abutting any Transect- based district 10 ft min; 25 ft min when abutting T3 districts 0 ft min 25 ft min when abutting other districts 15 ft min 4. Rear Setback 15 ft min 25 ft min 10 ft min 25 ft min when 15 ft min Created: 2023-12-08 08:25:04 [EST] (Supp. No. 1) Page 15 of 73 abutting other districts 4 See Section 5.5.1 for additional buffer requirements. 5 When corridor buffer requirements - Section 5.5.1 B. - are required, the maximum front setback may be increased to no greater than 50 feet behind the buffer. D. ACCESSORY BUILDING PLACEMENT6 1. Side Setback - Corner 10 ft min 10 ft min 10 ft min 10 ft min Exempt 2. Side Setback - Interior 5 ft min 5 ft min 0 ft min 25 ft min when abutting other districts 5 ft min 3. Rear Setback 5 ft min 5 ft min 10 ft min 25 ft min when abutting other districts 5 ft min 6 Also see Accessory Uses & Structures in Section 3.11 E. PARKING LOCATION 1. Parking Location Parking areas and drive aisles shall be located in the side or rear yard whenever possible. Parking areas and drive aisles shall not be located within the front setback, but may be placed in front of the building. However head-in rows of parking shall not be permitted to front Primary Streets. Diagonal rows of parking shall not front Primary Streets except as part of a slip or frontage-road design, or when there are less than 10 consecutive spaces. Where 10 or more parking spaces are required, the majority of the parking shall be located in the side or rear of the building. n/a n/a Exempt 2.5: GENERAL LOT STANDARDS Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 16 of 73 2.5.1 BUILDING PLACEMENT AND ORIENTATION A. Frontage and Orientation on Street: All buildings shall front a street right-of-way, and have a usable entrance on the Primary Frontage with the following conditions and exceptions: 1. Multi-Building Sites: a. Buildings shall be located to break up the site into a series of smaller blocks defined by streets and pedestrian walkways, and to frame and enclose parking areas, outdoor dining areas, and/or gathering spaces for pedestrians between buildings. b. Perimeter buildings and outparcels shall be configured and located to define street edges, development entry points, and spaces for gathering between buildings. c. Perimeter buildings shall be oriented so that the primary facade(s) faces a public street and has a usable entry on that street. Buildings that are interior to a lot that has buildings that otherwise meet the frontage requirement may have entrances that d o not face the Primary Frontage. Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 17 of 73 2. Live/Work Buildings: Where such buildings are permitted, the entrance to the commercial space shall face the Primary Frontage. However, the entrance to the residential space may be located on the side or rear. 3. Utility and Conservation Lots: Lots platted for the sole purposes of being sites for public utilities (e.g., water, sewer, electric, stormwater) or as conservation areas shall not be required to abut a dedicated public street. Adequate access by easement shall be provided. Buildings as sociated with utilities shall meet the building standards and guidelines of the zoning district. 4. Lots May Front on Civic or Open Space: Lots shall be permitted to front on a civic or open space as defined in Section 7.4.3. B. Frontage Build-Out: 1. Facades shall be built parallel to the principal frontage line or to the tangent of a curved principal frontage line, and along a minimum percentage of the frontage width at the setback, as specified in Sections 2.4.1 A.4. and Section 4.4 (Private Frontag e Type). a. Exceptions: i. Exceptions may be granted by the Administrator where the parcel has an irregular configuration, utility easements or legal constraints which prevent compliance, or if building is sited to take advantage of specific topographical and natural characteristics. ii. This provision does not apply in T3-S, IC or LI zoning districts. 2. Front facades shall front public streets or rights -of-way. In the case where buildings front multiple streets, or desire to have entrances facing the parking lot, multiple front facades may be designed. 3. For parcels that may contain multiple structures in different phases, an overall Illustrative Sketch, showing proposed building locations and site circulation, shall be prepared to ensure that the frontage build-out is being met as closely as possible. Th ese parcels will not be required to be built out all at once, and may be phased over time. The Illustrative Sketch is subject to future modifications as long as the intent of this standard continues to be met —this will be evaluated by the Design Review Authority as each individual project phases are designed. 4. Pedestrian-use areas (such as plazas, courtyards, and sidewalk cafes) within the minimum and maximum front setbacks are exempt from the frontage build -out when all of the following conditions are met: Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 18 of 73 a. The existing sidewalk is less than 8' wide. b. The primary facade is within 10' of the build-to line. c. One of the appropriate frontage types (see Section 4.4) is utilized. 5. Where rear access is not possible, driveways are also exempt from this requirement, and their width may be subtracted from the total lot width to determine the build -out percentage. C. Corner Lots: 1. Buildings located at street intersections shall place the primary building, or part of the building, at the corner; however, gathering spaces may be appropriate at corners of larger developments. 2. Parking shall not be located between the building and the Primary Street(s). D. Pedestrian Entries from Frontage Line: Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 19 of 73 1. Buildings shall have their principal pedestrian entrances on a frontage line. 2. All buildings with shared entrances shall be oriented so that the primary entrance(s) face(s) the street. 3. In the case of corner lots, the primary entrance(s) shall face the street from which the building derives its street address. 4. In the T4 and T5 zones, blank facades are not permitted. Multiple pedestrian entrances for public access shall be provided every 50 feet, or more frequently. The Design Review Authority may modify the spacing of the entrances based on the amount of glazin g, interior layout, and general design of the structure. E. Frontage Types: The private frontage of the building shall comply with the standards laid out in Section 4.4 (Private Frontage Type). F. Building Types: More specific standards may apply based on a specific building type (Section 4.5). 2.5.2 INFILL LOT STANDARDS A. The minimum setbacks required may be reduced for infill lots where existing development on the block does not match the current standards in Section 2.4.1. Setbacks for such lots shall either match an existing adjacent setback or use the calculated averag e setback of the adjacent lots. B. Special Conditions: 1. Islands of Beaufort neighborhood: Side Setback for T3 -S is reduced to 10 feet. 2. Battery Shores neighborhood: Side Setback for T3 -S is reduced to 10 feet. 3. Battery Point neighborhood: Rear Setback for T3 -N is reduced to 10 feet. 4. T3-N parcels between Fuller Parkway and Ribaut Road, bound by Stuart Street on the North and Barnwell Avenue on the south: a. For lots with frontage onto both Fuller Parkway and Ribaut Road, subdivision shall not add new driveways onto Ribaut Road. No new lot may be created without either: i. A new rear lane created to provide rear access to parcels fronting Ribaut Road; or Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 20 of 73 ii. An access easement from Fuller Street. 2.5.3 WATER-ORIENTED FACILITIES Water-oriented facilities such as docks, marinas, boat houses, etc., shall be allowed to encroach into required setback areas along shorelines and into rivers, lakes, streams and other waterways. See Section 3.7.1 F. and 8.2 for more details on these structures and facilities. 2.5.4 WATERFRONT LOTS A. Attached Garages: Notwithstanding the requirements for Attached Garages in Section 2.4.1 CB.6., such structures associated with residential dwellings may be placed in front of the principal building elevation, if all of the following conditions are met: 1. The upper level(s) shall contain habitable space. 2. The frontage requirement in Section 4.4 is met. B. Accessory Structures: Notwithstanding the requirements for Accessory Structures in Section 2.4.1 C.6., such structures associated with residential dwellings may be placed in front of the principal building elevation, if all of the following conditions are met: 1. Structures shall meet the typical front and/or side setback requirements. 2. Garage doors shall be oriented perpendicular to the public right -of-way to minimize visibility. 3. Structures shall be compatible with the primary dwelling unit in architectural details including color, siding, roof pitch, window detailing, siding materials, roof materials and foundation. C. Critical Area Buffer: As required by Section 8.2. D. Special Lot Requirements: 1. Specific to T3-S - Lot Width, Depth, and Area: a. The minimum lot width at the setback line for waterfront lots shall be 100 feet. b. The minimum lot depth for waterfront lots shall be 125 feet. 2. Specific to T3-N: The front setback requirement for waterfront lots may be met with an accessory structure. 3. Subdivision of Waterfront Lots: Waterfront lots that exceed the minimum lot depth requirements, and are larger than 350 feet deep and 18,000 square feet, may be subdivided into two lots - one fronting the water and one fronting the right -of-way provided both lots conform with the applicable requirements of this Code. In such instances, the following standards apply: a. Lot Access: Access to the water-fronting lot shall be maintained through a minimum 20 - foot access easement or right-of-way across the street-fronting lot. Alternatively, access may be provided via a side street, or an alley through the entire block. Access shall meet the minimum fire apparatus access road requirements as outlined in the International Fire Code. b. Lot Dimensions: The new lot(s) fronting the street shall meet the standards for T3 -N. Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 21 of 73 2.5.5 IRREGULAR LOT CONDITIONS A. Irregular Lot Lines: Generally, side lot lines shall be perpendicular or radial to the street right -of-way, and rear lines should be approximately parallel to fronting right -of-way lines. Irregularly shaped lots shall be permitted at the discretion of the Administrator when u nique site conditions exist. B. Irregular Lot Setbacks: The location of required front, side, and rear yards (or setbacks) on irregularly shaped lots shall be determined by the Administrator, based on the prevailing spacing of buildings on the adjacent parcels. Where questions arise as to appropriateness, the applicant may be requested to provide additional design information. C. Double- and Triple-Frontage Lots: On lots with two street frontages, not located at a corner, or with three frontages and located at a corner, the front setback will apply to both the street that the building derives its address from, in addition to the opposite, parallel street. The setb acks for accessory structures will be reduced to half the front setback, however the provisions for garage doors in 2.4.1.C.6 still apply. This does not apply to lots located on a corner with a rear alley. D. Flag Lots: 1. The front setback on flag lots shall be measured from the front property line within the main building site as opposed to the property line adjoining the public right -of-way. 2. Flag lots may be permitted by the Metropolitan Planning Commission in major subdivisions as part of the subdivision review process, if the lot has an access strip with a minimum width of 20' serving the main building site of the property. 23. Flag lots shall be permitted, using the process for Administrative Adjustment (Section 9.12), or by the Planning Commission for major subdivision, if all of the following conditions apply: a. Connectivity and circulation via a network of streets, alleys, pathways, etc. will be maintained. b. There is no reasonable alternative, due to extreme topographic conditions or other physical condition. c. The lot has an access strip with a minimum width of 20 feet serving the main building site of the property. The front setback on flag lots shall be measured from the front property Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 22 of 73 line within the main building site, as opposed to the property line adjoining the public right - of-way. d. For waterfront lots, standards from Section 2.5.4 shall also be met. 34. Flag lot access shall meet the minimum fire apparatus access road requirements as outlined in the International Fire Code. 2.5.6 ENCROACHMENTS The features listed below shall be permitted to encroach into a required yard or right -of-way, as applicable. A. Encroachments over Sidewalks: With approval of the City, county or SCDOT (whichever has authority over a street), awnings, arcades, canopies, and galleries (See Section 4.4), may encroach over the sidewalk to within 2 feet of the curb, but they shall provide a vertical clearance of at least 8 feet from any sidewalk. B. Upper Story Encroachments: Bay windows, balconies, and similar features projecting from the principal building may encroach up to 50% of the depth of the front and street side setback. With approval of the City, county or SCDOT (whichever has authority over a street), upper -story balconies or bay windows may encroach over the right-of-way a maximum of 3 feet, but they shall provide a vertical clearance of at least 8 feet from any sidewalk. C. Lower Story Encroachments: Cornices, eave overhangs, chimneys, flues, bay windows, and similar projections (including gutters) may encroach up to 2 feet into any required yard. D. Covered Porches: Covered porches may encroach a maximum of 8 feet into any required front yard or street side yard setback and to within 5 feet of any interior side or rear yard property line. E. Uncovered Porches, Decks, Patios, Steps and Stairs: Uncovered and unenclosed porches, decks, patios, steps and stairs, and other similar features may encroach to within 5 feet of any interior side and rear property line. Steps and stairs may encroach up to 100% of the depth of any required street yard setback, but may not encroach upon any public sidewalk. F. Walkways, and Driveways: Uncovered and unenclosed walkways, and driveways may encroach up to 100% of the depth of any required setback, unless a buffer, per Section 5.5.1, is required. G. Handicapped Ramps: Ramps for handicap accessibility and fire escapes that are required by the "Accessibility Code" may encroach into any required yard but may not be closer to any property line than 5 feet. Such features shall not be located in a front yard if it is possibl e to accommodate them in a side or rear yard. H. Fences and Garden Walls: Fences and garden/yard walls may encroach into required setbacks. The support structures for fences shall be located on the inside of the fence, and no fence, wall or hedge shall exceed the following dimensions: 1. Front or Street Side Setback: Four feet in height, with the following exceptions: a. On T3 lots that front Ribaut Road, fences may be permitted to be 7 feet in height on the condition that such fences are set back from the front property line 1 foot for every 1 foot increase in height above 4 feet. b. In the LI District, parcels fronting a Primary Street may have fences or walls up to 6 feet in height. Parcels fronting all other streets may be up to 10 feet in height. c. Electric fences are not permitted to encroach into any front or street side setbacks. 2. Interior Side or Rear Setback of a Transect -Based District: 6 feet in height. Formatted: List 2 Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 23 of 73 3. Interior Side or Rear Setback of a Conventional District: 8 feet in height. 4. Interior Side or Rear Setback of LI District: 10 feet in height. I. Mailboxes: Mailboxes may encroach into a front setback area. The following standards apply: 1. In the Historic District, freestanding mailboxes are not permitted. Mailboxes shall be attached to a fence or the structure itself. 2. When grouped or ganged mailboxes are required as part of a new development, a structure shall be provided to house the individual units. The structure may encroach into a typical front or side setback. The structure shall be included in the site plan and the design shall be approved by the appropriate Design Review Body. J. HVAC: HVAC units may encroach up to 3 feet into a required side or rear setback. 2.5.7 STREET ACCESS STANDARDS A. Access to Lots from Alleys/Rear Lanes: 1. Lots served by alleys shall access garages and/or off -street parking areas from the alley, and shall not have driveways in front or corner side yard areas. 2. Requirements for alley locations can be found in Section 7.2.3. B. Avoid Double-Frontage and Reverse-Frontage Lots: 1. New double-frontage and/or reverse-frontage lots (lots with street frontage on opposite sides of the lot) are prohibited. The Design Review Authority may permit them on a case -by-cases basis if they are unavoidable due to existing topographical or environ mental conditions. 2. To encourage the subdivision of existing double -frontage residential lots into two single -frontage residential lots, the minimum lot size for such lots may be reduced to 75% of the minimum lot size for the district, as established in Section 2.4. 2.5.8 EXCEPTIONS TO SECTION 2.4.1 E.—PARKING LOCATION A. The provisions shall not apply to cars parked on front -loaded driveways. B. Where lot depth is less than 60' deep, the Administrator shall evaluate this requirement on a case -by- case basis. In no case shall parking be located in front of a building in T4 and T5 zoning districts. C. Where lots have frontage on more than one Primary Street and build -out on one of the streets is planned to be phased, per Section 2.5.1 B.3., parking may be permitted within the parking setback, provided it doesn't prevent or preclude future build -out of the overall master plan for the parcel. Screening is still required per Section 5.7.8. 2.5.9 LOT DIVERSITY: a. Mix of housing. A mix of permitted housing types shall be included in any individual development plan, to the extent reasonably feasible, depending on the size of the parcel. In order to promote such variety, the following minimum standards shall be met: i. A minimum of two housing diversity types shall be required in residential developments containing 5 acres or more, including such plans that are part of a phased overall development; Formatted: Font: 12 pt, Bold Formatted: Font: 12 pt, Bold, Not Italic Formatted: Font: 12 pt, Bold Formatted: Indent: Left: 0.5" Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 24 of 73 ii. A minimum of three housing diversity types shall be required in residential developments containing more than 10 acres, including such plans that are part of a phased overall development; iii. A minimum of four housing diversity types shall be required in residential developments containing more than 20 acres, including such plans that are part of a phased overall development. b. To the maximum extent feasible, housing types, block dimensions, garage placement, lot sizes and lot dimensions shall be significantly and substantially varied to avoid repetitive rows of housing and monotonous streetscapes. For example, providing distinct single-family detached dwellings or two-family dwellings on larger lots and on corners and providing small lot single -family dwellings on smaller lots abutting common open spaces fronting on streets are methods that accomplish the lot diversity requiremen ts set forth in this subsection i. In addition, diversity and density is to be spread within developments in a harmonious fashion and not located in one area. Disconnected areas of density or different lot and uses will not be permitted. c. The following list provides housing diversity types available to satisfy this Lot Diversity requirement. i. Single-family detached dwellings with rear loaded garages. ii. Single-family detached dwellings with front or side loaded garages. iii. Small lot single-family detached dwellings (i.e. lots containing less than 4,000 square feet or with lot frontages of 40 feet or less) may be used to satisfy the lot diversity requirements if: 1) there is a difference of at least 2,000 square feet between the average lot size for small lot single-family detached dwellings (insert that average size) and 2) the average lot size for single -family detached dwellings with front or side loaded garages iv. Two-family dwellings and Single-family attached dwellings. v. Townhouses and rowhouses. vi. Mixed-use buildings. vii. Multi-family dwellings containing no more than three to four units per building; viii. Multi-family dwellings containing five to seven units per building. ix. Multi-family dwellings containing more than seven units per building (limited to 12 dwelling units per building). x. Commercial buildings, including liber buildings, and large footprint buildings. xi. A mixture of lot sizes is provided within one block (i.e. 40 feet wide lots with 80 feet wide lots), on at least 30 percent of the lots. xii. Civic Buildings 2.6: HEIGHT Building heights by district, as specified in Section 2.4.1, shall be determined according to the provisions below. 2.6.1 MEASUREMENT OF BUILDING HEIGHT A. Building height is measured as the number of stories (syn. floors) in a building. A story is a habitable level in a building of no more than 15 feet in height from finished floor to finished ceiling. Each full story above the ground floor shall be a minimum of 8 feet from floor to ceiling. B. Where a maximum height is also provided in feet, that height shall be taken from the average sidewalk or site grade at the front facade of the building to the mean roof height or top of the parapet. Where the building is located in a flood zone, the heigh t shall be taken from the first finished floor above the base flood elevation. Formatted: Indent: Left: 0.5" Formatted: Indent: Left: 0.5" Formatted: Indent: Left: 0.5" Formatted: List Paragraph, Numbered + Level: 1 + Numbering Style: i, ii, iii, … + Start at: 1 + Alignment: Left + Aligned at: 0.25" + Indent at: 0.75" Formatted: Indent: First line: 0.25" Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 25 of 73 C. Under-roof areas with dormers shall be counted as half -stories. D. Mezzanines shall be counted as stories, unless they are within a floor -to-ceiling volume that is no more than 15 feet in height. E. Unoccupied attics less than 7 feet in height to the ridge beam or collar tie (whichever is lower) and raised basements less than 6 feet above the adjacent grade shall not be calculated as stories. F. Certain buildings (such as gymnasiums, religious institutions, theatres, etc.) may require finished floor - to-ceiling heights greater than 15 feet. In such instances, the number of stories shall be calculated as the finished floor-to-ceiling height (in feet) divided by 15. Any fractions of a story shall be rounded up to the next whole number, with the following exception: 1. Specific to T5-UC: The maximum first floor height for such buildings shall be 24'. G. Specific to T5-DC: The maximum height at the property line shall be 3 stories, and the maximum height 15 feet behind the property line, or front line of the building, shall be 4 stories. 2.6.2 BUILDING HEIGHT ABOVE GRADE A. General to All Zones: 1. 1. Freeboard: In addition to the standards listed below, where a parcel is located in a flood-hazard zone, the minimum elevation above grade is 1 foot above base flood elevation. . In special flood hazard areas (zones A, AE, AH, AO, A1-30, V and VE) and other areas with the potential of flooding (such as x and shaded x zones) where base flood elevation data has been provided by FEMA Flood Insurance Maps, the following provisions are required: New Construction, substantial improvement, or an addition, including an addition to a historic structure, the footprint of which is over thirty-three (33) percent of the footprint of existing structure, shall have the lowest floor elevated to the most restrictive of the design elevation of 13 feet or the base flood elevation plus one foot of freeboard. No basements are permitted. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with national flood insurance program. 2. Exception: Commercial buildings that have been floodproofed, per ASCE Section 24 or most recent version, do not have to be elevated above grade. B. Specific to T3 Zones: 1. If the finished floor of new single-family residential construction will be lower than the average grade along any property line, the finished floor must be elevated a minimum of 18" above finished grade adjacent to the building exterior. 2. The finished ground floor elevation for 2- and 3-unit buildings shall be elevated a minimum of 2 feet above the average adjacent sidewalk, or adjacent street grade where no sidewalk is present. 3. If a single-family residence in a T3 zone is developed as part of an Alternative Development Pattern (Section 2.8), it shall be elevated a minimum of 18" above the average adjacent sidewalk grade or adjacent street grade where no sidewalk is present. C. Specific to T4 Zones: 1. The finished ground floor height for residential structures shall be elevated a minimum of 2 feet above the average adjacent sidewalk grade or adjacent street grade where no sidewalk is Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 26 of 73 present. Apartment Houses are permitted to be a minimum of 18" above grade, per Section 4.5.7. 2. The ground floor height of single-family residential structures shall be a minimum of 9 feet from finished floor to ceiling. 3. The ground floor height of multi-family residential structures shall be a minimum of 10 feet from finished floor to ceiling. 4. The ground floor height of commercial buildings shall be a minimum of 11 feet from finished floor to ceiling. 5. Each full story above the ground floor shall be a minimum of 8 feet from floor to ceiling. D. Specific to T5 Zones: 1. The finished ground floor height for residential structures shall be elevated a minimum of 3 feet above the average adjacent sidewalk grade. Apartment Houses are permitted to be a minimum of 18" above grade, per Section 4.5.7. 2. The ground floor height of residential structures shall be a minimum of 10 feet from finished floor to ceiling. 3. The ground floor height of single-story commercial buildings shall be a minimum of 14 feet from finished floor to ceiling. 4. The ground floor height of multi-story commercial buildings shall be a minimum of 12 feet from finished floor to ceiling. 5. In T5-DC, the Historic Review Board may permit deviations from the minimum height requirements listed above if doing so would allow a structure to be more compatible with the surrounding context. 6. Each full story above the ground floor shall be a minimum of 8 feet from floor to ceiling. 2.6.3 TWO-STORY HEIGHT REQUIREMENTS Specific to Zones T4-N and T5-UC: Two-story buildings are required within 250 feet of any Significant Intersection (see Street Hierarchy Diagram in Appendix C.3) as measured from the centerline of the intersection. Any parcel that is partially within the 250-foot radius will be required to comply with the two-story height requirements. Where a two-story minimum building height is required, the following configurations are permitted in addition to a typical two-story building with habitable space on each level: A. Two-Story Mass: This can be an open, double-height structure with a minimum building height of 24 feet. The second floor does not need to be built out or habitable. B. Mezzanine: The intent of mezzanines is to provide upper -level activity along street facades. Mezzanines shall meet the following conditions: 1. All buildings shall include a minimum massing of two stories extending fully along all street - fronting facades and any facade that is visible from a corner. If a building cannot meet this standard through the use of a mezzanine, then the mezzanine will no t be permitted to fulfill the two-story requirement. 2. Mezzanines shall be located on the Primary Facade(s) of a building. 3. A mezzanine shall be designed as usable primary interior floor space, not storage or other secondary, mechanical, or service functions. Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 27 of 73 4. All mezzanine floor space shall be located in direct contact with street -fronting second-floor windows and is required to meet all of the window transparency requirements of a second floor. 5. When being used to satisfy a two-story building height requirement, a mezzanine level shall meet all ceiling height standards of a second floor. 2.6.4 DIMENSIONAL HEIGHT STANDARDS Height requirements for signs, lighting, landscape screens, and all other structures or objects for which a dimensional height requirement is established by this Code shall be measured as the vertical distance from the average sidewalk or site grade at the structure or object's foundation to its highest point. 2.6.5 ITEMS NOT INCLUDED IN HEIGHT CALCULATIONS The height limitations of this Code shall not apply to church spires, belfries, cupolas and domes not intended for human occupancy, monuments, water towers, mechanical penthouses (provided they are set back 20 feet from the front elevation), observation towers, transmission towers, chimneys, smokestacks, conveyors, flagpoles, masts and antennas (provided evidence from appropriate authorities is submitted to the effect that such building or buildings will not interfere with any airport zones or flight patter ns). The Design Review Authority may adjust the 20-foot setback on a case-by-case basis 2.6.6 HEIGHT TRANSITION. Any portion of a building located within the T -4, T-4N, T5-UC, or RMX District, shall have a maximum height no greater than the maximum height allowed in the adjacent zoning district for a 75 foot distance beginning at the zone district boundary line. Where a street separates the zoning districts, the 75 foot distance measurement shall be from the street right-of-way line opposite the T-4, T-4N, T5-UC, or RMX District Formatted: Font: Bold Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 28 of 73 2.7: OVERLAY DISTRICT STANDARDS Certain areas of the City may fall into one or more of the following overlay districts. When a property is newly assigned, reassigned, or annexed into one of these districts, the owner shall be required to formally acknowledge that they are within such district by signing a notification form, provided by the City and recorded at the Beaufort County Register of Deeds Office. Formatted: Heading 2 Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 29 of 73 2.7.1 BEAUFORT HISTORIC DISTRICT (HD) OVERLAY A. Purpose: The purpose of the Beaufort Historic District is to promote the educational, cultural, and general welfare of the public through the preservation, protection, and enhancement of the old, historic or architecturally significant structures and areas of the City and to maintain such structures and areas as visible reminders of the history and cultural heritage of the City, the state, and the nation. The Historic District is a pedestrian-oriented area. B. Applicability: Properties within the Beaufort Historic District are subject to specific standards found in this section, and to the review procedures of the Historic District Review Board as described in Section 10.7. C. Beaufort Historic District Designated: For the purpose of this section, the Beaufort Historic District is hereby established. The boundaries of this district shall be designated on the official Zoning Map of the City of Beaufort. The boundaries of the Beaufort Historic District and the Beaufort National Historic Landmark District are the same with the following clarifications/exceptions: 1. Where boundaries are designated at specific roads, the centerlines of the rights-of-way of those roads shall be deemed said boundaries. 2. The east and south boundaries of the district are established at the Beaufort River. These boundaries are established at the parcel lines, seawalls, or at mean high water mark, whichever extends further from the high ground. 3. Structures attached to the high ground are deemed to lie within the district and shall be reviewed in entirety in accordance with the provisions of this section. Created: 2023-12-08 08:25:05 [EST] (Supp. No. 1) Page 30 of 73 D. Subdistricts Established: The Beaufort Historic District shall be composed of 2 subdistricts identified as the Beaufort Preservation Neighborhood (BPN) and the Beaufort Conservation Neighborhood (BCN). There may be established one or more of each subdistrict within the Beaufort Historic District, provided that all such districts shall consist of at least five acres of contiguous land. The boundaries of these subdistricts shall be designated on the official Zoning Map of the City of Beaufort. Where the term Beaufort Historic District (or a similar reference, such as "historic district") is used in this section or in any supplementary materials, it shall apply to both subdistricts. However, where there is a specific reference to a subdistrict, that specific reference shall apply and supersede any reference to the Beaufort Historic District. E. Trash and Recycling Screening: All private trash and recycling receptacles shall be hidden or screened from view. Unscreened facilities shall come into compliance with the provisions of this section within 18 months of adoption of this Code. F. Exemptions: 1. The Bladen Street Redevelopment District overlay zone is exempted from Historic District Overlay standards (See Section 2.7.3 F.). 2. Routine maintenance and repair of any of the existing features of a structure that does not involve a change in design, type of materials, or outward appearance shall be exempt from the review and approval requirements of this section. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 31 of 73 2.7.2 RETAIL FRONTAGE OVERLAY A. Purpose and Intent: In certain districts, it is desirable to maintain a residential character while permitting mixed uses to occur in buildings that front designated streets. B. Certain Commercial Permitted: Where a block face is designated on the Zoning Map as a retail frontage overlay, the building with direct access to the designated fronting street is permitted to be occupied by certain additional commercial uses, as indicated in the Table of Permitted Uses in Section 3.2. C. Designation: Retail frontage overlays are designated on the Zoning Map by a dashed line, as indicated in the map key. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 32 of 73 2.7.3 REDEVELOPMENT DISTRICT OVERLAYS A. Purpose and Intent: The City hereby finds that it is necessary to create certain districts to encourage redevelopment in specific areas. These districts are based upon traditional standards for City buildings, derived from the existing conditions in the City and from a number of sources in planning literature - See Appendix B.1.1. B. Applicability: All parcels designated "redevelopment district" as indicated on the Zoning Map shall be subject to these provisions. C. Application of Standards: The majority of standards for the existing Redevelopment Districts - Boundary Street and Bladen Street - have been incorporated into the body of the Code. However, where special standards apply for the district, they are listed in this section. In the case of conflict between the standards set forth in the redevelopment districts and any other local land development regulation, these standards shall apply. D. Administration: Interpretation of all standards in the redevelopment districts - both architectural and streetscape standards - shall be the responsibility of the Administrator (syn. City Architect). See Section 9.8.2 5.b. for the approval and appeal processes. E. Parking Requirements: 1. Parcels ½ acre and smaller: There are no parking requirements. 2. Parcels greater than ½ acre: one parking space for every 1,000 square feet of leasable or saleable building area is required. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 33 of 73 3. Location: These parking spaces may be located either on-site, on-street (along property frontage and/or directly across the street), in shared parking situations, or in any public parking facility, the closest outside edge of which facility is located no more than 500 feet from the entry to the proposed building. Documentation establishing the legal right for the applicant to use or share parking spaces shall be provided. 4. Parking Stall Sizes: Head-in or diagonal spaces shall be a minimum of 9 feet x 18 feet. Parallel parking spaces shall be a minimum of 7 feet x 20 feet. 5. Drive Aisle Widths: Drive aisles in parking lots shall be 22 feet wide for two-way circulation and to provide adequate backup space for 90-degree head- in parking. Diagonal parking and parallel parking spaces may be accessed with one-way, 10 foot wide drive aisles. All parking lot dimensions are at the discretion of the Fire Marshal, based on evaluation of adequate fire apparatus access and industry-approved standard. F. Specific to the Bladen Street Redevelopment District: 1. Application of Standards: a. Redevelopment District is Exempted from Historic Overlay Standards: Construction of new structures and renovation or expansion of existing non- contributing structures not listed on the most recent "Above-Ground Survey of Historic Resources" within a designated redevelopment district shall be exempt from the standards of the historic overlay. b. Historic Structures: Demolition, renovation, or expansion of structures that are listed as "contributing" on the most recent "Above-Ground Survey of Historic Resources" shall be subject to approval by the HRB in accordance with Section 9.10. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 34 of 73 2. Exceptions to Section 3.2 Table of Permitted Uses: Inns and Hotels are permitted by-right in this redevelopment district, and are not subject to the conditions in 3.6.2.C.3. 3. Street Hierarchy: The hierarchy of streets in this district is as follows, from highest to lowest: Bladen Street, North Street, Duke Street, Prince Street, Adventure Street. Bladen Street is the most important street in the redevelopment district. 4. Master Plan: See Appendix B.2.3 for the original Bladen Street Master Plan. G. Specific to the Boundary Street Redevelopment District: 1. Existing Planned Unit Developments: For existing City-approved planned unit developments (PUD) in the district, the PUD shall apply through February 6, 2032, a period of up to 25 years from the date of adoption of the Boundary Street Redevelopment District. Once 25 years pass, said PUDs are no longer applicable and shall then fall under the regulations of the Boundary Street Redevelopment District and underlying zoning. 2. Existing Buildings: With respect to existing buildings within the Redevelopment District, their use may be maintained despite changes made to allowable uses. In the event the building undergoes either structural or cosmetic modifications, if the cost of improvements exceeds 50% of the Fair Market Value of the building, it will be subject to the standards set forth by this code. This does not include repairs to a building, provided that the configuration is not modified or altered during the repairs. The Administrator (syn. City Architect) will have final jurisdiction over this matter. Signs not conforming to the requirements of this section shall be altered, removed, or otherwise brought into compliance with the requirements of this section at the time that the required building improvements are made. 3. Specific Standards: Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 35 of 73 a. Exceptions to Section 3.2 Table of Permitted Uses: Single-family detached uses are permitted regardless of the zoning district, except along Boundary Street and Robert Smalls Parkway. They are subject to all development standards laid out in this Code. b. Streets: All applications for development in the Boundary Street Redevelopment District shall include the design of street elements adjacent to the applicant's property. These designs shall be according to the street type adjacent to the property, as identified in the Street Regulating Plan (Appendix C). The street type and the appropriate thoroughfare sections inform the applicant regarding how parking, sidewalk, tree plantings and other elements are to be sized and arranged. Contact with the City architect will provide clarification about the required design for each street. All streets and alleys shall connect to other streets. Cul-de-sacs and T-turnarounds are not permitted. i. Street Hierarchy: The hierarchy of streets/street types in this district is as follows, from highest to lowest: Boundary Street (US 21), Ribaut Road, Robert Smalls Parkway (SC 170), Parallel Street, Edge Drive, Main Street, Park Street, Neighborhood Street, House Street. This hierarchy serves as an informal phasing and prioritization plan. ii. Construction of New Streets: See Section 7.2.1 D. c. Alleys: Alleys are required in the Boundary Street Redevelopment District to minimize curb cuts and to provide access to parking and service areas behind buildings. Alley requirements may be waived by the City architect for access to detached single-family residential lots greater than 45 feet in width in situations in which proper street front orientation, pedestrian circulation, and parking can still be accomplished. Alley locations and dimensions are not fixed but shall be designed to accommodate the alley's purpose. Alleys may be incorporated into parking lots as drive aisles and fire lanes. Recommended sections for alleys are included in Appendix C. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 36 of 73 4. Master Plan: See Appendix B.3.2 for the Boundary Street Illustrative Master Plan. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 37 of 73 2.7.4 AIR INSTALLATION COMPATIBILITY USE ZONE (AICUZ) OVERLAY DISTRICT STANDARDS A. Purpose: The Air Installation Compatibility Use Zone (AICUZ) District shall overlay other zoning districts. The AICUZ District includes all lands within an established footprint affected by airport operations at the Marine Corps Air Station Beaufort (MCAS Beaufort). The footprint includes all lands underlying the noise zones of 65 DNL (day-night average sound level) and greater, and accident potential zones shown on the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, on file at the City of Beaufort Department of Planning and Development Services. Properties within Noise Zone 1 are exempt from the requirements of this section. In order to increase public awareness, and to ensure the general safety and welfare of persons affected by adverse impacts common to military aircraft operations, Section E. of this ordinance requires that property owners within the AICUZ District be properly notified of their location. In addition, Section 2.7.4 K. sets forth limitations and restrictions that shall apply to certain land uses that have been determined to be incompatible according to federal standards. B. Obstruction Height Zones: There are hereby created and established certain zones that include all of the land lying beneath the primary, clear zone, approach clearance, inner horizontal, conical, outer horizontal, and transitional surfaces as they apply to MCAS Beaufort. An area located in more than one of the described zones is considered to be only in the zone with the more restrictive height limitation. The various zones are hereby established and defined as follows: Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 38 of 73 ZONE DEFINITION MAXIMUM HEIGHT Primary Zone An area located on the ground or water, longitudinally centered on each runway with the same length as the runway — the width of the primary zone is 1,500 feet No object or structure will be permitted within a primary zone that is not part of the landing and take-off facilities and is of a greater elevation above mean sea level (AMSL) height than the nearest point of the runway centerline. Clear Zone The fan-shaped area adjacent to the landing threshold, beginning at each end of each primary zone and expanding to 2,284 feet wide, 3,000 feet from the threshold at an angle of 7 degrees, 58 minutes, 11 seconds, commencing 200 feet from the threshold No object or structure will be permitted within the first 200 feet of a clear zone that is not part of the landing and take-off facilities and is of a greater elevation AMSL height than the nearest point of the runway centerline. No object or structure will be permitted within the remaining 800 feet of a clear zone that is not part of the landing and take-off facilities and is of a greater elevation AMSL height than those heights prescribed as the maximum heights for the approach clearance zone and transitional zone. Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 39 of 73 Approach Clearance Zone An area longitudinally centered about each runway centerline extended, beginning 200 feet beyond each end of the primary zone and extending outward for 50,000 feet — the width of the approach clearance zone is the same as the primary zone, uniformly flaring to 16,000 feet at 50,000 feet distance No object or structure will be permitted within the approach clearance zone beginning 200 feet from the runway end, that has a height greater than the runway end elevation at its centerline, the height above the runway end increasing with horizontal distance outward one foot vertically for every 50 feet horizontally until reaching a height 500 feet above the established airport elevation, then remaining at this AMSL elevation until a distance of 50,000 feet from the beginning point is reached. Inner Horizontal Zone An area around each military airfield constructed by scribing an arc of 7,500 feet about the end of each runway at its centerline and interconnecting the arcs by tangents No object or structure will be permitted in the inner horizontal zone that has a height greater than 150 feet above the established airport elevation. Conical Zone An area extending outward from the periphery of the inner horizontal zone outward and upward at a slope of 20:1 for 7,000 feet No object or structure will be permitted in the conical zone that has a height greater than 150 feet above the established airport elevation at its inner boundary with permitted height increasing one foot vertically for every 20 feet of horizontal distance measured outward from the inner boundary to a height 500 feet above the established airport elevation at the outer boundary. Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 40 of 73 Outer Horizontal Zone An area extending outward from the outer periphery of the airfield's conical zone for a distance of 30,000 feet No object or structure will be permitted in the outer horizontal zone that has a height greater than 500 feet above the established airport elevation. Transitional Zones Areas extending outward from the sides of the primary zone, the first 200 feet of the clear zone, and the approach clearance zone, connecting them to the inner horizontal zone, the conical zone, and the outer horizontal zone No object or structure will be permitted within the transitional zone that is greater in height than the primary zone, the clear zone, and the approach clearance zone at their adjoining boundary lines, increasing at a rate of one foot vertically for every seven feet horizontally, measured perpendicular to the runway centerline or centerline extended, until the transitional zone height matches the height of the inner horizontal zone, the conical zone, or the outer horizontal zone. (1) Outside of the zones established in Section 2.7.4 B., no object or structure will be permitted within the City whose height would: (a) Exceed 500 feet above ground level at its site. Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 41 of 73 (b) cause an existing MDA, MOCA, MVA, or a decision height to be raised. (Note: minimum descent altitude (MDA) is the lowest AMSL altitude to which descent is authorized on final approach or during circling-to land maneuvering in execution of a standard instrument approach procedure (SIAP) where electronic glide slope is not provided. Minimum obstruction clearance altitude (MOCA) is the lowest published altitude between radio fixes on federal VOR airways, off-airway routes, or route segments that meets obstruction clearance requirements for the entire route segment and assures acceptable navigational signal coverage only within 22 miles of a VOR. Minimum vectoring altitude (MVA) is the lowest AMSL altitude at which aircraft operating on Instrument Flight Rules (IFR) will be vectored by a radar controller, except when otherwise authorized for radar approaches, departures, or missed approaches). (c) impose either the establishment of restrictive minimum climb gradients or nonstandard take-off weather minimums for any runway at MCAS Beaufort. C. Accident Potential Zones (APZ): APZs are divided into three types along primary flight paths: • The "clear zone" (CZ) is an area at either end of a runway that possesses a high potential for accidents. • APZ-1 is the area normally beyond the CZ, which possesses a significant potential for accidents. • APZ-2 is an area normally beyond APZ-1, which has a measurable potential for accidents. APZs are shown on the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, on file at the City of Beaufort Department of Planning and Development Services. D. Noise Zones: Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 42 of 73 1. Definition: The noise exposure from aircraft operations is measured using the day-night average sound level noise metric (DNL). The DNL averages aircraft sound levels over a 24-hour period with an adjustment for increased sensitivity to nighttime noise. The DNL visually is depicted as a noise contour that connects points of equal value. The area between two noise contours is known as a "noise zone". Noise zones are hereby established as follows: AIRPORT NOISE ZONE DNL VALUES 1 Less than 65 DNL 2a 65 to 70 DNL 2b 70 to 75 DNL 3 Greater than 75 DNL Noise zones are shown on the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, on file at the City of Beaufort Department of Planning and Development Services. Noise Zone 1 covers that portion of the City that lies outside of the Air Installation Compatible Use Zone. As indicated in Section 2.7.4 A., properties within Noise Zone 1 are exempt from the requirements of this section. Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 43 of 73 2. Residential Construction Restrictions: Aside from the residential construction restrictions imposed by this overlay, more stringent requirements of the base zoning district may also apply. For the purposes of this section, "gross density" means the total number of dwelling units (which include any building or portion thereof used as a place of residence, such as single-family dwellings, multi-family dwellings, commercial apartments, live/work units, garage apartments, accessory dwelling units, etc.) on a site divided by the entire site area. a. Residential development is not permitted in a Clear Zone. b. Single-family residential development within Accident Potential Zone (APZ 1 and APZ 2) and/or within Noise Zone 3 (DNL 75 and above) may not exceed a gross density of one (1) dwelling unit per three (3) acres. c. Residential development within Noise Zone 2b (DNL 70 to 75) may not exceed a gross density of one (1) dwelling unit per acre. d. Residential development within Noise Zone 2a (DNL 65 to 70) may not exceed a gross density of two (2) dwelling units per acre. 2.7.4 E. Notification: 1. At all real estate closings involving a property in an APZ or noise zone as depicted on the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, on file at the City of Beaufort Department of Planning and Development Services, the buyer, seller, and witnesses shall sign the following AICUZ disclosure form which shall be filed with the deed and/or plat at the Beaufort County Register of Deeds Office. Property owners may contact the City of Beaufort Department of Planning and Development Services to obtain information concerning a property's designation on the AICUZ Maps. Air Installation Compatible Use Zone Disclosure Form Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 44 of 73 The property at _______ (address/location) is located in proximity to the Marine Corps Air Station Beaufort. The City of Beaufort has determined that persons on the premises will be exposed to accident potentials and/or significant noise levels as a result of the airport operations. The City has established certain noise zones and accident potential zones (APZs). Pursuant to the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, the above property is located in: Noise Zone (2a, 2b, or 3) _______ and Accident Potential Zone (CZ, APZ-1, or APZ-2) _______. The City has placed certain restrictions on the development and use of property within these areas. Before purchasing the above property, you should consult the Administrator to determine the restrictions that have been placed on the subject property. CERTIFICATION As the owner of the subject property, I hereby certify that I have informed _______, as a prospective purchaser, that the subject property is located in an Air Installation Compatibility Use Zone District. Dated this _______ day of _______, _______. Witness_______Owner_______ As a prospective purchaser of the subject property, I hereby certify that I have been informed that the subject property is in an Air Installation Compatible Use Zone District, and I have consulted the Administrator to determine the restrictions which have been placed on the subject property. Dated this _______ day of _______, _______. Witness_______Purchaser_______ Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 45 of 73 2. All prospective renters signing a commercial or residential lease shall be notified by the property owner through a written provision contained in the lease agreement if the leased property is located within the AICUZ District. 3. All subdivision plats, planned unit development plats, rowhome plats and /or condominium documents in the AICUZ District shall contain the following Acknowledgement: Air Installation Compatible Use Zone Disclosure Statement This property lies in an Air Installation Compatible Use Zone District, which applies to property in proximity to the Marine Corps Air Station Beaufort. The City of Beaufort has determined that persons on the premises will be exposed to accident potentials and/or significant noise levels as a result of the military operations. Future purchasers and lessors of this property or portions thereof will be required to sign a disclosure form per the City of Beaufort Planning Department and file the form with the deed and/or plat at the Beaufort County Register of Deeds Office (RMC Office). All or a portion of this property lies within: Pursuant to the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B, all or a portion of this property lies within: Noise Zone (2a, 2b, or 3): _______, which has an associated DNL (Day-Night Average Sound Level) of: _______ Accident Potential Zone (CZ, APZ-1, or APZ-2): _______ In the case of new construction, a signed AICUZ Acknowledgement shall accompany the building permit application. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 46 of 73 AICUZ OVERLAY TABLE OF PERMITTED AND PROHIBITED USES1, 2 AIRPORT HAZARD ZONE AIRPORT NOISE CLEAR APZ-1 APZ-2 ZONE 3 Recreation, Education, Public Assembly Community-Oriented Cultural Facilities N N N N Institutional Care Facilities N N N N Detention Facilities N N N N Hospitals and Health Clinics N N N N Assembly and Worship/Religious Institutions N N N N School, Public or Private N N N N Commercial Day Care Centers N N N N Commercial Lodging/Overnight Guest Accommodations N N N N Restaurant, Cafe, Coffee Shop N N N N Commercial Amusement (Indoor & Outdoor)/Indoor Recreation and Entertainment/Outdoor Entertainment N N N N Health/Fitness Facility N N N Y Commercial Retail Center N N N N Parks with Active Recreation N N N N Mobile/Manufactured Home Parks N N N N Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 47 of 73 Storage of Explosive, Flammable or Toxic Materials in Above-Ground Tanks N N N N Petroleum Refining and Related Industries N N N Y Chemical Manufacturing, Manufacturing of Plastic and/or Rubber N N N N Group Home/Community Residence/Temporary Shelter N N N Y Residential 2-3 Unit Buildings or Multi-Family (syn. Apartment House) N N N N Single Family Attached N N N N Single-Family/Unit: 1 unit or less per 3 acres 3 N Y Y Y Single-Family/Unit: 1 unit or less per 1 acre 3 N N N N Single-Family/Unit: 2 unit or less per 1 acre 3 N N N N N = Not permitted use Y = Permitted if underlying district allows use (see Section 3.2 Permitted Land Uses) 1 A definition of each listed use type is in Article 13 (Definitions). 2 Similar uses, and any other retail business or service establishment permitted or conditionally permitted as determined by the Administrator, shall be of the same general character as the listed uses. 3 See Section 2.7.4 D.2. for complete information on Residential Construction Restrictions based on specific Noise Zones. F. Notice to Military Installations: Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 48 of 73 1. S.C. Code 1976 § 6-29-1610, as amended, sets forth notice requirements pertaining to federal military installations. The provisions of this subsection shall apply to the following types of land use and zoning decisions when such decisions involve land located within an Accident Potential Zone or Noise Zone, pursuant to the 2013 AICUZ Accident Potential Zones and/or Noise Zones Map associated with the F-35B: a. Adoption of or amendment to the City of Beaufort Comprehensive Plan; b. An appeal to the City of Beaufort Zoning Board of Appeals (ZBOA); c. A request to the ZBOA for a variance from the provisions of City of Beaufort Unified Development Ordinance; or d. A request to the ZBOA for approval of a Special Exception Use. (Ord. No. O-19-17 , (Att.), 7-25-2017) Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 49 of 73 2.7.5 BEAUFORT COUNTY AIRPORT OVERLAY DISTRICT STANDARDS A. Description: The Airport has one runway designated as Runway 7/25. The runway accommodates aircraft over 12,500 pounds and is therefore classified as "other than utility runway." Since aircraft can land in either direction, non- precision-instrument approaches with visibility minimums greater than three- fourths of a statute mile have been approved and published by the FAA for both ends of Runway 7/25 at the Airport. These classifications are current as of October 2006. The following prescribes the airport height zones and limitations for Beaufort County Airport as dictated by Title 14 Code of Federal Regulations Part 77. A property located in more than one of the described zones is considered to be in only one zone with the more restrictive height limitation. B. Airport Overlay Zones: 1. Primary Zone: This is an area longitudinally centered on a runway, extending 200 feet beyond each end of that runway with the width so specified for each runway for the most precise approach existing or planned for either end of the runway. The width of the primary zone is as follows: 500 feet for non-precision instrument runways having visibility minimum greater than three- fourths of a statute mile. 2. Horizontal Zone: This is the area around a civil airport with an outer boundary perimeter of which is constructed by swinging arcs of specified radii from the center of each end of the primary zone of each airport's runway and connecting the adjacent arcs by line tangent to the arcs. The radius of the arc specified for each end of a runway will have the same arithmetical value. That value will be the highest composite value determined for either end of the runway. The radius of each arc is: a. Runway 7 End: Ten thousand feet for non-precision instrument runways having visibility minimum greater than three-fourths of a statute mile. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 50 of 73 b. Runway 25 End: Ten thousand feet for non-precision-instrument runways having visibility minimum greater than three-fourths of a statute mile. 3. Conical Zone: This is the area extending outward from the periphery of the horizontal zone for a distance of 4,000 feet. 4. Approach Zone: This is an area longitudinally centered on the extended runway centerline and extending outward from each end of the primary surface. An approach zone is designed for each runway end based upon the type of approach available or planned for that runway end. a. The inner edge of the approach zone is the same width as the primary zone (i.e., 500 feet) and it expands uniformly to a width of: i. Runway 7 End: Three thousand five hundred feet for non-precision instrument runways having visibility minimum greater than three-fourths of a statute mile. ii. Runway 25 End: Three thousand five hundred feet for non-precision instrument runways having visibility minimum greater than three-fourths of a statute mile. b. The outer width of an approach zone to an end of a runway will be that width prescribed in this Subsection for the most precise approach existing or planned for that runway end. c. The approach surface extends for a horizontal distance of: i. Runway 7 End: Ten thousand feet for all non-precision-instrument runways other than utility. ii. Runway 25 End: Ten thousand feet for all non-precision-instrument runways other than utility. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 51 of 73 5. Transitional Zone: This is the area extending outward from the sides of the primary zones and approach zones connecting them to the horizontal zone. Height limits within the transitional zone are the same as the primary zone or approach zone at the boundary line where it adjoins and increases at a rate of one foot vertically for every seven feet horizontally, with the horizontal distance measured at right angles to the runway centerline and extended centerline, until the height matches the height of the horizontal zone or conical zone or for a horizontal distance of 2,000 feet from the side of the part of a precision approach zone that extends beyond the conical zone. C. Use Limitations: The following special requirements shall apply to uses within the Airport Overlay that are allowed in the base zone: 1. Lights or illumination used in conjunction with streets, parking, signs or use of land and structures shall be arranged and operated in such a manner that is not misleading or dangerous to aircraft operating from the airport or in the vicinity thereof as determined by the airport operator. 2. No operations of any type shall produce smoke, glare or other visual hazards within three miles of a usable runway. 3. No operations of any type shall produce electronic interference with navigation signals or radio communication between the airport and the aircraft. 4. No use of land shall be permitted which encourages large concentrations of birds, waterfowl or other wildlife within the vicinity of the airport. D. Official Map: The airport height zones defined in Section A. are shown on the map entitled "Beaufort County Airport Overlay District" which is incorporated herein by reference. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 52 of 73 E. Notification: At all real estate closings involving a property in the approach zone or transitional zone, the buyer, seller and witnesses shall sign the following form, which shall be filed with the deed and/or plat at the Beaufort County Register of Deeds Office. Airport Overlay Disclosure Form (For Properties within the Approach Zone or Transitional Zone of the Beaufort County Airport Overlay District) The property at _______ (address/location) is located within the _______ Zone of the Airport Overlay District for the Beaufort County Airport (73J). Beaufort County has determined that persons on the premises may be exposed to noise and accident potentials from aircraft over flight as a result of airport operations. The County has placed certain height restrictions on this property for both man- made and natural obstructions based on its location within this airport height zone. Before purchasing the above property, you should consult with the Beaufort County Zoning and Development Administrator to determine the restrictions that have been placed on the subject property. CERTIFICATION As the owner of the subject property, I hereby certify that I have informed _______, as a prospective purchaser, that the subject property is located in the _______ Zone of the Beaufort County Airport Overlay District. Dated this _______ day of _______/_______/_______, _______. Witness_______ Owner_______ Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 53 of 73 As a prospective purchaser of the subject property, I hereby certify that I have been informed that the subject property is in the _______ Zone of the Beaufort County Airport Overlay District, and I have consulted with the Beaufort County Zoning and Development Administrator to determine the restrictions which have been placed on the subject property. Dated this _______ day of _______/ _______/ _______, _______. Witness_______ Purchaser_______ Division 3.4: Overlay Zones Beaufort County Airport Overlay (BC-AO) District 3-76 Beaufort County Community Development Code 2. All subdivision plats, planned unit development plats, townhouse plats and/or condominium documents shall contain the following disclosure statement: Airport Overlay Disclosure Statement (For Properties within the Beaufort County Airport Overlay District) This property lies within an Airport Overlay District for the Beaufort County Airport. There are structure height restrictions imposed on this property based on its location within an airport height zone. Purchasers should contact the Beaufort County Community Development Department for information regarding these restrictions. All or a portion of this property lies within: Airport Height Zone: _______ F. Non-Conforming Uses and Structures: See Article 11 for all non- conformities. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 54 of 73 G. Variances: The Zoning Board of Appeals (ZBOA - See Section 10.3) shall not act upon a request for a variance from this section affecting lands within the AO Zone until they have received an advisory opinion from the Beaufort County Aviation Advisory Board. If an advisory opinion is not received within 30 days of notification, the ZBOA may proceed to act on the request without the opinion. 2.8: ALTERNATIVE DEVELOPMENT PATTERNS Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 55 of 73 2.8.1 SMALL-SCALE PLANNED INFILL DEVELOPMENT A. Purpose: The alternative development options of this section allow for variety in development standards while maintaining the overall character of a neighborhood. These options have several public benefits: • They allow for development that is more sensitive to the environment, especially in areas with water features, natural drainage-ways, and significant trees; • They allow for the preservation of open and natural areas; • They promote better site layout and opportunities for private recreational areas; • They promote opportunities for affordable housing by allowing for a mixture of lot and building sizes; and • They promote energy-efficient development. B. Definition: A small-scale planned infill development is a residential subdivision in which the lots are allowed to be smaller (in area and width), have reduced setbacks, and/or are oriented in a different manner than otherwise required for the underlying base zoning district, but in which the overall density cannot exceed the maximum density limit for the underlying zoning district. C. Applicability: Subdivisions that comprise a minimum size of 1/2 acre (in T3 or T4 districts only) or an entire block face may utilize these standards. D. Conflict with Other Regulations: If there is a conflict between the small- scale planned infill standards of this section and any other requirement of this Code, the standards of this section take precedence. Otherwise, a small-scale planned infill is subject to all other applicable requirements of this Code. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 56 of 73 E. Approval Procedures: Small-scale planned infill developments are subject to the subdivision review procedures set forth in Section 9.9 with the following exceptions: 1. In the Historic District, these developments are also subject to review by the Historic Review Board (Section 9.10). 2. In T3-S these developments are permitted by Special Exception and are subject to review by the Zoning Board of Appeals (Section 10.3). F. Lot Size: There is no set minimum lot size (area or width) requirement within a small-scale planned infill development. Individual lot sizes shall be adequate to meet all required density and development standards. Minimum lot sizes may be established by the Planning Commission during the subdivision process. G. Setbacks and Building Separation: The minimum setback and frontage standards of the base zoning district apply along the perimeter of a small-scale planned infill development. All detached structures within a small-scale planned infill development shall be separated by a minimum distance of 10 feet. This distance may be reduced subject to the building code. H. Open Space Requirement: A portion of the gross area of the development shall be reserved for some type of usable, common open space. See Section 7.4.2 and 3 for required amounts and appropriate types of open space. See Section 7.4.5 for ownership and maintenance requirements. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 57 of 73 2.8.2 COTTAGE COURTS (A.K.A. BUNGALOW COURTS, POCKET NEIGHBORHOODS, COURTYARD HOMES) A. Purpose: The alternative development options of this section allow for development of smaller dwelling units, organized around a common outdoor space, that are appropriate to the character of the surrounding neighborhood. They provide a space-efficient and economical alternative to traditional single dwelling unit development. The ownership model may be either fee-simple or condominium-style, and can achieve the same benefits as those listed in Section 2.8.1 A. B. Definition: A Cottage Court development is a residential development in which small buildings are oriented around a central green or open space that is accessible by all residents. C. Density: Additional density is permitted, as follows, in exchange for the buildings having a limited footprint, size, and height: 1. In T3-S the overall density is permitted to be up to 1.25 times the maximum density limit. 2. In T3-N the overall density is permitted to be up to 2 times the maximum density limit. D. Applicability: Cottage Courts are permitted in T3 and T4 districts only. They are not permitted in the Historic District. E. Lot Size: Prior to development, lots or combinations of lots shall meet the following dimensional standards: 1. 160 feet wide by 100 feet deep where formalized parking on-street exists on adjacent streets and no on-site parking is required. 2. 180 feet wide by 100 feet deep if on-site parking is required. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 58 of 73 3. Exception: In T3-S, Cottage Courts are limited to lots greater than 1 acre. F. Conflict with Other Regulations: If there is a conflict between the cottage courts standards of this section and any other requirement of this Code, the standards of this section control. Otherwise, cottage courts are subject to all other applicable requirements of this Code. G. Approval Procedure: Cottage courts are subject to the subdivision review procedures set forth in Section 9.9. H. Number of Buildings: Cottage courts shall contain a minimum of 4 residential buildings. For courts that have 8 or more buildings, a community structure shall be provided. Examples of these include garden sheds, pavilions, community houses, etc. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 59 of 73 I. Building Size and Details: 1. Buildings may have a maximum 800 square foot footprint (not including porches), and may be no more than 1.5 stories tall. 2. Front porches shall be provided facing the common space, and they shall be a minimum of 8 feet deep. 3. Where a building is located on both a public street and a public space, it shall address the street with either a porch or stoop, and shall provide entries onto both spaces. 4. The public spaces of the home shall be located facing the common space. These include living, dining, and kitchen areas. First-floor bedrooms should not be located fronting the civic space. An exception to this shall be made on corner lots, where public spaces may face the street. J. Setbacks and Building Separation: The minimum setback and frontage standards of the base zoning district apply along the perimeter of a cottage court development. Buildings may be attached or detached. All detached structures within a cottage court development shall be separated by a minimum distance of 10 feet. This distance may be reduced, subject to the building code. K. Parking Requirements and Configuration: One space per unit is required. Adjacent on-street parking spaces may count towards this requirement. Parking shall be screened from the public right-of-way by buildings. A common parking area, accessed via an alley, is recommended. If this is not possible, access easement(s) shall be provided as part of the final plat. Parking shall be screened from neighboring properties per the requirements of Section 5.7.8 A. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 60 of 73 L. Open Space Requirement: A minimum of 400 square feet of common open space is required per unit. The open space shall be connected to the public right-of-way either by opening up to the street, or via a paved path no less than 8 feet wide. Ownership and maintenance requirements shall be in accordance with Section 7.4.5. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 61 of 73 2.8.3 TRADITIONAL NEIGHBORHOOD DEVELOPMENT FLOATING OVERLAY DISTRICT A. Purpose and Intent: The Traditional Neighborhood Development (TND) overlay District is established to: • Support the development of fully integrated, mixed-use, pedestrian- oriented neighborhoods with a variety of housing choices. • Prevent the development of large, single-use, homogenous subdivisions. • Minimize traffic congestion, suburban sprawl, infrastructure costs and environmental degradation. • Create a streamlined way to transition the City's zoning to the Transect- zones. B. Process and Applicability: The application of the TND overlay district shall depend upon the size of the site in accordance with the provisions below. The TND overlay district shall not be applied to any site with a T1 (Natural Preserve District) base district designation. 1. General Process: a. Master Plan: Applicants shall first develop and present a master plan, complying with the Sketch Plan requirements in 9.3.1.B, for the entire parcel which shall include land allocations by Transect zone, proposed subdivisions of property, required open space, street regulating plan, neighborhood structure(s) and other information required to indicate compliance with this section. Upon approval by the MPC - and subsequent rezoning approval as applicable - the master plan is vested. b. Preliminary Plat: Upon approval of the Master Plan, the applicant shall proceed towards approval of a Preliminary Plat (Section 9.9.3). Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 62 of 73 2. Applicability: TND APPLICABILITY SUMMARY TABLE SITE AREA PROCESS TYPE 15 acres to 40 acres Optional with Conditional TND designation (See a., below) 40 acres to 100 acres Optional with By-Right TND designation (See b., below) 100 acres or larger Mandatory with By-Right TND designation (See c., below) a. 15—40 acres: Sites having at least 15 acres but less than 40 acres may be developed under a TND overlay district. Development sites with a base zoning of T3 shall be subject to the rezoning process consistent with Section 9.16. Development sites with a base zoning of T4 or T5 shall follow the procedures for Major Subdivisions found in Sections 9.9.3 and 9.9.4. b. 40—100 acres: The TND overlay District designation shall automatically apply by-right to all development sites of at least 40 acres but less than 100 acres. Applicants shall have the option of developing such sites using the standards of the TND overlay district or the standards of the underlying base zoning district. The approval of TND master plans on such properties shall follow the procedures for major subdivisions found in Sections 9.9.3 and 9.9.4. Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 63 of 73 c. 100+ acres: The TND overlay District designation shall automatically apply by-right to all development sites of at least 100 acres. Development sites of this size are required to follow the standards of the TND overlay district. The approval of TND master plans on such properties shall follow the procedures for major subdivisions found in Sections 9.9.3 and 9.9.4. d. Exceptions: Land designated as LI and IC districts are not subject to these provisions and may be developed as more conventional, single-purpose developments. C. Land Allocation by Transect Zones: When composing the TND master plan, the Transect-based districts in Section 2.3.2 shall be used as sub-districts within the ranges noted in the following chart. The allocation of land by Transect zone shall be made a part of all applications and approvals for TND master plans. All development shall conform to the standards of the designated form-based sub-district in which it is located, unless otherwise noted in this section. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 64 of 73 15—40 ACRES GREATER THAN 40 ACRES BASE ZONE TRANSECT ZONE MINIMUM AREA* MAXIMUM AREA* MINIMUM AREA* MAXIMUM AREA* T3 T3 districts 30% 85% 30% 75% T4 districts 10% 50% 10% 50% T5 districts None 10% None 30% T4 T3 districts None 50% None 60% T4 districts 10% 50% 20% 90% T5 districts None 30% None 40% T5 T3 districts None 30% None 40% T4 districts 10% 50% 10% 50% T5 districts 20% 80% 30% 80% * Listed as % of gross land area. Note: T4-NA sub-district may be incorporated as no more than 1/3 of the permitted T4 allocation. D. Land Uses: 1. The TND master plan shall include a regulating plan designating each Transect zone (T-zone) by parcel. 2. Land uses shall be limited to those permitted in the designated T-zone. Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2, Left Formatted: Heading 2 Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 65 of 73 3. Similar T-zones shall generally front across streets. Dissimilar categories shall abut at rear lot lines or transition mid-block. E. Civic/Open Space: 1. Development shall be required to reserve usable, common open space in accordance with the standards for the underlying base district(s), as specified in Sections 7.4.2 and 3. 2. No portion of the TND shall be further than ¼ mile from a Community Green Space, as defined in Section 7.4.3. Existing common open spaces outside of the TND boundaries may be used to satisfy this requirement. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 66 of 73 3. On parcels 40 acres and larger, a minimum of 2% of the gross land area shall be reserved for the construction of community structures, (schools, community buildings, religious institutions, etc.) and their support facilities (parking areas, etc.). These sites shall be counted towards the open space requirement. Such sites shall be easily accessible within the neighborhood — and to the greater community where appropriate — and shall help to visually anchor important vistas. See Section 4.5.13 for building design standards for civic buildings. If after 5 years, the community facilities are not constructed, the land may be converted to common open space. F. Neighborhood Structure: 1. TNDs shall be organized by individual pedestrian sheds (or walking areas) with a ¼-mile radius (1,320 linear feet). 2. Neighborhood centers/main streets shall be located at or near the center of all pedestrian sheds, and shall include: a. The area of the TND with the greatest intensity of development, b. One or more civic buildings and/or uses, and Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 67 of 73 c. One or more Community Green Spaces. 3. Each pedestrian shed is encouraged to include a variety of uses, building types, and housing types, so that the majority of lots within the TND are within walking distance (no more than ½ mile) of a neighborhood center, and at least 2 types of housing are provided (e.g., single-family detached, rowhomes, duplexes, apartments) per pedestrian shed. 4. Street networks shall be interconnected using a grid or modified grid. Exceptions and special designs can be considered due to geography and special site conditions. 5. Block Size: Blocks shall be compact so that they are comfortably walkable and appropriate for their context. a. In T3-S zones, block sizes are flexible, but the perimeter shall not exceed 2,640 linear feet (½ mile). An average block perimeter less than 2,000 feet is preferred. b. In T3-N zones, block sizes are flexible, but the perimeter shall not exceed 1,700 linear feet (½ mile). An average block perimeter less than 1,500 feet is preferred. c. In T4, and T5 zones, blocks shall be no more than 400 feet on any side. An average block length of 250-300 feet is preferred. The block perimeter shall not exceed 1,320 linear feet (¼-mile). d. Exceptions may be made for natural elements such as wetlands, trees, topography, to be incorporated into the site design. 6. Within 200 feet of all parcels outside the TND, lot widths, depths, and building types shall provide a graduated transition to adjacent development, particularly any such areas that are of a lower intensity/density. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 68 of 73 G. Relief: Modifications to these standards may be reviewed and permitted by the MPC if the plan is found to still be in compliance with the intent of this Code. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 69 of 73 2.8.4 PLANNED UNIT DEVELOPMENT DISTRICT (PUD) A. Purpose and Intent: The PUD is intended to encourage innovative land planning and site design concepts that cannot be achieved by other mechanisms provided by this Code. PUDs should achieve a high level of environmental sensitivity, aesthetics, high quality development and other community goals by: 1. Allowing greater freedom in selecting the means to provide access, open space and design amenities. 2. Promoting quality urban design and environmentally sensitive development by allowing development to take advantage of special and unique site characteristics, locations, building types and land uses. B. Process and Applicability: 1. General Process: PUDs are considered a two step process. First, there is a Rezoning which follow the general procedures of Section 9.16. Second, a Final Plat approval, per Section 9.9.4 shall occur. A complete master plan and written report shall be developed and submitted for approval as part of the rezoning process in order to determine the desired standards and design of the project. Those documents shall be submitted in accordance with the following standards: a. Master Plan: Applicants shall first develop and present a master plan, complying with the Sketch Plan requirements in 9.3.1.B, for the entire parcel which includes, but is not limited to: i. Size: Size, in acres, shall be listed on the master plan. For redevelopment sites, as defined in Section 8.3.2 A., PUDs shall have a minimum of 4 acres. For all other developments PUDs shall have a minimum of 10 acres. If the project is intended to be developed in phases, the master plan shall include all phases. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 70 of 73 ii. Districts: Land allocations by zoning district, including specific modifications to the Code requirements of those districts clearly highlighted. iii. Street Layout and Regulating Plan: the design and location of the streets shall be provided. Streets shall conform with the street sections in Appendix C of this Code. Additional bicycle and pedestrian circulation shall also be indicated. iv. Lot Layout: Proposed subdivisions of property, required open space, street regulating plan, neighborhood structure(s). The PUD shall have provisions to allow for a systematic methodology to provide a variety of lot sizes. v. Open Space: Open space requirements are 1.5 times the standards set in Section 7.4.2 with the exception that a minimum of 10% open space is required for all PUDs, regardless of size or zoning district. These should be clearly indicated on the master plan. vi. Community Space: the requirements of 2.8.3.C.3 shall be met. vii. Stormwater Requirements: Stormwater shall be considered on a PUD- wide basis and the general locations shall be indicated. Floodplain information shall also be included on the master plan. viii. Resources: The general location of all historic, cultural, and environmentally sensitive resources shall be depicted on the master plan. b. Written Report: A written report shall be submitted to explain the type, nature, intent and characteristics of the proposed development, and shall specifically include: i. Site Description: A general description of the proposal, including a detailed description of the site, location, context, and any cultural, environmental and/or historic resources. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 71 of 73 ii. Vision Statement: The goals, tenets, any special initiatives which the development intends to achieve shall be clearly identified for review and discussion. iii. Incompatibilities: A detailed description of the provisions of the Code which prevent the development, as desired shall be provided. This shall include analysis showing how the general Land Development standards in Article 7, and the TND Floating Overlay District standards in Section 2.8.3 limit the intended development. iv. Modification to Code: A detailed description of exceptions or variations from the requirements of this Code, per the incompatibilities listed above. All items not explicitly listed as modifications will be subject to the requirements of this Code. v. Land Allocation: Tables showing the total number of acres in the proposed development and the percentage designated for each proposed type of land use, including open spaces, recreation areas, public facilities, wetlands and wetland impacts. This should be coordinated with the Districts as shown in the master plan. If the development is intended to be phased, the phasing plan shall be indicated on the tables. vi. Program: A complete development program, including number of residential units and proposed densities, building types, minimum and maximum lot sizes, and square feet and identification of other nonresidential uses. vii. Building Design Standards: Guidelines to achieve aesthetics and high quality development shall be included. These may be further elucidated in the covenants after all City approvals have been secured. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 72 of 73 viii. Compatibility Statement: A statement of how the proposed development is consistent adopted plans and documents, including, but not limited to, the Civic Master Plan, the most recent Comprehensive Plan, applicable stormwater regulations, other model ordinances and/or applicable development standards. ix. Other: Additional relevant information as requested by the Administrator. c. Performance Guarantee: Before approval of a PUD, the City Council may require a contract with safeguards satisfactory to the City guaranteeing completion of the development plan in a period to be specified by the City, but which period shall not exceed 5 years unless extended by the City for due cause show. Such guarantee may include the submission of a performance bond in an amount set by the City. d. Final Plat: Upon approval of the Rezoning (inclusive of the master plan), the applicant shall proceed towards approval of a Final Plat (Section 9.9.4). C. Expiration of Approval: The City shall have the right to review a concept plan approved as part of a PUD when no building permits have been issued in the past 5 years, and may choose not to issue further permits within the PUD until a revised concept plan has been approved. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 73 of 73 2.8.5 LEGACY PLANNED UNIT DEVELOPMENT DISTRICT (LPUD) A. Purpose: The legacy planned unit development (LPUD) zoning district is intended to be utilized only for the continuation of previously established PUDs. B. Minor Plan Amendments Permitted by the Administrator: The amendment of previously approved PUDs shall be approved by the Administrator, if the amendment results in a development intensity that is no greater than the previously approved intensity in terms of total square feet, total number of units, height, and build-upon area. Additionally, a minor plan amendment shall be limited to technical considerations that could not be reasonably anticipated during the approval process, or any other change that has no material effect on the character of the approved PUD development or any of its approved terms or conditions. C. Major Plan Amendments Permitted by City Council Approval Only: All major changes not subject to B, above, shall be reviewed by the Planning Commission (PC) and approved by City Council in accordance with the procedures outlined in Section 2.8.4 B.1. D. Rezoning a PUD: Any existing LPUD may choose to rezone to a standard City zoning district by going through the rezoning process in accordance with the procedures outlined in Section 9.16. (Ord. No. O-14-23 , 9-26-2023) SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director Date: October 1, 2025 From: Curt Freese, Community Development Director To: PC ISSUE: Chapter 3 Summary of Revisions (Zoning and Land Use) Chapter 3 Standards 3.1.1 Use Permissions Defined • Revision: Added a new permission category F. T4-Neighborhood Artisan (A), allowing uses with conditions specific to the T4-NA subdistrict, with conditions listed in the "Additional Standards" section. Other T4-N uses may have special conditions for T4-NA also noted there. • Explanation: This addition adds the uses allowed in the T4-NA subdistrict which were never listed in the code. 3.2 Table of Permitted Uses • Residential Uses: • Rowhome or Townhouse: added Townhouse to Category to avoid confusion of the use allowed. • Commercial Uses: • Indoor Entertainment: Removed conditional use allowance in T3 and T3 N as not appropriate to the intent of these districts. Change to allow indoor entertainment in the T4-NA trail district, as such uses seem consistent with the potential use of existing buildings and the intent of the district. • Outdoor Entertainment: Allowed as a conditional use in the T4-NA district as again consistent with the intent of the artisan and trails district. • Inn/Motel/Hotel: Changed from — to C in T4-N, SE to P in T5-DC (previously varied). SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director • Retail & Restaurants: Changed from — to C in T4-N and T4-NA (previously —). • Animal Hospitals and Kennels: Added Use category (did not exist before) clarified it is only allowed in RMX and LI. Such uses, which create noise, smells, and outdoor areas for animals, are not consistent with the transect districts. • Changed Section 3.6.2 E to revise specific Kennel/Animal Hospital conditional use to only RMX, not T-5 UC • Industrial Uses: • Added Self Storage use category (did not exist before in table): Restricted to three districts, RMX, LI, and T4-NA. Added as a Conditional use in RMX where it will have to be screened by a liner building, E in T4-NA where there are many warehouse buildings, and a permitted use in the industrial district. Moreover, this would be consistent with the code which allows open yard storage in the same districts only, and excludes T-5 UC. • Changed use Section 3.8.2 A, to only RMX for storage. 3.2.1 Overview of Use Categories, G. RMX/T5-UC Split Zones • Revision: Added a new subsection stating that for properties split-zoned RMX/T5-UC, one district’s lot and design standards must be chosen at the development process start, with T5-UC standards applied if urban blocks from Appendix C adjoin the site. • Explanation: This clarifies development consistency in split-zoned areas, prioritizing T5- UC standards near urban blocks to maintain a cohesive urban form. It simplifies planning but may limit flexibility, impacting developers who prefer RMX’s less restrictive standards. 3.6.2 C Commercial Use Category • Cleaned up language on indoor entertainment consistent with table, allowing it in T4-NA as consistent with existing buildings and intent of trail artisan district. • Bed and Breakfast: clarified only breakfast, not other meals can be served. SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director 3.13 Overlay District Conservation Subdivision: Intent • The Conservation District aims to balance residential development with environmental preservation, targeting low-density housing (e.g., single-family homes) alongside expansive conserved areas. This reflects Beaufort’s commitment to maintaining rural character and protecting natural resources. The goal is to create an option for property owners wishing to annex and conserve land, or for owners of large tracts in the City who may wish to conserve land. 1. Street Patterns and Pedestrian and Bicycle Connectivity • a. Land Pattern: The rural style with larger lots, setbacks, and conservation subdivisions (e.g., 80% open space) minimizes environmental impact. Looping streets enhance connectivity, reducing dead-end isolation, which supports emergency access and community interaction. • b. Arterial and Collector Streets: Buffering residential lots from high-traffic roads reduces noise and safety risks, preserving the rural ambiance and protecting residents. • c. Local Streets: Rural features like borrow ditches (for drainage) and the absence of curbs/sidewalks maintain a natural aesthetic, though this may limit urban amenities. • d. Bicycle and Pedestrian Connectivity: Mandatory bike lanes and encouraged crusher fines trails (compacted gravel paths) promote active transportation and leisure, aligning with sustainable design, though the lack of sidewalks may challenge pedestrian safety. 2. Overall Layout, Density, and Process • a. Layout: Buildings set far back from streets and property lines reinforce the rural feel, reducing visual density and preserving open views. • b. Approval: Planning Commission review for city-dedicated open space ensures public benefit, adding a layer of oversight to maintain conservation goals. • c. Trail Corridor: Easement dedication along the Spanish Moss Trail integrates the CD with regional recreational networks, enhancing connectivity. SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director • d. Contiguous: Requiring contiguous property ensures cohesive conservation areas, preventing fragmented development. • e. Residual and Developed Land: The 10-acre minimum residual land (undeveloped) with development clusters (20-30%) supports a high conservation ratio, balancing housing with nature. • f. Percentage of Developable/Conservation Land: The 80/20 (no public water/sewer) or 70/30 (with sewer) split prioritizes conservation, with sewer access allowing slightly higher development (30%) under T3-N density (e.g., 2.5-4 units/acre). • g. Density: Aligning with septic or T3-N standards limits growth (e.g., 1-2 units/acre without sewer), ensuring low-density compatibility with rural settings. • h. Residual Land: Perpetual conservation status (via easements or city ownership) guarantees long-term protection, critical for wildlife and flood management in Beaufort’s environment. 3. Site Design • a. Lot Size and General Layout: • i. Priority: Preserving sensitive areas (e.g., wetlands, forests) over housing layout fosters ecological health, with compact clusters minimizing land disturbance. • ii. Minimum Lot Size: Adhering to T3-N standards (e.g., 4,000-6,000 sq ft) ensures consistency with low-density zoning. • b. Site Orientation: Designing around natural features (e.g., topography, views) and minimizing road/utility areas reduces environmental footprint and enhances aesthetics. • c. Flexibility in Lot Size: Adapting to topography and mixing housing types (e.g., larger lots near farmland) supports diversity and environmental sensitivity, improving visual access to conserved land. • d. Residual Lands: • i. Contiguity: Maximizing contiguous open space avoids unusable fragments, benefiting wildlife and recreation. SCOTT MARSHALL City Manager CITY OF BEAUFORT Community Development Department 1911 BOUNDARY STREET BEAUFORT, SC 29902 (843) 525-7011 FAX (843) 986-5606 CURT FREESE Community Development Director • ii-iii. Connectivity: Allowing trails and linking with adjacent conserved land enhances usability and ecological corridors. • iv-v. Uses: Limiting structures to 5% and restricting them to resident use (e.g., trails, agricultural sheds) preserves the conservation focus. • vi-vii. Exclusions: Excluding roads/parking (except in 80/20 ratios) and prohibiting subdivision maintains open space integrity. • viii-ix: Perpetual easements or city dedication, with no subdivision, ensure long-term protection. • e. Design Requirements: • i-iii: Siting structures at farmland edges or near existing development creates cohesive fields and minimizes habitat fragmentation. • iv-v: Using fence rows and minimizing driveways reduces visual and ecological disruption, as illustrated in Figure 5-1. Impact • Developers: Face constraints with high conservation ratios (70-80%) and rural design requirements, potentially increasing costs for larger lots and trails but offering flexibility in layout. • Community: Benefits from preserved natural areas, enhanced trail access (e.g., Spanish Moss Trail), and low-density living, though limited sidewalks may affect accessibility. • Environment: Significant protection of residual land (10+ acres) supports biodiversity and flood resilience. Beaufort, South Carolina, The Beaufort Development Code 3: LAND USE PROVISIONS Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:08 [EST] (Supp. No. 1) Page 1 of 58 3: LAND USE PROVISIONS 3.1: APPLICABILITY 3.1.1 USE PERMISSIONS DEFINED The use table in Section 3.2 assigns 1 of 6 permissions to each use in each district as follows: A. Permitted Use (P): The use is permitted by-right, with no additional conditions or requirements. B. Conditional Use (C): The use is permitted by-right, provided that the additional use conditions set forth in this article are met. 1. The specified standards are intended to ensure that these uses are compatible with other development permitted within the districts. 2. Approval procedures for conditional uses are in Section 9.4.2 (Zoning Permit.) C. Special Exception (SE): The use is permitted only when a Special Exception has been approved. 1. Special Exceptions are required for uses that may be compatible with other uses permitted in a district, but which, because of their unique characteristics or potential impacts on the surrounding neighborhood and/or the city as a whole, require individual consideration in their location, design, configuration, and/or operation at the particular location proposed. 2. All applications for Special Exceptions shall, at a minimum, meet the standards for the district in which they are located and the additional standards set forth in this article for that use. There may also be specific building design standards that must be met (Section 4.5). 3. Approval procedures for Special Exceptions are found in 9.13. D. In Existing Facilities Only (E): The use is permitted only in existing buildings or facilities and in any expansions that do not increase the size of the facility structure by more than 50%. E. Retail Frontage Overlay Required (RF): Where a block face is designated on the zoning map as a Retail Frontage overlay, the building(s) with direct access to the designated fronting street is permitted to be occupied by certain commercial uses as indicated in the use table. F. T4-Neighborhood Artisan (A): This use is permitted with conditions only in the T4 -Neighborhood Artisan (T4-NA) District. Conditions may be listed in the "Additional Standards" section as appropriate. Other uses permitted in the general T4-N district may have special conditions for T4 -NA; those conditions are also listed in the additional standards section as appropriate. G. Prohibited Uses (—): The use is prohibited in the specified district. - 3: LAND USE PROVISIONS 3.2: TABLE OF PERMITTED USES Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 2 of 58 3.2: TABLE OF PERMITTED USES Land uses in transect-based and conventional districts shall be permitted in accordance with the table below. Special provisions related to uses in the AICUZ Overlay District are in Section 2.7.4. The zoning designation of water is the same as the land it is adjacent to. P=Permitted Use C=Conditional Use SE=Special Exception E=in Existing Building/Facility Only RF = Retail Frontage Only A=T4-Neighborhood Artisan subdistrict Only — = Prohibited use DISTRICT T1 T3- S T3- N T4- HN T4- N T4- NA T5- DC T5- UC RMX LI IC MHP ADD'L STAN- DARDS WHEN APPLI- CABLE RESIDENTIAL 3.3 Household Living Single-Family Dwelling — P P P P P E E E E E — — 2- or 3-Unit Dwelling — — C P P SE P P — — P — 4.5.5 Rowhome or Townhouse — — — — C SE P P P — P — 4.5.6 Apartment House (a.k.a. Multifamily Dwelling - 4+ units) — — — — C — P P P — P — 4.5.7 Home Occupation - Minor — C C C C P P P P — — — 3.3.2.D Home Occupation - Major — SE SE SE C P P P — — — — Live-Aboard Boat C C C C C C C C C C C C 3.3.2.D Live/Work Unit — — — — C P P P P C P — 4.5.8 Manufactured Home — — — — — — — — — — — C 3.3.2.G Group Living Group Dwelling (≤ 8 residents) — — — — P — P P P — — — — Group Dwelling (> 8 residents) — — — — SE — SE P P — P — — PUBLIC AND CIVIC 3.4 Civic/Government Facilities C — SE SE P P P P P P P — 3.4.2.A Educational Facilities College/University/Trade/Vocational — — — — C — P P P C P — 3.4.2.B.1 School, Public or Private — C C C P C P P P — P — 3.4.2.B.2 Parks and Open Space Cemetery C E E E E E E E C E E E 3.4.2.C Park/Open Space P P P P P P P P P P P P 7.4 Formatted Table - 3: LAND USE PROVISIONS 3.2: TABLE OF PERMITTED USES Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 3 of 58 INSTITUTIONAL 3.5 Community Service — SE SE SE P P P P P SE P — — Day Care Facility Family Day Care Home (≤ 6 clients) See Home Occupation — Minor Group Day Care Home (7-12 clients) & Commercial Day Care Center (>12 clients) — — SE C C C P P P P P — 3.5.2.A Treatment Facility — — — — SE — SE SE P — SE — — Health Care Facilities — — — — — — — P P — P — — Religious Institution — C C P P P P P P — P — 3.5.2.B COMMERCIAL 3.6 Entertainment Indoor Entertainment — C C — C P P P P P P — 3.6.2.A Outdoor Entertainment — — — — C C P P P — P — 3.6.2.A Sexually-Oriented Business — — — — — — — — — C — — 13.2.1 Office — — — — P C P P P P P — 3.6.2 A— Overnight Guest Accommodation Bed and Breakfast — — SE SE P SE P P — — — — 3.6.2.C.1 Short-Term Rental — C C C C C C C — — C — 3.6.2.C.2 Inn/Motel/Hotel — — — — C SE P P P — — — 3.6.2.C.3 Recreational Vehicle Park — — — — — — — — SE — — — — Retail & Restaurants — — — — C C C C P — C — 3.6.2.D Animal Hospitals and Kennels — — — — — — — — P P — — 3.6.2 E VEHICLE- AND BOAT-RELATED USES 3.7 Vehicle and Boat Sales and Rental — — — — A — — C P — — — 3.7.2.A Drive-Thru Facility — — — — — — — C C SE — — 3.7.2.B Fuel Sales/Car Wash — — — — — — — C C P — — 3.7.2.C Vehicle Service and Repair — — — — C — — C C P — — 3.7.2.D Parking, Commercial, Surface — — — — C — C P P P P — 3.7.2.F Parking, Structure — — — — RF — P P P P P — — Passenger Terminals — — — — — — — SE P P — — 3.7.2.G Water/Marine-Oriented Facilities P — — — P — P P — — P — — INDUSTRIAL 3.8 Aviation Services — — — — — — — — — P — — — Light Industrial Services — — — — A C — C C P — — 3.8.2.A Manufacturing and Production Services — — — — A E — — C P — — 3.8.2.B Truck Terminal — — — — — — — — — P — — — Self Storage — — — — — E — — C P — — 3.8.2 A COMMUNICATION & INFRASTRUCTURE USES 3.9 - 3: LAND USE PROVISIONS 3.2: TABLE OF PERMITTED USES Beaufort, South Carolina, The Beaufort Development Code Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 4 of 58 Major Infrastructure/Utilities — — — — A — — — SE P — — 3.9.2.A Minor Infrastructure/Utilities E C C C C C C C C P C — 3.9.2.B Waste Related Services — — — — — — — — — SE — — 3.9.2.C Wireless Communications Facility — — — — — — — — C C — — 3.9.2.D FORESTRY, AGRICULTURE, HORTICULTURE C C C C C C C C C C C — 3.10 3.2.1 OVERVIEW OF USE CATEGORIES A. Definition of Use Category: See Section 13.1 (Definitions of Specialized Terms). B. Basis for Classification: Use categories classify land uses and activities into categories based on common functional, product, or physical characteristics. Characteristics include the type and amount of activity, the type of customers or residents, how goods or services are sold or delivered and site conditions. The use categories provide a systematic basis for assigning present and future land uses into appropriate Districts. C. Principal Uses: Principal uses are assigned to the category that most closely describes the nature of the principal use. The "Characteristics" subsection of each use category describes the common characteristics of each principal use. 1. Developments with Multiple Principal Uses: When all principal uses of a development fall within one use category, the entire development is assigned to that use category. When the principal uses of a development fall within different use categories, each principal use is classified in the applicable category and each use is subject to all applicable regulations for that category. D. Accessory Uses: Accessory uses are allowed by-right in conjunction with a principal use, unless otherwise stated in this Code. Also, unless otherwise stated, accessory uses are subject to the same regulations as the principal use. Common accessory uses are listed as exam ples in the use category descriptions. See Section 3.12 for additional standards for accessory uses and structures. E. Use of Examples: The "Examples" subsection of each use category lists common examples of uses included in the respective use category. The names of these sample uses are generic. They are based on common meanings and not on what a specific use may call itself. For example , a use that calls itself a "wholesale warehouse," but sells mostly to consumers, is included in the "Retail Sales and Service" category rather than the "Wholesale Sales" category. This is because the actual activity on the site matches the description of the "Retail Sales and Service" category. F. Similar Use Interpretation Criteria: The following considerations shall be used in making similar use interpretations: 1. The actual or projected characteristics of the activity in relationship to the stated characteristics of each use category. 2. The relative amount of site area or floor space and equipment devoted to the activity. 3. Relative amounts of sales from each activity. 4. The customer type for each activity. 5. The relative number of employees in each activity. Created: 2023-12-08 08:25:06 [EST] (Supp. No. 1) Page 5 of 58 6. Hours of operation. 7. Building and site arrangement. 8. Vehicles used with the activity. 9. The relative number of vehicle trips generated by the use. 10. How the use advertises itself. G. RMX/T5-UC SPLIT ZONES: 1. In properties split zoned RMX/T5-UC, one district and corresponding lot and design standards shall be utilized at beginning of the development process. This process shall be followed with commercial and mixed uses developments, with outlots. If urban blo cks and lots/street sections, as found in Appendix C, exist adjacent to the RMX/T-5UC district being developed, T-5 UC development standards shall be followed. 3.3: RESIDENTIAL USES 3.3.1 OVERVIEW OF RESIDENTIAL USE CATEGORIES A. Household Living: 1. Characteristics: Household Living is characterized by the residential occupancy of a dwelling unit by a household. Tenancy is arranged on a month -to-month or longer basis. 2. Accessory Uses: Accessory uses include recreational activities, hobbies, accessory dwelling units, enclosed storage, and parking of the occupants' vehicles. Home Occupations are accessory uses that are subject to additional regulations set forth in Section 3.3.2 D. 3. Examples: Examples include single-family dwellings, two-family dwellings, triplexes, condominiums, townhouses, and other multi -family dwellings, upper floor residential, retirement center apartments, some congregate care facilities, and manufactured housing and oth er structures with self-contained dwelling units. 4. Exceptions: Living in a dwelling unit where units are rented for less than 30 days is classified in the Overnight Guest Accommodations category. B. Group Living: 1. Characteristics: Group Living is characterized by the residential occupancy of a structure by a group of people who do not meet the definition of "household living." The size of the group may be larger than the average size of a household. Tenancy is arranged on a monthly or longer basis. Uses where tenancy may be arranged for a shorter period are not considered residential. They are considered to be a form of transient lodging (see "Overnight Accommodations" — Section 3.6.1 C. — and "Community Service" — Section 3.5.1 A. — categories). Generally, group living structures have a common eating area for residents. The residents may receive care, training, or treatment. 2. Accessory Uses: Accessory uses include recreational facilities, dining facilities, and parking of vehicles for occupants and staff. 3. Examples: Examples include group dwellings, dormitories, fraternities and sororities, nursing homes, assisted living facilities, and monasteries and convents. Formatted: Font: Bold Formatted: Indent: First line: 0.5" Formatted: Indent: Left: 0.5" Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 6 of 58 4. Exceptions: a. Lodging where tenancy may be arranged for periods of less than 30 days is classified in the Overnight Guest Accommodations category. b. Lodging where the residents meet the definition of a household, and where tenancy is arranged on a month to month basis, or for a longer period, is classified as Household Living. c. Congregate Care Facilities, where individual units meet the definition of a dwelling unit in Article 13, are classified as Household Living. d. Monasteries and convents affiliated with, and attached to — or on the same campus as — a church are considered Religious Institutions. 3.3.2 ADDITIONAL STANDARDS FOR RESIDENTIAL USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. 2—3 Units Dwelling: See Section 4.5.5. B. Rowhome (syn. townhome, townhouse, rowhouse): See Section 4.5.6. C. Multi-family Dwelling: See Section 4.5.7. D. Home Occupations: Home Occupations shall be separated into 2 categories and permitted subject to an annual business license, issued by the City of Beaufort and the following provisions. 1. Home Occupation - Minor: A Minor Home Occupation shall be deemed an accessory use, and must meet the following standards: a. Incidental: Such use shall be clearly incidental and secondary to the principal use of the dwelling. b. Access: Entrance to the home office portion of the dwelling shall be from within the dwelling, and not through a new outside entrance, except where this provision conflicts with the requirements of the South Carolina Department of Health and Environmental Control (DHEC). c. Clients: i. Instruction in music, dancing and similar services shall be limited to 2 clients at a time. ii. Family Child Care Home is limited to 6 or fewer clients. d. Employees: Employees are limited to those persons who reside on the premises. 2. Home Occupation - Major: a. Employees: A maximum of 2 employees who are not residents of the household may work on-site. b. Process: These are permitted by Special Exception (Section 9.13). 3. Home Occupation Standards: a. General to All Home Occupations: Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 7 of 58 i. Disturbance: Such use shall create no disturbing or offensive noise, vibration, smoke, dust, odor, heat, glare, unhealthy or unsightly conditions, visual or audible interference in any radio or television receivers off the premises, traffic, or parking problems. ii. Hours: Activities involving visitors/clients shall occur only between 8 a.m. and 8 p.m. When Family Day Care Home is a Home Occupation -Minor, it is exempt from this standard. iii. Parking: Off-street parking shall be provided in accordance with the standards of Section 5.7 for the type of home occupation maintained. The off -street parking spaces required for the home business shall be maintained in addition to the space or spaces required for the residence itself. No parking spaces, other than driveways, may be located in the required front yard setback. Such use shall not result in off-street parking of more than 3 vehicles at any one time not that are owned by members of the occupant household. iv. Vehicles: Only passenger vehicles with a size not exceeding classification as light duty vehicles (8,500 pounds or less), shall be permitted in connection with the home occupation. v. Trailers: One vehicle trailer, no more than 12 feet in length, is permitted as part of such use. The trailer shall not be parked in the street right -of-way or in the front yard, unless it is parked in a driveway. vi. Specialized Use Standards: a. Barber Shop/Beauty Parlor: This use shall be licensed and operated according to the standards set by the South Carolina Department of Labor, Licensing, and Regulation, and shall be limited to 2 chairs. The applicant shall certify that the proposed use is not prohibited by any covenant or deed restriction on the property. b. Event Venue: A private home may be used as an event venue and considered a home occupation-major if not more than 1 event occurs per month, on average, with each event lasting no longer than 2 days. Events shall be limited to 501(c)3 non-profit functions. b. Specific to all Home Occupations: i. Outdoor Activities: Outdoor operations and storage related to the home occupation are prohibited. ii. Signs: No more than one sign or name plate not exceeding 1.5 square feet in area is permitted. No freestanding, illuminated, or animated sign shall be posted. If a home occupation is located in a bed and breakfast establishment, then only one sign shall be permitted for both uses. iii. Display/Sales: Products that have been produced on premises may be displayed on front porches and cover up to 25% of the floor/wall area of the porch. Items that are offensive and violate provisions of Section 1.2 of this Code, are not permitted. Display of merchandise in the yard is not permitted. iv. Sales: Only articles made on the premises, with the exception of antiques, may be sold. Non-durable articles (consumable products) that are incidental to the service, that is the principal use in the home occupation may be sold on the premises. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 8 of 58 v. Maximum Size: The home occupation shall occupy a maximum of 25% of the floor area of the principal dwelling. There is no maximum percentage of floor area for accessory structures. 4. Exclusions to Home Occupations: No home occupation shall be permitted that results in any of the following: a. Makes internal or external alterations inconsistent with the residential use of the building. b. Is visible from the street. c. Generates traffic, parking, sewage, or water use in excess of what is normal in the residential neighborhood. d. Creates a hazard to persons or property. e. Results in electrical interference. f. Results in the outside storage or display of anything. 5. Prohibited Home Occupations: The following are prohibited as Home Occupations (Minor or Major): a. Automobile and/or body and fender repair. b. Restaurants. c. Uses that entail boarding, harboring, training, raising, or treating dogs, cats, birds, or other animals on-site. d. Body piercing and tattoo facilities. e. Storage. E. Live-Aboard Boat: Such boats shall be located within a marina permitted by the South Carolina Department of Health and Environmental Control Office of Ocean and Coastal Resource Management (SCDHEC-OCRM) or attached to a mooring ball located within a mooring field permitted by SCDHEC- OCRM. F. Live-Work Unit: See Section 4.5.8. G. Manufactured Home: Manufactured homes are permitted as part of a manufactured home park only. Manufactured home parks standards are listed in Section 4.6.5. 3.4: PUBLIC AND CIVIC USE CATEGORIES 3.4.1 OVERVIEW OF PUBLIC AND CIVIC USE CATEGORIES A. Civic Facility: 1. Characteristics: This category includes public or quasi-public facilities open to the general public that serve a cultural, educational, and/or social function in the community. 2. Accessory Uses: Accessory uses include retail uses such as a gift/book shop, restaurant, etc. 3. Examples: Examples include aquariums, arboretums, art galleries and exhibitions, civic theaters, facilities for live theater and concerts, historic sites and exhibits, libraries, museums, planetariums, and zoos. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 9 of 58 B. Government Facilities: 1. Characteristics: Government facilities include offices, storage, maintenance and other facilities for the operation of local, state, or federal government. 2. Accessory Uses: Accessory uses include storage, maintenance and fueling facilities, satellite offices, and parking areas. 3. Examples: Examples include government offices, government/public buildings, government/public land, jails, City Hall, maintenance facilities, fire, police, and emergency medical and ambulance stations, detention centers, lifeguard services, and post offices. 4. Exceptions: a. State, county or city parks are classified as Parks and Open Space. b. Water and wastewater facilities, gas, electric and other infrastructure services — whether public or private — are classified as Utilities. c. Waste and recycling services are classified as Waste -Related Services. C. Educational Facilities: 1. Characteristics: This category includes public and private schools at the primary, elementary, middle, junior high, or high school level that provide state -mandated basic education. This category also includes colleges and other institutions of higher learning that offer courses of general or specialized study that lead to a degree. Colleges tend to be in campus -like settings or on multiple blocks. 2. Accessory Uses: Accessory uses at schools include play areas, cafeterias, temporary classroom buildings, recreational and sport facilities, auditoriums, and before -or-after school day care. Accessory uses at colleges include offices, housing for students, food service, l aboratories, health and sports facilities, theaters, meeting areas, parking, and maintenance facilities. 3. Examples: Examples include public and private daytime schools, boarding schools, military academies, universities, colleges, community colleges, business school, trade and vocational schools, nursing and medical schools that are not accessory to a hospital, and sem inaries. 4. Exceptions: a. Preschools not affiliated with and attached to primary schools are classified as Day Care uses. b. Learning centers and other similar facilities that do not provide a state -mandated curriculum are classified as Retail Sales and Service. D. Parks and Open Areas: 1. Characteristics: Parks and open areas focus on natural areas consisting mostly of vegetative landscaping or outdoor recreation, community gardens, and public squares. These areas tend to have few structures. 2. Accessory Uses: Accessory uses include club houses, maintenance facilities, administrative offices for city park personnel, police substations, concessions, single -family and two-family caretaker's quarters, and parking. 3. Examples: Examples include parks, shoreline protection areas, beach accesses, publicly -owned golf courses, public swimming pools, public tennis courts, publicly -owned ballfields and basketball courts, cemeteries, open space, public squares, plazas, recreational tra ils, historically significant sites and structures, botanical gardens, nature preserves, and wildlife refuges. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 10 of 58 4. Exceptions: Privately owned facilities, such as golf courses, tennis courts, pools, etc. are classified as Entertainment uses. 3.4.2 ADDITIONAL STANDARDS FOR PUBLIC AND CIVIC USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Civic Facilities: The size of structures shall be limited to a 2,500 square foot footprint. B. Educational Facilities: 1. School, College/University/Trade/Vocational: a. Site Design: Campuses must be designed to address the public realm with either buildings or public spaces. Service areas and parking must be screened from the street. b. Specific to LI: Trade/Vocational schools and branches of College/University facilities are permitted if they relate to an Industrial function that is permitted in this district. 2. Schools (Public or Private): a. Neighborhood Connectivity: Vehicular and pedestrian connectivity to surrounding residential areas is required. Where a full vehicular connection is impractical, a multi -use trail connection shall be provided. b. On-Site Circulation: Pedestrians and bicyclists must have a designated safe path between the adjacent roads, school drives, parking areas, and the school building. c. Temporary Classrooms: The siting of all temporary classrooms shall be approved by the Administrator. d. Lot Size Minimum: 20,000 square feet. e. Location, Specific to T3 and T4-HN: No structure on the property may be closer than 25 feet to any internal side or rear property line if adjacent to T3 or T4 -HN zoning district. C. Parks and Open Space: 1. Cemetery: a. Size: Minimum of 1 acre. b. Accessory Uses: One dwelling unit for a caretaker is permitted on -site as an accessory use. No crematorium shall be permitted. 3.5: INSTITUTIONAL USE CATEGORIES 3.5.1 OVERVIEW OF INSTITUTIONAL USE CATEGORIES A. Community Service: 1. Characteristics: Community Services are uses of a public, nonprofit, or charitable nature that provide a local service to people of the community. Typically, they provide the service on -site or have employees at the site on a regular basis. The service is ongoing, not jus t for special events. Formatted: List Paragraph, Indent: Left: 0.75" Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 11 of 58 Community centers or facilities that have membership provisions must be open to the general public to join at any time (for instance, any senior citizen could join a senior center). The use may provide special counseling, education, or training of a public , nonprofit, or charitable nature. Overnight stays are not permitted in these facilities. 2. Accessory Uses: Accessory uses include offices, meeting areas, food preparation areas, parking, health and therapy areas and athletic facilities. 3. Examples: Examples include senior centers, community centers, public information facilities, visitors' center, civic/business association, the Salvation Army, youth club facilities, and hospices and social service facilities. 4. Exceptions: a. Private lodges, clubs, and private or commercial athletic or health clubs are classified as Retail Sales and Service. b. Parks are classified as Parks and Open Areas. c. Uses where tenancy is arranged on a month -to-month basis or for a longer period are residential and are classified as Household or Group Living. B. Day Care: 1. Characteristics: Day care uses provide care, protection, and supervision for children or adults on a regular basis, away from their primary residence, for less than 24 hours per day. 2. Accessory Uses: Accessory uses include offices, recreation areas and parking. 3. Examples: Examples include preschools, nursery schools, child care centers, latch key programs, and adult day care programs. 4. Additional Standards: A Family Day Care Home, where in-home care for six or fewer individuals is provided, is considered a minor home occupation (accessory use) and is subject to the standards of Section 3.3.2 D. 5. Exceptions: Day care does not include preschools operated within public or private schools, or facilities operated in connection with an employment use, shopping centers, or other principal use, where children are cared for while parents or guardians are occupied on the premises or in the immediate vicinity. C. Health Care Facilities: 1. Characteristics: Health care facilities include uses that provide medical or surgical care to patients, and offer overnight care. 2. Accessory Uses: Accessory uses include outpatient clinics, offices, meeting areas, cafeterias, laundries, parking, maintenance facilities, educational facilities and housing facilities for staff or trainees. 3. Examples: Examples include medical centers, hospitals, health center, and medical laboratories and clinics. 4. Exceptions: a. Uses that provide exclusive care and planned treatment or training for psychiatric, alcohol, or drug problems, where patients are residents of the program, are classified as Treatment Centers. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 12 of 58 b. Medical clinics that provide care where patients are generally not kept overnight are classified as Offices. D. Treatment Centers: 1. Characteristics: Residential care facilities provide a variety of services, including housing and care related to treatment programs. 2. Accessory Uses: Accessory uses include club houses, maintenance facilities, administrative offices, police substations, concessions, single -family and two-family caretaker's quarters, and parking. 3. Examples: Examples include some group homes for the physically disabled, mentally disabled or emotionally disturbed, homeless shelters, some residential programs for drug and alcohol treatment, and alternative or post-incarceration facilities. 4. Exceptions: Congregate care facilities where individual units meet the definition of a dwelling unit are classified as Household Living. E. Religious Institutions: 1. Characteristics: Religious institutions primarily provide meeting areas for religious activities. 2. Accessory Uses: Accessory uses include Sunday school facilities, playgrounds, child care while parents or guardians are on the premises, parking, cemeteries, caretaker's housing, and group living facilities such as convents, fairs and bazaars up to 3 days, health and the rapy areas, and other use directly related to the mission of religious institutions, whether or not such uses require a business license, on the condition that such uses are located in a building owned by a religious institution. 3. Examples: Examples include churches, temples, synagogues and mosques. 4. Exceptions: a. Preschools and infant day care are classified as Day Care uses. b. Schools are classified as Schools. 3.5.2 ADDITIONAL STANDARDS FOR INSTITUTIONAL USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Day Care Facility: 1. Specific to T4-HN: All day care facilities, except for Family Day Care Home, shall be owned and operated by Religious Institutions or Community Service Facilities. 2. Specific to T4-N: a. Number: Limited to one per block (300 feet radius). b. Buffering: A landscaped hedge or fence at least 4 feet in height shall be provided along any rear or side property line adjoining existing single -family residential development. 3. Exception: Family Day Care Home (6 or fewer clients) is considered a Home Occupation -Minor. See Section 3.3.2 D. B. Religious Institution: Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 13 of 58 1. Lot Size Minimum: 20,000 square feet. 2. Location, Specific to T3 and T4-HN: No structure on the property may be closer than 25 feet to any internal side or rear property line if adjacent to T3 or T4 -HN zoning district. 3.6: COMMERCIAL USE CATEGORIES 3.6.1 OVERVIEW OF COMMERCIAL USE CATEGORIES A. Entertainment: 1. Characteristics: Entertainment uses are large, generally commercial uses that provide continuous recreation or entertainment-oriented activities. 2. Accessory Uses: Accessory uses include restaurants, concessions, parking, and maintenance facilities. 3. Examples: Examples include indoor continuous entertainment activities, such as bowling alleys, game arcades, pool halls, dance halls, banquet facilities, indoor firing ranges, theaters, private membership clubs and lodges, health clubs and gyms, privately -owned golf courses, privately- owned marinas, miniature golf facilities, privately -owned swimming pools, privately-owned tennis facilities (indoor and outdoor), and privately -owned active sports facilities (indoor and outdoor), such as ballfields and basketball courts. 4. Exceptions: a. Exhibition and meeting areas with less than 20,000 square feet of total event area are classified as Retail Sales and Service. b. Publicly owned recreational facilities, such as golf courses and tennis courts, are classified as Parks and Open Areas. B. Office: 1. Characteristics: Office uses are characterized by activities conducted in an office setting and generally focus on business, government, professional, medical, or financial services. 2. Accessory Uses: Accessory uses include cafeterias, health facilities, parking for vehicles classified as light duty vehicles (8,500 pounds or less), or other amenities that are primarily for the use of employees in the firm or building. 3. Examples: Examples include professional services such as lawyers, accountants, engineers, and architects, medical offices for doctors, psychologists, acupuncturists, physical therapists and dentists, emergency medical care offices, financial businesses such as lend ers, brokerage houses and financial planners, insurance agencies, real estate agencies, data processing offices, sales offices, public utility offices, radio and television studios, medical and dental clinics and labs, and blood collection facilities. 4. Exceptions: a. Offices that are part of and located with a principal use in another category are considered accessory to the firm's primary activity. Headquarters offices, when in conjunction with or adjacent to a principal use in another category, are considered part o f the other category. b. Contractors and others who perform services off -site are included in the Office category if there is no parking of vehicles over 8,500 pounds on the site, if equipment and materials Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 14 of 58 are not stored outside, and if and fabrication, services, or similar work is not carried on at the site. C. Overnight Guest Accommodations: 1. Characteristics: Overnight guest accommodations are dwelling units arranged for short -term stays of less than 30 days for rent, lease, or interval occupancy. 2. Accessory Uses: Accessory uses include pools and other recreational facilities, parking, limited storage, and offices. 3. Examples: Examples include bed and breakfast establishments, hotels, motels, inns, short -term rentals, and interval occupancy facilities, central reception, and check -in facilities. D. Retail and Restaurants: 1. Characteristics: Restaurants are establishments that sell food and beverages for consumption on - or off-premises. Retail sales and service businesses are involved in the sale, lease, or rent of new or used products to the general public. They may also provide personal ser vices or entertainment, or provide product repair or services for consumer and business goods. 2. Accessory Uses: Accessory uses include decks and patios, and outdoor cooking (for restaurants), offices, storage of goods, manufacture or repackaging of goods for on -site sale, and parking. 3. Examples: Examples include uses from six groups: a. Sales-Oriented: Stores selling, leasing, or renting consumer, home and business goods including art, art supplies, bicycles, books, candy, clothing, dry goods, antiques, hobby supplies, tobacco, toys, drugs/pharmacy, electronic equipment, fabric, florist, furniture, garden supplies, gifts, groceries, hardware, hats, health food, home improvements, household products, jewelry and watches, liquor, magazines, music, newspapers, pets, pet food, photographic supply/cameras, plants, produce, stationary, shoes and videos, and food. b. Personal Service-Oriented: Banks and savings and loans, bakeries, barber/beauty shop, body piercing, catering establishments, locksmith/gunsmiths, dry cleaning and laundry drop-off, funeral homes, mortuaries, laundromats, photographic studios, photocopies, photo development and drop-off, quick-print and blueprint services, tanning and personal care services, tattoos, martial arts facilities, acting, art, dance or music classes, secretarial/answering services, taxidermists, animal hospitals, kennels and v eterinarians. c. Repair-Oriented: Repair of TVs, bicycles, clocks, watches, shoes, guns, canvas products, appliances and office equipment, alterations and tailoring establishments, locksmith, and upholsterer. d. Artisan-Oriented: Preparation, display, classes/education, performance - and sale of individually crafted artwork and visual and performing arts such as, jewelry, furniture, sculpture, pottery, leathercraft, textiles, drawing, photography, music, theater, painting, sculpture and writing. e. Trail-Related: This limited subset of Retail Sales and Service specifically caters to the Spanish Moss Trail. Retail uses include the sale, rental, and/or repair of outdoor recreational equipment, goods, or clothing. f. Restaurants: Includes sit-down restaurants, cafes, coffee shops, drive -ins, fast food establishments, microbreweries, craft distilleries, pubs, yogurt or ice cream shops, and pizza delivery. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 15 of 58 4. Exceptions: a. Laundry and dry-cleaning plants, and self-service storage facilities, are considered Light Industrial Services. b. Lumber yards and other building material sales that sell primarily to contractors and do not have a retail orientation are classified as Wholesale Sales. c. Repair and service of consumer motor vehicles, motorcycles and light and medium trucks is classified as Vehicle Service. d. Restaurants with drive-thrus are classified as Drive-Thru Facility uses. Restaurants located in T4-NA are considered Trail-Related uses. Food trucks are classified as Temporary Uses. 3.6.2 ADDITIONAL STANDARDS FOR COMMERCIAL USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Entertainment Uses (Indoor and Outdoor): 1. Specific to T3: Indoor and outdoor entertainment are permitted if the property is owned by a neighborhood association or property owners' association, and if the use is owned and managed by that association. 2. Specific to T4-N: Indoor Entertainment shall be limited to 2,500 SF in a standalone building. Indoor entertainment is a permitted use when located in a unless it is part of a mixed-use development or building. 3. Specific to T4-NA: Indoor Entertainment, Community Service and Office uses are permitted uses. 34. Specific to T4-N and T5-UC: Outdoor Entertainment is permitted on parcels 7 acres or larger. B. Sexually-Oriented Businesses: See Section 13.2.1. C. Overnight Guest Accommodation: 1. Bed and Breakfasts (B&B): a. Number of Rental Rooms: 10 maximum, not including the caretaker's quarters. b. Signs: Total sign area for all signs advertising the B&B shall not exceed 5 square feet. All signs shall be constructed of wood or other durable non -plastic materials. c. Parking: One space per room, plus 1 space for the resident manager shall be provided on - site. Formalized on-street parking spaces meeting the requirements of Section 5.7.4 B. may count towards this requirement. d. Spacing: There shall be no other B&B in a T3 or T4 -HN zoning district located within 500 feet of a proposed B&B in either of these districts. Distances shall be measured from the property line. e. Meals: Only breakfast shall be served, and Nono mealsbreakfast will be served to anyone other than registered guests, except as provided for in Section 3.6.2 C.1.f. below. No variances from this condition shall be permitted. f. Events: Business meetings, receptions, teas, and other events are permitted, provided that the events are hosted for registered guests. This shall apply to all B&Bs established under the Beaufort Code. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 16 of 58 g. Operation: B&Bs shall be operated by a resident manager living on the premises. 2. Short Term Rental: a. Specific to T3-S, T3-N, and T4-HN: Short term rentals, where the owner does not live on the premises, are limited to 6% of the lots in the neighborhood as shown on the City of Beaufort Neighborhoods Map zoned T3-S, T3-N, and/or T4-HN with the following exceptions: i. Structures on the City's List of Vacant and Abandoned Structures being rehabilitated for use as a short term rental; and ii. Short term rentals are prohibited in The Point neighborhood, as shown on the City of Beaufort Neighborhoods Map. b. Minimum Stay: 2 nights. c. Permitted Rental Types: i. Rental of the primary dwelling. ii. Rental of an accessory dwelling. iii. Rental of a portion of a primary dwelling. iv. Rental of a boat in an approved marina. d. Parking: Parking shall be provided on-site and located to the side or rear of the dwelling. On-site parking shall be clearly delineated with an improved surface such as pavement, gravel, or another method approved by the administrator. If formalized parking is pro vided on the street(s) adjacent to the primary or accessory unit, this may be utilized in lieu of on - site parking. e. Rental Agreement: The applicant shall provide a copy of the rental agreement that will be used. The rental agreement shall specify the following: i. The minimum stay. ii. The maximum number of guests—which shall be based on the number of beds in the unit. For Primary house rentals, the number of adult guests is limited to 2 per bedroom. For Carriage House rentals, the total number of adult guests is limited to 4. iii. The maximum number of vehicles permitted at the unit —which shall be based on the number of bedrooms and the design of the driveway. For Primary house rentals, the number of vehicles is limited to 1 per bedroom. For Carriage House rentals, the total number of adult guests is limited to 2. iv. Where guests are to park. Where no formalized on -street parking is available, the agreement shall specify that guests are to park on -site and not in the street. v. That the City's noise ordinance applies between 9:00 p.m. and 8:00 a.m. vi. Prohibit large gatherings such as weddings and reunions unless specifically approved by the City. vii. Pets, if permitted, are not to be left outside unattended. f. Property Management Plan: A property management plan shall be developed and approved by the administrator. The property management plan shall identify a property manager. Where the property owner does not live on the premises, the property manager must be available to appear on the premises to respond a complaint within three hours of Formatted: List 4 Formatted: List 4 Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 17 of 58 being notified by the administrator. Where the property owner lives on the premises, a back-up property manager must be identified unless the owner certifies the unit will not be rented when the owner is out of town. The administrator shall be notified whe n management of the unit changes. Failure to comply with the approved property management plan shall result in the revocation of the zoning permit (Section 9.4). g. Signs: No on-site signs shall be permitted. h. Rental Rules: Rental rules, including use of the sanitation and recycling roll -carts, and emergency contact information including the police non -emergency number, shall be posted in a conspicuous location in the unit. i. Monitored Fire Alarm: A monitored fire alarm is required for all units except boats. Boats are required to provide documentation that a Coast Guard Auxiliary Safety Vessel Check has been performed is required. The Vessel Safety Check can be arranged through this link: http://www.cgaux.org/vsc . Existing facilities not meeting this requirement shall be brought into conformance within 6 months of the date of adoption of this Code. j. Outside Approvals Required: For properties located in a neighborhood with a property owners' association, written confirmation from the association president that short -term rentals are permitted in the neighborhood is required. In multifamily structures, written approval from the property management association is required. For boats in an approved marina, written permission from the marina manager is required. k. Safety Inspection and Licensing: A Safety Inspection shall be conducted before the Business License for the facility is issued. The facility shall comply with all business license, revenue collection, and health laws of the City of Beaufort, Beaufort County and the State of South Carolina. l. Unlicensed Units: For units that are found to be operating without approval of the City, the short term rental application fee shall be $1,000. If the property owner chooses not to submit a short term rental application within 60 days of being notified by the City of being in violation of the ordinance, a short term rental application shall not be approved for a period of 2 years. 3. Inn/Hotel/Motel: a. Specific to T4-N: i. Inns up to 10 rooms are permitted. ii. Inns with 11—24 rooms are permitted in retail frontage overlay areas. b. Specific to T4-NA: This use is prohibited. D. Retail and Restaurants: 1. Specific to T4-N only: Except for Animal Hospitals/Kennels, Restaurants and Retail are permitted only in Retail Frontage Overlay Districts, and in the T4 -NA district per the conditions below. Animal Hospitals/Kennels shall follow the Conditions for T5 -UC. 2. Specific to T4-NA: The only types of gGeneral retail/service uses are permitted arein the Artisan- Oriented and Trail-Related T4-NA District uses. The following conditions apply: a. Freestanding signs are limited to one per lot, with a maximum size of 5 square feet. b. No outside amplified music is permitted. c. No alcohol sales are permitted. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 18 of 58 d. New construction and exterior changes to existing structures to accommodate such uses shall be subject to Article 4 (Building Design and Infill Standards) of this Code. e. Specific to trail-related uses: i. The floor area of each tenant space is limited to 2,500 square feet. ii. On-site parking shall be provided at the rate of 1 space per 300 square feet. iii. The hours of operation shall be limited to between 7:00 a.m. and 6:00 p.m. EST, 7:00 p.m. EDT. ivii. Any use that includes outdoor seating shall have a trash container available for disposal of goods consumed on the premises. E. Animal Hospitals and Kennels 3. Specific to T5-UC: Animal Hospitals/Kennels are permitted with the following Conditions:. a. Outdoor Activity: Outdoor activity is permitted during daylight hours; animals must be boarded indoors at night. b. Permitted Accessory Uses: Boarding, retail sales, and grooming services are permitted. 4. Specific to T5-DC: Animal Hospitals/Kennels are not permitted. 5. Specific to IC: General retail/service uses are not permitted along Highway 170 west of W.K. Alston Drive. (Ord. No. O-24-1 , 9-26-2017) 3.7: VEHICLE- AND BOAT-RELATED USES 3.7.1 OVERVIEW OF VEHICLE- AND BOAT-RELATED USE CATEGORIES A. Parking, Commercial: 1. Characteristics: Commercial parking facilities provide parking that is not accessory to a specific use. A fee may or may not be charged. A facility that provides both accessory parking for a specific use and regular fee parking for people not connected to the use is also classified as a commercial parking facility. 2. Accessory Uses: Small structures intended to shield parking attendants from the weather are considered an accessory use. 3. Examples: Examples include municipal and other public garage or surface parking, short - and long-term fee parking facilities, private property where the sole use is parking, and mixed parking lots (partially accessory to a specific use and partly for rent to others ). 4. Exceptions: a. Parking facilities that are accessory to a principal use, but that charge the public to park for occasional events nearby, are not considered commercial parking facilities. b. Parking facilities that are accessory to a principal use are not considered commercial parking uses, even if the operator leases the facility to the principal use or charges a fee to the individuals who park in the facility. c. Public transit park-and-ride facilities are classified as Major Utilities. Formatted: Indent: Left: 0.66", First line: 0" Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 19 of 58 d. Dry boat storage is not permitted in Commercial parking lots. It is considered self -service storage, in the Limited Industrial Services category, when it is a primary use. B. Vehicle and Boat Sales and Rental 1. Characteristics: Boat/Vehicle Sales and Service uses provide direct services to motor vehicles and boats. They also may include businesses that service passenger vehicles, light and medium trucks, and other consumer vehicles/boats such as motorcycles and pleasure watercra ft. 2. Accessory Uses: Accessory uses may include offices, sales of parts and vehicle/boat storage. 3. Examples: Examples include sales or leasing of consumer vehicles including passenger vehicles, motorcycles, scooters, golf carts, light and medium trucks and other recreational vehicles, taxi dispatchers, limousine services, and boat dealerships. 4. Exceptions: Refueling facilities for vehicles that belong to a specific use (fleet vehicles) are considered accessory uses if they are located on the site of the principal use. C. Vehicle Service and Repair: 1. Characteristics: Vehicle Service and Repair provides direct services to motor vehicles and boats. They also may include businesses that service passenger vehicles, light and medium trucks, and other consumer vehicles/boats such as motorcycles and pleasure watercraft. 2. Accessory Uses: Accessory uses include offices, sales of parts and vehicle/boat storage. 3. Examples: Examples include quick lubrication services, tire services, and similar facilities with one-hour service, full-service, vehicle repair shops, transmission or muffler shops, towing services, auto body shops, alignment shops auto upholstery shops, auto deta iling, and tire sales and mounting. D. Drive-Thru Facilities: 1. Characteristics: A primary or accessory facility where goods or services may be obtained by motorists without leaving their vehicles. 2. Accessory Uses: Drive-thrus may be accessory uses attached to the examples listed below. 3. Examples: Examples include drive-thru bank teller windows, dry cleaners, fast -food restaurants, coffee shops, photo stores, pharmacies, etc. The category does not include freestanding ATMs, gas station fuel pumps, or other vehicle services, which are separately def ined. E. Passenger Terminals: 1. Characteristics: Aviation and surface passenger terminals include facilities for the landing and takeoff of airplanes and helicopters, including loading and unloading areas. Aviation facilities may be improved or unimproved. Aviation and surface passenger terminals also i nclude passenger terminals for bus service. 2. Accessory Uses: Accessory uses include freight handling areas, concessions, offices, parking, and maintenance and fueling facilities. 3. Examples: Examples include airports, bus passenger terminals, and helicopter landing facilities. 4. Exceptions: a. Bus passenger stations for local service such as mass transit stops and park -and-ride facilities are classified as Basic Utilities. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 20 of 58 b. Private helicopter landing facilities that are accessory to another use may be considered accessory uses, subject to all the regulations and approval criteria for helicopter landing facilities. F. Water- and Marine-Oriented Facilities: 1. Characteristics: These are facilities for embarking on and disembarking from boats, ferries and water taxis. 2. Accessory Uses: Accessory uses include boat fueling, pump -out facilities, docks, boat house walkways, water- or marine- oriented retail, parking areas, dry boat storage facilities, boat servicing areas, offices, watercraft rentals, and ticket sales. 3. Examples: Examples include marinas, docking facilities, boat ramps, and facilities for tour boats. 4. Exceptions: When watercraft sales and rentals are the primary use of a parcel, the use is classified as Vehicle and Boat Sales and Rental. Residential and community docks are classified as Accessory Uses to residential. 3.7.2 ADDITIONAL STANDARDS FOR VEHICLE- AND BOAT-RELATED USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Vehicle and Boat Sales and Rental: 1. General Provisions: a. Parking: No vehicles or boats shall be parked in public rights -of-way. b. Outdoor Display: No vehicles shall be displayed with their hoods open, except in the display building, which shall be an enclosed structure. Balloons, spinners, pennants, banners, and other wind-blown devices are prohibited. c. Orientation and Screening: Service bay doors shall be located perpendicular to the road fronting the site and shall be screened from all other streets and adjacent residential development. d. Setbacks: When vehicular use/storage areas are between 50 -75 feet from the Critical Line, pervious paving shall be required, and the stalls shall not slope towards the Critical Area. e. Outdoor Intercoms: Outdoor amplification of sound (e.g., loudspeakers) shall not be audible beyond the property lines. f. Orientation: The structure shall be street-oriented, with pedestrian entrances from the street. g. Exceptions: When rental of watercrafts are an accessory use to a Water - and Marine- Oriented Facilities, the provisions above do not apply. 2. Specific to T5-UC: Limousine and Taxi Services are only permitted as accessory uses to offices housing the business operation. All vehicles associated with the business shall meet the setback and screening standards for a parking lot. B. Drive-thru Facilities: Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 21 of 58 1. Design Review: Drive-thru facilities include any building with an external window or station for the purpose of providing services to a person in an automobile. All new drive -through facilities shall be subject to the following standards. a. Service Window Location: The drive-thru window shall not be located on the facade of the building facing any Primary Street frontage. In mid -block and alley-accessed locations, the drive-thru service windows must be located in the rear of properties. b. Drive-Thru Lane Location: Drive-thru lanes shall not circulate around any Primary Street frontage. i. Specific to T5-UC: Drive-thru lanes shall not be visible from any Primary Street frontage. Where the lot configuration makes it impossible to screen the drive - thru lane from the primary street with the building, opaque fencing or vegetation may be permitted to fulfil this requirement, provided all other standards of the ordinance are met. c. Stacking: There shall be no minimum or maximum stacking requirements for vehicles; however they must meet the standard in 3.7.2.B.1.b above. d. Menu Board: One outside menu or order board is permitted, with a maximum of 24 square feet in size and a maximum height of 8 feet above grade. C. Fuel Sales/Car Wash: 1. Location: No more than 2 fuel sales facilities are permitted at an intersection of any Major Thoroughfare with another Major Thoroughfare (See Section 7.2.3 C.2 for a definition). No more than 1 fuel sales facility is permitted at the intersection of other streets, where neither is a Major Thoroughfare. 2. Accessory Uses: a. Site Storage and Service Areas: No open storage of any type, including the overnight storage of vehicles, shall occur in conjunction with the operation. Service areas, storage areas, and refuse enclosures shall be oriented away from public view and screened from adjacent sites. b. Vacuums: Vacuum stations and similar equipment are prohibited on the sides of the principle structure abutting a Primary Street frontage or a residential use. c. Vending: ATMs and other vending machines shall be located within the primary retail building. Where this is not possible — e.g. propane tanks — the sales display shall be screened from any right-of-way or public access drive. 3. Design Standards: See Section 4.5.12. D. Vehicle Services and Repair: 1. Buffer: Parking and/or service areas shall be separated from adjoining residential properties by a planting screen, fence, or wall between 6 and 8 feet in height. 2. Noise: No objectionable sound, vibration, heat, glare, or electrical disturbance shall be created that is perceptible beyond the premises. Orientation: The bay doors to the garage shall not be oriented toward the public right-of-way. 3. Placement along Water Frontage: Structures and vehicular use/storage areas shall be set back a minimum of 75 feet from the OCRM Critical Line. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 22 of 58 4. Outdoor Activities Prohibited: All operations and storage of parts shall be within a fully enclosed building. 5. Screening: Any wrecked vehicles stored on the site shall be located within a fully enclosed building or shall be stored behind the front building line, and shall be completely screened (100% opacity) from the street and adjoining properties using natural buffers, fe ncing, buildings, or a combination thereof. Chain link fencing shall not be permitted as a screening material if the fence will be visible from any right-of-way or parking area. a. Specific to T5-UC: Any Wrecked Vehicles stored on-site during nonbusiness hours shall be contained in a fully enclosed building. 6. Specific to T4-N: This use is limited to facilities that provide one -hour service, where customers typically wait for the vehicle and cars are not stored overnight on -site. 7. Specific to T4-NA: a. This use is permitted within existing buildings only. b. Rear setback is increased to 25 feet when adjacent to a T3 zoning district. 8. Specific to T5-UC: This use is not permitted in the Historic District. E. Parking, Commercial Surface: When commercial surface parking lots are located along a Retail Frontage Overlay zone in T4-N district, or along a Primary Street — as designated in the Street Hierarchy Diagram in Appendix C.2 — in any T5 districts, they shall be screened from the street by a liner building. F. Passenger Terminal: Passenger terminals are limited to bus terminals. 3.8: INDUSTRIAL USE CATEGORIES 3.8.1 OVERVIEW OF INDUSTRIAL USE CATEGORIES A. Aviation Service: 1. Characteristics: Aviation service businesses engage in storage, repair, or servicing of airplanes, helicopters, and related aviation equipment, charter aviation services, flying -related education, and warehousing related to air shipping. 2. Accessory Uses: Accessory uses include offices, parking, warehousing and storage. 3. Examples: Examples include private airports, fixed base operators, flying schools, and air shipment warehouses. 4. Exceptions: a. Car rental agencies associated with commercial air travel are classified as Passenger Terminals. b. Warehousing not associated with air shipping is classified as Warehousing and Freight Movement. B. Light Industrial Service: 1. Characteristics: Light Industrial Service businesses are engaged in the storage, repair or servicing of industrial, business, or consumer machinery, equipment, and products or by -products. Businesses that service consumer goods do so mainly by providing centralized servic es for Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 23 of 58 separate retail outlets. Contractors and building maintenance services and similar uses perform services off-site. Except for self-service storage facilities, few customers, especially the general public, come to the site. 2. Accessory Uses: Accessory activities may include offices, parking, retail, living quarters for a resident manager, rental of trucks or equipment, and outside storage of boats and campers. 3. Examples: Examples include welding shops, machine shops, tool repair shops, electric motor repair shops, shops providing repair of scientific or professional instruments, building, heating, plumbing or electrical contractors, newspaper publishing plants, printing a nd lithography services, exterminators, janitorial and building maintenance services, fuel oil distributors, research, testing and development laboratories, laundry, dry cleaning and carpet cleaning plants, photo-finishing laboratories, self-service storage (syn. mini-warehouses) buildings, and dry boat storage. 4. Exceptions: a. Contractors and others who perform services off -site are included in the Office category, if major equipment and materials are not stored on -site and fabrication or similar work is not carried on at the site. b. Storage areas are designed to allow private access by the tenant for storing or removing personal property. A transfer and storage business where there are no individual storage areas, or where employees are the primary movers of the goods to be stored or transferred, is considered Manufacturing and Production Services. c. Storage bays shall not be used to manufacture, fabricate, or process goods, to service or repair vehicles, small engines or electrical equipment, or to conduct similar repair activities, garage sales or retail sales of any kind, or any other commercial or industrial activity on the site. They shall not be considered premises for the purpose of assigning a legal address. C. Manufacturing and Production Services: 1. Characteristics: Manufacturing and production services businesses are involved in the manufacturing, processing, fabrication, packaging, assembly, warehousing and freight movement, and wholesale sales of goods. Natural, man -made, raw, secondary or partially completed materials may be used. Products may be finished or semi -finished and are generally made for the wholesale market, for transfer to other plants, or to order for Businesses or consumers. Goods are generally not displayed or sold on -site, but if so, they are a subordinate part of sales. Warehouse and freight movement may store and move goods made on site or for other businesses. Wholesale sales businesses are primarily involved in the sale, lease, or rental of products intended for industrial, institutional or commercial business use. While a limited a mount of customers may visit these facilities to view production, make will -call pick-ups or purchase directly from producers, relatively few customers come to the manufacturing and production services site. 2. Accessory Uses: Accessory activities may include offices, cafeterias, parking, retail, restaurants, employee recreational facilities, warehouses, storage yards, repair facilities, truck fleets and associated parking and maintenance areas, repackaging of goods, and careta ker's quarters. 3. Examples: Examples include manufacturing, processing, assembly and storage operations, processing of food and related products including seafood, woodworking, including cabinet makers, production of chemical, rubber, leather, clay, bone, plastic, stone or glass mat erials or products, movie production facilities, concrete batching and asphalt mixing, production or fabrication of metals or metal products including enameling and galvanizing, manufacture or assembly of equipment and instruments, including musical instru ments, appliances, precision Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 24 of 58 items, and other electrical items, production of artwork and toys, sign -making, separate warehouses used by retail stores, such as for storage of materials and equipment, truck terminals, furniture and appliance storage, household moving and general freigh t storage, cold storage plants, including frozen food lockers, parcel services, stockpiling gravel or other aggregate materials, sale or rental of merchandise, machinery, equipment, heavy trucks, building materials, special trade tools, welding supplies, m achine parts, electrical supplies, janitorial supplies, restaurant equipment, and store fixtures, mail order houses, and wholesalers of food, clothing, auto parts and building hardware. 4. Exceptions: a. Business[es] that sell or [manufacture] goods to be sold primarily on -site and to the general public, or on a membership basis, are classified as Retail Sales and Service. b. Manufacturing, production, transfer, or storage of solid or liquid wastes, or goods derived from composting organic material is classified as Waste Related Service. c. Mini-warehouses are classified as self-service storage and is included in the Light Industrial Services use category. D. Waste-Related Service: 1. Characteristics: Waste-Related Services are characterized by uses that receive solid or liquid wastes from others for disposal on the site or for transfer to another location, uses that collect sanitary wastes, or uses that manufacture or produce goods or energy from the composting of organic material. 2. Accessory Uses: Accessory uses may include recycling of materials, offices, and repackaging and transshipment of by-products. 3. Examples: Examples include waste transfer or composting and recycling centers. 4. Exceptions: Disposal of dirt, concrete, asphalt, and similar non -decomposable materials is considered "fill." 3.8.2 ADDITIONAL STANDARDS FOR INDUSTRIAL USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Light Industrial Services: 1. Specific to T4-NA: Rear setback is increased to 25 feet minimum when adjacent to a T3 zoning district. 2. Specific to Self-Service Storage: a. Screening: Self-service storage must be screened from public rights -of-way with fencing (per 3.6.2.D.3.F) and/or vegetation, or be located behind another building that would provide appropriate screening. Where fencing and/or vegetation is used, it must meet the requirements for parking lot screening, as set forth in 5.7.8.A. An office component of the building may be used to screen the storage bays from the right -of-way. b. Specific to T4-NA: This use is permitted in existing buildings only. c. Specific to T5-UC and RMX: Such use shall be setback a minimum of 300 feet from the public right-of-way, with the following exceptions: Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 25 of 58 i. Multi-Story: Multi-story structures, with two or more habitable floors, may comply with the standard setbacks if the ground floor contains an office and/or retail component and meets all of the design standards in Section 4.6. ii. Liner Building: If a Liner Building exists between the storage units and the right - of-way, these uses may be located less than 300 [feet] from the public right -of- way. See Section 4.5.9 for more requirements and standards for Liner Buildings. d. Building Appearance: i. Garage doors serving individual storage units shall be perpendicular to a public or private street, so as to not be visible from adjacent streets. ii. Perimeter or exterior walls visible from a public street or detached residential dwelling shall not include metal as a primary material. e. Fencing: i. Fences shall be between 6 and 8 feet tall. ii. Wooden entry gates without sufficient structural support are prohibited. 3. Operation: a. No more than one security or caretaker quarters may be developed on the site. b. Except for RVs, including boats, all property stored on the site shall be contained entirely within enclosed buildings. B. Manufacturing and Production Services: 1. Specific to T4-NA: Rear setback is increased to 25 feet minimum when adjacent to a T3 zoning district. 2. Access and Circulation: Businesses that primarily provide wholesaling and distribution services use shall have direct access onto an arterial or major collector road. 3. Specific to RMX, Separation: The use shall be located at least 500 feet from any T3 or T4 zoning district (or equivalent within the County), or any IC district parcel that contains residential dwelling units. 4. The operation of the facility shall not become a nuisance to surrounding property owners. 3.9: COMMUNICATION AND INFRASTRUCTURE USES 3.9.1 OVERVIEW OF COMMUNICATION AND INFRASTRUCTURE USE CATEGORIES A. Telecommunications Facilities: 1. Characteristics: Telecommunications facilities include all devices, equipment, machinery, structures, or supporting elements necessary to produce non -ionizing electromagnetic radiation within the range of frequencies from 100 KHz to 300 GHz and operating as a discrete unit to produce a signal or message. Facilities may be self -supporting, guyed, or mounted on poles, other structures, light posts, power poles, or buildings. Facilities also include intertie and interconnection translators, connections from over-the-air to cable, fiber optic, or other landline transmission system. 2. Accessory Uses: Accessory use include transmitter facility buildings. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 26 of 58 3. Examples: Examples include broadcast towers, communication towers and point -to-point microwave towers. 4. Exceptions: a. Receive-only antennas are not included in this category. b. Radio and television studios are classified in the Office category. c. Radio and television broadcast facilities that are public safety facilities are classified as Basic Utilities. B. Infrastructure/Utilities (Major and Minor): 1. Characteristics: Major utilities are infrastructure services providing City -wide service. Minor utilities are infrastructure services that need to be located in or near the area where the service is provided. 2. Accessory Uses: Accessory uses include public utility parking and control, monitoring, and data or transmission equipment. Services may be publicly or privately provided. 3. Examples: a. Examples of major utilities include above-ground public utility lines, public utility plants, water towers, waste treatment plants, electrical substations, and telephone exchanges. b. Examples of minor utilities include underground public utility lines, public utility substations, water and sewage pump stations, electrical junction boxes, and block - or neighborhood-scale stormwater management facilities. Minor utility uses generally do not regularly have employees at the site. 4. Exceptions: a. Maintenance yards and buildings are classified as Industrial Services. b. Utility offices are classified as Offices. 3.9.2 ADDITIONAL STANDARDS FOR COMMUNICATION AND INFRASTRUCTURE USES The following additional standards apply to the approval and development of projects where the use is listed in the "Table of Permitted Uses" in Section 3.2 as Conditional (C), Special Exception (SE), or T4 -Neighborhood Artisan (A). In addition, any Building Design standards, as set forth in Article 4, apply as applicable. A. Major Infrastructure/Utility, Specific to T4-NA: This use may be located in existing facilities only. B. Minor Infrastructure/Utility: 1. Location: Above-ground structures shall be located on interior properties, rather than on properties aligned with other lots that have continuous street frontage. Where this is not possible and the structures must be located on a street, they shall not be located o n corners. 2. Screening and Buffer: Structures greater than 3 feet in height that cannot adhere to the scale, volume, spacing, setback, and typology of existing buildings along fronting streets, shall be designed so they do not have an adverse effect on the streetscape. Treatments may inclu de a wall, landscaping, or architectural design solutions as approved by the Administrator. 3. Accessory Uses: No office, commercial operation, storage of vehicles, or equipment shall be allowed on the premises. 4. Signage: No commercial or branding signage is permitted. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 27 of 58 5. Specific to Public Utility Substations: a. Screening: Public utility substations shall be enclosed by a wall or fence at least 6 feet in height above finished grade. Opacity requirements shall meet the standards described in Section 5.7.8 A. b. Location: Public utility substations shall not be located where visible from a primary public right-of-way. They shall be located internally on a property and screened from the right -of- way with buildings. Where this is not possible and the structures must be locat ed on a street, they shall not be located on corners. c. Design: Building design shall comply with the standards of the specific district as outlined in Article 4. d. Buffer: A landscaped strip not less than 5 feet in width shall be planted and maintained around the facility. e. Accessory Uses: No office, commercial operations, or storage of vehicles or equipment shall be allowed on the premises. C. Waste Related Services, Buffer: An additional 10 feet of forested buffer or an 8 foot wall, landscaped with 1 overstory tree per 50 feet, is required around the entire property. If the adjacent property is zoned T3 or T4-HN, both the wall and an additional 25 feet of forested buffer sha ll be included. D. Wireless Communications Facility: 1. Collocation: a. Due Diligence: All applications where wireless communication facilities are not being provided through collocation shall include a collocation study that demonstrates there is not a suitable collocation site that can serve the needs of the user. Placement on existing towers, water towers or other tall structures shall be fully considered prior to making an application for a new tower. b. Proximity: When a new tower is proposed within two miles of an existing tower, the applicant will be expected to prove that there is no technologically and structurally suitable space available within the search ring. The applicant shall submit satisfactory written evidence such as correspondence, agreements, contracts, etc., that alternative towers are not available for use. The proposed tower, if approved, shall be either camouflaged or stealth in design. c. Speculation Towers: Speculation towers are prohibited. d. Quantity of Locations: i. All structures less than 125 feet in height shall make provision for at least two locations. ii. Towers between 125 feet and 200 feet in height shall have at least four locations. e. Expansion: The design of ground structures for new towers shall be such that modular expansion to accommodate collocation is feasible. 2. Freestanding Towers: The following conditions shall be met before a freestanding telecommunication tower is approved: a. Maximum Height: i. 125 feet for towers with provisions for two or three locations. Created: 2023-12-08 08:25:07 [EST] (Supp. No. 1) Page 28 of 58 ii. 180 feet for towers for provisions for four or more locations. iii. In the LI zone, heights over 180 feet will be permitted by Special Exception by the Zoning Board of Appeals, subject to Section 9.13. b. Setbacks Requirements: i. Collapse Zone (syn. Fall Zone): A collapse zone shall be designed so that tower collapse will occur only within the property owned or leased by the tower company, or controlled by an easement held by the tower company. ii. Residential Setback: The tow

Text truncated. Open the original for the full document.

Source: City of Beaufort website. First collected Oct 24, 2026.