RecordWell Data

Board of Architectural Design and Historic Review — Agenda Packet

City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Aug 14, 2025 · Agenda packets

Open the original document More from City of Spartanburg

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

The City of Spartanburg Board of Architectural Design & Historic Review City of Spartanburg | Board of Architectural Design & Historic Review 1 AGENDA August 14, 2025, at 5:30 P.M. Spartanburg County Council Chambers 366 N. Church Street – Spartanburg, SC 29303 (Please Note: Items as they appear on the Docket may or may not be considered in the order as they are presented. The Chairman will announce any changes after the roll call) I. Call To Order. II. Roll Call. III. Freedom of Information Act Compliance – Public notification of the City of Spartanburg’s Board of Architectural Design & Historic Review meeting has been published, posted, and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg’s Zoning Ordinance. IV. Rules and Procedures for Meeting Conduct. V. Approval of Agenda. VI. Disposition of Minutes from the April 10, 2025, Meeting. VII. Old Business: None. VIII. New Business: 1. COA: 25-004-00023: Certificate of Appropriateness for Major Works – 232 Hydrick Street (TMS # 7-12-14-166.00) in the Hampton Heights. The applicant is seeking approval for new construction. The property is located in the R-8 (General Residential) zoning district. Owner: City of Spartanburg | Applicant: James White Enterprises, LLC. 2. COA: 25-004-00049: Certificate of Appropriateness for Major Works – 511 S Irwin Avenue (TMS # 7-16-02-134.00) in the Hampton Heights. The applicant is seeking approval for a detached garage, and window replacement. The property is located in the R-8 (General Residential) zoning district. Owner: Sarah Brodie | Contractor: Will Hammond. IX. Staff Updates: o Property at 607 S. Irwin Avenue – Mediation update. o ACOG Continued Education and Orientation for newly appointed board members. o Welcoming new Planning staff: Ben Jones, Senior Planner, and Dominick Calace, Planner I. X. Adjournment. For more information, please contact the City of Spartanburg Planning Department at planning@cityofspartanburg.org or call (864) 596-2068. 1 of 77 HARB – Meeting Minutes – 2025-04-10 Page 1 of 3 Meeting Minutes of the Board of Architectural Design and Historic Review Thursday, April 10, 2025, at 5:30 PM Spartanburg County Council Chambers The City of Spartanburg Board of Architectural Design and Historic Review (HARB ) met in County Council Chambers on Thursday, April 10, 2025, at 5:30 PM with the following members in attendance: Bill Michels, Sylvelie Franke, Dave Williams, Rod McCants, Kenneth Brown, and Brandon Gaffney Representing the Planning Department - Fredalyn Frasier, Planning Director, Oksana Holbrooks, Sr. Administrative Assistant, and Nan Zhou, Planner II. Roll Call: Mr. Michels: Bill Michels Mr. Williams: Dave Williams Mr. Brown: Kenneth Brown Mr. McCants: Rod McCants Mr. Gaffney: Brandon Gaffney Ms. Franke: Sylvelie Franke Mr. Michels: Freedom of Information Act Compliance – Public notification of the City of Spartanburg Board of Architectural Design and Historic Review (HARB ) this meeting has been published, posted and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg Zoning Ordinance. Approval of Agenda: A motion was made by Mr. Brown, seconded by Ms. Franke to approve the agenda. The motion was approved with a vote of 6-0. Approval of Meeting Minutes from March 13, 2025. A motion was made by Mr. Williams, seconded by Mr. Gaffney to approve the meeting minutes as amended. The motion was approved with a vote of 6-0. Old Business: None. New Business: COA: 25-004-00026: Certificate of Appropriateness for Major Works – 395 Gentry Street (TMS # 7-16-02-142.00) in the Beaumont Mill Village . The applicant is seeking approval to replace front and side windows, from and side exterior walls with hardie fiber cement lap siding, and re-shingle with asphalt shingles. The property is located in the R-6 (General Residential) zoning district. Owner: James and Maria Meet You in Paradise Falls LLC, Contractor: Chad Tessinger, Tesco Construction. Project Description and History The project site is located on an approximately 6,670 square foot lot in the Beaumont Mill Village Historic District on the north side of Gentry Street. The site currently consists of a one-story single- family residence constructed in 1941. This residential structure is a wood-framed bungalow with a brick foundation, front porch with interior brick chimney, and has a gable roof with composite shingle. • The Beaumont Mill Village Historic Design Guidelines list this structure as a 2 of 77 HARB – Meeting Minutes – 2025-04-10 Page 2 of 3 House Type Fifteen – End Gable with Gable Front Porch. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Beaumont Village Design Guidelines for the City of Spartanburg Historic District Preservation Principles and Approaches. The purpose of the Guidelines is to provide property owners guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. The project is also subject to Section 510 of the City’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the Standards listed in the Ordinance. The project site has a zoning designation of R-6, General Residential District, which allows for single family dwelling units. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing Certificate of Appropriateness. Specifically, Section 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation, and the five criteria listed in the findings. Applicant Statement • The Applicant proposes to replace front and side windows with aluminum clad wood windows and replace front and side siding with James Hardie Fiber Cement Lap siding. Findings Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design Windows. Design Guidelines for Beaumont Mill Village state that “…… windows are another significant character defining feature of any home. Wood windows were constructed so that individual pieces could be taken apart and repaired as needed. Therefore, many original windows could be repaired for much less than replacing a window. If it’s determined that the windows are in such deteriorated condition that they must be replaced, the new windows should be compatible in terms of material, size of window, shape and size of sash, window pane size and configuration, muntin and mullion profile shape, and location of meeting rial. In Beaumont Mill Village, wood and aluminum clad wood windows are the most appropriate replacement materials” Design Guidelines for Beaumont Mill Village state that “……most of the homes in Beaumont were originally wood siding. If this material still exists on the home, it should be retained. Many homes in the area have aluminum or vinyl siding added to them. Some homes have asbestos siding which is original to their design and some asbestos siding was added to earlier homes in the 1950s. details of the original home have been lost due to the additions of these materials. Artificial siding can trap moisture underneath and decay the original wood. Therefore, homes that do not have these materials on them should not consider artificial materials as a replacement to the damaged wood. Repair is the only option. Wood siding should be kept painted and aluminum siding should be kept clean. Should it become necessary to replace the siding, then the new boards should match the existing boards in width and any characteristics, such as corner boards. If more than 50% of non-original siding will be replaced, then the type of replacement siding must match the historic style siding. Appropriate new material should be wood or Cement Fiberboard.” • The proposed repairs are consistent with the Beaumont Mill Village design intent. 1) Replacement of the front and side wood windows with white aluminum clad wood windows (31.5” by 55”) in existing opening, double hung, and six by six configuration. 2) Replacement of the current damaged asbestos siding with James Hardie Fiber Cement Board Lap Siding that is recommended by the Beaumont Mill Village Design Guideline. b. The scale of the buildings 3 of 77 HARB – Meeting Minutes – 2025-04-10 Page 3 of 3 • Replacing windows and siding will not impact the scale of the building. c. The texture and materials The proposed materials are consistent with the Beaumont Mill Village material guidelines. 1) The current front and side windows are wood. The new proposed windows would be white aluminum clad wood windows, double hung, and six by six configuration. 2) The current front and side siding material is asbestos siding. The new proposed siding is James Hardie Fiber Cement Board Lap Siding. d. The relationship of such elements to similar features of structures in the immediate surroundings – 1) Properties in the immediate surroundings of the project site appear to have a combination of wood and vinyl windows. 2) Properties in the immediate surroundings of the project site appear to have a combination of wood and vinyl siding on the house. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – 1) Repairing the damaged or deteriorated wood windows is recommended. If the windows are beyond repair, the replacement of the windows’ material, style, and size would be harmonious with the Beaumont Mill Historic District. 2) Based on the Design Guidelines for the Beaumont Mill Village, the new siding replacement material matches the historic style siding and meets the design guideline recommendation. Applicant: James and Maria Miles, Meet You in Paradise, Owner. Public Speakers: None Discussion: The Board discussed the historical context and architectural character of the property and surrounding area. It was noted that the windows, siding, and roof are currently in a state of significant disrepair. The applicant presented a proposal to replace various window types with historically appropriate alternatives that meet historic guidelines. The Board expressed general support for the proposed replacements, emphasizing the importance of maintaining historic character while improving structural integrity. The use of compatible siding and wood materials was also discussed as acceptable in preserving the overall appearance and historic value of the structure. A motion was made by Mr. Michels and Mr. Brown, seconded by Mr. Gaffney, to approve the replacement of windows as requested with a 7/8ths inch muntin on the exterior with on the inside 6 over 6s, removal of asbestos siding to be repaired with wood siding at the front, left and right side, with wood from rear or new wood cut to fit profile with the rear of the house could be Hardie board if necessary. The motion passed with a vote of 6–0. Staff Announcements: Continue Education certifications. The meeting was adjourned at 6:19 PM. ______________________________ Bill Michels , Chairman 4 of 77 Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org August 7, 2025 TO: The Board of Architectural Design and Historic Review RE: Certificate of Appropriateness for Major Works Address: 232 Hydrick Street (TMS: 7-12-14-166.00) Historic District: Hampton Heights Historic District Zoning: R-8 SFD (Single Family District) Owner: City of Spartanburg Applicant: Oak and Ave Property Group Request: The applicant is seeking approval to construct a new 2,617 square foot home on a property in the R-8 SFD zoning district. Project Description and History The project site is located on an approximately 7,500 square foot lot in the Hampton Heights Historic District on the west side of Hydrick Street near the intersection with West Henry Street. The site is currently vacant. The applicant proposes to build a 2,617 square foot single-family dwelling unit on the lot. The proposed residential structure is a one-and-a-half story Craftsman style home measuring 35 feet in width and 63 feet 2 inches in length, with a peak ridge height of 30 feet 8 inches. The house will be constructed on a brick foundation with a crawl space. A full -width front porch measuring 9 feet in depth will span the entire facade . The porch decking will consist of TimberTech grooved composite deck board and will be supported by brick foundations with painted wood columns . A matte black aluminum porch railing will enclose the porch, and the brick pier foundations will feature black vinyl lattice. The applicant is proposing to clad the house in Hardie Plank lap siding. The dormer will have vertical board and batten siding. The two front porch windows will be black wood, one over one double pane windows. The dormer and side windows will be black wood framed six over six double pane windows. The front door is proposed to be a craftsman style mahogany stained wood door. The roof will be comprised of architectural shingles. A split strip driveway is proposed along the side of the home with a concrete parking pad located in the rear yard. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Hampton Heights Design Guidelines for the City of Spartanburg Historic Di strict Preservation Principles and Approaches . The purpose of the guidelines is to provide property owners with guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. 5 of 77 The project is also subject to Section 510 of the City’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the Standards listed in the Ordinance. The project site has a zoning designation of R -8 SFD, Single Family District, which allows for single family dwelling units. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing Certificate of Appropriateness. Specifically, Section 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation, and the five criteria listed in the findings. Normally, when a new house is proposed in most other areas of the city, only a building permit is required. However, due to the location, th e proposed house is subject to Section 6.0, New Construction Guidelines, of the Historic Districts Design Manual. 6.2 Recognizing the Prevailing Character of Existing Development • Identify and respect the prevailing character of adjacent historic buildings and surrounding developments. The surrounding homes near the proposed development are predominantly bungalows in character. The proposed residence incorporates defining features of the Craftsman Bungalow style, including prominent columns and a full -width front porch. The scale and des ign of the front porch are consistent with those found on other Craftsman-style homes within the district. 6.2.1 Building Setback and Orientation: • The orientation of a new building and its site placement shall appear to be consistent with dominant patterns within the area of influence, if such patterns are apparent. The applicant's submission of the site plan indicates that the structure will be located ~10 feet from the north side setback and 18 feet 4 inches from the south side setback. The submitted materials do not clearly indicate the proposed front setback; however, it appears that the structure is set farther back than the adjacent properties. To maintain the established streetscape and neighborhood character, the front setback should align more closely with that of neighboring homes and not exceed the prevailing setback pattern in the area. 6.2.2 Directional Emphasis: • A new building’s directional emphasis shall be consistent with dominant patterns of directional emphasis within the area of influence, if such patterns are present. The structure will exhibit horizontal directional emphasis and face Hydrick Street, consistent with other structures on the street. 6.2.3 Shape: • Roof Pitch: The roof pitch of a new building shall be consistent with those of existing buildings within the area of influence, if dominant patterns are apparent. The roof pitch of the proposed house will be 4:12 at the front of the house and transition to 8:12 near the center of the dormer. This roof pitch is consistent with Craftsman Bungalow style homes in the district. • Porch Form: The shape and size of a new porch shall be consistent with those of existing historic buildings within the area of influence, if dominant patterns are apparent. The front porch extends along the entire length of the home’s facade, 33 feet and extends 9 feet out from the home. This porch size is consistent with other Craftsman style front porches in the district. The 6 of 77 structure has four brick foundation columns with painted wood columns. This style is consistent with other Craftsman homes in the district. • Building Elements: The principal elements and shapes used on the front façade of a new building shall be compatible with those of existing buildings in the area of influence, if dominant patterns are apparent. The applicant is proposing a craftsman style home with symmetrical features. The door will be located in the center of the facade flanked by one-over-one double-pane windows on either side. The dormer will be located in the center of the structure with two six over six windows. The north side of the home will have a 3 foot by 14 foot bump-out addition on the first floor. The principal elements and shapes are consistent with adjacent structures and other Craftsman style homes in the historic district. 6.2.4: Massing: • The massing of a new building shall be consistent with dominant massing patterns of existing buildings in the area of influence, if such patterns are apparent. The proposed structure is a 1.5 story home. The ridge height of the proposed building is 30 feet 8 inches. The design also includes a dormer in the front of the house that will extend from the peak of the roof to the front porch. Adjacent homes on the street range in height from 1 to 2 stories. The scale and form of the structure are appropriate for the surrounding neighborhood. 6.2.5: Proportion: • The proportions of a new building shall be consistent with dominant patterns of existing buildings in the area of influence, if such patterns are apparent. There is no information in the submission that provides the proportion of the structure in relation to other structures. Based on staff observations at the project site, the proportion of the proposed structure is consistent with the design guidelines. 6.2.6 Rhythm: • New construction in a historic area shall respect and not disrupt existing rhythmic patterns in the area of influence, if such patterns are present. There is no information in the submission that provides the rhythm of the structure in relation to other structures. Based on staff observations at the project site, the rhythm of the proposed structure is consistent with the design guidelines. 6.2.7 Scale/Height: • New construction in historic areas shall be consistent with dominant patterns of scale with the area of influence, if such patterns are present. The structure is a 1.5 story home. The structure is 35 feet 10 inches wide, 60 feet 4 inches long, and has a peak ridge height of 30 feet 8 inches. The front porch extends along the entire front facade and will be 9 feet in depth. Adjacent homes on the street range from 1 to 2 stories . The proposed scale and height are consistent with adjacent homes and the design guidelines. The size of the front porch is similar to that of other properties in the surrounding area. Findings Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design 7 of 77 The character of the surrounding homes can be described as bungalows. Although the housing style is not specifically mentioned in the submission, the features are typical of a Craftsman Bungalow with its prominent front porch and columns. The size and design of the front porch are typical of the surrounding properties. The site plan shows a split strip driveway on the south side of the lot leading to a concrete parking pad in the rear yard . The proposed setback is unclear, but it must be consistent with adjacent structures on Hydrick Street. The zoning ordinance requires 30 feet, and a Board of Zoning Appeals (BZA) approval is required for a reduction of this requirement. b. The scale of the buildings The proposed home is 1.5 stories. The structure is 35 feet 10 inches wide, 60 feet 4 inches long , and has a peak ridge height of 30 feet 8 inches. The front porch extends along the entire front facade and will be 9 feet in depth. Adjacent homes on the street range from 1 to 2 stories. The proposed scale and height are consistent with adjacent homes and the design guidelines. The size of the front porch is similar to that of other properties in the surrounding area. c. The texture and materials The proposed house will use Hardie Plank lap siding on most of the structure. The dormer will use board and batten style Hardie Plank siding. The material creates the appearance of wood siding, which is consistent with surrounding homes, but the vertical orientation of the siding on the dormer is not found within this historic district. It is suggested to be changed to a horizontal orientation to match the rest of the home. The visible width of the siding is unclear but should not exceed 5 inches. A sample of the siding should be provided for review by staff. The front porch is proposed with painted wood columns with brick foundations. The porch decking will be TimberTech composite deck boards. This material is not consistent with home in the historic district and is recommended to be changed to 3 -inch tongue and groove wood deck boards. The railing will be matte black aluminum. This type of railing is not consistent with homes in the historic district and is suggested to be changed to a traditional wood railing. The proposal shows black vinyl lattice between the brick posts. This material is not consistent with the design guidelines and should be changed to wood lattice. The home’s foundation will be brick and includes a crawl space. The foundation is consistent with the design guidelines. The roof will have a 4:12 pitch at the front of the home which transitions to an 8:12 pitch near the center. The roof is proposed to be composed of charcoal architectural shingles. The roof material and design are consistent with the design guidelines. A craftsman style mahogany-stained door is proposed for the front of the house. This type and style of door is consistent with the historic design guidelines and other doors in the adjacent properties . The proposal shows one over one black wood windows on the porch. The dormer and side windows are six over six black wood windows. All windows are double pane glass. The drawings do not show any trim around the window perimeter. Traditional window trim and sills should be included in the final designs. d. The relationship of such elements to similar features of structures in the immediate surroundings – The proposed Bungalow is an appropriate design for the site. It will match the prevailing character of the surrounding homes, most of which are some form of Bungalow. The porch is a character defining feature of the Bungalow. There are multiple structures on Hydrick Street with similar styles of front porches. It is not clear how some of the features are consistent with other character defining features in 8 of 77 the neighborhood. No examples of existing features in the neighborhood were provided as examples for this submission. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – The structure will be similar to other homes in the neighborhood, including the front porch, windows, and doors. The siding proposed in the applicant’s site plan appears to be consistent with the building materials of surrounding homes, with the exception of the vertical siding on the dormer . The construction makes use of an otherwise vacant and underutilized lot in the historic district. Staff Recommendation Staff recommends approval of the proposed design contingent upon incorporation of the following revisions to ensure consistency with the Hampton Heights Design Guidelines: 1. Siding: • Vertical board and batten siding on the dormer to be changed to horizontal lap siding to match the rest of the home. • A sample of the Hardie Plank lap siding shall be provided to the Planning Department for review prior to approval. 2. Railings: Aluminum porch railings should be changed to a traditional wood railing. 3. Setback: Site plan adjusted to show a front setback consistent with adjacent homes. 4. Lattice: Vinyl lattice to be replaced with wood lattice to be consistent with historic design guidelines (Section 8.1.7). 5. Window Trim: Revise drawings to show trim around the window perimeter. Traditional window trim and sills should be included. 6. Porch Decking: TimberTech composite de cking should be replaced with 3-inch wood tongue and groove deck boards. Submitted by: Dominick Calace Planner I City of Spartanburg Planning Department Attachments: Conditions of Approval Site Map Zoning Map Site Photos Application and Materials 9 of 77 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY AT: 232 Hydrick Street (TMS: 7-12-14-166.00) - Hampton Heights Historic District Owner: City of Spartanburg Applicant: Oak and Ave Property Group Contractor: James White Enterprises 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All plans for future construction which are not covered by this review shall be submitted to the City Planning Department for review and approval. 3. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 4. This permit shall be exercised within six months of the date of final approval, or it shall become null and void. Extensions may be granted with permission of the Board. 5. A building permit shall be obtained from the Building Department prior to commencement of work. 6. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 10 of 77 Site Map – 232 Hydrick St. 11 of 77 Zoning Map – 232 Hydrick St. 12 of 77 Photo - Project Site (Vacant Lot) 13 of 77 Properties to the Left and Right of Project Site 14 of 77 Properties in the Vicinity 15 of 77 16 of 77 17 of 77 18 of 77 19 of 77 20 of 77 21 of 77 22 of 77 23 of 77 24 of 77 25 of 77 26 of 77 27 of 77 28 of 77 29 of 77 Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org August 7, 2025 TO: The Board of Architectural Design and Historic Review RE: Certificate of Appropriateness for Major Works Address: 511 S Irwin Ave (TMS: 7-16-02-134.00) Historic District: Hampton Heights Historic District Zoning: R-8 SFD (Single Family District) Owner/Applicant: Sarah Brodie Contractor: Will Hammond Request: The applicant is seeking approval to construct a new one-car garage at the end of the driveway. The applicant is also requesting to replace the two side -facing attic windows on the existin g home. Project Description and History The project site is located on an approximately 20,000 square foot lot in the Hampton Heights Historic District on the east side of S Irwin Ave and north of S Hampton Dr. The residential structure was constructed in 1940. It is a one-story home with mid-century minimal traditional architecture. The proposed structure is a one-car garage with a loft. The garage is 24 feet long, 16 feet wide, and has a peak ridge height of 18 feet 7 inches. The garage door that faces the street is proposed as a carriage-style door. The siding is proposed as shingle siding that will match the house. The roof is proposed as metal/tin roofing. The applicant is seeking approval to replace two original windows that are located in the gable ends of the house and are not visible from the public way. The applicant states that the windows have deteriorating frames and sashes that are beyond repair. The windows will be replaced with like -for-like six over six single pane all wood windows. Exterior casings will remain. Photos of both the interior and exterior of the windows are included as well as the specifications for the proposed windows are included in the application. Analysis Zoning Ordinance and Historic Design Manual Consistency The design guidelines are outlined in the Hampton Heights Design Guidelines for the City of Spartanburg Historic Di strict Preservation Principles and Approaches . The purpose of the guidelines is to provide property owners with guidance for the preservation and protection of historic and architecturally valuable districts and sites in the City. The project is also subject to Section 510 of the City’s Zoning Ordinance, Historic Preservation. This section allows the Board to review applications involving historic structures and districts and issue a Certificate of Appropriateness subject to the standards listed in the Ordinance. 30 of 77 The project site has a zoning designation of R -8 SFD, Single Family District. Section 510.6 of the City of Spartanburg Zoning Ordinance list standards for reviewing a Certificate of Appropriateness. Specifically, Section 510.6 (C)(2) states that in reviewing applications for new construction or alteration, the Board shall consider the U.S. Secretary of the Interior’s Standards for Rehabilitation and the five criteria listed in the findings. Hampton Heights Design Guidelines Findings - Windows Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design Section 8.1.4 Windows of the Hampton Heights design guidelines states, “...Windows are very important in creating rhythm on a house and also play a role in the directional emphasis and scale of building. Existing windows, including window sash, glass, lintels, sills, frames, molding, shutter, and all hardware shall be retained and repaired through routine maintenance whenever possible. When de teriorated elements must be replaced, new materials shall be compatible with original materials in terms of material, design, and hardware. If it is necessary to replace an entire window, the replacement shall be sized to the original opening and shall duplicate all proportions and configurations of the original window. The residences of Hampton Heights display a variety of window types and materials. Sach, casement, pivot, and decorative fixed windows are all found in the district. Wood sashes are most typical, but metal, as in the case of casement, is also present. Single, grouped, tripartite, and even banded are all arrangements found in the district. The glazing patterns, materials, and arrangements of windows play a key role in defining the styles of Hampton Heights architecture and contribute to the overall appearance of the district.” • The proposed replacement windows are wood single pane six over six windows. This is a like-for- like replacement that will match the existing windows. b. The scale of the buildings • Replacing windows will not affect the scale of the building. c. The texture and materials • The proposed window s are like-for-like wood single pane six over six windows . The texture and materials are consistent with the design guidelines. d. The relationship of such elements to similar features of structures in the immediate surroundings – • The properties in the immediate surroundings appear to have wood windows. As these windows are a like-for-like replacement, they will be consistent with features of surrounding historic homes. e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – • Replacing the two side -facing attic windows with like -for-like wood single pane six -over-six windows would be historically appropriate and harmonious with the historic district. 31 of 77 Findings - Garage Certificate of Appropriateness, Section 510.6 (C) a. The character and appropriateness of the design Section 10.2.6 Accessory Buildings of the Hampton Heights Design Guidelines state s, “...A number of historic garages and garage apartments remain intact in the Hampton Heights neighborhood. These accessory buildings are generally located to the rear of the main house and are important site elements of the overall historic property. They often reflect the architectural style and character of the main house in their materials and design. Many of these accessory buildings have been lost over the years. Guideline: New accessory buildings, such as garages or storage houses, shall be located in rear yard space s and visually buffered from adjacent property owners and the public right -of-way. Accessory buildings that complement and/or duplicate the architecture of the adjacent residence do not require the same amount of buffering but may remain more visible within the local district.” • The proposed structure is located to the rear of the main house. The siding will match the material of the main house. It is proposed as painted shingle siding. The architectural style of the exterior features is not compatible with the house. Specifically, the coverings over the garage doors and side doors resemble the arts & crafts style, but the house is from a later period (minimal traditional style). It is recommended that the applicant removes the coverings over the garage door and side door or replaces them with awnings that are more appropriate for the period style of the primary structure. The proposed structure is partially buffered from view by the primary structure as well as the landscaping along the property line . With the changes based on staff recommendations, the character and appropriateness of the design will be consistent with the historic district. b. The scale of the buildings • The proposed garage will be 24 feet long, 16 feet wide, and has a peak ridge height of 18 foot7 inches. The structure also includes a coverage porch facing the yard that extends 6 feet over the side door. The height of the porch is 8 feet. The roof pitch is 11:12, which matches the primary structure. The scale of the garage is consistent with other garages in the historic district. c. The texture and materials • The proposed garage will use painted shingle siding that matches the existing house. Staff recommends providing a sample of the siding for staff review. The roof is proposed as a metal/tin roof. This roof does not match the arch itectural shingles of the existing home. Staff recommends changing the roof material to architectural shingles that match the primary home. Carriage style garage doors are proposed to face the street . There is one window facing the street over the garage door. This is proposed as a double hung four over four window. Renderings of the proposed garage are included in t he application. With the changes based on staff recommendations, the texture and materials will be consistent with the historic district. d. The relationship of such elements to similar features of structures in the immediate surroundings – • The proposed garage design is consistent with similar garages in the surrounding area. The siding material is consistent with the primary structure. Homes in the surrounding areas have garages with similar features to the proposal. 32 of 77 e. If the property is in a Historic District, the extent to which the alteration or construction would be harmonious with the Historic District – • The structure will be similar to other accessory structures in the neighborhood. With minor changes based on the staff recommendations, the garage’s features will duplicate the architectural style of the primary structure. The overall features are harmonious with the historic district, and much of the proposed garage is also buffered by the primary structure and adjacent landscaping. Staff Recommendation Staff recommends approval of the proposed windows. The windows will be replaced with like-for-like wood single-pane windows. This aligns with the goal of the design guidelines to preserve the character of the historic residential buildings. Staff has also taken into account that the windows are not visible from the public right of way. Staff recommends approval of the proposed garage contingent upon incorporation of the following revisions to ensure consistency with the Hampton Heights Design Guidelines. Recommendation: Approval with Conditions 1. Applicant to provide samples/submittals of the siding, windows, garage door, and roof materials for staff review 2. Applicant to revise plans to incorporate architectural shingles instead of the proposed metal/tin roof. 3. Applicant to revise coverings over garage door and side door to align with minimal traditional architecture style of primary structure. Zoning Conditions: Area above garage is not to be used as a dwelling unit or office for a home occupation. Submitted by: Dominick Calace Planner I City of Spartanburg Planning Department Attachments: Conditions of Approval Site Map Zoning Map Site Photos Application and Materials 33 of 77 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY AT: 511 S Irwin Ave (TMS: 7-16-02-134.00) - Hampton Heights Historic District Owner/Applicant: Sarah Brodie Contractor: Will Hammond 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All plans for future construction which are not covered by this review shall be submitted to the City Planning Department for review and approval. 3. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 4. This permit shall be exercised within six months of the date of final approval, or it shall become null and void. Extensions may be granted with the permission of the Board. 5. A building permit shall be obtained from the Building Department prior to commencement of work. 6. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 34 of 77 Site Map – 511 S. Irwin Ave 35 of 77 Zoning Map – 511 S. Irwin Ave 36 of 77 Photo - Front, Left, and Right of the Project Site 37 of 77 Properties to the Left and Right of Project Site 38 of 77 Properties in the Vicinity 39 of 77 40 of 77 41 of 77 42 of 77 43 of 77 44 of 77 45 of 77 46 of 77 47 of 77 48 of 77 49 of 77 50 of 77 51 of 77 52 of 77 53 of 77 54 of 77 55 of 77 56 of 77 57 of 77 58 of 77 59 of 77 60 of 77 61 of 77 62 of 77 63 of 77 64 of 77 65 of 77 66 of 77 67 of 77 68 of 77 69 of 77 70 of 77 71 of 77 72 of 77 73 of 77 74 of 77 75 of 77 76 of 77 77 of 77

Source: City of Spartanburg website. First collected Oct 24, 2026.