DRB – Meeting Minutes – 2025-04-01
Page 1 of 7
Meeting Minutes of the Design Review Board (DRB)
Tuesday, April 1, 2025, at 5:30 PM
Dr. TK Gregg Recreation Center
The Design Review Board (DRB) on Tuesday, April 1, 2025, at 5:30pm. The following Board
Members were in attendance: Lauren Rogers, Jean Crowther, Tori Babcock, Alexander Newman,
and Lukas Hauser. Representing the City of Spartanburg’s Planning Department was Fredalyn
Frasier, Planning Director, Nan Zhou, Planner II, and Oksana Holbrooks, Sr. Administrative
Assistant.
Roll Call:
Mr. Newman: Alexander Newman
Ms. Crowther: Jean Crowther
Mr. Hauser: Lukas Hauser
Ms. Babcock: Tori Babcock
Ms. Rogers: Lauren Rogers (Late arrival).
Ms. Babcock: With the Freedom of Information Act Compliance, public notification of the Design
Review Board meeting has been published, posted and mailed in compliance with the Freedom of
Information Act and the requirements of the City of Spartanburg Zoning Ordinance.
Amend the Agenda:
On a motion by Mr. Newman to approve and seconded by Mr. Hauser the case has been moved
to the top of the agenda list by a vote of 5 to 0.
Approval of Meeting Minutes for March 4, 2025.
On a motion by Mr. Newman to approve and seconded by Mr. Hauser, the amended minutes
were approved by a vote of 5 to 0.
Old Business:
DRB-24-020-00020 – The Design Review Board (DRB) has received a request for Full and Final
Approval for the proposed Building, Magnolia Block Apartments located at 187 W Broad Street
(Tax Map Sheet: 7-12-20-048.00, 7-12-20-049.02, 7-12-20-049.00, and 7-12-20-050.00) with a
zoning designation of DT-5 Zone (Downtown Urban District) Owner: Haven at West Broad,
LLC. /Applicant: Chris Van Kley, Dwell Design Studio.
GENERAL PROJECT OVERVIEW
The proposed redevelopment includes a 5 story apartment building and shared parking structure, with
primary frontage along West Broad Street and bound by Daniel Morgan Avenue to the west and
Spring Street to the east. It is a part of a larger development that includes 189 West Main Street to the
north of Broad Street. The project was presented for Full and Final Approval on March 4, 2025 and
the Board voted to continue the case to its April 1, 2025 meeting to allow for additional refinement by
the Applicant. The project received Preliminary Approval at the January 7, 2025 meeting.
BOARD ACTION MARCH 4, 2025
DRB Vote: Deferral of application for additional refinement and clarification
On March 4th, the Design Review Board (DRB) voted to defer the application for the Magnolia
Residences on West Broad Street. This decision was made to give the applicant time to address the
DRB – Meeting Minutes – 2025-04-01
Page 2 of 7
comments made by the Board. A summary of the Board's feedback was provided to help the design
and development team respond to the recommendations, which can be found in the attached materials
from the applicant.
RECOMMENDATION
A Final Approval by the DRB is recommended.
AUTHORITY & APPLICABILITY
This project is zoned D-T5 and is a full site redevelopment. Formal design review and approval by the
Design Review Board is required.
DETERMINATION OF COMPLETENESS
• Application is complete.
EXCEPTIONS REQUIRED & PREVIOUSLY APPROVED
• 4.2 Required Shopfront designation: To exclude these frontages from compliance with the
required shopfront designations (proposed as exclusively residential frontage conditions). – Approved
at the 1/7/25 DRB Meeting.
• 7.1.4.b. Parking Area Access: To permit access to parking from the primary frontage. – Approved
at the 1/7/25 DRB Meeting.
CODE REVIEW
Deficiencies noted, or exceptions or deviations required, are noted in blue italics
A. Use Standards: The proposed use (office) is permitted by right in D-T6.
B. District Standards:
• 3.3.1 Lot Configuration: Frontage Build-Out: 60% except in Side Yard Parking Overlay –
Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4.a Building Height: Compliant
• 3.3.5 Permitted Parking Location: Compliant
• 3.3.6 Building Frontage: Shopfront – Permitted
C. General Standards:
• 4.2 Required Shopfront Designation: The frontages of Daniel Morgan Avenue and Spring Street are
required to have ground-floor commercial frontages supported by Shopfront & Awning, Gallery, or
Arcade frontages. Exception approved at the 1/7/25 DRB Meeting.
D. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space - Compliant
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian
entrances on a frontage line. - Compliant
• 5.1.4 Setbacks: Front and side setbacks must be consistent with surrounding buildings. - Compliant
• 5.1.5 Adjacent Lots: Grading between lots to be sensitively considered. – Not Applicable
E. Utilities and Trash Containment:
DRB – Meeting Minutes – 2025-04-01
Page 3 of 7
• 5.2.1 Underground Utilities: Compliant
• 5.2.2 Solid Waste Storage Areas: Compliant
• 5.2.3 Mechanical and Utility Equipment: Compliant
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: Compliant
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Compliant
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Compliant
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant.
• 6.4 Specific Building Design Standards for all D-T5 Mixed-Use and Commercial Buildings
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments: Compliant
o 6.4.4 Ground Level Detailing: 60% Glazing in Transparency. Compliant
o 6.4.5 Materials: Compliant
G. Parking:
• 7.1 Parking Area Access: Parking must be accessed from a rear alley or a secondary frontage unless
approved as a Discretionary Review. (D-T5 & D-T6) – There is a parking access from the primary
frontage of Broad Street. – Exception approved at the 1/7/25 DRB Meeting.
• 7.2 Bicycle Parking: Compliance to be confirmed with Final approval.
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape:
o D-T6: 12 ft zone with 8 ft wide sidewalk and trees in wells: Compliant
• 8.2 Parking Area Landscaping: Not applicable
I. Signage: Staff level approval
Applicant:
Chris Van Kley, Dwell Design Studio.
Public Comments: None.
Discussion:
Based on the materials reviewed in the submitted packet and the applicant’s response to comments
from the previous meeting, the Board noted that the revised design has addressed prior concerns.
Members appreciated the new, more traditional posts, which better harmonize with the rear balconies
rather than competing with them. The revisions to the lobby area were also well-received.
Additionally, the inclusion of two new perspective views from Daniel Morgan Avenue helped
DRB – Meeting Minutes – 2025-04-01
Page 4 of 7
illustrate the transition from the more active two-story frontage to the quieter alley side, which now
appears more natural and contextually appropriate.
A motion was made by Ms. Babcock, seconded Mr. Newman for Full & Final approval by a vote
of 5-0.
DRB-25-020-00002 – The Design Review Board (DRB) has received a request for Preliminary
Conceptual Approval for the proposed building, Townes of Howard, located at 535 Howard
Street (Tax Map Sheet: 7-12-05-113.00) with a zoning designation of DT-4 Zone (Downtown
Urban District). Owner: GVL Property Group, LLC / Agent: Bryan De Bruin, VanRock
Holdings.
A motion was made by Ms. Babcock, seconded Mr. Hauser for a file the application without
prejudice by a vote of 5-0.
DRB-25-020-00003 – The Design Review Board (DRB) has received a request for Preliminary
Conceptual Approval for the proposed development, Spartanburg County / City
Administration, located at 145 W Broad St (Tax Map Sheet: 7-12-20-056.00, 7-12-24-001.00, 7-
12-21-062.00, 7-12-24-002.00, 7-12-21-063.00, 7-12-21-064.00, 7-12-21-066.00, 7-12-21-067.00, 7-
12-21-069.01, 7-12-21-069.00, 7-12-24-004.00, 7-12-24-003.00, and 7-12-24-003.01) with a zoning
designation of DT-5 Zone (Downtown Urban District). Owner: City of Spartanburg / Agent:
Michael Schwartz, McMillan Pazdan Smith.
GENERAL PROJECT OVERVIEW
The proposed redevelopment along West Broad Street and South Church Street is for a 5 (five) story
City/County Administration office building. The next phase, the planned mixed-use building and
shared parking structure to the west is not included in this review. This is the first review for
Preliminary Approval.
AUTHORITY & APPLICABILITY
This project is zoned D-T5 and is a full site redevelopment. Formal design review and approval by the
Design Review Board is required.
DETERMINATION OF COMPLETENESS
Application is complete.
FINDINGS- EXCEPTIONS
• 6.4.4.a Minimize Blank Walls & 6.4.4.c.2 Transparency Zone: To permit in excess of 20 feet of
building that lacks transparent windows or doors not exceeding maximum four (4) feet in height above
the sidewalk grade along West Broad Street and South Church Street and to have less than 60% of
total frontage in ground-level transparent glazing.
CODE REVIEW
Deficiencies noted, or exceptions or deviations required, are noted in blue italics
A. Use Standards: The proposed use (office) is permitted by right in D-T6.
DRB – Meeting Minutes – 2025-04-01
Page 5 of 7
B. District Standards:
• 3.3.1 Lot Configuration: Frontage Build-Out: 60% except in Side Yard Parking Overlay –
Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4.a Building Height: Compliant
• 3.3.5 Permitted Parking Location: Compliant
• 3.3.6 Building Frontage: Shopfront – Permitted
C. General Standards:
• 4.1. Civic/Landmark Buildings: Compliant except (f) below
i. If indicated on the Downtown Master Plan, they must comply with the recommendations
therein. Compliant
ii. They should be sited to terminate a street vista whenever possible and must incorporate
appropriate prominent features, designs, and entrances to celebrate a visual termination.
Compliant
iii. They should incorporate detailing and materials that are authentic to the intended style.
Compliant
iv. A pedestrian plaza, courtyard, or similar landscaped area may be substituted for a required
building frontage and minimum setback line. Compliant
v. Building entrances for civic buildings may be raised above the street elevation and accessed
via a monumental stair. Compliant
vi. They should respect the character of the fronting streets through the provision of a
pedestrian friendly orientation including clear entrances from the street and permeable street
walls with adequate windows (no blank walls). See note regarding exception to Section 6.4.4
D. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space - Compliant
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian
entrances on a frontage line. - Compliant
• 5.1.4 Setbacks: Front and side setbacks must be consistent with surrounding buildings. - Compliant
• 5.1.5 Adjacent Lots: Grading between lots to be sensitively considered. – Compliant
E. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Presumed Compliant
• 5.2.2 Solid Waste Storage Areas: Presumed Compliant- will be confirmed at the staff review level
• 5.2.3 Mechanical and Utility Equipment: Presumed Compliant
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: See note regarding façade transparency.
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Compliant
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Compliant
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
DRB – Meeting Minutes – 2025-04-01
Page 6 of 7
• 6.4 Specific Building Design Standards for all D-T5 Mixed-Use and Commercial Buildings
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments: Compliant
o 6.4.4 Ground Level Detailing: 60% Glazing in Transparency. Exception required
o 6.4.5 Materials: Compliant
G. Parking:
• 7.1 Parking Area Access: Parking must be accessed from a rear alley or a secondary frontage unless
approved as a Discretionary Review. (D-T5 & D-T6) – Compliant
• 7.2 Bicycle Parking: Compliance to be confirmed with Final approval
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape:
o D-T5: 16 ft zone with 16 ft wide sidewalk and trees in wells: Compliant
• 8.2 Parking Area Landscaping: Not applicable
I. Signage: Staff level approval
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
6.4.4 Ground Level Detailing: The proposed window spacing and proportions are appropriate for a
civic/office building. However, the frontages along West Broad Street and South Church Street do not
meet minimum standards of 60% transparency and there is also a series of retaining walls that
represent a blank wall condition.
The transparency is a minimum of 51% glazing for South Church Street and 39% for West Broad
Street. The spaces behind these windows are predominately office/occupied spaces.
The retaining wall across the southern portion of the South Church Street frontage has been designed
with high quality materials and ground-level plantings to help soften the transition. The treatment is
appropriate to building and does not compromise the streetscape.
RECOMMENDATION
A Preliminary Approval by the DRB will require the following exceptions:
• 6.4.4.a Minimize Blank Walls & 6.4.4.c.2 Transparency Zone: To permit in excess of 20
feet of building that lacks transparent windows or doors not exceeding maximum four (4) feet
in height above the sidewalk grade along West Broad Street and South Church Street and to
have less than 60% of total frontage in ground-level transparent glazing.
Applicant:
Adam Flynn, McMillan Pazdan Smith.
Public Comments:
Stephen Sykes, 205 Woodgrove Trace.
Discussion:
The Board discussed several key elements of the proposed design. Members emphasized the
importance of preserving an 8-foot sidewalk with tree wells and requested inclusion of street lighting
and site features within the plans. They would like to see a revised design that clearly shows the street
lighting layout, the pull-up/drop-off zone, and added parking, ensuring compliance with the 4-foot
clear zone requirement.