Design Review Board - 650 Howard St. - DR. TK Gregg Recreation Center — Agenda Packet
City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of Dec 3, 2024 · Agenda packets
Open the original document More from City of Spartanburg
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
The City of Spartanburg
Design Review Board
City of Spartanburg | Design Review Board Agenda 1
AGENDA
December 3rd, 2024, at 5:30 P.M.
Dr. TK Gregg Community Center
650 Howard Street – Spartanburg, SC 29303
(Please Note:
Items as they appear on the Docket may or may not be considered in the order as they are
presented. The Chairperson will announce any changes after the roll call).
I. Roll Call.
II. Freedom of Information Act Compliance – Public notification of the Design Review Board meeting
has been published, posted and mailed in compliance with the Freedom of Information Act and the
requirements of the City of Spartanburg Zoning Ordinance.
III. Approval of Agenda.
IV. Disposition of the Minutes of November 5th, 2024, meeting.
V. Old Business:
1. DRB-24-020-00014 – The Design Review B
oard (DRB) has received a request for Full and Final
Approval for the proposed building, 276 Magnolia Street located in the DT-5 Zone (Downtown Urban
District) at 276 Magnolia St (Tax Map Sheet: 7-12-06-015.00). Owner: Pat Knie / Applicant: Meghan
Teague, Studio Teague, LLC.
2. DRB-24-020-00016 – The Design Review
Board (DRB) has received a request for Full and Final
Approval for the proposed building, Shulikov Law Firm, located at 251 Magnolia St (Tax Map
Sheet: 7-12-06-041.00) with a zoning designation of DT-5 Zone (Downtown Urban District).
Owner: Tatyana Shulikov
/ Agent: Amanda Metze.
VI. New Business:
1. DRB-24-020-00018 – The Design Review
Board (DRB) has received a request for Preliminary
Conceptual Approval for the proposed building, Grain District Office Building, lo
cated at 245 W Main
Street (Tax
Map Sheet: 7-12-14-005.00) with a zoning designation of DT-5 Zone (Downtown Urban
District). Owner: Morgan & Henry JOF ESA LLC / Agent: Andrew McCall & William Gray,
2. DRB-24-020-00015 – The Design Review B
oard (DRB) has received a request for Full and Final
Approval for the Morgan Square Enhancement Plan. Owner: City of Spartanburg / Applicant:
MKSK. McMillan Pazdan Smith
Architecture.
3. DRB-24-020-00017 – The Design Review Board (DRB) h
as received a request for Preliminary
Conceptual Approval for the proposed Building, Danbury Commons located at 203 Fremont
Avenue (Tax Map Sheet: 7-12-01-080.00) w
ith a z
oning designation of DT-4 Zone (Downtown
Urban District) Owner: Dialysis Clinic Inc / A
pplicant: Field Goodlett, Connelly
Development, LLC.
4.
The City of Spartanburg
Design Review Board
City of Spartanburg | Design Review Board Agenda 2
VII. Staff Announcements:
VIII. Adjournment.
For more information, please contact the City of Spartanburg Planning Department at
planning@cityofspartanburg.org or call (864) 596-2068.
Planning Department
PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596 -2068 • email: planning@cityofspartanburg.org
website: www.cityofspartanburg.org
276 Magnolia Street -DRB – December 3, 2024
ADDRESS/ TAX ID
276 Magnolia Street/7-12-06-015.00
TO
Spartanburg Design Review Board
DATE
11.26.24
PROJECT NUMBER
DRB-24-020-00014
COPIES TO
City Departments
Applicant
STAFF
Fredalyn M. Frasier, Planning Director
Nan Zhou, AICP, Planner II
Craig Lewis, FAICP – Technical Advisor
OWNER/APPLICANT
Pat Knie/ Meghan Teague, Studios Teague, LLC.
GENERAL PROJECT OVERVIEW
The applicant is seeking to renovate an existing two-story commercial building as a ground-floor office and an
upper story apartment. This is the Final Review for approval.
AUTHORITY & APPLICABILITY
This project is zoned DT-5. Formal design review and approval by the Design Review Board is required due to the
new addition of the elevator core to the side and the riser room to the rear.
DETERMINATION OF COMPLETENESS
Application is complete.
FINDINGS - EXCEPTIONS
• None Requested.
CODE REVIEW
A. Applicability Matrix: Because this is a minor expansion that is less than 25% of the total floor area, the
project is required to comply with the following: Solid waste storage areas, Bicycle parking, Streetscaping,
and Signage; and Site Landscaping to the greatest extent possible.
B. Use Sta
ndards: The proposed use is permitted by right.
C. District S
tandards:
• 3.3.1 Lot Configuration: Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Not applicable
• 3.3.6 Building Frontage: Shopfront – permitted
D. General Stand
ards:
• Not applicable
276 Magnolia Street -DRB – December 3, 2024
E. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space. Compliant
• 5.2.2 Solid Waste Storage Areas: All trash containment devices, including compactors and
dumpsters, must be located and designed so as not to be visible from the view of nearby streets
and properties. Screening, where required, must meet the requirements of Section 505.63. If the
device is not visible from a public right-of-way or park, then it need not be s creened. –Compliant
F. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliant
• 5.2.2 Solid Waste Storage Areas: Not applicable
• 5.2.3 Mechanical and Utility Equipment: Compliant
G. Building Standards:
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill and Redevelopment: Compliant
• 6.1.4 General Design Principles – Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Compliant
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant
• 6.4 Specific Building Design Standards for Mixed-use and Commercial Buildings in D-T5 (option b)
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments:
Compliant
o 6.4.4 Ground Level Detailing: Compliant
o 6.4.5 Materials: Compliant
H. Parking:
• 7.2 Bicycle Parking: A minimum of 2 bicycle parking spaces shall be provided. Bicycle parking is
not shown on the submitted plans. Please provide.
I. Streetscape and Site Landscaping:
• 8.1 Required Streetscape: 12 ft streetscape zone with a minimum 8 ft sidewalk and trees planted
in wells consistent with downtown standards (40 ft on-center) – Not Applicable due to the
placement of the building and the existing sidewalk.
• 8.2 Site Landscaping: 1 shade tree and eight shrubs per 10 parking spaces. No parking space shall
be further than 60 from a canopy tree. Please note compliance for Final Approval.
J. Signage: Not applicable.
276 Magnolia Street -DRB – December 3, 2024
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
NONE.
RECOMMENDATION
The applicant has provided sufficient compliance detail for a Final Approval.
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
DOWNTOWN OFFICE MIXED-USE
renovating an existing office building at 276 Magnolia Street in downtown Spartanburg.
PROJ. NO.
DATE:
SKETCH NO.
DOWNTOWN MIXED USE
SD5
11/10/2023
23037
FIRST FLOOR PLAN -
OPTIONS276 MAGNOLIA STREET
1/8" = 1'-0"SD5
1 Elevation 3 - a
SD5
2 3D View 1
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
URBAN CONTEXT
MAGNOLIA
CEMETARY
AMTRAK
SPARTANBURG
STATION
NOT IN USE
LIQUOR STORE
VCOM CAMPUS
FARMERS
MARKET
4 SEASON
PARK
276 MAGNOLIA
STREET
HAIR SALON
KRISPY KREME
SPARTANBURG
TREASURERS
OFFICE
SPARTANBURG
MEMORIAL
AUDITORIUM
SPARTANBURG
COUNTY
COURTHOUSE
COMPLEX
LAWYER
OFFICES
SPARTANBURG
MARRIOT
LOFT
APARTMENTS
RESTAURANT
RICHARDSON PARK
SOCIAL
SECURITY
ADMINISTRATION
PARKS AND
RECREATION
BARNET PARK
FR8 YARD
DENNYS
HEADQUARTERS
SPARTANBURG
COMMUNITY
COLLEGE
DENNY’S
PLAZA
FIRST BAPTIST
CHURCH
STUDENT CENTER FIRST BAPTIST
SPARTANBURG
CHURCH COMPLEX
SPARTANBURG SCIENCE
AND CHAPMAN
CULTURAL CENTER
Vicinity Map
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
URBAN CONTEXT
MAGNOLIA
CEMETARY
AMTRAK
SPARTANBURG
STATION
NOT IN USE
NOT IN USE
NOT IN USE
LIQUOR STORE
VCOM CAMPUS
4 SEASON
PARK
276 MAGNOLIA
STREET
HAIR SALON
KRISPY KREME
RESTAURANT
SPARTANBURG
COUNTY
COURTHOUSE
COMPLEX
LAWYER
OFFICES
LAWYER
OFFICES
SPARTANBURG
MARRIOT
LOFT
APARTMENTS
SPARTANBURG
COUNTY
COURTHOUSE
COMPLEX
Proximity Map
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
URBAN CONTEXT
photographs from north side of Magnolia Street looking southproject site
photographs from site looking north
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
PROJ. NO.
DATE:
SKETCH NO.
DOWNTOWN MIXED USE
SD5
11/10/2023
23037
FIRST FLOOR PLAN -
OPTIONS
276 MAGNOLIA STREET
1/32" = 1'-0"
SD5
1
SITE PLAN
DOWNTOWN CODE COMPLIANCE
Code
Section Section Title Requirement Compliance
3.1.4 Use Standard by Zone ✓
3.3 District Standards
3.3.2 Primary Building Standards 0 - 24' ✓
6.4 Specific Building Design Standards
6.4.1 Roof and Eaves
a. flush eaves must be finished by profiled
molding or gutters.
✓
b. All rooftop equipment must be screened from
view
✓
6.4.3 Ground Level Detailing
a. Minimize Blank Walls: Expanses of blank walls
may not exceed 20 feet in length. (A "blank wall"
is a facade that does not contain transparent
windows or doors.)
NO CHANGE ✓
b. Ground-Level Glazing: Window glazing and
doorways must be the predominant features in
the street-level facade. Exterior burglar bars,
fixed "riot shutters,” or similar security devices
must not be visible from the public right-of-way.
All ground level windows must provide direct
views to the building’s interior extending a
minimum of 6 feet behind the window.
NO CHANGE ✓
c. Transparency Zone: Glazing that is transparent
under all lighting conditions must extend from a
base of contrasting material (not exceeding four
(4) feet in height above the adjacent grade) to at
least the height of the door head. However,
spandrel or colored glass may be used above the
height of the door head. Glazing must extend
from the corner of the front facade for a depth
equal to: 1. Shopfront Frontage Transparency per
Section 4.2: At least seventy (70) percent of the
length of building along all street side building
facades.
NO CHANGE ✓
6.4.4 Materials
Commercial building walls must be brick, pre-cast
concrete, cut stone (residential applications such
as field stone and ledge stone are prohibited),
cementitious fiber board, or wood clapboard.
Regular or decorative concrete block and EIFS-
type stucco may be used on building walls not
visible from a public street or as an accent
material only. All accessory buildings must be
clad in materials similar in appearance to the
principal structure.
✓
8.1 Required Streetscape
NO CHANGE ✓
Spartanburg Downtown Code Compliance for 276 Magnolia
DT-5 - gateway corridors and blocks surrounding the downtown core
BUSINESS /
DWELLING
existing building footprint to remain;
floor level even to sidewalk level
existing sidewalks
existing vegetation to remain
SITE + BUILDING FOOTPRINT @ 1/32” = 1’-0”
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
1ST FLOOR @ 1/8” = 1’-0”
A300
1
A300
3
A3002
LOBBY
100
RECEPTION
101
OFFICE
102 OFFICE
106
RESTROOM
107
RESTROOM
108
OFFICE
109
STORAGE / WORK
ROOM
110
OFFICE
111
BREAK ROOM
112
REAR FOYER
113
OPEN OFFICE AREA
103
CORRIDOR
105
STAIR
114
CLOSET
104
CLOSET
115
- NOT IN SCOPE -
- NOT IN SCOPE -
ELEVATOR
6' - 2 1/2"
RISER ROOM
116
OWNER ENTRY
FOYER
118
36' - 6"
4' - 0"
6' - 3"
PROJ. NO.
DATE:
SKETCH NO.
DOWNTOWN MIXED USE
SD5
11/10/2023
23037
FIRST FLOOR PLAN -
OPTIONS276 MAGNOLIA STREET
1/8" = 1'-0"SD5
1 First Floor Copy 2
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
SECOND FLOOR PLAN @ 1/8” = 1’-0”A300
1
A300
3
A3002
PANTRY
LIVING ROOM
DINING AREA KITCHEN
BATH 2
BEDROOM 2
PRIMARY BEDROOM
PRIMARY BATH
W/D
REF.
ELEVATOR
OFFICE
PRIMARY CLO.1
PRIMARY CLO.2
PROJ. NO.
DATE:
SKETCH NO.
DOWNTOWN MIXED USE
SD5
11/10/2023
23037
FIRST FLOOR PLAN -
OPTIONS276 MAGNOLIA STREET
1/8" = 1'-0"SD5
1 SECOND FLOOR - PROPOSED PLAN Copy 1
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
PROJ. NO.
DATE:
SKETCH NO.
DOWNTOWN MIXED USE
SD5
11/10/2023
23037
FIRST FLOOR PLAN -
OPTIONS276 MAGNOLIA STREET
1/8" = 1'-0"SD5
1 Elevation 3 - a
SD5
2 3D View 1
NORTH ELEVATION @ 1/8” = 1’-0”
EXISTING FRONT ELEVATION
NORTH PERSPECTIVE
VIEW FROM STREET
BUILDING DESIGN
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
WEST ELEVATION @ 1/8” = 1’-0”
EXISTING EAST ELEVATION IMAGE
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
EAST ELEVATION @ 1/8” = 1’-0”
EXISTING EAST ELEVATION IMAGE
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
08/12/2024
276 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
SOUTH ELEVATION @ 1/8” = 1’-0”EXISTING REAR IMAGE
251 Magnolia Street- DRB December 3, 2024
PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org
website: www.cityofspartanburg.org
ADDRESS/ TAX ID
251 Magnolia Street /711396744858
TO
Spartanburg Design Review Board
DATE
11/26/2024
PROJECT NUMBER
DRB-24-020-00016
COPIES TO
City
Departments
Applicant
STAFF
Fredalyn M. Frasier, Planning Director
Nan Zhou, AICP, Planner II
Craig Lewis, FAICP – Technical Advisor
OWNER/APPLICANT
Owner: Tatyana Shulikov / Agent: Amanda Metze, Teaque Studios
GENERAL PROJECT OVERVIEW
The applicant is seeking to renovate and install new windows into a single-story mid-century modern building.
Since Preliminary Review, the applicant has increased the window sizes, added a canopy, and removed the shrubs
to widen the sidewalk zone. This application is for final approval.
AUTHORITY & APPLICABILITY
This project is zoned DT-6. Formal design review and approval by the Design Review Board is required due to the
installation of new windows in the first layer (front of the building).
DETERMINATION OF COMPLETENESS
Application is complete.
FINDINGS - EXCEPTIONS
• None Requested.
CODE REVIEW
Exceptions or deviations required are noted in blue italics.
A. Applicability Matrix: Because this an exterior alteration in the first or second layer without an expansion, the
project is required to comply with the following: Solid waste storage areas and Signage.
B. Use Standards: The proposed use is permitted by right.
C. District Standards:
• 3.3.1 Lot Configuration: Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Not applicable
• 3.3.6 Building Frontage: Shopfront – permitted
Planning Department
251 Magnolia Street- DRB December 3, 2024
D. General Standards:
• Not applicable
E. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space. Compliant
• 5.2.2 Solid Waste Storage Areas: All trash containment devices, including compactors and dumpsters,
must be located and designed so as not to be visible from the view of nearby streets and properties.
Screening, where required, must meet the requirements of Section 505.63. If the device is not visible
from a public right-of-way or park, then it need not be screened. – The location of the trash
containers has not been noted on the plans. We presume the use of standard roll-outs to the rear.
F. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliant
• 5.2.2 Solid Waste Storage Areas: Not applicable
• 5.2.3 Mechanical and Utility Equipment: Compliant
G. Building Standards:
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill and Redevelopment: Compliant
• 6.1.4 General Design Principles – Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Compliant
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant
• 6.4 Specific Building Design Standards for Mixed-use and Commercial Buildings in D-T5 (option b)
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments: Compliant
o 6.4.4 Ground Level Detailing: 64% transparent - Compliant
o 6.4.5 Materials: Compliant
H. Parking:
• 7.2 Bicycle Parking: A minimum of 2 bicycle parking spaces shall be provided. Compliant
I. Streetscape and Site Landscaping:
• 8.1 Required Streetscape: 12 ft streetscape zone with a minimum 8 ft sidewalk and trees planted in
wells consistent with downtown standards (40 ft on-center) – Shrubs have been removed and the
hardscape has been extended to the building to expand the sidewalk width.
• 8.2 Site Landscaping: 1 shade tree and eight shrubs per 10 parking spaces. No parking space shall be
further than 60 from a canopy tree. - Not applicable.
251 Magnolia Street- DRB December 3, 2024
J. Signage: Not applicable.
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
• Brick Painting: Painting of structures and color selection are not formal DRB review items. However,
recommendations are occasionally presented. The Preliminary Review encouraged the applicant to
consider cleaning and repointing the existing brick in lieu of painting.
The existing buff-colored brick and its unique, non-offset coursing is a common detail for mid-century
modern buildings. The style itself is one that is intended to reflect the authenticity of the materials
and to evoke a more horizontal feel to the façade. In addition, because brick is itself a porous
material, painting it, according to the Brick Association, creates a barrier that can trap moisture
inside. For most structures, painted brick requires more frequent maintenance and for some
structures, painting it can cause mold and mildew growth on the interior and exterior.
• The applicant indicated their preference to paint the building and agreed to provide the color sample
of the paint noted in the renderings along with a sample of the window casing during the Full and
Final review.
RECOMMENDATION
The applicant has provided sufficient compliance detail for a Final Approval.
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
DOWNTOWN OFFICE
RENOVATION OF AN EXISTING OFFICE BUILDING AT 251 MAGNOLIA STREET IN DOWNTOWN SPARTANBURG.
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
URBAN CONTEXT
MAGNOLIA
CEMETARY
AMTRAK
SPARTANBURG
STATION
NOT IN USE
LIQUOR STORE
VCOM CAMPUS
FARMERS
MARKET
4 SEASON
PARK
251 MAGNOLIA
STREET
HAIR SALON
KRISPY KREME
SPARTANBURG
TREASURERS
OFFICE
SPARTANBURG
MEMORIAL
AUDITORIUM
SPARTANBURG
COUNTY
COURTHOUSE
COMPLEX
LAWYER
OFFICES
SPARTANBURG
MARRIOT
LOFT
APARTMENTS
RESTAURANT
RICHARDSON PARK
SOCIAL
SECURITY
ADMINISTRATION
PARKS AND
RECREATION
BARNET PARK
FR8 YARD
DENNYS
HEADQUARTERS
SPARTANBURG
COMMUNITY
COLLEGE
DENNY’S
PLAZA
FIRST BAPTIST
CHURCH
STUDENT CENTER FIRST BAPTIST
SPARTANBURG
CHURCH COMPLEX
SPARTANBURG SCIENCE
AND CHAPMAN
CULTURAL CENTER
VICINITY MAP
N
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
URBAN CONTEXT
PHOTOGRAPHS FROM SOUTH SIDE OF MAGNOLIA ST LOOKING NORTHproject site
PHOTOGRAPHS FROM SITE LOOKING SOUTH ALONG MAGNOLIA ST
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
31' - 8 3/4"
5' - 4 1/2"
DOWNTOWN CODE COMPLIANCE
Code
Section Section Title Requirement Compliance
3.1.4 Use Standard by Zone ✓
3.3 District Standards
3.3.2 Primary Building Standards 0 - 24' ✓
6.4 Specific Building Design Standards
6.4.1 Roof and Eaves
a. flush eaves must be finished by profiled
molding or gutters.
✓
b. All rooftop equipment must be screened from
view
✓
6.4.3 Ground Level Detailing
a. Minimize Blank Walls: Expanses of blank walls
may not exceed 20 feet in length. (A "blank wall"
is a facade that does not contain transparent
windows or doors.)
NO CHANGE ✓
b. Ground-Level Glazing: Window glazing and
doorways must be the predominant features in
the street-level facade. Exterior burglar bars,
fixed "riot shutters,” or similar security devices
must not be visible from the public right-of-way.
All ground level windows must provide direct
views to the building’s interior extending a
minimum of 6 feet behind the window.
NO CHANGE ✓
c. Transparency Zone: Glazing that is transparent
under all lighting conditions must extend from a
base of contrasting material (not exceeding four
(4) feet in height above the adjacent grade) to at
least the height of the door head. However,
spandrel or colored glass may be used above the
height of the door head. Glazing must extend
from the corner of the front facade for a depth
equal to: 1. Shopfront Frontage Transparency per
Section 4.2: At least seventy (70) percent of the
length of building along all street side building
facades.
NO CHANGE ✓
6.4.4 Materials
Commercial building walls must be brick, pre-cast
concrete, cut stone (residential applications such
as field stone and ledge stone are prohibited),
cementitious fiber board, or wood clapboard.
Regular or decorative concrete block and EIFS-
type stucco may be used on building walls not
visible from a public street or as an accent
material only. All accessory buildings must be
clad in materials similar in appearance to the
principal structure.
✓
8.1 Required Streetscape
NO CHANGE ✓
Spartanburg Downtown Code Compliance for 276 Magnolia
DT-5 - gateway corridors and blocks surrounding the downtown core
BUSINESS /
DWELLING
existing building footprint to remain;
scope of architectural work is exterior
front facade only
remove existing planters, hardscape to
building
(1) inverted “U” bicycle parking spot
existing street tree to remainSITE + BUILDING FOOTPRINT @ 1/32” = 1’-0”
N
MAGNOLIA STREET
E DANIEL MORGAN AVE
NO CHANGE
NO CHANGE
NO CHANGE
NO CHANGE
NO CHANGE
WINDOWS ADDED
WINDOWS ADDED
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
31' - 8 3/4"
5' - 4 1/2"
7' - 9 1/2"
6' - 6"
7' - 9 1/2"
6' - 6"
4' - 9 1/4"31' - 8 3/4"
AREA FOR SIGNAGE
SIGNAGE BY OTHERS
NORTH ELEVATION @ 1/4” = 1’-0”
FRONT FACADE DEMO PLAN @ 1/8” = 1’-0’’ FRONT FACADE PROPOSED PLAN @ 1/8” = 1’-0’’
EXISTING FRONT ELEVATION
BUILDING DESIGN
clean + paint facade;
color: SW Natural Choice
existing metal cap flashing;
color: dark bronze
new storefront windows to align with brick coursing
color: SW Iron Ore
storefront entry with awning
remove existing brick planter
remove existing interior
storefront door + sidelites
existing storefront to remain;
color: clear anodized
hardscape to building
demo for new window
openings
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
MATERIAL PALETTE
Brick, painted
Sherwin Williams - Natural Choice
Storefront, painted
Sherwin Williams - Iron Ore
Material palette example
TEAGUE STUDIO
ARCHITECTURE + DESIGN
www.studioteague.com | 864.310.4327
DRB Preliminary Review
10/01/2024
251 MAGNOLIA
SPARTANBURG, SC
BUILDING DESIGN
PROPOSED FACADE CHANGES - RENDER
AREA FOR SIGNAGE
SIGNAGE BY OTHERS
245 W. Main Street-Grain District Office- DRB December 3, 2024
PO Box 1749 •
Spartanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org
website: www.cityofspartanburg.org
ADDRESS/ TAX ID
245 W. Main Street/7-12-14-005.00
TO
Spartanburg Design Review Board
DATE
11/26/2024
PROJECT NUMBER
DRB-24-020-00018
COPIES TO
City
Departments
Applicant
STAFF
Fredalyn M. Frasier, Planning Director
Nan Zhou, AICP, Planner II
OWNER/APPLICANT
Owner: Morgan & Henry JOF ESA LLC / Agent: Andrew McCall & William Gray
GENERAL PROJECT OVERVIEW
The proposed 7 story, ~136,000 square foot office building is located at the corner of West Main Street and Batters
Alley adjacent to the 10 story AC Hotel. Below-grade parking is proposed with access from Batter’s Alley. It is a part
of a larger development that includes the Fifth Third Park and a Parking Garage (both under construction). This is the
first review for Preliminary Approval.
AUTHOR
ITY & APPLICABILITY
This project is zoned D-T5 and is a full site redevelopment. Formal design review and approval by the Design Review
Board is required.
DETERMINATION OF COMPLETENESS
Application is complete.
FINDIN
GS - EXCEPTIONS
• 3.3.4 Building Height: To permit a 7 story building (maximum height is 6 stories in DT-5) subject to the height
bonuses in Section 3.5 (3.5.1 Green Building Height Bonus or 3.5.2 Mixed-use Building Height Bonus).
• 6.4.4.a Minimize Blank Walls & 4.4.4.c.2 Transparency Zone: To permit in excess of 20 feet of building that
lacks transparent windows or doors not exceeding maximum four (4) feet in height above the sidewalk
grade.
• 8.1 Minimum Streetscape Zone: To permit a sidewalk zone along West Main Street that is less than 12 feet in
total width (shown as 10 ft 3 in between the retaining wall and the edge of curb) and sidewalk that is less
than 8 feet in total width (6 ft 3 in). And, to permit a sidewalk zone along Batter’s Alley that is 9 ft 4 in (total)
and a 5 ft wide sidewalk.
Planning Department
245 W. Main Street-Grain District Office- DRB December 3, 2024
CODE REVIEW
Exceptions or deviations required are noted in blue italics.
A. Use Standards: The proposed use (office) is permitted by right in D-T5.
B. District Standards:
• 3.3.1 Lot Configuration: Frontage Build-Out: 60% except in Side Yard Parking Overlay – Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4 Building Height: Exception required for 7 story building (1 additional story over maximum height
in DT-5) subject to height bonuses in 3.5.
• 3.3.5 Permitted Parking Location: Compliant
• 3.3.6 Building Frontage: Shopfront (?) – Permitted; Partial Arcade (?) at corner - Permitted
C. General Standards:
• Compliant
D. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space - Compliant
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian entrances
on a frontage line. - Compliant
• 5.1.4 Setbacks: Front and side setbacks must be consistent with surrounding buildings. - Compliant
• 5.1.5 Adjacent Lots: Grading between lots to be sensitively considered. – Not Applicable
E. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliant
• 5.2.2 Solid Waste Storage Areas: Compliance to be confirmed with final approval
• 5.2.3 Mechanical and Utility Equipment: Compliance to be confirmed with final approval
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: See note regarding the provision of interesting and
active frontages.
• 6.1.2 General Design Principles - Housing: Not applicable
• 6.1.3 General Design Principles – Mixed-Use Infill & Redevelopment: Compliant
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: See note regarding ground floor activity 6.1.5.B)
and wide sidewalks (6.1.5.C)
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant. However, corner buildings are encouraged to have a
corner entrance.
• 6.4 Specific Building Design Standards for all D-T 5 Mixed-Use and Commercial Buildings
o 6.4.1 Roof and Eaves: Compliant; Rooftop equipment screening to be confirmed with Final
Approval
o 6.4.2 Canopies/Awnings: Not Applicable
245 W. Main Street-Grain District Office- DRB December 3, 2024
o 6.4.3 Encroachments: Exception required - The proposed arcade encroachment is not
permitted.
o 6.4.4 Ground Level Detailing: 60% Glazing in Transparency. Exception required - Because the
ground floor windows are elevated more than 4 feet above the sidewalk, they do not qualify
as transparent
elements. The proposed retaining would be considered a blank wall.
o 6.4.5 Materials: Compliant
G. Parking:
• 7.1 Parking Area Access: Parking must be accessed from a rear alley or a secondary frontage unless
approved as a Discretionary Review. (D-T5 & D-T6) – Compliant
• 7.2 Bicycle Parking: Compliance to be confirmed with Final approval.
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape:
o D-T5:
12 ft zone with 8 ft wide sidewalk: Compliant along Grove Street only. Exception
required – Proposed streetscape
along West Main Street is less than 12 feet in total width
(shown as 10 ft 3 in between the retaining wall and the edge of curb) and sidewalk that is less
than 8 feet in total width (6 ft 3 in). The current design incorporates an elevated pathway
along W. Main Street. The sidewalk zone along Batter’s Alley is 9 ft 4 in (total) and a 5 ft wide
sidewalk.
• 8.2 Parking Area Landscaping: Not applicable
I. Signage: Staff level approval
ADDITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
Building Height: The Design Review Board shall use the incentives noted in Section 3.5 as guidelines in their review
but shall also have the discret ion to ensure that the overall scale, massing, and frontage of the structure is compatible
with other structures within adjacent blocks. Height exceptions are permitted subject to compliance with one of the
height bonus options LEED Certification, Mixed-Use, or through a rezoning to DT-6. In this instance, a restaurant is
proposed for the office building.
Arcade Treatment: The proposed “arcade” creates a unique right-of-way condition for Batter’s Alley. The arcade will
require a permanent pedestrian easement (or similar document) for the applicant to provide City and the general
public unrestricted access.
245 W. Main Street-Grain District Office- DRB December 3, 2024
Blank Wall and
Building Transparency: Because the building is set to the zero grade along the side street (Grove
Street) and not along the Main Street, the Main Street frontage has resulted with a series of stairs and retaining walls.
A variation will be required as the building is set up above the curb and the bottom of the windows are more than 4
feet above the sidewalk grade, the retaining wall areas are not contributing to the transparency requirement and
essential create a “blank wall” across most of the frontage.
• Precedent exists for a variation given site topography.
Streetscape: The proposed streetscape along Groce does meet the standards for DT-4 with a minimum 14 foot width
streetscape and 8 foot clear sidewalk. However, the proposed public sidewalk conditions along W. Main Street and
Batter’s Alley do not meet the minimum requirement.
The minimum streetscape dimensions require 12 feet in total width with a minimum sidewalk that is 8 feet in total
width. As proposed, the design incorporates an elevated patheway. However, the W. Main Street streetscape as
measured from ground level is only approximately 10 feet 3 inches between the retaining wall and the edge of curb)
and sidewalk appears to be only 6 feet 3 inches. Batter’s Alley is proposed to be 9 feet 4 inches with a 5-foot-wide
sidewalk.
• Further exploration of design concepts that enhance the pedestrian amenities, specifically along W.
Main Street, and eliminate the sidewalk pinch created by the tree wells and parking spaces is
recommended. The City’s goal is to enhance the pedestrian environment and movement, recognizing
the redevelopment in the immediate area will provide sufficient parking.
RECOMMENDATION
A Preliminary Approval by the DRB will require the following exceptions:
• 3.3.4 Building Height: To permit a 7 story building (maximum height is 6 stories in DT-5) .
• 6.4.4.a
Minimize
Blank Walls & 4.4.4.c.2 Transparency Zone: To permit in excess of 20 feet of building that
lacks
transparent
windows or doors not exceeding maximum four (4) feet in height above the sidewalk grade.
• 8.1 Minimum
Streetscape Zone: To permit a sidewalk zone along West Main Street that is l ess than 12 feet in
total width (shown as 10 ft 3 in between the retaining wall and the edge of curb) and sidewalk that is less
than 8 feet
in total width (6 ft 3 in). And, to permit a sidewalk zone along Batter’s Alley that is 9 ft 4 in (total)
and
a 5 ft wide sidewalk.
• Public/
Pedestrian Easement: To ensure City and public unrestricted acce ss al ong Batter’s Alley and the
building arc
ade.
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Grain District Office Building
Design Review Board Package
COVER PAGE - CONCEPTUAL RENDERING
Grain District Office Building
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Existing Context - Aerial Site Image
EXISTING AERIAL SITE IMAGE
Grain District Office Building
Project Site
N
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Existing Context - Downtown Zoning Map
DOWNTOWN ZONING MAP
Grain District Office Building
DT-5 Zoning
Project Site
N
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Existing Context - Downtown Zoning Map
DOWNTOWN PARCEL AND ZONING MAP
Grain District Office Building
Project Site
PROJECT LOCATION: 316 W MAIN STREET
ZONING CLASSIFICATION DT-5
MAXIMUM LOT COVERAGE: 100%
FRONT SETBACK: 0 FEET MIN / 12 FEET MAX
CORNER SIDE SETBACK: 0 FEET MIN / 12 FEET MAX
INTERIOR SIDE SETBACK: 0 FEET MIN / 24 FEET MAX
REAR SETBACK: 0 FEET MIN
FRONTAGE BUILDOUT: 60% MIN AT SETBACK
BUILDING HEIGHT: 2 STORIES MIN / 6 STORIES MAX
GRAIN DISTRICT OFFICE BUILDING - W MAIN ST
N
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Existing Context - Site Photos
EXISTING SITE PHOTOS
Grain District Office Building
W
M
AIN ST GROCE ST.
S DANIEL MORGAN AVE
BATTERS' ALLEY
PUBLIC PLAZA
POLLARD ST.
EXISTING AC HOTEL
PARKING
EXISTING AC HOTEL
PARKING
GARAGE
SERVICE
YARD
CSX
RAILROAD
TRACKS
FIFTH THIRD
PARK
11/11/2024 4:18:46 PM
GRAIN DISTRICT - OFFICE 1
Spartanburg, SC 11/11/2024
0' 50' 100' 200'
SCALE: 1" = 100'-0"
PROPOSED
7 STORY
BUILDING
11/08/2024
0' 50' 100' 200'
SCALE: 1" = 100'-0"
CONTEXTUAL SITE PLAN
CONTEXTUAL SITE PLAN
Grain District Office Building
12'-0"
12'-0"
OFFICE
2'
+/- 23'
+/- 10'-4" +/- 12'-8"
7'-4" +/- 10'-6"
TREE WELL w/
GRATE, TYP.
4'
13'-6"
11/13/2024 5:43:08 PM
SITE PLAN
GRAIN DISTRICT OFFICE 1 11/12/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
OVERALL SITE PLAN
Grain District Office Building
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
N
11/08/202
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
N
OVERALL SITE PLAN
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
GRADING PLAN
GRADING PLAN
Grain District Office Building
Office Renovation
316 W. Main Street
ST-1
PP
PP
PP
S
S
PAINT
LP
LP
LP
LP
LP
LP
LP
LP
GENERATOR
TRANSFORMER
POWER PANEL
POOL
S
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW ROW
ROW
ROW
ROW
D
BATTERS ALLEY
(CIT
15
GROCE ST
N
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LANDSCAPE PLAN
LANDSCAPE PLAN
Grain District Office Building
UP
UNEXCAVATED
RAMP DOW
N 3%
OPENING
TO
GARAGE
ELEV 1
ELEV 2ELEV 3
ELEV 4
MEP
MEP
MEPSERVICE
PARKING
DASHED LINE OF BUILDING ABOVE
742' - 6"
742' - 6"
741' - 6"
EXISTING
PARKING
GARAGE
SERVICE YARD
11/11/2024 3:29:25 PM
PARKING LEVEL PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
11/08/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 0 - PARKING GARAGE PLAN
Grain District Office Building
UP
UP
DN
UP
185'-0"
W MAIN ST.
EDGE OF
GARAGE
BELOW
ELEV 1
ELEV 2ELEV 3
ELEV 4
OFFICE
OFFICE
GROCE STREET LOBBY
MECHANICAL
ELEC.
SERVICE MAIN STREET
LOBBY
754' - 6"
754' - 6"
OFFICE
11/11/2024 3:29:28 PM
LEVEL 1 PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 1 - FLOOR PLAN
Grain District Office Building
11/08/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
UP
UP
DN
ELEV 1
ELEV 2ELEV 3
ELEV 4
MECHANICAL
ELECTRICAL
OFFICE
DASHED LINE OF CORRIDOR FOR MULTI-
TENANT CONFIGURATION
DASHED LINE OF CORRIDOR FOR MULTI-
TENANT CONFIGURATION
11/11/2024 3:29:29 PM
TYPICAL LEVEL PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVELS 2-7 - TYPICAL FLOOR PLAN
Grain District Office Building
11/08/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
ELEV 1
MECHANICAL ROOF AREA
11/11/2024 3:29:29 PM
ROOF PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
ROOF PLAN
Grain District Office Building
11/08/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
SIGNAGE SIGNAGESIGNAGE
BLADE SIGN
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
EAST ELEVATION
Grain District Office Building
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
SIGNAGESIGNAGE SIGNAGE
BLADE SIGN
BLADE SIGN
NORTH ELEVATION
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
NORTH ELEVATION
Grain District Office Building
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
PARKING LEVEL
742' -6"
BR3
DASHED LINE INDICATES EXTENTS OF SCREEN WALL
BLADE SIGN
SIGNAGE
WEST ELEVATION
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
WEST ELEVATION
Grain District Office Building
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
PARKING LEVEL
742' -6"
PARKING LEVEL
SOUTH ELEVATION
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
SOUTH ELEVATION
Grain District Office Building
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
MT2
EF2
EF1EF1
WN1 WN1
CS2CS2CS2CS2
BR1
CS1CS1
BR1BR1
BR2
WN1 WN1
CS2CS2
BR1
CS2CS2
LF1DR2DR1SF1
SIGNAGE
TYPICAL ELEVATION DETAIL
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"
MATERIALS LEGEND
KEY DESCRIPTION
BR1 Brick Type 1
BR2 Brick Type 2
CS1 Cast Stone Type 1
CS2 Cast Stone Type 2
DR1 Entry Door
DR2 Metal Door, Painted
EF1 Exterior Insulation Finish
EF2 Exterior Insulation Finish System Type 2
LF1 Exterior Decorative Wall Sconce
MT2 Metal Coping
SF1 Aluminum Storefront System
WN1 Fixed Aluminum Window
Entry Door, Aluminum Frame with Glass Panel
Aluminum Frame Door with Glass Panel
Cast Stone/Precast Type 1
Cast Stone/Precast Type 2
Sythentic Stucco 1
Synthetic Stucco 2
TYPICAL ELEVATION DETAIL
Grain District Office Building
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
PARKING LEVEL
742' -6"
16'-0"
116'-0"
TYP.
14'-0" 18'-0" 12'-0"
GROCE STREET
OFFICE OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
GROCE STREET LOBBYOFFICE
PARKING
EXISTING AC HOTEL REAR ENTRANCEEXISTING AC HOTEL LANDSCAPED AREA
BATTER'S
ALLEY
GROCE
STREET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
EXISTING AC HOTEL PARKING
EAST-WEST SECTIONS
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
SECTION AT GROCE STREET LOBBY
SECTION AT AC HOTEL PARKING
EAST - WEST SECTION
Grain District Office Building
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
PARKING LEVEL
742' -6"
16'-0"
TYP.
14'-0"
GRAIN
DISTRICT
PARKING
GARAGE
LANDSCAPE
PLAZA
MAIN
STREET
116'-0"
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
PARKINGMECH.
18'-0"
NORTH-SOUTH SECTION
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
NORTH - SOUTH SECTION
Grain District Office Building
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
Grain District Office, Spartanburg, South Carolina
Proposed Exterior Materials & Colors
BRICK:
RED BRICK, MODULAR
MORTAR COLOR TBD
CAST STONE/PRECAST:
BUFF COLOR RANGE
LIGHT SANDBLAST FINISH
STOREFRONT:
PAINTED METAL FRAME
VISION GLASS:
VITRO: SOLARBAN 72 LOW-E ON CLEAR GLASS
SPANDREL GLASS:
VITRO: SOLARBAN 72 LOW-E ON CLEAR GLASS
WITH WARM GREY FRIT ON SURFACE #4
MECHANICAL SCREEN WALL:
SYNTHETIC STUCCO
SAND FINISH
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
PROPOSED EXTERIOR COLORS AND MATERIALS
Grain District Office Building
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Conceptual Renderings
CONCEPTUAL RENDERING
Grain District Office Building
View from NW across W Main St
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Conceptual Renderings
CONCEPTUAL RENDERING
Grain District Office Building
View from NW down W Main St
JULY 2024
SPARTANBURG, SC
316 W. MAIN STREET
SPARTANBURG, SC
2024
Clayton Construction Company
Office Renovation
316 W. Main Street
EAST ELEVATION
GRAIN DISTRICT OFFICE 1 10/28/2024
0' 8' 16' 32'
SCALE: 1/16" = 1'-0"
Conceptual Renderings
CONCEPTUAL RENDERING
Grain District Office Building
View from SE down Groce St.
12'-0"
12'-0"
OFFICE
2'
+/- 23'
+/- 10'-4"+/- 12'-8"
7'-4"+/- 10'-6"
TREE WELL w/
GRATE, TYP.
4'
13'-6"
11/11/2024 3:29:24 PM
SITE PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
12'-0"
21 sf
8'-1"
SERVICE
YARD
GARAGE
ACCESS
SLIDING
GATE
12'-0"
LOADING ZONE
VARIANCE: BATTERS ALLEY STREETSCAPE WIDTH
VARIANCE & UNIQUE DESIGN CONSIDERATIONS NARRATIVE
Grain District Office Building
Variance & Unique Design Consideration Narrative:
1) Story Height
-DT-5 allows buildings up to 6 stories in height, with approval required for any additional stories, up to 10 stories. The Grain District Office Building proposes a 7-story structure, resulting in a 1-story
variance.
Unique Design Considerations:
The site’s buildable footprint is constrained on all four sides, thus requiring a 7-story building to accommodate the building’s tenant’s space requirements. To the north, along Main Street, the building
matches the setback of the neighboring 10-story AC Hotel Spartanburg. This setback provides the depth required to accommodate a streetscape design that addresses the significant east-to-west
grade change along Main Street. The east side of the building is fixed by a redesigned Groce Street which provides an enhanced pedestrian and vehicular connection to the new Ballpark Plaza.
Groce Street’s width and location are constrained by the existing retaining wall and change in grade of the adjacent AC Hotel parking lot. The south side of the building maintains a minimal setback
from the new parking garage (under construction), whose siting is dictated by the playing field and site requirements of the new Fifth Third Park stadium. To the west, the building’s footprint is
constrained by the existing CSX railroad tracks and Batters Alley which provides the necessary service access to the proposed building, the parking garage and new stadium.
The proposed 7-story height is appropriate for its site located at the intersection of the DT-5 and DT-6 districts; D-T5 zoned parcels (6-story, matter-of-right height limit) are located to the west and
south and D-T6 zoned parcels (10-story, matter-of-right height limit) are immediately across W. Main Street to the north and Groce Street to the east, including the existing 10-story AC Hotel
Spartanburg. Taking into account the lower grade elevations of the site relative to points east, the first-floor elevation of the building is over 14’ (a height of a typical office floor) below that of the
adjacent AC Hotel’s first floor. Overall, the proposed building’s 7-story height will provide a gradual transition in height between the differing heights permitted in each of the two zoning districts.
2) Sidewalk Width
-DT-5 requires an 8'-0" wide sidewalk along street frontages. The Grain District Office Building proposes a 5'-0" wide along the length of Batters Alley, which ties into the 5'-0" sidewalk along the Grain
District Parking Garage, maintaining a consistent width.
Unique Design Considerations:
In contrast to the enhanced pedestrian focus of Groce Street and the Plaza, Batters Alley provides a more service-oriented function with utilities, trash and loading services, and vehicular parking
access to the various buildings along its length. We are proposing an appropriately scaled sidewalk for the anticipated low volume of pedestrian traffic and one that is consistent with the previously
approved sidewalk adjacent the parking garage immediately to the south of the project.
3) Streetscape Width
DT-5 requires a 12'-0" wide streetscape along street frontages. The Grain District Office Building complies with the required width, except for a 21 square foot area as shown, which reduces the
streetscape down to 8'-1" at the narrowest point.
Unique Design Considerations
The constrained site’s footprint and the building’s programmatic needs as noted above, along with the approximately eight feet of grade change across the W. Main Street frontage and
accommodation of truck turning movements, required a unique design approach. While a “Shopfront and Awning” frontage is utilized along the predominant length of W. Main Street, we are proposing
an “Arcade” frontage per Table 1 of the Downtown Code to provide for a 12’ wide streetscape under the northwest corner of the building connecting the pedestrian paths of Batters Alley and W. Main
Street. Due to the non-ninety-degree angle of Batters Alley to W. Main Street, the area requested for variance is limited to a small corner of the north end of the building and maintains the required 8’
sidewalk width through this section.
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
LEVEL 1
754' -6"
LEVEL 2
772' -6"
LEVEL 3
786' -6"
LEVEL 4
800' -6"
LEVEL 5
814' -6"
LEVEL 6
828' -6"
LEVEL 7
842' -6"
ROOF
858' -6"
PARKING LEVEL
742' -6"
11/12/2024 4:01:16 PM
HEIGHT VARIANCE
GRAIN DISTRICT OFFICE 1 11/12/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
EAST ELEVATION NORTH ELEVATION
VARIANCE: STORY HEIGHT
VARIANCE: STORY HEIGHT
Grain District Office Building
11/12/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
Variance Narrative:
1) Story Height
-DT-5 allows buildings up to 6-stories in height, with approval required for any additional stories, up to 10-stories. The Grain District
Office Building proposes a 7-story structure, resulting in a 1-story variance.
2) Sidewalk Width
-DT-5 requires an 8'-0" wide sidewalk along street frontages. The Grain District Office Building proposes a 5'-0" wide along the length
of Batters Alley, which ties into the 5'-0" sidewalk along the Grain District Parking Garage, maintaining a consistent width.
3) Streetscape Width
-DT-5 requires a 12'-0" wide streetscape along street frontages. The Grain District Office Building complies with the required width,
except for a 21 square foot area as shown, which reduces the streetscape width to 8'-1" at the narrowest point.
12'-0"
12'-0"
OFFICE
2'
+/- 23'
+/- 10'-4"+/- 12'-8"
7'-4"+/- 10'-6"
TREE WELL w/
GRATE, TYP.
4'
13'-6"
11/11/2024 3:29:24 PM
SITE PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
5'-0"
SERVICE
YARD
GARAGE
ACCESS
SLIDING
GATE
5'-0"
SIDEWALK
5'-0"
SIDEWALK
LOADING ZONE
SIDEWALK
VARIANCE: BATTERS ALLEY SIDEWALK WIDTH
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
VARIANCE: BATTERS ALLEY SIDEWALK WIDTH
Grain District Office Building
Variance Narrative:
1) Story Height
-DT-5 allows buildings up to 6 stories in height, with
approval required for any additional stories, up to 10
stories. The Grain District Office Building proposes a
7-story structure, resulting in a 1-story variance.
2) Sidewalk Width
-DT-5 requires an 8'-0" wide sidewalk along street
frontages. The Grain District Office Building proposes a
5'-0" wide along the length of Batters Alley, which ties
into the 5'-0" sidewalk along the Grain District Parking
Garage, maintaining a consistent width.
3) Streetscape Width
DT-5 requires a 12'-0" wide streetscape along street
frontages. The Grain District Office Building complies
with the required width, except for a 21 square foot area
as shown, which reduces the streetscape down to 8'-1"
at the narrowest point.
12'-0"
12'-0"
OFFICE
2'
+/- 23'
+/- 10'-4"+/- 12'-8"
7'-4"+/- 10'-6"
TREE WELL w/
GRATE, TYP.
4'
13'-6"
11/11/2024 3:29:24 PM
SITE PLAN
GRAIN DISTRICT OFFICE 1 11/11/2024
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
12'-0"
21 sf
8'-1"
SERVICE
YARD
GARAGE
ACCESS
SLIDING
GATE
12'-0"
LOADING ZONE
VARIANCE: BATTERS ALLEY STREETSCAPE WIDTH
0' 16' 32' 64'
SCALE: 1/32" = 1'-0"
VARIANCE: BATTERS ALLEY STREETSCAPE WIDTH
Grain District Office Building
Variance Narrative:
1) Story Height
-DT-5 allows buildings up to 6 stories in height, with
approval required for any additional stories, up to 10
stories. The Grain District Office Building proposes a
7-story structure, resulting in a 1-story variance.
2) Sidewalk Width
-DT-5 requires an 8'-0" wide sidewalk along street
frontages. The Grain District Office Building proposes a
5'-0" wide along the length of Batters Alley, which ties
into the 5'-0" sidewalk along the Grain District Parking
Garage, maintaining a consistent width.
3) Streetscape Width
DT-5 requires a 12'-0" wide streetscape along street
frontages. The Grain District Office Building complies
with the required width, except for a 21 square foot area
as shown, which reduces the streetscape down to 8'-1"
at the narrowest point.
Morgan Square Pavilions – DRB Dec 3, 2024
PO Box 174
9 • Spartanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org
website: www.cityofspartanburg.org
ADDRESS/ TAX ID
Morgan Square Pavilions/7-12-21-074.00
TO
Spartanburg Design Review Board
DATE
11/26/2024
PROJECT NUMBER
DRB-24-020-00015
COPIES TO
City
Departments
Applicant
STAFF
Fredalyn M. Frasier, Planning Director
Nan Zhou, Planner II
Craig Lewis, FAICP – Technical Advisor
OWNER/APPLICANT
City of Spartanburg, SC/ Applicant MKSK and McMillan Pazdan Smith Architecture
GENERAL PROJECT OVERVIEW
Development of the Morgan Square plan was guided by a select steering committee of local leaders, downtown
stakeholders, and area residents, representing the culmination of nine months of sustained public outreach and
engagement.
The
Morgan Square Pavilion is designed to be a functional and iconic structure at the front door of the Square along
North Church Street and Main Street in Downtown Spartanburg. The location and design of the Pavilion create a focal
point and open views of the Square from the east, an improvement from the existing conditions today that block views
of the Square from Church Street. The Pavilion will be constructed of three individual freestanding buildings and a
monumental freeform canopy above. The three buildings will include a visitors’ information kiosk with a city-employed
information guide, a public toilet facility with 2 fixtures for men and women, and a city storage building. The structures
support the Square’s daily events and programming by enhancing accessibility to public comfort facilities.
The construction of the Morgan Square Pavilion is estimated to begin in the Spring of 2025.
AUT
HORITY & APPLICABILITY
This project is zoned DT-6. Formal design review and approval by the Design Review Board is required of the buildings
only. Any DRB review of the other park elements is customary only and not regulatory. These buildings are considered
under the Civic/Landmark Building standards and shall be subject to Design Review in accordance with Section 2.4. As
part of this review process, the applicant may request modifications from the applicable district standards. However,
all such modifications shall otherwise conform to the general principles for Civic/Landmark buildings below:
• If indicated on the Downtown Master Plan, they must comply with the recommendations therein.
• T
hey should be sited to terminate a street vista whenever possible and must incorporate appropriate
prominent features, designs, and entrances to celebrate a visual termination.
• They should incorporate detailing and materials that are authentic to the intended style.
• A pedestrian plaza, courtyard, or similar landscaped area may be substituted for a required building frontage
and minimum setback line.
• Building entrances for civic buildings may be raised above the street elevation and accessed via a monumental
stair.
• They should respect the character of the fronting streets through the provision of a pedestrian-friendly
orientation including clear entrances from the street and permeable street walls with adequate windows (no
blank walls).
Planning Department
Morgan Square Pavilions – DRB Dec 3, 2024
DETERMINATION OF COMPLETENESS
Application is complete.
FIN
DINGS - EXCEPTIONS
• 6.4.4.a Minimize Blank Walls – Expanses of blank walls may not exceed 20 feet in length – Proposed blank wall along
Church Street is 24 ft for 2 of the 3 buildings
o Conditional Approval Recommended: See our notes in the Additional Comments section
• 6.4.4.c Transparency Zone – Glazing (transparent windows or doors) must extend at least 60% of the total façade width –
Proposed glazing along Church Street is less than 60% (measured at 21% of the total frontage of 61.5 ft for all three
buildings)
o Conditional Approval Recommended: See our notes in the Additional Comments section
CODE REVIEW
Exceptions or deviations required are noted in blue italics
A. Use Standards: The proposed use is permitted by right.
B. District Standards:
• 3.3.1 Lot Configuration: Compliant
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Not applicable
• 3.3.6 Building Frontage: Shopfront - permitted
C. General Standards:
• 4.1 Civic/Landmark Buildings:
• If indicated on the Downtown Master Plan, they must comply with the recommendations therein.
– Compliant
• They should be sited to terminate a street vista whenever possible and must incorporate
appropriate p
rominent features, designs, and entrances to celebrate a visual termination. –
Compliant
• They should incorporate detailing and materials that are authentic to the intended style. –
Compliant
• A pedestrian plaza, courtyard, or similar landscaped area may be substituted for a required
building frontage and minimum setback line. – Compliant
• Building entrances for civic buildings may be raised above the street elevation and accessed via a
monumental stair. – Compliant
• They should respect the character of the fronting streets through the provision of a pedestrian-
friendly orientation including clear entrances from the street and permeable street walls with
adequate windows (no blank walls). – Not Compliant on Church Street frontage but mitigated
with a substantial public art
component and three structures.
D. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space. Compliant
• 5.1.2 Corner Lots: Buildings located at street intersections must place the main build ing, or part of the
building, at the corner. Compliant
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian entrances
on a frontage line. Compliant
E. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliance presumed
• 5.2.2 Solid Waste Storage Areas: Compliance presumed
• 5.2.3 Mechanical and Utility Equipment: Compliant
F. Building Standards:
• 6.1.1 General Design Principles - Connectivity: Compliant with the exception of the blank wall that
creates a visual gap along the street frontage.
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Streetscapes should be composed of wide
sidewalks for walking, seating, public art, and landscaping. Exception required - see additional
comments
• 6.2 Required Building Design Standards:
o 6.2.1
Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant
• 6.4 Specific Building Design Standards for Mixed-Use and Commercial Buildings in D-T 5
o 6.4.1 Roof and Eaves: Compliant
o 6.4.2 Canopies/Awnings: Compliant
o 6.4.3 Encroachments: Compliant
o 6.4.4 Ground Level Detailing
a. Minimize Blank Walls: Expanses of blank walls may not exceed 20 feet in length. (A
“blank wall” is a facade that does not contain transparent windows or doors.) -
Exception required - see additional comments.
c. Transparency Zone: Glazing must extend from the corner of the front facade for a
depth equal to 60% of the length of the building Exception required - see additional
comments.
o 6.4.5 Materials: Compliant
G. Parking:
• Not Applicable
H. Streetscape and Site Landscaping:
• 8.1 Required Streetscape: 16 ft streetscape zone with a m inimum 16 ft sidewalk and trees planted in
wells consistent with downtown standards (40 ft on-center). Compliant
I. Signage: Not applicable.
ADD
ITIONAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
Blank Wall Condition along Church Street: There are three buildings proposed along the frontage of Church Street.
The southern-most building is proposed to be a “glass box” for a variety of special activity space needs. The
remaining two buildings are proposed to be more utilitarian in function – bathrooms and storage.
• While having inactive walls along a primary street is not ideal, the design takes measures to mitigate the
inactive frontage, by breaking up the massing into three distinct rotated structures.
• Also the design of each structure envisions a public art component with a highly textured wood slat system
that spells “Hub City”.
• Additionally, these utilitarian spaces are necessary in this location because of their proximity to the activity
lawn.
• The highly sculptured roof structure provides a unifying element that provides a further sense of visual
activity.
• The Church Street frontages will be further accentuated with decorative lighting and a seat wall component.
STAF
F RECOMMENDATION
Recommendation for Approval of the Morgan Square Plan.
Morgan Square Pavilions – DRB Dec 3, 2024
MORGAN SQUARE
12.03.2024
DRB PRELIMINARY REVIEW
OPPORTUNITIES
2
ENGAGEMENT MILESTONES
DICKENS OF A
CHRISTMAS
PUBLIC KICK-OFF
EVENT
STAKEHOLDER
ROUNDTABLES
COMMUNITY
WORKSHOP #1
FEBRUARY
15 MOBILE
WORKSHOPS
COMMUNITY
WORKSHOP #2
APRIL
ONLINE
ENGAGEMENT
VIA CITY WEBSITE
7 STEERING
COMMITTEE
MEETINGS
3
PERFECT DAY THEMES
“...activities for all -
especially live artists.”
“Love lights being hung
over the street”
“Lively concerts on
the square... Food vendors,
street musicians.”
“Shared, communal hang-out spot”
“...under the shade of a large
oak tree to stay cool...we hear
sounds of birds chirping.”
“... soak in the sun on the
grass...always a place to sit
and enjoy nature.”
“Spending time playing with
my daughter in the grass in
the middle of the Square.”
“It is sunny and nice. We
have a picnic on a blanket
(maybe a ‘Picnic restaurant’)
people watching.”
“...relax in comfortable chairs
while our kids freely play...”
“... order lunch outside
and sit in a shady area at a
table.”
“Historic buildings share the space
with dynamic new architecture....”
“...local vendors to browse...
a selection of small local
restaurants...options of
live music and shopping”
“After dinner we walk across the street
(Church) that has been slowed down ...”
“The ability to wander and go
from location to location. ”
“The space should be
safe for pedestrians...
walkable...European.”
GREEN!
PEDESTRIAN-FIRST
STREETS!
VIBRANT EDGES!
INVITING!
COMING
TOGETHER!
4
ALTERNATE CONCEPTS
ONE MORGAN SQUARE
CHURCH STREET
DUNBAR STREET
MAIN STREET
MAGNOLIA STREET
SPRING STREET
BROAD STREET
WALL STREET
Concept 1 - Knitting Into the Urban Fabric
ONE MORGAN SQUARE
CHURCH STREET
DUNBAR STREET
MAIN STREET
MAGNOLIA STREET
SPRING STREET
BROAD STREET
WALL STREET
CHURCH STREET
MAGNOLIA STREET
MAGNOLIA STREET
CHURCH STREET
ONE MORGAN SQUARE DUNBAR STREET
MAIN STREET
MAGNOLIA STREET
SPRING STREET
BROAD STREET
WALL STREET
MAGNOLIA STREET
Concept 3 - Hub City: Coming Together
Concept 2 - Celebrating the Landscape
5
INTERACTIVE ACTIVITIES
6
DESIGN DEVELOPMENT
MAIN STREET
DUNBAR STREET
Visitor Kiosk and Public Restrooms
Festival Street
Outdoor Dining Zone
Lounging Terraces
Performance Green
Water Feature
Dunbar Swings
Daniel Morgan Monument
Spartanburg Clock Tower
"I LOVE YOU" Sculpture
"Chaser" Sculpture
ILLUSTRATIVE PLAN
ONE MORGAN SQUARE
CHURCH STREET
SPRING STREET
WALL STREET
MAIN STREET
DUNBAR STREET
MAGNOLIA STREET
1
1
2
3
4
5
6
7
8
9
10
11
10
11
2
2
3
4
5
6
7
8
9
08.28.23
BIRDS EYE VIEW
GROUND LEVEL VIEW 1
GROUND LEVEL VIEW 2
ILLUSTRATIVE PLAN
Visitor Kiosk and Public Restrooms
Festival Street
Sidewalk and Outdoor Dining Zone
Lounging Terraces
Upper Green
Lower Green
Dunbar Swings
Daniel Morgan Monument
"I LOVE YOU" Sculpture
"Chaser" Sculpture
Garden Path
Gardens
Stone Eddys
ONE MORGAN SQUARE
MAIN STREET
DUNBAR STREET
1
1
2
3
4
5
6
7
8
9
10
11
12
13
10
12
12
12
11
11
13
13
9
3
2
2
4
5
6
Morgan Square Renovations Site Limits
7
7
8
CHURCH STREET
WALL STREET
MAGNOLIA STREET
N.. CHURCH STREET U.S. 221
SPRING STREET
MAGNOLIA STREET
WALL STREET
W. MAIN ST.
WALL STREET
N.. CHURCH STREET U.S. 221
W. MAIN ST.
N.. CHURCH STREET U.S. 221
MAGNOLIA STREET
N.. CHURCH STREET U.S. 221
L R
WH
PLANSCALE: 1"=20'
MORGAN SQUARE
0 20' 40'
N
10'
SITE LINEWORK
ONE MORGAN SQUARE
MAIN STREET
DUNBAR STREET
Morgan Square Renovations Site Limits
CHURCH STREET
WALL STREET
MAGNOLIA STREET
SPRING STREET
Visitor Kiosk and Public Restrooms
Festival Street
Sidewalk and Outdoor Dining Zone
Lounging Terraces
Upper Green
Lower Green
Dunbar Swings
Daniel Morgan Monument
"I LOVE YOU" Sculpture
"Chaser" Sculpture
Garden Path
Gardens
Stone Eddys
1
1
2
3
4
5
6
7
8
9
10
11
12
13
10
12
12
12
11
11
13
13
9
3
2
2
4
5
6
7
7
8
N.. CHURCH STREET U.S. 221
SPRING STREET
MAGNOLIA STREET
WALL STREET
W. MAIN ST.
WALL STREET
N.. CHURCH STREET U.S. 221
W. MAIN ST.
N.. CHURCH STREET U.S. 221
SPRING STREET
MAGNOLIA STREET
N.. CHURCH STREET U.S. 221
L R
WH
PLANSCALE: 1"=20'
MORGAN SQUARE
0 20' 40'
N
10'
LLLLL
LLLLLLLLLLLLLLLLLLLLLL
TREE PRESERVATION PLAN
ONE MORGAN SQUARE
MAIN STREET
DUNBAR STREET
Morgan Square Renovations Site Limits
Existing Trees to Preserve - 18
New Trees to be Planted - 30
CHURCH STREET
WALL STREET
MAGNOLIA STREET
Stone mounds for
seating
Granite Suppliers / Fabricators
ASL Stone
Polycor (local to North Carolina)
Cold Spring
Transition to monolithic
stone slab
Stone texture for added visual
interest and slip-resistance
TERRACES
Stone mounds for seating and play in
the form of eddys created by water
moving downhill
MAIN STREET
DUNBAR STREET
CHURCH STREET
Seat back angle varies for seating,
lounging, and reclining
TERRACES
DUNBAR STREET
CHURCH STREET
Vary heights to allow two sided
seating and spatial definition
TERRACES
Furnishings
CURVED BENCH SINGLE SEATS BENCH
LOUNGE CHAIR LOOSE TABLE AND CHAIR BEAN BAGS
PLNATERS RECYCLE BINS BOLLARD
STREET LIGHT GARDEN LIGHT
MANUFACTOR: MMCITE
PRODUCT: PARK BENCH WITH
BACKREST (LPC150-a; LPC150-e)
MATERIAL: ROBINIA
MANUFACTOR: MMCITE
PRODUCT: PARK BENCH WITH/WITHOUT
BACKREST (LPC152; LPC122)
MATERIAL: ROBINIA
DIMENSION: 19’’ WIDE
MANUFACTOR: MMCITE
PRODUCT: PARK BENCH WITH BACKREST (LPC150)
MATERIAL: ROBINIA
DIMENSIONS: 89’’ WIDE
MANUFACTOR: LUJO
PRODUCT: OUTDOOR BEAN BAG
KYOTO COLLECTION
MATERIAL:
DIMENSIONS: 36’’ X 44’’ X 48’’
COLOR: TBD
MANUFACTOR: STREETLIFE
PRODUCT: TUMBLING TUBS
MATERIAL: POWDER COATED STEEL
DIMENSIONS: 47’’/41’’ X 20’’HT
COLOR: TBD
MANUFACTOR: LANDSCAPE FORMS
PRODUCT: LAKESIDE LITTER
RECEPTACLES
MODEL: PLAIN TOP-OPENING
MATERIAL: POWDERCOATED STEEL
DIMENSIONS: 21’’DIA. X 36’’HT.
COLOR: TBD
MANUFACTOR: LANDSCAPE FORMS
PRODUCT: PARC CENTRE
COLLECTION: CHAIR NO ARM; 30’
ROUND TABLE
MATERIAL: POWDERCOAT
DIMENSIONS:
COLOR: TBD
MANUFACTOR: MMCITE
PRODUCT: ISAC
MODEL: SI 155
MATERIAL: POWDER COATED STEEL
DIMENSIONS: 5’’ DIA. X 34’’ HT
COLOR: TBD
MANUFACTOR: iGuzzini
PRODUCT: TWILIGHT BILBAO
DIMENSIONS: 12’ HT.
COLOR: TBD
MANUFACTOR: ARTEMIDE
PRODUCT: TOLOMEO OUTDOOR
MEGA HOOK SUSPENSION
MATERIAL:
DIMENSIONS:
COLOR: DOVE GRAY
MANUFACTOR: VESTRE
PRODUCT: BLOC SUN BENCH
MATERIAL: Accoya
COLOR: TBD
customed curved light
pole with hook for lamp
2.5''; 1.5''; 2'' Dia. light pole options
light pole options
different seating experience
on performance lawn
FURNISHINGS & LIGHTING
ONE MORGAN SQUARE
MAIN STREET
DUNBAR STREET
MAGNOLIA STREET
CHURCH STREET
N.. CHURCH STREET U.S. 221
SPRING STREET
MAGNOLIA STREET
WALL STREET
W. MAIN ST.
WALL STREET
MAGNOLIA STREET
L R
WH
PLANSCALE: 1"=20'
MORGAN SQUARE
0 20' 40'
N
10'
OUTDOOR DINING ZONES
MAIN STREET
DUNBAR STREET
6’ PEDESTRIAN ZONE
14’ DINING ZONE
2.5’ DINING ZONE
BOND STREET WINES
MEZCAL
BURGAR
THE SPICE & TEA EXCHANGE HUB CITY SPARTANBURGERS MONSOON NOODLE HOUSE UNDERPIN & INITIAL Q
THE FLYING BISCUIT CAFE DELANEY’S IRISH PUB
SMOKING BUTT HEADS BBQ
THE PALLADIAN BUILDING
INDEPENDENT CONSUMER FINANCE
MAGNOLIA STREET
MAGNOLIA STREET
MAGNOLIA STREET
MAGNOLIA STREET
Outdoor Dining Furniture
2019 - 18 tables
2024 - 108 tables
Proposed Dining Areas
385 sf
577 sf
319 sf
430 sf
489 sf
482 sf
395 sf
1,007 sf
491 sf
492 sf
723 sf
764 sf
A
D
G
J
B
E
H
K
L
C
F
I
A
B
C
D
E
F
G
H
I
J
K
L
Pavement Materials & Patterns
vary paver scale, texture and visual
interest in paving patterns
contrasting demarcation
lines for transition to
adjacent patterns
Pattern, texture and
color help define
sidewalk use areas and
neutralize varied facades
Pattern, texture and color
give each space its own
character
Weaving contrasting color into
patterns helps define spaces and
provides visual interest
MATERIALS
Sun/Shade Study
Mid April, 8am
Mid April, 10am
Mid April, noon
Mid April, 2pm
Mid April, 4pm
Mid April, 6pm
End of June, 8am
End of June, 10am
End of June, noon
End of June, 2pm
End of June, 4pm
End of June, 6pm
Mid- Sept., 8am
Mid- Sept., 10am
Mid- Sept., noon
Mid- Sept., 2pm
Mid- Sept., 4pm
Mid- Sept. , 6pm
Sun/Shade Study
Mid April, 8am
Mid April, 10am
Mid April, noon
Mid April, 2pm
Mid April, 4pm
Mid April, 6pm
End of June, 8am
End of June, 10am
End of June, noon
End of June, 2pm
End of June, 4pm
End of June, 6pm
Mid- Sept., 8am
Mid- Sept., 10am
Mid- Sept., noon
Mid- Sept., 2pm
Mid- Sept., 4pm
Mid- Sept. , 6pm
Sun/Shade Study
Mid April, 8am
Mid April, 10am
Mid April, noon
Mid April, 2pm
Mid April, 4pm
Mid April, 6pm
End of June, 8am
End of June, 10am
End of June, noon
End of June, 2pm
End of June, 4pm
End of June, 6pm
Mid- Sept., 8am
Mid- Sept., 10am
Mid- Sept., noon
Mid- Sept., 2pm
Mid- Sept., 4pm
Mid- Sept. , 6pm
SUN/SHADE STUDY
FULL SUN
Native plants for pollinators, butterflies, birds and beauty!
FULL SUN / PARTIAL SHADE FULL SHADE
Packera aurea
Golden Ragwort
Aronia melanocarpa 'Ground Hug'
Ground Hug Black Chokeberry
Amsonia 'Blue Ice'
Blue Ice Bluestar
Amsonia 'String Theory' PP34419
String Theory Bluestar
Aronia melanocarpa 'UCONNAM165'
Aronia Low Scape Mound
Itea virginica 'Sprich' Little Henry
Little Henry Virginia Sweetspire
Zizia aurea
Golden Alexander
Rhus aromatica 'Grow- Low'
Grow Low Fragrant Sumac
Heuchera villosa 'Autumn Bride'
Autumn Bride Heuchera
Fothergilla gardenii
Dwarf Fothergilla
Solidago shortii 'Solar Cascade'
Solar Cascade Goldenrod
Baptisia 'Lemon Meringue'
Lemon Meringue Baptisia
Amsonia hubrichtii
Blue Star
Amsonia tabernamontana var. salicifolia
Willow- Leaved Bluestar
Echinacea purpurea 'Fragrant Angel'
Fragrant Angel Coneflower
Hydrangea quercifolia 'Sikes Dwarf'
Sikes Dwarf Oakleaf Hydrangea
Ageratina altissima
White Snakeroot
Clethra alnifolia 'Hummingbird'
Hummingbird Sweet Pepperbush
Viburnum obovatum 'Raulston Hardy'
Raulston Hardy Viburnum
Itea virginica "Henry's Garnet'
Henry's Garnet Virginia Sweetspire
Hydrangea quercifolia 'Pee Wee'
Pee Wee Oakleaf Hydrangea
Ilex glabra 'Shamrock'
Shamrock Inkberry
Fothergilla milleri 'Redneck Nation'
Redneck Nation Fothergilla
'
Chasmanthium latifolium
River Oats
Hydrangea quercifolia
Oakleaf Hydrangea
Hydrangea arborescens 'Bounty'
Bounty Wild Hydrangea
Clethra alnifolia
Summersweet
Ilex glabra
Inkberry
Aronia arbutifolia
Chokeberry
Claycanthus floridus
Sweetshrub
Morella cerifera
Southern Wax Myrtle
Ilex vomitoria
Youpon Holly
Chinonanthus virginicus
Fringe Tree
Chrysogonum virginianum
Goldenstar (Green and Gold)
Carex Pennsylvanica
Pennsylvania Sedge
Carex laxiculmis 'Hobb' Bunny Blue
Blue Bunny Sedge
Pachysandra procumbens
Allegheny Spurge
Carex flacca 'Blue Zinger'
Seersucker Sedge
Dryopteris marginalis
Leather Wood Fern
Eurybia divaricata
White Wood Aster
Maianthemum racemosum
False Solomon's Seal
Dryopteris ludoviciana
Southern Wood Fern
Illicium parvifolium 'Florida Sunshine'
Florida Sunshine Anise
Lindera benzoin
Spicebush
Chrysogonum virginianum
Goldenstar (Green and Gold)
Carex Pennsylvanica
Pennsylvania Sedge
Carex laxiculmis 'Hobb' Bunny Blue
Blue Bunny Sedge
Pachysandra procumbens
Allegheny Spurge
Carex flacca 'Blue Zinger'
Seersucker Sedge
Dryopteris marginalis
Leather Wood Fern
Eurybia divaricata
White Wood Aster
Maianthemum racemosum
False Solomon's Seal
Dryopteris ludoviciana
Southern Wood Fern
Illicium parvifolium 'Florida Sunshine'
Florida Sunshine Anise
Lindera benzoin
Spicebush
Phlox subulata 'Snowflake'
Snowflake Creeping Phlox
Phlox subulata 'Purple Beauty'
Purple Beauty Creeping Phlox
Coreopsis verticillata 'Zagreb'
Threadleaf Coreopsis
Achillea millefolium 'Moonshine'
Moonshine Yarrow
Achillea 'Hella Glasshoff'
Hella Glasshoff Yarrow
Carex woodii
wood's sedge
Asclepias tuberosa
Butterfly Weed
Itea virginica 'SMNIVMM'
Fizzy Mizzy Virginia Sweetspire
schizachyrium scoparium 'Carousel'
Little bluestem
Rudbeckia fulgida
Black Eye Susan
Rudbeckia- x- American- Gold- Rush
American Gold rush black eyed susan
Coreopsis palustris 'Summer Sunshine'
Summer Sunshine Coreopsis
vernonia lettermannii 'Iron Butterfly'
Iron Butterfly Ironweed
Solidago rugosa 'Fireworks'
Fireworks Goldenrod
Solidago 'Wichita Mountains'
Wichita Mountains Goldenrod
Rudbeckia subtomentosa 'Henry Eilers'
Sweet Coneflower
PLANT PALETTE
Storage Building for
Events and Programming
Restrooms and Drinking
Fountain
Visitor Kiosk
PAVILION PLAN
ONE MORGAN SQUARE
DUNBAR STREET
CHURCH STREET
PAVILION
Visitor Kiosk
Restrooms Storage for Events and
Cafe Tables
PAVILION
PAVILION
PAVILION
COPPER CANOPY ROOF SHINGLES
EXTERIOR PAINTED FIBER CEMENT
OPERABLE GLASS DOORS
EXTERIOR METAL WALL PANEL
STAINED PRESSURE TREATED WOOD CEILING
STEEL/WOOD STRUCTURAL COLUMNS
EXTERIOR VERTICAL WOOD SCREEN
STRUCTURAL SILICONE GLAZING
PAVILION MATERIALS
EVENTS & PROGRAMMING
MAIN STREET
DUNBAR STREET
ONE MORGAN SQUARE
MAGNOLIA STREET
CHURCH STREET
EVENTS & PROGRAMMING
Plaza 17,759 Sq. Ft.
Standing: 2,000 - 2,100 people
Seating: 1,000 - 1,100 people
Blankets: 800 - 900 people
Lower Lawn 4,317 Sq. Ft.
Standing: 450 - 550 people
Seating: 300 - 400 people
Blankets: 150 - 250 people
Upper Lawn 8,675 Sq. Ft.
Standing: 950 - 1,050 people
Seating: 650 - 750 people
Blankets: 350 - 450 people
THANK YOU!
PO Box 1749 • S
partanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org
website: www.cityofspartanburg.org
ADDRESS/ TAX ID
203 Freemont Avenue/Danbury Commons
TO
Spartanburg Design Review Board
DATE
11/26/2024
PROJECT NUMBER
DRB-24-020-00017
COPIES TO
City
Departments
Applicant
STAFF
Fredalyn M. Frasier, Planning Director
Nan Zhou, AICP, Planner II
Craig Lewis, FAICP – Technical Advisor
OWNER/APPLICANT
Owner: Dialysis Clinic Inc / Applicant: Field Goodlett, Connelly Development, LLC.
GENERAL PROJECT OVERVIEW
The 1.96 acre site is bound by Fremont Avenue to the north and is surrounded primarily by one and two-story detached
house and is immediately adjacent to a single -story, four-unit apartment building to the west. There is an existing
single-story, commercial building on the site with a small parking lot to the rear.
The pro
posed 48-unit, four story multi-family building will include parking to the rear and a new detention pond.
AUTHORIT
Y & APPLICABILITY
The proposed project in located in the DT-4 zone. Formal design review and approval by the Design Review Board is
required.
DETERMINATION OF COMPLETENESS
Application is complete.
FINDING
S - EXCEPTIONS
• No exceptions expected.
CODE REVIEW
Exc
eptions or deviations required are noted in blue italics
A. Use Standards: The proposed use (multi-family) is permitted by right.
B. District Standards:
• 3.3.1 Lot Configuration: Complia nt
• 3.3.2 Primary Building Standards: Compliant
• 3.3.4 Building Height: Compliant
• 3.3.5 Permitted Parking Location: Compliant
• 3.3.6 Building Frontage: Common Lawn – permit ted
Planning Department
C. Lot/Site Standards:
• 5.1.1 Lot Frontage: All lots must front on a street, square, or common open space. Compliant
• 5.1.2 Corner Lots: Buildings located at street intersections must place the main building, or part of the
building, at the corner. Compliant
• 5.1.3 Pedestrian Entries from Frontage Line: Buildings must have their principal pedestrian entrances on
a frontage line. Compliant
• 5.1.4 Setbacks: Front and side setbacks must be consistent with those of surrounding buildings.
Compliant
CI. Utilities and Trash Containment:
• 5.2.1 Underground Utilities: Compliance Presumed – to be confirmed prior for Final Approval
• 5.2.2 Solid Waste Storage Areas: Compliant
• 5.2.3 Mechanical and Utility Equipment: Compliant
CII. Building Standards:
• 6.1.1 General Design Principles - Connectivity: Compliant
• 6.1.1 General Design Principles - Downtown Should be Urban: Compliant
• 6.1.5 General Design Principles - Put People First: Compliant
• 6.2 Required Building Design Standards:
o 6.2.1 Architectural Style: Compliant
o 6.2.2 Compatibility: Compliant
o 6.2.3 Proportions: Compliant
o 6.2.4 Wall Materials: Compliant
o 6.2.5 Façade Treatment: Compliant
o 6.2.6 Building Entrances: Compliant
• 6.3 Specific Building Design Standards for Mixed-Use and Commercial Buildings in D-T5
o 6.3.1 Roof and Eaves: Compliant
o 6.3.2 Façade Design: Compliant
o 6.3.3 Building Entrances: Compliance Presumed
o 6.3.4 Garages: Not Applicable
o 6.3.5 Materials: Compliant
CIII. Parking:
• 7.1.4 Parking Area Access: Compliant
• 7.2 Bicycle Parking: Compliance Presumed – to be confirmed prior for Final Approval
CIV. Streetscape and Site Landscaping:
• 8.1 Required Streetscape: 11 ft streetscape zone with a minimum 5 ft sidewalk and street trees in a 6 ft
wide planting strip. Compliant
CV. Signage: The applicant is required by the State of SC to install signage. Applicant to provide signage detail and
placement for Final Revie w Approval.
ADDITIO
NAL COMMENTS AND SUGGESTIONS FOR BOARD CONSIDERATION
• None
STAFF RECOM
MENDATION
Preliminary approval recommended.
203 Fremont Avenue, Spartanburg, SC
Zoning Map – 203 Fremont Ave.
203 Fremont Avenue, Spartanburg, SC
North East View of Site along
Fremont Avenue
Interior view looking at
Fremont Avenue
212 Fremont
204 Fremont
194 Fremont
North West corner of
site, view of Chapel
street park
Southwest view of site
Sreetview down freemont
looking south west
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
225 ROCKY CREEK ROAD, GREENVILLE, SC 29615
PH: (864)271-0496
www.sitedesign-inc.com
Know what's below.
Call before you dig.
Know what's below.Call before you dig.
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
PH: (864) 285-0618
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
DANBURY COMMONS
MULTI-FAMILY
S.C. REG 23536
C100
EXISTING CONDITIONS
AND DEMOLITION
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
CONNELLY
DEVELOPMENT, LLC
DEMOLITION NOTES
1. DEMOLITION AND REMOVAL IS NOT NECESSARILY LIMITED TO THE ITEMS SHOWN
ON THIS PLAN. CONTRACTOR SHALL REMOVE ADDITIONAL EXISTING UNSUITABLE
MATERIAL OR STRUCTURES WITHIN THE CONSTRUCTION AREA AS NECESSARY.
2. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF UNDERGROUND
STORAGE TANKS OR OTHER EQUIPMENT IS UNEARTHED OR OTHERWISE
DISCOVERED.
3. ALL EXISTING UTILITY DEMOLITION, REMOVAL, OR ABANDONMENT (WATER,
SEWER, STORM DRAINAGE, ELECTRIC, GAS, TELEPHONE, CABLE, ETC.) SHALL BE
DONE IN ACCORDANCE WITH THE STANDARDS, RULES, REGULATIONS, AND
REQUIREMENTS OF THE APPLICABLE GOVERNING UTILITY ENTITY. CONTRACTOR
SHALL COORDINATE UTILITY WORK WITH THE APPROPRIATE UTILITY ENTITY.
CONTRACTOR TO VERIFY USEFULNESS OF EXISTING SITE UTILITIES WITH THE
APPROPRIATE UTILITY ENTITY.
4. THE CONTRACTOR SHALL OBTAIN ALL PERMITS FROM CITY OF SPARTANBURG
NECESSARY OR REQUIRED TO PERFORM DEMOLITION. THE CONTRACTOR IS
RESPONSIBLE FOR THE PROPER DISPOSAL OF DEMOLITION DEBRIS.
5. THE CONTRACTOR SHALL CONDUCT ALL DEMOLITION, REMOVAL, STORAGE,
CLEANUP, ETC. IN ACCORDANCE WITH ALL REGULATING AUTHORITIES INCLUDING
BUT NOT LIMITED TO CITY OF SPARTANBURG, SCDHEC, AND THE U.S.
ENVIRONMENTAL PROTECTION AGENCY.
6. NO WORK MAY BE PERFORMED WITHIN THE STATE RIGHT-OF-WAY WITHOUT AN
APPROVED SCDOT ENCROACHMENT PERMIT.
7. EVERY ATTEMPT TO RECYCLE DEMOLISHED MATERIALS SHOULD BE MADE.
COORDINATE WITH ON-SITE CONSTRUCTION MATERIALS TESTING FIRM TO
IDENTIFY ANY MATERIAL TO BE RECYCLED.
8. ALL EXISTING DRIVEWAYS AND CURB CUTS THAT ARE NOT USED SHALL BE
REMOVED AND REPLACED WITH A CONCRETE CURB, GUTTER, AND/OR SIDEWALK
(IF EXISTING).
9. SAWCUT EDGE OF ALL PAVEMENT TYPES WHERE CONNECTIONS ARE TO BE MADE.
IF ASPHALT IS DAMAGED AT POINT OF CONNECTION, A PATCH WILL BE REQUIRED
BY MILLING 2" DEPTH AT A MINIMUM WIDTH OF 6.5' FOR THE ENTIRE LENGTH OF
THE DAMAGED SECTION. IF ADJACENT SIDEWALK IS DAMAGED AT CONNECTION,
THEN THAT SECTION WILL BE REMOVED AND REPLACED FROM JOINT TO JOINT.
ZONING: DT-4
COORDINATE REMOVAL
OF EXISTING LIGHT AND
POWER W/ DUKE ENERGY
REMOVE EXISTING
CHAIN LINK FENCE
REMOVE EXISTING
CURBING ALONG
SITE FRONTAGE
REMOVE EXISTING
CURBING WITHIN SITE
LIMITS
EXISTING GAS SERVICE -
COORDINATE REMOVAL
OF SERVICE WITH
PIEDMONT NATURAL GAS
DEMO SIDEWALK TO
EXTENTS SHOWN
CONTRACTOR TO SUBMIT
PEDESTRIAN TRAFFIC
CONTROL PLAN TO CITY
WITH ENCROACHMENT
PERMIT
287.5' LIMITS OF CURB AND
SIDEWALK DEMOLITION
EXISTING FIRE SERVICE TO BE
MAINTAINED AND PROTECTED FOR
FUTURE USE - CONTRACTOR TO
COORDINATE RE-ROUTE OF FIRE
SERVICE WITH SPARTANBURG
WATER CROSS CONNECTIONS
EXISTING 2" METER TO
REMAIN AS FUTURE
DOMESTIC METER
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
EXISTING CATCH
BASIN TO BE
REMOVED
EXISTING DROP INLET
TO REMAIN - CONVERT
TO MANHOLE
EXISTING
DRAIN PIPE TO
BE REMOVED
COORDINATE REMOVAL
OF EXISTING UTILITY
POLE WITH DUKE
ENERGY
COORDINATE REMOVAL
OF EXISTING UTILITY
POLE WITH DUKE
ENERGY
± 15,000 S.F. OF BUILDING
DEMOLITION
± 30,000 S.F. OF
PAVEMENT REMOVAL
REMOVE EXISTING
CHAIN LINK FENCE
REMOVE EXISTING
CHAIN LINK FENCE
REMOVE EXISTING
CHAIN LINK FENCE
REMOVE EXISTING
CHAIN LINK FENCE
SCREENING WALL TO
REMAIN IF CONDITION
ALLOWS
UTILITY
POLE TO
REMAIN UTILITY
POLE TO
REMAIN
UTILITY
POLE TO
REMAIN
EXISTING FIRE
HYDRANT
UTILITY
POLE TO
REMAIN
APPROXIMATE
LOCATION OF 6" FIRE
SERVICE CONNECTION
- CONTRACTOR TO
VERIFY
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
PH: (864) 285-0618
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
DANBURY COMMONS
MULTI-FAMILY
S.C. REG 23536
C200
SITE PLAN
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
CONNELLY
DEVELOPMENT, LLC
Know what's below.Call before you dig.
SITE NOTES:
1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES
BY CALLING UTILITY LOCATION SERVICE AT 811 THREE (3) DAYS PRIOR TO
CONSTRUCTION.
2. DIMENSIONS SHOWN ARE TO FACE OF CURB, CENTERLINE OF PARKING STALL OR
FACE OF BUILDING UNLESS OTHERWISE NOTED.
3. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND
ENTRY/EXIT PORCHES.
4. ASPHALT PAVING SECTIONS SHALL BE CONSTRUCTED PER THE DETAILS.
5. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED WITH 3000 PSI CONCRETE 4" THICK
WITH EXPANSION JOINTS AND SCORING PER DETAIL.
6. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST
REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
7. ALL WORK ON STATE, COUNTY, OR CITY RIGHT-OF-WAY INCLUDING DRIVEWAY
APRONS, WATER AND SEWER TAPS OR ANY OTHER WORK REQUIRES AN
ENCROACHMENT PERMIT FROM THE APPROPRIATE AGENCY.
8. ALL CURBING TO BE 18" FORMED CONCRETE CURBING PER DETAIL, WITH 3000 PSI
CONCRETE.
9. ANY MATERIAL DEMOLISHED AS INDICATED ON THIS PLAN IS TO BE HAULED OFF-SITE
TO AN APPROVED LANDFILL.
10. TRUNCATED DOMES ARE TYPICAL AT ALL HANDICAP RAMPS. HANDICAP SPACES
WILL BE MARKED WITH A FREESTANDING OR WALL MOUNTED SIGN. SEE DETAIL
SHEETS FOR PROPER STRIPING.
PARKING DATA:
1.4 SPACES PER UNIT -
48 UNITS @ 1.4 SPACES PER UNIT = 67 SPACES
REGULAR SPACES PROVIDED: 61 SPACES
HC SPACES PROVIDED: 7 SPACES
TOTAL PROVIDED: 68 SPACES
KEYED NOTES
18" CONCRETE CURB AND GUTTER
ASPHALT PAVING (SEE LEGEND FOR TYPE)
CONCRETE PAVING
SUTERA UNDERGROUND TRASH AND
RECYCLING SYSTEM
STOP SIGN & 24" STOP BAR
3' CONCRETE FLUME WITH TYPE 16 CURB INLET
IN SIDEWALK
WHEEL STOP (TYP.)
ADA PARKING SPACE & ACCESS AISLES 1-1/2%
(2% MAX) SLOPE IN ALL DIRECTIONS (TYP.)
HANDICAP SIGN (TYP.)
ADA RAMP W/ DETECTABLE WARNING
SURFACE (TYP.)
4" PAINTED STRIPE
5' WIDE CONCRETE SIDEWALK
MECHANICAL UNITS (REFER TO LANDSCAPING
FOR SCREENING)
SIDEWALK DRAINAGE PLATE
STRIPED PATH (4" PAINTED STRIPE)
4' HIGH BLACK VINYL COATED CHAIN LINK
FENCE WITH 4' WIDE DOUBLE SWING GATE
42" TALL SITE WALL WITH SAFETY RAILING
(DESIGN BY OTHERS)
EXISTING FIRE SERVICE VAULT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
PAVEMENT LEGEND
LIGHT DUTY ASPHALT
HEAVY DUTY ASPHALT
SITE DATA
SITE ADDRESS 203 FREMONT AVENUE
SPARTANBURG, SC 29303
OWNER/DEVELOPER CONNELLY DEVELOPMENT, INC.
125 OLD CHAPIN ROAD
LEXINGTON, SC 29072
CONTACT: LAURA NICHOLSON
(803) 798-0572
LDN@CONNELLYBUILDERS.COM
CIVIL ENGINEER SITE DESIGN, INC.
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
ARCHITECT PARKS-PLAYER
85 CLEVELAND ST. SUITE 201
GREENVILLE, SC 29601
(864) 382-5000
ZONING DT-4
DOWNTOWN 4
PROPOSED USE MULTI-FAMILY
TAX MAP # TMS# 7-12-01-080.00
PARCEL AREA 1.88 ACRES
SETBACKS FRONT: 6' (MIN.) 18' (MAX)
SIDES: 0'
REAR: 3'
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
18.0'
9.0'
9.0'
18.0'
9.0'
14.0'
9.0'
18.0'
9.0'
9.0'
18.0'
24.0'
24.0'
24.0'
24.0'
24.0'
5.0'
R5.0'
R25.0'
R62.0' R38.0'
R62.0' R38.0'
R3.0'
R15.0'
R3.0'
R9.0'
R10.0'
R3.0'
R25.0'
R6.0'
R25.0'
R3.0'
R20.0'
R6.0'
R3.0'
R3.0'
R3.0'
1
2
3
3
3
4
5
6
6
6
1
1
1
7
8
9 13
10
11
12
14
15
16
1617
6
10
10
8
R25.0'
R6.0'
R20.0'
CONCRETE PAVEMENT/SIDEWALK
DETENTION
POND
14
14
15
COVERED DROPOFF
- REFER TO
ARCHITECTURAL
DRAWINGS
18
1
6.0' PLANTING
STRIP
12 5.0'
11.0' STREETSCAPE
6' SETBACK
PAINT 1
FIBER CEMENT PANEL
SIDING
SHERWIN WILLIAMS
SNOWBOUND SW 7004
P1
PAINT 3
BALCONY FIBER CEMENT
SIDING BODY, ALL TRIM
BANDS & COLUMNS,
WINDOW & DOOR TRIM
WHITE
P3
PAINT 4
ALL METAL DETAILS,
GUARDRAILS
BLACK
PAINT 5
METAL AWNINGS
BLACK
P5
DOWNSPOUTS
WHITE
D1
WINDOWS
WHITE
W1
DOORS
BLACK
PAINT 6
P6
PAINT 2
FIBER CEMENT
HORIZONTAL SIDING
SHERWIN WILLIAMS
DOVETAIL SW 7018
P2
PAINT 7
P7
BRACKETS
BLACK
ROOF SHINGLES
BLACK
P4R1
P1P1P5P4P4 W1P1 P6 P7R1P2P3 D1R1 R1R1 P6 P6P6 P6P1 P2 P2P2P2 W1W1P5 P5 P5P7 P3 P4B1
BRICK
TRIANGLE LIBBY MILL
B1
MATERIAL BOARD - FREEMONT AVENUE ELEVATION
DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.01.24
24-07
1
FRONT ELEVATION
1/8" = 1'-0"
CEMENT FIBER OR
VINYL CORNER &
WINDOW TRIM - TYP
VINYL OR FIBER
CEMENT PERFORATED
SOFFIT - TYP
ANTI-FUNGAL DIM. ARCH.
SHINGLES W/ MIN. 30-YR
WARRANTY - TYP
BRICK - TYPFIBER CEMENT
HORIZONTAL SIDING - TYP
FIN. FLOOR
TOP PLATE
8'-1 1/2"
2nd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
3rd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
4th FLOOR1'-6 3/4"
TRUSS BRIDGE
8'-1 1/2"
12
7
12
4
FIBER CEMENT
PANEL - TYP
FIBER CEMENT
PANEL - TYP
12
7
FIBER CEMENT
PANEL - TYP
NOTE: SEE A-6 FOR EXTERIOR HVAC UNIT LOCATIONS
METAL OR ARCH. SHINGLE ROOF
2
FREEMONT AVE ELEVATION
1/8" = 1'-0"
METAL ROOF - TYP
FIN. FLOOR
TOP PLATE
8'-1 1/2"
2nd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
3rd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
4th FLOOR1'-6 3/4"
TRUSS BRIDGE
8'-1 1/2"
12
7
12
7
12
7
FIBER CEMENT
PANEL - TYP
BRICK - TYPFIBER CEMENT
HORIZONTAL SIDING - TYP
FIBER CEMENT
PANEL - TYPVINYL RAILING - TYPFIBER CEMENT TRIM
WRAPPED COLUMNS - TYP
FREEMONT AVE ELEVATION TRANSPARENCY - 21%
CORP. SEAL
SEAL
BUILDING
ELEVATIONS
A-10.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
1
RIGHT SIDE ELEVATION
1/8" = 1'-0"
12
5
FIN. FLOOR
TOP PLATE
8'-1 1/2"
2nd FLOOR
1'-6 3/4"
TOP PLATE
8'-1 1/2"
3rd FLOOR
1'-6 3/4"
TOP PLATE
8'-1 1/2"
4th FLOOR
1'-6 3/4"
TRUSS BRIDGE
8'-1 1/2"
12
4
12
4
FIBER CEMENT
PANEL - TYP
BRICK - TYPFIBER CEMENT
HORIZONTAL SIDING - TYP
ELECTRICAL
METER BANK
FREEMONT AVE ELEVATION TRANSPARENCY - 12%
FIN. FLOOR
TOP PLATE
8'-1 1/2"
2nd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
3rd FLOOR1'-6 3/4"
TOP PLATE
8'-1 1/2"
4th FLOOR1'-6 3/4"
TRUSS BRIDGE
8'-1 1/2"
12
5
2
LEFT SIDE ELEVATION
1/8" = 1'-0"
12
4
12
4
FIBER CEMENT
PANEL - TYP
BRICK - TYP FIBER CEMENT
HORIZONTAL SIDING - TYP
ELECTRICAL
METER BANK
SPRINKLER
CLOSET
3
ROOF PLAN
1/16" = 1'-0"
7:12
5:12
7:12
7:12
7:12
7:12
5:12
5:12
5:125:12
4:124:12
7:12 7:12
5:12
4:12 4:12
4:12 4:12
4:12 4:12
4:12 4:12
7:12
5:12
7:12
7:12
5:12
5:125:12
TYPICAL EACH HIP ROOF
METAL OR ARCH
SHINGLE ROOF
METAL ROOF
CORP. SEAL
SEAL
BUILDING
ELEVATIONS
& ROOF PLAN
A-11.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
1
1ST FLOOR PLAN
1/8" = 1'-0"
2 BEDROOM
UNIT
DECK
1 BEDROOM
UNIT 2 BEDROOM
UNIT
2 BEDROOM
HC UNIT 2 BEDROOM
UNIT
DECK
2 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
HC UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT 1 BEDROOM
UNIT
ELEV.
FILE /
STORAGE
OFFICE
203 SF
ENTRY
ENTRY
STAIR STAIR
240'-6"
80'-6"
CORRIDOR CORRIDOR
30'-2 3/8"
COVERED
DRIVE
THRU
3'-4 1/2"
10'-2"
1"
28'-0"
1"
37'-0"
1"
37'-0"
1"
36'-10"
1"
37'-0"
1"
37'-0"
1"
10'-2" 3'-4 1/2"
10'-11"29'-1"32'-6"
240'-6"
37'-0"
1"
28'-0"
1"
37'-0"
1"
28'-0" 8'-1" 28'-0" 37'-0"
1"
37'-0"
80'-6"
9'-11"29'-1"32'-6"
1"
7'-0"
8'-0"
6'-6"
25'-2 1/2"
1'-0"
1'-0"
SCREENED
HVAC - TYP.
COVERED
PORCH
8'-0"
9'-8"
13'-0"
11'-4"
13'-0"
15'-11"7'-4"
STORAGE
AV
MGR
OFFICE
COVERED
SEATING
13'-0"
5'-6 1/2"
MAIL
CORP. SEAL
SEAL
1ST FLOOR
PLAN
A-6.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
1
2ND FLOOR PLAN
1/8" = 1'-0"
2 BEDROOM
HEARING
AND SITE
UNIT
DECK
1 BEDROOM
UNIT 2 BEDROOM
UNIT
2 BEDROOM
HC UNIT 2 BEDROOM
UNIT
DECK
2 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT 1 BEDROOM
UNIT
AV
ELEV.
MULTI-PURPOSE
ROOM
571 SF
MAINT.
ROOM
STAIR STAIR
CORRIDOR CORRIDOR
240'-6"
80'-6"
3'-4 1/2"
10'-2"
1"
28'-0"
1"
37'-0"
1"
37'-0"
1"
36'-10"
1"
37'-0"
1"
37'-0"
1"
10'-2" 3'-4 1/2"
10'-11"29'-1"32'-6"
240'-6"
37'-0"
1"
28'-0"
1"
37'-0"
1"
28'-0" 8'-1" 28'-0" 37'-0"
1"
37'-0"
80'-6"
9'-11"29'-1"32'-6"
1"
6'-6"
1'-0"
1'-0"
6'-0"
COVERED
PORCH
ROOF BELOW
COMPUTER
196 SF
9'-8 1/2"
5'-6 1/2"
7'-0"
8'-0"
CORP. SEAL
SEAL
2ND FLOOR
PLAN
A-7.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
1
3RD FLOOR PLAN
1/8" = 1'-0"
2 BEDROOM
UNIT
1 BEDROOM
UNIT 2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT 1 BEDROOM
UNIT
ELEV.
EXERCISE
ROOM
UTL /
STOR
STAIR STAIR
LAUNDRY
CORRIDOR CORRIDOR
240'-6"
73'-6"
3'-4 1/2"
10'-2"
1"
28'-0"
1"
37'-0"
1"
37'-0"
1"
36'-10"
1"
37'-0"
1"
37'-0"
1"
10'-2" 3'-4 1/2"
10'-11"29'-1"32'-6"
240'-6"
37'-0"
1"
28'-0"
1"
37'-0"
1"
28'-0" 8'-1" 28'-0" 37'-0"
1"
37'-0"
72'-6"
9'-11"29'-1"32'-6"
1"
1'-0"
1'-0"
23'-0 1/2"
9'-11"
AV
196 SF
12'-11"
9'-8 1/2"
5'-6 1/2"
CORP. SEAL
SEAL
3RD FLOOR
PLAN
A-8.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
1
4TH FLOOR PLAN
1/8" = 1'-0"
2 BEDROOM
UNIT
1 BEDROOM
UNIT 2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT1 BEDROOM
UNIT
2 BEDROOM
UNIT 1 BEDROOM
UNIT
AV
ELEV.
UTL /
STOR
STAIR STAIR
SITTING /
LIBRARY
CORRIDOR CORRIDOR
240'-6"
73'-6"
3'-4 1/2"
10'-2"
1"
28'-0"
1"
37'-0"
1"
37'-0"
1"
36'-10"
1"
37'-0"
1"
37'-0"
1"
10'-2" 3'-4 1/2"
10'-11"29'-1"32'-6"
240'-6"
37'-0"
1"
28'-0"
1"
37'-0"
1"
28'-0" 8'-1" 28'-0" 37'-0"
1"
37'-0"
72'-6"
9'-11"29'-1"32'-6"
1"
1'-0"
1'-0"
10'-2 1/2"
9'-2 1/2"
14'-0"
15'-6 1/2"
9'-8 1/2"
5'-6 1/2"
CORP. SEAL
SEAL
4TH FLOOR
PLAN
A-9.00 DANBURY COMMONS
APARTMENTS
SPARTANBURG, SOUTH CAROLINA
THIS DRAWING IS THE PROPERTY OF PARKS-PLAYER ARCHITECTURE & PLANNING, LLC AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT IS ONLY TO BE USED FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT TO BE USED ON ANY OTHER PROJECT. IT IS TO BE RETURNED UPON REQUEST.
Sheet Number:
DateDescription No.
85 CLEVELAND ST., SUITE 201
GREENVILLE, SC. 29601
(864) 382-5000
PARKS-PLAYER
ARCHITECTURE
& PLANNING, LLC
File Reference:
Job Number:
Scale:
5 4 3 2 1
A
B
C
11.07.24
24-07
(826)
(826)
(827)
(828)
(829)
(830)
(830)(829)
(828)
(827)
(826)
(825)
(830)
(830)
(829)
(828)
(827)
(830)
(831)
(832)
(832)
(831)
(830)
(835)
(832)
(833)
(834)
(835)
(832)
(833)
(834)
(831)
(831)
(831)
(831)
(835)
(834)
(836)
(826)
(827)
(828)
(826) (827) (828) (829)
24LF-18"RCP @ 0.82%
89LF-18"RCP @ 0.68%
HW - 1
IE: 825.40
HW - 2
IE: 826.00
DI - 1
TYPE 'A' INLET
RIM EL.: 831.00
IE IN: 827.00
IE OUT: 827.00
OCS - 1
IE: 825.00
EX. DI 1
MANHOLE
RIM EL.: 826.46
IE IN: 822.22
IE OUT: 821.40
15LF-18"RCP @ 0.98%
CB - 2
TYPE 'B' INLET
RIM EL.: 830.16
IE IN: 826.40
IE OUT: 826.40
HW - 3
IE: 826.25
CB - 1
TYPE 'B'
RIM EL.: 830.29
IE IN: 825.60
IE OUT: 825.60
73LF-18"RCP @ 0.55%
FF ELEV:
833.25
CB - 3
TYPE 'B' INLET
RIM EL.: 832.02
IE IN: 827.75
IE OUT: 827.25
DI - 2
TYPE 'A' INLET
RIM EL.: 831.50
IE OUT: 828.39
68LF-12"RCP @ 0.94%
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
PH: (864) 285-0618
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
DANBURY COMMONS
MULTI-FAMILY
S.C. REG 23536
C400
GRADING AND
STORMWATER PLAN
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
CONNELLY
DEVELOPMENT, LLC
Know what's below.Call before you dig.
GRADING NOTES:
1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES BY
CALLING UTILITY LOCATION SERVICE AT 811 THREE (3) DAYS PRIOR TO CONSTRUCTION.
2. THE CONTRACTOR SHALL NOTIFY THE ENGINEER FOR A REVIEW SHOULD ANY
DISCREPANCIES BE DISCOVERED AT THE SITE OR ON THE DRAWINGS.
3. PROOFROLLING AND COMPACTION TESTS SHALL BE ACCOMPLISHED IN THE FIELD TO
TEST FILLED AREAS. INITIAL COMPACTION TESTS WILL BE CONDUCTED AT OWNER'S
EXPENSE. RETESTING REQUIRED BECAUSE OF POOR COMPACTION SHALL BE
CONDUCTED AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL SUPPLY RESULTS TO
THE ENGINEER BEFORE ANY PRELIMINARY AND/OR FINAL APPROVALS.
4. THE GRADING CONTRACTOR SHALL PROOFROLL THE CONSTRUCTION AREA WITH HEAVY
RUBBER-TIRED EQUIPMENT. ALL SOFT SPOTS SHALL BE STABILIZED BY FURTHER
COMPACTIVE EFFORT OR UNDERCUT AND BACKFILLED WITH COMPACTED STRUCTURAL
FILL MATERIAL.
5. EARTHWORK SHALL BE TO THE GRADES AND LINES SHOWN. EXISTING AND PROPOSED
CONTOUR INTERVALS ARE AT 1'.
6. ALL NEW ELEVATIONS SHOWN ARE FINISH ELEVATIONS. THE GRADING CONTRACTOR
SHALL DEDUCT THE APPROPRIATE AMOUNT TO ESTABLISH SUBGRADE ELEVATION.
7. WALL ELEVATIONS WHERE NOTED ARE TOP OF WALL AND FINISH GRADE AT BOTTOM OF
WALL. SEE RETAINING WALL PLANS FOR DETAILED CONSTRUCTION INFORMATION.
8. CONTRACTOR SHALL REMOVE TOPSOIL AS NECESSARY (MINIMUM OF 4") TO PROVIDE
ADEQUATE SUBGRADE FOR ROADWAYS.
9. ALL EXCAVATION SHALL BE "UNCLASSIFIED EXCAVATION". ALL NEW FILL AND UTILITY
TRENCH BACKFILL SHALL BE COMPACTED TO AT LEAST 95% OF MAXIMUM DRY DENSITY
AS DETERMINED BY THE STANDARD PROCTOR (ASTM D-698). IN ADDITION, THE UPPER
18" OF ALL FILL MATERIALS BENEATH FLOOR SLABS AND PAVEMENTS SHALL BE
COMPACTED TO AT LEAST 98% OF THE MAXIMUM DRY DENSITY (ASTM D-698).
10. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST
REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
11. ALL REINFORCED CONCRETE PIPE SHALL BE CLASS III, UNLESS OTHERWISE NOTED, AND
SHALL CONFORM TO SCDOT SPECIFICATIONS. ALL JOINTS SHALL BE TONGUE AND
GROOVE WITH MASTIC MATERIAL.
12. CATCH BASINS SHALL BE PRECAST R.EINFORCED CONCRETE DRAINAGE BOX WITH
SOLID WALL PER SCDOT STANDARD DRAWING 719-17A OR APPROVED EQUAL.
13. ALL WORK ON STATE, COUNTY, OR CITY RIGHT-OF-WAYS, INCLUDING DRIVEWAY
APRONS, WATER AND SEWER TAPS OR ANY OTHER WORK REQUIRES AN
ENCROACHMENT PERMIT FROM THE APPROPRIATE AGENCY.
14. STANDING GRASS MUST BE EVIDENT IN AREAS THAT WERE SEEDED.
15. AN AS-BUILT CERTIFICATION OF THE STORMWATER MANAGEMENT SYSTEM WILL BE
REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE SITE. THE
DESIGN ENGINEER WILL NOT BE RESPONSIBLE FOR THE DELAYS RESULTING FROM
NON-COMPLIANCE WITH THE DESIGN DRAWINGS.
16. CONTRACTOR TO CONFIRM ALL ELEVATIONS AND ADA COMPLIANCE PRIOR TO
INSTALLING CURB, SIDEWALK, OR PAVEMENT AND BRING ANY DISCREPANCIES TO THE
ENGINEER'S ATTENTION.
17. BUILDING ROOF DRAINAGE WILL TIE TO UNDERGROUND STORMWATER DRAINAGE
SYSTEM. COORDINATE WITH MEP PLANS.
DETENTION BASIN MAINTENANCE SCHEDULE
1. THE LANDOWNER, ITS SUCCESSORS AND ASSIGNS, WILL PERFORM THE WORK
NECESSARY TO KEEP THESE FACILITIES IN GOOD WORKING ORDER AS
APPROPRIATE.
2. PERMANENT DETENTION POND TO BE OWNED AND MAINTAINED BY OWNER.
3. GRASS TO BE MOWED ON A REGULAR BASIS (MINIMUM 2 TIMES A YEAR). AREAS NOT
VEGETATED SHOULD BE STABILIZED IMMEDIATELY.
4. DIKE TO BE MAINTAINED WITH PROMPT REPAIR OF ANY ERODED AREAS AND NO TREE
GROWTH ALLOWED TO OCCUR IN THE BERM.
5. TRASH AND DEBRIS TO BE REMOVED FROM WITHIN AND AROUND THE POND ON A
REGULAR BASIS AND AFTER ANY LARGE STORM EVENTS.
6. OUTLET STRUCTURE TO BE INSPECTED FOR STRUCTURE INTEGRITY AND SEDIMENT
TO BE REMOVED IF IT IS RESTRICTING WATER FLOW. REPAIRS TO OUTLET
STRUCTURE TO BE MADE IF NEEDED.
7. SEDIMENT ACCUMULATION TO BE REMOVED FROM POND.
8. POND BOTTOM TO BE INSPECTED AS NECESSARY TO PROVIDE POSITIVE DRAINAGE
TO THE OUTLET. (REFER TO THE CITY OF SPARTANBURG LAND DEVELOPMENT
DIVISION WEBSITE FOR A MORE DETAILED CHECKLIST FOR DETENTION POND
MAINTENANCE.)
I have placed my signature and seal on the design documents
submitted signifying that I accept responsibility for the design
of the system. Further, I certify to the best of my knowledge
and belief that the design is consistent with the requirements
of Title 48, Chapter 14 of the Code of Laws of SC, 1976 as
amended, pursuant to Regulation 72-300 et seq. (if applicable),
and in accordance with the terms and conditions of SCR100000
3:1 SLOPE
3:1
SLOPE
2:1 CUT
SLOPE
8" PVC ROOF
LEADER - REFER
TO MEP FOR
DOWNSPOUT
CONNECTIONS
RIPRAP
APRON
(TYP.)
3' WIDE CONCRETE
FLUME WITH TYPE
16 CURB INLET
3' WIDE CONCRETE
FLUME WITH TYPE
16 CURB INLET
3' WIDE CONCRETE
FLUME WITH TYPE
16 CURB INLET
10' WIDE
EMERGENCY
SPILLWAY
4' TALL FENCE
AROUND POND
(2) 4' WIDE
SWING GATES
(2) 4' WIDE
SWING GATES
4' TALL FENCE
AROUND POND
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
DATE
www.sitedesign-inc.com
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
PH: (864) 285-0618
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.2.3.4.5.6.7.8.9.10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
DANBURY COMMONS
MULTI-FAMILY
S.C. REG 23536
C500
UTILITY PLAN
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
CONNELLY
DEVELOPMENT, LLC
Know what's below.Call before you dig.
EXISTING FIRE SERVICE TO BE
USED - CONTRACTOR TO
COORDINATE RE-ROUTE OF FIRE
SERVICE WITH SPARTANBURG
WATER CROSS CONNECTIONS
EXISTING 2" METER
TO REMAIN AS
DOMESTIC SERVICE
APPROXIMATE
LOCATION OF 6" FIRE
SERVICE CONNECTION
- CONTRACTOR TO
VERIFY
CONTRACTOR TO CONTACT
SPARTANBURG WATER SYSTEMS
PRIOR TO CONNECTION OF
SERVICE TO MANHOLE
PROPOSED 8"
SEWER LATERAL
@ 0.5% MIN. SLOPE
CLEANOUT
MIN. I.E. 830.00'
EXISTING
HYDRANT
REROUTE EXISTING 6" FIRE
SERVICE TO RISER ROOM -
SERVICE TO BE 6" DIP
RISER
ROOM
166.3'
240.6'
233.8'
105.6'
UTILITY NOTES:
1. ALL UTILITIES LOCATED ON THIS PLAN SHOULD BE CONSIDERED APPROXIMATE.
CONTRACTOR SHALL COORDINATE LOCATION OF UNDERGROUND UTILITIES WITH
THE UTILITY LOCATING SERVICE, BY CALLING 811 THREE (3) DAYS PRIOR TO
CONSTRUCTION, AND UTILITY PROVIDERS.
2. CONTRACTOR SHALL NOTIFY THE ENGINEER FOR A REVIEW SHOULD ANY
DISCREPANCIES BE DISCOVERED AT THE SITE OR ON THE DRAWINGS.
3. NEW UTILITY TRENCH BACKFILL SHALL BE COMPACTED TO AT LEAST 95% OF
MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST (ASTM
D-698). IN ADDITION, THE UPPER 18" OF ALL FILL MATERIALS BENEATH FLOOR
SLABS AND PAVEMENTS SHALL BE COMPACTED TO AT LEAST 98% OF THE
MAXIMUM DRY DENSITY (ASTM D-698).
4. CONTRACTOR SHALL CONSTRUCT DOMESTIC WATER SERVICE TO BUILDINGS
SHOWN ON DRAWING. EXACT LINE SIZE, TYPE AND LOCATION TO BE
COORDINATED WITH MEP PLANS AND THE GOVERNING UTILITY AUTHORITY. TAPS
TO BE INSTALLED TO THE SPECIFICATIONS OF THE GOVERNING UTILITY
AUTHORITY.
5. CONTRACTOR SHALL CONSTRUCT SANITARY SEWER SERVICE TO BUILDINGS.
EXACT SIZE, TYPE AND LOCATION TO BE COORDINATED WITH MEP PLANS AND THE
GOVERNING UTILITY AUTHORITY. SERVICE TO BE INSTALLED TO THE
SPECIFICATIONS OF THE GOVERNING UTILITY AUTHORITY. INSTALL CLEAN OUTS
AT 75' INTERVALS (MAX) AND AT ALL DEFLECTIONS.
6. CONTRACTOR SHALL COORDINATE ALL OTHER UTILITY CONNECTIONS WITH LOCAL
PROVIDERS. CONTRACTOR SHALL INSTALL ALL UTILITIES TO THE SPECIFICATIONS
AND REQUIREMENTS OF THE ACCEPTING UTILITY AUTHORITY.
7. THE CONTRACTOR SHALL CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST
REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY UTILITY SCREENING TO MEET
THE REQUIREMENTS OF THE CITY OF SPARTANBURG.
9. OWN/ER/DEVELOPER TO CONTACT SPARTANBURG WATER NEW CONNECTIONS AT
864-583-7361 TO SETUP SMALL METER CONNECTION.
10. OWNER/DEVELOPER TO CONTACT SPARTANBURG WATER NEW CONNECTIONS AT
864-583-7361 TO COORDINATE CONNECTION OF SEWER LATERAL
120.8'125.0'
64.7'
104.7'
USE: VACANT
USE: SINGLE FAMILY
USE: SINGLE FAMILYUSE: VACANT
USE: SINGLE FAMILY
USE: SINGLE FAMILY
USE: MULTI FAMILY
Know what's below.Call before you dig.
PARKING DATA:
1.4 SPACES PER UNIT -
48 UNITS @ 1.4 SPACES PER UNIT = 67 SPACES
REGULAR SPACES PROVIDED: 61 SPACES
HC SPACES PROVIDED:7SPACES
TOTAL PROVIDED: 68 SPACES
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ZONING: DT-4
ROADSIDE BUFFER
1 CANOPY, 2 UNDERSTORY, 4 LARGE EVERGREEN SHRUBS OR 8
SMALL EVERGREEN SHRUBS PER 100 LF
275 LF =12 UNDERSTORY TREES, 22 SMALL EVERGREEN SHRUBS
TYPE 3 BUFFERYARD
6' VINYL FENCE
4 EVERGREEN TREES
TYPE 2 BUFFERYARD (20' WIDE - 0.75
MULTIPLIER)
3 CANOPY, 5 UNDERSTORY, 5
EVERGREEN AND 9 SHRUBS PER 100 LF
121 LF = 4 CANOPY TREES, 4
UNDERSTORY TREES, 6 EVERGREEN
TREES ( EXISTING HEDGE AND (2)
CREPE MYRTLES TO REMAIN)
TYPE 2 BUFFERYARD (10' WIDE)
4 CANOPY, 6 UNDERSTORY, 6 EVERGREEN
AND 12 SHRUBS PER 100 LF
125 LF = 5 CANOPY TREES, 8 UNDERSTORY
TREES, 8 EVERGREEN TREES AND 15
SHRUBS
TYPE 3 BUFFERYARD
6' VINYL FENCE
4 EVERGREEN TREES
ALL REQUIRED PLANTING AREAS SHALL BE MECHANICALLY IRRIGATED. THIS
SHALL INCLUDE ALL TREE ISLANDS AND ALL AREAS OF REQUIRED FRONTAGE
LANDSCAPING BETWEEN THE PARKING LOT AND PUBLIC STREETS. REQUIRED
PLANTING AREAS ASSOCIATED WITH PARKING LOTS CONTAINING LESS THAN
THIRTY (30) PARKING SPACES ARE NOT REQUIRED TO BE IRRIGATED.
HOWEVER, AN EXTERIOR WATER SOURCE (SUCH AS A HOSE BIB) SHALL BE
LOCATED WITHIN 100 FEET OF ALL REQUIRED PLANTING AREAS.
DETENTION
POND
DETENTION
POND
(1) PICH
(1) PICH
(1) PICH
(1) PICH
(1) PICH
(1) PICH
(1) OVAT
(1) OVAT
(1) IAEA
(1) IAEA
(1) OVAT
(1) IAEA
(1) OVAT
(1) CCME
(1) IAEA
(1) LJRE
(1) THEG
(1) OVAT
(1) CCME
(1) THEG
(1) THEG
LOCATION MAP NOT TO SCALE
SHEET OF
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO. DATE
www.sitedesign-inc.com
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
PH: (864) 271-0496
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
1" = 20'
N/A
15
DANBURY COMMONS
MULTI-FAMILY
CONNELLY
DEVELOPMENT, LLC
11/08/2024
S40210/LANDSCAPE
L100
13
LANDSCAPE PLAN
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
AGB
AGB
S.C. REG NO 552
####
####
####
####
####
####
####
####
####
####
####
####
####
####
####
####
####
####
(1) PICH
(1) PICH
BERMUDA SOD (ALL DISTURBED AREAS NOT SHOWN IN SOD OR IN A PLANTING
BED SHALL BE SEEDED PER CIVIL SPECIFICATIONS)
LANDSCAPING NOTE:
·ANY LANDSCAPING PROVIDED SHALL NOT INTERFERE WITH ANY
SIGHT VISIBILITY AT ENTRANCE ONTO FREMONT AVE.
·ANY IRRIGATION INSTALLED FOR SITE SHALL NOT ENCROACH INTO
SCDOT RIGHT OF WAY.
Stateof South Carolina
ALISON G. BRANDTREGISTEREDLANDSCAPEARCHITECT
No. 552
(19) ICSP
EXISTING VEGETATION
EXISTING VEGETATION
EXISTING VEGETATION
(12) LAIK
(24) DIVJ
SCREEN WALL OR FENCE FOR AC UNITS(TYP)
MATERIAL TO COMPLIMENT ARCHITECTURE
SEE DETAIL
SITE DATA
SITE ADDRESS203 FREMONT AVENUE
SPARTANBURG, SC 29303
OWNER/DEVELOPERCONNELLY DEVELOPMENT, INC.
125 OLD CHAPIN ROAD
LEXINGTON, SC 29072
CONTACT: LAURA NICHOLSON
(803) 798-0572
LDN@CONNELLYBUILDERS.COM
CIVIL ENGINEERSITE DESIGN, INC.
1074 ASHEVILLE HWY UNIT B
SPARTANBURG, SC 29303
ARCHITECTPARKS-PLAYER
85 CLEVELAND ST. SUITE 201
GREENVILLE, SC 29601
(864) 382-5000
ZONINGDT-4
DOWNTOWN 4
PROPOSED USEMULTI-FAMILY
TAX MAP #TMS# 7-12-01-080.00
PARCEL AREA1.88 ACRES
SETBACKSFRONT: 6' (MIN.) 18' (MAX)
SIDES: 0'
REAR: 3'
HORZ. SCALE:
VERT. SCALE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DATE:
NO.
www.sitedesign-inc.com
225 ROCKY CREEK ROAD
GREENVILLE, SC 29615
PH: (864) 271-0496
SITE DESIGN, INC.
CIVIL ENGINEERS - SURVEYORS - LANDSCAPE ARCHITECTS1.
2.
3.
4.
5.
6.
7.
8.
9.
10.THIS DRAWING IS THE PROPERTY OF SITE DESIGN, INC. AND IS
FURNISHED WITH THE CONDITION THAT IT IS NOT TO BE CHANGED
WITHOUT THE WRITTEN AUTHORIZATION OF SITE DESIGN, INC.
FURTHERMORE, THIS DRAWING IS NOT TO BE COPIED, REPRODUCED,
OR USED BY OTHERS EXCEPT AS REQUIRED FOR THE WORK OF THIS
SPECIFIC PROJECT.
© 2023 SITE DESIGN, INC.
N/A
15
DANBURY COMMONS
MULTI-FAMILY
CONNELLY
DEVELOPMENT, LLC
AGB
11/08/2024
S40210/LANDSCAPE
AGB
S.C. REG 552
L200
14
LANDSCAPE DETAILS
CITY OF SPARTANBURG
SPARTANBURG COUNTY
SOUTH CAROLINA
N/A
SAUCER SOIL TO
RETAIN WATER
DEEPROOT ARBORTIE
-INSTALLED PER
MANUFACTURER
www.deeproot.com
PULL MULCH AWAY FROM
COLLAR OF TREE
2 X 4" STAKE
ROOTBALL
FINISH
GRADE
BACKFILL
MIXTURE
SUBGRADE
TREE OVER 2" CAL.
3" OR 4" MULCH
EARTH PEDESTAL TO
KEEP TOP OF ROOT BALL
2" ABOVE FINISH GRADE
REMOVE ALL WIRE AND AS
MUCH BURLAP AS POSSIBLE
NOTES:
1. REMOVE WIRE OR NYLON TWINE FROM ROOT BALL
2. INSTALL TOP OF BALL 2" ABOVE FINISH GRADE
3. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION
4. 4" SAUCER WILL BE OUTSIDE OF BACKFILL.
AMENDED SOIL AREA:
ENTIRE PLANTING AREA SHALL BE SCARIFIED AND CONTAIN AMENDED ON-SITE
SOIL OR A SOIL MIX TO A DEPTH OF 18" (IN SOME SITUATIONS, LAWN WILL BE
PLANTED OVER THIS AREA)
MULCH RING FOR TREES IN LAWN MINIMUM 6' DIA.
GUY WIRE 3 - SPACED EQUALLY
AROUND TREE
SAUCER SOIL TO
RETAIN WATER
RUBBER HOSE
AROUND WIRE
SAFETY FLAGGING
PULL MULCH AWAY FROM
COLLAR OF TREE
2 X 4" STAKE
ROOTBALL
FINISH
GRADE
BACKFILL
MIXTURE
SUBGRADE
PREPARE AREA 2 TIMES
WIDTH OF ROOTBALL
MULTI-TRUNK TREE
4" MULCH
EARTH PEDESTAL TO
KEEP TOP OF ROOT BALL
2" ABOVE FINISH GRADE
REMOVE ALL WIRE AND AS
MUCH BURLAP AS POSSIBLE
NOTES:
1. REMOVE WIRE OR NYLON TWINE FROM BALL
2. INSTALL TOP OF BALL 2" ABOVE FINISH GRADE
3. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION
4. LENGTH OF RUBBER HOSE TO BE 2/3 CIRCUMFERENCE OF TREE.
5. 4" SAUCER WILL BE OUTSIDE OF BACKFILL.
SHRUB PLANTING & V-DITCH BED EDGING
3-4"
"V-DITCH" EDGING
ALL BEDLINES
LAWN
6-8"
COMPACTED SOIL MIX
SCARIFY SIDES OF
ROOT BALL
SUBGRADE
4" SOIL SAUCER
NOTES:
1. REMOVE WIRE, NYLON TWINE OR CONTAINER FROM ROOT BALL.
2. SCARIFY SIDES AND BOTTOM OF HOLE AS WELL AS THE ROOT BALL.
3. INSTALL TOP OF BALL 2" ABOVE FINISH GRADE
4. ROOT BALLS GREATER THAN 2' IN DIAMETER SHALL SIT ON MOUND OF UNDISTURBED
SOIL TO PREVENT SETTLING.
5. ROOT BALLS SMALLER THAN 2' MAY SIT ON COMPACTED SOIL MIXTURE.
6. BACKFILL PIT WITH SPECIFIED PLANTING SOIL MIXTURE IN 8" LAYERS, HAND TAMP TO
REMOVE VOIDS.
7. WHEN 23 BACKFILLED, FILL WITH WATER
8. AFTER BACKFILLING AND TAMPING FINAL LAYER, WATER AGAIN UNTIL NO MORE IS
ABSORBED.
9. 4" SAUCER WILL BE OUTSIDE OF BACKFILL.
PREPARE AREA 3 TIMES
WIDTH OF ROOTBALL
3" MULCH (SEE PLANTING
SCHEDULE FOR TYPE)
BACKFILL MIXTURE
GENERAL NOTES & SPECIFICATIONS
LAWN INSTALLATION: LAWN AREAS SHALL BE FINE GRADED TO A SMOOTH, POSITIVELY
DRAINING SLOPE, REMOVING ALL STONES OVER 3/4" . AGRICULTURAL LIMESTONE SHALL BE
INCORPORATED INTO THE SOIL AT A RATE OF 50 POUNDS PER 1000 SQUARE FEET. APPLY
SPECIFIED SEED AT RECOMMENDED RATE. STRAW MULCH OR HYDROMULCH SHALL BE USED
AS DEEMED NECESSARY BY THE LANDSCAPE CONTRACTOR AND LANDSCAPE ARCHITECT.
THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE TO ESTABLISH A FULL STAND OF
GRASS AND WILL REPAIR ANY BARE SPOTS 1'- 0" SQUARE DUE TO UNEVEN SEED
DISTRIBUTION, DROUGHT OR EROSION.
SOD INSTALLATION: SODDED LAWN AREAS SHALL BE FINE GRADED TO A SMOOTH,
POSITIVELY DRAINING SLOPE, REMOVING ALL STONES OVER 3/4" . SOD SHALL BE HEALTHY,
THICK SOD PLACED SO THAT JOINTS ARE BUTT TIGHT. STAPLE AS NECESSARY. SOD SHALL
BE TRIMMED TO MATCH BED LINES SHOWN ON PLAN. STARTUP FERTILIZER SHALL BE
INCORPORATED INTO THE SOIL AT THE MANUFACTURER'S RECOMMENDED RATE. ANY AREA
OF SOD THAT FAILS TO ROOT, SETTLES OR DIES WILL BE REPLACE BY THE LANDSCAPE
CONTRACTOR.
UTILITY LOCATION: THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE
UTILITY LOCATOR SERVICE AND IS RESPONSIBLE FOR ANY DAMAGE DONE TO UTILITIES.
QUANTITIES PLANT QUANTITIES ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY.
PLANTS SHALL BE INSTALLED AS SHOWN. CONTRACTOR IS RESPONSIBLE FOR CONFIRMING
ALL QUANTITIES PRIOR TO BIDDING AND INSTALLATION.
BIDS IN ORDER TO KEEP ALL BIDS STANDARD, ALL BIDS ARE TO HAVE UNIT PRICES LISTED.
THE OWNER HAS THE OPTION TO DELETE ANY PORTION OF THE CONTRACT PRIOR TO SIGNING
THE CONTRACT OR BEGINNING WORK. THIS WILL BE A UNIT PRICE CONTRACT.
PLANT QUALITY ALL PLANTS SHALL BE NURSERY GROWN, HAVE A FULL HABIT OF GROWTH
AS IS CHARACTERISTIC OF THAT SPECIES, AND SHALL BE FREE OF DISEASE OR INSECTS.
GENERAL PLANT QUALITY SHALL BE AS SPECIFIED IN THE "USA STANDARD FOR NURSERY
STOCK" (PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN). PLEASE CONTACT
THE LANDSCAPE ARCHITECT IF THERE IS DIFFICULTY IN LOCATING A PARTICULAR PLANT. IF
NECESSARY, A SUBSTITUTE PLANT WILL BE RECOMMENDED BY THE LANDSCAPE ARCHITECT.
PLANTING AREA PREPARATION: ENTIRE PLANTING AREA SHALL BE SCARIFIED AND CONTAIN
AMENDED ON-SITE SOIL OR A SOIL MIX TO A DEPTH OF NO LESS THAN 18". (SEE PLANTING
DETAIL FOR MORE INFORMATION.)
SETTING OF PLANTS THE ROOT BALL OF CONTAINER GROWN PLANTS SHALL BE SCARIFIED IN
SEVERAL PLACES PRIOR TO PLANTING. PLANT SHRUBS AND TREES SO THAT AFTER INITIAL
SETTLEMENT, THE TOP ROOT BALLS WILL BE EVEN WITH OR SLIGHTLY ABOVE THE ADJACENT
SOIL LINE. AROUND ROOT BALLS, 1/2 OF THE ORIGINAL SOIL SHALL BE REMOVED FROM THE
PLANTING HOLE AND THROUGHLY MIXED WITH THE SAME QUANTITY PEAT MOSS OR WELL
ROTTED, FINE TEXTURED BARK. (ONLY IN AREAS WHERE THE EXISTING SOIL IS 100% FERTILE,
LOOSE TOPSOIL (BROWN OR BLACK IN COLOR) CAN PLANTS BE PLACED DIRECTLY IN THE
SOIL WITH NO AMENDMENTS). PLANTINGS NOT DONE IN THIS MANNER SHALL BE REMOVED
AND PROPERLY REPLANTED.
PREPARATION OF GROUND COVER AND SEASONAL COLOR BEDS : THE EXISTING SOIL IN
GROUND COVER AND SEASONAL COLOR BEDS SHALL BE THOROUGHLY CULTIVATED 6
INCHES DEEP, TO A FINE TEXTURE ( NO CLODS OVER 1/2") WITH A MECHANICAL TILLER. A
PLANT MIX OF 60% SCREENED SHREDDED TOPSOIL, 20% SAND, AND 20% INCORPWELL
ROTTED SAWDUST OR PEAT SHALL THEN BE THOROUGHLY INCORPORATED INTO THE
EXISTING SOIL WITH THE TILLER SO THAT THE SOIL MIX (6" DEEP) IS 1/2 ORIGINAL SOIL AND 1/2
PLANT MIX. ALL GROUNDCOVER AND SEASONAL COLOR BEDS SHALL RECEIVE A 2" LAYER OF
FINE TEXTURED, SCREENED, PINE BARK MULCH, OR EQUAL.
PLANTINGS NOT DONE IN THIS MANNER SHALL BE REMOVED AND PROPERLY REPLANTED.
FERTILIZING UPON COMPLETION OF PLANTINGS, ALL SHRUBS SHALL RECEIVE 1/6 CUP OF
16-4-8 FERTILIZER (50% OF NITROGEN SLOW RELEASE) EVENLY BROADCAST AT THE BASE OF
THE PLANTS. TREES SHALL RECEIVE 1/4 CUP OF 16-4-8 FERTILIZER (50% OF NITROGEN SLOW
RELEASE) PER INCH OF CALIPER. GROUND COVER BEDS SHALL BE FERTILIZED AT THE RATE
OF 20 POUNDS OF 16-4-8 ( 50% OF NITROGEN SLOW RELEASE) PER 1000 SQUARE FEET.
STAKING OF TREES DECIDUOUS TREES, 1 1/2" IN CALIPER AND OVER, AND EVERGREEN
TREES, 8' AND TALLER SHALL BE STAKED. RUBBERHOSE TO BE USED TO COVER THE WIRE AT
THE POINT OF ITS CONTACT WITH THE TREE. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE
FOR ALL WIND DAMAGE TO TREES, (PROVIDED WINDS ARE LESS THAN 60MPH) DURING THE
GUARANTEE PERIOD, AND MAY STAKE OTHER TREES (FOR HIS OWN PROTECTION) AT HIS
OPTION. TRANSPLANTS ALL PLANT MATERIAL TO BE TRANSPLANTED SHALL BE
TRANSPLANTED ACCORDING TO GUIDELINES SET BY AAN STANDARDS. TRANSPLANTED
MATERIAL WILL NOT BE GUARANTEED BY THE LANDSCAPE CONTRACTOR.
MULCHING AS SPECIFIED ON PLANTING LIST. HARDWOOD MULCH: ALL BEDS TO RECEIVE A 3"
LAYER OF AGED HARDWOOD BARK MULCH (FREE OF WOOD CHIPS OR LARGE CHUNKS OF
BARK). FRESH HARDWOOD BARK MULCH IS NOT RECOMMENDED TO BE USED, AS WATER
RUN-OFF MAY CAUSE STAINING ON ADJACENT CONCRETE SURFACES. ALL DAMAGES
INCURRED BY THE USE OF FRESH HARDWOOD MULCH SHALL BE THE RESPONSIBILITY OF THE
LANDSCAPE CONTRACTOR. PINESTRAW: ALL BEDS TO RECEIVE A 4" LAYER (PRIOR TO
COMPACTION) OF PINESTRAW. AFTER NATURAL COMPACTION, PINESTRAW SHOULD HAVE A
DEPTH OF 2". ALL TREES LOCATED IN LAWN AREAS SHALL RECEIVE A 3' DIAMETER RING OF
MULCH. MULCH IN THESE AREAS IS TO FOLLOW THE ABOVE LISTED GUIDELINES. A WEED
BARRIER SHALL BE PROVIDED IN ALL BED AREAS UNDER MULCH LAYER.
GRADING ALL FINAL GRADING SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE
CONTRACTOR. THE RESPONSIBILITY FOR ANY ADDITIONAL GRADING (IF NEEDED) SHALL BE
DETERMINED PRIOR TO BIDDING.
BACKFILL LANDSCAPE CONTRACTOR TO VERIFY ANY ADDITIONAL BACKFILL/TOPSOIL
NEEDED PRIOR TO BEGINNING WORK. A UNIT PRICE FOR TOPSOIL SHALL BE INCLUDED IN ALL
BID DOCUMENTS TO ALLOW FOR CIRCUMSTANCES THAT MIGHT ARISE DURING INSTALLATION.
STABILIZATION LANDSCAPE CONTRACTOR SHALL ENSURE THAT ALL PLANTINGS ARE
STABILIZED WITH GROUND COVERS, MULCHES OR OTHER APPROVED MATERIALS TO
PREVENT SOIL EROSION AND ALLOW RAINWATER INFILTRATION.
CLEAN UP FINAL CLEAN UP OF ANY DISTURBANCES OCCURRING AS A RESULT OF
LANDSCAPE OPERATIONS SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR.
INSPECTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE FOR INSPECTION
OF THE PLANT MATERIAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. ALL
PLANT MATERIAL WILL BE INSPECTED. PLANTS NOT CONFORMING PRECISELY TO THE PLANT
LIST WILL NOT BE ACCEPTED AND SHALL BE REPLACED AT THE CONTRACTOR'S OWN
EXPENSE.
LICENSES THE CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ALL LICENSES
NECESSARY TO COMPLETE THE WORK.
INSURANCE WITH THE SUBMITTAL OF BID DOCUMENTS, THE LANDSCAPE CONTRACTOR
SHALL ALSO SUBMIT A CERTIFICATE OF INSURANCE FOR WORKMAN'S COMPENSATION AND A
CONTRACTOR'S GENERAL LIABILITY. CONTRACTORS NOT PROVIDING EVIDENCE OF SUCH
INSURANCE WILL BE INELIGIBLE TO RECIEVE THE CONTRACT FOR THE JOB
GUARANTEE ALL PLANT MATERIAL AND WORKMANSHIP TO BE GUARANTEED FOR ONE YEAR
FROM THE DATE OF ACCEPTANCE BY THE OWNER. PLANT REPLACEMENT TO OCCUR ONLY
ONCE. THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR DEFECTS RESULTING FROM
NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS, OR UNUSUAL PHENOMENA OR
INCIDENTS BEYOND THE LANDSCAPE CONTRACTORS CONTROL WHICH RESULT FROM
NATURAL CAUSES SUCH AS FLOODS, LIGHTNING, STORMS, FREEZING RAINS, OR WINDS OVER
60 MILES PER HOUR, FIRE, VANDALISM OR THEFT.
IRRIGATION UNLESS OTHERWISE SPECIFIED, IF AN AUTOMATIC IRRIGATION SYSTEM IS
DESIRED OR REQUIRED, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE THE
SYSTEM DESIGNED AND INSTALLED.
Stateof South Carolina
ALISON G. BRANDTREGISTEREDLANDSCAPEARCHITECT
No. 552
24" MIN
AC UNIT
1"
48"
8' MAX
1" X 6" COMPOSITE WOOD
4" X 4" COMPOSITE POST
2'-6" 2"
6"
12"
1" X 6" COMMPOSITE CAP
1" X 4" COMPOSITE WOOD
4" X 4" COMPOSITE WOOD POST
PROVIDE REMOVABLE
PANEL FOR MAINTENANCE
ACCESS
1" X 6" COMPOSITE CAP
(OPTIONAL)EVERGREEN SHRUBS (48"
HT WHEN PLANTED, 48" OC) TO
SCREEN AC UNIT ON ALL SIDES
VISIBLE TO THE PUBLIC
AC UNIT /TRANSFORMER SCREENING
(MATERIAL TO COMPLIMENT ARCHITECTURE)
Source: City of Spartanburg website. First collected Oct 24, 2026.