RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Nov 25, 2025 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Tuesday, November 25, 2025, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Benjamin M. Racusin Council Chambers The Design Review Board meeting will be held in person at Town Hall in the Benjamin M. Racusin Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of November 12, 2025 4. Unfinished Business a. DRB-001095-2025 - 70 Beach City Road — First African Baptist Church - Final 5. New Business a. DRB-001104-2025 - 2 Lafayette Place — Chase Bank - Alteration 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as Page 1 of 86 soon as possible but no later than 48 hours before the scheduled event. Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 86 Town of Hilton Head Island Design Review Board Meeting Minutes 11/12/2025 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Wednesday, November 12, 2025, 2:30 PM Minutes 1. Call to Order Chair Carstens called the meeting to order at 2:33 pm. In attendance: Chairman Judd Carstens, Megan Fitzpatrick, Todd Theodore, Cathy Foss. Vice Chair Annette Lippert, Patty Pastor and Tom Parker (recused) were excused. 2. Adoption of the Agenda Mr. Theodore made a motion to adopt the agenda. Ms. Fitzpatrick seconded. The motion passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of October 28, 2025 Ms. Foss made a motion to approve the meeting minutes of October 28, 2025. Mr. Theodore seconded. The motion passed unanimously. 4. Unfinished Business a. DRB-001075-2025 - Sandalwood Food Pantry - 8 August Lane - Final Melissa Paul-Leto presented the Sandalwood Food Pantry for final review. The applicant answered questions from the Board. Ms. Fitzpatrick motioned to approve with the following conditions: include exterior lighting cut sheet; add gravel to connect pathway; ensure gates and hardware on barn doors will be dark bronze. Ms. Foss seconded. The motion passed unanimously. 5. New Business 6. Public Comment - Non Agenda Items 7. Board Business The Board called for confirmation at the earliest opportunity that the next meeting will be held on the 25th. A follow-up discussion on signage and window pane color for One Hot Mama's was requested. 8. Staff Reports 9. Adjournment The meeting adjourned at 2:50pm. Page 3 of 86 Town of Hilton Head Island Design Review Board Meeting Minutes 11/12/2025 Page | 2 Page 4 of 86 Page 5 of 86 Megan Smith, PE 171 Church St, Charleston, SC 29401 LJA Engineering, INC. Charleston SC 29401 843-886-1871 mesmith@lja.com First African Baptist Church 70 Beach City Rd, Hilton Head Island, SC 29926 510-008-000-001B-0000 Light Commercial (LC) Corridor (COR) N/A X Page 6 of 86 X 10-27-2025 X X X X X X Page 7 of 86 Page 8 of 86 October 31, 2025 Town of Hilton Head Community Development Department One Town Center Court Hilton Head Island, South Carolina 29926 RE: Project Narrative First African Baptist Church – Major Site Development Application 70 Beach City Rd. Hilton Head Island, South Carolina 29926 To whom this may concern: LJA Engineering, Inc. is submitting the following Project Narrative on behalf of FIRST AFRICAN BAPTIST CHURCH TRUSTEES (“Owner / Developer ”), for a proposed religious institution on approximately 1.56 -acres within the jurisdiction of the Town of Hilton Head, Beaufort County, South Carolina (“Town”). The lot is zoned in the Light Commercial Zoning District (LC) per the Town Zoning Map which allows the proposed residential land use . The associated Tax Map number is listed as TMS No. R510-008-000-001B-0000 per GIS Maps. The lot is located along Beach City Road (SCDOT). The lot is currently developed with an existing religious institution, the Historic First African Baptist Church (1-story) with approximately 7 gravel parking spaces, a grassed parking area, two (2)-driveways, and several protected trees. A pre-application meeting was held on August 7, 2025. 3 (PAPP-000750-2025). The project is proposing a 4,560 sq. ft. building that will serve as the main sanctuary for First African Baptist Church. The existing building will then be used as a fellowship area for the congregation. The project is disturbing less than 0.813-acres and is greater than 0.5 -miles from a receiving coastal water body. The sections below summary the various aspects of the project. Building Improvement Summary • The project proposes a 4,560 SF fellowship building. • The new building includes a sanctuary, several offices, and restrooms. • The building is proposed with a height of 26’ -10 5/8”, and maximum steeple height of approximately 21’. Site Improvement Summary • Provide drives and associated parking throughout the site. • Pervious parking area will serve as an infiltration basin to treat both water quantity and quality. • Install accessible walkways leading from the exterior doors to the parking lot around the proposed building. • Provide a new fire hydrant and new fire lanes to meet current IFC requirements. • The project offers 67 parking spaces, 3 of which are ADA parking spaces. Page 9 of 86 70 Beach City Rd. – Hilton Head Island, SC Major Site Development Application Project Narrative October 31, 2025 Page 2 of 3 • The project proposes 4 bicycle parking spaces. • Removal of 18 of the 74 surveyed trees currently on the site. • The existing drivewa y which ties into Beach City Road will provide access to both the proposed and existing buildings. Utilities Fire service will be provided by Hilton Head Public Service District (HHPSD) via the construction of a 6” water line that will connect to an existing 8” main that runs parallel to Beach City Rd. In addition to supplying the building with water for its sprinkler system, the fire line will also serve the new fire hydrant. Private water service will be provided through the construction of a new 1” water line, which will stem off the proposed 6” fire line. The fire line, hydrant, FDC, and private/irrigation meters will be placed in a 10’ HHPSD easement. Sewer service will also be provided by HHPSD via the construction of a 6” sewer line and E-One grinder pump that will service both the existing and proposed buildings. The sewer line will carry effluent to the proposed grinder pump, which will connect to the existing 2” force main. Impervious Cover The project will have a net removal (or reduction) of 1,218 -SF of impervious cover (for a total of 19,307-SF of IC. Drainage Compliance to mitigate the risk of flooding and other applicable Town drainage criteria is provided through the reduction of peak flow rates from the subject property . This is achieved by reducing impervious cover on the site and avoiding changes to existing drainage patterns in the developed condition drainage study. The enclosed Engineering Report details the drainage study and how reduction in peak flow rates was achieved without any permanent BMPs on -site. Overall, this project will enhance the drainage conditions of the site and surrounding area and does not have any adverse impacts between current existing conditions and proposed final conditions. Environmental Issues / Floodplain No environmental features have been identified on site. The tract is located outside of a FEMA 100- year floodplain according to FEMA FIRM 45013C0452G for the Town of Hilton Head Island, effective on March 23, 2021 Buffers The adjacent street buffer for Beach City Road (Minor Arterial) is a 15’-25’ Type B. No adjacent use buffer is required per the Town of Hilton Head Land Management Ordinance . The buffers and setbacks are delineated and labeled all plan sheets. Page 10 of 86 70 Beach City Rd. – Hilton Head Island, SC Major Site Development Application Project Narrative October 31, 2025 Page 3 of 3 We trust this information will help in your evaluation of the project. If you have any questions, do not hesitate to call or email at (843)-886-1871 or email at mesmith@lja.com Sincerely, Megan E. Smith, P.E. Sr. Project Manager LJA Engineering, Inc. Page 11 of 86 Page 12 of 86 V A C C A R O ARCHITECTURE, INC. 31Oglethorpe Lane, Hilton Head Island, SC 29926 Phone: (843) 290-3076 • Email: mikevaccaro7@yahoo.com Friday, November 14, 2025 Mellisa Paul- Leto RE: HISTORIC First African Baptist Church Dear Melissa: Per your letter, the Conceptual submittal for DRB-000809-2025 at 70 Beach City Road for the First African Baptist Church Sanctuary has been approved with the following conditions: Please see our responses below. 1. Study the proportion of the windows in comparison with the shutters. a. Shutters were removed. All of the windows will be stained glass. Pilasters were added to in between the windows to match the existing building. 2. Show the downspouts. a. Downspouts have been shown. 3. Study the addition of corner pilasters to be similar to the pilaster of the existing church. a. Corner pilasters have been added. 4. Show the existing church in elevation with the proposed sanctuary for comparison with the correct floor elevations on both. a. The existing church elevation is shown. 5. The awning over the side entry door seems too large, so please take a look at that. a. The awning was minimized 6. Show the entry door detail (head, jamb, sill). a. Entry door detail is shown 7. Include foundation plantings in the front and around the building, along with palm trees added to the entry. a. See the landscape plans 8. Provide the spec on new steeple. a. A steeple cut sheet is included 9. Indicate the proper grading on the complete elevations. a. Proper grading is shown 10. Indicate if the steeple is being kept on the existing structure. a. Existing steeple will be removed 11. Study the number of outriggers in the front. a. An extensive study was done on the outriggers 12. Provide a materials board. a. Per discussion with Mellisa Paul-Leto no board will be provided. All aspects of the new building will match the existing in texture and color as shown in photos. 13. Indicate that the utilities will be screened and provide the spec of that screening. a. Utilites will be screened 14. Provide lighting specs for the exterior lighting on the building. a. Lighting spec sheets will be provided 15. Provide an existing and proposed landscape plan. a. An existing and new landscape plan is provided. Please feel free to contact me to discuss. Sincerely, Michael A. Vaccaro, AIA, NCARB President | VACCARO ARCHITECTURE, INC. SC Registered Architect #6618 Page 13 of 86 Page 14 of 86 CODE COMPLIANCE SUMMARY (NEW BUILDING) PROJECT IS A NEW CHURCH BUILDING ON THE SAME PROPERTY AS THE EXISTING CHURCH BUILDING PRIMARY USE IS ASSEMBLY MAIN USE GROUP A-3 ASSEMBLY CONSTRUCTION TYPE VB UNPROTECTED - NOTE BUILDING IS FULLY SPRINKLERED ALLOWABLE BUILDING HEIGHT / STORIES N/A (EXISTING BUILDING) HEIGHT MODIFICATIONS N/A ALLOWABLE BUILDING AREA N/A (EXISTING BUILDING) (INCLUDING ALLOWABLE AREA INCREASES FOR FULLY SPRINKLERED BUILDING & OPEN SPACES) PER FLOOR ALLOWABLE AREA N/A ACTUAL BUILDING AREA, GROSS, N/A (EXISTING BUILDING) INCLUDES USABLE EXTERIOR AREAS UNDER ROOF TOTAL GROSS AREA OF BUILDING 4466 SQUARE FEET OCCUPANT LOADS BUSINESS GROUP (1/150 GROSS SF) # OF OCCUPANTS = 3 (331/150) A3 CHURCH with FIXED SEATING = 200 (ACTUAL SEAT COUNT) A2 UNCONCENTRATED (1/15 NET SF) # OF OCCUPANTS = 12 (169/15)' 215 OCCUPANTS = TOTAL OCCUPANT LOAD EGRESS EGRESS WIDTH 44" REQUIRED / (44"+ PROVIDED) NUMBER OF EXITS 2 REQUIRED / (3 PROVIDED) SPRINKLERED YES MAXIMUM TRAVEL DISTANCE LESS THAN 100 FEET FIRE RESISTANCE STRUCTURAL FRAME ... BEARING WALLS - EXTERIOR ... BEARING WALLS - INTERIOR CLASS "B" NON BEARING EXTERIOR PARTITION WALLS NONE NON BEARING INTERIOR PARTITION WALLS CLASS "C" FLOORS ... ROOF CONSTRUCTION ... ROOF CLASSIFICATION ... INTERIOR ROOM FINISH CLASSIFICATION CLASS "C" PLUMBING FIXTURES PLACES OF WORSHIP WATER CLOSETS 1/150 MALE = (283/2)/150=1 WATER CLOSET MALE WATER CLOSETS 1/150 FEMALE = (283/2)/75 =2 WATER CLOSETS FEMALE LAVATORIES 1/200 = (283/200) = 2 LAVATORIES DRINKING FOUNTAIN 1/1000 = 1 DRINKING FOUNTAIN OTHER = 1 SERVICE SINK REQUIRED CODE COMPLIANCE SUMMARY (EXISTING BUILDING) EXISTING CHURCH BUILDING TO REMAIN UNALTERED PRIMARY USE IS ASSEMBLY MAIN USE GROUP A-3 ASSEMBLY CONSTRUCTION TYPE VB UNPROTECTED - TOTAL AREA 4365 SQUARE FEET OCCUPANT LOADS BUSINESS GROUP (1/150 GROSS SF) # OF OCCUPANTS = 1 (64/150) A3 UNCONCENTRATED (1/15 NET SF) # OF OCCUPANTS = 132 (1974/15) 133 OCCUPANTS = TOTAL OCCUPANT LOAD FIRE RESISTANCE EXISTING UNCHANGED PLUMBING FIXTURES ACTUAL COUNT UNCHANGEDTOTAL OCCUPANT LOAD OF BOTH BUILDINGS COMBINED IS 348 OCCUPANTS OCCUPANCY FOR PARKING CALCULATIONS: THIS IS A RELIGIOUS INSTITUTION WITH 200 SEATS 2687 SF SANCTUARY 010 144 SF MULTI-PURPOSE ROOM 011 378 SF HALL 014 169 SF VESTIBULE 018 84 SF ADMINISTRATIVE 021 187 SF MEN'S RESTROOM 025 196 SF WOMEN'S RESTROOM 026 129 SF PASTOR OFFICE 030 200 SEAT CAPACITY This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:16 AM A-001 COVER The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA historic FIRST AFRICAN BAPTIST CHURCH 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA Sheet List Sheet Number Sheet Name A-001 COVER A -010 SITE PLAN A-101 FOUNDATION PLAN A-110 FIRST FLOOR A-111 FIRST FLOOR RCP A-190 ROOF PLAN A-200 ELEVATIONS A-201 ELEVATIONS - FRONT A-202 ELEVATIONS - REAR A-203 ELEVATIONS - LEFT A-204 ELEVATIONS - RIGHT A-300 BUILDING SECTIONS A-301 BUILDING SECTIONS A-330 WALL SECTIONS A-331 STEEPLE A-401 DOOR & WINDOW SCHEDULES A-402 DOOR & WINDOW DETAILS A-601 ADA and ANSI Standard Details A-602 ADA & ANSI DETAILS A-603 ADA & ANSI DETAILS A-700 3D VIEWS Grand total: 21 The Page 15 of 86 BUFFER AND SETBACK STANDARDS: From Beach City Road Buffer = Type B Setback = 40 ft /70° From R511 008 000 0172 0000 Buffer = n/a Setback = 20 ft/75° From R510 008 000 0238 0000 Buffer = Type A Setback = 20 ft/75° From R510 008 000 0001 0000 Buffer = Type A Setback = 20 ft/75° NEW CHURCH BUILDING RELOCATE ALL HVAC TO THIS SIDE OF NEW BUILDING REMOVE/RELOCATE SHEDS 81.600 81 19/32" 123.600 123 19/32" 144.000 144" 132.000 132" 129.600 129 19/32" 134.400 134 13/32" 153.600 153 19/32" www.VaccaroArchitecture.com 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE V A C C A R O ARCHITECTURE, INC. 10/29/2025 11:19:19 AM A-010 SITE PLAN The Historic First African Baptist Church 1" = 20'-0"1 ARCHITECTURAL SITE PLAN Page 16 of 86 B B 2 2 3 3 1 1 4 4 C C A A 62' - 0" 72' - 0" 6' - 0" 78' - 0" 1' - 0" 23' - 4" 23' - 4" 23' - 4" 1' - 0" 0' - 6" 30' - 6" 30' - 6" 0' - 6" 23' - 0" 16' - 0" 23' - 0" 62' - 0" 7' - 4 1/2" 10' - 3 1/8" 5' - 11 3/32" 150.00° 30.00° 19' - 3" 17' - 9" 17' - 9" 19' - 3" 16' - 7" 9' - 0" 44' - 8 1/2" 8' - 3 1/2" 4' - 3 1/2" 40' - 5" 4' - 1 1/2" 12' - 5 1/2" 8' - 3 1/2" 0' - 8 1/2" 44' - 8 1/2" 8' - 3 1/2" 31' - 0" 31' - 0" WOOD FRAMED RAISED PLATFORM 1 A-300 1 A-300 2 A-300 2 A-300 1 A-330 23' - 11 3/4" 1 A-301 1 A-301 2 A-301 2 A-301 3 A-301 3 A-301 This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:20 AM A-101 FOUNDATION PLAN The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA Page 17 of 86 A-201 1 A-203 1 A-2041 B B 2 2 78' - 0" 9' - 5" 2687 SF SANCTUARY 010 3 3 1 1 4 4 C C A A 62' - 0" 16' - 0" 6' - 0" 169 SF VESTIBULE 018 72' - 0" 85 SF SOUND PLATFORM 024 187 SF MEN'S RESTROOM 025 196 SF WOMEN'S RESTROOM 026 78' - 0" 4' - 8" 5' - 8" 5' - 8" 1' - 0" 23' - 4" 23' - 4" 23' - 4" 1' - 0" 9' - 4" 3' - 8" 9' - 4" 12' - 3 1/2" 6' - 0" 1' - 0" 5' - 3 1/2"51' - 8"3' - 11 1/2" 9' - 1" 1' - 0" 6 SF CLOSET 027 6 SF CLOSET 028 3' - 8" 3' - 10" 84 SF ADMINISTRATIVE 021 144 SF MULTI-PURPOSE ROOM 011 378 SF HALL 014 45 SF BATHROOM 029 129 SF PASTOR OFFICE 030 E101 (2) 48"X 108" E106 (1) 36"X 96" E116 (1) 36"X 96" 104 W108 102 103 W112 W113 105 111 117 D119 110 D120 W111 D121 109 W109 W107 W101 W102 E101B (1) 24"X 108" E101A (1) 24"X 108" 112 10' - 0"6' - 7" 11' - 0" 11' - 6" 8' - 0" 8' - 0" 11' - 6" 11' - 0" 1' - 0" 9' - 1" 8' - 5" 3' - 11" 1' - 11" 23' - 4" 14' - 3 1/2" 9' - 0 1/2" 1' - 0" 9' - 1" 8' - 5" 3' - 11" 1' - 11" 5' - 10" 11' - 8" 5' - 10" 5' - 10" 8' - 5 1/2" 9' - 0 1/2" 1 A-300 1 A-300 2 A-300 2 A-300 1 A-330 9' - 4" 6' - 0" 7' - 4 1/2" 2' - 6" 8 SF MOP 034 14' - 0" 6' - 8" 10' - 3 1/2" 6' - 6 1/2" 200 SEAT CAPACITY 30.00° 30.00° 150.00° 0' - 6" 7' - 7 1/2" 8' - 2" 2' - 5" 5' - 3 1/2" 7' - 0" 7' - 3 1/2" 7' - 5" 8' - 6" 7' - 3 1/2" 0' - 6" 61' - 0" 23' - 4" 23' - 4" 23' - 4" 30' - 6" 30' - 6" D124 123 D-ENTRY DOOR/A -401 DSIDE DOORS/A -401 DRISER ROOMDOOR/A -401 WSHUTTERS/ - WTYPICALWINDOW/A -401 1 A-301 1 A-301 2 A-301 2 A-301 3 A-301 3 A-301 17' - 6"11' - 8"11' - 8"11' - 8"17' - 6" A-200 1 - - -- 43 SF RISER 036 67 SF ADA RESTROOM 035 21 SF ELECTRICAL 037 124 125 E128 (1) 36"X 96" 126 This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:21 AM A-110 FIRST FLOOR The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 First Floor Conditioned Floor Schedule Area Level Comments 4 560 SF First Floor Heated 4560 SF Page 18 of 86 A-203 1 A-2041 B B 2 2 3 3 1 1 4 4 C C A A 1 A-300 1 A-300 2 A-300 2 A-300 1 A-330 D-ENTRY DOOR/A -401 DSIDE DOORS/A -401 DRISER ROOMDOOR/A -401 WSHUTTERS/ - WTYPICALWINDOW/A -401 1 A-301 1 A-301 2 A-301 2 A-301 3 A-301 3" / 12" 3" / 12" SLOPED GYPSUM BOARD CEILING MECHANICAL MEZZANINE MECHANICAL MEZZANINE MECHANICAL MEZZANINE HEADER ACROSS HEADER ACROSS 37' - 4 5/8" 29' - 9" 31' - 9" PULL DOWN STAIR PULL DOWN STAIR PULL DOWN STAIR - - -- This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:22 AM A-111 FIRST FLOOR RCP The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 First Floor RCP Page 19 of 86 A-201 1 A-203 1 B B 2 2 3 3 1 1 4 4 C C A A 4 3/4" / 12" 4 3/4" / 12" 4 3/4" / 12" 4 3/4" / 12" 1 A-300 1 A-300 2 A-300 2 A-300 1 A-330 DSIDE DOORS/A -401 1 A-301 1 A-301 2 A-301 2 A-301 3 A-301 A-200 1 - - THERMAL & MOISTURE PROTECTION WATERPROOFING A. Flat roofs (or decks with waterproof membranes): 1. Fully adhered double layer EPDM membrane if exposed to weather 2. TPO where pre-approved by architect in writing B. Sill pan: Pre-formed, pre-welded solid copper sill pan MOISTURE RETARDANTS A. See Foundation for underslab treatments B. See Wall sections for Plywood Sheathing requirements at walls C. Roof Underlayment: Ice & Water shield to be installed at entire roof surface. INSULATION A. Thicknesses shall achieve the following insulation value minimums: 1. Walls: R-19 2. Ceilings: R-38 -unless insulated attic is above 3. Floors: R-25 4. Floors over exterior: R-25 5. Rafters over conditioned spaces: R-38 B. Exterior Walls: Icenene Open Cell Spray Foam C. Roof: Icenene Open Cell Spray Foam D. Underfloor in enclosed Garages: Icenene Open Cell Spray Foam E. Underfloor at Exteriors: Icenene Closed Cell Spray Foam F. Rim Joist: Icenene Open Cell Spray Foam G. Windows/Doors: Low expansion closed-cell spray foam insulation H. Sound: See interior details ENVELOPE VENTILATION A. Ridge vent: N/A B. Provide make up air as required for appliances C. Provide make up airs as required for HVAC system ROOF FINISHES A. Metal Roofs: 1. 4M METALS 1. 1" Snap Lock Panel; 2. Color : TO MATCH ADJACENT CHURCH BUILDING (OLD SANCTUARY) ROOF ACCESSORIES A. Gutters: none B. Roof Fascia: metal kickout flashing C. Vent Stacks: pvc vent stacks paint to match roof or metal to match roofing. SEALANTS A. Sealant Type 1: Non-sag Polyurethane - Pecora Dynatrol II or Tremco Dymeric Plus. Provide non-sag polyurethane sealant for all exterior joints not indicated to be sealed with another sealant. B. Sealant Type 2: Acrylic Latex – Pecora AC-20, Tremco Acrylic Latex, or Sonneborne Sonolac. Provide acrylic latex sealant for typical interior joints. C. Sealant Type 3: Mildew Resistant Silicone Rubber – Provide Pecora 863, Tremco Proglaze, or General Electric 1700. Provide silicone rubber sealant for all interior joints in wet areas. D. Sealant Type 4: Window and Door Sealant – Provide DAPtex® Plus Window & Door Foam Sealant or Architect approved equal. Provide low expansion spray foam at all doors and windows to seal all rough opening gaps. E. Installation: Clean joint surfaces immediately before installation. Remove all substances which could interfere with bond. Etch or roughen joint surfaces to improve bond. Provide backer rods for all liquid sealants to the greatest extents possible. Prevent three- sided adhesion by use of bond breaker tapes or backer rods. Force sealant into joints to provide uniform, dense, continuous ribbons free from gaps and air pockets. Dry tool sealants into joints to form a smooth dense surface. Make joint depth equal joint width for joints up to ½” wide. For joints over ½” wide, make depth equal to one-half of the joint width. Cure sealants in strict compliance with manufacturers’ instructions and recommendations to obtain highest quality surface and maximum adhesion. FLASHING A. Material: Metal flashings to be lead coated copper, 20 oz. unless otherwise specified. B. Fasteners: Same material as flashing or approved for use with flashing material. Conceal all fasteners. C. Sealant: One-part, copper compatible elastomeric polyurethane, polysulfide, butyl or silicone rubber sealant as tested by sealant manufacturer for copper substrates as required.] D. Joints: All joints in continuous metal flashing should be ½” wide lock-seam joints. Simple lap joints are not acceptable. Where required to be waterproof, fill seams with sealant. E. Metal Accessories: Provide sheet metal clips, straps, anchoring devices, and similar accessory units as required for installation of work, matching or compatible with material being installed, non- corrosive, size and gauge required for performance. F. Sill Pans: At all exterior doors and windows, with the exception of the Screen Porch doors and panels, provide prefabricated sill pans with pre-molded corners. Sill pans to have raised ribs to allow water drainage. Marvin SillGuard, Weather Out Flashings, or Architect approved equal. Lap and seal sill pans per manufacturer’s recommendations. G. Roof outlets: Provide metal flashing sleeves for all roof penetrations (vent stacks, etc.) This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:23 AM A-190 ROOF PLAN The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA Page 20 of 86 REMOVE EXISTING STEEPLE This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:31 AM A-200 ELEVATIONS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/8" = 1'-0"1 FRONT Copy 1 Page 21 of 86 0'-0" AMSL 0' - 0" 0'-0" AMSL 0' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" 14' - 0" B CA VESTIBULE PLATE 33' - 9" 16' - 0" A-203 2 Sim E101 W101 W102 E101BE101A 4 3/4" / 12" 26' - 10 5/8" DECORATIVE WOOD OUTRIGGER STUCCO TO MATCH EXISTING ADJACENT BUILDING 2 A-300 2 A-300 A-330 2 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 22' - 5 27/32" Existing First Floor 20' - 0" Existing First Floor 20' - 0" STUCCO OVER 3" FOAM 17' - 3 1/16" EXISTING BUILDING NEW BUILDING 2' - 6" 1' - 6" 18X30 CUT STONE CORNERSTONE :TEXT AS APPROVED BY CHURCH 7' - 7 1/16" 12' - 4" A-402 4 Sim EXTERIOR WOODWORK A. Exterior Wood Standing and Running Trim 1. Thresholds – provide shop drawings to architect for review prior to install at all exterior doors. 2. Ceilings – double “V” grooved cedar or cyprus tongue and groove 1x6 3. Wood mounting blocks. Mount all hose bibs, exterior electrical outlets, and exterior wall lights at wood siding on wood mounting blocks. Wood blocks to be 2” nominal thickness and in Pressure Treated Super Select KDAT SYP wood finished to match trim. Blocks to center on coursing as appropriate – see Drawings. Provide metal head flashing over all blocks. B. Exterior Simulated Wood Standing and Running Trim 1. Door and Window Trim STUCCO OVER FOAM - SEE DETAILS with Smooth finish 2. Soffits – Pressure Treated Super Select KDAT as per drawings C. Fasteners: use stainless steel nail fasteners or Architect approved equal manufacturer approved fastening. Conceal nails to the greatest extent possible. D. Apply touch-up stain to all cuts, planed areas, and other areas where the wood is exposed, whether it is apparent or not. Touch up, as much as possible, the non-apparent areas before installing the board. E. Provide work to sizes, shapes, and profiles indicated. Install work to comply with quality standards referenced. Back prime all work and install plumb, level and straight with tight joints; scribe work to fit. EXTERIOR SIDING + WALL FINISHES A. Stucco: MasterWall Ready Cemplaster Fiber Stucco (or equal) 1. MATCH EXISTING ADJACENT BUILDING 2. Install per manufacturer 3. Install foam stucco accent pieces per mfr. B. Trim: STUCCO ON FOAM TO MATCH BODY COLOR STUCCO A. Exterior Stucco A. MASTERWALL CEMPLASTER STUCCO level II SYSTEM 1. Reference: Masterwall suggested details and architectural drawings for specific detail requirements 2. Slope all surfaces min 1:2 to shed water 3. Two layers 30# felt weather barrier 4. Expansion joints per mfr, and as directed and at common areas of movement. 5. Metal lath meeting ASTMc-847, c926, and C1063 fasten per Masterwall typical details 6. Master wall CEMPLASTER FIELD MIXED STUCCO 7. SAND PER ASTM C897 8. Finish Texture – #1 smooth B. Apply system in strict accordance with Manufacturer recommendations This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:38 AM A-201 ELEVATIONS - FRONT The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 FRONT Page 22 of 86 0'-0" AMSL 0' - 0" 0'-0" AMSL 0' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" BC A 2 A-300 2 A-300 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" Existing First Floor 20' - 0" Existing First Floor 20' - 0" This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:45 AM A-202 ELEVATIONS - REAR The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 REAR Page 23 of 86 0'-0" AMSL 0' - 0" 0'-0" AMSL 0' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" 2 31 4 VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 1 A-300 1 A-300 1 A-330 A-203 2 Sim 16" 72" 16" 9' - 7 1/2" 1 A-301 1 A-301 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 2 A-301 2 A-301 3 A-301 Existing First Floor 20' - 0" Existing First Floor 20' - 0" 0' - 5" FRONT SIDE BULBED RIDGE CAP EAGLE'S BEAK TERMINATION 0' - 2 1/2" This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:19:53 AM A-203 ELEVATIONS - LEFT The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 LEFT 1 1/2" = 1' -0"2 RIDGE CAP PROFILE Page 24 of 86 0'-0" AMSL 0' - 0" 0'-0" AMSL 0' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" ROF 73' - 0" ROF 73' - 0" 23 14 platform 19' - 3" platform 19' - 3" VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 1 A-300 1 A-300 1 A-330 A-330 2 Sim 1 A-301 1 A-301 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 2 A-301 2 A-301 3 A-301 Existing First Floor 20' - 0" Existing First Floor 20' - 0" STUCCO OVER FOAM PILASTER A-402 4 Sim This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:02 AM A-204 ELEVATIONS - RIGHT The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 RIGHT Page 25 of 86 First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" Collar Tie (clg.) 51' - 4 3/4" Collar Tie (clg.) 51' - 4 3/4" B CA platform 19' - 3" platform 19' - 3" VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 21.60° 2 A-300 2 A-300 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" MECHANICAL CHASE Existing First Floor 20' - 0" Existing First Floor 20' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" Collar Tie (clg.) 51' - 4 3/4" Collar Tie (clg.) 51' - 4 3/4"2 31 4 platform 19' - 3" platform 19' - 3" VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 1 A-300 1 A-300 A-330 3 1 A-301 1 A-301 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 2 A-301 2 A-301 3 A-301 10' - 1 1/4" 1' - 6" This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:03 AM A-300 BUILDING SECTIONS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 Section 1 1/4" = 1'-0"2 Section 2 Page 26 of 86 Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" B CA platform 19' - 3" platform 19' - 3" 2 A-300 2 A-300 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 11' - 0" 121 1/4" 132" Existing First Floor 20' - 0" Existing First Floor 20' - 0" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" Collar Tie (clg.) 51' - 4 3/4" Collar Tie (clg.) 51' - 4 3/4" ROF 73' - 0" ROF 73' - 0" B platform 19' - 3" platform 19' - 3" VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 2 A-300 2 A-300 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" Foundation 16' - 5" Foundation 16' - 5" First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" BC A platform 19' - 3" platform 19' - 3" VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" 2 A-300 2 A-300 mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" Existing First Floor 20' - 0" Existing First Floor 20' - 0" This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:04 AM A-301 BUILDING SECTIONS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 Detail 0 1/4" = 1'-0"2 Section 3 1/4" = 1'-0"3 Section 4 Page 27 of 86 First Floor 17' - 9" First Floor 17' - 9" First Floor Plate 31' - 9" First Floor Plate 31' - 9" A VESTIBULE PLATE 33' - 9" VESTIBULE PLATE 33' - 9" FOOTING SEE STRUCTURAL FOR SLAB AND FOOTING DETAILS PROVIDE BLOCK LEDGE FOR CMU PRE-FABRICATED METAL BUILDING ROOF :ROOF TO HAVE 42" OVERHANG TYP. :8" MAX THICKNESS FOR FASCIA : SAG AND BAG OR EQUAL FIBERGLASS INSULATION TO IBC REQUIRED "R" VALUE PER METAL BUILDING SUPPLIER : ARCHITECT SHALL REVIEW AND APPROVE SHOP DRAWINGS PROVIDED BY METAL BUILDING MANUFACTURER PRIOR TO FABRICATION TYPICAL WALL ASSEMBLY : (3) COAT HARDCOAT STUCCO (TO MATCH EXISTING ADJACENT SANCTUARY BUILDING) OVER : DENS GLASS GOLD PANELS ON :COLD FORMED STEEL STUD FRAMING (BETWEEN Z GIRTS, FLUSH TO OUTSIDE) :INSTALL PER MFR. ON HORIZONTAL "Z" GIRTS : INSTALL "Z" GIRTS AS PER METAL BUILDING MANUFACTURER REQUIREMENTS : SAG AND BAG OR EQUAL FIBERGLASS INSULATION TO IBC REQUIRED "R" VALUE PER METAL BUILDING SUPPLIER : PREFABRICATED METAL BUILDING STRUCTURE. DETAILS PROVIDED BY MANUFACTURER : INTERIOR WALL FACE IS 1/2" GYPSUM WALLBOARD STEEL STRUCTURE BY OTHERS 3'-6" STEEL OVERHANG EXTENSION BY METAL BUILDING MANUFACTURER (RAKE & EAVES) 3' - 6" 1' - 0" 2' - 0" FOOTING NOTE: FOOTING IS 12" PROUD OF GRID LINE, TYP. CHAMPHER LAST 6" @ 15° AROUND PERIMETER 15.00° 0' - 6" 0' - 6" 14' - 0" 11 1/4" 9 1/4" 8 1/8" 20 27/32" 1 1/2" MATCH TYP. EAVE HEAVY TIMBER BEAM 8" THICK X 24X24 SHOP BUILT CEDAR/CYPRUS BRACKET PROVIDE SHOP DRAWINGS FOR ARCHITECT REVIEW PRIOR TO INSTALL WOOD MOUNTING PLATE mechanical mezzanine 28' - 9" mechanical mezzanine 28' - 9" 8X8 TIMBER OUTRIGGER 3 1/4" 5" 5" THRU BOLT TO METAL TAB PROVIDED BY P.E.M.B. MANUFACTURER PROVIDE SHOP DRAWINGS FOR ARCHITECT REVIEW PRIOR TO INSTALL This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:05 AM A-330 WALL SECTIONS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1 1/2" = 1' -0"1 TYPICAL WALL SECTION 1 1/2" = 1' -0"2 BRACKETED SHED ROOF DETAIL 1 1/2" = 1' -0"3 Section 2 - Callout 1 Page 28 of 86 This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:06 AM A-331 STEEPLE The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1" = 1'-0"1 STEEPLE Page 29 of 86 DOUBLE GLASS INTERIOR DOOR 7' - 0" 6' - 0" 3' - 0" 6' - 8" 36X80 FLUSH PANEL INTERIOR DOOR 2' - 6" 6' - 8" 30X80 FLUSH PANEL INTERIOR DOOR 36X80 FLUSH PANEL INTERIOR DOOR W/ VISON PANEL 3' - 0" 6' - 8" 25" 5" 9 1/2" 26" 8" 35 3/8" 4 5/8" 80" 36" 6" 24" 6" 6" 24"6" NOTE: ALL INTERIOR DOORS ARE PREFINISHED SOLID CORE WOOD DOORS IN HOLLOW METAL FRAMES INSTALL IN ACCORDANCE WITH Hollow Metal Manufacturers Association Division (HMMA) of the National Association of Architectural Metal Manufacturers (NAAMM) AND INSTALL PER ANSI AND NAAMN STANDARDS FOR HOLLOW METAL DOOR FRAMES 13' - 0" 2' - 0" 8' - 0" 2' - 0" 40" 8" 108" 3' - 4" 9' - 0" FIXED GLASS TRANSOMS WOOD TRIM TO MATCH DOOR FINISH FIXED GLASS IN SOLID WOOD FIXED SIDELIGHT SOLID WOOD DOORS STRUCTURAL MULL - TRIM TO MATCH PROVIDE ADA THRESHOLDS, CLOSER, FIRE EXIT SIGNAGE & PANIC HARDWARE ON ALL OPERABLE EXTERIOR DOORS (EXCEPT RISER ROOM DOOR) 96" 5" 67" 24" 5" 26" 5" 8" 6 3/4" 9 1/4" SOLID WOOD DOOR WITH FIXED GLASS STUCCO ON FOAM TRIM STEEL DOOR STUCCO This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:07 AM A-401 DOOR & WINDOW SCHEDULES The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA DOOR SCHEDULE -EXTERIOR DESCRIPTION DOOR CONSTRUCTION HARDWARE TRIM MATERIALS PERFORMANCE CommentsMark Door Panel Type Operation Number of Leafs Door Slab Shape Panel Shape Panel Layout (Horiz/Vert) Divided Lites (High/Wide) Transom Lites (High/Wide)Room to Room Door Slab Size; Width x Height x Thickness Transom Width x Height Lock Rail Height Jambs (Width x Thickness) Frame Assembly Size (W x H) Rough Opening (WxH) {calculated from subloor) Square Top Frame Segment Archtop Frame Circle Top Frame Structural Mull Height Vertical Structural Mull Floor Clearance Finish Floor Thickness Threshold Thickness Undercut Exterior Handle Interior Handle Lock and Latches Hinges Ironmongery Notes EXT CASE INT CASE Door Slab Material Style and Rail Material Panel Material Glass Material Muntin Material Door Frame Material Threshold Type Exterior Casing Material Structural Mullion Material Interior Casing Material THERMAL DP Rating Fire Rating SHGC Orientation Panel Area (SQ. FT.) R Value U Factor E101 Full Panel with Transom DOUBLE SWING 2 S PS 2 / 1 1 / 1 1 / 1 from:VESTIBULE 48" x 108" x1 3/4" 48"x40" 8" 6 9/16" x 3/4" 97.5"x 156" 98" x 158 1/4" Yes No No 8" No 1/2" 3/4" 3/4" 1 1/4" Wood Wood Wood Glass Wood Wood Wood Wood Wood .19 36.00 2 .40 55 E101A Full Glass with Transom SINGLE SWING 1 S PS 1 / 1 1 / 1 1 / 1 from:VESTIBULE 24" x 108" x1 3/4" 24"x40" 8" 6 9/16" x 3/4" 25.5"x 156" 26" x 158 1/4" Yes No No 8" No 1/2" 3/4" 3/4" 1 1/4" Wood Wood Wood Glass Wood Wood Wood Wood Wood .19 18.00 2 .40 55 E101B Full Glass with Transom SINGLE SWING 1 S PS 1 / 1 1 / 1 1 / 1 to:VESTIBULE 24" x 108" x1 3/4" 24"x40" 8" 6 9/16" x 3/4" 25.5"x 156" 26" x 158 1/4" Yes No No 8" No 1/2" 3/4" 3/4" 1 1/4" Wood Wood Wood Glass Wood Wood Wood Wood Wood .19 18.00 2 .40 55 E106 Panel and Glass - SINGLE SWING 1 S PS 1 / 1 1 / 1 1 / 1 from:HALL 36" x 96" x1 3/4" 36"x18" 8" 6 9/16" x 3/4" 37.5"x 96" 38" x 98 1/4" Yes No No 1 1/2" No 1/2" 3/4" 3/4" 1 1/4" Wood Wood Wood Glass Wood Wood Wood Wood Wood .19 24.00 2 .40 55 E116 Panel and Glass - SINGLE SWING 1 S PS 1 / 1 1 / 1 1 / 1 from:HALL 36" x 96" x1 3/4" 36"x18" 8" 6 9/16" x 3/4" 37.5"x 96" 38" x 98 1/4" Yes No No 1 1/2" No 1/2" 3/4" 3/4" 1 1/4" Wood Wood Wood Glass Wood Wood Wood Wood Wood .19 24.00 2 .40 55 E123 E124 E125 from:SANCTUARY to:MEN'S RESTROOM E128 Full Panel - SINGLE SWING 1 S PS 1 / 1 1 / 1 1 / 1 from:RISER 36" x 96" x1 3/4" 36"x18" 8" 6 9/16" x 3/4" 37.5"x 96" 38" x 98 1/4" Yes No No 1 1/2" No 1/2" 3/4" 3/4" 1 1/4" Steel DS 1 Steel G1 DS 1 Wood Wood DF 1 TR 2 .19 24.00 2 .40 55 FLUSH PANEL EXTERIOR STEEL DOOR Grand total: 9 Window Schedule Mark (#) Mulled Units Type Window Width (Unit) Window Height (Unit -w/o Transom) Head Height Glass Area R Value U Factor DP RatingComments 101 (1) Single Fixed 3' - 0" 7' - 0" 8' - 4 5 /16" 16 SF 102 (1) Single Fixed 3' - 0" 7' - 0" 8' - 4 5/16" 16 SF 107 (1) Single Fixed 3' - 0" 5' - 0" 9' - 0" 11 SF 108 (1) Single Fixed 3' - 0" 5' - 0" 9' - 0" 11 SF 109 (1) Single Fixed 3' - 0" 5' - 0" 9' - 0" 11 SF 111 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF 112 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF 113 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF 115 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 116 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 119 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 120 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 121 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 122 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 123 (1) Single Fixed 3' - 0" 5' - 0" 6' - 8" 11 SF 124 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF 125 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF 126 (1) Single Fixed 3' - 0" 7' - 0" 9' - 0" 16 SF Grand total: 18 237 SF Room Schedule Number Name Level Area Perimeter Floor Finish Base Finish Base Offset Wall Finish Ceiling Finish Volume Comments 010 SANCTUARY First Floor 2687 SF 215' - 10 29/32" CARPET 0 ' - 0" 21975.75 CF 011 MULTI-PURPOSE ROOM First Floor 144 SF 49' - 7" CARPET 0' - 0" 1452.49 CF 014 HALL First Floor 378 SF 162' - 10" CARPET 0' - 0" 4252.04 CF 018 VESTIBULE First Floor 169 SF 52' - 7" 0' - 0" 2371.25 CF 021 ADMINISTRATIVE First Floor 84 SF 38' - 11" CARPET 0' - 0" 830.81 CF 024 SOUND PLATFORM First Floor 85 SF 42' - 2 31/32" WOOD 0' - 0" 1015.63 CF 025 MEN'S RESTROOM First Floor 187 SF 70' - 5 7/8" 0' - 0" 1938.08 CF 026 WOMEN'S RESTROOM First Floor 196 SF 70' - 5 7/8" 0' - 0" 2027.65 CF 027 CLOSET First Floor 6 SF 10' - 8 13/32" 0' - 0" 87.67 CF 028 CLOSET First Floor 6 SF 10' - 3 1/4" 0' - 0" 81.89 CF 029 BATHROOM First Floor 45 SF 28' - 4" 0' - 0" 449.26 CF 030 PASTOR OFFICE First Floor 129 SF 46' - 4" CARPET 0' - 0" 1288.48 CF 034 MOP First Floor 8 SF 11' - 4" 0' - 0" 77.40 CF 035 ADA RESTROOM First Floor 67 SF 33' - 1" 0' - 0" 664.64 CF 036 RISER First Floor 43 SF 26' - 4" 0' - 0" 433.43 CF 037 ELECTRICAL First Floor 21 SF 20' - 5" 0' - 0" 216.71 CF DOOR SCHEDULE - INTERIOR DESCRIPTION Family and Type Height Width DESCRIPTION CommentsMark Room to Room 102 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0 " from:VESTIBULE to:MEN'S RESTROOM 103 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:WOMEN'S RESTROOM to:VESTIBULE 104 Door-Exterior-Double-Two_Lite: 72" x 84" 7' - 0" 6' - 0" from:VESTIBULE to:SANCTUARY 105 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:SANCTUARY to:HALL 109 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:HALL to:ADMINISTRATIVE 110 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:CLOSET to:HALL 111 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:SANCTUARY to:HALL 112 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:HALL to:PASTOR OFFICE 117 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:HALL to:SANCTUARY 123 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:MOP to:HALL 124 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:MULTI-PURPOSE ROOM to:HALL 125 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:ELECTRICAL to:HALL 126 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:ADA RESTROOM to:HALL D119 Door-Passage-Single-Vision_Lite: 36" x 80" 6' - 8" 3' - 0" from:HALL to:SANCTUARY D120 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" from:CLOSET to:HALL D121 Door-Passage-Single-Flush: 30" x 80" 6' - 8" 2' - 6" from:BATHROOM to:PASTOR OFFICE D124 Door-Passage-Single-Flush: 36" x 80" 6' - 8" 3' - 0" to:MEN'S RESTROOM Grand total: 17 1/4" = 1'-0" INTERIOR DOOR TYPES 1/4" = 1'-0"1 - ENTRY DOOR 1/4" = 1'-0"2 SIDE DOORS 1/4" = 1'-0"3 RISER ROOM DOOR 1/4" = 1'-0"5 TYPICAL WINDOW Page 30 of 86 AIR/WATER BARRIER FLEXIBLE FLASHING METAL FLASHING GYPSUM SHEATHING STEEL STUDS FLEXIBLE FLASHING HEAD FLASHING 5 1/2" CONTINUOUS AIR/WATER BARRIER WRAP WINDOW ROUGH OPENING WITH APPROPRIATE FLEXIBLE FLASHING MATERIAL. MAINTAIN A MINIMUM 3” FLEXIBLE FLASHING RETURN UNTO EACH ADJACENT SURFACE. STEEL STUD SPACING FOR STUCCO IS 16" O.C. INSTALL CEMENT PLASTER, LATH, AND ACCESSORIES INCLUDING CONTROL JOINTS IN ACCORDANCE WITH ASTM C 926 STANDARD SPECIFICATION FOR APPLICATION OF PORTLAND CEMENT-BASED PLASTER & ASTM C 1063 STANDARD SPECIFICATION FOR INSTALLATION OF LATHING AND FURRING TO RECEIVE INTERIOR AND EXTERIOR PORTLAND CEMENT-BASED PLASTER 2" 7 1/4" 1 1/8"7/8" 15.00° A-402 1 Sim GYPSUM SHEATHING CAVITY INSULATION COLD FORMED STEEL HEADER SEE STRUCTURAL FOR DESIGN STUCCO OVER RIGID FOAM TRIM 3 COAT HARDCOAT STUCCO OVER METAL LATHE INSULATION WINDOW UNIT WINDOW HEAD DETAIL WINDOW SILL DETAIL WINDOW JAMB DETAIL STUCCO OVER RIGID FOAM TRIM 3 COAT HARDCOAT STUCCO OVER METAL LATHE CONTINUOUS AIR/WATER BARRIER GYPSUM SHEATHING INTERIOR EXTERIOR INTERIOR EXTERIOR 2" 3 1/2" 2" 3 1/2" NOTE: DOOR HEADER AND JAMB FLASHING AND TRIM DETAILS ARE SIMILAR TO WINDOW HEAD AND JAMB DETAILS SILL PAN WINDOW FLASHING SEALANT GYPSUM SHEATHING AIR/WATER BARRIER SILL FLASHING TYPICAL STAINED GLASS INSERT FOR FULL HEIGHT WINDOWS ON INSIDE TYPICAL STAINED GLASS INSERT FOR TWO FRONT WINDOWS AT RESTROOMS ON INSIDE 100% OPAQUE GLASS IN BLACK ON BOTTOM PORTION PROVIDE SHOP DRAWINGS FOR REVIEW PRIOR TO INSTALL This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:08 AM A-402 DOOR & WINDOW DETAILS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 6" = 1'-0"1 HEAD FLASHING DETAIL 3" = 1'-0"3 WINDOW DETAILS 6" = 1'-0"2 WINDOW SILL FLASHING 1" = 1'-0"4 Stained Glass Window Detail Page 31 of 86 FIG. 702.3.3.1 LOCATION OF WALL-MOUNTED APPLIANCES (A) WALL ALARM (B) WALL ALARM WITH SMOKE DETECTOR FLOOR OR GROUND (100-305) (2030-2440) FLOOR OR GROUND (2030-2440) (CEILING HEIGHT > 9140) CEILING CEILING FIG. 702.3.3.2 LOCATION OF CEILING-MOUNTED APPLIANCES FIG. 702.3.5.1 APPLIANCE SPACING IN CORRIDORS (15-30m) (4570) (4570)(15-30m) (15-30m) FIG. 702.3.6.2 APPLIANCE LOCATION IN SLEEPING ROOMS (A) ONE BED (4880) (B) TWO BEDS FIG. 703.2.4.4 CHARACTER HEIGHT LIBRARY (16-51) FIG. 703.2.8 MOUNTING LOCATION AT DOORS (455) (455) PROTRUDING OBJECTS FIG. 307.3 POST-MOUNTED PROTRUDING OBJECTS (100) MAX. (305) MAX. (305) (X > 305) (X > 305) FIG. 307.2 LIMITS OF PROTRUDING OBJECTS (4570) (4880) CL 4"-12" 80"-96" 30' MAX. CEILING HEIGHT > 30' 15' MAX. 50'-100' 50'-100' 15' MAX.50'-100'15' MAX. 16' MAX. 16' MAX. 5/8"-2" 18" MIN.18" 4" MAX. X > 80" X > 27" X > 27" 80" MIN. 27" MAX. X > 12" X > 12" (X > 2030) (X > 685) (X >685) (685) 12" 12" COMMUNICATION ELEMENTS AND FEATURES (2030) _ _ (610) (610)(1320) (815) (915) CLEAR WIDTH OF AN ACCESSIBLE ROUTE 36" min. 32" min. 24" max.52" min.24" max. FIG. 404.2.4.1 (B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PUSH SIDE (G) LATCH APPROACH, PUSH SIDE(F) LATCH APPROACH, PULL SIDE (445) (305) (915) (1065) (610) (1370) (1065) (1370) (1525) (1525) (1065) (1220) (1220) (610) FIG. 404.2.4.2 MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS (A) FRONT APPROACH (B) POCKET OR HINGE APPROACH (C) STOP OR LATCH APPROACH FIG. 404.2.6 TWO DOORS IN A SERIES (A) (B) (1220) (1065) (1065) (610) (1370)(1220) (1220) (A) FRONT APPROACH, PULL SIDE DOORS AND DOORWAYS60" MIN. 18" MIN. 48" MIN. 36" MIN. 60" MIN. 42" MIN. 54" MIN. 42" MIN. 54" MIN. 48" MIN. 24" MIN.12" MIN. 24" MIN. 42" MIN 48" MIN. 48" MIN. 54" MIN. 48" MIN. 42"MIN. 42" MIN. 24" MIN. 10" 67" MIN.64" MIN. 38" MIN. 22" MIN. 11" MIN. 42" MIN. 11" 68" MIN. MIN. 36" MIN. 24" MIN. 16" MIN. 36" MIN. 16" 8" MIN. 8" MIN. 64" MIN. 40" MIN. 20" MIN. 12" MIN. 40" MIN. 12" SIZE OF WHEELCHAIR TURNING SPACE CLEAR FLOOR SPACE (A) FORWARD (B) PARALLEL FIG. 405.5 POSITION OF CLEAR FLOOR OR GROUND SPACE (760) (1220) (760) (1220) (A) FORWARD APPROACH (B) PARALLEL APPROACH FIG. 305.7 MANEUVERING CLEARANCE IN AN ALCOVE (915) (1525) (1220) (760) (X > 610) (X > 380) FIG. 306.3 KNEE CLEARANCE (205) (280) (685) (230) FIG. 306.2 TOE CLEARANCE (430) (230) FIG. 307.4 REDUCED VERTICAL CLEARANCE (685) (X < 2030) 48" MIN. 48" MIN. 30" MIN. 30" MIN. 48" MIN. 36" MIN. 60" MIN. 30" MIN. X > 15" X > 24" 27" MIN. 9" MIN. 8" MIN. 11" MIN. 9" MIN. 17" MIN. 27" MAX. X < 80" (380) (1220) FIG. 308.2.1 UNOBSTRUCTED FORWARD REACH FIG. 308.2.2 OBSTRUCTED HIGH FORWARD REACH (1220) (510) (510-635) (1220) (1220) (255) FIG. 308.3.1 UNOBSTRUCTED SIDE REACH FIG. 308.3.2 OBSTRUCTED HIGH SIDE REACH (610) (1170) REACH RANGES 15" MIN. 48" MAX. 48" MAX. 20" MAX. 44" MAX. (1120) 20" - 25" 48" MAX. 48" MAX. 10" MAX. 46" MAX. 24" MAX. FIG. 403.5.1 CLEAR WIDTH AT TURN (1065) (1065) (X < 1320) (1220) 42" min.42" min. 48" min. X < 52" CLEAR WIDTH AT TURN 60" 36" MAX 52" 36" ALTERNATE CLEAR WIDTH AT TURN 43" MAX 52" 43" ALTERNATE 43" 36" 36" 28" 28" 4" 4" 36" 36" 8" 8" 36" 44" 38" 42" (815) 90 (A) HINGED DOOR (815) (B) SLIDING DOOR (815) (C) FOLDING DOOR FIG. 404.2.3 CLEAR WIDTH OF DOORWAYS 32" min. 32" min. 32" min. TURNING AND PASSAGE CLEARANCES This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:09 AM A-601 ADA and ANSI Standard Details The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 ADA ANSI CLEARANCES Page 32 of 86 (1420) (405-455) (1525) (430-485) FIG. 604.5.2 REAR WALL GRAB BAR FOR WATER CLOSET FIG. 604.7 DISPENSER LOCATION (1065)(305) (1370) (380) (38) (180-230) (1220) (305)(610) (915) SIDE (1420) FIG. 604.8.1.1 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS (B) FLOOR-MOUNTED WATER CLOSET(A) WALL-HUNG WATER CLOSET(1420) (1525) 24" min. FIG. 604.8.3 TOILET COMPARTMENT DOORS (100) (1065) FIG. 606.3 HEIGHT OF LAVATORIES AND SINKS (865) FIG. 602.5 DRINKING FOUNTAIN SPOUT LOCATION (A) PARALLEL APPROACH (B) FORWARD APPROACH (380)(125) (90) (760) (760) (610) (305) 24" min. (380) 9" (230) (610) (230) (305) (610) FIG. 607.5 back wall seat wall control wall (915) (1220) (915) (915) (760) (1525) (760) (1220) (760) (915) (445) (150) (150) (150) (150) (150) FIG. 608.3.2 GRAB BARS IN ROLL-IN-TYPE SHOWERS (C) GRAB BARS IN ROLL-IN-TYPE SHOWERS (1220) FIG. 608.5 CONTROLS IN TRANSFER-TYPE control wall control wall (380) (A) (685) (B) back FIG. 608.6 LOCATION OF SHOWER SPRAY UNIT FIG. 609.3 SPACING OF GRAB BARS (38) (380) (380-405) (430-485) (430-485) FIG. 610.3.1 RECTANGULAR SHOWER COMPARTMENT SEAT FIG. 610.3.2 L-SHAPED SHOWER COMPARTMENT SEAT (75) (380-405) (38) (560-585) (380-405) (355-380)(64) (38) FIG. 604.2/604.3.1 WATER CLOSET LOCATION/ SIZE CLEARANCE FIG. 604.4/604.5.1 HEIGHT OF WATER CLOSET/ SIDE WALL GRAB BAR FOR WATER CLOSET FIG. 607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS (WITH FIG. 607.2 CLEARANCES) FIG. 607.4.2 GRAB BARS FOR BATHTUBS WITHOUT PERMANENT SEATS (WITH FIG. 607.2 CLEARANCES) FIG. 608.2.1/608.3.1 FIG. 608.2.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT FIG. 608.2.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT (A) STANDARD ROLL-IN-TYPE SHOWER (B) ROLL-IN-TYPE SHOWER WITH SEAT (1525) LOCATION OF BATHTUB CONTROLS TRANSFER-TYPE SHOWER COMPARTMENT WITH GRAB BARS *36" (915)mm MIN. WHEN WALL SPACE PERMITS head end foot end wall (64) (150) (150) (150) wall (305) foot end wall back wall back wall head end wall end wall (150) SHOWERS PLUMBING ELEMENTS AND FACILITIES 16"-18" 17"-19" 42" min.12" max. 60" min. 56" min. 54" min. 1 1/2" min. 7"-9"12" min. 36" min. TRANSFER 56" min. 60" min. 56" min. 60" min. 4" max. 48" min. 34" max. 15" max.5" max. 3 1/2" max. length of tub 30" min. 30" min. length of tub 15" max.12" max. 12" min. 24" min. 9" 24" max.12" max. 36" min.36" 48" min. 36" min. 60" min. 30" min.30" min. 36" min. 60" min. 36" 18" 6" max. 6" max. 6" max. 6" max. 6" max. 6" max 6" max. 6" max. 48" max. 15" max. 27" max. 15" min. 1 1/2" 15"-16" 17"-19" 17"-19" 2 1/2" max. 3" max. 15"-16" 11#2" max. 22"-23" 15"-16" 14"-15"2 1/2" max. 1 1/2" max.15" min. 48" max. 12" min. 6" max. wall CL CL CL CL 54" MAX. 40" MAX. 34" MAX. 1'-9" 3'-6" MIRROR INSUL. PIPES TOWEL DISPENSER 18" This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:10 AM A-602 ADA & ANSI DETAILS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 ADA ANSI PLUMBING Page 33 of 86 (2440) (1525) (2440) (6100) (1525) FIG. 503.3 PASSENGER LOADING ZONE ACCESS AISLE (1525)(1525) LANDING AT LEAST AS WIDE AS RAMP RUN LANDING (A) FIG. 405.7 RAMP LANDINGS (1525)LANDING RAMP RUN RAMP RUN RAMP RUN (B) FIG. 407.2.2 ELEVATOR CALL BUTTONS FIG. 407.2.3.2.1 HEIGHT OF ELEVATOR VISIBLE SIGNALS (890-1220) (1830) FIG. 406.12 ISLANDS (A) CUT THROUGH AT ISLAND (B) CURB RAMP AT ISLAND (1220) (305) (305) (A) EXTENDED SURFACE FIG. 405.9 RAMP EDGE PROTECTION (B) CURB OR BARRIER (X < 100) (X < 100) FIG. 406.3 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS 12 11 20 ADJOINING SURFACE MAXIMUM SLOPE CURB RAMP MAXIMUM SLOPE (1220) (A) (B) (X < 1220) FIG. 406.4 SIDES OF CURB RAMPS RETURNED CURB (C) PLANTING AREA PLANTING AREA (A) (1220) (B) FIG. 406.11 DIGINAL CURB RAMPS FIG. 502.2/502.3 VEHICLE PARKING SPACE/ PARKING SPACE ACCESS AISLE ACCESS AISLE SERVING VAN PARKING SPACESACCESS AISLE SERVING CAR PARKING SPACES (1525) FLARED SIDES 1:10 MAX. SLOPE FLARED SIDES 1:12 MAX. SLOPE (915) GENERAL SITE AND BUILDING ELEMENTS 96" MIN. 60" MIN.FULL LENGTH OF PARKING SPACE 96" MIN. 20' MIN. 60" MIN. 60" min. 60" min. 60" min. 35"-48" 72" min. 36" min. 48" min. 12" min. 12" min. X < 4" X < 4" 48" min. X < 48" 48" min. 60" min. AREA TO BE MARKED PLANTING AREA PLANTING AREA (1220)48" min. AREA TO BE MARKED AREA TO BE MARKED CL CL (A) VERTICAL RISER (B) CURVED NOSING (C) BEVELED NOSING (D) ANGLED RISER RADIUS 1/2" MAX. TYP. 30 max. beveled FIG. 504.5 STAIR NOSINGS FIG. 504.2 TREADS AND RISERS FOR ACCESSIBLE STAIRWAYS(100-180) (A) STAIRS (865-965) (B) RAMPS (865-965) FIG. 505.7 HANDRAIL CROSS SECTION FIG. 505.4 HANDRAIL HEIGHT (38) FIG. 505.5 HANDRAIL CLEARANCE (A) CIRCULAR 4"-6 1/4" PERIMETER (100-160) FIG. 505.10.1 TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS (305) (305) FIG. 505.10.2 TOP HANDRAIL EXTENSIONS AT STAIRS (305) X = TREAD DEPTH FIG. 505.10.2 BOTTOM HANDRAIL EXTENSIONS AT STAIRS (B) NON-CIRCULAR (C) NON-CIRCULAR BUILDING BLOCKS MAX. (6.4) 2 FIG. 303.2 VERTICAL CHANGES IN LEVEL FIG. 303.3 BEVELED CHANGES IN LEVEL 1 FIG. 302.3 OPENINGS IN FLOOR OR GROUND SURFACES UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH LONG DIMENSION PERPENDICULAR TO DIRECTION OF TRAVEL (280) (57)(32-51) (38) (13) curved (13) 1 1#2" MAX. 1 1/2" MAX. 11" MIN. 34"-38" 34"-38" 1 1/2" MIN." 1 1/4"-2" 2 1/4" MAX. 12" MIN. 12" MIN. X12" MIN. X 1/4" 1/4" -1/2" (6.4-13) 1/2" MAX. 4" MIN.-7" MAX. This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:11 AM A-603 ADA & ANSI DETAILS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1/4" = 1'-0"1 ADA ANSI SITE STAIRS AND RAMPS Page 34 of 86 This sheet is NOT valid for permit or construction unless signed by the Architect above. © 2022 843.290.3076 email: mikevaccaro7@yahoo.com PRINT DATE www.VaccaroArchitecture.com FOR: V A C C A R O ARCHITECTURE, INC. www.VaccaroArchitecture.com T A B C D E F G H J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C D E F G H J K L 10/29/2025 11:20:27 AM A-700 3D VIEWS The Historic First African Baptist Church 70 BEACH CITY ROAD, HILTON HEAD ISLAND, SOUTH CAROLINA 1 AXON Page 35 of 86 SSSS SSSS0+00 1+00 1+72SS 0+50 1+50 WWWWWWWWWWWWW 0+00 1+00 2+00 3+003+22 0+50 1+50 2+50 WWWWWW SS-CO SS-CO SS-CO WMWMWWWWWWWWWWWWWW LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD 16 1717 18 1818 18 17 15141616 1816 16 1717 16 SDSDSDSDSD SD SDSDSDSD RESTROOMRESTROOM SANCTUARY RESTROOMRISERROOM VESTIBULE FIRST AFRICAN BAPTIST CHURCH62' x 72' (4,560 SF)18.25' FFE STAGE OFFICERESTROOMOFFICEOFFICE LS TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE DRIP LINE90" LO DRIP LINE36" SYC DRIP LINE40" GUM DRIP LINE75" LO TPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPF TPFTPFTPF TPFTPFTPF TPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPF TPFTPFTPFTPF#4 WO 30" #3 SYC 36"#2 SYC 23"#1 LA 26"#9 LO 90"#10 LO 75" #15 WO22/22"#16 PN 8"#7 PN 10"#21 LO 8"#19 PN 24"#18 LO 16"#20 PN 18"#22 PN 22"#51 GUM16"/16"#52 GUM 14"#53 PN20"/10"#38 HIC 10"#39 LO 26"#47 GUM 40"#48 WO 10"#49 WO 8"#50 MAP 10"#55 WO 14"#54 WO 16"#56 WO 14"#57 WO 20"#58 LO 12"#61 LO 20"/14"#59 LO 15"#62 LO 8"#63 LA 22"#60 LO 16"#65 LO 7"#64 LO 7"#66 WO 10"#67 PN 20"#68 LO 24"#69 LA 18"#70 GUM 11"/11"#71 WO 14"#74 LA 22"#72 GUM 10"/8"/6"#73 PN 20" #43 LO 24"#43 HIC 18"#44 LO 20"#45 HIC 24"#46 LO 22"#41 HIC 20"/7"#42 HIC 15"#34 HIC 20"#33 GUM 12"#32 GUM 18"#31 LO 12"#30 LO 75"#29 LO 30" DRIP LINE75" LO LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD #5 PLM 13" #28 CHY 18" #36 LO 30"#27 PLM 13"#25 WO 20"#26 WO 16"#24 WO 12"#23 HIC 11"#14 WO 20"#13 WO 10"/6"#12 WO 16"#35 PLM 11"#11 LO 30"#6 PLM 20"#7 PLM 20"#8 PLM 20" #37 PLM 12" L.1SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call R LOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. JMJMBWDATE:JOB NUMBER:SC 6782-2501FIRST AFRICAN BAPTIST CHURCH70 BEACH CITY RD.PERMIT PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 OCTOBER 30, 2025SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INC 10/30/25 TREE TO REMAINSPECIMEN TREETO REMAINTREE TO REMOVE SIGNIFICANT TREETO REMAIN SIGNIFICANT TREETO REMOVE TREE LEGEND TPFTREE PROTECTION FENCELODLIMITS OF DISTURBANCE 020SCALE: 1"=20' BEACH CITY RD ENTERPRISE LN TOTAL SITE AREA:1.56 ACIMPERVIOUS AREA:0.73 ACPERVIOUS AREA:0.83 ACACI REQUIRED:747 (0.83 AC X 900 ACI)EXISTING ACI:1,258.50 ACIREMOVED ACI:235 ACITOTAL ACI:1,023.50 ACIPRE-DEVELOPMENT & POST-DEVELOPMENT ACI IS GREATER THAN THEREQUIRED 747 ACI, THEREFORE NO RECOMPENSE IS REQUIRED. TREE ACI CALCULATIONS TPF Page 36 of 86 SSSS SSSS SS WWWWWWWWWWWWW WWWWWW SS-CO SS-CO SS-CO WMWMWWWWWWWWWWWWWW LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD SDSDSDSDSD SD SDSDSDSD RESTROOMRESTROOM SANCTUARY RESTROOMRISERROOM VESTIBULE FIRST AFRICAN BAPTIST CHURCH62' x 72' (4,560 SF)18.25' FFE STAGE OFFICERESTROOMOFFICEOFFICE LS #4 WO 30" #3 SYC 36"#2 SYC 23"#1 LA 26"#9 LO 90"#10 LO 75" #15 WO22/22"#16 PN 8"#7 PN 10"#21 LO 8"#19 PN 24"#18 LO 16"#20 PN 18"#22 PN 22"#51 GUM16"/16"#52 GUM 14"#53 PN20"/10"#38 HIC 10"#39 LO 26"#47 GUM 40"#48 WO 10"#49 WO 8"#50 MAP 10"#55 WO 14"#54 WO 16"#56 WO 14"#57 WO 20"#58 LO 12"#61 LO 20"/14"#59 LO 15"#62 LO 8"#63 LA 22"#60 LO 16"#65 LO 7"#64 LO 7"#66 WO 10"#67 PN 20"#68 LO 24"#69 LA 18"#70 GUM 11"/11"#71 WO 14"#74 LA 22"#72 GUM 10"/8"/6"#73 PN 20" #43 LO 24"#43 HIC 18"#44 LO 20"#45 HIC 24"#46 LO 22"#41 HIC 20"/7"#42 HIC 15"#34 HIC 20"#33 GUM 12"#32 GUM 18"#31 LO 12"#30 LO 75"#29 LO 30" (1) QV (1) QV (1) CR (1) CR (8) SB (10) SB (17) IP (15) IP (136) TA (5) IN SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call R LOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. JMJMBWDATE:JOB NUMBER:SC 6782-2501FIRST AFRICAN BAPTIST CHURCH70 BEACH CITY RD.PERMIT PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 OCTOBER 30, 2025SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INC 10/30/25 020SCALE: 1"=20' BEACH CITY RD ENTERPRISE LN SYMBOLCODEBOTANICAL NAMECOMMON NAMESIZECONTAINERQTY TREESQVQUERCUS VIRGINIANASOUTHERN LIVE OAK3.5" CAL.B&B2 SHRUBSCRCYCAS REVOLUTASAGO PALM7 GAL.POT2 INILEX VOMITORIA 'NANA'DWARF YAUPON HOLLY3 GAL.POT5 SBSPARTINA BAKERISAND CORDGRASS3 GALPOT18 SYMBOLCODEBOTANICAL NAMECOMMON NAMESIZECONTAINERSPACINGQTY GROUND COVERSIPIRIS PRISMATICABLUE FLAG IRIS1 GAL.POT18" o.c.32 TATRACHELOSPERMUM ASIATICUMASIATIC JASMINE1 GAL.POT12" o.c.409 PLANT SCHEDULE L.2 Page 37 of 86 SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call R LOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. JMJMBWDATE:JOB NUMBER:SC 6782-2501FIRST AFRICAN BAPTIST CHURCH70 BEACH CITY RD.PERMIT PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 OCTOBER 30, 2025SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INC 10/30/25 6"(MIN.)4"12' MIN.(TYP)TAMP TO PREVENTSETTLING. REMOVE TOP 1/3OF BURLAP MULCH PLANTING MIX SPACE AS SHOWN ON PLANS SECTION1. LAYOUT PERIMETER PLANTING AS PER SPACING SHOWN ON PLANS.2. FILL IN PLANTING BED WITH STAGGERED SPACED PLANTING.PLANTYPICAL SHRUB PLANTINGN.T.S.2P-CO-PLA-04 12"Min.6"Min.6"Min.COMPACTED PLANTING MIX2'Min.PREPARED PLANTING MIX2"X2"X3' STAKETWINE @ 12" O.C.WRAP TRUCKTURN BUCKLE(TYPICAL)2 STRANDS 12 GUAGE WIRE(TYP.)1"X4"X10" WHITE WOOD FLAGFINISHED GRADESAUCER OF PLANTINGMIX TO HOLD WATER2"X2" STAKERUBBER HOSE REMOVE TOP 1/3 OF BURLAPNOTESMULCH WITH 3" OF CLEAN PINE STRAW. PREPARED PLANTING MIXLIMIT OF MULCHBERMTURN BUCKLE (TYPICAL)2"X2"X3' STAKE 2"X2" STAKE 2 STRANDS OF 12 GUAGEWIRE (TYPICAL) 1.2.TREES EIGHT FEET HIGH (8') OR LESS SHALL BE STAKED.TREES TALLER THAN EIGHT FEET (8') SHALL BE GUYED.3. 12"Min. TYPICAL TREE PLANTING & STAKINGN.T.S.1P-CO-PLA-05 GROUNDCOVER3/4" = 1'-0" PLAN SECTION VIEWEQ.EQ. 1234567 2-3" THICK LAYER OF MULCH1FINISHED GRADE2MODIFIED SOIL. DEPTH VARIES. (SEESPECIFICATIONS FOR SOILMODIFICATION).3EXISTING SOIL4GROUNDCOVER PLANTS TO BETRIANGULARLY SPACED5MULCH6PAVEMENT7NOTES:1- SEE PLANTING LEGEND FOR GROUNDCOVER SPECIES, SIZE, AND SPACING DIMENSION.2- SMALL ROOTS (1/4" OR LESS) THAT GROW AROUND, UP, OR DOWN THE ROOT BALL PERIPHERY ARE CONSIDERED ANORMAL CONDITION IN CONTAINER PRODUCTION AND ARE ACCEPTABLE HOWEVER THEY SHOULD BE ELIMINATEDAT THE TIME OF PLANTING. ROOTS ON THE PERIPHERY CAN BE REMOVED AT THE TIME OF PLANTING. (SEE ROOT BALLSHAVING CONTAINER DETAIL).3- SETTLE SOIL AROUND ROOT BALL OF EACH GROUNDCOVER PRIOR TO MULCHING.URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USE 6" MIN 3FX-PL-FX-GROU-01 L.3 CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA.SEE TREE PRESERVATION PLAN FOR FENCE ALIGNMENT.4'-0"MAINTAIN EXISTING GRADE WITHTHE TREE PROTECTION FENCEUNLESS OTHERWISE INDICATEDON THE PLANS.2" X 6' STEEL POSTS ORAPPROVED EQUAL.5" THICK LAYER OF MULCH. NOTES:1- SEE SPECIFICATIONS FOR ADDITIONAL TREEPROTECTION REQUIREMENTS.2- IF THERE IS NO EXISTING IRRIGATION, SEESPECIFICATIONS FOR WATERING REQUIREMENTS.3- NO PRUNING SHALL BE PERFORMED EXCEPTBY APPROVED ARBORIST.4- NO EQUIPMENT SHALL OPERATE INSIDE THEPROTECTIVE FENCING INCLUDING DURING FENCEINSTALLATION AND REMOVAL.5- SEE SITE PREPARATION PLAN FOR ANYMODIFICATIONS WITH THE TREE PROTECTIONAREA. SECTION VIEWKEEP OUTTREE PROTECTIONAREA8.5" X 11" SIGNLAMINATED INPLASTIC SPACEDEVERY 50' ALONGTHE FENCE. URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USE TREE PROTECTION FENCE: HIGHDENSITY POLYETHYLENE FENCINGWITH 3.5" X 1.5" OPENINGS; COLOR-ORANGE. STEEL POSTSINSTALLED AT 8' O.C. TREE PROTECTION3/16" = 1'-0"4FX-PL-FX-TRMT-02 Page 38 of 86 Page 39 of 86 Page 40 of 86 Page 41 of 86 Page 42 of 86 Page 43 of 86 Page 44 of 86 Page 45 of 86 Page 46 of 86 Page 47 of 86 Page 48 of 86 Page 49 of 86 Page 50 of 86 Page 51 of 86 Page 52 of 86 Page 53 of 86 Page 54 of 86 Page 55 of 86 Page 56 of 86 Page 57 of 86 Page 58 of 86 Page 59 of 86 Page 60 of 86 Page 61 of 86 Page 62 of 86 Page 63 of 86 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 70 Beach City Road – First African Baptist Church DRB-001095-2025 DATE: 11/25/2025 CATEGORY: Final RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 64 of 86 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Landscape plan Page 65 of 86 3 Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Final submittal for 70 Beach City Road, First African Baptist Church with the following conditions: 1. Any additional information as required by the Board. Page 66 of 86 Page 67 of 86 Town of Hilton Head Island Community Development Department One Town Center Court FOR OFFICIAL USE ONLY Hilton Head Island , SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www .hiltonheadislandsc.gov Applicant/Agent Name: Christy Chapman Company: Pulley Stu Date Received: Accepted by: ORB #: Meeting Date: dios Mailing Address: 117 Abel Peterson Drive Telephone: 704.336.9863 Fax: ------- tate: NC City: Mount Holly s E-mail: christy@withpu lley.com Zip: 28120 Project Name: Chase - Hilton Head Island Project Address: 2 Lafayette Pl, H ilton Head Island, SC 29926 Parcel Number [PIN]: R_§__10-008-000-0409-0000. Zoning District: --~M~a=in~S~t~re~e~t~D~is~tr~ic~t~--Overlay District(s): __ C_O_D __ CORRIDOR REVIEW, MAJOR DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUI Digital Submissions may be accepted via e-mail by calling 843-341-4 757. Project Category: REMENTS _ _ Concept Approval - Proposed Development __ Final Approval - Proposed Development Addition X Alteration/ _x_ Sign Submittal Requirements for All projects : a project is within the ion per LMO Section 16- _x_ Private Architectural Review Board (ARB) Notice of Action (if applicable) : When jurisdiction of an ARB, the applicant shall submit such ARB 's written notice of act 2-103.I.4.b.iii.0l. Submitting an application to the ARB to meet this requirement i s the responsibility of the applicant. osed Development $17 5, _L Filing Fee: Concept Approval-Proposed Development $175, Final Approval - Prop Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island. Additional Submittal Requirements : Concept Approval - Proposed Development __ A survey (1 "=30' minimum scale) of property lines, existing topography and the loc ation of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location ofbord ering streets, marshes and beaches. __ A site analysis study to include specimen trees, access, significant topography, wetl ands, buffers, setbacks, views, orientation and other site features that may influence design. __ A draft written narrative describing the design intent of the project, its goals and ob ~ectives and how it reflects the site analysis results. __ Context photographs of neighboring uses and architectural styles. __ Conceptual site plan (to scale) showing proposed location of new structures, parkin __ Conceptual sketches of primary exterior elevations showing architectural character development, materials, colors, shadow lines and landscaping . La~1 Revised O I 21/15 g areas and landscaping. of the proposed 1 == Page 68 of 86 Additional Submittal Requirements: Final Approval - Proposed Development ____L A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3. _x_ Final site development plan meeting the requirements of Appendix D: D-6.F. __x_ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.1. _____x_ Final floor plans and elevation drawings ( l/8 "= l '-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. ~ A color board (11 "x 17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation . ___x_ Any additional information requested by the Design Review Board at the time of concept approval , such as scale model or color renderings , that the Board finds necessary in order to act on a final application . Additional Submittal Requirements: Alterations/ Additions _____x_ All of the materials required for final approval of proposed development as listed above, plus the following additional materials . _x_ A survey (l "=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable , location ofborde ring streets, marshes and beaches. __x_ Photographs of existing structure. Additional Submittal Requirements: Signs ____L Accurate color rendering of sign showing dimensions , type of lettering, materials and actual color samples. For freestanding signs: _x_ Site plan (l "=30 ' minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _J(_ Proposed landscaping plan. For wall signs: _x_ Photograph or drawing of the building depicting the proposed location of the sign. _x_ Location , fixture type, and wattage of any proposed lighting. Note: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23. A representative for each agenda item is strongly encouraged to attend the meeting. Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. DYES [R]NO To the best of my knowledge, the information on this application and all additional documentation is true, factual, and complete. I hereby agree to abide by all conditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall apply to the subject property only and are a right or obligation transferable by sale. I further understand that in the event of a State of Emergency due to a Disaster, the review and approval times set forth in the Land Management Ordinance may be suspended. 11/12/2025 SIGNATURE DATE Last Rev1st:d O I 21 /15 2 == == == = = Page 69 of 86 Page 70 of 86 A00.0DESIGN REVIEW BOARDPACKAGECOVER SHEET Hilton Head - Design Review Board ARCHITECTURAL DRAWINGSFURNITURE FLOOR PLAN DESIGN REVIEW BOARD PACKAGE COVER SHEETBUILDING RENDERINGS LOCATION MAPSHEET INDEX BUILDING FLOOR AREA = 8,200 SF JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926CHASE # 48100R024455Version 20.7 SCOPE OF WORKEXTERIOR SITE: GENERAL CLEAN UP OF EXISTING FOLIAGE, INCLUDING TRIMMING TREES AND EXISTING BRUSH. MILL AND OVERLAY EXISTING SITE, PROVIDE HEAVY DUTY CONCRETEAT SELECT AREAS. REMEDIATE EXISTING SIDEWALKS FOR ADA COMPLIANCE FROM ENTRIES AND EXITS TO ADA PARKING STALLS. REMEDIATE ADA PARKING STALLS FOR COMPLIANCE.REPLACE ALL LIGHT POLES INCLUDING FIXTURES AND ADD NEW POLES TO IMPROVE LIGHT LEVELS ON SITE. WHERE DRIVE-UP CANOPY STRUCTURE IS REMOVED, PROVIDE NEW CURB ISLANDWITH XERISCAPE LANDSCAPPING. PROVIDE NEW CURB CUTS AND PAD FOR DUMPSTER ENCLOSURE.EXTERIOR BUILDING: REMOVE EXISTING DRIVE-UP CANOPY AND REPLACE WITH HIP ROOF TO MATCH EXISTING ROOF. REMOVE DORMERS AND (3) BARREL VAULT ROOFS. REPLACE ROOFNEW ASPHALT SHINGLES AND INFILL WITH BUILT UP GABLE ROOF WHERE BARREL VAULTS REMOVED. REPLACE ALL WINDOWS AND CURTAIN WALLS. REMOVE UTILITY YARD FENCE ANDREPLACE WITH NEW TREX COMPOSITE FENCING TO SCREEN HVAC EQUIPMENT. PROVIDE NEW AIR INTAKE AND EXHAUST LOUVERS NEAR THE MECHANICAL YARD. REMOVE EXISTING FENCEAND PROVIDE NEW STUCCO + CMU DUMPSTER ENCLOSURE. REMOVE DRIVE-UP WINDOW AND ASSOCIATED EQUIPMENT, REPLACE WITH WALL INFILL TO MATCH ADJACENT EXISTING WALLSAND INSTALL THRU-WALL ATM AND AHD. REPAINT AND PATCH EXISTING EIFS FINISHES AND PLASTER COLUMNS. BUILDING RENDERINGS A00.4A00.5DUMPSTER RENDERINGS 11-12-2025 DRB SUBMISSION 1A00.1A00.0A00.3 SITE AREA = 109,025 SF KEY SITE PLAN (FOR REFERENCE ONLY. SEE CIVIL) A00.6EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS N N LV A00.2 JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822DUMPSTER ENCLOSUREATM DRIVE-UPBUILDING A00.7A00.8BUILDING RENDERINGS BUILDING RENDERINGS CIVIL DRAWINGSSITE PLANC-301LANDSCAPE PLANL-101 HVAC ENCLOSURE PROJECT LOCATION EXISTING CONDITIONS AND DEMOLITION PLANC-203CHASE ENTRYFUTURE TENANT ENTRY Page 71 of 86 1A00.7 1A00.8 2A00.8 2A00.7 FUTURE ADJACENTTENANT FE ELECELECELEC SO-LB SO-LB 34"34"F-SQ-A ACTIVEACTIVELG + WEL-M-WMINTEGRAL 55"L&S-DS-M 34" 34" L&S-DS-S 41"30"RS1F-SLM-A TF-LTF-R ARTWORK ARTWORK F-POR-A 34" SO-LB SO-LB LOCKERSCOATHOOKSCOATHOOKS 34"30" FUTURE FUTURE ELEC A00.1FURNITURE FLOOR PLANLV SCALEFURNITURE FLOOR PLAN3/16" = 1'-0"1N JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 Page 72 of 86 A00.2BUILDING RENDERINGSLV SCALEBUILDING RENDERINGSNTS1 JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 REMOVE BARREL VAULTROOF ASSEMBLYREPLACE ROOFREPLACE WINDOWSREMOVE DRIVE-UP RE-WORK ADA RAMPAND PARKINGREMOVE RAMP,INCORPORATE INTOLANDSCAPE AREAREPLACE CURTAINWALL Page 73 of 86 A00.3BUILDING RENDERINGSLV SCALEBUILDING RENDERINGSNTS1 JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 REMOVE BARREL VAULTROOF ASSEMBLYREPLACE ROOFREMOVE HVAC ENCLOSURE -REPLACE WITH TREXSECLUSIONS FENCEREMOVE DRIVE-UP REPLACE CURTAIN WALL Page 74 of 86 A00.4BUILDING RENDERINGSLV SCALEBUILDING RENDERINGSNTS1 JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 REMOVE BARREL VAULTROOF ASSEMBLYREPLACE ROOFREMOVE HVAC ENCLOSURE -REPLACE WITH TREXSECLUSIONS FENCEREMOVE DORMERREPLACE WINDOWS REPLACE CURTAIN WALL Page 75 of 86 A00.5BUILDING RENDERINGSLV SCALEBUILDING RENDERINGSNTS1 JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 REPLACE ROOFREMOVE DORMERREMOVE DRIVE-UPREPLACE WINDOWS INFILL DRIVE-UP WINDOWAND OPENING, INSTALLNEW ATM AND AHDREMOVE DRIVE LANESAND ISLANDS, REPLACEWITH LANDSCAPED AREA Page 76 of 86 1'-6"3'-0"3'-0"14'-0" 10'-8" BOLLARDS -PAINT EPT-3STL. ANGLE AS REQD. FORCASTER MOUNTING CONCRETE CURB- REFER TOCIVIL RECYCLING BYOTHERS PITCH 1/4"PER FT.ALL EXPOSED STEELCOMPONENTS SHALL BEHOT-DIPPED GALVANIZED,PRIMED AND PAINTEDDUMPSTER BYOTHERS REFER TO SITE PLAN FORLIMITS OF CONCRETE PAD FOUNDATION, SEESTRUCTURAL EXTERIOR FINISH MATERIALSTHIS SCHEDULE IS COMPREHENSIVE. NOT ALL LISTED ITEMS ARE USED IN THIS PROJECTRF-1ROOF FINISHMANUFACTURERCERTAINTEEDPRODUCTLANDMARK- ASPHALT SHINGLESCOLORCOBBLESTONE GRAYST-1STUCCO FINISHMANUFACTURERSTO CORP.COLORTO MATCH EPT-1FINISHSAND FINISHTR-1TRIM BOARDMANUFACTURERJAMES HARDIEPRODUCT5/4 HARDIE TRIM BOARD (SMOOTH)COLORPAINT TO MATCH EPT-2SIZE144" LENGTH X 7.25" WIDTH X 1" THICKNESSTR-2SOFFIT BOARDMANUFACTURERJAMES HARDIEPRODUCTHARDIE VENTED SOFFIT PANELSCOLORPAINT TO MATCH EPT-2SIZE144" LENGTH X 16" WIDTH X 0.25" THICKNESSEPT-1EXTERIOR PAINTMANUFACTURERBENJAMIN MOOREPRODUCTBM ULTRA SPEC EXTCOLORPAINT TO MATCH SW 7036 ACCESSIBLE BEIGEFINISHSEMI-GLOSSEPT-2EXTERIOR PAINTMANUFACTURERBENJAMIN MOOREPRODUCTBM ULTRA SPEC EXTCOLORPAINT TO MATCH SW 7008 ALABASTERFINISHSEMI-GLOSSEPT-3EXTERIOR PAINTMANUFACTURERBENJAMIN MOOREPRODUCTBM ULTRA SPEC EXTCOLORPAINT TO MATCH SW 7069 IRON OREFINISHSEMI-GLOSSEIFS-1EIFS PARAPET (DARK COLOR)MANUFACTURERSTO CORP. (OR APPROVED EQUAL)PRODUCTSTOTHERM PREMIER NEXTCOLORTO MATCH EPT-1FINISHMATCH EXISTINGEIFS-2EIFS PARAPET (LIGHT COLOR)MANUFACTURERSTO CORP. (OR APPROVED EQUAL)PRODUCTSTOTHERM PREMIER NEXTCOLORTO MATCH EPT-2FINISHMATCH EXISTINGDFS-1DIRECT-APPLY FINISH SYSTEMMANUFACTURERSTOPRODUCTSTOQUIK GOLDCOLORMATCH SHERWIN WILLIAMS SW 6995 SUPERWHITEFINISHSTOLIT 1.0 6'-0" ALL EXPOSED STEEL COMPONENTSSHALL BE HOT-DIPPED GALVANIZED,PRIMED AND PAINTED 4'-0" 6" STEEL ANGLE / PLATE ASREQD. FOR CASTERMOUNTINGPAINT INTERIOR WALLSCONCRETE FILLED 6"DIAMETER BOLLARD WITHCONCRETE WASH TO SHEDWATER.PAINT EPT-3 CONCRETE FOOTING ANDFOUNDATION 8" NOM. C.M.U.- REFER TOSTRUCTURAL ENGINEERINGDRAWINGSREINFORCED CONCRETE SLABON COMPACTED GRANULARBASE- REFER TO CIVILENGINEERING DRAWINGSSLOPEEPT-1 CORONADO STONE WALL CAP - WHITE(OR PAINTED TO MATCH EPT-2) 10" x18", PAINT TO MATCH EPT-2.S.S.ANCHORS @ 24" O.C. EPOXY SETAND FULLY GROUTED INTO STRUCTURE TYPICAL STUCCO 6MINGROUND LINE ST-1 T.O. SLABREFER TO CIVILSEE CIVIL FOR CONCRETEPAD BEYOND DUMPSTER 1/2" COMPRESSIBLEISOLATION JOINT PAINT GATE AND HARDWAREEPT-3 A00.6DUMPSTER RENDERINGSLV SCALEDUMPSTER PLAN3/8" = 1'-0"1 SCALEDUMPSTER ELEVATIONSNTS3JPM Chase Retail Banking Center2 Lafayette Place,Hilton Head Island, SC 29926Hilton HeadDesign Review Board PRINTED 11/12/2025 SHEET NUMBERSHEET TITLEPROJECT INFORMATION BLOCKCHECKED BY:DRAWN BY:DATE:JOB #:25400911-12-2025TN ISSUE/BYDATEDESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr.Suite 600Tampa, FL 33602P: 813-323-9233FL Lic#AR-0014752www.bdgllp.com Architect of Record:Christopher Kirschner, AIA, LEED APSC License No. 5822 NSCALEDUMPSTER SECTION3/4" = 1'-0"2 Page 77 of 86 FINISH FLOOR DATUM GABLE ROOF PEAK +25'-2" B.O. SOFFIT +12'-9" T.O. EXISTING WINDOW +8'-8" T.O. SLAB/FND. +0'-0" FINISH GRADE VARIES T.O. HIGH ROOF PEAK +35'-2" T.O. MED ROOF PEAK +31'- 3" GABLE ROOF SOFFIT +16'-9" NEW BUILT-UP GABLE ROOF TREX SECLUSIONS COMPOSITE FENCE 'WINCHESTER GREY' 7'-0" NEW STOREFRONT NEW ROOF AT DRIVE-UP EIFS-1 EPT-2 EPT-1 TR-1 RF-1 EIFS-1 TR-1 EPT-2EPT-2 EPT-2 EPT-1 EPT-1 RF-1 EPT-2 EPT-1 EPT-1 EPT-1 FINISH FLOOR DATUM B.O. SOFFIT +12'-9" T.O. WINDOW +8'-8" T.O. SLAB/FND. +0'-0" FINISH GRADE VARIES HIGH ROOF PEAK +35'-2" MED ROOF PEAK +31'- 3" ADDRESS NO SMOKING WITHIN 25 FEET OF BUILDING ENTRANCE Planning Investing Advice Banking Credit Cards Business Home Auto Private Client Branch Hours Mon-Fri 9:00 AM - 5:00 PM Sat 9:00 AM - 2:00 PM Sun Closed GABLE ROOF PEAK +25'-2" GABLE ROOF EAVE +16'-9" NEW BUILT-UP GABLE ROOF NEW ROOF AT DRIVE-UP NEW STOREFRONT NEW BUILT-UP GABLE ROOF EIFS-1 TR-1 RF-1 EPT-2 EPT-2EPT-2TYP. AT ALL WINDOW TRIM EPT-1EPT-2 EIFS-1 TR-1 RF-1 EPT-1 EPT-2 EPT-1 EPT-2 RF-1 EXTERIOR FINISH MATERIALS THIS SCHEDULE IS COMPREHENSIVE. NOT ALL LISTED ITEMS ARE USED IN THIS PROJECT RF-1 ROOF FINISH MANUFACTURER CERTAINTEED PRODUCT LANDMARK- ASPHALT SHINGLES COLOR COBBLESTONE GRAY ST-1 STUCCO FINISH MANUFACTURER STO CORP. COLOR TO MATCH EPT-1 FINISH SAND FINISH TR-1 TRIM BOARD MANUFACTURER JAMES HARDIE PRODUCT 5/4 HARDIE TRIM BOARD (SMOOTH) COLOR PAINT TO MATCH EPT-2 SIZE 144" LENGTH X 7.25" WIDTH X 1" THICKNESS TR-2 SOFFIT BOARD MANUFACTURER JAMES HARDIE PRODUCT HARDIE VENTED SOFFIT PANELS COLOR PAINT TO MATCH EPT-2 SIZE 144" LENGTH X 16" WIDTH X 0.25" THICKNESS EPT-1 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7036 ACCESSIBLE BEIGE FINISH SEMI-GLOSS EPT-2 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7008 ALABASTER FINISH SEMI-GLOSS EPT-3 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7069 IRON ORE FINISH SEMI-GLOSS EIFS-1 EIFS PARAPET (DARK COLOR) MANUFACTURER STO CORP. (OR APPROVED EQUAL) PRODUCT STOTHERM PREMIER NEXT COLOR TO MATCH EPT-1 FINISH MATCH EXISTING EIFS-2 EIFS PARAPET (LIGHT COLOR) MANUFACTURER STO CORP. (OR APPROVED EQUAL) PRODUCT STOTHERM PREMIER NEXT COLOR TO MATCH EPT-2 FINISH MATCH EXISTING DFS-1 DIRECT-APPLY FINISH SYSTEM MANUFACTURER STO PRODUCT STOQUIK GOLD COLOR MATCH SHERWIN WILLIAMS SW 6995 SUPERWHITE FINISH STOLIT 1.0 A00.7 EXTERIOR ELEVATIONS LV SCALE NORTH BUILDING ELEVATION - WILLIAM HILTON PKWY (US HWY 278) 3/16" = 1'-0" 2 SCALE SOUTH BUILDING ELEVATION - LAFAYETTE PLACE 3/16" = 1'-0" 1 JPM Chase Retail Banking Center 2 Lafayette Place, Hilton Head Island, SC 29926 Hilton Head Design Review Board PRINTED 11/12/2025 SHEET NUMBER SHEET TITLE PROJECT INFORMATION BLOCK CHECKED BY: DRAWN BY: DATE: JOB #: 254009 11-12-2025 TN ISSUE/BY DATE DESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr. Suite 600 Tampa, FL 33602 P: 813-323-9233 FL Lic#AR-0014752 www.bdgllp.com Architect of Record: Christopher Kirschner, AIA, LEED AP SC License No. 5822 Page 78 of 86 B.O. SOFFIT +12'-9" T.O. WINDOW +8'-8" T.O. SLAB/FND. +0'-0" FINISH GRADE VARIES T.O. HIGH ROOF PEAK +35'-2" T.O. MED ROOF PEAK +31'- 3" B.O. DRIVE_UP CANOPY +11'-2" B.O. DRIVE_UP CANOPY +25'-8" GABLE ROOF PEAK +25'-2" GABLE ROOF EAVE +16'-9" NEW BUILT-UP GABLE ROOF NEW STOREFRONT NEW BUILT-UP GABLE ROOFNEW ROOF AT DRIVE-UP DRIVE-UP ATM AND AFTER HOURS DEPOSITORY TREX SECLUSIONS COMPOSITE FENCE 'WINCHESTER GREY' 7'-0" EPT-2TYP. AT ALL WINDOW TRIM EPT-2 EIFS-1 TR-1 RF-1 EPT-1 RF-1 EIFS-1 TR-1 EPT-2 EPT-1 B.O. SOFFIT +12'-9" T.O. WINDOW +8'-8" T.O. SLAB/FND. +0'-0" FINISH GRADE VARIES T.O. HIGH ROOF PEAK +35'-2" T.O. MED ROOF PEAK +31'- 3" GABLE ROOF PEAK +25'-2" GABLE ROOF EAVE +16'-9" ADDRESS TREX SECLUSIONS COMPOSITE FENCE 'WINCHESTER GREY' 7'-0" NEW STOREFRONT NEW BUILT-UP GABLE ROOF NEW BUILT-UP GABLE ROOF EIFS-1 TR-1 EIFS-1 EPT-2 RF-1 EPT-1 EPT-2TYP. AT ALL WINDOW TRIM EPT-1EPT-2 EPT-2 EPT-2 EIFS-1 EPT-2 EPT-1 RF-1 TR-1 RF-1 EXTERIOR FINISH MATERIALS THIS SCHEDULE IS COMPREHENSIVE. NOT ALL LISTED ITEMS ARE USED IN THIS PROJECT RF-1 ROOF FINISH MANUFACTURER CERTAINTEED PRODUCT LANDMARK- ASPHALT SHINGLES COLOR COBBLESTONE GRAY ST-1 STUCCO FINISH MANUFACTURER STO CORP. COLOR TO MATCH EPT-1 FINISH SAND FINISH TR-1 TRIM BOARD MANUFACTURER JAMES HARDIE PRODUCT 5/4 HARDIE TRIM BOARD (SMOOTH) COLOR PAINT TO MATCH EPT-2 SIZE 144" LENGTH X 7.25" WIDTH X 1" THICKNESS TR-2 SOFFIT BOARD MANUFACTURER JAMES HARDIE PRODUCT HARDIE VENTED SOFFIT PANELS COLOR PAINT TO MATCH EPT-2 SIZE 144" LENGTH X 16" WIDTH X 0.25" THICKNESS EPT-1 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7036 ACCESSIBLE BEIGE FINISH SEMI-GLOSS EPT-2 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7008 ALABASTER FINISH SEMI-GLOSS EPT-3 EXTERIOR PAINT MANUFACTURER BENJAMIN MOORE PRODUCT BM ULTRA SPEC EXT COLOR PAINT TO MATCH SW 7069 IRON ORE FINISH SEMI-GLOSS EIFS-1 EIFS PARAPET (DARK COLOR) MANUFACTURER STO CORP. (OR APPROVED EQUAL) PRODUCT STOTHERM PREMIER NEXT COLOR TO MATCH EPT-1 FINISH MATCH EXISTING EIFS-2 EIFS PARAPET (LIGHT COLOR) MANUFACTURER STO CORP. (OR APPROVED EQUAL) PRODUCT STOTHERM PREMIER NEXT COLOR TO MATCH EPT-2 FINISH MATCH EXISTING DFS-1 DIRECT-APPLY FINISH SYSTEM MANUFACTURER STO PRODUCT STOQUIK GOLD COLOR MATCH SHERWIN WILLIAMS SW 6995 SUPERWHITE FINISH STOLIT 1.0 A00.8 EXTERIOR ELEVATIONS LV SCALE EAST BUILDING ELEVATION - PARKING 3/16" = 1'-0" 2 SCALE WEST ELEVATION - DRIVE-UP 3/16" = 1'-0" 1 JPM Chase Retail Banking Center 2 Lafayette Place, Hilton Head Island, SC 29926 Hilton Head Design Review Board PRINTED 11/12/2025 SHEET NUMBER SHEET TITLE PROJECT INFORMATION BLOCK CHECKED BY: DRAWN BY: DATE: JOB #: 254009 11-12-2025 TN ISSUE/BY DATE DESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr. Suite 600 Tampa, FL 33602 P: 813-323-9233 FL Lic#AR-0014752 www.bdgllp.com Architect of Record: Christopher Kirschner, AIA, LEED AP SC License No. 5822 Page 79 of 86 WILLIAM HILTON PARKWAY (U.S. HIGHWAY 278) LAFAYETTE PLACE INDIGO RUN DRIVE LOT "E" "A SUBDIVISION PLAT OF INDIGO PARK PHASE II" PB 53 PG 144 LAND OF INDIGO RUN OWNER, LLC DB 3244 PG 1847 PIN: R510 008 000 0409 0000 2.503 ACRES OR 109,025 SF SPEED BUMP (TYP) SIGN-HANDICAP PARKING (TBR) HVAC UNIT (TYP) (TBR) ATM ENCLOSURE (TBR) OVERHANG (TBR) OVERHANG (TBR) CONCRETE (TBR) HANDICAP RAMP (TBR) C5 N88°39'07"W 129.67' C4 C3 C2 C1 N36°46'49"W 292.69' CONCRETESIDEWALK (TBR) CONCRETE SIDEWALK (TBR) CONCRETE SIDEWALK (TBR) 6' WOOD FENCE (TBR) CONCRETE SIDEWALK (TBR) 24.7'7.9' 24.7' 8.0' PILLAR (TYP) (TBR) PILLAR (TYP) (TBR) COVERED AREA (TBR) CURB AND GUTTER (TBR) CURB AND GUTTER (TBR) CURB AND GUTTER (TBR) CURB AND GUTTER (TBR) CURB AND GUTTER (TBR) CURB AND GUTTER (TBR) TPF TPF TPF TPFTPF TPF TPF TPF TPF TPF TPF PROP SAWCUT PROP SAWCUT PROP SAWCUT PROP SAWCUT PROP SAWCUT PROP SAWCUT PROP SAWCUT THIS PLAN TO BE UTILIZED FOR DEMOLITION PURPOSES ONLY 0 SCALE: 1" = 20' 2020 5 10 DEMOLITION ABBREVIATIONS ABBREVIATION DESCRIPTION (TBA)TO BE ABANDONED (TBR)TO BE REMOVED (TBV)TO BE VACATED (RELO)TO BE RELOCATED DISTURBED AREA SUMMARY FULL DEPTH PAVEMENT REMOVAL 1.5" MILL AND OVERLAY AREA TOTAL 27,682 SF (0.64AC) 14,978 SF (0.34AC) 42,660 SF (0.98AC) ORG. DATE - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY ########## 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com NCBELS P-1132 BOHLER ENGINEERING NC, PLLC THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER ENGINEERING NC, PLLC BOHLER Nov 07, 2025 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SOUTH CAROLINA CERTIFICATE O F A U THORIZATION BOHLER ENGINEERING NC PLLC NO. 4810 REENI GNE LANOISSEFORPDESNECIL No. 35866 R. ALLEN M CDOWELL SOUTH CAROLINA 11/07/25 FOR CONCEPT PURPOSES ONLY Nov 07, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NCA250028.00-0A----->LAYOUT: C-203 EXDM HM SHEET NUMBER: SHEET TITLE: Nov 07, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NCA250028.00-0A----->LAYOUT: C-203 EXDM HM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NCA250028.00-0A HM MJ 10/27/2025 P-CIVL-EXDM PROP. SITE PLAN DOCUMENTS PROPOSED CHASE BANK 2 LAFAYETTE PLACE HILTON HEAD ISLAND, SC 29926 PID: R510 008 000 0409 0000 C-203 EXISTING CONDITIONS AND DEMOLITION PLAN Page 80 of 86 WILLIAM HILTON PARKWAY (U.S. HIGHWAY 278) LAFAYETTE PLACE LOT "E" "A SUBDIVISION PLAT OF INDIGO PARK PHASE II" PB 53 PG 144 LAND OF INDIGO RUN OWNER, LLC DB 3244 PG 1847 PIN: R510 008 000 0409 0000 2.503 ACRES OR 109,025 SF C5 N88°39'07"W 129.67' C3 C2 C1 N36°46'49"W 292.69' 20' 20' 20' ~LANDSCAPED AREA~ ~LANDSCAPED AREA~ PROP 5' CURB TRANSITIONS BOLLARD ADA SIGN (TYP.) PROP CURB RAMP 4 PROP 18" CURB AND GUTTER (TYP) PROP 5' SIDEWALK (TYP) LIMIT OF PROP CURB AND GUTTER LIMIT OF PROP CURB AND GUTTER LIMIT OF PROP CURB AND GUTTER LIMIT OF PROP CURB AND GUTTER PROP MECHANICAL ENCLOSURE THIS PLAN TO BE UTILIZED FOR SITE LAYOUT PURPOSES ONLY 0 SCALE: 1" = 20' 2020 5 10 PAVING LEGEND REGULAR DUTY ASPHALT HEAVY DUTY CONCRETE 1.5" MILL AND OVERLAY (PER HILTON HEAD STANDARDS) CONCRETE SIDEWALK DISTURBED AREA SUMMARY FULL DEPTH PAVEMENT 1.5" MILL AND OVERLAY AREA TOTAL 27,682 SF (0.64AC) 9,725 SF (0.22AC) 37,407 SF (0.86AC) SEE SECTION DETAILS ON SHEET C-901 ORG. DATE - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY ########## 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com NCBELS P-1132 BOHLER ENGINEERING NC, PLLC THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER ENGINEERING NC, PLLC BOHLER Nov 07, 2025 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SOUTH CAROLINA CERTIFICATE O F A U THORIZATION BOHLER ENGINEERING NC PLLC NO. 4810 REENI GNE LANOISSEFORPDESNECIL No. 35866 R. ALLEN M CDOWELL SOUTH CAROLINA 11/07/25 FOR CONCEPT PURPOSES ONLY Nov 07, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NCA250028.00-0A----->LAYOUT: C-301 SITE HM SHEET NUMBER: SHEET TITLE: Nov 07, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NCA250028.00-0A----->LAYOUT: C-301 SITE HM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NCA250028.00-0A HM MJ 10/27/2025 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED CHASE BANK 2 LAFAYETTE PLACE HILTON HEAD ISLAND, SC 29926 PID: R510 008 000 0409 0000 ZONING TABLE ZONE: MAIN STREET (MS) USE: OTHER, COMMERCIAL SERVICES APPLICANT/ OWNER INFORMATION APPLICANT: JPMORGAN CHASE N.A. 1111 POLARIS PARKWAY, COLUMBUS, OH 43240 PROPERTY OWNER: INDIGO RUN OWNER LLC 41 ISLE OF VENICE DR, APT 302 FORT LAUDERDALE, FL 33301 BULK REQUIREMENTS ITEMREQUIREDPROPOSED MIN LOT AREAN/A2.503 (AC) MIN LOT WIDTHN/ATBD MIN YARD SETBACKS FRONT SETBACK20'20' SIDE YARD SETBACK20'20' REAR SETBACK50'50' MAX PERMITTED HEIGHT45'TBD MIN LANDSCAPE BUFFERS FRONTNONE- SIDENONE- REAR60' REAR BUFFER60' PARKING REQUIREMENTS MINIMUM REQUIRED STALLS1 SPACE PER 350 SF GFA (24 SPACES)51 ACCESSIBLE STALLS2 ADA SPACE FOR 26 TO 50 TOTAL SPACES2 C-301 SITE PLAN Page 81 of 86 WILLIAM HILTON PARKWAY (U.S. HIGHWAY 278) LAFAYETTE PLACE LOT "E" "A SUBDIVISION PLAT OF INDIGO PARK PHASE II" PB 53 PG 144 LAND OF INDIGO RUN OWNER, LLC DB 3244 PG 1847 PIN: R510 008 000 0409 0000 2.503 ACRES OR 109,025 SF TPF TPF TPF TPFTPF TPF TPF TPF TPF TPF TPF (62) JE (13) RU (9) RU (23) EP (11) HA (15) PB2 (19) PB2 (7) HW (11) HA (3) PVS (3) MW (3) PVS (3) SS (3) MW (3) SS (3) PVS(3) MW (8) HW (3) SS (3) MW (3) PVS (3) SS (3) MW (2) HV (16) EP SYMBOL CODEQTYBOTANICAL NAMECOMMON NAMESIZE CONTAINER TREES HV2 HAMAMELIS VIRGINIANACOMMON WITCH HAZEL1.5" CAL. MIN.CONTAINER/B&B SHRUBS HA23HYDRANGEA ARBORESCENS `ANNABELLE`ANNABELLE HYDRANGEA18-24" HT.CONTAINER HW 15HYDRANGEA QUERCIFOLIA 'PEE WEE'PEE WEE OAKLEAF HYDRANGEA12-18" HT. CONTAINER PB234PENNISETUM ALOPECUROIDES 'LITTLE BUNNY' LITTLE BUNNY FOUNTAIN GRASS1 GAL. CONTAINER GRASSES MW16MUHLENBERGIA CAPILLARIS 'WHITE CLOUD'WHITE CLOUD MUHLY GRASS 1 GAL. CONTAINER PVS12 PANICUM VIRGATUM 'SHENANDOAH' SHENANDOAH SWITCH GRASS1 GAL.CONTAINER SS 12SCHIZACHYRIUM SCOPARIUM 'THE BLUES'THE BLUES LITTLE BLUESTEM 1 GAL. CONTAINER SHRUB AREAS EP 39 ECHINACEA PURPUREACONEFLOWER1 GAL. CONTAINER JE 62 JUNCUS EFFUSUSSOFT RUSH1 GAL. CONTAINER RU22RUDBECKIA X 'AMERICAN GOLD RUSH'AMERICAN GOLD RUSH CONEFLOWER1 GAL. CONTAINER PLANT SCHEDULE WE S NAD83 NAD83 0 SCALE: 1" = 20' 2020 5 10L-101 LANDSCAPE PLAN THIS PLAN TO BE UTILIZED FOR LANDSCAPE PURPOSES ONLY GENERAL LANDSCAPE NOTES: 1. THESE LANDSCAPE PLANS ARE TO BE READ IN CONJUNCTION WITH THE LANDSCAPE SPECIFICATIONS, AND ASSOCIATED DETAILS FOUND ON THE LANDSCAPE DETAILS SHEET. THE GENERAL NOTES, FOUND ON THE NOTES PAGE OF THIS PLAN SET, ARE CONSIDERED PART OF LANDSCAPE PLANS. THE CONTRACTOR MUST REFER TO, AND FULLY COMPLY WITH, ALL NOTES, SPECIFICATIONS AND DETAILS DESCRIBED HEREIN, ON THE LANDSCAPE PLANS AND IN THE LANDSCAPE DETAILS SHEET. 2. ALL DISTURBED UNPAVED AREAS, EXCLUDING PLANTING BEDS, ARE TO BE INSTALLED AS LAWN IN ACCORDANCE WITH “MATERIALS” SECTION OF THE LANDSCAPE SPECIFICATIONS, UNLESS OTHERWISE SPECIFICALLY STATED ON THIS PLAN. 3. SHRUBS PLANTED ALONG HEAD-IN PARKING STALLS SHALL BE INSTALLED TO ALLOW A CLEARANCE OF TWO FEET FROM FACE OF CURB TO ALLOW FOR BUMPER OVERHANG. 4. PLANT MATERIAL SUBSTITUTIONS MUST BE FORMALLY SUBMITTED TO BOHLER AND THE MUNICIPALITY'S ENGINEERING AND LANDSCAPE CONSULTANTS FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 5. WITHOUT EXCEPTION, WEED BARRIER FABRIC SHALL NOT BE INSTALLED WITHIN ANY STORMWATER FACILITY, INCLUDING RAINGARDENS, INFILTRATION TRENCHES, VEGETATIVE SWALES AND STORMWATER BASINS. 6. IF IRRIGATION IS REQUIRED BY THE OWNER OR APPROVING MUNICIPALITY, THE CONTRACTOR SHALL PROVIDE AN IRRIGATION SYSTEM MEETING THE SPECIFICATIONS OF THE CHOSEN PRODUCT'S MANUFACTURER. THE IRRIGATION DESIGN SHALL ACCOMMODATE LAWN AND BED AREAS EACH UNDER SEPARATE ZONES TO MAXIMIZE WATER EFFICIENCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ANY PERMITS REQUIRED FOR THE INSTALLATION OF AN IRRIGATION SYSTEM. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL LANDSCAPING UNTIL PROJECT MAINTENANCE IS TURNED OVER TO THE PROPERTY OWNER OR OTHER RESPONSIBLE PARTY. SUCH RESPONSIBILITIES INCLUDE, BUT ARE NOT LIMITED TO, THE CARE, WATERING, AND MAINTENANCE OF ALL PLANT MATERIAL; LAWN MOWING; AND SEASONAL MAINTENANCE. ORG. DATE - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY ########## 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com NCBELS P-1132 BOHLER ENGINEERING NC, PLLC THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER ENGINEERING NC, PLLC BOHLER Nov 12, 2025 Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SOUTH CAROLINA CERTIFICATE O F A U THORIZATION BOHLER ENGINEERING NC PLLC NO. 4810 REENI GNE LANOISSEFORPDESNECIL No. 35866 R. ALLEN M CDOWELL SOUTH CAROLINA 11/07/25 FOR CONCEPT PURPOSES ONLY Nov 12, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NCA250028.00-0A----->LAYOUT: L-101 LSCP SH SHEET NUMBER: SHEET TITLE: Nov 12, 2025 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes no PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR H:\2025\NCA250028.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NCA250028.00-0A----->LAYOUT: L-101 LSCP SH THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NCA250028.00-0A HM MJ 10/27/2025 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED CHASE BANK 2 LAFAYETTE PLACE HILTON HEAD ISLAND, SC 29926 PID: R510 008 000 0409 0000 Page 82 of 86 Page 83 of 86 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 2 Lafayette Place – Chase Bank DRB-001104-2025 DATE: 11/25/2025 CATEGORY: Alteration RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Provide a materials board Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 84 of 86 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Provide a roof plan Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Provide any exterior lighting cut sheets you may be placing on or around the building. Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project There could be more landscaping at the front entrance of the building or around the building. Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Page 85 of 86 3 Landscape plan Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Alteration submittal for 2 Lafayette Place, Chase Bank with the following conditions: 1. Provide a materials board. 2. Provide a roof plan. 3. Provide any exterior lighting cut sheets you may be placing on or around the building. 4. There could be more landscaping at the front entrance of the building or around the building. 5. Any additional information as required by the Board. Page 86 of 86

Source: Town of Hilton Head Island website. First collected Oct 26, 2026.