RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Nov 12, 2025 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Wednesday, November 12, 2025, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Council Chambers The Design Review Board meeting will be held in person at Town Hall in Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of October 28, 2025 4. Unfinished Business a. DRB-001075-2025 - Sandlewood Food Pantry - 8 August Lane - Final 5. New Business 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Page 1 of 37 Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 37 Town of Hilton Head Island Design Review Board Meeting Minutes 10/28/2025 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Tuesday, October 28, 2025, 1:30 PM Minutes 1. Call to Order Chair Carstens called the meeting to order at 1:30pm. In attendance: Judd Carstens, Annette Lippert, Tom Parker, Todd Theodore, Megan Fitzpatrick, Patricia Pastor, Cathy Foss. 2. Adoption of the Agenda Melissa Paul-Leto, Principal Planner, proposed changes to the published agenda order. The change moved St. James Baptist Church to the second item in Unfinished Business, and moved Black Marlin Outdoor Bar to the first item in New Business. Mr. Parker made a motion to adopt the agenda with the changes. Ms. Pastor seconded, which passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of October 14, 2025 Ms. Fitzpatrick made a motion to approve the meeting minutes of October 14, 2025. Mr. Theodore seconded. The motion passed unanimously. 4. Unfinished Business a. DRB-001013-2025 - Patterson Family Park - Final Chair Carstens recused himself, passed the gavel to Vice Chair Lippert, and left the dias. Ms. Paul-Leto introduced the Patterson Family Park for Final review. The applicant answered questions from the Board. Mr. Parker motioned to approve with the following conditions: the roof color will change to be non-reflective; all conduit will be hidden to the greatest extent possible. Ms. Pastor seconded. Vice-Chair Lippert denied the motion which passed by a vote of 5 to 1. b. DRB-001018-2025 - Union Cemetery Road — St. James Baptist Church — Final Vice Chair Lippert passed the gavel to Chair Carstens who returned to the dias. Mr. Parker recused himself and left the dias. Ms. Paul-Leto presented the St. James Baptist Church for final review. The applicant answered questions from the Board. Vice Chair Lippert motioned to approve under the following conditions: confirmation of the school building as part of the scope and ramp details; drawings of the heights of the various Page 3 of 37 Town of Hilton Head Island Design Review Board Meeting Minutes 10/28/2025 Page | 2 building elements; the can light cut sheet will be submitted; the louver colors will match the building siding; the stained glass will be included in the resubmittal to staff; the brick crossings should not be painted but instead a contrasting brick; the gutters and downspouts will match the roof color. Ms. Pastor seconded. The motion passed unanimously. 5. New Business a. DRB-001002-2025 - 86 Helmsman Way - Black Marlin Outdoor Bar - Conceptual Mr. Parker recused himself and remained away from the dias. Ms. Paul-Leto presented the Black Marlin Outdoor Bar for conceptual review. The applicant answered questions from the Board. Vice Chair Lippert motioned to approve under the following conditions: study the roof extent as it relates to the Carolina Crab Company nearby so that those corners do not connect in plan but are more like the right side elevation; clarify how the pavement will be repaired to match existing; provide countertop materials, roof materials, tv's, fans, lights, colors of the garage doors, including the slats on the side; confirm that all the bar equipment is below the countertop height; provide heights for anything within the center portion of the structure like various equipment, heaters, etc. that get mounted. Ms. Foss seconded. The motion passed unanimously. b. DRB-000964-2025 - 124 Arrow Road - Monument Sign Mr. Parker returned to the dias while Mr. Theodore recused himself and left. Ms. Paul- Leto presented the Monument Sign for review. The applicant answered questions from the Board. The Board suggested that a hierarchy on the sign would make it look less like a directory, a stucco base should be added, the cap color should not be white, the sign's relative size and location to the building almost make the sign moot and lighting should be considered. Chair Carstens motioned for the applicant to implement input from the Board and resubmit the project to staff and the Chair and Vice Chair for review. Mr. Parker seconded. The motion was approved unanimously. 6. Public Comment - Non Agenda Items Mr. Theodore returned to the dias. Citizen Taiwan Scott spoke in reference to cultural expression through design colors and asked that the Board consider colors that reflect the Gullah Geechee community in addition to the Town color scheme as we introduce more parks to the area and update the LMO. 7. Board Business The Board discussed Beach Properties of Hilton Head and requested that staff review what was approved regarding the primer and roof color. An update on construction near Crazy Crab was requested. Staff proposed that 2026 meetings take place on Wednesdays which would require Board approval and an amendment to the Rules of Procedure. 8. Staff Reports 9. Adjournment Page 4 of 37 Town of Hilton Head Island Design Review Board Meeting Minutes 10/28/2025 Page | 3 The meeting adjourned at 3:38pm. Page 5 of 37 Page 6 of 37 Last Revised 01/21/15 1 Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: ___________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________________ Project Address: _____________________________________ Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Zoning District: _______________________________ Overlay District(s): ___________________________________ Town of Hilton Head Island Community Development Department One Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov CORRIDOR REVIEW, MAJOR DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS Digital Submissions may be accepted via e-mail by calling 843-341-4757. Project Category: _____ Concept Approval – Proposed Development _____ Alteration/Addition _____ Final Approval – Proposed Development _____ Sign FOR OFFICIAL USE ONLY Date Received: _____________ Accepted by: ______________ DRB #:___________________ Meeting Date: _____________ Submittal Requirements for All projects: _____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16- 2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island. Additional Submittal Requirements: Concept Approval – Proposed Development _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. Page 7 of 37 Last Revised 01/21/15 2 Note: All application items must be received by the deadline date in order to be reviewed by the DRB per LMO Appendix D: D-23. A representative for each agenda item is strongly encouraged to attend the meeting. Are there recorded private covenants and/or restrictions that are contrary to, conflict with, or prohibit the proposed request? If yes, a copy of the private covenants and/or restrictions must be submitted with this application. YES NO To the best of my knowledge, the information on this application and all additional docum entation is true, factual, and complete. I hereby agree to abide by all c onditions of any approvals granted by the Town of Hilton Head Island. I understand that such conditions shall a pply to the subject propert y only and are a right or obligation transferable by sale. I further understand that in the event of a State of Em ergency due to a Disaster, the review and approval times set forth in the Land Management Ordinance may be suspended. SIGNATURE DATE Additional Submittal Requirements: Final Approval – Proposed Development _____ A final written narrative describing how the project conforms with the conceptual approval and design review guidelines of Sec. 16-3-106.F.3. _____ Final site development plan meeting the requirements of Appendix D: D-6.F. _____ Final site lighting and landscaping plans meeting the requirements of Appendix D: D-6.H and D-6.I. _____ Final floor plans and elevation drawings (1/8"=1'-0" minimum scale) showing exterior building materials and colors with architectural sections and details to adequately describe the project. _____ A color board (11"x17" maximum) containing actual color samples of all exterior finishes, keyed to the elevations, and indicating the manufacturer's name and color designation. _____ Any additional information requested by the Design Review Board at the time of concept approval, such as scale model or color renderings, that the Board finds necessary in order to act on a final application. Additional Submittal Requirements: Alterations/Additions _____ All of the materials required for final approval of proposed development as listed above, plus the following additional materials. _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ Photographs of existing structure. Additional Submittal Requirements: Signs _____ Accurate color rendering of sign showing dimensions, type of lettering, materials and actual color samples. For freestanding signs: _____ Site plan (1”=30’ minimum scale) showing location of sign in relation to buildings, parking, existing signs, and property lines. _____ Proposed landscaping plan. For wall signs: _____ Photograph or drawing of the building depicting the proposed location of the sign. _____ Location, fixture type, and wattage of any proposed lighting. Page 8 of 37 Page 9 of 37 1 October 28, 2025 Town of Hilton Head Island DRB One Town Center Court Hilton Head Island, SC 29928 Project Narrative for Sandalwood Community Food Pantry The attached are the responses to DRB’s conditions of the approval for DRB-000981-2025 1. No shinny metal on the roof and consider adding color to the roof. We are using Pac Clad Musket Gray for the roof. See the color elevations and color board. 2. Consider a crosswalk for the parking lot. A crosswalk has been added that stretches from the adjacent pervious parking area and ties into the sidewalk next to the proposed building. Adequate pedestrian access should be available from all parking areas. See sheet C3.01 for crosswalk locations. 3. Add two additional foundation plantings to the N.E. side of the building. More foundation plantings have been added alongside the North East section of the building. This should help screen the entryway and provide an aesthetic view. See sheet L.2 for planting locations. 4. Provide a material and color board in person. We are including a material and color board. 5. Provide lighting specs, temperature, and color for the exterior lights to the market. We are providing spec sheets for the exterior lights. The color temperature will be 3000k. 6. Provide lighting specs for the parking lot. We are providing a lighting spec for the parking lot. 7. Provide elevations colored with measurements and material / color notated. We are providing color elevations with this submission. 8. Provide a roof plan for the market. We are providing a roof plan for both the market and pavilion. 9. Provide a photometric plan. We are providing a photometric plan for the site. Thank you for your time and consideration of this project. Timothy C Probst, AIA Page 10 of 37 Page 11 of 37 A R CH ITECT S A R CH ITECT S parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 80'-0" 40'-0"7'-0" 6'-0" 14'-0" 14'-0" 14'-0" 14'-0" 14'-0" 4'-0" 11'-0" 23'-6" 10'-6" 6'-0" 5'-0" 8'-1"1'-8" 5'-3 1/2" 8'-5" 3'-6" 1'-0" 38'-0" 1'-0" 3'-0" 7'-0" 17'-0" 6" 18'-0" 18'-7" 17'-8" 25'-9" 12'-9" 2'-6" 6'-6" 9'-3" 9'-3" 9'-3" 9'-3" FOOD PANTRY OPEN FLOOR 54'-8 X 39' STORAGE DELIVERY 25'-0" X 23'-0" PUBLIC RESTROOM CONF.ROOM 18'-0" X 20'-0" CATERING KITCHEN WARMING OVEN(3) BIN SINK WORK SPACE HAND SINK WORK TABLES WORK TABLES WORK TABLES STORAGE SHELVES STORAGE SHELVES STORAGE SHELVES STORAGE SHELVES STORAGE SHELVES STORAGE SHELVES STORAGE SHELVES ENTRY EXIT STORAGE SHELVES W/ HIGH GLASS ABOVE STORAGE SHELVES W/ HIGH GLASS ABOVE D.F. RAISED PLANTER EXPOSED CEILING WITH WOOD TRUSSES COOLER FREEZER OFFICE 10'-0" X 10'-6" STOR. PRIVATE BATH 2 A.2.1 2 A.2.1 BUILDING SECTION 3 A.2.1 BUILDING SECTION 3 A.2.1 GENERATOR COMP. 48" FRIDGE 2 A.3.1 1 A.3.1 1 2 4 3 6 5 8 9 10 7 A A A A A A A A A B A A A 48" REF. ELECT. PANEL 3 A.1.2 34" HIGH COUNTER 42" HIGH COUNTER 2 A.3.2 1 A.3.2 6'-0" 8'-0" 2'-8" 8'-0" 2'-8" 7'-0" 7'-0" 7'-0" 3'-0" 2'-6"6'-0" 8'-0" 2'-8" 6'-0"3'-0" 3'-0" 3'-8"7'-0" 3'-8" 7'-0" 6'-0" 1 2 3 FRAMEDOOR Mat.Material / Finish Type REMARKSSize MARK FIRE RATING TW H Jamb depth DOOR & FRAME SCHEDULE 1 NOTE: 1. PROVIDE TEMPERED GLASS NOTED IN ELEV. KEYS. 2. SEE STRUCTURAL FOR DP RATINGS OF EXTERIOR DOORS. 4 5 NA NA 6 7 8 HARD- WARE MARK 9 10 FIRST FLOOR NA 2 NA NA 8'-0" 2 1/4" NA DOOR & FRAME ELEVATION KEYS HARDWARE SCHEDULE MARK REMARKSMFG. TYPE 2 1 ENTRANCE LOCK SCHLAGE 3 MFG. NUMBER AL 50 PD BATHROOM LOCK SCHLAGE AL 40 PD NOTES: 1. SUBMIT FULL HARDWARE SCHEDULE FOR REVIEW 2. ALL FINISHES TO BE 626 3'-0" 7'-0" 1 3/4" WOOD 2'-6" NA NA WOOD TYPE "1" TYPE "2" TYPE "3" WOOD 7'-0" 1 3/4" WINDOW ELEVATION KEYS MARK "A" 1 1 1 1 1 6'-0" 8'-0" 1 3/4"3'-0" 1 3/4"3'-0" 7'-0" 1 3/4"3'-0" 7'-0" 1 3/4"3'-0" 2 3 5 3 6 WOOD WOOD WOOD WOOD WOOD WOOD PASSAGE LOCK SCHLAGE AL 10 PD A TYPE MFG. NUMBER SIZE REMARKSMARK WINDOW SCHEDULE STOREFRONT 3'-0" X 3'-8" NA2'-6" 7'-0" 1 3/4" 36WOOD NA7'-0" 1 3/4"6'-0" 4WOOD 2 3 1 MARK "B" 6'-0" X 7'-0"B STOREFRONT TYPE "4" TYPE "5" TYPE "6" 8'-0" WOOD WOOD WOOD WOOD WOOD WOOD WOOD WOOD WOOD 18'-0" 2 1/4" 16'-0" TEMP. GLASS TEMP. GLASS TEMP. GLASS 1 A.1.1SCALE: 1/4"=1'-0" FIRST FLOOR PLAN A.1.1 Page 12 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD FOOD PANTRY OPEN FLOOR EXPOSED CEILING WITH WOOD TRUSSES COOLER FREEZER CONF.ROOM 12'-0" HIGH SHEETROCK CEILING 12'-0" HIGH SHEETROCK CEILING 12'-0" HIGH SHEETROCK CEILING 12'-0" HIGH SHEETROCK CEILING 6 12 6 12 3 12 RIDGE 5'-0" TRANSFER AREA 5'-0" 2'-0" 3'-6" 1'-0" 3'-0" 6" 7'-6" 8'-0" PUBLIC RESTROOM F.D. ADULT H.C. TOILET T.P.H. GRAB BARS 4 A.1.2 D.F. W/ BOTTLE FILLER 5 A.1.2 6 A.1.2 FLOOR TO CEILING TILE ON THIS WALL ONLY TILE ON THESE WALLS-SEE ELEV. 1'-10" 3'-0" 6"3'-0" 1'-5" 1'-6"3'-4" 1'-3"1'-0" 7" 4" 3'-10" 2'-10" PROVIDE SOLID BLOCKING IN WALL FOR GRAB BARS, TYP. STAINLESS STEEL GRAB BARS MIRROR SOLID SURFACE TOP W/ UNDER MOUNT SINK AS PER PLUMBING DRW. REMOVABLE PLASTIC LAM SCREENS SLOPED BACK TO WALL BLOCK WALL AT SINK & BRACING POINTS TRIANGULAR BRACE SHEETROCK W/ EPOXY PAINT 3'-2" 2'-9" D.F. WITH BOTTLE FILLER TILE AS PER OWNER 1'-5" 3'-4" 1'-6" 3'-0" 5'-0" PROVIDE SOLID BLOCKING IN WALLS AT GRAB BARS STAINLESS STEEL GRAB BARS WALL TILE AS PER OWNER WITH BULLNOSE TOP SHEETROCK W/ EPOXY PAINT 1 A.1.2SCALE: 1/4"=1'-0" REFLECTED CEILING PLAN 2 A.1.2SCALE: 1/8"=1'-0" ROOF PLAN A.1.23 A.1.2SCALE: 1/2"=1'-0" RESTROOM PLAN 4 A.1.2SCALE: 1/2"=1'-0" RESTROOM ELEVATION 5 A.1.2SCALE: 1/2"=1'-0" RESTROOM ELEVATION 6 A.1.2SCALE: 1/2"=1'-0" D.F. ELEVATION Page 13 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 12'-0" 23'-0" 10'-8" TABBY SHELL BASE AND RAISED PLANTER VERTICAL WOOD SIDING BARN DOORS ON HARDWARE HIGH WINDOWS OVER SUPPLY SHELVES T.O.S. 12.5' MSL VEGGIE STAND VEGGIE STAND TABBY SHELL SONO TUBE BASE HEAVY TIMBER COLUMNS ON KNIFE PLATES STANDING SEAMED METAL ROOFING T.O.S. 12.5' MSL T.O.S. 12.5' MSL A.2.1 2 SCALE: 1/4"=1'-0" ENTRY DRIVE ELEVATION 1 SCALE: 1/4"=1'-0" ENTRY ELEVATION 3 A.2.1SCALE: 1/4"=1'-0" REAR ELEVATION A.2.1 A.2.1 Page 14 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD T.O.S. 12.5' MSL12'-0" 23'-0" WOOD TRUSSES AS PER STRUCTURAL BUILT IN STORAGE AS PER OWNER T.O.S. 12.5' MSL WOOD TRUSSES AS PER STRUCTURAL ACCENT TILE WALL AS PER OWNER WOOD FRONT AS PER OWNER T.O.S. 12.5' MSL 2 SCALE: 1/4"=1'-0" BUILDING SECTION 1 SCALE: 1/4"=1'-0" RIGHT SIDE ELEVATION 3 A.2.2SCALE: 1/4"=1'-0" BUILDING SECTION A.2.2 A.2.2 A.2.2 Page 15 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD TABBY SHELL STUCCO BASE HEAVY TIMBER COLUMNS- STAINED TO MATCH SIDING STAINED CYPRESS SIDING SEA GULL GRAY BAY LIGHTS- DARK BRONZE SIERRA PACIFIC WINDOWS AND DOOR FRAMES BRONZE 024 BARN DOORS TO MATCH HEMLOCK GREEN 024 TABBY SHELL STUCCO BASE HEAVY TIMBER COLUMNS- STAINED TO MATCH SIDING STANDING SEAMED METAL ROOFING- PAC CLAD MUSKET GRAY STAINED CYPRESS SIDING SEA GULL GRAY BAY LIGHTS- DARK BRONZE SIERRA PACIFIC WINDOWS AND DOOR FRAMES BRONZE 024 SIERRA PACIFIC DOORS HEMLOCK GREEN 024 2 SCALE: 1/4"=1'-0" ENTRY DRIVE ELEVATION 1 SCALE: 1/4"=1'-0" ENTRY ELEVATION A.2.3 A.2.3 BUILDING COLORS POSTS AND TABBY BASE PAC CLAD MUSKET GRAY SEA GULL GRAY BAY HEMLOCK GREEN 048 BRONZE 024 A.2.3 Page 16 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 2'-6" 12'-0" 2'-0" TOP OF SLAB @ 12'-6" MSL 4" 3000 PSI CONC. SLAB W/ 6X6 10/10W.W.F.- FLOAT FINISH 10 MILL VAPOR BARRIER TR. 2X6 MUD SILL 3000 PSI CONC. SEE STRUCTURAL COMPACTED & TREATED SOIL FOOTER STEEL SEE STRUCTURAL PARGE EXPOSED SLAB ROYAL WINDOW AND DOOR SYSTEMS 7640 SILL NOSE 2x6'S @ 16" O.C. WITH 1/2" PLYWD. SHEATHING TR. 1/2" PLYWD. SHEATHING FIRST 4'-0" 5/8" SHEETROCK OPEN CELL SPRAY FOAM INSULALTION 7/8" CEMENT STUCCO TO MATCH EXISTING ON MTL. LATH ON #15 FELT PAPER ON TYVEK DRAINAGE WRAP EXPOSED ALUM. FLASHING 12 6 CORRIGATED METAL ROOF PANELS ON ICE AND WATER SHIELD ON 5/8" PLYWOOD METAL DRIP 1X4 ON 1X6 TRIM SOFFIT BOARD WITH 1X2 BATTENS AT WALL AND PERPENDICULAR @ 8'-0" O.C. 2X6 PURLINS @ 2'-0" O.C. BUILT IN AS PER OWNER OPEN CELL SPRAY FOAM INSULATION FOR R20 VALUE SCISSOR TRUSS AS PER STRUCTURAL 1x8 CYPRESS NICKLE GAP ON TYVEK DRAINAGE WRAP 12'-0" 1'-6" 12'-0" 2'-0" ROYAL WINDOW AND DOOR SYSTEMS 7640 SILL NOSE 2x6'S @ 16" O.C. WITH 1/2" PLYWD. SHEATHING TR. 1/2" PLYWD. SHEATHING FIRST 4'-0" 5/8" SHEETROCK OPEN CELL SPRAY FOAM INSULALTION 7/8" CEMENT STUCCO TO MATCH EXISTING ON MTL. LATH ON #15 FELT PAPER ON TYVEK DRAINAGE WRAP EXPOSED ALUM. FLASHING 1x8 CYPRESS NICKLE GAP ON TYVEK DRAINAGE WRAP TR. 4X12 BEAM SIMPSON STRUCTURAL SCREWS- SEE STRUCTURAL THRU BOLTS AS PER STRUCTURAL 12 3 DBL. TR. 2X8 RAFTERS @ 2'-0" O.C. METAL DRIP THRU BOLTS IN KNIFE PLATE AS PER STRUCTURAL TR. 8X8 POSTS 1'-8" ROUND CONCRETE BASE WITH TABBY STUCCO FINIAH ROOF OVERHANG BEYOND TOP OF SLAB @ 12'-6" MSL SLOPE 1/8" PER 1'-0" TR. 2X4 PURLINS @ EXPOSED PORCH CEILINGS CORRIGATED METAL ROOF PANELS ON ICE AND WATER SHIELD ON 5/8" PLYWOOD METAL DRIP UNDER ICE AND WATER SHEILD 1 A.3.1SCALE: 1"=1'-0" WALL SECTION2 A.3.1SCALE: 1"=1'-0" WALL SECTION A.3.1 Page 17 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 1'-4" 2' T.O.S. 12.5' MSL 10 MILL VAPOR BARRIER 3000 PSI CONC. SEE STRUCTURAL COMPACTED & TREATED SOIL FOOTER STEEL SEE STRUCTURAL FOOTER STEEL SEE STRUCTURAL ROYAL WINDOW AND DOOR SYSTEMS 7640 SILL NOSE 2x6'S @ 16" O.C. WITH 1/2" PLYWD. SHEATHING TR. 1/2" PLYWD. SHEATHING FIRST 4'-0" 5/8" SHEETROCK OPEN CELL SPRAY FOAM INSULALTION EXPOSED ALUM. FLASHING 1x8 CYPRESS NICKLE GAP ON TYVEK DRAINAGE WRAP 8" SOLID FILLED CMU BLOCK WALL WITH STUCCO FINISH TO MATCH THE BUILDING LIQUID APPLIED WATER- PROOFING INSIDE PLANTER TR. 6 x 6 POSTS SET IN CONC. FOOTERS 1X6 BOARDS FRONT AND BACK WITH 3" SPACE BETWEEN THEM TR. 2X8 CAP W/ CUT DRIP- SLOPE SLIGHTLY SLOPED BROOM FINISH CONC. @ 1/4"/1'-0" (3) TR. 2 x 4's 1 x 4 TRIM 2 A.3.2SCALE: 1"=1'-0" WALL SECTION A.3.2 1 A.3.2SCALE: 1"=1'-0" SERVICE YARD DETAIL Page 18 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 1 1/2" 1 1/2" PAN FLASHING IN SEALANT HEAD SILL SILL BELOW 5/4 X 4 CEMENT BOARD TRIM CONCEALED FLASHING CONCEALED FLASHING CONCEALED FLASHING JAMB 5/4x6 CEMENT BOARDTRIM TYP. SIDING EXPOSED CAP FLASHING 1 1/2"X 2 1/2" DRIP CAP ROYAL WINDOW AND DOOR SYSTEMS 7640 SILL NOSE 6" 3" CUT BUILDING WRAP FOLD IN AND STAPLE CUT WIDTH OF FLASHING & CREATE TOP FLAP FROM HOUSE WRAP 45 FOLD FLAP UP AND TAPE APPLY SILL FLASHING STAPLE, NAIL, OR TAPE CORNERS TEMPORARILY FASTEN TOP CORNER SEAL ALL FLANGE OVERLAPS. LAP TOP SIDE FLANGES OVER BOTTOM SIDE FLANGES TO THE EXT. SHIM SIDES & LEVEL WINDOW. FASTEN ON ALL SIDES BY SCREW OR NAIL APPLY FLASHING AT SIDES, OVERLAPPING SILL FLASHING APPLY SEALANT AT TOP ONLY. QUICKLY GO TO NEXT STEP PLACE METAL HEAD FLASHING IN SEALANT, CENTERING OVER UNIT. APPLY FLASHING OVER HEAD FLASHING LEG, OVERLAPPING SIDE FLASHING FOLD HOUSE WRAP DOWN AND TAPE INSTALL JAMSILL GUARD SILL PAN OR EQ. SET AND LEVEL SHIMS AT ALL SIDE JAMB LOCATIONS 3/8" SEALANT BEAD CENTER WINDOW IN OPENING ON SHIMS INSERT BACKER ROD ON (2) SIDES AND SILL INSERT BACKER ROD ON (2) SIDES, SILL, AND HEAD APPLY SEALANT ON (2) SIDES AND SILL APPLY SEALANT ON (2) SIDES, SILL, AND HEAD LEAVE GAP BETWEEN EXT. STUCCO WINDOW FOR SEALING WINDOW INSTALLATION DIAGRAM N.T.S. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 INTERIOR VIEW INTERIOR VIEW 1 A.4.1SCALE: 1 1/2"=1'-0" WINDOW DETAIL A.4.1 Page 19 of 37 Page 20 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authorization from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 10'-0" 17'-3" TABBY SHELL SONO TUBE BASE HEAVY TIMBER COLUMNS ON KNIFE PLATES SCISSOR TRUSS 18'-4" 12'-0" 12'-0" 10'-0" 17'-3" TABBY SHELL SONO TUBE BASE HEAVY TIMBER COLUMNS ON KNIFE PLATES SCISSOR TRUSS A.1.1 1 SCALE: 1/4"=1'-0" PAVILION PLAN 4 SCALE: 1/4"=1'-0" ENTRY ELEVATION 6 SCALE: 1/4"=1'-0" RIGHT SIDE ELEVATION A.1.1 A.1.1 A.1.1 2 SCALE: 1/4"=1'-0" PAVILION ROOF PLAN A.1.1 3 SCALE: 1/4"=1'-0" REAR ELEVATION 5 SCALE: 1/4"=1'-0" SIDE ELEVATION A.1.1 A.1.1 Page 21 of 37 ARCHITECTS ARCHITECTS parkerdesigngrouparchitects 843 785 5171 POST OFFICE BOX 5010 HILTON HEAD ISLAND SC 29938 REVISIONS DATE DATE OF ISSUE: TP SHEET OF SHEETS TP SCALE DRAWN BY CHECKED BY JOB NO. 10/28/25 These documents & designs are the property of Parker Design Group|Architects & are not to be used or reproduced there of or for designs, working drawings, or construction of buildings without the written authori zation from the copyright owner PDG|Architects 2025 copyright C A NEW FOOD PANTRY FOR: Hilton Head Island, SC SANDALWOOD 10'-0" 1'-6" 3'-0" SCISSOR TRUSS AS PER STRUCTURAL THRU BOLTS IN KNIFE PLATE AS PER STRUCTURAL TR. 8X8 POSTS 1'-8" ROUND CONCRETE BASE WITH TABBY STUCCO FINIAH TOP OF SLAB @ 12'-6" MSL SLOPE 1/8" PER 1'-0" TR. 4X12 BEAM THRU BOLTS AS PER STRUCTURAL CORRIGATED METAL ROOF PANELS ON 2X4 PURLINS @ 2'-0" O.C. 12 6 ANGLE BRACKETS AS PER STRUCTURAL 4 SCALE: 1"=1'-0" PAVILION SECTION A.3.1 A.3.1 Page 22 of 37 Page 23 of 37 30' BLDG STBCK30' BLDG STBCK30' BLDG STBCK 20' BLDG STBCK 25' TYPE C BUFFER25' TYPE C BUFFER 15' REDUCED TYPE C BUFFER 25' TYPE C BUFFER30' BLDG STBCK 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 25' TYPE C BUFFER TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE 1659 SF WETLAND (0.038 AC.) 10 8 9 11 11 12 1213131414 109 11 1112 10 111213 16171718181512 13 14 10 11 109 W TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP SFSFSFSFSFSFSFLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD SFSFSFSFSFSFSFSFSFSFSFSF SFSF SFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF TP TPTP TPTPTP TPTP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TPTPTPTPTPTPTP TPTP PB PBPBPBPBPB TP 25' TYPE C BUFFER 15' MAINTENANCE ESMT 15' MAINTENANCE ESMT REMOVE 457 LF OFEXISTING 5' CHAINLINK FENCE REMOVE 1906 SQFT OF EXISTINGPAVEMENT EXISTING 6" PVCWATERLINEPER SUEEXISTING 16" PVCWATERLINE PER SUE EXISTING 24" PVC WATERLINEPER HHPSD UTILITY MAPEXISTING 12" PVCPER HHPSDUTILITY MAP EXISTING 14" PVCRECLAIMED WATERLINEPER SUEEXISTING WATERSTRUCTUREPER SUEEXISTING FORCEMAINPER SUE EXISTING AIRRELEASE VALVEPER SUEEXISTING WATERMANHOLE PER SUE EXISTING 10" SEWER LINEPER SUE REMOVE 38 LF OFEXISTING 15" RCPEXISITING DIRT ROADTO BE ABANDONED EXISTINGHYDRANT REMOVE 29 LF OFEXISTING 18" RCPREMOVE EXISTINGINLET STRUCTURE EXISITING DIRT ROADTO BE ABANDONED REMOVE 457 LF OFEXISTING 5' CHAINLINK FENCE REMOVE 457 LF OFEXISTING 5' CHAINLINK FENCE EXISTING 5' CHAINLINK FENCE TOREMAINEXISTING 8' BARBED CHAINLINK FENCE TO REMAINBREAKER PANEL TO REMAINTELEPHONEBOX TO REMAIN 2423 SF OF EXISTINGPAVEMENT TO REMAIN EXISTING FENCETO REMAIN CONTRACTOR TO VERIFY EXISTINGSTORM INFRASTRUCTUREEXISTING TRAILSAWCUT CLEAN EDGE NO CONSTRUCTION ACTIVITY IS PERMITTEDAT ANY TIME WITHIN THE POTENTIALWETLAND AND/OR 20' WETLAND BUFFER!! EX. CONDITONS & DEMO PLAN C1.01SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25LEGEND:SILT FENCE, SEE DETAILLODLIMITS OF DISTURBANCESFEXISTING PAVEMENTPROPERTY BOUNDARY STORM INLET PROTECTION, SEE DETAILPERMANENT SEEDING AREA STORM INLET STRUCTURESSDSTORM DRAIN PIPE PERMANENT SEEDINGPSSILT SACK INLET PROTECTION, SEE DETAILCLEARING AND GRUBBING AREACGCLEARING AND GRUBBING AREA 1. OWNER'S REPRESENTATIVE, GOVERNING AGENCIES AND UTILITY COMPANIESSHALL BE NOTIFIED 72 HOURS PRIOR TO ANY DEMOLITION OPERATIONS.2. CONTRACTOR SHALL COORDINATE WITH GOVERNING AGENCIES AND ALLUTILITY COMPANIES TO COORDINATE TIMING OF AND RESPONSIBILITY OFDEMOLITION OPERATIONS INCLUDING ANY REQUIRED INSPECTIONS.3. CONTRACTOR SHALL REMOVE ALL BUILDINGS, FOUNDATIONS, PAVEMENT,CURB, SIGNS, LIGHTS, FENCES, TREES, SHRUBS, UTILITIES AND ANY OTHERSTRUCTURES AS INDICATED AND DISPOSE OF THAT MATERIAL IN A LEGALMANNER.4. UTILITIES TO REMAIN IN-PLACE SHALL BE PROTECTED BY THE THE CONTRACTORFROM DAMAGE IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES.5. DEMOLITION OF ASPHALT PAVING SHALL INCLUDE REMOVAL OF SURFACE ANDANY BINDER SECTIONS. AFTER ASPHALT REMOVAL, THE SITE GEOTECHNICALENGINEER SHALL INSPECT STONE BASE COURSE TO DETERMINE CONDITION. IFEXISTING STONE BASE COURSE IS ACCEPTABLE TO PROJECT GEOTECHNICALENGINEER, IT SHALL BE REUSED. UNACCEPTABLE STONE BASE COURSE SHALLBE DISPOSED OF OFF-SITE IN A LEGAL MANNER.6. ALL EXISTING PAVEMENT EDGES SHALL BE SAW CUT TO A STRAIGHT EDGE. ALLNEW PAVEMENT EDGES SHALL BE CONSTRUCTED IN A STRAIGHT AND NEATMANNER.7. ANY HISTORICALLY SIGNIFICANT ARTICLES (CORNER STONES, ETC.) FOUNDDURING CONSTRUCTION SHALL BE PRESENTED TO THE OWNER FORCLASSIFICATION. CONTRACTOR SHALL STOP WORK IN THE AREA OF THE FINDAND IMMEDIATELY NOTIFY THE OWNER AND GOVERNING AGENCIES FORDIRECTION. THE OWNER SHALL RETAIN ALL MATERIAL IT CONSIDERSSIGNIFICANT. ALL OTHER MATERIAL SHALL BE DISPOSED OF OFF-SITE.8. THE CONTRACTOR SHALL TURN OVER ANY REMOVED PUBLIC UTILITY ITEMS, i.e.WATER METERS, TO THE UTILITY DEPARTMENT. ALL OTHER MATERIAL SHALL BEDISPOSED OF OFF-SITE IN A LEGAL MANNER.9. ALL DEBRIS FROM DEMOLITION OPERATIONS SHALL BE DISPOSED OF OFF-SITEIN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS.10. TREES TO BE SAVED SHALL BE PROTECTED FROM CONSTRUCTIONDISTURBANCE PER DETAIL. TREES NOT SHOWN TO BE SAVED SHALL BEREMOVED. 11. THE CONTRACTOR IS REQUIRED TO MEET ALL APPLICABLE LOCAL, STATE, OSHAAND FEDERAL REGULATIONS CONCERNING PROJECT SAFETY AND ASSUMESFULL RESPONSIBILITY FOR SAFETY ON THE PROJECT.12. CONTRACTOR IS TO VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO ANDDURING CONSTRUCTION AND REPORT ANY CONFLICTS OR DISCREPANCIES TOTHE ENGINEER.13. CONTRACTOR SHALL INSTALL TEMPORARY CONSTRUCTION FENCING ASNECESSARY AND AT THE DIRECTION OF THE OWNER OR GOVERNING AGENCIESFOR PUBLIC SAFETY AND JOB SITE SECURITY.14. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING UTILITIES PRIOR TO ANY SITECONSTRUCTION OR DEMOLITION. THIS SHALL INCLUDE, BUT SHALL NOT BELIMITED TO, BOTH MAIN AND SERVICE LINES FOR THE FOLLOWING:· POTABLE WATER LINES· SANITARY SEWER LINES· ELECTRIC LINES (OVERHEAD AND UNDERGROUND)· GAS LINES· TELEPHONE LINES· CABLE TELEVISION LINES· STORMWATER CONVEYANCE LINES15. ANY SUBCONTRACTOR BIDDING ON THIS JOB SHALL BE REQUIRED TO PERFORMA SITE VISIT PRIOR TO SUBMITTAL OF BID.16. UNLESS SPECIFICALLY NOTED ON THE PLAN TO BE ABANDONED IN PLACE ORPROTECTED, ALL UTILITIES ON SITE (OVERHEAD OR UNDERGROUND) SHALL BEENTIRELY REMOVED TO THE PROPERTY LINE, OR SERVICE POLE. ENDS OF PIPESBEYOND PROPERTY LINE TO BE ABANDONED SHALL BE PROPERLY CAPPED ORPLUGGED AS REQUIRED BY GOVERNING UTILITY COMPANY.17. DEMOLITION OF BUILDINGS SHALL INCLUDE ALL PORTIONS OF THE STRUCTURE,BOTH ABOVE GROUND AND SUBSURFACE.18. CONTRACTOR IS RESPONSIBLE FOR PROVIDED ANY TRAFFIC CONTROLMEASURES NECESSARY FOR DEMOLITION OPERATIONS.19. DEMOLITION OF CONCRETE CURB, CURB AND GUTTER, AND SIDEWALK SHALL BECONSIDERED TO EXTEND TO THE NEXT CONSTRUCTION JOINT PAST THE LIMITSSHOWN ON THE DEMOLITION PLAN. DEMOLITION NOTES: TPSTRUCTURE TO BE DEMOLISHEDTREE PROTECTION FENCE NORTH 1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" TREE LEGEND:SPECIMEN SIGNIFICANTSIGNIFICANT TO BE REMOVEDSPECIMEN TO BE REMOVED NON-SIGNIFICANT / SPECIMENTO BE REMOVEDNON-SIGNIFICANT / SPECIMEN GATE VALVE TREE PROTECTION NOTES:1. WHERE COMPACTION MIGHT OCCUR DUE TOCONSTRUCTION TRAFFIC OR MATERIALS DELIVERY THROUGH ATREE AND BUFFER PROTECTION ZONE, THE AREA MUST FIRSTBE MULCHED WITH A MINIMUM FOUR-INCH LAYER OF WOODCHIPS. EQUIPMENT OR MATERIALS STORAGE SHALL NOT BEALLOWED WITHIN A TREE AND BUFFER PROTECTION ZONE. LIMITS OF DISTURBANCE:1.16 AC.NOTE: PROTECT ALL EXISTING TREES EXCEPTAS NOTED Page 24 of 37 LOADING ZONE OPEN AIRPAVILION513-SF VAN XXXXXXXXXXX LS FOOD PANTRY80' x 40'3,200 SFFFE: 12.5' COVERED ENTRYWAY RAISED PLANTER (REFER TO ARCH.) XXXSERVICE YARD (REFER TO ARCH.) 30' BLDG STBCK30' BLDG STBCK30' BLDG STBCK 20' BLDG STBCK 25' TYPE C BUFFER25' TYPE C BUFFER 15' REDUCED TYPE C BUFFER 25' TYPE C BUFFER30' BLDG STBCK 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 25' TYPE C BUFFER TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE PONDTOB: 9.75BOP: 7.502-YR EL: 8.1910-YR EL: 8.8525-YR EL: 9.17100-YR EL: 9.57TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD TP TPTP TPTPTP TPTP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TPTPTPTPTPTPTP TPTP PB PBPBPBPBPB TP 25' TYPE C BUFFER 25'R 25'R 3'R 45'R 25'R 25'R 25'R 50'R 25'R 25'R 50'R 18'R 23'R 57'R 52'R 25'R 40'R 5'R 3'R 1'R 15'R 10 SP @ 9'=90' 3 SP @ 9' = 29'24' 15' 15' 12' 5'5'25' 59.8' 2' 13.83' 31.47'20.22' 8' 20'25.67'5' 5' 1' CONCRETE BORDERAROUND INFILTRATION TRENCH18' 7'17' 10'10'16' 25' 30' 5'PROP. FIRE LANE STRIPING(SEE DETAIL C3.02)PROP. GATEDENTRANCE YELLOW THERMOPLASTICCROSSWALK & STOP BAR(SEE DETAIL C3.02) YELLOW THERMOPLASTIC ARROW WHEEL STOPS - TYP.(SEE DETAIL C3.02) WHEEL STOPS - TYP. (SEE DETAILC3.02) LIFT STATION SEESHEET C6.02 ADA ACCESSIBLEROUTE DO NOT ENTERSIGN ONE WAY SIGNONE-WAY SIGN BEGIN NEW PVMT AT SAW CUTLIMITS SHOWN ON SHEETC1.01 END GRAVEL WALKWAYAT PROPERTY ROW LIMITSEXISTING PAVEMENT 1,440 SF GRAVEL PARKING LOT& INFILTRATION TRENCH PED. WARNING SIGN HANDICAP SIGNAWNING LIMITS YELLOW THERMOPLASTIC ARROWDETECTABLEWARNINGPAVERS NO PARKING LOADING ZONESIGNBOLLARDS TAPER FROMEX. PVMT TO25' EOP-EOP BIKE RACK 120 SF SERVICE YARD TRAFFIC LAWS ENFORCEDBY LOCAL AUTHRORITIESSIGN DETECTABLEWARNINGPAVERS DOUBLE YELLOWCENTERLINE ALONGTWO-WAY DRIVE WAY SOLID WHITE CENTERLINEALONG ONE-WAY DRIVE PED. WARNING SIGNYELLOW THERMOPLASTICCROSSWALK & STOP BAR(SEE DETAIL C3.02) DO NOT ENTERSIGN NORTH 1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" 1.ALL PAVEMENT SECTION MATERIALS AND INSTALLATION SHALL MEET THE STATEDEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS (LATESTEDITION).2.GRADED AGGREGATE BASE COURSE SHALL MEET THE REQUIREMENTS OF THESTATE DEPARTMENT OF TRANSPORTATION STANDARD SPECS (LATEST EDITION).3.ASPHALTIC CONCRETE SHALL BE A PLANT MIX MEETING THE REQUIREMENTS OFTHE STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECS (LATESTEDITION).THE JOB MIX SHALL MEET THE REQUIREMENTS OF THE STATEDEPARTMENT OF TRANSPORTATION STANDARD SPECS (LATEST EDITION), ANDSHALL HAVE A MARSHALL STABILITY OF 1250 POUNDS AND A PERCENT VOIDSBETWEEN 4 AND 5.4.PAINTED PARKING STRIPING SHALL BE 4" WIDE WHITE STRIPES AND BE LOCATEDAS SHOWN ON THE PLANS. HANDICAP PARKING STRIPING SHALL BE #154 LIGHTBLUE. DIRECTIONAL STRIPING, NO PARKING AREAS, AND CENTERLINES SHALLBE PAINTED YELLOW EXCEPT AS INDICATED IN PLANS. PAINT AND ALL WORKSHALL BE IN ACCORDANCE WITH THE STATE DEPARTMENT OFTRANSPORTATION STANDARD SPECS (LATEST EDITION).5.ALL PAINTED PARKING AREAS SHALL RECEIVE TWO COATS OF STATEDEPARTMENT OF TRANSPORTATION APPROVED PAINT.6.ALL PAVEMENT MARKINGS WITHIN THE RIGHT-OF-WAY SHALL BE OF THETHERMOPLASTIC OR EPOXY TYPE PER THE STATE DEPARTMENT OFTRANSPORTATION STANDARD SPECS (LATEST EDITION). PAVING AND MARKING NOTES: SITE PLAN C3.01 ACCESSIBILITY NOTES:1.ALL WORK SHALL MEET THE GUIDELINES OF THE MANUAL ON UNIFORMTRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION, THE AMERICAN WITHDISABILITIES ACT ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES(ADAAG), LATEST EDITION, AND ANY ADDITIONAL STATE OR LOCALREQUIREMENTS REGARDING ACCESSIBILITY.2.THERE SHALL BE A 5' "LEVEL" LANDING AREA AT THE EXTERIOR OF ALLDOORWAYS. FOR THIS PURPOSE, "LEVEL" SHALL MEAN THE SLOPE IN ANYDIRECTION, INCLUDING THE DIAGONALS, SHALL NOT EXCEED 1:50 (2.0%).3.CONTRACTOR SHALL ENSURE THAT THE DOORWAY THRESHOLDS MEETACCESSIBILITY REQUIREMENTS.4.LONGITUDINAL (RUNNING) SLOPES ALONG THE ACCESSIBLE ROUTE SHALL NOTEXCEED 1:20 (5.0%).5.CROSS SLOPES ALONG THE ACCESSIBLE ROUTE SHALL NOT EXCEED 1:50 (2.0%).6.SLOPES IN ANY DIRECTION, INCLUDING THE DIAGONALS, WITHIN THEACCESSIBLE PARKING SPACES OR ACCESS AISLES SHALL NOT EXCEED 1:50(2.0%).7.ALL EXTERIOR CONCRETE SURFACES SHALL RECEIVE A HEAVY BROOM FINISHFOR PEDESTRIAN SLIP-RESISTANCE.1.ALL ANGLES ARE 90° UNLESS OTHERWISE NOTED.2.ALL RADII ARE 5' UNLESS OTHERWISE NOTED.3.ALL DIMENSIONS TO CURB ARE TO FACE OF CURB UNLESS OTHERWISE NOTED.(i.e. ALL DIMENSIONS TO MOUNTABLE CURB ARE TO THE EDGE OF PAVEMENT)4.ALL DIMENSIONS ARE TO FACE OF BUILDING UNLESS OTHERWISE NOTED.5.ALL DIMENSIONS ARE HORIZONTAL MEASUREMENTS.6.SEE ARCHITECTURAL PLANS FOR EXACT BUILDING DIMENSIONS.7.SIDEWALKS ARE TO INTERSECT WITH A 2' RADIUS UNLESS OTHERWISE NOTED. LAYOUT NOTES: SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25LEGENDLEGEND: PROPOSED LIGHT USE PVMT GEOTECHNICAL PVMT RECOMMENDATIONS: PROPERTY BOUNDARYFIRE LANEADA ACCESSIBLE ROUTEGRAVEL PARKING / WALKWAYPROPOSED CONCRETESLAB / SIDEWALKPROPOSED HEAVY USE PVMTBIKE RACK 1.FOOD DISPOSAL/WASTE COLLECTION TO BE REMOVED FROM THE SITE DAILYAND DISPOSED PROPERLY.REFUSE DISPOSAL NOTE: Page 25 of 37 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 XXXXXXXXXXX LS FOOD PANTRY80' x 40'3,200 SFFFE: 12.5' COVERED ENTRYWAY RAISED PLANTER (REFER TO ARCH.) XXXSERVICE YARD (REFER TO ARCH.) PONDTOB: 9.75BOP: 7.502-YR EL: 8.1910-YR EL: 8.8525-YR EL: 9.17100-YR EL: 9.57 <<<<<<<<<< TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD TP TPTP TPTPTP TPTP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TPTPTPTPTPTPTP TPTP PB PBPBPBPBPB TP15' MAINTENANCE ESMT 15' MAINTENANCE ESMT 10 8 9 11 11 12 1213131414 109 11 1112 10 111213 16171718181512 13 14 10 11 109 GRADING IN TREE PROTECTIONZONE TO BE HAND GRADED 899899 899 99 10101111 111212 1011121091111 1112 1513 14 161712 89 11 8 12 1810 10 11 11.99 TP12.19 TP11.9 FG12.0 FG 11.78 TP11.83 TP12.34 TS12.34 TS12.50 TS12.34 TS12.34 TS 12.50 TS12.34 TP 11.10 FG10.80 FG10.80 TP11.00 TP 9.75 TP9.75 TP 9.75 TP10.09 TP 9.83 TP9.93 TP10.00 TP 12.07 TP 12.34 TP12.11 TP 11.40 FG11.44 FG11.86 FG10.07 TP10.32 TP11.00 TP 9.75 TP9.98 TP10.77 TP10.16 TP10.05 TP11.80 FG11.80 FG 11.80 FG11.80 FG 11.50 TP11.52 TP 11.10 FG 12.0 FG 12.0 FG 11.34 TP11.46 TP12.00 EX11.89 EX 11.46 TP11.45 TP11.23 TP11.45 TP11.25 TP11.58 TP11.63 TP 11.94 TP11.88 TP 10.98 TP10.86 TP 10.82 TP 17.00 FG17.00 FG17.58 HP17.61 HP11.80 FG11.80 FG 9.83 TP 12.0 FG PAD:12.5011.80 FG11.80 FG 11.0 FG11.9 FG PAD:12.5012.0 FG 11.79 EX 11.84 TP 9.84 FG9.80 FG10.99 FG 11.97 FG 11.38 FG11.44 FG 11.65 TP11.52 TP 11.62 TP 11.60 TP11.54 TP11.90 TP 11.00 FG TIE-IN TOEXISTINGDRIVE 11.24 TP 11.00 HP 11.50 HP 10.90 FL10.30 FL10.05 FL9.94 FL9.75 FL 11.00 LP10.20 LP9.65 LP8.89 LP 9.70 FG9.70 FG9.70 FG9.70 FG9.75 FG7.50 FG 7.50 FG 5' WIDE TOP OF BERM @ ELEV.: 9.75'4:1 MAX4:1 MAX4:1 MAX 11.99 HP12.18 HP 9.75 FG9.50 FG9.50 FG9.50 FG9.50 FG7.50 FG7.50 FG8.69 FG8.66 FG9.61 FG 11.89 TP11.68 TP NORTH 1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" GRADING NOTES:1.ALL LAND DISTURBING OPERATIONS SHALL BE IN ACCORDANCE WITH THESTORMWATER POLLUTION PREVENTION PLAN (SWPPP).2.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL HORIZONTAL ANDVERTICAL SURVEY CONTROLS.3.CONTRACTOR SHALL REMOVE ALL STRIPPINGS, DEBRIS AND EXCESSEXCAVATED MATERIALS FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER.4.THE CONTRACTOR IS RESPONSIBLE FOR ALL EXCAVATIONS AND GRADINGINCLUDING FURNISHING OFF-SITE BORROW AS REQUIRED TO MEET PLANGRADES.5.IF UNSUITABLE SUBGRADE MATERIALS ARE ENCOUNTERED, THE CONTRACTORIS RESPONSIBLE FOR REMOVAL AND REPLACEMENT (FROM OFF-SITE BORROWMATERIAL) OF ALL UNSUITABLE MATERIAL TO MEET COMPACTIONREQUIREMENTS UNDER PAVED SURFACES. UNSUITABLE MATERIALS ARE THOSECLASSIFIED AS MH, CH, OH, OL AND PEAT IN ACCORDANCE WITH THE UNIFIEDSOIL CLASSIFICATION SYSTEM, UNLESS APPROVED IN WRITING BY THE PROJECTGEOTECHNICAL ENGINEER. THE SITE ENGINEER AND GEOTECHNICAL ENGINEER,SHALL BE NOTIFIED IMMEDIATELY UPON ENCOUNTERING UNSUITABLESUBGRADE MATERIAL.6.CONTRACTOR SHALL UNIFORMLY GRADE BEHIND CURBS, BUILDINGS, ROADS,ETC. TO MATCH EXISTING GRADES. LANDSCAPE ISLANDS SHALL BE GRADED TODRAIN OVER CURBS.7.GRADE ENTIRE SITE TO PROVIDE POSITIVE DRAINAGE TO EXISTING OR NEWDRAINAGE FACILITIES.8.COMPACTION REQUIREMENTS ARE AS FOLLOWS OR AS STATED IN THEGEOTECHNICAL REPORT, WHICHEVER IS MORE STRINGENT:A.SUBGRADES UNDER PAVED AREAS AND STRUCTURES 100 PERCENTSTANDARD PROCTOR (ASTM 698) - 24 INCHES.B.UNPAVED AREAS TO BE GRASSED OR LANDSCAPED 95 PERCENTSTANDARD PROCTOR (ASTM D698) - FULL DEPTH10.CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING AS NECESSARY TO MEETREQUIRED EXCAVATIONS AND GRADES. DEWATERING OPERATIONS SHALL NOTDISCHARGE DIRECTLY INTO MARSH OR WETLAND AREAS. MUDDY WATER TO BEPUMPED FROM EXCAVATION AND WORK AREAS MUST BE HELD IN SETTLINGBASINS OR FILTERED PRIOR TO ITS DISCHARGE INTO SURFACE WATERS ORSTORM DRAINAGE SYSTEMS. WATER MUST BE DISCHARGED THROUGH A PIPE,WELL GRASSED OR LINED CHANNEL, OR OTHER EQUIVALENT MEANS SUCH THATDISCHARGE DOES NOT CAUSE EROSION OR SEDIMENTATION. SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25GRADING PLAN C4.01 SPOT SHOT LEGENDBWBOTTOM OF WALLEGEXISTING GRADEEG MATCHMATCH EXISTING GRADEFGFINISH GRADEFFEFINISH FLOOR ELEVATIONHPHIGH POINTLPLOW POINTPADFINISH PADTC BCTOP OF CURB AND BOTTOM OF CURBTCTOP OF CURBTGTOP GRATETPTOP OF PAVEMENTTSTOP OF SIDEWALKEXEXISTING STRUCTUREFLFLOW LINE Page 26 of 37 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE LOADING ZONE OPEN AIRPAVILION513-SF VAN XXXXXXXXXXX LS FOOD PANTRY80' x 40'3,200 SFFFE: 12.5' COVERED ENTRYWAY RAISED PLANTER (REFER TO ARCH.) XXXSERVICE YARD (REFER TO ARCH.) TPTPTPTPTPTPTPTPTPTPTPTPTPTPTPTP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD TP TPTP TPTPTP TPTP TPTPTPTPTPTPTPTPTPTPTPTPTPTPTP TPTPTPTPTPTPTP TPTP PB PBPBPBPBPB TP 25' TYPE C BUFFER 15' MAINTENANCE ESMT 15' MAINTENANCE ESMT 10 8 9 11 11 12 1213131414 109 11 1112 10 111213 16171718181512 13 14 10 11 109 899899 899 99 10101111 111212 1011121091111 1112 1513 14 161712 89 11 8 12 1810 10 11 6" PVC ROOF DRAIN CLEANOUTRIM: 11.086" PERF. PVC (SEE TRENCHDTL SHEET C5.04)1,440 SF GRAVEL PARKING LOT& INFILTRATION TRENCH OCS: 2'X2' GRATE INLET(OUTFALL STRUCTURE)RIM: 9.50IE: 7.67 (OUT, W)4" WQ ORIFICE IE: 7.756" WEIR IE: 8.752X2 GRATE INLET (w/ TRASH RACK) IE: 9.5020 LF 12" RCP @ 0.40% 18" MIN. THICK CLASS II (D50: 9")ROCK RIPRAP 10' WIDE EMERGENCY SPILLWAYIE: 9.5018" MIN. THICKCLASS II (D50: 9")ROCK RIPRAP DOWNSPOUT TO CONNECTTO STORM DRAINRIM: 11.77 16 LF WEIR @ 10.80' PIPE END: BPEIE: 7.59 (IN, E) SDSDSDSDSD SDSDSDSDSD PONDTOB: 9.75BOP: 7.502-YR EL: 8.1910-YR EL: 8.8525-YR EL: 9.17100-YR EL: 9.57 <<<<<<<<<< CO RDSDSDSDSDSDSDSD ROOF GUTTER TOCONNECT TO DOWNSPOUT DET. POND CROSS-SECTIONSCALE: 1" = 30' HORIZ, 1" = 3' VERT0 5 10 15 20 0 5 10 15 20 -0+200+000+501+001+502+002+20 2-YR WSEL: 8.1925-YR WSEL: 9.1710-YR WSEL: 8.85100-YR WSEL: 9.57EMERGENCY SPILLWAYELEV: 9.50TOP OF PONDELEV: 9.75TOP OF PONDELEV: 9.75 OCS: 2'x2' GRATE INLET(OUTFALL STRUCTURE)FRAME: 9.5012" RCP - IE: 7.67 (OUT, W)4" WQ ORIFICE IE: 7.756" WEIR IE: 8.752X2 GRATE INLET (w/ TRASH RACK) IE: 9.50 4" WQ ORIFICEIE/WQEL = 7.7520 LF 12" RCP @ 0.40%BOT. OF PONDELEV: 7.50EXISTING GRADE PIPE END: BPEIE: 7.59 TRASH RACK (SEEDETAIL SHEET C5.04)FINISHED GRADEWQEL: 7.759" THICK ROCK RIP RAP (D50:6") OUTFALL PIPE:Q25 = 0.83 CFSV25 = 2.39 FT/SD25 = 5.5 IN.Q2 = 0.19 CFSV2 = 1.58 FT/SD2 = 2.5 IN. 5' NORTH 1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" STORM DRAINAGE NOTES:1.ALL RCP PIPE SHALL BE CLASS III WATERTIGHT REINFORCED CONCRETE PIPEUNLESS OTHERWISE NOTED.2.ALL PVC STORM PIPE SHALL BE SDR-35 BELL & SPIGOT.3.ALL CORRUGATED PLASTIC PIPE (CPP) AND FITTINGS SHALL BE ADS N-12, WT ORAPPROVED EQUAL WITH WATERTIGHT CONNECTIONS.4.LOCATIONS AND TOP ELEVATIONS OF INLETS AND STRUCTURES WILL BEADJUSTED IN THE FIELD BY THE CONTRACTOR WHERE NECESSARY AND SHALLBE APPROVED BY THE ENGINEER.5.INVERTS SHOWN ON PLAN DRAWING ARE PIPE INVERTS.6.MAINTENANCE RESPONSIBILITY OF ALL STORM DRAINAGE PIPING ANDSTRUCTURES SHALL BE AS FOLLOWS:DURING CONSTRUCTION:GENERAL CONTRACTORAFTER CONSTRUCTION:OWNER7.SITE CONTRACTOR IS RESPONSIBLE FOR MAKING TIE-IN TO UNDER-SLAB ROOFDRAIN CONNECTIONS AT BUILDING. ALL BUILDING CONNECTION POINTS SHOWNARE FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM ALL BUILDINGCONNECTION POINT LOCATIONS AND ELEVATIONS WITH APPROVEDARCHITECTURAL AND MECHANICAL PLANS.8.SITE CONTRACTOR IS RESPONSIBLE FOR EXTENDING ROOF DRAIN LEADERS TOWITHIN 5 FEET OF BUILDING FOR CONNECTION OF EXTERNALDOWNSPOUTS/ROOF DRAINS. ALL CONNECTION POINTS SHOWN ARE FORREFERENCE ONLY. PLUMBING CONTRACTOR/GENERAL CONTRACTOR ISRESPONSIBLE FOR MAKING TRANSITION AND CONNECTION TO ROOF DRAINLEADERS. DRAINAGE PLAN C5.01SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25 16' WIDE (TYP)PERVIOUS PARKING INFILTRATION TRENCH DETAIL (NTS)MIN. TOP OF INFIL. TRENCH: 10.80' 2' 2.5" DEPTH CLEAN,AGGREGATE WITH MAX.DIAMETER OF 3.5 IN. AND AMIN. DIAMETER OF 1.5 IN.SAND BED 6" DEEPFILTER FABRIC(NON-WOVEN)BOTTOM OF TRENCH: 8.00'SEASONAL HIGH WATERTABLE ELEVATION: 7.00'4" OR 6" SCHEDULE 40 PERF. PVC PIPE (EZ-DRAIN PREFAB. FRENCH DRAIN), OR, 3" GRAVEL LAYEROF 0.5" TO 1.5" WASHED ROUNDED RIVER GRAVEL WRAPPED IN HIGH FLOW GETEXTILE FABRIC 1/8” THICK COMMERCIALALUMINUM PAVERRESTRAINTS OR ENGINEERAPPROVED EQUAL (MOUNT TOCONCRETE & USE TO SECURELINER)12" DEPTHCONC. HEADER 8" WIDE x 12" DEEPCONCRETE BORDER(PER STD. CURBSPECIFICATIONS)(OR ENGINEERAPPROVED EQUAL)6" THICK #57 STONE AGGREGATEOR ENGINEER APPROVED EQUAL 1/8” THICK COMMERCIALALUMINUM PAVERRESTRAINTS OR ENGINEERAPPROVED EQUAL (MOUNT TOCONCRETE & USE TO SECURELINER) 8" WIDE x 12" DEEP CONCRETEBORDER (PER STD. CURBSPECIFICATIONS)(OR ENGINEER APPROVED EQUAL) 2.80' DEPTH GRADE TO DRAIN PER DRAINAGE /GRADING PLAN (C4.01)GRADE TO DRAIN PER DRAINAGE /GRADING PLAN (C4.01) Page 27 of 37 30' BLDG STBCK30' BLDG STBCK30' BLDG STBCK 20' BLDG STBCK 25' TYPE C BUFFER25' TYPE C BUFFER 15' REDUCED TYPE C BUFFER 25' TYPE C BUFFER30' BLDG STBCK 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 25' TYPE C BUFFER TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE 55 10 10 15 154466 777 77 8 8 8 8 99 99 99 9 9 9 9 1111 11 11 12 12 13 13 14 14 1616 16 7777 7 88 8 9999 77 88 EX-021.04 STUDY POINT 1Q2 = 0.67 CFSQ10 = 1.55 CFSQ25 = 2.48 CFSQ100 = 4.58 CFS 10 8 9 11 11 12 1213131414 109 11 1112 10 111213 16171718181512 13 14 10 11 109 STUDY POINT 2Q2 = 9.31 CFSQ10 = 9.39 CFSQ25 = 9.47 CFSQ100 = 9.78 CFS EX-012.66 ADDITIONAL FLOW BASEDON FULL FLOW CAPACITYQ_25 = 9.24 CFS NORTH1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" DRAINAGE MAP 01 C5.02SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25 Tc (TIME OF CONCENTRATION)FLOW PATH BETWEEN BASINSSTORMWATER BASINFLOW ARROWLEGEND Page 28 of 37 20' WTLND BUFFERPOTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 TREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREETREE LOADING ZONE OPEN AIRPAVILION513-SF XXXXXXXXXXX LS FOOD PANTRY80' x 40'3,200 SFFFE: 12.5' COVERED ENTRYWAY RAISED PLANTER (REFER TO ARCH.) XXXSERVICE YARD (REFER TO ARCH.) SDSDSDSDSD SDSDSDSDSD PONDTOB: 9.75BOP: 7.502-YR EL: 8.1910-YR EL: 8.8525-YR EL: 9.17100-YR EL: 9.57 <<<<<<<<<< CO RDSDSDSDSDSDSDSD899899 899 99 10101111 111212 1011121091111 1112 1513 14 161712 89 11 8 12 1810 10 11 55 10 10 15 154466 777 77 8 8 8 8 99 99 99 9 9 9 9 1111 11 11 12 12 13 13 14 14 1616 16 7777 7 88 8 9999 77 88 STUDY POINT 1Q2 = 4.43 CFSQ10 = 8.79 CFSQ25 = 10.89 CFSQ100 = 14.38 CFSSTUDY POINT 2Q2 = 4.43 CFSQ10 = 8.79 CFSQ25 = 10.89 CFSQ100 = 14.38 CFS 10 8 9 11 11 12 1213131414 109 11 1112 10 111213 16171718181512 13 14 10 11 109 POST-01A0.54 POST-01B0.47 POST-01D1.79 POST-020.88ADDITIONAL FLOW BASEDON FULL FLOW CAPACITYQ_25 = 9.24 CFSPOST-01C0.11 DRAINAGE MAP 02 C5.03SHEET NO.NO.DESCRIPTIONBYDATEREVISIONS DRAWN BY:DESIGNED BY:CHECKED BY:Know what'sbelow.before you dig.Call RLOCATION OF EXISTINGUNDERGROUND AND OVERHEADUTILITIES ARE APPROXIMATELOCATIONS ONLY. THECONTRACTOR SHALL DETERMINETHE EXACT LOCATION OF ALLEXISTING UTILITIES PRIOR TOBEGINNING WORK AND SHALL BEFULLY RESPONSIBLE FOR ANY ANDALL DAMAGES WHICH MIGHT OCCUR. RJSJJRMESDATE:JOB NUMBER:SC6478-2501 SOUTH CAROLINACERTIFICATE OF AUTHORIZATIONNo. C06168LJA ENGINEERING, INCSANDALWOOD FOOD PANTRYTOWN OF HILTON HEAD ISLANDCONSTRUCTION PLANSLJA Engineering, Inc.Charleston, South Carolina 29401171 Church StreetSuite 100Phone 843.507.8404www.LJA.comFRN-CO6168 10/28/25 10-28-25 NORTH1 INCH =GRAPHIC SCALE0FT20102020NOTE: THIS SCALE APPLIESFORSHEETS ONLY24"x36" Tc (TIME OF CONCENTRATION)FLOW PATH BETWEEN BASINSSTORMWATER BASINFLOW ARROWLEGEND Page 29 of 37 Page 30 of 37 Page 31 of 37 Page 32 of 37 Luminaire ScheduleSymbolQtyLabelArrangementDescriptionTagLLFLuminaireLumensLuminaireWattsTotalWatts 2AUTOBAHN SMALLSingle250EQ LED 3000K AT 20' MOUNTINGHEIGHT ON 25' POLE0.72013109102204 Luminaire Location SummaryInsertion PointLumNoLabelXYZOrientTilt 1AUTOBAHN SMALL208315913787820236.4970 2AUTOBAHN SMALL2083154.805137807.86220149.8860 Calculation SummaryLabelCalcTypeUnitsAvgMaxMinAvg/MinMax/Min CalcPts_1IlluminanceFc1.433.90.28.2019.50 Shielded AreaIlluminanceFc0.000.00.0N.A.N.A. 0.30.4 0.40.30.30.2 0.20.50.91.52.12.2 0.60.60.6 0.30.61.11.82.8 2.11.11.0 0.20.40.91.52.22.83.43.43.32.92.41.91.3 0.40.71.11.62.12.62.93.13.43.2 0.61.01.32.02.93.73.7 0.30.51.42.63.83.9 0.41.22.53.6 0.41.42.63.2 0.51.42.22.6 0.51.01.40.80.00.00.00.00.00.00.00.00.0 0.00.00.00.00.00.00.00.00.0 LOADING ZONE OPEN AIRPAVILION513-SF FOOD PANTRY80' x 40'3,200 SFFFE: 12.5' COVERED ENTRYWAY RAISED PLANTER (REFER TO ARCH.) SERVICE YARD (REFER TO ARCH.) ONE WAYONE WAY TEL VAULT BREAKER PANEL BREAKER PANEL DIRT ROAD DIRT ROAD MVMMVM 3' POST W/ROPE 3' POST W/ROPE NV. OUT: 7.27'I NV. OUT: 7.35'IN:7.40'INV.IM: 10.90'IRIEX. G 24" RCP (REF PLAT #3)NE EASEMENTIPOWERL 25' TYPE C BUFFER 25' TYPE C BUFFER 15' REDUCED TYPE C BUFFER 25' TYPE C BUFFER 25' TYPE C BUFFER N/FTHE TOWN OF HILTON HEAD ISLAND(D.B. 2159, PG. 90730' BLDG STBCK 30' BLDG STBCK 30' BLDG STBCK 20' BLDG STBCK 30' BLDG STBCK 10' PERMANENTRIGHT-OF-WAY AND EASEMENT(PER REF. PLAT #5) .N.I I.N. I.N. I.N. I.N. I.N. I.N. 3" CONC. O. 20' WTLND BUFFER POTENTIAL WTLND PER NEWKIRKENV. INC. ASSESSMENT ON 9/19/24 VAN 5' CHAIN LINK FENCE 5' CHAIN LINK FENCE 5' CHAIN LINK FENCECPLS #3 PN 14#1 WO 14 #4 PN 19 #5 WO 18 #56 PN 9 #50 GUM 9#51 PN 24 #54 PN 17 #55 PN 14 #53 GUM 8#52 GUM 8 #42 LO 38 #41 POP 19 #40 POP 8 #39 POP 17 #33 WO 23 #30 MAP 10 #29 WO 13 #23 PN 33#18 PN 12 #19 WO 12 #17 PN 31 #28 WO 15 #21 PN 20 #20 GUM 18 17 #6 GUM 9#7 GUM 9 #32 PN 26 15" RCP NV. OUT: 7.45'IN:7.60'INV.IM: 10.35'IRIEX. G 18" RCPNV. OUT: 7.23'I NOTES1. P.E.C.I. ONLY PROVIDES LIGHTING DESIGNS AS REQUESTED BY THECUSTOMER OR AS REQUESTED BY LOCAL GOVERNING AGENCIES.2. IT IS THE RESPONSIBILITY OF THE CUSTOMER TO ENSURE THAT THELIGHT VALUES, LOCATIONS, LIGHT TYPE, POLE TYPE, AND MOUNTINGHEIGHT ARE IN COMPLIANCE WITH ALL LOCAL GOVERNING AGENCYREQUIREMENTS AND/OR RECOMMENDATIONS.3. ANY OBSTRUCTIONS, OR THE INTRODUCTION OF, WITHIN THELIGHTED SPACE MAY PRODUCE RESULTS THAT ARE DIFFERENT FROMTHE PREDICTED VALUES.THESE PLANS ARE FOR THE APPROVAL AND CONSTRUCTION OFPALMETTO ELECTRIC COOPERATIVE, INC. OUTDOOR LIGHTS ONLY.COPYRIGHT: PALMETTO ELECTRIC COOPERATIVE INC.ALL RIGHTS RESERVED. THESE PAGES ARE PROTECTED BY UNITEDSTATES AND INTERNATIONAL LAWS. UNAUTHORIZED COPYING,DISTRIBUTION, ALTERATION OR USE BY ANY MEANS IS STRICTLYPROHIBITED. AUTOBAHN SMALL LEDAPPLICATIONSWalkways, driveways, malls,shopping centers, commercial and industrialcomplexes, and residential areas.SPECIFICATIONSUL1572 Listed Suitable for Wet LocationsHeavy-duty die-cast aluminum housing and doorPolyester powder finish standard in dark bronzeFull Cut Off FixtureSHIELDED AREA Page 33 of 37 Page 34 of 37 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 8 August Lane – Sandlewood Food Pantry DRB -001075-2025 DATE: 11/12/2025 CATEGORY: Final RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 35 of 37 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Provides Landscaping of a scope and size that is in proportion to the scale of the development Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provides overall order and continuity of the Landscape plan Page 36 of 37 3 Native plants or plants that have historically been prevalent on the Island are utilized A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommend approval of the Final submittal for 8 August Lane, Sandlewood Food Pantry with the following conditions: 1. Any additional information as required by the Board. Page 37 of 37

Source: Town of Hilton Head Island website. First collected Oct 26, 2026.