Historic District Review Board — Agenda Packet
City of Beaufort · Beaufort County · Historic District Review Board · meeting of Aug 13, 2025 · Agenda packets
Open the original document More from City of Beaufort
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Please click the link below to access the webinar:
https://us02web.zoom.us/j/88907423606?pwd=mWUgZIZJZLD4bIOFTcMz6UBTQTOADv.1
Password: 588094 Meeting ID: 889 0742 3606 Call in Phone #: 1+929 205 6099
City of Beaufort
1911 Boundary Street
Beaufort Municipal Complex
Beaufort, South Carolina 29902
(843) 525-7070
Historic District Review Board Regular Meeting Agenda
August 13, 2025
Statement of Media Notification
"In accordance with South Carolina Code of Laws, 1976, Section 30-4-80(d), as amended, all
local media was duly notified of the time, date, place and agenda of this meeting."
Regular Meeting - Council Chambers, 2nd Floor - 2:00 PM
Please note, this meeting will be broadcast via zoom and live-streamed on Facebook. You
can view the meeting at the City's page; City Beaufort SC
I. Call to Order
II. Minutes
A. May 14, 2025 Meeting Minutes
B. June 11, 2025 Meeting Minutes
C. July 9, 2025 Meeting Minutes
III. Applications
A. 404 Scott Street, PIN R120 004 000 0809 0000, addition
Applicant: Thomas Rhodes, Architect
IV. Discussion
V. Adjourn
Page 1 of 39
1
Historic District Review Board
Meeting Minutes – May 14, 2025
CALL TO ORDER 0:02
A meeting of the Historic District Review Board was held in-person on Wednesday, May 14 at 2:00 pm.
ATTENDEES
Members in attendance: Eric Berman, (Vice-Chair), Rita Wilson, and Kim Petrella
Member absent: Mike Sutton (Chair) and Grady Woods.
Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community
Development Planner, III, Nick Navia, Community Development Planner, I, Meadors Architects, and Julie A.
Bachety, Community Development Administrative Assistant II.
REVIEW OF MINUTES OF APRIL 9, 2025 0:05
Mr. Berman commented that on page 2 under the motion the second bullet 9’1”2 should be corrected to
either state 9 ½ feet or 9’ 6”. He also noted on page 2 under the motion the third bullet, conquer should
be corrected to “concur”.
Motion: Ms. Wilson made a motion to approve the April 9, 2025 minutes with the changes as noted.
Ms. Petrella seconded the motion. The motion passed unanimously.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
APPLICATIONS 1:14
A. 1203 Bay Street (The Cuthbert House), PIN R120 004 000 771A 0000, awning replacement
Applicant: Chris Ramm, Owner
The applicant is requesting approval for replacement of a green canvas awning at the rear of
The Cuthbert House with a standing seam metal shed roof.
Christopher Klement presented the staff report.
Page 2 of 39
2
Public Comment:
Wallace Scarborough, 1207 Bay Street thanked the Board and said what they are doing is
important and keeping the historic integrity of these homes is vitally important to the economy
of Beaufort and that is why tourists come here. Mr. Scarborough is in favor of the project.
Lise Sundrla, Historic Beaufort Foundation (HBF), stated HBF is in support of the project.
Public comment closed.
Motion: Ms. Petrella made a motion to approve alternative #2 – Shed-roof awning, option 1 as
presented by staff. Ms. Wilson seconded the motion. The motion passed unanimously.
B. 1107 Prince Street, PIN R120 004 000 0503 0000, alterations, additions 17:13
Applicant: Benjie Morillo, Architect
The applicant is requesting approval to partially demolish some walls within the existing
structure, as to add-on to the existing house, including changes to front, side/rear porches and
terrace.
Nick Navia presented the staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF), said HBF is in favor of the project. Ms.
Sundrla commented that the building was mis-aged when it was surveyed and portions of it are
actually the 1940’s. Ms. Sundrla suggested keeping the character defining features.
Daniel Blackman, 1010 Duke Street said he is in favor of the project for renovations of the
house. He wanted clarification that this application does not include the ADU or the other
addition because the plans show them as “future addition” don’t show it this way. He is
concerned about the vertical board and batten versus horizontal; it’s very unusual in the
Northwest Quadrant (NWQ) and not consistent with the NWQ.
Public comment closed.
Motion: Ms. Petrella made a motion to preliminarily approve the application with staff’s
recommendations and to add the additional condition that the applicant restudy the siding, the
windows, consider a gable return for the front addition and that their submission explicitly
excludes the future addition and future ADU. Ms. Wilson seconded the motion. The motion
passed unanimously.
ADJOURNMENT 50:38
Ms. Wilson made a motion seconded by Ms. Petrella to adjourn. The meeting ended at 2:51 pm.
Page 3 of 39
1
Historic District Review Board
Meeting Minutes – June 11, 2025
CALL TO ORDER 0:52
A meeting of the Historic District Review Board was held in-person on Wednesday, June 11, 2025 at 2:00
pm.
ATTENDEES
Members in attendance: Mike Sutton (Chair), Rita Wilson, Kim Petrella, and Grady Woods (via Zoom)
Member absent: Eric Berman, (Vice-Chair),
Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community
Development Planner III, Nick Navia, Community Development Planner, I, Meadors Architects, and Julie A.
Bachety, Community Development Administrative Assistant II.
REVIEW OF MINUTES OF MAY 14, 2025 0:59
Chairman Sutton stated the minutes of the May 14, 2025 meeting today will be placed on the Board’s
next meeting for review since there is not a full board.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
APPLICATIONS 1:24
A. Permit Extension: 1114 Congress Street: Request for a one-year COA extension for the COA.
Applicant: Cherimie Crane Weatherford, Executive Director, Freeman’s Arts District
The applicant is requesting approval for a one-year COA extension for the COA.
Curt Frreese stated the applicant is requesting a one-year extension for their COA. Mr. Freese
referred to Section 9.1 that states, COAs are given two years and then the COA can be renewed
for one year periods five times, but it has to come before the Historic District Review Board
(HDRB) to be approved. The applicant has not started on the project, but it was approved two
years ago, and staff sees no reason why it cannot be renewed.
Public Comment:
Page 4 of 39
2
None.
Public comment closed.
Motion: Ms. Petrella made a motion to approve the extension as requested. Ms. Wilson
seconded the motion. The motion passed unanimously.
B. 314 Charles Street, PIN R120 004 000 849B 0000, alterations 3:50
Applicant: Scott Haupt and Marilyn Marino, owners
Grady Woods recused himself from this project.
The applicants are requesting approval to install two (2) storm doors – 1 on the front and 1 on
the rear door of their home.
Nick Navia presented the staff report.
Public Comment:
Lise Sundrla, Director of Historic Beaufort Foundation (HBF), agrees with staff’s
recommendation. This is an important structure. Ms. Sundrla referred to the Preservation
Manual. She provided the applicant a recommendation for whoever to go to look for wooden
storm doors that was recommended by Jeremy Tate, Staff Architect. Keeping it as wood will go
a long way with showing best practices for what to do with historic structures. Ms. Sundrla
stated that we don’t look at a mistake that was made previously and use that as a precedent to
go forward.
Public comment closed.
Motion: Ms. Petrella made a motion to approve the aluminum example as presented today.
Ms. Wilson seconded the motion. The motion passed unanimously.
C. 914 Newcastle Street, PIN R120 004 000 0279 0000, new construction 18:02
Applicant: Megan Chancellor Crumrine, Architect
Mr. Woods returned to the Board now.
The Applicant is requesting approval for construction of a new single-family residence.
Christopher Klement presented the staff report.
Public Comment:
Lise Sundrla, Director of Historic Beaufort Foundation (HBF), said HBF is very pleased with the
changes that were made to minimize the height and scale of the building.
Public comment closed.
Motion: Mr. Woods made a motion to grant final approval with staff looking at the chimney cap
if there are any alterations. Ms. Petrella seconded the motion. The motion passed
unanimously.
Page 5 of 39
3
Mr. Freese said that the HRB/Planning Commission Subcommittee has been 42:40
meeting, and they are making some good progress. Mr. Freese asked the board members if
they want to do a Fall Tour possibly in October. He also asked if the board members would be
interested in future training.
ADJOURNMENT 45:46
Ms. Petrella made a motion seconded by Ms. Wilson to adjourn. The meeting ended at 2:45 pm.
Page 6 of 39
1
Historic District Review Board
Meeting Minutes – July 9, 2025
CALL TO ORDER 1:18
A meeting of the Historic District Review Board was held in-person on Wednesday, July 9, 2025 at 2:00 pm.
ATTENDEES
Members in attendance: Mike Sutton (Chair), Eric Berman, (Vice-Chair), and Grady Woods.
Member absent: Rita Wilson and Kim Petrella.
Staff in attendance: Curt Freese, Community Development Director, Christopher Klement, Community
Development Planner III, Meadors Architects, and Julie A. Bachety, Community Development Administrative
Assistant II.
REVIEW OF MINUTES OF MAY 14, 2025 1:30
Chairman Sutton stated the minutes of the May 14, 2025 meeting will be deferred to the Board’s next
meeting due to the lack of board members.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
REVIEW OF MINUTES OF JUNE 11, 2025 1:31
Chairman Sutton stated the minutes of the June 11, 2025 meeting will be deferred to the Board’s next
meeting due to the lack of board members.
All Historic District Review Board Meeting minutes are recorded and can be found on the City’s website at
http://www.cityofbeaufort.org/AgendaCenter.
APPLICATIONS 1:55
A. 1405 Duke Street, PIN R120 004 000 0345 0000, addition
Applicant: Martin W. Nash, homeowner
The applicant is requesting approval to build a screened-in detached adobe (200 sq. ft.) on an
existing platform at the rear of the existing house.
Page 7 of 39
2
Curt Freese said regarding this project, when the packages went out on Thursday before the
Fourth of July holiday, it was discovered by Historic Beaufort Foundation (HBF) that they hold an
easement on this property and that easement requires the applicant to obtain approval for any
major changes and HBF has not made that approval. Mr. Freese recommends the Board defer the
project. The applicant was present, but then left.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF) Director, said the project actually started with
the applicant submitting an incomplete application. Then additional documents were submitted by
the applicant yesterday and our Committee did not have time to review them.
Public comment closed.
Motion: Mr. Berman made a motion to defer the 1405 Duke Street project, and the Board will
have some discussion about this at the end of the meeting. Mr. Woods seconded the motion. The
motion passed unanimously.
B. 605 Carteret Street, PIN R120 004 000 0637 0000, alterations
7:48
Applicant: Zach and Rihanna Graber, homeowners
The applicants are requesting approval for minor exterior changes, including a new front door,
shutters, exterior paint color change and installation of gutters around the roof.
Christopher Klement presented the staff report.
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF) Director, said HBF is in support of staff’s
comments. However, it would be more in keeping with the style of the house not to choose the
white paint color with the black surrounds around the windows. The building was built ca. 1880 in
a similar style and form as to our Rainbow Row by George Holmes on Craven Street and during the
Vernacular Period of our Victorian style with more of a pastel coloring.
Public comment closed.
Motion: Mr. Berman made a motion to approve with staff recommendations with the addition
that the two vertical panel door was recommended and we’re approving it as it is presented but if
the applicant decides to change exterior paint colors to a pastel palette that it can be approved at
the staff level. Mr. Woods seconded the motion. The motion passed unanimously.
C. 807 Scott Street, PIN R120 004 000 0425 0000, exterior renovations
23:20
Applicant: Mirjam Kauffman for Stuart Feldman
The Applicant is requesting approval on various interior and exterior renovations/alterations,
including changing location of existing door/window at rear elevation, placement of new windows,
exterior paint color change as well as screened-in porch enclosure.
Christopher Klement presented the staff report.
Page 8 of 39
3
Public Comment:
Lise Sundrla, Historic Beaufort Foundation (HBF) Director, said HBF is supportive with staff’s
comments with the same caveat with the color of the house and is ca. 1885. It does have an
extinctive bay window on it. Ms. Sundrla suggested the applicant go in the direction of the pastel
colors for the base, HBF feels it would be more appropriate than the white, but a secondary
opportunity is to do the white base and then highlight the trim with a pastel.
Public comment closed.
Motion: Mr. Berman made a motion to approve with staff recommendations. Mr. Woods
seconded the motion. The motion passed unanimously.
D i s c u s s i o n
1:03:12
The Board discussed conservation easements and the process. If there is a property with a
conservation easement, how do we know before it’s too late, the Board asked. Mr. Berman stated
it should be filed with the Register of Deeds. Ms. Sundrla said typically she will know before
meeting with the client. Chairman Sutton suggested Ms. Sundrla give the Board an informal
training on Easements. Mr. Freese suggested making this topic part of the Fall tour/session.
ADJOURNMENT 1:11:27
Mr. Woods made a motion seconded by Mr. Berman to adjourn. The meeting ended at 3:10 pm.
Page 9 of 39
City of Beaufort
Department Request for Historic District Review Board Agenda Item
To: Historic District Review Board Date: 08/06/2025
From: Nicolas Navia, Community Development Planner I
Item Name: 404 Scott Street, PIN R120 004 000 0809 0000, addition
Applicant: Thomas Rhodes, Architect
Meeting Date: August 13, 2025
Department: Community Development Department
Background Information:
Introduction:
The applicant is requesting approval for an addition of a covered porch, with a brick walkway
leading out to the sidewalk, new shutters, new siding, and new living fence. Existing windows
and shingle roof to remain; porch roof to be a standing seam metal roof that will tie into existing
shingle roof.
Background:
The applicant is requesting approval for a covered porch (182 sqft) located at the front of the
existing ca. 1960 1-story structure. The project consists of the covered porch with a green
standing seam metal roof, a new brick walkway leading to the sidewalk, new shutters, new
siding, and a new living fence. The existing wood windows and asphalt shingle roof are to
remain. The porch’s standing seam metal roof is to tie into the existing shingle roof. The
applicant has been to one (1) HTRC Meeting on July 2nd, 2025.
Legal Authority:
S.C. Code Ann. § 6-29-310 et seq. Comprehensive Planning Enabling Act
Staff Recommendation:
Staff is supportive of the overall project, in that it satisfies the intent of the Beaufort
Preservation Manual. However, following aspects should be clarified before considering
FINAL APPROVAL:
1. Staff recommends selecting a different color for the standing seam metal roof. Staff
has concerns that the “Patina Green” color selected by the applicant will appear too
different in color next to the existing dark gray asphalt shingle roof, even though it
Page 10 of 39
is a low-slope roof. Staff recommends selecting a gray color to match the existing
roof. Staff is supportive of the siding/trim/window color, shutter color, and porch
ceiling color.
2. Applicant is proposing fiberglass shutters. Staff may be supportive of fiberglass
shutters since this structure is non-contributing, but requests a sample or mockup of
a shutter to better understand the appearance of the shutter.
3. The proposed shutters at the ganged window on the front (east) façade do not
appear to be wide enough to cover the width of the windows. Staff recommends
using bi-fold shutters at these windows with a longer shutter dog to accommodate
both panels.
4. Staff recommends reducing the depth of the eave at the front of the porch from 2’-
0” to 1’-6” or shorter to better match the eave depths on the existing structure.
Placed on Agenda For:
Action
Attachments:
1. Combined File
2. HRB Staff Report_404 Scott Street
Page 11 of 39
CITY OF BEAUFORT
UTH CAROLI
HISTORIC REVIEW APPLICATION
MAJOR REVIEW (HISTORIC REVIEW BOARD)
Community Development Department
1911 Boundary Street, Beaufort, South Carolina, 29902
p. (843) 525-7011 / f. (843) 986-5606
Email: development@cityofbeaufort.org / Website: www.cityofbeaufort.org
Application Fee:
see attached schedule
OFFICE USE ONLY: Date Filed:
*Non-Cont
81-25 Application #: 39157
Zoning District: T4-N
HAS PROJECT ATTENDED HTRC MEETING? (REQUIRED)☑YES ☐NO
IS PROJECT A CONTRIBUTING STRUCTURE?
Ο OR NON-CONTRIBUTING STRUCTURE: ✓
FOR A LIST OF CONTRIBUTING OR NON-CONTRIBUTING STRUCTURES, PLEASE SEE:
https://cityofbeaufort.org/350/Beaufort-County-Historic-Sites-Survey
APPLICABILITY FOR HISTORIC REVIEW BOARD: Major discretionary review board (HDRB) approval shall apply
to applications for Certification of Appropriateness per Section 9.10.2 for the following requests (please check all that apply):
☐New building(s) in Historic District
☐Changes to exterior materials of Contributing Structures
☐ Additions to Contributing Structures
Non-similar roof replacement on Contributing Structures (roof with different materials)
☐Window replacements on Contributing Structures
☑Major changes to a Contributing or Non-contributing Site
Demolition
☐Other changes to exterior of Contributing Structures
SUBMITTAL REQUIREMENTS: All forms and information shall be submitted digitally + 5 hard copies of all documents. In
addition to a complete application form, applicants shall submit the required items according to the checklists on the subsequent page.
Pursuant to Section 6-29-1145 of the South Carolina Code of Laws, is this tract or parcel restricted by any recorded covenant
that is contrary to, conflicts with,or prohibits the activity described in this application? Yes ☑ No
APPLICANT, PROPERTY, AND PROJECT INFORMATION:
APPLICANT NAME: Thomas Rhodes, AIA
APPLICANT ADDRESS: 38 Meridian Road, Beaufort, SC 29907
APPLICANT E-MAIL: tom@f-farchitects.com APPLICANT PHONE NUMBER. (843) 522-8422
APPLICANT TITLE: ☐ Homeowner Tenant ☑Architect Engineer Developer
Page 12 of 39
ITY OF BEAUFOR
OUTH CAROLI
HISTORIC REVIEW APPLICATION
MAJOR REVIEW (HISTORIC REVIEW BOARD)
Community Development Department
1911 Boundary Street, Beaufort, South Carolina, 29902
p. (843) 525-7011 / f. (843) 986-5606
Email: development@cityofbeaufort.org / Website: www.cityofbeaufort.org
Application Fee:
see attached schedule
Hannah Fulton
OWNER (IF OTHER THAN THE APPLICANT):
404 Scott Street, Beaufort, SC 29902
OWNER ADDRESS:
PROPERTY ADDRESS:. same
PROPERTY IDENTIFICATION NUMBER (TAXMAP PARCEL NUMBER): R120 004 000 0809 0000
PROVIDE A BRIEF PROJECT NARRATIVE: (Attach any necessary documentation, spec sheets, pictures, paint swatches, etc.):
Addition of covered porch, brick walk to sidewalk
New shutters, new siding, new living fence
Existing shingle roof to remain, new roof over porch to be standing seam metal
CERTIFICATION OF CORRECTNESS: I/we certify that the information in this application is correct.
Thomas Rhodes
APPLICANT'S SIGNATURE:
OWNER'S SIGNATURE: Hannah Fulton
(The owner's signature is required if the applicant is not the owner.)
DATE: 8/1/25
DATE: 8/1/25
SCHEDULE:
The Historic Review Board (HRB) typically meets the 2nd Wednesday of each month at 2pm. Staff will schedule
HRB meeting after HTRC and review of application submittal for completeness and compliance with the
Beaufort Preservation Manual and the City of Beaufort Development Code.
CONTACT INFORMATION:
City of Beaufort Community Development Department
1911 Boundary Street, Beaufort, South Carolina 29902
E-Mail: development@cityofbeaufort.org Phone: (843) 525-7011 Fax: (843) 986-5606
Page 13 of 39
Page 14 of 39
Page 15 of 39
Page 16 of 39
Page 17 of 39
Page 18 of 39
Page 19 of 39
Page 20 of 39
Siding and Trim Color SW 7008 Alabaster
Shutter and Accent Color SW 6192 Coastal Plain
Porch Ceiling CSP-545 Sheer Bliss
Porch and Walk Brick = Cherokee Brick Dover Bluff - Georgia Classic Collection
Standing Seam Metal Roof = Patina Green (Sentriclad Architectural Metals - 4M)
Finish Selections
Roof = 4M Metal Standing Seam Roof w/ 1" Rib Height
Siding = 7-1/4" Hardie Plank Siding W/ 6" Exposure (Smooth Face)
Trim = TruExterior Trim (Smooth Finish)
Columns = 8x8 Hollow KDAT SYP Columns
Brick Paver = Cherokee Brick Thin Brick with Corner Shape at all Corners
Entry Door = Stained Stile and Rail Wood Door
Windows = Existing Windows to Remain - Apply new Sealant and Paint
Underside of Roof Deck = 1x6 Sq. Edge KDAT SYP T&G
Shutters = Atlantic Premium Shutters (Operable, Smooth Finish)
Material Selections
PROPERTY ID (PIN): R120 004 000 0809 0000
SITE INFORMATION
TOTAL LOT SIZE................................1,501 S.F.
ZONING AND FLOOD INFORMATION
ZONED T4-N
NONCONTRIBUTING STRUCTURE
FLOOD ZONE = X SHADED
EXISTING F.F.E. = 9.33' (1988 NAVD)
MAIN HOUSE AREA
EXIST. FIRST FLOOR.......................723 S.F.
FRONT PORCH.................................182 S.F.
2025 All Rights ReservedC
1
A4.3
1
A4.1
1
A5.1
1
15.75'
A
1
1
GYPSUM WALLBOARD
(LARGE SCALE)
ACOUSTIC TILE
CARPET & PAD
GYPSUM WALL BOARD
(ELEVATION)
FLASHING, ETC
BRICK (ELEVATION)
HORIZONTAL SIDING
(ELEVATION)
ROOF SHINGLES
(ELEVATION)
WATERPROOFING, FELT,
CONTINUOUS
BLOCKING
ROUGH LUMBER
ROUGH LUMBEREARTH
GRAVEL
FINISH WOOD
INSULATION BATTS
RIGID INSULATION
PLYWOOD (LARGE SCALE)
PLYWOOD (SMALL SCALE)
CONCRETE
C.M.U.
BRICK
STEEL
DETAIL-NO.
SHEET-NO.
ENLARGED
DETAIL INDICATOR
SHEET-NO.
DETAIL-NO.
SECTION CUT INDICATOR
INTERIOR ELEVATION INDICATOR
WINDOW MARK
DOOR MARK
ELEVATION ABOVE MEAN SEA LEVEL
DETAIL-NO.
SHEET-NO.
OR OTHER SPECIFIED DATUM
WALL TYPE
REVISION NUMBER
Refrigerator
Roof Drain
Radius
Riser
Room
Roof Joist
Required
Revision
Reinforcing
Rough Opening
Sheet
Shelf
Schedule
Square Foot
Square
Specification
Similar
Solid Masonry Pier
Stainless Steel
Solid Core Wood
Telephone
Tread
Suspended
Steel
Top of Steel
Through
Threshold
Thick
Top of Plate
Typical
Top of Slab
Without
Wood
With
Vertical
Unless Otherwise Noted
Verify in Field
Vinyl Composition Tile
Top of Sheathing
Standard
Quanity
R.
Floor
Foot
FL.
F.D.
GA.
FT.
F.J.
Hose Bib
GYP.BD.
GALV.
H.M.
HCWD.
H.B.
Gauge
Hollow Metal
Gypsum Board
Galvanized
Floor Joist
Floor Drain
Hollow Core Wood
Height
Lavatory
Laminate
Kitchen
HGT.
HORIZ.
LAV.
LAM.
KIT.
Masonry
Light
Maximum
LT.
MAS.
MEMB.
MECH.
MAX.
Membrane
Mechanical
Horizontal
A.F.F.
ADJ.
ABV.
BD.
APPROX.
ANG.
ALT.
ALUM.
Board
Approximate
Angle
Alternate
Aluminum
Above Finish Floor
Adjacent
Above
BOT.
BSMT.
BM.
BLKG.
L
CLO.
CLG.
C.T.
C
CAB.
Closet
Ceiling
Ceramic Tile
Center Line
Cabinet
Bottom
Basement
Beam
Blocking
BuildingBLDG.
T.Minimum
MFR.
MET.
M.O.
MISC.
MIN.
N.I.C.
O.D.
O.C.
N.T.S.
Outside Diameter
On Center
Not To Scale
Not In Contract
Masonry Opening
Miscellaneous
Manufacturer
Optional
Plate
Precast
OPT.
OPNG.
PL.
P.LAM.
P.C.
Pair
Plywood
PR.
PLYWD.
P.S.I.
P.S.F.
P.T.
Pounds Per Square Inch
Pounds Per Square Foot
Pressure Treated
Plastic Laminate
Opening
CONC.
COL.
CMU.
C.O.
DIA.
D.F.
DTL.
DEPT.
CONT.
Dimension
Diameter
Drinking Fountain
Detail
Department
Continuous
Concrete
Column
Concrete Masonry Unit
Cased Opening
EA.
DWG.
DS.
DN.
EQUIP.
EQ.
EMER.
ELEC.
EL.
E.J.
Equipment
Equal
Emergency
Electrical
Elevation
Expansion Joint
Each
Drawing
Down Spout
Down
DIM.
Metal
CentimeterCM.
ExteriorEXT.
UON.
S.M.P.
REF.
W/O
WD.
W/
V.I.F.
VERT.
VCT.
TYP.
T.O.SL.
T.O.SH.
T.O.S.
T.O.P.
THRU.
THRES.
THK.
TEL.
SUSP.
STL.
STD.
S.S.
SQ.
SPEC.
SIM.
SHT.
SH.
SCWD.
SCHED.
R.O.
RM.
R.J.
REQD.
REV.
REINF.
R.D.
RAD.
QTY.
S.F.
Weight
Welded Wire Fabric
P.V.C. Polyvinyl Chloride
E.W.
EXIST.
Each Way
Existing
WWF
WT.
WaterproofingPainted WP.PTD.
SYMBOLS INDEX OF DRAWINGSSELECTIONSABBREVIATIONS
MATERIALS
EXTERIOR ELEVATION INDICATOR
A5.1
1
SHEET-NO.
DETAIL-NO.
LOCATOR MAP
3
24
Finished Room Over GarageFROG
NOT FOR
CONSTRUCTION
SITE INFORMATION
8/1/2025 3:08:24 PM A1.0 TITLE SHEET
FULTON PORCH
HRB
REVIEW
404 SCOTT STREET
BEAUFORT, SC
8/1/25
FULTON PORCH
404 SCOTT STREET
BEAUFORT, SC
Sheet Number Sheet Name
A1.0 TITLE SHEET
A2.0 FLOOR PLAN & PHOTOS
A3.0 EXTERIOR ELEVATIONS
A4.0 SECTIONS AND DETAILS
SURVEY SURVEY
Page 21 of 39
A3.05
A3.0
A3.0
A3.0
1
2
4
8
A4.0
New Living Fence
with Confederate
Jasmine
8' - 4"
21' - 4 1/8"1' - 4 1/2"
New Porch
(Brick)
Existing Walk
New Siding and Trim
over existing CMU 1' - 4 1/2"
Gate
New Brick Walk
Trash
4' - 3 1/4"6' - 0 7/8"6' - 0 7/8"8' - 7 3/8"
Swing
5' - 9 1/4"
EXISTING HOUSE
SCOTT STREET
NEIGHBORING ACCESSORY STRUCTURE
NEIGHBORING HOUSE
NEW PORCHEXISTING HOUSE
NEW PORCHEXISTING HOUSE
Property Line
New Living Fence
with Confederate
Jasmine
Turf Grass
Turf Grass
Zone = T4-N
2' - 10 3/4"
2
A4.0
A4.0
4
182 Sq. Ft.
723 Sq. Ft.
8
A4.0
2
A2.0
Sim
2
A2.0
Sim
2
A4.0
Sim
2X4 KDAT SYP Fascia
Half-Round Copper Gutter
2x Rafters @ 16" O.C.
1x6 Sq. Edge KDAT SYP T&G - Painted
1' - 0"
2' - 0"
1' - 0"
ROOF AS SPECIFIED
SHEATHING AS SPECIFIED
PEEL AND STICK MEMBRANE AS SPECIFIED
ELEC. CONDUCTOR
2X4 (FULL LENGTH OF RAFTER BAY)
FASTENED TO RAFTER AND DECK ABOVE
(ONLY WHERE REQ. FOR ELEC. FIXTURE)
EXPOSED RAFTERT&G DECKING
T&G DECKING
2X BLOCKING AS REQ. FOR FIXTURE
MOUNTING - POCKET SCREW TO 2X4s
2025 All Rights ReservedC
8/1/2025 3:08:27 PM
A2.0 FLOOR PLAN & PHOTOS
FULTON PORCH
HRB REVIEW
404 SCOTT STREET
BEAUFORT, SC
8/1/25
1/4" = 1'-0"3 FIRST FLOOR
Existing HouseScott Street and Existing House - Looking North WestScott Street and Existing House - Looking South West
N
1/4" = 1'-0"1 FIRST FLOOR CEILING AND ELECTRICAL PLAN
Light Fixture Schedule
Fixtur
e Tag Fixture Type Count Manufacturer Model Comments
A WALL SCONCE 1 The CopperSmith
Handcrafted Lighting
East Bay Collection EB20
B CEILING MOUNTED FIXTURE 1 Lowcountry Originals Carmel "By The Sea"
Chandelier
Sloped Ceiling
C CEILING FAN 1 MinkaAire F786-WHF Sloped Ceiling
1" = 1'-0"2 ELEC. CHASE IN PORCH CEILING
Page 22 of 39
New Operable Shutters
New Siding
New Standing
Seam Roof over
New Porch
(Patina Green)
New Copper Gutter
Gate
New Living Fence
with Confederate
Jasmine
Existing Roof To Remain
New Wall Sconce
New Entry Door - Ref. 4/A3.0
NEW PORCH EXISTING HOUSE
New Operable Shutters
New Siding
New Living Fence
with Confederate
Jasmine
New Standing
Seam Roof over
New Porch (Patina
Green)
Existing Vent
New Copper
Gutter
A4.0
7
2
A4.0
4
A4.0
Existing Roof
All Existing Wood
Windows to Remain
New Operable
Shutters
New Siding
New Living Fence
with Confederate
Jasmine
New Standing
Seam Roof over
New Porch (Patina
Green)
Existing Louvered Vent
New Copper
Gutter
2"
12"
NEW PORCHEXISTING HOUSE
A3.0
3
Existing Roof
All Existing Wood
Windows to
Remain
Siding and Trim Color SW 7008 Alabaster
Shutter and Accent Color SW 6192 Coastal Plain
Porch Ceiling CSP-545 Sheer Bliss
Porch and Walk Brick = Cherokee Brick Dover Bluff - Georgia Classic Collection
Standing Seam Metal Roof = Patina Green (Sentriclad Architectural Metals - 4M)
Finish Selections
FENCE HEIGHT
4'-0" MAX
2x4 Top Rail
3"x3"x1/4" Galv. Washer Spacer
4x4 Fence Post
1/2" x 1/2" Angle Frame (304 S.S.)
3"x3" McNICHOLS® Wire Mesh (304 S.S.)
2x4 Bottom Rail
Set post in Concrete
MIN.
1' - 4"
All Wood for Fence Must be KDAT SYP - Painted Siding Color
Insulated Glass
Panel
Insulated Glass
Panel
Square Sticking
TruExterior Casing
Stained Stile and
Rail Wood Door
5 1/2"
5 1/2"5 1/2"
9 1/4" 5 1/2"
3 1/2"3 1/2" 5 1/2"
1/A4.0 Sim.
6/A4.0 Sim.
MATCH EXIST.
MATCH EXIST.
2025 All Rights ReservedC
8/1/2025 3:08:31 PM
A3.0 EXTERIOR ELEVATIONS
FULTON PORCH
HRB REVIEW
404 SCOTT STREET
BEAUFORT, SC
8/1/25
1/4" = 1'-0"5 East
1/4" = 1'-0"2 West
1/4" = 1'-0"1 North
1/4" = 1'-0"4 South
1 1/2" = 1'-0"3 FENCE DETAIL
3/4" = 1'-0"8 ENTRY DOOR
KDAT Wood Fence - Painted "Alabaster"
Existing Architectural Shingle - Gray
4M Standing Seam Roof "Patina Green"
Hardie Plank Siding w/ 6" Exposure -
Smooth Surface - Painted "Alabaster"
TruExterior Trim Painted "Alabaster"
KDAT Hollow Columns Painted
"Alabaster"
Fiberglass Operable Shutters w/ Smooth
Finish - Painted "Coastal Plain"
Thin Brick Pavers and
Foundation Finish Cherokee
Brick "Dover Bluff"
Stained Sapele Entry Door
Page 23 of 39
FIRST FLOOR
0' - 0"
7-1/4" Hardie Plank Siding W/ 6" Exposure (Smooth
Face)
Thin Brick Set on Mortar Bed
A4.0
3
A4.0
5
2
A4.0
4
A4.0
A4.0
6
Sim
16" #5 @ 12" O.C.
Turned-Down Concrete Slab
KDAT 1x Attachment Strips @ 16" O.C. - Fasten to
CMU with Concrete Screws @ 16" O.C. Min.
1" Rigid Insulation (R-5)
2x6 PT Plate - Anchor to CMU w/ (2) 5/8" x 8" Bolt
per piece
2x6 Knee Wall
2x8 Rafters @ 16" O.C.
1x6 Sq. Edge T&G (KDAT, SYP, C&Better)
Simpson Strong-Tie H2.5A @ ea. Rafter
Cont. Blocking Btw. Rafters
1x TruExterior Trim Btw. Rafters
All Exposed Hardie and TruExterior Trim
and Siding Must have a Smooth Surface
2x10 Sleeper Fastened to ea. Exist. Rafter w/ (3)
16d Nails
Standing Seam Roof w/ 1" Rib Height
Existing Construction
Existing Construction
Toe-Nail ea. Rafter to Sleeper w/ (3) 16d Nails
8x8 KDAT Hollow Columns
2' - 0"
6
A4.0
1
A4.0
TruExterior Casing - Painted
New Operable Impact
Resistant Shutters -
Smooth Fiberglass -
Painted
Existing Wood Windows to
Remain - Seal and Paint
7-1/4" Hardie Plank
Siding W/ 6" Exposure
(Smooth Face) - Painted
5/4" TruExterior Skirt
Board - Painted
2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2"
4" Lag Pintel w/ Flat Hinge -
Typ.
"S" Holdback - Typ.
AZEK AZM75 Bed Moulding
8x8 KDAT Hollow Column
TruExterior Trim
1/8"
1 3/4"2 1/8"3/8"
5/8" Galv. Threaded Rod Inside Column
Align
Align
3"x3"x1/4" Galv. Washer and Nut
Wrap Beam W/ TruExterior Trim
7"
7"
Built-up Beam
Fasten Each Rafter to Beam W/ (2) 6" SDWC
Simpson Strong-Tie Screws
Half-Round Copper Gutter
2x4 KDAT Fascia-Rabbet as
Shown
1x6 Sq. Edge T&G (KDAT,
SYP, C&Better)
Standing Seam Roof (1" Rib Height)
2x8 KDAT SYP Rafters @ 16" O.C.
3/4"
3 1/2"
AZEK AZM93 Scotia
TruExterior Trim
1" 7"
1 1/2"
8x8 KDAT Hollow Column
Thin Brick set in
Mortar Bed
Concrete Slab /
Foundation
5/8" Galv.
Threaded Rod
Embedded 8"
MIN. in Concrete
Thin Brick Corner Shape
Along Perimeter
Extend Thin Brick to
Below Grade
AZEK AZM75 Bed Moulding
8x8 KDAT Hollow Column
TruExterior Trim
5/8" Galv. Threaded Rod Inside Column
3"x3"x1/4" Galv. Washer and Nut
Wrap Beam W/ TruExterior Trim
Built-up Beam
2x4 KDAT Fascia -
Rabbet as Shown
1x6 Sq. Edge T&G
(KDAT, SYP, C&Better)
Standing Seam Roof (1" Rib Height)
2x8 KDAT SYP Rafters @ 16" O.C.
1-5/8" x #8 Ext. Screw @
3" O.C. Staggered
1 1/4"
Align
1' - 0"
1
A4.0
Extend Thin Brick to
Below Grade
AZEK AZM-197 Drip Cap
TruExterior 5/4 Casing
Existing Wood Windows to Remain -
Seal and Paint
7-1/4" Hardie Plank Siding W/ 6"
Exposure (Smooth Face)
5/4" TruExterior Skirt
Board
4 1/2"
3 3/8"
Metal Flashing
KDAT 2x4
KDAT 1x4
KDAT 1x Attachment Strips @ 16" O.C. -
Fasten to CMU with Concrete Screws @
16" O.C. Min.
1" Rigid Insulation (R-5) - Tape All Seams
5/4 TruExterior Apron
2x TruExterior Sill
Fluid Applied Flashing
6
A4.0
Existing Wood Windows to Remain - Seal and Paint
Existing CMU WallExisting CMU Wall
4"
3/4" 3/4"
4"
1"
KDAT 2x4
5/4 TruExterior Casing KDAT 1x Attachment Strips @ 16"
O.C. - Fasten to CMU with
Concrete Screws @ 16" O.C. Min.2x TruExterior Sill Below
New Operable Impact Resistant Shutters
1" Rigid Insulation (R-5) - Tape all Seams
7-1/4" Hardie Plank Siding W/ 6"
Exposure (Smooth Face)
TruExterior Trim
Tape all Insulation Seams - Typ.
KDAT 1x Attachment Strips @ 16" O.C. -
Fasten to CMU with Concrete Screws @ 16"
O.C. Min. Existing CMU Wall
7-1/4" Hardie Plank Siding W/ 6" Exposure
(Smooth Face)
1" Rigid Insulation (R-5)
KDAT 1x Attachment Strips @ 16" O.C. -
Fasten to CMU with Concrete Screws @ 16"
O.C. Min.
Drainage Cavity
3 1/2"
3 1/2"
2025 All Rights ReservedC
8/1/2025 3:08:33 PM
A4.0 SECTIONS AND DETAILS
FULTON PORCH
HRB REVIEW
404 SCOTT STREET
BEAUFORT, SC
8/1/25
3/4" = 1'-0"8 SECTION AT PORCH
3/4" = 1'-0"7 WINDOW ELEVATION
1 1/2" = 1'-0"3 EAVE DETAIL
1 1/2" = 1'-0"5 BRICK EDGE AND COLUMN BASE
1 1/2" = 1'-0"2 RAKE DETAIL
1 1/2" = 1'-0"6 WINDOW HEAD AND SILL DETAIL
1 1/2" = 1'-0"1 WINDOW JAMB DETAIL
1 1/2" = 1'-0"4 CORNER BOARD DETAIL
Page 24 of 39
Page 25 of 39
9152 Hard Drive
Foley Alabama 36536
REV:A/0
LIMITS NOT SPECIFIED
FRACTION ± 1/32 - ANGULAR ± 1/2°
.0 ± .010 - .00 ± .005 - .000 ± .0025
MATL
ASSY
REVISION DESCRIPTION
DATE:04/18/2024
DRAWING BY:Jason Huang
APPD
APPD
QTY
JOB NO.
DATE
SCALE
NAME
DRAWING
NUMBER
SHEET
NUMBER
THIS DRAWING IS PROPERTY OF
THE COPPERSMITH INC. AND IS
SUBMITTED IN CONFIDENCE AND SHALL
NOT BE REPRODUCED, COPIED NOR DISCLOSED
TO OTHERS WITHOUT WRITTEN PERMISSION
FROM THE COPPERSMITH INC.
The CopperSmith (BDT)
EB-20E
Front View
Standard
back plate
3D Drawing for top spit caps
Right View
7-W4*L15 Slotted holes
on each side
203 [8"]
241 [9 1/2"]
137.5 [5 3/8"]
85°
114 [4 1/2"]394 [15 1/2"]
145.5 [5 3/4"]362.5 [14 1/4"]
508 [20"]
287.5 [11 3/8"]
Bottom post and door size
are all 12"or 13mm
Brass Arm
(14#)
CP-1GJ&
CB-1GJ
Page 26 of 39
Page 27 of 39
Name : Carmel "By The Sea" Chandelier
Item Number : LCO-KC-376
Dimensions : 61"L x 36"W x 38"H
Canopy : 6" Round
Material : Steel
Bulb/Wattage : 4/40C
Shown In : Aqua Marine Body
Finishes : Our light fixture finishes are designed to be as lively and ever-changing as the
Lowcountry landscape itself. Providing depth and characters to your custom design, our
finishes reflect the unique beauty of the coastal landscape and produces a beautiful,
natural patina as they age. Our nature-inspired finishes are truly a living art and not
only protect your piece, but create a amore beautiful luster with time.
Weight : 99 lbs
Description : The Carmel “by the Sea” Chandelier offers soft, elongated arms and timeless
form in round or oval styles. Understated and luminous, it's a versatile piece
that brings warmth and sophistication to any setting.
HEADQUARTERS • 6465 126th Avenue North • Largo, FL 33773 • US 888-743-9232
Page 28 of 39
Item #
F786-WHF
Product Family Name:
Simple
Category:
EXTERIOR FAN
Certification
4009339
UPC Code:
706411058684
Finish:
Flat White
Category Type:
Ceiling Fan
Patents:
Notes:
Image File Name: F786-WHF.jpg
MEASUREMENTS
Blade Finish:
Reversible Blades:
No
Blade Material:
ABS
Slope:
Yes
Blade Sweep:
44"
No. of Blades:
3
Blade Pitch:
26 DEGREES
Hanging Weight:
9.26
Downrod 1:
6
Downrod 1 Outside
Dia:
.75
Downroad 2:
Downrod 2 Outside
Dia:
Ceiling to Lowest
Point: (Dim A)
12.63
Ceiling to Blade
(Dim B)
11.25
Lead Wire:
8"
Motor Size:
DC 123x30mm
Low Low/Med. Medium Med/High High
RPM: 51 196
Amps: 0.06 0.59
Watts: 3.89 48.06
CFM: 1615.0 5323.0
CFM/Watts: 415.17 110.76
LAMPING
No. of Bulbs:
0
Light Type:
Light Kit Optional: Yes
Max Bulb
Wattage:
Socket:
Integrated
Light Kit: No
Dimmable:
No
Ballast:
Rated Life
Hours:
Uplight:
No
Bulb/LED
Included:
Color Temp.:
CRI: Initial Lumens:
Delivered
Lumens:
GLASS
Description:
Material:
Part No.:
Quantity:
Width:
Height:
Length:
CONTROLS
Pull Chain Control:
No
Works with Remote Control:
Yes
Works with Wall Control:
Yes
Reversible:
Yes
Included Remote Control:
RC400
Included Wall Control:
Smart Control:
No
Compatible Remote
Control(s):
Compatible Wall
Control(s):
WC400
Integrated Smart Control:
Compatible Smart Control:
BD-1000
SHIPPING
Carton Width:
8.63
Carton Height:
9.0
Carton Length:
22.75
Carton Weight:
11.0
Carton Cubic Feet:
1.023
Small Package Shippable:
Yes
Master Pack Width:
Master Pack Height:
Master Pack Length:
Master Pack Weight:
Master Cubic Feet:
Multi-Pack:
1
Master Pack:
1
ENERGY
STAR®
Wet
Location
ETL
Intertek
For additional information, please contact Customer Care: 1-800-221-7977 | Product depicted on this spec sheet is protected by United States Federal and/or State laws including US Patent,
Trademark and/or Copyright and unfair competition laws. Unauthorized reproduction or use carries severe legal penalties.
Rev 08.10.2022 09:01 AM
WARNING:Handling this product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands
with soap and water after installing, handling, cleaning or otherwise touching this product. For more information go to: www.P65Warnings.ca.gov.
Page 29 of 39
4
Designed to be used in non-load-bearing applications,
TruExterior Trim is suitable for ground and masonry contact
and moisture-prone areas, which makes it ideal for
exterior trim applications such as fascia, door trim,
soffits, rake boards and a variety of other applications.
There is no need to prime ends or field cuts. Plus,
it can be painted any color. TruExterior Trim
accepts common high-quality, exterior-grade
fasteners and can be installed using standard
woodworking tools and methods.
Trim
Page 30 of 39
3
Phenomenal Performance. Remarkable Workability.
TruExterior Siding & Trim offers both and a lasting look while eliminating the need for gluing, gapping and other
cumbersome and costly installation techniques.
*Please see TruExterior Siding & Trim Limited Warranties and Product Data Sheets for proprietary test results, located at TruExterior.com. Always follow local building codes and
construction best practices. See the complete Installation Guidelines for TruExterior Siding & Trim at TruExterior.com.
APPLICATION
Designed for use in non-structural applications
Suitable for ground and masonry contact
Can be used in moisture-prone areas
Installation is the same regardless of the season
TOOLS
Installed using proven woodworking tools and methods
Carbide-tipped blades and bits are recommended for
a longer tool life
FASTENING
Accepts common high-quality, exterior-grade
fasteners that are suitable for the local environment
Can be fastened close to the edge
No need for pre-drilling
No mushrooming
DURABILITY
WUI listed
No need to prime ends or field cuts
Resists rot and termite attacks*
No excessive swelling*
PAINTING
TruExterior products come pre-primed and
do require paint
No need to prime end cuts
Can be painted with any high-grade exterior paint
when following the paint manufacturer’s instructions
Dimensionally stable, promoting long-lasting paint
adhesions, even with dark colors*
Virtually no moisture cycling, paint last longer than on
wood*
Traditional exterior-grade caulks and exterior-grade
wood fillers are acceptable for filling nail holes
BEAUTY
Tighter gaps, minimal movement—it will move less
than PVC and vinyl
True look of cedar, real architectural detail
WARRANTY
20 year limited warranty
Pictured: Board-and-Batten
Page 31 of 39
5
5/8 Trim Sizes 1X Trim Sizes 5/4 Trim Sizes 2X Trim Sizes
Nominal Actual Nominal Actual Nominal Actual Nominal Actual
— — — — — — 2 x 2 1-1/2" x 1-1/2"
— — 1 x 3 3/4" x 2-1/2" 5/4 x 3 1" x 2-1/2" — —
5/8 x 4 5/8" x 3-1/2" 1 x 4 3/4" x 3-1/2" 5/4 x 4 1" x 3-1/2" 2 x 4 1-1/2" x 3-1/2"
— — 1 x 5 3/4" x 4-1/2" 5/4 x 5 1" x 4-1/2" — —
5/8 x 6 5/8" x 5-1/2" 1 x 6 3/4" x 5-1/2" 5/4 x 6 1" x 5-1/2" 2 x 6 1-1/2 x 5-1/2"
5/8 x 8 5/8" x 7-1/4” 1 x 8 3/4" x 7-1/4" 5/4 x 8 1" x 7-1/4" 2 x 8 1-1/2" x 7-1/4"
5/8 x 10 5/8" x 9-1/4" 1 x 10 3/4" x 9-1/4" 5/4 x 10 1" x 9-1/4" 2 x 10 1-1/2" x 9-1/4"
5/8 x 12 5/8” x 11-1/4” 1 x 12 3/4" x 11-1/4" 5/4 x 12 1" x 11-1/4" 2 x 12 1-1/2" x 11-1/4"
TruExterior Trim is reversible with woodgrain on one side and a
smooth finish on the reverse. Available in a 16' length.
Reversible Smooth/Woodgrain Finish
BOARD-AND-BATTEN SIDING
Whether a Modern Farmhouse design or creating accents
on a gable, board-and-batten is one of the hottest
trends in home exterior design. And it’s easy to create
the board-and-batten look using just TruExterior Trim.
TruExterior Trim comes pre-primed and does require paint.
Page 32 of 39
Page 33 of 39
Page 34 of 39
STAFF REPORT: Historic District Review Board (HRB)
404 SCOTT STREET
DATE: August 13, 2025
GENERAL INFORMATION
Applicant: Thomas Rhodes (Architect)
Site Address / Tax PIN: 404 Scott Street; R120 004 000 0809 0000
Applicant's Request: Applicant is requesting approval for the following exterior changes:
• Addition of a covered porch, with a brick walkway leading out to
the sidewalk
• New shutters, new siding, new living fence
• Existing windows and shingle roof to remain; porch roof to be a
standing seam metal roof and tie into existing asphalt shingle roof
Current Zoning: T4-NEIGHBORHOOD DISTRICT (T4-N)
Contributing/Neighborhood Noncontributing – Old Commons (ca. 1960)
Flood Zone/Base Flood Flood Zone: SX, Elevation: 9’
Existing Trees No Specimen/Landmark trees are affected by this request.
ZONING DISTRICT INFORMATION
T4-NEIGHBORHOOD DISTRICT (T4-N)
Lot Width at Setback: N/A
Minimum Lot Size: N/A
Max Lot Coverage: 70% of lot area (This percentage indicates maximum lot coverage by roofs;
total impervious coverage may be an additional 10%. Parcels may also be
subject to Section 8.3 - Stormwater)
Min. Frontage Build Out 60% min; 85% max
Front Setback 0 ft -15 ft
Side Setback Corner: 0 ft – 10 ft; Interior: 5 ft min., 0 ft if attached
Rear Setback 10 ft min; from alley: 0 ft.
Building Height: Primary Structures: 4 stories max; 3.5 stories max in & fronting Historic
District & interior lots along Allison Rd
Accessory Structures: 2 stories / 30 ft max
SURROUNDING ZONING, LAND USE AND REQUIRED BUFFERS
Adjacent Zoning Adjacent Land Uses Setbacks for Adjacent Zoning
/Buffer required if rezoned
North: T4-N 406 Scott St (Noncontributing, ca.
1940) N/A
South: T4-N 801 Craven St (Noncontributing,
ca. 2007) N/A
East: T4-N 403 Scott St (Beth Israel
Congregation – Synagogue;
contributing, ca. 1907)
N/A
West: T4-N 809 Craven St/402 Scott St
(noncontributing, ca. 1975) N/A
Page 35 of 39
2
Background: The applicant is requesting approval for a covered porch (182 sqft) located at the front of the
existing ca. 1960 1-story structure. The project consists of the covered porch with a green standing seam metal
roof, a new brick walkway leading to the sidewalk, new shutters, new siding, and a new living fence. The existing
wood windows and asphalt shingle roof are to remain. The porch’s standing seam metal roof is to tie into the
existing shingle roof. The applicant has been to one (1) HTRC Meeting on July 2nd, 2025.
Project timeline
Jan.
2025
Feb. M ar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec.
7/2:
HTRC
Meeting
8/1: HRB
Application
Submittal
8/13: HRB
Meeting
Applicant has been to the HTRC Meeting on July 2nd, 2025 – Summary of discussion points:
1. Planning and Zoning:
o Noncontributing, ca. 1960
o Zoned T4-HN
2. Building Codes:
o SX flood zone; 8’-9’ contours
o Flood ordinance 50% and 33% rule may apply
33% is based on the footprint increase
50% of the cost of construction vs assessed value
3. Staff Architects (Meadors Architecture):
o Staff is supportive of porch addition on structure, with some modi�ications
Staff recommends adding a horizontal beam on the sides of the porch, aligning with the
beam across the front of the porch.
Staff recommends adding pilasters aligning behind the porch columns
The roof appears thin – provide accurate detail
o Applicant to provide a section through the porch, as well as a typical eave and rake detail.
o Applicant to note that the living fence cannot exceed a height of 4’-0”.
o Staff is supportive of either keeping the existing painted CMU uncovered, or applying the siding
since this is a noncontributing structure. Applicant to clarify what material the siding will be. Please
note that vinyl siding is not permitted in the historic district. Cementitious siding must have a
smooth �inish.
o Provide a detail showing how the new siding will terminate at the skirtboard, as well as the
windows and doors (drawings show new casings around windows and doors).
o Applicant has noted that the porch �loor will be brick. Applicant to provide a detail of the brick and
concrete slab.
o Staff is supportive of shutter addition. Applicant to note that shutters must be operable with
operable hardware. Faux shutters are not allowed. Shutters cannot be vinyl.
Page 36 of 39
3
o Staff recommends the applicant keep the rectangular louvered vent detail (replace in-kind if
needed), rather than install a circular vent. Circular vents are not a common detail in the historic
district.
o Applicant to provide material cutsheets for the following:
Brick
Standing seam roof
Paint colors
• Siding
• Shutters
• Living fence
• Columns/porch trim
4. Historic Beaufort Foundation (HBF):
o Recommend to maintain the CMU siding
Tree Removal Proposed:
No Specimen/Landmark trees are affected by this request.
Surrounding Area:
Located in the Old Commons neighborhood, the property lies on the west side of Scott Street facing east, close to
the intersection of Scott Street and Craven Street. The property is classified as a noncontributing structure, with
the north and south properties also being noncontributing structures, and the Beth Israel Congregation Synagogue
(ca. 1907) directly across the street from the property.
Determination of adequate historic integrity for New Construction, Infill, Additions and Demolition:
As per the Beaufort Preservation Manual (Chapter 5) and the Beaufort Development Code (Section 4.7), the
compatibility of new infill construction as well as major renovations within the Beaufort Historic District is
determined in consideration with the following principles: 1. Location, 2. Design, 3. Setting, 4. Materials, 5.
Workmanship, 6. Feeling and 7. Association. See detailed staff analysis and recommendations in table below.
4.7.2 Integrity Guidelines (as per Beaufort
Development Code)
Rationale
Present
Staff Analysis of Rationale
1. Location: This is the relationship between the
property and its historical context.
YES 404 Scott Street is located within the Old
Commons neighborhood of the Historic
District. Staff believes the proposal would
not impact the relationship between the
property and its historical context within
the area.
Page 37 of 39
4
2. Design: This is the combination of elements
that create the feeling of a district or structure.
These elements include building patterns,
streetscapes, site elements, building size, mass
and scale, spatial relationships, and specific
architectural elements and details.
YES Front porches are an integral feature in
Beaufort. Along with the other design
features proposed, staff believes the
proposal will not negatively alter the
streetscape, nearby site elements, or the
spatial relationship with nearby buildings.
3. Setting: This is the physical environment of a
property and should be evaluated on its context
as well as on the historical role the property has
played and continues to play. Important features
include topography, vegetation, man-made
features, and relationships between existing
structures and their surroundings.
YES Staff believes the relationship between the
house and the historic setting of the
neighborhood are not impacted by the
proposal.
4. Materials: These are the physical elements
that make up a property or district.
YES Per the preservation manual, the proposed
materials are appropriate for the Historic
District. While staff would have preferred to
leave the CMU uncovered, hardie plank is an
acceptable siding material for a
noncontributing structure. The standing
seam metal roof for the porch is also
appropriate.
5. Workmanship: This is the physical evidence
of the crafts of a particular culture or time
period. This particularly applies to rehabilitation
projects, but for new infill projects, workmanship
of surrounding structures should be considered
and respected.
YES Staff believes the workmanship of the
existing house as well as the surrounding
structures will not be impacted by the
proposal.
6. Feeling: This is the property's expression of
the aesthetic or historic sense of a particular
period of time. This particularly applies to
rehabilitation projects, but for new infill projects,
the feeling of surrounding structures should be
considered and respected.
YES Staff believes the feeling of the existing
house as well as the surrounding structures
will not be negatively impacted by the
proposal.
7. Association: This is the direct link between an
important historic event or person and a
property.
YES N/A
Page 38 of 39
5
FINDINGS AND RECOMMENDATIONS
Staff is supportive of the following items:
1. Applicant is proposing to clad the structure with a smooth cementitious lap siding. Staff is
supportive of this siding but would also be in support of keeping the CMU exposed.
2. Staff is supportive of the proposed light fixture, and requests clarification regarding which finish
the applicant plans to select. Staff would be supportive of either the copper or oil-rubbed bronze
finish. Staff also recommends the fixture be electric.
3. Staff is supportive of the living fence design and color to match the siding.
4. Staff is supportive of the stained sapele front door.
Staff is supportive of the overall project, in that it satisfies the intent of the Beaufort Preservation Manual.
However, following aspects should be clarified before considering FINAL APPROVAL:
1. Staff recommends selecting a different color for the standing seam metal roof. Staff has concerns
that the “Patina Green” color selected by the applicant will appear too different in color next to the
existing dark gray asphalt shingle roof, even though it is a low-slope roof. Staff recommends
selecting a gray color to match the existing roof. Staff is supportive of the siding/trim/window
color, shutter color, and porch ceiling color.
2. Applicant is proposing fiberglass shutters. Staff may be supportive of fiberglass shutters since this
structure is non-contributing, but requests a sample or mockup of a shutter to better understand
the appearance of the shutter.
3. The proposed shutters at the ganged window on the front (east) façade do not appear to be wide
enough to cover the width of the windows. Staff recommends using bi-fold shutters at these
windows with a longer shutter dog to accommodate both panels.
4. Staff recommends reducing the depth of the eave at the front of the porch from 2’-0” to 1’-6” or
shorter to better match the eave depths on the existing structure.
Page 39 of 39
Source: City of Beaufort website. First collected Nov 1, 2026.