RecordWell Data

Board of Zoning and Appeals — Agenda Packet

City of Spartanburg · Spartanburg County · Boards and Commissions · meeting of May 14, 2024 · Agenda packets

Open the original document More from City of Spartanburg

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

The City of Spartanburg Board of Zoning Appeals City of Spartanburg | Board of Zoning Appeals 1 AGENDA May 14, 2024, at 5:15 P.M. Spartanburg County Council Chambers 366 N. Church Street – Spartanburg, SC 29303 ( Please Note: Items as they appear on the Docket may or may not be considered in the order as they are presented. The Chairman will announce any changes after the roll call) I. C all To Order. II. R oll Call. III. F reedom Of Information Act Compliance – Public notification of the Board of Zoning A ppeals meeting has been published, posted and mailed in compliance with the Freedom of Information Act and the Requirements of the City of Spartanburg Zoning Ordinance. IV . Approval of Agenda. V. D isposition of Meeting Minutes from the April 9, 2024, Meeting. V I. Old Business: None. V II. New Business: 1. VAR-24-002-00007: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the lot size for properties located at 1374 and 1376 Drayton Road (TMS: 7-09- 13-113.00); with a zoning designation of R-12 (General Residential District). Owner/Applicant: Fernando Geiss and Henry Partowidjojo. 2. AP P-24-002-00008: The City of Spartanburg’s Board of Zoning Appeals has received a request for an appeal to the permitted use table regarding a dog grooming business, Tails in the City, l ocated at 222 E. Blackstock Road (TMS: 6-20-12-089.00); with a zoning designation of B-1 ( Neighborhood Shopping District). Applicant: Rebekah DeHart, Tails in the City. 3. VAR-24 -002-00009: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the lot frontage for property located at 558 Hugh Street (TMS: 7-11-08-121.00); with a zoning designation of R-8 (General Residential District). Applicant: Hall Dillard, H . D illard Company, Inc. 4. VAR-24 -002-00010: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the front and rear setbacks and building coverage for property located at 128 L eague Street (TMS: 7-16-10-124.00); with a zoning designation of R-8 (General Residential District). Owner/Applicant: Angela Cardona. 5. VAR-24 -002-00011: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the front and interior side lot setback for property located at 187 Carlisle Street (TMS: 7-12-14-286.00); with a zoning designation of R-8 SFD (General Residential – Single- family District). Owner: Thomas Wooten / Applicant: Gabriel Weisser; Taylored Homes. The City of Spartanburg Board of Zoning Appeals City of Spartanburg | Board of Zoning Appeals 2 VIII. Staff Announcements: IX. Adjournment. For more information, please contact Fredalyn M. Frasier, Planning Director, at (864) 580-5012 or by email at planning@cityofspartanburg.org. BZA - Meeting Minutes - 2024-04-09 Page 1 of 7 Meet ing Minutes of the Board of Zoning Appeals Tuesday, April 9th, 2024, at 5:15 PM City Hall Council Chambers The Board of Zoning Appeals met in City Hall Council Chambers on Tuesday, April 9th, 2024, at 5:15PM with the following members in attendance Dominique Dawkins, Brian Cohen, McKay Moore, Don Bramblett and Darren Matz. Representing the Planning Department is Martin Livingston, Community Services Director, Nan Zhou, Planner II, and Oksana Holbrooks, Administrative Assistant. R oll Call: M r. Bramblett: Don Bramblett Mr. Matz: Darren Matz Ms. Moore: McKay Moore Mr. Cohen: Brian Cohen Ms. Dawkins: Dominique Dawkins Mr. Matz: The Freedom of Information Act Compliance says this. Public notification of this meeting has been published, posted, and mailed in compliance with the Freedom of Information Act and the requirements of the City of Spartanburg Zoning Ordinance. A pproval of Agenda: A motion was made by Mr. Bramblett, seconded Ms. Dawkins to approve the agenda. The motion was approved with a vote of 5-0. Mr. Bramblett: I move we approve the agenda. Ms. Dawkins: Second Mr. Matz: All in favor? Attendees: Aye. Mr. Matz: Next item is the disposition of meeting minutes from previous meeting March 12th, 2024. Anybody comments? Approval with edits to Meeting Minutes from March 12th, 2024. A motion was made by Ms. Moore seconded Ms. Dawkins the motion was approved with a vote of 5-0. Ms. Moore: I move we approve the minutes. Ms. Dawkins: Second. Mr. Matz: All in favor? Attendees: Aye. O ld Business: None BZA - Meeting Minutes - 2024-04-09 Page 2 of 7 New Business: The City of Spartanburg’s Board of Zoning Appeals has received a request for a Special Exception to open a school in the existing wing of the Eastside Baptist Church located at 1850 Fernwood Glendale Road (TMS # 7-14-02-001.01) with a zoning designation of R-15, Single Family Residential district. Owner / Applicant: Eastside Baptist Church Project Description and History The project site is an approximately 326,264.4 square foot (7.49 acres) lot located in the R -15 (Single Family Residential District) zoning designation. The project site abuts Fernwood Glendale Road to the south boundary and Sloans Grove Road to the north boundary. The project site is surrounded by R-15, Single Family Residential District, neighborhood to the west, and R-6 PDD, General Residential Plan Development District, neighborhood to the east. Eastside Baptist Church currently has a kid’s ministry and student’s ministry that provide engaging learning experiences to kids and students, equipping each student through meaningful discipleship relationship that will ensure their growth. The kid’s ministry is operated on Sundays (Sunday School at 9:30 am and Children’s Church at 10:30 am) The applicant, East Baptist Church, is proposing to open a school for kids with special needs within the existing children’s wing of the church (in the front section of the building) that will house approximately 15 to 30 children during normal school hour s, Monday through Friday from 7:am to 3:30 pm. Analysis Zoning Ordinance Consistency The project site has a zone designation of R-15, Single Family District. Section 302.1 R-15 Single Family Residential District Uses Permitted by Special Exception Section 302.1 B of the City of Spartanburg Zoning Ordinance, R-15, Single Family District, does allow uses for churches, synagogues, and other places of worship and public schools and private and parochial schools having a curriculum approximately the same as ordinarily given in public school. A Special Exception may be granted by the Board of Zoning Appeals to the usage listed in the zoning ordinance Section 302.1 B Uses Permitted by Special Exception. Special Exceptions may only be granted under use regulations for residential districts as uses permitted by special exception. The Board must utilize Section 603.53 Guidelines and determine whether a special exception should be granted, in addition to specific criteria in district regulations: a. Traffic impact; b. Vehicle and pedestrian safety; c. Potential impact of noise, lights, fumes, or obstruction of air flow on adjoining property; d. Adverse impact of proposed use on the surrounding area including the aesthetic character of the area; and e. Orientation and spacing of improvements or structures. f. Compliance with the Comprehensive Plan BZA - Meeting Minutes - 2024-04-09 Page 3 of 7 The Board may prescribe appropriate conditions and safeguards to relieve or reduce adverse impact of a special exception and to protect the character of the area. No variance may be granted by the Board in connection with the granting of a special exception. Findings 1. Traffic impact – Currently, the Eastside Baptist Church has a big parking lot with a 24 ft driveway in the front and two entrances allowing for vehicle queuing for drop off and pick up of students. The applicant indicates that the proposed school will only have 15 to 30 students with an average of 15 to 20 cars per hour Monday through Friday from 7-8 am and 3:30 pm to 4 pm. 2. Vehicle and pedestrian safely – Unfortunately, staff has not received a vehicle traffic flow plan yet. However, the applicant indicates that due to the sufficient length of the parking lot driveway, there will not be any road congestion generated along the parking lot driveway and pedest rian safety will be maintained by proposed measures that would require vehicles to be stopped and engines to be turned off when dropping off or picking up children. 3. Potential impact of noise, lights, fumes, or obstruction of air flow on adjoining property – Currently, the Church has kids’ ministry and student’s ministry services on Sundays and Wednesday. The proposed school will be in the existing children’s wing section of the church that is closer to the front of the parking lot, noises generated will not i mpact the neighborhoods on the west and east side of the Church. Staff does not anticipate fumes or obstruction of air flow on adjacent properties. 4. Adverse impact of proposed use on the surrounding area including the aesthetic character of the area; and – Staff does not anticipate any adverse impact of the proposed school on surrounding area in terms of the aesthetic character of the area. The proposed school will be open inside the existing structure. No additional portion(s) will be added onto the existin g structure. The nature and character of the area will still remain the same. 5. Orientation and spacing of improvements or structures – The proposed school is located inside the existing church building, therefore, the orientation and spacing of the church structure will not be impacted by the proposed use. 6. Compliance with the Comprehensive Plan – 2024 City of Spartanburg Comprehensive Plan lists the area as G-2 Neighborhood Controlled Growth Sector. In the Land Use and Community Character Element, it says that “……Neighborhood Controlled Growth Sectors are areas that are developed with low - to medium-density neighborhoods that should remain ‘as is’. These neighborhoods are defined by conventional suburban development patterns of primarily detached single-family houses, with a limited number of multi- family, commercial, and civic uses. There may be so me limited opportunities for infill in this Sector, which should be at a scale and character compatible with surrounding development. The proposed use of a school for kids with special needs is a civic use, and based on the number of students proposed on a daily basis, the activity is less intense. Applicant: Eastside Baptist Church Daniel Wood, 224 Thorncrest Dr. BZA - Meeting Minutes - 2024-04-09 Page 4 of 7 Public Comment: Susan Holland, 293 Lake Forest Dr. Discussion: The proposed project is well presented. A school is well needed for special needs. As long it meets all requirements pf SCDOT and criteria’s presented it should do well. A motion was made by Mr. Bramblett, seconded Mr. Cohen to approve the Special Exception with conditions the school meets SCDOT school zone requirements with traffic study with a vote by 5-0. The City of Spartanburg’s Board of Zoning Appeals has received a variance request to the lot size requirements to develop the Theodosia triplex (three-unit multifamily apartment) located at 108 Theodosia Drive (TMS: 7-15-04-058.00); with a zoning designation of R-12 (General Residential District). Owner/Applicant: Levi Kennedy. Project Description and History The project site is an approximately 21,000 Square foot lot located at 108 Theodosia Drive (TMS: 7- 15-04-058.00); with a zoning designation of R-12 (General Residential District). The site is located in a traditional single-family neighborhood with one existing non-conforming lot with two duplexes. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and Dimensional Requirements by District which requires 10,000 square feet of area for each unit developed. The current size of the property is approximately 21,000 and would only support the development of a duplex. Appeals to the Board may be taken by any person aggrieved or by any officer, department, board, or bureau of the municipality or county. Such an appeal shall be submitted no later than ten (10) days after the start of construction or within thirty (30) days after a decision by a board, commission, or bureau, or a decision of the Zoning Administrator, whichever is lesser. Such notice of an appeal, special exception, or variance shall be accompanied by a check in the amount of $150 payable to the City of Spartanburg to partially defray the cost of giving public notice of such hearing, none of which shall be refundable. The officer from whom the appeal is taken shall forthwith transmit to the Board all papers constituting the record upon which action appealed was taken from. An appeal stays all legal proceedings in furtherance of the action appeal from, unless the officer from whom the appeal is taken certifies to the Board, after the notice of appeal shall have been filed with him, that by reason of facts stated in the certificate a stay would, in his opinion, cause imminent peril to life and property. In such case, proceedings shall not be stayed otherwise than by a restraining order which may be granted by this Board or by a court of record on application, on notice to the officer from whom the appeal is taken, and on due cause shown. To hear and decide appeals where it is alleged there is error in an order, requirement, decision, or determination made by an administrative official in the enforcement of the zoning ordinance. forthwith transmit to the Board all papers constituting the record upon which action appealed was taken from. An appeal stays all legal proceedings in furtherance of the action appeal from, unless the officer from whom the appeal is taken certifies to the Board, after the notice of appeal shall have been filed with him, that by reason of facts stated in the certificate a stay would, in his opinion, cause imminent peril to life and property. In such case, proceedings shall not be stayed otherwise than by a restraining order which may be granted by this Board or by a court of record on application, on notice to the officer from whom the appeal is taken, and on due cause shown. To hear and decide appeals where it is alleged there is error in an order, requirement, decision, or determination made by an administrative official in the enforcement of the zoning ordinance. BZA - Meeting Minutes - 2024-04-09 Page 5 of 7 Analysis Zoning Ordinance Consistency The project site is an approximately 21,000 Square foot lot located at 108 Theodosia Drive (TMS: 7- 15-04-058.00); with a zoning designation of R-12 (General Residential District). The site is located in a traditional single-family neighborhood with one existing non-conforming lot with two duplexes. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and Dimensional Requirements by District which requires 10,000 square feet of area for each unit developed. The current size of the property is approximately 21,000 square feet and would only support the development of a duplex. Based on Section 603.4(3) Variances, the Board has the authority to permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; The Board must utilize Section 603.3(A)(2) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for a Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. A Variance may be granted in an individual case of unnecessary hardship if the Board makes and explains in writing the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – No. There are no extraordinary and exceptional conditions pertaining to this particular piece of property that would allow it to be developed as a tri-plex. The current size of the property would allow it to be developed as a duplex. The site is located in a traditional single-family neighborhood with one existing non-conforming lot with two duplexes. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and Dimensional Requirements by District which requires 10,000 square feet of area for each unit developed. The current size of the property is approximately 21,000 square feet and would only support the development of a duplex. A significant amount of the property is in a flood plain and cannot be developed – like other properties in the vicinity. 2. These conditions do not generally apply to other properties in the vicinity – BZA - Meeting Minutes - 2024-04-09 Page 6 of 7 No. The conditions at this property are similar to the conditions of other properties in the vicinity. The current size of the property is approximately 21,000 square feet and would only support the development of a duplex. A significant amount of the property is in a flood plain and cannot be developed – like other properties in the vicinity. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – No. The application of the ordinance does not restrict the use of the property. The property can be used as single-family or duplex housing. The property size is not large enough to be converted to a tri-plex apartment. The development of a tri -plex apartm ent would not be consistent with the character of the surrounding neighborhood. 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Yes. The authorization of a Variance will create an existing non-conforming use in a traditionally single-family neighborhood. There is already an existing non-conforming use with two duplexes on one lot in the neighborhood. The property size is not large enough to be converted to a tri-plex apartment. The development of a tri-plex apartment would not be consistent with the characte r of t he surrounding neighborhood. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare– N o. Approval of this variance would create a non-conforming use. The current size of the property would allow it to be developed as a duplex. The site is located in a traditional single-family neighborhood with one existing non-conforming lot with two duplexes. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and Dimensional Requirements by District which requires 10,000 square feet of lot area for each unit developed. The current size of the property is approximately 21,000 square feet and would only support the development at maximum a duplex. A significant amount of the property is in a fl ood p lain and cannot be developed – like other properties in the vicinity. S ummary and Recommendation The proposed request does not meet all the required Findings for approval of the Variance. Staff recommends denial of the request based on the Findings listed above. In e xercising its powers, the Board of Zoning Appeals may, in conformity with the provisions of Section 603, reverse or affirm, wholly or in part, or may modify the order, requirements, decision, or determination, and to that end, has all the powers of the officer from whom the appeal is taken and may issue or direct the issuance of a permit. The board, in the execution of the duties specified in this chapter, may subpoena witnesses and in case of contempt may certify this fact to the circuit court having jurisdiction. A ll final decisions and orders of the board must be in writing and be permanently filed in the office of the board as a public record. All findings of fact and conclusions of the law must be separately stated in final decisions or orders of the board which must be delivered to parties of interest. A pplicant: Levi Kennedy. BZA - Meeting Minutes - 2024-04-09 Page 7 of 7 Public Comment: McDonald Pearson, 141 Chester St. D iscussion: The proposed project does not meet all requirements for approval. A motion was made by Ms. Moore, seconded Mr. Bramblett the Variance was denied with a vote of 2-3. Staff announcements. A new Planning Director will be joining Planning Department team Fredalyn M. Frasier April 22, 2024. Board members need to do renewals to be able to serve another term on the board T he meeting was adjourned at 6:39 PM. ______________________________ Darren Matz, Chairman Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org TO: The Board of Zoning Appeals RE: VAR-24-002-00007: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the lot size for properties located at 1374 and 1376 Drayton Road (TMS: 7-09- 13-113.00); with a zoning designation of R -12 (General Residential District). Owner/Applicant: Fernando Geiss and Henry Partowidjojo. Date: May 14, 2024 Project Description and History The project site is an approximately 23,000 foot lot located at 1374 and 1376 Drayton Road (TMS: 7-09- 13-113.00); with a zoning designation of R -12 (General Residential District) . The site is located in a traditional single-family neighborhood and surrounded by other single -family lots . The applicant is requesting a variance to the lot size requirements which is less than 12,000 square feet for each of the property. The applicant submitted a survey for approval, but staff noted that the survey did not meet the lot size requirement. Staff also requested a survey of the second lot to determine if any other variances would be required. The applicant provided a survey that indicated that the lot frontage and the lot size also did not mee the zoning ordinance. Variances from the regulations of this Ordinance shall be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and may be granted only in the following instances and in no others: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; (*) 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; 4. To permit the same off -street parking facility to qualify as required facilities for two or more units, provided that substantial use of such facility by each use does not take place at approximately the same hours of the same days of the week; 5. To reduce the applicable off -street parking or loading facilities required by not more than one (1) parking space or loading space, or twenty -five percent (25%) of the required facilities, whichever number is greater; 6. To allow for the deferment of required parking facilities for a reasonable period of time, such period of time to be specified in the variance; 7. To increase by not more than forty percent (40%) the maximum distance that required parking spaces are permitted to be located from the use served; 8. To permit the height of a fence in the required rear, side and corner side yard to exceed the maximum height allowed by this Ordinance up to eight (8) feet when property is exposed to exceptional nuisances of traffic, dust, noise, glare, and vandalism; and (*) 9. To reduce the setback requirement for portable signs provided that no variance shall be granted to permit such signs within the triangular area formed by the right-of-way lines of intersecting streets (or a street and a driveway), and a line joining points on the right-of-way lines twenty-five (25) feet from the point of their intersection. If the property in question has no defined driveway to its parking area Page 2 of 13 the Board shall satisfy itself that the proposed location of the portable sign will not interfere with traffic by blocking reasonable sight lines for streets, sidewalks and driveways before any variance is granted. The application for such variance shall be accompanied by a scaled drawing showing all information relevant to the variance request. (**) Analysis Zoning Ordinance Consistency The project site is an approximately 23,000 foot lot located at 1374 and 1376 Drayton Road (TMS: 7-09- 13-113.00); with a zoning designation of R -12 (General Residential District). The site is located in a traditional single -family neighborhood and surrounded by other single -family lots. The applicant is requesting a variance to the lot size requirements which is less than 12,000 square feet for each of the property. The applicant submitted a survey for approval, but staff noted that the survey did not meet the lot size requirement. Staff also requested a survey of the second lot to determine if any other variances would be required. The applicant provided a survey that indicated that the lot frontage and the lot size also did not mee the zoning ordinance. Based on Section 603.4(1-3) Variances, the Board has the authority to permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; The Board must utilize Section 603.4(1-3) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for a Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. A Variance may be granted in an individual case of unnecessary hardship if the Board makes and explains in writi ng the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – No. There are no extraordinary and exceptional conditions pertaining to the particular piece of property. The project site is an approximately 23,000 foot lot located at 1374 and 1376 Drayton Road (TMS: 7-09-13-113.00); with a zoning designation of R-12 (General Residential District). The site is located in a traditional single -family neighborhood and surrounded by other single -family lots. The applicant is requesting a variance to the lot size requirements which is less than 12,000 square feet for Page 3 of 13 each of the properties. The site is located in a traditional single-family neighborhood and surrounded by other single-family lots. The applicant is requesting a variance to the lot size requirements which is less than 12,000 square feet. All documentation provided by the applica nt indicates that the lots were originally separate lots and combined by a survey. Currently, the lot in its present condition is considered existing non- conforming to the zoning ordinance . If the variance is approved, the lots would meet the zoning ordinance requirements. A majority of the lots in the area have 80 feet frontage, but may not meet the lot size requirements or have lot frontage less than 80 feet. 2. These conditions do not generally apply to other properties in the vicinity – Yes. There are several lots in the area that have similar conditions. The three lots on Drayton R oad which are less than 12,000 feet in size. The applicant provided a survey for both lots which indicate lot sizes less than 12,000 feet and one lot frontage less than 80 feet. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – No. The application of the ordinance would not unreasonably restrict the utilization of the property. The property can still be used in its current condition but would be nonconforming to the zoning ordinance. 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Yes. The authorization of a variance will not be of substantial detriment to the adjacent property or to the public good, and authorization of the district will not be harmed by the granting of the variance. Several lots in the area do not meet the lot size requirement and frontage measurements. Approval of the variance to reduce the lot size and the frontage would also meet the 80% rule required in Section 603.4(3) of the Zoning Ordinance. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare– Yes. Staff recommends, if approved, that a survey indicating all setbacks be required to be submitted for review and approval for both lots. Approval of this variance would eliminate the non-conforming condition. The application of the variance would create two single-family lots. The variance from the regulations of the zoning can be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and can be granted in the following instances: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; (*) 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; Summary and Recommendation The proposed request meet s all the required Findings for approval of the Variance , Staff recommends approval of the variance to the lot size and lot frontage requirements to create two single-family lots. In exercising its powers, the Board of Zoning Appeals may, in conformity with the provisions of Section 603, reverse or affirm, wholly or in part, or may modify the order, requirements, decision, or Page 4 of 13 determination, and to that end, has all the powers of the officer from whom the appeal is taken and may issue or direct the issuance of a permit. The board, in the execution of the duties specified in this chapter, may subpoena witnesses and in case of contempt may certify this fact to the circuit court having jurisdiction. A ll final decisions and orders of the board must be in writing and be permanently filed in the office of the board as a public record. All findings of fact and conclusions of the law must be separately stated in final decisions or orders of the board which must be delivered to parties of interest. S ubmitted by: M artin L. Livingston, Jr., AICP, CPM Community Development Director A ttachments: Conditions of Approval Application Photos Page 5 of 13 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY LOCATED AT: 1374 and 1376 Drayton Road (TMS: 7-09-13-113.00) 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All setbacks excluding the interior side yard setback shall meet the setback requirements in the City of Spartanburg Zoning Ordinance, where the maximum building coverage is not applicable, front yard setback is 30 feet, rear setback is 30 feet, the interior side setback is 8 feet, and the street side setback is 15 feet. 3. The use shall meet the standards and shall be developed within the limits established by Chapter 501.10 of the Spartanburg Municipal code as to the emission of noise, odor, smoke, dust, vibration, waste, fumes or any public nuisance arising or occurring incidental to its establishment or operation. 4. The applicant shall be responsible for the completeness and accuracy of all forms and supporting material submitted in connection with any application. Any errors or discrepancies found therein may result in the revocation if any approval or permits issues in connection therewith. 5. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. All aspects of construction must be completed prior to use. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 6. All requirements of the Building, Fire, Water and Streets and Stormwater Departments shall be completed prior to building occupancy permit issuance and continuously maintained thereafter. 7. Site Pre-construction meeting with the City of Spartanburg Storm Water Manager, Jay Squires, is required prior to site disturbance. Building pre -construction meeting with City of Spartanburg Building Official, Buddy Bush, required prior to vertical construction. 8. A survey is required for both lots to determine setbacks and to determine compliance with the zoning ordinance. Page 6 of 13 SITE MAP Page 7 of 13 ZONING MAP Page 8 of 13 Table 401 – (A) Table of Area Dimensional Requirements Page 9 of 13 Page 10 of 13 Page 11 of 13 Page 12 of 13 Site Photos Page 13 of 13 Site Photos N.T.S. ~-(J ---~ ~- LEGEND: 1.0. -IRON OLD I.N. -IRON NEW .,,~ HII.LCREST SHOPPING CENTER ( ) -COPIED MEASUREMENT • ~-, LOCATION MAP POINT IN 2411 1.0.1/2• 1.0.3/a•R~BAR __ O_VE_RHEAD POWER LINE ~~R=O:D::t_:_:_:_:_=AT~f_-·:;;5_4=-=-~~-.;:-_ _:x_::~~ (79.94') N 64"25'49"W-IIIMl=--- CATAWBA ~E_E __ x _ ADJ0INER'S CHAIN LINK FENCE t -;;: .. co 0) 0 co .. ·I"') 0) I"') "q". ..... U) N (/) -x ..J i C!) M.H. (PAWD .2!!ff) 80.00' BLOCK ,.G,, 0 0.275 AC. 11,988.48 S.F . w :: .. 0 0 I!) co .. . N 0) I"') "q" in ..-N a) 0 (80.0') 0 SANITARY SEWER LINE ---30' BUILDING LINE 1.0.3/8" 80.06' 1.0.1 /2" NAIL OLD , 1.0.1 /2" -S 64"28' 18"E ROD AT 58.17' 80.01 ROD ( ') REBAR o---_ ___:.;,~--E~~~.ei------~R'~~;;~~~--=;t~=~-~=:..-~_~_7=9=.6=8===RO=A~D~R;/;W== ~/f -s 64"29'38~'E POLE f¤.Rl-\~ gc, .,- CURB ~G Q'\ A,,0'\ .,-'\ A-- " 0-ji, 7-09-1.M,11' oroyton Rood NOTES: lw I~ ..J ffi a. :::c 0:: IJ.l I~ I POLE CURB 1-THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY THE SURVEYOR. 2-THE SURVEY SHOWN HEREON REFLECTS THE RECORDED REFERENCES AS NOTED. 3-AREA SUBJECT TO ALL RIGHTS OF WAY AND EASEMENTS OF RECORD OR NOT OF RECORD. 4-ALL UNDERGROUND UTILITIES ARE NOT SHOWN AND THEIR LOCATIONS ARE UNKNOWN TO ME. SURVEY FOR: Alberto Luie Rabuske BEING LOT NO. 9, BLOCK "G" OF HILLVIEW SUBDMSION, PLAT RECORDED IN PLAT BOOK 42 AT PAGES 103-105. ALSO SEE PLAT BOOK 109 AT PAGE 816 & DEED BOOK 122-T AT PAGE 358. ···---···--·· ···---··--CC"AI N.T.S. LOCATION MAP @ {80.00') SEE PLAT FOR ALBERTO LUIZ RABUSKE BY THIS OFFICE DATED MAY 5, 2024 0 SANITARY SEWER LINE 35' SETBACK LINE ~ t :!i :..i. i ,, a. 64AO' ~1-,. (80.01') ~gf2" POL£ !ft S 64'28'58"E \~. - ----' ROAD R/W WALK coNCREfE Drayton LEGEND: 1.0. - IRON OLD 1.N. - IRON NEW ( ) - COPIED MEASUREMENT 0 MAG NAIL P/L AT BACK OLD LOT N~--~ - --~UNE 15.28' s 68°24' 45"E CURB Road CURB Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org TO: The Board Zoning Appeals RE: APP-24-00200008 The City of Spartanburg’s Board of Zoning Appeals has received an Appeal to the permitted use table regarding a dog grooming business, Tails in the City, located at 222 E. Blackstock Rd. (TMS # 6-20-12- 089.00) to be allowed in the B- 1, Neighborhood Shopping District. Applicant: Rebekah Dehart, Tails in the City. D ate: May 6th, 2024 Project Description and History In earlier 2024, a building inspector found out that a dog grooming business was open without a Certificate of Occupancy and did not have an exhaust system installed inside the business. Later, when the business owner applied for the Certificate of Occupancy, planning staff became aware that t he business use, pet grooming, is not allowed per the current City of Spartanburg Zoning Ordinance. Upon review of the City’s Zoning Ordinance, staff noticed that pet grooming services are not stand alone uses but are recognized under Animal Kennel & Veterinary Clinic. Page 2 of 13 The proposed business is located at a strip mall shopping center that has a zoning designation of B -1, Neighborhood Shopping District. Based on the City of Spartanburg Zoning Ordinance Section 301 to 303: District Use Regulations and Section 303.6 Table of Permitted Uses , grooming is a service that will be allowed under Animal Kennel . However, Animal Kennel is not permitted use for properties under B -1, Neighborhood Shopping District zoning. Veterinary Clinic is allowed for businesses with B -1 zoning designation, but prohibiting clipping, grooming, and retail sales of pet products and accessories. The applicant is seeking an appeal to allow her business of a dog grooming business to stay open at 222 E. Blackstock Rd. Ste E. An appeal stays all legal proceedings in furtherance of the action appeal from, unless the officer from whom the appeal is taken certified to the Board, after the notice of appeal shall have been filed with him, that by reason of facts states in the certificate a stay would, in his opinion, cause imminent peril to life and property. Analysis Zoning Ordinance Consistency The Board must utilize Section 603.3(A)(2) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. An appeal may be granted in an individual case of unnecessary hardship if the Board makes and explains in writing the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – Staff does not recognize any extraordinary and exceptional conditions pertaining to this particular piece of property. This dog grooming business sits in a small strip mall center surrounded by offices and retail stores. Given the proposed use, staff confirmed with the Building Official that an exhaust ventilation system will be required to install upon approval of the request. 2. These conditions do not generally apply to other properties in the vicinity – There are no other pet grooming businesses in the immediate vicinity, other than a PetSmart located a few blocks away on E. Blackstock Rd. Both PetSmart and Petco, on E. Main St. are currently sitting on lands with a zoning designation of B-1, Neighborhood Shopping District. Both PetSmart and Petco are mainly retail stores selling pet products, with dog grooming services provided by request or appointment only. Neither of them is specializing in pet grooming services only. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – Per the current City of Spartanburg Zoning Ordinance, animal kennel, which allows for a pet grooming business, is NOT allowed under B-1, Neighborhood Shopping District. While veterinary clinic, which Page 3 of 13 DOES NOT allow pet grooming business, is allowed under B -1, Neighborhood Shopping District. Therefore, a pet grooming business is not allowed either because of the current zoning designation restrictions or because of the service. 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Staff do not believe the authorization of a dog grooming business at this strip mall center will cause substantial detriment or harm to the general public good or adjacent property. The character of this strip mall shopping center will still remain as retail stores, he alth care center/offices, and insurance company. Staff do not see issues about keeping the pet grooming business at the strip shopping center since it does not pose adverse impact to the surrounding businesses. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare– In the event that the Board finds that the findings can be met, and the project approved, conditions of approval are attached to this report. In exercising the power, the Board of Appeals may, in conformity with the provisions of this chapter, reverse or affirm, wholly or in part, or may modify the order, requirements, decision, or determination, and to that end, has all the powers of the officer from whom the appeal is taken and may issue or direct the issuance of a permit. S ubmitted by: Nan Zhou, AICP City Planner II City of Spartanburg Planning Department Attachments: Conditions of Approval Application Photos Page 4 of 13 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY LOCATED AT: 222 Blackstock Road (TMS # 6-20-12-089.00) 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. The use shall meet the standards and shall be developed within the limits established by Chapter 501.10 of the Spartanburg Municipal code as to the emission of noise, odor, smoke, dust, vibration, waste, fumes or any public nuisance arising or occurring incidental to its establishment or operation. 3. The applicant shall be responsible for the completeness and accuracy of all forms and supporting material submitted in connection with any application. Any errors or discrepancies found therein may result in the revocation if any approval or permits issues in connection therewith. 4. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. All aspects of construction must be completed prior to use. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 5. All requirements of the Building, Fire, Water and Streets and Stormwater Departments shall be completed prior to building occupancy permit issuance and continuously maintained thereafter. 6. An exhaust ventilation system shall be at place upon approval and a valid City Business Li cense shall be renewed for the proposed use. Page 5 of 13 SITE MAP – 222 E. Blackstock Road Page 6 of 13 ZONING MAP – 128 League Street Page 7 of 13 Site Photos – Store Front Page 8 of 13 Site Photos – Strip Mall Center Page 9 of 13 Site Photos – Property to the Left Side of the Project Site Page 10 of 13 Site Photos – Property to the Right Side of the Project Page 11 of 13 Site Photos – Property Across from the Project Site Page 12 of 13 Site Photos – Property Across from the Project Site Page 13 of 13 Site Photos – Properties Across from the Project Site Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org TO: The Board of Zoning Appeals RE: VAR-24-002-00009: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the lot frontage for property located at 558 Hugh Street (TMS: 7-11-08-121.00); with a zoning designation of R-8 (General Residential District). Applicant: Hall Dillard, H. Dillard Company, Inc. Date: May 14, 2024 Project Description and History The project site is an approximately 18,000 Square foot lot located at 558 Hugh Street (TMS: 7- 11-08- 121.00); with a zoning designation of R-8 (General Residential District). The site is located in a traditional single-family neighborhood with a vacant lot that was sold at the Forfeited Land Commission which is the current applicant – a contract for sale is included in the application. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and Dimensional Requirements by District which requires 8,000 square feet of lot area for a single -family property. The current size of the property is approximately 18,000 square feet would allow two lots to be developed for single-family housing. The zoning ordinance also requires a 60 feet minimum lot frontage. The lot frontage is 106 feet and would not allow for two 60 feet lot frontage. The applicant is proposing to split the lots with 8,773 square feet and 8,597 square feet each and 52.96 feet of frontage for each lot. Variances from the regulations of this Ordinance shall be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and may be granted only in the following instances and in no others: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; (*) 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; 4. To permit the same off -street parking facility to qualify as required facilities for two or more units, provided that substantial use of such facility by each use does not take place at approximately the same hours of the same days of the week; 5. To reduce the applicable off -street parking or loading facilities required by not more than one (1) parking space or loading space, or twenty -five percent (25%) of the required facilities, whichever number is greater; 6. To allow for the deferment of required parking facilities for a reasonable period of time, such period of time to be specified in the variance; 7. To increase by not more than forty percent (40%) the maximum distance that required parking spaces are permitted to be located from the use served; 8. To permit the height of a fence in the required rear, side and corner side yard to exceed the maximum height allowed by this Ordinance up to eight (8) feet when property is exposed to exceptional nuisances of traffic, dust, noise, glare, and vandalism; and (*) 9. To reduce the setback requirement for portable signs provided that no variance shall be granted to permit such signs within the triangular area formed by the right-of-way lines of intersecting streets (or Page 2 of 13 a street and a driveway), and a line joining points on the right-of-way lines twenty-five (25) feet from the point of their intersection. If the property in question has no defined driveway to its parking area the Board shall satisfy itself that the proposed location of the portable sign will not interfere with traffic by blocking reasonable sight lines for streets, sidewalks and driveways before any variance is granted. The application for such variance shall be accompanied by a scaled drawing showing all information relevant to the variance request. (**) Analysis Zoning Ordinance Consistency The project site is an approximately 18,000 Square foot lot located at 558 Hugh Street (TMS: 7- 11-08- 121.00); with a zoning designation of R-8 (General Residential District). The site is located in a traditional single-family neighborhood with a vacant lot that was sold at the Forfeited Land Commission which is the current applicant – a contract for sale is included in the application. The applicant is seeking a variance to the requirements in the zoning ordinance related to Table 401(A) Table of Area and D imensional Requirements by District which requires 8,000 square feet of lot area for a single -family property. The current size of the property is approximately 18,000 square feet would allow two lots to be developed for single-family housing. The zoning ordinance also requires a 60 feet minimum lot frontage. The lot frontage is 106 feet and would not allow for two 60 feet lot frontage. The applicant is proposing to split the lots with 8,773 square feet and 8,597 square feet each and 52.96 feet of frontage for each lot. Based on Section 603.4(1-3) Variances, the Board has the authority to permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; The Board must utilize Section 603.4( 1-3) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for a Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. A Variance may be granted in an individual case of unnecessary hardship if the Board makes and explains in writi ng the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Page 3 of 13 Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – No. There are extraordinary and exceptional conditions pertaining tothe particular piece of property. The adjacent lot at 566 Hugh Street has a lot frontage of only 52. 8 feet. Many of other lots in the area meet or exceed the lot frontage requirements. 2. These conditions do not generally apply to other properties in the vicinity – Yes. There are several lots in the area have similar conditions. The most adjacent lot is less than 60 feet wide. Several of the lots in the area are vacant and may be considered lots of record prior to the establishment of the zoning ordinance. Lots on adjacent streets meet the zoning ordinance requirements. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – No. The application of the ordinance would not unreasonably restrict the utilization of the property. The property can be developed for duplexes or one single-family structure. The applicant is proposing to split the lot and build two single -family structures for sale. The lot frontage would meet Section 603.4(1-3) requirements and meet the 80% requirements and would be consistent with the ordinance. 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Yes. The authorization of a variance will not be of substantial detriment to the adjacent property or to the public good, and authorization of the district will not be harmed by the granting of the variance. Several lots in the area do not meet the frontage requirements but meet the lot size requirements. Approval of the reduced lot frontage would also meet the 80% rule required in Section 603.4(3) of the Zoning Ordinance. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surroundin g area or to promote the public health, safety, or general welfare– No. No additional conditions of approval would be required. Approval of this variance would not create a non-conforming use. The application of the variance would create two single-family lots that can be developed for housing. The variance from the regulations of the zoning can be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and can be granted in the following instances: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; (*) 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; Summary and Recommendation The proposed request meet s all the required Findings for approval of the Variance. Staff recommends approval of the request based on the Findings listed above. Page 4 of 13 In exercising its powers, the Board of Zoning Appeals may, in conformity with the provisions of Section 603, reverse or affirm, wholly or in part, or may modify the order, requirements, decision, or determination, and to that end, has all the powers of the officer from whom the appeal is taken and may issue or direct the issuance of a permit. The board, in the execution of the duties specified in this chapter, may subpoena witnesses and in case of contempt may certify this fact to the circuit court having jurisdiction. A ll final decisions and orders of the board must be in writing and be permanently filed in the office of the board as a public record. All findings of fact and conclusions of the law must be separately stated in final decisions or orders of the board which must be delivered to parties of interest. S ubmitted by: M artin L. Livingston, Jr., AICP, CPM Community Development Director A ttachments: Conditions of Approval Application Photos Page 5 of 13 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY LOCATED AT: 558 Hugh Street (TMS: 7-11-08-121.00) 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All setbacks excluding the interior side yard setback shall meet the setback requirements in the City of Spartanburg Zoning Ordinance, where the maximum building coverage is not applicable, front yard setback is 30 feet, rear setback is 30 feet, the interior side setback is 8 feet, and the street side setback is 15 feet. 3. The use shall meet the standards and shall be developed within the limits established by Chapter 501.10 of the Spartanburg Municipal code as to the emission of noise, odor, smoke, dust, vibration, waste, fumes or any public nuisance arising or occurring incidental to its establishment or operation. 4. The applicant shall be responsible for the completeness and accuracy of all forms and supporting material submitted in connection with any application. Any errors or discrepancies found therein may result in the revocation if any approval or permits issues in connection therewith. 5. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. All aspects of construction must be completed prior to use. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 6. All requirements of the Building, Fire, Water and Streets and Stormwater Departments shall be completed prior to building occupancy permit issuance and continuously maintained thereafter. 7. Site Pre-construction meeting with the City of Spartanburg Storm Water Manager, Jay Squires, is required prior to site disturbance. Building pre -construction meeting with City of Spartanburg Building Official, Buddy Bush, required prior to vertical construction. Page 6 of 13 SITE MAP Page 7 of 13 ZONING MAP Page 8 of 13 Table 401 – (A) Table of Area Dimensional Requirements Page 9 of 13 Page 10 of 13 Page 11 of 13 Page 12 of 13 Site Photos Page 13 of 13 Site Photos City of SPARTANBURG south caratina What are the extraordinary and/ or exceptional conditions that apply to your parcel? The address has a square footage of 17,370 which is within the needed square footage to split the lot into two. With such a large piece of property we believe it would not be beneficial to the community to build just one home when the footprint of two 30x44 homes can fit the lot while meeting all required setbacks. How do these conditions differentiate your parcel from those in the immediate vicinity? Upon our observation of the general community, it appears that not all single family homes are on lots with at least 60 ft of frontage. Many lots have anywhere from 40-50 ft. 773 Saxon Ave is a property in very close proximity that we purchased recently and has only 55.21' of road frontage. ·with 105 sq ft of frontage we would be well within the road frontage for many of the single family .homes in the surrounding communities. Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org TO: The Board Zoning Appeals RE: VAR-24-00200010 The City of Spartanburg’s Board of Zoning Appeals has received a Variance request to the front and rear setbacks and building coverage for property located at 128 League St. (TMS 7 -16-10-124.00); with a zoning designation of R -8, General Residential District. Owner/Applicant: Angela Cardona. Date: May 6th, 2024 Project Description and History The project site is an approximately 5,445 square foot (0.125 acre) vacant lot with a zoning designation of R-8, General Residential District. The project site abuts League Street to the north boundary. The surrounding properties of the project site are all zoned for R-8, General Residential District. The applicant is proposing to build a single- family house on the lot that is closer to the front and rear setback requirements without reducing the footprint of the proposed house plan. Properties to the left and right side of the project site are existing non-conforming houses that were built prior to the adoption of City of Spartanburg Zoning Ordinance. Therefore, for the applicant to build a house that is consistent with other houses along League Street, the applicant is requesting a variance of reducing the front setback from 30 ft to 20 ft, and the rear setback from 30 ft to 20 ft. Analysis Page 2 of 14 Zoning Ordinance Consistency The project site has a zone designation of R-8, General Residential District. Section 302.3 R-8 General Residential District Uses Permitted by Right of the City of Spartanburg Zoning Ordinance, R-8, General Residential District, does allow Single Family dwellings. A Variance may be granted by the Board of Zoning Appeals to the minimum setback standards required in the Ordinance. Variances may only be granted in the instances listed in Section 603.4. Section 603.4 lists nine instances from which the Board may grant a Variance. Of these nine, one is applicable to this request: Section 603.4 (2): To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official. The Board must utilize Section 603.3(A)(2) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. A Variance may be granted in an individual case of unnecessary hardship if the Board makes and explains in writing the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – Staff do not recognize any extraordinary and exceptional conditions that would prevent the proposed single-family house from meeting the current front and rear setback requirements. The topography of the lot is relatively flat, and there is no natural obstacles preventing the owner from meeting the current setback requirements for R -8 zoning designation. Property to the east side of the project site is an existing non-conforming house that was built prior to the current Zoning Ordinance (The house was demolished before but left the foundation on the site. The contractor is renovating the house now). 2. These conditions do not generally apply to other properties in the vicinity – The adjacent lots of the project site are already built with single -family houses. The lots across from the street are currently vacant. The property to the east side of the project site is an existing non- conforming house and the house to the west side of the project site me ets the front and rear setback requirements. The other two vacant lots along League Street (132 & 134 League Street) need to meet the current zoning setback requirements when houses are proposed to be built on those lots. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – By granting the reduction of the front and rear setback from 30 ft to 20 ft, it will allow the applicant to build a single- family house that is approximately consistent in size with other lots in immediate surroundings. Otherwise, the project cannot be built as proposed in terms of keeping the same footprint square footage. Page 3 of 14 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Staff do not recognize any detriment or harm that will be caused to the general public. The character of the district will remain as residential neighborhoods. However, staff do not see the hardships of the lot where the current setback requirements cannot be met. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare– In the event the Board finds that the Variance finding can be met and the project approved, conditions of approval are attached to this report. The Board may choose to approve or amend them based on the outcome of this proposal. S ummary and Recommendation Based on the above Findings, S taff do NOT recommend approval of this request since no hardships or exceptional circumstances pertaining to the lot exist. S ubmitted by: Nan Zhou, AICP City Planner II City of Spartanburg Planning Department Attachments: Conditions of Approval Application Photos Page 4 of 14 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY LOCATED AT: 128 League Street (TMS # 7-16-10-124.00) 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All setbacks excluding the street side yard setback shall meet the setback requirements in the City of Spartanburg Zoning Ordinance, where the maximum building coverage is 40%, front yard setback is 30 feet (approved to be reduced to 20 ft), rear setback is 30 feet (approved to be reduced to 20 ft) , and the interior side setback is 8 feet from the property line. 3. The use shall meet the standards and shall be developed within the limits established by Chapter 501.10 of the Spartanburg Municipal code as t o the emission of noise, odor, smoke, dust, vibration, waste, fumes or any public nuisance arising or occurring incidental to its establishment or operation. 4. The applicant shall be responsible for the completeness and accuracy of all forms and supporting material submitted in connection with any application. Any errors or discrepancies found therein may result in the revocation if any approval or permits issues in connection therewith. 5. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. All aspects of construction must be completed prior to use. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 6. All requirements of the Building, Fire, Water and Streets and Stormwater Departments shall be completed prior to building occupancy permit issuance and continuously maintained thereafter. 7. Site Pre-construction meeting with the City of Spartanburg Storm Water Manager, Jay Squires, is required prior to site disturbance. Building pre -construction meeting with City of Spartanburg Building Official, Buddy Bush, required prior to vertical construction. Page 5 of 14 SITE MAP – 128 League Street Page 6 of 14 ZONING MAP – 128 League Street Page 7 of 14 Site Photos – Front Page 8 of 14 Site Photos – Property to the Left Side of the Project Site Page 9 of 14 Site Photos – Property to the Right Side of the Project Site Page 10 of 14 Site Photos – Vacant Lot Across from the Project Site Page 11 of 14 Site Photos – Vacant Lot Across from the Project Site (Another View) Page 12 of 14 Site Photos – Properties to the Right Side of the Project Site Page 13 of 14 Site Photos – Street View of League Street Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org Staff Use Only / Received by: _____________________ Date Received: _________________ Time: ____________ Permit Number: ________________________ General Application Name of Development: ______________________________________________________________________________ Street Address: ____________________________________________________________________________________ Zoning District: ________________ Overlay: ______________ Tax Map Number: ______________________ Owner: _________________________________________ Phone: __________________________ Address: ________________________________________ Email: _____________________________ City: _____________________________ State: __________________________ Zip: _________________ Applicant: _______________________________________ Phone: ____________________________ Address: ________________________________________ Email: _____________________________ City: _____________________________ State: __________________________ Zip: _________________ Agent: _______________________________________ Phone: ____________________________ Address: ________________________________________ Email: _____________________________ City: _____________________________ State: __________________________ Zip: _________________ Please select the activity requested / also, please attach the required Supplemental Form: Annexations Planned Development Districts (PDD) Special Exceptions Zoning - Conditional Use Zoning - Appeals Zoning - Variance Zoning - Map Amendment Fees and Payments can be made using the Permit Number and the City of Spartanburg Payment Portal. To the best of my knowledge, the information on this application and all additional documentation is true, factual and complete. I hereby agree to abide by all conditions of any approvals granted by the City of Spartanburg. I understand that such conditions shall apply to the subject property only and are a right or obligation transferable by sale. I hereby authorize the staff of the Planning Department to inspect the premises of the above-described property. Applicant / Owner Signature: __________________________ Date: _________________________ Planning Department PO Box 1749 • Spartanburg, SC 29304 • phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org Staff Use Only / Received by: _____________________ Date Received: _________________ Time: ____________ Permit Number: ________________________ ZONING VARIANCE SUPPLEMENTAL APPLICATION FORM Name of Development: _________________________________________________________________ Location of Development: ______________________________________________________________ Section Number(s) of the Ordinance from which a Variance(s) is requested: _____________________________________________________________________________________ Describe completely and specifically the requested Variance: _____________________________________________________________________________________ Explain briefly why the Variance is requested: _____________________________________________________________________________________ ALL OF THE FOLLOWING ITEMS MUST BE ATTACHED for this application to be complete. __ A typed narrative that explains How and Why the requested Variance meets All of the criteria of the Zoning Ordinance Section 603.3 (A) (2), (see attached copy). Criteria for Approval of Variances; and __ Notarized written certification, signed by the owner(s) of record of the property, that the owner(s) consent to the request for a Variance. Certification is not necessary if the owner is the applicant; and __ A sealed site plan to scale that clearly illustrates the requested Variance in relation to the affected site and to the surrounding parcels and uses. A reproducible copy of this plan, no larger than 11” x 17”, must be submitted. In addition, please include or email the site plan in PDF format; and __ Filing Fee: $150.00 What are the extraordinary and/or exceptional conditions that apply to your parcel? How do these conditions differentiate your parcel from those in the immediate vicinity? How would these conditions and the application of the Ordinance to your particular lot effectively prohibit or unreasonably restrict the utilization of your property Will the authorization of a variance be of substantial detriment to adjacent property or to the public good? Will the character of the district be harmed by the granting of the variance? Index to Drawings Sheet 01 - Cover sheet Sheet 02 - Crawl Foundation Sheet 03 - Floor 1 Plan Sheet 04 - Front and Right Elevations Sheet 05 - Rear and Left Elevations Sheet 06 - Details - Buiiding Section Sheet 07 - Electrical - Roof Sheet 08 - Slab Sheet Drawing Index Crawl Foundation Plan _Fdn8blk _Fl1blk8-4 _crawl notes _ledgerblk8-4 Door List RT Floor 1 Plan Kitchen Cabinets Kitchen Cabinets Window List RT Front Elevation Right Side Elevation _deck rail 1 Left Side Elevation Rear Elevation -eaveSid9box18-4 -porch8"col -rakeAttic12boxed Building Section _insulation chart Electrical 1 Floor Plan Roof Plan 40psf live load 10psf dead load2x12 12"o.c.16"o.c.24"o.c.floor joist 30psf live load 10psf dead load(sleeping rooms @ L/360) (all rooms except sleeping) 2x12 ceiling joist 2x6 2x8 rafters 20psf live load 10psf dead load 30psf live load psf dead load 50psf live load psf dead load 2x6 2x8 2x6 2x8 2x6 2x8(slope over 3/12 no finished clg @ L/240) #2 southern yellow pine (#1syp) #2 S-P-F(spruce-pine-fir) 40psf live load 10psf dead load 2x10 20'-7" 17'-3" 17'-10'' 15'-5" 14'-7" 12'-7" 12"o.c.16"o.c.24"o.c.floor joist 30psf live load 10psf dead load (sleeping rooms @ L/360) (all rooms except sleeping) 2x12 2x10 23'-0" 19'-0" 19'-11" 17'-2" 16'-3" 14'-1" ceiling joist 2x6 2x8 2x10 14'-9" 18'-9" 22'-11" 12'-10" 16'-3" 19'-10" 10'-6" 13'-3" 16'-3" rafters 20psf live load psf dead load 30psf live load psf dead load 50psf live load psf dead load 2x6 2x8 2x6 2x8 2x6 2x8 16'-3" 21'-0" 14'-4" 18'-2" 11'-9" 14'-10" 13'-9" 17'-5" 11'-11" 15'-1" 19'-9" 12'-4" 11'-3" 14'-3" 9'-9" 12'-4" 7'-11" 10-'1" 19'-1" @#2(21'-11" @#1) 21'-4" @#2(24'-2" @#1) 16'-6" @#2(19'-1" @#1) 18'-6" @#2(21'-4" @#1) 13'-6" @#2(15'-7" @#1) 15'-1" @#2(17'-5" @#1) 13'-11" @#2 (15'-6" @#1) 17'-7" @#2(20'-5" @#1) 12'-0" @#2(14'-0" @#1) 9'-10" @#2(11'-5" @#1) 12'-6" @#2(14'-6" @#1) 15'-3" @#2(17'-9" @#1) 10 10 (slope over 3/12 no finished clg @ L/180) (GWB ceiling @ 10 psf dead load L/240) (GWB ceiling @ 10 psf dead load L/240) 10 10 10 15'-7" 19'-8" 13'-6" 17'-1" 12'-3" 15'-7" 12'-11" 16'-4" 11'-2" 14'-2" 9'-2" 11'-7" 10'-6" 13'-4" 9'-2" 11'-7" 7'-5" 9'-5" 2x10 2x10 16'-2" @#2(18'-0" @#1) 18'-1" @#2(19'-10" @#1) 14'-0" @#2(16'-1" @#1) 15'-8" @#2(18'-0" @#1) 11'-5" @#2(13'-3" @#1) 12'-10" @#2(14'-8" @#1) 2x12 2015 IRC and the 2018 NCRC General Notes Structural Notes Energy Notes These plans are designed for roof loads of 20 psf live load and 10 psi dead load. The chart to the left can be used to adjust for different requirements. All beams are labeled "LVL" and should be sized locally. Roof loads can vary and have a big impact on the beams carrying accumulated loads. Most Lumber suppliers can have this engineered for their product. • Square footages are for heated floor areas. This does not include fireplace projection or vaulted space. Stairs are counted on the main floor only. • Dimensions are from the face of the stud wall. Contractor to verify all dimensions and please contact us if an error is present.. • All footings shall be on firm undisturbed soil of no less than 2000 psf and be below frost depth. The exact size and reinforcement of concrete footings must be determined by local soil conditions. • HVAC design to be sized according to the local climate conditions including compass direction. • Caulk all exterior toe plates with latex caulk. • Caulk all wire and pipe holes where they penetrate all upper and lower exterior plates. • Use blown-in wall insulation if at all possible. If batt insulation is used pack behind all electrical boxes. • Seal all joints in HVAC ducts, with leakage no more than 3%. Three inch fiber mesh tape should be used on all collar to plenum connections and all gaps that are 1/4" or wider. Insulate ducts with R-6.5 or greater. • Foam insulate between all exterior window and door edges and rough opening frame. Use non-expanding foam. • Provide back draft damper on kitchen hood vent, dryer vent, and bathroom vents. • Insulate all hot water pipes. • Install wrap kit on water heater. Thank you for your purchase of these house plans. These plans are designed to conform to the 2018 IRC, 2021 IRC and the 2018 NCRC including local state amendments. National and local building codes vary with location and change from time to time. Therefore it is impossible to warrant compliance to your specific location. It is the responsibility of the purchaser and/or the builder to adapt these plans to the requirements of the individual locale. Wall bracing notesContinuious 7/16" osb sheathing - typical - CS-WSP.Wall bracing shall be in accordance to IRC/NCRC Section 602.10.3. The required length of bracing for each side of arectangle circumscribed around the plan or a portion of the plan at each story level shall be determined using TableR602.10.3 and Figure R602.10.3(1). The cumulative contributing length of braced wall panels assigned to a rectangleside shall be greater than or equal to the required length of bracing specified in Table R602.10.3. The followingadditional requirements shall apply. Limitations - The continuous sheathing requirements of Section R602.10.3 shall be limited to bracingmethod CS-WSP in accordance with Table R602.10.1 with the following conditions of use: 1. Basic design wind speed shall not exceed 115 mph. 2. Wall height at each story level shall not exceed 12 feet. 3. Eave to ridge height shall not exceed 20 feet. 4. Exterior walls shall be sheathed on all sheathable surfaces including infill areas between bracedwall panels, above and below wall openings, and on gable end walls. 5. Except when used for bracing method GB, the interior side of exterior walls and both sides ofinterior walls shall be sheathed continuously with minimum 1⁄2-inch-thick gypsum wall board interior finishfastened in accordance with Table R702.3.5, or approved interior finish of equivalent or greater shearresistance Unless required for fire separation by Section R302.6, gypsum board shall be permitted to beomitted where the required length of bracing, as determined in Table R602.10.3, is multiplied by 1.40. 6. Floors shall not cantilever more than 24 inches (607 mm) beyond the foundation or bearing wall below. Requirements - The required length of bracing for each side of a rectangle circumscribed around the planor a portion of the plan at each story level shall be determined using Table R602.10.3 and FigureR602.10.3(1). The cumulative contributing length of braced wall panels assigned to a rectangle side shall begreater than or equal to the required length of bracing specified in Table R602.10.3. The following additionalrequirements shall apply. 1. Braced wall panels on exterior or interior walls shall be assigned to the nearest rectangle side asshown in Figure R602.10.3(2) for each story level floor plan. 2. Braced wall panels shall be distributed and installed in accordance with Figure R602.10.3(3). 3. A minimum of one-half the required bracing amount for each rectangle side should be locatedon exterior walls within 8 feet of the location of the rectangle side. 4. Interior braced wall panels using Method GB shall be assigned to the closest parallel rectangleside and shall contribute 0.5 times their actual length. The narrowest width of braced wall panels allowedfor GB is 48”, and the 0.5 accounts for GB being half the strength of other methods except LIB. 5. The bracing amount provided on an upper story building side shall be deemed-to-comply where itequals or exceeds the amount of bracing required for the story immediately below. 6. Where the bracing amount provided on an upper story equals or exceeds the amount of bracingrequired for the story below, an analysis of bracing shall not be required for the upper story. 7. CS-WSP Continuous sheathed WSP method to have - Minimum braced material thickness or size 7/16".Minimum brac panel length or brace angle 24" adjacent to window not more than 67% of wall height; 30" adjacent todoor or window greater than 67% and less than 85% of wall height. 48" for taller openings. Fasteners 6d common nailor 8d (2 1/2" long x 0.113" diameter) nails. See table R602.3(3). Space 6" edges and 12" field. Wall Header NotesHeaders 3' or less to be 2-2x6 with 1 jack each side Headers 4' - 6' to be 2-2x8 with 2 jacks on each side Beams 4' to 6' to be 2-2x12 with 2 jacks on each side or 3" min bearing and footing under point loads. © Rick Thompson -2023 abbreviations cj ceiling joist clg. ceiling CMU concrete masonry unit C.O cased opening conc. concrete CT. ceramic tile dbl. double dj double joist ew. each way fj floor joist ftg. footing HVAC heating/ventilating/air conditioning jst. joist LVL. laminated veneer lumber -ie.Parallam mech. mechanical mil .001 inch min. minimum N.T.S. not to scale oc on center pc pull cord pt. pressure treated psf pounds per squarefoot R/A return air reqd. required reinf. reinforcing Rm. room ro. rough opening sf square feet syp southern yellow pine Shw. shower T&G tongue and groove W.H. water heater WWM welded wire mesh vif verify in field yp yellow pine The Small Print - These house plans are not licensed to anyone other than the partylisted on each sheet. They are not transferable to any builder, or subcontractorwho is hired to build the house, nor their friends nor their family. If any modificationsare made to these plans with a PDF editor, they must include the persons' name whois changing these plans, and the date of the changes. If the type font anywhere on thesedrawings is different than "this", it has been altered. PDF’s are now the industry standard.I appreciate the plan reviewers who have given me feedback on this issue. I try toprovide very good house plans and they are very reasonably and fairly priced.I am happy to sell them, and appreciate those who do not steal them, but rather purchasethem legally. Thank you, Rick Thompson Asheville, NC 828-734-2553 info@thompsonplans.com w w w. t h o m p s o n p l a n s . c o m Plan 1216A 4/22/24 original print date This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING General crawl notes Provide 18"x24" min. access door. Location as per field conditions - side prefered. Provide foundation vents not less than 1 sqft per 150 sqft under floor space. One vent within 3 feet of each corner. IRC - R408.1 or Unvented where exposed earth is covered and and air supplied as per IRC - R409 Fill piers solid with grout. Pier block size shown is minimum. May vary as per foundation height. Pier spacing may vary dependent on local snow loads, soil bearing capacity and the use of roof trusses. Footing sizes and reinforcement are assumed. Soil conditions vary and must be taken into account. Inspectors can allow builders to adjust the use of rebar and footing sizes as per local conditions. Girders may be sized with LVL's to reduce piers. Up size footing accordingly (30"x30"x10" min w/ 4-#4's each way) and16"x16" filled piers. See separate drawing for LVL's Separate double joist under plumbing walls 3 1/2" align top of decking with top of sub-floor drop joist 1/4" 5/4"x 6" PT decking flashing tucked 4" min under siding w/10 degree slope over ledger pressure treated joist see plans for size 2x PT ledger joist hangers siding to be 2" min. above surface of deck notch over flashing for water flow scale 1"=1'-0" W5 see wall detail for additional notes 18" min - 24" prefered scale 1"=1'-0" Wall detail Fl1 2x6 pt plate 5/8" thru bolts w/ washer -20"' O.C. staggered and 12" min from ends caulking or sealant for air movement control 2x4 studs at 16" o.c. alternate 2x6 studs gypsum wall board wall insulation see zone chart stucco finish scale 1"=1'-0"W1 18" min - 24" prefered scale 1"=1'-0" Wall detail Fl1 1/2" sheathing - wood for wall bracing and shear 3/4" sub-flooring glued and nailed siding 2x10 floor joist or floor trusses by others styrofoam sill sealer floor insulation see zone chart 2x6 pt plate caulking or sealant for air movement control 2x4 studs at 16" o.c. alternate 2x6 studs gypsum wall board wall insulation see zone chart 1/2" anchor bolts @ 6' O.C. max 7" min embed into solid grout 12" max from ends/corners/breaks 2x 10 rim joist as per local frost depth 3" 10" 2'-0" full mortar bed stucco over block 6 mil film slope top of footing with mortar 2 #5 rebar - if required by local codes 8" masonary units vertical rebar if needed- determined by height of unbalanced backfill see IRC section R404 Foundation - block wall scale 1"=1'-0"F4 concrete footing - size may vary as per local soil conditions and code requirements - 3000 psi Soil to have min 2000 bearing capacity 2-2x10 2-2x10 pt 3-2x10 8x16 concrete block piers on 24"x24"x10" footings w/ 3#4 bars each way - typical 2-2x10 2-2x10 pt 6x6 pt post 24"x24"x10" conc. ftg w/ 3-#4's each way 2x PT ledger through bolted to band joist w/ 5/8" bolts 24" o.c. staggered to prevent splitting 2x PT ledger through bolted to band joist w/ 5/8" bolts 24" o.c. staggered to prevent splitting 6x6 pt post 24"x24"x10" conc. ftg w/ 3-#4's each way F4 F6 Crawl Foundation Plan scale 1/4"=1'-0" 2x10 #2 syp. @ 16" oc 5/4x6 pt decking 16" o.c. 2x10 #2 syp. @ 16" oc 5/4 PT decking 2x10 PT jst. @ 16" oc 2x8 pt joist 2x10 #2 syp. @ 16" oc 2x10 #2 syp. @ 16" oc 9'-0" 17'-0" 26'-0" 13'-9" 12'-3" 8'-0" 5'-9" 58'-0" 56'-4 1/2" 53'-1 1/2" 11'-7 1/2" 38'-4 1/2" 8'-0" 58'-0" 11'-7 1/2" 3" 5'-1/2" 3" 10'-1/2" 3"2'-1/2"3" 10'-1/2" 3" 5'-1/2" 3"2'-1"3" 10'-4" 12'-10 1/2" 3" 25'-3" 6'-0" 4'-10 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-2 1/2"1'-4" 4'-10 1/2" 8'-0" 13'-7" 4 1/2" 11'-11" B1 B1 2 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING Door List Width 2'-0" 2'-4" 2'-6" 3'-0" 3'-0" 4'-0" 4'-6" 5'-0" 5'-0" Height 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" Name RD02 Swing RD02 Swing RD02 Swing RD01 Door ST RD02 Swing RD05 Bifold RD02 Swing RD05 Bifold RD02 Swing Type Interior Interior Interior Exterior Interior Interior Interior Interior Exterior Quantity 2 5 3 1 1 3 1 1 1 18 Window List W x H Size 1'-6"×2'-6" 1'-6"×3'-0" 2'-0"×3'-2" 2'-4"×5'-2" 2'-8"×4'-6" 3'-4"×5'-2" 4'-0"×1'-0" 5'-4"×4'-6" 5'-4"×5'-2" Units Attic vent Attic vent Single Single Single Single Single Twin Twin Window Type Vent Window 26 RW3-5 Gable RW1-4 Doublehung RW1-4 Doublehung RW1-4 Doublehung RW1-4 Doublehung RW1-6 Glider RW1-4 Doublehung RW1-4 Doublehung Quantity 1 1 1 1 2 1 1 2 1 11 1'-3"1'-7" 2'-6" 2'-6" 2'-6" 3'-6" Scale 3/8" = 1'-0" Kitchen Cabinets1 2 DW F 5'-0" 6'-8" 5'-2" 2'-4" 4'-6" 5'-4" 5'-4" 5'-2" 3'-0" 6'-8" 6'-8" 4'-6" 6'-8" 2'-4" 5'-4" 4'-6" 4'-0" 1'-0" 2'-0" 3'-2" 4'-6" 2'-8" 4'-6" 2'-8" 3'-4" 5'-2" 6'-8" 2'-4" 6'-8" 2'-4" 2'-6" 6'-8" 6'-8" 4'-0" 6'-8" 4'-0" 2'-6" 6'-8" 6'-8" 4'-0" 6'-8" 2'-6" 2'-0" 6'-8" 5'-0" 6'-8" 2'-0" 6'-8" 2'-4" 6'-8" 2'-4" 6'-8" 6'-8" 3'-0" 11'-7 1/2" 3 1/2" 12'-3 1/2" 3 1/2"2'-0"3 1/2" 13'-0" 3 1/2" 5'-0"3 1/2"2'-0"3 1/2" 10'-4" 8'-3" 5'-6" 6'-1 1/2" 6'-1 1/2" 4'-4 1/2" 10'-9" 3'-0" 3 1/2" 11'-11 1/2" 58'-0" 26'-0" 13'-9" 12'-3" 9'-0" 17'-0" 58'-0" 11'-7 1/2" 38'-4 1/2" 8'-0" 3'-3" 10'-5 1/2" 3'-3" 3'-5 1/2" 3'-0" 5'-2 1/2" 12'-10" 3 1/2" 25'-3" 6'-0" 6'-3" 17'-0" 2'-0" 3'-4" 3'-4" 3'-6" 3'-5 1/2" 5'-5" 3'-0" 4'-9"3 1/2"5'-4 1/2"3 1/2" 6'-3 1/2" 5'-9" 3 1/2" 5'-11" 6'-6" 5'-1 1/2" 1 2 alt. location for WH if not possible in crawl space d w kit main br br #4 dining living rm clo clo scale 1/4"=1'-0" Floor 1 plan attic access HVAC in cral space or attic with slab conditions clg jst/trusses see chart br #3 bathbath clo clo wh clg jst/trusses see chart Floor 1 plan 1293 sq.ft. stor stor clo B1 B1 3 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING -10" -1 foundation -10" -1 foundation ±0" 1 Floor 1 ±0" 1 Floor 1 +8'-1" 2 Ceiling +8'-1" 2 Ceiling 30"x24" louver 9/12 pitch rake mould 3" crown on 1x8 drip cap 5/4" x 6" casing 5/4" x 6" corner board siding 8x8 column lattice panel Front Elevationscale 1/4" =1'-0" E4 -10" -1 foundation -10" -1 foundation ±0" 1 Floor 1 ±0" 1 Floor 1 +8'-1" 2 Ceiling +8'-1" 2 Ceiling roof vent siding 5/4" corner boards Right Side Elevationscale 1/4" =1'-0" 7 1/2"7 1/2" 2'-0" 1'-0" 6" 3'-0" 5/4x6 pt decking pt joist rail to resist 200 lbs from any direction 2x2 pt pickets - 4" o.c. 3/4" x 3" x 3" "L" bracket screw to 3-2x6 PT column frame before wrapping w/1x stock 1x4 pt - nail from top into pickets 2x4 pt - fasten to 4x4's w/ galvanized metal clips 4x4 pt post pt ledger or joist hangers lattice 1 x 10 alt skirt board 2x12 pt treads - paint finish round leading egde with 1/2" bit 1x8 pt - paint finish 2-2x10 PT 1x8 pt - paint finish 2x12 pt stringers - 2' oc max 2x12 pt treads - paint finish round leading egde with 1/2" bit metal connector- set into concrete footing w/ "J" bolt min. embed 7" concrete footing - size may vary as per local soil conditions and code requirements 4" x 12" concrete base 2x6 PT notch 6x6 for 2x10's 2x6 pt cap - tapper edges rail at between 34" and 38" maximum triangular opening to not allow 6" sphere passage 5/8" thru bolts 2x10 PT @ stringer Simpson LSCZ or equal 5/8" carriage bolts 2x12 pt stringers - 2' oc max scale 1"=1'-0" Deck Detail rail and steps to comply with R 311.7 and R312 rail openings to not allow a 4" diameter ball to pass thru rail at steps to be 2'-10" high F6 4x4 pt posts at step bottom into 9" dia min. concrete hole 2 #4 rebar each way - if required by local codes (recommended always) 4 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING -10" -1 foundation -10" -1 foundation ±0" 1 Floor 1 ±0" 1 Floor 1 +8'-1" 2 Ceiling +8'-1" 2 Ceiling roof vent siding 9/12 pitch 18x30 louver 5/4x6 corner boards 5/4x6 casing Rear Elevationscale 1/4" =1'-0" -10" -1 foundation -10" -1 foundation ±0" 1 Floor 1 ±0" 1 Floor 1 +8'-1" 2 Ceiling +8'-1" 2 Ceiling siding ridge vent Left Side Elevationscale 1/4" =1'-0" 5 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING -10" -1 foundation -10" -1 foundation ±0" 1 Floor 1 ±0" 1 Floor 1 +8'-1" 2 Ceiling +8'-1" 2 Ceiling 18'-10" 6 mil film roof trusses to match this profile 9/12 pitch collar ties brace roof to bearing wall see span tables on cover sheet see insulation cahrt see chart see chart Scale 1/4" = 1'-0" Building Section B1 1'-0" 2x4 look out beyond 3/16" A/C exterior plywood or 1x6 "v" groove paneling 2x4 nailer 1x8 and 3" crown common rafter see chart 1/2" plywood or OSB siding 2x4 studs at 16" o.c. alternate 2x6 studs roofing material 1/2" structural sheathing 15 lb. felt metal drip edge 1x8 rake mold Typical RakeE4 - boxed soffit scale 1"=1'-0" 3 4 except Marine 5& Marine 6 7 8 .32(.35) NR 13 131 2 Check appropriate climate zone as determined by local building dept. 0 13 .35 0 Climate Zone .32 .32 .32 38 030 19 038(or 30ci) 1910/13(10/15)20 or13+5h 30g Glazing U-factor Ceilings R-value Wood frame wall R-value Floors R-value Basementc walls R-value Minimum Insulation ChartTable N1102.1 - IRC 2018 & (2021 NCRC - in parentheses)Insulation and fenestration requirements by components a 49 30g15/1910, 2' 49 15/19 49 15/19 Crawl spacec wall R- value 0 5/13 0 R value and depth Slabd perimeter 10, 2'(10, 2') 10, 4' 10, 4' 10/13(10/15) 0 5/13f 38g 38g 13 Glazes fenestration SHGCb,e .25 .40 NR NR NR NR a - R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R-value of the insulation shall not be less than the R-value specified in the table. b - The fenestration U-factor column excludes skylights. The SGHC column applies to all glazed fenestration. d - R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Zones 1 through 3 for heated slabs. For monolithic slabs, insulation shall be applied from the inspection gap downward to the bottom of the footing or a maximum of 24 inches below grade whichever is less. For floating slabs, insulation shall extend to the bottom of the foundation wall or 24 inches, whichever is less. e - There are no solar heat gain coefficient (SGHC) requirements in the Marine Zone. g - Or insulation sufficient to fill the framing cavity, R-19 .40 .35 20 or13+5h h - “13+5” means R-13 cavity insulation plus R-5 insulated sheathing. If structural sheathing covers 25 % or less of the exterior, insulating sheathing is not required where structural sheathing is used. If structural sheathing covers more than 25 percent of exterior, structural sheathing shall be supplemented with insulated sheathing of at least R-2. f - Basement wall insulation is not required in warm-humid locations as defined by Figure 301.1 and Table 301.1. c - “15/19” means R-15 continuous insulated sheathing on the interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. “15/19” shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulated sheathing on the interior or exterior of the home. “10/13” means R-10 continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. (“10/15” means R-10 continuous insulated sheathing on the interior or exterior of the home or R-15 cavity insulation at the interior of the basement wall or crawl space wall.) .25 .25 20 or13+5h 20 or13+5h 20 or13+5h 20 or13+5h 15/19 15/19 49 (38or 30ci) i - The second R-value applies when more than half the insulation is on the interior of the mass wall. 49 (38or 30ci) (15 or13+2.5h)(15 or13+2.5h)(19n or13+5h) 10/13(10/15) 10, 2'(10, 2')10/13(10/15)15/19(10/19) 7 1/2"7 1/2" 2'-0" 1'-0" 6" 3'-0" 5/4x6 pt decking pt joist rail to resist 200 lbs from any direction 2x2 pt pickets - 4" o.c. 2x6 pt cap - tapper edges 1x4 pt - nail from top into pickets 2x4 pt - fasten to masonary w/ galvanized metal clips and masonary anchors 8x8 wood column 3-2x6 pt core tie 2x6 core to framing with metal post connector 3/4" x 3" x 3" "L" bracket screw to masonary column w/masonary anchors pt ledger or joist hangers lattice 1 x 10 alt skirt board 2x12 pt treads - paint finish round leading egde with 1/2" bit 1x8 pt - paint finish 2-2x10 PT 1 x 8 base w/ base cap 3-2x6 PT column - wrap w/1x stock 1x8 pt - paint finish 2x12 pt stringers - 2' oc max 2x12 pt treads - paint finish round leading egde with 1/2" bit metal connector- set into concrete footing w/ "J" bolt min. embed 7" concrete footing - size may vary as per local soil conditions and code requirements 4" x 12" concrete base 2x6 PT notch 6x6 for 2x10's rail at between 34" and 38" maximum triangular opening to not allow 6" sphere passage 5/8" thru bolts 2x10 PT @ stringer Simpson LSCZ or equal 5/8" carriage bolts 2x12 pt stringers - 2' oc max Porch Detail scale 1"=1'-0" Strap tie column core to floor framing to prevent wind up lift. rail and steps to comply with R 311.7 and R312 rail openings to not allow a 4" diameter ball to pass thru rail at steps to be 2'-10" high F6 4x4 pt posts at step bottom into 9" dia min. concrete hole 2 #4 rebar each way - if required by local codes (recommended always) 1'-6" 1x8 and 3" crown continuous soffit vent 1x8 gutter 3/16" A/C exterior plywood or 1x6 "v" groove paneling roofing material ceiling insulation see zone chart ceiling joist - see floor plan for size and spacing metal drip edge rafter ties @ 48" oc as per IRC- R 802.3.1 - 2x6, metal strap or other approved method 2x4 plate nailed to rim & joist roof tie downs where wind uplift pressures exceed 20 lb/sq IRC-802.11 1/2" structural sheathing 15 lb. felt 1/2" plywood or OSB siding gypsum wall board wall insulation see zone chart 2x4 studs at 16" o.c. alternate 2x6 studs 2-2x4 top plate caulking or sealant for air movement control 1" air space/baffle min scale 1"=1'-0" - rafters on joist Alternate roof trusses to be raised chord trusses 12 9 see chart on cover sheet for max unbraced rafter spans E1 Typical Boxed Eave 6 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING 3'-5 1/2" 1'-6" 1'-0" Roof vent as reqd 9/12 pitch Roof plan scale 3/16"=1'-0" B1 B1 DW F 220 SD SDSD SD Electrical - Floor 1 Plan scale 3/16" = 1'-0" 7 info@thompsonplans.com Asheville, North Carolina 828-734-2553 T h o m p s o n P l a n s . c o m standard contract document All Federal, State and local codes shall be considered as a part of these documents, and shall take preference over anything shown or implied if differences arise. © 2023 Rick Thompson 4/22/24 original print date plan # 1216A This plan is licensed to Angel Cardona THIS COPY IS FOR ESTIMATING ONLY AND IS NOT FOR PRINTING OR PERMITTING Planning Department PO Box 1749 • Spartanburg, SC 29304 • Phone: (864) 596-2068 • email: planning@cityofspartanburg.org website: www.cityofspartanburg.org TO: The Board of Zoning Appeals RE: VAR-24-002-00011: The City of Spartanburg’s Board of Zoning Appeals has received a request for a variance to the front and interior side lot setback for property located at 187 Carlisle Street (TMS: 7-12-14-286.00); with a zoning designation of R -8 SFD (Ge neral Residential – Single- family District). Owner: Thomas Wooten / Applicant: Gabriel Weisser; Taylored Homes. Date: May 14, 2024 Project Description and History The project site is an approximately 6800 square feet lot located at 187 Carlisle Street (TMS: 7 -12-14- 286.00); with a zoning designation of R-8 SFD (General Residential – Single-family District). The site is located in a traditional single-family neighborhood and surrounded by other single -family lots . The applicant is requesting a variance to the front and interior side setbacks. The applicant received approval to develop a single -family home on the property consisted with the Board of Architectural Design and Historic Review (HARB) standards. On October 12, 2023, the City of Spartanburg’s Board of Architectural Design and Histor ic Review (HARB) approved the design of the structure in the Hampton Heights Neighborhood Historic District on a vacant lot. At that meeting, the city as a condition of approval failed to require the applicant to submit an application to the Board of Zoning Appeals (BZA) for the setback requirements for the front setback to be consistent with the historic district. Staff expedited the application to bring it before the Board to address the front and side setback requirements. Variances from the regulations of this Ordinance shall be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and may be granted only in the following instances and in no others: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; (*) 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; 4. To permit the same off -street parking facility to qualify as required facilities for two or more units, provided that substantial use of such facility by each use does not take place at approximately the same hours of the same days of the week; 5. To reduce the applicable off -street parking or loading facilities required by not more than one (1) parking space or loading space, or twenty -five percent (25%) of the required facilities, whichever number is greater; 6. To allow for the deferment of required parking facilities for a reasonable period of time, such period of time to be specified in the variance; 7. To increase by not more than forty percent (40%) the maximum distance that required parking spaces are permitted to be located from the use served; Page 2 of 14 8. To permit the height of a fence in the required rear, side and corner side yard to exceed the maximum height allowed by this Ordinance up to eight (8) feet when property is exposed to exceptional nuisances of traffic, dust, noise, glare, and vandalism; and (*) 9. To reduce the setback requirement for portable signs provided that no variance shall be granted to permit such signs within the triangular area formed by the right-of-way lines of intersecting streets (or a street and a driveway), and a line joining points on the right-of-way lines twenty-five (25) feet from the point of their intersection. If the property in question has no defined driveway to its parking area the Board shall satisfy itself that the proposed location of the portable sign will not interfere with traffic by blocking reasonable sight lines for streets, sidewalks and driveways before any variance is granted. The application for such variance shall be accompanied by a scaled drawing showing all information relevant to the variance request. (**) Analysis Zoning Ordinance Consistency The project site is an approximately 6,800 square feet lot located at 187 Carlisle Street (TMS: 7 -12-14- 286.00); with a zoning designation of R-8 SFD (General Residential – Single-family District). The site is located in a traditional single -family neighborhood and surrounded by other single -family lots. The applicant is requesting a variance to the front and interior side setbacks. The applicant received approval to develop a single -family home on the property consisted with the Board of Architectural Design and Historic Review (HARB) standards. Based on Section 603.4(1-3) Variances, the Board has the authority to permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; The Board must utilize Section 603.4(1-3) and determine if the proposal meets all the criterion for approval. To hear and decide appeals for a Variance from the requirements of the Zoning Ordinance when strict application of the provisions of the Ordinance would result in unnecessary hardship. A Variance may be granted in an individual case of unnecessary hardship if the Board makes and explains in writi ng the following findings: a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; b. These conditions do not generally apply to other properties in the vicinity; c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and d. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance. e. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surrounding area or to promote the public health, safety, or general welfare. Page 3 of 14 Findings 1. There are extraordinary and exceptional conditions pertaining to the particular piece of property – No. There are no extraordinary and exceptional conditions pertaining to the particular piece of property. The project site is an approximately 6800 square feet lot located at 187 Carlisle Street (TMS: 7-12-14-286.00); with a zoning designation of R-8 SFD (General Residential – Single-family District). The site is located in a traditional single-family neighborhood and surrounded by other single-family lots. The applicant is requesting a variance to the front and interior side setbacks. The applicant received approval to develop a single -family home on the property consisted with the Board of Architectural Design and Historic Review (HARB) standards. All other structures on lots that have front setbacks that are less than 20 feet on the street and the neighborhood. 2. These conditions do not generally apply to other properties in the vicinity – Yes. There are several lots in the area that have similar conditions. A review of the lots in previous BZA cases indicated side lot setbacks of 5 feet and front yard setbacks less than 20 feet. 3. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property; and – No. The application of the ordinance would not unreasonably restrict the utilization of the property. The property can still be used in its current condition but would not be consistent with other structures on the lot in the street and in the neighborhood. 4. The authorization of a Variance will not be of substantial detriment to the adjacent property or to the public good, and the character of the district will not be harmed by the granting of the Variance– Yes. The authorization of a variance will not be of substantial detriment to the adjacent property or to the public good, and authorization of the district will not be harmed by the granting of the variance. The side yard setbacks would meet the 80% rule, the front yards setback would not mee t the requirements. All other requirements in Section 603 will be met with the approval of the variance. 5. In granting a Variance, the Board may attach to it such conditions regarding the location, character, or other features of the proposed building, structure, or use as the Board may consider advisable to protect established property values in the surroundin g area or to promote the public health, safety, or general welfare– No. Staff does not recommend any additional conditions be considered. The v ariance from the regulations of the zoning can be granted by the Board of Zoning Appeals only in accordance with the standards established in section 603, and can be granted in the following instances: 1. To permit any yard less than the requirements of this Ordinance; 2. To permit the reduction of any required setback being in compliance with all applicable Building and Fire Codes and subject to review by the Building Official; 3. To permit the use of a lot or lots for a use otherwise prohibited solely because of the insufficient area or width of the lot or lots, but in no event shall the respective area and width of the lot or lots be less than eighty percent (80%) of the required area and width; Summary and Recommendation Staff recommends approval of the Variance. The proposed request meet s all the required Findings for approval of the Variance except the 80% limits requirements for the front yard setback. The Board has the Page 4 of 14 authority to approve the front yard setbacks because of the other consistent conditions on the street and the neighborhood. In exercising its powers, the Board of Zoning Appeals may, in conformity with the provisions of Section 603, reverse or affirm, wholly or in part, or may modify the order, requirements, decision, or determination, and to that end, has all the powers of the of ficer from whom the appeal is taken and may issue or direct the issuance of a permit. The board, in the execution of the duties specified in this chapter, may subpoena witnesses and in case of contempt may certify this fact to the circuit court having jurisdiction. A ll final decisions and orders of the board must be in writing and be permanently filed in the office of the board as a public record. All findings of fact and conclusions of the law must be separately stated in final decisions or orders of the board which must be delivered to parties of interest. S ubmitted by: M artin L. Livingston, Jr., AICP, CPM Community Development Director A ttachments: Conditions of Approval Application Photos Page 5 of 14 CONDITIONS OF APPROVAL FOR THE PROJECT ON PROPERTY LOCATED AT: 187 Carlisle Street (TMS: 7-12-14-286.00) 1. If one or more of the following conditions is not met with respect to all its terms, then this approval may be revoked. 2. All setbacks excluding the interior side yard and front yard setback shall meet the setback requirements in the City of Spartanburg Zoning Ordinance, except what is currently approved by the Board of Zoning Appeals. 3. The use shall meet the standards and shall be developed within the limits established by Chapter 501.10 of the Spartanburg Municipal code as to the emission of noise, odor, smoke, dust, vibration, waste, fumes or any public nuisance arising or occurring incidental to its establishment or operation. 4. The applicant shall be responsible for the completeness and accuracy of all forms and supporting material submitted in connection with any application. Any errors or discrepancies found therein may result in the revocation if any approval or permits issues in connection therewith. 5. The development of the site shall be in substantial accordance with the approved plans submitted and on file in the Spartanburg City Planning Department. All aspects of construction must be completed prior to use. Major modifications to plans or exceptions to completion may be granted only by the City authority which approved the project. 6. All requirements of the Building, Fire, Water and Streets and Stormwater Departments shall be completed prior to building occupancy permit issuance and continuously maintained thereafter. 7. Site Pre-construction meeting with the City of Spartanburg Storm Water Manager, Jay Squires, is required prior to site disturbance. Building pre -construction meeting with City of Spartanburg Building Official, Buddy Bush, required prior to vertical construction. Page 6 of 14 SITE MAP Page 7 of 14 ZONING MAP Page 8 of 14 Table 401 – (A) Table of Area Dimensional Requirements Page 9 of 14 Page 10 of 14 Page 11 of 14 Page 12 of 14 Page 13 of 14 Site Photos Page 14 of 14 Site Photos

Source: City of Spartanburg website. First collected Nov 1, 2026.