EDGEFIELD COUNTY BUILDING & PLANNING
210 PENN ST. EDGEFIELD, SC 29824
(803) 637-4073
Installing Your Manufactured Home In
Edgefield County
South Carolina
Contacts:
Edgefield County Building & Planning (803) 637 - 4073
Edgefield County Tax Assessor (803) 637 - 4066
DRIVEWAYS:
Edgefield County Road (803) 637 - 4073
S.C. Dept. of Transportation (State Road) (803) 637 - 6511
ELECTRIC COMPANIES:
Aiken Electric Cooperative (803) 637 - 3189
South Carolina Electric & Gas (803) 275 - 2534
WATER & SEWER:
DHEC (Department of Health & Environmental Control (803) 637 - 4035
DHEC (Aiken Office-206 Beaufort St, NE, Aiken, SC) (803) 642 - 1637
Edgefield County Water & Sewer (803) 637 - 3011
MANUFACTURED HOME CHECKLIST
1. Get a tax map number from the Tax Assessor’s office.
2. Bring copy of plat for approval to the Edgefield County Building & Planning Office. Once approved you will receive a Site
Approval form to take to the DHEC office for a septic permit. If you have an existing septic tank please contact a Certified
Septic Tank Installer for an Approval Letter. If you are on County Water and/or Sewer, go to Edgefield County Water and
Sewer Authority (ECW&S) for approval to connect. The fee will be set by DHEC or the Water and Sewer Authority. We
require a copy of the authorizations and/or test results from DHEC and/or ECW&S prior to any further work.
3. Get a 911 address from the 911 Administration (637-4106).
4. Register the home in the Tax Assessor’s Office. The fee is $10.00. The following paper work is required: a sta mped site
approval form from the Edgefield County Building and Planning Department and Form 400 or title. Form 400 comes from the
dealer. A decal will be issued. This decal should be placed on a window facing the driveway.
5. After the home is registered, go to the Edgefield county Building & Planning Office and pay the mobile home fee (depending
on cost of home).
6. Alternative Methods of installation MUST be approved by the Manufacturer.
7. Installer must have a moving permit if the home is not being purchased from a dealer. This permit is issued from the
County that the home is being moved from. The Edgefield County moving fee is $50.00 and is issued by the Tax Assessor’s
Office (803-637-4066).
8. After installation is completed, you will need to contact the Edgefield County Building & Planning Office for a final
inspection. The following items must be complete: Anchors, Piers, sewer and water pipes (must leave an opening in the
underpinning), also septic tank installed or sewer hooked up, copy of final septic tank approval from DHEC, landings with
steps and handrails in place, landing secured to ground, electrical complete, 911 address posted (visible and legible from th e
street or road fronting the property), tax decal in window, driveway completion and u nderpinning. The tongue and tires
must be removed. If you desire to leave tongue on, you must pay a tongue deposit of $150.00 at the Treasurer’s Office. A
form to authorize the deposit must be obtained from the Building and Planning Department. The fee is refundable if the
home is moved out of Edgefield County.
9. If all the above items are completed, the Building and Planning Department will authorize power. This authorization will be
faxed to the power company which is the supplier for your address.
DRAINAGE
The home must be provided with adequate drainage to allow the runoff rain water to flow away, not under, the
home. It may require the excavating of a trench to divert to the flow or the installation of a drain. Water that is
allowed to flow under the home will cause rot and mildew and could possibly undermine the piers and cause
sagging and damage to your floors.
DRIVEWAYS
A concrete pipe of at least 15” in diameter must be placed under the driveway at the drainage ditch. This is
required by the Edgefield County Road Ordinance. Any questions regarding this installation should be directed
to the Edgefield County Building & Planning Office (803-637-4073).
E 911 NUMBERS
In order that emergency vehicles can locate your home in the event that you require assistance, you must display
the number assigned to you by the 911 office on your home. If your home cannot be viewed from the road, place
the number at your driveway and on your home.
ELECTRICAL CONNECTIONS
All electrical work must comply with the National Electric Code. You may perform this work yourself or hire a
S.C. licensed electrician. As per the HUD Manual, Sec. 3280.803(k)(3)(i), installation of the meter receptacle on
the side of the home can be done ONLY by the manufacturer.
You will be required to obtain a meter receptacle from the power company or in the case of SCE&G, obtain one
from an approved supplier. All manufactured homes also require a disconnect panel installed at the meter
location. The size of the disconnect is determined by the power requirement of the home, i.e.100, 150 or 200
amp. There are two types of service, overhead and underground. The illustrations attached will assist you in the
installation of these electrical panels.
PLUMBING
All plumbing connections (water, sewer, etc.) must be made in accordance with the International Plumbing Code.
All pipes under the home must be supported by metal strapping at no more than 5 foot intervals, proper slopes
must be maintained to allow drainage on sewer lines. All joints in plastic piping must be glued with an approved
cement for the pipe being used. Green pipe can be glued to either ABS or PVC. All plumbing connections need
to be left uncovered until after inspection.
REGISTRATION DECAL
The decal that will be provided to you at the time you register your home must be placed in a window that faces
the roadway or driveway in order that it can be seen from a vehicle without driving off the road or driveway.
SITE CLEARING
The site under the home must be cleared of all organic materials, grass, roots, stumps, weeds, etc. A plastic vapor
barrier may be installed using 6 mil or better plastic sheeting.
STEPS
All door openings must be equipped with a set of steps with a minimum landing of 36” by 36”. Steps shall not
have a rise of more than 8 1/4” per step. Anywhere a step or landing is 30” or more above the ground, it must be
provided with a handrail at least 30” tall and have vertical pickets spaced to allow no more than a 4” opening.
Wooden steps must be constructed of pressure treated lumber and fastened together with galvanized fasteners. If
the landing/steps are not set into the ground, they must be secured with a ground anchor and strap so that the
landing/step cannot turn over or be pushed over. If masonry steps are used, the blocks or bricks must be mortared
and provided with handrails if required.
Steps & Landing
Handrail height – 34-38”
Measured from nosing of each tread.
Pickets required on handrails when landing
is 30” or more to grade. Pickets must be
spaced 4” apart or less.
Tread: 10 inch minimum Riser: 8 1/4 “ maximum
Steps & landing must be freestanding.
Landing MUST NOT be attached to mobile home.
All exterior doors must have a landing the
width of door x 36” deep
Minimum guardrail
height 36”
If landing is more than
30” above grade, guard-
rails are required.
Threshold of door must
not be more than 8 ¼”
above landing. If door
swings over landing,
threshold must not be
more than 1 ½” above
landing.
4” x 4” pressure
treated posts
HANDRAILS
R311.5.6 Handrails.
Handrails shall be provided on at least one side of each continuous run of treads or flight with four or
more risers.
R311.5.6.1 Height.
Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of
ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm).
R311.5.6.2 Continuity.
Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the
top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned
or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not
less than 1½ inch (38 mm) between the wall and the handrails.
Exceptions:
1. Handrails shall be permitted to be interrupted by a newel post at the turn.
2. The use of a volute, turnout, starting easing or starting newel shall be allowed over the lowest tread.
R311.5.6.3 Handrail grip size.
All required handrails shall be of one of the following types or provide equivalent graspability.
1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 1¼ inches (32
mm) and not greater than 2 inches (51 mm). If the handrail is not circular it shall have a perimeter
dimension of at least 4 inches (102 mm) and not greater than 6¼ inches (160 mm) with a maximum cross
section of dimension of 2¼ inches(57 mm).
2. Type II. Handrails with a perimeter greater than 6¼ inches (160 mm) shall provide a graspable finger
recess area on both sides of the profile. The finger recess shall begin within a distance of ¾ inch (19 mm)
measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 mm)
within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for at
least 3/8 inch (10 mm) to a level that is not less than 1¾ inches (45 mm) below the tallest portion of the
profile. The minimum width of the handrail above the recess shall be 1¼ inches (32 mm) to a maximum
of 2¾inches (70 mm). Edges shall have a minimum radius of 0.01 inch (0.25 mm).
RESTRICTIONS
Pre-1977 MANUFACTURED HOMES
Manufactured homes titled prior to June 1976 does not meet the Housing and Urban Development (HUD)
requirements and cannot be used in Edgefield County without meeting the County ordinance concerning
manufactured homes. You need to contact the Building and Planning Department prior to the purchase of this
home or moving this home to another site.
PENALTIES
Failure to license, register, or obtain proper permitting for a manufactured home located within the
unincorporated areas of Edgefield County shall be punishable as a misdemeanor and subject to a fine not to
exceed $500 per day.
Warning!
Read below before connecting to Service-Entrance Equipment
The electrical system of this home has been designed for a 4-wire feeder system. The grounding system is
isolated from the neutral system. Be sure to connect a separate insulated, green colored conductor to the service
ground in the service-entrance equipment located adjacent to or near the home. All bonding screws, straps or
buses in this main electrical distribution panel as well as on all appliances, have been removed and discarded.
Two ground rods or grounding electrode conductors, 8ft min and 6ft apart are required. Connecting to a 3-wire
system is a violation of the applicable National Electric Code and increases the risk of electrical shock and fire.
PLEASE READ THE FOLLOWING CAREFULLY!
Electrical power will not be authorized until your home is completely installed with all the steps, skirting in place
and all inspections completed and approved. The home must be registered with the Tax Assessor’s Office and
ALL fees paid in full before home is moved to the site. Edgefield County is not responsible for promises made
by dealers and sales people regarding completion in a given time frame. The time for proper installation of a
manufactured home is dependent upon many factors including but not limited to the guidelines in this manual.
Edgefield County’s primary concern is the safety and habitability of all homes placed within the county.
Manufactured homeowners are asked to reinforce this message to the dealerships where they purchase their
homes.
SOUTH CAROLINA MANUFACTURED HOME
INSTALLATION CERTIFICATION
Customer __________________________________________________ Date _________________________
Address Where Home
Is To Be Installed ________________________________________________________________________
Private Property Park
Manufacturer/Year/ Model ___________________________________________________________________
New Pre-Owned Single Section Multi-Section
Serial Number ______________________________________________________________________________
Retail Center _______________________________________ Salesperson __________________________
Licensed Installer _____________________________________ License No. ___________________________
Installer Address ___________________________________________________________________________
Installer Phone _____________________________________
I CERTIFY THAT THE MANUFACTURED HOME HAS BEEN INSTALLED IN ACCORDANCE WITH
THE INSTALLATION GUIDELINES OF THE MANUFACTURER AND THE REGULATIONS
ESTABLISHED BY THE SOUTH CAROLINA MANUFACTURED HOUSING BOARD. SCMHB Regulation
No. 19-425.16B(3)
____________________________________________________ ____________________________________
Licensed Installer Date
______________________________________________________________ _______________ ____________________________
Sales Manager Date
Approved for use by the South Carolina Manufactured Housing Board
Rev.8/97