RecordWell Data

Planning Commission Meeting — Agenda Packet

Lancaster County · Lancaster County · Planning Commission · meeting of Feb 17, 2026 · Agenda packets

Open the original document More from Lancaster County

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Planning Commission Members District 1: Jason Cavalier District 2: Yokima Cureton District 3: Lynette Hinson District 4: Judianna Tinklenberg District 5: Shelly Richards, Chair District 6: Sheila Hinson District 7: Frances Liu County Attorney Ginny L. Merck-Dupont Secretary to Planning Commission Mara Mata Planning Director April Williams February 17, 2026 6:00 PM PLANNING COMMISSION County Council Chambers, County Administration Building, 101 North Main Street, Lancaster, SC 29720 AGENDA 1. Call to Order Regular Meeting 2. Approval of the Agenda 3. Approval of Minutes a. January 20, 2026 Regular Minutes b. February 5, 2026 Workshop Minutes 4. Citizens Comments [Lancaster County welcomes comments and input from citizens. However, because items before the Planning Commission may not move forward to the County Council, citizens are best served speaking during the Public Hearing for each individual item. Please sign up for comments under the Public Hearing Item about which you wish to speak. If you are here to speak on more than one item, please sign up under each item you wish to discuss. The Chair will call your name to speak during the Public Hearing portion of discussion of that item as listed on the agenda.] 5. Public Hearing Items for Recommendations to Council a. CU-2025-2644: Nechyporuk/Fort Mill Hwy Application by Volodymyr Nechyporuk and Thomas Frizzi for a Conditional Use Permit for Unit B at 1081 Fort Mill Hwy (p/o TM # 0006-00-068.01) for a proposed Minor Maintenance & Repair (Auto). 6. Non-Hearing Items a. NRN-2026-0011: New Road Names- February Group February Group Submittal, new road names from E911 Addressing via Preliminary Plats and Civil Plans, pursuant to Sec. 6.4.11 of the Unified Development Ordinance. 7. Status of Items Tabled, Recommended, Deferred, or Held Page 1 of 107 a. SD-2023-0867 Catawba Ridge (Edgewater) Application by ESP Associates and Catawba Ridge Holdings LLC for a preliminary plat for 840 acres north of Great Falls Highway (TMs 0128-00-012.00 & 0126-00- 048.00), for a residential community of 1,438 lots. Applicant has requested indefinite hold while revisions and Traffic Impact Analysis are completed. - b. SD-2023-1869: Barberville Commercial Application by Moody Group/Jan Ringeling on behalf of Barberville Developers LLC and Martin Senior and Associates LLC for a Preliminary Plat for six parcels totaling 10.92 acres located at the northwest corner of Barberville Road and Fort Mill Highway (TM #s 0006-00-057.00, 0006-00-058.00, 0006-00-058.01, 0006-00-058.02, 0006-00- 058.03), in order to create a multi-parcel commercial development with central shared access. 8. Other a. Discussion of Planning Commission's CIP Projects 9. Adjournment Recommendations made at this meeting are tentatively scheduled for consideration by County Council in the following month. County Council agendas are posted online at https://lancastercosc.portal.civicclerk.com/. Anyone requiring special services to attend this meeting should contact 285-1565 at least 24 hours in advance of this meeting. Lancaster County Council agendas are posted at the Lancaster County Administration Building and are available on the Website: https://www.lancastercountysc.gov/ Meetings are livestreamed and can be found by using the following link: https://www.youtube.com/@LancasterCoSCGov/streams Page 2 of 107 Agenda Item Summary Ordinance # / Resolution # : N/A Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Information to Show on Agenda Below Title: Proposal: Property Details: Property Location: Current Zoning District: Proposed Zoning District: Applicant: Council District: Statutory Notices: Proposed Action Advances the Following Comprehensive Plan Guiding Principles: Points to Consider: Recommendation: Attachments: 1. 1-20-2026 Draft Regular Minutes and Attachments Page 3 of 107 MEMBERS OF LANCASTER COUNTY PLANNING COMMISSION JASON CAVALIER , DISTRICT 1 T. YOKIMA CURETON , DISTRICT 2 LYNETTE HINSON , DISTRICT 3 JUDIANNA TINKLENBERG , DISTRICT 4 CHAIR : MICHELLE RICHARDS , DISTRICT 5 SHEILA HINSON , DISTRICT 6 FRANCES LIU, DISTRICT 7 SECRETARY : MARA MATA MINUTES Lancaster County Planning Commission January 20, 2026, 6:00 p.m. Chairman Richards called the meeting to order at 6:04 p.m. 1. Roll Call: Quorum is present (6 Commissioners) Commissioners Present: Jason Cavalier, Dist. 1 Judianna Tinklenberg, Dist. 4 T. Yokima Cureton, District 2 Michelle Richards, Dist. 5 Lynette Hinson, District 3 Sheila Hinson, Dist. 6 Frances Liu, Dist. 7 Absent: Shelia Hinson Staff Present: April Williams, Planning Director Corey Barnes, Planner Matthew Blaszyk, Planner Kirsten Willis, Planner Jennifer Bryan, Planning Technician Mara Mata, Administrative Assistant Ginny Merck-Dupont, County Attorney Josiah Parke, Budget Analyst The following press were notified of the meeting by email in accordance with the Freedom of Information Act: The Lancaster News, Kershaw News Era, The Rock Hill Herald, The Fort Mill Times, Cable News 2, Channel 9, and the local Government Channel. The agenda was also posted in the lobby of the County Administration Building for the required length of time and was published on the County website. Prayer and Pledge of Allegiance………………………………..Yokima Cureton THE FOLLOWING IS A SUMMARY OF PROCEEDINGS. IT IS NOT A VERBATIM TRANSCRIPT. 2. Election of Officers for 2026 Chair yields to Planning Director April Williams to moderate the election of Chair and Vice Chair. a. Moderator calls for nominations for the office of Chair: Page 4 of 107 2 Yokima Cureton nominates Michelle Richards; Second by Judianna Tinklenberg. Moderator asks nominees if they are willing to serve if elected. Michelle Richards is willing. Commissioners chose to elect by a show of hands. Vote: 5:1 in favor. Jason Cavalier Opposed. Michelle Richards is elected as Chair by a simple majority. b. Moderator calls for nominations for the office of Vice-Chair: Michelle Richards nominates Judianna Tinklenberg; Second by Lynette Hinson. Moderator asks nominees if they are willing to serve if elected. Judianna Tinklenbrg is willing. Commissioners chose to elect by a show of hands. Vote: 5:1 in favor. Jason Cavalier Opposed. Judianna Tinklenberg is elected as Vice-Chair by a simple majority. Moderator yields to the new Chair. 3. APPROVE AGENDA Chairman Richards called for a motion to approve the Agenda. Motion to Approve by Y. Cureton; 2nd by J. Tinklenberg. Vote: 6:0 in favor. Motion approved unanimously. 4. APPROVE MINUTES a. November 18, 2025 Regular Minutes (Amended) Chairman Richards called for a motion to approve November 18, 2025 Regular Minutes as written. Motion to Approve by Y. Cureton; 2nd by J. Tinklenberg. Vote: 5:1in favor. Motion approved. Jason Cavalier opposed. Page 5 of 107 3 b. December 16, 2025 Regular Minutes Chairman Richards called for a motion to approve November 18, 2025 Regular Minutes as written. Motion to Approve by J. Cavalier; 2 nd by J. Tinklenberg. April Williams clarified that the December 16th, 2025 minutes were amended with email notice to the Commissioners. Vote: 6:0 in favor. Motion approved unanimously. c. January 08, 2026 Workshop Meeting Minutes Chairman Richards called for a motion to approve January 08, 2026 Workshop Meeting Minutes as written. Motion to Approve by L. Hinson; 2nd by J. Cavalier. Vote: 6:0 in favor. Motion approved unanimously. Chairman Richards summarized the two Citizen’s Comments submitted by email. 5. CITIZEN’S COMMENTS [see Sign-In sheet attached] 1. Jeannine Clifton (Indian Land) shared her concerns regarding the Barberville subdivision plans and advertisements. 2. Alan Sparr (Indian Land) shared his concerns on the C.F. Smith project and the lack of supporting infrastructure. 3. Libby Sweat-Lambert (Van Wyck & Lancaster) shared her concerns on the moratorium restricted area and the lack of supporting infrastructure. 4. Barbara Scannell (Indian Land) urged for the UDO to include a master transportation plan and storm water plan. 6. PUBLIC HEARING ITEMS FOR RECOMMENDATION TO COUNCIL a. RZ-2025-2810 EMS Facility Application by Greg Bass on behalf of Lancaster County for a rezoning of 1.745 acres located at 9070 Van Wyck Rd (TM 0022-00-007.02) from Medium Density Residential (MDR) to Institutional (INS) District, to construct a new EMS Station. Staff Presentation: Kirsten Willis presented the application consistent with the staff report. Staff Recommendations: Approval. Page 6 of 107 4 Questions To staff: Commissioner Cureton and Kirsten Willis discussed whether the town of Van Wyck provided feedback for this EMS Facility. Comment from applicant(s): The applicant did not have any comment or concerns to share. Questions from Commissioners: The Commission had no comments or concerns to share. Public Hearing: (See attachments: Sign-in Sheets) 1. Barbara Scannell (Indian Land) shared a statement regarding her support for this project. Applicant Rebuttal: The applicant did not have any comment or concerns to share. Chairman Richards closed Public hearing and called for a motion on item RZ-2025-2810 EMS Facility. Motion to approve by J. Cavalier; 2 nd by Y. Cureton. Discussion: The Commission had no comments or concerns to share. Called vote: 6:0 in favor. Motion is approved unanimously. The item will be referred to County Council for final decision, and the applicant will be informed of time and date. 7. PUBLIC HEARING ITEMS FOR PLANNING COMMISSION DECISION a. SD-2024-1350 Riverside Single Family aka Riverside Manor Application by Coulston Development on behalf of owners B & C Land Farming LLC for a Preliminary Plat for 251.42 acres at and surrounding 4602 Riverside Road (TM 0028-00-038.00) for a single-family residential development of 133 lots (a/k/a Riverside Single-Family) County Attorney Ginny Merck-Dupont reminded the Commission and Public that this item on the Agenda was brought back by court order. Staff Presentation: Matthew Blaszyk presented the application consistent with the staff report. Staff Recommendations: Approval. Page 7 of 107 5 Questions To Staff: Commissioner Cureton and Staff discussed the previous denial by the Commission. She shared SC Code A&N 6-20-1130 and stated that the Commission has a statutory duty to deny applications that do not comply with adopted standards. April Williams clarified that at this stage, the project does comply with UDO requirements. Later stages will require different standards. Commissioner Tinklenberg and April Williams discussed the court order. Commissioner Tinklenberg stated that she agreed with the Commission’s previous decision. Commissioner Liu and County Attorney Ginny Merck-Dupont discussed the consequences of not abiding by the court order. Commissioner Liu reiterated to the Public that the Planning Commission has been court ordered to approve this project as it meets all requirements for the UDO. Commissioner Cavalier and Matthew Blaszyck confirm that this project meets UDO standards. Commissioner Tinklenberg states, for the record, “I would like the record to please indicate our concerns for safety. I would also like for the record to indicate the need to update our UDO to include a street buffer yard and the definition of through lots.” Chairman Richards reminds the Commission that this is not the final design, SCDOT will complete another review in later stage. [The following conversation was requested to be on record by Commissioner Liu] Commissioner Liu directed a question towards Staff: “And I-may I make one more-well I think I know the answer to this, but I would like clarification for myself and all the residents of the county. If all the requirements of the UDO are met and the schools that would be affected by this neighborhood are overcrowded and absolutely to capacity, we cannot consider that. Is that correct?” Matthew Blaszyck: “Since the county currently does not have concurrency standards in the UDO, that is correct.” Commissioner Liu: “So, for everyone who asks why we approve things when the schools are bursting at the seams, under South Carolina law, we cannot consider that as a factor in turning a neighborhood down. Is that correct?” Matthew Blaszyck agreed. [End of verbatim conversation] Page 8 of 107 6 Commissioner Cureton stated, for the record, “I would love to have concurrency consideration on the records for a UDO update.” April Williams replied that due to current legislation, she should advocate for concurrency to her council members. Comment from applicant(s): Earl Coulston (Indian Land) explained that at the previous hearing for Riverside, the Commission had asked for two turning lanes. He agreed to add one and was denied. He reiterated that this project meets all UDO requirements, and after meeting with DOT, they agreed that turning lanes were not required at this time. Questions from Commissioners: Commissioner Liu asked the applicant if he understood the Commission’s concerns. Earl Coulston replied that he appreciates the Commission concerns. Commissioner Cavalier and Earl Coulston discussed the possibility of adding one turn lane. Earl Coulston stated he would consider it, he also stated the buffer for these homes will be around 100 feet from the road. Commissioner Cureton and Earl Coulston discussed his children and where they live. Public Hearing: (See attachments: Sign-in Sheets) 1. Barbara Scannell (Indian Land) shared her concerns over dangerous traffic near Sun City and urges the inclusion of plans for operational impacts in the UDO. Applicant Rebuttal: The applicant did not have any comment or concerns to share. Chairman Richards closed Public hearing and called for a motion on item SD-2024-1350 Riverside Single Family aka Riverside Manor. Motion to approve by J. Cavalier; 2 nd by Y. Cureton. Discussion: The Commission had no comments or concerns to share. Roll called vote: 4:2 in favor. Motion is approved. Jason Cavalier For Yokima Cureton Against Lynette Hinson For Judianna Tinklenberg Against Michelle Richards For Francis Liu For The Planning Commission has final approval of Sub-Divisions. Page 9 of 107 7 8. CAPITAL IMPROVEMENT PLAN Presentation a. Information pertaining to the Capital Improvement Plan ("CIP") process, as well as instructions on suggesting new capital projects for consideration by County Council for inclusion in the ten-year Capital Improvement Plan. Staff Presentation: Josiah Parke presented the CIP via PowerPoint and reviewed the submittal form with the Commission. Questions To Staff: Josiah Parke explained that the CI Projects is used to create a thriving community, build and maintain that infrastructure to deliver public services. Commissioner Cureton and April Williams discussed the process of proposing and vetting projects from the Commission. The Commission and Staff discussed the possibility of changing the process and deadline. The projects will now be proposed by the Commission before February 5 th to allow for discussion at the February workshop and voted on in the regular February meeting. The full list of the County’s proposed projects will be presented to the Commission on April 21 st, 2026. Staff will send out a list of last year’s projects for the Commissioner’s to compare with their proposals, along with information of projects that had another source of funding. 9. Status of Items Tabled, Recommitted, Deferred or Held a. SD-2023-0867 Catawba Ridge (Edgewater) Application by ESP Associates and Catawba Ridge Holdings LLC for a preliminary plat for 840 acres north of Great Falls Highway (TMs 0128-00-012.00 & 0126-00-048.00), for a residential community of 1,438 lots. The applicant has requested indefinite hold while revisions and Traffic Impact Analysis are completed. 10. Other a. Commissioner Liu stated to the Public that all Public Comments are given to the Commission. b. Commissioner Cureton stated that cooperation from other entities is needed to make better decisions for the County. Chairman Richards replied that will need time and it is a process. 9. ADJOURN Motion to adjourn by Y. Cureton; 2nd by L. Hinson. Motion approved by unanimous consent. Meeting adjourned at 7:28 p.m. Page 10 of 107 ATTACHMENT: Sign-In Sheets Page 11 of 107 Page 12 of 107 Page 13 of 107 Page 14 of 107 ATTACHMENT: Email Public Comments Page 15 of 107 Page 16 of 107 Page 17 of 107 ATTACHMENT: Document Provided by Jeannine Clifton For General Comments Page 18 of 107 Page 19 of 107 Page 20 of 107 ATTACHMENT: Document Provided by Barbara Scannell For Item 6a Page 21 of 107 Page 22 of 107 ATTACHMENT: Capital Improvement Plan PPT Page 23 of 107 2022-2031 Capital Improvement Plan (CIP) FY27 Budget Cycle January 20, 2026 1 Page 24 of 107 • Recap: 2022-2031 CIP and Timeline • Review the Planning Commission’s role in the CIP amendment process • Provide instructions for submitting new CIP projects to the Planning Department for consideration by Council AGENDA 2 Page 25 of 107 Create a thriving community Build and maintain infrastructure to deliver public services Residents Council County Staff 10-year plan: Revised annually No monetary commitment Budget Implications Borrow (G.O. Bond) Tax and Fees (Millage Rate and Impact Fee) Cash (Savings) Capital Planning WHY WHO WHAT HOW 3 Page 26 of 107 CIP Summary • A financial planning tool only • Assets or projects of $100K or more • Various Funding Sources: • Capital Project Sales Tax – Special Revenue Tax • General Fund Millage • Impact Fees • Fund Balance • Borrow (Ex: General Obligation Bond) 4 Page 27 of 107 Annual CIP Timeline • January - New this year, the Planning Commission submits projects for consideration by Council for the CIP • February - March – Planning staff review the Planning Commission’s CIP projects, and Finance presents a list of capital projects to the Planning Commission • March - April - Planning Commission ranks, votes on, and recommends a prioritized list of capital projects for Council consideration • April - Early May - County Administrator reviews and recommends a prioritized list of capital projects to Council for consideration • June - Council adopts a revision to the current CIP as part of the budget process for the new fiscal year 5 Page 28 of 107 CIP Process Steps Review existing CIP capital projects, and future capital needs Departments submit capital project request Finance receives, reviews, and compiles capital project requests Planning Commission reviews, suggests, ranks, and recommends capital projects Administrator reviews, ranks and recommends capital projects Council adopts CIP via ordinance Council Adoption of Annual Budget including Capital On-going project management Planning Developing Monitoring & Reporting 6 Page 29 of 107 7 Page 30 of 107 New for FY27 • Planning Commission members will submit suggested capital project additions to the County’s Capital Improvement Plan for Council consideration • These additions must be submitted to Planning staff for development using the Capital Project Google Request Form by Thursday, February 5 • Planning Commissioners will research, price, and submit formalized projects for theranking exercise in March along with other new or unfunded projects provided by County staff 8 Page 31 of 107 For Take - Away Staff asks you to do the following: • Formulate and submit new CIP project requests to the Planning Director for the Capital Improvement Plan, using the Google Form, by close of business on February 5th 9 Page 32 of 107 Recap - Calendar Dates • January 20 Meeting - Receive information on project submittal process • February 5 - Submit new CIP projects to the Planning Director via Google form • February 20th Meeting - Discuss and narrow project submittals to at most five project requests with Planning Staff • March 17 - Prioritize and rank PC capital project requests • April 21 - Vote and recommend to Council a prioritized list of all unfunded capital projects for revision to the currently adopted CIP 10 Page 33 of 107 Questions Questions 11 Page 34 of 107 Agenda Item Summary Ordinance # / Resolution # : N/A Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Information to Show on Agenda Below Title: Proposal: Property Details: Property Location: Current Zoning District: Proposed Zoning District: Applicant: Council District: Statutory Notices: Proposed Action Advances the Following Comprehensive Plan Guiding Principles: Points to Consider: Recommendation: Attachments: 1. 2-5-2026 Draft Workshop Minutes and Attachments Page 35 of 107 MEMBERS OF LANCASTER COUNTY PLANNING COMMISSION JASON CAVALIER , DISTRICT 1 T. YOKIMA CURETON , DISTRICT 2 LYNETTE HINSON , DISTRICT 3 JUDIANNA TINKLENBERG , DISTRICT 4 CHAIR : MICHELLE RICHARDS , DISTRICT 5 SHEILA HINSON , DISTRICT 6 FRANCES LIU, DISTRICT 7 SECRETARY : MARA MATA MINUTES OF THE LANCASTER COUNTY PLANNING COMMISSION WORKSHOP MEETING February 5, 2026 5:00 P.M. MINUTES Chairman Richards called the meeting to order at 5:06 p.m. 1. Roll Call: Commissioners Present: Jason Cavalier, Dist. 1 Judianna Tinklenberg, Dist. 4 T. Yokima Cureton, District 2 Michelle Richards, Dist. 5 Lynette Hinson, District 3 Sheila Hinson, Dist. 6 Frances Liu, Dist. 7 Absent: Sheila Hinson, Lynette Hinson Staff Present: April Williams, Planning Director Corey Barnes, Planner Matthew Blaszyk, Planner Kirsten Willis, Planner Jennifer Bryan, Planning Technician Mara Mata; Admin Asst The following press were notified of the meeting by email in accordance with the Freedom of Information Act: The Lancaster News, Kershaw News Era, The Rock Hill Herald, The Fort Mill Times, Cable News 2, Channel 9, and the local Government Channel. 2. New Business a. CU-2025-2644: Nechyporuk/Fort Mill Hwy Application by Volodymyr Nechyporuk and Thomas Frizzi for a Conditional Use Permit for Unit B at 1081 Fort Mill Hwy (p/o TM # 0006-00-068.01) for a proposed Minor Maintenance & Repair (Auto). Staff Presentation: Kirsten Willis Discussion: • Building was already outfitted for use, but Conditional Use permits are for the person, not the building, and he is a new tenant • No Public Comments submitted regarding permit Page 36 of 107 2 b. SD-2023-1869 Barberville Commercial Application by Moody Group/Jan Ringeling on behalf of Barberville Developers LLC and Martin Senior and Associates LLC for a Preliminary Plat for six parcels totaling 10.92 acres located at the northwest corner of Barberville Road and Fort Mill Highway (TM #s 0006-00-057.00, 0006-00-058.00, 0006-00-058.01, 0006-00-058.02, 0006-00- 058.03), in order to create a multi-parcel commercial development with central shared access. Staff Presentation: April Williams Discussion: • Possible deferral • Prior General Comments at PC meetings regarding this item • County met with Public to hear concerns • By-Right Development • Mixed-Use vs. Mix of Uses • Why item is back on Agenda • Previous application included 1 minor and 1 major subdivision • Site plan remains the same • UDO Requirements • Role of Planning Department • 6-29-1150 State Code requires all submitted applications to be reviewed • Procedural explanation of Planning Commission’s recommendations • Minor subdivisions are reviewed internally • Why the original minor subdivision plan was allowed to move forward • BMPs location and maintenance • Violations • Buffers on Highway • Community feedback • Why minor is allowed to be combined into Major • UDO wording regarding Minor sub-divisions • Explanation of Plat map c. NRN-2026-0011 New Road names – February Group February Group Submittal, new road names from E911 Addressing via Preliminary Plats and Civil Plans, pursuant to Sec. 6.4.11 of the Unified Development Ordinance. Staff Presentation: Jennifer Bryan Discussion: The Commission had no questions or concerns to share. Page 37 of 107 3 3. Other: a. Proposals for CIP Projects • Submission Process • Discussion on two proposed projects • Review Process for CIP Submission in April 2026 b. Code Enforcement 4. Adjourn Meeting was adjourned at 6:08 PM. Page 38 of 107 Page 39 of 107 Page 40 of 107 Page 41 of 107 Page 42 of 107 Page 43 of 107 Page 44 of 107 Page 45 of 107 Page 46 of 107 Page 47 of 107 Page 48 of 107 Page 49 of 107 Page 50 of 107 Page 51 of 107 Page 52 of 107 Page 53 of 107 Page 54 of 107 Agenda Item Summary Ordinance # / Resolution # : Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Council Action Requested: Refer to Council for one hearing Strategic Plan Focus Alignment: Points to Consider: Funding and Liability Factors: Recommendation: Attachments: 1. CU Nechyporuk Map Frame 2. CU Staff Report Final 3. CU Application 4. ConditionalUsePlan_639045883789854059 5. ConditionalUsePlanpage3_639045883789854059 6. NotApprovedLetter_TRC Review 7. CU Procedure Reqts 8. App UDO Provisions 9. Deed 1824_336 10. Use Chart p. 29 Page 55 of 107 Proposal: Conditional Use: Minor Maintenance/Repair (Auto) Subject Property Catawba River Reid Pointe Development Overlook at Barber Rock Page 56 of 107 Case: CU-2025-2644 Staff Report to Planning Commission Meeting Date: February 17, 2026 Proposal: Conditional Use Application for Automotive Minor Service Shop Property Location: TM# 0006-00-068.01 on Fort Mill Highway (Hwy. 160) Current Zoning: General Business (GB) Applicant: Volodymyr Nechyporuk Council District: District 4, Jose Luis Statutory Notes: Published Hearing Notice The Lancaster News 01/31/26 Posted Signs 01/29/26 Mailed Notices 01/30/26 Agenda Published and posted in Lobby 02/10/26 Overview & Background Site.Information The subject property is located at 1081 Fort Mill Highway, Unit B , in the Panhandle area of District 4 and is identified as Tax Parcel ID 0006-00-068.01. The parcel contains approximately 2.1 acres and is zoned General Business (GB). The applicant is requesting approval of Conditional Use to allow minor auto repair services on the site. The property is currently developed for this use, as identified in the application, and features prefabricated garage bays for automotive work Page 57 of 107 Case: CU-2025-2644 Staff Report to Planning Commission Meeting Date: February 17, 2026 Findings & Analysis Project.Proposal The applicant is seeking a conditional use permit for a “Minor Maintenance/Repair” (p. 29, 2022 UDO) vehicle services shop. This application is submitted by a prospective tenant of a pre- existing, multi-tenant structure that was built to accommodate service type business via garage bay setup. Vehicle Services – Minor are defined as, “facilities for the fueling, cleaning, and servicing of automobiles, recreational vehicles, and other personal vehicles, as primary use. Examples include: gas stations, car washes, car stereo and alarm installers, detailing services, muffler and radiator shops, battery sales and installation, and quick-lube service” (p. 361, 2022 UDO). Technical.Review.Committee.(TRC) All reviewers have approved the request. The Zoning Department issued a conditional approval, which does not require an additional review, but notes that while no issues were found with the proposed use, an upfit permit will be required for the installation of the lift. All other commentary included in the review is attached to this report via the “TRC Comment Letter. ” This request was routed to LCWSD and SCDOT for review as well. Both agencies responded with “No Review Needed, ” noting that the structure is pre-existing and that the request pertains solely to a review of the proposed use. No physical modifications affecting utilities or access are being proposed. Page 58 of 107 Case: CU-2025-2644 Staff Report to Planning Commission Meeting Date: February 17, 2026 Summary.of.Surrounding.Zoning.™ .Uses The chart above provides the abbreviated districts, and surrounding uses. The aerial zoning map provided below illustrates the surrounding zoning districts. Comprehensive.Plan The subject parcel lies in the “Growth Area” Future Land Use designation of the 2040 Comprehensive Plan. This designation is, “intended.to.designate.areas.where.growth.should.occur. based.on.the.availability.of.supportive.infrastructure.and.land¡.These.areas.are.intended.to. support.suburban.scale.residential.development.along.with.supportive.commercial.development. at.major.crossroads.and.along.arterial.streets.and.thoroughfares¡.Supportive.infrastructure. required.to.provide.development.includes.adequate.roadways? .water.and.sewer.availability? . school.capacity? .emergency.services? .and.similar.services‹ (p.34, 2040 Comp. Plan). The proposed use aligns with this FLU designation, as well as the General Business zoning. Jurisdiction Zoning District Use North Lancaster County GB / NB / MDR Undeveloped / Residential South Lancaster County MX Undeveloped East Lancaster County GB / MDR Undeveloped / Non-Conforming Residential West Lancaster County GB Undeveloped Page 59 of 107 Case: CU-2025-2644 Staff Report to Planning Commission Meeting Date: February 17, 2026 Site.Pictures ..Entrance.to.Facility.from.Hw y¡.7❷ 6 ................. Front.Façade .of.Fac ility.from.Hw y¡.7❷ 6 Public Safety Fire District: Indian.Land? .F DID.8❺ 876 Fire Station Location: 7❹ ❶ .Six.Mile.Creek.Road.Lancaster? .SC.8❺ ❸ 86 EMS District: EMS.Station.0.― .❺ EMS Station Location: ❺ ❶ ❸ ❷ .Old.Bailes.Road? .Indian.Land.8❺ ❸ 7❶ Lancaster County Sheriff’s Office District: District.7 Applicable UDO Provisions: ❶ ¡7¡8.CONDITIONAL.USE.(CU) A. Conditional Uses are uses which are generally compatible with other land uses permitted in a zoning district but which, because of their unique characteristics or potential impacts on the surrounding neighborhood and/or the County as a whole, require individual consideration in their location, design, configuration, and/or operation at the particular location proposed. B. All Conditional Uses shall at a minimum meet the standards for the zoning district in which they are located and the specific standards set forth in this article for that use. C. Individual consideration of the use may also call for the imposition of individualized conditions in order to ensure that the use is appropriate at a particular location and to ensure protection of the public health, safety, and welfare. Page 60 of 107 Case: CU-2025-2644 Staff Report to Planning Commission Meeting Date: February 17, 2026 D. Approval procedures for Conditional Use permits are found in Chapter 9 Administration. Per.Chapter.❶ ¡❹ ¡❷ ? .Minor.Vehicle.Service.uses.have.additional.applicable.requirements.that.are. specific.to.such.use¡.Those.requirements.are.detailed.in.Chapter.❶ .(p¡.79❹‗79❺ ? .8688.UDO).and. report.is.attached.to.confirm.code.requirements.have.been.met¡.(Applicable.UDO.Provisions) Additional UDO Provisions: Conditional.Use.Application.Procedures.are.detailed.in.Chapter.❺.of.the.current.UDO.(p¡.98❸ ? .8688. UDO).and.report.is.attached.to.confirm.procedural.requirements.have.been.met¡.(Conditional.Use. Procedure.Requirements)¡ Staff Recommendation Staff recommend approval of this conditional use application. Attachments: 1. Location/Zoning Map 2. Conditional Use Application 3. TRC Comment Letter 4. Conditional Use Procedure Requirements 5. Applicable UDO Provisions 6. 2022 UDO Use Type Chart (p. 29) Staff Contact: Kirsten Willis, Planner kwillis@lancastercountysc.gov 803-285-6005 Page 61 of 107 I Lancaster Plannln1 Department ? South Carolina County P.O. Box 1809, 101 N. Main Street, Lancaster, SC 29721 !11'!!!!!!!!!!!!!!111!!!!:~ Phone: 803.285.6005, plannlng@lancastercountysc.gov - www.mylancastersc.org CONDITIONAL USE APPLICATION SUBMITTAL REQUIREMENTS • Completed Application • Signatures of Applicant and Property Owner • All items noted on the Conditional Use Plan Checklist • Fees associated with review GENERAL INFORMATION Property Address 1081 Fort Mill Highway Unit B City Fort Mill State SC Zip 29707 Tax Parcel ID 000600068.01 Current Zoning G-eo ere...\ bu.!.t,r~~~ent Use o?Cia: I k.0:> ~ "-I: Total Acres A, ) Surrounding Property Description Wowlc.J C<ea Proposed Conditional Use auto repair services CONTACT INFORMATION Applicant Name Volodymyr Nechyporuk Address 11711 Hawick Valley Ln City Charlotte state NC Zip 28277 Phone 704-654-0735 Email willtanllc@gmail.com Prope~Own~r Name Thomas Frizzi Address j 0'6::£> GI C,,,(h s-t: City })~ StateN r. Zip 2-¥03.b Phone 980-721-1839 Email toptf21@gmail.com January 2025 1 Page 62 of 107 APPLICATION CERTIFICATIONS I hereby certify that I have read this appllcatlon and the Information supplied herein is true and correct to the best of my knowledge. I agree to comply With all appllcable County ordinances and state laws related to the use and development of the land. I further certify that I am the property owner, or his/her authorized agent, or the subject property. I understand that falsifying any Information herein may result in reje~hls request. -f J.../ 'I/ et. > Applicant Date Property Owner(s) Date Additional Owner (s) Attach owner's notarized written authorization with property information if the applicant is not the owner. SCHEDULE/PROCESS 1. Submit Application • The deadline for this application is at least 45 days prior to the Planning Commission meeting, held every third Tuesday of the month. • Once an application is submitted, it is placed on the Planning Commission agenda for the following month. • An application withdrawal should be made in writing and received prior to public notice in order to receive a refund. • Conditional Use Application Fee -$500.00 2. Planning Commission • Conducts a public hearing on the application to receive input from Lancaster County citizens, applicant, and other interested parties. • Reviews the application to ensure it is consistent with the Lancaster County Unified Development Ordinance, Comprehensive Plan, and all adopted County plans. • Makes a recommendation to the County Council. 3. County Council • Approves, denies, or submits application to the Planning Commission for further study. • Action requires a resolution for approval. • Subsequent to County Council action, notice of action will be provided to the applicant, January 2025 3 Page 63 of 107 SITE OF REPAIRS EXISTING LANDSCAPE ISLANDS. NO CHANGES REQUIRED EXISTING HARD SURFACE UNMARKED PARKING SPACES TO RECEIVE NEW WHEEL STOPS EXISTING HARD SURFACE DRIVE NO CHANGES REQUIRED This drawing and prints are the property of Reddric k Architecture. The reproduction, copying or other use of this draw ing without written consent from Reddrick Architecture is not permitted, except as permitted by the copyright or architectural work s by the US Copy Right Act. Copyright Architectural Seals Project Name Drawing Credits draftsman checker architect Revisions Sheet Title Editable electronic files are available for an addi tional costs. Please contact the architect for those files. Editable ele ctronic files are available for reference only and discrepancy betwee n sealed drawings and editable electronic files shall be reported to the owner and architect for resolution. Digital Plans James Reddrick Architect www.jr-architect.online 980.254.5348 james@jr-architect.online 1333 Rising Oak Dr, Charlotte, NC, 28206 LLC 5/14/25 5/14/2025 10:12:51 PM A0.1 Author Warehouse Repairs 2025-1081 Cover Sheet Author Author James Reddrick Architect www.jr-architect.online james@jr-architect.online 980.254.5348 LLC ARCHITECTURE Sheet List Sheet Number Sheet Name Current Revision Designer A0.1 Cover Sheet 2 A1.0 Code Summary 2 A1.1 Site Plan and Life Safety Plan 2 Grand total: 3 WAREHOUSE REPAIRS N 12" = 1'-0" A0.1 1 Vicnity Map N 12" = 1'-0" A0.1 3 Existing Landscaping Island 1 RENDERING IS FOR ILLUSTRATION OF THE EXISTING CONDITIONS ON THE SITE. ALL CONDITIONS ARE EXISTING. EXCEPT AS NOTED IN RED. THE GREEN AREAS ARE EXISTING LANDSCAPING. NO CHANGES ARE REQUIRED. THE WHITE IS EXISTING HARD SURFACE. NO CHANGES ARE REQUIRED. SEE OTHER SHEETS FOR FURTHER DETAILS 1 2 No. Description Date 0 Issue for Construction 3/25/25 1 Permit Revisions 4/19/25 2 Permit Revisions 5/14/25 Page 64 of 107 4'-0" MIN TO B.O. BRAILLE 60" MAX TO B.O. HIGHEST TACTILE CHARACTER 9" 4'-0" MIN TO B.O. BRAILLE 60" MAX TO B.O. HIGHEST TACTILE CHARACTER EXIT ACCESSIBILITY TACTILE EXIT SIGN RESTROOM SIGN ALL BUILDINGS ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. ALL SIGNAGE SHALL CONFORM WITH ADA ACCESSIBILITY GUIDELINES: 1. LETTERS & NUMERALS MUST BE RAISED 1__ 32 " FROM SIGN SURFACE. 2. CHARACTER HEIGHT MUST BE AT LEAST 5/8" BUT NOT EXCEED 2". 3. TYPE STYLE FOR LETTERS AND NUMBERS SHALL BE SANS SERIF OR SIMPLE SERIF. 4. WORDS AND NUMBERS MUST BE CONVERTED INTO GRADE 2 BRAILLE, AND BE APPLIED TO SIGN. 5. PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW PICTOGRAM. 6. SEE SHEET G-004 FOR MORE DETAILED SIGNAGE INFORMATION. LEVER HANDLE CRYSTAL ICE, FROSTED ACRYLIC ADA SIGN, 9"x9" MOUNTED ON 1/16" BRUSHED ALUM-LOOK ACRYLIC, 1/32" RAISED BLACK LETTERING CLEAR BRAILLE STAINLESS STEEL STANDOFFS G.C. TO INSTALL AS REQ'D BY GOV. CODES/ COORDINATE WITH TENANT FOR ANY ADDITIONAL SIGNS FROM EDGE OF DOOR FRAME TO CL OF SIGN 1 1_ 4 " TO 1 1/2" 11/2" ANCHOR PLATES ARE 12 GAUGE STEEL AND 6" WIDE. (LENGTH VARIES). FURNISHED WITH STAINLESS STEEL MACHINE SCREWS TO ACCOMMODATE WALL FINISHES TO 1 1/2" THICK. ANCHOR PLATES SECURED TO STUDS BY WELDING, WIRING OR SELF THREADING SCREWS. GRAB BARS LOCATE GRAB BARS ON EACH SIDE, OR ONE SIDE AND THE BACK, OF THE WATER CLOSET, 33 INCHES ABOVE AND PARALLEL TO THE FLOOR. GRAB BARS AT THE SIDE ARE TO BE AT LEAST 42 INCHES LONG WITH THE FRONT END POSITIONED 12 INCHES IN FRONT OF THE WATER CLOSET. GRAB BARS AT THE BACK CAN NOT BE LESS THAN 36 INCHES LONG. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACE IS REQUIRED TO BE 1 1/4 TO 1 1/2 INCHES, OR THE SHAPE IS TO PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS IS TO BE 1 1/2 INCHES. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. GRAB BARS AND ANY SURFACE ADJACENT TO THEM CAN NOT HAVE ANY SHARP OR ABRASIVE ELEMENTS. EDGES ARE TO HAVE A MINIMUM RADIUS OF 1/8 INCH. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAX. BENDING MOMENT FROM THE APPLICATION OF A 250 LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT. SHEAR STRESS INDUCED IN A GRAB BAR BY THE APPLICATION OF 250 LBF POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SEAR STRESS. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A 250 LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250 LB. POINT LOAD, PLUS THE MAX. MOMENT FROM THE APPLICATION OF A 250 LB. POINT LOAD, SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE. GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". CORRESPONDING GRADE II BRAILLE EXISTING BRACKET MOUNTED FIRE EXTINGUISHER TO BE 2A:10BC EXTINGUISHER WITH 5LB CAPACITY. INSTALLED AT EACH EXIT DOOR. 4' - 0" GRAB BARS SOAP DISPENSER 1' - 6" 3' - 0" 3' - 0" 0' - 6 1/2" 2' - 10" 3' - 4" 3' - 0" 3' - 6" 3' - 7" MIRROR TOILET TISSUE DISPENSER GRAB BARS 1' - 5 1/4" 4' - 0" 0' - 6" 3' - 5" 3' - 6 1/4" 1' - 6" 1' - 6" 3' - 6" TOP OF GRAB BAR 3' - 0" PROVIDE GRAB BARS FOR WATER CLOSETS THAT WERE REPLACED REPLACEMENT OF SINK DONE IN A MANNER THAT MAINTAINED THE LEVEL OF ACCESSIBLITY PER SOUTH CAROLINA EXISTING BUILDING CODE SECTION 401.2; THUS SINK DOES NOT HAVE TO COMPLY WITH CURRENT ACCESSIBILITY REQUIREMENTS SOAP DISPENSER PAPER TOWEL DISPENSER WASTE RECEPTACLE 18" VERTICAL GRAB BAR 42" GRAB BAR 36" GRAB BAR TOILET TISSUE DISPENSER ACCESSIBLE RESTROOM SIGN MIRROR PT DISPENSOR (PTD) AND WASTE RECEPTACLE (WR) 4' - 0" This drawing and prints are the property of Reddric k Architecture. The reproduction, copying or other use of this draw ing without written consent from Reddrick Architecture is not permitted, except as permitted by the copyright or architectural work s by the US Copy Right Act. Copyright Architectural Seals Project Name Drawing Credits draftsman checker architect Revisions Sheet Title Editable electronic files are available for an addi tional costs. Please contact the architect for those files. Editable ele ctronic files are available for reference only and discrepancy betwee n sealed drawings and editable electronic files shall be reported to the owner and architect for resolution. Digital Plans James Reddrick Architect www.jr-architect.online 980.254.5348 james@jr-architect.online 1333 Rising Oak Dr, Charlotte, NC, 28206 LLC 5/14/25 5/14/2025 10:12:51 PM A1.0 Author Warehouse Repairs 2025-1081 Code Summary Author Author . _________ _________ _________ psf _________ psf _________ psf _________ _________ mph (ASCE-7) DESIGN LOADS: Importance Factors: Ground Snow Load: Live Loads: Wind Load: Exposure Category: Ultimate Wind Speed: _________ psf Snow Seismic Mezzanine Roof Floor ALLOWABLE Building Height in Stories (T504.4) Building Height in Feet (T504.3) TELEPHONE # NAME LICENSE # 2021 SOUTH CAROLINA BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS S1Ss _________ %g Dual w/Special Moment Frame Inverted Pendulum _________ %g Dual w/Intermediate R/C or Special Steel Site Classification: (ASCE 7) Risk Category: (Table 1604.5) Analysis Procedure: Basic structural system (check one) LATERAL DESIGN CONTROL: SOIL BEARING CAPACITIES: Spectral Response Acceleration: Moment Frame Building Frame Bearing Wall Architectural, Mechanical, Components anchored? Simplified Equivalent Lateral Force Dynami c TOTAL # # OF ACCESSIBLE SPACES PROVIDED ACCESSIBLE PROVIDED VAN SPACES WITH REGULAR WITH 5' ACCESS AISLE PROVIDED LOT OR PARKING AREA ZONED GB TOTAL # OF PARKING SPACES REQUIRED DETAIL # AND SHEET # REQ'D FIRE SEPARATION DISTANCE (FEET) RATING** Structural frame, including columns, girders, and trusses BUILDING ELEMENT Exterior East North Bearing walls Interior Nonbearing walls and partitions (see section 601-602 if rated) South West Smoke Partition Party/ Fire Wall Separation Corridor Separation Shaft enclosures - Other Shaft enclosures - Exit Tenant/ Dwelling Unit/ Sleeping Unit Separation Smoke Barrier Separation Floor construction Including supporting beams and joists A-5A-4A-3A-2A-1 Factory FIRM DESIGNER Architectural Electrical Civil Fire Alarm Mechanical Plumbing Structural Retaining Walls >5' High Sprinkler-Standpipe Primary Occupancy Classification(s): Business Assembly Educational CONTACT: The required type of construction for the building shall be determined by applying the height and area limitations for each of the applicable occupancies to the entire building. The most restr ictive type of construction, so determined, shall a pply to the entire building. Separated use (508.4) See below for area calculations for each story, the area of the occupancy shall be such that the sum o f the ratios of the actual floor area of each use divided by the allowable floor area for ea ch use shall not exceed 1. Non-Separated Use (508.3.) Actual Area of Occupancy A Allowable Area of Occupancy A ________________________ a. Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F) b. Total Building Parameter = ______________ (P) c. Ratio (F/P) = __________ (F/P) d. W = Minimum width of public way = ________________ (W) e. Percent of frontage increase I = 100[F/P - 0.25] X w/30 = ________ (%) Unlimited area applicable under conditions of Sections 507. Frontage area increases from Section 506.3 are computed thus: 2 1 STORY NO DESCRIPTION AND USE Mixed Occupancy No f Actual Area of Occupancy B Allowable Area of Occupancy B _____________________ (A) BLDG AREA PER STORY (ACTUAL) + + + < 1 < 1.00 ______ Exception: _______ Separation: _____ Hr. Yes 0.97 = Maximum Building Area=total number of stories in the building x D (506.2). Maximum of 3. 3 The Maximum area of open parking garage shall be permitted to comply with 406.5.4. 4 Incidental use Separation DCB Historical Data Presumptive Field Test ASEISMIC DESIGN CATEGORY: PARKING: 2021 SC BUILDING CODE Shell/Core- Contact the local inspection jurisdiction for possible additional procedures and requirements First time interior completion (upfit) New Building Addition Constructed: (date) III-B III-A Wet III NFPA 13D II-A II I Class: Yes Yes NFPA 13 II-B NFPA 13R Yes Dry I-AConstruction Type: (Check all that Apply) No No Sprinklers: I-B No Fire District: Standpipes: IV V-B V-A PARTIAL Emergency Lighting: Carbon Monoxide Detection: Smoke Detection Systems: Exit Signs: Fire Alarm: Yes Yes Yes Yes Yes No No No No No Partial 0 0 0 0 0 0 0 0 0 0 0 0 (980) 254-5348 James Reddrick James Reddrick Architect LLC 10'< X >30' NA N/A N/A N/A N/A N/A - - - - - - - - - - - psf (Net) - psf N/A N/A N/A 8135 (B) TABLE 506.2 AREA 4 (C) AREA FOR FRONTAGE INCREASE 1,5 (D) ALLOWABLE AREA PER STORY OR UNLIMITED 2,3 SHOWN ON PLANS CODE REFERENCE PROVIDED W/ ___________* REDUCTION DESIGN # FOR RATED ASSEMBLY DESIGN # FOR RATED PENETRATION DESIGN # FOR RATED JOINTS Roof construction Including supporting beams and joists *Indicate section number permitting reduction. Field Test (provide copy of test report as a refere nced document): Presumptive Bearing capacity Pile size, type, and capacity N/A N/A N/A N/A N/A N/A N/A N/A IV III II I Data Source: DCBA E F No Yes Wind Earthquake (Reproduce the following data on the building plans sheet 1 or 2) E-MAIL James@jr-architect.online Yes No Flood Hazard Area: ALLOWABLE AREA I-4 54 I-3 2 3 I-2 1 I-1Institutional I-3 Condition B E F-1 Moderate F-2 Low H-1 Detonate H-2 Deflagrate Hazardous H-3 Combust H-4 Health H-5 HPM MMercantile R-4R-3R-2R-1Residential S-2 Low S-1 Moderate Storage High-piled Enclosed Parking Garage Repair Garage Open UUtility and Miscellaneaous Accessory Occupancy Classifications FIRE PROTECTION REQUIREMENTS N/A PERCENTAGE OF WALL OPENING CALCULATIONS DEGREE OF OPENINGS PROTECTION (TABLE 705.8) ALLOWABLE AREA (%) ACTUAL SHOWN ON PLANS (%) FIRE SEPARATION DISTANCE (FEET) FROM PROPERTY LINES LIFE SAFETY SYSTEM REQUIREMENTS LIFE SAFETY PLAN REQUIREMENTS Fire and/ or smoke rated wall locations (Chapter 7) Assumed and real property line locations (if not on the site plan) Exterior wall opening area with respect to distance to assumed property lines (705.8) Occupancy Use for each area as it relates to occupa nt load calculation (Table 1004.1.2) Occupant loads for each area Exit access travel distances (1017) Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.4) Clear exit widths for each exit door Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3) Actual occupant load for each exit door A separate schematic plan indication where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separation Location of doors with panic hardware (1010.1.10) Location of doors with delayed egress locks and the amount of delay (1010.1.9.7) Location of doors with electromagnetic egress locks (1010.1.9.9) Location of doors equipped with hold-open devices Location of emergency escape windows (1030) The square footage of each fire area (202) The square footage of each smoke compartment (407.5 ) Note any code exceptions or table notes that may have ben utilized regarding the items above ACCESSIBLE DWELLING UNITS (SECTION 1107) NOT APPLICABLE TOTAL UNITS ACCESSIBLE UNITS REQUIRED ACCESSIBLE UNITS PROVIDED TYPE A UNITS REQUIRED TYPE A UNITS PROVIDED TYPE B UNITS REQUIRED TYPE B UNITS PROVIDED TOTAL ACCESSIBLE UNITS PROVIDED ACCESSIBLE PARKING (SECTION 1106) 132" ACCESS AISLE 8' ACCESS AISLE Walls X>30 Other Renovation Phased Construction - Shell/Core- Contact the local inspection jurisdiction for possible additoinal procedures and requirements 2021 SC EXISTING BUILDING CODE Prescriptive Repair Chapter 14 Level I Level II Level III Historic Property Change of Use RISK CATEGORY (T1604.5) Current: I II Proposed: III IV I II III IV Special Inspections: Yes (Contact the local inspection jurisdiction fo r additional procedures and requirements) No BASIC BUILDING DATA GROSS BUILDING AREA TABLE BUSINESS (LESS THAN 10% OF FLOOR AREA) Incidental Uses (T509) N/A Special Uses (Ch 4- List Code) N/A Special Provisions (Ch 5 - List Code) N/A Frontage increase is basedon the unsprinklered area value in T506.2 5 ALLOWABLE HEIGHT 2 3 Provide code reference if the "Shown on Plans" quantity is not based on T504.3 or 504.4. 1 The maximum height of air traffic control towers must comply with T412.3.1. 2 The maximum height of open parking garages must comply with T406.5.4. 3 Floor Ceiling/Roof Ceiling Assembly Columns Supporting Floors/ Roof Occupancy/ Fire Barrier Separation ACCESSIBLE REGULAR DRINKING FOUNTAINS LAVATORIES URINALS OCCUPANCY USE GROUP AND/OR SPACE DESIGNATION WATERCLOSETS M Existing PLUMBING FIXTURE REQUIREMENTS (T2902.1) SHOWER/ TUBS Special Approvals (Local Jurisdiction, Department of Insurance. OSC, DPI, DHHS, ICC, etc.,describe below) SPECIAL APPROVALS (If applicable to project) - - - - - - - - - - - - - - - - - - - - - - - - - - ENERGY REQUIREMENTS: The following data shall be considered minimum and a ny special attribute required to meet the energy code shall also be provided. Each Designer shall furnish the required portions of the project information for the plan data sheet. If performance method, state the annual energy cost for the standard reference design vs annual energy cost for the proposed design. THERMAL ENVELOPE: (Prescriptive method only) Roof/ceiling Assembly(each assembly) Description of assembly U-Value of total assembly R-Value of insulation Skylights in each assembly U-Value of skylight Total percentage of skylights in each assembly: Exterior Walls (each assembly) Description of assembly U-Value of total assembly R-Value of insulation Openings (windows or doors with glazing) U-Value of assembly Solar heat gain coefficient: Projection factor Low E required, if applicable Door U-Values Walls below grade (each assembly) Description of assembly U-Value of total assembly R-Value of insulation Floors over unconditioned space (each assembly) Description of assembly U-Value of total assembly R-Value of insulation Floors slab on grade Description of assembly U-Value of total assembly R-Value of insulation Horizontal/vertical requirement Slab heated Climate Zone: Existing building envelope complies with code: Yes (The remainder of this section is not applicab le) No Exempt Building: Yes (Provide code or stautory reference) See Note 1 Below. No 4A 3A 5A Method of Compliance: Energy Code ASHRAE 90.1 (2013) Other Performance Prescriptive Performance Prescriptive - - (I ) S (I ) E 2,000 N/A Exterior East North Interior South West (EXCEPT 1 AND 2 FAMILY DWELLINGS AND TOWNHOUSES) N/A N/A N/A Owner or Authorized Agent: Code Enforcement Jurisdiction: Owned By: Name of Project: Address: County City City/County Private State State Warehouse Repairs 1081 Fort Mill Highway, Fort Mill, SC 29707 (980) 254-5348 Buildings descriptions and scope of work: JAMES REDDRICK Lancaster james@jr-architect.online PROJECT INFORMATION: Phone # E-Mail N/A N/A N/A N/A N/A N/A N/A Repaired: (date) Current Occuapncy(s) Ch. 3 Proposed Occuapncy(s) Ch. 3 DATA 1978 2024 S-2, S-1, F-2 EXISTING (SQ. FT.) FLOOR - - - 22,102 NEW (SQ. FT.) Warehouse - - - 0 0 0 0 Warehouse 14,696 (S-2) low hazard 26,000 N/A 26,000 55'-0" 3 12'-6" 1 (EXISTING) T504.3 T504.4 STRUCTURAL DESIGN (EXISTING-NO CHANGES REQUIRED ) N/A SC The existing warehouse repair work was performed prior to issue of permit. The AHJ stopped work and requested the owner hire an architect. The owner hired JR-Architect. JR-Architect evaluated the facility and determined the repair work included replacing broken toilet fixtures, replacing paint, replacing broken doors, and replacing floor finishes. The repair work included Suites A, B, C, D, and E. The facility was evaluated for code compliance and the architectural drawings show compliance for permitting purposes and documentation. Suite D already has permit from 2010 and thus no work required in Suite D. N/A N/A N/A N/A N/A N/A PER ZONING 18 1 3 - 1 10 MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT Winter dry bulb -°F Thermal Zone -- Summer dry/wet bulb -°F DB / -°F WB Winter dry bulb -°F Interior Design Conditions Summer dry bulb -°F Relative Humidity -% Outside Air Heating Load - MBH Outside Air Cooling Load - MBH Mechanical Space Conditioning System Description of Unit - Heating Efficiency - Cooling Efficiency - Unitary Heat output of Unit - Cooling output of Unit - Size category.. If oversized state reason. N/A Boiler Size category. If oversized state reason. N/A Chiller List Equipment Efficiencies . Performance Prescriptive Method of Compliance: ELECTRICAL SYSTEM AND EQUIPMENT Lighting Schedule (each fixture type) Number of Lamps in fixture - Ballast type used in the fixture - Number of Ballasts in fixture - Total wattage per fixture - Total interior wattage specified vs allowed Lamp type required in fixture - Energy Code: Performance Prescriptive ASHRAE 90.1: Additional Required Prescreptive Compliance C406.2 More Efficient HVAC Equipment Performance C406.3 Reduced Lighting Power Density C406.4 Enhanced Digital Lighting Controls C406.5 On-Site Renewable Energy C406.6 Dedicated Outdoor Air System C406.7 Reduced Energy Use in Service Water Heating N/A REPAIR (SQ. FT.) Replace doors, floors, paint, toilets 0 0 0 0 0 UP, Sprinklered No limit 2 - F Unisex New Required - 7 1 - 10- 5 0 M F Unisex - - 7 - - 5 (EXISTING-NO CHANGES REQUIRED) Note 1: 2018 NC Existing building code section 811. 1 does not require existing building envelopes to comply with the ener gy code (EXISTING-NO CHANGES REQUIRED) (EXISTING-NO CHANGES REQUIRED) (EXISTING-NO CHANGES REQUIRED) 1. NO CHANGES ARE REQUIRED TO EXISTING PLUMBING FIXTURE COUNT. 2. EACH TENANT SPACE HAS LESS THAN 15 PEOPLE THUS DR INKING FOUNTAINS ARE NOT REQUIRED PER SC PLUMBING CODE SECTION 410.2. HOWEVER SUITE D HAS MORE THAN 15 PEOPLE BUT SUITE HAS AN EXISTING REFRIGERATOR AND EXISTING BREAK ROOM SINK FOR OCCUPANTS TO DRINK WATER N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10'< X >30' 10'< X >30' 0 0 0 N/A 0 0 N/A N/A N/A 0 N/A 48 Assembly (EXISTING-NO CHANGES REQUIRED) (EXISTING-NO CHANGES REQUIRED) (EXISTING- NO CHANGES REQUIRED) 1 10'< X >30' N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A S-2, S-1, F-2 2* _____________________ +14,696 (S-2) 26,000 (S-2) 2,512 (S-1) 17,500 (S-1) 4,898 (F-2) 18,000 (F-2) Warehouse (SUITE A) 2,512 (S-1) mod hazard 17,500 N/A 17,500 * S-1 adjacent to S-2 is 2hr rating. However F-2 adjacent to S-2 does not require a fire rating. Warehouse 4,898 (F-2) low hazard 18,000 N/A 18,000 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 1/4" = 1'-0" A1.0 1 Accessibility Restroom and Exit Sign 6" = 1'-0" A1.0 2 Tactile Exit Sign 3/8" = 1'-0" A1.0 3 Fire Extinguisher Cabinet 3/8" = 1'-0" A1.0 4 Water Closet Front Elevation 3/8" = 1'-0" A1.0 5 Water Closet Side Elevation 3/8" = 1'-0" A1.0 A1.1 6 Typical Accessible Restroom 3/8" = 1'-0" A1.0 7 Paper Towel Dispenser 3" = 1'-0" A1.0 8 Grab Bar Details 12" = 1'-0" A1.0 9 Accessible Parking Standard 1 1 1 2 2 No. Description Date 0 Issue for Construction 3/25/25 1 Permit Revisions 4/19/25 2 Permit Revisions 5/14/25 Page 65 of 107 MIDLAND CART COMPANY A100 OFFICE A101 BATH A102 VACANT STORAGE B100 OFFICE B101 BATH B102 VACANT STORAGE C100 OFFICE C101 BATH C102 OFFICE D102 OFFICE D103 BREAK D104 BATH D105 BATH D106 BATH D107 TOP TURF E100 OFFICE E101 BATH E102 JAN E103 SHOWER E104 SECURE STORAGE E105 Room Legend BATH BREAK Closet JAN MIDLAND CART COMPANY OFFICE SECURE STORAGE SHOWER SOUND DESIGN SOUND DESIGN STORAGE TOP TURF VACANT STORAGE FORT MILL HIGHWAY 49' - 9 1/2" RECENTLY NEW TENANT 50' - 7" 97' - 0" EXISTING TENANT SINCE 2010 96' - 6 1/2" EXISTING TENANT SINCE 2010 83' - 0" RECENTLY NEW TENANT 60' - 3" Closet E106 OFFICE D101 SOUND DESIGN STORAGE D100A SOUND DESIGN D100B S-2 OCCUPANCY 98' - 0" EXISTING WALL TO BE COVERED WITH NEW 2HR FIRE BARRIER SHAFT WALL PER UL U417. CONTINUITY AT HEAD AND JAMB OF WALL SHALL BE EQUAL TO UL DESIGN CJ -D-004 PROVIDE 36" REAR GRAB BAR PROVIDE 42" SIDE GRAB BAR PROVIDE 18" VERTICAL GRAB BAR AT WATER CLOSETS PROVIDE 36" REAR GRAB BAR PROVIDE 42" SIDE GRAB BAR PROVIDE 18" VERTICAL GRAB BAR AT WATER CLOSET SEE ACCESSIBLE NOTE 4&5 RIGID FIBERLGASS SHEETS ARE CLASS 1 COMMODITY. IT IS STORED IN PILES ON 4 ’X4 ’ PALLETS. NON -COMBUSTIBLE STORAGE ITEMS ONLY RIGID FIBERLGASS SHEETS LIGHT MANUFACTURING EXISTING ELECTRIC CART STORAGE. CHARGING STATION IS NOT REQUIRED OR PROVIDED SOUND DESIGN IS EXISTING TENANT SPACE WITH PERMIT. NO CHANGES REQUIRED. SPACE SHOWN FOR DOCUMENTATION ONLY. DOCK EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED SIDE YARD SETBACK 15' - 0" SIDE YARD SETBACK 15' - 0" FRONT YARD SETBACK 50' - 0" REAR YARD SETBACK 15' - 0" EXISTING BUILDING ENCROACHES INTO SETBACK. POSSIBLY BUILT PRIOR TO THE ADOPTION OF THE CURRENT ZONING ORDINANCE; THUS IT IS LEGAL NON - CONFORMING AND GRANDFATHERED TO ALLOW ENCROACHMENT INTO SETBACK. BUILDING BUILT IN 1978. EXISTING FORK LIFT DRIVE APRON FOR COILING DOORS EXISTING BUILDING ENCROACHES INTO SETBACK. POSSIBLY BUILT PRIOR TO THE ADOPTION OF THE CURRENT ZONING ORDINANCE; THUS IT IS LEGAL NON - CONFORMING AND GRANDFATHERED TO ALLOW ENCROACHMENT INTO SETBACK. BUILDING BUILT IN 1978. A1.0 6 FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER EXIT DISTANCE IS 70FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 360 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 72" AREA IS S -1 OCCUPANCY. OCCUPANT LOAD CALCULATION 2512 SQFT / 500 SQFT PERSON = 5 PERSON AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 4949 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 90 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 90 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS F -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 10 PERSON ACTUAL OCCUPANT LOAD (1004.5 EXCEPTION) 4,906 SQFT EXIT DISTANCE IS 80 FT OCCUPANT LOAD AT EACH DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 4848 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 100FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 45 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 5000 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 67 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 60 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" 7' - 6" OUTDOOR STORAGE OF PROPANE TANKS IN AN APPROVED STORAGE CABINET. SCREENED BY 6FFT TALL WOOD FENCE. EXISTING LANDSCAPING ISLAND 5FT WALK WAY EXISTING COMPACTED HARD SURFACE TO BE TREATED WITH "GRAVEL LOK" . SEE ACCESSIBLE NOTE 1 8' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" EXISTING LANDSCAPING ISLAND 19' - 0" 19' - 0" 23' - 0 1/2" 19' - 0" 1' - 9 1/2" 6' - 6" TYPICAL WHEEL STOP LOCATION. SEE WHEEL STOP NOTE 1&2 SEE ACCESSIBLE NOTE 2&3 EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING HARD SURFACE TO REMAIN NO CHANGES REQUIRED EXISTING HARD SURFACE TO REMAIN NO CHANGES REQUIRED 30' - 0" 32' - 0" EXISTING SEPTIC EXISTING SEPTIC EXISTING SEPTIC 12' - 0" 10' - 0" CANOPY 18' - 0" 5' - 0" 5' - 0" 23' - 8 3/4" EXISTING DUMPSTER 6' HEIGHT 6FT OPAQUE WOOD FENCE WITH WOOD GATE DOORS 6FT HIGH WOOD FENCE 20' - 0" 11' - 10 1/2" UNMARKED HARD SURFACE PARKING SPACES TO GET NEW WHEEL STOPS, TYPICAL SEE ACCESSIBLE NOTE 4&5 23' - 2 3/4" UNMARKED HARD SURFACE PARKING SPACES TO GET NEW WHEEL STOPS, TYPICAL EXISTING WELL 5' - 0" 9' - 0" 5' - 0" 5' - 0 1/4" 9' - 0" This drawing and prints are the property of Reddric k Architecture. The reproduction, copying or other use of this draw ing without written consent from Reddrick Architecture is not permitted, except as permitted by the copyright or architectural work s by the US Copy Right Act. Copyright Architectural Seals Project Name Drawing Credits draftsman checker architect Revisions Sheet Title Editable electronic files are available for an addi tional costs. Please contact the architect for those files. Editable ele ctronic files are available for reference only and discrepancy betwee n sealed drawings and editable electronic files shall be reported to the owner and architect for resolution. Digital Plans James Reddrick Architect www.jr-architect.online 980.254.5348 james@jr-architect.online 1333 Rising Oak Dr, Charlotte, NC, 28206 LLC 5/14/25 5/14/2025 10:12:53 PM A1.1 J.Reddrick Warehouse Repairs 2025-1081 Site Plan and Life Safety Plan J.Reddrick J.Reddrick 3/32" = 1'-0" A1.1 2 Site and Life Safety Plan OWNER FORT MILL HIGHWAY LLC PHYSICAL ADDRESS 1081 FORT MILL HWY ACRES 1.91 ACRES PID 0006 -00 -068.01 UNIFIED DEVELOPMENT ORDINANCE ZONING CLASSIFICATION GENERAL BUSINESS (GB) PERMITTED USES LIGHT MANUFACTURING (TABLE 2.5.3) OUTDOOR STORAGE WAREHOUSE INDOOR STORAGE BUSINESS SUPPORT SERVICES PARKING REQUIREMENTS 1 SPACE PER 500 SQFT OF OFFICE SPACE (TABLE 7.2.4) PARKING CALCULATIONS: MIDLAND GOLF CART OFFICE SALE 231 SQFT/250 SQFT = 1 PARKING SPACE MIDLAND STORAGE AREA DOES NOT REQUIRE PARKING VACANT STORAGE -B OFFICE 231 SQFT/500 SQFT = 1 PARKING SPACE VACANT STORAGE -B STORAGE AREA DOES NOT REQUIRE PARKING VACANT STORAGE -C OFFICE 231 SQFT/500 SQFT = 1 PARKING SPACE VACANG STORAGE -C STORAGE AREA DOES NOT REQUIRE PARKING SOUND DESIGN OFFICE 500 SQFT/500SQFT = 1 PARKING SPACE SOUND DESIGN STORAGE AREA DOES NOT REQUIRE PARKING TOP TURF OFFICE 279 SQFT/500 SQFT = 1 PARKING SPACE TOP TURF STORAE AREA DOES NOT REQUIRE PARKING TOTAL PARKING SPACES REQUIRED = 5 PARKING SPACES OR AS INDICATED BY ZONING OFFICIALS TOTAL ACCESSIBLE SPACES REQUIRED = 1 VAN ACCESSIBLE SPACE TOTAL EXISTING PARKING SPACE PROVIDED = 15 EXISTING PARKING SPACES (PROVIDE NEW WHEEL STOPS) TOTAL ACCESSIBLE PARKING SPACES PROVIDED = 1 VAN ACCESSIBLE SPACE + 2 ACCESSIBLE SPACE TOTAL SPACES = 18 PARKING SPACES SETBACKS 50FT FRONT YARD TABLE 2.4 15FT SIDE YARD 15FT REAR YARD N STORAGE NOTES FOR SUITE E 1. RX FERTILIZER ACCUBLEND PELLET FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS 2. PRIME TIME TURF TYPE TALL FESCUE BLEND GRASS SEED IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS 3. NUTRITE UREA FRILL AGRICULTURAL GRADE 46 -0-0 PELLET FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS. 4. GATOR EXCEL IRON LIQUID FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 275 GALLON TOTE ON PALLETS. 5. DIMENSION 2EW HERBICIDE IS A IRRITANT MATERIAL (NOT TOXIC). IT IS STORED IN 30 GALLON DRUM. MAQ NOT TO EXCEED 125 GALLONS INSIDE BUILDING. 6. PROPANE GAS CYLINDERS IS A FLAMMABLE GAS. IT IS STORED IN 8 GALLON CYLINDERS. MAQ NOT TO EXCEED 300 GALLONS. TANKS TO BE STORED OUTSIDE IN AN APPROVED STORAGE CABINET EQUAL TO USA SAFETY PRODUCT " 4 PROPANE TANKS (33 LB) - OUTDOOR - HORIZONTAL STORAGE - STEEL & MESH - GAS CYLINDER CAGE" GENERAL NOTES 1. ALL CONDITIONS ARE EXISTNG UNLESS NOTED OTHERWISE 2. WORK INCLUDES A. PROVIDING ACCESSIBLE PARKING SPACE, B. GRAB BARS AT RESTROOM SUITES A, B, C, AND E C. ADDING A 2HR FIRE BARRIER TO SEPARATE S -2 SPACE FROM S -1 SPACE BETWEEN SUITE A AND SUITE B D. PROVIDE MANUAL FIRE EXTINGUISHERS AT ALL SUITES E. PROVIDING EVALUATION AND DOCUMENTATION OF CURRENT FACILITY PLAN STORAGE F. EXISTING BATH FACILITIES ARE REPLACEMENT OF FIXTURES DONE IN A MANNER THAT MAINTAINED THE LEVEL OF ACCESSIBLITY PER SOUTH CAROLINA EXISTING BUILDING CODE SECTION 401.2; THUS FIXTURES DOES NOT HAVE TO COMPLY WITH CURRENT ACCESSIBILITY REQUIREMENTS. HOWEVER GRAB BARS ARE ADDED. 3. LIFE SAFETY TRAVEL DISTANCE SHALL NOT EXCEED 200FT TO AN EXIT. SEE PLAN FOR ACTUAL TRAVEL DISTANCE. 4. AT EACH EXIT DOOR PROVIDE A TACTILE EXIT SIGN 5. AT EACH SUITE A FIRE EXTINGUISHER TO BE PROVIDED 6. ALL EXISTING EXIT DOORS SHALL ALLOW FREE EGRESS. 7. ALL GRAVEL DRIVEWAYS/PARKING, SIDEWALKS, AND LANDSCAPING ARE EXISTING. NO GRADING IS REQUIRED. 8. NEW ITEMS INCLUDE "GRAVEL LOK" TREATMENT AT EXISTING GRAVEL WALKWAY. SEE PLAN FOR LOCATION. 9. NEW ITEMS INCLUDE NEW WHEEL STOPS 10. NEW ITEMS INCLUDE NEW ACCESSIBLE PARKING SIGNAGE 1 1 1 ACCESSIBLE PARKING NOTES: 1. COMPACT EXISTING GRAVEL, TREAT ACCESSIBLE AISLE, AND 5FT ACCESSIBLE ROUTE IDENTIFIED WITH "GRAVEL LOK" WHICH IS COMPLIANT WITH ADA REQUIREMENTS FOR HARD NON -SLIP SURFACES. SEE PLANS FOR CLARITY ON WHERE TO PROVIDE "GRAVEL LOK" TO EXISTING HARD SURFACE 2. PROVIDE NEW POLE MOUNTED OR BUILDING MOUNTED VAN ACCESSIBLE PARKING SIGNAGE 3. PAINT VAN ACCESSIBLE AISLE AT EXISTING GRAVEL AREA TREATED WITH "GRAVEL LOK". AND PAINT ACCESSIBLE SYMBOL AT PARKING SPACE 4. PROVIDE NEW POLE MOUNTED OR BUILDING MOUNTED ACCESSIBLE PARKING SIGNAGE 5. PAINT ACCESSIBLE AISLE AT EXISTING HARD SURFACE AREA AND PAINT ACCESSIBLE SYMBOL AT PARKING SPACE 1 WHEEL STOP NOTES: 1. SEE PLAN FOR LOCATION OF NEW WHEEL STOPS. WHEEL ST OP SHALL BE EQUAL OR BETTER THAN 6FT PLASTIC GRAY WHEEL STOP MODEL NO. H -2309GR 72X6X3 BY MANUFACTURER ULINE. INSTALL 3 QTY #4 REINFORCING BARS TO ANCHOR. EMBED AT LEAST 18". 2. SEE PLAN FOR UNMARKED GRAVEL PARKING SPACES TO LOCATE NEW WHEEL STOPS 1 1 1 1 1 1 ALL CONDITIONS ARE EXISTING. EXCEPT AS NOTED IN RED. THE GREEN AREAS ARE EXISTING LANDSCAPING. NO CHANGES ARE REQUIRED. GRADING IS NOT REQUIRED. THE WHITE IS EXSTING HARD SURFACE. NO CHANGES ARE REQUIRED. 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 No. Description Date 0 Issue for Construction 3/25/25 1 Permit Revisions 4/19/25 2 Permit Revisions 5/14/25 Page 66 of 107 MIDLAND CART COMPANY A100 OFFICE A101 BATH A102 VACANT STORAGE B100 OFFICE B101 BATH B102 VACANT STORAGE C100 OFFICE C101 BATH C102 OFFICE D102 OFFICE D103 BREAK D104 BATH D105 BATH D106 BATH D107 TOP TURF E100 OFFICE E101 BATH E102 JAN E103 SHOWER E104 SECURE STORAGE E105 Room Legend BATH BREAK Closet JAN MIDLAND CART COMPANY OFFICE SECURE STORAGE SHOWER SOUND DESIGN SOUND DESIGN STORAGE TOP TURF VACANT STORAGE FORT MILL HIGHWAY 49' - 9 1/2" RECENTLY NEW TENANT 50' - 7" 97' - 0" EXISTING TENANT SINCE 2010 96' - 6 1/2" EXISTING TENANT SINCE 2010 83' - 0" RECENTLY NEW TENANT 60' - 3" Closet E106 OFFICE D101 SOUND DESIGN STORAGE D100A SOUND DESIGN D100B S-2 OCCUPANCY 98' - 0" EXISTING WALL TO BE COVERED WITH NEW 2HR FIRE BARRIER SHAFT WALL PER UL U417. CONTINUITY AT HEAD AND JAMB OF WALL SHALL BE EQUAL TO UL DESIGN CJ -D-004 PROVIDE 36" REAR GRAB BAR PROVIDE 42" SIDE GRAB BAR PROVIDE 18" VERTICAL GRAB BAR AT WATER CLOSETS PROVIDE 36" REAR GRAB BAR PROVIDE 42" SIDE GRAB BAR PROVIDE 18" VERTICAL GRAB BAR AT WATER CLOSET SEE ACCESSIBLE NOTE 4&5 RIGID FIBERLGASS SHEETS ARE CLASS 1 COMMODITY. IT IS STORED IN PILES ON 4 ’X4 ’ PALLETS. NON -COMBUSTIBLE STORAGE ITEMS ONLY RIGID FIBERLGASS SHEETS LIGHT MANUFACTURING EXISTING ELECTRIC CART STORAGE. CHARGING STATION IS NOT REQUIRED OR PROVIDED SOUND DESIGN IS EXISTING TENANT SPACE WITH PERMIT. NO CHANGES REQUIRED. SPACE SHOWN FOR DOCUMENTATION ONLY. DOCK EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED SIDE YARD SETBACK 15' - 0" SIDE YARD SETBACK 15' - 0" FRONT YARD SETBACK 50' - 0" REAR YARD SETBACK 15' - 0" EXISTING BUILDING ENCROACHES INTO SETBACK. POSSIBLY BUILT PRIOR TO THE ADOPTION OF THE CURRENT ZONING ORDINANCE; THUS IT IS LEGAL NON - CONFORMING AND GRANDFATHERED TO ALLOW ENCROACHMENT INTO SETBACK. BUILDING BUILT IN 1978. EXISTING FORK LIFT DRIVE APRON FOR COILING DOORS EXISTING BUILDING ENCROACHES INTO SETBACK. POSSIBLY BUILT PRIOR TO THE ADOPTION OF THE CURRENT ZONING ORDINANCE; THUS IT IS LEGAL NON - CONFORMING AND GRANDFATHERED TO ALLOW ENCROACHMENT INTO SETBACK. BUILDING BUILT IN 1978. A1.0 6 FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER EXIT DISTANCE IS 70FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 360 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 72" AREA IS S -1 OCCUPANCY. OCCUPANT LOAD CALCULATION 2512 SQFT / 500 SQFT PERSON = 5 PERSON AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 4949 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 90 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 90 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS F -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 10 PERSON ACTUAL OCCUPANT LOAD (1004.5 EXCEPTION) 4,906 SQFT EXIT DISTANCE IS 80 FT OCCUPANT LOAD AT EACH DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 4848 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 100FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 45 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" AREA IS S -2 OCCUPANCY. OCCUPANT LOAD CALCULATION 5000 SQFT / 500 SQFT PERSON = 10 PERSON EXIT DISTANCE IS 67 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" EXIT DISTANCE IS 60 FT OCCUPANT LOAD AT DOOR IS 5 PEOPLE: THE DOOR CAPACITY IS 170 PEOPLE THE WIDTH FACTOR IS 0.2 PEOPLE PER INCH THE EXISTING DOOR WIDTH IS 36" 7' - 6" OUTDOOR STORAGE OF PROPANE TANKS IN AN APPROVED STORAGE CABINET. SCREENED BY 6FFT TALL WOOD FENCE. EXISTING LANDSCAPING ISLAND 5FT WALK WAY EXISTING COMPACTED HARD SURFACE TO BE TREATED WITH "GRAVEL LOK" . SEE ACCESSIBLE NOTE 1 8' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" EXISTING LANDSCAPING ISLAND 19' - 0" 19' - 0" 23' - 0 1/2" 19' - 0" 1' - 9 1/2" 6' - 6" TYPICAL WHEEL STOP LOCATION. SEE WHEEL STOP NOTE 1&2 SEE ACCESSIBLE NOTE 2&3 EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING LANDSCAPING TO REMAIN NO CHANGES REQUIRED EXISTING HARD SURFACE TO REMAIN NO CHANGES REQUIRED EXISTING HARD SURFACE TO REMAIN NO CHANGES REQUIRED 30' - 0" 32' - 0" EXISTING SEPTIC EXISTING SEPTIC EXISTING SEPTIC 12' - 0" 10' - 0" CANOPY 18' - 0" 5' - 0" 5' - 0" 23' - 8 3/4" EXISTING DUMPSTER 6' HEIGHT 6FT OPAQUE WOOD FENCE WITH WOOD GATE DOORS 6FT HIGH WOOD FENCE 20' - 0" 11' - 10 1/2" UNMARKED HARD SURFACE PARKING SPACES TO GET NEW WHEEL STOPS, TYPICAL SEE ACCESSIBLE NOTE 4&5 23' - 2 3/4" UNMARKED HARD SURFACE PARKING SPACES TO GET NEW WHEEL STOPS, TYPICAL EXISTING WELL 5' - 0" 9' - 0" 5' - 0" 5' - 0 1/4" 9' - 0" This drawing and prints are the property of Reddric k Architecture. The reproduction, copying or other use of this draw ing without written consent from Reddrick Architecture is not permitted, except as permitted by the copyright or architectural work s by the US Copy Right Act. Copyright Architectural Seals Project Name Drawing Credits draftsman checker architect Revisions Sheet Title Editable electronic files are available for an addi tional costs. Please contact the architect for those files. Editable ele ctronic files are available for reference only and discrepancy betwee n sealed drawings and editable electronic files shall be reported to the owner and architect for resolution. Digital Plans James Reddrick Architect www.jr-architect.online 980.254.5348 james@jr-architect.online 1333 Rising Oak Dr, Charlotte, NC, 28206 LLC 5/14/25 5/14/2025 10:12:53 PM A1.1 J.Reddrick Warehouse Repairs 2025-1081 Site Plan and Life Safety Plan J.Reddrick J.Reddrick 3/32" = 1'-0" A1.1 2 Site and Life Safety Plan OWNER FORT MILL HIGHWAY LLC PHYSICAL ADDRESS 1081 FORT MILL HWY ACRES 1.91 ACRES PID 0006 -00 -068.01 UNIFIED DEVELOPMENT ORDINANCE ZONING CLASSIFICATION GENERAL BUSINESS (GB) PERMITTED USES LIGHT MANUFACTURING (TABLE 2.5.3) OUTDOOR STORAGE WAREHOUSE INDOOR STORAGE BUSINESS SUPPORT SERVICES PARKING REQUIREMENTS 1 SPACE PER 500 SQFT OF OFFICE SPACE (TABLE 7.2.4) PARKING CALCULATIONS: MIDLAND GOLF CART OFFICE SALE 231 SQFT/250 SQFT = 1 PARKING SPACE MIDLAND STORAGE AREA DOES NOT REQUIRE PARKING VACANT STORAGE -B OFFICE 231 SQFT/500 SQFT = 1 PARKING SPACE VACANT STORAGE -B STORAGE AREA DOES NOT REQUIRE PARKING VACANT STORAGE -C OFFICE 231 SQFT/500 SQFT = 1 PARKING SPACE VACANG STORAGE -C STORAGE AREA DOES NOT REQUIRE PARKING SOUND DESIGN OFFICE 500 SQFT/500SQFT = 1 PARKING SPACE SOUND DESIGN STORAGE AREA DOES NOT REQUIRE PARKING TOP TURF OFFICE 279 SQFT/500 SQFT = 1 PARKING SPACE TOP TURF STORAE AREA DOES NOT REQUIRE PARKING TOTAL PARKING SPACES REQUIRED = 5 PARKING SPACES OR AS INDICATED BY ZONING OFFICIALS TOTAL ACCESSIBLE SPACES REQUIRED = 1 VAN ACCESSIBLE SPACE TOTAL EXISTING PARKING SPACE PROVIDED = 15 EXISTING PARKING SPACES (PROVIDE NEW WHEEL STOPS) TOTAL ACCESSIBLE PARKING SPACES PROVIDED = 1 VAN ACCESSIBLE SPACE + 2 ACCESSIBLE SPACE TOTAL SPACES = 18 PARKING SPACES SETBACKS 50FT FRONT YARD TABLE 2.4 15FT SIDE YARD 15FT REAR YARD N STORAGE NOTES FOR SUITE E 1. RX FERTILIZER ACCUBLEND PELLET FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS 2. PRIME TIME TURF TYPE TALL FESCUE BLEND GRASS SEED IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS 3. NUTRITE UREA FRILL AGRICULTURAL GRADE 46 -0-0 PELLET FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 50LB BAGS ON PALLETS. 4. GATOR EXCEL IRON LIQUID FERTILIZER IS A CLASS 1 COMMODITY. IT IS STORED IN 275 GALLON TOTE ON PALLETS. 5. DIMENSION 2EW HERBICIDE IS A IRRITANT MATERIAL (NOT TOXIC). IT IS STORED IN 30 GALLON DRUM. MAQ NOT TO EXCEED 125 GALLONS INSIDE BUILDING. 6. PROPANE GAS CYLINDERS IS A FLAMMABLE GAS. IT IS STORED IN 8 GALLON CYLINDERS. MAQ NOT TO EXCEED 300 GALLONS. TANKS TO BE STORED OUTSIDE IN AN APPROVED STORAGE CABINET EQUAL TO USA SAFETY PRODUCT " 4 PROPANE TANKS (33 LB) - OUTDOOR - HORIZONTAL STORAGE - STEEL & MESH - GAS CYLINDER CAGE" GENERAL NOTES 1. ALL CONDITIONS ARE EXISTNG UNLESS NOTED OTHERWISE 2. WORK INCLUDES A. PROVIDING ACCESSIBLE PARKING SPACE, B. GRAB BARS AT RESTROOM SUITES A, B, C, AND E C. ADDING A 2HR FIRE BARRIER TO SEPARATE S -2 SPACE FROM S -1 SPACE BETWEEN SUITE A AND SUITE B D. PROVIDE MANUAL FIRE EXTINGUISHERS AT ALL SUITES E. PROVIDING EVALUATION AND DOCUMENTATION OF CURRENT FACILITY PLAN STORAGE F. EXISTING BATH FACILITIES ARE REPLACEMENT OF FIXTURES DONE IN A MANNER THAT MAINTAINED THE LEVEL OF ACCESSIBLITY PER SOUTH CAROLINA EXISTING BUILDING CODE SECTION 401.2; THUS FIXTURES DOES NOT HAVE TO COMPLY WITH CURRENT ACCESSIBILITY REQUIREMENTS. HOWEVER GRAB BARS ARE ADDED. 3. LIFE SAFETY TRAVEL DISTANCE SHALL NOT EXCEED 200FT TO AN EXIT. SEE PLAN FOR ACTUAL TRAVEL DISTANCE. 4. AT EACH EXIT DOOR PROVIDE A TACTILE EXIT SIGN 5. AT EACH SUITE A FIRE EXTINGUISHER TO BE PROVIDED 6. ALL EXISTING EXIT DOORS SHALL ALLOW FREE EGRESS. 7. ALL GRAVEL DRIVEWAYS/PARKING, SIDEWALKS, AND LANDSCAPING ARE EXISTING. NO GRADING IS REQUIRED. 8. NEW ITEMS INCLUDE "GRAVEL LOK" TREATMENT AT EXISTING GRAVEL WALKWAY. SEE PLAN FOR LOCATION. 9. NEW ITEMS INCLUDE NEW WHEEL STOPS 10. NEW ITEMS INCLUDE NEW ACCESSIBLE PARKING SIGNAGE 1 1 1 ACCESSIBLE PARKING NOTES: 1. COMPACT EXISTING GRAVEL, TREAT ACCESSIBLE AISLE, AND 5FT ACCESSIBLE ROUTE IDENTIFIED WITH "GRAVEL LOK" WHICH IS COMPLIANT WITH ADA REQUIREMENTS FOR HARD NON -SLIP SURFACES. SEE PLANS FOR CLARITY ON WHERE TO PROVIDE "GRAVEL LOK" TO EXISTING HARD SURFACE 2. PROVIDE NEW POLE MOUNTED OR BUILDING MOUNTED VAN ACCESSIBLE PARKING SIGNAGE 3. PAINT VAN ACCESSIBLE AISLE AT EXISTING GRAVEL AREA TREATED WITH "GRAVEL LOK". AND PAINT ACCESSIBLE SYMBOL AT PARKING SPACE 4. PROVIDE NEW POLE MOUNTED OR BUILDING MOUNTED ACCESSIBLE PARKING SIGNAGE 5. PAINT ACCESSIBLE AISLE AT EXISTING HARD SURFACE AREA AND PAINT ACCESSIBLE SYMBOL AT PARKING SPACE 1 WHEEL STOP NOTES: 1. SEE PLAN FOR LOCATION OF NEW WHEEL STOPS. WHEEL ST OP SHALL BE EQUAL OR BETTER THAN 6FT PLASTIC GRAY WHEEL STOP MODEL NO. H -2309GR 72X6X3 BY MANUFACTURER ULINE. INSTALL 3 QTY #4 REINFORCING BARS TO ANCHOR. EMBED AT LEAST 18". 2. SEE PLAN FOR UNMARKED GRAVEL PARKING SPACES TO LOCATE NEW WHEEL STOPS 1 1 1 1 1 1 ALL CONDITIONS ARE EXISTING. EXCEPT AS NOTED IN RED. THE GREEN AREAS ARE EXISTING LANDSCAPING. NO CHANGES ARE REQUIRED. GRADING IS NOT REQUIRED. THE WHITE IS EXSTING HARD SURFACE. NO CHANGES ARE REQUIRED. 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 No. Description Date 0 Issue for Construction 3/25/25 1 Permit Revisions 4/19/25 2 Permit Revisions 5/14/25 Page 67 of 107 Lancaster County Planning Department P. O. Box 1809 Lancaster, SC 29721 803.285.6005 planning@lancastercountysc.net 1081 Fort Mill Highway - B Fort Mill, SC 29707 Willtan LLC January 16, 2026 Volodymyr Nechyporuk Parcel(s) Stage Location Project Number Status Conditional Use Not Approved 0006-00-068.01 1081 B FORT MILL HWY INDIAN LAND Project Name Auto Repair 1081 B FORT MILL HWY INDIAN LAND 20252644 Dear: Volodymyr Nechyporuk We have completed our review of the plan identified above. The comments listed on the attached report must be addressed and revised plans submitted with a response letter. If the attached comments require changes to the plans, please submit the requisite number of sets, along with a pdf of the plan set on a CD, to the Lancaster County Planning Department. Once revised plans are received, they will be submitted to staff for review. *Please be aware that plans will not be routed for review without a response letter* Sincerely, Page 1 of 21/16/2026 Page 68 of 107 Plan Review Comments County Engineer - Terrance Barr - 803-286-3607 tbarr@lancastercountysc.gov Approved Review Comments: Ensure that erosion control measures are in place in accordance with South Carolina Department of Environmental Service Best Management Practices. Fire Marshal - Mike Magette - 8032838888 jmagette@lancastercountysc.gov Approved Review Comments: LC Water & Sewer District - Tim Kiser - 8032856919 tim.kiser@lcwasd.org No Review Needed Review Comments: SCDOT - David Gamble - (803) 385-4280 GambleDD@scdot.org No Review Needed Review Comments: Zoning - Julie Faile - 803-283-0567 jfaile@lancastercountysc.gov Conditional Review Comments: Zoning finds no issue with the Proposed Conditional USE, however an Upfit permit will be required for the lift installation. Contact Julie Faile at 803-283-0567 for any questions. Advisory Comments: Zoning finds no issue with the Proposed Conditional USE, however an Upfit permit will be required for the lift installation Planning - Kirsten Willis - 803-285-6005 kwillis@lancastercountysc.gov Not Approved Review Comments: Planning Commissions provides recommendation of approval or denial to County Council. All planner commentary and recommendation are strictly advisory. Status will remain "Not Approved" until case is heard by Planning Commission. Once Planning Commission provides recommendation, County Council will hear this Conditional Use application for one reading for approval or denial. Planning Commission Hearing: February 17, 2026 at 6:00pm in Council Chambers. Staff will be recommending approval. Page 2 of 21/16/2026 Page 69 of 107 9.2.16 CONDITIONAL USE A. APPLICATION PROCEDURES 1. Process Type: Legislative. 2. Applicants: Conditional Use permits may be submitted by any of the following: • Any owner of property within the land use jurisdiction of the County. 3. Pre-Application Procedure: Before filing a petition for a Conditional Use, an applicant shall meet with the Administrator to discuss the proposed Conditional Use request and to become more familiar with the applicable requirements and approval procedures of the County. Pre‗Submittal.Meeting.held.December.7❷th.℗ .76¿ 66am.with.Planning.Department¡ 4. Content of Application: A petition for a Conditional Use shall be filed on a form provided by the Administrator. Such a petition shall contain all the information required on the form and must be determined to be complete by the Administrator prior to advancing it through the review process. Application.submitted.December.7❷th? .868❶ ? .and.is.attached¡ 5. Determination of Completeness: Staff shall review an application for a Conditional Use to determine if it is complete. If an application is complete, the Administrator shall schedule the matter for consideration at a meeting of the Planning Commission. The Administrator shall prepare a staff report and recommendation on the matter. Pre‗ submittal.was.held.on.December.7❷th? .fee.was.paid.December.7❸th.and.scheduled.for.the. next.available.Planning.Commission.meeting? .per.application.deadline? .being.February.7❸th?. 868❷ ¡. B. REVIEW BY PLANNING COMMISSION 1. Public Notification (Prior to Planning Commission): Levels 1, 2, and 3 are required for Conditional Use applications. Statutory.notice.dates.are.listed.via.staff.report¡ 2. Neighborhood Meeting: Optional. No.neighborhood.meeting.was.held¡. 3. Consideration by Planning Commission: The Planning Commission shall conduct a public hearing and receive public input on the proposed use and shall provide a written recommendation to the County Council regarding whether to approve or deny the proposed use within 35 days of its first consideration on the matter. The recommendation shall address consistency with Chapter 5 and the surrounding neighborhood and other matters deemed appropriate by the Commission. A recommendation for denial of the petition shall not preclude consideration or approval of the proposed use by the County Council. Application.review.including.Planning.Commission" s.recommendation.will.be. scheduled.for.County.C ouncil.at.first.available.meeting? .likel y.March.❺th? .868❷ ¡. Page 70 of 107 5.8.6 VEHICLE SERVICES – MINOR MAINTENANCE/REPAIR [NB, GB, RB, LI, HI, MX, IMX] A. Outdoor Vehicle Storage : All outdoor storage of vehicles awaiting work or pick-up shall be screened by a Type C buffer in accordance with Section 7.1.5. No vehicles or awaiting work or pick-up shall be located closer than 5 feet to any adjoining property line, within a required landscape area, or in any right-of-way. No outside storage of junk vehicles or parts shall be permitted unless a permit for an outdoor storage yard is also obtained. Confirmed.with.Zoning.Dept¡? .buffer.requirements.are.met.via.grandfathered.status¡. Applicant.confirmed.via.pre‗submittal.meeting? .they.will.be.utilizing.the.parking. spaces.provided.(9).and.will.not.exceed.parking.beyond.those.spaces¡.Parking. space.location.meets.property.line.requirements¡. B. Vehicle Bays : Vehicle bays which are not set perpendicular to the street must be screened from direct view by a hedge or other landscaping. Bays facing the street must also incorporate awnings, windows, and/or other articulation/ornamentation sufficient to reduce the impact of the repair bays on the street as determined by the Technical Review Committee (TRC). Vehicle.bay.is.set.pe rpe ndicular.to.the.stree t.(F ort.Mill.Highway)¡ C. Noise: No noises resulting from the occasional repair or maintenance of a motor vehicle shall be audible at or beyond the property line between 8 PM and 7 AM the following morning. Intercom/sound systems shall not be audible at or beyond the property line. Applicant.confirmed.via.their.pre‗submittal.meeting? .their.operating.hours.will.not. fall.after.❹ pm.or.before.❸ am¡. D. Repair Work: All repair work shall be conducted entirely within an enclosed structure; car wash activities may be done outside when all requirements of stormwater management are met. Applicant.will.be.performing.work.inside.designated.garage.bay.area¡ E. Screening: All boundaries of a property containing such uses that directly adjoin a single-family residential district shall be buffered with a solid fence extending from the ground to a height of not less than 6 feet and a Type B buffer. Not.applicable·.applicant" s.site.does.not.neighbor.residential.districts¡ Page 71 of 107 F. Accessory Structure Location: Accessory structures such as self-service vacuum cleaners, air pumps, and other self-service structures must be setback 50 feet from any residential use and 25 feet from any right-of-way. Not.applicable·.applicant" s.site.does.not.have.an.accessory.structure¡. G. Fueling Islands: Each drive-up fueling facility permitted under this title shall have off- street driveway stacking space that shall not inhibit or impede access to or from any parking space or drive.. Not.applicable·.applicant.does.not.offer.fueling.services H. Lighting 1. Canopy lighting fixtures shall be hidden inside a canopy so as not to be visible from offsite. . Not.applicable·.site.does.not.include.a.canopy.structure¡ 2. Freestanding lighting fixtures shall not exceed 15 feet in height if the use adjoins an existing residential district or residential lot. All light fixtures shall be cutoff luminaries that block the light source from off-site view. Not.applicable·.applicant" s.site.does.not.neighbor.residential.districts.or.lots¡ I. Car Wash Allowed as Accessory Use: A one-bay car wash may be allowed as an accessory use. The car wash shall meet the setbacks for the principal use and not exceed 900 square feet in area. The car wash bay shall not be oriented toward the public right-of- way. Car washes are required to have operational recycled water systems where a minimum of 50 percent of water utilized is recycled. Not.applicable·.applicant.does.not.have.a.carwash.on.site¡. Page 72 of 107 Page 73 of 107 Page 74 of 107 Page 75 of 107 Page 76 of 107 Page 77 of 107 Lancaster County Unified Development Ordinance – Use Table DISTRICT STANDARDS 2.5 USES PERMITTED USE TYPES RURAL TRANSITIONAL SPECIAL NEIGHBORHOOD E. CIVIC AR RR RN RUB MH LDR MDR PB NB GB RB INS OSP LI HI M UR HDR RMX MX IMX REF Cemetery PR PR PR PR - PR PR - PR PR PR PR - - - - - PR - - PR 5.6.1 Conference/Convention Center - - - - - - - - - P P P - - - - - - - P P Cultural or Community Facility - - - P - - - - P P P P - - - - - - - P P Event Venue/Banquet Hall P P PR PR - PR PR PR PR PR PR PR - - - - - - - PR PR 5.6.2 Places of Assembly PR PR PR PR CU CU CU PR PR PR PR PR - PR - - - CU - CU CU 5.6.3 Private Recreation Facilities - - - PR - - - - PR PR PR PR - - - - - - - PR PR 5.6.4 Public Recreation Facilities PR PR PR PR PR PR PR PR PR PR PR PR PR - - - PR PR PR PR PR 5.6.5 Public Safety Station P P P P - - - P P P P P - P P - - - - P P Sports Arena/Stadium (4,000 or more seats) - - - - - - - - - - CU CU - CU - - - - - CU 5.6.6 F. EDUCATIONAL/INSTITUTIONAL AR RR RN RUB MH LDR MDR PB NB GB RB INS OSP LI HI M UR HDR RMX MX IMX REF Child/Adult Day Care Home (5 or fewer persons) PR PR PR PR PR PR PR PR PR PR PR PR - - - - PR PR - PR PR 5.7.1 Child/Adult Day Care Home (6 or more persons) - - - - - - - - PR PR PR PR - - - - - - - PR PR 5.7.2 College/University - - - - - - - - - - P - - - - - - - P P Community Support Facility - - - PR - - - - - PR PR PR - - - - - - - - - 5.7.3 Correctional Institution - - - - - - - - - - - CU - SE SE - - - - - - 5.7.4 Day Treatment Center - - - - - - - - - PR PR PR - PR - - - - - - - 5.7.5 Hospital - - - - - - - - - - P P - P - - - - - - - Operations, Maint., and Fleet Service Facility - - - SE - - - - - PR PR PR - PR PR - - - - - PR 5.7.6 Schools – Elementary and Secondary PR PR PR PR - PR CU CU CU CU CU PR - - - - CU CU CU CU CU 5.7.7 Schools – Vocational/Technical - - - P - - - - P P P P - P P - - - - P P Studio – Art, dance, martial arts, music P - - P - - - P P P P P - P - - - - - P P G. AUTOMOTIVE AR RR RN RUB MH LDR MDR PB NB GB RB INS OSP LI HI M UR HDR RMX MX IMX REF Drive-Thru/Drive-In Facility - - - PR - - - - CU PR PR - - PR PR - - - - PR PR 5.8.1 Electric Vehicle Charging Stations PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR PR 5.8.2 Heavy Equipment/Manufactured Home Rental/Sales/Repair - - - - - - - - - - SE - - PR PR - - - - - - 5.8.3 Parking Lot/Structure – Principal Use - - - - - - - - - PR PR PR - PR PR - - - - PR PR 5.8.4 Vehicle Rental/Leasing/Sales - - - PR - - - - - PR PR - - - - - - - - CU CU 5.8.5 Vehicle Services – Minor Maintenance/Repair - - - P - - - - CU CU PR - - PR PR - - - - CU CU 5.8.6 Vehicle Services – Major Repair/Body Work - - - PR - - - - - CU PR - - PR PR - - - - - - 5.8.7 P – Permitted by Right PR – Permitted with Review CU – Conditional Use Required SE – Special Exception Required UNIFIED DEVELOPMENT ORDINANCE | 11.28.2016 2-13 2 Page 78 of 107 Agenda Item Summary Ordinance # / Resolution # : N/A Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Information to Show on Agenda Below Title: Proposal: Property Details: Statutory Notices: Proposed Action Advances the Following Comprehensive Plan Guiding Principles: Points to Consider: Recommendation: Attachments: 1. NRN-February 2026 Staff Report 2. Combined Application & List 3. 6.11.3 Road Name Standards Amended 11-2024 4. Ch 6.11.2 - 6.11.4 New Road Names regulations Page 79 of 107 New Road Name NRN-2026-0011 Staff Report to Planning Commission Meeting Date: February 17, 2026 1 PROPOSAL: Approve road/street names in Lancaster County submitted via Civil Construction Plans and Preliminary Plats APPLICABLE LAWS: Chapter 6 of Lancaster County Unified Development Ordinance (UDO); SC Code of Laws 6-29-1200 APPLICANTS/DEVELOPMENTS: Asbury Development STATUTORY NOTICES: Posted signs not required. Mailed notices not required. Meeting notice (not required) published 01/231/2026 in The Lancaster News Published and Posted Agenda in lobby 02/10/2026 PROJECT SUMMARY & PROPOSAL: Proposal to approve street names in Lancaster County submitted via Civil Construction Plans and Preliminary Plats. BACKGROUND: The South Carolina Code of Laws, Section 6-29-1200 (A), states the following: (A) A local planning commission created under the provisions of this chapter [the South Carolina Local Government Comprehensive Planning Enabling Act of 1994] shall, by proper certificate, approve and authorize the name of a street or road laid out within the territory over which the commission has jurisdiction. It is unlawful for a person in laying out a new street or road to name the street or road on a plat, by a marking or in a deed or instrument without first getting the approval of the planning commission. In April 2023 Allison Hardin recommended bringing County practice into conformity with this state regulation. Staff brings new street names to the Commission for review and approval as needed for the orderly progression of workflow regarding Civil Plan and Preliminary Plat approvals, and an amendment has been drafted for inclusion in the UDO rewrite. UDO Chapter 6 defines the bases for approval as 1) that necessary public notice has been provided, 2) that correct application process has been observed, and 3) that the proposed name is not objectionable and does not conflict with existing street names. Page 80 of 107 New Road Name NRN-2026-0011 Staff Report to Planning Commission Meeting Date: February 17, 2026 2 STAFF RECOMMENDATION: Staff recommends approval of the street names listed in the attached application , having been reviewed by 911 Addressing for conformity to County standards for street names: ASBURY DEVELOPMENT: Redwood Dr Twinleaf Cir Narrowleaf Dr Alderwood Dr Field Daisy Ln Blue Violet Ct Silver Canoe Way ATTACHMENTS: 1. Application (Lancaster County) & List of Street/Road names submitted to 911 Addressing 2. Applicable code sections UDO Chapter 6 3. UDO Section 6.11.3 Road naming conventions STAFF CONTACTS: Jennifer Bryan, Planning Technician jbryan@lancastercountysc.gov (803-416-9433) Sandra Burton, 911 Addressing sburton@lanc911.com (803-416-9325) Page 81 of 107 Page 82 of 107 NEW ROAD NAMES: FEBRUARY 2026 GROUP SUBMITTAL The following road names have been submitted via Preliminary Plat and Civil Construction plans. All will be privately maintained. Road Name Development Redwood Dr Asbury Narrowleaf Dr Asbury Field Daisy Ln Asbury Silver Canoe Way Asbury Twinleaf Cir Asbury Alderwood Dr Asbury Blue Violet Ct Asbury Page 83 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-1 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 6.11.3 ROAD NAME STANDARDS A. The following shall specify the designation of road names. The road related definitions listed below shall apply to the development of street names, house or building numbers, and other addressing purposes. (Ord. No. 2019-1601, 9.23.19) 1. Any road in excess of 1,000 feet in length shall be designated as: a. Avenue (Ave): Avenues are often broad streets or roads; usually running perpendicular to streets. They serve as connectors between neighborhoods and area centers. As such, they are used both in residential and commercial areas. Avenues may also circulate around squares or neighborhood parks. b. Boulevard (Blvd): A broad, often landscaped, thoroughfare; usually a main artery. A median is usually in the middle. They provide multi-lane access to commercial and mixed-use developments and carry regional traffic throughout the County. c. Circle (Cir): A curving side street; usually a small residential street whose shape is circular. d. Drive (Dr): A long, winding road that has its route shaped by its environment, like a nearby lake or mountain. e. Highway (Hwy): A public way; a main direct road that joins cities or towns together. f. Road (Rd): A thoroughfare that runs in any direction. g. Street (St): A thoroughfare, especially in a city, town, or village, which is wider than an alley or lane and usually includes sidewalks. Usually runs perpendicular to avenues. h. Landing (LNDG): A place for unloading or taking on passengers and cargo [Added 11/12/2024 via Ordinance 2024-1935] 2. Any road less than 1,000 feet in length or any road that is cul-de-sac or any road that begins and ends on the same road shall be designated as: a. Alley (Aly): A narrow street; a thoroughfare through the middle of a block giving access to the rear of lots or buildings which are intended to provide indirect, limited access, but not accommodate through traffic. Utilities, either above ground or underground, and services such as garages, service doors, dumpsters, etc. may be located in alleyways to provide service connections to rear elevations. b. Court (Ct): A wide alley with only one opening onto a street; a road or street that ends in a circle or loop usually referred to as a cul-de-sac. c. Lane (Ln): Lanes are small, traveled ways intended to provide direct access to the front of a limited number of single-family structures. Lanes are limited in the number of lots served. Generally, they are very short; often less than 400 feet. Items including, but not limited to, traffic carrying capacity, topography, and connectivity, shall be a consideration when permitting a lane in lieu of a street. Page 84 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-2 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 d. Place (Pl): A small street or court; usually a small residential street or a narrow street in a commercial district. e. Terrace (Ter): A type of shorter, narrower road that follows the top of a slope. f. Trail (Trl): A winding thoroughfare. g. Way (Wy): A small side street off of a road. B. Any previously unnamed road or new road with center line offsets at intersections of less than 100 feet shall be given the same name, except in a subdivision. The roads will be allowed 2 separate road names under the discretion of the approval of the Lancaster County Addressing Coordinator. Excluding roads within an approved subdivision or PDD. C. Any continuous road shall have the same name over its entire length even though its direction may change. D. No road name hereafter established, regardless of suffixes or directionals, shall duplicate either phonetically or by spelling, another road name in the unincorporated area of Lancaster County or a neighboring county. This is to ensure emergency personnel are directed to the proper location in the correct jurisdiction. E. No road name hereafter established shall exceed 15 characters, including spaces and suffix abbreviations. If the subdivision provides their own signage, the character limit does not apply. F. No special characters, such as hyphens, apostrophes, periods, or decimals, shall be used. G. Areas of surrounding counties, which share Postal Service zip codes or multi- jurisdictional emergency services agreements with areas of Lancaster County, shall be considered when determining duplicates. H. The E-911 addressing department will not allow use of words which in its opinion are overused, either in the immediate area or county-wide, as such overuse is likely to cause confusion. I. Directional names (N, S, E, W or combination thereof) shall not be allowed. J. Proposed road names, which are intentionally misspelled, obscene, derogatory or other offensive words shall not be permitted. Page 85 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-3 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 Page 86 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-1 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 6.11.2 CONDITIONS OF ACCEPTANCE No new road shall be platted by the County until such road has been named as herein provided. A. A master list of the names, including suffixes of all roads and streets, within Lancaster County shall be maintained by the E-911 Coordinator and kept on file in the Planning Department. B. Road names on all plats must be first approved by the Planning Department/E-911 coordinator before the plat may be recorded in the Register of Deeds office. 6.11.3 ROAD NAME STANDARDS A. The following shall specify the designation of road names. The road related definitions listed below shall apply to the development of street names, house or building numbers, and other addressing purposes. (Ord. No. 2019-1601, 9.23.19) 1. Any road in excess of 1,000 feet in length shall be designated as: a. Avenue (Ave): Avenues are often broad streets or roads; usually running perpendicular to streets. They serve as connectors between neighborhoods and area centers. As such, they are used both in residential and commercial areas. Avenues may also circulate around squares or neighborhood parks. b. Boulevard (Blvd): A broad, often landscaped, thoroughfare; usually a main artery. A median is usually in the middle. They provide multi-lane access to commercial and mixed-use developments and carry regional traffic throughout the County. c. Circle (Cir): A curving side street; usually a small residential street whose shape is circular. d. Drive (Dr): A long, winding road that has its route shaped by its environment, like a nearby lake or mountain. e. Highway (Hwy): A public way; a main direct road that joins cities or towns together. f. Road (Rd): A thoroughfare that runs in any direction. g. Street (St): A thoroughfare, especially in a city, town, or village, which is wider than an alley or lane and usually includes sidewalks. Usually runs perpendicular to avenues. 2. Any road less than 1,000 feet in length or any road that is cul-de-sac or any road that begins and ends on the same road shall be designated as: a. Alley (Aly): A narrow street; a thoroughfare through the middle of a block giving access to the rear of lots or buildings which are intended to provide indirect, limited access, but not accommodate through traffic. Utilities, either above ground or underground, and services such as garages, service doors, dumpsters, etc. may be located in alleyways to provide service connections to rear elevations. b. Court (Ct): A wide alley with only one opening onto a street; a road or street that ends in a circle or loop usually referred to as a cul-de-sac. c. Lane (Ln): Lanes are small traveled ways intended to provide direct access to the front of a limited number of single-family structures. Lanes are limited in the number of lots served. Generally, they are very short; often less than 400 feet. Items including, but not limited to, traffic carrying Page 87 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-2 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 capacity, topography, and connectivity, shall be a consideration when permitting a lane in lieu of a street. d. Place (Pl): A small street or court; usually a small residential street or a narrow street in a commercial district. e. Terrace (Ter): A type of shorter, narrower road that follows the top of a slope. f. Trail (Trl): A winding thoroughfare. g. Way (Wy): A small side street off of a road. B. Any previously unnamed road or new road with center line offsets at intersections of less than 100 feet shall be given the same name, except in a subdivision. The roads will be allowed 2 separate road names under the discretion of the approval of the Lancaster County Addressing Coordinator. Excluding roads within an approved subdivision or PDD. C. Any continuous road shall have the same name over its entire length even though its direction may change. D. No road name hereafter established, regardless of suffixes or directionals, shall duplicate either phonetically or by spelling, another road name in the unincorporated area of Lancaster County or a neighboring county. This is to ensure emergency personnel are directed to the proper location in the correct jurisdiction. E. No road name hereafter established shall exceed 15 characters, including spaces and suffix abbreviations. If the subdivision provides their own signage, the character limit does not apply. F. No special characters, such as hyphens, apostrophes, periods, or decimals, shall be used. G. Areas of surrounding counties, which share Postal Service zip codes or multi- jurisdictional emergency services agreements with areas of Lancaster County, shall be considered when determining duplicates. H. The E-911 addressing department will not allow use of words which in its opinion are overused, either in the immediate area or county-wide, as such overuse is likely to cause confusion. I. Directional names (N, S, E, W or combination thereof) shall not be allowed. J. Proposed road names, which are intentionally misspelled, obscene, derogatory or other offensive words shall not be permitted. Page 88 of 107 6 SUBDIVISION AND INFRASTRUCTURE STANDARDS 6.11 STREET NAMES AND HOUSE NUMBERS 6-3 UNIFIED DEVELOPMENT ORDINANCE | Adopted 11.28.2016 6.11.4 PROCEDURE FOR NAMING A NEW ROAD A. Any person, firm, corporation, developer or right-of-way owner shall submit an application obtained from the Planning Department when requesting to name a new road. Such request shall include any descriptive/locational information required by the Planning Department; designate a spokesperson by name, address, and telephone number; provide first and second road name choices; and be accompanied by a petition, signed by 75 percent of the property owners with parcels having frontage on the affected road. B. If the request is consistent with standards included the section entitled "Road Name Standards," above, the Planning Department shall approve said request giving written notice of that action within 60 days of the date of such request. C. If the request is denied by the Planning Department, written notice including reasons for that action shall be provided within 60 days of the date of such request. D. Decisions of the Planning Department, whether affirmative or negative, shall be final subject to written appeal to Lancaster County Planning Commission filed with the clerk to the commission within 15 calendar days of the notice date of the Planning Department's decision. Such appeal shall set out the specific grounds upon which the Planning Department's decision is questioned. The fifteen-day appeal period shall commence on the date of the Planning Department's written notice of decision, which shall be sent to the person signing the affected road name request. E. A person laying out a street is guilty of a misdemeanor if he shows an unapproved street name on a plat, street marker or deed. If convicted, the court decides the punishment. F. Naming a previously unnamed road or driveway does not change the maintenance responsibility; if it was privately maintained prior to its naming, it will remain privately maintained. G. Any road or driveway, whether publicly or privately maintained that serves as the sole access for three (3) or more permanent residential or business structures must be named. (Ord. No. 2017-1485, 1.8.18) Page 89 of 107 Agenda Item Summary Ordinance # / Resolution # : Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Council Action Requested: Strategic Plan Focus Alignment: Points to Consider: Funding and Liability Factors: Recommendation: Attachments: None Page 90 of 107 Agenda Item Summary Ordinance # / Resolution # : N/A Contact Person / Sponsor: Department: Date Requested to Be on Agenda: 2/17/2026 Information to Show on Agenda Below Title: Proposal: Property Details: Property Location: Current Zoning District: Proposed Zoning District: Applicant: Council District: Statutory Notices: Proposed Action Advances the Following Comprehensive Plan Guiding Principles: Points to Consider: Recommendation: Attachments: 1. PC Proposals -2 (Cureton) 2. PC Proposal forms (2) Page 91 of 107 Page 92 of 107 Page 93 of 107 Page 94 of 107 Page 95 of 107 Page 96 of 107 Page 97 of 107 Page 98 of 107 Page 99 of 107 Page 100 of 107 Page 101 of 107 Page 102 of 107 Page 103 of 107 Page 104 of 107 Page 105 of 107 Page 106 of 107 Page 107 of 107

Source: Lancaster County website. First collected Nov 3, 2026.