RecordWell Data

Design Review Board Meeting — Agenda Packet

Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Jul 8, 2025 · Agenda packets

Open the original document More from Town of Hilton Head Island

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Town of Hilton Head Island Design Review Board Meeting Tuesday, July 8, 2025, 2:30 PM 1 Town Center Court, Hilton Head Island, SC Benjamin M. Racusin Council Chambers The Design Review Board meeting will be held in person at Town Hall in the Benjamin M. Racusin Council Chambers. 1. Call to Order 2. Adoption of the Agenda 3. Approval of the Minutes a. Regular Meeting Minutes of June 24, 2025 4. Unfinished Business 5. New Business a. DRB-000605-2025 - Hilton Head Island Old Schoolhouse Park Toilet Facility - Conceptual 6. Public Comment - Non Agenda Items 7. Board Business 8. Staff Reports 9. Adjournment FOIA Compliance: Public notification of this meeting has been published, posted, and distributed in compliance with the South Carolina Freedom of Information Act and the requirements of the Town of Hilton Head Island. In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Hilton Head Island ADA Coordinator as soon as possible but no later than 48 hours before the scheduled event. Page 1 of 46 Municipal Association of South Carolina (MASC) Civility Pledge: “I pledge to build a stronger and more prosperous community by advocating for civil engagement, respecting others and their viewpoints, and finding solutions for the betterment of my city or town.” Page 2 of 46 Town of Hilton Head Island Design Review Board Meeting Minutes 6/24/2025 Page | 1 Town of Hilton Head Island DESIGN REVIEW BOARD MEETING Tuesday, June 24, 2025, 2:30 PM Minutes 1. Call to Order The meeting was called to order at 2:30pm. 2. Adoption of the Agenda Mr. Parker made a motion to approve the agenda. Ms. Fitzpatirck seconded the motion, which passed unanimously. 3. Approval of the Minutes a. Regular Meeting Minutes of June 10, 2025 Mr. Parker made a motion to approve the meeting minutes of June 10th. Ms. Pastor seconded the motion, which passed unanimously. 4. Unfinished Business a. DRB-000348-2025 - 862 William Hilton Parkway - Beach Properties - Sign System Melissa Pual-Leto, Principle Planner, presented the Beach Properties Sign System. The applicant answered questions from the Board. Ms. Pastor made a motion to approve with the following conditions: study the scale of the gooseneck lighting and submit to Staff for review; move the street address numbers on the monument sign up higher or ensure that they're not obscured by landscaping; submit a landscape plan to Staff for approval. Mr. Parker seconded, which passed unanimously. 5. New Business a. DRB-000574-2025 - 70 Wilborn Road - Hilton Head Island High School - Alteration Ms. Paul-Leto presented the Hilton Head Island High School conceptual review for Phase 2 to the Board. The applicant answered questions from the Board. Mr Parker made a motion to approved with the following conditions: adhere to all Staff comments; incorporate design cues from phase 1 so that they speak to each other a bit more; introduce plant beds to the large paved area in front of the multipurpose room; all windows and overhead doors should be dark bronze; all lighting and materials to match phase 1; lighting to be coordinated among all the plans, especially the landscaping and civil plans; extend the parking access wherever we have a pedestrian aisle down the middle of the parking lots; look at extending those pathways for overflow parking when Page 3 of 46 Town of Hilton Head Island Design Review Board Meeting Minutes 6/24/2025 Page | 2 people come to large sports events; think through the circulation access from all parking lots for large events or games; provide service yard detailing and locations; the outdoor classroom screen detailing to be submitted in the next package for review and the top line be more organic to go along with the fence detailing; introduce two shades of blue to make it more similar to phase 1. Mr. Theodore seconded the motion, which passed unanimously. b. DRB-000580-2025 - 93 Matthews Drive - Food Lion - Conceptual Vice Chair Lippert recused herself, passed the gavel to Mr. Parker, and left the room. Ms. Paul-Leto presented Food Lion for conceptual review. The applicant answered numerous questions from the Board. After further review, the Board suggested tabling the application, and the applicant withdrew the application until a later date. 6. Public Comment - Non Agenda Items 7. Staff Reports 8. Board Business Vice Chair Lippert returned to the dias. The Board discussed observed potential design code violations and design concerns around the island. 9. Adjournment The meeting adjourned at 5:07. The recording of this Meeting can be found on the Town’s website at www.hiltonheadislandsc.gov Page 4 of 46 Page 5 of 46 Last Revised 01/21/15 1 Applicant/Agent Name: ______________________________ Company: _____________________________________ Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________ Telephone: ___________________ Fax: _________________ E-mail: _______________________________________ Project Name: _________________________________ Project Address: _____________________________________ Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ Zoning District: _______________________________ Overlay District(s): ___________________________________ Town of Hilton Head Island Community Development Department One Town Center Court Hilton Head Island, SC 29928 Phone: 843-341-4757 Fax: 843-842-8908 www.hiltonheadislandsc.gov CORRIDOR REVIEW, MAJOR DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS Digital Submissions may be accepted via e-mail by calling 843-341-4757. Project Category: _____ Concept Approval – Proposed Development _____ Alteration/Addition _____ Final Approval – Proposed Development _____ Sign FOR OFFICIAL USE ONLY Date Received: _____________ Accepted by: ______________ DRB #:___________________ Meeting Date: _____________ Submittal Requirements for All projects: _____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16- 2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the applicant. _____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175, Alterations/Additions $100, Signs $25; cash or check made payable to the Town of Hilton Head Island. Additional Submittal Requirements: Concept Approval – Proposed Development _____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and beaches. _____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks, views, orientation and other site features that may influence design. _____ A draft written narrative describing the design intent of the project, its goals and objectives and how it reflects the site analysis results. _____ Context photographs of neighboring uses and architectural styles. _____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping. _____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed development, materials, colors, shadow lines and landscaping. Dale N. Strecker Hord Coplan Macht P.O. Box 5910 Hilton Head Island SC 29938 843-785-2199 dstrecker@hcm2.com Old Schoolhouse Park Toilet Facility 150 & 152 William Hilton Parkway R 511 007 000 0247 0000 (#150) & R 511 007 000 0070 0000 (#152) COR PR N/A ** Filing fee to be paid by the Town of Hilton Head Island ** Page 6 of 46 Page 7 of 46 ARCHITECTURE LANDSCAPE ARCHITECTURE INTERIOR DESIGN PLANNING 10 Palmetto Business Park Rd Suite 201 Hilton Head Island, SC 29928 P 843.785.2199 www.hcm2.com June 18, 2025 Community Development Staff Town of Hilton Head Island One Town Center Court Hilton Head Island, SC 29928 Subject: Old Schoolhouse Park Toilet Facility – Major Desig n Review Board Submittal Project Narrative Need for the Project: The Town’s Old Schoolhouse Park located at 152 William Hilton Parkway currently provides open field space, a basketball court, six pickleball courts, and a gravel parking area serving the park. The park currently has no toilet or handwashing facilities and is served by a single portable toilet. There is currently no covered area to protect park users from the elements. This project is for a new building to be located adjacent to the existing pickleball court that would include a toilet room with running water, a covered porch for protection of users from the elements, a drinking fountain, and a storage room for use by the Town. Scope of Work: All existing elements on the site will remain largely as-is. The open field space, basketball court and pickleball courts will remain. The gravel parking area will be modified to incorporate a paved handicapped parking space and a concrete sidewalk will be added connecting the handicapped parking space to the existing sidewalk encircling the pickleball courts. The new toilet building will directly abut the existing concrete sidewalk at the pickleball courts in what is currently grassy area. No existing trees will be removed or impacted as part of the work. New landscaping would be provided adjacent to the new building. Site Analysis: The site is in the Parks & Recreation (PR) Zoning District. The area where the toilet building is proposed to be located is currently level, open, grassy space located on high ground and away from any wetlands. There are no trees within or near the area of proposed work. The building is proposed to be sited in an area well away from required setback and buffer areas. The building will be placed adjacent to the pickleball courts, approximately 250’ from the edge of the sidewalk at William Hilton Parkway. Due to the building’s proposed location, it will be minimally visible from the road and no buffers or setbacks will be impacted or modified. Page 8 of 46 Page 2 of 2 Building Design: The new building will be 17’-4” wide by 24’-2” long and will encompass approximately 174 square feet of enclosed area, with the balance of building area being covered porch. The building has been designed to be nearly identical to a similar facility at the Town’s Cordillo Tennis Courts facility on Cordillo Parkway. That structure, however, is located below flood elevation and thus has removable flood barriers at the doorway openings. This building will be located above flood elevation and has been simplified to omit the removable flood barriers. All building materials, finishes, and colors will match those at the Cordillo Tennis Courts facility. The selection of similar materials, colors, and other elements will allow the Town to maintain consistency of their park facilities across the Island. Kind regards, Hord Coplan Macht Dale N. Strecker, AIA Project Manager cc: Neal Eike, Town of Hilton Head Island Page 9 of 46 Page 10 of 46 Untitled Map Write a description for your map. Legend 152 William Hilton Pkwy 1000 ft N➤➤ N Property Line Proposed Structure Town sidewalk / pathway along edge of property, directly abutting William Hilton Parkway Spanish Wells Road Wild Horse Road Old Schoolhouse Park Site - Town Vicinity Map Existing Pickleball Courts Existing Basketball Court Page 11 of 46 Exhibit 4A Consolidation Plat joining 150 & 152 William Hilton Parkway into one property. Page 12 of 46 Exhibit 4B Survey of property without proposed improvements. Page 13 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility 150 & 152 William Hilton Parkway Design Review Board (DRB) Context Photographs View of site from William Hilton Parkway. Building will be approximately 100’ beyond white car. View of adjacent property to the west. Page 14 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 2 of 7 View of adjacent property to the west. View of property on opposite side of William Hilton Parkway. Page 15 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 3 of 7 View of property on opposite side of William Hilton Parkway. View of property on opposite side of William Hilton Parkway. Page 16 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 4 of 7 View of home at east side of Old Schoolhouse Park. View of Old Schoolhouse Park and proposed site from entry into parking lot. Building Site Page 17 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 5 of 7 View of Old Schoolhouse Park and proposed site from the east. Pickleball courts on the left. View of proposed building site between pickleball courts and existing wooded area. Building Site Building Site Page 18 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 6 of 7 View of proposed building site between pickleball courts and existing wooded area. View of proposed building site between pickleball courts and existing wooded area. Building Site Building Site Page 19 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Context Photographs Page 7 of 7 View of proposed building site between pickleball courts and existing wooded area. Building Site Page 20 of 46 ABBREVIATIONS A B C D E F H I J K L M N O P R S T V W Q G T A.C. A.D. A.H.U. A.T.C. A.T. ARCH. APPROX. A.O. AMP., A. ALUM. ALT. A.F.F. B.T.U. BRK BRG. BOT. BM. BLK. BLDG. BD. BAL. CAB. CAP. C/B C.D. CEM. CER. C.F.C.I. C.F.M. CIRC. C.J. CK'D CIR L, CL. CEIL. CL. C.O. COL. CONC. COND. CONN. CONST. CONT. CONTR. JT. C.T. C. TO C. C DET. DIA. DIFF. DIM. DISC. D.J. DN. DR. D.S. DWG.(S) EA. E.C. E.F. EL. ELEC. EQUIP. E.W.C. EXH. EXT. EXIST. F.A. F.C. F.D. F.E.C. FIN. FL. FT. FTG. FFE F.E. GA. GAL. GALV. GL. GND. GOV'T GPH GPM GR. GWB GYP. H. H.B. H.C. HT. HM H.P. HR. HTG. HTR. H.&V. HW. HYD. I.D. I.E. IN. INCAND. INSUL. INT. J.B. JCT. JT. KVA KW LB.,# LG. L.P. LTG. M. MAINT. MAX. M.D.P. MECH. MTL. MIN. MISC. M.O. MTD. MTG. M.V. M.G.T. N.A. N.I.C. NO. O.A. O.C. O.D. OH. OPNG. OPP. O.S.B. PART. PER. L, PL. PLBG. PLYW'D PNL. PRESS. PSF PSI P.T. PTD. QTR. QUAN. R. R.A. RAD. RD. REC'D. RECIRC. RECP. REINF. REQ. RET. R.G. RM. R.P.M. T. TEL. TEMP. THK. THD. TOIL. TYP. VCT VENT. VERT. VTR W/ WD. WF W.G. WP. S.A. SCH. SECT. SERV. SHT. S.J. SQ. FT. ST. STOR. STRUCT. SUSP. SW. S. SIM. P O.H. MAT. PR. SPEC. SLR. STN. O.S.D. O.F.E. O.F.C.I. O.F.O.I. OWNER FURNISHED/ E.I.F.S. STL. MFR. E.J. M.B. T.B. S.S. STAINLESS STEEL BR CG C.M.U. AIR CONDITIONED AREA DRAIN AIR HANDLING UN ABOVE FINISHED FLOOR ALTERNATE ALUMINUM AMPERES ACCESS OPENING APPROXIMATELY ARCHITECTURAL ASPHALT TILE ACOUSTIC TILE CEILING BALANCE BOARD BUILDING BLANK BEAM BOTTOM BUMPER RAIL BEARING BRICK BRITISH THERMAL UNIT CABINET CAPACITY CIRCUIT BREAKER CEILING DIFFUSER CEMENT CERAMIC CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CUBIC FEET/MINUTE CORNER GUARD CIRCULATING CONTROL JOINT CHECKERED CIRCUIT CENTER LINE CEILING CLOSET CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONDENSATE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTION JOINT CERAMIC TILE CENTER TO CENTER DETAIL DIAMETER DIFFUSER DIMENSION DISCONNECT DUMMY JOINT DOWN DRAIN DOWN SPOUT DRAWING(S) EACH EMPTY CONDUIT EXHAUST FAN EXTERIOR INSULATION AND FINISHING SYSTEM ELEVATION ELECTRIC EQUIPMENT ELECTRIC WATER COOLER EXHAUST EXPANSION JOINT EXTERIOR EXISTING FIRE ALARM FLEXIBLE CONNECTION FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FOOT, FEET FOOTING ELEVATION FINISHED FLOOR GAGE GALLON GALVANIZED GLASS GROUND GOVERNMENT GALLONS/HOUR GRILLE GALLONS/MINUTE GYPSUM WALL BOARD GYPSUM HIGH HOSE BIBB HOLLOW CORE HEIGHT HOLLOW METAL HORSE POWER HOUR HEATING HEATER HARDWARE HYDRANT INSIDE DIAMETER INVERT ELEVATION INCHES INCANDESCENT INSULATION INTERIOR W.W.F. WELDED WIRE FABRIC WEATHERPROOF WATER GAGE WIDE FLANGE WOOD WITH VENT THRU ROOF VERTICAL VENTILATION NYL COMPOSITE TILE TYPICAL TOILET THRESHOLD THICKNESS TEMPERATURE TELEPHONE TACK BOARD TOILET SWITCH SUSPENDED STRUCTURAL STONE STORAGE STEEL STAINED SQUARE FEET SEALER SPECIFICATIONS SLIP JOINT SIMILAR SHEET SERVICE SECTION SCHEDULE SUPPLY AIR SUPPLY REVOLUTIONS/MINUTE ROOM RETURN GRILLE RETURN REQUIRED REINFORCING RECEPTACLE RECIRCULATING RECESSED ROOF DRAIN RADIUS RETURN AIR RISER QUANTITY QUARTER PAINTED PRESSURE TREATED POUNDS/SQUARE INCH POUNDS/SQUARE FOOT PRESSURE PAIR PANEL PLYWOOD PLUMBING PLATE PERIMETER PARTITION OPEN SIGHT DRAIN ORIENTED STRANDBOARD OPPOSITE OPENING OVERHEAD OPPOSITE HAND OWNER INSTALLED OWNER FURNISHED/ CONTRACTOR INSTALLED OUTSIDE DIAMETER ON CENTER OUTDOOR AIR NUMBER NOT IN CONTRACT NOT APPLICABLE MATT GLAZE TILE MECHANICAL VENTILATION MOUNTING MOUNTED MASONRY OPENING MISCELLANEOUS MINIMUM METAL MANUFACTURER MECHANICAL MAIN DISTRIBUTION PANEL MARKER BOARD MAXIMUM MATERIAL MAINTENANCE MOTOR LIGHTING LIGHTING PANEL LONG POUND KILOWATT KILOVOLT AMPERE JOINT JUNCTION JUNCTION BOX VENTILATING HEATING AND EQUIPMENT OWNER FURNISHED U.N.O UNLESS NOTED OTHERWISE MATERIALS LEGEND BRICK (SEE PLANS AND DETAILS FOR ALTERNATE CONFIGURATIONS) CONCRETE GROUT, MORTAR, SAND EARTH COMPACTED SOIL CMU (SEE PLANS AND DETAILS FOR ALTERNATE CONFIGURATIONS ROUGH LUMBER (DISCONTINUOUS ROUGH LUMBER (CONTINUOUS) BLOCKING) FINISH WOOD ALUMINUM FERROUS METALS - STEEL POROUS FILL GLAZING GYPSUM WALLBOARD (LARGE SCALE) PLYWOOD RIGID INSULATION ACOUSTIC TILE CARPET BATT INSULATION PROJECT TEAM NAME OF PROJECT: TOWN OF HILTON HEAD ISLAND - OLD SCHOOLHOUSE PARK TOILET FACILITY ADDRESS: 152 WILLIAM HILTON PARKWAY HILTON HEAD ISLAND, SOUTH CAROLINA, 29926 DISCIPLINE DESIGNER CONTACT PHONE NUMBER ARCHITECT HORD COPLAN MACHT BARRY H. TAYLOR, AIA, LEED 843 -785 -2199 STRUCTURAL ENGINEER SHEARLOCK ENGINEERING JAKE EAVENSON, PE 843 -473 -8767 PLUMBING ENGINEER MECHANICAL ENGINEER ELECTRICAL ENGINEER CDDC RYAN M. YOCCO, PE 843 -384 -4731 OWNER CONTACT: NEAL EIKE, SENIOR PROJECT MANAGER, TOWN OF HILTON HEAD ISLAND ISLANDS ENGINEERING CARL QUANTE, PE 912 -356 -9036 ISLANDS ENGINEERING CARL QUANTE, PE 912 -356 -9036 CIVIL ENGINEER STURRE ENGINEERING NATHAN STURRE, PE 843 -929 -9432 GENERAL NOTES 1. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED ON DRAWINGS FOR LAYOUT OF WORK. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LISTED BUILDING CODES AND WITH THE MOST STRINGENT BEING ENFORCED WHERE A CONFLICT ARISES. 3. THE HOURS AND DAYS OF OPERATION SHALL CONFORM TO OWNER'S REQUIREMENTS. VERIFY WITH OWNER. 4. THE SCHEDULING OF WORK WHICH PRODUCES EXCESSIVE NOISE OR VIBRATION SHALL BE SHCEDULED WITH THE OWNER'S REPRESENTATIVE. THE OWNER'S REPRESENTATIVE SHALL DEFINE THE TERM "EXCESSIVE". 5. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT IN WRITING IMMEDIATELY UPON DISCOVERY OF CONDITIONS WHICH ARE IN CONFLICT WITH CONTRACT DOCUMENTS. ABBREVIATIONS SYMBOLS ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ELEVATION INDICATOR SECTION MARK DOOR INDICATOR EXTERIOR ELEVATION MARK ELEVATION NUMBER SHEET NUMBER SHEET NUMBER SECTION NUMBER DIRECTION OF VIEW NAME ELEVATION SIM 1 A-101 101 REF REF REF REF A101 1 1 1 1 MATERIALS LEGEND Table 5.6-2. BASIC CODE REVIEW INFORMATION B. Municipality and/or County Where Project is Located: C. Jurisdiction for: (Provide the name of the applicable authority) 1. Site Work: 3. Water: 4. Sewer: 1.2. Is Project in a Flood Plain? Yes No If building is a mixed occupancy per IBC 302.3, indicate the additional occupancy groups present: 3 Type of Construction (per IBC Chapter 6): (All site information is required if project affects the site or if site information is necessary for design purposes. All floodplain information is required even if project does not affect site and is not in flood plain. 1.1 Total Area of Project Site (in acres): 5. Zoning: Land Use Zone: A. Flood Map Information: Community No.: Panel No.: B. Flood Zone: Base Flood Elevation (BFE): 1.3. Is Project in Wetlands Area? Yes No (per IBC Chapter 3) 1 Site Development 2 Occupancy A. Construction Classification: B. Is the building construction protected or unprotected C. Is the building construction of combustible or noncombustible materials A. Occupancy Classification: Group: B. Additional Occupancy Classification(s) Group: 2. Fire Department: Project in Fire District? Yes No Table 5.6-6: Fire Resistance Rating of Building Elements Building Element Structural Frame Including Columns, Girders and Trusses (per IBC Table 601) Bearing Walls, Exterior (per IBC Table 601) C. Building Lowest Floor Elev.: A. Total Area of Project Site that will be Disturbed/Developed : Project Designed in Accordance With: 1. International Building Code, 2021 Edition with SC Modifications 2. International Energy Conservation Code, 2009 Edition 3. International Fire Code, 2021 Edition with SC Modifications 4. International Plumbing Code, 2021 Edition with SC Modifications 5. National Electrical Code, NFPA 70, 2020 Edition with SC Modifications 6. ICC/ANSI-A117.1-2017, Accessible and Usable Buildings and Facilities 7. NFPA 101 Life Safety Code, 2012 Edition 0 0 N/A 0 0 0 0 0 N/A Hilton Head Island, SC Hilton Head Island, SC Hilton Head Island, SC N/A 0 0 00 N/A N/A N/A N/A N/A Utility & Accessory U N/A Unprotected Combustible 0 0 0 N/A N/A Type VB Hilton Head PSD Less than 1/4 Acre PR - Parks & Recreation X Hilton Head PSD Rating As Designed (in hours) Rating As Required (in hours) Testing Agency & Design Number (UL, FM, etc.) Bearing Walls, Interior (per IBC Table 601) Non-bearing Walls & Partitions, Exterior (per IBC Table 601) Non-bearing Walls & Partitions, Interior (per IBC Table 601) Floor Construction, Including Supporting Beams & Joists (per IBC Table 601) Roof Construction, Including Supporting Beams & Joists (per IBC Table 601) Fire Walls (per IBC Table 705.4) Fire Barriers (per IBC Table 706.3.9) Shaft Enclosures (per IBC Section 707 Fire Partitions (per IBC Section 708 Parks & Recreation X and X-Shaded 11.0' TBD' MSL X BASIC CODE INFORMATION VICINITY MAP LIST OF DRAWINGS GI -100 GENERAL INFORMATION S300 FOUNDATION DETAILS PLUMBING P1.0 PLUMBING WATER/SEWER PLAN, SCHEDULES FLOOD DESIGN STRUCTURAL CALCULATIONS STRUCTURAL MECHANICAL M1.0 MECHANICAL HVAC PLAN AND SCHEDULES ELECTRICAL E-001 ELECTRICAL NOTES AND SCHEDULES E-100 ELECTRICAL PLANS AND DETAILS S100 STRUCTURAL NOTES GI -110 PROJECT NOTES AND SPECIFICATIONS S200 FOUNDATION PLAN AE -101 PLANS AE -301 SECTIONS / DETAILS ARCHITECTURAL C-1 TITLE SHEET AE -601 DOOR SCHEDULE & DETAILS AI -201 INTERIOR ELEVATION / FINISH SCHEDULE C-2 GENERAL NOTES & LEGEND CIVIL AE -201 BUILDING ELEVATIONS & SECTIONS E-200 ELECTRICAL SITE PLAN C-3 EXISTING CONDITIONS C-4 DEMOLITION & SWPP PLAN C-5 SWPPP DETAILS C-6 SWPPP DETAILS AS -101 ARCHITECTURAL SITE PLAN C-7 SITE IMPROVEMENTS PLAN C-8 GRADING & DRAINAGE PLAN C-9 UTILITY PLAN C-10 CIVIL DETAILS C-11 UTILITY DETAILS C-12 UTILITY DETAILS S400 STRUCTURAL DETAILS THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:34 PM GI-001 GENERAL INFORMATION 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 dns bht Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 Town of Hilton Head Island OLD SCHOOLHOUSE PARK TOILET FACILITY ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT 11/15/2024 Town Pre-Application Submittal 3/31/2025 Town DPR Application P1.0 PLU ELECTRICAL E-100 ELECTRICAL PLANS AND DETAILS Page 21 of 46 FD OCRM CRITICAL LINE 50.00' ACCESS EASEME NT (PER PB:45 PG:67) ±12LF 18" RCP @ 0.33% ZONE X (0.2% CHANCE) FLOOD ZONE X FLOOD ZONE X ZONE X (0.2% CHANCE) ZONE X (0.2% CHANCE) ZONE AE ELEV. 9' CONCRETE SIDEWALK CONCRETE SIDEWALK ±168LF 30" RCP @ 0.23% SDMH RIM:9.92' SUMP:3.52' SED:3.89' WSE:4.18' (3-3-23) IE(SE):4.20' IE(S):4.29' IE(NW):4.21' GI RIM:8.10' SUMP:4.25' IE(N):4.25' ±172LF 30" RCP @ 0.19% GI RIM:8.96' IE(N):CNA ±9LF 18" RCP SDMH RIM:11.14' SUMP:4.34' SED:4.62' WSE:4.85' (3-3-23) IE(SE):4.72' IE(NW):4.56' IE(N):4.70' ARVMH (FMMH) RIM:9.97' PD FORCE MAIN PD 4" PVC 18 MAG 18 LA 31 LO 14 SYC 11 9 HO 10 HO 16 HO 17 P 13 PAL 18 CED 15 10 9 HO 14 8 SB 11 7 HO 12 8 6 HO 9 6 MAG 16 SYC 17 LO 12 11 WO 21 SYC 8 HO 8 5 HO 19 LO 13 9 7 HO 11 PAL 8 6 HO 31 LO 28 SYC 7 6 HO 26 LO 14 PAL 13 SYC 11 PAL 16 LO 13 PAL 15 PAL 40 SYC 9 PAL 14 LA 12 LO 17 CH 15 LA 13 LO 12 LO 34 LO 20 LO 17 LO 13 9 LA 10 LA 14 13 CH 13 LO 69 LO 8 LA 10 LA 29 23 LO 15 WO 10 WO 8 MAG 10 9 BP 72 LO 25 PEC 8 WO 20 SB 16 G 14 G 11 WO 9 P 29 LO 25 LO 16 LO 14 PAL 11 PAL 14 PAL 11 PAL 12 11 G 15 PAL 13 PAL 14 DEAD 10 G 42 LO 15 PAL 15 PAL 34 LO 16 LO 15 PAL 13 PAL 13 PAL 11 PAL 9 9 8 LO 16 PAL 28 LO 9 LA 29 LA 16 LA 15 PEC 12 LA 11 CH 10 CH 9 LA 9 LO 13 LA 12 WO 12 SYC 10 LA 13 12 11 LO 17 LA 11 WO 11 WO 24 LO 15 LO 24 LO 8 P 29 P 20 LO 15 G 12 PAL 23 DEAD 20 15 9 LO 19 DEAD 18 14 LO 12 LO 18 P 8 P 7 LO 17 LO 13 LA 9 LO 18 LO 18 LO 14 LO 14 LO 14 LO 10 DEAD 31 LA 16 PAL 13 LA 10 SB 13 LO 11 LA 13 PAL 7 LO 14 PAL 10 LO 7 9 LO 13 PAL 15 PAL 14 PAL 20 LO 12 PAL 29 LO 50 LO 21 LO 13 PAL 13 PAL 31 LA 20 9 LO 20 LO 14 WO 10 LO 10 LA 10 LO 17 LO 16 G 11 PAL 25 14 LO 20 20 16 15 LO 16 PAL 12 PAL 14 DEAD 14 LA 12 LO 19 LA 10 G 34 LO 12 PAL 15 LO 14 LO 22 LA 8 G 14 PAL 14 PAL 16 15 CH 8 6 MAP 8 LO 16 LO 15 LO 19 DEAD 12 G 10 10 11 10 10 11 12 12 12 11 10 11 8 9 7 6 5 11 10 5 8 7 55 6 9.52 9.08 8.97 8.97 8.97 9.43 10.1 9.6 10.27 9.94 10.28 11.1 10.5 9.73 9.8 9.10 9.54 9.4 9.5 9.35 9.31 9.88 9.74 9.5 10.4 10.1 9.9 10.27 10.09 10.3 10.16 9.9 9.9 9.59 10.01 10.53 10.6 10.77 9.7 9.96 9.80 10.80 10.65 10.68 10.50 10.58 10.76 11.0 10.67 10.72 10.92 10.99 10.97 10.92 11.6 11.0 11.5 10.96 11.6 11.5 11.1 11.0 10.7 10.9 11.1 11.0 10.53 10.7 11.2 11.3 11.34 11.29 11.4 11.1 10.74 10.59 11.9 10.6 9.19 10.38 9.07 10.50 9.08 10.36 11.0 9.9 9.8 10.37 10.02 9.86 9.6 9.8 10.24 10.9 11.1 10.63 10.13 10.51 11.29 11.83 11.30 11.45 10.96 11.32 11.18 11.19 11.23 11.48 11.07 11.2 11.09 11.01 11.31 11.7 11.3 11.29 11.29 11.5 11.4 11.6 12.0 11.8 11.7 11.37 10.95 9.93 11.0 11.3 11.6 11.4 11.6 11.7 11.5 11.1 11.0 11.9 11.8 12.0 11.8 11.6 11.7 12.2 11.51 11.5 11.51 11.76 11.49 11.5 12.0 11.9 12.2 11.73 11.7 11.9 11.8 13.0 11.9 11.9 11.9 12.0 12.0 11.7 11.5 11.6 12.0 11.8 11.3 11.1 11.6 11.9 11.3 11.5 11.3 11.3 11.4 11.5 10.9 11.4 10.8 11.1 11.6 11.43 10.76 10.7 10.9 11.5 11.4 11.7 11.5 11.3 11.4 11.7 11.3 11.5 10.9 11.2 11.3 11.8 11.4 11.2 9.9 10.3 9.0 9.1 11.0 11.2 10.5 9.4 11.2 11.0 11.3 10.2 5.9 9.2 4.2 10.4 10.5 4.9 5.5 8.9 8.0 5.2 5.7 6.6 4.7 6.3 7.4 4.2 11.4 11.5 10.83 11.01 10.84 9.9 10.6 10.8 9.5 10.0 10.51 9.5 9.5 10.43 4.3 3.9 5.0 8.5 7.1 6.8 6.3 7.0 5.4 4.9 9.3 9.0 8.8 8.6 9.2 9.9 9.4 9.5 9.1 9.4 8.0 6.7 7.0 8.2 4.5 4.3 3.3 6.6 5.9 6.3 7.7 7.4 6.1 4.3 4.2 8.8 8.3 7.3 6.3 6.0 2.9 4.1 3.8 8.1 3.9 3.9 3.9 BOC WILLIAM HILTON PARKWAY U.S. HIGHWAY 278 R/W VARIES N/F TOWN OF HILTON HEAD ISLAND TMS R511 007 000 0070 0000 PB:45PG:67 DB:2410PG:2126 124,877 S.F. 2.867 AC. N/F KENNETH & MARGARETE JAMES TMS R511 007 000 0072 0000 PB:33PG:18 DB:3204PG:2165 N/F TUAN Q. NGUYEN TMS R511 007 000 072D 0000 PB:36PG:180 DB:3140PG:178 N/F BEAUFORT COUNTY TMS R511 007 000 0247 0000 PB:45PG:67 162,556 S.F. 3.732 AC. PICKLEBALL COURT N/F TOWN OF HILTON HEAD ISLAND TMS R511 007 000 072A 0000 DB:3919PG:2593 BASKETBALL COURT N/F HILTON HEAD CO INC. TMS R510 007 000 0071 0000 DB:194PG:405 N/F HEIRS OF HENRY SIMMONS TMS R511 007 000 068G 0000 DB:163PG:90 N/F DANIEL FRAZIER IV TMS R511 007 000 0069 0000 PB:141PG:161 DB:4052PG:2726 PICKLEBALL COURT 2.5' WOOD/ROPE FENCE 3' CHAINLINK FENCE CHAINLINK FENCE 3' WOOD FENCE S46°45'53"W 322.44' S78°18'22"E 469.62' L1 323.69' S46°46'01"W 72.42' 283.27' S46°47'40"W 313.39'(T) 30.12' L4 L3 L5 L7 L6 N46°53'22"E 661.84'(T) L9 L8 L10 L13 L12 L11 L16 L15 L20 L19 L18 L17 L14 465.24' N78°54'19"W 477.46'(T) L21 L23 L22 34.89' L26 L25 L24 338.15' ONE STORY CONCRETE SIDED BUILDING FFE:12.24' TWO STORY WOOD SIDED BUILDING FFE:16.62' TWO STORY WOOD SIDED BUILDING FFE:14.68' SHED SBA DYL DWS HOOP HOOP 3X3" CMF (BROKEN) 5X5" CMF 5X5" CMF 3X3" CMF TPED SN W C SN D C SN SN SN SN SN SN SN AR SSCO SN D TR TR TR TR FFO T F TPED W IR NEW TOILET AND STORAGE BUILDING EXISTING WATER HOSE BIBB APPROXIMATE LINE OF EXISTING TREE LINE EXISTING PARKING LOT PROPERTY LINE PROPERTY LINE NEW HANDICAPPED ACCESSIBLE PARKING SPACE - SEE CIVIL DRAWINGS NEW SIDEWALK CONNECTING PARKING AND PICKLEBALL AND TOILET FACILITIES - SEE CIVIL DRAWINGS EXISTING CONCRETE SIDEWALK LOCATION OF FEMA FLOOD LINE FEMA FLOOD LINE FEMA FLOOD LINE SEE CIVIL DRAWINGS FOR SILT FENCING, TYPICAL PROVIDE SINGLE ROW SILT FENCE AT PERIMETER OF WORK AREA IN APPROXIMATE LOCATION SHOWN (2) LOCP - LOROPETALUM CHINESE 'PURPLE DIAMOND', COMMON NAME FRINGE FLOWER, 3 GAS, 24" -36" HEIGHT, 24" -36" SPREAD (3) POMA - PODOCARPUS MACROPHYLLUS, COMMON NAME JAPANESE YEW, 15 GAL, 30" -36" HEIGHT, 24" -36" SPREAD 1. PARKING SPACES SHALL BE MARKED WITH WHITE PAINTE D LINES EXCEPT WHERE ACCESSIBILITY REQUIREMENTS REQUIRE THAT SPACES BE DELINEATED IN BLUE. 2. PAINTED YELLOW LINES SHALL BE USED FOR MARKING N O PARKING AREAS. 3. HANDICAPPED PARKING SPACE SHALL BE MINIMUM 8' WI DE X 18' LONG WITH MINIMUM 8' WIDE X 18' LONG ACCESS AISLE IMMEDIATELY TO THE PARKING SP ACE. PARKING NOTES 1. ALL TREES IN EXISTING BUFFER AREAS SHALL BE PRES ERVED. 2. WHERE GROUPINGS OF NATIVE SHRUBS ARE PRESENT IN EXISTING BUFFER AREAS THEY SHALL BE PRESERVED WITH MINIMUM DISTURBANCE.. 3. ANY CLEARING OR OTHER WORK OF ANY KIND IN EXISTI NG BUFFER AREAS MUST RECEIVE PRIOR APPROVAL OF THE APPROPRIATE TOWN OFFICIAL. 4. IN ORDER TO PRESERVE EXISTING VEGETATION AND TO RESTRICT ACTIVITIES WITHIN AN EXISTING BUFFER AREA, PROTECTIVE FENCING SHALL BE I NSTALLED IN ACCORDANCE WITH TOWN OF HHI LMO SECTION 16-6-104.J, TREE AND BUFFER PROTECTION DURING DEVELOPMENT ACTIVITIES. 5. EXISTING VEGETATION THAT IS PRESERVED SHALL NOT BE LIMBED UP FROM THE GROUND MORE THAN FIVE FEET TO THE LOWEST BRANCHES, EXCEPT: A) VEGETATION AT INTERSECTIONS MAY BE LIMBED UP TO A GREATER HEIGHT TO ENSURE COMPLIANCE WITH LMO SECTION 16-5-105.H.4, SIGHT TRIANGLES; AND B) IF UNDERSTORY PLANTING IS PROPOSED, APPROVAL MUST BE OBTAINED FROM THE APPROPRIATE TOWN OFFICIAL TO ALLOW EXISTING VEGETATION TO BE LIMBED UP TO A HEIGHT THAT WILL PR OVIDE ADEQUATE SUNLIGHT TO PLANTS. BUFFER VEGETATION NOTES 1. TREE AND BUFFER PROTECTION ZONES SHALL INCLUDE T HE AREAS OF THE DEVELOPMENT SITE THAT ARE WITHIN THE DRIP LINES OF THE INDIVIDU AL TREES AND STANDS OF TREES THAT ARE TO BE RETAINED AND PROTECTED IN ACCORDANCE WITH LMO SECTION 16-6-104.F, SPECIMEN AND SIGNIFICANT TREE PRESERVATION, SECTION 16-6-104.G, MINIMUM TREE COVERAGE STANDARD, OR SECTION 16-6-104.K, TREE DAMAGE DURING DEVELOPMENT, AS WELL AS ALL BUFFER AREAS TO BE PROTECTED IN ACCORDANCE WITH LMO SECTION 16-5-103.D, ADJACENT STREET BUFFER REQUIREMENTS AND SECTION 16-5-103.E, ADJACENT USE BUFFER REQUIREMENTS. 2. ALL BUFFER AREAS MUST BE PROTECTED WITH RED LINE SILT FENCING, INSTALLED ON METAL STAKES AND TREE PROTECTION FENCING, INCLUDING CAUTI ONARY SIGNAGE. TREE AND BUFFER PROTECT. ZONE NOTES 1. PROVIDE TO THE TOWN AN EROSION AND SEDIMENT CONT ROL PLAN PER TOWN OF HHI LMO SECTION 16-5-109.I. 2. PER TOWN OF HHI LMO SECTION 16-5-109.I.2.D, ALL EROSION, SEDIMENTATION, AND POLLUTION CONTROL BMP'S SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THE SOUTH CAROLINA DHEC'S STORMWATER BMP HANDBOOK. 3. ALL SYMBOLS AND STANDARD DETAILS SHALL CONFORM T O THOSE FOUND WITHIN THE BMP HANDBOOK. STORMWATER NOTES THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:34 PM AS-101 ARCHITECTURAL SITE PLAN 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 Author Checker Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 SCALE: 1" = 30'-0" A1 SITE PLAN TRUE NORTH PLAN NORTH ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT 11/15/2024 Town Pre-Application Submittal 3/31/2025 Town DPR Application 6/5/2025 Town DPR Revisions Page 22 of 46 FD AE -201 B4 AE -201 AE -201 A4 B1 C1 AE-201 AI -201 B5 24' - 2" 8' - 4" 1' - 6" 1' - 6" STORAGE 2 TOILET RM 1 9' - 6" 14' - 2" 6" T4 T6 T1A T2 T1A T1A T7 T1B T1C HI/LO DRINKING FOUNTAIN WITH BOTTLE FILLER - SEE PLUMBING DRWGS 2A 1A DOWNSPOUT AND CONCRETE SPLASHBLOCK DOWNSPOUT AND CONCRETE SPLASHBLOCK EDGE OF ROOF ABOVE 1' - 4" 10" 2" EQ EQ AE-601 B5 T3 SLOPE SEE STRUCTURAL DRAWINGS FOR CMU COLUMN 10" 2" 2" 2" CONCRETE PORCH SLAB TR. WOOD SILL BELOW FIBER CEMENT SIDING - FULL HEIGHT AT THIS WALL 17' - 4" 2" CONT. ALUM VENT GUTTER AND DOWNSPOUT SYSTEM - SEE SPECIFICATIONS GUTTER AND DOWNSPOUT SYSTEM 3' - 8" 3' - 8" 3' - 8" 3' - 8" DS DS OS EXPOSED RAFTER TAILS 2' - 8" 2' - 8" 2' - 8" 2' - 0" 2' - 0" EQ EQ CL 1x4 TR. WD TRIM AT PERIMETER 17 18 AE -201 B4 AE -201 AE -201 AE -201 A4 B1 A1 C1 AE-201 3:12 SLOPE 3:12 SLOPE LINE OF WALL BELOW STANDING SEAM METAL ROOF - SEE SPECIFICATIONS DS DS GUTTER AND DOWNSPOUT SYSTEM, SEE SPECIFICATIONS OS RCP LEGEND DOWN LIGHT LINEAR LED FIXTURE DUAL HEAD EMERGENCY LIGHT WALL MOUNTED LIGHT FIXTURE EXHAUST FAN OCCUPANCY SENSOR 1/2" EXTERIOR GRADE PLYWOOD FINISH WITH 1/2" X 1 1/2" BATTENS @ 4' O.C. NOTE: SEE ALSO ELECTRICAL PLANS / SCHEDULES THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:31 PM AE-101 PLANS 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 dns bht Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 SCALE: 1/4" = 1'-0" A4 FLOOR PLAN SCALE: 1/4" = 1'-0" A2 REFLECTED CEILING PLAN. SCALE: 1/4" = 1'-0" C4 ROOF PLAN. EXTERIOR MATERIAL COLOR SCHEDULE (SEE ALSO SPECIFICATIONS) SIDING SIDING TRIM (SMOOTH) WOOD STRUCTURE / CEILING TABBY STUCCO ROOF PANELS AND TRIM HARDI PLANK - TIMBER BARK HARDI PLANK - COBBLE STONE CABOTS SEMI SOLID STAIN - BEECHWOOD GRAY TO MATCH COLIGNY WATERFRONT PARK BUILDINGS PAC-CLAD - ZINC ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT TRUE NORTH PLAN NORTH TRUE NORTH PLAN NORTH TRUE NORTH PLAN NORTH 11/15/2024 Town Pre-Application Submittal 3/31/2025 Town DPR Application Page 23 of 46 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" C1 AE-201 1A BEAM - SEE STRUCTURAL TABBY STUCCO FINISH AT CMU COLUMN HI -LO DRINKING FOUNTAIN W/ BOTTLE FILLER - SEE PLUMBING DRWGS EXPOSED RAFTER TAILS GUTTER AND DOWNSPOUT SYSTEM STANDING SEAM METAL ROOF SEE SCHEDULE FOR DOOR AND FRAME SEE CIVIL DRWGS FOR FINISHED GRADE FIBER CEMENT LAP SIDING - 6" EXPOSURE T.O.M.@ COLUMN 8' - 7 3/4" DOWNSPOUT W/ CONC. SPLASH BLOCK 17 18 +/- 13' - 5 3/8" 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" C1 AE-201 STANDING SEAM METAL ROOF GUTTER AND DOWNSPOUT SYSTEM TO CONCRETE SPLASHBLOCK EXJPOSED RAFTER TAILS 1X FIBER CEMENT BD. CORNER TRIM FIBER CEMENT LAP SIDING - 6" EXPOSED TR. WD. SILL TABBY STUCCO FOUNDATION - SEE SPECIFICATIONS SEE CIVIL DRAWINGS FOR FINISHED GRADE T.O.M.@ COLUMN 8' - 7 3/4" 17 18 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" 2A TABBY STUCCO - SEE SPECS FIBER CEMENT BOARD TRIM HI/LO FOUNTAIN W/ BOTTLE FILLER - SEE PLUMBING FIBER CEMENT LAP SIDING GUTTER AND DOWNSPOUT SYSTEM CONCRETE SPLASH BLOCK FIBER CEMENT BOARD TRIM TABBY STUCCO FINISH AT CMU COLUMN SEE CIVIL DRAWINGS FOR FINISHED GRADE 3" / 12" OPEN 2' - 0" T.O.M.@ COLUMN 8' - 7 3/4" 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" AE-301 A5 AE-301 A3 2' - 8" 2' - 8" FIBER CEMENT CORNER TRIM BD SEE STRUCTURAL DRAWINGS FOR TRUSS SYSTEM STANDING SEAM METAL ROOF - SEE SPECIFICATIONS GUTTER AND DOWNSPOUT SYSTEM - SEE SPECIFICATIONS SEE STRUCTURAL DRAWINGS FOR CONCRETE SLAB AND FOUNDATION SEE CIVIL DRAWINGS FOR GRADE TABBY STUCCO FINISH AT CMU COLUMN SEE STRUCTURAL DRWGS FOR BEAM SEE DOOR SCHEDULE FOR DOOR AND FRAME T.O.M.@ COLUMN 8' - 7 3/4" 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" - --- 3" / 12" FIBER CEMENT LAP SIDING, 6" EXPOSURE TABBY BASE - SEE SPECS TR. WOOD SILL FIBER CEMENT TRIM BOARD GUTTER AND DOWNSPOUT SYSTEM TO CONCRETE SPLASH BLOCK OPEN TABBY STUCCO AT CMU COLUMN T.O.M.@ COLUMN 8' - 7 3/4" THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:32 PM AE-201 BUILDING ELEVATIONS & SECTIONS 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 kn dns Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 SCALE: 1/4" = 1'-0" A4 SOUTH BUILDING ELEVATION SCALE: 1/4" = 1'-0" A1 NORTH BUILDING ELEVATION SCALE: 1/4" = 1'-0" B1 EAST BUILDING ELEVATION SCALE: 1/4" = 1'-0" C1 BUILDING SECTION SCALE: 1/4" = 1'-0" B4 WEST BUILDING ELEVATION ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT 11/15/2024 Town Pre-Application Submittal 3/31/2025 Town DPR Application Page 24 of 46 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" FINISHED GRADE, SLOPE AWAY FROM BUILDING - SEE CIVIL DRAWINGS 10" CMU - SEE STRUCTURAL DRAWINGS AE-301 C5 TR. WOOD SILL 8" CMU - SEE STRUCTURAL DRWGS 2' - 0" EXPOSED RAFTER TAILS GUTTER AND DOWNSPOUT SYSTEM TO CONCRETE SPLASH BLOCK 1X FIBER CEMENT TRIM BOARD FASCIA 2X TR. BLOCKING METAL DRIP EDGE EXTERIOR GRADE PLYWOOD SHEATHING - SEE STRUCTURAL DRWGS STANDING SEAM METAL ROOF - SEE SPECS ROOF TRUSS - SEE STRUCTURAL DRWGS TR. 2X8'S - SEE STRUCTURAL DRWGS 1X4 TR. WD TRIM 1/2" EXTERIOR GRADE PLYWOOD WITH 1/2" X 1 1/2" BATTENS AT 4'-0" O.C. BACKER ROD AND SEALANT 2" ALUMINUM VENT BETWEEN EVERY OTHER RAFTER 1" FIBER CEMENT TRIM BOARD BETWEEN RAFTERS FIBER CEMENT BOARD LAP SIDING (6" EXPOSED) - SEE SPECIFICATIONS 2X4 FRAMING BETWEEN RAFTERS TABBY STUCCO OVER METAL LATH - SEE SPECIFICATIONS BACKER ROD AND SEALANT DRIP SCREED WEATHER BARRIER 1/2" SHEATHING ON 7/8" METAL HAT CHANNELS SEE STRUCTURAL DRAWINGS FOR SLAB AND FOUNDATION - BROOM FINISH AT SLAB 9 1/4" 3" / 12" T.O.M.@ COLUMN 8' - 7 3/4" 45.00° WATERPROOF MEMBRANE TO 15' MSL, (HENRY AQUA -BLOCK WB HE784 OR APPROVED EQUAL) - SEE ALSO SHEET S100, CONCRETE MASONRY NOTE 21 1ST FLOOR 0' - 0" TOP OF MASONRY 9' - 4" 2' - 8" ROOF TRUSS - SEE STRUCTURAL DRWGS EXTERIOR GRADE PLYWD SHEATHING - SEE STRUCTURAL DRWGS STANDING SEAM METAL ROOF - SEE SPECIFICATIONS METAL DRIP EDGE GUTTER AND DOWNSPOUT SYSTEM - SEE SPECIFICATIONS 1X FIBER CEMENT TRIM BOARD FASCIA 2X TR. BLOCKING EXPOSED RAFTER TAILS 1/2" EXTERIOR GRADE PLYWOOD W/ 1/2" X 1 1/2" BATTENS AT 4' -0" O.C. 3/4" X 3 1/2" FIBER CEMENT TRIM BOARD 1X FIBER CEMENT TRIM BOARD, TYP. TABBY STUCCO OVER METAL LATH AT CMU COLUMN BEYOND SEE STRUCTURAL DRAWINGS FOR SLAB AND FOUNDATION SEE CIVIL DRAWINGS FOR SIDEWALKS 9 1/4" 3" / 12" TR. 2X4 FRAMING BETWEEN RAFTERS T.O.M.@ COLUMN 8' - 7 3/4" 2" CONT. ALUM VENT - SEE RCP 45.00° 8" CMU - SEE STRUCTURAL DRAWINGS 7/8" METAL FURRING CHANNELS 1/2" FIBERGLASS FACED GYP SHEATHING WEATHER BARRIER FIBER CEMENT LAP SIDING - SEE SPECIFICATIONS FLASHING TR. WOOD SILL W/ DRIP EDGE FLASHING - TURN UP BEHIND WEATHER BARRIER 8" MIN TABBY STUCCO SYSTEM - SEE SPECIFICATIONS 10" CMU - SEE STRUCTURAL DRAWINGS BACKER ROD AND SEALANT 3" 1" 2" 3" WATERPROOF MEMBRANE TO 15' MSL - SEE A5/AE -301 THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:32 PM AE-301 SECTIONS / DETAILS 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 kn dns Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 SCALE: 3/4" = 1'-0" A5 WALL SECTION SCALE: 3/4" = 1'-0" A3 SECTION AT COLUMN/BEAM SCALE: 3" = 1'-0" C5 SILL DETAIL ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT 3/31/2025 Town DPR Application Page 25 of 46 F SEE MECH PLAN FOR VENT SIZE 0' - 10" MIN. 6" MIN 6" MIN (PR) F HM -1 7' - 0" 4" 2" 3' - 0" 2" 3' - 4" 7' - 4" HM -2 7' - 0" 4" 2" 6' - 0" 2" 6' - 4" 7' - 4" MIN 6" MIN 6" 6" MIN 6" TO BASELINE OF BRAILLE CELLS 48" MIN / 60" MAX FINISH FLOOR PICTOGRAM, IF APPLICABLE TEXT/BRAILLE - ADJUST SIZE ACCORDING TO LETTERING SIGN LOCATION: SINGLE DOOR - AT LATCH SIDE DOUBLE DOOR - AT RIGHT SIDE OF RIGHT HAND DOOR NOTE: ADJUST SIZE OF SIGN FOR LARGE PICTOGRAMS AND/OR LETTERING THAT WILL NOT FIT ON STANDARD MIN. SIZE. EDGE OF DOOR FRAME HARDWARE SCHEDULE SET 1 - PRIVACY QTY. DESCRIPTION CAT. NUMBER MFR. 3 EA 1 EA 1 EA 1 EA 1 EA 1 EA 3 EA 1 EA 1 EA HINGE MORTISE LOCK SURFACE CLOSER PUSH PLATE PULL KICK PLATE SILENCER DOOR SWEEP GASKETING 5BB1 4.5 X 4.5 ML2055 LWA GMK 4011 120L CFC 8303 4" X 16" CFT 8400 8" X 34" LDW B -CS SR64 39A 188S PSA IVES OR APPROVED EQUAL CORBIN -RUSSWIN OR APPROVED EQUAL LCN OR APPROVED EQUAL HAGER OR APPROVED EQUAL IVES OR APPROVED EQUAL IVES OR APPROVED EQUAL IVES OR APPROVED EQUAL ZERO OR APPROVED EQUAL ZERO OR APPROVED EQUAL SET 2 - STORAGE QTY. DESCRIPTION CAT. NUMBER MFR. 6 EA 2 EA 1 EA 1 EA 1 EA 2 EA 1 EA HINGE FLUSH BOLT LOCKSET RAIN DRIP DOOR SEAL DOOR SWEEP THRESHOLD 5BB1 4.5 X 4.5 FB458 ML2057 LWA CMK MK VKC2 142AA 76" 188SBK 1 X 72" / 2 X 84" 39A 36" 655A 72" 223 -MSLA -10 IVES OR APPROVED EQUAL IVES OR APPROVED EQUAL CORBIN -RUSSWIN OR APPROVED EQUAL ZERO OR APPROVED EQUAL ZERO OR APPROVED EQUAL ZERO OR APPROVED EQUAL ZERO OR APPROVED EQUAL DOOR - SEE SCHEDULE DOOR FRAME W/ MASONRY ANCHOR - GROUT SOLID - SEE DOOR SCHEDULE 8" CMU - SEE STRUCTURAL - PROVIDE 8" OF SMOOTH FACED CMU AT FLOOD PROTECTION JAMB TRACK - MATCH COLOR OF ADJACENT CMU 1" 5 3/4" EQ SEALANT W/ BACKER ROD 1X FIBER CEMENT BOARD TRIM FIBER CEMENT BOARD LAP SIDING OVER 1/2" SHEATHING ON 7/8" METAL HAT CHANNELS TR. WD. BLOCKING LINE OF TABBY WALL BELOW LINE OF TR. WD SILL BELOW 1" X 5 1/2" FIBER CEMENT BD TRIM WATERPROOF MEMBRANE - SEE A5/AE -301 SEALANT EA SIDE 7 1/4" EQ DOOR - SEE SCHEDULE DOOR FRAME W/ MASONRY ANCHOR - GROUT SOLID - SEE DOOR SCHEDULE SEALANT EA SIDE 8" CMU - SEE STRUCTURAL - PROVIDE 8" OF SMOOTH FACED CMU AT FLOOD PROTECTION JAMB TRACK - MATCH COLOR OF ADJACENT CMU SEALANT W/ BACKER ROD 1X FIBER CEMENT BOARD TRIM SEALANT W/ BACKER ROD TABBY STUCCO SYSTEM - SEE SPECIFICATIONS LINE OF TR. WD SILL ABOVE 10" CMU - SEE STRUCTURAL DRWGS WATERPROOF MEMBRANE - SEE A5/AE -301 SEE STRUCTURAL DRAWINGS FOR FLOOR SLAB ALUMINUM THRESOLD SET IN BED OF SEALANT DOOR FRAME BEYOND - SEE SCHEDULE DOOR - SEE SCHEDULE EMBEDDED SILL ANGLE BY FLOOD PROTECTION MFR. - SEE ALSO STRUCTURAL DRWGS - GENERAL CONTRACTOR TO COORDINATE REMOVABLE ALUMINUM FLOOD PLANK SILL GASKET BY FLOOD PROTECTION MFR. DOOR SWEEP AS SCHEDULED 0' - 4" 0' - 4" CONCRETE STOOP - SEE PLAN; SLOPE TO DRAIN 1/2" EXPANSION MATERIAL SEE STRUCTURAL DRAWINGS FOR FLOOR SLAB ALUMINUM THRESOLD SET IN BED OF SEALANT DOOR FRAME BEYOND - SEE SCHEDULE DOOR - SEE SCHEDULE EMBEDDED SILL PLATE BY FLOOD PROTECTION MFR. - GENERAL CONTRACTOR TO COORDINATE REMOVABLE ALUMINUM FLOOD PLANK SILL GASKET BY FLOOD PROTECTION MFR. DOOR SWEEP AS SCHEDULED 0' - 4" 8" CMU - SEE STRUCTURAL DRAWINGS SEALANT BOTH SIDES DOOR - SEE SCHEDULE DOOR FRAME - GROUT SOLID - SEE DOOR SCHEDULE CMU LINTEL - SEE STRUCTURAL EQ 1/2" SHEATHING ON 7/8" HAT CHANNELS FLASHING - EXTEND UP BEHIND WEATHER BARRIER 8" MIN. SEALANT BACKER ROD AND SEALANT FIBER CEMENT BOARD LAP SIDING - 6" EXPOSED 1X FIBER CEMENT BOARD TRIM 1" X 5 1/2" FIBER CEMENT BD TRIM DOOR - SEE SCHEDULE DOOR FRAME W/ MASONRY ANCHOR - GROUT SOLID - SEE DOOR SCHEDULE SEALANT EA SIDE 10" CMU - SEE STRUCTURAL EQ 1" X 5 1/2" FIBER CEMENT BOARD TRIM SEALANT W/ BACKER ROD FIBER CEMENT BOARD LAP SIDING OVER 1/2" SHEATHING ON 7/8" METAL HAT CHANNELS TR. WD. BLOCKING 1X FIBER CEMENT BOARD TRIM WATERPROOF MEMBRANE - SEE A5/AE -301 THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE NOT FOR CONSTRUCTION Drawing DATE DESCRIPTION ∆ THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M C Y K ARCHITECT Project Number: Drawn By: Checked By: © Hord Coplan Macht, Inc. A B C D 1 2 3 4 5 6/17/2025 12:49:33 PM AE-601 DOOR SCHEDULE & DETAILS 152 William Hilton Parkway Hilton Head Island, South Carolina, 29926 Old Schoolhouse Park Toilet Facility Town of Hilton Head Island CIVIL ENGINEER 1536 Fording Island Road STRUCTURAL ENGINEER 110 Traders Cross, Second Floor MECHANICAL AND PLUMBING ENGINEER 110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00 kn dns Issue Date NOVEMBER 15, 2024 ELECTRICAL ENGINEER P.O. Box 2869 CDDC Bluffton, SC 29910 843.384.4731 Door Schedule Mark Door Type Thickness Width Height Material Finish Frame Type Frame Material Frame Finish Head Detail Jamb Detail Sill Detail Hardware Set Signage Comments 1A F 0' - 1 3/4" 3' - 0" 7' - 0" Steel Paint HM-1 HM Paint C5 /AE-601 B2/AE-601 A4/AE-601 1 X Provide ADA/ANSII compli ant pictogram signage for HC accessible unisex toilet. See detail this sheet. 2A (PR) F 0' - 1 3/4" 6' - 0" 7' - 0" Steel Paint HM-2 HM Pa int C5/AE-601 B4/AE-601 / B5/AE-601 A5/AE-601 2 X SCALE: 1/4" = 1'-0" C3 DOOR/FRAME ELEVATIONS SCALE: 1/2" = 1'-0" A1 SIGN MTG DTL SCALE: 3" = 1'-0" B5 DOOR JAMB DETAIL AT SIDING SCALE: 3" = 1'-0" B4 DOOR JAMB DETAIL AT TABBY SCALE: 3" = 1'-0" A5 DOOR SILL DETAIL SCALE: 3" = 1'-0" A4 DOOR SILL DETAIL AT TLT. SCALE: 3" = 1'-0" C5 DOOR HEAD DETAIL SCALE: 3" = 1'-0" B2 DOOR JAMB DETAIL AT TLT. ARCHITECTURE LANDSCAPE ARCHITECTURE PLANNING INTERIOR DESIGN 10 PALMETTO BUSINESS PARK HILTON HEAD ISLAND, SC 29928 843.785.2199 HORD COPLAN MACHT 3/31/2025 Town DPR Application Page 26 of 46 FDFD THE LINE SHOWN ABOVE ISEXACTLY ONE INCH LONG AT THISSHEETS ORIGINAL PAGE SIZE FOR PERMIT Drawing DATEDESCRIPTION¨ THE SQUARES ABOVE ARE COLOR, WITH BLACKAND WHITE LETTERS, IF PRINTED CORRECTLYMCYK ARCHITECT Project Number:Drawn By:Checked By: ‹+RUG&RSODQ0DFKW,QF A B C D 12345 1/16/2025 4:10:39 PM 152 William Hilton ParkwayHilton Head Island, South Carolina, 29926 Old Schoolhouse ParkToilet FacilityTown of Hilton Head Island CIVIL ENGINEER1536 Fording Island RoadSTRUCTURAL ENGINEER110 Traders Cross, Second FloorMECHANICAL AND PLUMBING ENGINEER110 Holcomb Street STURRE ENGINEERING SHEARLOCK ENGINEERING ISLANDS ENGINEERING Hilton Head Island, SC 29926 Okatie, SC 29909 Savannah, GA 31406 843.929.9432 843.473.8767 912.356.9035 224253.00------ Issue DateNOVEMBER 20, 2024 ELECTRICAL ENGINEERP.O. Box 2869CDDC, LLCBluffton, SC 29910843.384.4731 ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN 10 PALMETTO BUSINESS PARK+,/721+($',6/$1'6&843.785.2199HORD COPLAN MACHT DESIGNDRAFTCONSULTCONSTRUCT E-100ELECTRICAL PLANS ANDDETAILS Page 27 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility 150 & 152 William Hilton Parkway Design Review Board (DRB) Photographs of Existing Facility New Building will Match View of existing facility on Cordillo Parkway that new building will match. View of existing facility on Cordillo Parkway that new building will match. Page 28 of 46 New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility Design Review Board (DRB) Photographs of Existing Facility New Building will Match Page 2 of 2 View of existing facility on Cordillo Parkway that new building will match. View of existing facility on Cordillo Parkway that new building will match. Page 29 of 46 Page 30 of 46 XTOR CROSSTOUR LED APPLICATIONS: WALL / SURFACE POST / BOLLARD LOW LEVEL FLOODLIGHT INVERTED SITE LIGHTING Lumark SPECIFICATION FEATURES Construction Slim, low-profile LED design with rugged one-piece, die-cast aluminum hinged removable door and back box. Matching housing styles incorporate both a small and medium design. The small housing is available in 12W, 18W and 26W. The medium housing is available in the 38W model. Patented secure lock hinge feature allows for safe and easy tool-less electrical connections with the supplied push-in connectors. Back box includes three half-inch, NPT threaded conduit entry points. The universal back box supports both the small and medium forms and mounts to standard 3-1/2” to 4” round and octagonal, 4” square, single gang and masonry junction boxes. Key hole gasket allows for adaptation to junction box or wall. External fin design extracts heat from the fixture surface. One- piece silicone gasket seals door and back box. Minimum 5” wide pole for site lighting application. Not recommended for car wash applications. Optical Silicone sealed optical LED chamber incorporates a custom engineered mirrored anodized reflector providing high-efficiency illumination. Optical assembly includes impact-resistant tempered glass and meets IESNA requirements for full cutoff compliance. Available in seven lumen packages; 5000K, 4000K and 3000K CCT. Electrical LED driver is mounted to the die-cast housing for optimal heat sinking. LED thermal management system incorporates both conduction and natural convection to transfer heat rapidly away from the LED source. 12W, 18W, 26W and 38W series operate in -40°C to 40°C [-40°F to 104°F]. High ambient 50°C models available. Crosstour luminaires maintain greater than 89% of initial light output after 72,000 hours of operation. Three half-inch NPT threaded conduit entry points allow for thru-branch wiring. Back box is an authorized electrical wiring compartment. Integral LED electronic driver is standard 0-10V dimming. 120-277V 50/60Hz or 347V 60Hz models. Finish Crosstour is protected with a Super durable TGIC carbon bronze or summit white polyester powder coat paint. Super durable TGIC powder coat paint finishes withstand extreme climate conditions while providing optimal color and gloss retention of the installed life. Options to meet Buy American and other domestic preference requirements. Warranty Five-year warranty. The patented Lumark Crosstour™ LED Wall Pack Series of luminaries provides an architectural style with super bright, energy efficient LEDs. The low-profile, rugged die-cast aluminum construction, universal back box, stainless steel hardware along with a sealed and gasketed optical compartment make the Crosstour impervious to contaminants. The Crosstour wall luminaire is ideal for wall/surface, inverted mount for façade/canopy illumination, post/bollard, site lighting, floodlight and low level pathway illumination including stairs. Typical applications include building entrances, multi-use facilities, apartment buildings, institutions, schools, stairways and loading docks test. DESCRIPTION 12W, 18W, 26W 5-3/4" [146mm] 38W 6-5/8" [168mm] 12W, 18W, 26W 6-3/4" [171mm] 38W 8" [203mm] 12W, 18W, 26W 3-5/8" [92mm] 38W 4" [102mm] DIMENSIONS CERTIFICATION DATA Dark Sky Approved (Fixed mount, Full cutoff, and 3000K CCT only) UL/cUL Wet Location Listed LM79 / LM80 Compliant ROHS Compliant ADA Compliant NOM Compliant Models IP66 Ingressed Protection Rated Title 24 Compliant DesignLights Consortium® Qualified* TECHNICAL DATA 40°C Maximum Ambient Temperature External Supply Wiring 90°C Minimum EPA Effective Projected Area (Sq. Ft.): XTOR1B, XT0R2B, XT0R3B=0.34 XTOR4B=0.45 SHIPPING DATA: Approximate Net Weight: 3.7 – 5.25 lbs. [1.7 – 2.4 kgs.] 10" [254mm] 17-1/2" [445mm] 10" [254mm] 17-1/2" [445mm] ESCUTCHEON PLATES *www.designlights.org Catalog # Type Date Project Comments Prepared by TD514013EN December 14, 2021 5:27 PM AVAIL ABLE COMPLIANT OPTIONS BAA BUY AMERICAN ACT Fixture B Page 31 of 46 Project Catalog # Type Prepared by Notes Date PS51889024 page 1 April 1, 2025 5:22 PM Top Product Features • Round 5"/6" Recessed LED Trims suitable for new construction, remodel, and retrofit installation in most 5" or 6" IC (insulation contact) or non-IC housings • Lens & Trim: Recessed baffle or smooth splay trims with smooth flat diffuse lens • 5-Color Field-SeleCCTable: 2700K, 3000K, 3500K, 4000K, 5000K; 90+ CRI • Brightness: 750 or 1200 lumen versions (nominal) • Dimming: Dims to 10% (phase cut LE/TE); 120V input • Includes preinstalled torsion springs, orange LED Quick Connect and E26 medium socket adapter • Meets AIR-TITE and code compliance for additional energy savings • Life: 35,000 hrs of maintenance-free operation in damp or wet locations • 5-year warranty Interactive Menu • Order Information page 2 • Product Specifications page 3 • Energy Data page 3 • Photometric Data page 4 • Product Warranty • Dimming Guide LT56 5"/6" Recessed LED Trims These L T LED Trims are ideal for quickly installing energy-saving downlighting in 5" and 6" recessed housings. The L T Series offers 5-color seleCCTable™ technology with flicker-free dimming to 10%. The safe, non-conductive dead-front trims come in baffle or smooth splay options. Decorative overlays are also available in 4 finishes. Typical Applications Residential Dimensional and Mounting Details Installs in 5" or 6" housings Package includes: E26 Screw Base Adapter L T56 L T56 High-Lumen LT56 DOB - 750 Lumen LT56 - 1200 Lumen FIXTURE HEIGHT 3.41" [86 mm] TRIM FLANGE ø 7.19" [182.67 mm] FIXTURE HEIGHT 2.18" [55.40 mm] LENS REGRESSION 0.74" [18.76 mm] LENS REGRESSION 0.76" [19.40 mm] LT56 - LT56 - Baffle LT56 DOB - 750 Lumen LT56 - 1200 Lumen FIXTURE HEIGHT 3.41" [86 mm] TRIM FLANGE ø 7.19" [182.67 mm] FIXTURE HEIGHT 2.18" [55.40 mm] LENS REGRESSION 0.74" [18.76 mm] LENS REGRESSION 0.76" [19.40 mm] TRIM FLANGE 7.22" [183 mm] LT56 LT56 - Baffle L T56 -750 Lumen L T56 -1200 Lumen TRIM FLANGE ø 7.19" [182.67 mm] FIXTURE HEIGHT 2.18" [55.40 mm] APERTURE OPENING ø 4.88" [124 mm] APERTURE OPENING ø 4.85" [123 mm] LT56 - Baffle LTSS56 - Smooth Splay LT56 - Baffle LTSS56 - Smooth Splay Can be used to comply with Title 24 Part 6 LED Enclosed Light Source Requirements (JA8) Refer to ENERGY STAR® Certified Products List. Can be used to comply with California Title 24 High Efficacy requirements.(1) Certified to California Appliance Efficiency Database under JA8.(1) DEAD FRONT 1. T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification. Fixture C Page 32 of 46 LT56 5"/6" Recessed LED Trims PS51889024 page 2 April 1, 2025 5:22 PM Order Information A complete downlight consists of an integrated LED trim and a recessed housing (order separately). Catalog Number Module Lumens CRI/CCT Finish Packaging L T56079FS1EWHR 5/6 inch LED retrofit module with baffle trim 750 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White Recyclable L TSS56079FS1EWHR 5/6 inch LED retrofit module with smooth splay trim 750 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White Recyclable L T56129FS1EWHR 5/6 inch LED retrofit module with baffle trim 1200 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White Recyclable L TSS5612FS1EWHR 5/6 inch LED retrofit module with smooth splay trim 1200 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White Recyclable Catalog Number Module Lumens CRI/CCT Finish Packaging L T56079FS1EWHR4PK 5/6-inch Recessed Baffle LED Trim 750 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White 4 pack, Recyclable L T56079FS1EWHR6PK 5/6-inch Recessed Baffle LED Trim 750 lumen 90+ CRI, field selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K Matte White 6 pack, Recyclable Optional Accessories - Decorative Baffle Trim Overlays (sold separately) Catalog Number Description L T56OMWB 5/6-inch Overlay, Paintable Matte White L T56OMBB 5/6-inch Overlay, Matte Black L T56OSNB 5/6-inch Overlay, Satin Nickel L T56OTBZ 5/6-inch Overlay, Tuscan Bronze HE26LED Replacement medium E26 screw base adapter (1 is already included with unit) ML7RAB Retrofit Adapter Band – use with existing 5" & 6" housings that do not have torsion spring receivers Multi-packs Individuals L T56OMWB White (Paintable), Baffle L T56OMBB Matte Black, Baffle L T56OSNB Satin Nickel, Baffle L T56OTBZ Tuscan Bronze, Baffle HALO - 6" Housings 1 HALO LED H750ICAT, H750RICAT, H750T, H750TCP , H2750ICAT, H2750RICAT, H550ICAT, H550RICAT, E550ICAT, E550RICAT, E750ICAT, E750RICAT Standard Housing H7ICAT, H7ICT, H7T, H7ICATNB, H7ICTNB, H7TNB, H7UICAT, H7TCP , H7RICAT, H7RICT, H7RT, E7ICAT, E7ICATNB, E7RICAT, E7RTAT, E7TAT, E7TATNB, H7UICAT, H7ICATNB, H7ICTNB, H7TNB, H7UICAT Shallow Housing H27ICAT, H27RICAT, H27ICT, H27RICT, H27T, H27RT, EI2700AT, EI2700, EI2700R, ET2700, ET2700R, E27ICAT, E27RICAT, E27TAT, E27RTAT Fire Rated Housing H750FR2ICATD010 HALO - 5" Housings 1 Halo LED H550ICAT, H550RICAT, E550ICAT, E550RICAT Standard Housing H5ICAT, H5ICATNB, H5RICAT, H5T, H5TNB, H5RT, E5ICAT, E5ICATNB, E5RICAT, E5RTAT, E5TAT, E5TATNB Shallow Housing H25ICAT, H25RICAT, H25ICATNB Fire Rated Housing H550FR2ICATD010 Juno Standard Housing IC22, IC22R, IC22W, IC22S, IC23, IC23W, TC2, TC2R, IC2 Shallow Housing IC21, IC21R Capri Standard Housing CR1, PR1, QL1 Shallow Housing R9ASIC/PS9RM Elco HL7ICA (EL7ICA) Thomas PS1 Commercial Electric C7ICA, H3 LUMINAIRES - UL Classified for retrofit compatibility ote: N Compatible with any 5" or 6" diameter recessed luminaire with an internal volume that exceeds 115 in 3 in addition to those listed below. Compatible Housings Lithonia Lighting Standard Housing LC6, L7X Shallow Housing L7XP Progress Lighting Standard Housing P87-AT† * Shallow Housing P86TG Lightolier 1104ICS† *, 1104ICR† * 1. This fixture is UL Certified for use with any 5" or 6" diameter recessed luminaire constructed of steel or aluminum with an internal volume that exceeds 107.9 in 3 addition to those noted below and does not exceed the input rating of the luminaire. Page 33 of 46 LT56 5"/6" Recessed LED Trims PS51889024 page 3 April 1, 2025 5:22 PM Specification Features Module • The LED module consists of an LED array, optical assembly, driver, and self-flanged trim • Round recessed baffle or smooth splay trim and smooth flat lens • Integral aluminum heat sink provides passive thermal cooling achieving L70 at 35,000 hrs in IC (insulation contact) and non-IC applications LED Array • Color Temperature (CCT): Available in 5-color seleCCTable CCT: 2700K, 3000K, 3500K, 4000K, 5000K (soft white, bright white, neutral white, cool white, daylight) • Mid-power LED array provides a uniform light source with high efficiency, long life, and no pixilation • 90+ CRI minimum, R9 greater than 50 • Color accuracy at 4 SDCM in between endpoints provides color consistency and uniformity Optical Assembly • Optical assembly provides wide light distribution – useful for general area and task lighting • Diffuse injection molded lens with smooth flat profile • Meets ENERGY STAR® color angular uniformity requirements Driver • Integral 120V 60Hz constant current driver provides noise-free, high-efficiency operation • Dimmable: Continuous, flicker-free dimming from 100% to 10% with compatible leading or trailing edge (LE/TE) 120V phase cut dimmers. (See Dimming Guide for compatible dimmers.) Tip: For optimal dimming performance, consider dimmers with low-end trim adjustment; note that some dimmers require a neutral wire in the box • Wiring: Includes inline electrical orange LED Quick Connect and E26 medium socket adapter provides mains connections • A separate ground wire and mounting hardware ensures proper ground connection to housing Retention • Preinstalled steel torsion springs hold the module securely in the housing (requires torsion spring receivers) • Ships with torsion springs in the 6" position, adjusts to 5" position with two Phillips-head screws Trim • The one-piece step baffle or smooth splay and self-flanged trim ring provide lens regression and reduced light leaks • Injection molded plastic construction is impact- resistant and non-corrosive • Non-conductive construction meets most local dead-front code requirements Gasket • Due to the HALO L T/L TE design, a gasket is not required to achieve AIR-TITE code requirements (caulking can be used for additional sealing if necessary for local code) Compliance • UL Certified for US and Canada, type IC suitable for UL-Certified for US and Canada, type IC suitable for direct contact with air permeable insulation • UL-Certified for US and Canada for use with HALO housings, classified for use with others’ housings; see instruction sheet for conditions of acceptability • Wet location-listed and IP66 ingress protection- rated • Airtight per ASTM-E283 • Suitable for use in clothes closets when installed in accordance with the NEC 410.16 spacing requirements • EMI/RFI emissions per FCC47CFR Part 15 consumer limits • Contains no mercury or lead and is RoHS compliant¹ • Photometric testing in accordance with IES LM-79-08 • Lumen maintenance projections in accordance with IES LM-80-08 and TM-21-11 • Can be used for State of California Title 24 high- efficacy luminaire compliance; reference the California Energy Commission Title 20 Appliance Efficiency Database for current listings¹ • ENERGY STAR® listed; reference database for current listings • Meets State of California voluntary lamp standards • Lighting Facts labeled Warranty • Five year limited warranty, consult website for details. www.cooperlighting.com/warranty Energy Data LT56 DOB - 750 Lumen LT56 - 1200 Lumen Lumens 750LM Input Voltage 120V Input current 0.065A Input Power 8.75W Efficiency 63.50% Inrush(A) 3.74 THD 25.70% PF 0.966 T Ambient -30 - +40°C Sound Rating 18.024dB @1feet Lumens 1200LM Input Voltage 120V Input current 0.105A Input Power 12.4W Efficiency 84.00% Inrush(A) 2.9 THD 14.50% PF 0.97 T Ambient -30 - +40°C Sound Rating 20.2db@30cm 1. T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification. Page 34 of 46 LT56 5"/6" Recessed LED Trims PS51889024 page 4 April 1, 2025 5:22 PM Photometric Data 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 365 274 183 91 0 LT56079FS1EWHR_3000K Spacing Criteria (0/90/45): 1.17 / 1.17 / 1.27 Beam Angle: 95.7O Field Angle: 141.4O Lumens: 795 Input Watts: 8.6 W Efficacy: 92.4 LPW UGR: 22.6 Test Report: P798568 Zonal Lumen Lumens % Lumens 0-30 273.2 34.4 0-40 435.2 54.7 0-60 708.2 89.1 0-90 794.1 99.9 TM-30-15 Rf = 92 Rg = 101 CRI/CIE Ra = 93 R9 = 83.2 94° CCT - Range of 2700K- 5000K Lumens 795 Watts 8.6 Lumens Per Watt (Efficacy) 92.4 Color Accuracy (CRI) 93 PRODUCT SPECIFICATIONS 2700K 3000K 4500K 6500K Light Color (CCT) 3000K Correlated Color Temperature (CCT) warm white soft white bright white LT56079FS1EWHR_3000KLT56 5CCT CCT Watts lumens LPW CRI 2700K 8.5 760 89.4 93 3000K 8.6 795 92.4 93 3500K 8.0 790 98.8 93 4000K 8.5 795 93.5 93 5000K 8.0 780 97.5 93 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 364 273 182 91 0 LTSS56079FS1EWHR_3000K Spacing Criteria (0/90/45): 1.17 / 1.17 / 1.26 Beam Angle: 94.8O Field Angle: 141.6O Lumens: 789.7 Input Watts: 8.7 W Efficacy: 90.8 LPW UGR: 22.7 Test Report: P798563 Zonal Lumen Lumens % Lumens 0-30 273.4 34.6 0-40 434.2 55.0 0-60 703.1 89.0 0-90 788.9 99.9 TM-30-15 Rf = 92 Rg = 101 CRI/CIE Ra = 93 R9 = 83.4 94° CCT - Range of 2700K- 5000K Lumens 790 Watts 8.7 Lumens Per Watt (Efficacy) 90.8 Color Accuracy (CRI) 93 PRODUCT SPECIFICATIONS 2700K 3000K 4500K 6500K Light Color (CCT) 3000K Correlated Color Temperature (CCT) warm white soft white bright white LTSS56079FS1EWHR_3000KLT56 5CCT CCT Watts lumens LPW CRI 2700K 8.5 770 90.6 93 3000K 8.7 790 90.8 93 3500K 8.0 810 101.3 93 4000K 8.5 810 95.3 93 5000K 8.5 790 92.9 93 Page 35 of 46 LT56 5"/6" Recessed LED Trims Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P : 770-486-4800 www.cooperlighting.com © 2025 Cooper Lighting Solutions All Rights Reserved. Specifications and dimensions subject to change without notice. PS51889024 page 5 April 1, 2025 5:22 PM 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 536 402 268 134 0 LT56129FS1EWHR-3000K Spacing criterion: (0-180) 1.22 | (90-270) 1.20 | (Diagonal) 1.28 Beam Angle: 92.9° Field Angle: 93.6° Lumens: 1127 Input Watts: 12 W Efficacy: 94 LPW UGR: 21.5 Test Report: P600898 Zonal Lumen Lumens % Lumens 0-30 405.9 36 0-40 646.3 57.3 0-60 1019.8 90.5 0-90 1123.7 99.7 TM-30-15 Rf = 92 Rg = 103 CRI/CIE Ra = 96.5 R9 = 85.2 93° CCT - Range of 2700K- 5000K 22CZ2-24-UNVL830-CD1-U Electronic Driver Linear LED 5000K Spacing criterion: (II) 1.23 x mounting height, (⊥) 1.23 x mounting height Lumens: 11493 Input Watts: 87.7W Efficacy: 131.1 LPW Test Report: 22CZ2-24-UNVL830- CD1-U.IES 0-deg 45-deg 90-deg 180° 170°160° 150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° 536 402 268 134 0 LTSS5612FS1EWHR-3000K Spacing criterion: (0-180) 1.22 | (90-270) 1.20 | (Diagonal) 1.28 Beam Angle: 92.9° Field Angle: 93.6° Lumens: 1127 Input Watts: 12 W Efficacy: 94 LPW UGR: 21.5 Test Report: P600898 Zonal Lumen Lumens % Lumens 0-30 405.9 36 0-40 646.3 57.3 0-60 1019.8 90.5 0-90 1123.7 99.7 TM-30-15 Rf = 92 Rg = 103 CRI/CIE Ra = 96.5 R9 = 85.2 93° CCT - Range of 2700K- 5000K Lumens 1345 Watts 12.2 Lumens Per Watt (Efficacy) 110.2 Color Accuracy (CRI) 93 PRODUCT SPECIFICATIONS 2700K 3000K 4500K 6500K Light Color (CCT) 3000K Correlated Color Temperature (CCT) warm white soft white bright white LT56129FS1EWHR-3000K Lumens 1345 Watts 12.2 Lumens Per Watt (Efficacy) 110.2 Color Accuracy (CRI) 93 PRODUCT SPECIFICATIONS 2700K 3000K 4500K 6500K Light Color (CCT) 3000K Correlated Color Temperature (CCT) warm white soft white bright white LTSS5612FS1EWHR-3000K LT56 5CCT CCT Watts lumens LPW CRI 2700K 12.7 1230 96.9 93 3000K 12.2 1345 110.2 93 3500K 12.1 1385 114.5 93 4000K 12.3 1380 112.2 93 5000K 12.6 1290 102.4 93 LT56 5CCT CCT Watts lumens LPW CRI 2700K 12.7 1230 96.9 93 3000K 12.2 1345 110.2 93 3500K 12.1 1385 114.5 93 4000K 12.3 1380 112.2 93 5000K 12.6 1290 102.4 93 Page 36 of 46 Project Catalog # Type Prepared by Notes Date TD505137EN page 1 June 23, 2020 8:25 AM Top Product Features • Long life LED source with rotatable optics • Labor-saving automatic self-diagnostic for NFPA testing • 29 feet to 50 feet of emergency egress coverage • UL924 listed for wet location; NYC and Chicago Compliant • Multi-voltage input 120/240/277 VAC • Mullion-mount option Interactive Menu • Order Information page 2 • Photometric Data page 2 • Product Warranty Dimensional Details additional product diagrams Typical Applications Office • Education • Healthcare • Hospitality • Retail • Industrial Sure-Lites SELDWA Emergency Light LED Emergency Light Wet Location AccuLED Optic Self Diagnostics Black Silver White Bronze Product Certification Product Features 7 .9375" [202mm] 7 .875" [200mm] 2.1875" [56mm] operating temperature range Fixture OEM Page 37 of 46 SELDWA Emergency Light TD505137EN page 2 June 23, 2020 8:25 AM Ordering Information SAMPLE ORDER NUMBER: SELW25BZ Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog SELD W=Wet location. __=0 C to 40 C A=Architectural 50=50 ft. __=Silver BZ=Bronze BK=Black WH=White SD=self diagnostics (standard) SELDWA50SD SELDWA50BZSD SELDWA50BKSD SELDWA50WHSD Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog SELD W=Wet location. T=-20 C to 55 C A=Architectural 29=29 ft. __=Silver BZ=Bronze BK=Black WH=White SD=self diagnostics (standard) SELDWTA29SD SELDWTA29BZSD SELDWTA29BKSD SELDWTA29WHSD Product Specifications Electrical • Dual Voltage Input 120/277 VAC, 60Hz • Brownout circuit • Low voltage disconnect • Overload / Short Circuit protection • 4.8V Battery back-up • 100 Lumen LED = 1.1 watts • 300 Lumen LED = 4.1 watts Environmental • Outdoor rated • SELDWA50: 0 °C to 40 °C (32 °F to 104 °F) • SELDWTA29: -20 °C to 55 °C (-4 °F to 131 °F) Housing Construction • Die cast aluminum housing • White, black, silver, or bronze textured finish • Snap-fit construction to facilitate fast installation • Suitable for wall mount or conduit mount applications • Universal J-box mounting pattern • Keyhole mounting slots • Aesthetically designed with a thin profile • Sealed and gasketed for Wet Location use Battery • Sealed Nickel Cadmium • Full Recharge Time, 24 hours (max.) • Mullion-mount option enabled with the SELDWAMMKIT accessory Warranty • Five-year warranty • Seven year pro-rated battery warranty Code Compliance • UL924 Wet Location Listed • Life Safety NFPA 101 • NEC/OSHA • Most State & Local Codes • California Energy Code • NYC compliant • SELDWA50 series is City of Chicago compliant Accessory SELDWAMMKIT enables mullion mounting and is ordered separately. Electrical Data 120V 277V Model Power (W) Current (A) PF Power (W) Current (A) PF All Models 2.0 0.3 0.07 1.8 0.21 0.03 Photometry X Y Z Orient Tilt Roll -0.25 0.5 7.5 90 7 1 0.25 0.5 7.5 90 7 -1 28.75 0.5 7.5 90 7 1 29.25 0.5 7.5 90 7 -1 57.75 0.5 7.5 90 7 1 58.25 0.5 7.5 90 7 -1 -29.25 0.5 7.5 90 7 1 -28.75 0.5 7.5 90 7 -1 SELDWTA29 calc grid in between fixtures Illuminance (Fc) Average = 1.03 Maximum = 1.5 Minimum = 0.2 Avg/Min Ratio = 5.15 Max/Min Ratio = 7.50 Spacing Stat Area calc grid in between fixtures Illuminance (Fc) Average = 1.03 Maximum = 1.5 Minimum = 0.2 Avg/Min Ratio = 5.15 Max/Min Ratio = 7.50 Spacing Stat Area 29ft Arrangement Total Lamp Lumens LLF Description SINGLE N.A. 0.912 LEM X Y Z Orient Tilt Roll -0.25 0.5 7.5 90 7 1 0.25 0.5 7.5 90 7 -1 28.75 0.5 7.5 90 7 1 29.25 0.5 7.5 90 7 -1 57.75 0.5 7.5 90 7 1 58.25 0.5 7.5 90 7 -1 -29.25 0.5 7.5 90 7 1 -28.75 0.5 7.5 90 7 -1 1.19 1.05 0.76 0.47 0.28 0.23 0.28 0.46 0.76 1.04 1.22 1.21 1.11 1.12 1.13 1.10 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.10 1.11 1.13 1.13 1.12 1.24 1.24 1.06 0.77 0.47 0.28 0.22 0.27 0.47 0.76 1.07 1.17 1.20 1.24 1.20 1.16 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.12 1.15 1.18 1.19 1.17 1.21 1.08 0.76 0.47 0.27 0.22 0.28 0.47 0.77 1.06 1.21 1.16 1.14 1.15 1.14 1.11 1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.20 1.24 1.22 1.17 1.06 0.76 0.44 0.23 0.11 0.05 0.02 0.01 0.01 0.00 0.00 0.00 1.39 1.34 0.94 0.59 0.36 0.30 0.36 0.58 0.96 1.32 1.47 1.38 1.18 1.17 1.15 1.12 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.12 1.13 1.15 1.17 1.19 1.37 1.47 1.34 0.96 0.59 0.36 0.28 0.35 0.59 0.96 1.33 1.38 1.33 1.27 1.22 1.17 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.13 1.16 1.20 1.25 1.31 1.44 1.31 0.95 0.59 0.35 0.28 0.36 0.59 0.94 1.37 1.39 1.29 1.20 1.18 1.16 1.12 1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.21 1.25 1.28 1.32 1.28 0.95 0.550 .29 0.14 0.06 0.03 0.01 0.01 0.00 0.00 0.00 1.27 1.19 0.87 0.57 0.35 0.30 0.35 0.55 0.87 1.14 1.33 1.33 1.22 1.19 1.17 1.14 1.11 1.08 1.07 1.06 1.06 1.07 1.08 1.12 1.15 1.17 1.19 1.21 1.28 1.31 1.17 0.87 0.56 0.35 0.28 0.35 0.55 0.87 1.15 1.29 1.29 1.29 1.24 1.19 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.13 1.18 1.22 1.25 1.28 1.30 1.17 0.86 0.56 0.34 0.28 0.35 0.54 0.86 1.18 1.30 1.31 1.23 1.20 1.18 1.14 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.22 1.26 1.25 1.23 1.14 0.85 0.520 .28 0.14 0.07 0.03 0.01 0.01 0.00 0.00 0.00 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 -20 -15 -10 -5 0 3ft24ft29 ft29ft View IES files Sure-Lites Page 38 of 46 SELDWA Emergency Light TD505137EN page 3 June 23, 2020 8:25 AM 53 ft 0.6 0.4 3 ft 0.10.20.20.30.50.71.01.31.62.02.22.22.32.53.76.39.09.48.17.06.66.36.26.16.26.36.67.08.19.49.16.33.72.52.32.32.22.01.61.31.00.70.50.40.30.20.10.10.10.10.10.10.10.10.20.30.40.50.71.01.31.62.02.22.22.32.53.76.39.09.48.17.06.66.36.26.06.26.36.67.08.19.49.06.33.72.52.22.22.22.01.61.31.00.70.50.30.20.20.1 0.10.10.20.30.40.60.81.11.41.71.91.91.92.02.74.66.56.45.55.35.04.74.84.64.84.75.05.35.56.46.54.62.72.01.91.91.91.71.41.10.80.60.40.30.20.20.10.10.10.10.10.10.10.10.20.20.30.40.60.81.11.41.71.91.91.92.02.74.66.46.45.55.35.04.74.84.64.84.75.05.35.56.46.44.62.72.01.91.91.91.71.41.10.80.60.30.20.10.1 0.10.10.10.20.30.40.60.81.01.11.21.21.21.11.21.52.12.21.81.71.82.02.22.32.22.01.81.71.82.22.11.61.21.11.21.21.21.11.00.80.60.50.30.20.20.10.10.10.10.10.10.10.10.10.10.20.20.30.50.60.81.01.11.21.21.21.11.21.52.12.21.81.71.82.02.22.32.22.01.81.71.82.22.11.51.21.11.21.21.21.11.00.80.40.30.20.10.10.1 X Y Z Orient Tilt 23.5 0.5 7.5 90 0 129.5 0.5 7.5 90 0 -29.5 0.5 7.5 90 0 76.5 0.5 7.5 90 0 182.5 0.5 7.5 90 0 X Y Z Orient Tilt 23.5 0.5 7.5 90 0 129.5 0.5 7.5 90 0 -29.5 0.5 7.5 90 0 76.5 0.5 7.5 90 0 182.5 0.5 7.5 90 0 50 ft SELDWA50SD Technical Data AccuLED Optics™ • Precision engineered optics display sharp cutoffs and oval light pattern for a clear path of egress per UL924 standards • Efficient optical design increases spacing distance between units • Provides evenly diffused light pattern throughout the egress path for both 1 footcandle average and 0.1 footcandle minimum • Lens swivel feature provides forward-throw of egress lighting Mechanical Housing • Die-cast aluminum construction • Mounting hole pattern is universal to junction box requirements and suitable for wall mount or conduit mount • Housing color available in bronze, black, white or silver EZ Hang Mounting Feature • Hands-free feature allows installer to hang the emergency light face from the back plate to easily and efficiently make power connections Brownout Circuit • Monitors the flow of AC current • Activates the emergency lighting system when a predetermined reduction/dip of AC power occurs (a dip in voltage will cause most ballasted products to extinguish, causing loss of normal lighting even though a total power failure has not occurred) Low Voltage Disconnect • Low-voltage circuitry disconnects the lighting load when battery’s terminal voltage falls • Disconnect remains in effect until normal utility power is restored, preventing deep battery discharge Self-Diagnostics • Automatically performs all tests required by UL924 and NFPA 101 • Indicates the status of the emergency light at all times using the LED indicator • 90-minute battery power (emergency mode) simulation test occurs randomly once every 12 months • 30-second battery power simulation test occurs every 30 days • Solid-State microprocessor-based system has the ability to accurately detect and warn of system failures • Incorporates all of the standard electronic features • Systematically calibrates itself in the field, reducing installation labor and eliminating manual calibration errors Battery • Rechargeable battery offers high discharge rates and stable performance over a wide range of temperatures • Resealable vent automatically controls cell pressure, assuring safety and reliability • Best suited for harsh ambient temperatures due to the electrolyte is not active in the electrochemical process • Mullion-mount option enabled with the SELDWAMMKIT accessory Warranty • Five-year warranty against defects in material and workmanship • Lead cadmium battery has a seven-year prorated warranty Photometry Sure-Lites Page 39 of 46 SELDWA Emergency Light Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com © 2020 Cooper Lighting Solutions All Rights Reserved. Specifications and dimensions subject to change without notice. TD505137EN page 4 June 23, 2020 8:25 AM Self Diagnostic Self Diagnostic Testing Operations The Sure-Lites Self-Diagnostics is continuously monitoring your emergency fixture, and will signal any failure through the 3 color indicator LED. Initial Operation: When the unit is first powered up, it will go into a 24 hour fast charge, indicated by the indicator LED pulsing green. Once the unit has fully charged, it will perform a self calibration, after which the LED will change to steady green, indicating the unit is fully charged and float charging the battery to maintain readiness. Automatic Testing: The unit will perform a battery capacity, lamp/LED, and charge circuit test every 30 days for 30 seconds. During this time, the indicator LED will change to a steady yellow. It will perform a full battery capacity (90 minute) test once per year. During this time, the indicator LED will change to a blinking yellow. Manual Testing: • 10 Second “Installation ” test – Press and release the test button once during fast charge (blinking green) to initiate a 10 second quick test. The sign will switch to emergency mode for 10 seconds allowing the installer to verify proper installation of the unit, and the LED indicator will turn solid yellow • 30 Second Test - Press and release the test button once during float charge (steady green). The indicator LED will turn steady yellow to indicate the unit is performing a 30 second test of the batteries and lamps/LEDs • 90 Minute Test - Press and release the test button a second time during a 30 second test (steady yellow) to change to a 90 minute test. During this test, the LED indicator will change to blinking yellow, and the circuit will perform a full battery capacity, charge circuit, and LED test • Canceling Test – Press and release the test button during the 90 minute test (flashing yellow) to return the fixture to its original state (fast charge or float charge) Laser Test: The SD versions are equipped with a Laser Test function, that allows the unit to be manually tested without the need to physically press the test button. Shining a laser pointer in the hole marked “LASER TEST” on the bottom of the unit has the same effect as a press and release of the test button. Clearing Failure Codes: • A batter y failure (LED two blink red) can be cleared by replacing the battery. Disconnecting the battery and AC power, or performing a full 90 minute discharge, will reset the error code, however, it will return if the battery is faulty • Char ge Circuit (LED three blink red) and lamp/LED failure (LED four blink red) will clear when the unit successfully passes a manual or automatic 30 second test Indicators: • LED Off - No power t o unit, emergency mode. • LED Steady Gr een - Unit is fully charged and is float charging the battery to maintain readiness. • LED Gr een Pulse - Unit is in a 24 hour fast charge of the battery. • LED Two Blink Red - Battery has failed a capacity test, or the battery is disconnected. See “Clearing Failure Codes” above. • LED Three Blink Red - Battery charge circuit has failed. See “Clearing Failure Codes” above. • LED F our Blink Red - Lamps have burned out, or on an EXIT/Combo, 50% or more of the LEDs have failed. See “Clearing Failure Codes” above. • LED Steady Y ellow - 30 second test or 10 second quick test (Fast Charge only). • LED Blinking Y ellow - 90 minute test. Maintenance: None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local codes. OFF - EMERGENCY MODE / POWER OFF 2 BLINK RED - BATTERY FAILURE STEADY GREEN - FULL / FLOAT CHARGE STEADY BLINK YELLOW - 90 MINUTE TEST 3 BLINK RED - CHARGE CIRCUIT FAILURE 4 BLINK RED - LAMP/ LED FAILURE STEADY YELLOW - QUICK TEST STEADY BLINK GREEN - FAST CHARGE SURE-LITES SELF DIAGNOSTICS Sure-Lites Page 40 of 46 Specifications and dimensions subject to change without notice. Cooper Lighting Solutions 1121 Highway 7 4 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com LUMEN MAINTENANCE POWER AND LUMENS BY FIXTURE MODEL CURRENT DRAW XTOR CROSSTOUR LED 100 01 02 03 04 05 06 07 08 09 01 00 75 80 85 90 95 Hours (Thousands) Lumen Maintenance (Percent) 50°C 40°C 25°C TD514013EN December 14, 2021 5:27 PM page 2 Voltage Model Series XTOR1B XTOR2B XTOR3B XTOR4B 120V 0.103A 0.15A 0.22A 0.34A 208V 0.060A 0.09A 0.13A 0.17A 240V 0.053A 0.08A 0.11A 0.17A 277V 0.048A 0.07A 0.10A 0.15A 347V 0.039A 0.06A 0.082A 0.12A Ambient Temperature TM-21 Lumen Maintenance (72,000 Hours) Theoretical L70 (Hours) XTOR1B Model 25°C > 90% 255,000 40°C > 89% 234,000 50°C > 88% 215,000 XTOR2B Model 25°C > 89% 240,000 40°C > 88% 212,000 50°C > 87% 196,000 XTOR3B Model 25°C > 89% 240,000 40°C > 88% 212,000 50°C > 87% 196,000 XTOR4B Model 25°C > 89% 222,000 40°C > 87% 198,000 50°C > 87% 184,000 LED Information XTOR1B XTOR1B-W XTOR1B-Y XTOR2B XTOR2B-W XTOR2B-Y XTOR3B XTOR3B-W XTOR3B-Y XTOR4B XTOR4B-W XTOR4B-Y Delivered Lumens (Wall Mount) 1,418 1,396 1,327 2,135 2,103 1,997 2,751 2,710 2,575 4,269 4,205 3,995 Delivered Lumens (With Flood Accessory Kit) 1 1,005 990 940 1,495 1,472 1,399 2,099 2,068 1,965 3,168 3,121 2,965 B.U.G. Rating 2 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G0 B2-U0-G0 B2-U0-G0 CCT (Kelvin) 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 CRI (Color Rendering Index) 70 70 70 70 70 70 70 70 70 70 70 70 Power Consumption (Watts) 12W 12W 12W 18W 18W 18W 26W 26W 26W 38W 38W 38W NOTES: 1 Includes shield and visor. 2 B.U.G. Rating does not apply to floodlighting. Page 41 of 46 Specifications and dimensions subject to change without notice. Cooper Lighting Solutions 1121 Highway 7 4 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com XTOR CROSSTOUR LED STOCK ORDERING INFORMATION ORDERING INFORMATION TD514013EN December 14, 2021 5:27 PM page 3 Sample Number : XTOR2B-W-WT-PC1 Series 1 LED Kelvin Color Housing Color Options (Add as Suffix) Accessories (Order Separately) 8 XTOR1B=Small Door, 12W XTOR2B =Small Door, 18W XTOR3B =Small Door, 26W XTOR4B =Medium Door, 38W BAA-XTOR1B=Small Door, 12W, Buy American Act Compliant 7 TAA-XTOR1B =Small Door, 12W Trade Agreements Act Compliant 7 BAA-XTOR2B =Small Door, 18W, Buy American Act Compliant 7 TAA-XTOR2B =Small Door, 18W, Trade Agreements Act Compliant 7 BAA-XTOR3B =Small Door, 26W, Buy American Act Compliant 7 TAA-XTOR3B =Small Door, 26W, Trade Agreements Act Compliant 7 BAA-XTOR4B = Medium Door, 38W, Buy American Act Compliant 7 TAA-XTOR4B = Medium Door, 38W, Trade Agreements Act Compliant 7 [Blank] = Bright White (Standard), 5000K W=Neutral White, 4000K Y=Warm White, 3000K [Blank] = Carbon Bronze (Standard) WT=Summit White BK=Black BZ=Bronze AP=Grey GM=Graphite Metallic DP=Dark Platinum PC1=Photocontrol 120V 2 PC2=Photocontrol 208-277V 2, 3 347V=347V 4 HA=50ºC High Ambient 4 WG/XTOR =Wire Guard 5 XTORFLD-KNC =Knuckle Floodlight Kit 6 XTORFLD-TRN =Trunnion Floodlight Kit 6 XTORFLD-KNC-WT =Knuckle Floodlight Kit, Summit White 6 XTORFLD-TRN-WT =Trunnion Floodlight Kit, Summit White 6 EWP/XTOR = Escutcheon Wall Plate, Carbon Bronze EWP/XTOR-WT = Escutcheon Wall Plate, Summit White NOTES: 1. DesignLights Consortium ® Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. 2. Photocontrols are factory installed. 3. Order PC2 for 347V models. 4. Thru-branch wiring not available with HA option or with 347V. XTOR3B not available with HA and 347V or 120V combination. 5. Wire guard for wall/surface mount. Not for use with floodlight kit accessory. 6. Floodlight kit accessory supplied with knuckle (KNC) or trunnion (TRN) base, small and large top visors and small and large impact shields. 7. Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements. 8. Accessories sold separately will be separately analyzed under domestic preference requirements. Consult factory for further information. Domestic Preferences 1 12W Series 18W Series 26W Series 38W Series [Blank]=Standard XTOR1B=12W, 5000K, Carbon Bronze XTOR2B =18W, 5000K, Carbon Bronze XTOR3B =26W, 5000K, Carbon Bronze XTOR4B =38W, 5000K, Carbon Bronze BAA=Buy American Act XTOR1B-WT =12W, 5000K, Summit White XTOR2B-W =18W, 4000K, Car- bon Bronze XTOR3B-W =26W, 4000K, Carbon Bronze XTOR4B-W =38W, 4000K, Carbon Bronze TAA= Trade Agreements Act XTOR1B-PC1 =12W, 5000K, 120V PC, Carbon Bronze XTOR2B-WT =18W, 5000K, Sum - mit White XTOR3B-WT =26W, 5000K, Summit White XTOR4B-WT =38W, 5000K, Summit White XTOR1B-W =12W, 4000K, Carbon Bronze XTOR2B-PC1 = 18W, 5000K, 120V PC, Carbon Bronze XTOR3B-PC1 = 26W, 5000K, 120V PC, Carbon Bronze XTOR4B-PC1 = 38W, 5000K, 120V PC, Carbon Bronze XTOR2B-W-PC1 = 18W, 4000K, 120V PC, Car- bon Bronze XTOR3B-W-PC1 =26W, 4000K, 120V PC,Carbon Bronze XTOR4B-W-PC1 = 38W, 4000K, 120V PC, Carbon Bronze XTOR2B-347V = 18W, 5000K, Carbon Bronze, 347V XTOR3B-347V =26W, 5000K, Carbon Bronze, 347V XTOR4B-347V =38W, 5000K, Carbon Bronze, 347V XTOR2B-WT-PC1 =18W, 5000K, 120V PC,Summit White XTOR3B-PC2 =26W, 5000K, 208-277V PC, Carbon Bronze NOTES: 1. Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements. Page 42 of 46 Page 43 of 46 1 DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB)) aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall.. PROJECT NAME: 150 William Hilton Parkway DRB-000605-2025 Old Schoolhouse Park toilet Facility DATE: 7/08/2025 CATEGORY: Conceptual RECOMMENDATION: Approval Approval with Conditions Denial APPLICATION MATERIAL DRB REQUIREMENTS Complies Yes No Not Applicable Comments or Conditions Demolition Plan if needed Existing Conditions match As-Built Dimensioned Details and of Sections Detail Illustrating Connection to Existing Structure New Building Details Match Existing Building Details ARCHITECTURAL DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Structure is designed to be appropriate to the neighborhood Promotes pedestrian scale and circulation Design is unobtrusive and set into the natural environment Utilizes natural materials and colors Avoids distinctive vernacular styles Design is appropriate for its use All facades shall have equal design characteristics Page 44 of 46 2 Avoids monotonous planes or unrelieved repetition Has a strong roof form with enough variety to provide visual interest Overhangs are sufficient for the façade height. Forms and details are sufficient to reduce the mass of the structure Human scale is achieved by the use of proper proportions and architectural elements Utilizes a variety of materials, textures and colors Incorporates wood or wood simulating materials Windows are in proportion to the facade Details are clean, simple and appropriate while avoiding excessive ornamentation Utilities and equipment are concealed from view Decorative lighting is limited and low wattage and adds to the visual character Lighting specs and details are provided in this submittal. Accessory elements are designed to coordinate with the primary structure LANDSCAPE DESIGN DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions Treats the Landscape as a major element of the project Please provide landscaping around the toilet facility. Provides Landscaping of a scope and size that is in proportion to the scale of the development Provide landscaping that is scaled and proportioned to the building. Landscape is designed so that it may be maintained in its natural shape and size Preserves a variety of existing native trees and shrubs Provides for a harmonious setting for the site’s structures, parking areas or other construction Location of existing trees and new trees provides street buffers, mitigation for parking lots, and an architectural complement that visually mitigates between parking lots and building(s) Shrubs are selected to complement the natural setting, provide visual interest and screen less-desirable elements of the project A variety of species is selected for texture and color Provide a variety of species for enhanced texture and color. Provides overall order and continuity of the Provide a Planting Plan. Page 45 of 46 3 Landscape plan Native plants or plants that have historically been prevalent on the Island are utilized Please utilize native plant life. A variety of sizes is selected to create a “layered” appearance for visual interest and a sense of depth Provide a layered appearance as much as possible for visual interest. The location of existing mature trees is taken into account in placement of shrubs so as not to damage tree roots Proper spacing and location for plants to reach their mature size and natural shape while avoiding excessive or unnatural pruning Proposed groundcovers are evergreen species with low maintenance needs Large, grassed lawn areas encompassing a major portion of the site are avoided The adjacent development is taken into account in determining the most appropriate buffer so as not to depart too dramatically from the neighborhood Ornamentals and Annuals are limited to entrances and other focal points NATURAL RESOURCE PROTECTION DESIGN GUIDE/LMO CRITERIA Complies Yes No Not Applicable Comments or Conditions An effort has been made to preserve existing trees and under story plants Supplemental and replacement trees meet LMO requirements for size, species and number Wetlands if present are avoided and the required buffers are maintained Sand dunes if present are not disturbed COMMENTS & CONDITIONS Staff recommends approval of the Sign System submittal with the following conditions: 1. Provide a materials board with the color samples. 2. Provide a Planting Plan for the landscape around the toilet facility. 3. Any additional information as required by the Board. Page 46 of 46

Source: Town of Hilton Head Island website. First collected Nov 3, 2026.