Design Review Board Meeting — Agenda Packet
Town of Hilton Head Island · Beaufort County · Design Review Board · meeting of Jul 8, 2025 · Agenda packets
Open the original document More from Town of Hilton Head Island
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Town of Hilton Head Island
Design Review Board Meeting
Tuesday, July 8, 2025, 2:30 PM
1 Town Center Court, Hilton Head Island, SC
Benjamin M. Racusin Council Chambers
The Design Review Board meeting will be held in person at Town Hall in the
Benjamin M. Racusin Council Chambers.
1. Call to Order
2. Adoption of the Agenda
3. Approval of the Minutes
a. Regular Meeting Minutes of June 24, 2025
4. Unfinished Business
5. New Business
a. DRB-000605-2025 - Hilton Head Island Old Schoolhouse Park Toilet Facility -
Conceptual
6. Public Comment - Non Agenda Items
7. Board Business
8. Staff Reports
9. Adjournment
FOIA Compliance: Public notification of this meeting has been published, posted, and
distributed in compliance with the South Carolina Freedom of Information Act and the
requirements of the Town of Hilton Head Island.
In accordance with the requirements of Title II of the Americans with Disabilities Act of
1990 ("ADA"), the Town of Hilton Head Island will not discriminate against qualified
individuals with disabilities on the basis of disability in its services, programs, or
activities. Auditory accommodations are available. Any person requiring further
accommodation should contact the Town of Hilton Head Island ADA Coordinator as
soon as possible but no later than 48 hours before the scheduled event.
Page 1 of 46
Municipal Association of South Carolina (MASC) Civility Pledge:
“I pledge to build a stronger and more prosperous community by advocating for civil
engagement, respecting others and their viewpoints, and finding solutions for the
betterment of my city or town.”
Page 2 of 46
Town of Hilton Head Island Design Review Board
Meeting Minutes
6/24/2025 Page | 1
Town of Hilton Head Island
DESIGN REVIEW BOARD MEETING
Tuesday, June 24, 2025, 2:30 PM
Minutes
1. Call to Order
The meeting was called to order at 2:30pm.
2. Adoption of the Agenda
Mr. Parker made a motion to approve the agenda. Ms. Fitzpatirck seconded the motion, which
passed unanimously.
3. Approval of the Minutes
a. Regular Meeting Minutes of June 10, 2025
Mr. Parker made a motion to approve the meeting minutes of June 10th. Ms. Pastor
seconded the motion, which passed unanimously.
4. Unfinished Business
a. DRB-000348-2025 - 862 William Hilton Parkway - Beach Properties - Sign System
Melissa Pual-Leto, Principle Planner, presented the Beach Properties Sign System. The
applicant answered questions from the Board.
Ms. Pastor made a motion to approve with the following conditions: study the scale of the
gooseneck lighting and submit to Staff for review; move the street address numbers on
the monument sign up higher or ensure that they're not obscured by landscaping; submit
a landscape plan to Staff for approval. Mr. Parker seconded, which passed unanimously.
5. New Business
a. DRB-000574-2025 - 70 Wilborn Road - Hilton Head Island High School - Alteration
Ms. Paul-Leto presented the Hilton Head Island High School conceptual review for Phase
2 to the Board. The applicant answered questions from the Board.
Mr Parker made a motion to approved with the following conditions: adhere to all Staff
comments; incorporate design cues from phase 1 so that they speak to each other a bit
more; introduce plant beds to the large paved area in front of the multipurpose room; all
windows and overhead doors should be dark bronze; all lighting and materials to match
phase 1; lighting to be coordinated among all the plans, especially the landscaping and
civil plans; extend the parking access wherever we have a pedestrian aisle down the
middle of the parking lots; look at extending those pathways for overflow parking when
Page 3 of 46
Town of Hilton Head Island Design Review Board
Meeting Minutes
6/24/2025 Page | 2
people come to large sports events; think through the circulation access from all parking
lots for large events or games; provide service yard detailing and locations; the outdoor
classroom screen detailing to be submitted in the next package for review and the top line
be more organic to go along with the fence detailing; introduce two shades of blue to
make it more similar to phase 1. Mr. Theodore seconded the motion, which passed
unanimously.
b. DRB-000580-2025 - 93 Matthews Drive - Food Lion - Conceptual
Vice Chair Lippert recused herself, passed the gavel to Mr. Parker, and left the room. Ms.
Paul-Leto presented Food Lion for conceptual review. The applicant answered numerous
questions from the Board. After further review, the Board suggested tabling the
application, and the applicant withdrew the application until a later date.
6. Public Comment - Non Agenda Items
7. Staff Reports
8. Board Business
Vice Chair Lippert returned to the dias. The Board discussed observed potential design code
violations and design concerns around the island.
9. Adjournment
The meeting adjourned at 5:07.
The recording of this Meeting can be found on the Town’s website
at www.hiltonheadislandsc.gov
Page 4 of 46
Page 5 of 46
Last Revised 01/21/15 1
Applicant/Agent Name: ______________________________ Company: _____________________________________
Mailing Address: ___________________________________ City: _________________ State: ______ Zip: ________
Telephone: ___________________ Fax: _________________ E-mail: _______________________________________
Project Name: _________________________________ Project Address: _____________________________________
Parcel Number [PIN]: R__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
Zoning District: _______________________________ Overlay District(s): ___________________________________
Town of Hilton Head Island
Community Development Department
One Town Center Court
Hilton Head Island, SC 29928
Phone: 843-341-4757 Fax: 843-842-8908
www.hiltonheadislandsc.gov
CORRIDOR REVIEW, MAJOR
DESIGN REVIEW BOARD (DRB) SUBMITTAL REQUIREMENTS
Digital Submissions may be accepted via e-mail by calling 843-341-4757.
Project Category:
_____ Concept Approval – Proposed Development _____ Alteration/Addition
_____ Final Approval – Proposed Development _____ Sign
FOR OFFICIAL USE ONLY
Date Received: _____________
Accepted by: ______________
DRB #:___________________
Meeting Date: _____________
Submittal Requirements for All projects:
_____ Private Architectural Review Board (ARB) Notice of Action (if applicable): When a project is within the
jurisdiction of an ARB, the applicant shall submit such ARB’s written notice of action per LMO Section 16-
2-103.I.4.b.iii.01. Submitting an application to the ARB to meet this requirement is the responsibility of the
applicant.
_____ Filing Fee: Concept Approval-Proposed Development $175, Final Approval – Proposed Development $175,
Alterations/Additions $100, Signs $25;
cash or check made payable to the Town of Hilton Head Island.
Additional Submittal Requirements:
Concept Approval – Proposed Development
_____ A survey (1"=30' minimum scale) of property lines, existing topography and the location of trees meeting the
tree protection regulations of Sec. 16-6-104.C.2, and if applicable, location of bordering streets, marshes and
beaches.
_____ A site analysis study to include specimen trees, access, significant topography, wetlands, buffers, setbacks,
views, orientation and other site features that may influence design.
_____ A draft written narrative describing the design intent of the project, its goals and objectives and how it
reflects the site analysis results.
_____ Context photographs of neighboring uses and architectural styles.
_____ Conceptual site plan (to scale) showing proposed location of new structures, parking areas and landscaping.
_____ Conceptual sketches of primary exterior elevations showing architectural character of the proposed
development, materials, colors, shadow lines and landscaping.
Dale N. Strecker
Hord Coplan Macht
P.O. Box 5910
Hilton Head Island
SC
29938
843-785-2199
dstrecker@hcm2.com
Old Schoolhouse Park Toilet Facility
150 & 152 William Hilton Parkway
R 511 007 000 0247 0000 (#150) & R 511 007 000 0070 0000 (#152)
COR
PR
N/A
** Filing fee to be paid by the Town of Hilton Head Island
**
Page 6 of 46
Page 7 of 46
ARCHITECTURE
LANDSCAPE ARCHITECTURE
INTERIOR DESIGN
PLANNING
10 Palmetto Business Park Rd
Suite 201
Hilton Head Island, SC 29928
P 843.785.2199
www.hcm2.com
June 18, 2025
Community Development Staff
Town of Hilton Head Island
One Town Center Court
Hilton Head Island, SC 29928
Subject: Old Schoolhouse Park Toilet Facility – Major Desig n Review Board Submittal
Project Narrative
Need for the Project:
The Town’s Old Schoolhouse Park located at 152 William Hilton Parkway currently
provides open field space, a basketball court, six pickleball courts, and a gravel parking
area serving the park. The park currently has no toilet or handwashing facilities and is
served by a single portable toilet. There is currently no covered area to protect park
users from the elements. This project is for a new building to be located adjacent to the
existing pickleball court that would include a toilet room with running water, a covered
porch for protection of users from the elements, a drinking fountain, and a storage room
for use by the Town.
Scope of Work:
All existing elements on the site will remain largely as-is. The open field space,
basketball court and pickleball courts will remain. The gravel parking area will be
modified to incorporate a paved handicapped parking space and a concrete sidewalk will
be added connecting the handicapped parking space to the existing sidewalk encircling
the pickleball courts. The new toilet building will directly abut the existing concrete
sidewalk at the pickleball courts in what is currently grassy area. No existing trees will be
removed or impacted as part of the work. New landscaping would be provided adjacent
to the new building.
Site Analysis:
The site is in the Parks & Recreation (PR) Zoning District. The area where the toilet
building is proposed to be located is currently level, open, grassy space located on high
ground and away from any wetlands. There are no trees within or near the area of
proposed work. The building is proposed to be sited in an area well away from required
setback and buffer areas. The building will be placed adjacent to the pickleball courts,
approximately 250’ from the edge of the sidewalk at William Hilton Parkway. Due to the
building’s proposed location, it will be minimally visible from the road and no buffers or
setbacks will be impacted or modified.
Page 8 of 46
Page 2 of 2
Building Design:
The new building will be 17’-4” wide by 24’-2” long and will encompass approximately 174
square feet of enclosed area, with the balance of building area being covered porch. The
building has been designed to be nearly identical to a similar facility at the Town’s
Cordillo Tennis Courts facility on Cordillo Parkway. That structure, however, is located
below flood elevation and thus has removable flood barriers at the doorway openings.
This building will be located above flood elevation and has been simplified to omit the
removable flood barriers. All building materials, finishes, and colors will match those at
the Cordillo Tennis Courts facility. The selection of similar materials, colors, and other
elements will allow the Town to maintain consistency of their park facilities across the
Island.
Kind regards,
Hord Coplan Macht
Dale N. Strecker, AIA
Project Manager
cc: Neal Eike, Town of Hilton Head Island
Page 9 of 46
Page 10 of 46
Untitled Map
Write a description for your map.
Legend
152 William Hilton Pkwy
1000 ft
N➤➤
N
Property Line
Proposed Structure
Town sidewalk / pathway
along edge of property,
directly abutting William
Hilton Parkway
Spanish Wells Road
Wild Horse
Road
Old Schoolhouse Park Site - Town Vicinity Map
Existing Pickleball Courts
Existing Basketball Court
Page 11 of 46
Exhibit 4A
Consolidation Plat joining 150 & 152
William Hilton Parkway into one property.
Page 12 of 46
Exhibit 4B
Survey of property without proposed improvements.
Page 13 of 46
New Town of Hilton Head Island
Old Schoolhouse Park Toilet Facility
150 & 152 William Hilton Parkway
Design Review Board (DRB) Context Photographs
View of site from William Hilton Parkway. Building will be approximately 100’ beyond white car.
View of adjacent property to the west.
Page 14 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 2 of 7
View of adjacent property to the west.
View of property on opposite side of William Hilton Parkway.
Page 15 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 3 of 7
View of property on opposite side of William Hilton Parkway.
View of property on opposite side of William Hilton Parkway.
Page 16 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 4 of 7
View of home at east side of Old Schoolhouse Park.
View of Old Schoolhouse Park and proposed site from entry into parking lot.
Building Site
Page 17 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 5 of 7
View of Old Schoolhouse Park and proposed site from the east. Pickleball courts on the left.
View of proposed building site between pickleball courts and existing wooded area.
Building Site
Building Site
Page 18 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 6 of 7
View of proposed building site between pickleball courts and existing wooded area.
View of proposed building site between pickleball courts and existing wooded area.
Building Site
Building Site
Page 19 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Context Photographs
Page 7 of 7
View of proposed building site between pickleball courts and existing wooded area.
Building Site
Page 20 of 46
ABBREVIATIONS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
R
S
T
V
W
Q
G
T
A.C.
A.D.
A.H.U.
A.T.C.
A.T.
ARCH.
APPROX.
A.O.
AMP., A.
ALUM.
ALT.
A.F.F.
B.T.U.
BRK
BRG.
BOT.
BM.
BLK.
BLDG.
BD.
BAL.
CAB.
CAP.
C/B
C.D.
CEM.
CER.
C.F.C.I.
C.F.M.
CIRC.
C.J.
CK'D
CIR
L, CL.
CEIL.
CL.
C.O.
COL.
CONC.
COND.
CONN.
CONST.
CONT.
CONTR. JT.
C.T.
C. TO C.
C
DET.
DIA.
DIFF.
DIM.
DISC.
D.J.
DN.
DR.
D.S.
DWG.(S)
EA.
E.C.
E.F.
EL.
ELEC.
EQUIP.
E.W.C.
EXH.
EXT.
EXIST.
F.A.
F.C.
F.D.
F.E.C.
FIN.
FL.
FT.
FTG.
FFE
F.E.
GA.
GAL.
GALV.
GL.
GND.
GOV'T
GPH
GPM
GR.
GWB
GYP.
H.
H.B.
H.C.
HT.
HM
H.P.
HR.
HTG.
HTR.
H.&V.
HW.
HYD.
I.D.
I.E.
IN.
INCAND.
INSUL.
INT.
J.B.
JCT.
JT.
KVA
KW
LB.,#
LG.
L.P.
LTG.
M.
MAINT.
MAX.
M.D.P.
MECH.
MTL.
MIN.
MISC.
M.O.
MTD.
MTG.
M.V.
M.G.T.
N.A.
N.I.C.
NO.
O.A.
O.C.
O.D.
OH.
OPNG.
OPP.
O.S.B.
PART.
PER.
L, PL.
PLBG.
PLYW'D
PNL.
PRESS.
PSF
PSI
P.T.
PTD.
QTR.
QUAN.
R.
R.A.
RAD.
RD.
REC'D.
RECIRC.
RECP.
REINF.
REQ.
RET.
R.G.
RM.
R.P.M.
T.
TEL.
TEMP.
THK.
THD.
TOIL.
TYP.
VCT
VENT.
VERT.
VTR
W/
WD.
WF
W.G.
WP.
S.A.
SCH.
SECT.
SERV.
SHT.
S.J.
SQ. FT.
ST.
STOR.
STRUCT.
SUSP.
SW.
S.
SIM.
P
O.H.
MAT.
PR.
SPEC.
SLR.
STN.
O.S.D.
O.F.E.
O.F.C.I.
O.F.O.I.
OWNER FURNISHED/
E.I.F.S.
STL.
MFR.
E.J.
M.B. T.B.
S.S. STAINLESS STEEL
BR
CG
C.M.U.
AIR CONDITIONED
AREA DRAIN
AIR HANDLING UN
ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUM
AMPERES
ACCESS OPENING
APPROXIMATELY
ARCHITECTURAL
ASPHALT TILE
ACOUSTIC TILE CEILING
BALANCE
BOARD
BUILDING
BLANK
BEAM
BOTTOM
BUMPER RAIL
BEARING
BRICK
BRITISH THERMAL UNIT
CABINET
CAPACITY
CIRCUIT BREAKER
CEILING DIFFUSER
CEMENT
CERAMIC
CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CUBIC FEET/MINUTE
CORNER GUARD
CIRCULATING
CONTROL JOINT
CHECKERED
CIRCUIT
CENTER LINE
CEILING
CLOSET
CONCRETE MASONRY
UNIT
CLEAN OUT
COLUMN
CONCRETE
CONDENSATE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTION JOINT
CERAMIC TILE
CENTER TO CENTER
DETAIL
DIAMETER
DIFFUSER
DIMENSION
DISCONNECT
DUMMY JOINT
DOWN
DRAIN
DOWN SPOUT
DRAWING(S)
EACH
EMPTY CONDUIT
EXHAUST FAN
EXTERIOR INSULATION
AND FINISHING SYSTEM
ELEVATION
ELECTRIC
EQUIPMENT
ELECTRIC WATER COOLER
EXHAUST
EXPANSION JOINT
EXTERIOR
EXISTING
FIRE ALARM
FLEXIBLE CONNECTION
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER
CABINET
FINISH
FLOOR
FOOT, FEET
FOOTING
ELEVATION
FINISHED FLOOR
GAGE
GALLON
GALVANIZED
GLASS
GROUND
GOVERNMENT
GALLONS/HOUR
GRILLE
GALLONS/MINUTE
GYPSUM WALL BOARD
GYPSUM
HIGH
HOSE BIBB
HOLLOW CORE
HEIGHT
HOLLOW METAL
HORSE POWER
HOUR
HEATING
HEATER
HARDWARE
HYDRANT
INSIDE DIAMETER
INVERT ELEVATION
INCHES
INCANDESCENT
INSULATION
INTERIOR
W.W.F. WELDED WIRE FABRIC
WEATHERPROOF
WATER GAGE
WIDE FLANGE
WOOD
WITH
VENT THRU ROOF
VERTICAL
VENTILATION
NYL COMPOSITE TILE
TYPICAL
TOILET
THRESHOLD
THICKNESS
TEMPERATURE
TELEPHONE
TACK BOARD
TOILET
SWITCH
SUSPENDED
STRUCTURAL
STONE
STORAGE
STEEL
STAINED
SQUARE FEET
SEALER
SPECIFICATIONS
SLIP JOINT
SIMILAR
SHEET
SERVICE
SECTION
SCHEDULE
SUPPLY AIR
SUPPLY
REVOLUTIONS/MINUTE
ROOM
RETURN GRILLE
RETURN
REQUIRED
REINFORCING
RECEPTACLE
RECIRCULATING
RECESSED
ROOF DRAIN
RADIUS
RETURN AIR
RISER
QUANTITY
QUARTER
PAINTED
PRESSURE TREATED
POUNDS/SQUARE INCH
POUNDS/SQUARE FOOT
PRESSURE
PAIR
PANEL
PLYWOOD
PLUMBING
PLATE
PERIMETER
PARTITION
OPEN SIGHT DRAIN
ORIENTED STRANDBOARD
OPPOSITE
OPENING
OVERHEAD
OPPOSITE HAND
OWNER INSTALLED
OWNER FURNISHED/
CONTRACTOR INSTALLED
OUTSIDE DIAMETER
ON CENTER
OUTDOOR AIR
NUMBER
NOT IN CONTRACT
NOT APPLICABLE
MATT GLAZE TILE
MECHANICAL VENTILATION
MOUNTING
MOUNTED
MASONRY OPENING
MISCELLANEOUS
MINIMUM
METAL
MANUFACTURER
MECHANICAL
MAIN DISTRIBUTION PANEL
MARKER BOARD
MAXIMUM
MATERIAL
MAINTENANCE
MOTOR
LIGHTING
LIGHTING PANEL
LONG
POUND
KILOWATT
KILOVOLT AMPERE
JOINT
JUNCTION
JUNCTION BOX
VENTILATING
HEATING AND
EQUIPMENT
OWNER FURNISHED
U.N.O UNLESS NOTED OTHERWISE
MATERIALS LEGEND
BRICK (SEE PLANS AND DETAILS
FOR ALTERNATE CONFIGURATIONS)
CONCRETE
GROUT, MORTAR, SAND
EARTH
COMPACTED SOIL
CMU (SEE PLANS AND DETAILS
FOR ALTERNATE CONFIGURATIONS
ROUGH LUMBER (DISCONTINUOUS
ROUGH LUMBER (CONTINUOUS)
BLOCKING)
FINISH WOOD
ALUMINUM
FERROUS METALS - STEEL
POROUS FILL
GLAZING
GYPSUM WALLBOARD
(LARGE SCALE)
PLYWOOD
RIGID INSULATION
ACOUSTIC TILE
CARPET
BATT INSULATION
PROJECT TEAM
NAME OF PROJECT: TOWN OF HILTON HEAD ISLAND - OLD SCHOOLHOUSE PARK TOILET FACILITY
ADDRESS: 152 WILLIAM HILTON PARKWAY
HILTON HEAD ISLAND, SOUTH CAROLINA, 29926
DISCIPLINE DESIGNER CONTACT PHONE NUMBER
ARCHITECT HORD COPLAN MACHT BARRY H. TAYLOR, AIA, LEED 843 -785 -2199
STRUCTURAL ENGINEER SHEARLOCK ENGINEERING JAKE EAVENSON, PE 843 -473 -8767
PLUMBING ENGINEER
MECHANICAL ENGINEER
ELECTRICAL ENGINEER CDDC RYAN M. YOCCO, PE 843 -384 -4731
OWNER CONTACT: NEAL EIKE, SENIOR PROJECT MANAGER, TOWN OF HILTON HEAD ISLAND
ISLANDS ENGINEERING CARL QUANTE, PE 912 -356 -9036
ISLANDS ENGINEERING CARL QUANTE, PE 912 -356 -9036
CIVIL ENGINEER STURRE ENGINEERING NATHAN STURRE, PE 843 -929 -9432
GENERAL NOTES
1. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED ON DRAWINGS FOR LAYOUT OF WORK.
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LISTED BUILDING CODES AND WITH THE MOST
STRINGENT BEING ENFORCED WHERE A CONFLICT ARISES.
3. THE HOURS AND DAYS OF OPERATION SHALL CONFORM TO OWNER'S REQUIREMENTS. VERIFY WITH
OWNER.
4. THE SCHEDULING OF WORK WHICH PRODUCES EXCESSIVE NOISE OR VIBRATION SHALL BE
SHCEDULED WITH THE OWNER'S REPRESENTATIVE. THE OWNER'S REPRESENTATIVE SHALL
DEFINE THE TERM "EXCESSIVE".
5. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT IN WRITING
IMMEDIATELY UPON DISCOVERY OF CONDITIONS WHICH ARE IN CONFLICT WITH CONTRACT
DOCUMENTS.
ABBREVIATIONS SYMBOLS
?
?
?
?
?
?
?
?
?
? ?
?
?
?
?
ELEVATION INDICATOR
SECTION MARK
DOOR INDICATOR
EXTERIOR ELEVATION MARK
ELEVATION NUMBER
SHEET NUMBER
SHEET NUMBER
SECTION NUMBER
DIRECTION OF VIEW
NAME
ELEVATION
SIM
1
A-101
101
REF
REF
REF
REF
A101
1
1
1
1
MATERIALS LEGEND
Table 5.6-2. BASIC CODE REVIEW INFORMATION
B. Municipality and/or County Where Project is Located:
C. Jurisdiction for:
(Provide the name of the applicable authority)
1. Site Work:
3. Water:
4. Sewer:
1.2. Is Project in a Flood Plain? Yes No
If building is a mixed occupancy per IBC 302.3, indicate the additional occupancy groups present:
3 Type of Construction (per IBC Chapter 6):
(All site information is required if project affects the site or if site information is necessary for
design purposes. All floodplain information is required even if project does not affect site and
is not in flood plain.
1.1 Total Area of Project Site (in acres):
5. Zoning: Land Use Zone:
A. Flood Map Information: Community No.: Panel No.:
B. Flood Zone: Base Flood Elevation (BFE):
1.3. Is Project in Wetlands Area? Yes No
(per IBC Chapter 3)
1 Site Development
2 Occupancy
A. Construction Classification:
B. Is the building construction protected or unprotected
C. Is the building construction of combustible or noncombustible materials
A. Occupancy Classification: Group:
B. Additional Occupancy Classification(s) Group:
2. Fire Department: Project in Fire District? Yes No
Table 5.6-6: Fire Resistance Rating of Building Elements
Building Element
Structural Frame Including
Columns, Girders and Trusses
(per IBC Table 601)
Bearing Walls, Exterior
(per IBC Table 601)
C. Building Lowest Floor Elev.:
A. Total Area of Project Site that will be Disturbed/Developed :
Project Designed in Accordance With:
1. International Building Code, 2021 Edition with SC Modifications
2. International Energy Conservation Code, 2009 Edition
3. International Fire Code, 2021 Edition with SC Modifications
4. International Plumbing Code, 2021 Edition with SC Modifications
5. National Electrical Code, NFPA 70, 2020 Edition with SC Modifications
6. ICC/ANSI-A117.1-2017, Accessible and Usable Buildings and Facilities
7. NFPA 101 Life Safety Code, 2012 Edition
0
0
N/A
0
0
0
0 0
N/A
Hilton Head Island, SC
Hilton Head Island, SC
Hilton Head Island, SC
N/A
0
0
00
N/A
N/A
N/A
N/A
N/A
Utility & Accessory U
N/A
Unprotected
Combustible
0
0
0
N/A
N/A
Type VB
Hilton Head PSD
Less than 1/4 Acre
PR - Parks & Recreation
X
Hilton Head PSD
Rating As
Designed
(in hours)
Rating As
Required
(in hours)
Testing Agency & Design
Number (UL, FM, etc.)
Bearing Walls, Interior
(per IBC Table 601)
Non-bearing Walls & Partitions,
Exterior
(per IBC Table 601)
Non-bearing Walls & Partitions,
Interior
(per IBC Table 601)
Floor Construction, Including
Supporting Beams & Joists
(per IBC Table 601)
Roof Construction, Including
Supporting Beams & Joists
(per IBC Table 601)
Fire Walls
(per IBC Table 705.4)
Fire Barriers
(per IBC Table 706.3.9)
Shaft Enclosures
(per IBC Section 707
Fire Partitions
(per IBC Section 708
Parks & Recreation
X and X-Shaded 11.0'
TBD' MSL
X
BASIC CODE INFORMATION
VICINITY MAP
LIST OF DRAWINGS
GI -100 GENERAL INFORMATION
S300 FOUNDATION DETAILS
PLUMBING
P1.0 PLUMBING WATER/SEWER PLAN, SCHEDULES
FLOOD DESIGN STRUCTURAL CALCULATIONS
STRUCTURAL
MECHANICAL
M1.0 MECHANICAL HVAC PLAN AND SCHEDULES
ELECTRICAL
E-001 ELECTRICAL NOTES AND SCHEDULES
E-100 ELECTRICAL PLANS AND DETAILS
S100 STRUCTURAL NOTES
GI -110 PROJECT NOTES AND SPECIFICATIONS
S200 FOUNDATION PLAN
AE -101 PLANS
AE -301 SECTIONS / DETAILS
ARCHITECTURAL
C-1 TITLE SHEET
AE -601 DOOR SCHEDULE & DETAILS
AI -201 INTERIOR ELEVATION / FINISH SCHEDULE
C-2 GENERAL NOTES & LEGEND
CIVIL
AE -201 BUILDING ELEVATIONS & SECTIONS
E-200 ELECTRICAL SITE PLAN
C-3 EXISTING CONDITIONS
C-4 DEMOLITION & SWPP PLAN
C-5 SWPPP DETAILS
C-6 SWPPP DETAILS
AS -101 ARCHITECTURAL SITE PLAN
C-7 SITE IMPROVEMENTS PLAN
C-8 GRADING & DRAINAGE PLAN
C-9 UTILITY PLAN
C-10 CIVIL DETAILS
C-11 UTILITY DETAILS
C-12 UTILITY DETAILS
S400 STRUCTURAL DETAILS
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:34 PM
GI-001
GENERAL
INFORMATION
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
dns
bht
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
Town of Hilton Head Island
OLD SCHOOLHOUSE PARK
TOILET FACILITY
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
11/15/2024 Town Pre-Application Submittal
3/31/2025 Town DPR Application
P1.0 PLU
ELECTRICAL
E-100 ELECTRICAL PLANS AND DETAILS
Page 21 of 46
FD
OCRM
CRITICAL
LINE
50.00' ACCESS EASEME
NT
(PER PB:45 PG:67)
±12LF
18" RCP @ 0.33%
ZONE X
(0.2% CHANCE)
FLOOD
ZONE X
FLOOD
ZONE X
ZONE X
(0.2% CHANCE)
ZONE X
(0.2% CHANCE)
ZONE AE
ELEV. 9'
CONCRETE SIDEWALK
CONCRETE
SIDEWALK
±168LF
30" RCP @ 0.23%
SDMH
RIM:9.92'
SUMP:3.52'
SED:3.89'
WSE:4.18'
(3-3-23)
IE(SE):4.20'
IE(S):4.29'
IE(NW):4.21'
GI
RIM:8.10'
SUMP:4.25'
IE(N):4.25'
±172LF
30" RCP @ 0.19%
GI
RIM:8.96'
IE(N):CNA
±9LF
18" RCP
SDMH
RIM:11.14'
SUMP:4.34'
SED:4.62'
WSE:4.85'
(3-3-23)
IE(SE):4.72'
IE(NW):4.56'
IE(N):4.70'
ARVMH
(FMMH)
RIM:9.97'
PD
FORCE MAIN
PD
4" PVC
18 MAG
18 LA
31 LO
14 SYC
11 9 HO
10 HO
16 HO
17 P
13 PAL
18 CED
15 10 9 HO
14 8 SB
11 7 HO
12 8 6 HO
9 6 MAG
16 SYC
17 LO
12 11 WO
21 SYC
8 HO
8 5 HO
19 LO
13 9 7 HO
11 PAL
8 6 HO
31 LO
28 SYC
7 6 HO
26 LO
14 PAL
13 SYC
11 PAL
16 LO
13 PAL
15 PAL
40 SYC
9 PAL
14 LA
12 LO
17 CH
15 LA
13 LO
12 LO
34 LO
20 LO
17 LO
13 9 LA
10 LA
14 13 CH
13 LO
69 LO
8 LA
10 LA
29 23 LO
15 WO
10 WO
8 MAG
10 9 BP
72 LO
25 PEC
8 WO
20 SB
16 G 14 G
11 WO
9 P
29 LO
25 LO
16 LO
14 PAL
11 PAL 14 PAL
11 PAL
12 11 G
15 PAL
13 PAL
14 DEAD
10 G
42 LO
15 PAL
15 PAL
34 LO
16 LO
15 PAL
13 PAL
13 PAL
11 PAL
9 9 8 LO
16 PAL
28 LO
9 LA
29 LA
16 LA
15 PEC
12 LA 11 CH
10 CH
9 LA
9 LO
13 LA
12 WO 12 SYC
10 LA
13 12 11 LO 17 LA
11 WO
11 WO
24 LO
15 LO
24 LO
8 P 29 P
20 LO
15 G
12 PAL
23 DEAD
20 15 9 LO
19 DEAD
18 14 LO
12 LO
18 P
8 P
7 LO
17 LO
13 LA
9 LO 18 LO
18 LO
14 LO
14 LO
14 LO
10 DEAD
31 LA
16 PAL
13 LA
10 SB
13 LO
11 LA
13 PAL
7 LO
14 PAL
10 LO
7 9 LO
13 PAL
15 PAL
14 PAL
20 LO
12 PAL
29 LO
50 LO
21 LO
13 PAL
13 PAL
31 LA
20 9 LO
20 LO
14 WO
10 LO
10 LA
10 LO
17 LO 16 G
11 PAL
25 14 LO
20 20 16 15 LO
16 PAL
12 PAL
14 DEAD
14 LA
12 LO 19 LA
10 G
34 LO
12 PAL
15 LO 14 LO 22 LA
8 G
14 PAL
14 PAL
16 15 CH
8 6 MAP
8 LO
16 LO
15 LO
19 DEAD
12 G
10
10
11
10
10
11
12
12
12
11
10
11
8
9
7
6
5
11
10
5
8
7
55
6
9.52 9.08
8.97 8.97 8.97 9.43
10.1
9.6
10.27
9.94
10.28
11.1
10.5
9.73
9.8
9.10
9.54
9.4 9.5
9.35
9.31
9.88
9.74
9.5
10.4
10.1
9.9
10.27
10.09
10.3
10.16
9.9
9.9
9.59
10.01
10.53
10.6
10.77
9.7
9.96
9.80
10.80
10.65
10.68
10.50
10.58
10.76
11.0
10.67
10.72
10.92 10.99
10.97
10.92
11.6
11.0
11.5
10.96
11.6
11.5
11.1
11.0
10.7
10.9
11.1
11.0
10.53
10.7
11.2
11.3
11.34
11.29
11.4
11.1
10.74
10.59
11.9
10.6
9.19
10.38
9.07
10.50
9.08
10.36
11.0
9.9
9.8
10.37 10.02
9.86
9.6
9.8
10.24
10.9
11.1
10.63
10.13
10.51
11.29
11.83
11.30
11.45
10.96
11.32
11.18
11.19
11.23
11.48 11.07
11.2
11.09
11.01
11.31
11.7
11.3
11.29
11.29
11.5
11.4
11.6
12.0
11.8
11.7
11.37
10.95
9.93
11.0
11.3
11.6
11.4
11.6
11.7
11.5
11.1
11.0
11.9
11.8
12.0
11.8
11.6
11.7
12.2
11.51 11.5
11.51
11.76
11.49 11.5
12.0
11.9 12.2
11.73 11.7
11.9
11.8
13.0
11.9 11.9 11.9
12.0
12.0
11.7
11.5
11.6
12.0
11.8
11.3
11.1
11.6
11.9
11.3
11.5
11.3
11.3
11.4
11.5
10.9
11.4
10.8
11.1
11.6
11.43
10.76
10.7
10.9
11.5
11.4
11.7
11.5
11.3
11.4
11.7
11.3
11.5
10.9
11.2 11.3
11.8
11.4
11.2
9.9
10.3
9.0
9.1
11.0
11.2
10.5
9.4
11.2
11.0
11.3
10.2
5.9
9.2
4.2
10.4
10.5
4.9
5.5
8.9
8.0
5.2
5.7
6.6 4.7
6.3
7.4
4.2
11.4
11.5
10.83
11.01
10.84
9.9
10.6
10.8
9.5
10.0
10.51
9.5
9.5
10.43
4.3
3.9
5.0
8.5
7.1 6.8
6.3
7.0
5.4
4.9
9.3
9.0
8.8
8.6
9.2
9.9 9.4
9.5
9.1
9.4
8.0
6.7
7.0
8.2
4.5
4.3
3.3
6.6
5.9
6.3
7.7
7.4
6.1
4.3 4.2
8.8
8.3
7.3
6.3
6.0
2.9
4.1
3.8
8.1
3.9
3.9
3.9
BOC
WILLIAM HILTON PARKWAY
U.S. HIGHWAY 278 R/W VARIES
N/F
TOWN OF HILTON HEAD ISLAND
TMS R511 007 000 0070 0000
PB:45PG:67
DB:2410PG:2126
124,877 S.F.
2.867 AC.
N/F
KENNETH & MARGARETE JAMES
TMS R511 007 000 0072 0000
PB:33PG:18
DB:3204PG:2165
N/F
TUAN Q. NGUYEN
TMS R511 007 000 072D 0000
PB:36PG:180
DB:3140PG:178
N/F
BEAUFORT COUNTY
TMS R511 007 000 0247 0000
PB:45PG:67
162,556 S.F.
3.732 AC.
PICKLEBALL
COURT N/F
TOWN OF HILTON HEAD ISLAND
TMS R511 007 000 072A 0000
DB:3919PG:2593
BASKETBALL
COURT
N/F
HILTON HEAD CO INC.
TMS R510 007 000 0071 0000
DB:194PG:405
N/F
HEIRS OF HENRY SIMMONS
TMS R511 007 000 068G 0000
DB:163PG:90
N/F
DANIEL FRAZIER IV
TMS R511 007 000 0069 0000
PB:141PG:161
DB:4052PG:2726
PICKLEBALL
COURT
2.5' WOOD/ROPE FENCE
3' CHAINLINK
FENCE
CHAINLINK FENCE
3' WOOD FENCE
S46°45'53"W 322.44'
S78°18'22"E 469.62'
L1
323.69'
S46°46'01"W 72.42'
283.27'
S46°47'40"W 313.39'(T)
30.12'
L4
L3
L5
L7
L6
N46°53'22"E 661.84'(T)
L9
L8
L10
L13
L12
L11
L16
L15 L20
L19
L18 L17
L14
465.24' N78°54'19"W 477.46'(T)
L21
L23
L22
34.89'
L26
L25
L24
338.15'
ONE STORY
CONCRETE SIDED
BUILDING
FFE:12.24'
TWO STORY
WOOD SIDED
BUILDING
FFE:16.62'
TWO STORY
WOOD SIDED
BUILDING
FFE:14.68'
SHED
SBA
DYL
DWS
HOOP
HOOP
3X3" CMF
(BROKEN)
5X5"
CMF
5X5"
CMF
3X3"
CMF
TPED
SN
W
C
SN
D
C
SN
SN
SN
SN SN
SN
SN
AR
SSCO
SN
D
TR
TR
TR
TR
FFO T
F
TPED
W
IR
NEW TOILET AND
STORAGE BUILDING
EXISTING WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PROPERTY LINE
PROPERTY LINE
NEW HANDICAPPED
ACCESSIBLE
PARKING SPACE -
SEE CIVIL DRAWINGS
NEW SIDEWALK CONNECTING
PARKING AND PICKLEBALL AND TOILET
FACILITIES - SEE CIVIL DRAWINGS
EXISTING CONCRETE SIDEWALK
LOCATION OF FEMA FLOOD LINE
FEMA FLOOD LINE
FEMA FLOOD LINE
SEE CIVIL DRAWINGS FOR SILT FENCING,
TYPICAL PROVIDE SINGLE ROW SILT FENCE
AT PERIMETER OF WORK AREA IN
APPROXIMATE LOCATION SHOWN
(2) LOCP - LOROPETALUM CHINESE 'PURPLE
DIAMOND', COMMON NAME FRINGE FLOWER,
3 GAS, 24" -36" HEIGHT, 24" -36" SPREAD (3) POMA - PODOCARPUS
MACROPHYLLUS, COMMON NAME
JAPANESE YEW, 15 GAL, 30" -36"
HEIGHT, 24" -36" SPREAD
1. PARKING SPACES SHALL BE MARKED WITH WHITE PAINTE D LINES EXCEPT WHERE
ACCESSIBILITY REQUIREMENTS REQUIRE THAT SPACES BE DELINEATED IN BLUE.
2. PAINTED YELLOW LINES SHALL BE USED FOR MARKING N O PARKING AREAS.
3. HANDICAPPED PARKING SPACE SHALL BE MINIMUM 8' WI DE X 18' LONG WITH MINIMUM 8' WIDE X
18' LONG ACCESS AISLE IMMEDIATELY TO THE PARKING SP ACE.
PARKING NOTES
1. ALL TREES IN EXISTING BUFFER AREAS SHALL BE PRES ERVED.
2. WHERE GROUPINGS OF NATIVE SHRUBS ARE PRESENT IN EXISTING BUFFER AREAS THEY
SHALL BE PRESERVED WITH MINIMUM DISTURBANCE..
3. ANY CLEARING OR OTHER WORK OF ANY KIND IN EXISTI NG BUFFER AREAS MUST RECEIVE
PRIOR APPROVAL OF THE APPROPRIATE TOWN OFFICIAL.
4. IN ORDER TO PRESERVE EXISTING VEGETATION AND TO RESTRICT ACTIVITIES WITHIN AN
EXISTING BUFFER AREA, PROTECTIVE FENCING SHALL BE I NSTALLED IN ACCORDANCE WITH
TOWN OF HHI LMO SECTION 16-6-104.J, TREE AND BUFFER PROTECTION DURING DEVELOPMENT
ACTIVITIES.
5. EXISTING VEGETATION THAT IS PRESERVED SHALL NOT BE LIMBED UP FROM THE GROUND
MORE THAN FIVE FEET TO THE LOWEST BRANCHES, EXCEPT: A) VEGETATION AT
INTERSECTIONS MAY BE LIMBED UP TO A GREATER HEIGHT TO ENSURE COMPLIANCE WITH
LMO SECTION 16-5-105.H.4, SIGHT TRIANGLES; AND B) IF UNDERSTORY PLANTING IS PROPOSED,
APPROVAL MUST BE OBTAINED FROM THE APPROPRIATE TOWN OFFICIAL TO ALLOW EXISTING
VEGETATION TO BE LIMBED UP TO A HEIGHT THAT WILL PR OVIDE ADEQUATE SUNLIGHT TO
PLANTS.
BUFFER VEGETATION NOTES
1. TREE AND BUFFER PROTECTION ZONES SHALL INCLUDE T HE AREAS OF THE DEVELOPMENT
SITE THAT ARE WITHIN THE DRIP LINES OF THE INDIVIDU AL TREES AND STANDS OF TREES
THAT ARE TO BE RETAINED AND PROTECTED IN ACCORDANCE WITH LMO SECTION 16-6-104.F,
SPECIMEN AND SIGNIFICANT TREE PRESERVATION, SECTION 16-6-104.G, MINIMUM TREE
COVERAGE STANDARD, OR SECTION 16-6-104.K, TREE DAMAGE DURING DEVELOPMENT, AS
WELL AS ALL BUFFER AREAS TO BE PROTECTED IN ACCORDANCE WITH LMO SECTION
16-5-103.D, ADJACENT STREET BUFFER REQUIREMENTS AND SECTION 16-5-103.E, ADJACENT
USE BUFFER REQUIREMENTS.
2. ALL BUFFER AREAS MUST BE PROTECTED WITH RED LINE SILT FENCING, INSTALLED ON METAL
STAKES AND TREE PROTECTION FENCING, INCLUDING CAUTI ONARY SIGNAGE.
TREE AND BUFFER PROTECT. ZONE NOTES
1. PROVIDE TO THE TOWN AN EROSION AND SEDIMENT CONT ROL PLAN PER TOWN OF HHI LMO
SECTION 16-5-109.I.
2. PER TOWN OF HHI LMO SECTION 16-5-109.I.2.D, ALL EROSION, SEDIMENTATION, AND POLLUTION
CONTROL BMP'S SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THE
SOUTH CAROLINA DHEC'S STORMWATER BMP HANDBOOK.
3. ALL SYMBOLS AND STANDARD DETAILS SHALL CONFORM T O THOSE FOUND WITHIN THE BMP
HANDBOOK.
STORMWATER NOTES
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:34 PM
AS-101
ARCHITECTURAL SITE
PLAN
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
Author
Checker
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
SCALE: 1" = 30'-0" A1 SITE PLAN TRUE NORTH PLAN NORTH
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
11/15/2024 Town Pre-Application Submittal
3/31/2025 Town DPR Application
6/5/2025 Town DPR Revisions
Page 22 of 46
FD
AE -201 B4
AE -201
AE -201
A4
B1
C1
AE-201
AI -201
B5
24' - 2"
8' - 4"
1' - 6" 1' - 6"
STORAGE
2
TOILET RM
1
9' - 6" 14' - 2" 6"
T4 T6 T1A
T2
T1A
T1A
T7
T1B
T1C
HI/LO DRINKING FOUNTAIN
WITH BOTTLE FILLER - SEE
PLUMBING DRWGS
2A
1A
DOWNSPOUT AND
CONCRETE
SPLASHBLOCK
DOWNSPOUT AND
CONCRETE
SPLASHBLOCK
EDGE OF ROOF ABOVE
1' - 4"
10" 2"
EQ EQ
AE-601
B5
T3
SLOPE
SEE STRUCTURAL DRAWINGS
FOR CMU COLUMN
10"
2" 2"
2"
CONCRETE PORCH SLAB
TR. WOOD SILL BELOW
FIBER CEMENT SIDING - FULL HEIGHT
AT THIS WALL
17' - 4"
2" CONT. ALUM VENT
GUTTER AND
DOWNSPOUT SYSTEM -
SEE SPECIFICATIONS
GUTTER AND
DOWNSPOUT SYSTEM
3' - 8" 3' - 8"
3' - 8" 3' - 8"
DS
DS
OS
EXPOSED RAFTER TAILS
2' - 8"
2' - 8" 2' - 8"
2' - 0" 2' - 0"
EQ EQ
CL
1x4 TR. WD TRIM AT
PERIMETER
17 18
AE -201 B4
AE -201
AE -201
AE -201
A4
B1
A1
C1
AE-201
3:12 SLOPE 3:12 SLOPE
LINE OF WALL BELOW
STANDING SEAM METAL
ROOF - SEE SPECIFICATIONS
DS
DS
GUTTER AND DOWNSPOUT
SYSTEM, SEE SPECIFICATIONS
OS
RCP LEGEND
DOWN LIGHT
LINEAR LED FIXTURE
DUAL HEAD
EMERGENCY LIGHT
WALL MOUNTED
LIGHT FIXTURE
EXHAUST FAN
OCCUPANCY SENSOR
1/2" EXTERIOR GRADE
PLYWOOD FINISH
WITH 1/2" X 1 1/2"
BATTENS @ 4' O.C.
NOTE: SEE ALSO ELECTRICAL PLANS / SCHEDULES
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:31 PM
AE-101
PLANS
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
dns
bht
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
SCALE: 1/4" = 1'-0" A4 FLOOR PLAN
SCALE: 1/4" = 1'-0" A2 REFLECTED CEILING PLAN.
SCALE: 1/4" = 1'-0" C4 ROOF PLAN.
EXTERIOR MATERIAL COLOR SCHEDULE
(SEE ALSO SPECIFICATIONS)
SIDING
SIDING TRIM (SMOOTH)
WOOD STRUCTURE / CEILING
TABBY STUCCO
ROOF PANELS AND TRIM
HARDI PLANK - TIMBER BARK
HARDI PLANK - COBBLE STONE
CABOTS SEMI SOLID STAIN - BEECHWOOD GRAY
TO MATCH COLIGNY WATERFRONT PARK BUILDINGS
PAC-CLAD - ZINC
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
TRUE NORTH PLAN NORTH TRUE NORTH PLAN NORTH
TRUE NORTH PLAN NORTH
11/15/2024 Town Pre-Application Submittal
3/31/2025 Town DPR Application
Page 23 of 46
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
C1
AE-201
1A
BEAM - SEE STRUCTURAL
TABBY STUCCO FINISH AT CMU COLUMN
HI -LO DRINKING FOUNTAIN W/ BOTTLE
FILLER - SEE PLUMBING DRWGS
EXPOSED RAFTER TAILS
GUTTER AND DOWNSPOUT SYSTEM
STANDING SEAM METAL ROOF
SEE SCHEDULE FOR DOOR AND FRAME
SEE CIVIL DRWGS FOR
FINISHED GRADE
FIBER CEMENT LAP SIDING - 6" EXPOSURE
T.O.M.@ COLUMN
8' - 7 3/4"
DOWNSPOUT W/ CONC. SPLASH BLOCK
17 18
+/- 13' - 5 3/8"
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
C1
AE-201
STANDING SEAM METAL ROOF
GUTTER AND DOWNSPOUT SYSTEM
TO CONCRETE SPLASHBLOCK
EXJPOSED RAFTER TAILS
1X FIBER CEMENT BD. CORNER TRIM
FIBER CEMENT LAP SIDING - 6" EXPOSED
TR. WD. SILL
TABBY STUCCO FOUNDATION - SEE SPECIFICATIONS
SEE CIVIL DRAWINGS
FOR FINISHED GRADE
T.O.M.@ COLUMN
8' - 7 3/4"
17 18
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
2A
TABBY STUCCO - SEE SPECS
FIBER CEMENT
BOARD TRIM
HI/LO FOUNTAIN W/
BOTTLE FILLER -
SEE PLUMBING
FIBER CEMENT LAP
SIDING
GUTTER AND DOWNSPOUT SYSTEM
CONCRETE SPLASH BLOCK
FIBER CEMENT BOARD TRIM
TABBY STUCCO FINISH AT CMU COLUMN
SEE CIVIL DRAWINGS FOR FINISHED GRADE
3" / 12"
OPEN
2' - 0"
T.O.M.@ COLUMN
8' - 7 3/4"
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
AE-301
A5
AE-301
A3 2' - 8" 2' - 8"
FIBER CEMENT
CORNER TRIM BD
SEE STRUCTURAL DRAWINGS FOR TRUSS
SYSTEM
STANDING SEAM METAL ROOF - SEE
SPECIFICATIONS
GUTTER AND DOWNSPOUT SYSTEM -
SEE SPECIFICATIONS
SEE STRUCTURAL DRAWINGS FOR
CONCRETE SLAB AND FOUNDATION
SEE CIVIL DRAWINGS FOR GRADE TABBY STUCCO FINISH AT CMU COLUMN
SEE STRUCTURAL DRWGS FOR BEAM
SEE DOOR SCHEDULE
FOR DOOR AND FRAME
T.O.M.@ COLUMN
8' - 7 3/4"
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
-
---
3" / 12"
FIBER CEMENT LAP
SIDING, 6" EXPOSURE
TABBY BASE - SEE SPECS
TR. WOOD SILL
FIBER CEMENT
TRIM BOARD
GUTTER AND
DOWNSPOUT SYSTEM
TO CONCRETE
SPLASH BLOCK
OPEN TABBY STUCCO AT CMU COLUMN
T.O.M.@ COLUMN
8' - 7 3/4"
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:32 PM
AE-201
BUILDING ELEVATIONS
& SECTIONS
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
kn
dns
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
SCALE: 1/4" = 1'-0" A4 SOUTH BUILDING ELEVATION
SCALE: 1/4" = 1'-0" A1 NORTH BUILDING ELEVATION
SCALE: 1/4" = 1'-0" B1 EAST BUILDING ELEVATION
SCALE: 1/4" = 1'-0" C1 BUILDING SECTION
SCALE: 1/4" = 1'-0" B4 WEST BUILDING ELEVATION
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
11/15/2024 Town Pre-Application Submittal
3/31/2025 Town DPR Application
Page 24 of 46
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
FINISHED GRADE, SLOPE AWAY FROM
BUILDING - SEE CIVIL DRAWINGS
10" CMU - SEE STRUCTURAL DRAWINGS
AE-301
C5
TR. WOOD SILL
8" CMU - SEE STRUCTURAL DRWGS
2' - 0"
EXPOSED RAFTER TAILS
GUTTER AND DOWNSPOUT SYSTEM
TO CONCRETE SPLASH BLOCK
1X FIBER CEMENT TRIM BOARD FASCIA
2X TR. BLOCKING
METAL DRIP EDGE
EXTERIOR GRADE PLYWOOD SHEATHING -
SEE STRUCTURAL DRWGS
STANDING SEAM METAL ROOF - SEE SPECS
ROOF TRUSS - SEE STRUCTURAL
DRWGS
TR. 2X8'S - SEE STRUCTURAL DRWGS
1X4 TR. WD TRIM
1/2" EXTERIOR GRADE PLYWOOD WITH
1/2" X 1 1/2" BATTENS AT 4'-0" O.C.
BACKER ROD AND SEALANT
2" ALUMINUM VENT BETWEEN EVERY
OTHER RAFTER
1" FIBER CEMENT TRIM BOARD
BETWEEN RAFTERS
FIBER CEMENT BOARD LAP SIDING
(6" EXPOSED) - SEE SPECIFICATIONS
2X4 FRAMING BETWEEN RAFTERS
TABBY STUCCO OVER METAL LATH - SEE
SPECIFICATIONS
BACKER ROD AND SEALANT
DRIP SCREED
WEATHER BARRIER
1/2" SHEATHING ON 7/8" METAL HAT CHANNELS
SEE STRUCTURAL DRAWINGS FOR SLAB AND
FOUNDATION - BROOM FINISH AT SLAB
9 1/4"
3" / 12"
T.O.M.@ COLUMN
8' - 7 3/4"
45.00°
WATERPROOF MEMBRANE TO 15' MSL, (HENRY
AQUA -BLOCK WB HE784 OR APPROVED EQUAL) -
SEE ALSO SHEET S100, CONCRETE MASONRY NOTE
21
1ST FLOOR
0' - 0"
TOP OF MASONRY
9' - 4"
2' - 8" ROOF TRUSS - SEE STRUCTURAL DRWGS
EXTERIOR GRADE PLYWD SHEATHING -
SEE STRUCTURAL DRWGS
STANDING SEAM METAL ROOF - SEE
SPECIFICATIONS
METAL DRIP EDGE
GUTTER AND
DOWNSPOUT SYSTEM -
SEE SPECIFICATIONS
1X FIBER CEMENT
TRIM BOARD
FASCIA
2X TR. BLOCKING
EXPOSED RAFTER TAILS
1/2" EXTERIOR GRADE PLYWOOD W/
1/2" X 1 1/2" BATTENS AT 4' -0" O.C.
3/4" X 3 1/2" FIBER CEMENT TRIM BOARD
1X FIBER CEMENT TRIM BOARD, TYP.
TABBY STUCCO OVER METAL LATH AT CMU
COLUMN BEYOND
SEE STRUCTURAL DRAWINGS FOR
SLAB AND FOUNDATION
SEE CIVIL DRAWINGS FOR
SIDEWALKS
9 1/4"
3" / 12"
TR. 2X4 FRAMING BETWEEN RAFTERS
T.O.M.@ COLUMN
8' - 7 3/4"
2" CONT. ALUM VENT - SEE RCP
45.00°
8" CMU - SEE
STRUCTURAL DRAWINGS
7/8" METAL FURRING
CHANNELS
1/2" FIBERGLASS FACED
GYP SHEATHING
WEATHER BARRIER FIBER CEMENT LAP SIDING -
SEE SPECIFICATIONS
FLASHING
TR. WOOD SILL W/ DRIP EDGE
FLASHING - TURN UP BEHIND
WEATHER BARRIER 8" MIN
TABBY STUCCO SYSTEM - SEE
SPECIFICATIONS
10" CMU - SEE
STRUCTURAL DRAWINGS
BACKER ROD AND SEALANT
3"
1"
2"
3"
WATERPROOF
MEMBRANE TO 15' MSL -
SEE A5/AE -301
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:32 PM
AE-301
SECTIONS / DETAILS
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
kn
dns
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
SCALE: 3/4" = 1'-0" A5 WALL SECTION
SCALE: 3/4" = 1'-0" A3 SECTION AT COLUMN/BEAM
SCALE: 3" = 1'-0" C5 SILL DETAIL
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
3/31/2025 Town DPR Application
Page 25 of 46
F
SEE MECH
PLAN FOR
VENT SIZE
0' - 10" MIN.
6" MIN 6" MIN
(PR) F HM -1
7' - 0" 4"
2" 3' - 0" 2"
3' - 4"
7' - 4"
HM -2
7' - 0" 4"
2" 6' - 0" 2"
6' - 4"
7' - 4"
MIN
6"
MIN
6"
6"
MIN
6"
TO BASELINE OF BRAILLE CELLS
48" MIN / 60" MAX
FINISH FLOOR
PICTOGRAM, IF
APPLICABLE
TEXT/BRAILLE -
ADJUST SIZE
ACCORDING TO
LETTERING
SIGN LOCATION:
SINGLE DOOR - AT LATCH SIDE
DOUBLE DOOR - AT RIGHT
SIDE OF RIGHT HAND DOOR
NOTE:
ADJUST SIZE OF
SIGN FOR LARGE
PICTOGRAMS
AND/OR LETTERING
THAT WILL NOT FIT
ON STANDARD MIN.
SIZE.
EDGE OF DOOR
FRAME
HARDWARE SCHEDULE
SET 1 - PRIVACY
QTY. DESCRIPTION CAT. NUMBER MFR.
3 EA
1 EA
1 EA
1 EA
1 EA
1 EA
3 EA
1 EA
1 EA
HINGE
MORTISE LOCK
SURFACE CLOSER
PUSH PLATE
PULL
KICK PLATE
SILENCER
DOOR SWEEP
GASKETING
5BB1 4.5 X 4.5
ML2055 LWA GMK
4011
120L CFC
8303 4" X 16" CFT
8400 8" X 34" LDW B -CS
SR64
39A
188S PSA
IVES OR APPROVED EQUAL
CORBIN -RUSSWIN OR APPROVED EQUAL
LCN OR APPROVED EQUAL
HAGER OR APPROVED EQUAL
IVES OR APPROVED EQUAL
IVES OR APPROVED EQUAL
IVES OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
SET 2 - STORAGE
QTY. DESCRIPTION CAT. NUMBER MFR.
6 EA
2 EA
1 EA
1 EA
1 EA
2 EA
1 EA
HINGE
FLUSH BOLT
LOCKSET
RAIN DRIP
DOOR SEAL
DOOR SWEEP
THRESHOLD
5BB1 4.5 X 4.5
FB458
ML2057 LWA CMK MK VKC2
142AA 76"
188SBK 1 X 72" / 2 X 84"
39A 36"
655A 72" 223 -MSLA -10
IVES OR APPROVED EQUAL
IVES OR APPROVED EQUAL
CORBIN -RUSSWIN OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
ZERO OR APPROVED EQUAL
DOOR - SEE SCHEDULE
DOOR FRAME W/ MASONRY
ANCHOR - GROUT SOLID - SEE
DOOR SCHEDULE
8" CMU - SEE STRUCTURAL -
PROVIDE 8" OF SMOOTH FACED
CMU AT FLOOD PROTECTION
JAMB TRACK - MATCH COLOR OF
ADJACENT CMU
1" 5 3/4" EQ
SEALANT W/ BACKER ROD
1X FIBER CEMENT BOARD TRIM
FIBER CEMENT BOARD LAP
SIDING OVER 1/2" SHEATHING ON
7/8" METAL HAT CHANNELS
TR. WD. BLOCKING
LINE OF TABBY WALL BELOW
LINE OF TR. WD SILL BELOW
1" X 5 1/2" FIBER CEMENT BD TRIM
WATERPROOF MEMBRANE -
SEE A5/AE -301
SEALANT EA SIDE
7 1/4"
EQ
DOOR - SEE SCHEDULE
DOOR FRAME W/ MASONRY
ANCHOR - GROUT SOLID - SEE
DOOR SCHEDULE
SEALANT EA SIDE
8" CMU - SEE STRUCTURAL -
PROVIDE 8" OF SMOOTH FACED
CMU AT FLOOD PROTECTION
JAMB TRACK - MATCH COLOR OF
ADJACENT CMU
SEALANT W/ BACKER ROD
1X FIBER CEMENT BOARD TRIM
SEALANT W/ BACKER ROD
TABBY STUCCO SYSTEM - SEE
SPECIFICATIONS LINE OF TR. WD SILL ABOVE
10" CMU - SEE STRUCTURAL
DRWGS
WATERPROOF MEMBRANE -
SEE A5/AE -301
SEE STRUCTURAL DRAWINGS
FOR FLOOR SLAB
ALUMINUM THRESOLD SET IN
BED OF SEALANT
DOOR FRAME BEYOND - SEE
SCHEDULE
DOOR - SEE SCHEDULE
EMBEDDED SILL ANGLE BY FLOOD
PROTECTION MFR. - SEE ALSO
STRUCTURAL DRWGS - GENERAL
CONTRACTOR TO COORDINATE
REMOVABLE ALUMINUM FLOOD
PLANK
SILL GASKET BY FLOOD
PROTECTION MFR.
DOOR SWEEP AS SCHEDULED
0' - 4" 0' - 4"
CONCRETE STOOP - SEE PLAN;
SLOPE TO DRAIN
1/2" EXPANSION MATERIAL
SEE STRUCTURAL DRAWINGS
FOR FLOOR SLAB
ALUMINUM THRESOLD SET IN
BED OF SEALANT
DOOR FRAME BEYOND - SEE
SCHEDULE
DOOR - SEE SCHEDULE
EMBEDDED SILL PLATE BY FLOOD
PROTECTION MFR. - GENERAL
CONTRACTOR TO COORDINATE
REMOVABLE ALUMINUM FLOOD
PLANK
SILL GASKET BY FLOOD
PROTECTION MFR.
DOOR SWEEP AS SCHEDULED
0' - 4"
8" CMU - SEE STRUCTURAL
DRAWINGS
SEALANT BOTH SIDES
DOOR - SEE SCHEDULE
DOOR FRAME - GROUT
SOLID - SEE DOOR SCHEDULE
CMU LINTEL - SEE STRUCTURAL
EQ
1/2" SHEATHING ON 7/8" HAT
CHANNELS
FLASHING - EXTEND UP
BEHIND WEATHER
BARRIER 8" MIN.
SEALANT
BACKER ROD AND
SEALANT
FIBER CEMENT BOARD LAP
SIDING - 6" EXPOSED
1X FIBER CEMENT
BOARD TRIM
1" X 5 1/2" FIBER
CEMENT BD TRIM
DOOR - SEE SCHEDULE
DOOR FRAME W/ MASONRY
ANCHOR - GROUT SOLID - SEE
DOOR SCHEDULE
SEALANT EA SIDE
10" CMU - SEE STRUCTURAL
EQ
1" X 5 1/2" FIBER CEMENT
BOARD TRIM
SEALANT W/ BACKER ROD
FIBER CEMENT BOARD LAP
SIDING OVER 1/2" SHEATHING ON
7/8" METAL HAT CHANNELS
TR. WD. BLOCKING
1X FIBER CEMENT BOARD TRIM
WATERPROOF MEMBRANE -
SEE A5/AE -301
THE LINE SHOWN ABOVE IS
EXACTLY ONE INCH LONG AT THIS
SHEETS ORIGINAL PAGE SIZE
NOT FOR CONSTRUCTION
Drawing
DATE DESCRIPTION ∆
THE SQUARES ABOVE ARE COLOR, WITH BLACK
AND WHITE LETTERS, IF PRINTED CORRECTLY
M C Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
6/17/2025 12:49:33 PM
AE-601
DOOR SCHEDULE &
DETAILS
152 William Hilton Parkway
Hilton Head Island, South Carolina, 29926
Old Schoolhouse Park
Toilet Facility
Town of Hilton Head Island
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00
kn
dns
Issue Date
NOVEMBER 15, 2024
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
Door Schedule
Mark Door Type Thickness Width Height Material Finish
Frame
Type
Frame
Material
Frame
Finish Head Detail Jamb Detail Sill Detail
Hardware
Set Signage Comments
1A F 0' - 1 3/4" 3' - 0" 7' - 0" Steel Paint HM-1 HM Paint C5 /AE-601 B2/AE-601 A4/AE-601 1 X Provide ADA/ANSII compli ant pictogram signage for HC accessible
unisex toilet. See detail this sheet.
2A (PR) F 0' - 1 3/4" 6' - 0" 7' - 0" Steel Paint HM-2 HM Pa int C5/AE-601 B4/AE-601 /
B5/AE-601
A5/AE-601 2 X
SCALE: 1/4" = 1'-0" C3 DOOR/FRAME ELEVATIONS
SCALE: 1/2" = 1'-0" A1 SIGN MTG DTL
SCALE: 3" = 1'-0" B5 DOOR JAMB DETAIL AT SIDING
SCALE: 3" = 1'-0" B4
DOOR JAMB DETAIL AT
TABBY
SCALE: 3" = 1'-0" A5 DOOR SILL DETAIL
SCALE: 3" = 1'-0" A4 DOOR SILL DETAIL AT TLT.
SCALE: 3" = 1'-0" C5 DOOR HEAD DETAIL
SCALE: 3" = 1'-0" B2 DOOR JAMB DETAIL AT TLT.
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
3/31/2025 Town DPR Application
Page 26 of 46
FDFD
THE LINE SHOWN ABOVE ISEXACTLY ONE INCH LONG AT THISSHEETS ORIGINAL PAGE SIZE
FOR PERMIT
Drawing
DATEDESCRIPTION¨
THE SQUARES ABOVE ARE COLOR, WITH BLACKAND WHITE LETTERS, IF PRINTED CORRECTLYMCYK
ARCHITECT
Project Number:Drawn By:Checked By:
+RUG&RSODQ0DFKW,QF
A
B
C
D
12345
1/16/2025 4:10:39 PM
152 William Hilton ParkwayHilton Head Island, South Carolina, 29926
Old Schoolhouse ParkToilet FacilityTown of Hilton Head Island
CIVIL ENGINEER1536 Fording Island RoadSTRUCTURAL ENGINEER110 Traders Cross, Second FloorMECHANICAL AND PLUMBING ENGINEER110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00------
Issue DateNOVEMBER 20, 2024
ELECTRICAL ENGINEERP.O. Box 2869CDDC, LLCBluffton, SC 29910843.384.4731
ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN
10 PALMETTO BUSINESS PARK+,/721+($',6/$1'6&843.785.2199HORD COPLAN MACHT
DESIGNDRAFTCONSULTCONSTRUCT
E-100ELECTRICAL PLANS ANDDETAILS
Page 27 of 46
New Town of Hilton Head Island
Old Schoolhouse Park Toilet Facility
150 & 152 William Hilton Parkway
Design Review Board (DRB) Photographs of Existing Facility New Building will Match
View of existing facility on Cordillo Parkway that new building will match.
View of existing facility on Cordillo Parkway that new building will match.
Page 28 of 46
New Town of Hilton Head Island Old Schoolhouse Park Toilet Facility
Design Review Board (DRB) Photographs of Existing Facility New Building will Match
Page 2 of 2
View of existing facility on Cordillo Parkway that new building will match.
View of existing facility on Cordillo Parkway that new building will match.
Page 29 of 46
Page 30 of 46
XTOR
CROSSTOUR LED
APPLICATIONS:
WALL / SURFACE
POST / BOLLARD
LOW LEVEL
FLOODLIGHT
INVERTED
SITE LIGHTING
Lumark
SPECIFICATION FEATURES
Construction
Slim, low-profile LED design
with rugged one-piece, die-cast
aluminum hinged removable door
and back box. Matching housing
styles incorporate both a small
and medium design. The small
housing is available in 12W, 18W
and 26W. The medium housing
is available in the 38W model.
Patented secure lock hinge feature
allows for safe and easy tool-less
electrical connections with the
supplied push-in connectors. Back
box includes three half-inch, NPT
threaded conduit entry points. The
universal back box supports both
the small and medium forms and
mounts to standard 3-1/2” to 4”
round and octagonal, 4” square,
single gang and masonry junction
boxes. Key hole gasket allows
for adaptation to junction box or
wall. External fin design extracts
heat from the fixture surface. One-
piece silicone gasket seals door
and back box. Minimum 5” wide
pole for site lighting application.
Not recommended for car wash
applications.
Optical
Silicone sealed optical LED
chamber incorporates a custom
engineered mirrored anodized
reflector providing high-efficiency
illumination. Optical assembly
includes impact-resistant
tempered glass and meets IESNA
requirements for full cutoff
compliance. Available in seven
lumen packages; 5000K, 4000K and
3000K CCT.
Electrical
LED driver is mounted to the
die-cast housing for optimal heat
sinking. LED thermal management
system incorporates both
conduction and natural convection
to transfer heat rapidly away from
the LED source. 12W, 18W, 26W
and 38W series operate in -40°C to
40°C [-40°F to 104°F]. High ambient
50°C models available. Crosstour
luminaires maintain greater than
89% of initial light output after
72,000 hours of operation. Three
half-inch NPT threaded conduit
entry points allow for thru-branch
wiring. Back box is an authorized
electrical wiring compartment.
Integral LED electronic driver is
standard 0-10V dimming. 120-277V
50/60Hz or 347V 60Hz models.
Finish
Crosstour is protected with a
Super durable TGIC carbon
bronze or summit white polyester
powder coat paint. Super durable
TGIC powder coat paint finishes
withstand extreme climate
conditions while providing optimal
color and gloss retention of the
installed life. Options to meet Buy
American and other domestic
preference requirements.
Warranty
Five-year warranty.
The patented Lumark Crosstour™ LED Wall Pack Series of luminaries
provides an architectural style with super bright, energy efficient LEDs.
The low-profile, rugged die-cast aluminum construction, universal back
box, stainless steel hardware along with a sealed and gasketed optical
compartment make the Crosstour impervious to contaminants. The
Crosstour wall luminaire is ideal for wall/surface, inverted mount for
façade/canopy illumination, post/bollard, site lighting, floodlight and low
level pathway illumination including stairs. Typical applications include
building entrances, multi-use facilities, apartment buildings, institutions,
schools, stairways and loading docks test.
DESCRIPTION
12W, 18W, 26W
5-3/4" [146mm]
38W
6-5/8" [168mm]
12W, 18W, 26W
6-3/4" [171mm]
38W
8" [203mm]
12W, 18W, 26W
3-5/8" [92mm]
38W
4" [102mm]
DIMENSIONS
CERTIFICATION DATA
Dark Sky Approved (Fixed mount, Full
cutoff, and 3000K CCT only)
UL/cUL Wet Location Listed
LM79 / LM80 Compliant
ROHS Compliant
ADA Compliant
NOM Compliant Models
IP66 Ingressed Protection Rated
Title 24 Compliant
DesignLights Consortium® Qualified*
TECHNICAL DATA
40°C Maximum Ambient Temperature
External Supply Wiring 90°C Minimum
EPA
Effective Projected Area (Sq. Ft.):
XTOR1B, XT0R2B, XT0R3B=0.34
XTOR4B=0.45
SHIPPING DATA:
Approximate Net Weight:
3.7 – 5.25 lbs. [1.7 – 2.4 kgs.]
10" [254mm]
17-1/2" [445mm]
10"
[254mm]
17-1/2"
[445mm]
ESCUTCHEON PLATES
*www.designlights.org
Catalog # Type
Date
Project
Comments
Prepared by
TD514013EN
December 14, 2021 5:27 PM
AVAIL ABLE
COMPLIANT OPTIONS
BAA
BUY AMERICAN ACT
Fixture B
Page 31 of 46
Project Catalog # Type
Prepared by Notes Date
PS51889024 page 1
April 1, 2025 5:22 PM
Top Product Features
• Round 5"/6" Recessed LED Trims suitable for new construction, remodel, and retrofit installation in most 5" or 6" IC
(insulation contact) or non-IC housings
• Lens & Trim: Recessed baffle or smooth splay trims with smooth flat diffuse lens
• 5-Color Field-SeleCCTable: 2700K, 3000K, 3500K, 4000K, 5000K; 90+ CRI
• Brightness: 750 or 1200 lumen versions (nominal)
• Dimming: Dims to 10% (phase cut LE/TE); 120V input
• Includes preinstalled torsion springs, orange LED Quick Connect and E26 medium socket adapter
• Meets AIR-TITE and code compliance for additional energy savings
• Life: 35,000 hrs of maintenance-free operation in damp or wet locations
• 5-year warranty
Interactive Menu
• Order Information page 2
• Product Specifications page 3
• Energy Data page 3
• Photometric Data page 4
• Product Warranty
• Dimming Guide
LT56 5"/6" Recessed LED Trims
These L T LED Trims are ideal for quickly installing energy-saving
downlighting in 5" and 6" recessed housings. The L T Series offers
5-color seleCCTable™ technology with flicker-free dimming to 10%.
The safe, non-conductive dead-front trims come in baffle or smooth
splay options. Decorative overlays are also available in 4 finishes.
Typical Applications Residential
Dimensional and Mounting Details
Installs in 5" or 6" housings
Package includes: E26 Screw Base Adapter
L T56 L T56
High-Lumen
LT56 DOB - 750 Lumen
LT56 - 1200 Lumen
FIXTURE HEIGHT
3.41"
[86 mm]
TRIM FLANGE
ø 7.19"
[182.67 mm]
FIXTURE HEIGHT
2.18"
[55.40 mm]
LENS REGRESSION
0.74"
[18.76 mm]
LENS REGRESSION
0.76"
[19.40 mm]
LT56 -
LT56 - Baffle
LT56 DOB - 750 Lumen
LT56 - 1200 Lumen
FIXTURE HEIGHT
3.41"
[86 mm]
TRIM FLANGE
ø 7.19"
[182.67 mm]
FIXTURE HEIGHT
2.18"
[55.40 mm]
LENS REGRESSION
0.74"
[18.76 mm]
LENS REGRESSION
0.76"
[19.40 mm]
TRIM FLANGE
7.22"
[183 mm]
LT56
LT56 - Baffle
L T56 -750 Lumen
L T56 -1200 Lumen
TRIM FLANGE
ø 7.19"
[182.67 mm]
FIXTURE HEIGHT
2.18"
[55.40 mm]
APERTURE
OPENING
ø 4.88"
[124 mm]
APERTURE
OPENING
ø 4.85"
[123 mm]
LT56 - Baffle LTSS56 - Smooth Splay
LT56 - Baffle LTSS56 - Smooth Splay
Can be used to comply
with Title 24 Part 6 LED
Enclosed Light Source
Requirements (JA8)
Refer to ENERGY STAR® Certified Products List.
Can be used to comply with California Title 24 High Efficacy requirements.(1)
Certified to California Appliance Efficiency Database under JA8.(1)
DEAD
FRONT
1. T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification.
Fixture C
Page 32 of 46
LT56 5"/6" Recessed LED Trims
PS51889024 page 2
April 1, 2025 5:22 PM
Order Information
A complete downlight consists of an integrated LED trim and a recessed housing (order separately).
Catalog Number Module Lumens CRI/CCT Finish Packaging
L T56079FS1EWHR 5/6 inch LED retrofit module with baffle trim 750 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White Recyclable
L TSS56079FS1EWHR 5/6 inch LED retrofit module with smooth splay trim 750 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White Recyclable
L T56129FS1EWHR 5/6 inch LED retrofit module with baffle trim 1200 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White Recyclable
L TSS5612FS1EWHR 5/6 inch LED retrofit module with smooth splay trim 1200 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White Recyclable
Catalog Number Module Lumens CRI/CCT Finish Packaging
L T56079FS1EWHR4PK 5/6-inch Recessed Baffle LED Trim 750 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White 4 pack, Recyclable
L T56079FS1EWHR6PK 5/6-inch Recessed Baffle LED Trim 750 lumen 90+ CRI, field selectable CCT: 2700K,
3000K, 3500K, 4000K, 5000K Matte White 6 pack, Recyclable
Optional Accessories - Decorative Baffle Trim Overlays (sold separately)
Catalog Number Description
L T56OMWB 5/6-inch Overlay, Paintable Matte White
L T56OMBB 5/6-inch Overlay, Matte Black
L T56OSNB 5/6-inch Overlay, Satin Nickel
L T56OTBZ 5/6-inch Overlay, Tuscan Bronze
HE26LED Replacement medium E26 screw base adapter (1 is already included with unit)
ML7RAB Retrofit Adapter Band – use with existing 5" & 6" housings that do not have
torsion spring receivers
Multi-packs
Individuals
L T56OMWB
White (Paintable),
Baffle
L T56OMBB
Matte Black,
Baffle
L T56OSNB
Satin Nickel,
Baffle
L T56OTBZ
Tuscan Bronze,
Baffle
HALO - 6" Housings 1
HALO LED H750ICAT, H750RICAT, H750T, H750TCP , H2750ICAT, H2750RICAT, H550ICAT, H550RICAT, E550ICAT, E550RICAT, E750ICAT,
E750RICAT
Standard Housing H7ICAT, H7ICT, H7T, H7ICATNB, H7ICTNB, H7TNB, H7UICAT, H7TCP , H7RICAT, H7RICT, H7RT, E7ICAT, E7ICATNB, E7RICAT, E7RTAT,
E7TAT, E7TATNB, H7UICAT, H7ICATNB, H7ICTNB, H7TNB, H7UICAT
Shallow Housing H27ICAT, H27RICAT, H27ICT, H27RICT, H27T, H27RT, EI2700AT, EI2700, EI2700R, ET2700, ET2700R, E27ICAT, E27RICAT,
E27TAT, E27RTAT
Fire Rated Housing H750FR2ICATD010
HALO - 5" Housings 1
Halo LED H550ICAT, H550RICAT, E550ICAT, E550RICAT
Standard Housing H5ICAT, H5ICATNB, H5RICAT, H5T, H5TNB, H5RT, E5ICAT, E5ICATNB, E5RICAT, E5RTAT, E5TAT, E5TATNB
Shallow Housing H25ICAT, H25RICAT, H25ICATNB
Fire Rated Housing H550FR2ICATD010
Juno
Standard Housing IC22, IC22R, IC22W, IC22S, IC23,
IC23W, TC2, TC2R, IC2
Shallow Housing IC21, IC21R
Capri
Standard Housing CR1, PR1, QL1
Shallow Housing R9ASIC/PS9RM
Elco HL7ICA (EL7ICA)
Thomas PS1
Commercial Electric C7ICA, H3
LUMINAIRES - UL Classified for retrofit compatibility
ote: N Compatible with any 5" or 6" diameter recessed luminaire with an internal volume that exceeds 115 in 3 in addition to those listed below.
Compatible Housings
Lithonia
Lighting
Standard Housing LC6, L7X
Shallow Housing L7XP
Progress
Lighting
Standard Housing P87-AT† *
Shallow Housing P86TG
Lightolier 1104ICS† *, 1104ICR† *
1. This fixture is UL Certified for use with any 5" or 6" diameter recessed luminaire constructed of
steel or aluminum with an internal volume that exceeds 107.9 in 3 addition to those noted below
and does not exceed the input rating of the luminaire.
Page 33 of 46
LT56 5"/6" Recessed LED Trims
PS51889024 page 3
April 1, 2025 5:22 PM
Specification Features
Module
• The LED module consists of an LED array, optical
assembly, driver, and self-flanged trim
• Round recessed baffle or smooth splay trim and
smooth flat lens
• Integral aluminum heat sink provides passive
thermal cooling achieving L70 at 35,000 hrs in IC
(insulation contact) and non-IC applications
LED Array
• Color Temperature (CCT): Available in 5-color
seleCCTable CCT: 2700K, 3000K, 3500K, 4000K,
5000K (soft white, bright white, neutral white, cool
white, daylight)
• Mid-power LED array provides a uniform light
source with high efficiency, long life, and no
pixilation
• 90+ CRI minimum, R9 greater than 50
• Color accuracy at 4 SDCM in between endpoints
provides color consistency and uniformity
Optical Assembly
• Optical assembly provides wide light distribution –
useful for general area and task lighting
• Diffuse injection molded lens with smooth flat
profile
• Meets ENERGY STAR® color angular uniformity
requirements
Driver
• Integral 120V 60Hz constant current driver
provides noise-free, high-efficiency operation
• Dimmable: Continuous, flicker-free dimming from
100% to 10% with compatible leading or trailing
edge (LE/TE) 120V phase cut dimmers. (See
Dimming Guide for compatible dimmers.)
Tip: For optimal dimming performance,
consider dimmers with low-end trim
adjustment; note that some dimmers require a
neutral wire in the box
• Wiring: Includes inline electrical orange LED Quick
Connect and E26 medium socket adapter provides
mains connections
• A separate ground wire and mounting hardware
ensures proper ground connection to housing
Retention
• Preinstalled steel torsion springs hold the module
securely in the housing (requires torsion spring
receivers)
• Ships with torsion springs in the 6" position,
adjusts to 5" position with two Phillips-head
screws
Trim
• The one-piece step baffle or smooth splay and
self-flanged trim ring provide lens regression and
reduced light leaks
• Injection molded plastic construction is impact-
resistant and non-corrosive
• Non-conductive construction meets most local
dead-front code requirements
Gasket
• Due to the HALO L T/L TE design, a gasket is not
required to achieve AIR-TITE code requirements
(caulking can be used for additional sealing if
necessary for local code)
Compliance
• UL Certified for US and Canada, type IC suitable for
UL-Certified for US and Canada, type IC suitable for
direct contact with air permeable insulation
• UL-Certified for US and Canada for use with HALO
housings, classified for use with others’ housings;
see instruction sheet for conditions of acceptability
• Wet location-listed and IP66 ingress protection-
rated
• Airtight per ASTM-E283
• Suitable for use in clothes closets when installed
in accordance with the NEC 410.16 spacing
requirements
• EMI/RFI emissions per FCC47CFR Part 15
consumer limits
• Contains no mercury or lead and is RoHS
compliant¹
• Photometric testing in accordance with IES
LM-79-08
• Lumen maintenance projections in accordance
with IES LM-80-08 and TM-21-11
• Can be used for State of California Title 24 high-
efficacy luminaire compliance; reference the
California Energy Commission Title 20 Appliance
Efficiency Database for current listings¹
• ENERGY STAR® listed; reference database for
current listings
• Meets State of California voluntary lamp standards
• Lighting Facts labeled
Warranty
• Five year limited warranty, consult website for
details. www.cooperlighting.com/warranty
Energy Data
LT56 DOB - 750 Lumen LT56 - 1200 Lumen
Lumens 750LM
Input Voltage 120V
Input current 0.065A
Input Power 8.75W
Efficiency 63.50%
Inrush(A) 3.74
THD 25.70%
PF 0.966
T Ambient -30 - +40°C
Sound Rating 18.024dB @1feet
Lumens 1200LM
Input Voltage 120V
Input current 0.105A
Input Power 12.4W
Efficiency 84.00%
Inrush(A) 2.9
THD 14.50%
PF 0.97
T Ambient -30 - +40°C
Sound Rating 20.2db@30cm
1. T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification.
Page 34 of 46
LT56 5"/6" Recessed LED Trims
PS51889024 page 4
April 1, 2025 5:22 PM
Photometric Data
22CZ2-24-UNVL830-CD1-U
Electronic Driver
Linear LED 5000K
Spacing criterion: (II) 1.23 x mounting
height, (⊥) 1.23 x mounting height
Lumens: 11493
Input Watts: 87.7W
Efficacy: 131.1 LPW
Test Report: 22CZ2-24-UNVL830-
CD1-U.IES
0-deg 45-deg 90-deg
180° 170°160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°20°10°0°
365
274
183
91
0
LT56079FS1EWHR_3000K
Spacing Criteria (0/90/45):
1.17 / 1.17 / 1.27
Beam Angle: 95.7O
Field Angle: 141.4O
Lumens: 795
Input Watts: 8.6 W
Efficacy: 92.4 LPW
UGR: 22.6
Test Report: P798568
Zonal Lumen Lumens % Lumens
0-30 273.2 34.4
0-40 435.2 54.7
0-60 708.2 89.1
0-90 794.1 99.9
TM-30-15
Rf = 92
Rg = 101
CRI/CIE
Ra = 93
R9 = 83.2
94°
CCT - Range of 2700K- 5000K
Lumens 795
Watts 8.6
Lumens Per Watt (Efficacy) 92.4
Color Accuracy (CRI) 93
PRODUCT
SPECIFICATIONS
2700K 3000K 4500K 6500K
Light Color (CCT) 3000K
Correlated Color Temperature (CCT)
warm white soft white bright white
LT56079FS1EWHR_3000KLT56 5CCT
CCT Watts lumens LPW CRI
2700K 8.5 760 89.4 93
3000K 8.6 795 92.4 93
3500K 8.0 790 98.8 93
4000K 8.5 795 93.5 93
5000K 8.0 780 97.5 93
22CZ2-24-UNVL830-CD1-U
Electronic Driver
Linear LED 5000K
Spacing criterion: (II) 1.23 x mounting
height, (⊥) 1.23 x mounting height
Lumens: 11493
Input Watts: 87.7W
Efficacy: 131.1 LPW
Test Report: 22CZ2-24-UNVL830-
CD1-U.IES
0-deg 45-deg 90-deg
180° 170°160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°20°10°0°
364
273
182
91
0
LTSS56079FS1EWHR_3000K
Spacing Criteria (0/90/45):
1.17 / 1.17 / 1.26
Beam Angle: 94.8O
Field Angle: 141.6O
Lumens: 789.7
Input Watts: 8.7 W
Efficacy: 90.8 LPW
UGR: 22.7
Test Report: P798563
Zonal Lumen Lumens % Lumens
0-30 273.4 34.6
0-40 434.2 55.0
0-60 703.1 89.0
0-90 788.9 99.9
TM-30-15
Rf = 92
Rg = 101
CRI/CIE
Ra = 93
R9 = 83.4
94°
CCT - Range of 2700K- 5000K
Lumens 790
Watts 8.7
Lumens Per Watt (Efficacy) 90.8
Color Accuracy (CRI) 93
PRODUCT
SPECIFICATIONS
2700K 3000K 4500K 6500K
Light Color (CCT) 3000K
Correlated Color Temperature (CCT)
warm white soft white bright white
LTSS56079FS1EWHR_3000KLT56 5CCT
CCT Watts lumens LPW CRI
2700K 8.5 770 90.6 93
3000K 8.7 790 90.8 93
3500K 8.0 810 101.3 93
4000K 8.5 810 95.3 93
5000K 8.5 790 92.9 93
Page 35 of 46
LT56 5"/6" Recessed LED Trims
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P : 770-486-4800
www.cooperlighting.com
© 2025 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions
subject to change without notice.
PS51889024 page 5
April 1, 2025 5:22 PM
22CZ2-24-UNVL830-CD1-U
Electronic Driver
Linear LED 5000K
Spacing criterion: (II) 1.23 x mounting
height, (⊥) 1.23 x mounting height
Lumens: 11493
Input Watts: 87.7W
Efficacy: 131.1 LPW
Test Report: 22CZ2-24-UNVL830-
CD1-U.IES
0-deg 45-deg 90-deg
180° 170°160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°20°10°0°
536
402
268
134
0
LT56129FS1EWHR-3000K
Spacing criterion:
(0-180) 1.22 | (90-270) 1.20 |
(Diagonal) 1.28
Beam Angle: 92.9°
Field Angle: 93.6°
Lumens: 1127
Input Watts: 12 W
Efficacy: 94 LPW
UGR: 21.5
Test Report: P600898
Zonal Lumen Lumens % Lumens
0-30 405.9 36
0-40 646.3 57.3
0-60 1019.8 90.5
0-90 1123.7 99.7
TM-30-15
Rf = 92
Rg = 103
CRI/CIE
Ra = 96.5
R9 = 85.2
93°
CCT - Range of 2700K- 5000K
22CZ2-24-UNVL830-CD1-U
Electronic Driver
Linear LED 5000K
Spacing criterion: (II) 1.23 x mounting
height, (⊥) 1.23 x mounting height
Lumens: 11493
Input Watts: 87.7W
Efficacy: 131.1 LPW
Test Report: 22CZ2-24-UNVL830-
CD1-U.IES
0-deg 45-deg 90-deg
180° 170°160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°20°10°0°
536
402
268
134
0
LTSS5612FS1EWHR-3000K
Spacing criterion:
(0-180) 1.22 | (90-270) 1.20 |
(Diagonal) 1.28
Beam Angle: 92.9°
Field Angle: 93.6°
Lumens: 1127
Input Watts: 12 W
Efficacy: 94 LPW
UGR: 21.5
Test Report: P600898
Zonal Lumen Lumens % Lumens
0-30 405.9 36
0-40 646.3 57.3
0-60 1019.8 90.5
0-90 1123.7 99.7
TM-30-15
Rf = 92
Rg = 103
CRI/CIE
Ra = 96.5
R9 = 85.2
93°
CCT - Range of 2700K- 5000K
Lumens 1345
Watts 12.2
Lumens Per Watt (Efficacy) 110.2
Color Accuracy (CRI) 93
PRODUCT
SPECIFICATIONS
2700K 3000K 4500K 6500K
Light Color (CCT) 3000K
Correlated Color Temperature (CCT)
warm white soft white bright white
LT56129FS1EWHR-3000K
Lumens 1345
Watts 12.2
Lumens Per Watt (Efficacy) 110.2
Color Accuracy (CRI) 93
PRODUCT
SPECIFICATIONS
2700K 3000K 4500K 6500K
Light Color (CCT) 3000K
Correlated Color Temperature (CCT)
warm white soft white bright white
LTSS5612FS1EWHR-3000K
LT56 5CCT
CCT Watts lumens LPW CRI
2700K 12.7 1230 96.9 93
3000K 12.2 1345 110.2 93
3500K 12.1 1385 114.5 93
4000K 12.3 1380 112.2 93
5000K 12.6 1290 102.4 93
LT56 5CCT
CCT Watts lumens LPW CRI
2700K 12.7 1230 96.9 93
3000K 12.2 1345 110.2 93
3500K 12.1 1385 114.5 93
4000K 12.3 1380 112.2 93
5000K 12.6 1290 102.4 93
Page 36 of 46
Project Catalog # Type
Prepared by Notes Date
TD505137EN page 1
June 23, 2020 8:25 AM
Top Product Features
• Long life LED source with rotatable optics
• Labor-saving automatic self-diagnostic for NFPA testing
• 29 feet to 50 feet of emergency egress coverage
• UL924 listed for wet location; NYC and Chicago Compliant
• Multi-voltage input 120/240/277 VAC
• Mullion-mount option
Interactive Menu
• Order Information page 2
• Photometric Data page 2
• Product Warranty
Dimensional Details
additional
product diagrams
Typical Applications
Office • Education • Healthcare • Hospitality • Retail • Industrial
Sure-Lites
SELDWA Emergency Light
LED Emergency Light
Wet Location
AccuLED Optic
Self Diagnostics
Black
Silver
White
Bronze
Product Certification
Product Features
7 .9375"
[202mm]
7 .875"
[200mm]
2.1875"
[56mm]
operating
temperature
range
Fixture OEM
Page 37 of 46
SELDWA Emergency Light
TD505137EN page 2
June 23, 2020 8:25 AM
Ordering Information
SAMPLE ORDER NUMBER: SELW25BZ
Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog
Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog
SELD W=Wet location. __=0 C to 40 C A=Architectural 50=50 ft. __=Silver
BZ=Bronze
BK=Black
WH=White
SD=self diagnostics
(standard)
SELDWA50SD
SELDWA50BZSD
SELDWA50BKSD
SELDWA50WHSD
Series Wet Location Temperature Type Coverage Color Self Diagnostics Catalog
SELD W=Wet location. T=-20 C to 55 C A=Architectural 29=29 ft. __=Silver
BZ=Bronze
BK=Black
WH=White
SD=self diagnostics
(standard)
SELDWTA29SD
SELDWTA29BZSD
SELDWTA29BKSD
SELDWTA29WHSD
Product Specifications
Electrical
• Dual Voltage Input 120/277 VAC, 60Hz
• Brownout circuit
• Low voltage disconnect
• Overload / Short Circuit protection
• 4.8V Battery back-up
• 100 Lumen LED = 1.1 watts
• 300 Lumen LED = 4.1 watts
Environmental
• Outdoor rated
• SELDWA50: 0 °C to 40 °C (32 °F to 104 °F)
• SELDWTA29: -20 °C to 55 °C (-4 °F to 131 °F)
Housing Construction
• Die cast aluminum housing
• White, black, silver, or bronze textured finish
• Snap-fit construction to facilitate fast installation
• Suitable for wall mount or conduit mount
applications
• Universal J-box mounting pattern
• Keyhole mounting slots
• Aesthetically designed with a thin profile
• Sealed and gasketed for Wet Location use
Battery
• Sealed Nickel Cadmium
• Full Recharge Time, 24 hours (max.)
• Mullion-mount option enabled with the
SELDWAMMKIT accessory
Warranty
• Five-year warranty
• Seven year pro-rated battery warranty
Code Compliance
• UL924 Wet Location Listed
• Life Safety NFPA 101
• NEC/OSHA
• Most State & Local Codes
• California Energy Code
• NYC compliant
• SELDWA50 series is City of Chicago compliant
Accessory
SELDWAMMKIT enables mullion mounting and is ordered separately.
Electrical Data
120V 277V
Model Power (W) Current (A) PF Power (W) Current (A) PF
All Models 2.0 0.3 0.07 1.8 0.21 0.03
Photometry
X Y Z Orient Tilt Roll
-0.25 0.5 7.5 90 7 1
0.25 0.5 7.5 90 7 -1
28.75 0.5 7.5 90 7 1
29.25 0.5 7.5 90 7 -1
57.75 0.5 7.5 90 7 1
58.25 0.5 7.5 90 7 -1
-29.25 0.5 7.5 90 7 1
-28.75 0.5 7.5 90 7 -1
SELDWTA29
calc grid in between fixtures
Illuminance (Fc)
Average = 1.03
Maximum = 1.5
Minimum = 0.2
Avg/Min Ratio = 5.15
Max/Min Ratio = 7.50
Spacing Stat Area
calc grid in between fixtures
Illuminance (Fc)
Average = 1.03
Maximum = 1.5
Minimum = 0.2
Avg/Min Ratio = 5.15
Max/Min Ratio = 7.50
Spacing Stat Area
29ft
Arrangement Total Lamp Lumens LLF Description
SINGLE N.A. 0.912 LEM
X Y Z Orient Tilt Roll
-0.25 0.5 7.5 90 7 1
0.25 0.5 7.5 90 7 -1
28.75 0.5 7.5 90 7 1
29.25 0.5 7.5 90 7 -1
57.75 0.5 7.5 90 7 1
58.25 0.5 7.5 90 7 -1
-29.25 0.5 7.5 90 7 1
-28.75 0.5 7.5 90 7 -1
1.19 1.05 0.76 0.47 0.28 0.23 0.28 0.46 0.76 1.04 1.22 1.21 1.11 1.12 1.13 1.10 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.10 1.11 1.13 1.13 1.12 1.24 1.24 1.06 0.77 0.47 0.28 0.22 0.27 0.47 0.76 1.07 1.17 1.20 1.24 1.20 1.16 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.12 1.15 1.18 1.19 1.17 1.21 1.08 0.76 0.47 0.27 0.22 0.28 0.47 0.77 1.06 1.21 1.16 1.14 1.15 1.14 1.11 1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.20 1.24 1.22 1.17 1.06 0.76 0.44 0.23 0.11 0.05 0.02 0.01 0.01 0.00 0.00 0.00
1.39 1.34 0.94 0.59 0.36 0.30 0.36 0.58 0.96 1.32 1.47 1.38 1.18 1.17 1.15 1.12 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.12 1.13 1.15 1.17 1.19 1.37 1.47 1.34 0.96 0.59 0.36 0.28 0.35 0.59 0.96 1.33 1.38 1.33 1.27 1.22 1.17 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.13 1.16 1.20 1.25 1.31 1.44 1.31 0.95 0.59 0.35 0.28 0.36 0.59 0.94 1.37 1.39 1.29 1.20 1.18 1.16 1.12 1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.21 1.25 1.28 1.32 1.28 0.95 0.550 .29 0.14 0.06 0.03 0.01 0.01 0.00 0.00 0.00
1.27 1.19 0.87 0.57 0.35 0.30 0.35 0.55 0.87 1.14 1.33 1.33 1.22 1.19 1.17 1.14 1.11 1.08 1.07 1.06 1.06 1.07 1.08 1.12 1.15 1.17 1.19 1.21 1.28 1.31 1.17 0.87 0.56 0.35 0.28 0.35 0.55 0.87 1.15 1.29 1.29 1.29 1.24 1.19 1.13 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.13 1.18 1.22 1.25 1.28 1.30 1.17 0.86 0.56 0.34 0.28 0.35 0.54 0.86 1.18 1.30 1.31 1.23 1.20 1.18 1.14 1.11 1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.11 1.16 1.22 1.26 1.25 1.23 1.14 0.85 0.520 .28 0.14 0.07 0.03 0.01 0.01 0.00 0.00 0.00
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 -20 -15 -10 -5 0
3ft24ft29 ft29ft
View IES files
Sure-Lites
Page 38 of 46
SELDWA Emergency Light
TD505137EN page 3
June 23, 2020 8:25 AM
53 ft
0.6
0.4
3 ft
0.10.20.20.30.50.71.01.31.62.02.22.22.32.53.76.39.09.48.17.06.66.36.26.16.26.36.67.08.19.49.16.33.72.52.32.32.22.01.61.31.00.70.50.40.30.20.10.10.10.10.10.10.10.10.20.30.40.50.71.01.31.62.02.22.22.32.53.76.39.09.48.17.06.66.36.26.06.26.36.67.08.19.49.06.33.72.52.22.22.22.01.61.31.00.70.50.30.20.20.1
0.10.10.20.30.40.60.81.11.41.71.91.91.92.02.74.66.56.45.55.35.04.74.84.64.84.75.05.35.56.46.54.62.72.01.91.91.91.71.41.10.80.60.40.30.20.20.10.10.10.10.10.10.10.10.20.20.30.40.60.81.11.41.71.91.91.92.02.74.66.46.45.55.35.04.74.84.64.84.75.05.35.56.46.44.62.72.01.91.91.91.71.41.10.80.60.30.20.10.1
0.10.10.10.20.30.40.60.81.01.11.21.21.21.11.21.52.12.21.81.71.82.02.22.32.22.01.81.71.82.22.11.61.21.11.21.21.21.11.00.80.60.50.30.20.20.10.10.10.10.10.10.10.10.10.10.20.20.30.50.60.81.01.11.21.21.21.11.21.52.12.21.81.71.82.02.22.32.22.01.81.71.82.22.11.51.21.11.21.21.21.11.00.80.40.30.20.10.10.1
X Y Z Orient Tilt
23.5 0.5 7.5 90 0
129.5 0.5 7.5 90 0
-29.5 0.5 7.5 90 0
76.5 0.5 7.5 90 0
182.5 0.5 7.5 90 0
X Y Z Orient Tilt
23.5 0.5 7.5 90 0
129.5 0.5 7.5 90 0
-29.5 0.5 7.5 90 0
76.5 0.5 7.5 90 0
182.5 0.5 7.5 90 0
50 ft
SELDWA50SD
Technical Data
AccuLED Optics™
• Precision engineered optics display sharp cutoffs
and oval light pattern for a clear path of egress per
UL924 standards
• Efficient optical design increases spacing distance
between units
• Provides evenly diffused light pattern throughout the
egress path for both 1 footcandle average and 0.1
footcandle minimum
• Lens swivel feature provides forward-throw of
egress lighting
Mechanical Housing
• Die-cast aluminum construction
• Mounting hole pattern is universal to junction box
requirements and suitable for wall mount or conduit
mount
• Housing color available in bronze, black, white or
silver
EZ Hang Mounting Feature
• Hands-free feature allows installer to hang the
emergency light face from the back plate to easily
and efficiently make power connections
Brownout Circuit
• Monitors the flow of AC current
• Activates the emergency lighting system when a
predetermined reduction/dip of AC power occurs
(a dip in voltage will cause most ballasted products
to extinguish, causing loss of normal lighting even
though a total power failure has not occurred)
Low Voltage Disconnect
• Low-voltage circuitry disconnects the lighting load
when battery’s terminal voltage falls
• Disconnect remains in effect until normal utility
power is restored, preventing deep battery discharge
Self-Diagnostics
• Automatically performs all tests required by UL924
and NFPA 101
• Indicates the status of the emergency light at all
times using the LED indicator
• 90-minute battery power (emergency mode)
simulation test occurs randomly once every 12
months
• 30-second battery power simulation test occurs
every 30 days
• Solid-State microprocessor-based system has the
ability to accurately detect and warn of system
failures
• Incorporates all of the standard electronic features
• Systematically calibrates itself in the field, reducing
installation labor and eliminating manual calibration
errors
Battery
• Rechargeable battery offers high discharge rates
and stable performance over a wide range of
temperatures
• Resealable vent automatically controls cell pressure,
assuring safety and reliability
• Best suited for harsh ambient temperatures due to
the electrolyte is not active in the electrochemical
process
• Mullion-mount option enabled with the
SELDWAMMKIT accessory
Warranty
• Five-year warranty against defects in material and
workmanship
• Lead cadmium battery has a seven-year prorated
warranty
Photometry
Sure-Lites
Page 39 of 46
SELDWA Emergency Light
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions
subject to change without notice.
TD505137EN page 4
June 23, 2020 8:25 AM
Self
Diagnostic
Self Diagnostic Testing Operations
The Sure-Lites Self-Diagnostics is continuously monitoring your emergency fixture, and will signal any failure through the 3
color indicator LED.
Initial Operation:
When the unit is first powered up, it will go into a 24 hour fast charge, indicated by the indicator LED pulsing green. Once the unit has fully charged, it will
perform a self calibration, after which the LED will change to steady green, indicating the unit is fully charged and float charging the battery to maintain
readiness.
Automatic Testing:
The unit will perform a battery capacity, lamp/LED, and charge circuit test every 30 days for 30 seconds. During this time, the indicator LED will change to a steady yellow. It
will perform a full battery capacity (90 minute) test once per year. During this time, the indicator LED will change to a blinking yellow.
Manual Testing:
• 10 Second “Installation ” test – Press and release the test button once during fast charge (blinking green) to initiate a 10 second quick test. The sign will switch to
emergency mode for 10 seconds allowing the installer to verify proper installation of the unit, and the LED indicator will turn solid yellow
•
30 Second
Test - Press and release the test button once during float charge (steady green). The indicator LED will turn steady yellow to indicate the unit is performing a 30
second test of the batteries and lamps/LEDs
•
90 Minute
Test - Press and release the test button a second time during a 30 second test (steady yellow) to change to a 90 minute test. During this test, the LED indicator
will change to blinking yellow, and the circuit will perform a full battery capacity, charge circuit, and LED test
•
Canceling
Test – Press and release the test button during the 90 minute test (flashing yellow) to return the fixture to its original state (fast charge or float charge)
Laser Test:
The SD versions are equipped with a Laser Test function, that allows the unit to be manually tested without the need to physically press the test button. Shining a laser pointer
in the hole marked “LASER TEST” on the bottom of the unit has the same effect as a press and release of the test button.
Clearing Failure Codes:
• A batter y failure (LED two blink red) can be cleared by replacing the battery. Disconnecting the battery and AC power, or performing a full 90 minute discharge, will reset the
error code, however, it will return if the battery is faulty
•
Char
ge Circuit (LED three blink red) and lamp/LED failure (LED four blink red) will clear when the unit successfully passes a manual or automatic 30 second test
Indicators:
• LED Off - No power t o unit, emergency mode.
•
LED Steady Gr
een - Unit is fully charged and is float charging the battery to maintain readiness.
•
LED Gr
een Pulse - Unit is in a 24 hour fast charge of the battery.
•
LED
Two Blink Red - Battery has failed a capacity test, or the battery is disconnected. See “Clearing Failure Codes” above.
•
LED
Three Blink Red - Battery charge circuit has failed. See “Clearing Failure Codes” above.
•
LED F
our Blink Red - Lamps have burned out, or on an EXIT/Combo, 50% or more of the LEDs have failed. See “Clearing Failure Codes” above.
•
LED Steady Y
ellow - 30 second test or 10 second quick test (Fast Charge only).
•
LED Blinking Y
ellow - 90 minute test.
Maintenance:
None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local
codes.
OFF - EMERGENCY
MODE / POWER OFF
2 BLINK RED -
BATTERY FAILURE
STEADY GREEN -
FULL / FLOAT
CHARGE
STEADY BLINK YELLOW
- 90 MINUTE TEST
3 BLINK RED - CHARGE
CIRCUIT FAILURE
4 BLINK RED - LAMP/
LED FAILURE
STEADY YELLOW -
QUICK TEST
STEADY BLINK
GREEN - FAST
CHARGE
SURE-LITES
SELF
DIAGNOSTICS
Sure-Lites
Page 40 of 46
Specifications and
dimensions subject to
change without notice.
Cooper Lighting Solutions
1121 Highway 7 4 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
LUMEN MAINTENANCE
POWER AND LUMENS BY FIXTURE MODEL
CURRENT DRAW
XTOR CROSSTOUR LED
100
01 02 03 04 05 06 07 08 09 01 00
75
80
85
90
95
Hours (Thousands)
Lumen Maintenance (Percent)
50°C
40°C
25°C
TD514013EN
December 14, 2021 5:27 PM
page 2
Voltage
Model Series
XTOR1B XTOR2B XTOR3B XTOR4B
120V 0.103A 0.15A 0.22A 0.34A
208V 0.060A 0.09A 0.13A 0.17A
240V 0.053A 0.08A 0.11A 0.17A
277V 0.048A 0.07A 0.10A 0.15A
347V 0.039A 0.06A 0.082A 0.12A
Ambient
Temperature
TM-21 Lumen
Maintenance
(72,000 Hours)
Theoretical
L70
(Hours)
XTOR1B Model
25°C > 90% 255,000
40°C > 89% 234,000
50°C > 88% 215,000
XTOR2B Model
25°C > 89% 240,000
40°C > 88% 212,000
50°C > 87% 196,000
XTOR3B Model
25°C > 89% 240,000
40°C > 88% 212,000
50°C > 87% 196,000
XTOR4B Model
25°C > 89% 222,000
40°C > 87% 198,000
50°C > 87% 184,000
LED Information XTOR1B XTOR1B-W XTOR1B-Y XTOR2B XTOR2B-W XTOR2B-Y XTOR3B XTOR3B-W XTOR3B-Y XTOR4B XTOR4B-W XTOR4B-Y
Delivered Lumens
(Wall Mount) 1,418 1,396 1,327 2,135 2,103 1,997 2,751 2,710 2,575 4,269 4,205 3,995
Delivered Lumens
(With Flood
Accessory Kit) 1
1,005 990 940 1,495 1,472 1,399 2,099 2,068 1,965 3,168 3,121 2,965
B.U.G. Rating 2 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G0 B2-U0-G0 B2-U0-G0
CCT (Kelvin) 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000
CRI (Color
Rendering Index) 70 70 70 70 70 70 70 70 70 70 70 70
Power
Consumption
(Watts)
12W 12W 12W 18W 18W 18W 26W 26W 26W 38W 38W 38W
NOTES: 1 Includes shield and visor. 2 B.U.G. Rating does not apply to floodlighting.
Page 41 of 46
Specifications and
dimensions subject to
change without notice.
Cooper Lighting Solutions
1121 Highway 7 4 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
XTOR CROSSTOUR LED
STOCK ORDERING INFORMATION
ORDERING INFORMATION
TD514013EN
December 14, 2021 5:27 PM
page 3
Sample Number : XTOR2B-W-WT-PC1
Series 1 LED Kelvin Color Housing Color Options (Add as Suffix) Accessories (Order Separately) 8
XTOR1B=Small Door, 12W
XTOR2B =Small Door, 18W
XTOR3B =Small Door, 26W
XTOR4B =Medium Door,
38W
BAA-XTOR1B=Small Door,
12W, Buy American Act
Compliant 7
TAA-XTOR1B =Small Door, 12W
Trade Agreements
Act Compliant 7
BAA-XTOR2B =Small Door,
18W, Buy American Act
Compliant 7
TAA-XTOR2B =Small Door, 18W,
Trade Agreements
Act Compliant 7
BAA-XTOR3B =Small Door,
26W, Buy American Act
Compliant 7
TAA-XTOR3B =Small Door, 26W,
Trade Agreements
Act Compliant 7
BAA-XTOR4B = Medium Door,
38W, Buy American Act
Compliant 7
TAA-XTOR4B = Medium Door,
38W, Trade Agreements
Act Compliant 7
[Blank] = Bright White
(Standard), 5000K
W=Neutral White, 4000K
Y=Warm White, 3000K
[Blank] = Carbon Bronze
(Standard)
WT=Summit White
BK=Black
BZ=Bronze
AP=Grey
GM=Graphite Metallic
DP=Dark Platinum
PC1=Photocontrol 120V 2
PC2=Photocontrol 208-277V 2, 3
347V=347V 4
HA=50ºC High Ambient 4
WG/XTOR =Wire Guard 5
XTORFLD-KNC =Knuckle Floodlight Kit 6
XTORFLD-TRN =Trunnion Floodlight Kit 6
XTORFLD-KNC-WT =Knuckle Floodlight Kit, Summit
White 6
XTORFLD-TRN-WT =Trunnion Floodlight Kit, Summit
White 6
EWP/XTOR = Escutcheon Wall Plate, Carbon Bronze
EWP/XTOR-WT = Escutcheon Wall Plate, Summit White
NOTES:
1. DesignLights Consortium ® Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details.
2. Photocontrols are factory installed.
3. Order PC2 for 347V models.
4. Thru-branch wiring not available with HA option or with 347V. XTOR3B not available with HA and 347V or 120V combination.
5. Wire guard for wall/surface mount. Not for use with floodlight kit accessory.
6. Floodlight kit accessory supplied with knuckle (KNC) or trunnion (TRN) base, small and large top visors and small and large impact shields.
7. Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to
DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements.
8. Accessories sold separately will be separately analyzed under domestic preference requirements. Consult factory for further information.
Domestic Preferences 1 12W Series 18W Series 26W Series 38W Series
[Blank]=Standard XTOR1B=12W, 5000K, Carbon Bronze XTOR2B =18W, 5000K, Carbon
Bronze
XTOR3B =26W, 5000K, Carbon
Bronze
XTOR4B =38W, 5000K, Carbon Bronze
BAA=Buy American
Act
XTOR1B-WT =12W, 5000K, Summit White XTOR2B-W =18W, 4000K, Car-
bon Bronze
XTOR3B-W =26W, 4000K,
Carbon Bronze
XTOR4B-W =38W, 4000K, Carbon Bronze
TAA= Trade
Agreements Act
XTOR1B-PC1 =12W, 5000K, 120V PC,
Carbon Bronze
XTOR2B-WT =18W, 5000K, Sum -
mit White
XTOR3B-WT =26W, 5000K,
Summit White
XTOR4B-WT =38W, 5000K, Summit White
XTOR1B-W =12W, 4000K, Carbon Bronze XTOR2B-PC1 = 18W, 5000K,
120V PC, Carbon
Bronze
XTOR3B-PC1 = 26W, 5000K,
120V PC, Carbon
Bronze
XTOR4B-PC1 = 38W, 5000K, 120V PC,
Carbon Bronze
XTOR2B-W-PC1 = 18W, 4000K,
120V PC, Car-
bon Bronze
XTOR3B-W-PC1 =26W, 4000K,
120V PC,Carbon
Bronze
XTOR4B-W-PC1 = 38W, 4000K, 120V PC,
Carbon Bronze
XTOR2B-347V = 18W, 5000K,
Carbon Bronze,
347V
XTOR3B-347V =26W, 5000K,
Carbon Bronze,
347V
XTOR4B-347V =38W, 5000K, Carbon
Bronze, 347V
XTOR2B-WT-PC1 =18W, 5000K,
120V PC,Summit
White
XTOR3B-PC2 =26W, 5000K,
208-277V PC,
Carbon Bronze
NOTES:
1. Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to
DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements.
Page 42 of 46
Page 43 of 46
1
DDEESSIIGGNN TTEEAAMM//DDRRBB CCOOMMMMEENNTT SSHHEEEETT
TThhee ccoommmmeennttss bbeellooww aarree ssttaaffff rreeccoommmmeennddaattiioonnss ttoo tthhee DDeessiiggnn RReevviieeww BBooaarrdd ((DDRRBB))
aanndd ddoo NNOOTT ccoonnssttiittuuttee DDRRBB aapppprroovvaall oorr ddeenniiaall..
PROJECT NAME: 150 William Hilton Parkway DRB-000605-2025
Old Schoolhouse Park toilet Facility
DATE: 7/08/2025 CATEGORY: Conceptual
RECOMMENDATION: Approval Approval with Conditions Denial
APPLICATION MATERIAL
DRB REQUIREMENTS Complies
Yes
No
Not Applicable Comments or Conditions
Demolition Plan if needed
Existing Conditions match As-Built
Dimensioned Details and of Sections
Detail Illustrating Connection to Existing Structure
New Building Details Match Existing Building Details
ARCHITECTURAL DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Structure is designed to be appropriate to the
neighborhood
Promotes pedestrian scale and circulation
Design is unobtrusive and set into the natural
environment
Utilizes natural materials and colors
Avoids distinctive vernacular styles
Design is appropriate for its use
All facades shall have equal design characteristics
Page 44 of 46
2
Avoids monotonous planes or unrelieved repetition
Has a strong roof form with enough variety to provide
visual interest
Overhangs are sufficient for the façade height.
Forms and details are sufficient to reduce the mass of the
structure
Human scale is achieved by the use of proper proportions
and architectural elements
Utilizes a variety of materials, textures and colors
Incorporates wood or wood simulating materials
Windows are in proportion to the facade
Details are clean, simple and appropriate while avoiding
excessive ornamentation
Utilities and equipment are concealed from view
Decorative lighting is limited and low wattage and adds
to the visual character
Lighting specs and details are provided in this
submittal.
Accessory elements are designed to coordinate with the
primary structure
LANDSCAPE DESIGN
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
Treats the Landscape as a major element of the project Please provide landscaping around the toilet facility.
Provides Landscaping of a scope and size that is in
proportion to the scale of the development
Provide landscaping that is scaled and proportioned to
the building.
Landscape is designed so that it may be maintained in
its natural shape and size
Preserves a variety of existing native trees and shrubs
Provides for a harmonious setting for the site’s
structures, parking areas or other construction
Location of existing trees and new trees provides
street buffers, mitigation for parking lots, and an
architectural complement that visually mitigates
between parking lots and building(s)
Shrubs are selected to complement the natural setting,
provide visual interest and screen less-desirable
elements of the project
A variety of species is selected for texture and color Provide a variety of species for enhanced texture and
color.
Provides overall order and continuity of the Provide a Planting Plan.
Page 45 of 46
3
Landscape plan
Native plants or plants that have historically been
prevalent on the Island are utilized
Please utilize native plant life.
A variety of sizes is selected to create a “layered”
appearance for visual interest and a sense of depth
Provide a layered appearance as much as possible for
visual interest.
The location of existing mature trees is taken into
account in placement of shrubs so as not to damage
tree roots
Proper spacing and location for plants to reach their
mature size and natural shape while avoiding
excessive or unnatural pruning
Proposed groundcovers are evergreen species with
low maintenance needs
Large, grassed lawn areas encompassing a major
portion of the site are avoided
The adjacent development is taken into account in
determining the most appropriate buffer so as not to
depart too dramatically from the neighborhood
Ornamentals and Annuals are limited to entrances and
other focal points
NATURAL RESOURCE PROTECTION
DESIGN GUIDE/LMO CRITERIA Complies
Yes
No
Not Applicable Comments or Conditions
An effort has been made to preserve existing trees and
under story plants
Supplemental and replacement trees meet LMO
requirements for size, species and number
Wetlands if present are avoided and the required
buffers are maintained
Sand dunes if present are not disturbed
COMMENTS & CONDITIONS
Staff recommends approval of the Sign System submittal with the following conditions:
1. Provide a materials board with the color samples.
2. Provide a Planting Plan for the landscape around the toilet facility.
3. Any additional information as required by the Board.
Page 46 of 46
Source: Town of Hilton Head Island website. First collected Nov 3, 2026.