RecordWell Data

Board of Zoning Appeals Meeting — Agenda Packet

Town of Bluffton · Beaufort County · Board of Zoning Appeals · meeting of Sep 1, 2026 · Agenda packets

Open the original document More from Town of Bluffton

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Board of Zoning Appeals Meeting Tuesday, September 01, 2026 at 6:00 PM Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20 Bridge Street, Bluffton, SC AGENDA I. CALL TO ORDER II. ROLL CALL III. NOTICE REGARDING ADJOURNMENT The Board of Zoning Appeals will not hear new items after 9:30 p.m. unless authorized by a majority vote of the Board Members present. Items which have not been heard before 9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined by the Board Members. IV. ADOPTION OF MINUTES A. July 7, 2026 Minutes V. PUBLIC COMMENT VI. OLD BUSINESS VII. NEW BUSINESS A. 36 Tabby Shell Road, Lot 19 Building Setback (Variance): The Applicant, Steven G. Stowers of Architecture 101 on behalf of property owners John Gering and Ashley Gering, requests a variance from Unified Development Ordinance (UDO) Section 5.15.5.C to allow a four-foot-six- inch encroachment into the required five-foot setback, resulting in a six-inch setback for the carriage house. The property consists of approximately 0.10 acres identified by tax map number R610 039 000 1199 0000 within the Tabby Shell Development in the Neighborhood General-Historic District (NG-HD). (ZONE-08-26-020413) (Staff - Dan Frazier) VIII. DISCUSSION IX. ADJOURNMENT NEXT MEETING DATE: Tuesday, October 6, 2026 Page 1 Town of Bluffton, SC Board of Zoning Appeals Meeting Agenda September 01, 2026 “FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the Freedom of Information Act and the Town of Bluffton policies.” In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA compatible. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the scheduled event. Executive Session – The public body may vote to go into executive session for any item identified for action on the agenda. *Please note that each member of the public may speak at one public comment session and a form must be filled out and given to the Town Clerk. To submit a public comment online, please click here: https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60 Public comment is limited to 3 minutes per speaker. Page 2 Board of Zoning Appeals Meeting Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20 Bridge Street, Bluffton, SC July 07, 2026 I. CALL TO ORDER Staff called the meeting to order at 6pm. II. ROLL CALL PRESENT Board Member Amy Aldana Board Member Donald Emerick Board Member Gerry Workman Board Member Josh Tiller ABSENT Vice Chairman Tim Dolnik III. ELECTION OF OFFICERS A. Election of Board of Zoning Appeals Chair Board Member Emerick nominated Tim Dolnik as Chair. Seconded by Board Member Aldana. Voting Yea: Board Member Aldana, Board Member Emerick, Board Member Workman, Board Member Tiller All were in favor and the motion passed. B. Election of Board of Zoning Appeals Vice-Chair Board Member Aldana nominated Don Emerick as Vice Chair. Voting Yea: Board Member Aldana, Board Member Emerick, Board Member Workman, Board Member Tiller All were in favor and the motion passed. IV. ADOPTION OF MINUTES A. June 2, 2026 Minutes Board Member Workman made a motion to adopt the minutes as written. Seconded by Board Member Aldana. Voting Yea: Board Member Aldana, Vice Chair Emerick, Board Member Workman Voting Abstaining: Board Member Tiller The motion passed 3-0, with 1 abstention. V. PUBLIC COMMENT VI. OLD BUSINESS Page 3 Section IV. Item #A. Town of Bluffton, SC Board of Zoning Appeals Meeting Minutes July 07, 2026 VII. NEW BUSINESS A. Pinellas Park Building C Parking (Variance): The Applicant, Jennifer Tosky of Pinellas Park LLC, requests a variance from the Buckwalter Planned Unit Development (PUD) Development Agreement, Development Standards Ordinance 90/3 as modified, Section 5.2.1.1. to allow a reduction in the required minimum off-street parking for proposed restaurant use. The property is identified by tax map number R610 022 000 1143 0000 located within the Buckwalter PUD. (ZONE-06-26-020315) (Staff - Angie Castrillon) Staff presented. The applicant was present. There was discussion regarding the parking in the development as a whole. The board members had questions about how the parking requirements were determined by the Buckwalter Planned Unit Development (PUD). Richardson LaBruce, attorney to the Board, provided an overview of the variance process, including the criteria required to establish a hardship. Further discussion addressed the options available to the applicant for obtaining approval of additional parking. The applicant also provided information on the uses of other buildings within the development and how those uses may impact parking demand for the subject building. Board Member Tiller made a motion to approve the variance with the following condition: 1. The applicant shall submit a development plan amendment to incorporate eight (8) additional parking spaces. Seconded by Board Member Aldana. Voting Yea: Board Member Aldana, Board Member Tiller Voting Nay: Vice Chair Emerick, Board Member Workman This motion failed due to a lack of majority vote. Discussion continued. Richardson LaBruce explained the Board’s options in this instance, noting that the item could be further discussed or tabled until a meeting at which the full Board is present. Board Member Workman made a motion to table the item. Seconded by Vice Chair Emerick. Voting Yea: Board Member Workman Voting Nay: Board Member Aldana, Vice Chair Emerick, Board Member Tiller The motion failed 1-3. Discussion continued. There was discussion regarding the applicable UDO requirements if the property were not located within a PUD. The Board reviewed the seven review criteria to determine whether each criterion had been satisfied. Board Member Aldana made a motion to approve the application as submitted. Seconded by Board Member Tiller. Voting Yea: Board Member Aldana, Board Member Workman, Board Member Tiller Voting Nay: Vice Chair Emerick The motion passed 3-1. Page 4 Section IV. Item #A. Town of Bluffton, SC Board of Zoning Appeals Meeting Minutes July 07, 2026 VIII. DISCUSSION IX. ADJOURNMENT Board Member Workman made a motion to adjourn. Seconded by Board Member Aldana. Voting Yea: Board Member Aldana, Vice Chair Emerick, Board Member Workman, Board Member Tiller All were in favor and the motion passed. The meeting adjourned at 7:38pm. Page 5 Section IV. Item #A. BOARD OF ZONING APPEALS STAFF REPORT DEPARTMENT OF GROWTH MANAGEMENT MEETING DATE: September 1, 2026 PROJECT: 36 Tabby Shell Road, Lot 19 Building Setback Variance Request APPLICANT: Steven G. Stowers, Architecture 101 PROJECT NUMBER: ZONE-08-26-020413 PROJECT MANAGER: Dan Frazier Planning Manager Department of Growth Management REQUEST: The Applicant, Steven G. Stowers of Architecture 101 on behalf of property owners, John Gering and Ashley Gering, requests a variance from Unified Development Ordinance (UDO) Section 5.15.5.C to allow a 4-foot 6-inch encroachment into the required 5-foot rear yard setback for a Carriage House (accessory structure) (Attachment 1). INTRODUCTION: The subject property consists of approximately 0.10 acres identified by tax map number R610 039 000 1199 0000 within the Tabby Roads Development in the Old Town Bluffton Historic District, Neighborhood General- Historic District (NG-HD) (Attachment 2). The Board of Zoning Appeals (BZA) hearing was advertised in The Island Packet on August 16, 2026 (Attachment 3). The property was posted, and adjacent property owners were notified by certified mail in accordance with Unified Development Ordinance (UDO) public notice requirements. BACKGROUND: The subject property is located within the Neighborhood General- Historic District (NG-HD) and is subject to the standards set forth in the Unified Development Order (UDO) Section 5.15, Old Town Bluffton Historic District. Under Section 5.15.5.C, Carriage Houses must be set five (5) feet back from the rear property line (Attachment 4). Per the recorded plat for Tabby Roads, setbacks for accessory structures shall meet Town regulations in effect at the time of application for approval of such structures (Attachment 5, Tabby Roads Subdivision Plat). The subject property consists of a 0.10-acre parcel located at 36 Tabby Shell Road (Lot 19) within the Tabby Roads subdivision. The parcel is currently vacant and is located at the southwest corner of the intersection of Tabby Shell Road and Burnt Church Road (Attachment 5, Lot 19 Survey). Pluff Mud Lane provides rear access to Page 6 Section VII. Item #A. September 1, 2026 Page 2 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals all Carriage Houses on Tabby Shell Road. The Applicant proposes to construct a new 2.5-story single-family residence of approximately 4,918 SF, with a 1,618 SF footprint, and a two-story Carriage House of approximately 988 SF, with a 494 SF footprint, as submitted in the Certificate of Appropriateness-Historic District (COFA- HD) on August 3, 2026 (Attachment 5, Site Plan). The lot is irregular in shape compared to neighboring lots within the Tabby Roads development, with an acute trapezoidal geometry that is 91 feet deep on the long end and only 56 feet deep at the Burnt Church Road end. The Tabby Roads Architectural Review Board (ARB) reviewed and approved a variance for this encroachment on July 2, 2026 (Attachment 6). BOARD OF ZONING APPEALS ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.D.2 of the Unified Development Ordinance, the Board of Zoning Appeals has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. REVIEW CRITERIA & ANALYSIS: In assessing an application for a Variance, the Board of Zoning Appeals is required to consider the criteria set forth in Section 3.7.3 of the UDO. The seven criteria are provided below followed by a Staff Finding for each criterion. As expressed in Section 3.7.3.B.1., a variance may be granted as applicable, and the application must comply with the following: Page 7 Section VII. Item #A. September 1, 2026 Page 3 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals Unnecessary Hardship. A Variance from a dimensional or design standard may be granted by the Board of Zoning Appeals in an individual case of unnecessary hardship upon a finding that all the following standards are met: 1. Section 3.7.3.B.1.a. There are extraordinary and exceptional conditions pertaining to the particular piece of property; The Applicant states, “Lot 19 of the Tabby Roads Development is substandard by most if not all criteria and is set aside from its adjoining lots in size, orientation, and arrangement. The acute quadrangle of the parcel unnaturally constricts the siting of a traditional vernacular Bluffton residence, forcing the house design to conform to the angled lot lines and pushing the Carriage House beyond the 5’ rear setback. Finding. The subject property contains approximately 4,516 SF (0.10 acres) and is irregularly shaped, with a depth ranging from approximately 56 feet to 91 feet. 91 ft. 56 ft. Page 8 Section VII. Item #A. September 1, 2026 Page 4 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals Finding. Lot 19 is irregular in shape compared to other lots within the Tabby Roads development. 2. Section 3.7.3.B.1.b. These conditions do not generally apply to other property in the vicinity, particularly those in the same zoning district; The Applicant states, “As shown in our attached exhibit, Lot 19 is the only lot within Tabby Roads that contains this awkward geometry. Lot 10 suffered a substantial intrusion into their lot to accommodate the community open space easement and was granted a variance to accommodate their carriage house.” Finding. The submitted subdivision plat depicts Lot 19 with an irregular trapezoidal configuration, while the other lots along Pluff Mudd Lane are generally rectangular in configuration. Finding. This condition does not generally apply to other properties in the vicinity. 3. Section 3.7.3.B.1.c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property in a manner consistent with others in the zoning district; The Applicant states, “All other lots along Pluff Mudd Lane have an accessory structure with the exception of Lot 17, and they have received approval of a plan to build a carriage house on their lot.” Finding. The Tabby Roads subdivision was originally platted in 2004, prior to the establishment of the Unified Development Ordinance (UDO) in 2011. 93 ft. 93 ft. Page 9 Section VII. Item #A. September 1, 2026 Page 5 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals Finding. The recorded plat references that setbacks for accessory structures shall meet Town regulations in effect at the time of application for approval of such structures (Attachment 5, Tabby Roads Subdivision Plat). Finding. While the lot is buildable, the development was created prior to UDO regulations, including Section 5.7.4 Lot Layout and Design and 5.15.5.F Old Town Bluffton Historic District, General Standards, which regulate lot layout, design, and building orientation (Attachment 4 and 7). 4. Section 3.7.3.B.1.d. The need for the Variance is not a result of the Applicant’s own actions; The Applicant states, “The applicant did not have any role in creating the substandard lot and has worked tirelessly over the past four years to site a house that meets the strict requirements of the UDO and Tabby Roads ARC. It is a very hard lot to build on. The applicant first communicated with Tabby Roads’ ARC in late 2021. From that time, they have been in constant communication with the ARC to determine an appropriate way to develop this unique lot; with their first preliminary submission being in January 2023. There have been several renditions of the plans submitted to the ARC to comply with the requirements, as well as several revisions to satisfy their comments and requests. At this time, the design has received full approval of the Tabby Roads ARC, including the variance. The applicant has encountered several impactful setbacks on this project, including a proposed road widening of Burnt Church Road that delayed the project further by threatening to acquire their property through immanent domain.” Finding. Lot 19 was established in its current configuration and dimensions as part of the original Tabby Roads subdivision plat, recorded in 2004, prior to the Applicant’s proposed development of the property. Finding. The Tabby Roads Development Plan does not require a Carriage House on every lot. 5. Section 3.7.3.B.1.e. The authorization of a Variance does not substantially conflict with the Comprehensive Plan and the purposes of this Ordinance; The Applicant states, “This variance does not conflict with the Comprehensive Plan and the purpose of the ordinance as it merely facilitates a carriage house that is smaller than neighboring carriage houses and will not encroach on any neighbors. Pluff Mudd Lane dead ends at this lot and is primarily occupied overhead by Santee Cooper transmission lines.” Page 10 Section VII. Item #A. September 1, 2026 Page 6 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals Finding . The subject property is located within the Neighborhood General–Historic District (NG-HD), has a Future Land Use designation of Town Center, and is located within the Old Town Master Plan area. The proposed development consists of a single-family residence and accessory structure. A Carriage House is a permitted accessory building type within the NG-HD District. Finding. The proposed residential use and accessory Carriage House are permitted within the applicable zoning district. 6. Section 3.7.3.B.1.f. The authorization of this Variance will not result in a substantial detriment to adjacent property or the public good, and the character of the District will not be harmed by the granting of the Variance; and The Applicant states, “Authorizing this variance will not result in a substantial detriment to the adjacent property or the public good, as no neighbors are encroached upon and the subject property is at the end of the lane. No views or vistas are blocked by the encroachment, and the encroachment is not visible from Tabby Shell Road.” Finding . The proposed Carriage House is located along the Pluff Mudd Lane side of Lot 19, where the lane terminates at the rear of the property. Finding. On July 2, 2026, the Tabby Roads Architectural Review Board approved a variance from the applicable private covenants for the proposed development. Finding. The requested encroachment is oriented toward the Pluff Mudd Lane right-of-way rather than the adjacent property. 7. Section 3.7.3.B.1.g. The reason for the Variance is more than simply for convenience or to allow the property to be utilized more profitably. The Applicant states, “The reason for the variance is to help the landowners better utilize the awkward lot shape. The lots along Tabby Shell Road are consistently 93-feet plus deep. Lot 19 is 91-feet deep on the long end and only 56-feet deep at Burnt Church Road. This short end forces the development to take advantage of the deeper portion of the lot as much as possible to accommodate the principal structure which forces the carriage house to encroach on the rear setback. Finding . While Lot 19 has an irregular shape, it is still buildable without the requested Variance. Finding. The Tabby Roads Development Plan does not require a Carriage House on every lot. Page 11 Section VII. Item #A. September 1, 2026 Page 7 of 7 36 Tabby Shell Road, Lot 19 - Variance Board of Zoning Appeals CONCLUSION: In considering the variance request, Board members should base their decision on the evidence presented in the record and evaluate the application against each of the seven variance criteria established in UDO Section 3.7.3.B.1. The Board's decision should be supported by Findings of Fact, identifying the facts and evidence relied upon, and Conclusions of Law, explaining how those findings satisfy or fail to satisfy each applicable criterion. All seven criteria must be met in order for the Board to approve the variance request. ATTACHMENTS: 1. Application and Narrative 2. Vicinity Map 3. Public Advertisement 4. Unified Development Ordinance (UDO) Section 5.15, Old Town Bluffton Historic District 5. Exhibits provided by Applicant 6. Tabby Roads HARB Variance Approval 7. Unified Development Ordinance (UDO) Section 5.7.4, Lot Layout and Design Page 12 Section VII. Item #A. ATTACHMENT 1 Page 13 Section VII. Item #A. Architecture 101 2 3 A Market, Suite 1 Beaufort, South Carolina 29906 www.A101.Design Steve@A101.Design (P) 843.790.4101 ZBA VARIANCE NARRATIVE A ugust 4, 2026 Bluffton Zonin g Board of App eals Town of Bluffton 20 Bridge Street Bluffton, SC 29910 Project: Gering Residence, 36 Tabby Shell Road Thank you for considering our proposed variance request for the new single - family residence with a carriage house at Lot 19, 36 Tabby Shell Road at Tabby Roads . NARRATIVE This project proposes a single - family residence situated at the intersection of 36 Tabby Shell Road and Burnt Church Road . The lot is irr egular when compared to it ’s neighboring lots within the Tabby Roads development and the odd shape has forced the proposed residence to conform to the trapezoidal shape . It has also resulted in the carriage house being located closer to Pluff Road Lane than the 5 - foot accessory structure setback required by the current Bluffton Unified Development Ordinance permits. The intent of this variance request is to permit an encroachment into the required 5 - foot setback to allow for the reasonable development of the property. The variance would accommodate these site constraints and will allow the residence to be appropriatel y sited without adversely affecting neighboring properties, public safety, or the overall intent and purpose of the zoning ordinance. Lot 19 is the last lot on Pluff Road L ane , which dead ends at the rea r of the lot and shares the right - of - way with a large Santee Cooper overhead e lec trical t ransmission line that feed s the electrical s ubstation across Burnt Church Road from Lo t 19. Along Pluff Ro ad Lane there is no consistent façade line created by the carriage houses at the rear of the residences. The carriage house s along Pluff Road Lane s tep back and forth in a manner that creates a lively rear streetscape and which will make the proposed en croachment feel very n atural an d not at all out of pla ce . This is recognized in the encroachment v ariance already approved by the Tabby Roads Archi tec tural Review C ommittee and included for your re ference . ATTACHMENT 1 Page 14 Section VII. Item #A. Architecture 101 2 3 A Market, Suite 1 Beaufort, South Carolina 29906 www.A101.Design Steve@A101.Design (P) 843.790.4101 The enc roach ment is al so not visible from Tabby Shell Road and does n ot meaningfully change the appearance of the pro pose d residence from Bur nt Church Road. The only adjacent property , Lot 18 is unaffected by the encroachment and the vie w from the adjacent scho ol is heavily wooded and not visible from their prop erty. JUSTIFICATION Section 3. 7.3 of the Bluffton Unified Development Ordinance list s the following Application Review Cri teria that the variance must co mply with : a. T here are extraordinary and exceptional conditions pertaining to the particular piece of property; • Lot 19 of the Tabby Roads De velopment is substandard b y most if not a ll criteria and is set aside from its adjoining lots in si z e, orient ation, and arrangement. The acute quadrangle o f the parcel un naturally constricts the siting of a traditional ver nac ular Blu ffton residen ce , forcing the house de sign to conf orm to the angled lot lines and pushing the carriage house beyond the 5 ’ rear setback. b. These conditions do not generally apply to other property in the vicinity, particularly those in the same zoning district; • As shown in our attached e x hibit , Lot 19 is the only lot with in Tabby Roads that contains this awkward geo metr y . Lot 10 su ffere d a substantial intrusion into their lot to accommodate the co mmunity open space easement and was granted a variance to acc ommodate their carriage h ouse. c. Because of these conditions, the application of the Ordinance to the particular piece of property would effectively prohibit or unreasonably restrict the utilization of the property in a manner consistent with others in the zoning district; • All other lots a long Pluff Mudd Lane have an accessory structure with the exception of Lot 17 , and they have received approval of a plan to build a carriage house on their lot. ATTACHMENT 1 Page 15 Section VII. Item #A. Architecture 101 2 3 A Market, Suite 1 Beaufort, South Carolina 29906 www.A101.Design Steve@A101.Design (P) 843.790.4101 d. The need for the Variance is not the result of the Applicant’s own actions; • The applica nt did not have any role i n creating the s ubstandard lot and has worked tirelessly over the past four years to si te a house that meets the strict requirements of the UDO and Tabby Roads AR C . I t is a very hard lot to build on . • The applicant first communicated with Tabby Roads’ ARC in late 2021. From that time, they have been in constant communication with the ARC to determine an app ropriate way to develop this unique lot ; with their first preliminary submission being in January 2023. There have been several renditions of the plans submitted to the ARC to comply with the requirements, as well as several revisions to satisfy their comments and requests. At this time, the design has received full approval of the Tabby Roads ARC , including the variance . • The applicant ha s encountered several impactful setbacks o n this project , including a proposed road widening of Burnt Church Road that delayed the pro ject further by threatening to acquire their property through immanent domain. e. The authorization of a Variance does not substantially conflict with the Comprehensive Plan and the purposes of this Ordinance; • Th is varia nce does not conflict with the Comprehensive Plan and the purpose of the ord inance as it merely facilitates a carri age house that is smaller than neighbo ring carr iage houses and will not encroach on any n eighbors . Pluff Mudd Lane dead ends at this lot and is primarily occupied overhead by Santee Co oper transmission lines . f. The authorization of a Variance will not result in a substantial detriment to adjacent property or the public good, and the character of the District will not be harmed by the granting of the Variance; and • Authorizing this variance will not result in a substantial detriment to the adjacent propert y or the public good , as no neighbors a re encroached upon and the subject property is at the end of the lane. No views or vistas are blocked by the encroachment, and the encroachment is not visible from T abby Shell Road . ATTACHMENT 1 Page 16 Section VII. Item #A. Architecture 101 2 3 A Market, Suite 1 Beaufort, South Carolina 29906 www.A101.Design Steve@A101.Design (P) 843.790.4101 g. The reason for the Variance is more than simply for convenience or to allow the property to be utilized more profitably. • The reason for the variance is to help the landowners better utilize the a wkward lot shape . The lo ts along Tabby Shell Road are consist ently 93 - fe et plus deep . Lot 19 is 91 - feet deep on the long end and only 56 - feet de ep at Bur nt Chu rch Road. This short end forces the development to take advantage of the deeper portion of the lot as much as possible to accommodate the principal struc ture which forces t he carriage house to encroach on the rear setback. PLUFF MUD LANE CARRIAGE HOUSE AT 34 TABBY SHELL ROAD (ADJACENT) ATTACHMENT 1 Page 17 Section VII. Item #A. Architecture 101 2 3 A Market, Suite 1 Beaufort, South Carolina 29906 www.A101.Design Steve@A101.Design (P) 843.790.4101 EX ISTING DEAD END AT PLUFF MUD LANE RENDERING OF CARRIAGE HOUSE FROM DEAD END OF PLU FF ROAD LANE Sincerely, Steven G. Stowers, AIA, LEED AP ATTACHMENT 1 Page 18 Section VII. Item #A. VICINITY MAP 36 TABBY SHELL ROAD SETBACK VARIANCE ATTACHMENT 2 Page 19 Section VII. Item #A. The Island Packet/Beaufort Gazette Publication Name:The Island Packet/Beaufort Gazette Publication URL:www.islandpacket.com Publication City and State:Hilton Head Island, SC Publication County:Beaufort Notice Popular Keyword Category: Notice Keywords: Notice Authentication Number:2026082012501926402731125420450 Notice URL: Back Notice Publish Date: Sunday, August 16, 2026 Notice Content Town of Bluffton Public Hearing NOTICE IS HEREBY GIVEN that the Town of Bluffton Board of Zoning Appeals (BZA) will hold a Public Hearing at 6:00PM, on Tuesday, September 1, 2026, at the Theodore D. Washington Municipal Building, 20 Bridge Street, Bluffton, SC for the following: ZONE-08-26-020413 - The Applicant, Steven G. Stowers of Architecture 101 on behalf of property owners John Gering and Ashley Gering, requests a variance from Unified Development Ordinance (UDO) Section 5.15.5.C to allow a four-foot-six-inch encroachment into the required five-foot setback, resulting in a six-inch setback. The property consists of approximately 0.10 acres identified by tax map number R610 039 000 1199 0000 within the Tabby Shell Development in the Neighborhood General-Historic District (NG-HD). Documents related to the above are available for public inspection and copying in the Town of Bluffton Department of Growth Management, located at 20 Bridge Street, during business hours. Persons with comments or questions should contact the Town of Bluffton Growth Management Department at (843) 706-4500. Persons requiring special services to attend the meeting should call to make arrangements. Public Comments may be submitted electronically via the Town's website at (https://bit.ly/3wg7A08). Comments will be accepted up to 2 hours prior to the scheduled meeting start time. The meeting will be open to the public. IPL0365132 Aug 16 2026 Back Page 20 Section VII. Item #A. 5.15.5 General Standards The existing or proposed building type shall determine the applicable lot standards. Except as otherwise provided by this Section, the maximum building footprint and building size for an Additional Building Type shall not exceed the largest building footprint and building size permitted for other building types permitted within the same zoning district. Within the Riverfront Edge-Historic District, the UDO Administrator may approve a building footprint up to 5,500 square feet, provided that the footprint is characteristic of a building type permitted in the district and its permitted building size range. Building types shall only be permitted as listed in the applicable District. The maximum allowed density is based on the dimensional characteristics established for each building type in combination with other site characteristics that may limit the amount of land able to accommodate density. These other site characteristics include, but are not limited to, lot con fi guration, right-of-way, easements, protected natural resources, open space, topography, and parking. A. Neighborhood Core Historic District (NC-HD) The red lines indicate the locations of required shopfront buildings (Main Street Building, Commercial Cottage, or Live-Work Sideyard). In addition to shopfront buildings, civic structures are allowed within these areas. NC-HD Regulating Plan NC-HD Precedent Imagery Neighborhood Core Building Type Requirements: Front Build- to Zone Lot Width Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Main Street Building 10'-20' 50’-100’ 70% - 90% 25’ 5’ 2-3 80% Commercial Cottage 10'-15' 50’-75’ 40% - 70% 25’ 8’ 1-1.5 80% Live-Work Sideyard 10'-15' 50’-65’ 50% - 75% 25’ 5’ 2-2.5 80% Duplex 10'-15' 55’-70’ N/A 25’ 5’ 2-3 75%Triplex 10'-15' 70’-100’ Mansion Apartment House 10'-25' 60’-80’ N/A 25’ 5’ 2-2.5 70% Civic Building 10'-25' N/A N/A N/A 5’ 2.5 80% ATTACHMENT 4 Page 21 Section VII. Item #A. Neighborhood Core Building Type Requirements: Front Build- to Zone Lot Width Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Carriage House See Sec. 5.15.8.F. for placement and other requirements 5’ 5’ 1-2 Additional Building Types As approved by the UDO Administrator or Board/ Commission with approval authority in accordance with Article 2 of this Ordinance, additional building types may be allowed in the Neighborhood Core-HD zoning district. Building types not speci fi cally listed shall be regulated by the following general requirements: 10'-25' 50’-100’ to be determined by UDO Admin. 25’ 5’ 2 - 3 80% (Ord. 2024-02, April 9, 2024; Ord. 2026-01, January 13, 2026) E ff ective on: 1/13/2026 B. Neighborhood Center Historic District (NCE-HD) The red lines indicate the locations of required shopfront buildings (Main Street Building, Commercial Cottage, or Live-Work Sideyard). In addition to store-front buildings, civic structures are allowed within these areas. NCE-HD Regulating Plan NCE-HD Precedent Imagery ATTACHMENT 4 Page 22 Section VII. Item #A. Neighborhood Center-HD Building Type Requirements: Front Build- to Zone Lot Width Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Main Street Building 10’-25’ 50’-80’ 75% - 90% 25’ 8’ 2-2.5 80% Commercial Cottage 10'-20' 50’-60’ 50% - 70% 25’ 8’ 1-1.5 80% Live-Work Sideyard 5'-10' 50’-60’ 40% - 75% 25’ 8’ 1.5-2.5 80% Duplex 10'-15' 55’-70’ N/A 25’ 8’ 1.5-2.5 75%Triplex 10'-15' 70’-100’ Mansion Apartment House 10'-25' 60’-80’ N/A 25’ 10’ 2-2.5 70% Carriage House See Sec. 5.15.8.F. for placement and other requirements. 5’ 5’ 1-2 65% Cottage 10'-15' 50’-60’ N/A 25’ 8’ 1-1.5 65% Medium House 5'-15' 50'-60' N/A 25' 8' 1-2 65% Village House 10'-15' 50’-60’ N/A 25’ 8’ 2-2.5 65% Sideyard House 10'-15' 50’-65’ N/A 25’ 8’ 2-2.5 65% Vernacular House 10’-20’ 60’-80’ N/A 25’ 10’ 1.5 65% Civic Building 10'-25' N/A N/A N/A 8’ 2 80% Additional Building Types As approved by the UDO Administrator or Board/ Commission with approval authority in accordance with Article 2 of this Ordinance, additional building types may be allowed in the Neighborhood Center- HD zoning district. Building types not speci fi cally listed shall be regulated by the following general requirements: 10’-25’ 50’- 100’ to be determined by UDO Admin. 25’ 8’ 1-2.5 80% (Ord. 2024-02, April 9, 2024; Ord. 2026-01, January 13, 2026) E ff ective on: 1/13/2026 C. Neighborhood General Historic District (NG-HD) Within the NG-HD district, building form and scale shall be primarily residential to maintain the predominantly residential character component of this district. The UDO Administrator may waive the mandatory residential component for properties with frontage on SC Highway 46 and Bruin Road; buildings on these properties may be constructed with retail shopfronts, awnings, marquees, colonnades, or arcades in accordance with this UDO but must be residential in form and scale. ATTACHMENT 4 Page 23 Section VII. Item #A. C. Neighborhood General Historic District (NG-HD) NG-HD Regulating Plan NG-HD Precedent Imagery Neighborhood General Building Type Requirements: Front Build-to Zone Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Carriage House See Sec. 5.15.8.F. for placement and other requirements. 5’ 5’ 1-2 Live-Work Sideyard 10’-20’ 50’-100’ N/A 25’ 10’ 1-2.5 60% Commercial Cottage 10’-20 50’-100’ N/A 25’ 10’ 1-1.5 60% Bungalow Court 10’-20’ (for foremost bungalow) 60’-100’ N/A 25’ 15’ 1-1.5 65% Cottage 10’-20’ 50’-60’ N/A 25’ 10’ 1-1.5 60% Medium House 10'-20' 50'-60' N/A 25' 10' 1-2 60% Village House 10’-20’ 50’-65’ N/A 30’ 15’ 2-2.5 60% Sideyard House 10’-15’ 50’-65’ N/A 30’ 5’ 2 60% Vernacular House 10’-20’ 60’-100’ N/A 30’ 15’ 1.5 60% Center Hall House 15’-25’ 70’-100’ N/A 30’ 15’ 2-2.5 60% ATTACHMENT 4 Page 24 Section VII. Item #A. Neighborhood General Building Type Requirements: Front Build-to Zone Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Civic Building 10’-35’ N/A N/A N/A 10’ 2 80% Additional Building Types As approved by the UDO Administrator or Board/ Commission with approval authority in accordance with Article 2 of this Ordinance, additional building types may be allowed in the Neighborhood General-HD zoning district. Building types not speci fi cally listed shall be regulated by the following general requirements: 10’-20’ 50’-100’ N/A 25’ 10’ 1 - 2.5 70% (Ord. 2024-02, April 9, 2024; Ord. 2026-01, January 13, 2026) E ff ective on: 1/13/2026 D. Neighborhood Conservation Historic District (NCV-HD) NCV-HD Regulating Plan NCV-HD Precedent Imagery ATTACHMENT 4 Page 25 Section VII. Item #A. Neighborhood Conservation Building Type Requirements Front Build-to Zone Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Carriage House See Sec. 5.15.8.F for placement and other requirements. 5’ 5’ 1-2 Cottage 10’-20’ 50’-60’ N/A 30’ 10’ 1-1.5 60% Medium House 10'-20' 50'-70' N/A 30' 10' 1-2 60% Village House 10’-20’ 50’-70’ N/A 30’ 10’ 2-2.5 60% Vernacular House 15’-25’ 60’-100’ N/A 30’ 10’ 1.5 60% Center Hall House 20’-35’ 80’-100’ N/A 30’ 15’ 2-2.5 60% Civic Building 15’-40’ N/A N/A N/A 10’ 1.5 80% Additional Building Types As approved by the UDO Administrator or Board/ Commission with approval authority in accordance with Article 2 of this Ordinance, additional building types may be allowed in the Neighborhood Conservation -HD zoning district. Building types not speci fi cally listed shall be regulated by the following general requirements: 10’-35’ 50’-100’ N/A 30’ 10’ 1 - 2.5 70% (Ord. 2024-02, April 9, 2024; Ord. 2026-01, January 13, 2026) E ff ective on: 1/13/2026 E. Riverfront Edge Historic District (RV-HD) In the Riverfront Edge HD district Zone, the river shall be the focus of each lot abutting it and therefore acts as the “front” of the lot. RV-HD Regulating Plan RV-HD Precedent Imagery ATTACHMENT 4 Page 26 Section VII. Item #A. Riverfront Edge Building Type Requirements: Riverfront Build- to Zone Lot Width Frontage Requirement Setback (from rear property line) Side Setback (from side property lines) Height (in stories) Maximum Lot Coverage Carriage House See Sec. 5.15.8.F. for placement and other requirements. 5’ 10’ 1-2 Cottage ≥150’ Perpendicular to, and in a horizontal plane from, the OCRM line ≥60’ N/A 20’ 10’ 1-1.5 50% Vernacular House ≥75’ N/A 20’ 20’ 1.5 50% Center Hall House ≥75’ N/A 20’ 20’ 2-2.5 50% River House ≥75’ N/A 20’ 20’ 1.5-2 50% Civic Building 15’-50’ N/A N/A N/A 15’ 1.5 80% Additional Building Types As approved by the UDO Administrator or Board/Commission with approval authority in accordance with Article 2 of this Ordinance, additional building types may be allowed in the Riverfront Edge-HD zoning district. Building types not speci fi cally listed shall be regulated by the following general requirements: ≥150’ Perpendicular to, and in a horizontal plane from, the OCRM line ≥60’ N/A 20’ 20’ 1 - 2.5 50% (Ord. 2024-02, April 9, 2024; Ord. 2026-01, January 13, 2026) E ff ective on: 1/13/2026 F. General Standards 1. Building Heights a. Building heights and widths shall be visually similar to those in the neighboring vicinity. b. Building heights are regulated by the number of stories, based on the designated Zoning Districts. c. Residential structures shall have a fi rst fi nished fl oor height raised a minimum of three (3) feet above average adjacent sidewalk grade. The fi rst fi nished fl oor height can be elevated as much as fi ve (5) feet above average adjacent sidewalk grade without counting the undercroft as a story. d. Each story above the fi rst story in commercial and residential buildings shall be a minimum of eight (8) feet and a maximum of twelve (12) feet high from fl oor to ceiling. Floors more than twelve (12) feet, as measured from fl oor to ceiling, will count as additional fl oors. e. A space under a sloping roof that has the line of intersection of the roof and the exterior wall supporting the roof not more than 3 feet above the fl oor level, and in which space the possible fl oor area with head room of 5 feet or more occupies between 30 and 70 percent of the total fl oor area of the story directly beneath. If the possible fl oor area with head room of 5 feet or more occupies more than 70 percent of the total fl oor area of the story directly beneath, then that space shall be considered a full story. f. Appurtenances may extend above the building height limits, but may not exceed 50’ above the adjacent grade level. ATTACHMENT 4 Page 27 Section VII. Item #A. Do not clump everything equally under one enormous roof. Many [building forms] with a confusing assembly of gables show the guest at fi rst glance neither the entry nor the principal rooms of the house. All buildings should pass the First Glance Test. Source: Traditional Construction Patterns, p.62-63 Do mass a house so that it passes the First Glance Test. Massing of a house should clearly show two things at fi rst glance: the location of the main body of the house and the location of the entry for people, which ought to be more important and more noble than the car entry. Do not use complicated forms. Too many gables, dormers, and roof breaks are not appropriate and can unnecessarily increase costs. Source: Traditional Construction Patterns, p. 60-61 Do keep massing simple. Composing a house of one or a few simple boxes can save costs for more appropriate architectural elements like proper porch detailing, back porches, garden walls, frontage fences, pergolas, and a number of other items. 2. Building Form, Massing, and Scale a. Building mass shall consist of a simple composition of basic building forms that follow a clear hierarchy. b. Roo fl ines shall be simple, utilizing gables, hips, and sheds, or combinations of these basic forms. Roofs shall correspond to the major massing of the building; roof forms that overwhelm the mass of the primary building form and complicated roo fl ines are to be avoided. ATTACHMENT 4 Page 28 Section VII. Item #A. c. Incorporate elements that give the building perceptible scale. Large buildings in particular shall be designed to reduce their perceived height and mass by dividing the building into smaller scale components. d. Long unarticulated masses shall be avoided. As an example, simple o ff sets of the primary façade can articulate the overall building massing and help reduce the perception of mass and scale. 3. Architectural Elements and Projections a. Buildings shall incorporate interruptions and variety into the wall plane to create interest and variety in the streetscape while still maintaining a consistent architectural style and connection to its surroundings. Examples include but are not limited to o ff sets, recessed entrances, arcades, awnings and canopies, bay windows, roof overhangs, expression lines, shadow lines, porches and balconies. 4. Building Composition (Proportion, Alignment, Rhythm, and Spacing) a. Overall building proportions and Individual building features shall have a proportional relationship with one another. For example, features such as porches, chimneys, cornices, windows and doors must be proportional to other features of the building as well as the overall building form. b. Additions, connective wings, and outbuildings shall be secondary to the primary building form. c. Building elements and the spaces between them shall be organized into a logical sequential manner. d. Horizontal rhythm should be established by the organization of the building facade into horizontal bands which provides human scale and proportion to the facade. e. Vertical rhythms should be established in the façade through alignment of windows, openings, pilasters, and columns. 5. Building Orientation a. The front principal façade of all buildings must be built parallel to the street that it faces. b. When a shopfront building abuts more than one street (i.e. occurs at a corner), it shall maintain at least 50% street frontage along its secondary street, in addition to the requirement for its primary street frontage. 6. Exceptions from Build-to Lines. Exceptions to Build-to Lines may be granted by the UDO Administrator where existing signi fi cant natural features are present, to preserve protected trees and to preserve the integrity of neighboring historic resources. Exceptions may also be granted to accommodate outdoor design features such as dining areas, open-air markets and public art features. 7. Drive-thrus. Drive-thrus shall not be permitted in the Old Town Bluffton Historic District. ATTACHMENT 4 Page 29 Section VII. Item #A. 8. Franchise Design. The quality of Bluffton’s unique environment should not be eroded by inappropriate franchise designs and signage. It has been demonstrated in design conscious communities around the world that franchises can maintain their identity while working in a distinct context. The UDO Administrator and the HPC will evaluate franchise design proposals based on conformance with this Section. 9. Service Yards. If a service yard is provided, service items, such as waste receptacles, air-conditioning equipment, pool equipment, above ground propane tanks, irrigation equipment, utilities and other service-related items shall be located in rear or side yards not facing a street, away from all public vantages, and screened from view. The HPC may approve alternate locations and screening for utilities if they are unable to be located within the service yard. If a service yard is not provided, service items, at listed above, shall be located and screened as required by Sec. 5.15.6.F. a. Materials used in building service yards shall be visibly compatible with the materials used in the primary structure and accessory structure(s). b. The service yard may be enclosed by louvers, lattice, vertical board or board-on-board panels, or such other styles typical of earlier styling. c. The height of the service yard enclosure shall be su ffi cient to screen equipment from public vantages; however, may not exceed six (6’) feet in height. d. Window air-conditioning units shall not be placed on the primary façade of the primary structure or of any accessory structure. e. Roof mounted equipment, if required, shall be low-pro fi le and located at the side or rear elevations to not be visible from the street. f. Utility meters shall be screened from public view. 10. Sheds. Sheds shall not be taller than one story, exceed 121 square feet, and no more than three (3) are permitted per lot. (Ord. 2024-02, April 9, 2024) E ff ective on: 4/9/2024 ATTACHMENT 4 Page 30 Section VII. Item #A. ATTACHMENT 5 Page 31 Section VII. Item #A. ATTACHMENT 5 Page 32 Section VII. Item #A. HY D 13 TOK 8 G 7 G 8 LOK 6 G 15 WOK 10 G 14 P 10 P 6 P 20 LOK 9 LAOK 8 P 9 P 8 LAOK 11 P 12 P 11 P 10 P 13 P 16 P 13 P 8 P 10 LOK 15 P 13 P 10 WOK 6 P 10 G 20 P 10 LAOK 6 MAG 9 P 15 P 21.9 22.3 22.4 23.2 23.7 23.7 23.4 23.7 23.8 24.4 24.7 23.9 23.6 23.4 23.4 23.6 22.9 22.1 21.8 22.2 22.3 22.4 23.6 23.5 23.4 23.3 22.5 22.8 23.0 21.9 22.0 22.1 23.2 24.2 24.7 23.6 22.2 22.5 23.5 24.5 23.9 23.9 23.9 24.4 24.8 2 2.0' 23.0' 23.0' 23.0'23.0' 24.0' 24.0' 24.0' 24.0' 24.0' 0.10 acres 4,516 sq. ft. 2 6' POWER LINE EASEMENT 6 ' B.S.L. 10.5' B.S.L. 5' B.S.L. 7.5' B .S.L. B URNT CHURCH RD. S-7-163 66' R/W #36 TABBY SHELL RD. LOT 19 PLUFF MUDD LANE LOT 18 TABBY SHELL ROAD 50' R/W 0.3' X IN CONC. CONC. X IN 3"X3" CMF 1/2" IPF REBAR REBAR IPS 1/2" N07° 02'17"E 91.91' S52°44'22"E 80.38' N84°15'00"W 45.42' C1 C2 GRAVEL EDGE OF PAVEMENT CONC. CENTER LINE OF ROAD CONC. S/W EDGE OF PAVEMENT CENTER LINE OF ROAD T ABBY SHELL RD. B URNT CHURCH RD. U TILITY EASEMENT LOT 18 23A, Market, Ste.1 - B eaufort, South Carolina - w ww.A101.Design Drawn By Checked By 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 19 20 21 22 23 A B C D E F G H J K L M N P Q R This drawing is the property of Architecture 101, L LC and may not be reproduced or copied without written permission. Reference scales as indicated on drawings. Do not scale drawings. Consult the Architect for necessary clarifications. N OT FOR CONSTRUCTION B E A U F O R T - S A V A N N A H 8 /4/2026 2:17:51 PM E X100 EXISTING SITE SURVEY SGS JAT 8/4/2026 2024.49 1/4" = 1'-0"A1 SITE SURVEY G ERING RESIDENCE B LUFFTON, SC ( LOT #19) 36 TABBY SHELL RD REV# DESCRIPTION DATE +23.5 ATTACHMENT 5 Page 33 Section VII. Item #A. 2 2.0' 2 6' POWER LINE EASEMENT UP DN UP 4,324 SF - SITE AREA 0 40' 60' 80'20' Scale: 1/20" = 1'-0" N T ABBY SHELL RD. B URNT CHURCH RD. PROPERTY LINE 7 '- 0" BUILDING SETBACK P ROPERTY LINE LOT 18 EXISTING RESIDENCE 5 ' - 0" 10' - 6" 7 ' - 6" B UILDING SETBACK 2 4' - 6" EXISTING ELECTRICALPULL BOX 7 ' - 8" MECHANICAL YARD 2 ' - 0" 4' - 8" 2' - 0" 2 ' - 0" 6' - 8" 9 " 9 ' - 7" EXISTING PULL BOX WILL BE RELOCATED TO ALTERNATE LOCATION WITHIN EASEMENT BY UTILITY. THE NEW LOCATION WILL NOT INTERFERE WITH GARAGE ACCESS. 15 P 20 LOK 15 WOK 8 LOK 9 P A CCESSORY SETBACK 5' - 0" 6" 4' - 6" 2 4' - 9" 4'-6" x 24'-9" AREA OF INTRUSION INTO 5' -0" REAR ACCESSORY STRUCTURE SETBACK (INCLUDING 12" ROOF LINE OVERHANG) PROPOSED 2.5-STORY RESIDENCE PROPOSED 2-STORY CARRIAGE HOUSE LOT 18 EXISTING GARAGE L IVIN G FENCE L IVING FENCE H EDGE L IVIN G FENCE L IVIN G FENCE L IVIN G FENCE L IVIN G FENCE PRO PERTY LINE P LUFF MUD LANE MASONRY CHIMNEY 60' CANOPY 60' CANOPY 50' CANOPY 30' CANOPY 30' CANOPY MGCW 30' CANOPY LIM 20' CANOPY LIM 20' CANOPY 3' - 4" 1' - 8" 23A, Market, Ste.1 - B eaufort, South Carolina - w ww.A101.Design Drawn By Checked By 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 19 20 21 22 23 A B C D E F G H J K L M N P Q R This drawing is the property of Architecture 101, L LC and may not be reproduced or copied without written permission. Reference scales as indicated on drawings. Do not scale drawings. Consult the Architect for necessary clarifications. N OT FOR CONSTRUCTION B E A U F O R T - S A V A N N A H 8 /25/2026 11:04:31 AM A 100 S ITE PLAN SGS JAT 8/25/2026 2024.49 1/4" = 1'-0"A1 SITE PLAN G ERING RESIDENCE B LUFFTON, SC ( LOT #19) 36 TABBY SHELL RD REV# DESCRIPTION DATE +23.0 +23.5 +26.2 +26.0 AVG. SIDEWALK ELEV. TREE CANOPY COVERAGE TOTAL LOT SIZE: 4,324 GSF LESS BUILDING FOOTPRINT (INCL. PORCHES): -2,776 GSF TOTAL SITE REMAINING: 1,548 NSF TOTAL SITE COVERED BY MATURE CANOPY: 1,176 NSF LOT COVERAGE PERCENTAGE REQUIRED: 75% LOT COVERAGE PERCENTAGE PROVIDED: 76% ATTACHMENT 5 Page 34 Section VII. Item #A. ATTACHMENT 5 Page 35 Section VII. Item #A. Architectural Review Board Tabby Roads Bluffton, SC July 2, 2026 Variance APPROVAL John and Ashley Gering Lot 19, 36 Tabby Shell Road, Bluffton, South Carolina 29910 Dear Mr. and Mrs. Gering, This letter shall serve as approval for a variance by the Tabby Roads Architectural Review Board as outlined in Tabby Roads CC&Rs Article IV 4.5 for the following: • Applicant is permitted to encroach on the rear setback (as shown in the Site Development Plan Rev4 Aug 2015) for Lot 19 with an ancillary structure provided said structure remains within the property boundaries and is fully approved by the Tabby Roads ARB. • Applicant is permitted a heated square footage footprint up to but not to exceed 40% of the square footage of Lot 19. This deviation from the Site Development Plan (Rev4 Aug 2015) and the Covenants as shown in the current plans (COFA 10-25-019985) is granted as a variance as outlined in the Tabby Roads CC&Rs Article XX 20.3. The heated square footage footprint is calculated based on the first floor heated square footage of all structures built upon the lot. Heated square footage above an unconditioned garage space does not count towards this requirement. I am sending a copy of this variance to the Town of Bluffton for their file. I trust this variance will be satisfactory for your needs. If you have any questions concerning any item contained herein, please contact us at your convenience. Thank you for your understanding. Best regards, James Ogden, AIA, NCARB Chairman of the Tabby Roads ARB ATTACHMENT 6 Page 36 Section VII. Item #A. 5.7.4 Lot Layout and Design. The arrangement, shape, and size of proposed parcels shall comply with this Section, and with any other provisions that apply to proposed subdivisions. A. Lot design standards. 1. Buildable lots. Each proposed lot shall be determined by the review authority to be “buildable” because it contains at least one building site that can accommodate a structure in compliance with all applicable provisions of this Ordinance. 2. Islands and Strips of Land. No subdivision shall be approved which leaves unsubdivided islands, strips or parcels, or property unsuitable for subdividing, which is not either accepted by the Town of Bluffton or other appropriate entity for public use, or maintained as dedicated common area within the development. 3. Lot line orientation. Side lot lines shall be generally at right angles to the street on straight streets and shall be radial on curved streets. 4. Lot con fi guration. The layout of proposed lots and roadways shall be designed to use land e ffi ciently and minimize site disturbance in terms of cuts and fi lls and the removal of vegetation. 5. Access. Every lot shall have access to a public or private roadway (access may be via a recorded cross or shared access easement). Subdivision design shall provide for safe and ready access for fi re and other emergency equipment and for routes of escape to safely and e ffi ciently handle evacuations. 6. Roadway frontage required. a. The frontage width shall be at least the minimum lot width required by the applicable Zoning District, except where a fl ag lot is approved in compliance with this Section. b. Through lots with roads along both the front and rear parcel lines shall be discouraged (an alley is not considered a roadway for the purposes of this Section.) Where through lots are created, a rear-yard landscaped bu ff er with a minimum width of 10 feet is required. ATTACHMENT 7 Page 37 Section VII. Item #A. c. For through lots as described herein, the UDO Administrator shall determine which frontage(s) shall be considered as the front lot line(s) for the purposes of compliance with the minimum applicable yard and setback requirements. 7. Flag lots. Flag lots may be approved only where the UDO Administrator fi rst determines that unusual depth or other characteristic of a lot to be subdivided prevents one or more proposed lots from having a frontage width equal to the minimum lot width required by the applicable Zoning District. ATTACHMENT 7 Page 38 Section VII. Item #A.

Source: Town of Bluffton website. First collected Nov 7, 2026.