Historic Preservation Review Committee Meeting — Agenda Packet
Town of Bluffton · Beaufort County · Historic Preservation Review Committee · meeting of Jul 13, 2026 · Agenda packets
Open the original document More from Town of Bluffton
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Historic Preservation Review Committee Meeting
Monday, July 13, 2026 at 4:00 PM
Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers,
20 Bridge Street, Bluffton, SC
AGENDA
I. CALL TO ORDER
II. ROLL CALL
III. PUBLIC COMMENT
IV. OLD BUSINESS
V. NEW BUSINESS
1. 33 Guerrard Avenue: A request by Patrick Mason (Patrick Mason Custom Homes), on behalf
of Webbdean Dev, LLC (Owner), for a review of a Certificate of Appropriateness - HD (Concept
Plan) to construct a new 2-story Medium House type of approximately 2,300 SF and a 2-story
detached Carriage House of approximately 814 SF, to be located at 33 Guerrard Avenue in Old
Town Bluffton Historic District and zoned Neighborhood General - HD zoning District. (COFA-
04-26-020206) (Staff – Charlotte Moore)
VI. DISCUSSION
VII. ADJOURNMENT
NEXT MEETING DATE: Monday, July 20, 2026
Page 1
Town of Bluffton, SC Historic Preservation Review Committee Meeting Agenda July 13, 2026
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance
with the Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the
Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of
disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA
compatible. Auditory accommodations are available. Any person requiring further accommodation
should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or
adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Executive Session – The public body may vote to go into executive session for any item identified for
action on the agenda.
*Please note that each member of the public may speak at one public comment session and a form must
be filled out and given to the Town Clerk. To submit a public comment online, please click here:
https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60
Public comment is limited to 3 minutes per speaker.
Page 2
PLAN REVIEW COMMENTS FOR COFA-04-26-020206
Town of Bluffton
Department of Growth Management
20 Bridge Street P.O. Box 386 Bluffton, South Carolina 29910
Telephone 843-706-4522
OLD TOWN
Plan Type: Apply Date:
Plan Status: Plan Address: 33 Guerrard Avenue
BLUFFTON, SC 29910
Historic District
Hold
04/08/2026
Plan PIN #:Case Manager: R610 039 00A 0425 0000Charlotte Moore
Plan Description: A request by Patrick Mason (Patrick Mason Custom Homes), on behalf of the owner, Webb Dean Development,
LLC, for review of a proposed 2300 SF Medium House Type and a detached 814 SF Carriage House at 33
Guerrard Street (Lot 1B) in the Old Town Bluffton Historic District and zoned Neighborhood General-HD.
(STATUS 05.01.2026): Concept Plan has inconsistencies that the applicant has been requested to revise
before HPRC review. Will reschedule HPRC meeting when revised Concept Plan is received. STATUS
(07.01.2026): Concept Plan to be reviewed by HPRC on July 13, 2026.
Staff Review (HD)
Submission #: 1 Recieved: 04/08/2026 Completed:
Reviewing Dept. Complete Date StatusReviewer
Pending ReviewBeaufort Jasper Water and Sewer
Review
Matthew Michaels
Pending ReviewGrowth Management Dept Review
(HD)
Angie Castrillon
Pending ReviewHPRC Review Charlotte Moore
Denied07/10/2026HPRC Review Charlotte Moore
Comments:
07/10/2026 Page 1 of 3Page 3
Section V. Item # 1.
1. Site Improvements: Show all horizontal and vertical improvements on the site plan. At a minimum, the site plan is missing a
front walk, driveway and the service yards. It is unclear what other items the may be constructed that are not depicted on the site
plan since these principal items are missing.
2. Plan Set Order: Order the plan set in the industry standard fashion: foundation, floor plans, elevations, building sections,
detailed sections, electrical plans.
3. Driveway: Provide a driveway layout that will allow for foundation plantings along the side of the home to soften the transition
between landscape and vertical construction.
4. Brackets: The diagonal bracket member is unclear and appears too skinny on the elevations.
5. Windows: All of the windows are out of scale with each other. Some window lites have exaggerated tall, skinny proportions,
while others are very squat and square. They must be of a similar proportion (ratio) to give the overall design a sense of
proportion. The left and rear elevations of the house rely too heavily on transom windows. Revisit these elevations to include
windows to break up the facade and balance with the remainder of the architecture.
6. Chimney and Fireplace: The fireplace and chimney should rest on a foundation and not “float” by cantilevering from the
house. Additionally, restudy the proportion of the bishop cap chimney with traditional applications.
7. Columns: Restudy the spacing of the front porch columns and first floor front windows to have some relationship to the main
roof centerline and windows above. For the rear porch, ensure that column spacing complies with UDO 5.15.6.H.1.a., and show
compliance with dimensions on the elevations.
8. Railing Detail: Update the railing detail to comply with 5.15.6.H.3.d: 2 ¾” minimum top rail.
9. Soffit: Hardie soffit is not an approved soffit material. Refer to carriage house wall section detail.
10. Hardie board Dimensions: 2x hardie board is not a real material even though it is called out throughout the plans. Hardie
board only comes in 1x & 5/4x thicknesses. Indicate an alternative material where 2x hardie indicated on the plans. Indicate the
width of all board as well (i.e. “2x8” not just “2x”). There are several instances of 1x as well. If a board needs to be cut to size,
indicate as necessary (i.e. “1x4 cut to 3””)
11. Foundation Vents: Vent sizing is inconsistent and vents lack alignment.
12. If all of the low pitch roofs at the porches have exposed rafters, so should the back porch.
13. The rear door says 6’-8” on the elevations and 8’-0” in the schedule, would prefer 8’-0” so it aligns with the window head.
14. Show a depiction of the main structure and carriage house together to see and compare the height difference.
15. The carriage house structure is too vertical; consider adding a bracketed roof over the garage door and man doors would
help.
16. The left and right elevations of the carriage house are too broad and unarticulated.
17. The window on the right second floor elevation of the carriage house is too small and low. Consider adding a dormer as
provided on the left side.
18. The carriage house dormer roof is too flat and should be a minimum of 4/12.
19. The carriage house attic louvers are too close to the roof as well as too short and fat.
DeniedGrowth Management Dept Review
(HD)
Charlotte Moore
Comments:
1. The plan provided appears to be a near replication of the project at 8 Wharf Street (also the same owner).
2. Lot Coverage: The NG-HD district limits the maximum lot coverage to 60%. Lot coverage includes all impervious surfaces.
While the application shows only 100 square feet of impervious surface, the site plan does not include the driveway, service areas
for the main structure and carriage house, front and rear main structure stairs, and the required walkway from the front porch to
the property line. Lot coverage includes areas that are not under roof, which may include gravel areas, such as driveways, if not
designed per stormwater requirements (UDO Sec. 5.10).
3. Consistency of Information: Some information in the project analysis sheet does not match the plan set (e.g., gutters
identified as to be installed but not shown on the elevations, shutters shown as “n/a” but will be provided on the carriage house,
siding shown as “wood” on the analysis sheet but just “siding” on the main structure and “hardie-plank” on the carriage house,
etc.). Revise for consistency.
4. Building Orientation: Per UDO Sec. 5.15.5.F.5.a., the front principal façade of all buildings must be built parallel to the street
that it faces. The building orientation is slightly askew.
5. Service Yards: Show service yards and details in compliance with UDO Sec. 5.15.5.F.9.
6. Vehicle Access: Is the garage intended to have vehicle access? The proximity of the main structure and the stairs (not show)
are likely to impede access.
7. Windows and Doors: Show all window and door operations and label windows based on the proposed window and door
schedule. The plan shows windows that do not appear on the elevation (“I” is a fixed-casement-fixed combination). Fixed windows
are not a permitted window operation per UDO Sec. 5.15.6.I.3.b.
8. Plan Resubmission: The full requirements for the Concept Plan submission have not been met, including detailed narrative,
photos, site plan, and architectural details as indicated on the COFA application. Given the lack of information and
inconsistencies, a second Concept Plan submission and HPRC meeting will be required. At the time of resubmission, provide a
plan set as one PDF to include the survey, site plan, and architectural plan set in the order indicated in the HPRC comments. The
Power Point presentation provided to the applicant on March 26 includes links to pertinent UDO sections that the designer should
reference to confirm compliance.
Approved with Conditions07/10/2026Beaufort Jasper Water and Sewer
Review
Matthew Michaels
07/10/2026 Page 2 of 3Page 4
Section V. Item # 1.
Comments:
Comments may be provided at time of Building Permit application.
Approved with Conditions06/30/2026Watershed Management Review Samantha Crotty
Comments:
1. All development that exceeds 5,000 square feet of land disturbance, as well as all re-development that results in an additional
2,000 square feet of impervious surface will be required to meet SoLoCo standards. 2. All development/redevelopment that
results in a cumulative impervious surface area of 5,000 square feet or greater must provide a grading/drainage plan at time of
stormwater permit review. 3. Additional stormwater comments may be provided at time of building permit submittal.
Approved with Conditions05/01/2026Watershed Management Review Samantha Crotty
Comments:
1. All development that exceeds 5,000 square feet of land disturbance, as well as all re-development that results in an additional
2,000 square feet of impervious surface will be required to meet SoLoCo standards.
2. All development/redevelopment that results in a cumulative impervious surface area of 5,000 square feet or greater must
provide a grading/drainage plan at time of stormwater permit review.
3. Additional stormwater comments may be provided at time of building permit submittal.
Approved06/22/2026Transportation Department
Review - HD
Megan Andrews
Comments:
No comments
Approved04/13/2026Transportation Department
Review - HD
Mark Maxwell
Comments:
No comments
Plan Review Case Notes:
07/10/2026 Page 3 of 3Page 5
Section V. Item # 1.
Source: Town of Bluffton website. First collected Nov 7, 2026.