Public Works Committee Meeting january 2023
City of Mauldin · Greenville County · meeting of Dec 30, 2022 · Notices
Open the original document More from City of Mauldin
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
PUBLIC WORKS
COMMITTEE MEETING
TUESD AY, JANUARY 3, 2023 | 6 PM
4th committee meeting
The Committee will meet in Mauldin City Hall at 5 East
Butler Road in the Council Chambers at 6 p.m.
The meeting will be available remotely through Zoom. Please visit the City’s website at
https://cityofmauldin.org/your-government/meeting-minutes-agendas/ to access the
meeting via audio and videoconferencing.
A quorum of Council will be present.
1
PUBLIC WORKS COMMITTEE MEETING
JANUARY 3, 2023, 6PM
CITY HALL - COUNCIL CHAMBERS
5 E. BUTLER ROAD
Committee Members: Jason Kraeling (Chair), Carol King, Michael Reynolds
1. Call to Order
2. Public Comment
3. Reading and Approval of Minutes
a.Public Works Committee Meeting: December
5, 2022 [Pages 3-4]
4. Reports or Communications from City Officers
a.Public Works Director Matt Fleahman Budget
Review
GLDTC Participation Agreement [Pages 5-12]
5. Unf
inished Business
There is no unfinished business.
6. New
Business
a.Park Restroom Facilities Upgrade [Pages 13-29]
7. Pub
lic Comment
8. Committee Concerns
9. Adjournment
The Honorable Jason Kraeling
The Hono
rable Jason Kraeling
The Hono
rable Jason Kraeling
Th
e Honorable Jason Kraeling
The H
onorable Jason Kraeling
The
Honorable Jason Kraeling
Th
e Honorable Jason Kraeling
Th
e Honorable Jason Kraeling
Th
e Honorable Jason Kraeling
2
PUBLIC WORKS COMMITTEE MEETING
DECEMBER 5, 2022, 6PM
CITY HALL - COUNCIL CHAMBERS
5 E. BUTLER ROAD
3rd committee meeting
Committee Members present: Jason Kraeling (Chair), Carol King, Michael Reynolds
Others present: PW Director Matthew Fleahman and City Administrator Seth Duncan
1. Call to Order- Chairman Kraeling
2. Public Comment- None
3. Reading and Approval of Minutes
a. Public Works Committee Meeting: November 7, 2022
Motion: Councilman Reynolds made a motion to accept the minutes with Councilwoman King
seconding.
Vote: The vote was unanimous (3-0).
4. Reports or Communications from City Officers
a. Public Works Director Matt Fleahman
Budget Review
Mr. Fleahman reported to committee that all of his divisions are under budget.
Revised plans for the East Butler Road project were received today. The concrete medians in front
of the fire station and sports center have been removed.
5. Unfinished Business- There is no unfinished business.
6. New Business
a. Maverick Yards Maintenance Agreement
This item is a maintenance agreement between both parties which stipulates that the City will be
primarily responsible for performing maintenance on both the parking lot and the landscaped
areas. In it, the City agrees to at a minimum reseal and restripe the parking lot every 5 years and to
repave every 20 years. The maintenance schedule for the landscaped areas has already been
implemented by the Public Works Department.
The potential cost to repave is approximately 150,000 dollars while resurfacing costs are
approximately 10,000 dollars.
Councilwoman King asked if the 5-year re-sealing is standard. Mr. Fleahman said it is a little
excessive, but we want it to look as nice as possible. Councilwoman King said if in five years it
doesn’t need to be done, we are committed to doing it. Mr. Fleahman said there is a provision in
the agreement that says it will be done as long as the funds are available.
3
Motion: Councilwoman King made a motion to send this agreement to Council with Councilman
Reynolds seconding.
Vote: The vote was unanimous (3-0).
7. Public Comment-None
8. Committee Concerns- Chairman Kraeling asked about the City Christmas decorations. Mr. Fleahman
said power is not on all the poles, so some of the decorations are not lit. A quote to repair all the
poles was $100,000. Mr. Fleahman said the decorations are very heavy and several of them fall when
it is windy outside and are damaged. Councilwoman King said the goal setting session is next month
and can be discussed then. Eventually they are going to have to be replaced.
When the East Butler Road project is done, all of the light poles will be replaced.
9. Adjournment- Chairman Kraeling adjourned the meeting at 6:44 p.m.
Respectfully Submitted,
Cindy Miller
Municipal Clerk
4
PUBLIC WORKS COMMITTEE
AGENDA ITEM
MEETING DATE: January 3, 2023
AGENDA ITEM: 2a
TO: Public Works Committee
FROM: Public Works Director, Matthew Fleahman
SUBJECT: GLDTC Participation Agreement
REQUEST
Information only, to let the Public Works Committee and City Council know that the C-Fund Collaboration
request from July 20, 2020 for the redesign of the Standing Springs Road and Ashmore Bridge road
interchange in cooperation with the County of Greenville SC will be executed aft er the Committee
Meetings.
HISTORY/BACKGROUND
The City of Mauldin worked to attain access and annexation of the former Bonnie Brae Golf Course along
Ashmore Bridge Road. The site was annexed into the City with plans to develop a 700- 800 lot housing
subdivision. During the annexation process, concerns from the public were presented regarding increased
traffic, and the alignment of Standing Springs Road onto Ashmore Bridge.
Mark III Properties the developer for the subdivision. Via their attached correspond ence, Mark III
Properties is partnered with Greenville County and the SCDOT in a multi-jurisdictional project to improve
the intersection of Ashmore Bridge Road and Standing Springs Road.
City Council approved a funding allocation of $50,000 contingent on the funding by the C -Funds
Committee during its July 2020 Council Meeting.
ANALYSIS or STAFF FINDINGS
City Staff were contacted on December 19, 2022 and informed that C -funds had been allocated to the
redesign and signaling of the intersection. A participation agreement and invoice for the $50,000 were
provided for GLTDC Project 579.
FINANCIAL IMPACT
The cost associated with modification will not exceed $50,000.00.
RECOMMENDATION
No recommendation is provided as this is for information only.
5
CITY COUNCIL
AGENDA ITEM
MEETING DATE: July 20, 2020
AGENDA ITEM: 8c
TO: City Council
FROM: Community D evelopment Director Van Broad
SUBJECT: C- Fund collaboration Re quest / v ia Greenville County
REQUEST
Council is requested to a request from Mark III Properties to assist in funding the redesign of
Standing Springs Road and Ashmore Bridge Road interchange in cooperation with the County of
Greenville SC.
HISTORY/BACKGROUND
The City of Mauldin worked to attain access and annexation of the former Bonnie Brae Golf Course
along Ashmore Bridge Road. The site was annexed into the City with plans to develop a 700-800 lot
housing subdivision. During the annexation process, concerns from the public were presented regarding
increased traffic, and the alignment of Standing Springs Road onto Ashmore Bridge.
Mark III Properties the developer for the subdivision. Via their attached correspondence, Mark III
Properties is partnered with Greenville County and the SCDOT in a multi-jurisdictional project to
improve the intersection of Ashmore Bridge Road and Standing Springs Road.
ANALYSIS / STAFF FINDINGS
While the Ashmore Bridge Rd. and Standing Springs Rd. intersection is not a Mauldin intersection, it
will be used by City residents. The proposed interchange has historically received a failing grade.
Multiple new development projects will increase stress and pressure on the interchange. As proposed by
Mark III Properties, this approach will repair the intersection in a manner to serve the existing traffic and
projected future growth.
Also, it is worth noting the SCDOT plans to install a traffic signal at the newly aligned intersection
outside of the scope of the realignment project.
6
TIMELINE/FINANCIAL
1. The project will commence upon approval of funding by the C-Funds Committee
2. The total amount being requested of the City is $50,000
3. Should Council proceed, an appropriate funding source would be fund balance.
RECOMMENDATION
It is the recommendation of staff that council approve funding of $50,000 t oward the Standing
Springs/Ashmore Bridge Re-alignment Project.
ATTACHMENTS
Letter
from Mark III Properties
Project Cost Estimate as prepared by CoTransCo
7
City of Mauldin
Mr. David Dyrhaug
5 E. Butler Road
Mauldin, SC 29662
June 8, 2020
Mr. Dyrhaug,
Mark III Properties is teaming with Greenville County and the SCDOT in a multi-jurisdictional
project to improve the intersection of Ashmore Bridge Road and Standing Springs Road. I have attached
the proposed layout. This intersection has historically received a failing grade and is being made worse
with the increased traffic in this area. It is time to fix the intersection in a manner to serve the existing
traffic and projected future growth.
The intersection is not a City of Mauldin road, however many Mauldin residents will use it every
day. With the recent annexation of the Bonnie Brae golf course property (approx. 800 homes), Camden
Cottages (68 homes) and Meadow Springs (151 homes), I estimate an increase in Mauldin’s tax base of
over $230 million from these developments over the next few years. All of these new homes will
benefit from an improved intersection at this location.
Hesha Gamble with Greenville County is planning to present this project to the CTC as soon as
possible. She feels the best chance of having it approved is to have participation from as many
stakeholders as possible. I am writing to request the City of Mauldin commit to invest $50,000 towards
this intersection improvement project. For your reference, Mark III Properties has purchased right of
way ($25,000), is donating additional right-of-way ($20,000) and is planning to contribute an additional
$100,000 for this intersection. We will also be doing extensive upgrades to Ashmore Bridge Road and
Fork Shoals Road at the Bonnie Brae property.
I understand Greenville County is working on a new / revised cost estimate, however the latest
information I have shows the cost of this project to be about $1.2 million plus the right-of-way
acquisition (which Mark III is contributing to the project). I’ve included the cost estimate. Also, note the
SCDOT plans to install a traffic signal at the newly aligned intersection outside of the scope of the
realignment project.
Feel free to contact me or Joe Waldron with Mark III Properties with any questions.
Sincerely,
Jay Beeson
8
GLDTC 566 ASHMORE BRG / STANDING SPRINGS COST ESTIMATE
ASHMORE BRIDGE RD ADDITIONAL
STANDING SPRINGS TURN LANE @
RELOCATION STANDING SPRINGS WEST
ITEM DESCRIPTION UNIT UNIT BID PRICE AMOUNT AMOUNT TOTAL QUANTITIES TOTAL $
MOBILIZATION LS $35,000.00 1 35,000.00$ 0 -$ 1.00 $35,000.00
CONSTR. STAKES LINES & GRADES LS $10,000.00 1 10,000.00$ 0.2 2,000. 00$ 1.20 $12,000.00
QUALITY CONTROL BY CONTRACTOR LS $15,000.00 1 15,000.00$ 0.2 3,000. 00$ 1.20 $18,000.00
TRAFFIC CONTROL LS $35,000.00 1 35,000.00$ 0.2 7,000. 00$ 1.20 $42,000.00
AS-BUILT CONSTRUCTION PLANS LS $3,000.00 1 3,000.00$ 0.2 600.00$ 1.20 $3,600.00
CLEARING & GRUBBING W/I ROADWAY LS $75,000.00 1 75,000.00$ 0.2 15,000. 00$ 1.20 $90,000.00
REM. & DISP. OF EXISTING CATCH BASIN EA $700.00 0 $0.00 0 $0.00 0.00 $0.00
REM. & DISP. OF EXISTING DROP INLET EA $650.00 0 $0.00 0 $0.00 0.00 $0.00
REM. & DISP. OF EXISTING PAVEMENT SY $15.00 0 $0.00 0 $0.00 0.00 $0.00
REM. & DISP. OF EXISTING ASPH. PAVEMENT SY $15.00 1500 $22,500.00 0 $0.00 1,500.00 $22,500.00
MILLING EXISTING ASPH. ROADWAY SY $1.65 0 $0.00 0 $0.00 0.00 $0.00
MILLING VARIABLE WIDTH 4" SY $7.50 0 $0.00 0 $0.00 0.00 $0.00
SITE EXCAVATION LS $200,000.00 1 $200,000.00 0.2 $40,000.00 1.20 $240,000.00
BORROW EXCAV. CY $18.00 0 $0.00 0 $0.00 0.00 $0.00
EXCAVATION FOR SHOULDER PAVING STA $0.00 0 $0.00 0 $0.00 0.00 $0.00
FINE GRADING SY $2.90 4500 $13,050.00 0 $0.00 4,500.00 $13,050.00
FLOWABLE FILL CY $95.00 0 $0.00 0 $0.00 0.00 $0.00
MAINTENANCE STONE TON $35.00 200 $7,000.00 0 $0.00 200.00 $7,000.00
HOT MIX ASPH. AGGR. BASE CR. TYPEC @ 650#/SY TON $50.00 1379 $68,950.00 550 $27,500.00 1,929.00 $96,450.00
LIQUID ASPH. BINDER PG 64-22 TON $650.00 163.92 $106,548.00 55.8 $36,270.00 219.72 $142,818.00
FULL DEPTH ASPHALT PVMT. PATCH-6" UNIFORM SY $33.00 0 $0.00 0 $0.00 0.00 $0.00
H/L ASPH. CONCRETE INTERMEDIATE CR. TYPE C @220TON $52.50 466.2 $24,475.50 190 $9,975.00 656.20 $34,450.50
H/L ASPH CONC SURF. COURSE TYPE C @ 220#/SY TON $52.50 866.8 $45,507.00 190 $9,975.00 1,056.80 $55,482.00
PERMANENT CONSTRUCTION SIGNS SF $12.50 300 $3,750.00 0 $0.00 300.00 $3,750.00
4" WH. BRK. LINE-GAPS EXC. FD PAINT LF $0.20 240 $48.00 0 $0.00 240.00 $48.00
4" WH. SLD. LINE-PVT. EDGE FD PAINT LF $0.20 5000 $1,000.00 520 $104.00 5,520.00 $1,104.00
8" WH. SOLID LINES (CRSS WLK & CHANN) FD PNT. LF $1.00 320 $320.00 0 $0.00 320.00 $320.00
24" WH. SOLID LINES F.D. PAINT LF $2.50 84 $210.00 24 $60.00 108.00 $270.00
4" YELLOW BRKN LINE GAPS EXC. FD PAINT LF $0.52 0 $0.00 0 $0.00 0.00 $0.00
4" YELLOW SLD. LINE- CENTER LINE FD PAINT LF $0.52 3500 $1,820.00 1040 $540.80 4,540.00 $2,360.80
WHITE SINGLE ARROWS - PAINT LF $55.00 8 $440.00 2 $110.00 10.00 $550.00
WHITE COMBO ARROWS - PAINT LF $55.00 1 $55.00 0 $0.00 1.00 $55.00
4" WH. BRK. LINE-GAPS EXC. THERMO 90 MIL LF $0.67 240 $160.80 0 $0.00 240.00 $160.80
4" WH. SLD. LINE-PVT. EDGE THERMO- 90 MIL LF $0.67 5000 $3,350.00 520 $348.40 5,520.00 $3,698.40
8" WH.SLD LINE (CRSS WLK & CHANN)THERMO125MIL LF $2.25 320 $720.00 0 $0.00 320.00 $720.00
24" WH. SOLID LINES THERMO- 125 MIL LF $10.00 84 $840.00 24 $240.00 108.00 $1,080.00
WHITE SINGLE ARROWS - THERMO 125 MIL EA $100.00 8 $800.00 2 $200.00 10.00 $1,000.00
WHITE COMBO. ARROWS - THERMO 125 MIL EA $150.00 1 $150.00 0 $0.00 1.00 $150.00
WH. WORD MESS."ONLY",-THER0-125MIL EA $150.00 4 $600.00 1 $150.00 5.00 $750.00
WH. WORD MESS."STOP",-THER0-125MIL EA $150.00 0 $0.00 0 $0.00 0.00 $0.00
WH. WORD MESS."AHEAD",-THER0-125MIL EA $150.00 0 $0.00 0 $0.00 0.00 $0.00
WH. WORD R/R SYMBOL,-THER0-125MIL EA $150.00 0 $0.00 0 $0.00 0.00 $0.00
4" YELLOW BRKN LINE GAPS EXC.THERMO 90 MIL LF $0.67 0 $0.00 0 $0.00 0.00 $0.00
4" YELLOW SLD. LINE- CENTER LINE THERMO-90 MIL LF $0.67 3500 $2,345.00 0 $0.00 3,500.00 $2,345.00
PERM. CLEAR PAVMT. MARKERS MONO-DIR EA $10.00 10 $100.00 0 $0.00 10.00 $100.00
PERM. YELLOW PAVMT. MARKERS MONO-DIR EA $10.00 0 $0.00 0 $0.00 0.00 $0.00
PERM. YELLOW PAVMT. MARKERS BI-DIRECTIONAL EA $10.00 50 $500.00 0 $0.00 50.00 $500.00
18" RC PIPE CUL. - CLASS III LF $55.00 64 $3,520.00 0 $0.00 64.00 $3,520.00
24" RC PIPE CUL. - CLASS III LF $65.00 64 $4,160.00 0 $0.00 64.00 $4,160.00
30" RC PIPE CUL. - CLASS III LF $60.00 0 $0.00 0 $0.00 0.00 $0.00
36" RC PIPE CUL. - CLASS III LF $75.00 0 $0.00 0 $0.00 0.00 $0.00
48" RC PIPE CUL. - CLASS III LF $85.00 0 $0.00 0 $0.00 0.00 $0.00
60" RC PIPE CUL. - CLASS III LF $100.00 48 $4,800.00 0 $0.00 48.00 $4,800.00
12" NON-REINFORCED BRICK MASONRY WALL CY $1,250.00 0 $0.00 0 $0.00 0.00 $0.00
12" REINFORCED BRICK MASONRY WALL CY $1,600.00 0 $0.00 0 $0.00 0.00 $0.00
CONCRETE STEPS CY $1,000.00 0 $0.00 0 $0.00 0.00 $0.00
ALUMINUM HANDRAIL LF $100.00 0 $0.00 0 $0.00 0.00 $0.00
CATCH BASIN TYPE 9 W/ MANHOLE EA $1,500.00 0 $0.00 0 $0.00 0.00 $0.00
CATCH BASIN TYPE16 EA $2,800.00 0 $0.00 0 $0.00 0.00 $0.00
24" x 36" DROP INLET EA $1,800.00 0 $0.00 0 $0.00 0.00 $0.00
MANHOLE EA $2,300.00 0 $0.00 0 $0.00 0.00 $0.00
CONCRETE CURB & GUTTER (1'-6") LF $12.00 0 $0.00 0 $0.00 0.00 $0.00
CONCRETE CURB & GUTTER (2'-0") LF $15.50 0 $0.00 0 $0.00 0.00 $0.00
PEDESTRIAN RAMP CONSTRUCTION SY $150.00 0 $0.00 0 $0.00 0.00 $0.00
CONC. SIDEWALK 5'- 0" (4"UNIFORM) SY $32.00 0 $0.00 0 $0.00 0.00 $0.00
DETECTABLE WARNING SURFACES SF $75.00 0 $0.00 0 $0.00 0.00 $0.00
CONCRETE DRIVEWAY(6" UNIFORM) SY $36.00 0 $0.00 0 $0.00 0.00 $0.00
AGGREGATE UNDERDRAIN (AGG. # 57) CY $25.00 0 $0.00 0 $0.00 0.00 $0.00
6" PERFORATED PIPE UNDERDRAIN LF $6.50 100 $650.00 0 $0.00 100.00 $650.00
RIP RAP (CLASS B) TON $40.00 100 $4,000.00 0 $0.00 100.00 $4,000.00
GTEX FOR EROS CNTRL UND RIPRAP(CLASS1)TYPE C SY $2.00 200 $400.00 0 $0.00 200.00 $400.00
STEEL BEAM GUARDRAIL LF $20.00 600 $12,000.00 0 $0.00 600.00 $12,000.00
END TERMINAL TYPE - T EA $3,000.00 2 $6,000.00 0 $0.00 2.00 $6,000.00
ADDITIONAL LENGTH GUARDRAIL POST LF $0.00 0 $0.00 0 $0.00 0.00 $0.00
48" CHAIN LINK FENCE LF $20.00 0 $0.00 0 $0.00 0.00 $0.00
RESET FENCE LF $15.00 0 $0.00 0 $0.00 0.00 $0.00
RESET CHAIN LINK FENCE LF $17.50 0 $0.00 0 $0.00 0.00 $0.00
PERMANENT VEGETATION MSY $1,000.00 6.333 $6,333.00 0.8 $800.00 7.133 $7,133.00
TEMPORARY VEGETATION MSY $750.00 3.667 $2,750.25 0.4 $300.00 4.07 $3,050.25
BALED STRAW BALE $0.00 0 $0.00 520 $0.00 520.00 $0.00
SILT FENCE LF $8.00 5000 $40,000.00 0 $0.00 5,000.00 $40,000.00
SILT BASIN CY $15.00 0 $0.00 0 $0.00 0.00 $0.00
DITCH CHECK TON $30.00 0 $0.00 0 $0.00 0.00 $0.00
SELF-ADHERING PAVING STRIP MEMBRANE CEO. SY $22.50 $0.00 0 $0.00 0.00 $0.00
CONCRETE FOR STRUCTURES (ROADWAY) CLASS 400 CY $1,200.00 0 $0.00 0 $0.00 0.00 $0.00
DIAMOND SOCK FILTERS (T-16 CB) LF $20.00 0 $0.00 0 $0.00 0.00 $0.00
DEMOLITION ITEM #1 LS $800.00 0 $0.00 0 $0.00 0.00 $0.00
DEMOLITION ITEM #2 LS $500.00 0 $0.00 0 $0.00 0.00 $0.00
DEMOLITION ITEM #3 LS $950.00 0 $0.00 0 $0.00 0.00 $0.00
4" WHITE PARKING LINES-PAINT LF $1.30 0 $0.00 0 $0.00 0.00 $0.00
6" YELLOW LINES- PAINT LF $0.40 0 $0.00 0 $0.00 0.00 $0.00
4" BLUE HANDICAP LINES- PAINT LF $3.00 0 $0.00 0 $0.00 0.00 $0.00
SPEED BUMPS EA $1,000.00 0 $0.00 0 $0.00 0.00 $0.00
0
PAVEMENT MARKINGS LS $2,000.00 0 $0.00 0 $0.00 0.00 $0.00
NEW ROADWAY SIGNAGE LS $2,000.00 0 $0.00 0 $0.00 0.00 $0.00
ESTIMATED CONSTRUCTION COST $762,852.55 $154,173.20 $917,025.75
UTILITIES - (POLES) EA $25,000.00 0 $0.00 0 $0.00 0.00 $0.00
10% CONTINGENCY $76,285.26 $15,417.32 $91,702.58
PE $83,913.78 $16,959.05 $100,872.83
CEI $83,913.78 $16,959.05 $100,872.83
ESTIMATED GRAND TOTAL $1,006,965.37 $203,508.62 $1,210,473.99
CUMMALITIVE TOTAL $1,210,473.99
NOTES:
1) WIDENING ALL ON ONE SIDE DUE TO UTILITY POLE RELOCATIONS NEEDED ON NORTH SIDE OF ROAD (6 POLES)
2. RIGHT-OF-WAY WILL BE REQUIRED FROM TWO PROPRTY OWNER IN ADDITION TO THE GOLF COURSE PROPERTY.
3.STANDING SPRINGS WEST TURN LANE ADDED IN ANTICIPATION OF SCDOT REQUIRMENTS.
4. SCDOT TO PROVIDE INSTALLATION OF THE SIGNAL AND ALL CROSSWALKS.
9
PARTICIPATION AGREEMENT
Greenville Legislative Delegation Transportation
Committee Project No. 579 Ashmore Bridge Rd.,
Mauldin, SC
December 19, 2022
WHEREAS, The City of Mauldin desires the Greenville Legislative Delegation Transportation Committee
(GLDTC) to assist the City of Mauldin in the design and construction of road improvements known as
GLDTC Project No. 579, being described fully on C-FUND ASSISTANCE APPLICATION,
10/14/2019, that was presented to the GLDTC at the 07/28/2022 meeting, approved 09/22/2022.
WHEREAS, Matt Fleahman is the Public Works Director for the City of Mauldin and duly authorized by
the City of Mauldin 5 E. Butler Rd, PO Box 249 Mauldin, SC 29662 (864) 289-8904 with the authority to
enter into contracts necessary for the proper discharge of its functions and duties; and
WHEREAS, the City of Mauldin is duly authorized to enter into contracts necessary for the proper
discharge of its functions and duties; and
WHEREAS, GLDTC has agreed to assist the City of Mauldin with GLDTC Project No. 579; GLDTC will
construct intersection improvements according to SCDOT Standard Specifications on Ashmore
Bridge Rd.at Standing Springs Rd.
NOW THEREFORE, in consideration of the several promises to be faithfully performed by the parties
hereto as set forth, the GLDTC and the City of Mauldin do hereby agree as follows:
Project Description:
The project is divided into three (3) parts as follows:
a) Design: Includes all preliminary engineering, location approval, right-of-way and construction
plans, and any and all other associated tasks necessary to prepare acceptable plans ;
b) Right-of-way: Includes all right-of-way acquisition services performed in accordance with
Federal and SCDOT guidelines, rules, regulations, policies and procedures relative to the
acquisition of right-of-way;
c) Construction: Includes bidding and letting of a construction contract, the actual construction
performance, construction engineering, construction inspection, sampling testing of materials,
and other associated tasks as necessary.
The term PROJECT is intended to refer to the above three Parts collectively unless otherwise indicated.
FUNDING:
GLDTC: $ 1,709,000.00 + 2/3 Overruns
Mark III Properties $ 174,142.00 + 1/3 Overruns
Hidden Lakes Preserve $ 24,403.05
Standing Springs Land Development, LLC $ 23,844.20
(Sunny Hill)
City of Mauldin $ 50,000.00
SCDOT Provide Signalization to intersection
10
The GLDTC shall:
a) Provide the GLDTC’s cost share for the PROJECT, not to exceed the $1,709,000.00;
b) Provide right-of-way acquisition cost estimates for each impacted tract of land as shown on
approved plans for the project;
c) Provide right-of-way acquisition services to secure the necessary right-of-way as shown on
approved plans for the project;
d) Provide bid advertisement, awarding of construction contract, inspection of contractor work
during execution of contract, and sampling and testing of construction procedures for
compliance with all State and local requirements;
e) Verify all contractors pay requests prior to payment.
City of Mauldin
a) Provide $50,000 at signing of participation agreement;
b) Provide right-of-way as requested by prior agreement with the SCDOT.
The GLDTC shall:
a) Enter into and execute all necessary contracts necessary to complete the approved
project;
b) Be responsible for approval of payment requests and payment of all contractor an d
s
ubcontractor pay requests;
c) Secure from the City of Mauldin funding as noted above prior to construction
bidding.
This document may not be modified or revoked without the written consent of both parties.
____
__________________________________________________________________
For: the City of Mauldin (date)
____
__________________________________________________________________
Greenville Legislative Delegation Transportation Committee Chairman (date)
11
December 19, 2022
1
579
Amount
$1,709,000.00
$50,000.00
$50,000.00
Total Due
$50,000.00
Greenville Legislative Delegation Transportation
Committee Date:
301 University Ridge, Suite 2400 Invoice #:
Greenville, SC 29601 GLDTC Project #:
In accordance with the participation agreement for GLDTC 579- Ashmore Bridge Road, the amount
due at this time is calculated below:
City of Mauldin
Attn: Matt Fleahman, Public Works Director
via email: mfleahman@mauldincitysc.com
phone: 864-467-7112
To:
Description
Total due by City of Mauldin
Project Funding
GLDTC:
City of Mauldin
Due upon receipt
Payment Terms
Invoice
Greenville Legislative Delegation
Transportation Committee Invoice
Greenville Legislative Delegation
Transportation Committee
12
PUBLIC WORKS COMMITTEE
AGENDA ITEM
M
EETING DATE: January 3, 2023
AG
ENDA ITEM: 6a
TO
: Public Works Committee
FROM: Public Works Director, Matthew Fleahman
SUBJECT: Park Restroom Facilities Upgrade
REQUEST
Authorization is requested to allocate capital funding to cover the expense of modifying the bathroom doors
City Park, Sunset Park, and Springfield Park.
HISTORY/BACKGROUND
The Public Works Department maintains bathroom structures at three City Parks. Du e to continued
vandalism and their use as a sleeping space for vagrants, the structures are required to be locked each
evening and opened each morning when the park opens. Park operating hours do not coincide with the
hours of operation for the Public Wor ks Department so the City’s Police force has been assisting in
locking/unlocking the bathrooms. Due to the irregularity in calls for service, the Police have not been able
to lock/unlock the bathrooms on a fixed schedule.
ANALYSIS or STAFF FINDINGS
The City has an electronic lock system on the bathrooms at the City Center restroom which locks/unlocks
the doors on a timer. Public Works staff reached out the City’s on- call electrical contractor and inquired
about installing this system on its other facilities. The electricians recommended Southeastern Dock &
Door as a more appropriate party to conduct the install. Southeastern has been contracted before to repair
garage doors at the PW facility and were the contractor that renovated the lobby at City Hall.
FINCANCIAL IMPACT
The cost associated with modification will not exceed $19,283.00.
RECOMMENDATION
Staff recommends the Public Works Committee and the City Council approve the allocation of 19,283.00
dollars from the Capital budget to cover renovations to the City’s restroom facilities.
13
1 1/29/22, 3:53 PM 141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction
141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction 1/4
Southeastern Dock and Door
54 Bruce Rd.
Greenville, SC 29605
Phone: 864-277-8877
Contact: Matt Kunzweiler
Email: matt.kunzweiler@assaabloy.com
Direct dial: 864-979-7797
PROPOSAL
ID 27743
Quote ID: 45190
Estimate Summary
ID: (None)
Sales Lead ID: (None)
(This proposal ID 27743
printed: 11/29/2022
3:53:06 PM)
Bill to: City of Mauldin
P.O. Box 249
Mauldin, SC 29662
Ship-to: Access Control for City Parks Restrooms
29662
Contact: Jason Hamby Contact:
Phone: 864 991 1066 Phone:
DESCRIPTION:
The Lump Sum Price for All of the Openings is Listed Below
The restrooms below will have individual hand-programmable timers to lock the doors at the desired time.
Once the restroom doors have locked, it will require a key to over-ride the maglocks and enter the restroom.
In the event the restrooms lockdown while occupied a RTE motion and timed RTE pneumatic button will be
installed inside to allow for free egress at all times. The over-ride keys for all park restrooms will be keyed-
alike.
City Park Restrooms - (2) Out-Swinging Doors
Price including listed materials, installation labor, and sales tax.....................................$3,995.00
2 (ea) Alarm Controls, 1200S 12/24VDC Magnetic Lock w/1200lbs Holding Force
2 (ea) Alarm Controls, AM6330 1/4" Spacer Plate for the 1200S Maglock
2 (ea) Bosch, DS160 Request T o Exit Motion Sensor, Light Gray
2 (ea) Camden, CM-5085RPTE 2-3/8" Pushbutton, DPST Pneumatic Timer, Red
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
1 (ea) Camden, CX-247-24 Programmable 7-Day Timer, 24V AC/DC
1 (ea) Altronix, AL175ULX 12/24VDC 1.75A Power Supply w/Fire Disconnect
1 (ea) Altronix, LC2 Standard 6' 3-Wire Power Cord
2 (ea) Y uasa, NP712 12VDC 7AH SLA Battery
1 (ea) Required Hardware, Connectors and Fasteners
1 (ea) Required Low Voltage Maglock Power Wire
We propose to furnish and install the maglock system as listed above. The Altronix power supply, Camden
timer and key over-ride will be located in the upper call box area on the second floor and the low voltage
wiring will be run down in EMT conduit as required to the restrooms. A maglock, RTE Motion, and RTE
Pneumatic button will be installed in each restroom. All low voltage wiring from the ceiling to the associated
device will be in EMT conduit stub-ups as required. We will assist with programming the new timer and
provide additional instruction as needed on the use of the timer. The system will be tested for proper
operation.
Springfield Park
Upper Restrooms - (1) In-Swing Door + (1) Out-Swing Door
Continued on page 2.
14
1 1/29/22, 3:53 PM 141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction
141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction 2/4
Price including listed materials, installation labor, and sales tax.....................................$3,731.00
2 (ea) Alarm Controls, 1200S 12/24VDC Magnetic Lock w/1200lbs Holding Force
2 (ea) Alarm Controls, AM6330 1/4" Spacer Plate for the 1200S Maglock
1 (ea) Alarm Controls, AM6370 Z Bracket for 1200S Maglock
2 (ea) Bosch, DS160 Request T o Exit Motion Sensor, Light Gray
2 (ea) Camden, CM-5085RPTE 2-3/8" Pushbutton, DPST Pneumatic Timer, Red
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
1 (ea) Camden, CX-247-24 Programmable 7-Day Timer, 24V AC/DC
1 (ea) Altronix, AL175ULX 12/24VDC 1.75A Power Supply w/Fire Disconnect
1 (ea) Altronix, LC2 Standard 6' 3-Wire Power Cord
2 (ea) Y uasa, NP712 12VDC 7AH SLA Battery
1 (ea) Required Hardware, Connectors and Fasteners
1 (ea) Required Low Voltage Maglock Power Wire
We propose to furnish and install the maglock system as listed above. The Altronix power supply, Camden
timer and key over-ride will be located in the electrical room next to Men's restroom. A maglock, RTE
Motion, and RTE Pneumatic button will be installed in each restroom. All low voltage wiring will be routed
above the ceiling and EMT conduit stub-ups will be installed from the ceiling to the associated device. We
will assist with programming the new timer and provide additional instruction as needed on the use of the
timer. The system will be tested for proper operation.
Lower Restrooms - (2) In-Swinging Doors
Price including listed materials, installation labor, and sales tax.....................................$3,851.00
2 (ea) Alarm Controls, 1200S 12/24VDC Magnetic Lock w/1200lbs Holding Force
2 (ea) Alarm Controls, AM6330 1/4" Spacer Plate for the 1200S Maglock
2 (ea) Alarm Controls, AM6370 Z Bracket for 1200S Maglock
2 (ea) Bosch, DS160 Request T o Exit Motion Sensor, Light Gray
2 (ea) Camden, CM-5085RPTE 2-3/8" Pushbutton, DPST Pneumatic Timer, Red
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
1 (ea) Camden, CX-247-24 Programmable 7-Day Timer, 24V AC/DC
1 (ea) Altronix, AL175ULX 12/24VDC 1.75A Power Supply w/Fire Disconnect
1 (ea) Altronix, LC2 Standard 6' 3-Wire Power Cord
2 (ea) Y uasa, NP712 12VDC 7AH SLA Battery
1 (ea) Required Hardware, Connectors and Fasteners
1 (ea) Required Low Voltage Maglock Power Wire
We propose to furnish and install the maglock system as listed above. The Altronix power supply, Camden
timer and key over-ride will be located in the electrical room to the left of the Men's bathroom. A maglock,
RTE Motion, and RTE Pneumatic button will be installed in each restroom. All low voltage wiring will be
routed above the ceiling and EMT conduit stub-ups will be installed from the ceiling to the associated
device. We will assist with programming the new timer and provide additional instruction as needed on the
use of the timer. The system will be tested for proper operation.
City Center Park
Price including listed materials, installation labor, and sales tax.....................................$244.00
This location has existing maglocks on the Men's/Women's restrooms.
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
Continued on page 3.
15
1 1/29/22, 3:53 PM 141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction
141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction 3/4
We propose to change out the key cylinder in one of the existing key-switches and to re-wire to a single key-
switch to drop power to both maglocks when activated. The additional key-switch will be removed from the
system. We will assist with programming the new timer and provide additional instruction as needed on the
use of the timer. The system will be tested for proper operation.
Sunset Park
Restrooms @ Circular Drive - (2) Out-Swinging Doors
Price including listed materials, installation labor, and sales tax.....................................$3,611.00
Important Note: New Hollow Metal doors are needed for both the Men's & Women's restrooms
before the maglocks are installed.
2 (ea) Alarm Controls, 1200S 12/24VDC Magnetic Lock w/1200lbs Holding Force
2 (ea) Alarm Controls, AM6330 1/4" Spacer Plate for the 1200S Maglock
2 (ea) Bosch, DS160 Request T o Exit Motion Sensor, Light Gray
2 (ea) Camden, CM-5085RPTE 2-3/8" Pushbutton, DPST Pneumatic Timer, Red
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
1 (ea) Camden, CX-247-24 Programmable 7-Day Timer, 24V AC/DC
1 (ea) Altronix, AL175ULX 12/24VDC 1.75A Power Supply w/Fire Disconnect
1 (ea) Altronix, LC2 Standard 6' 3-Wire Power Cord
2 (ea) Y uasa, NP712 12VDC 7AH SLA Battery
1 (ea) Required Hardware, Connectors and Fasteners
1 (ea) Required Low Voltage Maglock Power Wire
We propose to furnish and install the maglock system as listed above. The Altronix power supply, Camden
timer and key over-ride will be located in the room to the right of the Women's bathroom. A maglock, RTE
Motion, and RTE Pneumatic button will be installed in each restroom. All low voltage wiring will be routed
above the ceiling and EMT conduit stub-ups will be installed from the ceiling to the associated device. We
will assist with programming the new timer and provide additional instruction as needed on the use of the
timer. The system will be tested for proper operation.
Restrooms @ Concession Stand - (2) In-Swinging Doors
Price including listed materials, installation labor, and sales tax.....................................$3,851.00
2 (ea) Alarm Controls, 1200S 12/24VDC Magnetic Lock w/1200lbs Holding Force
2 (ea) Alarm Controls, AM6330 1/4" Spacer Plate for the 1200S Maglock
2 (ea) Alarm Controls, AM6370 Z Bracket for 1200S Maglock
2 (ea) Bosch, DS160 Request T o Exit Motion Sensor, Light Gray
2 (ea) Camden, CM-5085RPTE 2-3/8" Pushbutton, DPST Pneumatic Timer, Red
1 (ea) AC, MCK-4-4 MCK Series Mortise Cylinder Key Switch Station, DPDT , Single-Gang
1 (ea) HGR 3902-118-26D-SC1 Mortise Cylinder-KA
1 (ea) Camden, CX-247-24 Programmable 7-Day Timer, 24V AC/DC
1 (ea) Altronix, AL175ULX 12/24VDC 1.75A Power Supply w/Fire Disconnect
1 (ea) Altronix, LC2 Standard 6' 3-Wire Power Cord
2 (ea) Y uasa, NP712 12VDC 7AH SLA Battery
1 (ea) Required Hardware, Connectors and Fasteners
1 (ea) Required Low Voltage Maglock Power Wire
We propose to furnish and install the maglock system as listed above. The Altronix power supply, Camden
timer and key over-ride will be located in the concession room located on the left side of the building facing
the restrooms.A maglock, RTE Motion, and RTE Pneumatic button will be installed in each restroom. All low
voltage wiring will be routed above the ceiling and EMT conduit stub-ups will be installed from the ceiling to
Continued on page 4.
16
1 1/29/22, 3:53 PM 141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction
141.81.180.22:8082/sm/smcontrolpanel.SMProposalPrintAction 4/4
the associated device. We will assist with programming the new timer and provide additional instruction as
needed on the use of the timer. The system will be tested for proper operation.
To Be Provided By Others:
Permanent use of a 120VAC receptacle or a 120VAC circuit at each Altronix power supply listed above.
These items will need to be provided by a licensed electrician of your choosing if not available.
We hereby propose to complete in accordance with above specification, for the sum of:
Nineteen Thousand Two Hundred Eighty-Three Dollars And Zero Cents $19,283.00
TERMS AND CONDITIONS:
Payment terms to be as follows: Net 30
Prices subject to change if not accepted in: 30 days.
Net 30
Signature:
Date: 11/29/2022
Matt Kunzweiler,
Email: matt.kunzweiler@assaabloy.com
Direct Dial: 864-979-7797
ACCEPTANCE: T erms, price, and specifications on all pages of this proposal are hereby accepted and the
work authorized.
Purchaser: __________________________________ Title: __________________________________
Signature: __________________________________ Date of acceptance: ________
Purchaser's PO number if required for invoicing: _________________ .
(This proposal ID 27743 printed: 11/29/2022 3:53:06 PM)
17
ALARM CONTROLS www.alarmcontrols.com | 800.645.5538
© 2021, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. | Patent pending and/or patent www.assaabloydss.com/patent
7
Features
Standard Features
• 1200S Standard
mag
netic lock
• 1200L
Magnetic lock
with indicating LED
• 1200L
B Magnetic
lock with indicating
LED, bond sensor and
door status sensor
•
Built
-in arc suppression
• Inst
ant release,
no hysteresis
• Self
-drilling TEC screws
• Non-
aluminum parts are
plated to resist corrosion
• E-Z mo
unt header bracket
and template provided
for easy installation, no
special tools required
•
Can be u
sed with any
access control system
• Clea
r anodized (US28)
finish standard
• Limit
ed lifetime warranty
Options
• DURO Duranodic finish
(US 40
) available, specify
when ordering.
• Dres
s covers in polished
chrome and brass
available. See "Magnetic
Lock Accessories"
for options.
Specifications
Certifications & Listings
• UL 294 listed
• UL 10C fi
re rated
• CAN/
ULC-S104 fire
door conformant
• ULC-
S527 listed
• UL 864 l
isted
Holding Force
• 1200 lbs
Dimensions
• Magnet size: 10-1/2" L
x 2-7
/8" H x 1-1/2" W
• Arma
ture size: 7-1/4" L
x 2-3/8" H x 5/8" W
Electrical
• 12 or 24 VDC, field
sele
ctable
• Curr
ent draw: 505 mA at
12 VDC, 260 mA at 24 VDC
• 1200
LB bond sensor has
SPDT 3A relay contacts
Operating Temperature
• +14 to +131F [-10 to +55C]
Bracket mounted magnetic lock with 1200 lbs of holding
force that can be easily installed without special tools and
used with any access control system. Ideal for high-use areas
for traffic control in interior or exterior applications. Available
with LED, bond sensor and door status signalling options.
1200S, 1200L, 1200LB
Single Magnetic Lock
18
16
www.alarmcontrols.com | 800.645.5538
© 2021, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. | Patent pending and/or patent www.assaabloydss.com/patent ALARM CONTROLS
Magnetic LockAccessories
L Brackets
Fixed Single and Double Lock Brackets;
Adjustable Single Lock Mounting Brackets
Z Brackets
Decorative Z Bracket with Integrated Dress Cover
PART NUMBER DESCRIPTION DIMENSIONS FINISH
Fixed Single Lock Brackets:
AM3320 1/4" L bracket for 600 Series
locks 9-7/8"L x 1" x 1-1/2" Clear anodized
(US28)
AM3320C L bracket for 600 Series single
magnetic locks with cover
Clear anodized
(US28)
AM6320 5/16" L bracket for 1200 Series
locks with cover 10-1/2"L x 1-1/2" x 1" Clear anodized
(US28)
AM6320C L bracket for 1200 Series single
magnetic locks with cover
Clear anodized
(US28)
Adjustable Single Lock Brackets:
AM3325 3/16" adjustable L bracket
for 600 Series locks 9-7/8"L x 1-7/8" x 1-3/16" Clear anodized
(US28)
AM6325 1/4" adjustable L bracket
for 1200 Series locks 10-1/2"L x 2-5/16" x 2-5/16" Clear anodized
(US28)
Fixed Double Lock Brackets:
AM3326 5/16" L bracket for 600D and
600DLB Series double locks 19-3/4"L x 1-1/2" x 1" Clear anodized
(US28)
AM6326 1/4 L bracket for 1200D
Series double locks 21"L x 1" x 1-1/2" Clear anodized
(US28)
PART NUMBER DESCRIPTION FINISH
Z Bracket for 600 Series Single Magnetic Locks
AM3370 Z bracket for 600 Series single
magnetic locks
Clear anodized
(US28)
• Fixed single lock L brackets for 600 or 1200 lbs magnetic locks;
Option to include cover.
• Adjustable single lock L bracket for 600 or 1200 lbs magnetic locks
• Fixed double lock L bracket for 600 and 1200 double magnetic locks
• For Duranodic finish US40 (Dark Bronze), please contact the factory
• Adjustable mounting bracket for 600 or 1200 lbs Series Single Magnetic Locks
• For use on in-swinging doors
• AM3370C for magnetic lock models: 600S, 600L and 600LB
− Adjustment range: 2" - 2.75"
− Bracket dimensions: 10"L x 3.5"H
• AM6370C for magnetic lock models: 1200S, 1200L and 1200LB
− Adjustment range: 2.375" - 3.5"
− Bracket dimensions: 10.625"L x 4.25"H
• For Duranodic finish US40 (Dark Bronze), please contact the factory
19
Intrusion Alarm Systems | DS160 Series High Performance Request‑to‑exit Detectors
DS160 Series High Performance
Request‑to‑exit Detectors
www.boschsecurity.com
u Door monitor with sounder alert
u Sequential Logic Input (SLI)
u Internal vertical pointability
u Wrap-around coverage pattern with precise pattern
control
u Up to 64 second adjustable latch time
The DS160 Series consists of the DS160 Detector
(light gray) and the DS161 Detector (black)
specifically designed for Request-to-exit (REX)
applications. With features such as timers, door
monitor with sounder alert, and pointable coverage,
the DS160 and DS161 have the flexibility to meet the
most stringent REX requirements. The exclusive
Sequential Logic Input (SLI) provides added security
that is not offered in any other REX device.
Functions
Sequential Logic Input (SLI)
The SLI terminal allows connection of a second device
to require sequential detection. This eliminates the
possibility that an object that is slid through the door
or underneath the door will activate the detector. This
input can also be used to lock the sensor if motion is
present outside the premises.
Door Monitor
The sensor can monitor a door contact to allow special
control of the internal relay. For example, if the door is
opened within the relay time period, the sensor can be
programmed to halt the timer. If the door is not
opened within a specific time period, the relay can be
programmed to deactivate.
Sounder Alert
An integrated sounder can be programmed to activate
if the door is left open too long. The sounder volume is
fully adjustable to 85 dB.
Keycard Input
The keycard input allows the sensor relay to be
controlled from an external source, such as an access
control system or card reader.
Certifications and approvals
Europe Complies with EN50131‑1 Grade 2
Region Certification
Australia RCM [DS160]
Europe CE 2004/108/EC EMC Directive;
2006/95/EC Low-Voltage Directive;
2011/65/EU Restriction of the use of
certain hazardous substances in electri-
cal and electronic equipment
USA UL ALVY: Access Control Systems Units
(UL294)
20
Installation/configuration notes
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
3 m
(10 ft)
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
1.2 m
(4 ft)
Front View
Mounted on wall above door and mounted on ceiling .
75 m (2.5 ft) in front of the door.
1.5 m
(5 ft)
3 m
(10 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
.75 m
(2.5 ft)
1.5 m
(5 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
Coverage Information
The coverage (detection area) varies depending on the
mounting height above the floor, angle of the lens, and
whether the unit is mounted on a wall above the door
or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x
10 ft) The coverage patterns for the detector at a
height of 2.3 m (7.5 ft) are shown. The coverage
pattern increases or decreases with height and
detector alignment.
Notice
When you mount the unit on the wall and the lens
points straight down, some detection zones point
toward the wall and do not detect movement.
The diagrams depict views of the coverage pattern
with the detector mounted at 2.3 m (7.5 ft) above the
floor with the lens pointed straight down. Zones that
are pointed toward the wall are not shown.
Technical specifications
Environmental
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to
+49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies in
the range from 26 MHz to 1000 MHz at
50 V/m
Complies with Environmental Class II (EN50130-5)
Mechanical
Dimensions: 4.5 cm x 17.1cm x 4.4 cm
(1.80 in. x 6.75 in. x 1.75 in.)
Material:
High impact ABS plastic enclosure
Modes
Power Loss
Default:
Programmable fail-safe or fail-secure modes.
Timer: Programmable reset accumulative or non-reset
counting mode.
Electrical
Current Draw: 8 mA nominal standby current, 39 mA at 12 VDC in
alarm
Voltage:
12 VAC or VDC to 30 VAC or VDC
Alarm Output: Two Form C relay contacts each rated 1 A at 30 VAC
or VDC for resistive loads
2 | DS160 Series High Performance Request‑to‑exit Detectors
21
Indicators: 1 activation LED
Relay Latch
Time:
Adjustable from 0.5 sec to 64 sec.
Ordering information
DS160 Request‑to‑exit Detector
For use in request-to-exit (REX) applications. Provides
PIR 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door
monitor with sounder alert, and pointable coverage.
Order number DS160
DS161 Request‑to‑exit Detector
Black enclosure. For use in Request-to-EXit (REX)
applications. Provides PIR, 2.4 m x 3 m (8 ft x 10 ft)
coverage, timers, door monitor with sounder alert, and
pointable coverage.
Order number DS161
Accessories
TP160 Trim Plate
A light gray trim plate used when mounting the
detector over a standard single-gang box.
Order number TP160
TP161 Trim Plate
A black trim plate used when mounting the sensor
over a standard single-gang box.
Order number TP161
3 | DS160 Series High Performance Request‑to‑exit Detectors
Represented by:
North America: Europe, Middle East, Africa: Asia-Pacific: China: Latin America and Caribbean:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2016 | Data subject to change without notice
2634909195 | en, V10, 10. Mar 2016
22
Page 1 of 3
CM-4085 and CM-5085 Series
Mushroom Push Buttons
INSTALLATION INSTRUCTIONS
Door Activation Devices
Faceplate
Mushroom
PushButton
Connecting Wires
2 White & 2 Red
Pneumatic
Time Delay
Timer Screw
BACK VIEW
5. WIRING
1T
DPST
2T
Momentary: When the switch is pressed it will
provide a change of state on both of the N.O. &
N.C. poles until released
THIS PACKAGE INCLUDES:
4. INSTALLATION1. GENERAL DESCRIPTION
Camden Door Controls CM-4085 and CM-5085 Series Switches are heavy
duty push buttons designed for industrial and commercial applications.
CM-4085 buttons are 1-5/8 (40mm) in diameter, CM-5085 buttons are 2 3/8”
(60mm) in diameter. They are available in red, blue, or green. All switches
feature vandal resistance faceplate 1/4” [6mm] thick brushed aluminum,
optional duranodic (US40) finish is also available.
CM-4085 and CM-5085 series switches are supplied with 1-60 second
pneumatic timer. Pneumatic timer features 6 amps @ 24VDC.
2. SPECIFICATIONS
Voltage 12/24 VDC
Contact Rating 6A @ 24 VDC
Temperature Range -13°F to 158°F (-25°C to 70°C)
Time Range: 1-60 Sec
Timer Life: 1,000,000 activations
Switch Type Momentary
Contact Type: N-C, N-O, Form 2
Standard Finish Brushed Aluminum
Dimensions CM-4185 NARROW:
4 1/2’’ H x 1 3/4’’ W x 2 1/8’’D
(114mm X 44mm x 54mm)
CM-4085 & CM-5085 SINGLE GANG
4 1/2’’ H x 2 3/4’’ W x 2 1/8’’D
(114mm X 70mm x 54mm)
3. APPLICATION
Camden CM-4085 and CM-5085 ‘Request To Exit’ Series Switches with built
in pneumatic time delay are ADA (American Disabilities Act) compliant and
are designed to de-energize electric locking devices (such as magnetic locks)
on egress doors without reliance upon electrical power for their operation.
The mechanical pneumatic timer is also adjustable, allowing flexible time
control as required in the field. Select models comply with UL 294 (standard
for access control systems) and are designed for use in access control
installations meeting IBC (International Building Code) requirements.
CM-5085
Pneumatic time delays require no power to operate. The timing range
is 1 – 60 seconds and is easily adjusted by a thumbscrew. CM-4085 and
5085 Series mushroom push switches are heavy duty push buttons
specially designed and manufactured to meet the stringent demands of
exit control. No set screws are required, due to the bayonet interlocking of
the modular assembly. Buttons are free spinning, for additional protection
against vandalism.
(1) 1-5/8’’ (40mm) Diameter button (CM-4085 series) or 2- 3/8’’ (60mm) Diameter button (CM-5085 Series)
(1) Single Gang Die-cast Aluminum Faceplate
(1) Pneumatic time delay.
(1) Parts Kits
CM-4085
WIRING LAYOUT & COLOR CODING
SWITCH TYPE DPST N.O. DPST N.C.
NORMALLY OPEN WHITE RED
NORMALLY CLOSED WHITE RED
23
Page 2 of 3
CM-4085 AND CM-5085 SERIES MUSHROOM PUSH BUTTONS
INSTALLATION INSTRUCTIONS
7. PARTS INFORMATION
3
4
6
7
8A
9 8B
5
B
C
A
Mushroom button for
CM-4085 Series
2B
Mullion Faceplate for
CM-4185 Series
1B
1A
2A
6. CM-4085 AND CM-5085 SERIES FRONT AND SIDE VIEW
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
CM-4085 & CM-5085 SERIES
BACK VIEW
18/08/20
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
23
4''
[70mm]
41
2''
[114mm]
1
4''
[6mm]
11
4''
[32mm]
21
8''
[54mm]
24
Page 3 of 3
CM-4085 AND CM-5085 SERIES MUSHROOM PUSH BUTTONS
INSTALLATION INSTRUCTIONS
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
File: CM-4085&5085_Manual.indd
Revision: December 16th 2020
Part No: # 40-82B256
ORDERING INFORMATION FOR REPLACEMENT PARTS
ITEM NUMBER PART NUMBER DESCRIPTION
1.
A CM-4085 SERIES
RED MOMENTARY MUSHROOM BUTTON (DIA. 1-5/8’’)
60-66A000
60-66A005 BLUE MOMENTARY MUSHROOM BUTTON (DIA. 1-5/8’’)
60-66A006 GREEN MOMENTARY MUSHROOM BUTTON (DIA. 1-5/8’’)
B CM-5085 SERIES
RED MOMENTARY MUSHROOM BUTTON (DIA. 2-3/8’’)
60-66A007
60-66A009 BLUE MOMENTARY MUSHROOM BUTTON (DIA. 2-3/8’’)
60-66A010 GREEN MOMENTARY MUSHROOM BUTTON (DIA. 2-3/8’’)
2.
A 60-41A003 DIE-CAST ALUMINUM SINGLE GANG FACE PLATE
4 1/2’’H x 2 3/4’’W x 1 3/4’’D (114mm x 70mm x 44mm)
B 60-41A004 DIE-CAST ALUMINUM MULLION FACE PLATE
4 1/2’’H x 1 3/4’’W x 1 3/4’’D (114mm x 44mm x 44mm)
3. 60-40G020 ALUMINUM BLOCK
4. 60-51Z051G20 M4-07 X 16MM PHILLIPS SCREW, CADMIUM PLATED
5. 60-51Z092B08 M3 X 8 HEX HD CAP SCREW
6. 60-40A004 MOUNT BRACKET
7. RM-1000/85M PNEUMATIC TIME DELAY
PARTS KIT
ITEM NUMBER PART NUMBER DESCRIPTION
8. 60-34B038
(A) 6-32 X 3/4 FLAT HEAD PHILLIPS ZINC PLATED SCREW
(B) 6-32 X 3/4 SNAKE EYE TAMPER PROOF SCREW
(C) TAMPER PROOF (SNAKE EYE) KEY
BUTTON ENGRAVED (IN WHITE) OPTIONS
ITEM NUMBER MODEL NUMBER ENGRAVED GRAPHIC DECRIPTION
9.
CM-xxxE EXIT
CM-xxxS EXIT / SORTIE
CM-xxxS SORTIE
CM-xxxESA EXIT / SALIDA
CM-xxxH HANDICAP LOGO
CM-xxxSA SALIDA
COMPATIBLE MOUNTING BOXES
ITEM NUMBER PART NUMBER DESCRIPTION
10.
CM-66 FLUSH BOX & DRESS PLATE, STANDARD DEPTH BOX WITH 7’’ X 7’’ DRESS PLATE HEAVY GAUGE STAINLESS STEEL
CM-31 SLEEVE COVER FOR STANDARD 2 3/4” X 4 1/4” (70MM X 108MM) SURFACE ELECTRICAL BOX. HEAVY GAUGE STAINLESS STEEL
CM-CPC1 VANDAL AND WEATHER RESISTANT CLEAR LIFT COVER
CM-34D SURFACE MOUNT BOX WITH EXTRA DEPTH HEAVY DUTY GREY POLYMER
4 1/2''H x 2 3/4''W x 1 3/4''D [114mm x 70mm x 44mm]
MODEL NUMBERS
MODEL NUMBER
QTY DESCRIPTIONCM-4085
SERIES
CM-5085
SERIES
CM-4185 - 1 SPRING RETURN WITH MULLION FACEPLATE, DPST 1-60 SEC PNEUMATIC TIME DELAY
REQUEST TO EXIT SWITCH
CM-4085 CM-5085 1 SPRING RETURN, DPST 1-60 SEC PNEUMATIC TIME DELAY REQUEST TO EXIT SWITCH
CM-4085RPTE CM-5085RPTE 1 SPRING RETURN, DPST 1-60 SEC PNEUMATIC TIME DELAY, RED BUTTON, ‘PUSH TO EXIT’.
COMPLETE MODEL. NO ‘OPTIONS OR FINISHES’ AVAILABLE
- CM-5085GPTE 1 SPRING RETURN, DPST 1-60 SEC PNEUMATIC TIME DELAY GREEN BUTTON, ‘PUSH TO EXIT’.
COMPLETE MODEL. NO ‘OPTIONS OR FINISHES’ AVAILABLE
25
83
www.alarmcontrols.com | 800.645.5538
© 2021, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. | Patent pending and/or patent www.assaabloydss.com/patent ALARM CONTROLS
Features
Standard Features
• Stainless steel wall plate accepts
sta
ndard 1-1/8” mortise cylinder
• Tamp
er-proof and slotted-
head screws included
• Morti
se Cylinders not included,
available separately (CY-1, CY-1A)
Options
• Momentary or alternate
swi
tch, see model chart
• SPDT or D
PDT, see model chart
• No LED
, green LED, green and
red LEDs, see model chart
• Pneum
atic time delay: 2 to 45
seconds, see model chart
• Add W
P for weather
resistant cover and surface
mount box. Available for
single gang models only.
Specifications
Electrical
• Contacts rated 4A at 28 VDC
• LEDs o
perate on 12
or 24 VDC/VAC
• Swit
ch depth behind plate: 1-1/4”
• Switc
hes terminated
in colored leads
Operating Temperature
• +15 to 120F
Narrow or single gang mortise cylinder key
switch stations. Choose between momentary
action switch that remains active as long as
it’s depressed, or alternate action switch that
alternates between open (disconnected) and
closed (connected) each time it's pressed.
Available with LED options.
MCK Series
Mortise Cylinder Stations
Switch Type 1.75" Wide 1.75" Wide
Green LED
1.75" Wide
Green LED
Red LED
Single Gang Single Gang
Green LED
Single Gang
Green LED
Red LED
SPDT Momentary Action MCK-1 MCK-2 MCK-3 MCK-4* MCK-5* MCK-6*
SPDT Alternate Action MCK-1-2 MCK-2-2 MCK-3-2 MCK-4-2* MCK-5-2* MCK-6-2*
DPDT Momentary Action MCK-1-3 MCK-2-3 MCK-3-3 MCK-4-3* MCK-5-3* MCK-6-3*
DPDT Alternate Action MCK-1-4 MCK-2-4 MCK-3-4 MCK-4-4* MCK-5-4* MCK-6-4*
Pneumatic Time Delay
(2 to 45 seconds) N/A N/A N/A MCK-4-5* MCK-5-5* MCK-6-5*
*Weather resistant cover and surface mount back box available. Add "-WP" to model number for the weatherproof option.
MCK-1 MCK-4
26
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
FEATURES
ELECTRIFIED LOCKS,
RELAYS & TIMERS
RESTROOM CONTROL KITS ANNUNCIATORS TRANSFORMERS POWER SUPPLIES RELAYS & TIMERS DOOR ALARMS MAGNETIC LOCKS ELECTRIC STRIKES
7 DAY PROGRAMMABLE TIMER
CX-247
RELAYS & TIMERS
• MICROPROCESSOR CONTROL
• 15 DAILY OR WEEKLY SCHEDULES
• 16 ‘ON’ AND ‘OFF’ EVENTS
• EXTREMELY COMPACT SIZE
• MEMORY BACKUP
• EASY MOUNTING
• ’H’ MODELS FEA TURE ’FIRST-MAN-IN’
FUNCTION (HOLIDAY/SNOW DAY)
• 16A@ 30 V DC CONTACTS
• 3 YEAR WARRANTY
Camden Door Controls is an ultra compact programmable 7 day timer.
It features a large digital display, and 16 flexible easy-to-program on/off schedules.
An internal permacell keeps the programs and display readable in the event of a
power loss or brownout.
The CX-247 can be ordered to operate on 12V, or 24V, AC/DC. The heavy duty relay
contacts are rated at 16 amps @ 30 VDC.
The ”First-Man-In” option maintains security during ”snow-days”, sick days,
employee absenteeism. The timer schedule does not engage, (and the door
remains locked) until the ”First-Man-In” activates the entry system.
DESCRIPTION
CX-247
APPLICATION
The CX-247 can automatically and reliably control electrified locks and magnets,
automatic overhead and pedestrian doors, or control lighting or energy
management devices.
The ”First-Man-In” option eliminates the need for a complex 365-day timer.
The compact size and dust and water resistant enclosure, ensure it will meet
virtually any timing application.
27
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
MKTG-LIT-SP-247-R5
7 DAY PROGRAMMABLE TIMER
TYPICAL APPLICATION
SPECIFICATIONS
CX -247-1 2 CX-247-24
OPERATING
VOLTAGE: 12V AC/DC 24 V AC/DC
DIMENSIONS: 2 3/8” H x 2 3/8” W x 1 1/4” D
( 60mm x 60mm x 32mm )
MOUNTING: 4 MOUNTING SCREWS
ENCLOSURE: WHITE ABS PLASTIC
CURRENT DRAW: 0.1 MA IDLE, 10 MA OPERATING
RESPONSE TIME: .03 SECONDS
BACK UP: INTERNAL PERMACELL
PROGRAMS: 16
RELAY OUTPUTS: 1 X FORM ’C’ (SPDT)
CONTACT RATING: 16 AMPS @ 30 VAC
ELECTRICAL LIFE: 250,000 @ RATED CAPACITY
DOOR
O PERAT O R
O R
AC/D C
POWE R
ELECTR I C
LOC K
CX-247
ORDERING INFORMATION
MODEL DESCRIPTION
CX-247-12: 7 DA Y TIMER - 12V
CX-247-24: 7 DA Y TIMER - 24V
CX-247H-12: 7 DA Y TIMER WITH FIRST-MAN-IN-FUNCTION - 12V
CX-247H-24: 7 DA Y TIMER WITH FIRST-MAN-IN-FUNCTION - 24V
28
Input
Voltage
115VAC, 60Hz, 0.6
A
Trigger
Access control trigger input
Outputs
Two (2)
Class 2 Rated power-limited outputs
-
Fail-Safe/Fail-Secure lock output (switched)
-
Auxiliary power output (unswitched)
Voltage
12VDC or 24VDC selectable
Current
1.75A continuous max.
Other
Short circuit and thermal overload protection
Back-up Battery
(not included)
Type
Sealed lead acid or gel type
Failover
Upon AC loss, instantaneous
Fire Alarm Disconnect
Supervised
Latching or non-latching
Supervision
AC Failure
Form “C” contacts
Indicators (LED)
Input
Input voltage is present
DC Output
Powered
Agency Listings
UL
UL294 (Access Control)
cUL
CSA Standard C22.2
No.205-M1983,
Signal Equipment
CSFM
CSFM Approved
Physical and Environmental
Dimensions (H x W x D)
Enclosure:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
Shipping:
15” x 13.875” x 4.75” (381mm x 352.4mm x 120.6mm)
Enclosure
accommodates up to two (2) 12VDC/7AH batteries
Weight (approx.)
Product:
8.4 lb. (3.81 kg)
Shipping:
9.4 lb. (4.26 kg)
Temperature
Operating:
0ºC to 49ºC (32ºF to 120ºF)
Storage:
– 20ºC to 70ºC (– 4ºF to 158ºF)
Relative Humidity
85% +/
– 5%
BTU/Hr. (approx.)
12VDC: 11 BTU/Hr.
24VDC:
22 BTU/Hr.
Specifications
AL175ULX
AL175ULX
Switching Power Supply/Charger
Altronix AL175ULX Switching Power Supply/Charger converts a 115VAC 60Hz input into
two (2) individually PTC protected auto-resettable 12VDC or 24VDC outputs.
Lifetime Warranty
Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA
phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com
Rev. 07222022
29
Source: City of Mauldin website. First collected Nov 7, 2026.