RecordWell Data

Historic Preservation Commission Meeting — Agenda Packet

Town of Bluffton · Beaufort County · Historic Preservation Commission · meeting of Jun 3, 2026 · Agenda packets

Open the original document More from Town of Bluffton

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Historic Preservation Commission Meeting Wednesday, June 03, 2026 at 6:00 PM Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20 Bridge Street, Bluffton, SC AGENDA This meeting can be viewed live on BCTV, on Sparklight Channel 9 and 417 or on Spectrum Channel 1304. I. CALL TO ORDER II. ROLL CALL III. NOTICE REGARDING ADJOURNMENT The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by a majority vote of the Commission Members present. Items which have not been heard before 9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined by the Commission Members. IV. ADOPTION OF MINUTES 1. May 6, 2026 Minutes V. PUBLIC COMMENT VI. OLD BUSINESS VII. NEW BUSINESS 1. Certificate of Appropriateness (95 Green Street): A request by Glenda Mikulak Roberts, Applicant and Owner, for review of a Certificate of Appropriateness-HD to construct a new 1.5-story house of approximately 2,342 SF at 95 Green Street in OId Town Bluffton Historic District and zoned Neighborhood General-HD. (COFA-08-24-019275)(Staff-Charlotte Moore) VIII. DISCUSSION 1. Historic District Monthly Update. (Staff) 2. Discussion regarding proposed amendments to non-contributing structures in Old Town Bluffton Historic District. No attachments. (Staff) IX. ADJOURNMENT NEXT MEETING DATE: Wednesday, July 1, 2026 Page 1 Town of Bluffton, SC Historic Preservation Commission Meeting Agenda June 03, 2026 “FOIA Compliance – Public notification of this meeting has been published and posted in compliance with the Freedom of Information Act and the Town of Bluffton policies.” In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA compatible. Auditory accommodations are available. Any person requiring further accommodation should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the scheduled event. Executive Session – The public body may vote to go into executive session for any item identified for action on the agenda. *Please note that each member of the public may speak at one public comment session and a form must be filled out and given to the Town Clerk. To submit a public comment online, please click here: https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60 Public comment is limited to 3 minutes per speaker. Page 2 Historic Preservation Commission Meeting Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20 Bridge Street, Bluffton, SC May 06, 2026 I. CALL TO ORDER Chairman DePauw called the meeting to order at 6pm. II. ROLL CALL PRESENT Chairman Joe DePauw Vice Chair Carletha Frazier Commissioner Jim Hess Commissioner Tim Probst Commissioner Lisa Sulka Commissioner Michael Sutcliffe ABSENT Commissioner Debbie Wunder III. ADOPTION OF MINUTES 1. March 4, 2026 Minutes Commissioner Sulka made a motion to adopt the minutes as written. Seconded by Vice Chair Frazier. Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe All were in favor and the motion passed. IV. PUBLIC COMMENT V. OLD BUSINESS VI. NEW BUSINESS 1. Certificate of Appropriateness (204 Bluffton Road): A request by Thomas Michaels, Jr. (SM7 Design, LLC), Applicant, on behalf of 204 Bluffton Road, LLC, Owner, for approval of a Certificate of Appropriateness to allow the construction of a 3-story 3,978 SF Main Street Building at 204 Bluffton Road. The property is in the Promenade development in Old Town Historic District and zoned Neighborhood Core-Historic District (NC-HD). (COFA-12-25-020072) (Staff-Charlotte Moore) Staff presented. The applicant was present. The commissioners had questions regarding column spacing on the front porch, which the UDO requires to be wider than tall. The commissioners discussed window placement on the side elevations, transom window operability, door configurations on upper floors, and windowsill details. There was discussion regarding the service yard door, brick material selection, and electric meter screening. Page 3 Section IV. Item #1. Town of Bluffton, SC Historic Preservation Commission Meeting Minutes May 06, 2026 Motion made by Commissioner Sulka made a motion to approve the application with the following conditions: 1. Show all windows by type (i.e., label windows). 2. Show all doors by type (i.e., label doors). 3. Identify the roof configuration (mentioned to be standing seam metal at the HPC meeting). 4. Revise plan to show porch ceilings with pressure-treated wood or cementitious board. 5. Provide railing details (for porches and the staircase). 6. Identify the brick to be used for the front porch columns and ground-floor wall cladding (mentioned to be Savannah Grey at the HPC meeting). 7. If electric meters must be relocated, they must be screened with landscaping or another screening method as determined by the HPRC. 8. Provide proof of a Right-of-Way encroachment permit for South Carolina Department of Transportation for any work within Bluffton Road right-of-way. 9. The columns and posts must be redesigned and reviewed by the Historic Preservation Review Committee (HPRC) for approval. and the following were determined to be appropriate: 1.The use of powder-coated aluminum for the porch railings, balusters and handrails. 2. The use of Glastra material for windows and doors. 3. The placement of windows on the right and left elevations. Seconded by Commissioner Hess. Chairman DePauw made a motion to amend the motion to include the following conditions: 1. For all porch doors with a panel door, install door hardware to give the appearance of an operable door. 2. Provide sills for all window casings. and include that the following is determined to be appropriate: 1. The use of fixed transom windows on the right and left elevations. Seconded by Commissioner Sulka. Voting Yea to amend the motion: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe All were in favor and the motion passed. Voting Yea to the amended motion: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe All were in favor and the motion passed. Page 4 Section IV. Item #1. Town of Bluffton, SC Historic Preservation Commission Meeting Minutes May 06, 2026 VII. DISCUSSION 1. Historic District Monthly Update. (Staff) Staff reviewed the monthly report. The Commissioners had no questions. VIII. ADJOURNMENT Commissioner Hess made a motion to adjourn. Seconded by Commissioner Sulka. Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe All were in favor and the motion passed. The meeting adjourned at 6:46pm. Page 5 Section IV. Item #1. 95 Green Street – Certificate of Appropriateness Historic Preservation Commission HISTORIC PRESERVATION COMMISSION STAFF REPORT Department of Growth Management MEETING DATE: June 3, 2026 PROJECT: COFA-08-24-019275 95 Green Street – New Construction of Single-family House APPLICANT: Glenda Mikulak Roberts PROPERTY OWNER: Glenda Mukulak Roberts PROJECT MANAGER: Charlotte Moore, AICP, Principal Planner APPLICATION REQUEST: The Applicant and Property Owner, Glenda Mikulak Roberts, requests that the Historic Preservation Commission (HPC) approve the following application: A Certificate of Appropriateness to construct a 1.5-story single-family residence of approximately 2,342 SF at 95 Green Street in Old Town Bluffton Historic District, and within the Neighborhood General-HD (NG-HD) zoning district. INTRODUCTION: The house will be located at 95 Green Street, an unpaved road without sidewalks, on a 0.33-acre double-frontage lot that includes an existing carriage house that was constructed about 2014. The house will front Green Street and the rear yard will be adjacent to Hickory Trace, also an unpaved road. A 36-inch live oak tree is located in the middle of the lot and will be preserved. The existing 1.5-story carriage house features a side-gable 5-V metal roof, inset balcony, 2/2 window configurations, square wood columns with bases and capitals, fiber cementitious horizontal lap siding with board and batten siding underneath the gables, and operable wood shutters (Attachment 10). The proposed main structure has characteristics of a Vernacular House Building Type with a roof ridge that is parallel to the front façade, includes side-facing gables, and a full- façade front porch. However, the footprint is larger than is permitted by the Unified Development Ordinance (1,800SF maximum vs. 1,912SF proposed) and the massing is inconsistent with this building type, particularly the middle block that extends above the Green Street-facing block. As the structure is not characteristic of other building types permitted in the NG-HD District, it is reviewed as an Additional Building Type in accordance with UDO Sec. 5.15.5.C. The main structure has similar characteristics to the carriage house with some variations. The structure will be located on a raised concrete slab with tabby stucco coating. The front Page 6 Section VII. Item #1. June 3, 2026 Page 2 95 Green Street – Certificate of Appropriateness Historic Preservation Commission porch and rear stoop will be located on CMU piers with unspecified brick veneer that will be inset with pressure-treated wood horizontal boards. Wall cladding, including the gables, will be Hardie board and batten (12” o.c.). A full-façade front porch on the Green Street elevation features square wood columns with bases and capitals and a wood balustrade, as does the inset porch on the left elevation. All windows are 2/2 fiberglass double-hung except for shed dormer casement windows in the middle block and one in the rear elevation. Exterior doors are a combination of metal clad, mahogany wood with a ¾ glass inset, and fiberglass (which is not a permitted material). In addition to the main structure, a swimming pool, pool deck with pavers, and living and privacy fences are proposed. A Concept Plan was reviewed twice for this project. The Historic Preservation Review Committee dates are September 3, 2024 and February 23, 2026. A response to the more recent HPRC comments is provided in Attachment 9. REVIEW CRITERIA & ANALYSIS: In its review of this COFA-HD application, Town Staff and the Historic Preservation Commission are required to consider the criteria set forth in Unified Development Ordinance (UDO) Section 3.18.3 (COFA-HD, Application Review Criteria), applying the standards and guidelines of UDO Sec. 5.15, Old Town Bluffton Historic District. The intent of the standards and guidelines is, in part, to provide guidance and ensure consistent development without discouraging creativity or forcing the replication of historic models. The applicable criteria of UDO Sec.3.18.3 are provided below followed by a Staff Finding based upon review of the application submittals to date. 1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town Master Plan. a. Finding. The application is consistent with the principles set forth in the Old Town Master Plan. The Old Town Master Plan states that “The built environment, in particular the historic structures scattered throughout Old Town, should be protected and enhanced. While it is of great importance to save and restore historic structures, it is just as important to add to the built environment in a way that makes Old Town more complete.” Old Town Bluffton Historic District is a locally designated historic district. The main structure has been designed to be sympathetic to the architectural character of neighboring structures and will enhance the neighborhood by adding architectural variety provided that the conditions noted in #2 of this Section are met and determinations by HPC made. However, the massing of the middle block is of concern as it is taller than the block facing Green Street. Page 7 Section VII. Item #1. June 3, 2026 Page 3 95 Green Street – Certificate of Appropriateness Historic Preservation Commission b. Finding. The Old Town Master Plan initiatives also include the adoption of a form-based code that included architectural standards for structures located within the Old Town Bluffton Historic District. These standards are included in Article 5 of the UDO. The new construction will be in conformance with those standards if the conditions noted in #2 of this Section are met and determinations by HPC made. c. Finding. The Old Town Master Plan initiatives also promote preservation and protection of the legacy of the Old Town Bluffton Historic District through additions to the built environment which make Old Town more complete. The addition of new buildings contributes to the district as well as helps to provide completeness to the neighborhood and overall district. 2. Section 3.18.3.C. The application must be in conformance with applicable provisions provided in Article 5, Design Standards. a. Findings. Town Staff finds that if the conditions noted below are met and/or approved by the HPC, the proposed structure will be in conformance with applicable provisions provided in Article 5: (1) Service Yard (UDO Sec. 5.15.5.F.9.): Utility meters must be screened from public view per the UDO; however, the electric utility requires that the screening enclosure not include a gate. Therefore, the gate must be removed or, alternatively, landscaping may be used to screen the meter. (2) Chimney (UDO Sec. 5.15.6.E.8.c. and d.): The chimney is proposed to have a bishop’s cap. While this is a traditional style for Old Town, a single bishop’s cap applied to residential dwellings is increasingly disproportionately large. Therefore, it is recommended that at least two bishop’s caps be applied to the chimney. Additionally, the spark arrestor must be concealed with the within the chimney. (3) Building Walls (UDO Sec. 5.15.6.G.3.): Hardie board and batten is proposed for building walls, including underneath the gable. The carriage house has board and batten cladding but horizontal lap siding underneath the gables. For consistency, it is recommended that this pattern also be applied to the main structure. If a metal roof is proposed, this would also break up the verticality of the structure (Note: shingle material is mentioned in the application and the plan set, but a metal roof is shown). (4) Brick (UDO Sec. 5.15.6.G.3.h.): UDO states that for the use of brick, “[w]herever possible, green building materials…including recycled content sheathing, siding composed of reclaimed or recycled material, salvaged masonry brick or block, and locally produced stone or brick” should be used. Page 8 Section VII. Item #1. June 3, 2026 Page 4 95 Green Street – Certificate of Appropriateness Historic Preservation Commission Information regarding the proposed brick has not been provided for the piers. In the recent past, Savannah Grey or similar tumbled brownish-grey brick has been approved by the HPC. It is recommended that a sample brick or cut sheet be provided for Historic Preservation Review Committee approval. (5) Doors (UDO Sec. 5.15.5.6.I.2.b.): The door on the rear elevation is proposed to be fiberglass. The UDO permits only wood, metal or metal-clad. (6) Windows (UDO Sec. 5.15.6.I.3.b.): For the main house, fixed windows are proposed on the Right and Rear elevations, which is not a permitted configuration. These windows must be changed to a casement operation unless otherwise approved by HPC. (7) Roof (UDO Sec. 5.15.6.J.): The UDO permits both metal (galvanized, copper, aluminum, zinc-alum) and shingles (metal, dimensional asphalt, slate and composite slate) roofs. The project analysis sheet and the flashing details sheet suggest that asphalt shingles will be used; however, the drawings show a metal roof. The correct roof must be shown and include the specific material and configuration per UDO Sec. 5.15.6.J.). (8) Trim: Certain trim pieces on the Front Door Elevation and Sill details (Sheet A6.1) show “hardie plan or azek.” Azek is not a UDO permitted material. The inclusion of this material may be an error based on the Applicant’s response to HPRC comments (Attachment 9). (9) Shutters (UDO Sec. 5.15.6.M.): Shutters are not a requirement, but they are provided on the carriage house. While the structure includes adequate fenestration, there are portions of wall area that lack visual interest and/or spacing between windows is wide (such as the front porch). Therefore, it is recommended that shutters be provided that are consistent with UDO Sec. 5.15.6.M. 3. Section 3.18.3.D. Consistency with the nature and character of the surrounding area and consistency of the structure with the scale, form and building proportions of the surrounding neighborhood. Finding . The mass and scale of the main structure is appropriate for its location and the architectural detailing, with revisions to address the items in #2 above, will be sensitive to the neighboring properties. However, the mass and scale of the Carriage House appears disproportionately larger than the main house. 4. Section 3.18.3.H. The application must comply with applicable requirements in the Applications Manual. Page 9 Section VII. Item #1. June 3, 2026 Page 5 95 Green Street – Certificate of Appropriateness Historic Preservation Commission Finding. The Certificate of Appropriateness Application has been reviewed by Town Staff and has been determined to be complete except for the applicable items in #2. STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the standards and guidelines set forth in the UDO as they pertain to applications using the review criteria established in the UDO and to take appropriate action as granted by the powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance have been met and recommends that the Historic Preservation Commission approve the application subject to the following conditions and determinations: Conditions: 1. Remove the gate for the utility meter screening fence or, alternatively, provide landscaping to screen the meter. 2. Provide two bishop’s caps for the chimney cap and conceal the spark arrestor within the chimney. 3. Provide horizontal lap siding underneath the gables to match the cladding of the carriage house. 4. Provide the source and type of brick proposed to be used for review and approval by the HPRC. 5. Provide a rear elevation door that is wood, metal or metal-clad. 6. Change fixed windows to casement windows (or other window configuration that may be approved by HPC). 7. Consistent with UDO Sec. 5.15.6.J., provide the exact roof material and configuration. 8. Remove references to Azek material (unless otherwise approved by the HPC as an alternate material). 9. Provide shutters that are consistent with UDO Sec. 5.15.6.M. Determination: A determination from the HPC is needed regarding the appropriateness of the following: 1. The massing of the middle block of the structure, as it is taller than the Green Street front elevation block. HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to take the following actions with respect to this application: 1. Approve the application as submitted by the Applicant; Page 10 Section VII. Item #1. June 3, 2026 Page 6 95 Green Street – Certificate of Appropriateness Historic Preservation Commission 2. Approve the application with conditions; or 3. Deny the application as submitted by the Applicant. ATTACHMENTS: 1. Application 2. Location & Zoning Map 3. Photos 4. Survey 5. Site Plan 6. Narrative 7. Architectural Plans 8. Landscape Plan 9. Response to HPRC Comments 10. Carriage House Plans (2013) Page 11 Section VII. Item #1. ATTACHMENT 1 Page 12 Section VII. Item #1. ATTACHMENT 1 Page 13 Section VII. Item #1. ATTACHMENT 1 Page 14 Section VII. Item #1. ATTACHMENT 1 Page 15 Section VII. Item #1. LOCATION & ZONING MAP 95 Green Street Neighborhood General-HD District ATTACHMENT 2 Page 16 Section VII. Item #1. DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ Designer Author 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A0.6 ATTACHMENT 3 Page 17 Section VII. Item #1. ATTACHMENT 4 Page 18 Section VII. Item #1. HOUSE 26'-00" AMSL 24.00'FG 23.00'FG 24.25'TC 24.00'FG24.00'FG 23.50'FG 24.00'TC 24.25'TC 24.00'FG24.00'FG 24.00'FG 23 24.25'TC 24.00'TC UP DW OVEN PHONE CABLE 65' - 5 1/2" 36' - 0" 16' - 4 1/4"15' - 0" 34' - 1 1/4" 2' - 11" 3' - 9 1/2" 3' - 0" 7' - 0" 16' - 0"8' - 6 13/16"17' - 10 1/2"8' - 1 3/16" 9' - 4 1/4"5' - 10"9' - 4 1/2"11' - 5 1/4" 6' - 5"14' - 10"14' - 9" 18' - 0 1/2" 5' - 3"5' - 4" 7' - 2"2' - 8" 5' - 7 1/4" JOYOUS TWO PERSON SAUNA 1' - 2"3' - 1"1' - 2" 30" x 60" 1' - 10 1/2" 1' - 2"4' - 8"1' - 2" 7' - 1" 9" 14' - 11" 65' - 5 1/2" 7' - 1" ROBINS ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LNDRY/ENTRY TILE FLR. 10' 1 1/8" CLG. HT. M. CLST WOOD FLR. 10'-1 1/8" CLG. HT. M. BATH TILE FLR. 10'-1 1/8" CLG. HT. MASTER BEDROOM WOOD FLR. 10'-1 1 /8" CLG. HT. PWDR WOOD FLR. 10'-1 1/8" CLG. HT. PANTRY WOOD FLR. 10'-1 1/8" CLG. HT. HALL WOOD FLR. 10'-1 1/8" CLG. HT. KITCHEN WOOD FLR. 10'-1 1/8" CLG. HT. D. ROOM WOOD FLR. 10'-1 1/8" CLG. HT. L. ROOM WOOD-FLR. 10'-1 1/8" CLG. HT. VANITY AREA 10' - 0"2' - 10"8' - 8" 36' - 0" 4' - 2" 2' - 2 1/2" DESK 5' - 8 3/4"6' - 5"5' - 8 3/4" 5' - 8 1/2" 6' - 3" 2' - 10 1/4" BATH #2 TILE FLR. 10' 1 1/8" CLG. HT. CLOSET WOOD FLR. 10' 1 1/8" CLG. HT. SAFE ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LOW AREA UNDER LANDING LIN. 4' - 1 1/4" 3' - 4 3/4" FRONT PORCH T&G FLR. SIDE PORCH T&G P.T. FLR. 17' - 10 1/2" 3' - 10 1/4"10' - 8 1/4" 5' - 1 3/4" 5' - 1" 4' - 6 1/4"2' - 6"7' - 10 3/4" 3' - 11 1/2" 9' - 0 1/2" 5' - 11 1/2" 11' - 0 1/2" 6' - 1" 4' - 0 7/8" 4" 4" 4' - 0" 3' - 0 21/32" meter head trash recept. at garage 7' - 5 1/2"7' - 5 1/2" 3' - 6" 3' - 6 1/16" 8' - 11 1/4"8' - 11 1/4" 7' - 8" 3' - 8" 8 5/8" W/D STACK 2' - 8 1/2"10' - 10"9' - 1 1/2"9' - 4 7/16"2' - 11"10' - 3 9/16"7' - 8"9' - 8"2' - 10 1/2" 5' - 10 1/4" 12' - 1 3/4" 12' - 2" 5' - 10" 1' - 0 1/2" 9"3" 3" 3' - 10 1/2" 7' - 4 3/4" 6' - 4" 10' - 8" 8' - 0"8' - 0"8' - 6 13/16"4' - 5 17/32"4' - 5 3/4"4' - 5 3/4"4' - 5 15/32"4' - 2 3/4"3' - 10 7/16"7' - 5 1/2"7' - 5 1/2" 2' - 10"9' - 10" 4 5 19 18 15 16 17 14 13 2 1 3 12 11 10 8 9 76 open door 3/0 X 6/0 WOOD GATE 3/0 X 6/0 WOOD GATE 10A 1ST FL 26.00' NAVD88 FP 25.917' NAVD88 RP 25.83' NAVD88 SY 23.4' NAVD88 FP 25.917' NAVD88 TEMPERED GLASS 5 1/2" BRICK HEARTH 3' - 4 1/2"2' - 0" 2' - 8 1/2"1' - 2"4' - 8"1' - 2"4' - 9" EXISTING CARRIAGE HOUSE RAMP DOWN 7' - 8 3/4" 6 1/4"6 1/4" 4' - 8" HOUSE 26'-00" AMSL 24.00'FG 23.00'FG 24.25'TC 24.00'FG24.00'FG 23.50'FG 24.00'TC 24.25'TC RAMP 15' x 35' POOL RAMP 24.00'FG24.00'FG 24.00'FG 23 24.25'TC 24.00'TC ATTACHMENT 5 Page 19 Section VII. Item #1. ATTACHMENT 6 Page 20 Section VII. Item #1. GENERAL NOTES · NOTES TO GENERAL CONTRACTORS: THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED S ERVICE AGREEMENT BETWEEN THE OWNER AND LOW TIDE DESIGNS. THEY ARE TO BE USED IN CONJUNCTION WITH STRUCTURAL AND OTHER ENGINEERING REQUIREMENTS FOR A BUILDING PERMI T. · THESE DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION D OCUMENTS · SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS THAT ARE REQUIRE BY CODE. CODE COMPLIA NCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION AND TIE DOWN REQUIREMENTS · SEPARATE MECHANICAL AND PLUMBING ENGINEERING DOCUME NTS MAY BE PROVIDED WHICH WOULD INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCU LATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE RESIDENTIAL DESIGNERS BAS IC LAYOUT AND SELECTIONS · SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDE D WHICH INDICATE ADDITIONAL SITE PREP PLANNING, AND DRAINAGE. · SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER/OWNERS REPRESENTATIVE OR BUILDER.. · BY APPLYING FOR A BUILDING PERMIT AND /OF CONSTRUCT ING THE PROJECT REPRESENTED HER IN, THE OWNER AGREES TO LIMIT THE LIABILITY OF THE RESI DENTIAL DESIGNER TO THE OWNER OF THE PROJECT FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER OR CLAIMS OF EXPENSE FOR ANY SUCH ITEMS TO THE RESIDENTIAL DESIG NERS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. · THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE RES IDENTIAL DESIGNER AND HAVE BEEN PREPARED SPECIFICALLY AND ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE PARTICIPATION OF THE RESIDENT IAL DESIGNER. REPRODUCTION IS STRICTLY PROHIBITED. THE RESIDENTIAL DESIGNER SHALL BE DEEMED THE AUTHOR AND OWNER OF THESE DOCUMENTS AND SHALL RETAIN COMMON LOW STATUTO RY AND OTHER RESERVED RIGHTS, INCLUDING THE COPY RIGHT. · THIS WRITTEN NOTICE BY THE SOUTH CAROLINA REGULATIO NS TO THE PERMITTING AUTHORITY AND BUILDING OWNER THAT THE RESIDENTIAL DESIGNER AT LOW TIDE DESIGNS HAVE NOT BEEN HIRED TO PROVIDE MINIMUM CONSTRUCTION ADMINISTRATION SERVICE S ON THE FOLLOWING PROJECT. · FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRA CTOR WILL REQUEST CLARIFICATION FROM THE RESIDENTIAL DESIGNER BEFORE PROCEEDING. · CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD. ANY DISCREPANCIES WILL BE BROUGHT TO THE RESIDENTIAL DESIGN BEFORE PROCEEDING . · INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK . EVERY AT TEMPTS HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDI TIONS. · WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH TH E ENGINEERING DRAWINGS THE GENERAL CONTRACTOR SHALL REQUEST CLARIFICATIONS FROM THE RE SIDENTIAL DESIGNER BEFORE PROCEEDING. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION MANAGEMENT OR OBSERVATION ON THIS PROJECT. DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA CS SHEET LIST SHEET NUMBER SHEET NAME CS COVER SHEET A0.0 ORIGINAL SITE PLAN A0.1 SITE PLAN A0.2 DRAINAGE A0.3 STREETSCAPE A0.5 STORM WATER INFORMATION LS LANDSCAPING A1.1 FOUNDATION PLAN A2.1 FIRST FLOOR PLAN A2.2 SECOND FLOOR PLAN A2.3 ROOF PLAN A3.1 EXTERIOR ELEVATIONS A3.2 EXTERIOR ELEVATIONS A3.3 3D EXTERIOR VIEWS A4.1 BUILDING SECTIONS A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 DETAILS A4.5 FLASHING DETAILS A5.0 WINDOW & DOOR SCHEDULE A5.1 WINDOW DETAILS A5.2 WINDOW DETAILS A6.1 DOOR DETAILS E2.1 FIRST FLOOR ELECTRICAL PLAN E2.2 SECOND FLOOR ELECTRICAL PLAN S0.1 STRUCTURAL BUILDING CODE SUMMARY NAME OF PROJECT: ADDRESS: PROPOSED USE: OWNER/CONTACT: CODE ENFORCEMENT JURISDICATION: DESIGNER OF RECORD DESIGNER ELECTRICAL PLUMBING MECHANICAL STRUCTURAL CIVIL LANDSCAPER BUILDING DATA OCCUPANCY CLASSIFICATION MIXED OCCUPANCY CONSTRUCTION TYPE MIXED CONSTRUCTION SPRINKLERED FIRE DISTRICT BUILDING HEIGHT 24'-2 13/16" GLENDA AND BILLY MIKULAK LOT #2 AND 2A GREEN STREET BLUFFTON, SOUTH CAROLINA RESIDENTIAL GLENDA MIKULAK TOWN OF BLUFFTON, SC LOW TIDE DESIGNS __________ BLUFFTON, SC 29910 843-815-9575 __________ __________ __________ __________ MICHAEL BROCK RLA __________ __________ __________ __________ __________ PORT ROYAL SC __________ __________ __________ __________ __________ 843.540.6407 RESIDENTIAL R-3 NO SEPARATION I-A I-B II-B III-A III-B IV V-A V-B NO TYPE NO NO BUILDING STORIES 1.5 1 3D FRONT VIEW 1-COVER ATTACHMENT 7 Page 21 Section VII. Item #1. DN 4' - 10" 65' - 5 1/2" 7' - 0" 16' - 8" 34' - 0 1/4" 14' - 9 1/4" 37' - 5 9/16" 6' - 0" 21' - 11 15/16" 16' - 11 1/2" 3' - 6" 30' - 2 3/4" 14' - 9 1/4" 36' - 0" 6' - 0" 6' - 2 1/4" 15' - 2 1/2" 14' - 7 1/4" 4' - 10" 16' - 0" 8' - 6 13/16" 17' - 10 1/2" 8' - 1 3/16" 14' - 11" 6' - 11" 5' - 8 3/4" 6' - 5" 5' - 8 3/4" 7' - 11 1/2" 5' - 11 1/2" 11' - 0 1/2" 19' - 0" 6' - 2 1/4" 15' - 2 1/2" 14' - 7 1/4" 4' - 3 1/2" 6' - 9" 8' - 10" 4' - 10" 5' - 4" 10' - 8 1/4" 5' - 11 3/4" 3' - 9 1/2" 4' - 1 5/16" 9' - 7" 14' - 10" 11' - 7" 8' - 2 7/8" 14' - 9 1/4" 6" 4' - 4" 22' - 0 1/8" 6 1/8" 4' - 5" 6 1/8" 8' - 6 5/8" 8 1/4"9' - 10"2' - 10"8' - 8"2' - 10"9' - 10"10 1/4" 3 3/4"1 3/4" 36' - 0" 6' - 5" 6"5' - 8 3/4" 6' - 5" 5' - 8 3/4" 6" 4' - 4" 6' - 5" 6" F1 F1 F1 F2 F3 F14 F14 F14 F14 F14 THESE PIERS BRICK TWO SIDES THESE PIERS BRICK TWO SIDES THESE PIERS BRICK TWO SIDES F14 8" THICKENED SLAB UNDER FIREPLACE PROVIDE GAS STUB PROVIDE GAS STUB COOK TOP 2 X 8 16" PT FLOOR JOIST 2 X 8 16" PT FLOOR JOIST 2 X 8 16" PT FLOOR JOIST 1ST FL 26.00' NAVD88 FP 25.917' NAVD88 RP 25.83' NAVD88 SY 23.4' NAVD88 FP 25.917' NAVD88 RECESS FLOOR 4" DWN DWN POOL TERRACE POOL BY CONTRACTOR 5' DEEP W/ RAMP 1' - 4" 1' - 4" 2' - 0" 2' - 0" 6" 6" DWN 1" DWN 1" DWN 1" 1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4"1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4" DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A1.1 1/4" = 1'-0"1 FOUNDATION PLAN MASTER NOTE SCHEDULE NOTE NUMBER NOTE F1 4" THICK 3,000 PSI CONCRETE SLAB REINF. W/ 6X6 #10/#10 W.W.M. ON 6 MIL POLYETHYLENE VAPOR BARRIER ON CLEAN, DRY, COMPACTED, TERMITE TREATED EARTH FILL. F2 8" WIDE X 12" DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONC. SLAB INTO FOOTING. F3 4" THICK, 3,000 PSI CONCRETE SLAB REINF. W/ 6X6 #10/#10 W.W.M. ON CLEAN, DRY, TREATED, COMPACTED EARTH FILL. F4 16" X 16" CMU PIER ON 3' X 3' X 18" CONCRETE FOOTING WITH (3) 5/8" REBAR EACH WAY. (2) 5/8" VERTICAL RODS. FILL PIER W/ 3000 PSI GROUT. F5 16" X 16" CMU PIER ON 3' X 3' X 18" CONCRETE FOOTING WITH (3) 5/8" REBAR EACH WAY. (2) 5/8" VERTICAL RODS. FILL PIER W/ 3000 PSI GROUT. F6 8" X 16" CMU WALL W/5/8" VERTICAL REBAR IN EACH CORNER @32"O.C.. FILL CMU WALL WITH CONCRETE GOUT 2500 PS FILL WITH TREATED COMPACTED SOIL. 32" WIDE X 16" DEEP CONCRETE FOOTING WITH (3) 5/8" REBAR OVERLAP 40 X DIA. F7 DEPRESS SLAB AT SLIDING DOOR 1-3/4" TO ACCEPT DOOR SILL. SEE FLOOR PLAN FOR LOCATION OF SLIDING DOORS. F8 PROVIDE SOLID MASONRY STUCCO TRIM, SURROUND & PILASTERS NO QUIK-R, B-BOARD SHALL BE USED ON RESIDENCE. F9 ANY WOOD, PLYWOOD OR FIBROUS MATERIAL INSTALLED AGAINST A MASONRY SURFACE SHALL BE OF A PRESSURE TREATED NATURE. ANY MATERIAL INSTALLED BELOW FLOOD SHALL BE NON-SOLUBLE. NO EXCEPTIONS. F10 16" WIDE X 36" +/- DEEP 3,000 PSI MONOLITHIC CONC. FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING F11 NOT USED. F12 16" WIDE X 20" +/- DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING. F13 24" WIDE X 20" DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #4 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING. F14 20" WIDE X 20" DEEP, 3,000 PSI MONOLITHIC CONCRETE FOOTING W/ #5 BAR CONT. OVERLAP ENDS 40X DIA. MIN., EXTEND 6X6 #10/#10 W.W.M. FROM CONCRETE SLAB INTO FOOTING. BRICK VENEER OVER 8 X 8 X 8 CMU PIER FILLED SOLID F15 24" WIDE X 12" DEEP, 3,000 PSI MONOLITHIC CONCRETE GRADE BEAM W/ #5 BAR CONT. OVER LAP ENDS 40X D1 1 F10 F10 F10 F10 F10 F10 F10 F10 F15 F15 F15 ATTACHMENT 7 Page 22 Section VII. Item #1. L AV 15' x 35' POOL RAMP FILTER 24" AQUACAL SQ166R HEAT/COOL PUM P 23.8 UP DW OVEN PHONE CABLE 65' - 5 1/2" 36' - 0" 16' - 4 1/4" 15' - 0"34' - 1 1/4" 2' - 11" 3' - 9 1/2"3' - 0" 7' - 0" 16' - 0" 8' - 6 13/16" 17' - 10 1/2" 8' - 1 3/16" 9' - 4 1/4" 5' - 10" 9' - 4 1/2" 11' - 5 1/4" 6' - 5" 14' - 10" 14' - 9" 18' - 0 1/2" 5' - 3" 5' - 4" 7' - 2" 2' - 8" 5' - 7 1/4" JOYOUS TWO PERSON SAUNA 1' - 2" 3' - 1" 1' - 2" 30" x 60" 1' - 10 1/2" 1' - 2" 4' - 8" 1' - 2" 7' - 1" 9" 14' - 11" 65' - 5 1/2" 7' - 1" ROBINS ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LNDRY/ENTRY TILE FLR. 10' 1 1/8" CLG. HT. M. CLST WOOD FLR. 10'-1 1/8" CLG. HT. M. BATH TILE FLR. 10'-1 1/8" CLG. HT. MASTER BEDROOM WOOD FLR. 10'-1 1 /8" CLG. HT. PWDR WOOD FLR. 10'-1 1/8" CLG. HT. PANTRY WOOD FLR. 10'-1 1/8" CLG. HT. HALL WOOD FLR. 10'-1 1/8" CLG. HT. KITCHEN WOOD FLR. 10'-1 1/8" CLG. HT. D. ROOM WOOD FLR. 10'-1 1/8" CLG. HT. L. ROOM WOOD-FLR. 10'-1 1/8" CLG. HT. VANITY AREA 10' - 0" 2' - 10" 8' - 8" 36' - 0" 4' - 2" 2' - 2 1/2" DESK 5' - 8 3/4" 6' - 5" 5' - 8 3/4" 5' - 8 1/2"6' - 3"2' - 10 1/4" BATH #2 TILE FLR. 10' 1 1/8" CLG. HT. CLOSET WOOD FLR. 10' 1 1/8" CLG. HT. SAFE ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LOW AREA UNDER LANDING LIN. 4' - 1 1/4" 3' - 4 3/4" FRONT PORCH T&G FLR. SIDE PORCH T&G P.T. FLR. 17' - 10 1/2" 3' - 10 1/4" 10' - 8 1/4" 5' - 1 3/4" 5' - 1" 4' - 6 1/4" 2' - 6" 7' - 10 3/4" 3' - 11 1/2"9' - 0 1/2" 5' - 11 1/2" 11' - 0 1/2" 6' - 1" 4' - 0 7/8" 4" 4" 4' - 0" 3' - 0 21/32" meter head trash recept. at garage 7' - 5 1/2" 7' - 5 1/2" 3 A4.1 2 A4.1 2 A4.3 3' - 6" 3' - 6 1/16" 8' - 11 1/4" 8' - 11 1/4" 1 A4.1 7' - 8" 3' - 8" 8 5/8" W/D STACK 2' - 8 1/2" 10' - 10" 9' - 1 1/2" 9' - 4 7/16" 2' - 11" 10' - 3 9/16" 7' - 8" 9' - 8" 2' - 10 1/2" 5' - 10 1/4"12' - 1 3/4"12' - 2"5' - 10" 1' - 0 1/2" 9" 3"3" 3' - 10 1/2"7' - 4 3/4"6' - 4"10' - 8" 8' - 0" 8' - 0" 8' - 6 13/16" 4' - 5 17/32" 4' - 5 3/4" 4' - 5 3/4" 4' - 5 15/32" 4' - 2 3/4" 3' - 10 7/16" 7' - 5 1/2" 7' - 5 1/2" 2' - 10" 9' - 10" F F F C C CC BCCC CC CC 4 5 19 18 15 16 17 14 13213 1211 10 8 9 7 6 open door 3/0 X 6/0 WOOD GATE 3/0 X 6/0 WOOD GATE 10A 1ST FL 26.00' NAVD88 FP 25.917' NAVD88 RP 25.917' NAVD88 SY 23.4' NAVD88 FP 25.917' NAVD88 1 A4.2 2 A4.2 TEMPERED GLASS 5 1/2" 3 A4.4 A4.4 4 4 A4.1 BRICK HEARTH 3' - 4 1/2" 2' - 0" 2' - 8 1/2" 1' - 2" 4' - 8" 1' - 2" 4' - 9" EXISTING CARRIAGE HOUSE 5 A4.4 RAMP DOWN G 7' - 8 3/4" 6 1/4" 6 1/4" 4' - 8" 5 A4.1 GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE 20121 I.R.C. (INTERNATIONAL RESIDENTIAL CODE), WITH SOUTH CAROLINA AMENDMENTS, IECC 2009 ENERGY CODE AND ICC 600 HIGH WIND CONSTRUCTION 2. PROVIDE HURRICE CLIPS AT ALL RAFTERS AND JOISTS. AT ALL EXTERIOR DECK FLOOR JOISTS PROVIDE GALVANIZED HURRICANE CLIPS. 3. ALL PLUMBING WORK SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES INCLUDING THE CURRENT EDITION OF THE STANDARD PLUMBING CODE. USE WATER EFFICIENT FIXTURES AND LOCATE HOT WATER HEATERS CLOSE TO LARGE USAGE FIXTURES TO MINIMIZE LOADING. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH LOCAL OR PRIVATE UTILITY COMPANIES OR AGENCIES FOR RELOCATION OF, OR CONNECTION TO EXISTING UTILITIES. 5. THE TOP HEAD OF EXTERIOR DOORS AND WINDOWS TO BE AT THE SAME HEIGHT ABOVE THE FINISH FLOOR U.N.O. 6. ALL EXTERIOR WALLS ARE 2x6, U.N.O. 7. ALL INTERIOR WALLS ARE 2x4, EXCEPT WHERE NOTED. 8. ANY MATERIAL IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 9. ALL MATERIAL BELOW FLOOD SHALL BE NON-SOLUBLE MATERIAL. 10. CONTRACTOR AND SUBS SHALL REVIEW PLANS PRIOR TO CONSTRUCTION. CONTACT DESIGNER IF QUESTIONS ARISE BEFORE BUILDING. 11. PROVIDE INSULATION BEHIND ALL TUBS. INSTALL WITH NO VOIDS. 12. 5/8" TYP "WR & X" AT CLG OF GARAGE DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A2.1 1/4" = 1'-0"1 FIRST LEVEL F.F. ATTACHMENT 7 Page 23 Section VII. Item #1. UP - --- - --- - --- - --- 2 3/4" 2 3/4" 2 3/4"2 3/4" PROVIDE EGRESS WINDOWS PROVIDE EGRESS WINDOWS 1' - 11"1' - 11" 3 5/8" 1 7/8" - --- 3 A4.1 2 A4.12 A4.3 1 A4.1 4' - 9" DDD EEE E E E 4' - 9 9/16" 3' - 10 1/4" 12' - 9 7/16" 2' - 3 3/4" 2' - 11" 2' - 11" 2' - 3 3/4" 13' - 10 9/16" 12' - 10" 21 20 22 A 1 A4.2 2 A4.2 TEMPERED GLASS 4 A4.1 - --- 5 A4.1 GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE 20121 I.R.C. (INTERNATIONAL RESIDENTIAL CODE), WITH SOUTH CAROLINA AMENDMENTS, IECC 2009 ENERGY CODE AND ICC 600 HIGH WIND CONSTRUCTION 2. PROVIDE HURRICE CLIPS AT ALL RAFTERS AND JOISTS. AT ALL EXTERIOR DECK FLOOR JOISTS PROVIDE GALVANIZED HURRICANE CLIPS. 3. ALL PLUMBING WORK SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES INCLUDING THE CURRENT EDITION OF THE STANDARD PLUMBING CODE. USE WATER EFFICIENT FIXTURES AND LOCATE HOT WATER HEATERS CLOSE TO LARGE USAGE FIXTURES TO MINIMIZE LOADING. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH LOCAL OR PRIVATE UTILITY COMPANIES OR AGENCIES FOR RELOCATION OF, OR CONNECTION TO EXISTING UTILITIES. 5. THE TOP HEAD OF EXTERIOR DOORS AND WINDOWS TO BE AT THE SAME HEIGHT ABOVE THE FINISH FLOOR U.N.O. 6. ALL EXTERIOR WALLS ARE 2x6, U.N.O. 7. ALL INTERIOR WALLS ARE 2x4, EXCEPT WHERE NOTED. 8. ANY MATERIAL IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 9. ALL MATERIAL BELOW FLOOD SHALL BE NON-SOLUBLE MATERIAL. 10. CONTRACTOR AND SUBS SHALL REVIEW PLANS PRIOR TO CONSTRUCTION. CONTACT DESIGNER IF QUESTIONS ARISE BEFORE BUILDING. 11. PROVIDE INSULATION BEHIND ALL TUBS. INSTALL WITH NO VOIDS. 12. 5/8" TYP "WR & X" AT CLG OF GARAGE DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A2.2 1/4" = 1'-0"1 SECOND FLOOR F.F. ATTACHMENT 7 Page 24 Section VII. Item #1. 1' - 2 1/4" 1' - 2 1/4" 1' - 2 1/4" 12 1/8" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 3 1/4" / 12" 3 1/4" / 12" 3" / 12" 3" / 12" 3" / 12" 10" / 12" 10" / 12" 3" / 12"3" / 12" 10" / 12" 10" / 12" 3" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" RIDGE RIDGERIDGE RIDGE RIDGE RIDGE RIDGE ROOF BREAK V ALLEY V ALLEY V ALLEY V ALLEY ROOF KICK OUT ROOF KICK OUT ROOF BREAK ROOF BREAK ROOF BREAK ROOF BREAK ROOF BREAKROOF BREAK ROOF BREAK ROOF BREAKROOF BREAKROOF BREAK 5 1/2" 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2 X 8 RAFTERS 16" O.C. 2' - 8" 3' - 4" 8 1/2" DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A2.3 NOTE: ALL RIDGES ARE TO BE CONTINUOUS MEMBERS WHERE POSSI BLE USING AVAILABLE STANDARD LUMBER SIZES 1/4" = 1'-0"1 ROOF PLAN ATTACHMENT 7 Page 25 Section VII. Item #1. FLASHING NOTES: 1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METAL S TO PREVENT GALVANIC REACTION. 2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL WINDOWS AND DOORS. 3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING CODE. HARDIE HORIZONTAL PLANK SIDING FIBERGLASS ARCHITECTURAL SHINGLES TABBY STUCCO 5V METAL ROOF LEGENDROOFWALL FIRST LEVEL F.F. FIRST LEVEL F.F. SECOND FLOOR F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. APPROXIMATE LINE OF FINISH GRADE SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT. 9' - 1 1/8"10' - 1 1/8" 1' - 4 3/4" 5' - 8 3/4"6' - 5"5' - 8 3/4" 24' - 5 31/32" LIVING PLANT WALL BOARD & BATT SIDING P.T. WOOD 36" HT. RAILING 10" SQ. LOW COUNTRY COLUMN 1X4 & 1X8 HARDIE FASCIA, TYP. SLOPED 2X4 ON 1X8 WATERTABLE 2X8 JOIST TRELLIS REFER TO /1 A4.3TABBY STUCCO ON FOUNDATION WALL TABBY STUCCO TABBY STUCCO GOTHIC CHIMNEY CAP 18"X36" DECORATIVE WOOD GABLE VENT 12 x10 BEAM HARDIE TRIM 5/4X8,BEVELED TOP EDGE 10 x 12 BEAM BOARD & BATT SIDING 10" SQ. COLUMN FOOTINGS W/ BRICK FACADE 12" 12" 3" 12" 3 1/4" 12" 3" / 12" 10" / 12" 7" / 12" 9' - 2 7/8" 2 A4.3 1 A4.1 4' - 0" --- -1 A4.2 3'-2" A4.4 2 3 A4.4 4 A4.1 36" HT HANDRAIL PER CODE - --- 4 1/2 " 4 1/2 " 12 " / 12" 12 " / 12" 12 " / 12" 12 " / 12" CLCL 4' - 0" 9' - 1 1/8"1' - 4 3/4"10' - 1 1/8" 8' - 0" 11' - 9 3/4" 8' - 0" 1ST FL 26.00' NAVD88 1ST FL 26.00' NAVD88 AVER. ADJ. SIDEWALK GRADE = 22.96' 3' - 4 27/32" PORCH ELEV 25.917 2' - 6" GRADE 23.00 STANDING SEAM METAL ROOFING F A E E E F F3 1 2 1' - 6" 3'-0" 1' - 6" 3'-0" 5 A4.1 FIRST LEVEL F.F. FIRST LEVEL F.F. SECOND FLOOR F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT. 1ST FL NAVD88 GAR NAVD88 1ST FL NAVD88 GAR NAVD88 APPROXIMATE LINE OF FINISH GRADE 12" SQ. COLUMN FOOTINGS W/ BRICK FACADE 12" SQ. COLUMN FOOTINGS W/ BRICK FACADE TABBY STUCCO ON FOUNDATION WALL TABBY STUCCO METAL CHIMNEY CAP 18"X36" DECORATIVE WOOD GABLE VENT 18"X36" DECORATIVE WOOD GABLE VENT WWNDW HD. HT. 8' - 0" 10' - 1" 1X4 & 1X8 HARDIE FASCIA, TYP. 5/4X6 HARDIE FRIEZE BOARD, TYP. STANDING SEAM METAL ROOFING 10" SQ. LOW COUNTRY COLUMN <varies> SLOPED 2X4 ON 1X8 WATERTABLE WNDW. HD. HT. 7' - 0" 7" / 12" 10" / 12" 10" / 12" 7" / 12" 3" / 12" 3 1/4" 12" 3" 12" 12" 12" 4' - 0" 1' - 9" 3' - 1" 4' - 0" --- -1 A5.2 A4.4 1 2' - 8" HARDIE PLANK BOARD AND BATTEN 12" O.C. 1 X 4 HARDIE PLANK FASCIA 1 X 8 HARDIE PLANK FASCIA PREFINISHED ROOF METAL EDGING 8" X 8" LOW COUNTRY COLUMN C C B C C C C C EEE 10' - 1 1/8" 1' - 4 3/4" 9' - 1 1/8" DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A3.1 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION ATTACHMENT 7 Page 26 Section VII. Item #1. FLASHING NOTES: 1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METAL S TO PREVENT GALVANIC REACTION. 2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL WINDOWS AND DOORS. 3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING CODE. FIRST LEVEL F.F. FIRST LEVEL F.F. SECOND FLOOR F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT. STANDING SEAM METAL ROOFINGSTANDING SEAM METAL ROOFING HOG BOARD UNDERPENNING TABBY STUCCO MASONRY CHIMNEY CAP 10" SQ. LOW COUNTRY COLUMN P.T. 36" HT. WOOD RAILING APPROXIMATE LINE OF FINISH GRADE 12" SQ. COLUMN FOOTINGS W/ BRICK FACADE 10' - 1" 1X4 & 1X8 HARDIE FASCIA, TYP. 5/4X6 HARDIE FRIEZE BOARD, TYP. 3 1/4" / 12" 3" 12" 3" 12" 10" 12" 10' - 1" 10' - 1" 6 1/2" 2' - 11" 2' - 10" 4' - 10" 5' - 0" 2' - 10" 4' - 4" 4' - 4" 2' - 10" 4' - 11 3/4" 4' - 10 1/4" 1ST FL 26.00' NAVD88 1ST FL 26.00' NAVD88 4 1/2" HARDIE PLANK BOARD AND BATTEN 12" O.C. 1 X 4 HARDIE PLANK FASCIA 1 X 8 HARDIE PLANK FASCIA 1 X 4 HARDIE PLANK FASCIA 1 X 8 HARDIE PLANK FASCIA PREFINISHED ROOF METAL EDGING 6' - 0 1/2" --- -1 A4.4 9' - 1 1/8"1' - 4 3/4"10' - 1 1/8" 24' - 5 31/32" ROOF HT FIRST LEVEL F.F. FIRST LEVEL F.F. SECOND FLOOR F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT. APPROXIMATE LINE OF FINISH GRADE SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT. TABBY STUCCO ON FOUNDATION WALL TABBY STUCCO 12" SQ. COLUMN FOOTINGS W/ BRICK FACADE P.T. WOOD 36" HT. RAILING SLOPED 2X4 ON 1X8 WATERTABLE STANDING SEAM METAL ROOFING1X4 & 1X8 HARDIE FASCIA, TYP. 5/4X6 HARDIE FRIEZE BOARD, TYP. 3" 12" 10" 12" 3" 12" 2 A4.2 A4.3 3 TABBY STUCCO GOTHIC CHIMNEY CAP 9' - 3 1/8" 12 " / 12" 12 " / 12" 5 A4.4 3' - 4" 4 1/2" 4 1/2" 4 1/2" HARDIE PLANK BOARD AND BATTEN 12" O.C. 1 X 4 HARDIE PLANK FASCIA 1 X 8 HARDIE PLANK FASCIA PREFINISHED ROOF METAL EDGING --- -1 A4.4 HARDIE PLANK BOARD AND BATTEN 12" O.C.C 5 C G 9' - 1 1/8"1' - 4 3/4"10' - 1 1/8" 1ST FL 26.00' NAVD88 1ST FL 26.00' NAVD88 8" 8" X 8" LOW COUNTRY COLUMN DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A3.2 1/4" = 1'-0"1 RIGHT ELEVATION 1/4" = 1'-0"2 LEFT ELEVATION ATTACHMENT 7 Page 27 Section VII. Item #1. DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A3.3 1 3D FRONT VIEW 12 3D FRONT VIEW 2 3 3D REAR VIEW 14 3D REAR VIEW 2 ATTACHMENT 7 Page 28 Section VII. Item #1. FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. ROOF PLAN SECOND FLOOR PLATE HT. 1' - 4 3/4" 9' - 1 1/8" 9' - 2 7/8" 4 5/8" 1' - 4 3/4" 9' - 9 21/32" DINING ROOM TO KITCHEN DOOR TO ATTIC AT FRONT UPSTAIRS LOFT UNFINISHED 3 " / 12" 1 0" / 12" 3 " / 12" 1 0" / 12" A4.1 4 1ST FL 26.00' NAVD88 1"PORCH ELEV 25.917 2' - 6" AVER. ADJ. SIDEWALK GRADE = 22.96'2' - 11 15/32" 36" HT PT HANDRAIL -1.25" X 1.25" PT PICKETS (2)5/4 X 6 PT TREADS/1 X PT RISERS/2 X 12 CARRIAGES 1X8 HARDIE PLANK SHEET WITH 1 X 3 HP BATTEN STRIP @16" O.C. STANDING SEAM METAL ROOFING FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. 10' - 1" 10' - 1 1/8" 3 1/4" / 12" NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE SIMPSON HOLDDOWN CORNERS AS REQUIRED LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 4 S4S HARDIE TRIM + BLOCKING 1 X 6 BEADED #1 SYP SOFFIT PANEL 2X8 SUB FASCIA 1 X 6 S4S HARDIE TRIM + BLOCKING 30 YR. ARCHITECTURAL FIBERGLASS ASPHALT ROOF SHINGLE OR APPROVED EQUAL 15# ASPH. ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @ 16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO ASTM-D 7158-07 "H" SHINGLES. 2X6 CJ OR AS NOTED @ 16" O.C. 2 X 6 WD. P.T. MUD SILL SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS. ALL STRAPPING DESIGN BY ENGINEER ANY WOOD TOUCHING CONCRETE OR BELOW FLOOD SHALL BE PRESSURE TREATED (PT) APPROXIMATE LINE OF FINISHED GRADE. GRADE AWAY FROM HOUSE CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. RAFTER BEARING OVER HANG 5/4" X 6" PT DECKING 2 X 8 PT FLR JST @ 16" O.C. W/ JOIST HANGER 4" BRICK VENEER PIER WITH CMU CENTER 7 1/4" 1 X 8 S4S HARDIE TRIM + BLOCKING 16" 1" 10' - 10 1/4" TOP OF COLUMN 1 X 6 BEADED #1 SYP SOFFIT PANEL 2' - 11 15/32" 1ST FL 26.00' NAVD88 AVER. ADJ. SIDEWALK GRADE = 22.96' PORCH ELEV 25.917 FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. 8" 12 " / 12" NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE 1 X 4 S4S HARDIE TRIM + BLOCKING 2X8 SUB FASCIA 1 X 6 S4S HARDIE TRIM + BLOCKING 2X6 CJ OR AS NOTED @ 16" O.C. SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS.ALL STRAPPING DESIGN BY ENGINEER ANY WOOD TOUCHING CONCRETE OR BELOW FLOOD SHALL BE PRESSURE TREATED (PT) APPROXIMATE LINE OF FINISHED GRADE. GRADE AWAY FROM HOUSE CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. OVER HANG 1 X 8 S4S HARDIE TRIM + BLOCKING 1'-0" 2" 9' - 3 1/8" (3) 2 X 12 #2 SYP W/ 1/2 PLYWOOD BOX BEAM 1/2" HARDIE PLANK PANELS 2 X 6 PLATE CONT. 2 X6 LEDGER 1 X 6 HARDIE TRTIM FREIZE ROOF BEYOND --- -2 A4.1 1 X 6 BEADED #1 SYP SOFFIT PANEL 1 X 6 BEADED #1 SYP SOFFIT PANEL 10' - 1 1/8" 10' - 1 1/8" 1' - 4 3/4" FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. 1' - 4 3/4" 10' - 1 1/8" 1 0" / 12" NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE SIMPSON HOLDDOWN CORNERS AS REQUIRED LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 4 S4S HARDIE TRIM + BLOCKING 2X8 SUB FASCIA 1 X 6 S4S HARDIE TRIM + BLOCKING 30 YR. ARCHITECTURAL FIBERGLASS ASPHALT ROOF SHINGLE OR APPROVED EQUAL 15# ASPH. ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @ 16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO ASTM-D 7158-07 "H" SHINGLES. 16" TJI @ CJ OR AS NOTED @ 16" O.C. SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS. ALL STRAPPING DESIGN BY ENGINEER ANY WOOD TOUCHING CONCRETE OR BELOW FLOOD SHALL BE PRESSURE TREATED (PT) APPROXIMATE LINE OF FINISHED GRADE. GRADE AWAY FROM HOUSE CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. OVER HANG 5/4" X 6" PT DECKING 2 X 8 PT FLR JST @ 16" O.C. W/ JOIST HANGER 1 X 8 S4S HARDIE TRIM + BLOCKING --- -2 A4.1 2'-0" R19 BATT INSULATION 3/4" ADVANTECH UNDERLAYMENT SCREWED AND GLUED (3) 2 X 12 #2 SYP W/ 1/2 PLYWOOD BOX BEAM 1ST FL 26.00' NAVD88 1 X 6 BEADED #1 SYP SOFFIT PANEL 1 X 6 BEADED #1 SYP CEILING 10' - 1 1/8" FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. SECOND FLOOR PLATE HT. 1ST FL 26.00' NAVD88 1" 9' - 1 1/8"1' - 4 3/4"10' - 1 1/8" A4.1 4 SimA4.2 1 Sim DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A4.1 1/4" = 1'-0"1 BUILDING CROSS SECTION1 3/4" = 1'-0"2 FRONT PORCH SECTION 3/4" = 1'-0"3 LEFT SIDE PORCH 3/4" = 1'-0"4 LIVING ROOM PORCH 1/4" = 1'-0"5 ELEVATION/SECTION OF LEFT WING AT FRONT PORCH ATTACHMENT 7 Page 29 Section VII. Item #1. 5/8" rebar 5/8" rebar FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. GARAGE LEVEL F.F. NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE 12 " / 12" SIMPSON HOLDDOWN CORNERS AS REQUIRED LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S HARDIE FASCIA CONT. 1 X 4 S4S HARDIE TRIM + BLOCKING 2X8 SUB FASCIA 1 X 6 S4S HARDIE TRIM + BLOCKING 30 YR. ARCHITECTURAL FIBERGLASS ASPHALT ROOF SHINGLE OR APPROVED EQUAL 15# ASPH. ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @ 16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO ASTM-D 7158-07 "H" SHINGLES. R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. R19 OPEN CELL FOAM @ RAFTER DECK 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1X8 HARDIE PLANK SHEET WITH 1 X 3 HP BATTEN STRIP @16" O.C. 1/2" GYP. BOARD 2X10 CJ OR AS NOTED @ 16" O.C. 2 X 6 WD. P.T. BOTTOM PLATE CONT. ALL STRAPPING DESIGN BY ENGINEER CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. SEE SECTIONS FOR RAFTER BEARINGS SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION. ATTACH IN STRICT COMPLIANCE W/ MANUFACTURER & ENGINEERS SPECIFICATIONS. 4" THICK, 3000 P.S.I. CONCRETE SLAB REINF. W/ 6x6 #10/#10 W.W.M. OR FIBERGLASS ON CLEAN, DRY, TREATED, TERMITE COMPACTED EARTH FILL 2X6 PURLINS-CUT BETWEEN WOOD STUDS 48" O.C. FOR PLYWOOD SHEATHING REQUIREMENTS. ALL STRAPPING DESIGN BY ENGINEER ANY WOOD TOUCHING CONCRETE OR BELOW FLOOD SHALL BE PRESSURE TREATED (PT) APPROXIMATE LINE OF FINISHED GRADE. GRADE AWAY FROM HOUSE CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPLIER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1/2" EXTERIOR SHEATHING FIRST COURSE TRTD 1X8 HARDIE PLANK SHEET WITH 1 X 3 HP BATTEN STRIP @16" O.C. COPPER METAL DRIP ON CHAMFERED 2X & 1X 8 TRIM BOARD CONT. MECHANICALLY FASTENED TO FOUNDATION 4" see struc' dwgs 1' - 4" 1' - 9" 2' - 0" 13' - 0 1/4" RAFTER BEARING 10' - 1 1/8" 1' - 4 3/4" 10" 1 SHEET 3/4 PLYWOOD AT GABLE END2' - 1" OVER HANG A4.2 3 3 1/4" 3 0.00° 5 11/16" 1 X 6 BEADED #1 SYP SOFFIT PANEL FIRST LEVEL F.F. FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. 11' - 5 7/8" 10' - 1 1/8" RAFTER BEARING 12 " / 12"--- -1 A4.2 SIM. --- - NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE 1 A4.2 SIM. FIRST LEVEL F.F. COPPER METAL DRIP ON CHAMFERED 2X & 1X 8 TRIM BOARD CONT. MECHANICALLY FASTENED TO FOUNDATION 3 0.00° 1 3/4" 1" 5/4 X 8 PT MECHANICALLY FASTENED TO FOUNDTAION Level 27 DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A4.2 NOTES: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) W IND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IRC 20 121 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODE S. CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPL IER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. ALL STRAPPING DESIGN BY ENGINEER. 3/4" = 1'-0"1 LAUNDRY ROOM WALL SECTION 3/4" = 1'-0"2 MASTER BATH WALL SECTION 2 3" = 1'-0"3 TYPICAL WATER TABLE ATTACHMENT 7 Page 30 Section VII. Item #1. 5/8" rebar FIRST LEVEL F.F. 5' - 0" FIRST LEVEL F.F. SECOND FLOOR F.F. FIRST LEVEL PLATE HT. GARAGE LEVEL F.F. SECOND FLOOR PLATE HT. 9' - 1 1/8" 7' - 2 31/32" 8' - 0" 7 1/4" 1' - 8 3/4" closet @ stairs 7' - 8 29/32" 9' - 1 1/8" LIVING PLANT WALL SEE SPEC SHEET- A4.3 13' - 1 1/8" 4' - 0 1/2" RAFTER BEARING @ STAIRCASE NOTE: 1) RAFTER NOTCH NOT TO EXCEED 25% 2) FIRE CUT NOT TO EXCEED 1/3 OF RAFTER PER CODE SIMPSON HOLDDOWN CORNERS AS REQUIRED LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE 1 X 8 S4S HARDIE FASCIA CONT. 1 X 4 S4S HARDIE TRIM + BLOCKING 2X8 SUB FASCIA 1 X 6 S4S TRIM + BLOCKING 30 YR. ARCHITECTURAL FIBERGLASS ASPHALT ROOF SHINGLE OR APPROVED EQUAL 15# ASPH. ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @ 16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO ASTM-D 7158-07 "H" SHINGLES. R19 OPEN CELL FOAM @ RAFTER DECK APPROXIMATE LINE OF FINISHED GRADE. GRADE AWAY FROM HOUSE R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C. 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1/2" EXTERIOR SHEATHING FIRST COURSE TRTD 1X8 HARDIE PLANK SHEET WITH 1 X 3 HP BATTEN STRIP @16" O.C. METAL DRIP ON CHAMFERED 2X & 1X10 TRIM BOARD CONT. MECHANICALLY FASTENED TO FOUNDATION 3 " / 12" 1 0" / 12" TEMPERED WINDOW AS SPECIFIED HANDRAIL AT 36" HT ABOVE TREADS PER CODE 7 1/4" 5/8" TYPE X GYPSUM WOOD STAIRS PER CODE UP UP WOOD OVER LANDING 4' - 11 25/32" 10' - 1 1/8" 1' - 4 3/4"2' - 0" Level 25 Level 27 1 X 6 BEADED #1 SYP SOFFIT PANEL 7 1/4" 8' - 4 11/32" 1/2" GYPSUM ROOF PLAN 3' - 4" 6" 1" 2 5/16" 6" 1/16" 4'-0" GOTHIC ARCH MASONRY CHIMNEY CAP NARROW SIDE 2'-8" CHIMNEY TERMINATION CAP(BY MANUFACTURER) MASONRY WASH 3/4" X 6" TABBY STUCCO TRIM7 11/32" 8 21/32" DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ Designer Author 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A4.3 NOTES: ALL STRUCTURAL MEMBERS & ANY EXTERIOR MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) W IND LOAD & MEET OR EXCEED ALL BUILDIING CODES INCLUDING IRC 20 21 W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODE S. CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPL IER AND REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND INSTALLATION. ALL STRAPPING DESIGN BY ENGINEER. 3/4" = 1'-0"1 TRELLIS DETAIL 3/4" = 1'-0"2 STAIR SECTION 3/4" = 1'-0"3 MASONRY TABBY STUCCO CHIMNEY CAP ATTACHMENT 7 Page 31 Section VII. Item #1. ELEVATION PLAN SECTION OPTIONAL 2X6" CAP 2"X6" PRESSURE TREATED #2 VARIES 2X4" STRINGER 6"X6" POST 2X4" STRINGEROPTIONAL 2X6" CAP 6X6" POSTS SPACED 8' ON CENTER 8' SHADOWBOX FENCE SECTIONS VERTICAL FENCING 1"X6" PRESSURE TREATED #2 6"X6" PRESSURE TREATED PINE POSTS 2X4" STRINGER UNDER CAP FINISHED GRADE 3 - 2X4" PRESSURE TREATED STRINGERS 6" X 6" PRESSURE TREATED PINE #2 POST 6' - 0" CONCRETE FOOTING 4" 18"MIN VERTICAL FENCING 1"X6" PRESSURE TREATED #2 VERTICAL FENCING 1"X6" PRESSURE TREATED #2 FIRST LEVEL F.F. GARAGE LEVEL F.F. Level 27 FIRST LEVEL F.F. GARAGE LEVEL F.F. 2 X 6 PT TOP RAIL W/ 5/4 GRAB RAIL 3/4" 1.5" X 1.5" PT BALUSTERS 1 X 4 PT SIDE BOARD 1 X 4 PT SIDE BOARD 6 X 6 PT NEWEL OVER THE POST RAIL 2 X 12 PT CARRIAGE AND TREADS 12" X 12" X 12"CONCRETE FOOTING Level 27 FIRST LEVEL F.F. 2 X 6 PT TOP RAIL W/ 5/4 GRAB RAIL 1.5" X 1.5" PT BALUSTERS 1 X 4 PT SIDE BOARD 1 X 4 PT SIDE BOARD 2 X 6 BACK BOARD TO WALL Level 27 2 X 6 #2 SYP STUD WALL WITH R-19 BATT INSULATION 1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST SHEET TO BE P.T. 1" X 3" HARDIE PLANK BATTEN STRIP OVER 7/16" HARDIE PLANK SHEET MATERIAL 2 X 6 ENERGY CORNER 9 1/2" SIMPSON HOLD-DOWN PER STRUCTURAL ENGINEER FIRST LEVEL F.F. GARAGE LEVEL F.F. TOP OF POOL THICKNESS BY POOL CONTRACTOR 5' - 6" WATER LINE RAMP 1" 5'4 x 6 PT DECKING 1 X 3 PT EDGING 1 X 6 PT BAND 1 X 10 PT BAND 2 X 12 FLR JOISTS @@ 16" O.C. 1 X 4 PT BAND 2 X 4 PT TOP PLATE 2 X 4 VERTICAL FRAME 2 X 4 PT BOTTOM PLATE 1 X 6 PT HORIZONTAL BOARD 2 X PT BLOCKING 2 X PT BLOCKING BLACK GALV. HARDWARE CLOTH 1" 1" 2 X PT MUD SILL 1 X 4 PT BAND - --- Sim6A A4.4 SECTION 6A/A4.4 DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A4.4 3/4" = 1'-0"1 SERVICE YARD DETAILS 3/4" = 1'-0"2 STAIR-HANDRAIL DETAIL 3/4" = 1'-0"3 HANDRAIL SECTION 1 1/2" = 1'-0"4 TYPICAL CORNER SECTION 1/2" = 1'-0"5 POOL SECTION 3/4" = 1'-0"6 HOG BOARD UNDERPINNING DETAIL OLD WORLD TABBY PAVERS ATTACHMENT 7 Page 32 Section VII. Item #1. ALL WINDOW SIZES ARE NOMINAL. CONTRACTOR TO VERIFY ALL ROUGH OPENINGS. ALL GLASS TO BE LOW E GLASS. WINDOW SUPPLIER SHALL CONFORM TO ALL CODES DESIGNATED. TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CO DE. CONTACT DESIGNER IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL WINDOW S SHALL MEET THE ENERGY STAR GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE NOTE ALL DOOR SIZES ARE NOMINAL. CONTRACTOR TO VERIFY RO UGH OPENINGS. ALL GLASS TO BE LOW E GLASS. DOOR SUPPLIER SHALL CO NFORM TO ALL CODES DESIGNATED. TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CO DE. CONTACT DESIGNER IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL DOORS SHALL MEET THE ENERGY STAR GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE NOTE DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A5.0 WINDOW SCHEDULE SYM. Width Height Description DP RATING U-FACTOR SHGC A 2' - 7 1/2" 4' - 11 3/4" 3260 FIBERGLASS CLAD DBHG M ARVIN ELEVATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29 B 2' - 7 1/2" 4' - 3 3/4" 3252 FIBERGLASS DBHG MARVIN ELEVATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29 C 2' - 7 1/2" 5' - 7 3/4" 3268 FIBERGLASS DBHG MARVIN ELEVATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29 D 2' - 5 1/2" 3' - 11 3/4" 3048 FIBERGLASS DBHG MARVIN ELEVATE W/LOW E GLASS - SDL MUNTINS 40/45 .29 .29 E 2' - 8" 4' - 7 1/8" 3371 FIBERGLASS CSMT MARVIN ELEV ATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29 F 2' - 11 1/2" 5' - 0" 3252 FIBERGLASS DBHG MARVIN ELE VATE W/LOW E GLASS - SDL MUNTINS 40/45 .29 .29 G 2' - 0" 3' - 11 1/8" 2547 FIBERGLASS CSMT MARVIN ELE VATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29 DOOR SCHEDULE Tag Number Door Size Door Type DESCRIPTION DP RATING U-FACTOR SHGC Width HeightThickness 1 5' - 11" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN PR 3/0 FR DOOR W/ SDL AND LOW E GLASS 40/45 .29 .29 2 2' - 0" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN FR DO OR W/ SDL AND LOW E GLASS 40/45 .29 .29 3 2' - 0" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN FR DO OR W/ SDL AND LOW E GLASS 40/45 .29 .29 4 3' - 0" 8' - 0" 1 3/4" 3/4 GLASS OVER SINGLE PANEL MA HOGANY DOOR- SDL LOWE GLASS 40/45 .29 .29 5 2' - 8" 8' - 0" 1 3/4" 6 PANEL FIBERGLASS DOOR EXTERI OR DOOR UNIT 40/45 .29 .29 6 2' - 8" 8' - 0" 1 3/4" 6 PANEL METAL DOOR UNIT REINFO RCE FRAME 7 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT 8 2' - 0" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 9 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 10 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 10A 3' - 0" 8' - 0" 0" CASED OPENING 11 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 12 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 13 3' - 0" 8' - 0" 0" CASED OPENING 14 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT 15 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 16 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 17 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT 18 2' - 0" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 19 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT 20 2' - 8" 5' - 0" 1 3/8" 4 PANEL MDF SOLID CORE UNIT C UT DOWN 21 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE UNIT 22 2' - 8" 5' - 0" 1 3/8" 4 PANEL MDF SOLID CORE UNIT C UT DOWN WINDOWS ARE MARVIN ELEVATE ATTACHMENT 7 Page 33 Section VII. Item #1. DOUBLE HUNG WINDOW AS SPEC'D 1/2" GYPSUM BOARD 1/4" SHIM SPACE (3) 2X6 2X6 STUD WALL W/ R-19 INSULATION 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC 600 HIGH WIND STANDARDS 5/4 X 6 S4S HARDIE PLANK EDGE OF SILL BELOW 1C A5.1 SILL SCALE: 3" = 1'-0" 1B A5.1 MEETING RAIL SCALE: 3" = 1'-0" 1A A5.1 HEAD SCALE: 3" = 1'-0" 1D A5.1 JAMB SCALE: 3" = 1'-0" 1/4" MARGIN (TYP) 1/4" MARGIN (TYP) SHUTTER T&G V JT (1/2 WIDTH OF WINDOW STAINLESS STEEL SHUTTER DOG HINGE W/ BLACK POWDER COAT FINISH 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC-600 HIGH WIND STANDARDS 2X6 STUD WALL W/ R-19 INSULATION 1/2" GYPSUM BOARD HEADER AS SPEC'D PRE-FINISHED ALUM. FLASHING 1/4" SHIM SPACE BACKER ROD & CAULK DOUBLE HUNG WINDOW AS SPEC'D 1/4" MARGIN (TYP) DOUBLE HUNG WINDOW AS SPEC'D 1/4" SHIM SPACE BACKER ROD & CAULK 3X2 S4S (EXACT SIZE) #1 P.T. DURAPINE SILL PRE-FINISHED ALUM. FLASHING (2) 2X6 CONT. 1/2" GYPSUM BOARD 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC & ICC-600 HIGH WIND STANDARDS 2 3/4" 1/4" 3" 2X6 STUD WALL W/ R-19 INSULATION 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL SILICONE SEALANT 3/4" CAP RB 60 CROWN MOLDING 1 X 3-1/2 S4S TRIM RB 273 PICTURE MOLD 1X3 S4S TRIM BOARD 1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE 5/4 X 6 S4S HARDIE W/ 5-1/2" EXPOSURE DOUBLE HUNG WINDOW DETAIL SCALE: 1"= 1'-0" 1 A5.1 1C A5.1 1B A5.1 1D A5.1 1A A5.1 1 1/2"5 1/2" SEE WINDOW SCHEDULE WINDOW HEIGHT3" WINDOW - SEE WINDOW SCHEDULE FOR MORE DETAILS 1 X 4 HARDIE PLANK TRIM 3 1/2"3 1/2" 3/4" 3/4" SEE WINDOW SCHEDULE WINDOW WIDTH DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI SAL 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A5.1 3" = 1'-0"2 WINDOW & SHUTTER DETAILS HARDIE SIDING- 3" SCALE 1" = 1'-0"1 WINDOW & SHUTTER DETAILS - 1" SCALE ATTACHMENT 7 Page 34 Section VII. Item #1. 2C A6.1 JAMB SCALE: 1-1/2" = 1'-0" 1/4" SHIM SPACE 5/4 X 4-9/16 S4S WOOD JAMB RB-34 MOLDING STOP CUSTOM WOOD ENTRY DOOR / SIDELIGHT 1/2" GYPSUM BOARD 2X6 STUD WALL W/ 5-1/2" R-19 BATT INSULATION 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC AND ICC 600 HIGH WIND STANDARDS 5/4 X 6 S4S WOOD #1 P.T. DURAPINE EDGE OF SILL BELOW (3) 2X6 A6.1 A6.1 CUSTOM WOOD ENTRY DOOR/SIDELIGHT RB-34 MOLDING STOP FACTORY SILL 3/4" T&G PLYWOOD 2A HEAD SCALE: 1-1/2" = 1'-0" 2B SILL SCALE: 1-1/2" = 1'-0" VERIFY R.O. W/ ENTRY DOOR MANF. 0' - 2 3/4" 0' - 0 3/8"0' - 2 3/8" 0' - 0 1/2" 0' - 2" 2C A6.1 MULL SCALE: 1-1/2" = 1'-0" 1/4" MARGIN (TYP) 1/4" MARGIN (TYP) HEADER AS SPEC'D PREFINISHED ALUM. FLASHING 1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE 5/4 X 6 S4S WOOD #1 P.T. DURAPINE OR AZEK W/ 5-1/2" EXPOSURE 1/4" SHIM SPACE 5/4 X 4-9/16 S4S WOOD JAMB RB-34 MOLDING STOP CUSTOM WOOD ENTRY DOOR / SIDELIGHT 1/4" MARGIN (TYP) 1X8 HARDIE SHEET WITH 1 X 3 HARDIE BATTEN STRIPS 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 2 x 8 PT FLOOR JOIST @16" O.C. 5 1/2" 1/4" SHIM SPACE 5/4 X 4-9/16 S4S WOOD JAMB RB-34 MOLDING STOP CUSTOM WOOD ENTRY DOOR / SIDELIGHT 1/2" GYPSUM BOARD 2X6 STUD WALL W/ 5-1/2" R-19 BATT INSULATION 1/2" OSB SHEATHING W/ "TYVEK" HOUSE WRAP ON ENTIRE EXTERIOR, NAIL SHEATHING ACCORDANCE W/ 2021 IRC AND ICC 600 HIGH WIND STANDARDS 5/4 X 6 S4S WOOD #1 P.T. DURAPINE EDGE OF SILL BELOW (3) 2X6 1/4" MARGIN (TYP) 1/4" MARGIN (TYP) 1X8 HARDIE HORIZONTAL PLANK SMOOTH CEMENTITOUS SIDING WITH 6-1/2" REVEAL 5 1/2" FIRST LEVEL F.F. - --- - --- - --- 2A A6.1 A6.1 A6.1 2B 2C 4" 2"6" 2"6"7' - 11 1/2" 4"2' - 0 5/32"6"5' - 11 5/16"6"2' - 0 1/32" 11' - 7 1/2" 213 HARDIE PLANK OR AZEK 3/4" X 4" TRIM HARDIE PLANK OR AZEK 5/4" X 6" TRIM HARDIE PLANK OR AZEK 2" X 2" TRIM W/ BEVEL EDGE CONCEALED METAL FLASHING SIDING AS SPECIFIED HARDIE PLANK OR AZEK 3/4" X 6 MULLION 1" 1" 4 A4.1 Level 27 5 A4.1 DESIGN FOR Certified Professional Building Designer A B D ® Professional Member of American Institute of Building Design SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT 23 Plantation Park Drive Bldg 100 -Suite 103 Bluffton SC 29910 Ph. 843.815.9575 Certified Green Professional COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION OR OBSERVATION MANAGEMENT 06.04.2024 08.05.2024 12.09.2025 05.06.2026 FINAL-SUBMITTAL INITIALS OWNERS _______ BUILDER________ S. LIBERTI MAB 24-033 05.01.2024GLENDA AND BILLY MIKULAK LOT#2 X 2A " GREEN STREET" BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA A6.1 3/4" = 1'-0"2 FRONT DOOR ELEVATION ATTACHMENT 7 Page 35 Section VII. Item #1. OF 4 SHEET 1 Chk'd By: Project ID: Issue / Revision DescriptionNo. Drawn Date: Chk'd By: Project ID: Sheet No. M. Brock po box 358, port royal south carolina, 29935 ph. 843.540.6407 mbrock@mbrockdesigns.com J. M. BROCK RLA copyright © M. Brock, RLA all rights reserved tS-101 Title Page E E Drawn By: Drawn By:M. Brock 1 25004 Site Development Plans For Mikulak Residence 95 Green St. Bluffton, SC 10.08.25 2 SUBMITTAL 12/25 PROJECT NOTES: Owner: Glenda Mikulak Property Address: 95 Green St. Property Lot Number: 2A Tax ID Number: R610 039 00A 0347 0000 Property Area: 0.334 Acres FLAT-BOTTOM TRENCH DETAILV-SHAPED TRENCH DETAIL SILT FENCE INSTALLATION South Carolina Department of Health and Environmental Control South Carolina Department of Health and Environmental Control South Carolina Department of Health and Environmental Control STANDARD SPLIT-RAIL FENCE (TREE PROTECTION) South Carolina Department of Health and Environmental Control DATE SLOPE INDIVIDUAL RESIDENTIAL LOT CONTROLS LOT EXAMPLE "A" SLOPES TO FRONT LOT EXAMPLE "B" SLOPES TO REAR LOT EXAMPLE "C" SLOPES TO SIDE INDIVIDUAL LOTS SLOPE SLOPE South Carolina Department of Health and Environmental Control PLAN SYMBOL DATE South Carolina Department of Health and Environmental Control DATE PLAN SET KEY: 1- TS101-TITLE SHEET- NOTES- DETAILS 2- CS102 MOBILIZATION PLAN 4-CS103- GRADING & DRAINAGE PLAN 5-LS105- LANDSCAPE PLAN GROUNDCOVER PLANTING DETAIL MULTI-TRUNK TREE PLANTING DETAIL SHRUB PLANTING DETAIL 3 TS101 N.T.S. 4 TS101 N.T.S. 5 TS101 TREE INSTALLATION DETAIL N.T.S. N.T.S. 6 TS101 SITE GRADING PLAN NOTES: 1.VERIFY ALL BUILDING SETBACKS, BUFFERS AND LOT LINES PRIOR TO CONSTRUCTION. NO OFFSITE CONSTRUCTION IS PROPOSED. 2.CONSTRUCT DRIVEWAY AND SIDEWALKS TO ALLOW FOR DRAINAGE FLOW CONSISTENT WITH EXISTING DRAINAGE CONDITIONS. 3.ALL SITE IMPROVEMENTS TO COMPLY WITH APPLICABLE CITY OF BEAUFORT AND COMMUNITY REQUIREMENTS. 4.CONTRACTOR TO VERIFY SITE UTILITY AND STORM-WATER REQUIREMENTS AND ENSURE PROPOSED DRAINAGE COMPLIES WITH ANY PERMIT CONDITIONS. ALL CONSTRUCTION BMP's AND ANY APPLICABLE SCDHEC-OCRM PERMITTING IS ASSUMED TO BE HANDLED BY THE OWNER/CONTRACTOR DIRECTLY. 5.TREE PROTECTION REQUIRED ON ALL TREES TO BE MAINTAINED. SEE DETAIL ON THIS PAGE. EXISTING TREES HAVE BEEN APPROVED FOR GENERAL MAINTENANCE PRUNING FOR THE HEALTH OF THE TREES. 7. PROPOSED HOUSE FFE TO BE 26'-00". EXISTING GARAGE FLOOR FFE 24'-00". 8. ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. 9. SILT FENCING SHALL BE INSTALLED IF CONSTRUCTION OF DRIVE EXCEEDS A 48 HOUR PERIOD. 10. CONTRACTOR TO MAINTAIN STREET DRAIN INLETS DURING ENTIRE CONSTRUCTION PHASE OF PROJECT UNTIL ALL GROUND COVER ESTABLISHED. 11. A RAIN GARDEN IS NOT REQUIRED FOR THIS PHASE OF CELADON PER COUNTY STORM WATER REQUIREMENTS FOR WATER QUALITY. 12. PLAN PREPARED USING THE FOLLOWING REFERENCES: (A) M Brock Designs LLC- Site Plan, Mobilization, Grading Plan, & Landscape Plan (B)Surveying Consultants- Surveying (C) Sam Liberti- Low Tide Designs- Architecture TABBY CONCRETE APRON DETAIL 1 TS101 SECTION A-A' ON COMPACTED BASE CRUSHED GRANITE DRIVE 2 TS101 WIRE AND WOOD FENCE LIVING FENCING - 31 LF / 1 Gates "LIVING FENCE"N.T.S. 7 TS101 SITE COVERAGE: Homesite SF Total:14,549 SF (0.33 Acs) Building Footprint(s):Existing- 720 SF Proposed-2,342 SF Total:3,062 SF Impervious: Existing- 501 SF (Drive) Proposed- 1,788 SF (Gravel Drive, Landing, Pool Total: 2,289 SF Total Site Coverage:5,351 SF (36.7%) Total Open Space: 9,198 SF (63.3%) Disturbed Area:7,971 SF (0.18 Acs) Site Coverage ATTACHMENT 8 Page 36 Section VII. Item #1. RAMP 23 OF 4 SHEET 2 Chk'd By: Project ID: Issue / Revision DescriptionNo. Drawn Date: Chk'd By: Project ID: Sheet No. M. Brock po box 358, port royal south carolina, 29935 ph. 843.540.6407 mbrock@mbrockdesigns.com J. M. BROCK RLA copyright © M. Brock, RLA all rights reserved CS-102 Mobilization Plan E E Drawn By: Drawn By:M. Brock 1 25004 Site Development Plans For Mikulak Residence 95 Green St. Bluffton, SC 10.08.25 2 SUBMITTAL 12/25 MBDMOBILIZATION PLAN 1" =10'-0" PROJECT NOTES: Owner: Glenda Mikulak Property Address: 95 Green St. Property Lot Number: 2A Tax ID Number: R610 039 00A 0347 0000 Property Area: 0.334 Acres CONTRACTOR NOTE: ·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. STANDARD SPLIT-RAIL FENCE (TREE PROTECTION) South Carolina Department of Health and Environmental Control DATE SLOPE INDIVIDUAL RESIDENTIAL LOT CONTROLS LOT EXAMPLE "A" SLOPES TO FRONT LOT EXAMPLE "B" SLOPES TO REAR LOT EXAMPLE "C" SLOPES TO SIDE INDIVIDUAL LOTS SLOPE SLOPE South Carolina Department of Health and Environmental Control PLAN SYMBOL DATE South Carolina Department of Health and Environmental Control DATE FLAT-BOTTOM TRENCH DETAILV-SHAPED TRENCH DETAIL SILT FENCE INSTALLATION South Carolina Department of Health and Environmental Control Proposed Tree Protection Proposed Tree Protection Proposed Tree Protection Proposed Silt Fence Proposed Construction Entrance SITE COVERAGE: Homesite SF Total:14,549 SF (0.33 Acs) Building Footprint(s):Existing- 720 SF Proposed-2,342 SF Total:3,062 SF Impervious: Existing- 501 SF (Drive) Proposed- 1,788 SF (Gravel Drive, Landing, Pool Total: 2,289 SF Total Site Coverage:5,351 SF (36.7%) Total Open Space: 9,198 SF (63.3%) Disturbed Area:7,971 SF (0.18 Acs) Site Coverage ATTACHMENT 8 Page 37 Section VII. Item #1. HOUSE 26'-00" AMSL RAMP 15' x 35' POOL RAMP 23 UP DW OVEN ROBINS ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LNDRY/ENTRY TILE FLR. 10' 1 1/8" CLG. HT. M. CLST WOOD FLR. 10'-1 1/8" CLG. HT. M. BATH TILE FLR. 10'-1 1/8" CLG. HT. MASTER BEDROOM WOOD FLR. 10'-1 1 /8" CLG. HT. PWDR WOOD FLR. 10'-1 1/8" CLG. HT. PANTRY WOOD FLR. 10'-1 1/8" CLG. HT. HALL WOOD FLR. 10'-1 1/8" CLG. HT. KITCHEN WOOD FLR. 10'-1 1/8" CLG. HT. D. ROOM WOOD FLR. 10'-1 1/8" CLG. HT. L. ROOM WOOD-FLR. 10'-1 1/8" CLG. HT. BATH #2 TILE FLR. 10' 1 1/8" CLG. HT. CLOSET WOOD FLR. 10' 1 1/8" CLG. HT. SAFE ROOM WOOD FLR. 10'-1 1/8" CLG. HT. FRONT PORCH T&G FLR. SIDE PORCH T&G P.T. FLR. OF 4 SHEET 3 Chk'd By: Project ID: Issue / Revision DescriptionNo. Drawn Date: Chk'd By: Project ID: Sheet No. M. Brock po box 358, port royal south carolina, 29935 ph. 843.540.6407 mbrock@mbrockdesigns.com J. M. BROCK RLA copyright © M. Brock, RLA all rights reserved CS-103 Grading & Drainage Plan E E Drawn By: Drawn By:M. Brock 1 25004 Site Development Plans For Mikulak Residence 95 Green St. Bluffton, SC 10.08.25 2 SUBMITTAL 12/25 MBDGRADING & DRAINAGE PLAN 1" =10'-0" PROJECT NOTES: Owner: Glenda Mikulak Property Address: 95 Green St. Property Lot Number: 2A Tax ID Number: R610 039 00A 0347 0000 Property Area: 0.334 Acres TYPICAL BIORETENTION (Rain Garden) CROSS SECTION SITE GRADING PLAN NOTES: 1.VERIFY ALL BUILDING SETBACKS, BUFFERS AND LOT LINES PRIOR TO CONSTRUCTION. NO OFFSITE CONSTRUCTION IS PROPOSED. 2.CONSTRUCT DRIVEWAY AND SIDEWALKS TO ALLOW FOR DRAINAGE FLOW CONSISTENT WITH EXISTING DRAINAGE CONDITIONS. 3.ALL SITE IMPROVEMENTS TO COMPLY WITH APPLICABLE CITY OF BEAUFORT AND COMMUNITY REQUIREMENTS. 4.CONTRACTOR TO VERIFY SITE UTILITY AND STORM-WATER REQUIREMENTS AND ENSURE PROPOSED DRAINAGE COMPLIES WITH ANY PERMIT CONDITIONS. ALL CONSTRUCTION BMP's AND ANY APPLICABLE SCDHEC-OCRM PERMITTING IS ASSUMED TO BE HANDLED BY THE OWNER/CONTRACTOR DIRECTLY. 5.TREE PROTECTION REQUIRED ON ALL TREES TO BE MAINTAINED. SEE DETAIL ON THIS PAGE. EXISTING TREES HAVE BEEN APPROVED FOR GENERAL MAINTENANCE PRUNING FOR THE HEALTH OF THE TREES. 7. PROPOSED HOUSE FFE TO BE 26'-00". EXISTING GARAGE FLOOR FFE 24'-00". 8. ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. 9. SILT FENCING SHALL BE INSTALLED IF CONSTRUCTION OF DRIVE EXCEEDS A 48 HOUR PERIOD. 10. CONTRACTOR TO MAINTAIN STREET DRAIN INLETS DURING ENTIRE CONSTRUCTION PHASE OF PROJECT UNTIL ALL GROUND COVER ESTABLISHED. 11. A RAIN GARDEN IS NOT REQUIRED FOR THIS PHASE OF CELADON PER COUNTY STORM WATER REQUIREMENTS FOR WATER QUALITY. 12. PLAN PREPARED USING THE FOLLOWING REFERENCES: (A) M Brock Designs LLC- Site Plan, Mobilization, Grading Plan, & Landscape Plan (B)Surveying Consultants- Surveying (C) Sam Liberti- Low Tide Designs- Architecture Tree Canopy Coverage TREE CANOPY CALCULATION: Total Limit of Work Area:14,549 SF Building Footprint: 3,336 SF Remaining Site Area:11,213 SF Mature Canopy Coverage: 11,290 SF (Existing & Proposed) %Canopy Coverage (75% MIn.)77.59 % SITE COVERAGE: Homesite SF Total:14,549 SF (0.33 Acs) Building Footprint(s):Existing- 720 SF Proposed-2,342 SF Total:3,062 SF Impervious: Existing- 501 SF (Drive) Proposed- 1,788 SF (Gravel Drive, Landing, Pool Total: 2,289 SF Total Site Coverage:5,351 SF (36.7%) Total Open Space: 9,198 SF (63.3%) Disturbed Area:7,971 SF (0.18 Acs) CONTRACTOR NOTE: ·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. Proposed Pool By Others Proposed Crushed Granite Drive (1,242 SF) Proposed 4' Living Fence Existing Garage Carraiage House Proposed Rain Garden 68 SF Proposed Gravel Walks Proposed Tabby Paver Proposed Spot Elevation Proposed Drainage Arrow Site Coverage ATTACHMENT 8 Page 38 Section VII. Item #1. HOUSE 26'-00" AMSL RAMP 15' x 35' POOL RAMP 23 UP DW OVEN ROBINS ROOM WOOD FLR. 10'-1 1/8" CLG. HT. LNDRY/ENTRY TILE FLR. 10' 1 1/8" CLG. HT. M. CLST WOOD FLR. 10'-1 1/8" CLG. HT. M. BATH TILE FLR. 10'-1 1/8" CLG. HT. MASTER BEDROOM WOOD FLR. 10'-1 1 /8" CLG. HT. PWDR WOOD FLR. 10'-1 1/8" CLG. HT. PANTRY WOOD FLR. 10'-1 1/8" CLG. HT. HALL WOOD FLR. 10'-1 1/8" CLG. HT. KITCHEN WOOD FLR. 10'-1 1/8" CLG. HT. D. ROOM WOOD FLR. 10'-1 1/8" CLG. HT. L. ROOM WOOD-FLR. 10'-1 1/8" CLG. HT. BATH #2 TILE FLR. 10' 1 1/8" CLG. HT. CLOSET WOOD FLR. 10' 1 1/8" CLG. HT. SAFE ROOM WOOD FLR. 10'-1 1/8" CLG. HT. FRONT PORCH T&G FLR. SIDE PORCH T&G P.T. FLR. OF 4 SHEET 4 Chk'd By: Project ID: Issue / Revision DescriptionNo. Drawn Date: Chk'd By: Project ID: Sheet No. M. Brock po box 358, port royal south carolina, 29935 ph. 843.540.6407 mbrock@mbrockdesigns.com J. M. BROCK RLA copyright © M. Brock, RLA all rights reserved LS-104 Landscape Plan E E Drawn By: Drawn By:M. Brock 1 25004 Site Development Plans For Mikulak Residence 95 Green St. Bluffton, SC 11.18.25 2 SUBMITTAL 12/25 MBDLANDSCAPE PLAN 1" =10'-0" PROJECT NOTES: Owner: Glenda Mikulak Property Address: 95 Green St. Property Lot Number: 2A Tax ID Number: R610 039 00A 0347 0000 Property Area: 0.334 Acres CONTRACTOR NOTE: ·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. Plant Schedule Proposed Pool By Others Live Oak Proposed Crushed Granite Drive (1,242 SF) WIRE AND WOOD FENCE LIVING FENCING - 31 LF / 1 Gates "LIVING FENCE"N.T.S. 2 LS104 Tabby Pavers Proposed 4' Living Fence Proposed 6' Privacy Fence 6' PRIVACY FENCING N.T.S. 1 LS104 Approx. 92 LF/ 1- Double Gate Existing Garage Carraiage House CONTRACTOR NOTE: ·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT AFFECT NEIGHBORING PROPERTIES. #65 'Natchez' Crape Myrtle- Standard Dw Podocarpus Tea Olive Graceful Bamboo Live Oak Live Oak Live Oak Pink Muhly Grass Upright Holly Podocarpus Site Coverage ATTACHMENT 8 Page 39 Section VII. Item #1. ATTACHMENT 9 Page 40 Section VII. Item #1. ATTACHMENT 9 Page 41 Section VII. Item #1. ATTACHMENT 9 Page 42 Section VII. Item #1. ATTACHMENT 9 Page 43 Section VII. Item #1. ATTACHMENT 10 Page 44 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12-032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A1.1 COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 45 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12-032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03..20.13 A1.2 COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 46 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12-032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A2.1 COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 47 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12- 032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A3.1 COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 48 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12- 032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A3.2 COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 49 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12- 032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A4.1 COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 50 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12- 032 NOVEMBER 27 ,2012 01.28.13 03.11.13 03.20.13 A4.2 COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 51 Section VII. Item #1. A B D SHEET DATE: REVISION: DESIGNED BY DRAWN BY PROJECT NUMBER S. LIBERTI SAL 12-032 NOVEMBER 27 ,2012 01.28.13 03.11.13 E2.1 COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED. &23<5,*+7‹/2:7,'('(6,*167+(86(2)7+('2&80(17 6 $1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION ATTACHMENT 10 Page 52 Section VII. Item #1. M E M O R A N D U M TO: Historic Preservation Commissioners FROM: Town of Bluffton Growth Management Staff RE: Site Feature Permits from April 17, 2026, to May 16, 2026 DATE: June 1, 2026 SUMMARY: Town Staff will be updating the Historic Preservation Commission (HPC) monthly on all site feature permits that have been applied for, approved, denied, withdrawn, put on hold, or issued. These permits are reviewed at Staff level. Address Description of Application Staff Status 45 Bridge St Painting and front door repairs (HP Grant) Glen Umberger Approved 216 Bluffton Rd Signage: Hoof & Hound Caroline Luke Approved 8 Church St Porch Extension Caroline Luke Approved 5804 Ginkgo Ln Residential Reroof Caroline Luke Approved 194 Bluffton Rd Commercial window replacement Caroline Luke Approved 101 Calhoun St Renovations to church entrance Glen Umberger Applied 181 Bluffton Rd Unit C101 Signage: Bluffton Tax Advisor Caroline Luke Applied 2 Water St Carport Renovations Caroline Luke Applied 6 Church St Renovations to exterior (pathway, windows, etc.) Caroline Luke Applied Page 53 Section VIII. Item #1.

Source: Town of Bluffton website. First collected Nov 7, 2026.