Historic Preservation Commission Meeting — Agenda Packet
Town of Bluffton · Beaufort County · Historic Preservation Commission · meeting of Jun 3, 2026 · Agenda packets
Open the original document More from Town of Bluffton
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Historic Preservation Commission Meeting
Wednesday, June 03, 2026 at 6:00 PM
Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers,
20 Bridge Street, Bluffton, SC
AGENDA
This meeting can be viewed live on BCTV, on Sparklight Channel 9 and 417 or on Spectrum Channel
1304.
I. CALL TO ORDER
II. ROLL CALL
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by
a majority vote of the Commission Members present. Items which have not been heard before
9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined
by the Commission Members.
IV. ADOPTION OF MINUTES
1. May 6, 2026 Minutes
V. PUBLIC COMMENT
VI. OLD BUSINESS
VII. NEW BUSINESS
1. Certificate of Appropriateness (95 Green Street): A request by Glenda Mikulak Roberts,
Applicant and Owner, for review of a Certificate of Appropriateness-HD to construct a new
1.5-story house of approximately 2,342 SF at 95 Green Street in OId Town Bluffton Historic
District and zoned Neighborhood General-HD. (COFA-08-24-019275)(Staff-Charlotte Moore)
VIII. DISCUSSION
1. Historic District Monthly Update. (Staff)
2. Discussion regarding proposed amendments to non-contributing structures in Old Town
Bluffton Historic District. No attachments. (Staff)
IX. ADJOURNMENT
NEXT MEETING DATE: Wednesday, July 1, 2026
Page 1
Town of Bluffton, SC Historic Preservation Commission Meeting Agenda June 03, 2026
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance
with the Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the
Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of
disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA
compatible. Auditory accommodations are available. Any person requiring further accommodation
should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or
adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Executive Session – The public body may vote to go into executive session for any item identified for
action on the agenda.
*Please note that each member of the public may speak at one public comment session and a form must
be filled out and given to the Town Clerk. To submit a public comment online, please click here:
https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60
Public comment is limited to 3 minutes per speaker.
Page 2
Historic Preservation Commission Meeting
Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20
Bridge Street, Bluffton, SC
May 06, 2026
I. CALL TO ORDER
Chairman DePauw called the meeting to order at 6pm.
II. ROLL CALL
PRESENT
Chairman Joe DePauw
Vice Chair Carletha Frazier
Commissioner Jim Hess
Commissioner Tim Probst
Commissioner Lisa Sulka
Commissioner Michael Sutcliffe
ABSENT
Commissioner Debbie Wunder
III. ADOPTION OF MINUTES
1. March 4, 2026 Minutes
Commissioner Sulka made a motion to adopt the minutes as written.
Seconded by Vice Chair Frazier.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst,
Commissioner Sulka, Commissioner Sutcliffe
All were in favor and the motion passed.
IV. PUBLIC COMMENT
V. OLD BUSINESS
VI. NEW BUSINESS
1. Certificate of Appropriateness (204 Bluffton Road): A request by Thomas Michaels, Jr. (SM7
Design, LLC), Applicant, on behalf of 204 Bluffton Road, LLC, Owner, for approval of a
Certificate of Appropriateness to allow the construction of a 3-story 3,978 SF Main Street
Building at 204 Bluffton Road. The property is in the Promenade development in Old Town
Historic District and zoned Neighborhood Core-Historic District (NC-HD). (COFA-12-25-020072)
(Staff-Charlotte Moore)
Staff presented. The applicant was present. The commissioners had questions regarding
column spacing on the front porch, which the UDO requires to be wider than tall. The
commissioners discussed window placement on the side elevations, transom window
operability, door configurations on upper floors, and windowsill details. There was discussion
regarding the service yard door, brick material selection, and electric meter screening.
Page 3
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes May 06, 2026
Motion made by Commissioner Sulka made a motion to approve the application with the
following conditions:
1. Show all windows by type (i.e., label windows).
2. Show all doors by type (i.e., label doors).
3. Identify the roof configuration (mentioned to be standing seam metal at the HPC
meeting).
4. Revise plan to show porch ceilings with pressure-treated wood or cementitious board.
5. Provide railing details (for porches and the staircase).
6. Identify the brick to be used for the front porch columns and ground-floor wall
cladding (mentioned to be Savannah Grey at the HPC meeting).
7. If electric meters must be relocated, they must be screened with landscaping or
another screening method as determined by the HPRC.
8. Provide proof of a Right-of-Way encroachment permit for South Carolina Department
of Transportation for any work within Bluffton Road right-of-way.
9. The columns and posts must be redesigned and reviewed by the Historic Preservation
Review Committee (HPRC) for approval.
and the following were determined to be appropriate:
1.The use of powder-coated aluminum for the porch railings, balusters and handrails.
2. The use of Glastra material for windows and doors.
3. The placement of windows on the right and left elevations.
Seconded by Commissioner Hess.
Chairman DePauw made a motion to amend the motion to include the following
conditions:
1. For all porch doors with a panel door, install door hardware to give the
appearance of an operable door.
2. Provide sills for all window casings.
and include that the following is determined to be appropriate:
1. The use of fixed transom windows on the right and left elevations.
Seconded by Commissioner Sulka.
Voting Yea to amend the motion: Chairman DePauw, Vice Chair Frazier, Commissioner
Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe
All were in favor and the motion passed.
Voting Yea to the amended motion: Chairman DePauw, Vice Chair Frazier, Commissioner
Hess, Commissioner Probst, Commissioner Sulka, Commissioner Sutcliffe
All were in favor and the motion passed.
Page 4
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes May 06, 2026
VII. DISCUSSION
1. Historic District Monthly Update. (Staff)
Staff reviewed the monthly report. The Commissioners had no questions.
VIII. ADJOURNMENT
Commissioner Hess made a motion to adjourn.
Seconded by Commissioner Sulka.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Hess, Commissioner Probst,
Commissioner Sulka, Commissioner Sutcliffe
All were in favor and the motion passed. The meeting adjourned at 6:46pm.
Page 5
Section IV. Item #1.
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: June 3, 2026
PROJECT: COFA-08-24-019275
95 Green Street – New Construction of Single-family House
APPLICANT: Glenda Mikulak Roberts
PROPERTY OWNER: Glenda Mukulak Roberts
PROJECT MANAGER: Charlotte Moore, AICP, Principal Planner
APPLICATION REQUEST: The Applicant and Property Owner, Glenda Mikulak Roberts,
requests that the Historic Preservation Commission (HPC) approve the following
application:
A Certificate of Appropriateness to construct a 1.5-story single-family
residence of approximately 2,342 SF at 95 Green Street in Old Town Bluffton
Historic District, and within the Neighborhood General-HD (NG-HD) zoning
district.
INTRODUCTION: The house will be located at 95 Green Street, an unpaved road without
sidewalks, on a 0.33-acre double-frontage lot that includes an existing carriage house that
was constructed about 2014. The house will front Green Street and the rear yard will be
adjacent to Hickory Trace, also an unpaved road. A 36-inch live oak tree is located in the
middle of the lot and will be preserved.
The existing 1.5-story carriage house features a side-gable 5-V metal roof, inset balcony,
2/2 window configurations, square wood columns with bases and capitals, fiber
cementitious horizontal lap siding with board and batten siding underneath the gables, and
operable wood shutters (Attachment 10).
The proposed main structure has characteristics of a Vernacular House Building Type with
a roof ridge that is parallel to the front façade, includes side-facing gables, and a full-
façade front porch. However, the footprint is larger than is permitted by the Unified
Development Ordinance (1,800SF maximum vs. 1,912SF proposed) and the massing is
inconsistent with this building type, particularly the middle block that extends above the
Green Street-facing block. As the structure is not characteristic of other building types
permitted in the NG-HD District, it is reviewed as an Additional Building Type in
accordance with UDO Sec. 5.15.5.C.
The main structure has similar characteristics to the carriage house with some variations.
The structure will be located on a raised concrete slab with tabby stucco coating. The front
Page 6
Section VII. Item #1.
June 3, 2026 Page 2
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
porch and rear stoop will be located on CMU piers with unspecified brick veneer that will
be inset with pressure-treated wood horizontal boards. Wall cladding, including the
gables, will be Hardie board and batten (12” o.c.). A full-façade front porch on the Green
Street elevation features square wood columns with bases and capitals and a wood
balustrade, as does the inset porch on the left elevation. All windows are 2/2 fiberglass
double-hung except for shed dormer casement windows in the middle block and one in the
rear elevation. Exterior doors are a combination of metal clad, mahogany wood with a ¾
glass inset, and fiberglass (which is not a permitted material).
In addition to the main structure, a swimming pool, pool deck with pavers, and living and
privacy fences are proposed.
A Concept Plan was reviewed twice for this project. The Historic Preservation Review
Committee dates are September 3, 2024 and February 23, 2026. A response to the more
recent HPRC comments is provided in Attachment 9.
REVIEW CRITERIA & ANALYSIS: In its review of this COFA-HD application, Town Staff and
the Historic Preservation Commission are required to consider the criteria set forth in
Unified Development Ordinance (UDO) Section 3.18.3 (COFA-HD, Application Review
Criteria), applying the standards and guidelines of UDO Sec. 5.15, Old Town Bluffton
Historic District. The intent of the standards and guidelines is, in part, to provide guidance
and ensure consistent development without discouraging creativity or forcing the
replication of historic models.
The applicable criteria of UDO Sec.3.18.3 are provided below followed by a Staff Finding
based upon review of the application submittals to date.
1. Section 3.18.3.B. Consistency with the principles set forth in the Old Town
Master Plan.
a. Finding. The application is consistent with the principles set forth in the Old
Town Master Plan. The Old Town Master Plan states that “The built environment,
in particular the historic structures scattered throughout Old Town, should be
protected and enhanced. While it is of great importance to save and restore
historic structures, it is just as important to add to the built environment in a way
that makes Old Town more complete.”
Old Town Bluffton Historic District is a locally designated historic district. The
main structure has been designed to be sympathetic to the architectural
character of neighboring structures and will enhance the neighborhood by
adding architectural variety provided that the conditions noted in #2 of this
Section are met and determinations by HPC made. However, the massing of the
middle block is of concern as it is taller than the block facing Green Street.
Page 7
Section VII. Item #1.
June 3, 2026 Page 3
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
b. Finding. The Old Town Master Plan initiatives also include the adoption of a
form-based code that included architectural standards for structures located
within the Old Town Bluffton Historic District. These standards are included in
Article 5 of the UDO. The new construction will be in conformance with those
standards if the conditions noted in #2 of this Section are met and
determinations by HPC made.
c. Finding. The Old Town Master Plan initiatives also promote preservation and
protection of the legacy of the Old Town Bluffton Historic District through
additions to the built environment which make Old Town more complete. The
addition of new buildings contributes to the district as well as helps to provide
completeness to the neighborhood and overall district.
2. Section 3.18.3.C. The application must be in conformance with applicable
provisions provided in Article 5, Design Standards.
a. Findings. Town Staff finds that if the conditions noted below are met and/or
approved by the HPC, the proposed structure will be in conformance with
applicable provisions provided in Article 5:
(1) Service Yard (UDO Sec. 5.15.5.F.9.): Utility meters must be screened from
public view per the UDO; however, the electric utility requires that the
screening enclosure not include a gate. Therefore, the gate must be removed
or, alternatively, landscaping may be used to screen the meter.
(2) Chimney (UDO Sec. 5.15.6.E.8.c. and d.): The chimney is proposed to have
a bishop’s cap. While this is a traditional style for Old Town, a single bishop’s
cap applied to residential dwellings is increasingly disproportionately large.
Therefore, it is recommended that at least two bishop’s caps be applied to
the chimney. Additionally, the spark arrestor must be concealed with the
within the chimney.
(3) Building Walls (UDO Sec. 5.15.6.G.3.): Hardie board and batten is
proposed for building walls, including underneath the gable. The carriage
house has board and batten cladding but horizontal lap siding underneath
the gables. For consistency, it is recommended that this pattern also be
applied to the main structure. If a metal roof is proposed, this would also
break up the verticality of the structure (Note: shingle material is mentioned
in the application and the plan set, but a metal roof is shown).
(4) Brick (UDO Sec. 5.15.6.G.3.h.): UDO states that for the use of brick,
“[w]herever possible, green building materials…including recycled content
sheathing, siding composed of reclaimed or recycled material, salvaged
masonry brick or block, and locally produced stone or brick” should be used.
Page 8
Section VII. Item #1.
June 3, 2026 Page 4
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
Information regarding the proposed brick has not been provided for the piers.
In the recent past, Savannah Grey or similar tumbled brownish-grey brick
has been approved by the HPC. It is recommended that a sample brick or cut
sheet be provided for Historic Preservation Review Committee approval.
(5) Doors (UDO Sec. 5.15.5.6.I.2.b.): The door on the rear elevation is proposed
to be fiberglass. The UDO permits only wood, metal or metal-clad.
(6) Windows (UDO Sec. 5.15.6.I.3.b.): For the main house, fixed windows are
proposed on the Right and Rear elevations, which is not a permitted
configuration. These windows must be changed to a casement operation
unless otherwise approved by HPC.
(7) Roof (UDO Sec. 5.15.6.J.): The UDO permits both metal (galvanized, copper,
aluminum, zinc-alum) and shingles (metal, dimensional asphalt, slate and
composite slate) roofs. The project analysis sheet and the flashing details
sheet suggest that asphalt shingles will be used; however, the drawings
show a metal roof. The correct roof must be shown and include the specific
material and configuration per UDO Sec. 5.15.6.J.).
(8) Trim: Certain trim pieces on the Front Door Elevation and Sill details (Sheet
A6.1) show “hardie plan or azek.” Azek is not a UDO permitted material. The
inclusion of this material may be an error based on the Applicant’s response
to HPRC comments (Attachment 9).
(9) Shutters (UDO Sec. 5.15.6.M.): Shutters are not a requirement, but they are
provided on the carriage house. While the structure includes adequate
fenestration, there are portions of wall area that lack visual interest and/or
spacing between windows is wide (such as the front porch). Therefore, it is
recommended that shutters be provided that are consistent with UDO Sec.
5.15.6.M.
3. Section 3.18.3.D. Consistency with the nature and character of the surrounding
area and consistency of the structure with the scale, form and building
proportions of the surrounding neighborhood.
Finding . The mass and scale of the main structure is appropriate for its location and
the architectural detailing, with revisions to address the items in #2 above, will be
sensitive to the neighboring properties. However, the mass and scale of the
Carriage House appears disproportionately larger than the main house.
4. Section 3.18.3.H. The application must comply with applicable requirements in
the Applications Manual.
Page 9
Section VII. Item #1.
June 3, 2026 Page 5
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
Finding. The Certificate of Appropriateness Application has been reviewed by Town
Staff and has been determined to be complete except for the applicable items in #2.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using the
review criteria established in the UDO and to take appropriate action as granted by the
powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that with the conditions
noted below, the requirements of Section 3.18.3 of the Unified Development Ordinance
have been met and recommends that the Historic Preservation Commission approve the
application subject to the following conditions and determinations:
Conditions:
1. Remove the gate for the utility meter screening fence or, alternatively, provide
landscaping to screen the meter.
2. Provide two bishop’s caps for the chimney cap and conceal the spark arrestor
within the chimney.
3. Provide horizontal lap siding underneath the gables to match the cladding of the
carriage house.
4. Provide the source and type of brick proposed to be used for review and approval by
the HPRC.
5. Provide a rear elevation door that is wood, metal or metal-clad.
6. Change fixed windows to casement windows (or other window configuration that
may be approved by HPC).
7. Consistent with UDO Sec. 5.15.6.J., provide the exact roof material and
configuration.
8. Remove references to Azek material (unless otherwise approved by the HPC as an
alternate material).
9. Provide shutters that are consistent with UDO Sec. 5.15.6.M.
Determination:
A determination from the HPC is needed regarding the appropriateness of the following:
1. The massing of the middle block of the structure, as it is taller than the Green Street
front elevation block.
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties
set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to
take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
Page 10
Section VII. Item #1.
June 3, 2026 Page 6
95 Green Street – Certificate of Appropriateness Historic Preservation Commission
2. Approve the application with conditions; or
3. Deny the application as submitted by the Applicant.
ATTACHMENTS:
1. Application
2. Location & Zoning Map
3. Photos
4. Survey
5. Site Plan
6. Narrative
7. Architectural Plans
8. Landscape Plan
9. Response to HPRC Comments
10. Carriage House Plans (2013)
Page 11
Section VII. Item #1.
ATTACHMENT 1
Page 12
Section VII. Item #1.
ATTACHMENT 1
Page 13
Section VII. Item #1.
ATTACHMENT 1
Page 14
Section VII. Item #1.
ATTACHMENT 1
Page 15
Section VII. Item #1.
LOCATION & ZONING MAP
95 Green Street
Neighborhood General-HD District
ATTACHMENT 2
Page 16
Section VII. Item #1.
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
Designer
Author
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A0.6
ATTACHMENT 3
Page 17
Section VII. Item #1.
ATTACHMENT 4
Page 18
Section VII. Item #1.
HOUSE
26'-00" AMSL
24.00'FG
23.00'FG
24.25'TC
24.00'FG24.00'FG
23.50'FG
24.00'TC
24.25'TC
24.00'FG24.00'FG
24.00'FG
23
24.25'TC
24.00'TC
UP
DW
OVEN
PHONE
CABLE
65' - 5 1/2"
36' - 0"
16' - 4 1/4"15' - 0" 34' - 1 1/4"
2' - 11"
3' - 9 1/2" 3' - 0"
7' - 0"
16' - 0"8' - 6 13/16"17' - 10 1/2"8' - 1 3/16"
9' - 4 1/4"5' - 10"9' - 4 1/2"11' - 5 1/4"
6' - 5"14' - 10"14' - 9"
18' - 0 1/2"
5' - 3"5' - 4"
7' - 2"2' - 8"
5' - 7 1/4"
JOYOUS TWO
PERSON SAUNA
1' - 2"3' - 1"1' - 2"
30" x 60"
1' - 10 1/2"
1' - 2"4' - 8"1' - 2"
7' - 1"
9"
14' - 11"
65' - 5 1/2"
7' - 1"
ROBINS ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LNDRY/ENTRY
TILE FLR.
10' 1 1/8" CLG. HT.
M. CLST
WOOD FLR.
10'-1 1/8" CLG. HT.
M. BATH
TILE FLR.
10'-1 1/8" CLG. HT.
MASTER
BEDROOM
WOOD FLR.
10'-1 1 /8" CLG. HT.
PWDR
WOOD FLR.
10'-1 1/8" CLG. HT.
PANTRY
WOOD FLR.
10'-1 1/8" CLG. HT.
HALL
WOOD FLR.
10'-1 1/8" CLG. HT.
KITCHEN
WOOD FLR.
10'-1 1/8" CLG. HT.
D. ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
L. ROOM
WOOD-FLR.
10'-1 1/8" CLG. HT.
VANITY AREA
10' - 0"2' - 10"8' - 8"
36' - 0"
4' - 2"
2' - 2 1/2"
DESK
5' - 8 3/4"6' - 5"5' - 8 3/4"
5' - 8 1/2" 6' - 3" 2' - 10 1/4"
BATH #2
TILE FLR.
10' 1 1/8" CLG. HT.
CLOSET
WOOD FLR.
10' 1 1/8" CLG. HT.
SAFE ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LOW AREA
UNDER LANDING
LIN.
4' - 1 1/4"
3' - 4 3/4"
FRONT PORCH
T&G FLR.
SIDE PORCH
T&G P.T. FLR.
17' - 10 1/2"
3' - 10 1/4"10' - 8 1/4"
5' - 1 3/4"
5' - 1"
4' - 6 1/4"2' - 6"7' - 10 3/4"
3' - 11 1/2" 9' - 0 1/2"
5' - 11 1/2"
11' - 0 1/2"
6' - 1"
4' - 0 7/8"
4"
4"
4' - 0"
3' - 0 21/32"
meter
head
trash recept. at garage
7' - 5 1/2"7' - 5 1/2"
3' - 6"
3' - 6 1/16"
8' - 11 1/4"8' - 11 1/4"
7' - 8"
3' - 8"
8 5/8"
W/D
STACK
2' - 8 1/2"10' - 10"9' - 1 1/2"9' - 4 7/16"2' - 11"10' - 3 9/16"7' - 8"9' - 8"2' - 10 1/2"
5' - 10 1/4" 12' - 1 3/4" 12' - 2" 5' - 10"
1' - 0 1/2"
9"3" 3"
3' - 10 1/2" 7' - 4 3/4" 6' - 4" 10' - 8"
8' - 0"8' - 0"8' - 6 13/16"4' - 5 17/32"4' - 5 3/4"4' - 5 3/4"4' - 5 15/32"4' - 2 3/4"3' - 10 7/16"7' - 5 1/2"7' - 5 1/2"
2' - 10"9' - 10"
4
5
19
18
15
16
17
14
13 2 1 3
12 11
10
8
9
76
open
door
3/0 X 6/0
WOOD GATE
3/0 X 6/0
WOOD GATE
10A
1ST FL 26.00'
NAVD88
FP 25.917'
NAVD88
RP 25.83'
NAVD88
SY 23.4'
NAVD88
FP 25.917'
NAVD88
TEMPERED
GLASS
5 1/2"
BRICK
HEARTH
3' - 4 1/2"2' - 0"
2' - 8 1/2"1' - 2"4' - 8"1' - 2"4' - 9"
EXISTING CARRIAGE
HOUSE
RAMP
DOWN
7' - 8 3/4"
6 1/4"6 1/4"
4' - 8"
HOUSE
26'-00" AMSL
24.00'FG
23.00'FG
24.25'TC
24.00'FG24.00'FG
23.50'FG
24.00'TC
24.25'TC
RAMP
15' x 35' POOL
RAMP
24.00'FG24.00'FG
24.00'FG
23
24.25'TC
24.00'TC
ATTACHMENT 5
Page 19
Section VII. Item #1.
ATTACHMENT 6
Page 20
Section VII. Item #1.
GENERAL NOTES
· NOTES TO GENERAL CONTRACTORS:
THESE DRAWINGS HAVE BEEN PRODUCED UNDER A LIMITED S ERVICE AGREEMENT BETWEEN THE
OWNER AND LOW TIDE DESIGNS. THEY ARE TO BE USED IN CONJUNCTION WITH STRUCTURAL AND
OTHER ENGINEERING REQUIREMENTS FOR A BUILDING PERMI T.
· THESE DRAWINGS CANNOT STAND ALONE AS CONSTRUCTION D OCUMENTS
· SEE STRUCTURAL ENGINEERING DOCUMENTS FOR STRUCTURAL CONNECTION TECHNIQUES,
CALCULATIONS THAT ARE REQUIRE BY CODE. CODE COMPLIA NCE INSTRUCTIONS FOR WALL AND ROOF
CONSTRUCTION AND TIE DOWN REQUIREMENTS
· SEPARATE MECHANICAL AND PLUMBING ENGINEERING DOCUME NTS MAY BE PROVIDED WHICH WOULD
INDICATE REQUIRED SERVICE AND RISER DIAGRAMS, CALCU LATIONS AND INSTALLATION
SPECIFICATIONS BEYOND THE RESIDENTIAL DESIGNERS BAS IC LAYOUT AND SELECTIONS
· SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDE D WHICH INDICATE ADDITIONAL SITE PREP
PLANNING, AND DRAINAGE.
· SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNER/OWNERS
REPRESENTATIVE OR BUILDER..
· BY APPLYING FOR A BUILDING PERMIT AND /OF CONSTRUCT ING THE PROJECT REPRESENTED HER IN,
THE OWNER AGREES TO LIMIT THE LIABILITY OF THE RESI DENTIAL DESIGNER TO THE OWNER OF THE
PROJECT FOR ALL AND ANY CLAIMS, LOSSES, DAMAGES OR ANY NATURE WHATSOEVER OR CLAIMS OF
EXPENSE FOR ANY SUCH ITEMS TO THE RESIDENTIAL DESIG NERS TOTAL COMPENSATION FOR
SERVICES RENDERED HEREIN.
· THESE DOCUMENTS ARE THE WORK INSTRUMENTS OF THE RES IDENTIAL DESIGNER AND HAVE BEEN
PREPARED SPECIFICALLY AND ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER
LOCATIONS WITHOUT THE PARTICIPATION OF THE RESIDENT IAL DESIGNER. REPRODUCTION IS
STRICTLY PROHIBITED. THE RESIDENTIAL DESIGNER SHALL BE DEEMED THE AUTHOR AND OWNER OF
THESE DOCUMENTS AND SHALL RETAIN COMMON LOW STATUTO RY AND OTHER RESERVED RIGHTS,
INCLUDING THE COPY RIGHT.
· THIS WRITTEN NOTICE BY THE SOUTH CAROLINA REGULATIO NS TO THE PERMITTING AUTHORITY AND
BUILDING OWNER THAT THE RESIDENTIAL DESIGNER AT LOW TIDE DESIGNS HAVE NOT BEEN HIRED TO
PROVIDE MINIMUM CONSTRUCTION ADMINISTRATION SERVICE S ON THE FOLLOWING PROJECT.
· FOR DIMENSIONS NOT SHOWN OR IN QUESTION, THE CONTRA CTOR WILL REQUEST CLARIFICATION
FROM THE RESIDENTIAL DESIGNER BEFORE PROCEEDING.
· CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD. ANY DISCREPANCIES WILL BE
BROUGHT TO THE RESIDENTIAL DESIGN BEFORE PROCEEDING .
· INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE
GENERAL CONTRACTOR IN EXECUTING THE WORK . EVERY AT TEMPTS HAS BEEN MADE TO PROVIDE
COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH CONDI TIONS.
· WHEN ARCHITECTURAL DRAWINGS ARE IN CONFLICT WITH TH E ENGINEERING DRAWINGS THE GENERAL
CONTRACTOR SHALL REQUEST CLARIFICATIONS FROM THE RE SIDENTIAL DESIGNER BEFORE
PROCEEDING.
LOW TIDE DESIGNS HAS NOT BEEN HIRED FOR CONSTRUCTION
MANAGEMENT OR OBSERVATION ON THIS PROJECT.
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
CS
SHEET LIST
SHEET NUMBER SHEET NAME
CS COVER SHEET
A0.0 ORIGINAL SITE PLAN
A0.1 SITE PLAN
A0.2 DRAINAGE
A0.3 STREETSCAPE
A0.5 STORM WATER INFORMATION
LS LANDSCAPING
A1.1 FOUNDATION PLAN
A2.1 FIRST FLOOR PLAN
A2.2 SECOND FLOOR PLAN
A2.3 ROOF PLAN
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A3.3 3D EXTERIOR VIEWS
A4.1 BUILDING SECTIONS
A4.2 WALL SECTIONS
A4.3 WALL SECTIONS
A4.4 DETAILS
A4.5 FLASHING DETAILS
A5.0 WINDOW & DOOR SCHEDULE
A5.1 WINDOW DETAILS
A5.2 WINDOW DETAILS
A6.1 DOOR DETAILS
E2.1 FIRST FLOOR ELECTRICAL PLAN
E2.2 SECOND FLOOR ELECTRICAL PLAN
S0.1 STRUCTURAL
BUILDING CODE SUMMARY
NAME OF PROJECT:
ADDRESS:
PROPOSED USE:
OWNER/CONTACT:
CODE ENFORCEMENT JURISDICATION:
DESIGNER OF RECORD
DESIGNER
ELECTRICAL
PLUMBING
MECHANICAL
STRUCTURAL
CIVIL
LANDSCAPER
BUILDING DATA
OCCUPANCY CLASSIFICATION
MIXED OCCUPANCY
CONSTRUCTION TYPE
MIXED CONSTRUCTION
SPRINKLERED
FIRE DISTRICT
BUILDING HEIGHT 24'-2 13/16"
GLENDA AND BILLY MIKULAK
LOT #2 AND 2A GREEN STREET
BLUFFTON, SOUTH CAROLINA
RESIDENTIAL
GLENDA MIKULAK
TOWN OF BLUFFTON, SC
LOW TIDE DESIGNS
__________
BLUFFTON, SC 29910 843-815-9575
__________
__________
__________
__________
MICHAEL BROCK RLA
__________
__________
__________
__________
__________
PORT ROYAL SC
__________
__________
__________
__________
__________
843.540.6407
RESIDENTIAL R-3
NO SEPARATION
I-A I-B II-B
III-A III-B IV V-A V-B
NO TYPE
NO
NO
BUILDING STORIES 1.5
1 3D FRONT VIEW 1-COVER
ATTACHMENT 7
Page 21
Section VII. Item #1.
DN
4' - 10" 65' - 5 1/2" 7' - 0"
16' - 8" 34' - 0 1/4" 14' - 9 1/4"
37' - 5 9/16" 6' - 0" 21' - 11 15/16"
16' - 11 1/2" 3' - 6" 30' - 2 3/4" 14' - 9 1/4"
36' - 0"
6' - 0"
6' - 2 1/4" 15' - 2 1/2" 14' - 7 1/4"
4' - 10" 16' - 0" 8' - 6 13/16" 17' - 10 1/2" 8' - 1 3/16" 14' - 11" 6' - 11"
5' - 8 3/4" 6' - 5" 5' - 8 3/4"
7' - 11 1/2"
5' - 11 1/2" 11' - 0 1/2" 19' - 0"
6' - 2 1/4" 15' - 2 1/2" 14' - 7 1/4"
4' - 3 1/2" 6' - 9" 8' - 10" 4' - 10" 5' - 4"
10' - 8 1/4" 5' - 11 3/4" 3' - 9 1/2" 4' - 1 5/16"
9' - 7" 14' - 10" 11' - 7"
8' - 2 7/8" 14' - 9 1/4"
6" 4' - 4"
22' - 0 1/8" 6 1/8" 4' - 5" 6 1/8" 8' - 6 5/8"
8 1/4"9' - 10"2' - 10"8' - 8"2' - 10"9' - 10"10 1/4"
3 3/4"1 3/4"
36' - 0"
6' - 5" 6"5' - 8 3/4" 6' - 5" 5' - 8 3/4"
6" 4' - 4"
6' - 5" 6"
F1
F1
F1
F2
F3 F14
F14
F14
F14
F14
THESE PIERS BRICK
TWO SIDES
THESE PIERS BRICK
TWO SIDES THESE PIERS BRICK
TWO SIDES
F14
8" THICKENED SLAB
UNDER FIREPLACE
PROVIDE GAS
STUB
PROVIDE GAS
STUB COOK
TOP
2 X 8 16" PT FLOOR JOIST 2 X 8 16" PT FLOOR JOIST
2 X 8 16" PT FLOOR JOIST
1ST FL 26.00'
NAVD88
FP 25.917'
NAVD88
RP 25.83'
NAVD88
SY 23.4'
NAVD88
FP 25.917'
NAVD88
RECESS
FLOOR 4"
DWN
DWN
POOL TERRACE
POOL BY
CONTRACTOR
5' DEEP W/ RAMP
1' - 4"
1' - 4"
2' - 0"
2' - 0"
6"
6"
DWN 1"
DWN 1"
DWN 1"
1' - 4"
1' - 4"
1' - 4"
1' - 4"
1' - 4"
1' - 4"
1' - 4"1' - 4"
1' - 4"
1' - 4"
1' - 4"
1' - 4"
1' - 4"
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A1.1
1/4" = 1'-0"1 FOUNDATION PLAN
MASTER NOTE SCHEDULE
NOTE
NUMBER NOTE
F1 4" THICK 3,000 PSI CONCRETE SLAB
REINF. W/ 6X6 #10/#10 W.W.M. ON 6 MIL
POLYETHYLENE VAPOR BARRIER ON
CLEAN, DRY, COMPACTED, TERMITE
TREATED EARTH FILL.
F2 8" WIDE X 12" DEEP, 3,000 PSI
MONOLITHIC CONCRETE FOOTING W/ #4
BAR CONT. OVERLAP ENDS 40X DIA. MIN.,
EXTEND 6X6 #10/#10 W.W.M. FROM CONC.
SLAB INTO FOOTING.
F3 4" THICK, 3,000 PSI CONCRETE SLAB
REINF. W/ 6X6 #10/#10 W.W.M. ON CLEAN,
DRY, TREATED, COMPACTED EARTH FILL.
F4 16" X 16" CMU PIER ON 3' X 3' X 18"
CONCRETE FOOTING WITH (3) 5/8" REBAR
EACH WAY. (2) 5/8" VERTICAL RODS. FILL
PIER W/ 3000 PSI GROUT.
F5 16" X 16" CMU PIER ON 3' X 3' X 18"
CONCRETE FOOTING WITH (3) 5/8" REBAR
EACH WAY. (2) 5/8" VERTICAL RODS. FILL
PIER W/ 3000 PSI GROUT.
F6 8" X 16" CMU WALL W/5/8" VERTICAL
REBAR IN EACH CORNER @32"O.C.. FILL
CMU WALL WITH CONCRETE GOUT 2500
PS FILL WITH TREATED COMPACTED
SOIL. 32" WIDE X 16" DEEP CONCRETE
FOOTING WITH (3) 5/8" REBAR OVERLAP
40 X DIA.
F7 DEPRESS SLAB AT SLIDING DOOR 1-3/4"
TO ACCEPT DOOR SILL. SEE FLOOR
PLAN FOR LOCATION OF SLIDING DOORS.
F8 PROVIDE SOLID MASONRY STUCCO TRIM,
SURROUND & PILASTERS NO QUIK-R,
B-BOARD SHALL BE USED ON
RESIDENCE.
F9 ANY WOOD, PLYWOOD OR FIBROUS
MATERIAL INSTALLED AGAINST A
MASONRY SURFACE SHALL BE OF A
PRESSURE TREATED NATURE. ANY
MATERIAL INSTALLED BELOW FLOOD
SHALL BE NON-SOLUBLE. NO
EXCEPTIONS.
F10 16" WIDE X 36" +/- DEEP 3,000 PSI
MONOLITHIC CONC. FOOTING W/ #4 BAR
CONT. OVERLAP ENDS 40X DIA. MIN.,
EXTEND 6X6 #10/#10 W.W.M. FROM
CONCRETE SLAB INTO FOOTING
F11 NOT USED.
F12 16" WIDE X 20" +/- DEEP, 3,000 PSI
MONOLITHIC CONCRETE FOOTING W/ #4
BAR CONT. OVERLAP ENDS 40X DIA. MIN.,
EXTEND 6X6 #10/#10 W.W.M. FROM
CONCRETE SLAB INTO FOOTING.
F13 24" WIDE X 20" DEEP, 3,000 PSI
MONOLITHIC CONCRETE FOOTING W/ #4
BAR CONT. OVERLAP ENDS 40X DIA. MIN.,
EXTEND 6X6 #10/#10 W.W.M. FROM
CONCRETE SLAB INTO FOOTING.
F14 20" WIDE X 20" DEEP, 3,000 PSI
MONOLITHIC CONCRETE FOOTING W/ #5
BAR CONT. OVERLAP ENDS 40X DIA. MIN.,
EXTEND 6X6 #10/#10 W.W.M. FROM
CONCRETE SLAB INTO FOOTING. BRICK
VENEER OVER 8 X 8 X 8 CMU PIER FILLED
SOLID
F15 24" WIDE X 12" DEEP, 3,000 PSI
MONOLITHIC CONCRETE GRADE BEAM
W/ #5 BAR CONT. OVER LAP ENDS 40X
D1
1
F10
F10
F10
F10
F10
F10
F10
F10
F15
F15
F15
ATTACHMENT 7
Page 22
Section VII. Item #1.
L AV 15' x 35' POOL
RAMP
FILTER
24"
AQUACAL
SQ166R
HEAT/COOL PUM
P
23.8
UP
DW
OVEN
PHONE
CABLE
65' - 5 1/2"
36' - 0"
16' - 4 1/4" 15' - 0"34' - 1 1/4"
2' - 11"
3' - 9 1/2"3' - 0"
7' - 0"
16' - 0" 8' - 6 13/16" 17' - 10 1/2" 8' - 1 3/16"
9' - 4 1/4" 5' - 10" 9' - 4 1/2" 11' - 5 1/4"
6' - 5" 14' - 10" 14' - 9"
18' - 0 1/2"
5' - 3" 5' - 4"
7' - 2" 2' - 8"
5' - 7 1/4"
JOYOUS TWO
PERSON SAUNA
1' - 2" 3' - 1" 1' - 2"
30" x 60"
1' - 10 1/2"
1' - 2" 4' - 8" 1' - 2"
7' - 1"
9"
14' - 11"
65' - 5 1/2"
7' - 1"
ROBINS ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LNDRY/ENTRY
TILE FLR.
10' 1 1/8" CLG. HT.
M. CLST
WOOD FLR.
10'-1 1/8" CLG. HT.
M. BATH
TILE FLR.
10'-1 1/8" CLG. HT.
MASTER
BEDROOM
WOOD FLR.
10'-1 1 /8" CLG. HT.
PWDR
WOOD FLR.
10'-1 1/8" CLG. HT.
PANTRY
WOOD FLR.
10'-1 1/8" CLG. HT.
HALL
WOOD FLR.
10'-1 1/8" CLG. HT.
KITCHEN
WOOD FLR.
10'-1 1/8" CLG. HT.
D. ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
L. ROOM
WOOD-FLR.
10'-1 1/8" CLG. HT.
VANITY AREA
10' - 0" 2' - 10" 8' - 8"
36' - 0"
4' - 2"
2' - 2 1/2"
DESK
5' - 8 3/4" 6' - 5" 5' - 8 3/4"
5' - 8 1/2"6' - 3"2' - 10 1/4"
BATH #2
TILE FLR.
10' 1 1/8" CLG. HT.
CLOSET
WOOD FLR.
10' 1 1/8" CLG. HT.
SAFE ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LOW AREA
UNDER LANDING
LIN.
4' - 1 1/4"
3' - 4 3/4"
FRONT PORCH
T&G FLR.
SIDE PORCH
T&G P.T. FLR.
17' - 10 1/2"
3' - 10 1/4" 10' - 8 1/4"
5' - 1 3/4"
5' - 1"
4' - 6 1/4" 2' - 6" 7' - 10 3/4"
3' - 11 1/2"9' - 0 1/2"
5' - 11 1/2"
11' - 0 1/2"
6' - 1"
4' - 0 7/8"
4"
4"
4' - 0"
3' - 0 21/32"
meter
head
trash recept. at garage
7' - 5 1/2" 7' - 5 1/2"
3
A4.1
2
A4.1
2
A4.3
3' - 6"
3' - 6 1/16"
8' - 11 1/4" 8' - 11 1/4"
1
A4.1
7' - 8"
3' - 8"
8 5/8"
W/D
STACK
2' - 8 1/2" 10' - 10" 9' - 1 1/2" 9' - 4 7/16" 2' - 11" 10' - 3 9/16" 7' - 8" 9' - 8" 2' - 10 1/2"
5' - 10 1/4"12' - 1 3/4"12' - 2"5' - 10"
1' - 0 1/2"
9" 3"3"
3' - 10 1/2"7' - 4 3/4"6' - 4"10' - 8"
8' - 0" 8' - 0" 8' - 6 13/16" 4' - 5 17/32" 4' - 5 3/4" 4' - 5 3/4" 4' - 5 15/32" 4' - 2 3/4" 3' - 10 7/16" 7' - 5 1/2" 7' - 5 1/2"
2' - 10" 9' - 10"
F
F
F
C C
CC
BCCC
CC
CC
4
5
19
18
15
16
17
14
13213
1211
10
8
9
7 6
open
door
3/0 X 6/0
WOOD GATE
3/0 X 6/0
WOOD GATE
10A
1ST FL 26.00'
NAVD88
FP 25.917'
NAVD88
RP 25.917'
NAVD88
SY 23.4'
NAVD88
FP 25.917'
NAVD88
1
A4.2
2
A4.2
TEMPERED
GLASS
5 1/2"
3
A4.4
A4.4
4
4
A4.1
BRICK
HEARTH
3' - 4 1/2" 2' - 0"
2' - 8 1/2" 1' - 2" 4' - 8" 1' - 2" 4' - 9"
EXISTING CARRIAGE
HOUSE
5
A4.4
RAMP
DOWN
G
7' - 8 3/4"
6 1/4" 6 1/4"
4' - 8"
5
A4.1
GENERAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE
CURRENT EDITION OF THE 20121 I.R.C. (INTERNATIONAL
RESIDENTIAL CODE), WITH SOUTH CAROLINA
AMENDMENTS, IECC 2009 ENERGY CODE AND ICC 600
HIGH WIND CONSTRUCTION
2. PROVIDE HURRICE CLIPS AT ALL RAFTERS AND JOISTS.
AT ALL EXTERIOR DECK FLOOR JOISTS PROVIDE
GALVANIZED HURRICANE CLIPS.
3. ALL PLUMBING WORK SHALL CONFORM TO LOCAL,
STATE, AND FEDERAL CODES INCLUDING THE
CURRENT EDITION OF THE STANDARD PLUMBING CODE.
USE WATER EFFICIENT FIXTURES AND LOCATE HOT
WATER HEATERS CLOSE TO LARGE USAGE FIXTURES TO
MINIMIZE LOADING.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATION WITH LOCAL OR PRIVATE UTILITY
COMPANIES OR AGENCIES FOR RELOCATION OF,
OR CONNECTION TO EXISTING UTILITIES.
5. THE TOP HEAD OF EXTERIOR DOORS AND WINDOWS TO BE
AT THE SAME HEIGHT ABOVE THE FINISH FLOOR U.N.O.
6. ALL EXTERIOR WALLS ARE 2x6, U.N.O.
7. ALL INTERIOR WALLS ARE 2x4, EXCEPT WHERE NOTED.
8. ANY MATERIAL IN CONTACT WITH CONCRETE SHALL
BE PRESSURE TREATED.
9. ALL MATERIAL BELOW FLOOD SHALL BE NON-SOLUBLE
MATERIAL.
10. CONTRACTOR AND SUBS SHALL REVIEW PLANS PRIOR
TO CONSTRUCTION. CONTACT DESIGNER IF QUESTIONS
ARISE BEFORE BUILDING.
11. PROVIDE INSULATION BEHIND ALL TUBS. INSTALL WITH
NO VOIDS.
12. 5/8" TYP "WR & X" AT CLG OF GARAGE
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A2.1
1/4" = 1'-0"1 FIRST LEVEL F.F.
ATTACHMENT 7
Page 23
Section VII. Item #1.
UP
-
---
-
---
-
---
-
---
2 3/4"
2 3/4"
2 3/4"2 3/4"
PROVIDE EGRESS
WINDOWS
PROVIDE EGRESS
WINDOWS
1' - 11"1' - 11"
3 5/8" 1 7/8"
-
---
3
A4.1
2
A4.12
A4.3
1
A4.1
4' - 9"
DDD
EEE
E E E
4' - 9 9/16" 3' - 10 1/4"
12' - 9 7/16" 2' - 3 3/4" 2' - 11" 2' - 11" 2' - 3 3/4" 13' - 10 9/16" 12' - 10"
21
20 22
A 1
A4.2
2
A4.2
TEMPERED
GLASS
4
A4.1
-
---
5
A4.1
GENERAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE
CURRENT EDITION OF THE 20121 I.R.C. (INTERNATIONAL
RESIDENTIAL CODE), WITH SOUTH CAROLINA
AMENDMENTS, IECC 2009 ENERGY CODE AND ICC 600
HIGH WIND CONSTRUCTION
2. PROVIDE HURRICE CLIPS AT ALL RAFTERS AND JOISTS.
AT ALL EXTERIOR DECK FLOOR JOISTS PROVIDE
GALVANIZED HURRICANE CLIPS.
3. ALL PLUMBING WORK SHALL CONFORM TO LOCAL,
STATE, AND FEDERAL CODES INCLUDING THE
CURRENT EDITION OF THE STANDARD PLUMBING CODE.
USE WATER EFFICIENT FIXTURES AND LOCATE HOT
WATER HEATERS CLOSE TO LARGE USAGE FIXTURES TO
MINIMIZE LOADING.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATION WITH LOCAL OR PRIVATE UTILITY
COMPANIES OR AGENCIES FOR RELOCATION OF,
OR CONNECTION TO EXISTING UTILITIES.
5. THE TOP HEAD OF EXTERIOR DOORS AND WINDOWS TO BE
AT THE SAME HEIGHT ABOVE THE FINISH FLOOR U.N.O.
6. ALL EXTERIOR WALLS ARE 2x6, U.N.O.
7. ALL INTERIOR WALLS ARE 2x4, EXCEPT WHERE NOTED.
8. ANY MATERIAL IN CONTACT WITH CONCRETE SHALL
BE PRESSURE TREATED.
9. ALL MATERIAL BELOW FLOOD SHALL BE NON-SOLUBLE
MATERIAL.
10. CONTRACTOR AND SUBS SHALL REVIEW PLANS PRIOR
TO CONSTRUCTION. CONTACT DESIGNER IF QUESTIONS
ARISE BEFORE BUILDING.
11. PROVIDE INSULATION BEHIND ALL TUBS. INSTALL WITH
NO VOIDS.
12. 5/8" TYP "WR & X" AT CLG OF GARAGE
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A2.2
1/4" = 1'-0"1 SECOND FLOOR F.F.
ATTACHMENT 7
Page 24
Section VII. Item #1.
1' - 2 1/4"
1' - 2 1/4"
1' - 2 1/4"
12 1/8" / 12"
12" / 12"
12" / 12" 12" / 12"
12" / 12" 12" / 12" 12" / 12"
12" / 12"
12" / 12"
3 1/4" / 12"
3 1/4" / 12"
3" / 12"
3" / 12"
3" / 12"
10" / 12"
10" / 12"
3" / 12"3" / 12"
10" / 12"
10" / 12"
3" / 12"
7" / 12"
7" / 12"
7" / 12"
7" / 12"
RIDGE
RIDGERIDGE
RIDGE
RIDGE
RIDGE
RIDGE
ROOF
BREAK
V ALLEY
V ALLEY
V ALLEY
V ALLEY
ROOF
KICK
OUT
ROOF
KICK
OUT
ROOF BREAK
ROOF BREAK
ROOF BREAK
ROOF BREAK ROOF BREAKROOF BREAK ROOF BREAK
ROOF BREAKROOF BREAKROOF BREAK
5 1/2"
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C. 2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C. 2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2 X 8 RAFTERS
16" O.C.
2' - 8"
3' - 4"
8 1/2"
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A2.3
NOTE:
ALL RIDGES ARE TO BE CONTINUOUS MEMBERS WHERE POSSI BLE
USING AVAILABLE STANDARD LUMBER SIZES
1/4" = 1'-0"1 ROOF PLAN
ATTACHMENT 7
Page 25
Section VII. Item #1.
FLASHING NOTES:
1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METAL S TO
PREVENT GALVANIC REACTION.
2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL
WINDOWS AND DOORS.
3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT
ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN
ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING
CODE.
HARDIE HORIZONTAL PLANK SIDING
FIBERGLASS ARCHITECTURAL SHINGLES
TABBY STUCCO
5V METAL ROOF
LEGENDROOFWALL
FIRST LEVEL F.F. FIRST LEVEL F.F.
SECOND FLOOR F.F. SECOND FLOOR F.F.
FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT.
APPROXIMATE LINE OF FINISH GRADE
SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT.
9' - 1 1/8"10' - 1 1/8" 1' - 4 3/4"
5' - 8 3/4"6' - 5"5' - 8 3/4"
24' - 5 31/32"
LIVING
PLANT
WALL
BOARD & BATT SIDING
P.T. WOOD 36" HT. RAILING
10" SQ. LOW COUNTRY COLUMN
1X4 & 1X8 HARDIE FASCIA, TYP.
SLOPED 2X4 ON 1X8
WATERTABLE
2X8 JOIST TRELLIS
REFER TO /1 A4.3TABBY STUCCO ON
FOUNDATION WALL
TABBY STUCCO
TABBY STUCCO GOTHIC
CHIMNEY CAP
18"X36" DECORATIVE
WOOD GABLE VENT
12 x10 BEAM
HARDIE TRIM
5/4X8,BEVELED TOP
EDGE 10 x 12 BEAM
BOARD & BATT SIDING
10" SQ. COLUMN FOOTINGS
W/ BRICK FACADE
12"
12"
3"
12"
3 1/4"
12"
3" / 12"
10" / 12"
7" / 12"
9' - 2 7/8"
2
A4.3
1
A4.1
4' - 0"
---
-1
A4.2
3'-2"
A4.4
2
3
A4.4
4
A4.1
36" HT HANDRAIL PER CODE
-
---
4 1/2
" 4 1/2
"
12 " / 12"
12 " / 12" 12 " / 12"
12 " / 12"
CLCL
4' - 0"
9' - 1 1/8"1' - 4 3/4"10' - 1 1/8"
8' - 0"
11' - 9 3/4"
8' - 0"
1ST FL 26.00'
NAVD88
1ST FL 26.00'
NAVD88
AVER. ADJ. SIDEWALK GRADE =
22.96'
3' - 4 27/32"
PORCH ELEV 25.917
2' - 6"
GRADE 23.00
STANDING SEAM METAL ROOFING
F
A
E E E
F F3 1 2
1' - 6"
3'-0"
1' - 6"
3'-0"
5
A4.1
FIRST LEVEL F.F. FIRST LEVEL F.F.
SECOND FLOOR F.F. SECOND FLOOR F.F.
FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT.
SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT.
1ST FL NAVD88
GAR NAVD88
1ST FL NAVD88
GAR NAVD88
APPROXIMATE LINE OF FINISH GRADE 12" SQ. COLUMN FOOTINGS
W/ BRICK FACADE
12" SQ. COLUMN FOOTINGS
W/ BRICK FACADE
TABBY STUCCO ON
FOUNDATION WALL
TABBY STUCCO
METAL CHIMNEY CAP
18"X36" DECORATIVE
WOOD GABLE VENT
18"X36" DECORATIVE
WOOD GABLE VENT
WWNDW HD. HT.
8' - 0"
10' - 1"
1X4 & 1X8 HARDIE FASCIA, TYP.
5/4X6 HARDIE FRIEZE BOARD, TYP.
STANDING SEAM METAL ROOFING
10" SQ. LOW COUNTRY COLUMN
<varies>
SLOPED 2X4 ON 1X8
WATERTABLE
WNDW. HD. HT.
7' - 0"
7" / 12"
10" / 12"
10" / 12"
7" / 12"
3" / 12"
3 1/4"
12"
3"
12"
12"
12"
4' - 0"
1' - 9"
3' - 1"
4' - 0"
---
-1
A5.2
A4.4
1
2' - 8"
HARDIE PLANK
BOARD AND BATTEN
12" O.C.
1 X 4 HARDIE PLANK FASCIA
1 X 8 HARDIE PLANK FASCIA
PREFINISHED ROOF METAL EDGING
8" X 8" LOW COUNTRY COLUMN
C C B C C C C C
EEE
10' - 1 1/8" 1' - 4 3/4" 9' - 1 1/8"
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A3.1
1/4" = 1'-0"1 FRONT ELEVATION
1/4" = 1'-0"2 REAR ELEVATION
ATTACHMENT 7
Page 26
Section VII. Item #1.
FLASHING NOTES:
1. PROVIDE ISOLATION MATERIAL BETWEEN DISSIMILAR METAL S TO
PREVENT GALVANIC REACTION.
2. PROVIDE PREFINISHED CONCEALED METAL FLASHING AT ALL
WINDOWS AND DOORS.
3. PROVIDE PREFINISHED OR CONCEALED METAL FLASHING AT
ROOF TO WALL APPLICATIONS. IF WALL IS RUNNING AT AN
ANGLE, PROVIDE STEP FLASHING. INSTALL PER BUILDING
CODE.
FIRST LEVEL F.F. FIRST LEVEL F.F.
SECOND FLOOR F.F. SECOND FLOOR F.F.
FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT.
SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT.
STANDING SEAM METAL ROOFINGSTANDING SEAM METAL ROOFING
HOG BOARD UNDERPENNING
TABBY STUCCO
MASONRY CHIMNEY CAP
10" SQ. LOW COUNTRY COLUMN
P.T. 36" HT. WOOD RAILING
APPROXIMATE LINE OF FINISH GRADE 12" SQ. COLUMN FOOTINGS
W/ BRICK FACADE
10' - 1"
1X4 & 1X8 HARDIE FASCIA, TYP.
5/4X6 HARDIE FRIEZE BOARD, TYP.
3 1/4" / 12"
3"
12"
3"
12"
10"
12"
10' - 1"
10' - 1"
6 1/2"
2' - 11"
2' - 10"
4' - 10" 5' - 0" 2' - 10" 4' - 4" 4' - 4" 2' - 10" 4' - 11 3/4" 4' - 10 1/4"
1ST FL 26.00'
NAVD88
1ST FL 26.00'
NAVD88
4 1/2"
HARDIE PLANK
BOARD AND BATTEN
12" O.C.
1 X 4 HARDIE PLANK FASCIA
1 X 8 HARDIE PLANK FASCIA
1 X 4 HARDIE PLANK FASCIA
1 X 8 HARDIE PLANK FASCIA
PREFINISHED ROOF METAL EDGING
6' - 0 1/2"
---
-1
A4.4
9' - 1 1/8"1' - 4 3/4"10' - 1 1/8"
24' - 5 31/32"
ROOF
HT
FIRST LEVEL F.F. FIRST LEVEL F.F.
SECOND FLOOR F.F. SECOND FLOOR F.F.
FIRST LEVEL PLATE HT. FIRST LEVEL PLATE HT.
APPROXIMATE LINE OF FINISH GRADE
SECOND FLOOR PLATE HT. SECOND FLOOR PLATE HT.
TABBY STUCCO ON
FOUNDATION WALL
TABBY STUCCO
12" SQ. COLUMN FOOTINGS
W/ BRICK FACADE
P.T. WOOD 36" HT. RAILING SLOPED 2X4 ON 1X8
WATERTABLE
STANDING SEAM METAL ROOFING1X4 & 1X8 HARDIE FASCIA, TYP.
5/4X6 HARDIE FRIEZE BOARD, TYP.
3"
12"
10"
12"
3"
12"
2
A4.2
A4.3
3
TABBY STUCCO GOTHIC
CHIMNEY CAP
9' - 3 1/8"
12 " / 12" 12 " / 12"
5
A4.4
3' - 4"
4 1/2" 4 1/2"
4 1/2"
HARDIE PLANK
BOARD AND BATTEN
12" O.C.
1 X 4 HARDIE PLANK FASCIA
1 X 8 HARDIE PLANK FASCIA
PREFINISHED ROOF METAL EDGING
---
-1
A4.4
HARDIE PLANK
BOARD AND BATTEN
12" O.C.C
5
C G
9' - 1 1/8"1' - 4 3/4"10' - 1 1/8"
1ST FL 26.00'
NAVD88
1ST FL 26.00'
NAVD88
8"
8" X 8" LOW COUNTRY COLUMN
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A3.2
1/4" = 1'-0"1 RIGHT ELEVATION
1/4" = 1'-0"2 LEFT ELEVATION
ATTACHMENT 7
Page 27
Section VII. Item #1.
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A3.3
1 3D FRONT VIEW 12 3D FRONT VIEW 2
3 3D REAR VIEW 14 3D REAR VIEW 2
ATTACHMENT 7
Page 28
Section VII. Item #1.
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
ROOF PLAN
SECOND FLOOR PLATE HT.
1' - 4 3/4" 9' - 1 1/8"
9' - 2 7/8"
4 5/8"
1' - 4 3/4"
9' - 9 21/32"
DINING ROOM TO
KITCHEN
DOOR TO ATTIC AT
FRONT
UPSTAIRS LOFT
UNFINISHED
3 " / 12"
1 0" / 12"
3 " / 12"
1 0" / 12"
A4.1
4
1ST FL 26.00'
NAVD88
1"PORCH ELEV 25.917
2' - 6"
AVER. ADJ. SIDEWALK GRADE =
22.96'2' - 11 15/32"
36" HT PT HANDRAIL -1.25" X
1.25" PT PICKETS
(2)5/4 X 6 PT TREADS/1 X PT
RISERS/2 X 12 CARRIAGES
1X8 HARDIE PLANK SHEET
WITH 1 X 3 HP BATTEN
STRIP @16" O.C.
STANDING SEAM METAL ROOFING
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
10' - 1"
10' - 1 1/8"
3 1/4" / 12"
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
SIMPSON HOLDDOWN
CORNERS AS REQUIRED
LOW PROFILE GALV. PREFINISHED
METAL DRIP EDGE
1 X 4 S4S HARDIE TRIM + BLOCKING
1 X 6 BEADED #1 SYP SOFFIT PANEL
2X8 SUB FASCIA
1 X 6 S4S HARDIE TRIM + BLOCKING
30 YR. ARCHITECTURAL FIBERGLASS ASPHALT
ROOF SHINGLE OR APPROVED EQUAL 15# ASPH.
ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @
16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO
ASTM-D 7158-07 "H" SHINGLES.
2X6 CJ OR AS NOTED
@ 16" O.C.
2 X 6 WD. P.T. MUD SILL
SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR
BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION.
ATTACH IN STRICT COMPLIANCE W/
MANUFACTURER & ENGINEERS SPECIFICATIONS.
ALL STRAPPING DESIGN BY
ENGINEER
ANY WOOD TOUCHING CONCRETE OR
BELOW FLOOD SHALL BE PRESSURE TREATED
(PT)
APPROXIMATE LINE OF FINISHED GRADE.
GRADE AWAY FROM HOUSE
CONTRACTOR TO HAVE FRAMING
SYSTEM DESIGNED BY SUPPLIER AND
REVIEWED BY STRUCTURAL ENGINEER
PRIOR TO ORDER AND INSTALLATION.
RAFTER BEARING
OVER HANG
5/4" X 6" PT DECKING
2 X 8 PT FLR JST @ 16"
O.C. W/ JOIST HANGER
4" BRICK VENEER PIER WITH CMU
CENTER
7 1/4"
1 X 8 S4S HARDIE TRIM + BLOCKING
16"
1"
10' - 10 1/4"
TOP OF COLUMN
1 X 6 BEADED #1 SYP SOFFIT PANEL
2' - 11 15/32"
1ST FL 26.00'
NAVD88
AVER. ADJ. SIDEWALK GRADE =
22.96'
PORCH ELEV 25.917
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
8"
12 " / 12"
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
1 X 4 S4S HARDIE TRIM + BLOCKING
2X8 SUB FASCIA
1 X 6 S4S HARDIE TRIM + BLOCKING
2X6 CJ OR AS NOTED
@ 16" O.C.
SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR
BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION.
ATTACH IN STRICT COMPLIANCE W/
MANUFACTURER & ENGINEERS SPECIFICATIONS.ALL STRAPPING DESIGN BY
ENGINEER
ANY WOOD TOUCHING CONCRETE OR
BELOW FLOOD SHALL BE PRESSURE TREATED
(PT)
APPROXIMATE LINE OF FINISHED GRADE.
GRADE AWAY FROM HOUSE
CONTRACTOR TO HAVE FRAMING
SYSTEM DESIGNED BY SUPPLIER AND
REVIEWED BY STRUCTURAL ENGINEER
PRIOR TO ORDER AND INSTALLATION.
OVER HANG
1 X 8 S4S HARDIE TRIM + BLOCKING
1'-0"
2" 9' - 3 1/8"
(3) 2 X 12 #2 SYP W/ 1/2 PLYWOOD BOX BEAM
1/2" HARDIE PLANK PANELS
2 X 6 PLATE CONT.
2 X6 LEDGER
1 X 6 HARDIE
TRTIM FREIZE
ROOF BEYOND
---
-2
A4.1
1 X 6 BEADED #1 SYP SOFFIT PANEL
1 X 6 BEADED #1 SYP SOFFIT PANEL
10' - 1 1/8"
10' - 1 1/8" 1' - 4 3/4"
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
1' - 4 3/4"
10' - 1 1/8"
1 0" / 12"
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
SIMPSON HOLDDOWN
CORNERS AS REQUIRED
LOW PROFILE GALV. PREFINISHED
METAL DRIP EDGE
1 X 4 S4S HARDIE TRIM + BLOCKING
2X8 SUB FASCIA
1 X 6 S4S HARDIE TRIM + BLOCKING
30 YR. ARCHITECTURAL FIBERGLASS ASPHALT
ROOF SHINGLE OR APPROVED EQUAL 15# ASPH.
ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @
16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO
ASTM-D 7158-07 "H" SHINGLES.
16" TJI @ CJ OR AS NOTED
@ 16" O.C.
SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR
BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION.
ATTACH IN STRICT COMPLIANCE W/
MANUFACTURER & ENGINEERS SPECIFICATIONS.
ALL STRAPPING DESIGN BY
ENGINEER
ANY WOOD TOUCHING CONCRETE OR
BELOW FLOOD SHALL BE PRESSURE TREATED
(PT)
APPROXIMATE LINE OF FINISHED GRADE.
GRADE AWAY FROM HOUSE
CONTRACTOR TO HAVE FRAMING
SYSTEM DESIGNED BY SUPPLIER AND
REVIEWED BY STRUCTURAL ENGINEER
PRIOR TO ORDER AND INSTALLATION.
OVER HANG
5/4" X 6" PT DECKING
2 X 8 PT FLR JST @ 16"
O.C. W/ JOIST HANGER
1 X 8 S4S HARDIE TRIM + BLOCKING
---
-2
A4.1
2'-0"
R19 BATT INSULATION
3/4" ADVANTECH UNDERLAYMENT SCREWED
AND GLUED
(3) 2 X 12 #2 SYP W/ 1/2 PLYWOOD BOX BEAM
1ST FL 26.00'
NAVD88
1 X 6 BEADED #1 SYP SOFFIT PANEL
1 X 6 BEADED #1 SYP CEILING
10' - 1 1/8"
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
SECOND FLOOR PLATE HT.
1ST FL 26.00'
NAVD88
1"
9' - 1 1/8"1' - 4 3/4"10' - 1 1/8"
A4.1
4
SimA4.2
1
Sim
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A4.1
1/4" = 1'-0"1 BUILDING CROSS SECTION1
3/4" = 1'-0"2 FRONT PORCH SECTION
3/4" = 1'-0"3 LEFT SIDE PORCH 3/4" = 1'-0"4 LIVING ROOM PORCH
1/4" = 1'-0"5
ELEVATION/SECTION OF LEFT WING AT
FRONT PORCH
ATTACHMENT 7
Page 29
Section VII. Item #1.
5/8"
rebar
5/8"
rebar
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
GARAGE LEVEL F.F.
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
12 " / 12"
SIMPSON HOLDDOWN
CORNERS AS REQUIRED
LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE
1 X 8 S4S HARDIE FASCIA CONT.
1 X 4 S4S HARDIE TRIM + BLOCKING
2X8 SUB FASCIA
1 X 6 S4S HARDIE TRIM + BLOCKING
30 YR. ARCHITECTURAL FIBERGLASS ASPHALT
ROOF SHINGLE OR APPROVED EQUAL 15# ASPH.
ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @
16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO
ASTM-D 7158-07 "H" SHINGLES.
R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C.
R19 OPEN CELL FOAM
@ RAFTER DECK
1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK
WRAP" ON ENTIRE EXTERIOR, NAIL SHEATHING IN
ACCORDANCE W/ IRC 2021 & ICC-600 HIGH WIND
STANDARDS. FIRST SHEET TO BE P.T.
1X8 HARDIE PLANK SHEET WITH 1
X 3 HP BATTEN STRIP @16" O.C.
1/2" GYP.
BOARD
2X10 CJ OR AS NOTED
@ 16" O.C.
2 X 6 WD. P.T. BOTTOM PLATE CONT.
ALL STRAPPING DESIGN BY ENGINEER
CONTRACTOR TO HAVE FRAMING
SYSTEM DESIGNED BY SUPPLIER AND
REVIEWED BY STRUCTURAL ENGINEER
PRIOR TO ORDER AND INSTALLATION.
SEE SECTIONS FOR RAFTER BEARINGS
SIMPSON GALV. METAL HOLD-DOWN W/ 5/8" ANCHOR
BOLT. LOCATE HOLD-DOWN AS PER PLAN LOCATION.
ATTACH IN STRICT COMPLIANCE W/
MANUFACTURER & ENGINEERS SPECIFICATIONS.
4" THICK, 3000 P.S.I. CONCRETE SLAB REINF. W/
6x6 #10/#10 W.W.M. OR FIBERGLASS ON CLEAN, DRY,
TREATED, TERMITE COMPACTED EARTH FILL
2X6 PURLINS-CUT BETWEEN WOOD STUDS 48" O.C.
FOR PLYWOOD SHEATHING REQUIREMENTS.
ALL
STRAPPING
DESIGN BY
ENGINEER
ANY WOOD
TOUCHING CONCRETE
OR BELOW FLOOD
SHALL BE PRESSURE
TREATED (PT)
APPROXIMATE LINE OF FINISHED GRADE.
GRADE AWAY FROM HOUSE
CONTRACTOR TO HAVE FRAMING
SYSTEM DESIGNED BY SUPPLIER AND
REVIEWED BY STRUCTURAL ENGINEER
PRIOR TO ORDER AND INSTALLATION.
R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C.
1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP"
ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE
W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST
SHEET TO BE P.T.
1/2" EXTERIOR SHEATHING
FIRST COURSE TRTD
1X8 HARDIE PLANK SHEET WITH 1 X 3 HP
BATTEN STRIP @16" O.C.
COPPER METAL DRIP ON CHAMFERED 2X
& 1X 8 TRIM BOARD CONT.
MECHANICALLY FASTENED TO FOUNDATION
4"
see struc' dwgs
1' - 4"
1' - 9"
2' - 0" 13' - 0 1/4"
RAFTER BEARING
10' - 1 1/8" 1' - 4 3/4"
10"
1 SHEET 3/4 PLYWOOD AT GABLE
END2' - 1"
OVER HANG
A4.2
3
3 1/4"
3 0.00°
5 11/16"
1 X 6 BEADED #1 SYP SOFFIT PANEL
FIRST LEVEL F.F. FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
11' - 5 7/8"
10' - 1 1/8"
RAFTER BEARING
12 " / 12"---
-1
A4.2
SIM.
---
-
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
1
A4.2
SIM.
FIRST LEVEL F.F.
COPPER METAL DRIP ON CHAMFERED 2X
& 1X 8 TRIM BOARD CONT.
MECHANICALLY FASTENED TO FOUNDATION
3 0.00°
1 3/4"
1"
5/4 X 8 PT MECHANICALLY
FASTENED TO FOUNDTAION
Level 27
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A4.2
NOTES:
ALL STRUCTURAL MEMBERS & ANY EXTERIOR
MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) W IND LOAD &
MEET OR EXCEED ALL BUILDIING CODES INCLUDING IRC 20 121
W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODE S.
CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPL IER AND
REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND
INSTALLATION.
ALL STRAPPING DESIGN BY ENGINEER.
3/4" = 1'-0"1 LAUNDRY ROOM WALL SECTION
3/4" = 1'-0"2 MASTER BATH WALL SECTION 2
3" = 1'-0"3 TYPICAL WATER TABLE
ATTACHMENT 7
Page 30
Section VII. Item #1.
5/8"
rebar
FIRST LEVEL F.F.
5' - 0"
FIRST LEVEL F.F.
SECOND FLOOR F.F.
FIRST LEVEL PLATE HT.
GARAGE LEVEL F.F.
SECOND FLOOR PLATE HT.
9' - 1 1/8"
7' - 2 31/32"
8' - 0"
7 1/4"
1' - 8 3/4"
closet
@ stairs
7' - 8 29/32"
9' - 1 1/8"
LIVING PLANT
WALL SEE SPEC
SHEET- A4.3
13' - 1 1/8"
4' - 0 1/2"
RAFTER BEARING @ STAIRCASE
NOTE:
1) RAFTER NOTCH NOT TO EXCEED 25%
2) FIRE CUT NOT TO EXCEED 1/3 OF
RAFTER PER CODE
SIMPSON HOLDDOWN
CORNERS AS REQUIRED
LOW PROFILE GALV. PREFINISHED METAL DRIP EDGE
1 X 8 S4S HARDIE FASCIA CONT.
1 X 4 S4S HARDIE TRIM + BLOCKING
2X8 SUB FASCIA
1 X 6 S4S TRIM + BLOCKING
30 YR. ARCHITECTURAL FIBERGLASS ASPHALT
ROOF SHINGLE OR APPROVED EQUAL 15# ASPH.
ROOFING FELT ON 1/2 " OSB PLY ON 2X8 RAFTERS @
16" O.C. EXCEPT AS NOTED . NAIL MUST CONFORM TO
ASTM-D 7158-07 "H" SHINGLES.
R19 OPEN CELL FOAM
@ RAFTER DECK
APPROXIMATE LINE OF FINISHED GRADE.
GRADE AWAY FROM HOUSE
R-19 INSULATION BETWEEN 2 X6 WD. STUDS @ 16" O.C.
1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP"
ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE
W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST
SHEET TO BE P.T.
1/2" EXTERIOR SHEATHING
FIRST COURSE TRTD
1X8 HARDIE PLANK SHEET WITH 1
X 3 HP BATTEN STRIP @16" O.C.
METAL DRIP ON CHAMFERED 2X
& 1X10 TRIM BOARD CONT.
MECHANICALLY FASTENED TO FOUNDATION
3 " / 12"
1 0" / 12"
TEMPERED WINDOW AS
SPECIFIED
HANDRAIL AT 36" HT
ABOVE TREADS PER
CODE
7 1/4"
5/8" TYPE X GYPSUM
WOOD STAIRS PER
CODE
UP
UP
WOOD OVER
LANDING
4' - 11 25/32"
10' - 1 1/8" 1' - 4 3/4"2' - 0"
Level 25
Level 27
1 X 6 BEADED #1 SYP SOFFIT PANEL
7 1/4"
8' - 4 11/32"
1/2" GYPSUM
ROOF PLAN
3' - 4"
6"
1"
2 5/16"
6"
1/16"
4'-0"
GOTHIC ARCH MASONRY CHIMNEY CAP
NARROW SIDE
2'-8"
CHIMNEY TERMINATION CAP(BY
MANUFACTURER)
MASONRY WASH
3/4" X 6" TABBY STUCCO
TRIM7 11/32"
8 21/32"
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
Designer
Author
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A4.3
NOTES:
ALL STRUCTURAL MEMBERS & ANY EXTERIOR
MATERIAL SHALL MEET OR EXCEED A 150 M.P.H. (MIN.) W IND LOAD &
MEET OR EXCEED ALL BUILDIING CODES INCLUDING IRC 20 21
W/SOUTH CAROLINA AMENDMENTS & 2009 IECC ENERGY CODE S.
CONTRACTOR TO HAVE FRAMING SYSTEM DESIGNED BY SUPPL IER AND
REVIEWED BY STRUCTURAL ENGINEER PRIOR TO ORDER AND
INSTALLATION.
ALL STRAPPING DESIGN BY ENGINEER.
3/4" = 1'-0"1 TRELLIS DETAIL
3/4" = 1'-0"2 STAIR SECTION
3/4" = 1'-0"3
MASONRY TABBY STUCCO CHIMNEY
CAP
ATTACHMENT 7
Page 31
Section VII. Item #1.
ELEVATION
PLAN SECTION
OPTIONAL 2X6" CAP
2"X6" PRESSURE TREATED #2
VARIES
2X4" STRINGER
6"X6" POST
2X4" STRINGEROPTIONAL 2X6" CAP
6X6" POSTS SPACED 8' ON CENTER
8' SHADOWBOX FENCE SECTIONS
VERTICAL FENCING
1"X6" PRESSURE TREATED #2
6"X6" PRESSURE TREATED PINE POSTS
2X4" STRINGER UNDER CAP
FINISHED GRADE
3 - 2X4" PRESSURE TREATED STRINGERS
6" X 6" PRESSURE TREATED PINE #2 POST
6' - 0"
CONCRETE FOOTING
4"
18"MIN
VERTICAL FENCING
1"X6" PRESSURE TREATED #2
VERTICAL FENCING
1"X6" PRESSURE TREATED #2
FIRST LEVEL F.F.
GARAGE LEVEL F.F.
Level 27
FIRST LEVEL F.F.
GARAGE LEVEL F.F.
2 X 6 PT TOP RAIL W/
5/4 GRAB RAIL
3/4"
1.5" X 1.5" PT BALUSTERS
1 X 4 PT SIDE BOARD
1 X 4 PT SIDE BOARD
6 X 6 PT NEWEL
OVER THE POST
RAIL
2 X 12 PT CARRIAGE AND
TREADS
12" X 12" X 12"CONCRETE
FOOTING
Level 27
FIRST LEVEL F.F.
2 X 6 PT TOP RAIL W/
5/4 GRAB RAIL
1.5" X 1.5" PT BALUSTERS
1 X 4 PT SIDE BOARD
1 X 4 PT SIDE BOARD
2 X 6 BACK BOARD TO
WALL
Level 27
2 X 6 #2 SYP STUD WALL WITH
R-19 BATT INSULATION
1/2" OSB PLYWOOD SHEATHING W/ DUPONT "TYVEK WRAP"
ON ENTIRE EXTERIOR, NAIL SHEATHING IN ACCORDANCE
W/ IRC 2021 & ICC-600 HIGH WIND STANDARDS. FIRST
SHEET TO BE P.T.
1" X 3" HARDIE PLANK BATTEN STRIP
OVER 7/16" HARDIE PLANK SHEET
MATERIAL
2 X 6 ENERGY CORNER
9 1/2"
SIMPSON HOLD-DOWN PER
STRUCTURAL ENGINEER
FIRST LEVEL F.F.
GARAGE LEVEL F.F.
TOP OF POOL
THICKNESS BY POOL CONTRACTOR
5' - 6"
WATER LINE
RAMP
1"
5'4 x 6 PT DECKING
1 X 3 PT EDGING
1 X 6 PT BAND
1 X 10 PT BAND
2 X 12 FLR JOISTS @@ 16" O.C.
1 X 4 PT BAND
2 X 4 PT TOP PLATE
2 X 4 VERTICAL FRAME
2 X 4 PT BOTTOM PLATE
1 X 6 PT HORIZONTAL BOARD
2 X PT BLOCKING
2 X PT BLOCKING
BLACK GALV. HARDWARE CLOTH
1" 1"
2 X PT MUD SILL
1 X 4 PT BAND
-
---
Sim6A
A4.4
SECTION 6A/A4.4
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A4.4
3/4" = 1'-0"1 SERVICE YARD DETAILS
3/4" = 1'-0"2 STAIR-HANDRAIL DETAIL
3/4" = 1'-0"3 HANDRAIL SECTION
1 1/2" = 1'-0"4 TYPICAL CORNER SECTION
1/2" = 1'-0"5 POOL SECTION
3/4" = 1'-0"6 HOG BOARD UNDERPINNING DETAIL
OLD WORLD TABBY PAVERS
ATTACHMENT 7
Page 32
Section VII. Item #1.
ALL WINDOW SIZES ARE NOMINAL. CONTRACTOR TO VERIFY ALL ROUGH OPENINGS.
ALL GLASS TO BE LOW E GLASS. WINDOW SUPPLIER SHALL CONFORM TO ALL CODES DESIGNATED.
TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CO DE. CONTACT DESIGNER IF ANY
DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL WINDOW S SHALL MEET THE ENERGY STAR
GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE
NOTE
ALL DOOR SIZES ARE NOMINAL. CONTRACTOR TO VERIFY RO UGH OPENINGS.
ALL GLASS TO BE LOW E GLASS. DOOR SUPPLIER SHALL CO NFORM TO ALL CODES DESIGNATED.
TEMPERED GLASS SHALL BE INSTALLED AS DICTATED BY CO DE. CONTACT DESIGNER IF ANY
DISCREPANCIES ARE FOUND BEFORE ORDERING. ALL DOORS SHALL MEET THE ENERGY STAR
GUIDELINES AS A MINIMUM SUPPLIER TO FURNISH BUILDER WITH R.O. SCHEDULE
NOTE
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A5.0
WINDOW SCHEDULE
SYM. Width Height Description DP RATING U-FACTOR SHGC
A 2' - 7 1/2" 4' - 11 3/4" 3260 FIBERGLASS CLAD DBHG M ARVIN ELEVATE W/ LOW E GLASS AND SDL
MUNTINS
40/45 .29 .29
B 2' - 7 1/2" 4' - 3 3/4" 3252 FIBERGLASS DBHG MARVIN ELEVATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29
C 2' - 7 1/2" 5' - 7 3/4" 3268 FIBERGLASS DBHG MARVIN ELEVATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29
D 2' - 5 1/2" 3' - 11 3/4" 3048 FIBERGLASS DBHG MARVIN ELEVATE W/LOW E GLASS - SDL MUNTINS 40/45 .29 .29
E 2' - 8" 4' - 7 1/8" 3371 FIBERGLASS CSMT MARVIN ELEV ATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29
F 2' - 11 1/2" 5' - 0" 3252 FIBERGLASS DBHG MARVIN ELE VATE W/LOW E GLASS - SDL MUNTINS 40/45 .29 .29
G 2' - 0" 3' - 11 1/8" 2547 FIBERGLASS CSMT MARVIN ELE VATE W/ LOW E GLASS AND SDL MUNTINS 40/45 .29 .29
DOOR SCHEDULE
Tag
Number
Door Size
Door Type DESCRIPTION DP RATING U-FACTOR SHGC Width HeightThickness
1 5' - 11" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN PR 3/0 FR DOOR W/ SDL AND LOW E GLASS 40/45 .29 .29
2 2' - 0" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN FR DO OR W/ SDL AND LOW E GLASS 40/45 .29 .29
3 2' - 0" 7' - 11 1/2" 1 3/4" METAL CLAD MARVIN FR DO OR W/ SDL AND LOW E GLASS 40/45 .29 .29
4 3' - 0" 8' - 0" 1 3/4" 3/4 GLASS OVER SINGLE PANEL MA HOGANY DOOR- SDL LOWE GLASS 40/45 .29 .29
5 2' - 8" 8' - 0" 1 3/4" 6 PANEL FIBERGLASS DOOR EXTERI OR DOOR UNIT 40/45 .29 .29
6 2' - 8" 8' - 0" 1 3/4" 6 PANEL METAL DOOR UNIT REINFO RCE FRAME
7 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT
8 2' - 0" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
9 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
10 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
10A 3' - 0" 8' - 0" 0" CASED OPENING
11 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
12 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
13 3' - 0" 8' - 0" 0" CASED OPENING
14 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT
15 2' - 8" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
16 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
17 2' - 6" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT
18 2' - 0" 8' - 0" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
19 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE POCKET DOOR UNIT
20 2' - 8" 5' - 0" 1 3/8" 4 PANEL MDF SOLID CORE UNIT C UT DOWN
21 2' - 8" 6' - 8" 1 3/8" 6 PANEL MDF SOLID CORE UNIT
22 2' - 8" 5' - 0" 1 3/8" 4 PANEL MDF SOLID CORE UNIT C UT DOWN
WINDOWS ARE MARVIN ELEVATE
ATTACHMENT 7
Page 33
Section VII. Item #1.
DOUBLE HUNG
WINDOW AS SPEC'D
1/2" GYPSUM BOARD
1/4" SHIM SPACE
(3) 2X6
2X6 STUD WALL W/
R-19 INSULATION
1/2" OSB SHEATHING W/ "TYVEK" HOUSE
WRAP ON ENTIRE EXTERIOR, NAIL
SHEATHING ACCORDANCE W/ 2021 IRC &
ICC 600 HIGH WIND STANDARDS
5/4 X 6 S4S HARDIE PLANK
EDGE OF SILL BELOW
1C
A5.1
SILL
SCALE: 3" = 1'-0"
1B
A5.1
MEETING RAIL
SCALE: 3" = 1'-0"
1A
A5.1
HEAD
SCALE: 3" = 1'-0"
1D
A5.1
JAMB
SCALE: 3" = 1'-0"
1/4" MARGIN (TYP) 1/4" MARGIN (TYP)
SHUTTER T&G V JT (1/2
WIDTH OF WINDOW
STAINLESS STEEL SHUTTER DOG HINGE
W/ BLACK POWDER COAT FINISH
1/2" OSB SHEATHING W/ "TYVEK" HOUSE
WRAP ON ENTIRE EXTERIOR, NAIL
SHEATHING ACCORDANCE W/ 2021 IRC
& ICC-600 HIGH WIND STANDARDS
2X6 STUD WALL W/ R-19 INSULATION
1/2" GYPSUM BOARD
HEADER AS SPEC'D
PRE-FINISHED ALUM. FLASHING
1/4" SHIM SPACE
BACKER ROD & CAULK
DOUBLE HUNG WINDOW AS SPEC'D
1/4" MARGIN (TYP)
DOUBLE HUNG WINDOW AS SPEC'D
1/4" SHIM SPACE
BACKER ROD & CAULK
3X2 S4S (EXACT SIZE) #1
P.T. DURAPINE SILL
PRE-FINISHED ALUM. FLASHING
(2) 2X6 CONT.
1/2" GYPSUM BOARD
1/2" OSB SHEATHING W/ "TYVEK" HOUSE
WRAP ON ENTIRE EXTERIOR, NAIL
SHEATHING ACCORDANCE W/ 2021 IRC
& ICC-600 HIGH WIND STANDARDS
2 3/4" 1/4"
3"
2X6 STUD WALL W/ R-19 INSULATION
1X8 HARDIE HORIZONTAL PLANK
SMOOTH CEMENTITOUS SIDING WITH
6-1/2" REVEAL
1X8 HARDIE HORIZONTAL
PLANK SMOOTH CEMENTITOUS
SIDING WITH 6-1/2" REVEAL
1X8 HARDIE HORIZONTAL PLANK
SMOOTH CEMENTITOUS SIDING WITH
6-1/2" REVEAL
SILICONE SEALANT
3/4" CAP
RB 60 CROWN MOLDING
1 X 3-1/2 S4S TRIM
RB 273 PICTURE MOLD
1X3 S4S TRIM BOARD
1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE
5/4 X 6 S4S HARDIE W/ 5-1/2" EXPOSURE
DOUBLE HUNG WINDOW DETAIL
SCALE: 1"= 1'-0"
1
A5.1
1C
A5.1
1B
A5.1
1D
A5.1
1A
A5.1
1 1/2"5 1/2"
SEE WINDOW SCHEDULE
WINDOW HEIGHT3"
WINDOW
- SEE WINDOW SCHEDULE FOR MORE DETAILS
1 X 4 HARDIE PLANK TRIM
3 1/2"3 1/2"
3/4"
3/4"
SEE WINDOW SCHEDULE
WINDOW WIDTH
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
SAL
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A5.1
3" = 1'-0"2
WINDOW & SHUTTER DETAILS HARDIE
SIDING- 3" SCALE
1" = 1'-0"1
WINDOW & SHUTTER DETAILS - 1"
SCALE
ATTACHMENT 7
Page 34
Section VII. Item #1.
2C
A6.1
JAMB
SCALE: 1-1/2" = 1'-0"
1/4" SHIM SPACE
5/4 X 4-9/16 S4S
WOOD JAMB
RB-34 MOLDING STOP
CUSTOM WOOD
ENTRY DOOR / SIDELIGHT
1/2" GYPSUM BOARD
2X6 STUD WALL W/ 5-1/2" R-19
BATT INSULATION
1/2" OSB SHEATHING W/ "TYVEK" HOUSE
WRAP ON ENTIRE EXTERIOR, NAIL
SHEATHING ACCORDANCE W/ 2021 IRC
AND ICC 600 HIGH WIND STANDARDS
5/4 X 6 S4S WOOD #1
P.T. DURAPINE
EDGE OF SILL BELOW
(3) 2X6
A6.1
A6.1
CUSTOM WOOD ENTRY
DOOR/SIDELIGHT
RB-34 MOLDING STOP
FACTORY SILL
3/4" T&G PLYWOOD
2A HEAD
SCALE: 1-1/2" = 1'-0"
2B SILL
SCALE: 1-1/2" = 1'-0"
VERIFY R.O. W/ ENTRY DOOR MANF.
0' - 2 3/4"
0' - 0 3/8"0' - 2 3/8"
0' - 0 1/2"
0' - 2"
2C
A6.1
MULL
SCALE: 1-1/2" = 1'-0"
1/4" MARGIN (TYP)
1/4" MARGIN (TYP)
HEADER AS SPEC'D
PREFINISHED ALUM.
FLASHING
1 X 2 S4S #1 P.T. WOOD W/ 3/8" SLOPE
5/4 X 6 S4S WOOD #1 P.T. DURAPINE OR AZEK
W/ 5-1/2" EXPOSURE
1/4" SHIM SPACE
5/4 X 4-9/16 S4S
WOOD JAMB
RB-34 MOLDING STOP
CUSTOM WOOD ENTRY
DOOR / SIDELIGHT
1/4" MARGIN (TYP)
1X8 HARDIE SHEET WITH 1 X 3 HARDIE
BATTEN STRIPS
1X8 HARDIE HORIZONTAL PLANK SMOOTH
CEMENTITOUS SIDING WITH 6-1/2" REVEAL
2 x 8 PT FLOOR JOIST @16" O.C.
5 1/2"
1/4" SHIM SPACE
5/4 X 4-9/16 S4S
WOOD JAMB
RB-34 MOLDING STOP
CUSTOM WOOD
ENTRY DOOR / SIDELIGHT
1/2" GYPSUM BOARD
2X6 STUD WALL W/ 5-1/2" R-19
BATT INSULATION
1/2" OSB SHEATHING W/ "TYVEK" HOUSE
WRAP ON ENTIRE EXTERIOR, NAIL
SHEATHING ACCORDANCE W/ 2021 IRC
AND ICC 600 HIGH WIND STANDARDS
5/4 X 6 S4S WOOD #1
P.T. DURAPINE
EDGE OF SILL BELOW
(3) 2X6
1/4" MARGIN (TYP)
1/4" MARGIN (TYP)
1X8 HARDIE HORIZONTAL PLANK SMOOTH
CEMENTITOUS SIDING WITH 6-1/2" REVEAL
5 1/2"
FIRST LEVEL F.F.
-
---
-
---
-
---
2A
A6.1
A6.1
A6.1
2B
2C
4"
2"6"
2"6"7' - 11 1/2"
4"2' - 0 5/32"6"5' - 11 5/16"6"2' - 0 1/32"
11' - 7 1/2"
213
HARDIE PLANK OR
AZEK 3/4" X 4" TRIM
HARDIE PLANK OR
AZEK 5/4" X 6" TRIM
HARDIE PLANK OR
AZEK 2" X 2" TRIM W/
BEVEL EDGE
CONCEALED METAL
FLASHING
SIDING AS
SPECIFIED
HARDIE PLANK OR
AZEK 3/4" X 6
MULLION
1"
1"
4
A4.1
Level 27
5
A4.1
DESIGN FOR
Certified Professional Building Designer
A
B D
® Professional Member
of American Institute
of Building Design
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT
23 Plantation Park Drive
Bldg 100 -Suite 103
Bluffton SC 29910
Ph. 843.815.9575
Certified Green Professional
COPYRIGHT 2022 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
LOW TIDE DESIGNS HAS NOT BEEN
HIRED FOR CONSTRUCTION OR
OBSERVATION MANAGEMENT
06.04.2024
08.05.2024
12.09.2025
05.06.2026
FINAL-SUBMITTAL
INITIALS
OWNERS _______ BUILDER________
S. LIBERTI
MAB
24-033
05.01.2024GLENDA AND BILLY MIKULAK
LOT#2 X 2A " GREEN STREET"
BEAUFORT COUNTY, BLUFFTON SOUTH CAROLINA
A6.1
3/4" = 1'-0"2 FRONT DOOR ELEVATION
ATTACHMENT 7
Page 35
Section VII. Item #1.
OF 4 SHEET 1
Chk'd By:
Project ID:
Issue / Revision DescriptionNo.
Drawn Date:
Chk'd By:
Project ID:
Sheet No.
M. Brock
po box 358, port royal
south carolina, 29935
ph. 843.540.6407
mbrock@mbrockdesigns.com
J. M. BROCK
RLA
copyright © M. Brock, RLA all rights reserved
tS-101
Title Page
E
E
Drawn By: Drawn By:M. Brock
1
25004
Site Development Plans For
Mikulak Residence
95 Green St.
Bluffton, SC
10.08.25 2
SUBMITTAL
12/25
PROJECT NOTES:
Owner: Glenda Mikulak
Property Address: 95 Green St.
Property Lot Number: 2A
Tax ID Number: R610 039 00A 0347 0000
Property Area: 0.334 Acres
FLAT-BOTTOM TRENCH DETAILV-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
South Carolina Department of
Health and Environmental Control
South Carolina Department of
Health and Environmental Control
South Carolina Department of
Health and Environmental Control
STANDARD SPLIT-RAIL FENCE (TREE PROTECTION)
South Carolina Department of
Health and Environmental Control
DATE
SLOPE
INDIVIDUAL RESIDENTIAL LOT CONTROLS
LOT EXAMPLE "A"
SLOPES TO FRONT
LOT EXAMPLE "B"
SLOPES TO REAR
LOT EXAMPLE "C"
SLOPES TO SIDE
INDIVIDUAL LOTS
SLOPE
SLOPE
South Carolina Department of
Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of
Health and Environmental Control
DATE
PLAN SET KEY:
1- TS101-TITLE SHEET- NOTES- DETAILS
2- CS102 MOBILIZATION PLAN
4-CS103- GRADING & DRAINAGE PLAN
5-LS105- LANDSCAPE PLAN
GROUNDCOVER PLANTING DETAIL
MULTI-TRUNK TREE PLANTING DETAIL
SHRUB PLANTING DETAIL
3 TS101
N.T.S.
4 TS101
N.T.S.
5 TS101
TREE INSTALLATION DETAIL
N.T.S.
N.T.S.
6 TS101
SITE GRADING PLAN NOTES:
1.VERIFY ALL BUILDING SETBACKS, BUFFERS AND LOT LINES PRIOR TO
CONSTRUCTION. NO OFFSITE CONSTRUCTION IS PROPOSED.
2.CONSTRUCT DRIVEWAY AND SIDEWALKS TO ALLOW FOR DRAINAGE
FLOW CONSISTENT WITH EXISTING DRAINAGE CONDITIONS.
3.ALL SITE IMPROVEMENTS TO COMPLY WITH APPLICABLE CITY OF
BEAUFORT AND COMMUNITY REQUIREMENTS.
4.CONTRACTOR TO VERIFY SITE UTILITY AND STORM-WATER
REQUIREMENTS AND ENSURE PROPOSED DRAINAGE COMPLIES WITH
ANY PERMIT CONDITIONS. ALL CONSTRUCTION BMP's AND ANY
APPLICABLE SCDHEC-OCRM PERMITTING IS ASSUMED TO BE HANDLED
BY THE OWNER/CONTRACTOR DIRECTLY.
5.TREE PROTECTION REQUIRED ON ALL TREES TO BE MAINTAINED.
SEE DETAIL ON THIS PAGE. EXISTING TREES HAVE BEEN APPROVED
FOR GENERAL MAINTENANCE PRUNING FOR THE HEALTH OF THE TREES.
7. PROPOSED HOUSE FFE TO BE 26'-00". EXISTING GARAGE FLOOR
FFE 24'-00".
8. ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT
AFFECT NEIGHBORING PROPERTIES.
9. SILT FENCING SHALL BE INSTALLED IF CONSTRUCTION OF DRIVE
EXCEEDS A 48 HOUR PERIOD.
10. CONTRACTOR TO MAINTAIN STREET DRAIN INLETS DURING ENTIRE
CONSTRUCTION PHASE OF PROJECT UNTIL ALL GROUND COVER
ESTABLISHED.
11. A RAIN GARDEN IS NOT REQUIRED FOR THIS PHASE OF CELADON PER
COUNTY STORM WATER REQUIREMENTS FOR WATER QUALITY.
12. PLAN PREPARED USING THE FOLLOWING REFERENCES:
(A) M Brock Designs LLC- Site Plan, Mobilization, Grading Plan,
& Landscape Plan
(B)Surveying Consultants- Surveying
(C) Sam Liberti- Low Tide Designs- Architecture
TABBY CONCRETE APRON DETAIL
1 TS101
SECTION A-A'
ON COMPACTED BASE
CRUSHED GRANITE DRIVE 2 TS101
WIRE AND WOOD FENCE
LIVING FENCING - 31 LF / 1 Gates
"LIVING FENCE"N.T.S.
7 TS101
SITE COVERAGE:
Homesite SF Total:14,549 SF (0.33 Acs)
Building Footprint(s):Existing- 720 SF
Proposed-2,342 SF
Total:3,062 SF
Impervious: Existing- 501 SF (Drive)
Proposed- 1,788 SF (Gravel Drive, Landing, Pool
Total: 2,289 SF
Total Site Coverage:5,351 SF (36.7%)
Total Open Space: 9,198 SF (63.3%)
Disturbed Area:7,971 SF (0.18 Acs)
Site Coverage
ATTACHMENT 8
Page 36
Section VII. Item #1.
RAMP
23
OF 4 SHEET 2
Chk'd By:
Project ID:
Issue / Revision DescriptionNo.
Drawn Date:
Chk'd By:
Project ID:
Sheet No.
M. Brock
po box 358, port royal
south carolina, 29935
ph. 843.540.6407
mbrock@mbrockdesigns.com
J. M. BROCK
RLA
copyright © M. Brock, RLA all rights reserved
CS-102
Mobilization Plan E
E
Drawn By: Drawn By:M. Brock
1
25004
Site Development Plans For
Mikulak Residence
95 Green St.
Bluffton, SC
10.08.25 2
SUBMITTAL
12/25
MBDMOBILIZATION PLAN
1" =10'-0"
PROJECT NOTES:
Owner: Glenda Mikulak
Property Address: 95 Green St.
Property Lot Number: 2A
Tax ID Number: R610 039 00A 0347 0000
Property Area: 0.334 Acres
CONTRACTOR NOTE:
·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND
SHALL NOT AFFECT NEIGHBORING PROPERTIES.
STANDARD SPLIT-RAIL FENCE (TREE PROTECTION)
South Carolina Department of
Health and Environmental Control
DATE
SLOPE
INDIVIDUAL RESIDENTIAL LOT CONTROLS
LOT EXAMPLE "A"
SLOPES TO FRONT
LOT EXAMPLE "B"
SLOPES TO REAR
LOT EXAMPLE "C"
SLOPES TO SIDE
INDIVIDUAL LOTS
SLOPE
SLOPE
South Carolina Department of
Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of
Health and Environmental Control
DATE
FLAT-BOTTOM TRENCH DETAILV-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
South Carolina Department of
Health and Environmental Control
Proposed Tree
Protection
Proposed Tree
Protection
Proposed Tree
Protection
Proposed Silt Fence
Proposed Construction
Entrance
SITE COVERAGE:
Homesite SF Total:14,549 SF (0.33 Acs)
Building Footprint(s):Existing- 720 SF
Proposed-2,342 SF
Total:3,062 SF
Impervious: Existing- 501 SF (Drive)
Proposed- 1,788 SF (Gravel Drive, Landing, Pool
Total: 2,289 SF
Total Site Coverage:5,351 SF (36.7%)
Total Open Space: 9,198 SF (63.3%)
Disturbed Area:7,971 SF (0.18 Acs)
Site Coverage
ATTACHMENT 8
Page 37
Section VII. Item #1.
HOUSE
26'-00" AMSL
RAMP
15' x 35' POOL
RAMP
23
UP
DW
OVEN
ROBINS ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LNDRY/ENTRY
TILE FLR.
10' 1 1/8" CLG. HT.
M. CLST
WOOD FLR.
10'-1 1/8" CLG. HT.
M. BATH
TILE FLR.
10'-1 1/8" CLG. HT.
MASTER
BEDROOM
WOOD FLR.
10'-1 1 /8" CLG. HT.
PWDR
WOOD FLR.
10'-1 1/8" CLG. HT.
PANTRY
WOOD FLR.
10'-1 1/8" CLG. HT.
HALL
WOOD FLR.
10'-1 1/8" CLG. HT.
KITCHEN
WOOD FLR.
10'-1 1/8" CLG. HT.
D. ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
L. ROOM
WOOD-FLR.
10'-1 1/8" CLG. HT.
BATH #2
TILE FLR.
10' 1 1/8" CLG. HT.
CLOSET
WOOD FLR.
10' 1 1/8" CLG. HT.
SAFE ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
FRONT PORCH
T&G FLR.
SIDE PORCH
T&G P.T. FLR.
OF 4 SHEET 3
Chk'd By:
Project ID:
Issue / Revision DescriptionNo.
Drawn Date:
Chk'd By:
Project ID:
Sheet No.
M. Brock
po box 358, port royal
south carolina, 29935
ph. 843.540.6407
mbrock@mbrockdesigns.com
J. M. BROCK
RLA
copyright © M. Brock, RLA all rights reserved
CS-103
Grading & Drainage Plan
E
E
Drawn By: Drawn By:M. Brock
1
25004
Site Development Plans For
Mikulak Residence
95 Green St.
Bluffton, SC
10.08.25 2
SUBMITTAL
12/25
MBDGRADING & DRAINAGE PLAN
1" =10'-0"
PROJECT NOTES:
Owner: Glenda Mikulak
Property Address: 95 Green St.
Property Lot Number: 2A
Tax ID Number: R610 039 00A 0347 0000
Property Area: 0.334 Acres
TYPICAL BIORETENTION (Rain Garden)
CROSS SECTION
SITE GRADING PLAN NOTES:
1.VERIFY ALL BUILDING SETBACKS, BUFFERS AND LOT LINES PRIOR TO
CONSTRUCTION. NO OFFSITE CONSTRUCTION IS PROPOSED.
2.CONSTRUCT DRIVEWAY AND SIDEWALKS TO ALLOW FOR DRAINAGE
FLOW CONSISTENT WITH EXISTING DRAINAGE CONDITIONS.
3.ALL SITE IMPROVEMENTS TO COMPLY WITH APPLICABLE CITY OF
BEAUFORT AND COMMUNITY REQUIREMENTS.
4.CONTRACTOR TO VERIFY SITE UTILITY AND STORM-WATER
REQUIREMENTS AND ENSURE PROPOSED DRAINAGE COMPLIES WITH
ANY PERMIT CONDITIONS. ALL CONSTRUCTION BMP's AND ANY
APPLICABLE SCDHEC-OCRM PERMITTING IS ASSUMED TO BE HANDLED
BY THE OWNER/CONTRACTOR DIRECTLY.
5.TREE PROTECTION REQUIRED ON ALL TREES TO BE MAINTAINED.
SEE DETAIL ON THIS PAGE. EXISTING TREES HAVE BEEN APPROVED
FOR GENERAL MAINTENANCE PRUNING FOR THE HEALTH OF THE TREES.
7. PROPOSED HOUSE FFE TO BE 26'-00". EXISTING GARAGE FLOOR
FFE 24'-00".
8. ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND SHALL NOT
AFFECT NEIGHBORING PROPERTIES.
9. SILT FENCING SHALL BE INSTALLED IF CONSTRUCTION OF DRIVE
EXCEEDS A 48 HOUR PERIOD.
10. CONTRACTOR TO MAINTAIN STREET DRAIN INLETS DURING ENTIRE
CONSTRUCTION PHASE OF PROJECT UNTIL ALL GROUND COVER
ESTABLISHED.
11. A RAIN GARDEN IS NOT REQUIRED FOR THIS PHASE OF CELADON PER
COUNTY STORM WATER REQUIREMENTS FOR WATER QUALITY.
12. PLAN PREPARED USING THE FOLLOWING REFERENCES:
(A) M Brock Designs LLC- Site Plan, Mobilization, Grading Plan,
& Landscape Plan
(B)Surveying Consultants- Surveying
(C) Sam Liberti- Low Tide Designs- Architecture
Tree Canopy Coverage
TREE CANOPY CALCULATION:
Total Limit of Work Area:14,549 SF
Building Footprint: 3,336 SF
Remaining Site Area:11,213 SF
Mature Canopy Coverage: 11,290 SF
(Existing & Proposed)
%Canopy Coverage (75% MIn.)77.59 %
SITE COVERAGE:
Homesite SF Total:14,549 SF (0.33 Acs)
Building Footprint(s):Existing- 720 SF
Proposed-2,342 SF
Total:3,062 SF
Impervious: Existing- 501 SF (Drive)
Proposed- 1,788 SF (Gravel Drive, Landing, Pool
Total: 2,289 SF
Total Site Coverage:5,351 SF (36.7%)
Total Open Space: 9,198 SF (63.3%)
Disturbed Area:7,971 SF (0.18 Acs)
CONTRACTOR NOTE:
·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND
SHALL NOT AFFECT NEIGHBORING PROPERTIES.
Proposed Pool
By Others
Proposed Crushed
Granite Drive
(1,242 SF)
Proposed 4'
Living Fence
Existing Garage
Carraiage House
Proposed Rain
Garden 68 SF
Proposed Gravel Walks
Proposed Tabby Paver
Proposed Spot
Elevation
Proposed Drainage
Arrow
Site Coverage
ATTACHMENT 8
Page 38
Section VII. Item #1.
HOUSE
26'-00" AMSL
RAMP
15' x 35' POOL
RAMP
23
UP
DW
OVEN
ROBINS ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
LNDRY/ENTRY
TILE FLR.
10' 1 1/8" CLG. HT.
M. CLST
WOOD FLR.
10'-1 1/8" CLG. HT.
M. BATH
TILE FLR.
10'-1 1/8" CLG. HT.
MASTER
BEDROOM
WOOD FLR.
10'-1 1 /8" CLG. HT.
PWDR
WOOD FLR.
10'-1 1/8" CLG. HT.
PANTRY
WOOD FLR.
10'-1 1/8" CLG. HT.
HALL
WOOD FLR.
10'-1 1/8" CLG. HT.
KITCHEN
WOOD FLR.
10'-1 1/8" CLG. HT.
D. ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
L. ROOM
WOOD-FLR.
10'-1 1/8" CLG. HT.
BATH #2
TILE FLR.
10' 1 1/8" CLG. HT.
CLOSET
WOOD FLR.
10' 1 1/8" CLG. HT.
SAFE ROOM
WOOD FLR.
10'-1 1/8" CLG. HT.
FRONT PORCH
T&G FLR.
SIDE PORCH
T&G P.T. FLR.
OF 4 SHEET 4
Chk'd By:
Project ID:
Issue / Revision DescriptionNo.
Drawn Date:
Chk'd By:
Project ID:
Sheet No.
M. Brock
po box 358, port royal
south carolina, 29935
ph. 843.540.6407
mbrock@mbrockdesigns.com
J. M. BROCK
RLA
copyright © M. Brock, RLA all rights reserved
LS-104
Landscape Plan E
E
Drawn By: Drawn By:M. Brock
1
25004
Site Development Plans For
Mikulak Residence
95 Green St.
Bluffton, SC
11.18.25 2
SUBMITTAL
12/25
MBDLANDSCAPE PLAN
1" =10'-0"
PROJECT NOTES:
Owner: Glenda Mikulak
Property Address: 95 Green St.
Property Lot Number: 2A
Tax ID Number: R610 039 00A 0347 0000
Property Area: 0.334 Acres
CONTRACTOR NOTE:
·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND
SHALL NOT AFFECT NEIGHBORING PROPERTIES.
Plant Schedule
Proposed Pool
By Others
Live Oak
Proposed Crushed
Granite Drive
(1,242 SF)
WIRE AND WOOD FENCE
LIVING FENCING - 31 LF / 1 Gates
"LIVING FENCE"N.T.S.
2 LS104
Tabby Pavers
Proposed 4'
Living Fence
Proposed 6' Privacy Fence
6' PRIVACY FENCING
N.T.S.
1 LS104
Approx. 92 LF/ 1- Double Gate
Existing Garage
Carraiage House
CONTRACTOR NOTE:
·ALL STORM WATER DRAINAGE TO REMAIN ON SITE AND
SHALL NOT AFFECT NEIGHBORING PROPERTIES.
#65 'Natchez' Crape
Myrtle- Standard
Dw Podocarpus
Tea Olive Graceful Bamboo
Live Oak
Live Oak
Live Oak
Pink Muhly Grass
Upright Holly
Podocarpus
Site Coverage
ATTACHMENT 8
Page 39
Section VII. Item #1.
ATTACHMENT 9
Page 40
Section VII. Item #1.
ATTACHMENT 9
Page 41
Section VII. Item #1.
ATTACHMENT 9
Page 42
Section VII. Item #1.
ATTACHMENT 9
Page 43
Section VII. Item #1.
ATTACHMENT 10
Page 44
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12-032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A1.1
COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 45
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12-032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03..20.13
A1.2
COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 46
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12-032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A2.1
COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 47
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12- 032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A3.1
COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 48
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12- 032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A3.2
COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 49
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12- 032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A4.1
COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 50
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12- 032
NOVEMBER 27 ,2012
01.28.13
03.11.13
03.20.13
A4.2
COPYRIGHT 2012 LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 51
Section VII. Item #1.
A
B D
SHEET
DATE:
REVISION:
DESIGNED BY
DRAWN BY
PROJECT NUMBER
S. LIBERTI
SAL
12-032
NOVEMBER 27 ,2012
01.28.13
03.11.13
E2.1
COPYRIGHT 201LOW TIDE DESIGNS, THE USE OF THE DOCUMENT(S) AND THE DESIGN CONTENT WITHOUT WRITTEN PERMISSION FROM LOW TIDE DESIGNS IS PROHIBITED.
&23<5,*+7/2:7,'('(6,*167+(86(2)7+('2&80(176$1'7+('(6,*1&217(17:,7+287:5,77(13(50,66,21)520/2:7,'('(6,*16,6352+,%,7('APPROVED FOR CONSTRUCTION
ATTACHMENT 10
Page 52
Section VII. Item #1.
M E M O R A N D U M
TO: Historic Preservation Commissioners
FROM: Town of Bluffton Growth Management Staff
RE: Site Feature Permits from April 17, 2026, to May 16, 2026
DATE: June 1, 2026
SUMMARY: Town Staff will be updating the Historic Preservation Commission (HPC) monthly on all site
feature permits that have been applied for, approved, denied, withdrawn, put on hold, or issued. These
permits are reviewed at Staff level.
Address Description of Application Staff Status
45 Bridge St Painting and front door repairs
(HP Grant)
Glen Umberger Approved
216 Bluffton Rd Signage: Hoof & Hound Caroline Luke Approved
8 Church St Porch Extension Caroline Luke Approved
5804 Ginkgo Ln Residential Reroof Caroline Luke Approved
194 Bluffton Rd Commercial window replacement Caroline Luke Approved
101 Calhoun St Renovations to church entrance Glen Umberger Applied
181 Bluffton Rd Unit
C101
Signage: Bluffton Tax Advisor Caroline Luke Applied
2 Water St Carport Renovations Caroline Luke Applied
6 Church St Renovations to exterior (pathway,
windows, etc.)
Caroline Luke Applied
Page 53