Historic Preservation Commission Meeting — Agenda Packet
Town of Bluffton · Beaufort County · Historic Preservation Commission · meeting of May 6, 2026 · Agenda packets
Open the original document More from Town of Bluffton
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Historic Preservation Commission Meeting
Wednesday, May 06, 2026 at 6:00 PM
Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers,
20 Bridge Street, Bluffton, SC
AGENDA
This meeting can be viewed live on BCTV, on Sparklight Channel 9 and 417 or on Spectrum Channel
1304.
I. CALL TO ORDER
II. ROLL CALL
III. NOTICE REGARDING ADJOURNMENT
The Historic Preservation Commission will not hear new items after 9:30 p.m. unless authorized by
a majority vote of the Commission Members present. Items which have not been heard before
9:30 p.m. may be continued to the next regular meeting or a special meeting date as determined
by the Commission Members.
IV. ADOPTION OF MINUTES
1. March 4, 2026 Minutes
V. PUBLIC COMMENT
VI. OLD BUSINESS
VII. NEW BUSINESS
1. Certificate of Appropriateness (204 Bluffton Road): A request by Thomas Michaels, Jr. (SM7
Design, LLC), Applicant, on behalf of 204 Bluffton Road, LLC, Owner, for approval of a
Certificate of Appropriateness to allow the construction of a 3-story 3,978 SF Main Street
Building at 204 Bluffton Road. The property is in the Promenade development in Old Town
Historic District and zoned Neighborhood Core-Historic District (NC-HD). (COFA-12-25-020072)
(Staff-Charlotte Moore)
VIII. DISCUSSION
1. Historic District Monthly Update. (Staff)
IX. ADJOURNMENT
NEXT MEETING DATE: Wednesday, June 3, 2026
Page 1
Town of Bluffton, SC Historic Preservation Commission Meeting Agenda May 06, 2026
“FOIA Compliance – Public notification of this meeting has been published and posted in compliance
with the Freedom of Information Act and the Town of Bluffton policies.”
In accordance with the requirements of Title II of the Americans with Disabilities Act of 1990 ("ADA"), the
Town of Bluffton will not discriminate against qualified individuals with disabilities on the basis of
disability in its services, programs, or activities. The Town of Bluffton Council Chambers are ADA
compatible. Auditory accommodations are available. Any person requiring further accommodation
should contact the Town of Bluffton ADA Coordinator at 843.706.4500 or
adacoordinator@townofbluffton.com as soon as possible but no later than 48 hours before the
scheduled event.
Executive Session – The public body may vote to go into executive session for any item identified for
action on the agenda.
*Please note that each member of the public may speak at one public comment session and a form must
be filled out and given to the Town Clerk. To submit a public comment online, please click here:
https://www.townofbluffton.sc.gov/FormCenter/Town-15/Public-Comment-60
Public comment is limited to 3 minutes per speaker.
Page 2
Historic Preservation Commission Meeting
Theodore D. Washington Municipal Building, Henry “Emmett” McCracken Jr. Council Chambers, 20
Bridge Street, Bluffton, SC
March 04, 2026
I. CALL TO ORDER
Chairman DePauw called the meeting to order at 6pm.
II. ROLL CALL
PRESENT
Chairman Joe DePauw
Vice Chair Carletha Frazier
Commissioner Tim Probst
Commissioner Debbie Wunder
Commissioner Lisa Sulka
ABSENT
Commissioner Jim Hess
Commissioner Michael Sutcliffe
III. ADOPTION OF MINUTES
1. February 4, 2026 Minutes
Commissioner Sulka made a motion to adopt the minutes as written.
Seconded by Vice Chair Frazier.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
IV. PUBLIC COMMENT
V. OLD BUSINESS
1. Certificate of Appropriateness (2 Blue Crab Street, Lot 52): A request by William Court of
Court Atkins Group (Applicant) on behalf of Blue Crab Bluffton, LLC (Owner), for review of a
Certificate of Appropriateness-Historic District to allow the construction of a new 2.5-story
main house (an Additional Building Type) of approximately 3,839 SF and an attached carriage
house of approximately 880 SF at 2 Blue Crab Street. The property is located in the Tabby
Roads Development in Old Town Historic District and zoned Neighborhood General-Historic
District (NG-HD). (COFA-09-25-019925) (Staff - Charlotte Moore)
Staff presented. The applicant was present. There was discussion regarding the porch height
and the associated railing requirements. The commissioners also raised questions about the
removal of trees and the required mitigation measures. The Commission reviewed the use of
shutter dogs, the detailing of the louvered panels, and the roof slope.
Chairman DePauw made a motion to approve the application with the following conditions:
Page 3
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes March 04, 2026
1. Provide a front porch railing that is consistent with the second-story porch railing
style and UDO Sec. 5.15.6.E.5.c.
2. Provide a shutter dog that is an “S” or rat-tail type to comply with UDO Section
5.15.6.M.1.d.
3. Provide two hardwood trees on-site (or five caliper inches) to mitigate the loss of
trees to be removed unless otherwise determined by the UDO Administrator.
4. Change louver panel detail (1/A5.1) to show false wood louvers in the opening
instead of lap siding.
5. Revise details 2/A5.1 and 5/A5.1 to remove the flat ceiling and revise it to follow the
roof slope of the bracketed roof.
And the following were determined to be appropriate:
1. The use of boral for porch columns, corner boards, drip caps, fascia, vents, the top rail
at the second-story rear porch, service yard gate elements, and sills.
2. The use of welded powder-coated aluminum for porch handrails and balustrades
(but not the product as shown in the cut sheet provided with the submission).
3. The use of composite material as an overlay on the garage doors.
4. The use of composite shutters (as shown in the cut sheet provided with the
submission).
Seconded by Commissioner Sulka.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
Chairman DePauw made a motion to amend the approved motion for clarification
purposes.
Seconded by Commissioner Probst.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
Commissioner Sulka made a motion to clarify that the following condition is not required:
1. Provide a front porch railing that is consistent with the second-story porch railing
style and UDO Sec. 5.15.6.E.5.c.
Seconded by Commissioner Probst.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
2. Certificate of Appropriateness (4 Blue Crab Street, Lot 51): A request by William Court of
Court Atkins Group (Applicant) on behalf of Patrick Mason (Owner), for review of a Certificate
of Appropriateness-Historic District to allow the construction of a new 2-story main house (an
Additional Building Type) of approximately 3,800 SF and an attached carriage house of
approximately 886 SF at 4 Blue Crab Street. The property is in Tabby Roads Development in
Page 4
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes March 04, 2026
Old Town Historic District and zoned Neighborhood General-Historic District (NG-HD). (COFA-
09-25- 019927) (Staff - Charlotte Moore)
Staff presented. The applicant was present. There was discussion regarding the porch height
and the associated railing requirements. The commissioners also raised questions about the
removal of trees and the required mitigation measures. The Commission discussed the
inconsistency in the railing on the elevations. There were comments regarding the slope of
the roof on the house and of the garage.
Chairman DePauw made a motion to approve the application with the following conditions:
1. Change the railings on second floor porch to match the styling of the bay over the
front door, limiting the diagonal elements to two bays, then transitioning the pickets
to the sides to complete the space between the columns, and vertical pickets for the
space between the columns that are close together.
2. Provide six hardwood trees on-site (or fifteen caliper inches) to mitigate the loss of
trees to be removed unless otherwise determined by the UDO Administrator. If the
UDO Administrator determines that mitigation trees cannot be provided on the site, a
fee-in-lieu of planting may be required per UDO Section 5.3.8.; and,
3. Revise the beam for the bracketed roof over the garage door to be solid timber.
And the following were determined to be appropriate:
1. The use of boral for porch columns, corner boards, drip caps, fascia, vents, the top rail
at the second-floor rear porch, service yard gate elements, and sills.
2. The use of welded powder-coated aluminum for porch handrails and balustrades
(not the material shown on the cut sheet provided with the submission).
3. The use of composite material as an overlay on the garage doors.
Seconded by Commissioner Sulka.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
3. Certificate of Appropriateness (6 Blue Crab Street, Lot 50): A request by William Court of
Court Atkins Group (Applicant) on behalf of Patrick Mason (Owner), for review of a Certificate
of Appropriateness-Historic District to allow the construction of a new 2.5-story main house
(an Additional Building Type) of approximately 3,846 SF and an attached carriage house of
approximately 884 SF at 6 Blue Crab Street, Lot 50. The property is in Tabby Roads
Development in Old Town Historic District and zoned Neighborhood General-Historic District
(NG-HD). (COFA-09-25- 019628) (Staff - Charlotte Moore)
Staff presented. The applicant was present. There was discussion regarding the porch height
and the associated railing requirements. The commissioners also raised questions about the
removal of trees and the required mitigation measures.
Chairman DePauw made a motion to approve the application with the following conditions:
1. Provide 11 hardwood trees on-site (or 27.5 caliper inches) to mitigate the loss of trees
to be removed unless otherwise determined by the UDO Administrator. If the UDO
Page 5
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes March 04, 2026
Administrator determines that mitigation trees cannot be provided on the site, a fee-
in-lieu of planting may be required per UDO Section 5.3.8.;
2. Revise details 1 and 3 on Sheet A5.3 to remove the flat ceiling and revise the ceiling to
follow the slope of the bracketed roof.
And the following were determined to be appropriate:
1. The use of boral for porch columns, corner boards, drip caps, fascia, vents, the top rail
at the second-story rear porch, service yard gate elements, and sills.
2. The use of welded powder-coated aluminum for porch handrails and balustrades (not
the product shown on the cut sheet submitted).
3. The use of composite material as an overlay on the garage doors.
Seconded by Commissioner Sulka.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
4. Certificate of Appropriateness (8 Blue Crab Street, Lot 49): A request by William Court of
Court Atkins Group (Applicant) on behalf of Patrick Mason (Owner), for review of a Certificate
of Appropriateness-Historic District to allow the construction of a new 2-story main house (an
Additional Building Type) of approximately 3,741 SF and an attached carriage house of
approximately 933 SF at 8 Blue Crab Street, Lot 49. The property is in Tabby Roads
Development in Old Town Historic District and zoned Neighborhood General-Historic District
(NG-HD). (COFA-09-25- 019929) (Staff - Charlotte Moore)
Staff presented. The applicant was present. There was discussion regarding the porch height
and the associated railing requirements. The commissioners also raised questions about the
removal of trees and the required mitigation measures.
Chairman DePauw made a motion to approve the application with the following conditions:
1. Provide a minimum front porch height of 30-inches (UDO Sec. 5.15.6.E.5.c.).
2. Provide a shutter dog that is an “S” or rat-tail type to comply with UDO Section
5.15.6.M.1.d.
3. Provide four hardwood trees on-site (or eleven caliper inches) to mitigate the loss of
trees to be removed unless otherwise determined by the UDO Administrator. If the
UDO Administrator determines that mitigation trees cannot be provided on the site, a
fee-in-lieu of planting may be required (UDO Section 5.3.8.).
And the following were determined to be appropriate:
1. The use of boral for porch columns, corner boards, drip caps, fascia, vents, the top rail
at the second-story rear porch, service yard gate elements, and sills.
2. The use of welded powder-coated aluminum for porch handrails and balustrades (but
not as shown on the cut sheet provided with the submission).
3. The use of composite material as an overlay on the garage doors.
4. The use of composite shutters as shown in the cut sheet provided with the
submission.
Page 6
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes March 04, 2026
Seconded by Commissioner Sulka.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
VI. NEW BUSINESS
1. Certificate of Appropriateness (1 Garfields Way): A request by Ansley Manuel of Manuel
Studios (Applicant) on behalf of Samuel Kopotic (Owner), for review of a Certificate of
Appropriateness-Historic District to allow the construction of a new 2-story main house (an
Additional Building Type) of approximately 2,478 SF and a 2-story attached Carriage House
(garage) of approximately 1,188 SF to be constructed at 1 Garfields Way in the Moss Oaks
Subdivision within Old Town Bluffton Historic District and zoned Neighborhood General-HD
(NG-HD). (COFA-09-25-019941) (Staff - Charlotte Moore)
Staff presented. The applicant was present. The Commission discussed the rear elevation,
noting concern with the long, unbroken roofline. There was concern raised regarding the
request to remove a large oak tree due to insufficient documentation. There was discussion
regarding window alignment and sizing on the right elevation
Commissioner Sulka made a motion to approve the application with the following conditions:
1. Provide Town staff a letter from a certified arborist regarding the health of the
24”/15”Live Oak tree which is proposed to be removed. This letter must be dated
after March 4, 2026 HPC.
2. Add a shed dormer at the center of the rear elevation with appropriately sized
windows. The Historic Preservation Review Committee is to review the dormer
addition.
3. Reposition the second-floor window on the right elevation to align with the first-floor
window.
And the following were determined to be appropriate:
1. The use of welded powder-coated aluminum for handrails on the front and rear
porches and front balustrade.
2. The use of polymer composite shutters (as indicated in the cut sheet submitted as
part of the agenda package).
Seconded by Commissioner Probst.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner
Wunder, Commissioner Sulka
All were in favor and the motion passed.
VII. DISCUSSION
1. Historic District Monthly Update. (Staff)
Staff presented. The Commission did not have any questions about the report submitted.
VIII. ADJOURNMENT
Page 7
Section IV. Item #1.
Town of Bluffton, SC Historic Preservation Commission Meeting Minutes March 04, 2026
Commissioner Sulka made a motion to adjourn.
Seconded by Vice Chair Frazier.
Voting Yea: Chairman DePauw, Vice Chair Frazier, Commissioner Probst, Commissioner Wunder,
Commissioner Sulka
All were in favor and the motion passed. The meeting adjourned at 7:43pm.
Page 8
Section IV. Item #1.
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
HISTORIC PRESERVATION
COMMISSION
STAFF REPORT
Department of Growth Management
MEETING DATE: May 6, 2026
PROJECT: COFA-12-25-020072
204 Bluffton Road (Lot 8) – New Construction
APPLICANT: Thomas Michaels, Jr. (SM7 Design, LLC)
PROPERTY OWNER: 204 Bluffton Road, LLC
PROJECT MANAGER: Charlotte Moore, AICP, Principal Planner
APPLICATION REQUEST: The Applicant, Thomas Michaels, Jr. (SM7 Design, LLC) on behalf
of the owner, 204 Bluffton Road, LLC, requests that the Historic Preservation Commission
(HPC) approve the following application:
A Certificate of Appropriateness-Historic District to allow the construction of
a new 3-story 3,978 SF Main Street Building at 204 Bluffton Road. The
property is in the Promenade development in Old Town Historic District and
zoned Neighborhood Core-Historic District (NC-HD).
INTRODUCTION: The 3-story mixed-use building, with a footprint of approximately 1,326
SF and total square footage of approximately 3,978 SF, is designed as a Mainstreet Building
type (Attachment 7).
The building will be located underneath a hip roof. The first story will be clad with brick. The
second and third stories will be clad with Hardie horizontal lap siding. Trim, including
soffits, will be cementitious material.
The front elevation includes three stories of porches with a length of approximately 75% of
the building width. The ground level porch will be supported by two 1’-2” wide brick
columns that frame the storefront entrance. The second and third story porches will have
1’-0” wide wood columns and powder coated aluminum railings. The third-story porch will
be located underneath a metal shed roof with exposed rafter tails and 6x6 wood brackets.
Porches will also be located on the rear elevation underneath a metal hip roof with
exposed rafter tails and the same columns and railings as the front elevation. The ground
floor porch will be a service area screened by horizontal wood louvers. The left elevation
will include a staircase to separate second-story residential entrances. The landing will be
located underneath a hip roof that will be supported by two wood columns. The area
underneath the landing will be screened with wood louvers.
Page 9
Section VII. Item #1.
May 6, 2026 Page 2
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
Overall, the building is reflective of the vernacular characteristics of Bluffton, as well as the
Calhoun Street Promenade, with architectural volume and styling. The Calhoun Street
Promenade Owners’ Association Architectural Committee has approved the plan
(Attachment 10).
This project was initially presented to the Historic Preservation Review Committee for
conceptual review at the January 26, 2026 meeting and comments were provided to the
Applicant (See Attachment 4). A second conceptual review with HPRC was held on March
23, 2026 as the initial HPRC comments were numerous.
REVIEW CRITERIA & ANALYSIS: In its review of this COFA-HD application, Town Staff and
the Historic Preservation Commission are required to consider the criteria set forth in
Unified Development Ordinance (UDO) Section 3.18.3 (COFA-HD, Application Review
Criteria), applying the standards and guidelines of UDO Sec. 5.15, Old Town Bluffton
Historic District. The intent of the standards and guidelines is, in part, to provide guidance
and ensure consistent development without discouraging creativity or forcing the
replication of historic models.
The applicable criteria of UDO Sec.3.18.3 are provided below followed by a Staff Finding
based upon review of the application submittals to date.
1. Consistency with the principles set forth in the Old Town Master Plan and Town
of Bluffton Comprehensive Plan.
a. Finding. The Old Town Master Plan initiatives also include the adoption of a
form-based code that included architectural standards for structures located
within the Old Town Bluffton Historic District. These standards are included in
Article 5 of the UDO. The amendments will be in conformance with those
standards if the conditions noted in #2 of this Section are met.
2. Conformance with the approved Final Development Plan, Subdivision Plan, and
any other agreements or plans that are applicable.
a. Finding. This lot was previously approved with the September 1, 2010,
development plan for the Calhoun Street Promenade. Amendments since that
time have not affected this lot, and neither will the COFA-HD.
3. The application must be in conformance with applicable provisions provided in
Article 5, Design Standards.
a. Findings. The following findings include items that do not appear to comply or
that require a determination of appropriateness from the HPC.
(1) Columns: UDO Section 5.15.6.H.1.a. requires that columns and porch posts
be spaced no farther apart than they are tall as measured from the
Page 10
Section VII. Item #1.
May 6, 2026 Page 3
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
centerlines of the columns and posts. The front porch columns (±11’-1” tall
and ±17’6” wide), as well as the second and third-story porch posts (±10’-4”
tall and ±17’-6” wide; ±8’-2” and ±17’-6” wide, respectively) do not comply
with this requirement. Likewise, the rear service area and porch posts are
also farther apart than tall (±11’-0”, ±10’-3” and ±8’-2” tall and ±13’-9” wide),
as well as the posts at the staircase landing on the left elevation (±9’-8” tall
and ±11’-0” wide). The HPC must determine if the beforementioned column
and porch posts widths are appropriate.
(2) Railings: UDO Section 5.15.6.H.2.d. requires railings to be made of wood
(termite resistant), or painted or natural wrought iron. Powder coated
aluminum is proposed for front and rear porch railings, balusters and
handrails. The railing at the stairwell landing is identified as both power
coated aluminum and wood “rails and pickets.” A railing detail has not been
provided nor has a cut sheet to confirm the dimensions required by UDO
Sec. 5.16.6.H.3.d. will be met. A determination must be made on the
appropriateness of the use of powder coated aluminum as a substitute
material.
(3) Windows:
a. UDO Section 5.15.5.F.4.e. states that “[v]ertical rhythms should be
established in the façade through alignment of windows…” UDO Sec.
5.15.6.I.1.b. also provides that the window openings should be oriented
vertically. Both the right and left elevations include four different window
types that mostly lack vertical alignment and appear to have random
placement from the exterior, unlike the windows in the adjacent
buildings at 202 and 206 Bluffton Road. However, as these elevations
have limited public view, the HPC may consider the appropriateness of
window placement in these elevations.
b. The window material is not identified in the plan set but is shown as
“Glastra” material on the application project analysis sheet, which
references a brochure (Attachment 9). Glastra, according to the
brochure, is “a proprietary hybrid of fiberglass and UV stable polymer.”
While fiberglass is a permitted window material, Glastra is a hybrid and
will require a determination of appropriateness by the HPC.
c. All windows must be labeled by type.
(4) Doors:
a. The door material is not identified in the plan set but is shown as
“Glastra” material on the application project analysis sheet, which
references a brochure (Attachment 9). Glastra, according to the
brochure, is “a proprietary hybrid of fiberglass and UV stable polymer.”
Page 11
Section VII. Item #1.
May 6, 2026 Page 4
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
While fiberglass is a permitted door material, Glastra is a hybrid and will
require a determination of appropriateness by the HPC.
b. The door at the service yard has a single-lite, which is inconsistent with
four-lite doors used elsewhere on the building, including the adjacent
door. This door should be changed to four-lites.
c. All doors must be labeled by type.
(5) Roof Material: A metal roof (“pre-weathered galvalume”) is proposed for the
porches and staircase landing; the configuration has not been identified.
UDO Sec. 5.15.6.J.3.a. requires the configuration to be standing seam or 5-V
crimp with 24-inch maximum spacing with panel ends exposed at the
overhang.
(6) Porch Ceilings: The porch ceiling for the front and rear porches will be a v-
groove configuration, but material has not been identified. A side porch
detail has not been provided to identify either the material or configuration. A
v-groove configuration should be provided for all porches, as well as a
consistent material such as pressure-treated wood or cementitious board,
(7) Brick Veneer: The Color Board (Attachment 8) shows that “Old Georgetown”
brick is proposed. Additional information is needed to determine the
manufacturer of the brick to verify the color. “Old Georgetown”
manufactured by General Shale is a red /orange brick that atypical of the
area. “Georgetowne” brick is similar to Savannah Grey, a brown, tumbled
brick.
(8) Electric Meters: Electric meters are proposed to be placed on the rear wall
at the service area. Based on recent experience with meters in Old Town, the
meter location may be required to be moved by the utility company. If an
alternate location is required, meters must be screened.
(9) Right-of-way (ROW) Encroachment: The walkway connection to the public
sidewalk and landscaping in the ROW will require a ROW encroachment
permit from the State of South Carolina Department of Transportation
(SCDOT). Additionally, any State signage to be relocated will require written
proof of approval from SCDOT.
4. Demonstration of a compatible visual relationship between new construction
or alterations and existing buildings, streetscapes and open spaces. A
compatible visual relationship must be generally of a similar structural mass,
scale, height, proportion, directional expression of the principal elevation and
rhythm of spacing, as applicable;
Page 12
Section VII. Item #1.
May 6, 2026 Page 5
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
Finding . The mass and scale of the structure is appropriate for its location and the
architectural volume and detailing sensitive to the neighboring properties.
5. Compliance with applicable requirements in the Applications Manual.
Finding. The Certificate of Appropriateness Application has been reviewed by Town
Staff and has been determined to be complete.
STAFF RECOMMENDATION: It is the charge of the HPC to assess and interpret the
standards and guidelines set forth in the UDO as they pertain to applications using the
review criteria established in the UDO and to take appropriate action as granted by the
powers and duties set forth in Section 2.2.6.E.2. Town Staff finds that the requirements of
Section 3.18.3 of the Unified Development Ordinance have been met and recommends
that the Historic Preservation Commission approve the application subject to the following
conditions and determinations:
Conditions:
1. Revise the plan to show all windows by type.
2. Revise the plan to show a service area door that matches the adjacent four-lite
door.
Revise the plan to show all doors by type.
3. Revise the plan to show a standing seam or 5-v roof configuration.
4. Revise the plan to show porch ceilings with pressure-treated wood or cementitious
board.
5. Revise the plan to show railing details.
6. Identify the brick manufacturer and specific brick to be used for the front porch
columns and first-story wall cladding.
7. If electric meters must be relocated, they shall be screened with landscaping or
other screening method as determined by the HPC.
8. Provide a ROW encroachment permit for any work within the Bluffton Road right-of-
way.
Determinations: The determinations below must be considered for their appropriateness.
If not acceptable, the HPC must provide an alternative or deny the request.
1. The proposed widths of all columns and posts that are farther apart than they are
tall.
2. The use of powder-coated aluminum for the porch railings, balusters and handrails.
3. The use of Glastra material for windows and doors.
4. The placement of windows in the right and left elevations.
HISTORIC PRESERVATION COMMISSION ACTIONS: As granted by the powers and duties
set forth in Section 2.2.6.E.2, the Historic Preservation Commission has the authority to
take the following actions with respect to this application:
1. Approve the application as submitted by the Applicant;
Page 13
Section VII. Item #1.
May 6, 2026 Page 6
204 Bluffton Road – Certificate of Appropriateness Historic Preservation Commission
2. Approve the application with conditions; or
3. Deny the application as submitted by the Applicant.
ATTACHMENTS:
1. Application
2. Location and Zoning Map
3. Lot Survey
4. Narrative & HPRC Comments Response
5. Photos
6. Conceptual Rendering with Adjacent Buildings
7. Architectural and Landscape Plans
8. Color Board
9. Window and Door Brochure
10. Promenade Approval Letter
Page 14
Section VII. Item #1.
Elizabeth A Drake
dotloop verified
03/04/26 9:44 AM EST
FLE4-HVAE-DUDP-RLQK
03/04/2026
dotloop signature verification: dtlp.us/rf62-zHCb-GoIy
Page 15
Section VII. Item #1.
dotloop signature verification: dtlp.us/rf62-zHCb-GoIy
Page 16
Section VII. Item #1.
dotloop signature verification: dtlp.us/rf62-zHCb-GoIy
Page 17
Section VII. Item #1.
dotloop signature verification: dtlp.us/rf62-zHCb-GoIy
Page 18
Section VII. Item #1.
dotloop signature verification: dtlp.us/rf62-zHCb-GoIy
Page 19
Section VII. Item #1.
LOCATION MAP
204 Bluffton Road
Neighborhood Core-HD District
Page 20
Section VII. Item #1.
EXHIBIT A
Page 21
Section VII. Item #1.
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
April 7, 2026
Town of Bluffton
20 Bridge Street
Bluffton, SC 29910
RE: 204 Bluffton Road
HD Review Members:
We are requesting conceptual approval of a new building located at 204 Bluffton Road.
Along with this project narrative, we have included the following documents for your
review:
• Historic District Application / Project Analysis
• Project Narrative
• Comments and Responses from Conceptual Meeting
• Existing site survey (Exhibit A)
• Existing photos with location key (Exhibit B)
• Architectural Design Drawings (Exhibit C)
• Proposed Color Palette (Exhibit D)
• Window Brochure for Kolbe Gastra Windows (Exhibit E)
• Conceptual Streetscape Rendering (Exhibit F)
We are very excited to add this project to the Prom enade and the current fabric of
downtown. I look forward to discussing this project further at the next available Historic
District meeting.
Thank you,
Thomas Michaels Jr. - RA
Page 22
Section VII. Item #1.
Page 2 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Project Narrative
Project Narrative U.D.O Information:
The proposed building type used for the development of the design Is the Main Street
Building which is permitted under the Neighborhood Core Historic District Zoning. The
following are the requirements for the main street building lot standards as defined in
section 5.15.5.A General Standards.
Building
Type
Front Build-
to Zone Lot Width Frontage
Requirement
Setback
(from rear
property
line)
Side
Setback
(from side
property
line)
Height (in
stories)
Main Street
Building 10-20’ 50-100’ 70%-90% 25’ 5’ 2-3
Proposed
Building N/A* N/A* N/A* N/A* N/A* 3
*Note: The building lot is a designated building pad and not a traditional lot, so some requirements
are not applicable.
The Main Street Building characteristics are outlin ed in the U.D.O in Section 5.15.8.A.
Below are the requirements and information on how the proposed building complies with
them.
• Size Range: NC-HD: 2,000 – 8,000 sq. ft.
o The proposed building has a conditioned area of 3,978 sq. ft. With exterior
porches and stairs, the total building area is approximately 4,560 sq. ft.
• Maximum Footprint (not including porches): NC-HD: 3,500 sq. ft.
o The proposed building footprint is 1,326 sq. ft.
• Height: NC-HD: 2-3 Stories
o The proposed building is 3 stories.
• Characteristics: A shopfront building. Retail/offic e space on ground floor.
Office/living space on upper levels. Must have an arcade, colonnade, marquee
or awning at the front façade (arcades / colonnades are preferred)
o The first floor is developed as a real estate offic e with shopfront windows.
The second and third floors have living areas. A c olonnade is provided at
the front elevation. Due to the site limitation with the angled street right-of-
way, the clear distance of the colonnade is 5’-4” feet with an overall of 6’-
6” feet finish to finish.
Page 23
Section VII. Item #1.
Page 3 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Project Narrative Additional Information:
Site:
The project is located at 204 Bluffton Road (Lot 8) in the Bluffton Promenade. It is one of
the last remaining building pads to be developed. The building pad measures 26 feet
wide by 51 feet deep and totals 1,326 square feet. An existing survey of the property has
been provided and labeled Exhibit A. The Town of Bluffton zoning is Neighborhood Core
– HD.
The site is situated between two existing structure s located at 202 Bluffton Road to the
North and 206 Bluffton Road to the South. The photos and location key provides existing
photos looking at the property and looking out from the property. Images 1-3 are views
from across Bluffton Road. Image 6 is a view of the lot from the rear parking court. Images
4, 5, 7 and 8 are taken from the center of the building pad.
Structure:
The project consists of a new three-story building of approximately 3,978 square feet
conditioned. The first floor is planned to be a new real estate office. It will have a main
entry located off Bluffton Road and a rear entry with access from the parking court. The
second and third floors will be residential units. These units will be accessed from an
exterior stair from the first floor as well as an interior elevator.
The front elevation addresses the street with a fir st-floor storefront protected by the
weather with a three-story covered porch. Both res idential units also have access to
covered porches on the second and third levels of t he structure. The building has two
primary finishes. The first floor will be a brick veneer while floors two and three will be a
horizontal siding. The main roof will be an architectural shingle and metal accents will be
located on the front porch and rear porch. Additio n clarification can be found on the
architectural drawings.
Page 24
Section VII. Item #1.
Page 4 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Comments and Responses: March 23 meeting
The following are modifications to the plans based upon the meeting on March 23 rd .:
• Soffits, porch ceilings and exposed roofing areas h ave been identified as a V-
Grove finish compared to the previous smooth finish.
• All windows, besides transoms, have been changed to operable windows. These
are either designated as double hung or casement.
• Caps and bases have been added to the columns at th e first level to match the
second and third levels.
• The horizontal lattice has been removed under the small stair landing.
• A new elevation drawing (1/A204) has been added to show the building behind
the horizontal service yard screening.
• The service yard and rear porch have been enlarged to accommodate three
condenser units, trash storage and electrical services
Comments and Responses: January 26 meeting
Growth Management Review Comments
Comment 1 Site: Show the location of staircases and service yards for adjacent buildings
on the site plan to confirm proximity from the proposed staircase and service yard. Show
connection to public sidewalk. As the colonnade, se rvice yard and staircase extend
beyond the property line, an updated letter of appr oval addressing these items will be
required from the Promenade POA. SCDOT approval req uired to relocate sign (if
relocation needed).
Response: The adjacent stairwells and service have been shown on the site plans
as shaded areas. The service yard on Lot 9 as well as an undocumented drainage
inlet required the building to be flipped so that the second-floor access in from the
Lot 7 side. All new proposed connections have been illustrated on the site plan.
We have submitted to the Promenade POA with the new modifications and will
present and approvals or comments when they are received prior to the meeting.
We are working with SCDOT for the sign relocation a nd the required
encroachment permits.
Comment 2 Brick: A light-colored brick is proposed for the columns, which is not a brick
color that is common to this area. For consistency with Old Town, brick must be a
Savannah Grey color (brownish-grey) with a tumbled texture (UDO Sec. 5.15.6.G.3.h.).
Response: The brick that has been selected is Old Georgetown. It is similar to
Savannah Grey. We have included a color image on the color board and will
bring in a full-size sample to present at the HD meeting.
Page 25
Section VII. Item #1.
Page 5 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Comment 3 Columns: The colonnade columns are bulky given their width (2’-6”) and
reduce full visibility of the storefront. Show the location of the rear porch columns on the
site plan (Sheet A001).
Response: The front columns have been reduced to a finished width of 2’-0”. All
column locations have been shown on the site plan (Sheet A001) and the
Landscape Plan (Sheet A002)
Comment 4 Service Yard Fence: The fence is shown to be 6’-6”; fence height must be
no taller than 6 feet (UDO Sec. 5.15.5.F.9.c.).
Response: Due to the repositioning of the building on the site (please refer to
Comment 1 above) the service area was relocated to the rear of the building
under the porch. This area will be for service and access to the fire riser room.
The horizontal boards for screening have been extended to full height to match
the side porch and stairs.
Comment 5 Signage: Signage is not reviewed with the COFA application. Per Section
3.19 of the UDO, a Site Feature-HD is required for any signs proposed on the site.
Response: We have removed any building signage from the submittal. When a
signage design is selected, we shall submit the app ropriate application and
documents
Comment 6: Final Plan Submission: The Final Plan, t o be reviewed by the Historic
Preservation Commission (HPC), must include all req uired materials, as indicated on the
COFA application. A complete application includes p roviding a written response to
these HPRC comments, identification of all materials, configurations and dimensions that
are consistent with UDO requirements. If variations are sought, they must be identified in
the narrative to submitted with the application. Details must include corner boards, wall
section through eave, corner boards, balustrade/rai lings, window and door schedules,
gutters, and other applicable items. Please review UDO Section 5.15 (Old Town Bluffton
Historic District) for specific requirements. An incomplete submission will not be scheduled
for HPC review until such time as all required items are provided.
Response: We feel we have prepared a submittal that addresses the UDO and the
comments from the January meeting.
HPRC Review Comments
Comment 1 Height: The building appears much taller than neighboring buildings;
consider lowering each story by one foot. [Note: Th e height to the top of the cupola is
48’-8 3/8”. The height of the adjacent properties to the roof ridge are 43’-0” (202 Bluffton)
and 41’-9” (206 Bluffton).]
Page 26
Section VII. Item #1.
Page 6 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Response: The overall height of the structure to th e peak of the roof has been
reduce to +/- 42’-11”. This has been accomplished by the following methods:
• Reducing the plate height of the first floor by one foot to a plate
height of 11’-0”.
• Reducing the plate height of the third floor by 6” to a plate height of
9’-6”
• Altering the main roof pitch from an 8:12 pitch to a 7:12 pitch.
• Deletion of the cupola.
These modifications have brought the height more in line with the neighboring
buildings.
Comment 2: Front Porch Entry / Columns: The front p orch entry should be restudied. The
columns are too tall, lack detailing and should be no taller than one-story. For a masonry
application, they are also too skinny. Traditional brick masonry should visually ground a
structure and provide scale. The relationship between the windows and columns should
also be restudied as the windows continue past the porch.
Response: The front entry porch has been redesigned to address the comments.
The brick columns have been reduced to a single sto ry, and the second-floor
column has been modified to a more traditional wood appearance.
Comment 3 Side Porch / Stairs: Restudy the side por ch structure. The skinny deck posts
are too slender and would benefit from a thoughtful cross bracing or screening detail.
Related to the porch, the underside of the stairs should appear finished from the street if
they are left exposed.
Response: The side entry porch and stairs have been redesigned. Larger columns
and horizontal screening have replaced the previous design. The side entry is now
similar to other structures in the Promenade.
Comment 4 Rear Porch: Restudy the size of the rear porch columns which are
disproportionate to the height of the porch. Consid er changing the column size/design
as the floors process upward.
Response: The rear porch columns have been restudied and adjusted to be similar
with the front and side porches. The horizontal boards for the service area add a
base to the upper porch levels.
Comment 5 Porch Roofs: Consider creating more inter est in the porch roofs, such as
adding exposed rafters.
Response: The soffit design for the front porch, re ar porch and side entry have
been redesigned to include exposed rafter tails.
Page 27
Section VII. Item #1.
Page 7 of 7
SM7 DESIGN LLC ● 19 Promenade St. ● Suite 201 ●
PO Box 2287 ● Bluffton ● South Carolina ● 29910
Comment 6 Cupola: The cupola on the top of the roof should serve a purpose, create a
unique detail, or be removed. A cupola that lacks d etailing and makes more lap siding
and corner boards is not appropriate. The structure is already taller than its neighbors
based on its taller floor heights, so a strong argu ment as to why the cupola should be a
part of the design is necessary.
Response: The cupola has been removed from the design to assist in reducing the
overall height of the structure. (Please reference Comment 1 above)
Comment 7 Brackets: Front porch brackets should sup port a beam which supports the
rafters. The beam appears to be missing. This comme nt also applies to the back door
bracketed roof.
Response: Beam have been added in the appropriate locations for both the front
poch and the rear door awning.
Comment 8 Windows: Restudy the window details in the brick walls. A brick header and
sill detail is more appropriate to the Bluffton ver nacular than wood casing. Window lites
should have vertical proportions (UDO Sec. 5.15.6.I .). Consider making the square
windows on the right elevation taller, even if they already meet the UDO requirement.
Response: The windows in the brick wall have been m odified to show the
appropriate brick header and sill. All of the wind ows have been restudied, and
additional windows have been added to both side ele vations to create a better
interior environment
Comment 9 Doors: The Riser Room door appears to hav e three horizontal divides which
do not match the architecture of the adjacent door.
Response: The rear riser room door has been changed to a flat door. It shall be
screened from public view from the horizontal lattice.
Comment 10 Water Table: Consider a brick water table on the brick between floors.
Response: We have restudied the elevations and have added a brick water table
between the first and second floor, replacing the w ood skirting on the previous
submission. We have also added a base to the first floor to provide additional
interest and a bottom termination.
Page 28
Section VII. Item #1.
IMAGE 1. VIEW OF LOT LOOKING SOUTHWEST
IMAGE 2. VIEW OF LOT LOOKING WEST
IMAGE 3. VIEW OF LOT LOOKING NORTHWEST
IMAGE 4. VIEW FROM LOT LOOKING NORTH
IMAGE 5. VIEW FROM LOT LOOKING EAST
IMAGE 6. VIEW OF LOT LOOKING EAST
IMAGE 7. VIEW FROM LOT LOOKING WEST
IMAGE 8. VIEW FROM LOT LOOKING SOUTH
EXHIBIT B
1
2
3
4
5
7
8
6
Page 29
Section VII. Item #1.
conceptual rendering
204 Bluffton Road
Page 30
Section VII. Item #1.
NEW COMMERCIAL
204 BLUFFTON RD, BLUFFTON, SC 29910
SM7 DESIGN LLC
1011 BAY STREET, SUITE 314
BEAUFORT, SC 29902
PH: 843.900.1841
EMAIL: INFO@SM7DESIGN.COM
Page 31
Section VII. Item #1.
G001
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
TITLE SHEET
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
SHEET INDEX
Scale: NTS1
PROJECT DATA
Scale: NTS2
SYMBOLS AND ABBREVIATIONS
Scale: NTS4 GENERAL NOTES
Scale: NTS3
NEW CONSTRUCTION RENOVATION UPFIT ALTERATION
NAME OF PROJECT:
ADDRESS:
PROPOSED USE:
OWNER / AUTHORIZED AGENT:
OWNED BY: CITY/COUNTY PRIVATE STATE
CODE ENFORCMENT
JURISDICTION: CITY: BLUFFTON COUNTY: BEAUFORT STATE: SC
SHEET INDEX
DRAWING
NUMBER DRAWING NAME ISSUE DATE REVISION
DATE NOTES
G000 COVER SHEET
G001 TITLE SHEET
A001 ARCHITECTURAL SITE PLAN
A002 LANDSCAPE PLAN
A101 FIRST / SECOND FLOOR PLAN
A102 THIRD FLOOR / ROOF PLAN
A201 ELEVATIONS
A202 ELEVATIONS
A203 ELEVATIONS
A204 ELEVATIONS
A401 WALL SECTIONS
A402 WALL SECTIONS
A501 DETAILS
A502 DETAILS
A503 DETAILS
A504 DETAILS
A505 DETAILS
A602 SCHEDULES
PROJECT INFORMATION:
PROJECT SUMMARY:
THE PROJECT IS A NEW SINGLE FAMILY RESIDENCE WITH THE FOLLOWING AREA:
APPLICABLE BUILDING CODES:
- INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION, WITH SOUTH CAROLINA AMENDMENTS
NEW PROJECT
204 BLUFFTON RD, BLUFFTON, SC 29910
1. ALL WORK TO BE PERFORMED AND ALL MATERIALS AND FINISHES TO BE INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF
ALL APPLICABLE BUILDING CODES, STANDARDS AND ORDINANCES ADOPTED BY THE AUTHORITY(IES) HAVING JURISDICTION (AHJ) OF
THE WORK. THIS SHALL INCLUDE REQUIREMENTS BY ANY AND ALL UTILITY COMPANIES, HEALTH DEPARTMENTS OR OTHER AGENCIES
HAVING JURISDICTION. PRIME GENERAL CONTRACTOR TO PROVIDE THE OWNER WITH CERTIFICATE OF OCCUPANCY PRIOR TO
RECEIPT OF FINAL PAYMENT.
2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE AHJ, OBTAIN
ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY THE AHJ AS REQUIRED.
3. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT
ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. CONTRACTOR SHALL REVIEW THESE PLANS
THOROUGHLY, MAKE A DETAILED SITE VISIT, AND SHALL IMMEDIATELY BRING ANY INCONSISTENCY, SITE LAYOUT PROBLEM, OR ANY
OTHER REQUEST FOR CLARIFICATION TO THE ARCHITECT FOR RESOLUTION PRIOR TO THE DELIVERY OF ANY BID. FAILURE TO DO SO
SHALL CAUSE THE CONTRACTOR TO BE INELIGIBLE FOR EXTRAS RELATING TO SUCH MATTERS.
4. THE PRIME GENERAL CONTRACTOR IS RESPONSIBLE FOR HAVING ALL PROJECT PRIME CONTRACTORS AND SUBCONTRACTORS
COORDINATE THEIR WORK WITH THE WORK OF OTHER TRADES AND IS RESPONSIBLE FOR THE COORDINATION OF ALL TRADES AND
WORK INCLUDING WORK NOT IN THE CONTRACT AS WELL AS WORK PERFORMED BY SEPARATE SUBCONTRACTORS RETAINED BY THE
OWNER UNDER SEPARATE AGREEMENT. ALL SUCH WORK NOT IN CONTRACT SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO
THE COMMENCEMENT OF CONSTRUCTION.
4. ALL PRIME CONTRACTORS ARE TO FURNISH THE ARCHITECT WITH INSURANCE CERTIFICATES AS REQUIRED PRIOR TO
COMMENCEMENT OF THE WORK AND TO FURNISH THE ARCHITECT WILL ALL WAIVERS OF LIENS SPECIFIED BY THE ARCHITECT PRIOR
TO THE RECEIPT OF ANY AND ALL PAYMENTS.
5. PRIME GENERAL CONTRACTOR IS TO COORDINATE THEIR ACTIVITIES DURING CONSTRUCTION WITH THE ARCHITECT AND TO
PROVIDE THE ARCHITECT WITH A PROJECT SCHEDULE FOR APPROVAL PRIOR TO COMMENCEMENT OF ANY WORK. THIS PROJECT
SCHEDULE SHALL INCLUDE THE SCHEDULES OF ALL OTHER PRIME CONTRACTORS.
6. ALL PRIME CONTRACTORS ARE TO KEEP A FULL SET OF COMPLETE AND UP TO DATE PLANS AND SPECIFICATIONS AVAILABLE AT
THE PROJECT SITE AT ALL TIMES.
7. ALL PRIME CONTRACTORS ARE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND
PROGRAMS NECESSARY FOR SUCCESSFUL COMPLETION OF THE WORK AND AS REQUIRED BY LAW.
8. PRIME GENERAL CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF THE EXISTING STRUCTURE (IF ANY) DURING THE ENTIRE
DEMOLITION AND/OR CONSTRUCTION PROCESS. PRIME GENERAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ADEQUATE
TEMPORARY SHORING WHERE AND WHEN NECESSARY. PRIME GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE
STRUCTURAL INTEGRITY OF EXISTING FRAMING BEFORE THE REMOVAL OF ANY PARTITION OR STRUCTURAL ELEMENT. THE
CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE
WORK.
9. ALL MATERIALS SUPPLIED BY THE PRIME CONTRACTORS TO BE NEW AND OF BEST QUALITY AVAILABLE. ALL LABOR AND MATERIAL
TO BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL PAYMENT. THE PRIME CONTRACTORS ARE TO INSTALL
ALL MATERIAL AND LABOR, UNLESS SPECIFICALLY NOTED, FOR THE COMPLETE INSTALLATION OF ALL WORK AS SPECIFIED HEREIN.
DELIVER PRODUCTS SCHEDULED FOR USE IN THE WORK WITHIN THE MANUFACTURERS ORIGINAL CONTAINER WITH LABELS INTACT.
MAINTAIN FINISHED SURFACES CLEAR, UNMARRED AND SUITABLY PROTECTED UNTIL ACCEPTED BY THE OWNER. IN THE EVENT OF
DAMAGED, PROMPTLY REPAIR OR REPLACE AT NO ADDITIONAL COST TO THE OWNER OR EXTENSION IN THE CONTRACT TIME OF
COMPLETION.
10. PROJECT CONTRACT CLOSE-OUT SUBMITTALS TO INCLUDE, BUT NOT LIMITED TO: PROJECT RECORD DOCUMENTS, OPERATION
AND MAINTENANCE DATA, WARRANTIES AND BONDS, KEYS AND KEYING SCHEDULE, SPARE PARTS AND MATERIAL STOCK,
CERTIFICATES OF INSPECTION/OCCUPANCY/INSURANCE, EVIDENCE OF PAYMENT AND RELEASE OF LIENS, AND A LIST OF
SUBCONTRACTORS, PRINCIPAL VENDORS AND SERVICE ORGANIZATIONS, INCLUDING EMERGENCY TELEPHONE NUMBERS. INSTRUCT
THE OWNER ON PROPER OPERATION AND MAINTENANCE OF SYSTEMS, EQUIPMENT AND SIMILAR ITEMS PRIOR TO RELEASE OF FINAL
PAYMENTS TO THE PRIME CONTRACTORS AND/OR RELATED SUBCONTRACTOR.
11. ALL PRIME CONTRACTORS ARE RESPONSIBLE FOR THE REMOVAL OF THEIR CONSTRUCTION DEBRIS AS PER ALL GOVERNING
CODES AND ORDINANCES. FINAL CLEAN UP OF ALL WORK AND MATERIAL SHALL BE TO THE OWNER'S SATISFACTION PRIOR TO
COMPLETION. THROUGHOUT THE DEMOLITION AND/OR CONSTRUCTION PERIOD, THE PRIME CONTRACTORS TO MAINTAIN THE
BUILDING AND SITE IN A CLEAN MANNER AND STORE ITEMS IN AN ORDERLY ARRANGEMENT ALLOWING MAXIMUM ACCESS, NOT
IMPEDING THE CONSTRUCTION PROCESS OF ANY SUBCONTRACTOR AND PROVIDING THE REQUIRED PROTECTION OF MATERIALS.
THE PRIME CONTRACTORS SHALL NOT ALLOW THE ACCUMULATION OF SCRAP, DEBRIS AND WASTE MATERIAL. AT THE END OF THE
PROJECT, THE PRIME CONTRACTORS ARE TO REMOVE DUST, DEBRIS, OIL STAINS, FINGERPRINTS AND LABELS FROM EXPOSED
FINISHED SURFACES, INCLUDING GLAZING.
12. SUBSTITUTIONS EQUAL TO THE ITEMS SPECIFIED WILL BE CONSIDERED ONLY WHEN REQUIRED BY CODE OR INSURANCE, WHEN
PROVEN UNAVAILABLE OR UNSAFE, OR WHEN A MANUFACTURER REFUSES TO CERTIFY PERFORMANCE, WHEN IT WOULD BE
SUBSTANTIALLY TO THE OWNER'S BEST INTEREST IN TERMS OF COST, TIME, OR OTHER CONSIDERATION. ALL SUBSTITUTIONS SHALL
BE APPROVED IN WRITING BY THE ARCHITECT IN ADVANCE OF THEIR PURCHASE OR INSTALLATION BY THE SPECIFIED PRIME
CONTRACTOR.
13. FURNISH SHOP DRAWINGS (IF APPLICABLE), SAMPLES AND PROJECT DATA WHEN NOTED FOR REVIEW AND APPROVAL BY THE
ARCHITECT AFTER CHECKING AND CERTIFYING COMPLIANCE WITH THE CONTRACT DOCUMENTS. SUCH INFORMATION SHALL BE
SUBMITTED WITH A SIGNATURE AND DATE MARKED "CONTRACTOR APPROVED".
14. PROVIDE TEMPORARY FACILITIES AND CONTROLS REQUIRED FOR THE WORK, INCLUDING BUT NOT LIMITED TO: TEMPORARY
UTILITIES SUCH AS HEAT OR AIR CONDITIONING, WATER, ELECTRICITY, TELEPHONE, FIELD OFFICE, SANITARY FACILITIES,
ENCLOSURES SUCH AS TARPAULINS, BARRICADES AND CANOPIES. GENERAL CONTRACTOR TO PROVIDE NECESSARY SAFETY
PROTECTIONS FOR GENERA PUBLIC AT ALL TIMES.
15. ALL PRIME CONTRACTORS ARE TO UNCOVER WORK TO PROVIDE FOR AN INSPECTION OF INSTALLATION OF ILL-TIMED WORK.
REMOVE AND REPLACE ALL WORK NOT CONFORMING TO REQUIREMENTS OF THE CONTRACT DOCUMENTS AT THE PRIME
CONTRACTORS OWN COST.
16. ALL PRIME CONTRACTORS ARE TO REVIEW DOCUMENTS WITH THE ARCHITECT AND THE OWNER AND SUBMIT IN WRITING, A
DESCRIPTION OF RESPONSIBILITIES IN REGARD TO ALL OWNER SUPPLIED ITEMS , INCLUDING MATERIALS AND DETAILS PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION.
17. OWNER TO VERIFY THE LOCATION OF ANY AND ALL UNDERGROUND UTILITIES AND SEPTIC INSTALLATIONS PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION.
18. ALL DIMENSIONS TO FACE OF STUD/STRUCTURE FOR INTERIOR AND EXTERIOR WALLS PARTITIONS UNLESS OTHERWISE NOTED.
VERIFY ACTUAL CONDITIONS BEFORE BEGINNING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR INSUREING THAT THE
FRAMING DIMENSIONS WILL PRODUCE THE FINISH FLOOR PLANS AS SHOWN IN THE DRAWINGS. CONTRACTOR TO HAVE ALL CHANGES
APPROVED IN WRITTING BY THE ARCHITECT. IN CASE OF DISCREPANCIES, NOTIFY ARCHITECT PRIOR TO INSTALLATION.
19. THE CONTRACTOR IS NOT TO SCALE DRAWINGS OR DETAILS. ONLY WRITTEN DIMENSIONS ARE TO BE USED.
20. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK
SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS.
21. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF THE AHJ.
22. EACH CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER
CONTRACTORS (PLUMBING, ELECTRICAL, MECHANICAL, FIRE PROTECTION).
23. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR
AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.
24. EACH CONTRACTOR SHALL DO CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE
DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB IN EACH PRIME CONTRACT.
25. ALL MATERIALS, ASSEMBLIES, FORMS AND METHODS OF CONSTRUCTION AND SERVICE EQUIPMENT SHALL COMPLY WITH THE
REQUIREMENTS OF THE AHJ AND ALL APPLICABLE CODES.
26. EACH CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE OTHER CONTRACTORS AND SUPPLIERS.
27. DUCTS, PIPES AND CONDUITS PASSING THROUGH RATED CONSTRUCTION SHALL HAVE SPACES NOT EXCEEDING 1/2 INCH PACKED
WITH MINERAL WOOL AND CLOSED OFF WITH CLOSE FITTING METAL ESCUTCHEONS. AGGREGATE AREA OF SUCH OPENINGS SHALL
NOT EXCEED 25 SQUARE INCHES IN ANY 100 SQ. FT. OF WALL OR FLOOR AREA UNLESS PROTECTED BY RATED SELF-CLOSING
DEVICES.
28. CONCEALED SPACES WITHIN PARTITIONS, WALLS, FLOORS, ROOFS, STAIRS, FURRING, PIPE SPACES, COLUMN ENCLOSURES, ECT.,
SHALL BE FIRESTOPPED (EXCEPT WHERE CONCEALED SPACE IS SPRINKLERED) NON-COMBUSTIBLE MATERIAL THAT CAN BE SHAPED,
FITTED AND PERMANENTLY SECURED IN POSITION. FIRE SEAL SHALL MATCH RATING OF WALL.
29. CONDUITS IN FIRE-RELATED PARTITIONS SHALL NOT EXCEED 3/4 INCH DIAMETER. OUTLETS IN SUCH PARTITIONS SHALL BE
BACKED UP WITH APPROVED MATERIALS MEETING U.L. REQUIREMENTS.
30. PENETRATION OF OPENINGS IN WALLS, PARTITIONS OR FLOORS, FOR PIPE SLEEVES, FIRE EXTINGUISHERS, TOILET ACCESSORIES,
ELECTRIC DEVICES, ECT., SHALL BE PLACED, SEALED, LINED OR OTHERWISE ISOLATED TO MAINTAIN THE REQUIRED S.T.C. RATING.
PROJECT SCOPE NOTES:
GENERAL NOTES:
THIS SET OF DRAWINGS INDICATES THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE STRUCTURAL SYSTEM, THE ELECTRICAL OUTLETS AND FIXTURE LOCATIONS, AND AN OUTLINE OF
MAJOR ARCHITECTURAL ELEMENTS OF CONSTRUCTION. AS A "SCOPE" DOCUMENT, THESE DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE PROJECT. PRICING
WILL BE BASED ON THESE DOCUMENTS WITH THE UNDERSTANDING THAT THE CONTRACTOR, SUBCONTRACTOR AND/OR MATERIAL
SUPPLIERS ARE TO FURNISH ALL ITEMS FOR PROPER COMPLETION OF THE WORK WITHOUT ADJUSTMENT TO THE CONTRACT OR
SUBCONTRACT PRICE. IT IS INTENDED THAT THE WORK BE OF SOUND, QUALITY CONSTRUCTION IN FULL COMPLIANCE WITH ALL
GOVERNING CODES AND ORDINANCES. THE CONTRACTOR, SUBCONTRACTOR AND MATERIAL SUPPLIERS SHALL BE SOLELY
RESPONSIBLE FOR THE INCLUSION OF ADEQUATE AMOUNTS TO COVER INSTALLATION OF ALL ITEMS INDICATED, DESCRIBED OR
IMPLIED.
THE ARCHITECT SHALL BE THE SOLE INTERPERTER OF THE SCOPE DOCUMENTS. DECISIONS OF THE ARCHITECT AS TO ITEMS OF
WORK WITHIN THE "SCOPE" OF THESE DRAWINGS SHALL BE FINAL.
CONTRACT ADMINISTRATION NOTE:
SHOULD SM7 DESIGN LLC NOT PERMORM CONTRACT ADMINISTRATION SERVICES FOR THIS PROJECT, THEN THE OWNER ASSUMES
ALL RESPONSIBILITY FOR INTERPERTATION OF THE CONTRACT DOCUMENTS AND FOR CONSTRUCTION OBSERVATION OR REVIEW AND
WAIVES ANY CLAIMS AGAINST SM7 DESIGN LLC THAT MAY BE IN ANY WAY CONNECTED THERETO.
ENVIRONMENTAL CONDITIONS NOTE:
OTHER HAZARDOUS SUBSTANCES, OR THE LIKELYHOOD OF THEIR PRESENCE ON THIS SET OF DRAWINGS IS NOT INTENDED TO MAKE
RECOMMENDATIONS REGARDING THE DETECTION OR REMOVAL OF ASBESTOS, LEAD OR ANY AND ALL HAZARDOUS MATERIALS.
HAZARDOUS MATERIAL DETECTION AND REMOVAL IS THE RESPONSIBILITY OF THE OWNER.
ABBREVIATIONS:
SYMBOLS:
1
A201
1
A402
1
2
3
4 A401
1
A501
DRAWING NUMBER
SHEET NUMBER
SECTION CUT
ELEVATION KEY
DETAIL KEY
INTERIOR ELEVATIONS
1
REVISION KEY
A
ABV.
ADJ.
A.F.F.
ALUM.
ALT.
ANG.
APPROX.
B
BD.
BLDG.
BLKG.
BM.
BSMT.
BOT.
C
CAB.
CL.
C.T.
CLG.
CLO.
CM.
CMU.
C.O.
COL.
CONC.
CONT.
D
DEPT.
DTL.
D.F.
DIA.
DIM.
DN.
DS.
DWG.
E
EA.
E.J.
EL.
ELEC.
EMER.
EQ.
EQUIP.
E.W.
E.
EXT.
F
F.D.
FL.
F.J.
FT.
G
GA.
GALV.
GYP.
H
H.B.
HCWD.
H.M.
HORIZ.
HGT.
L
LAM.
LAV.
LT.
M
MAS.
MAX.
MECH.
MEMB.
MET.
MFR.
MIN.
MISC.
M.O.
N
N.I.C.
#
N.T.S.
O
O.C.
O.D.
OPNG.
OPT.
P
P.C.
PL.
P. LAM
P.T.
PLYWD.
PR.
P.S.F.
P.S.I.
PTD.
P.V.C.
Q
QTY.
R
R.
RAD.
R.D.
REF.
REINF
REV.
REQD.
R.J.
RM
R.O.
S
SCHED.
SCWD
S.F.
SH.
SHT.
SIM.
S.M.P.
SPEC.
SQ.
S.S.
STD.
STL.
SUSP.
T
T.
TEL.
THK.
THRES.
THRU
T.O.P.
T.O.S.
T.O.SH.
T.O.SL.
TYP.
U/V
UON.
VCT.
VERT.
V.I.F.
W
W/
WD.
W/O
WP.
WT.
WWF
ABOVE
ADJACENT
ABOVE FINISH FLOOR
ALUMINUM
ALTERNATE
ANGLE
APPROXIMATE
BOARD
BUILDING
BLOCKING
BEAM
BASEMENT
BOTTOM
CABINET
CENTER LINE
CERAMIC TILE
CEILING
CLOSET
CENTIMETER
CONCRETE MASONRY
UNIT
CASED OPENING
COLUMN
CONCRETE
CONTINUOUS
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DOWN
DOWN SPOUT
DRAWING
NOT IN CONTRACT
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPENING
OPTIONAL
PRECAST
PLATE
PLASTIC LAMINATE
PRESSURE TREATED
PLYWOOD
PAIR
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAINTED
POLYVINYL CHLORIDE
QUANITY
RISER
RADIUS
ROOF DRAIN
REFRIGERATOR
REINFORCING
REVISION
REQUIRED
ROOF JOIST
ROOM
ROUGH OPENING
EACH
EXPANSION JOINT
ELEVATION
ELECTRICAL
EMERGENCY
EQUAL
EQUIPMENT
EACH WAY
EXISTING
EXTERIOR
FLOOR DRAIN
FLOOR
FLOOR JOIST
FOOT
GUAGE
GALVANIZED
GYPSUM BOARD
HOSE BIB
HOLLOW CORE WOOD
HOLLOW METAL
HORIZONTAL
HEIGHT
LAMINATE
LAVATORY
LIGHT
MASONRY
MAXIMUM
MECHANICAL
MEMBRANE
METAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
SCHEDULE
SOLID CORE WOOD
SQUARE FOOT
SHELF
SHEET
SIMILAR
SOLID MASONRT PIER
SPECIFICATION
SQUARE
STAINLESS STEAL
STANDARD
STEEL
SUSPENDED
TREAD
TELEPHONE
THICK
THRESHOLD
THROUGH
TOP OF PLATE
TOP OF STEEL
TOP OF SHEATHING
TOP OF SLAB
TYPICAL
UNLESS OTHERWISE
NOTED
VINYL COMPOSITION
TILE
VERTICAL
VERIFY IN FIELD
WITH
WOOD
WITHOUT
WATERPROOFING
WEIGHT
WELDED WIRE FABRIC
SITE
ENERGY CODE COMPLIANCE INFORMATION
MINIMUM INSULATION VALUES:
FLOOR:R-19
WALL: R-13
CEILING: R-30
FENESTRATION REQUIRMENTS:
U-FACTOR: 0.50
SHGC: 0.30
VICINITY MAP
Scale: NTS5
BUILDING CALCULATIONS
Conditioned Areas
First Floor 1,314 SF
Second Floor 1,290 SF
Third Floor 1,223 SF
Total Conditioned Area 3,827 SF
Garages 0 SF
Covered Areas, Screen Porches 0 SF
Exterior Decks, Stairs, Patios. Service Yards 0 SF
Pools 0 SF
Page 32
Section VII. Item #1.
A001
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
ARCHITECTURAL
SITE PLAN
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
SITE PLAN
Scale: 3/16" = 1'0"1
LINE TABLE
LABEL BEARING DISTANCE
L1 S 77°21'00" E 7.60'
1"
OTP
S77°21'00"E 59.00'(TIE)
1/2"
RBFD
1/2"
RBF
L1 (TIE)
233.03'
71.85'
S 18°50'29" W 304.88' (TOTAL)
RIGHT OF WAY
2 3/4"'
N12°39'00"E 29.00'(TIE)
BACK OF CURB
BACK OF CURB
APPROX. 130'
TO THE R/W OF
STATE OF
MIND STREET
STATE OF
MIND STREET
24.61''
PK NAIL SET
DATUM: NAVD 88
N77°21'00"W 51.00'
S12°39'00"W 26.00'
N12°39'00"E 26.00'
S77°21'00"E 51.00'
N18°57'27"W 15.26'
(TIE)
BLUFFTON ROAD (SC HWY 46)R/W VARIES
1,326 Sq.Ft. 0.030
Ac.
LOT 8
LOT 9
TMS R614 039 00A
0321 0000
LOT 7
TMS R614 039 00A
0319 0000
SN
SN
SN SN
1/2"
RBFD
15 LA
22 LA
22 P
8 G
JB
JB
T
1/2"
RBFD
1/2"
RBFD
1/2"
RBF
1/2"
RBFD
24.82
24.76
23.94
24.49
24.42
24.39
24.93
24.87
24.64
24.56
24.55
24.36
24.31
23.4623.47
24.02
24.00
23.97
24.3
24.224.2
24.0
24.0
24.4
24.3
24.4
24.3
EL.:
(DATUM)
BENCHMARK
24
PARKING LOT
CALHOUN ST.
DEVELOPMENT LLC.
TMS R614 039 00A 0018 0000
60X56 30X5230X52
D60X54
TRASHTRASH
CONDENSER UNITS
TRASH STORAGE
ELECTRICAL SERVICE AREA
SERVICE YARD
NEW 3-STORY
STRUCTURE
CONNECTION TO EXISTING
SIDEWALK
Page 33
Section VII. Item #1.
A002
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
LANDSCAPE PLAN
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
LANDSCAPE PLAN
Scale: 3/16" = 1'0"1
LINE TABLE
LABEL BEARING DISTANCE
L1 S 77°21'00" E 7.60'
1"
OTP
S77°21'00"E 59.00'(TIE)
1/2"
RBFD
1/2"
RBF
L1 (TIE)
233.03'
71.85'
S 18°50'29" W 304.88' (TOTAL)
RIGHT OF WAY
2 3/4"'
N12°39'00"E 29.00'(TIE)
BACK OF CURB
BACK OF CURB
APPROX. 130'
TO THE R/W OF
STATE OF
MIND STREET
STATE OF
MIND STREET
24.61''
PK NAIL SET
DATUM: NAVD 88
N77°21'00"W 51.00'
S12°39'00"W 26.00'
N12°39'00"E 26.00'
S77°21'00"E 51.00'
N18°57'27"W 15.26'
(TIE)
BLUFFTON ROAD (SC HWY 46)R/W VARIES
1,326 Sq.Ft. 0.030
Ac.
LOT 8
LOT 9
TMS R614 039 00A
0321 0000
LOT 7
TMS R614 039 00A
0319 0000
SN
SN
SN SN
1/2"
RBFD
15 LA
22 LA
22 P
8 G
JB
JB
T
1/2"
RBFD
1/2"
RBFD
1/2"
RBF
1/2"
RBFD
24.82
24.76
23.94
24.49
24.42
24.39
24.93
24.87
24.64
24.56
24.55
24.36
24.31
23.4623.47
24.02
24.00
23.97
24.3
24.224.2
24.0
24.0
24.4
24.3
24.4
24.3
EL.:
(DATUM)
BENCHMARK
24
PARKING LOT
CALHOUN ST.
DEVELOPMENT LLC.
TMS R614 039 00A 0018 0000
60X56 30X5230X52
D60X54
TRASHTRASH
52 CAREX EUERILLO
15 FOXTAIL FERNS
EXISTING TREES
15 SF ANNUAL BED
12 WINTERGREEN BOXWOOD
15 SF ANNUAL BED
3 WINTERGREEN BOXWOOD
5 FOXTAIL FERNS
10 CAREX EUERILLO
1 PODOCARPUS
3 OSMANTHUS TEA OLIVE
1 ITALIAN CYPRESS
5 WINTERGREEN BOXWOOD
1 PYRAMIDAL BOXWOOD
1 ITALIAN CYPRESS
5 WINTERGREEN BOXWOOD
1 PYRAMIDAL BOXWOOD
5 CAREX EUERILLO
5 WINTERGREEN BOXWOOD
3 CAREX EUERILLO
EXISTING TREE
PLANT SC HEDULE
QTY. SIZE PLANT C OMMENT
70 1 G C AREX EVERILLO
20 3 G FOXTAIL FERN
58 4.5" ANNUAL FLOWERS DISTRIBUTE IN TWO BEDS
24 7 G BOXWOOD WINTERG REEN
3 1 5 G TEA OLIVE
1 1 5 G PODOC ARPUS
2 30 G ITALIAN C YPRESS
2 30-36" BOXWOOD PYRAMIDAL
LANDSCAPE DESIGN BY: PETE KNAPIK
Page 34
Section VII. Item #1.
201
201
202
203
FOYER
5'0"x 4'6" +/-
GREAT. RM
15'6"x 15'6" +/-KITCHEN
9'0"x 14'0" +/-
SECOND FLOOR
1,320 s.f. +/-
UTILTY. RM
5'6"x 6'0" +/-
BATH. RM
5'0"x 9'0" +/-
clos.
linen
clos.
BED. RM
12'0"x 12'0" +/-
BED. RM
12'0"x 12'0" +/-
BATH. RM
5'0"x 9'0" +/-
elevator
pntr.
PORCH
18'0"x 8'0" +/-
PORCH
15'0"x 10'0" +/-
built-inbuilt-in
D D
G
G
F
F
G
10'-8 1/2" 14'-8" 7 1/2"
5'-6" 26'-0"
10'-4"51'-0"6'-5"
3'-9" 18'-6" 3'-9"
5'-6" 26'-0"
24'-6"12'-0"14'-6"
10'-4"51'-0"6'-5"
31'-6"
67'-9"
31'-6"
67'-9"
12'-11"3'-6"5'-7"12'-11"16'-1"
22'-7" 2'-8"7'-9"
6'-5" 4'-1" 15'-6"
4'-3" 2'-3" 11'-6" 2'-0" 6'-0"
6'-6" 5'-5" 14'-1"
8'-6" 9'-6" 8'-0"
10'-8"17'-4"5'-0"18'-0"
18'-0"
F
7'-6" 5'-6" 5'-6" 7'-6"
1
A401
2
A401
1
A402
2
A402
A101
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
FIRST / SECOND
FLOOR PLAN
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
60X56 30X5230X52
D60X54
TRASHTRASH
OFFICE
9'0"x 9'6" +/-
MEETING RM.
9'0"x 9'6" +/-
CONF. RM
10'6"x 14'0" +/-
WORK. RM
15'0"x 11'0" +/-
RECEPT. OFFICE
9'0"x 9'6" +/-
WAITING. AREA
11'0"x 10'6" +/-
kitchenette
copiers
FIRST FLOOR
1,320 s.f. +/-
riser rm.
mech
. rm.
storage
clos.
OFFICE
9'0"x 9'0" +/-
closetFOYER
5'0"x 9'0" +/-
elevator
COVERED ENTRY
18'0"x 8'0" +/-
SERVICE
YARD
A
A
B
C
C
C
C
B
CONDENSER
UNIT
CONDENSER
UNIT
CONDENSER
UNIT
ELECTIRCAL
SERVICE
101
102103
5'-4"1'-2"
1'-2" 16'-4" 1'-2"
5'-4"1'-2"
10'-4"51'-0"6'-6"
26'-0"5'-6"
67'-10"
31'-6"
5'-0"7'-6"8'-6"24'-4"5'-8"
10'-4"51'-0"6'-6"
9'-11"15'-8"14'-0"11'-5"
9'-10" 4'-7" 11'-7"
5'-11"4'-0"7'-1"4'-0"10'-3"9'-6"10'-3"
5'-1" 7'-0"
10'-8 1/2" 14'-8" 7 1/2"
5'-6" 22'-4" 3'-8"
67'-10"
31'-6"
12'-6"5'-1"8'-5"
7'-6" 5'-6" 5'-6" 7'-6"
1
A401
2
A401
1
A402
2
A402
SECOND FLOOR PLAN
Scale: 1/4"= 1'0"1FIRST FLOOR PLAN
Scale: 1/4"= 1'0"2
Page 35
Section VII. Item #1.
A102
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
THIRD FLOOR /
ROOF PLAN
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
F
10'-8 1/2" 14'-8" 7 1/2"
26'-0"
10'-4"51'-0"6'-5"
67'-9"
3'-9" 18'-6" 3'-9"
10'-4"51'-0"6'-5"
67'-9"
26'-0"
16'-9"
2'-9"9'-5"4'-9"34'-1"
7'-6"5'-6"5'-6"7'-6"
8'-6" 9'-6" 8'-0"15'-5"3'-6"7'-4"4'-9"20'-0"
6'-6"4'-0"5'-0"4'-0"2'-3"4'-3"
6'-0"8'-6"5'-0"6'-6"
5'-11"6'-1"8'-2"3'-11"5'-11"21'-0"
4'-1" 8'-0"
27'-6"6'-9"
BATH. RM
9'0"x 12'0" +/-
GREAT. RM
15'0"x 19'0" +/-
BED. RM
14'0"x 14'6" +/-
KITCHEN
10'0"x 12'0" +/-
THIRD FLOOR
1,320 s.f. +/-
w.c.
W/D
FOYER
5'0"x 7'0" +/-
PWD. RM
5'6"x 5'6" +/-
elevator
PORCH
18'0"x 8'0" +/-
PORCH
15'0"x 10'0" +/-
o.c.
W.I.C.
4'6"x 8'0" +/-
F
F
F
D D
G
G
breakfast
6'0"x 7'0" +/-
a.c.
G 301
301
1
A401
2
A401
1
A402
2
A402
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-4"
O.H.
1'-0"
O.H.
3'-8"
O.H.
1'-0"
O.H.
3'-8"
O.H.
7:12
7:12
7:12
7:12
4:12
4:12
4:12
4:12
4:12
4:12
2.5:12
RIDGE
RIDGE
HIP HIP
HIP
HIP
HIP
HIP
HIP
HIP
VALLEY VALLEY
ARCHITECTURAL
SINGLE ROOF
METAL ROOF
METAL ROOF
METAL ROOF
1
A401
2
A401
1
A402
2
A402
ROOF PLAN
Scale: 1/4"= 1'0"1THIRD FLOOR PLAN
Scale: 1/4"= 1'0"2
Page 36
Section VII. Item #1.
A201
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
ELEVATIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
FRONT ELEVATION
Scale: 1/4" = 1'-0"2
ELEVATION GENERAL NOTES
1. ALL SIDING MATIEALS TO BE INSTALLED AND FLASHED
PER MANUFACTURER'S SPECIFICATIONS.
2. ALL ROOFING MATERIALS TO BE INSTALLED AND
FLASHED PER MANUFATURE'S SPECIFICATIONS.
3. ALL WOOD PRODUCTS EXPOSED TO WEATHER SHALL
BE PRESSURE TREATED.
4. SEE ROOF PLAN FOR ADDITIONAL INFORMATION
CONCERNING ROOF OVERHANGS AND OTHER ROOF
RELATED ITEMS.
5. GUTTERS AND DOWNSPOUTS HAVE NOT BEEN SHOWN.
CONTRACTOR TO VERIFY LOCATIONS WITH OWNER.
6. CONTRACTOR TO VERIFY FINAL MATERIAL AND COLOR
SELECTION WITH OWNER.
REAR ELEVATION
Scale: 1/4" = 1'-0"1
BRICK, RUNNING BOND
PATTERN
TOP OF PLATE
SECOND FLOOR
TOP OF PLATE
THIRD FLOOR
TOP OF PLATE
PEAK OF ROOF
TOP OF SLAB
11'-0" 2'-0" 10'-0" 2'-0" 9'-6"
13'-0" 12'-0"
+/- 42'-11"
HORIZONTAL HARDIE
LAP SIDING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
ARCHITECTURAL
SINGLE ROOF
METAL ROOF
8'-0"
WIN./DOOR HEAD
8'-0"
WIN./DOOR HEAD
12
7
12" WOOD COLUMN
WITH CAP AND BASE
8'-0"
WIN./DOOR HEAD
12
4
HORIZONTAL WOOD
SCREENING
12" WOOD COLUMN
WITH CAP AND
BASE
BRICK WATER TABLE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
6x6 WOOD BRACKET
EXPOSED WOOD
RAFTER TAILS AT
PORCHES
BRICK
12
7
TOP OF PLATE
SECOND FLOOR
TOP OF PLATE
THIRD FLOOR
TOP OF PLATE
PEAK OF ROOF
HOUSE SLAB
11'-0" 2'-0" 10'-0" 2'-0" 9'-6"
13'-0" 12'-0"
+/- 42'-11"
ARCHITECTURAL
SHINGLE ROOF
METAL ROOF
8'-0"
WIN./DOOR HEAD
8'-0"
WIN./DOOR HEAD
12
4
8'-0"
WIN./DOOR HEAD
METAL ROOF
HORIZONTAL HARDIE LAP
SIDING
12
4
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
HORIZONTAL WOOD
SCREENING
12" WOOD COLUMN
WITH CAP AND
BASE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
Page 37
Section VII. Item #1.
A202
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
ELEVATIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
RIGHT ELEVATION
Scale: 1/4" = 1'-0"1
ELEVATION GENERAL NOTES
1. ALL SIDING MATIEALS TO BE INSTALLED AND FLASHED
PER MANUFACTURER'S SPECIFICATIONS.
2. ALL ROOFING MATERIALS TO BE INSTALLED AND
FLASHED PER MANUFATURE'S SPECIFICATIONS.
3. ALL WOOD PRODUCTS EXPOSED TO WEATHER SHALL
BE PRESSURE TREATED.
4. SEE ROOF PLAN FOR ADDITIONAL INFORMATION
CONCERNING ROOF OVERHANGS AND OTHER ROOF
RELATED ITEMS.
5. GUTTERS AND DOWNSPOUTS HAVE NOT BEEN SHOWN.
CONTRACTOR TO VERIFY LOCATIONS WITH OWNER.
6. CONTRACTOR TO VERIFY FINAL MATERIAL AND COLOR
SELECTION WITH OWNER.
12
7
TOP OF PLATE
SECOND FLOOR
TOP OF PLATE
THIRD FLOOR
TOP OF PLATE
PEAK OF ROOF
HOUSE SLAB
11'-0" 2'-0" 10'-0" 2'-0" 9'-6"
13'-0" 12'-0"
42'-11 3/8"
8'-0"
WIN. HEAD
8'-0"
WIN. HEAD
8'-0"
WIN. HEAD
12
2.5
12
4
10'-6"
WIN. HEAD
BRICK, RUNNING BOND
PATTERN
HORIZONTAL HARDIE
LAP SIDING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
ARCHITECTURAL
SINGLE ROOF
12" WOOD COLUMN
WITH CAP AND BASE
BRICK WATER TABLE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
6x6 WOOD BRACKET
HORIZONTAL WOOD
SCREENING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
METAL ROOF
EXPOSED WOOD
RAFTER TAILS AT
PORCHES
BRICK COLUMN
12" WOOD COLUMN
WITH CAP AND BASE
Page 38
Section VII. Item #1.
A203
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
ELEVATIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
12
7
TOP OF PLATE
SECOND FLOOR
TOP OF PLATE
THIRD FLOOR
TOP OF PLATE
PEAK OF ROOF
HOUSE SLAB
9'-6"2'-0"10'-0"2'-0"11'-0"
12'-0"13'-0"
+/- 42'-11"
8'-0"
WIN. HEAD
8'-0"
WIN./DOOR HEAD
8'-0"
WIN. HEAD
10'-6"
WIN. HEAD
12
4
BRICK, RUNNING BOND
PATTERN
HORIZONTAL HARDIE
LAP SIDING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
ARCHITECTURAL
SINGLE ROOF
12" WOOD COLUMN
WITH CAP AND BASE
BRICK WATER TABLE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
6x6 WOOD BRACKET
HORIZONTAL WOOD
SCREENING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
POWDER COATED
ALUMINUM RAILS
AND PICKETS
12" WOOD COLUMN
WITH CAP AND BASE
METAL ROOF
EXPOSED WOOD
RAFTER TAILS AT
PORCHES
12" WOOD COLUMN
WITH CAP AND BASE
12
4
12
2.5
LEFT ELEVATION
Scale: 1/4" = 1'-0"1
ELEVATION GENERAL NOTES
1. ALL SIDING MATIEALS TO BE INSTALLED AND FLASHED
PER MANUFACTURER'S SPECIFICATIONS.
2. ALL ROOFING MATERIALS TO BE INSTALLED AND
FLASHED PER MANUFATURE'S SPECIFICATIONS.
3. ALL WOOD PRODUCTS EXPOSED TO WEATHER SHALL
BE PRESSURE TREATED.
4. SEE ROOF PLAN FOR ADDITIONAL INFORMATION
CONCERNING ROOF OVERHANGS AND OTHER ROOF
RELATED ITEMS.
5. GUTTERS AND DOWNSPOUTS HAVE NOT BEEN SHOWN.
CONTRACTOR TO VERIFY LOCATIONS WITH OWNER.
6. CONTRACTOR TO VERIFY FINAL MATERIAL AND COLOR
SELECTION WITH OWNER.
Page 39
Section VII. Item #1.
A204
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
ELEVATIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
FRONT ELEVATION
Scale: 1/4" = 1'-0"2
ELEVATION GENERAL NOTES
1. ALL SIDING MATIEALS TO BE INSTALLED AND FLASHED
PER MANUFACTURER'S SPECIFICATIONS.
2. ALL ROOFING MATERIALS TO BE INSTALLED AND
FLASHED PER MANUFATURE'S SPECIFICATIONS.
3. ALL WOOD PRODUCTS EXPOSED TO WEATHER SHALL
BE PRESSURE TREATED.
4. SEE ROOF PLAN FOR ADDITIONAL INFORMATION
CONCERNING ROOF OVERHANGS AND OTHER ROOF
RELATED ITEMS.
5. GUTTERS AND DOWNSPOUTS HAVE NOT BEEN SHOWN.
CONTRACTOR TO VERIFY LOCATIONS WITH OWNER.
6. CONTRACTOR TO VERIFY FINAL MATERIAL AND COLOR
SELECTION WITH OWNER.
REAR ELEVATION
Scale: 1/4" = 1'-0"1
12
7
TOP OF PLATE
SECOND FLOOR
TOP OF PLATE
THIRD FLOOR
TOP OF PLATE
PEAK OF ROOF
HOUSE SLAB
11'-0" 2'-0" 10'-0" 2'-0" 9'-6"
13'-0" 12'-0"
+/- 42'-11"
WOOD RAILS AND
PICKETS
12" WOOD COLUMN WITH
CAP AND BASE
METAL ROOF
8'-0"
WIN./DOOR HEAD
8'-0"
WIN./DOOR HEAD
8'-0"
WIN./DOOR HEAD
HORIZONTAL HARDIE LAP
SIDING
12
4
P L A T EL IN EP L A T EL IN E
12
4
HORIZONTAL LAP
SIDING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
ARCHITECTURAL
SINGLE ROOF
HARDIE TRIM TO
MATCH COLUMN
PROFILE
12" WOOD COLUMN
WITH CAP AND BASE
HORIZONTAL HARDIE
LAP SIDING
POWDER COATED
ALUMINUM RAILS
AND PICKETS
HORIZONTAL WOOD
SCREENING
ELECTRICAL SERVICE
MOUNTING AREA
CONDENSER UNITS
SECTION THROUGH REAR PORCH
Scale: Actual Size1
Page 40
Section VII. Item #1.
A401
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
WALL SECTIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
8'-2"1'-10 3/4"10'-2"1'-10 3/4"11'-0"
T.O. SLAB
0"
T.O. PLATE
11'-0"
T.O. FLOOR
13'-0"
T.O. PLATE
23'-0"
T.O. FLOOR
25'-0"
T.O. PLATE
34'-6"
9'-6"2'-0"10'-0"2'-0"11'-0"
T.O. SLAB
0"
T.O. PLATE
34'-6"
9'-6"2'-0"10'-0"2'-0"11'-0"
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL HARDIE SIDING
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL HARDIE SIDING
ENGINEERED FLOOR SYSTEM, 1 HR.
ASSEMBLY, REF. UL DESIGN NUMBER
L521
ENGINEERED FLOOR SYSTEM, 1 HR.
ASSEMBLY, REF. UL DESIGN NUMBER
L521
FRIST FLOOR WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- BRICK VENEER
TYPICAL ROOF CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x12 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- ARCHITECTURAL SHINGLES
PLATE
LINE
PLATE
LINE
PLATE
LINE
T.O. SLAB
0"
T.O. COL.
11'-0"
T.O. PORCH
12'-10.75"
T.O. COL.
23'-0 3/4"
T.O. PORCH
24'-11.5"
T.O. COL.
33'-1 1/2"
T.O. BEAM
34'-0 3/4"
11 1/4"
34'-0 3/4"
34'-6"
REAR PORCH SECTION
Scale: 1/2" = 1'-0"1TYPICAL WALL SECTION
Scale: 1/2" = 1'-0"2
T.O. PLATE
23'-0"
T.O. FLOOR
25'-0"
5
A501 SIM
T.O. PLATE
11'-0"
T.O. FLOOR
13'-0"
TYPICAL PORCH ROOF CONSTRUCTION:
- INT. GYP
- 2x8 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- METAL ROOF
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL PORCH CONSTRUCTION:
- 2x8 JOIST
- 1x4 HARDIE TRIM
- BEAM WITH FINISH HARDIE TRIM
- 1x10 HARDIE TRIM
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL BRICK SIDING
ENGINEERED FLOOR
SYSTEM, 1 HR. ASSEMBLY,
REF. UL DESIGN NUMBER
L521
ENGINEERED FLOOR
SYSTEM, 1 HR. ASSEMBLY,
REF. UL DESIGN NUMBER
L521
TYPICAL ROOF CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x12 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- ARCHITECTURAL SHINGLES
3
A501
2
A501
1
A501
4
A501
5
A501
6
A501
Page 41
Section VII. Item #1.
A402
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
WALL SECTIONS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
T.O. SLAB
0"
T.O. PLATE
11'-0"
T.O. FLOOR
13'-0"
T.O. PLATE
23'-0"
T.O. FLOOR
25'-0"
T.O. PLATE
34'-6"
9'-6"2'-0"10'-0"2'-0"11'-0"
PLATE
LINE
34'-6"
PLATE
LINE
PLATE
LINE
T.O. SLAB
0"
T.O. PLATE
11'-0"
T.O. FLOOR
13'-0"
T.O. PLATE
23'-0"
T.O. FLOOR
25'-0"
T.O. PLATE
34'-6"
9'-6"2'-0"10'-0"2'-0"11'-0"
PLATE
LINE
34'-6"
PLATE
LINE
PLATE
LINE
8'-2"1'-10 3/4"10'-2"1'-10 3/4"11'-0"
T.O. SLAB
0"
T.O. COL.
11'-0"
T.O. PORCH
12'-10.75"
T.O. COL.
23'-0 3/4"
T.O. COL.
33'-1 1/2"
T.O. BEAM
34'-0 3/4"
11 1/4"
34'-0 3/4"
T.O. PORCH
24'-11.5"
4
A502 SIM
3
A502 SIM
FRONT PORCH SECTION AT WINDOW
Scale: 1/2" = 1'-0"1FRONT PORCH SECTION AT COLUMN
Scale: 1/2" = 1'-0"2
8'-2"1'-10 3/4"10'-2"1'-10 3/4"11'-0"
T.O. SLAB
0"
T.O. COL.
11'-0"
T.O. PORCH
12'-10.75"
T.O. COL.
23'-0 3/4"
T.O. COL.
33'-1 1/2"
11 1/4"
34'-0 3/4"
T.O. PORCH
24'-11.5"
T.O. BEAM
34'-0 3/4"
TYPICAL PORCH CONSTRUCTION:
- 2x8 JOIST
- 1x4 HARDIE TRIM
- BEAM WITH FINISH HARDIE TRIM
- 1x10 HARDIE TRIM
TYPICAL PORCH ROOF CONSTRUCTION:
- INT. GYP
- 2x8 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- METAL ROOF
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL HARDIE SIDING
ENGINEERED FLOOR SYSTEM, 1 HR.
ASSEMBLY, REF. UL DESIGN NUMBER
L521
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL HARDIE SIDING
ENGINEERED FLOOR SYSTEM, 1 HR.
ASSEMBLY, REF. UL DESIGN NUMBER
L521
TYPICAL PORCH CONSTRUCTION:
- 2x8 JOIST
- 1x4 HARDIE TRIM
- BEAM WITH FINISH HARDIE TRIM
- 1x10 HARDIE TRIM
TYPICAL WALL CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x6 STUDS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- HORIZONTAL BRICK SIDING
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL PORCH CONSTRUCTION:
- 2x8 JOIST
- 1x4 HARDIE TRIM
- BEAM WITH FINISH HARDIE TRIM
- 1x10 HARDIE TRIM
TYPICAL COLUMN CONSTRUCTION:
- 5/4x8 WOOD TRIM CAP
- HOLLOW WOOD SHAFT
- 5/4x10 WOOD BASE
TYPICAL PORCH CONSTRUCTION:
- 2x8 JOIST
- 1x4 HARDIE TRIM
- BEAM WITH FINISH HARDIE TRIM
- 1x10 HARDIE TRIM
ENGINEERED FLOOR
SYSTEM, 1 HR. ASSEMBLY,
REF. UL DESIGN NUMBER
L521
ENGINEERED FLOOR
SYSTEM, 1 HR. ASSEMBLY,
REF. UL DESIGN NUMBER
L521
TYPICAL PORCH ROOF CONSTRUCTION:
- INT. GYP
- 2x8 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- METAL ROOF
TYPICAL ROOF CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x12 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- ARCHITECTURAL SHINGLES
TYPICAL ROOF CONSTRUCTION:
- INT. GYP
- INSULATION
- 2x12 RAFTERS AT 16" O.C.
- EXTERIOR ZIP SYSTEM
- ARCHITECTURAL SHINGLES
4
A502
3
A502 SIM
2
A502
1
A503
2
A503
3
A503
Page 42
Section VII. Item #1.
A501
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
DETAILS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
PLATE
LINE
TYPICAL ROOF DETAIL
Scale: 1" = 1'-0"3
5/4 HARDIE TRIM, O.H.
SOFFIT 1/2"
ARCHITECTURAL SHINGLES
OVER UNDERLAYMENT
SHEATHING
V-GROOVE SOFFIT
2x6 HARDIE TRIM, ALIGN
WITH WINDOW TRIM
RAFTER
INSULATION
5/4x6 HARDIE TRIM
1x4 HARDIE TRIM
METAL DRIP
BLOCKING
HURRICANE STRAP
INTERIOR FINISH
INSULATION
HORIZONTAL HARDIE SIDING
TYPICAL SECOND FLOOR DETAIL
Scale: 1" = 1'-0"2
1/2"
1/2"
1/2"
BRICK SOLDIER COURSE
BRICK CAP, 15 DEG. ANGLE
HORIZONTAL HARDIE SIDING
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
INSULATION
BRICK TIES
BRICK VENEER
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
INSULATION
FLASHING SET IN SEALANT
5/4x4 HARDIE TRIM
INTERIOR FINISH
INTERIOR FINISH
TYPICAL WALL FOUNDATION
Scale: 1" = 1'-0"1
CONCRETE FOUNDATION
PER STRUCTURAL
DRAWINGS
BRICK SOLIDER COURSE
FILL CAVITY WITH GROUT
BELOW FLASHING
SELF ADHEARING FLASHING
OVER SHEATHING
BRICK WATERTABLE:
FTW-01-4 STRETCHER
BRICK TIES
BRICK VENEER
+/- 1'-1 3/8"
5 COURSES
ZIP SYSTEM SHEATHING
INSULATION
FLASHING AND WEEPS
2x6 WALL CONSTRUCTION
FOUNDATION AT REAR PORCH
Scale: 1" = 1'-0"4
1x6 HORIZONTAL WOOD
BOARDS AT 6 1/2" O.C. OVER
PT 2x4 FRAMING
PT BLOCKING AT 16" O.C.
WOOD COLUMN BEYOND
CONCRETE SLAB, SLOPE
AWAY FROM BUILDING 1/8"
PER FOOTINTERIOR FINISH
CONCRETE FOUNDATION
PER STRUCTURAL
DRAWINGS
BRICK SOLIDER COURSE
FILL CAVITY WITH GROUT
BELOW FLASHING
SELF ADHEARING FLASHING
OVER SHEATHING
BRICK WATERTABLE:
FTW-01-4 STRETCHER
BRICK TIES
BRICK VENEER
ZIP SYSTEM SHEATHING
INSULATION
2x6 WALL CONSTRUCTION
FLASHING AND WEEPS
REAR PORCH AT SECOND FLOOR
Scale: 1" = 1'-0"5
1x6 HORIZONTAL WOOD
BOARDS AT 6 1/2" O.C. OVER
PT 2x4 FRAMING
1X10 HARDIE TRIM
WOOD BEAM
WRAP BEAM IN FINISH
HARDIE MATERIAL
1'-0 1/4"
1X4 HARDIE TRIM
POWDER COATED
ALUMINUM RAIL
FLASHING FOR DRAINAGE
ICE/WATER SHIELD OVER
3/4" SHEATHING
FINISH DEKING OVER
SLEEPERS
2x8 JOIST, RIP TOP FOR 1/8"
PER FOOT SLOPE
EXTEND ICE/WATER SHIELD
UNDER THRESHOLD
HARDIE TRIM TO MATCH
BEAM DEPTH
LEDGER
DOOR PER SCHEDULE
5/4 HARDIE TRIM
2x8 JOIST, RIP TOP FOR 1/8"
PER FOOT SLOPE
ENGINEERS FLOOR SYSTEM
INTERIOR FINISH
V-GROOVE CEILING
INSULATION
BRICK TIES
BRICK VENEER
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
WOOD COLUMN BEYOND
WOOD COLUMN BEYOND
PLATE
LINE
PLATE
LINE
REAR PORCH AT ROOF
Scale: 1" = 1'-0"6
INTERIOR FINISH
METAL ROOF OVER
UNDERLAYMENT
SHEATHING
BEAM
WRAP BEAM IN FINISH
HARDIE MATERIAL
RAFTER
CEILING JOISTS
1x6 HARDIE TRIM, ALIGN
WITH TYP. WALL TRIM
2x4 HARDIE FASCIA
METAL DRIP
BLOCKING
HURRICANE STRAP
11 1/4"
7 1/4"
1'-4"
2x6 HARDIE TRIM, ALIGN
WITH WINDOW TRIM
5/4x6 HARDIE TRIM
DOOR PER SCHEDULE
V-GROOVE SOFFIT
V-GROOVE CEILING
WOOD COLUMN BEYOND
SIMPSON STRAP
ARCHITECTURAL SHINGLE
ROOF OVER
UNDERLAYMENT
TRANSITION FLASHING
SHEATHING
RAFTER
BLOCKING
INSULATUON
Page 43
Section VII. Item #1.
A502
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
DETAILS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
PLATE
LINE
PLATE
LINE
PLATE
LINE
FRONT PORCH ROOF DETAIL
Scale: 1" = 1'-0"4
INTERIOR FINISH
METAL ROOF OVER
UNDERLAYMENT
SHEATHING
WOOD BEAM
WOOD BRACKET
RAFTER
CEILING JOISTS
2x4 HARDIE FASCIA
METAL DRIP
HURRICANE STRAP
9 1/2"
1'-4 1/2"
2x6 HARDIE TRIM, ALIGN
WITH WINDOW TRIM
5/4x6 HARDIE TRIM
BLOCKING
5 1/2"
1x6 HARDIE TRIM
SIMPSON STRAP
ARCHITECTURAL SHINGLE
ROOF OVER
UNDERLAYMENT
TRANSITION FLASHING
SHEATHING
RAFTER
BLOCKING
INSULATUON
5/4x8 WOOD TRIM
WRAP BEAM TO MATCH COL.
WIDTH, BLOCK AS REQ'D
11 1/4"
HOLLOW WOOD COLUMN
V-GROOVE SOFFIT
V-GROOVE CEILING
INSULATION
2x6 WALL CONSTRUCTION
HORIZONTAL HARDIE SIDING
FRONT PORCH DETAIL AT THIRD FLOOR
Scale: 1" = 1'-0"3
1X10 HARDIE TRIM
WOOD BEAM
WRAP BEAM IN FINISH
HARDIE MATERIAL
1'-0 1/4"
1X4 HARDIE TRIM
FLASHING FOR DRAINAGE
ICE/WATER SHIELD OVER
3/4" SHEATHING
FINISH DECKING OVER
SLEEPERS
HARDIE TRIM TO MATCH
BEAM DEPTH
WOOD LEDGER
5/4 HARDIE TRIM
2x8 JOIST, RIP TOP FOR 1/8"
PER FOOT SLOPE
ENGINEERED FLOOR
SYSTEM
INTERIOR FINISH
5/4X10 TRIM
HOLLOW STRUCTURAL
WOOD COLUMN
5/4X10 WOOD TRIM
5/4X8 WOOD TRIM
V-GROOVE CEILING
HOLLOW STRUCTURAL
WOOD COLUMN
INSULATION
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
HORIZONTAL HARDIE SIDING
FRONT PORCH DETAIL AT SECOND FLOOR
Scale: 1" = 1'-0"2
1X10 HARDIE TRIM
WOOD BEAM
WRAP BEAM IN FINISH
HARDIE MATERIAL
1X4 HARDIE TRIM
FLASHING FOR DRAINAGE
HARDIE TRIM TO MATCH
BEAM DEPTH
WOOD LEDGER
5/4 HARDIE TRIM
2x8 JOIST, RIP TOP FOR 1/8"
PER FOOT SLOPE
ENGINEERED FLOOR
SYSTEM
INTERIOR FINISH
HOLLOW STRUCTURAL
WOOD COLUMN
2x6 FRAMING
BRICK VENEER
1'-0 1/4"
ICE/WATER SHIELD OVER
3/4" SHEATHING
FINISH DECKING OVER
SLEEPERS
5/4X10 WOOD TRIM
V-GROOVE CEILING
INSULATION
BRICK TIES
BRICK VENEER
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
HORIZONTAL HARDIE SIDING
PLATE
LINE
BRACKET DETAIL
Scale: 1" = 1'-0"1
FLASHING
2x8 WOOD BLOCKING
METAL ROOF
2x8 WOOD RAFTERS
METAL DRIP
2x4 HARDIE FASCIA
6x8 WOOD BEAM
6x6 WOOD BRACKET
2x8 WOOD TRIM WITH
CHAMFERED EDGES
BLOCKING FOR
CONNECTION
3"
3"
3'-0" OH
BTM OF BEAM
+9'-0" AFF
V-GROOVE SOFFIT
INSULATION
BRICK TIES
BRICK VENEER
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
Page 44
Section VII. Item #1.
A503
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
DETAILS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
FRONT PORCH DETAIL AT COLUMN
Scale: 1" = 1'-0"1
CONCRETE FOUNDATION
PER STRUCTURAL
DRAWINGS
BRICK SOLIDER COURSE
FILL CAVITY WITH GROUT
BELOW FLASHING
SELF ADHEARING FLASHING
OVER SHEATHING
BRICK WATERTABLE:
FTW-01-4 STRETCHER
BRICK TIES
BRICK VENEER
+/- 1'-1 3/8"
5 COURSES
ZIP SYSTEM SHEATHING
INSULATION
FLASHING AND WEEPS
2x6 WALL CONSTRUCTION
BRICK SOLIDER COURSE
BRICK WATERTABLE:
FTW-01-4 STRETCHER
ZIP SYSTEM SHEATHING
2x6 WALL CONSTRUCTION
CONCRETE SLAB, SLOPE
AWAY FROM BUILDING 1/8"
PER FOOT
BRICK VENEER
TYPICAL WINDOW SILL TRIM DETAIL
Scale: 1" = 1'-0"2
WINDOW PER SCHEDULE
INTERIOR FINISH
CONCRETE FOUNDATION
PER STRUCTURAL
DRAWINGS
CONCRETE SLAB, SLOPE
AWAY FROM BUILDING 1/8"
PER FOOT
BRICK COLUMN BEYOND
FRONT PORCH DETAIL AT SECOND FLOOR
Scale: 1" = 1'-0"3
WINDOW PER SCHEDULE
2x12 HARDIE TRIM, ALIGN
WITH WINDOW TRIM
INTERIOR FINISH
1X10 HARDIE TRIM
WOOD BEAM
WRAP BEAM IN FINISH
HARDIE MATERIAL
1'-0 1/4"
1X4 HARDIE TRIM
FLASHING FOR DRAINAGE
ICE/WATER SHIELD OVER
3/4" SHEATHING
FINISH DECKING OVER
SLEEPERS
HARDIE TRIM TO MATCH
BEAM DEPTH
WOOD LEDGER
5/4 HARDIE TRIM
2x8 JOIST, RIP TOP FOR 1/8"
PER FOOT SLOPE
ENGINEERED FLOOR
SYSTEM
HOLLOW STRUCTURAL
WOOD COLUMN
BRICK COLUMN BEYOND
POWDER COATED
ALUMINUM RAIL
INTERIOR FINISH
V-GROOVE CEILING
Page 45
Section VII. Item #1.
A504
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
DETAILS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
EXTERIOR CORNER
EXTERIOR ZIP SYSTEM
SHEATHING
INTERIOR CORNER
WEATHER RESISTANT
BARRIER
SMOOTH HARDIE PANEL
CORNER TRIM: BOARD AND BATTEN SIDING
Scale: 3" = 1'-0"1
1'-4"
ON CENTER (TYP)
1x3 AT 16" ON CENTER
2 1/2"
2 1/2"
2 1/2"
2 1/2"
EXTERIOR ZIP SYSTEM
SHEATHING
WEATHER RESISTANT
BARRIER
SMOOTH HARDIE PANEL
1x3 AT 16" ON CENTER
EXTERIOR CORNER
EXTERIOR ZIP SYSTEM
SHEATHING
INTERIOR CORNER
WEATHER RESISTANT
BARRIER
CORNER HORIZONTAL SIDING
Scale: 3" = 1'-0"2
1x3 AT 16" ON CENTER
EXTERIOR ZIP SYSTEM
SHEATHING
WEATHER RESISTANT
BARRIER
SMOOTH HARDIE SIDING
5/4 x 5/4 HARDIE TRIM
5/4 x 6 HARDIE TRIM
SMOOTH HARDIE SIDING
5 1/2"
5 1/2"
Page 46
Section VII. Item #1.
A505
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
DETAILS
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
5/4 AT 15 DEGREE
ANGLE, HARDIE
OVERHANG TRIM 1/2"
2x6 HARDIE HEAD TRIM
1/2"
1"
5/4x4 HARDIE TRIM AT
SILL
5/4x4 HARDIE TRIM AT
JAMB
NOTE: WINDOW AND DOOR DETAILS PROVIDED FOR TRIM
PROFILES ONLY. SEE MANUFACTURE'S INSTALLATION
REQUIREMENTS AND INSTRUCTION FOR FLASHING AND
WATERPROOFING DETAILS.
PARTIAL WINDOW TRIM ELEVATION
Scale: 3" = 1'-0"1
2
A503
2
A503
2
A503
2
A503
2
A503
WINDOW PER SCHEDULE
INTERIOR TRIM, VERIFY
WITH OWNER
TYPICAL WINDOW SILL TRIM DETAIL
Scale: 3" = 1'-0"3
HARDIE SIDING
MOISTURE BARRIER AND
EXTERIOR ZIP SYSTEM
SHEATHING
INSULATION
5/4x4 HARDIE TRIM AT SILL
INTERIOR FINISH
BLOCKING AS REQUIRED
BACKER ROD AND SEALANT
2x SILL PLATE
NOTE: WINDOW AND DOOR DETAILS PROVIDED FOR TRIM
PROFILES ONLY. SEE MANUFACTURE'S INSTALLATION
REQUIREMENTS AND INSTRUCTION FOR FLASHING AND
WATERPROOFING DETAILS.
5/4x4 HARDIE TRIM AT JAMB
INTERIOR TRIM, VERIFY
WITH OWNER
INTERIOR FINISH
WINDOW PER SCHEDULE
HARDIE SIDING
TYPICAL WINDOW JAMB DETAIL
Scale: 3" = 1'-0"4
NOTE: WINDOW AND DOOR DETAILS PROVIDED FOR TRIM
PROFILES ONLY. SEE MANUFACTURE'S INSTALLATION
REQUIREMENTS AND INSTRUCTION FOR FLASHING AND
WATERPROOFING DETAILS.
TYPICAL WINDOW HEAD DETAIL
Scale: 3" = 1'-0"2
2x6 HARDIE HEAD TRIM
CAP FLASHING
5/4 AT 15 DEGREE ANGLE,
OVERHANG HARDIE TRIM
1/2"
WOOD HEADER
WINDOW PER SCHEDULE
INTERIOR FINISH
INTERIOR TRIM, VERIFY
WITH OWNER
NOTE: WINDOW AND DOOR DETAILS PROVIDED FOR TRIM
PROFILES ONLY. SEE MANUFACTURE'S INSTALLATION
REQUIREMENTS AND INSTRUCTION FOR FLASHING AND
WATERPROOFING DETAILS.
WINDOW PER SCHEDULE
5/4 HARDIE TRIM
WINDOW HORIZONTAL MULL DETAIL
Scale: 3" = 1'-0"6
INTERIOR TRIM, VERIFY
WITH OWNER
BLOCKING AS REQUIRED
2x6 FRAMING
WINDOW VERTICAL MULL DETAIL
Scale: 3" = 1'-0"5
4" 5/4 HARDIE TRIM
WINDOW PER SCHEDULE3"
NOTE: WINDOW AND DOOR DETAILS PROVIDED FOR TRIM
PROFILES ONLY. SEE MANUFACTURE'S INSTALLATION
REQUIREMENTS AND INSTRUCTION FOR FLASHING AND
WATERPROOFING DETAILS.
INTERIOR TRIM, VERIFY
WITH OWNER
Page 47
Section VII. Item #1.
A602
SHEET TITLE:
architecture + planning
PROJECT:
NEW COMMERCIAL
ADDRESS:
204 BLUFFTON RD,
BLUFFTON, SC 29910
PROJECT ID:
REVIEWED BY:
DRAWN BY:
T. MICHAELS
T. MCGILL
SCHEDULES
ISSUE / REVISION:
COPYRIGHT SM7 DESIGN LLC. ALL RIGHTS RESERVED
THIS DRAWING IS THE PROPERTY OF SM7 DESIGN LLC AND IS NOT TO
BE REPRODUCED IN WHOLE OR IN PART OR TO BE USED ON ANY
OTHER PROJECT. DRAWINGS SHALL BE RETURNED UPON REQUEST
DRAWING SCALES ARE PROVIDED FOR REFERENCE ONLY. DO NOT
SCALE DRAWINGS. ORIGINAL SHEET SIZE - 24"x36"
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
NOT FOR CONSTRUCTION
UNLESS SIGNED AND SEALED
SM7 DESIGN LLC
19 PROMENADE ST., STE 201
BLUFFTON SC 29910
3/4/2026 FINAL HD REVIEW
SUBMITTAL
WINDOW SCHEDULE
Scale: 1/4" = 1'-0"1
A
WINDOW IDENTIFICATION
WINDOW SCHEDULE NOTES
Nominal Size Window Style Shutters Openings
Mark QTY. O.A. Width O.A. Height Configuration Interior Exterior Win
Egress
Accessories Comments
A 2 4'0" 2'0" Awning - - FALSE
B 2 3'6" 9'0" Double Hung - - FALSE WINDOW WITH TRANSOM, REFER TO WINDOW ELEVATIONS
C 4 3'0" 7'6" Double Hung - - FALSE WINDOW WITH TRANSOM, REFER TO WINDOW ELEVATIONS
D 4 3'6" 6'3" Double Hung - - FALSE
F 7 2'6" 3'0" Awning - - FALSE
G 6 3'0" 6'0" Double Hung - - ---
WINDOW ID TAG
MARK (SEE SCHEDULE)
1. WINDOW SIZES SHOWN ARE NOMINAL OVERALL SIZES. CONTRACTOR SHALL VERIFY
FINAL ROUGH OPENING SIZES WITH SELECTED WINDOW MANUFACTURERS.
2. VERIFY WINDOW MANUFACTURER'S SPECIFICATIONS AND INSTALLITION DETAILS
PRIOR TO INSTALLING WINDOWS FOR FLASHING AND WATERPROOFING
REQUIREMENTS. MANUFACTURER'S DETAILS AND REQUIREMENTS SHALL SUPERCEDE
ANY NOTE OR DETAILS ON THESE DRAWINGS. CONTACT ARCHITECT IN WRITING WITH
ANY DISCREPENCIES THAT AFFECT THE OVERALL DESIGN OF THE PROJECT.
3. ALL WINDOWS SHALL BE IMPACT RATED OR THE CONTRACTOR SHALL PROVIDE
ALTERNATE IMPACT PROTECTION AS REQUIRED BY BUILDING CODES OR AHJ.
4. CONTRACTOR TO VERIFY THAT SELECTED WINDOWS MEET NATIONAL EGRESS
CODE FOR FIRE EVACUATION WHERE EGRESS WINDOWS ARE REQUIRED BY BUILDING
CODES OR AHJ.
WINDOW ELEVATIONS
A B
6'-6"
4'-0"
2'-0"
2'-0"6"
3'-6"
C
2'-0"6"
3'-0"
9'-0"
5'-0"
D
6'-3"
3'-6" 3'-0"
6'-0"
E
7'-6"
F
3'-0"
2'-6" 3'-0"
6'-0"
G
WINDOW SCHEDULE
Mark Qty. Nominal Size Door Style Fire Rating
Width Height Thickness Configuration Slab Style Lights
Side
Wid
L Sidelt
Wid
R Sidelt
Frame Slab
Door
HW Set Accessories Comments
101 1 6'0" 10'6" 1 3/4" Swing Bi-part Glass N/A N/A DHW-#
102 1 3'0" 8'0" 1 3/4" Swing Simple Panel N/A N/A DHW-#
103 1 3'0" 8'0" 1 3/4" Swing Simple Glass N/A N/A DHW-#
201 2 6'0" 8'0" 1 3/4" Swing Bi-part Glass N/A N/A DHW-#
202 1 3'0" 8'0" 1 3/4" Swing Simple Glass N/A N/A DHW-#
203 1 3'0" 8'0" 1 3/4" Swing Simple Glass N/A N/A DHW-#
301 2 6'0" 8'0" 1 3/4" Swing Bi-part Glass N/A N/A DHW-#
101 201
301
102 103 202 203
204
302
7'-11" 2'-1"6"
3'-0" 3'-0"
10'-6"
6'-0"
8'-0"
3'-0"
8'-0"
3'-0"
8'-0"
3'-0" 3'-0"
6'-0"
8'-0"
3'-0"
8'-0"
3'-0"
Page 48
Section VII. Item #1.
Walls / Columns
Old Georgetown
Material: Brick
Color Selections
Project: 204 Bluff ton Road
Siding
Oyster White (SW 7637)
Material: Cementicious
Windows / Doors
Kolbe Forgent Series - Midnight
Material: Glastra
Trim / Cornice / Columnns
Shell White (SW 8917)
Material: Wood / Compos-
Railings / Balusters / Handrails
Black
Material: Powder Coated Aluminum
Porch Ceilings
Front Porch (SW 7651)
Material: Cementicious
Roof
Shingles - Moire Black
Metal - Pre-Weatherd Galvalume
Exhibit C
Page 49
Section VII. Item #1.
FORGENT ® SERIES
Exhibit E
Page 50
Section VII. Item #1.
We’re for people
who take building
to new levels.
We’re for people who are passionate about design,
who care about the big picture and the smallest
detail. We’re for people who aren’t satisfied with
mainstream choices... who push the limits of what’s
possible with the options and innovations that
can only be found in Kolbe® windows and doors.
We’re for a tradition of excellence that outlasts the
latest design trend. The Kolbe story began with a family
and a vision. Nearly 80 years after the Kolbe brothers
began their commitment to producing premium quality
windows and doors, products bearing their family
name can be found in some of North America’s most
impressive homes and businesses.
We’re for people who won’t settle for “standard.” We’re
for limitless options and custom solutions that can only
be found in Kolbe’s made-to-order products. Our team
members are craftspeople who focus on building one
window or door at a time, to create distinctive products
that fulfill your unique vision.
We’re for quality craftsmanship.
We’re for possibilities.
Let us bring
your vision
to life.
We’re for innovation.
We’re for people who want to take building to new
levels, with advancements in not only extraordinary
sizes and shapes, but also ground-breaking
products. We’re for creative thinking that redefines
what’s possible, constantly reimagining our
windows and doors to elevate style,
performance and functionality.
We’re for expertise.
We’re for people who dream of a personalized design
experience. That’s why you can’t find Kolbe windows
and doors in the aisles of a home center. Our products
are only available through a Kolbe dealer, because
they are as passionate about windows and doors as
you are about bringing your vision to life. And they will
work with you to make your dream a concrete reality.
© Kim Smith
Neme Studio | Dooling Design-Build
César Béjar Studio
© Bailey Chastang Photography
© The Studio
© The Studio
Page 51
Section VII. Item #1.
TABLE OF CONTENTS
The Forgent Series ...............................................1-8
Innovation &
Technology .............................. 3-4
Style & Design Options .................................. 5-6
Casements
............................................................ 7-8
Awnings ............................................................... 9-10
Double Hungs ..................................................11-12
Sliding Windows ..............................................13-14
Specialty Windows ..........................................15-19
Direct Sets .........................................................16
Radius Direct
Sets............................................17
Geometric Direct Sets.................................... 18
Complementary
Doors ................................ 20-23
Sliding ............................................................... 21
Multi-slide ........................................................
22
Professional Tools ................................................ 24
Neme Studio | Dooling Design-Build | César Béjar Studio© The Studio
Project Credit: Tommy Everson Architect | Jason Briles | Bennett Bossert
Near & Streeter Custom Homes | Peter VonDeLinde Photography
Page 52
Section VII. Item #1.
THE FORGENT ® SERIES
Forgent Series windows and doors incorporate innovative design and state-of-the-art technology
with a proprietary Glastra ® material. Engineered for strength, resilience, and ease-of-installation,
this high-performance product line is a perfect choice for new construction or replacement projects.
Forgent Series 1
© The Studio
Page 53
Section VII. Item #1.
Forgent Series 2
STRENGTH & PERFORMANCE:
• Strong and resilient Glastra® exterior with Glastra or Wood interior
• Advanced ladder design with multiple chambers for strength and energy efficiency
• Welded sash and frame with AccuForge® technology for a smooth, air and watertight seam
• Integral nailing fin has fewer sealing points, for rigidity and a watertight installation
• Impact performance capabilities to meet the demands of coastal hurricane zones
EASE OF INSTALLATION:
• Three convenient installation methods: integral nailing fin, installation clips, screw through frame
• Glazing bead receptor helps create a clean break-point during painting and staining
• Accessory groove allows for quick installation of exterior accessories without additional clips
• Dry glazed sash allows for serviceable sash and components
LADDER DESIGN &
INSTALLATION CLIP
GROOVES
GLAZING BEAD RECEPTOR
STEPPED FRAMEFLUSH FRAME
OPTION
INTEGRAL NAILING FIN
& ACCESSORY GROOVE
WELDED SASH & FRAME
WITH ACCUFORGE
The Forgent Series provides:
© The Studio© The Studio
Page 54
Section VII. Item #1.
Forgent Series 3
INNOVATION & TECHNOLOGY
Glastra is an innovative, recyclable material that helps form the resilient foundation of Forgent Series products.
Manufacturing byproducts are repurposed for use in other industries, such as underground industrial piping.
GLASTRA EXTERIOR
WITH WOOD INTERIOR
GLASTRA EXTERIOR
WITH GLASTRA INTERIOR
Forgent Series products are comprised of Glastra ®, a proprietary hybrid of fiberglass and UV stable polymer. To
better match décor and performance requirements, a Glastra exterior with a choice of Glastra or Wood interior
is available in select colors and finishes.
MATERIAL
Forgent Series windows are constructed of multi-
chambered Glastra extrusions in an advanced
ladder design for numerous benefits – the chambers
add strength and promote energy efficiency. The
same structural framework is used for All Glastra and
Glastra/Wood products, for consistent performance.
Both the exterior and interior are comprised of
Glastra, with finishes available in Cloud, Sahara,
Midnight or Bronze.
The exterior is comprised of Glastra, while the interior
is Pine wood, available in popular pre-finishes including:
Double Clear Coat, Latex Primer, Black Paint, White
Paint, or a variety of stains.
CONSTRUCTION
FORGENT SERIES
CONSTRUCTION
TYPICAL FIBERGLASS
CONSTRUCTION
shown
in photo
above
© Photo courtesy of Next Polymers Ltd./Brunet Group
Page 55
Section VII. Item #1.
Forgent Series 4
COMPRESSION SEAL
Forgent Series windows and doors feature EPDM gaskets in the glazing system as well as between the operable sash
and frame, to seal the joint and create an air and watertight seal. Similar to those used on commercial windows, cars
and airplane doors, they also keep noise out, for a quieter, more comfortable environment.
A Midnight, Bronze or Tungsten film can be applied
to Forgent Series products with a Glastra exterior
and interior. This film utilizes a pigmented acrylic
base technology that reduces heat absorption
and resists fading. A profile lamination process
permanently bonds the film to the Glastra
material, enabling it to withstand the harshest
of conditions – from extreme heat to extreme
cold. And because the film has a very low surface
tension, typical dirt, debris – even paint – can be
removed from the surface with mild soap and
water.
ACRYLIC FILM
AccuForge® is a registered trademark of Kolbe & Kolbe Millwork Co., Inc.
*Specialty windows (geometric and radius) and sliding doors are not manufactured with AccuForge technology.
Forgent Series exterior films are compliant with and have achieved 307-16 certification from the American
Architectural Manufacturers Association (AAMA). The AAMA 307-16 designation specifically refers to Voluntary
Specifications for Laminates Intended for Use on AAMA Certified Profiles.
Forgent Series window frames * and sash feature
AccuForge®, an innovative miter joint technology.
This state-of-the-art nip welding process creates
a stronger air and watertight seam with a smooth,
high-end finish. See AccuForge in action at:
kolbewindows.com/product-lines/forgent-series
ACCUFORGE®
Vinyl
Cellular PVC
Glastra
Aluminum
Pine
0 5 10 15 20 25 30 35 40 45
Thermal Expansion (In/In F˚ x 10-6)
All materials are subject to some level of
expansion as temperatures fluctuate. Forgent
Series Glastra material is less affected by
these changes, with a lower expansion rate
than many composite products, and less than
half the rate of vinyl products.
THERMAL EXPANSION
© Kim Smith Photo
TRANSPARENT
ACRYLIC
PIGMENTED
ACRYLIC BASE
WITH SOLAR SHIELD
TECHNOLOGY
PRINTING
INK
PRIMER
TRANSPARENT PVDF
(Fade Resistant)
Page 56
Section VII. Item #1.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
Kolbe offers distinctive style and design options to make your spaces unique. For the ultimate in personalization,
choose from our numerous options, including hardware, glass, divided lites, screens, sills, exterior trim, and more
– plus custom solutions to help bring your unique vision to life.
© Spacecrafting Photography
© Tommy Everson Architect | Near & Streeter Custom Builder | VonDeLinde Photography
Forgent Series 5
STYLE & DESIGN OPTIONS
There is so much more to glass than visibility. It can
add to the aesthetic, enhance indoor comfort and
acoustics, or provide privacy, security, and impact
resistance. From smart coatings and smart glass
to Sound Transmission Class (STC) glass and EPDM
gaskets for high noise areas, Kolbe’s numerous
glazing options provide optimum energy efficiency,
beauty and performance.
Add architectural detail to windows and doors with
performance divided lites. Choose from various
widths and patterns to a custom design that
accentuates the character and appearance of your
home. Or choose grilles-in-the-airspace for a similar
aesthetic with reduced cleaning time.
Kolbe offers numerous hardware styles and finishes
to complete your project. Complement your décor
or add the finishing touch to a casement and awning
combination or a new sliding door. Plus, the added
functionality of multi-point locks and automation
options on select products adds security and
convenience to your living experience.
GLASS
DIVIDED LITES
HARDWARE
Page 57
Section VII. Item #1.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
Some options for our products may have limited color offerings or may incur a nominal charge. Check with your Kolbe dealer for further details on pricing and availability.
Stain colors are shown on pine. Since no two trees are identical, wood can be expected to differ both in color and graining. These factors will influence the stain’s final color.
Printed images of wood species and stain options will vary from actual product colors. Selections should be made based on color samples available from your Kolbe
dealer. Stain colors are shown on pine. A double coat clear finish is also offered. Since no two trees are identical, wood can be expected to differ both in color and
graining. These factors will influence the stain’s final color.
Color-matched interior paint is available through Sherwin-Williams in the United States and Canada.
The color formula for Kolbe’s interior paint finishes is in their National Account System.
* All units supplied with unfinished pine interiors must be finished in the field.
**Latex primer is not a final finish.
† White and Black are single coat interior paint finishes with some visible wood grain.
Forgent Series 6
LATEX
PRIMER**
DOUBLE
CLEAR COAT
UNFINISHED
PINE*
RED WHEAT LIGHT OAK 998WHEAT
BLACK†WHITE†
SPICED WALNUTSUNSET OAK
EBONY LIBRARY REDCOFFEE BEAN
CHESTNUT
CHERRY
FINISH OPTIONS
Forgent Series windows and doors feature a durable
and resilient Glastra® exterior. The Cloud and Sahara
colors are integral to the Glastra material, while
Bronze, Midnight and Tungsten can be applied in
various combinations, as shown.
Forgent Series Glastra/Wood windows and doors are
offered with a Pine interior. For units that are ready
to install upon delivery, Forgent Series windows and
doors can be prefinished on the interior with one
of the water-based stains or paints shown. Stained
units are given two coats of satin clear finish. Because
our interior finishes are water-based, low-VOC stains
and paints, you can rest assured you’ve made an
environmentally conscious decision.
EXTERIOR FINISHES
INTERIOR FINISHES
BRONZE TUNGSTENMIDNIGHTCLOUD SAHARA
NOTE: Tungsten is available as an exterior finish only.
Ask your Kolbe dealer for details.
COMBINATION OPTIONS
/C.cap/L.cap/O.cap/U.cap/D.cap
/C.cap/L.cap/O.cap/U.cap/D.cap
/S.cap/A.cap/H.cap/A.cap/R.cap/A.cap/B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap /M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap
/W.cap/O.cap/W.cap/O.cap/O.cap/D.cap/O.cap/D.cap
/S.cap/A.cap/H.cap/A.cap/R.cap/A.cap
/T.cap/U.cap/N.cap/G.cap/S.cap/T.cap/E.cap/N.cap
/B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap
/M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap
/S.cap/A.cap/H.cap/A.cap/R.cap/A.cap
/C.cap/L.cap/O.cap/U.cap/D.cap
/C.cap/L.cap/O.cap/U.cap/D.cap//B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap /C.cap/L.cap/O.cap/U.cap/D.cap//T.cap/U.cap/N.cap/G.cap/S.cap/T.cap/E.cap/N.cap/C.cap/L.cap/O.cap/U.cap/D.cap//M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap
/W.cap/O.cap/O.cap/D.cap//B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap/W.cap/O.cap/O.cap/D.cap//C.cap/L.cap/O.cap/U.cap/D.cap/W.cap/O.cap/O.cap/D.cap//S.cap/A.cap/H.cap/A.cap/R.cap/A.cap/W.cap/O.cap/O.cap/D.cap//T.cap/U.cap/N.cap/G.cap/S.cap/T.cap/E.cap/N.cap/W.cap/O.cap/O.cap/D.cap//M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap
/B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap//C.cap/L.cap/O.cap/U.cap/D.cap//B.cap/R.cap/O.cap/N.cap/Z.cap/E.cap/M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap//C.cap/L.cap/O.cap/U.cap/D.cap//M.cap/I.cap/D.cap/N.cap/I.cap/G.cap/H.cap/T.cap
Page 58
Section VII. Item #1.
CASEMENTS
The design and performance of Forgent ® Series casements are the features that make these
windows so popular. Casements open from the side to a 90-degree angle, allowing for maximum
ventilation up to 36-by-78 inches. Multi-point locking levers offer a convenient way to tightly secure
your windows from one locking location. Crank handles fold down when not in use to prevent
interference with window treatments.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
Forgent Series 7
© Spacecrafting Photography
Click to view more: kolbewindows.com/gallery
Be Inspired u
Page 59
Section VII. Item #1.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
` 4-9/16” jam depth (New Construction)
` Flush frame groove filler (New Construction - no extension jamb)
` Energy efficient, insulating Solar Low-E glass
` Dry glazed to the interior with beveled glazing bead
` Accessory grooves are integral to the extruded frames
for the easy addition of accessories
` Insect screen with BetterVue® fiberglass mesh
and Water Shed Technology™
` Crank-out nesting handle and multi-point traditional
locking levers are color matched to the interior
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening
` Box-to-box mullion
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Multiple trim accessories (shipped loose)
` Insect screen available with aluminum or
UltraVue® mesh
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Nesting handle & locking lever in a variety of finishes
` Ashlar handle in a variety of finishes
` Window Opening Control Device (WOCD)
` Coastal hardware package
` Impact performance
STANDARD FEATURES OPTIONS
(not all options are available on all casement types; custom options also available)
` 3-1/4” overall frame depth; no nailing fin and
pre-drilled for installation (Replacement)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` 4-1/16” overall frame depth; no nailing fin and
pre-drilled for installation (Replacement)
` Unfinished pine interior with no visible fasteners
or wood exposed to the exterior
` Latex primed interior*
` Interior prefinishing
` Wood glazing bead receptor
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
BetterVue®, UltraVue® and Water Shed Technology™ are registered trademarks of PHIFER INCORPORATED.
Limitations may apply. Please consult your local Kolbe dealer for more details.
CASEMENTS
CRANK-OUT | PICTURE | TRANSOM | PICTURE COMBINATION
MULLED CONFIGURATIONS
Forgent Series 8
InteriorExterior
GLASTRA/GLASTRA
CASEMENT
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 60
Section VII. Item #1.
© Bailey Chastang Photography
Forgent Series 9Project credits: Tommy Everson Architect | Jason Briles | Bennett Bossert
Near & Streeter Custom Builder | Peter VonDeLinde Photography
AWNINGS
Forgent Series awning windows open outward from the bottom, to allow generous airflow even
on rainy or misty days. Awnings offer unique style to any room and are the perfect complement to
other Kolbe® windows and doors – with maximum openings up to 5-by-5 feet. Crank-out nesting
handles, stylish Ashlar handles and dual-arm operators make these windows easy to open and
close. Crank-out handles fold down when not in use.
Be Inspired u
Click to view more: kolbewindows.com/gallery
Page 61
Section VII. Item #1.
InteriorExterior
GLASTRA/GLASTRA
AWNING
Ultra Series
Forgent Series 10
` 4-9/16” jam depth (New Construction)
` Flush frame groove filler (New Construction - no extension jamb)
` Energy efficient, insulating Solar Low-E glass
` Dry glazed to the interior with beveled glazing bead
` Accessory grooves are integral to the extruded frames
for the easy addition of accessories
` Insect screen with BetterVue® fiberglass mesh
and Water Shed Technology™
` Crank-out nesting handle and multi-point traditional
locking levers are color matched to the interior
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening
` Box-to-box mullion
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Multiple trim accessories (shipped loose)
` Insect screen available with aluminum or
UltraVue® mesh
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Nesting handle & locking lever in a variety of finishes
` Ashlar handle in a variety of finishes
` Coastal hardware package
` Impact performance
STANDARD FEATURES OPTIONS
(not all options are available on all casement types; custom options also available)
` 3-1/4” overall frame depth; no nailing fin and
pre-drilled for installation (Replacement)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` 4-1/16” overall frame depth; no nailing fin and
pre-drilled for installation (Replacement)
` Unfinished pine interior with no visible fasteners
or wood exposed to the exterior
` Latex primed interior*
` Interior prefinishing
` Wood glazing bead receptor
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
BetterVue®, UltraVue® and Water Shed Technology™ are registered trademarks of PHIFER INCORPORATED.
Limitations may apply. Please consult your local Kolbe dealer for more details.
AWNINGS
CRANK-OUT | PICTURE UNITS | PICTURE COMBINATION
MULLED CONFIGURATIONS
Tommy Everson Architect | City Homes | Spacecrafting Photography
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 62
Section VII. Item #1.
DOUBLE HUNGS
Blending seamlessly with traditional architecture, the Colonial American style sash operate easily
and tilt inward for convenient cleaning. Handles on both sash allow smooth opening and closing,
while a sloped sill helps guard against water damage. Replace older windows with cottage-style
units, and a choice of divided lites, hardware, screens, or triple pane glass – for enhanced style
and performance.
© Epic Shoots Photography
© Epic Shoots Photography
Forgent Series 11
Click to view more: kolbewindows.com/gallery
Be Inspired u
Page 63
Section VII. Item #1.
Photo courtesy of Stacy Zarin-Goldberg
Forgent Series 12
GLASTRA/WOOD
NEW CONSTRUCTION DOUBLE HUNG
` Flush frame groove filler (New Construction - no extension jamb)
` Energy efficient, insulating Solar Low-E glass
` Equal glass sizing provides matching sight lines
from sash to sash
` Dry glazed to the interior with beveled glazing bead
` Accessory grooves are integral to the extruded frames
for the easy addition of accessories
` Full frame insect screen with BetterVue® fiberglass mesh
and Water Shed Technology™
` Stainless steel, constant force balance system provides
durability and ease of operation
` Sash lock and tilt latches are color matched
to the interior
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening (New Construction)
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Fixed top sash
` Multiple trim accessories (shipped loose)
` Insect screen available with aluminum or
UltraVue® mesh
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Lift handle in various finishes to match hardware
` Window Opening Control Device (WOCD)
` Sash limiters for safety (non by-passable and does not meet
WOCD requirements)
` Cottage and reverse cottage style
` Impact performance
STANDARD FEATURES OPTIONS (custom options are also available)
` 3-1/4” overall frame depth (Replacement)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` Lift handle on bottom sash is color matched
to the interior
` 4-1/8” overall frame depth (Replacement)
` Unfinished pine interior with no visible fasteners
or wood exposed to the exterior
` Latex primed interior*
` Interior prefinishing
` Wood glazing bead receptor
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
BetterVue®, UltraVue® and Water Shed Technology™ are registered trademarks of PHIFER INCORPORATED.
Limitations may apply. Please consult your local Kolbe dealer for more details.
DOUBLE HUNGS
NEW CONSTRUCTION | REPLACEMENT
COTTAGE STYLE | REVERSE COTTAGE STYLE | STUDIO | TRANSOM
PICTURE COMBINATION UNITS | SEGMENT HEAD | HALF-CIRCLE TOP
InteriorExterior
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 64
Section VII. Item #1.
Forgent Series 13
SLIDING WINDOWS
Sliding windows provide space-saving solutions for expansive openings while offering solid
performance ratings. The design incorporates a Glastra ® exterior, a Glastra or pine interior, and
tilt-in sash for easy operation and cleaning. Forgent ® Series single and triple sliding windows are
best where space is at a premium, with maximum panel heights up to 72".
Be Inspired u
Click to view more: kolbewindows.com/gallery
Page 65
Section VII. Item #1.
Forgent Series 14
GLASTRA/GLASTRA
NEW CONSTRUCTION SLIDING WINDOW
` Flush frame groove filler (New Construction - no extension jamb)
` Available as Active-Fixed (AF) or Fixed-Active (FA)
` Energy efficient, insulating Solar Low-E glass
` Equal glass sizing provides matching sight lines
from sash to sash
` Dry glazed to the interior with beveled glazing bead
` Accessory grooves are integral to the extruded frames
for the easy addition of accessories
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening (New Construction)
` Full frame insect screen with BetterVue® fiberglass
mesh and Water Shed Technology™
` Nylon rollers for ease-of-operation
` Sash lock and tilt latches are color matched
to the interior
` Tilt latches placed at the top of the operable sash
for ergonomic removal
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Triple sliding 1
/4-1/2-1/4 and 1/3-1/3-1/3 splits
` Multiple trim accessories (shipped loose)
` Insect screen available with aluminum or
UltraVue® mesh
` Half screen
` Pull handle in various finishes to match hardware
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Window Opening Control Device (WOCD)
` Sash limiters for safety (non by-passable and does not meet
WOCD requirements)
` Impact performance
STANDARD FEATURES OPTIONS (custom options are also available)
` 3-1/4” overall frame depth (Replacement)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` Pull handle on active sash is color matched
to the interior
` 4-1/8” overall frame depth (Replacement)
` Unfinished pine interior with no visible fasteners
or wood exposed to the exterior
` Latex primed interior*
` Interior prefinishing
` Wood glazing bead receptor
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
BetterVue®, UltraVue® and Water Shed Technology™ are registered trademarks of PHIFER INCORPORATED.
Limitations may apply. Please consult your local Kolbe dealer for more details.
SLIDING WINDOWS
NEW CONSTRUCTION | REPLACEMENT
SINGLE | DOUBLE | TRIPLE | QUAD
InteriorExterior
Yellow Tree Construction | Scott Amundson Photography
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 66
Section VII. Item #1.
SPECIALTY WINDOWS
Forgent® Series specialty windows are available in varied sizes and styles. Direct sets are ideal for
maximizing daylight when venting is not required. The glass is set directly into the frame, allowing a
larger opening for passive lighting and views. Radius windows can stack over other Kolbe® windows
and doors to create gracious curves and allow more light to enter. Geometrics can create a focal
point, accentuate the architectural design, or comprise a window wall with angled shapes.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
Forgent Series 15
Click to view more: kolbewindows.com/gallery
Be Inspired u
Page 67
Section VII. Item #1.
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
Forgent Series 16
` Flush frame groove filler (New Construction - no extension jamb)
` Units designed to be mulled directly to other Forgent
Series products, either in the factory or in the field
` Energy efficient, insulating Solar Low-E glass
` Dry glazed to the interior with a beveled bead
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening
` Replacement direct sets in casement
and new construction double hung profiles
` Casement and double hung direct set profiles
available for a pleasing match
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Multiple trim accessories (shipped loose)
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Impact performance
STANDARD FEATURES OPTIONS (custom options are also available)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` Unfinished pine interior
` Latex primed interior*
` Interior prefinishing
` Square wood stops
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
DIRECT SETS
NEW CONSTRUCTION | REPLACEMENT
GLASTRA/GLASTRA
CASEMENT DIRECT SET
InteriorExterior
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 68
Section VII. Item #1.
Forgent Series 17
` Flush frame groove filler (New Construction - no extension jamb)
` Units designed to be mulled directly to other Forgent
Series products, either in the factory or in the field
` Energy efficient, insulating Solar Low-E glass
` Dry glazed to the interior with a beveled bead
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening
` Replacement direct sets in casement
and new construction double hung profiles
` Casement and double hung direct set profiles
available for a pleasing match
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Multiple trim accessories (shipped loose)
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Impact performance
` Custom shapes
STANDARD FEATURES OPTIONS (custom options are also available)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` Unfinished pine interior
` Latex primed interior*
` Interior prefinishing
` Square wood stops
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
RADIUS DIRECT SETS
QUARTER CIRCLE | HALF CIRCLE | FULL CIR CLE
SEGMENT | QUARTER SEGMENT | WITH OR WITHOUT LEGS
Exterior
GLASTRA/WOOD
CASEMENT DIRECT SET
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 69
Section VII. Item #1.
Forgent Series 18
` Flush frame groove filler (New Construction - no extension jamb)
` Units designed to be mulled directly to other Forgent
Series products, either in the factory or in the field
` Energy efficient, insulating Solar Low-E glass
` Dry glazed to the interior with a beveled bead
` Integral 1-1/4” nailing fin provides easier installation
and helps seal the window opening
` Replacement direct sets in casement
and new construction double hung profiles
` Casement and double hung direct set profiles
available for a pleasing match
` Exterior acrylic film in Midnight, Bronze or Tungsten
` Multiple trim accessories (shipped loose)
` Extension jambs available in depths up to 9” overall
` Offset extension jambs
` Stepped frame groove filler for drywall return
(no extension jamb)
` Galvanized steel installation clips
` Impact performance
` Custom shapes
STANDARD FEATURES OPTIONS (custom options are also available)
` Cloud or Sahara integral color
` Interior acrylic film in Midnight or Bronze
(only on units with Midnight or Bronze exterior)
` Unfinished pine interior
` Latex primed interior*
` Interior prefinishing
` Square wood stops
GLASTRA/WOOD (additional options specific to Wood interiors)
GLASTRA/GLASTRA (additional options specific to Glastra interiors)
* Latex primer is not a final finish.
NOTES: All measurements are nominal.
GEOMETRIC DIRECT SETS
PENTOID | PARALLELOGRAM | TRAPEZOID | RIGHT TRIANGLE | ISOSCELES
TRIANGLE | CLIPPED CORNER | DOUBLE CLIPPED CORNER | OCTAGON
InteriorExterior
© Spacecrafting Photography | Denali Custom Homes | Redstone Interiors
GLASTRA/WOOD
CASEMENT DIRECT SET
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 70
Section VII. Item #1.
*Full Circle is only available in All Glastra.
Segment
Quarter
Circle
Pentoid Clipped Corner
Segment
w/o legs
Quarter Circle
w/o legs
Full Circle*
TrapezoidParallelogram
Double Clipped
Corner
Quarter
Segment
Half Circle
Right Triangle
Octagon
Quarter Segment
w/o legs
Half Circle
w/o legs
Isosceles Triangle
SPECIALTY WINDOW SHAPES
Forgent Series 19
Page 71
Section VII. Item #1.
COMPLEMENTARY DOORS
Kolbe offers a selection of sliding, multi-slide and swinging doors from our other product lines to
complement the Forgent® Series windows used in your design. Mix and match the distinct styles,
characteristics and expanded options to achieve your desired aesthetic. The same coordinated
lead times will help builders get all of the products needed to complete their project.
© Spacecrafting Photography
Forgent Series 20
Click to view more: kolbewindows.com/gallery
Be Inspired u
Page 72
Section VII. Item #1.
NOTE: All measurements are nominal.
Centor® is a registered trademark of Centor Design Pty Ltd.
BetterVue® and Water Shed Technology™ are registered trademarks of PHIFER INCORPORATED.
AutoSlide™ is a registered trademark of AutoSlide LLC.
Limitations may apply. Please consult your local Kolbe dealer for more details.
Forgent Series 21
` Cloud or Sahara interior and exterior color
` Standard jamb width is 5-15/16” (4-9/16” behind the nailing fin)
` Energy efficient, tempered Solar Low-E glass
` Dry glazed to the interior
` Accessory grooves are integral to the extruded frames
for easy addition of acces
sories
` Frame setup for 2-wide doors
` Equal glass sizing provides matching sight lines
from panel to panel
` Steel panel reinforcement for rigidity
` Stainless steel panel rollers
` Allure dual-point handle set in White
` Low-profile, aluminum-capped self-draining sill
in Bronze anodized
` Exterior in Midnight, Bronze or Tungsten color
` Interior in Midnight or Bronze color
(only on units with Midnight or Bronze exterior)
` Allure dual-point handle set in Clay
` Multi-point locking handle sets with arch and bell
escutcheons in various finishes
` Signature handle set in a variety of finishes
` Contemporary Square handle set in a variety of finishes
` Secondary security lock (foot bolt)
` Insect screen with BetterVue® fiberglass mesh
and Water Shed Technology™ in extruded
aluminum frame
` Insect screen with UltraVue® fiberglass mesh
or aluminum mesh
` Centor® retractable interior screens and shades
in select sizes, configuratio
ns and colors
` Galvanized steel installation clips
` Three-point lock mechanism
` AutoSlide™ automation options with four modes:
Automatic, Hold Open, Lock, Pet
` Impact performance
STANDARD FEATURES OPTIONS (custom options are also available)
3-Wide Unit
` Operation = Active-Fixed-Fixed (AFF)
or Fixed/Fixed/Active (FFA)
4-Wide Unit
` Operation = Fixed-Active-Active-Fixed (FAAF)
OPERATIONAL OPTIONS
2-PANEL | 3-PANEL | 4-PANEL | TRANSOMS
COMPLEMENTARY
SLIDING DOORS
Neme Studio | Dooling Design-Build | César Béjar Studio
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 73
Section VII. Item #1.
Forgent Series 22
NOTES: All measurements are nominal.
Centor® is a registered trademark of Centor Design Pty Ltd.
AutoSlide™ is a registered trademark of AutoSlide LLC.
Limitations may apply. Please consult your local Kolbe dealer for more details.
` Cloud or Sahara interior and exterior color
` 3- or 6-panel stacking configurations
` Energy efficient, tempered Solar Low-E glass
` Frame shipped knocked down, prepped for assembly
` Contemporary Square handle set with dual-point
lock in White
` Bronze anodized aluminum-capped, self-draining sill
` Exterior in Midnight, Bronze or Tungsten color
` Interior in Midnight or Bronze color
` Galvanized steel installation clips
` Retractable insect screen in White or Black
` Centor® retractable interior screens and shades
in select sizes, configuratio
ns and colors
` Contemporary Square handle set with dual-point lock
in additional finishes
` AutoSlide™ automation options with four modes:
Automatic, Hold Open, Lock, Pet
` HVHZ impact performance (3-panel only)
STANDARD FEATURES OPTIONS (custom options are also available)
3-Wide Unit
` Active-Active-Fixed (AAF)
Fixed-Active-Active (FAA)
6-
Wide Unit
` Fixed-Active-Active-Active-Active-Fixed (FAAAAF)
OPERATIONAL OPTIONS
3-PANEL | 6-PANEL
COMPLEMENTARY
MULTI-SLIDE DOORS
View Style Options & Technical Data u
(Click to view hardware, glass, divided lites, finishes, and
more, as well as performance and specification details.)
Page 74
Section VII. Item #1.
SLIDING | MULTI-SLIDE | SWINGING
ADDITIONAL DOORS
See how Kolbe’s versatile product lines can
help complete your Forgent® Series project.
Forgent Series 23
Heritage Series
Perfect for restoration projects, these all-wood doors are designed for
architectural and historical authenticity. Complement Forgent Series windows
with stained wood interiors and high-performance K-Kron II coated exteriors.
Ultra Series
Designed for versatility, durability & performance, these wood-and-aluminum-
clad doors are ideal for traditional to modern architectural styles. The ability
to match design details and colors with a palette of long-lasting, vibrant hues
– plus custom blends – allows them to coordinate with any aesthetic.
SLIDING DOORS | SWINGING DOORS
SLIDING DOORS | MUL
TI-SLIDE DOORS | SWINGING DOORS
© Zack Benson
SLIDING DOORS | MULTI-SLIDE DOORS | SWINGING DOORS MULTI- SLIDE DOORS (SP68) | SWINGING DOORS (ML8)
VistaLuxe® WD LINE VistaLuxe® AL LINE
VistaLuxe® Collection
Complement your Forgent Series
project with clean lines and large
expanses of glass. Choose from
the VistaLuxe® WD LINE’s warm
wood interiors with extruded
aluminum exteriors, or thermally
broken, all-aluminum VistaLuxe®
AL LINE doors for contemporary
style and functionality.
© Jeeheon Cho
© Keen Eye Marketing
Learn More u
Learn More u
Learn More u
Learn More u
Page 75
Section VII. Item #1.
PROFESSIONAL TOOLS
Kolbe prides itself on offering the tools and resources architects, builders and other industry professionals need to
complete their projects. From product specifications and 3D models to continuing education courses and webinars,
Kolbe supports all of your project needs.
Project credits: Tommy Everson Architect | Jason Briles | Bennett Bossert
Near & Streeter Custom Homes | Peter VonDeLinde Photography
VIRTUAL SHOWROOMS
Experience Kolbe's full capabilities through three
interactive showrooms filled with product displays
and custom solutions.
AIA/CES COURSES
As a Registered AIA Continuing Education Services (CES)
provider, Kolbe provides AIA Learning Units (LU) and/or Health,
Safety & Welfare (HSW) credits as required per state and/or
professional memberships to meet yearly requirements.
• Door configurations
• Clear openings
• Care & maintenance guide
• Acoustic data
• Energy performance
• Performance class & grade
• Product brochures
• Color & design samples
• Warranties
ADDITIONAL RESOURCES INCLUDE:
• Cross section drawings
• Elevation charts
• 3D Revit® models
• CSI specifications
• Installation instructions
ARCHITECT LIBRARY
Kolbe’s Architect Library is the main resource
for specifying VistaLuxe WD LINE windows and
doors. Search detailed product information
and technical data, including:
INSPIRATION GALLERY
Browse through photos, videos, project profiles
and custom solutions.
kolbewindows.com/gallery
kolbewindows.com/virtual-showroom
Forgent Series 24
Explore Professional Tools u
Navigate the Virtual Showrooms u
Browse the Inspiration Gallery u
Page 76
Section VII. Item #1.
www.kolbewindows.com
1323 S. 11th Avenue | Wausau, WI 54401-5998
715.842.5666
© 2025 Kolbe & Kolbe Millwork Co., Inc. Kolbe & Kolbe Millwork Co., Inc. reserves the right to change specifications without notice.
The photography featured herein does not necessarily imply an endorsement of Kolbe products by the property owners.
Photography used may not represent current Kolbe product features and options.
Front cover photo © Scott Gilbertson Photography | Back cover photo © Peter Vance /The Studio
Forgent Series Brochure_0925_DIG
Page 77
Section VII. Item #1.
CALHOUN STREET PROMENADE OWNERS’ ASSOCIATION
ARCHITECTURAL COMMITTEE
204 Bluffton Road
Bluffton, SC 29910
Date: March 25, 2026
RE: Architectural Approval – New Construction
Dear Homeowner,
The Calhoun Street Promenade Owners Association Architectural Committee has
reviewed your submitted plans and is pleased to inform you that your application for a
new build has been approved as of November 14, 2025.
This approval is based on the plans and specifications provided and is granted with the
understanding that all construction will be completed in accordance with the
Association’s governing documents, architectural guidelines, and all applicable local
building codes and regulations.
Any changes or deviations from the approved plans must be resubmitted to the
Architectural Committee for review and approval prior to implementation.
We wish you success with your project and appreciate your cooperation in maintaining
the community's quality and integrity.
Sincerely,
Architectural Committee
Calhoun Street Promenade Owners Association
Page 78
Section VII. Item #1.
M E M O R A N D U M
TO: Historic Preservation Commissioners
FROM: Town of Bluffton Growth Management Staff
RE: Site Feature Permits from February 17, 2026, to April 16, 2026
DATE: May 1, 2026
SUMMARY: Town Staff will be updating the Historic Preservation Commission (HPC) monthly on all site
feature permits that have been applied for, approved, denied, withdrawn, put on hold, or issued. These
permits are reviewed at Staff level.
Address Description of Application Staff Status
5718 Guildford Place Residential Fence Caroline Luke Approved
82 Boundary St Repairs to building Glen Umberger Approved
132 Bridge St Residential water heater Caroline Luke Approved
45 Calhoun St Sign: Howard Hannah Allen Real
Estate
Caroline Luke Approved
101 Calhoun St Temporary Ramp Glen Umberger Approved
89 Bridge St Sign: The Bluffton Bookshop & The
Frozen Fiddler
Caroline Luke Approved
34 Bridge St Residential Fence Glen Umberger Approved
30 Promenade St Unit A Sign: Ofilia Caroline Luke Approved
6 Promenade St Unit
1028
Deck Extension Caroline Luke Approved
Page 79
Section VIII. Item #1.
Source: Town of Bluffton website. First collected Nov 7, 2026.